1 Essential Power System Requirements for Next Generation Data Centers White Paper #4 Revision 4
2 Executive Summary Effective mission critical installations must address the known problems and challenges relating to current and past data center designs. This paper presents a categorized and prioritized collection of power system challenges and requirements as obtained through systematic user interviews. 2
3 Introduction Despite revolutionary changes in IT technology and products over the past decades, the design of power infrastructure for mission critical installations like data centers and network rooms has changed very little since Although IT equipment has always required electrical power, the way that IT systems are deployed today has created new power-related problems which were not foreseen when the powering principles for the modern data center were developed over 30 years ago 1. In this paper, a systematic approach of identifying and classifying user problems provides insight regarding the nature and characteristics of power systems in next generation mission critical installations. Survey A survey of management personnel relating to mission critical installations was conducted, interviewing corporate CIO s, Facility Managers, and IT Managers. Over 150 people were interviewed from over 90 different organizations including Fortune 1000 companies, Government and Education, and Service Providers. Approximately 50% of customers interviewed were from North America, 20% from Europe, and 30% from Japan, Pacific, Australia, and Asia (JPAA) region. The one year survey utilized Voice of the Customer techniques, which relies on data collection of verbal and/or written responses to open-ended questions. This provides extremely unstructured responses, with the advantage that the responses are not limited or constricted by preconceptions within the question. During the course of the survey, some of the questions were expanded and/or changed in order to clarify ambiguous responses. Results: Power System Challenges in Mission Critical Installations Survey responses were grouped according to common concepts, and for each group a solution requirement, corresponding to a challenge for mission critical installation design, was derived. This process identified 22 core challenges. These core challenges were then further grouped according to theme into the following 5 key theme areas: Lifecycle Costs Adaptability / Scalability Availability Manageability Maintenance / Serviceability 3
4 For each theme area, the challenges, underlying problems, and power system requirements are presented in tabular form. The highest priority problems are listed first under each theme. The priority was determined by combining number of mentions weighted by priority as expressed by the respondents. Lifecycle Cost Challenges Challenge Underlying problems Power System Requirements Optimize capital investment and available space Accelerate speed of deployment Lower the cost of service contracts Recover from false start or low ROI projects Bill users for power System requirements are difficult to predict and systems are frequently oversized. The planning and unique engineering involved takes 6-12 months, which is too long when compared with the planning horizon of the organization. Service contracts on unused or underutilized equipment is wasted. It is very difficult to downsize or move a project once it is underway, but changing business issues frequently require such changes. It is desirable but currently impractical to charge users based on their actual power consumption. Modular systems that grow with the requirement. Pre-engineered solutions that eliminate and/or simplify most planning and engineering. Right sized systems that can be scaled rapidly with changing requirements would reduce oversizing and the wasted service contracts associated with underutilized equipment. Modular and portable power infrastructure that can be moved to other facilities when required. Power metering The survey found the lifecycle cost challenges were the most important requirement, particularly for respondents from top level management in their organizations. The survey revealed a pattern of oversizing and underutilization of data centers and network rooms in all types of businesses. This key issue is further studied in APC White Paper #37: Avoiding Costs From Oversizing Data Center and Network Room Infrastructure 4
5 Adaptability / Scalability Challenges Challenge Underlying problems Power System Requirements Reduce the extensive engineering required for custom installations Plan for a power density that is increasing and unpredictable Adapt to ever-changing requirements Manage the proliferation of branch circuits Cope with the increasing number and poor quality of circuit breakers This engineering is time consuming, expensive, a key source of downstream quality problems, and it makes it very difficult to expand or modify the installation later. Industry projections of power density requirements show great uncertainty but new data centers must meet requirements for 10 years. Different power requirements, voltage requirements, outlet requirements, even the need for DC may occur at any time in any rack. In a dual path system there may be 6 or more branch circuits per rack, and these circuits are constantly being rewired. It is very difficult to keep track of this high quantity of changing branch circuits and particularly to determine if they are overloaded. Data centers and network