1-Port DS3 IMA Module Description and Technical Specifications. The 1-Port DS3 IMA module is illustrated in Figure 1. FAIL ACTIVE DS3 IMA L0S



Similar documents
8-Port E3/DS3 ATM Line Card Overview

Perle Protocol Transparent Media Converter Modules

24-Port Channelized E1/T1 Line Card Overview

CM400 High Speed Cable Modem User Manual

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

CM500 High Speed Cable Modem User Manual

HP UPS R1500 Generation 3

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

About the BitStorm 6051 POTS Splitter

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Full_IG.book Page 1 Monday, January 9, :11 PM. ProSafe 24 Port Gigabit Switch Installation Guide

Dial Backup Module (DBM) Two standoff posts, four washers, and four Phillips-head screws 14 RJ49C ISDN-U cable Warranty card

This is a product of VCCI Class B Compliance

MCR1900 Media Converter 19-Slot Chassis

Kvaser Mini PCI Express User s Guide

BroadBand PowerShield. User Manual

DGE-528T Gigabit Ethernet PCI Adapter User Manual

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

AXIS 291 1U Video Server Rack Installation Guide

Memory Modules User Guide

Perle 10/100/1000 Ethernet Media Converter Module

Rack Installation Instructions

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

Installation Guide. Wyse Z Class 2 and 4-GB RAM Upgrade Option Kit. Products: Z90DW, Z90SW, Z90D7, Z90S7. Issue: PN: L Rev.

Alcatel-Lucent 7705 SERVICE AGGREGATION ROUTER RELEASE PORT T1/E1 ASAP ADAPTER CARD INSTALLATION GUIDE

32-bit PCI 10/100/1000Mbps Gigabit Ethernet Card. User s Guide. FCC Warning. CE Mark Warning. VCCI Warning

Installing Cisco TelePresence MX200 G2 - Wheel Base

HP Personal Media Drive User s Guide

Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: PN: L Rev. A

PCI/PXI ETHERNET ADAPTERS

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

Cisco Channelized T1/E1 and ISDN PRI Modules

UPGRADING AND SERVICING GUIDE

L5354 ControlNet Communications Interface

USB 3.0 PCI Express. 2-Ports Host Controller Card. User Manual. HUSB302PCX

HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions

HP ProCurve High-Speed Transceivers Installation Guide

USB 2.0 Peripheral Switch USER MANUAL US221A / US421A

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card for Cisco 2821, 2851, and 3800 Series Integrated Services Routers

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

Refer installation of power supplies to qualified service personnel.

UIM-2T1 T1 Loop Bonding Uplink Interface Module

UniStream CPU-for-Panel

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

Upgrading and Servicing Guide

HP LaserJet 4050 and 4050 N Printers Getting Started Guide. English

Power Supply Guide Version 1.0 for D-Show

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

USB-to-Serial RS-232 Hub USB-to-Serial RS-422/485 Hub USER MANUAL UC2322 / UC2324 / UC4852 / UC4854

Cisco CWDM GBIC and CWDM SFP Installation Note

Triple Expansion Chassis

Tablet Management Rack 16

HP 16/18-Port Cable Management Kit Installation Guide

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

Cisco TelePresence VCR MSE 8220

StorTrends 3400 Hardware Guide for Onsite Support

AXIS 241Q/S Blade - Rack Solution Installation Guide

Compaq Presario Desktop Products. Upgrading and Servicing Guide

HP SATA/SAS hard drive and Solid State Drive installation

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Universal Quick Install Guide Quantum and Triton Boards

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

Cisco Communication Media Module

Cisco Unified IP Conference Phone 8831 Installation

Intel RAID Controller Troubleshooting Guide

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

Wireless Router Setup Manual

Set Up Your MXI -Express x4 System

Cisco ubr7200-npe-g2 Network Processing Engine

Installation Guide. N5101A Baseband Studio PCI Card. Overview

How To Install A Power Supply (Uplast) With A Battery Pack

ADSL Modem Installation Guide. Model # 36R515 Part # Rev. D Revision Date 12/2000. ADSL Modem Installation Guide

