An innovative rack power distribution ready for IT room evolutions
|
|
|
- Barnard Holland
- 10 years ago
- Views:
Transcription
1 ibusway for Data Center An innovative rack power distribution ready for IT room evolutions Based on a monitored busway system that combines high availability and energy efficiency Dong Yi
2 Reminder on data center 2
3 Data Center main mission Globally speaking a Data Center has one main mission: Supplying data processing and storage capacity to continuously operate business guarantying optimum up-time and energy efficiency, in a perfectly secure manner...while keeping in control the environmental long term impact 3
4 Data center customer expectations Improving power availability Maximum energy efficiency Forecast growth in Data Center power consumption in the USA and Europe (* EU-15 + Switzerland). 4
5 Data center customer expectations Maximum flexibility Maximum speed of deployment Data centers activity involves IT equipment that is constantly changing. The installation must be designed so as to: satisfy the increasing needs in electrical power from new generations of servers. allow flexibility and upgradability without altering the data center operations. Optimized Capex and Opex TOC (Total Cost of Ownership) Equipment acquisition cost (CapEx - Capital Expenditure) Operating and maintenance costs (OpEx Operating Expenditure) 5
6 ibusway for Data Center 6
7 ibusway for Data Center is a part of a global solution ibusway for Data Center 7
8 Communication bus Maintenance room Supervision in IT room Supervision room on site Busbar trunking Plug-in tap-units Main switchboard Remote supervision room Busbar trunking Busbar trunking 8
9 ibusway for Data Center is A final distribution for servers and IT equipment 1 Based on prefabricated Canalis KS range busbar trunking systems and specific support for Data Center Global management system ION Enterprise, ISX central, etc 5 A flexible and monitored distribution to match the equipment renewal rate with 2 A variety of plug-in units with built-in current energy metering for low to high density IT environment 3 Metering at LVHQ switchboard (Current, THD,etc ) A local HMI : touch screen for electrical data at fingertips An open communication capability to higher level management systems (power, energy, breaker status) A system ready to a speed deployment along with a portfolio of services: Up-stream support: architecture design (software) Operational service: commissioning Tested and warranty by Schneider Electric
10 The solution is more than busway Monitoring power and energy, circuit-breakers status and localization Sub billing 10
11 Monitoring solution based on new Schneider Electric offer New NSX circuit-breakers HMI in each IT room energy efficiency programs, kwh cost allocation/invoicing capacity management, reduced mistakes risk hence increased availability easier operation Innovative communication New EN40 Kilowatt-hour meters flexibility, openness with global data measurement system for IT room IT staff or facilities personnel can add and remove plug-in units at any point along the busway without shutting down the main busway system. 11
12 Alert and localization 12
13 Metering by line and rack PDU You have a clear view of capacity available for new servers. Define consumption reduction actions. Accurately allocate and charge the energy costs for each server. 13
14 Historic of the previous alarms Allows you to diagnose faults and take action rapidly without shutting down operations. 14
15 The solution takes into account the redundancy principle NSX circuit-breakers NSX circuit-breakers Canalis busway IT equipment Canalis tap-off units 15
16 Modular solution for a duplicable design Room Management Unit Zone Management Units NSX System A A PLC M340 System B B F ² Racks C E D Busway Lines ASi cables Plug-in 16 Tap-off Units
17 A modular offer Global management system by Schneider Electric (ION Enterprise, ISX central) or other Full pack Room supervision & tap-off units configuration on Magelis Advanced pack Classic pack Power distribution to racks by Canalis Measure of racks energy, power rate and circuit breaker status Data available on Twido 17
18 With the best in class Schneider Electric products Power distribution to the rack Canalis KS (Length & feed unit) Canalis KS Plug In unit MCB, Vigi, Auxiliary MCCB Compact NSX Measure to the rack Energy meter (EN40, PM9-P) AS-interface (4I Module, bus) TWIDO PLC & power supply Micro logic (Compact NSX) & connection Room supervision Power supply PLC M340 HMI Magelis Enclosure 18
19 The solution is ready for implementation Tap-off units are supplied pre-wired The field bus can be connected everywhere Installation of the new rack Step by step instructions allow a simple configuration Tap-off units are installed power on Monitoring devices are easily set-up The new rack is rapidly powered and monitored 19
20 ibusway for Data Center key benefits 20
21 3 different architectures for racks power distribution by cables Main PDU LV switchboard Main PDU integrated in rack LV switchboard modular by busway LV switchboard Protection in switchboard (main PDU) Protection in modular PDU Protection in plug-in tapoff units 21