rooms use the same types of breakers for branch circuits that are used for residential/light industrial applications. These breakers are not of high quality, frequently do not meet their specifications, and are used in such a high quantity that their shortcomings become a statistically significant part of data center down-time. Pre-engineered solutions that eliminate and/or simplify most planning and engineering. System design that can be easily adapted, even retrofit, to power high density racks which might be isolated cases or widespread in the future A rack power infrastructure that allows quick and tool-less changeover for different voltages, power capacities, outlets, and DC. Higher power distribution to the rack, eliminate re-wiring, and provide local and remote metering. Better quality breakers, pre-installed and tested. The solution requirements to meet the Adaptability Challenges share many features in common with the solution requirements for life cycle costs. In particular, pre-engineered, standardized, and modular solutions are needed. Many issues related to adaptability relate to the architecture of the power distribution system to the rack. This subject is discussed in detail in APC White Paper #29: Rack Powering Options for Data Centers and Network Rooms. 5
6 Availability Challenges Challenge Underlying problems Power System Requirements Minimize human error Minimize points of failure between UPS and critical load Reduce failure points that drop customers simultaneously Eliminate harmonics Learn from past problems and share learning across systems Uniquely engineered, poorly documented systems. Changing requirements require rewiring of live systems. Large centralized systems remotely located from the load with complex output power distribution systems, creating the need for additional redundancy features in the distribution system such as static transfer switches. Large centralized systems with complex coordination among circuit breakers create a condition where faults can unexpectedly propagate across systems. Large centralized UPS system that present a large harmonic load to the utility, switchgear, and backup generators; creating unexpected interactions and requiring oversizing. Uncertainty regarding the magnitude and effects of harmonics in the IT loads. Uniquely engineered systems where learning on one system cannot be transferred to another. No clear way that solutions for one customer s problem are communicated to other similar customers. Pre-engineered solutions that have comprehensive documentation and mistake-proofing features. Systems that minimize the number of breakers and amount of wiring between the UPS and the loads. Systems that minimize the number of breakers and amount of wiring between the UPS and the loads, and that are preengineered and tested for breaker coordination. UPS systems with input power factor correction. Loads that have input power factor correction. Distribution equipment that is preengineered to handle harmonics and is protected against harmonic overload problems. Pre-engineered standardized systems where learning is shared through manufacturer notifications and automatic upgrade procedures. Survey respondents universally identified human error as the dominant problem relating to availability. The Uptime Institute has reported that over 50% of all load drop events in data centers are caused by human error. Respondents expressed frustration at the wide variety of the types of human errors, and the number of unique types of human errors, which appeared almost impossible to anticipate. Nevertheless, a common denominator identified was the fact that humans take actions based on their own mental model of how the system behaves, and very often their understanding of the system is wrong. These human errors occur during operation of the system, but they also occur during design and installation. Standardization, automation, and simplification are required to overcome these problems. 6
7 Survey respondents showed a lack of awareness regarding the dramatic reductions in harmonics created by recent generations of IT equipment. This subject is discussed in more detail in APC White Paper #26: Hazards of Harmonics and Neutral Overloads. Manageability Challenges Challenge Underlying problems Power System Requirements Management of power at the outlet level Monitor power attributes at the rack level Provide predictive failure analysis Unauthorized use of unused outlet receptacles creates unexpected overload conditions. Some IT equipment requires power-cycling to maximize performance or to reset from hungup conditions. Powering down certain loads according to a schedule for security or energy conservation is a manual and tedious process. Difficulty in determining racks that have high thermal loads, and racks that are near overload. Difficulty in associating branch circuit loads with racks due to constant reconfiguration. For dual path systems, difficulty in determining whether remaining circuits will overload when one path goes down. Most power components fail or trip unexpectedly. No advance warning is provided that could allow corrective actions that might prevent load loss. Ability to control power at the outlet level, along with pre-engineered and easy to use tools to monitor and control large numbers of outlets. Graphical user interfaces and automatic notification which report, manage, and notify based on parameters at the rack level. Instrument the power system in a way that provides advance warning of component failures. In the case of consumable or finite-life items, automatically notify regarding remaining expected life and replacement intervals. The manageability solution requirements are extremely expensive to design, install, and test in uniquely engineered systems. These challenges clearly suggest the need for pre-engineered, pre-tested, and standardized management tools. Survey respondents showed a lack of awareness regarding the time-varying power consumption of the newest generation of IT equipment. Therefore managing this issue did not emerge as a challenge. Nevertheless, this issue is expected to emerge as a key manageability challenge in the near future and is discussed in detail in APC White Paper #43: Dynamic Power Variations in Data Centers and Network Rooms. 7