PS6500 Storage Arrays Rack Mount Instructions

How To Set Up An Andsl Modem Router For Internet Access

Emulex 8Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter IBM BladeCenter at-a-glance guide

Connecting Cisco Fast Ethernet ISDN PRI Network Modules to the Network

VS-0202 VS User Manual

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

iosafe Solo External Hard Drive

HP 22-in-1 Media Card Reader

HP PDU Management Module Overview

3-Port FireWire 800/400 PCI Host Card

USER MANUAL VS92A / VS94A / VS98A

Enhanced Performance, Versatility, High Availability, and Reliability at the Provider Edge

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

Installation Instructions. Wireless Adapter/Repeater. Introduction Rev C

T3 Mux M13 Multiplexer

Moxa EtherDevice Switch

Enterprise Management Engine Quick Start Guide

Data Sheet FUJITSU Storage ETERNUS LT260 Tape System

Changing the SIM in a BANDIT Product s GSM Card

USER MANUAL V5.0 ST100

PA500II Enterprise Mobile Computer

Communication Unit 560CMU05 Data sheet

Installation Guide for. 10/100 to Triple-speed Port Aggregator. Model TPA-CU Doc. PUBTPACUU Rev. 1, 12/08. In-Line

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

Transcription:

1-Port DS3 IMA Module Description and Technical Specifications Purpose of This Document This document identifies and describes the 1-Port DS3 IMA module and related safety information. It also includes procedures for installation and removal of the module from the PSAX chassis and verification of the initial module startup, as well as references to configuration documentation and troubleshooting assistance. Regulatory standards compliance is also described for the module. Identifying the Module The 1-Port DS3 IMA module is illustrated in Figure 1. FAIL ACTIVE DS3 IMA TX L0S RX Figure 1. 1-Port DS3 IMA Module The 1-Port DS3 IMA module has been tested and verified by Lucent Technologies to operate with the following PSAX software releases. COMCODE Software Release Model Faceplate Label 300266004 6.2.0 and higher 23N68 DS3 IMA 1-Port DS3 IMA Module Description and Technical Specifications Page 1 of 8 Part Number: 527M0A0001Z2 Document Number: 255-700-423

Safety Information When installing and operating the 1-Port DS3 IMA module, follow the safety guidelines provided in the PacketStar PSAX Safety Guidelines, which accompanies this product, to help prevent serious personal injury and damage to the module. Please read all warnings and instructions supplied before beginning installation or configuration of this module. In addition to the general safety information provided, you should also refer to the text in the PacketStar PSAX installation guides for other important safety information and procedures. Hardware Specifications Supported The 1-Port DS3 IMA module provides the following hardware features: Front-End: DMA interface with one physical port Number of ports: one Port density: 28 virtual channels Connector type: two BNC connectors, one to receive data and one to transmit data Line rate: 44.736 Mbps Bandwidth: 1.544 to 44.736 Mbps Description of the Module Functional Description The 1-Port DS3 IMA (Inverse Multiplexing over ATM) module combines the features of the 1-Port Channelized DS3 Multiservice module (see the PacketStar PSAX 1-Port Channelized DS3 Multiservice Module User Guide) and the 6-Port DS1 IMA module (see the PacketStar PSAX 6-Port DS1 IMA Module User Guide). It allows you to configure up to 28 virtual T1 ports for native DS1 ATM services or for as many as 14 independent IMA groups. This gives you point-to-point bandwidth options between that of a single T1 line and that of a T3 line. Hardware Specifications Table 1. Physical Hardware Specifications Table 1 provides the general physical hardware and environmental specifications for the PacketStar PSAX I/O and server modules. Dimensions Specification Weight Operating temperature range for AC-powered PSAX 1000 and all PSAX 1250, PSAX 2300, and PSAX 4500 systems Operating temperature range for DC-powered PSAX 1000 systems Description 17.3 cm H x 2.41 cm W x 24.1 cm D (6.8 in. H x 0.95 in. W x 9.5 in. D) 0.45 kg (1.0 lb.) 0 to 50 C (32 to 122 F) -20 to 60 C (-4 to 140 F) with a cold start minimum of 0 C (32 F) Page 2 of 8 1-Port DS3 IMA Module Description and Technical Specifications

