Undulators at PETRA: Experience and Perspectives



Similar documents
Damping Wigglers in PETRA III

Undulators and wigglers for the new generation of synchrotron sources

A Quick primer on synchrotron radiation: How would an MBA source change my x-ray beam. Jonathan Lang Advanced Photon Source

ESRF Upgrade Phase II: le nuove opportunitá per le linee da magnete curvante

Information about the T9 beam line and experimental facilities

Lecture VI Magnetic Design

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Insertion Devices Lecture 4 Permanent Magnet Undulators. Jim Clarke ASTeC Daresbury Laboratory

Robot Perception Continued

Catherine LeCocq, Robert Ruland. February, 2008

Practical Alignment Tools and Techniques

E190Q Lecture 5 Autonomous Robot Navigation

The half cell of the storage ring SESAME looks like: Magnetic length =

Cross-beam scanning system to detect slim objects. 100 mm in

Digital vs. Analogue Control Systems

Brookhaven Magnet Division - Nuclear Physics Program Support Activities

Zero Degree Extraction using an Electrostatic Separator

SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II

Measurement of Charge-to-Mass (e/m) Ratio for the Electron

Development of Radiation Resistant Quadrupoles Based on High Temperature Superconductors for the Fragment Separator

Shielding and Radiation Measurements at ESRF

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

ENGINEERING METROLOGY

International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters

CALIBRATION OF A ROBUST 2 DOF PATH MONITORING TOOL FOR INDUSTRIAL ROBOTS AND MACHINE TOOLS BASED ON PARALLEL KINEMATICS

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

5-Axis Test-Piece Influence of Machining Position

BB-18 Black Body High Vacuum System Technical Description

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

National Performance Evaluation Facility for LADARs

FORCE ON A CURRENT IN A MAGNETIC FIELD

Cathode Ray Tube. Introduction. Functional principle

PCB Component Placement Inspection

Vector Network Analyzer Techniques to Measure WR340 Waveguide Windows

Making Better Medical Devices with Multisensor Metrology

A METHOD OF CALIBRATING HELMHOLTZ COILS FOR THE MEASUREMENT OF PERMANENT MAGNETS

HIGH PRODUCTION DUAL DRIVE HORIZONTAL MACHINING CENTER

The accurate calibration of all detectors is crucial for the subsequent data

Prelab Exercises: Hooke's Law and the Behavior of Springs

Wir schaffen Wissen heute für morgen

Bar Code Label Detection. Size and Edge Detection APPLICATIONS

WOOD WEAR TESTING USING TRIBOMETER

Products. Air Bearing- Linear systems EITZENBERGER. Luftlagertechnik GmbH. Feichtmayrstraße 17 D Wessobrunn

COMBIMASS. Technical Data COMBIMASS eco-bio +

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

High Performance Visible Laser Diode Scanners

Review Questions PHYS 2426 Exam 2

ELECTRIC FIELD LINES AND EQUIPOTENTIAL SURFACES

Magnetic Field and Magnetic Forces

Status of the Free Electron Laser

Series: IDAM Servo Drive E Digital Motor Drive - DMD

[ means: Save time, money and space! MAXXMILL 500. Vertical milling center for 5-side machining

Collision Prevention and Area Monitoring with the LMS Laser Measurement System

Specifications for DRIVER S REAR VIEW CAMERA

Types of 3D Scanners and 3D Scanning Technologies.

Precise heavy-duty cutting

Three Channel Optical Incremental Encoder Modules Technical Data

Fraunhofer Diffraction

Atomic Force Microscope

Atomic Force Microscope and Magnetic Force Microscope Background Information

Traffic Monitoring Systems. Technology and sensors

Module 13 : Measurements on Fiber Optic Systems

Status of the SOLEIL project Commissioning from Linac to beamlines

DUGARD. Machine Tools Since Dugard 400 Slant Bed High Precision CNC Lathe.

Development of on line monitor detectors used for clinical routine in proton and ion therapy

Synthetic Sensing: Proximity / Distance Sensors

Electromagnetic Compatibility Test Report Test results of Floww equipment

Short overview of TEUFEL-project

Alternative Linear Motion Systems. Iron Core Linear Motors

Testing thermo-acoustic sound generation in water with proton and laser beams

How To Use An Ionsonic Microscope

IP-S2 Compact+ 3D Mobile Mapping System

3D laser removal and texturing in a new dimension

Solar Tracking Application

SUN SIMULATION AT HIGH FLUX LEVEL

MEASURING AND LEVELING TOOLS

Index-Velocity Rating Development for Rapidly Changing Flows in an Irrigation Canal Using Broadband StreamPro ADCP and ChannelMaster H-ADCP

Accurate Air Flow Measurement in Electronics Cooling

Soil degradation monitoring by active and passive remote-sensing means: examples with two degradation processes

Active Vibration Isolation of an Unbalanced Machine Spindle

DUGARD. Machine Tools Since Dugard ECO Series Driven Tool, Slant Bed CNC Lathes.

Mark Jaski. Multi-Bend-Achromat (MBA) Magnets

Newland Machine Tool Group Inc.