22 Availability is drastically increased Busway The decentralized electrical distribution architecture based on Busway is much more reliable than the traditional centralized solution based on cables and PDU. This result comes mainly from the architecture and not from the reliability difference between busway and cables. Busway Unavailability: 10,28 hours / years Cables PDU + cables unavailability: 16,74 hours / year This graph shows the yearly unavailability for a Tier II architecture. These results are from a complete study of all data center architecture. This study is available for consultation 22
23 A safe & simple solution compare to the legacy cable Main LV switchboard + cables Main LV switchboard + Busway Tap-off units can be plugged in or removed without shutting down the system, ensuring maximum continuity of service when the racks are added or moved ibusway for Data Center makes electric circuits clear and easy to understand for fast servicing where needed Zero foot print : busway can be installed overhead or raised floor 23
24 Decentralized distribution reduces the risks of human error Legibility of distribution : Electrical architecture components are easy to locate and to identify Servicing in front of the cabinet without walking to a remote location power distribution unit to turn off the circuit to the cabinet, risking the human error of shutting off the wrong circuit. Canalis are maintenance free thanks to sliding contact made of silver platted copper 1 spring of the tap-off clamp 2 copper zone of the clamp 3 silver-plated copper zone 4 conductor silver- plated copper ridder 24
25 The solution brings you flexibility 1 st year installation (40%) 2 years later (100%) You can upgrade your installation during lifetime To buy only what you need To optimize your TCO To increase the power of an existing IT room A system ready to a speed of deployment Reducing installation time on site Busway and tap-off units are plug and play to reduce the work 25
26 Thanks to decentralized distribution the copper losses are reduced Cables Busway 26
27 No hazardous substances in ibusway for Data Center components All Canalis Busway components are halogen free as standard (no PVC) Conductors are air insulated Housing is made of steel Plastic parts are mainly made of PA ( polyamide) Canalis Busway is designed in compliance with the RoHs European recommendation 27
28 ibusway for Data Center has a long lifecycle and can be easily recycled Old circuits cables become a waste in 95% of cases Canalis Busway is designed for a long service life and can easily be dismantled, cleaned and reused First 1956 installation is still in use More than 30 years old installations in the European car industry still in use All components of our products are stamped to show their material to make recycling easier All materials used in our packing can be recycled 28
29 ibusway for Data Center key benefits 1/2 Availability Thanks to the decentralized distribution the power availability is increased by a factor 1,6 compare to low voltage switchboard & cable distribution The monitoring of the branch circuit load enables to anticipate potential tripping The default localization reduce the servicing time Energy efficiency The solution measures the energy of the racks and enables to analyze and to envisage actions to optimize energy The small size of the busway compare to cable improves raised floor cooling Thanks to the decentralized distribution the copper losses are reduced Contribute to sustainable development No hazardous substance Clean, reusable and fully recyclable 29
30 ibusway for Data Center key benefits 2/2 Flexibility Tap-off units are plug and play power on The monitoring system can be set up directly by the electrical team in the IT room Speed of deployment Thanks to modular system, basic architectures can be copied and adapted to each size, shape and data center s uses Tap-off unit are pre-wired and pre-tested in workshop Busway and tap-off units are plug and play to reduce the work on site The monitoring system is ready to use Total Cost of Ownership (TCO) Optimized investment and maintenance costs reduced the TCO by 5 to 10% vs Low Voltage switchboard & cable Enable capacity management and sub-billing 30
31 ibusway for Data Center references 31
32 Banco Commercial Portugues Portugal BSCH Ciudad Financiera (Spain) Experian, Colocation/Hosting, UK Bahrti, Noida and Pune data centers, Telecoms, India Colt telecom & internet provider France, Belgium Digiplex Colocation facility Sweden Eurocontrol air navigation controler Belgium IBM head quater Spain, Italy MCI-Worldcom telecom & internet provider United Kingdom, Italy Interxion Colocation Spain, Belgium Telecity UK Station switch - Belgium Fujitsu Netherlands Pink Roccade SSII IT services -Netherlands Iliad telecom & internet provider - France Reuters World wild new- Switzerland Euroclear transaction bank Belgium ST MicroElectronics semiconductor manufacturer France Kuusitunturi - Finland DHL European Datacenter - Czech Republic Peugeot Car manufacturer France Belgacom telecom & internet provider Belgium Safehost colocation-switzerland EuroBank- Greece Française Des Jeux - France 32