8 Serviceability Challenges Challenge Underlying problems Power System Requirements Decrease Mean-Time-To- Recover (includes repair time plus technician arrival, diagnosis, and parts arrival times) Simplify the complexity of the system Eliminate hot work Minimize vendor interfaces Learn from past problems and share learning across systems Spare parts are not readily available. Large systems that require complex disassembly process to diagnose and to repair. Systems are so complex that service technicians and in-house maintenance staff make errors and drop loads when operating and maintaining the system. Status of the system cannot be easily determined or communicated during a crisis. Third party control systems are complex and unique and are never thoroughly tested, resulting in unexpected behavior during fault conditions The need to frequently change branch circuits, combined with the need to keep loads running 7x24, creates the need to re-wire circuits on live panel boards. This creates the opportunity for many types of human-error failures, and a serious health hazard. Power systems often involve 10 or more vendors and it becomes difficult for inhouse and even vendor personnel to determine which vendor is responsible for a problem, leading to the wasting of time and money. Uniquely engineered systems where learning on one system cannot be transferred to another. No clear way that solutions for one customer s problem are communicated to other similar customers Modular systems using standardized spare parts that are inventoried on-site or locally. Simple repair procedures that do not require complex disassembly. Standardized systems with standardized switchgear and standardized nomenclature. Pre-engineered and pre-tested control systems that don t take a lot of time to set up. System should adapt to changing voltage, power, and outlet requirements without the need for re-wiring on live panel boards. Pre-integrated and pre-manufactured systems where it is clear who is responsible for a problem. Pre-engineered standardized systems where learning is shared through manufacturer notifications and automatic upgrade procedures The last challenge involving learning from past problems, was expressed by some respondents as an availability issue, and by others as a service issue. Therefore it appears in both tables. 8
9 Power Systems for Mission Critical Installations To satisfy the mission critical installation powering challenges identified in this survey, there are a number of changes required from current design practice. Many of these changes will require changes in the technology and design of power equipment, and how it is specified. Integration of the components of the power subsystem must move away from the current practice of unique system designs, and toward preengineered and even pre-manufactured solutions. Such solutions would ideally be modular and standardized, expandable at will, and would ship complete but in parts that would rapidly plug together on site. Standardization will facilitate the learning process. By spreading the cost of developing high performance management systems across large numbers of standardized installations, advanced power management would be affordable to all customers. Conclusions A systematic analysis of customer problems relating to data center and network room power systems provides a clear statement of direction for next generation mission critical installations. The most pressing problems that are not solved by current design practices and equipment have the common theme of the inability of the data center to adapt to change. Mission critical installation power systems must be more adaptable to changing requirements, in order to improve both availability and cost effectiveness. In many industries, a maturity level is reached where new advances in reliability, cycle time, and cost require standardization, pre-engineering, and modularization. Designers of mission critical installations, designers of the power equipment used in them, and owners should consider whether this point has been reached. The results of the survey in this paper suggest the need for a new generation of adaptable power systems for mission critical installations. References 1) FIPS PUB 94 Guideline for Computer Power for ADP Installations ; National Technical Information Service 9
Essential Cooling System Requirements for Next Generation Data Centers
Essential Cooling System Requirements for Next Generation Data Centers White Paper #5 Revision 3 Executive Summary Effective mission critical installations must address the known problems and challenges
Power Distribution Considerations for Data Center Racks