Table 1. Physical Hardware Specifications (Continued) Specification Description Operating humidity range 5% to 85% relative humidity Operating altitude range 197 feet below sea level to 13,123 feet above sea level Storage temperature range -40 to 70 C (-40 to 158 F) Storage humidity range 0 to 90% noncondensing Performance and Power Specifications Table 2 provides the chassis speed, power consumption, and memory allocation specifications for this module. Table 2. Performance and Power Specifications for the 1-Port DS3 IMA Module Module 1-Port DS3 IMA (DS3 IMA) Total Amount of SDRAM Module Program and Data Space Maximum Input Buffer * Output Buffer 24 MB 7 MB 4 MB 13 MB (212,992) Chassis Speed Low Speed Maximum Power Consumption 13 W * The I/O buffers carry 16,384 cells per megabyte. Indicates the size of the output buffer followed by the maximum number of 64-byte cells in the output buffer. This column relates only to the speed at which the module communicates within the chassis. A high-speed module will communicate at high speed (1.2 Gbps) in a chassis that has a high-speed bus (PSAX 4500 chassis). High-speed modules will communicate at 600 Mbps in any other chassis. Low-speed modules will always communicate at 600 Mbps in any chassis. Module Placement The 1-Port DS3 IMA module is installed in any PSAX chassis slot intended to contain an I/O or server module. If you are installing the module in a newly installed PSAX chassis, be sure to follow your facility site plan for placing this module in the correct location in the chassis. Installing the Module Read the PacketStar PSAX Safety Guidelines, which accompanies this product, before proceeding.! WARNING: Be sure to use the ejector handles during installation and removal of a PSAX module.! WARNING: Make sure the locking tab at the bottom of the module (looking at module in a vertical position) is UP before you insert it into the chassis. 1-Port DS3 IMA Module Description and Technical Specifications Page 3 of 8

! WARNING: When inserting modules into the chassis, slide them gently, not forcefully. Excessive force may cause the modules to be seated improperly in the chassis, and result in possible damage to the module or the chassis. Install or remove modules one at a time. Doing this aids in preventing the PSAX system from indicating any erroneous failure messages, and allows the PSAX system time to reinitialize and display the accurate configuration of the module that is inserted. Begin 1 Remove the module from its box and ESD protective bag only when you are ready to install it. Be sure to save the box and the ESD bag to ship the module in the future if needed. 2 Open the ejector handle at the top of the module faceplate, and slide the module into an available slot. Be sure to position the module with the ejector handle near the top edge of the chassis opening on the PSAX 1250, PSAX 2300, and PSAX 4500 chassis. Position the module horizontally in the PSAX 1000 chassis with the ejector handle to the left. 3 Press the ejector handle until it snaps firmly against the faceplate, and verify that the module is secure in its slot. 4 Insert a flathead screwdriver into the screwdriver slot of the locking tab, and slide the locking tab down into the locking tab slot (see Figure 2). Note: Engage the locking tab on modules in the PSAX 1000, PSAX 2300, or PSAX 4500 chassis. Use of the locking tab is not required for the PSAX 1250 chassis. 4 Figure 2. Locking Tab on the I/O Module Faceplate (Shown in a PSAX 4500 Chassis) 5 For new installations, run the cabling through a cable management system that provides the necessary connector/cable strain relief to prevent damage to the I/O module connectors. Page 4 of 8 1-Port DS3 IMA Module Description and Technical Specifications