S c h n e i d e r E l e c t r i c BUSINESS IMPACT. Jack Hack Enterprise System Engineer 19 November 2015
S c h n e i d e r E l e c t r i c BUSINESS IMPACT Datacenter means business - create the bridge between IT en Facilities. Jack Hack Enterprise System Engineer 19 November 2015 1 Your ability to compete
CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers
CEMEP UPS The high environmental performance solution for power supply to high-availability data centers Exchanges of information and communication needs are growing at an exponential rate. That growth
A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture
A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture By Neil Rasmussen White Paper #129 Executive Summary Significant improvements in efficiency, power density, power monitoring,
Power Distribution in Data Centers: STARLINE Track Busway, PX ipdus and Power IQ
Power Distribution in Data Centers: STARLINE Track Busway, PX ipdus and Power IQ 2011 Raritan Inc. Overview Data center managers are faced with increasingly challenging demands: supplying additional computing
RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE
RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE Highly efficient solutions for power distribution, management and monitoring POWER DISTRIBUTION WIRE-FREE MONITORING LEAK DETECTION Daxten provides comprehensive
A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture
A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture White Paper 129 Revision 1 by Neil Rasmussen > Executive summary Significant improvements in efficiency, power density,
Data center solutions Medium & large enterprise, multi-tenant and hyperscale. Energize your data center, maximize the value of your investment
Data center solutions Medium & large enterprise, multi-tenant and hyperscale Energize your data center, maximize the value of your investment We serve the needs of data centers of all sizes, around the
Types of Electrical Meters in Data Centers
Types of Electrical Meters in Data Centers White Paper 172 Revision 1 by David Kidd and Wendy Torell > Executive summary There are several different types of meters that can be designed into a data center,
Tel.X Ni-Cd battery. The compact maintenance-free solution for telecom networks
Tel.X Ni-Cd battery The compact maintenance-free solution for telecom networks Tel.X, delivering high-energy performance in a compact maintenance-free package Tel.X: guaranteed power continuity for remote
Data Center Uninterrupted efficiency, guaranteed reliability and continuous modularity. ABB solutions always work.
Data Center Uninterrupted efficiency, guaranteed reliability and continuous modularity. ABB solutions always work. Data security is first of all electrical Maximizing security while providing efficiency
World s Greenest High Performance Data Center
World s Greenest High Performance Data Center EcoDataCenter Sustainability for future generations Our Services Colocation Data Center for Mission Critical Requirements Lockable racks, cages, private rooms
Premium Data Centre Europe - 2012 Pricing, Business Model & Services
Premium Data Centre Europe - 2012 Pricing, Business Models & Services Premium Data Centre Europe - 2012 Pricing, Business Model & Services Table of Contents A list of figures used in this report 5 Methodology
Yam Hong 施 耐 德 電 機 亞 太 日 本 區 (APJ) 三 相 關 鍵 電 源 市 場 開 發 經 理. Schneider Electric - Division - Name Date
Yam Hong 施 耐 德 電 機 亞 太 日 本 區 (APJ) 三 相 關 鍵 電 源 市 場 開 發 經 理 1 Agenda 1 2 3 相 UPS 總 覽 Introduction & Overview of 3 Phase UPS 理 解 客 戶 最 大 的 考 量 點 Understanding Top Customer Concerns 3 Galaxy VM 關 鍵 技 術 創
Simplifying Data Center Design/Build
Simplifying Data Center Design/Build A new approach to deliver speed, cost, and performance (availability, efficiency, scalability) Eduard Bodor Data Center Business Development Manager for Central and
Power Distribution Considerations for Data Center Racks
Power Distribution Considerations for Data Center Racks Power Distribution Considerations for Data Center Racks Table of Contents 3 Overview 4 At what voltage do you run all the IT equipment? 4 What electrical
Ralf Christian, CEO Low and Medium Voltage. Making Things Right with Totally Integrated Power (TIP)
Ralf Christian, CEO Low and Medium Voltage Making Things Right with Totally Integrated Power (TIP) siemens.com/hannovermesse Making Things Right with Totally Integrated Power (TIP) Trade LV 100 kw Industrial
Alternative data center power
Alternative data center power A quantitative TCO comparison of 400V AC and 600V AC power systems Abstract Power efficiency has become a critical focus for IT and facilities managers as they struggle to
(Examples of various colocation sites)
Overview The largest factor involved in maintaining business servers today are the fixed costs associated with data centers. The Colocation Environment is an outsourcing model whereby a colocation company
by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized! www.knuerr.