Power Distribution Considerations for Data Center Racks Power Distribution Considerations for Data Center Racks Table of Contents 3 Overview 4 At what voltage do you run all the IT equipment? 4 What electrical
Essential NCPI Management Requirements for Next Generation Data Centers
Essential NCPI Requirements for Next Generation Data Centers By Ted Ives White Paper #14 1 Executive Summary The management of physical infrastructure in data centers can no longer be considered independently
Dynamic Power Variations in Data Centers and Network Rooms
Dynamic Power Variations in Data Centers and Network Rooms By Jim Spitaels White Paper #43 Revision 2 Executive Summary The power requirement required by data centers and network rooms varies on a minute
Avoiding Costs from Oversizing Data Center and Network Room Infrastructure
Avoiding Costs from Oversizing Data Center and Network Room Infrastructure White Paper 37 Revision 6 by Neil Rasmussen > Executive summary The physical and power infrastructure of data centers and network
Overload Protection in a Dual-Corded Data Center Environment
Overload Protection in a Dual-Corded Data Center Environment White Paper 206 Revision 0 by Neil Rasmussen Executive summary In a dual-corded environment, the loss of power on one path will cause the load
Avoiding Costs from Oversizing Data Center and Network Room Infrastructure
Avoiding Costs from Oversizing Data Center and Network Room Infrastructure White Paper 37 Revision 7 by Neil Rasmussen > Executive summary The physical infrastructure of data centers and network rooms
Data center solutions Medium & large enterprise, multi-tenant and hyperscale. Energize your data center, maximize the value of your investment
Data center solutions Medium & large enterprise, multi-tenant and hyperscale Energize your data center, maximize the value of your investment We serve the needs of data centers of all sizes, around the
Physical Infrastructure Management Solutions
Physical Infrastructure Management Solutions Physical Infrastructure Challenges Require Innovative Solutions The Need for In-Depth Network Intelligence. With increased acceptance of virtualization, cloud
Dynamic Power Variations in Data Centers and Network Rooms
Dynamic Power Variations in Data Centers and Network Rooms White Paper 43 Revision 3 by James Spitaels > Executive summary The power requirement required by data centers and network rooms varies on a minute
Power and Cooling Capacity Management for Data Centers
Power and Cooling Capacity for Data Centers By Neil Rasmussen White Paper #150 Executive Summary High density IT equipment stresses the power density capability of modern data centers. Installation and
Increasing Data Center Efficiency by Using Improved High Density Power Distribution
Increasing Data Center Efficiency by Using Improved High Density Power Distribution By Neil Rasmussen White Paper #128 Executive Summary A new approach to power distribution for high density server installations
Efficiency and Other Benefits of 208 Volt Over 120 Volt Input for IT Equipment
Efficiency and Other Benefits of 208 Volt Over 120 Volt Input for IT Equipment By Neil Rasmussen White Paper #27 Revision 2 Executive Summary Decisions made regarding the distribution of 208V or 120V power
Considerations for a Highly Available Intelligent Rack Power Distribution Unit. A White Paper on Availability
Considerations for a Highly Available Intelligent Rack Power Distribution Unit A White Paper on Availability Introduction Data centers are currently undergoing a period of great change. Data center managers
PREMIER SERVICES MAXIMIZE PERFORMANCE AND REDUCE RISK
MAXIMIZE PERFORMANCE AND REDUCE RISK 1 BROCHURE COMPLEXITIES IN MISSION CRITICAL SYSTEMS CONTINUE TO INCREASE Mission critical communications systems have become increasingly complex as more features and
High-Efficiency AC Power Distribution for Data Centers
High-Efficiency AC Power Distribution for Data Centers White Paper 128 Revision 2 by Neil Rasmussen > Executive summary The use of 240 volt power distribution for data centers saves floor space, simplifies
A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture
A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture By Neil Rasmussen White Paper #129 Executive Summary Significant improvements in efficiency, power density, power monitoring,
How To Get A Great Service From Swersey Electric
Schneider Electric Datacenter Operation Services This comprehensive set of services for your datacenter infrastructure provides a customized solution. We help you maximize your investment to keep your
HP Systems Insight Manager
HP Systems Insight Manager Unified Platform Management HP Systems Insight Manager software provides a simple, secure, unified platform to manage server and storage environments. It enables [CustomerName]
PX100 MBP with Configurable Distribution
PX100 MBP with Configurable Distribution High-performance, right-sized, 3-phase power protection with industry-leading efficiency, availability, and performance for small and medium data centers July 2012
A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture
A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture White Paper 129 Revision 1 by Neil Rasmussen > Executive summary Significant improvements in efficiency, power density,
Power to the adaptable data center
Business Unit Manager, Data Center Solutions, Eaton s electrical group IT managers have more options than ever to tailor the power infrastructure to their unique data center and business requirements.