! WARNING: To prevent any damage to the I/O module connectors, do not allow network cables to hang unaided from the connectors. Use standard cable installation procedures to run and secure the network cables through an appropriate cable management system before connecting the cables to the I/O modules. End Verifying the Initial Startup After you insert the 1-Port DS3 IMA module into the chassis, observe the LED status indicators as described in Table 3. If the status indicators do not appear to function properly, refer to Troubleshooting the Installation on page 7. Table 3. LED Indicators for the 1-Port DS3 IMA Module LED FAIL (red) Module Status ACTIVE (green) LOS [Loss of Signal] (yellow) Initial Power-On No Configured Ports One or More Configured Ports Lights briefly 1 Not lit Lights only when the module is not functioning Lights briefly 1 Not lit Lights only when the module is functioning properly No Cable on Port N/A N/A Cable on Port N/A N/A Lights briefly 2 N/A N/A Lights Does not light if signal is being received Lights if signal is missing 1 Note: After power is initially applied to the system and the system boot is complete, the FAIL and ACTIVE LEDs indicate whether the module has no configured ports (red), or one or more configured ports (green). 2 Note: After power is initially applied to the system and the system boot is complete, this loss of signal LED indicates whether the port has a cable connected to it. 1-Port DS3 IMA Module Description and Technical Specifications Page 5 of 8

Removing the Module Read the PacketStar PSAX Safety Guidelines, which accompanies this product, before proceeding.! WARNING: Be sure to use the ejector handles during installation and removal of a PSAX module. 1 Disconnect the cables from the module port (or ports). 2 Insert a flathead screwdriver into the screwdriver slot of the locking tab, and slide the locking tab up and out of the locking tab slot (see Figure 3). 4 Figure 3. Locking Tab on the Module Faceplate (Shown in a PSAX 4500 Chassis) 3 Pull backward on the ejector handle until the module is released from the backplane. 4 Remove the module from the chassis. 5 Put the module in its ESD bag, close the bag, and place the module in its original shipping box. 6 If another module is not being immediately inserted into the empty slot, insert a blank faceplate module into the slot to prevent electromagnetic interference (EMI) and maintain proper air flow inside the chassis.! CAUTION: Ultimate disposal of this product should be handled according to all laws and regulations in your specific geographic region. End Page 6 of 8 1-Port DS3 IMA Module Description and Technical Specifications

Configuring the Module For information on configuring the ports and channels, interfaces, and connections for this module, see the Product Information Library CD-ROM that accompanied your PSAX Multiservice Media Gateway system software shipment. You can also separately order a printed copy of the PacketStar PSAX 1-Port DS3 IMA Module User Guide from the Lucent Technologies Customer Information Center Web site at: http://www.lucentdocs.com. Troubleshooting the Installation If you experience a problem with the 1-Port DS3 IMA module, refer to the Lucent Technologies Product Warranty Registration Information, which accompanied your shipment, for instructions on obtaining support in your area. Regulatory Standards Compliance Safety and Electromagnetic Compatibility (EMC) The following PacketStar PSAX systems are compliant with applicable safety and EMC standards when configured with the 1-Port DS3 IMA module (model 23N68): PSAX 1000 system PSAX 1250 system PSAX 2300 system PSAX 4500 system Please refer to the PacketStar PSAX 1000, PSAX 1250, PSAX 2300, or PSAX 4500 Multiservice Media Gateway installation guide for details on safety and EMC standards compliance. 1-Port DS3 IMA Module Description and Technical Specifications Page 7 of 8

The information in this document is for informational use only, is subject to change without notice, and should not be construed as a commitment by Lucent Technologies, Inc. This document is without warranty of any kind, either expressed or implied. Lucent Technologies, Inc. assumes no responsibility for any errors, inaccuracies, or omissions. Neither is any liability assumed for damages resulting from the use of the information or instructions contained herein. Lucent Technologies, Inc. is not responsible for any damage or loss to your data or equipment resulting either directly or indirectly from use of this document. Lucent Technologies has made a commitment to reduce the environmental impact of its products by reusing and recycling material. In keeping with this commitment, this document is printed on paper containing 100% recycled paper. We encourage you to support the principle of reduction, reuse, and recycling of materials by recycling this product when it is no longer needed. Copyright 2003 Lucent Technologies All rights reserved. Printed in the USA. Part Number: 527M0A0001Z2