HIGH DENSITY COOLING SOLUTIONS by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized! optimiert! Setting benchmarks. Being the
David Skeans Universal Electric USA
Evolving Migration of Power Distribution From Under floor to Overhead David Skeans Universal Electric USA Introduction Hello, Good (state time of day), My Name is (state name) Having achieved the degrees
ABB PSPS Erich Steinmann; Generator control-2013
ABB PSPS Erich Steinmann; Generator control-2013 GENERATOR CONTROL THE MODULAR SOLUTION FOR GENERATORS To make sure that power is efficiently converted into electric energy, it is necessary to supervise
OASIS PRODUCT GUIDE. Data Centre Cooling INDIRECT EVAPORATIVE COOLER. Data Centres. Telecoms. EPX technology. Class leading performance
OASIS PRODUCT GUIDE Data Centres Telecoms EPX technology Class leading performance Fully configurable solutions INDIRECT EVAPORATIVE COOLER Data Centre Cooling 2 MUNTERS.COM/DATACENTRES Critical cooling
How To Design A Data Center
Approaches to Achieve Next-Generation Data Center Joe Li Business Head of Mission Critical Infrastructure Solutions What CIOs should know.. High way to Next-Generation Data Center Energy-Efficiency Scalability
Automation's Modular Containerized Datacenter Solutions
SAFE Automation's Modular Containerized Datacenter Solutions Automation's SAFE (Secure, Autonomous, Flexible, Efficient) Modular Containerized Datacenter offers a fast, flexible and efficient solution
P System Cubicles. Certified for more safety
P System Cubicles Prisma Plus LV Switchboards Certified for more safety Prisma Plus, an offer thought out for greater professionalism With the Prisma Plus P system, Schneider Electric proposes high-performance
The Intelligent AX1 Switchgear for Medium Voltage
The Intelligent AX1 Switchgear for Medium Voltage Leif Lundin, Manager of Research and Development, Division Medium Voltage and Compact Substations, ABB Distribution, Sweden Abstract The newly launched
Cisco Nexus 7000 Series Power Supply Modules
Cisco Nexus 7000 Series Power Supply Modules Product Overview The Cisco Nexus 7000 Series Power Supply Modules (Figures 1 and 2) deliver fault tolerance, high efficiency, load sharing, and hot-swappable
How to Maximize Data Center Efficiencies with Rack Level Power Distribution and Monitoring
How to Maximize Data Center Efficiencies with Rack Level Power Distribution and Monitoring Brian Rehnke e-pdu Business Development Manager November, 2011 The Problems Energy Usage in most data centers
How To Power A Bladecenter H Servers
Solutions Guide for IBM Data Center Architecture: IBM BladeCenter H Servers In today s high-demand enterprise environment, organizations need a reliable infrastructure to run compute-intensive applications
IBM Portable Modular Data Center Overview for Critical Facilities Round Table
Brian Canney Global Services Executive, IBM GTS Site and Facilities Services April 2011 IBM Portable Modular Data Center Overview for Critical Facilities Round Table 2009 IBM Corporation Key messages Containers
Power to the adaptable data center
Business Unit Manager, Data Center Solutions, Eaton s electrical group IT managers have more options than ever to tailor the power infrastructure to their unique data center and business requirements.