Implementing Energy Efficient Data Centers
Implementing Energy Efficient Data Centers By Neil Rasmussen White Paper #114 Executive Summary Electricity usage costs have become an increasing fraction of the total cost of ownership (TCO) for data
Wireless Networks and Power Quality
Will installing wireless networking change my back-up power requirements? What data do I need to know in order to determine my wireless network back-up power requirements? What other issues should I consider
415V DISTRIBUTION FOR GREEN DATA CENTERS
White Paper: HMRP-WP001-A5 June 5, 2012 415V DISTRIBUTION FOR GREEN DATA CENTERS Prepared by: Anthony (Tony) Hoevenaars, P. Eng President and CEO Mirus International Inc. Copyright 2012 Mirus International
Creating Order from Chaos in Data Centers and Server Rooms
Creating from in Data Centers and Server Rooms By Dennis Bouley White Paper #119 Executive Summary Data center professionals can rid themselves of messy racks, sub-standard under floor air distribution,
Power and Cooling for Ultra-High Density Racks and Blade Servers
Power and Cooling for Ultra-High Density Racks and Blade Servers White Paper #46 Introduction The Problem Average rack in a typical data center is under 2 kw Dense deployment of blade servers (10-20 kw
Power protection for data centers
Power protection for data centers Power protection for data centers Data centers are major power users, with larger installations consuming tens of megawatts. As customers are often highly reliant on the
Smart Data Center Solutions
Smart Data Center Solutions New Data Center Challenges Require New Solutions Data Center Architecture. Inside and Out. Data centers are mission-critical facilities. A silo-based approach to designing,
shopinkelowna.com/mr--electric---home- Electrician-West-Kelowna/648681.htm
shopinkelowna.com/mr--electric---home- Electrician-West-Kelowna/.htm Website Visibility: by Search Engine % Keyword Rankings: Summary Search engine Keywords Moved Up/Down - - Keyword Rankings Keyword Affordable
415V DISTRIBUTION FOR GREEN DATA CENTERS
White Paper: HMRP-WP001-A1 October 1, 2010 415V DISTRIBUTION FOR GREEN DATA CENTERS Prepared by: Anthony (Tony) Hoevenaars, P. Eng President and CEO Mirus International Inc. Copyright 2005 Mirus International
Power. When and where you need it.
Power Base Power. When and where you need it. Power Base is the only modular electrical system that delivers seamless plug-and-play power from the closet to the desktop. It s also the only system backed
Fundamentals of Power
Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At
Standardization and modularity as the foundation of data center UPS infrastructure
ABB White Paper Standardization and modularity as the foundation of data center UPS infrastructure - ABB Power Protection Product Group Doc name: Advantages of modular and standardized UPS Date: 19.11.2013
Measuring Energy Efficiency in a Data Center
The goals of the greening of the Data Center are to minimize energy consumption and reduce the emission of green house gases (carbon footprint) while maximizing IT performance. Energy efficiency metrics
Application Briefs: Remote Office Environment
Overview Remote offices are a definite sign of growth, but it can constitute an immense challenge from an IT infrastructure standpoint. Remote offices may include a wide variety of wiring closets and small
Energy Management Solutions
Energy Management Solutions Introducing the world s most innovative intelligent Power Distribution Units (ipdus) designed to simplify rack energy and environmental management of your data center. Enlogic
M-series FOUNDATION Fieldbus I/O
April 2013 Page 1 M-series FOUNDATION Fieldbus I/O Use DeltaV state-of-the-art FOUNDATION Fieldbus redundant I/O for your process control system Increases input/output Takes advantage of all smart device
The Pros and Cons of Modular Systems
The Pros and Cons of Modular Systems Kevin Brown, Vice President Global Data Center Offer Schneider Electric Schneider Electric 1 Foundational BUSINESS OVERVIEW Rev 2 Desired characteristics of pre-fabricated
EAGLE Power over Ethernet Products for IP Powering Applications. Flexibility, Simplicity and Value LAN POWER SYSTEMS. Trend Datacom USA, Inc.
EAGLE Power over Ethernet Products for IP Powering Applications Flexibility, Simplicity and Value LAN POWER SYSTEMS Trend Datacom USA, Inc. Presentation Agenda IEEE802.3af PoE Technology Definitions and
Management Strategy for Network Critical Physical Infrastructure
Management Strategy for Network Critical Physical Infrastructure White Paper #100 Executive Summary When choosing a management solution for the physical infrastructure of IT networks, management of individual
Power Distribution Systems for the Dell PowerEdge M1000e Modular Server Enclosure - Selection and Installation
One Dell Way Round Rock, Texas 78682 www.dell.com Dell Enterprise White Paper Power Distribution Systems for the Dell PowerEdge M1000e Modular Server Enclosure - Selection and Installation January, 2008
Data Center Trend: Distributed Power in the White Space
Data Center Trend: Distributed Power in the White Space By Jason Anderson Product Line Manager Eaton Executive summary Cloud computing vendors and colocation data centers make every effort to maximize
Revitalising your Data Centre by Injecting Cloud Computing Attributes. Ricardo Lamas, Cloud Computing Consulting Architect IBM Australia
Revitalising your Data Centre by Injecting Attributes Ricardo Lamas, Consulting Architect IBM Australia Today s datacenters face enormous challenges: I need to consolidate to reduce sprawl and OPEX. I
Availability and Disaster Recovery: Basic Principles
Availability and Disaster Recovery: Basic Principles by Chuck Petch, WVS Senior Technical Writer At first glance availability and recovery may seem like opposites. Availability involves designing computer
COBRA Power over Ethernet Products for IP Surveillance Applications LAN POWER SYSTEMS. Trend Datacom USA, Inc.
COBRA Power over Ethernet Products for IP Surveillance Applications LAN POWER SYSTEMS Trend Datacom USA, Inc. Presentation Agenda IEEE802.3af PoE Technology Definitions and Implementations IP Surveillance
The Advantages of Row and Rack- Oriented Cooling Architectures for Data Centers
The Advantages of Row and Rack- Oriented Cooling Architectures for Data Centers By Kevin Dunlap Neil Rasmussen White Paper #130 Executive Summary Room cooling is an ineffective approach for next-generation
Data Center Solutions
Data Center Solutions New Data Center Challenges Require New Solutions Data Center Architecture. Inside and Out. Data centers are mission-critical facilities. A silo-based approach to designing, deploying
ABB PSPS Erich Steinmann; Generator control-2013
ABB PSPS Erich Steinmann; Generator control-2013 GENERATOR CONTROL THE MODULAR SOLUTION FOR GENERATORS To make sure that power is efficiently converted into electric energy, it is necessary to supervise
CUSTOMER EXPERIENCE CENTER
v CUSTOMER EXPERIENCE CENTER ABOUT THE CUSTOMER EXPERIENCE CENTER MAKE YOUR DATA CENTER AS DYNAMIC AS YOUR BUSINESS Emerson Network Power continuously strives to provide the best solutions by working collaboratively
Types of Electrical Meters in Data Centers
Types of Electrical Meters in Data Centers White Paper 172 Revision 1 by David Kidd and Wendy Torell > Executive summary There are several different types of meters that can be designed into a data center,
STORAGE CENTER. The Industry s Only SAN with Automated Tiered Storage STORAGE CENTER
STORAGE CENTER DATASHEET STORAGE CENTER Go Beyond the Boundaries of Traditional Storage Systems Today s storage vendors promise to reduce the amount of time and money companies spend on storage but instead
Who do the biggest names in servers, search, healthcare, cloud & financial services trust to provide power management solutions?