The Pros and Cons of Modular Systems
The Pros and Cons of Modular Systems Kevin Brown, Vice President Global Data Center Offer Schneider Electric Schneider Electric 1 Foundational BUSINESS OVERVIEW Rev 2 Desired characteristics of pre-fabricated
415V DISTRIBUTION FOR GREEN DATA CENTERS
White Paper: HMRP-WP001-A5 June 5, 2012 415V DISTRIBUTION FOR GREEN DATA CENTERS Prepared by: Anthony (Tony) Hoevenaars, P. Eng President and CEO Mirus International Inc. Copyright 2012 Mirus International
Easily connect your switchboards to facility management solutions
Easily connect your switchboards to facility management solutions Acti 9 communication system gives your customers complete control of their installations 100% exclusive to Schneider Electric Acti 9: The
Data Center Trend: Distributed Power in the White Space
Data Center Trend: Distributed Power in the White Space By Jason Anderson Product Line Manager Eaton Executive summary Cloud computing vendors and colocation data centers make every effort to maximize
Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application
Product overview brochure ABB Medium Voltage Products Our one-stop approach for every medium voltage application Overview ABB meets every need for reliable, safe and energy-efficient medium voltage switchgear,
Safety Relay Units. G9SR family. Diagnosis with LEDs Selectable operating modes and times Increased extension possibilities. industrial.omron.
Safety Relay Units G9SR family Diagnosis with LEDs Selectable operating modes and times Increased extension possibilities industrial.omron.eu/g9sr ... A complete standalone Safety Relay Unit family - G9SR
Emirates Aluminium starts up World s first fully integrated power distribution system from ABB
Reprint from Aluminium World 2009, Volume 2 Emirates Aluminium starts up World s first fully integrated power distribution system from ABB Emirates Aluminium (EMAL), a joint venture between Abu Dhabi s
Is an energy-wasting data center draining your bottom line?
Abstract Is an energy-wasting data center draining your bottom line? New technology options and power distribution strategies can dramatically reduce the cost and carbon footprint of your data center.
Power Solutions for Data Centers Metering and protection architecture guide
Power Solutions for Data Centers Metering and protection architecture guide The purpose of this guide is to provide technical guidelines to designers and field engineers who specify metering and protection
Data Center. www.datacenter.rdm.com
Cover photo 090.6323 www.datacenter.rdm.com Data Center Headquarters Reichle & De-Massari AG Binzstrasse 32 CHE-8620 Wetzikon/Switzerland Phone +41 (0)44 933 81 11 Fax +41 (0)44 930 49 41 www.rdm.com Your
Common mistakes in datacentre planning
Common mistakes in datacentre planning White Paper Last edited: March 2013 Document Control Document Information Title Author Common mistakes in datacentre planning Nick Ewing This document is based upon
High-density modular data center making cloud easier. Frank Zheng Huawei
High-density modular data center making cloud easier Frank Zheng Huawei 2012-10-10 Content 1 2 3 4 Cloud s impact to data center Concerns of DC construction 4S DC making cloud easier Success stories Cloud?
Greening The Data Center
Greening The Data Center A Five Step Method for CIO s and Data Center Managers Professionals who manage Data Centers know what is expected from them for performance and uptime. What many are only just
Increase the efficiency of power distribution in your high-density data center
Increase the efficiency of power distribution in your high-density data center Abstract As power density in modern data centers increases, more focus has been placed on improving efficiency in the power
Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC
TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while
Essential NCPI Management Requirements for Next Generation Data Centers
Essential NCPI Requirements for Next Generation Data Centers By Ted Ives White Paper #14 1 Executive Summary The management of physical infrastructure in data centers can no longer be considered independently
Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation
IOSR Journal of Engineering (IOSRJEN) ISSN (e): 2250-3021, ISSN (p): 2278-8719 Vol. 04, Issue 01 (January. 2014), V6 PP 01-12 www.iosrjen.org Paper on Basbar Trunking System for Electrical Supply to Industrial
SERVICE LEVEL AGREEMENT! CONFIRMATION
SERVICE LEVEL AGREEMENT CONFIRMATION BRINGING ENTERPRISE TO SMB RELIABILITY & LOWERING THE TCO What we built Qsan s unique character on, starts from the approach. We had a dream of bringing an enterprise
Il Progetto INTEGRIS. Risultati e nuove prospettive per lo sviluppo delle Smart Grid October 2nd 2013 Brescia
Il Progetto INTEGRIS. Risultati e nuove prospettive per lo sviluppo delle Smart Grid October 2nd 2013 Brescia From INTEGRIS a solution architecture for energy smart grids Jean Wild - Schneider Electric
Power protection for data centers
Power protection for data centers Power protection for data centers Data centers are major power users, with larger installations consuming tens of megawatts. As customers are often highly reliant on the
415V DISTRIBUTION FOR GREEN DATA CENTERS
White Paper: HMRP-WP001-A1 October 1, 2010 415V DISTRIBUTION FOR GREEN DATA CENTERS Prepared by: Anthony (Tony) Hoevenaars, P. Eng President and CEO Mirus International Inc. Copyright 2005 Mirus International
ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA
MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,
Energy Savings in the Data Center Starts with Power Monitoring
Energy Savings in the Data Center Starts with Power Monitoring As global competition intensifies, companies are increasingly turning to technology to help turn mountains of data into a competitive edge.
Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions
Data Centre Solutions... energy efficient by design APC by Schneider Electric Elite Data Centre Partner APC s leading Elite Data Centre Solutions Partner providing customers with expert advice, integration
Sovereign. The made to measure data centre
Sovereign D ATA C O N N E C T The made to measure data centre Prime Location Within touching distance of everything that s important. 2 Your Customer-Centric Data Centre For the vast majority of organisations
Increasing Data Center Efficiency by Using Improved High Density Power Distribution
Increasing Data Center Efficiency by Using Improved High Density Power Distribution By Neil Rasmussen White Paper #128 Executive Summary A new approach to power distribution for high density server installations
IFS ApplIcAtIonS For ElEctronIc components xxxxxxxxxxxxx
IFS Applications for ELECTRONIC COMPONENTS xxxxxxxxxxxxx OUR SOLUTION S DNA When we first set out to create IFS Applications over 25 years ago, our goal was to make the most usable business software on
SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions
SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS POWER DISTRIBUTION RACKS IN A MISSION CRITICAL SYSTEM MODULES IN A MISSION CRITICAL SYSTEM UPS Convertor Main Inverter Load Battery BPC UPS & BATTERY
Safeguard your critical IT assets in a highly secure, fully redundant, environmentally-conditioned and constantly monitored hosting space to receive
Co-Location Services Safeguard your critical IT assets in a highly secure, fully redundant, environmentally-conditioned and constantly monitored hosting space to receive optimum performance 24x7. SERVICE
Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime
Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime Containerized Infrastructure for Business-Critical Continuity Are you deploying a remote site faster than you can
Securing your electrical installations Prisma,
Securing your electrical installations Prisma, an optimised solution for type tested low voltage switchboards up to 3200 A Table of contents Developing installation safety 4 Prisma P * Electrical switchboards
Colt Colocation Services. 2010 Colt Technology Services Group Limited. All rights reserved.
Colt Colocation Services 2010 Colt Technology Services Group Limited. All rights reserved. Award winning Colt Data Centre Solutions 2012: Modular Data Centre Solution of the year winner at 5 th Datacentre
SMART SHELTER CONTAINER
Da ta Ce nt er Total Flexibility and Security in a Modular Data Center Advantages Environmentally Friendly Short Delivery Time Smart Shelter Container (SSC) solution provides a fully functional Data Center
Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria
Tier 3+ 1 Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria Abstract: Schoolcraft College is constructing a High Availability (HA) Data Center
Data Center Facility Basics
Data Center Facility Basics Ofer Lior, Spring 2015 Challenges in Modern Data Centers Management, Spring 2015 1 Information provided in these slides is for educational purposes only Challenges in Modern
QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA - 12859 North America Version 5 August 22, 2008 Page 1
Overview It's getting harder to manage a data center efficiently, with rising utility bills and ever-increasing demands due to processor power and server density increases. Growing user requests mean heavier
Extend the Life of Existing Switchgear
Extend the Life of Existing Switchgear January 2011/1910DB1002 by Hal Theobald, Product Manager Schneider Electric USA, Inc. Make the most of your energy SM Summary Introduction... p 3 Maintenance Requirements...