Who do the biggest names in servers, search, healthcare, cloud & financial services trust to provide power management solutions? The first team in power management ......... The world s best cabinet power
Engineering innovation
Eaton's Electrical Engineering Services & Systems Solutions Focus Seamless Solutions for Reliable, Efficient and Safe Power Systems Engineering innovation Progressive solutions for today s power systems
Increasing Data Center Resilience While Lowering PUE
Increasing Data Center Resilience While Lowering PUE Nandini Mouli, Ph.D. President/Founder esai LLC [email protected] www.esai.technology Introduction esai LLC esai LLC: Is a Disadvantaged woman-owned
Opportunity of Energy Saving in electrical path is lesser as compared to other areas
Data Centre Power Map ` Energy Optimization Techniques Data Center Power Chain Venkat Rao B Country Manager Power Products Data Center Power Draws Cooling About 35 40 % Sources of Energy Waste Fans / Blowers
Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions
Data Centre Solutions... energy efficient by design APC by Schneider Electric Elite Data Centre Partner APC s leading Elite Data Centre Solutions Partner providing customers with expert advice, integration
How SafePlug Smart Receptacles Can Save Money in Commercial Buildings
How SafePlug Smart Receptacles Can Save Money in Commercial Buildings by Steve Montgomery, P.E. 2D2C, Inc. SafePlug smart receptacle system add the ability to accurately identify exactly what appliance
Maintenance Service 1.1 ANNUAL PREVENTIVE MAINTENANCE 1.2 ON-SITE REMEDIAL SERVICES
Maintenance Service Statement of Work 1.0 Executive Summary - 1 - UPS/PDU Advantage Ultra UPS/PDU Advantage Ultra Service Service Table of Contents 1.0 Executive Summary 2.0 Features & Benefits 3.0 Details
SECURITY SOLUTIONS BANKING AND FINANCE
SECURITY SOLUTIONS BANKING AND FINANCE Pacom has developed a distinguished reputation as a global leader in the field of remote security management for the banking and financial market. Over 25 years of
Reducing Data Center Energy Consumption
Reducing Data Center Energy Consumption By John Judge, Member ASHRAE; Jack Pouchet, Anand Ekbote, and Sachin Dixit Rising data center energy consumption and increasing energy costs have combined to elevate
A Comparison of AC and DC Power Distribution in the Data Center Transcript
A Comparison of AC and DC Power Distribution in the Data Center Transcript Slide 1 Welcome to the Data Center University course on the A Comparison of AC and DC Power Distribution in the Data Center. Slide
Distributing Power to Blade Servers
Distributing Power to Blade Servers Ten steps to selecting the optimal power distribution design With the growth in blade servers with dual or triple power supplies, a single rack of equipment can easily
Guidelines for Specification of Data Center Power Density
Guidelines for Specification of Data Center Power Density By Neil Rasmussen White Paper #120 Executive Summary Conventional methods for specifying data center density are ambiguous and misleading. Describing
Applying Data Center Infrastructure Management in Collocation Data Centers
Applying Data Center Infrastructure Management in Collocation Data Centers Infrastructure Management & Monitoring for Business-Critical Continuity TM Applying Data Center Infrastructure Management (DCIM)
Electrical Efficiency Modeling for Data Centers
Electrical Efficiency Modeling for Data Centers By Neil Rasmussen White Paper #113 Revision 1 Executive Summary Conventional models for estimating electrical efficiency of data centers are grossly inaccurate
Application Note: Monitoring Branch Circuit Loads in Critical Facilities
Application Note: Monitoring Branch Circuit Loads in Critical Facilities Description of application: The AcquiSuite data acquisition server (DAS) from Obvius is used to monitor the electrical loads and
Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime
Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime Containerized Infrastructure for Business-Critical Continuity Are you deploying a remote site faster than you can
WHITE PAPER. Five Steps to Better Application Monitoring and Troubleshooting
WHITE PAPER Five Steps to Better Application Monitoring and Troubleshooting There is no doubt that application monitoring and troubleshooting will evolve with the shift to modern applications. The only
Power Distribution in Data Centers: STARLINE Track Busway, PX ipdus and Power IQ