Improving Data Centers Energy Reliability & Efficiency. December 2015
Improving Data Centers Energy Reliability & Efficiency December 2015 Background The challenges Alternative solutions SATEC approach Advantages Cases Summary Data Centers Energy Challenges Worldwide Data
Cisco IT Data Center and Operations Control Center Tour
Cisco IT Data Center and Operations Control Center Tour Inside the Build Room Page 1 of 8 5. Inside the Build Room Introduction Figure 1. Inside the Build Room Ian: The purpose of the Build room is for
Electrical Network Management System
Electrical Network Management System Optimisation of the electrical network Measure to understand Understand to control Control to optimise Cost of power and fluids Power quality Power availability 2 Improvement
Opportunity of Energy Saving in electrical path is lesser as compared to other areas
Data Centre Power Map ` Energy Optimization Techniques Data Center Power Chain Venkat Rao B Country Manager Power Products Data Center Power Draws Cooling About 35 40 % Sources of Energy Waste Fans / Blowers
Top of Rack: An Analysis of a Cabling Architecture in the Data Center
SYSTIMAX Solutions Top of Rack: An Analysis of a Cabling Architecture in the Data Center White paper Matthew Baldassano, Data Center Business Unit CommScope, Inc, June 2010 www.commscope.com Contents I.
Mission Critical Data Center Systems
Mission Critical Systems Mission Critical/ Electrical Distribution Systems Data center electrical distribution designs are rapidly evolving, driven by needs such as increasing power densities, energy efficiency,
Comparative study for cables and busbars
Comparative study for cables and busbars Preliminary considerations To compare the prices of two categories of product as different as traditional cables and busbars, it is necessary to make some preliminary
Electricity, Gas and Water: The European Market Report 2014
Brochure More information from http://www.researchandmarkets.com/reports/2876228/ Electricity, Gas and Water: The European Market Report 2014 Description: The combined European annual demand for electricity,
SUPPLY, DEMAND, ENERGY AND LOCATION: THE FOUR PILLARS TO SUCCESS
SUPPLY, DEMAND, ENERGY AND LOCATION: THE FOUR PILLARS TO SUCCESS DC RADAR The second edition of the Arcadis European Data Centre Radar, produced in conjunction with ixconsulting, is based upon extensive
StruxureWare Power Monitoring Expert Data Center Edition. Power system intelligence and reliability for your entire infrastructure
StruxureWare Power Monitoring Expert Data Center Edition Power system intelligence and reliability for your entire infrastructure revolution A power system to meet your changing demands. 2 StruxureWare
Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server
Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server High availability for lower expertise
Tel.X Ni-Cd battery. The compact solution for stationary applications
Tel.X NiCd battery The compact solution for stationary applications Tel.X, delivering highenergy performance in a compact maintenancefree package Tel.X: guaranteed power continuity for remote or hard to
European Rack and Rack Options Market
Brochure More information from http://www.researchandmarkets.com/reports/2701935/ European Rack and Rack Options Market Description: The European rack and rack options market is growing with still high
PX100 MBP with Configurable Distribution
PX100 MBP with Configurable Distribution High-performance, right-sized, 3-phase power protection with industry-leading efficiency, availability, and performance for small and medium data centers July 2012
Panduit Infrastructure Management Software for Data Centers and Enterprises
Panduit Infrastructure Management Software for Data Centers and Enterprises SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers SmartZone Rack Energy Kits Features: Simple
APC 3Phase Power Distribution
APC 3Phase Power Distribution North American 3 Phase Business Development Team All content in this presentation is protected 2008 American Power Conversion Corporation Objectives Understand the entire
Data Center Integrated solutions
Data Center Integrated solutions PERFORMANCE AND RELIABILITY AT THE HEART OF DATA CENTERS The growing number of business and technical demands placed on data centers today are becoming increasingly critical:
Colocation Selection Guide. Workspace Technology Ltd
Colocation Selection Guide Workspace Technology Ltd Technology House 5 Emmanuel Court Reddicroft Sutton Coldfield West Midlands B72 1TJ Tel 0121 354 4894 Fax 0121 354 6447 www.workspace-technology.com
Data Sheet Fujitsu PRIMERGY CX1000 S1 with 38 cloud server nodes
Data Sheet Fujitsu PRIMERGY CX1000 S1 with 38 cloud server nodes The Cool-Central architecture for Scale-Out Cloud Data Centers: Scale Big- Spend Small PRIMERGY CX1000 is a new product category within
Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert
Data Center Consolidation Trends & Solutions Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert Agenda Traditional Data Centers Drivers of a Changing Environment Alternate
How To Build A Powerline Box Powerline Generator
Quick Reference Guide DYNAMIC Series Dynamic Series is a broad product family that provides connector solutions ranging from signal level circuitry through power circuit connectivity in a ruggedized, industrialized