Power Distribution in Data Centers: STARLINE Track Busway, PX ipdus and Power IQ 2011 Raritan Inc. Overview Data center managers are faced with increasingly challenging demands: supplying additional computing
Health Care Solutions
Health Care Solutions Increase Service Levels, Meet Expectations A Unified Approach to Health Care Automation Processes Hospitals, clinics, extended care facilities, and physician s offices are facing
Huawei Managed Services Unified Platform (MS UP) v1.0
Huawei Managed Services Unified Platform (MS UP) v1.0 Representation of Solution Functionality/Capability Utilizing etom, ITIL and TL 9000, Huawei Managed Services has integrated these three global standards
32VFD Variable Frequency Drives for Centrifugal Chillers
32VFD 32VFD Variable Frequency Drives for Centrifugal Chillers ENERGY-SAVING CONTROL FOR CENTRIFUGAL CHILLERS Reduce energy consumption in your existing centrifugal chiller Your chiller was specified to
Qualitative Analysis of Power Distribution Configurations for Data Centers
Qualitative Analysis of Power Distribution Configurations for Data Centers White Paper #4 2007 The Green Grid. All rights reserved. No part of this publication may be used, reproduced, photocopied, transmitted,
PRODUCT INFORMATION. SICK LifeTime Services. LifeTime Services for Machines and Systems
PRODUCT INFORMATION SICK LifeTime Services LifeTime Services for Machines and Systems Ordering Information Place your trust in us... SICK LifeTime Services Place your trust in us... SICK LifeTime Services
Calculating Total Power Requirements for Data Centers
Calculating Total Power Requirements for Data Centers By Richard Sawyer White Paper #3 Executive Summary Part of data center planning and design is to align the power and cooling requirements of the IT
Power distribution in data centres
Power distribution in data centres by Manuel Lotz / Matthias Ribbe White Paper 09 Copyright 2008 All rights reserved. Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Phone +49 (0)2772 505-0 Fax
CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers
CEMEP UPS The high environmental performance solution for power supply to high-availability data centers Exchanges of information and communication needs are growing at an exponential rate. That growth
Best Methods for Safe Hipot Testing
Best Methods for Safe Hipot Testing When working with electrical safety test equipment, instruments that output potentially dangerous voltages and currents, it is always important to regular review and
Electrical Efficiency Modeling of Data Centers
Electrical Efficiency Modeling of Data Centers By Neil Rasmussen White Paper 113 Executive Summary The conventional models used to estimate electrical efficiency of data centers are grossly inaccurate
> Executive summary. The Role of Isolation Transformers in Data Center UPS Systems. White Paper 98 Revision 0. Contents.
The Role of Isolation Transformers in Data Center UPS Systems White Paper 98 Revision 0 by Neil Rasmussen > Executive summary Most modern UPS systems do not include the internal s that were present in
Power & Environmental Monitoring
Data Centre Monitoring Made Easy Power & Environmental Monitoring Features & Benefits Packet Power provides the easiest, most cost effective way to capture detailed power and temperature information for
Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity
Proper Application of 415V Systems in North American Data Centers A White Paper from the Experts in Business-Critical Continuity Introduction Increasing pressure to reduce operating expenses and be more
NO-BREAK KS 7e. Concentrated Energy. 2750 kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM
NO-BREAK KS 7e Concentrated Energy e 2750 kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM Data Centre owners, operators and designers are required to meet ever increasing and
Data Center & IT Infrastructure Optimization. Trends & Best Practices. Mickey Iqbal - IBM Distinguished Engineer. IBM Global Technology Services
Data Center & IT Infrastructure Optimization Trends & Best Practices Mickey Iqbal - IBM Distinguished Engineer IBM Global Technology Services IT Organizations are Challenged by a Set of Operational Issues
How To Power A Bladecenter H Servers
Solutions Guide for IBM Data Center Architecture: IBM BladeCenter H Servers In today s high-demand enterprise environment, organizations need a reliable infrastructure to run compute-intensive applications