DMS 680. Universal length measuring system gauge inspection for»iso 9000«requirements

CNC HARDWARE & TOOLING BASICS

HIGH SPEED PERMANENT MAGNET SYNCHRONOUS MOTOR / GENERATOR DESIGN FOR FLYWHEEL APPLICATIONS

DRS-6/1 Doppler Radar Sensor

TA-A BED TYPE MILLING CENTRE

PoS(PhotoDet 2012)068

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

MoveInspect HF HR. 3D measurement of dynamic processes MEASURE THE ADVANTAGE. MoveInspect TECHNOLOGY

Givare NC-SRS 280 och 880

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

A new extraction system for the upgraded AIC-144 cyclotron

Modern Physics Laboratory e/m with Teltron Deflection Tube

TENSIONMETER ** code 183_LNRSTW **

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Transcription:

Undulators at PETRA: Experience and Perspectives Markus Tischer for the Insertion Devices Group at DESY 3-Way Meeting, Argonne, Aug 1 st - 2 nd 2013

Outline > PETRA III IDs > Commissioning experience > Radiation Damage Issues > PETRA III Extension IDs Coworkers: A. Schöps, G.Naulin P. Vagin, S. Tripathi, O. Zeneli P. Neumann, T. Vielitz, T. Cheung M. Tischer 3-Way Meeting, 01.08.2013 Page 2

Parameters and Spectral Performance of PETRA III Undulators U29_5m U29 U32 U23 UE65 * U19 U32_10m Minimum magnetic gap [mm] 9.5 9.5 9.5 9.5 11.0 7.0 12.5 Period length λ U [mm] 29 29 31.4 23 65.6 19 31.4 Length L [m] 5 2 2 2 5 4 10 Periods 168 67 61 84 72 204 154 Peak field B 0 [T] 0.81 0.81 0.91 0.61 1.03 0.7 0.68 Deflection parameter K max 2.2 2.2 2.7 1.3 6.3 1.24 2.0 1st Harmonic E 1 [kev] 3.5 3.5 2.4 8.0 0.3 10.1 3.6 Total power P tot [kw] 7.5 3.0 3.8 1.7 11.8 4.5 10.7 On-axis power dens. [kw/mrad 2 ] 190 76 80 71 0.17 200 300 Power in 1x1mm 2 at 40m [W] 119 47 49 44 0.1 122 185 High-β source (10keV) size : 140 x 5.6 µm 2 divergence : 7.9 x 4.1 µrad 2 Low-β source (10keV) size : 36 x 6.1 µm 2 divergence : 28 x 4.0 µrad 2 * in helical mode M. Tischer 3-Way Meeting, 01.08.2013 Page 3

Operation Experience at PETRA III > Only small closed orbit distortions Corrected by air coils (CODs ±20 / ±5µm (horiz./vertical) No problems with injection at closed gap > Gap dependent pointing direction Some very sensitive experiments required sub-µrad corrections to assure pointing accuracy > Tune shift of UE65 (APPLE2) 3kHz, 0.5kHz (horiz., vertical), shift dependent 3x reduced by dynamic multipole shims Further reduction possible by feed-forward (not needed at present) > Radiation Damage at several undulators Known since quite a while M. Tischer 3-Way Meeting, 01.08.2013 Page 4

Radiation Damage Issues > Summary of previous observations High dose rate in the tunnel (~kgy per 5 weeks on TLDs) Damaged components (several motor and linear encoders at IDs, various other electronics) 10000 Dosis within 1 run [Sv] 1000 100 10 PETRA III ID Dosis "New Oktant" assorted selection of different run periods (~4-5 weeks) 2012_6 2013_3 2013_4 SE PU01SA PU01SE PU02SE PU03SA PU03SE PU04SA PU04SE PU05SE PU06SA PU06SE PU07SA PU07SE PU08SE PU09SA PU09SE PU10SA PU10SE PU11SE PU12SA PU12SE PU13SE PU14SA PU14 PU01 PU07 PU14 300 PETRA III Dose Rate "Undulators in New Octant" (starting at installation date of particular ID) Grand Total [ksv] 250 200 150 100 50 0 M. Tischer 3-Way Meeting, 01.08.2013 Page 5 PU01 PU07 PU14 SE PU01SA PU01SE PU02SE PU03SA PU03SE PU04SA PU04SE PU05SE PU06SA PU06SE PU07SA PU07SE PU08SE PU09SA PU09SE PU10SA PU10SE PU11SE PU12SA PU12SE PU13SE PU14SA PU14

Radiation Damage Issues > Summary of previous observations Strong dependence of dose rate as function of vertical angle through the upstream dipole (SR) Corrosion of magnet structure due to radiochemistry (humidity problem solved) BeamLossMonitors (pin diodes) were installed at all IDs as online-diagnostics (but not usable by normal shift operators) BLMs Dipole Absorber B (horizontal) Taper T (vertical) 9mm Undulators 7mm aperture 6m M. Tischer 3-Way Meeting, 01.08.2013 Page 6

Radiation Damage Issues Gap [mm] Undulator Gap of PU01 vs Time 14.3 tuning at E=14.4keV 14.25 14.2 14.15 14.1 14.05 PU01a 14 PU01b 13.95 01.06.10 01.06.11 01.06.12 01.06.13 Date Gap [mm] 10.2 10.15 10.1 10.05 10 Undulator Gap of PU02 vs Time tuning at E=60keV 9.95 01.01.11 01.01.12 01.01.13 01.01.14 Date Minimum Gap = 9.95 mm (Reached in December 2013) > Gap decrease for a desired energy Systematic decrease of gap for a particular energy over time Gap optimized for max. throughput for otherwise same beamline settings Observed at some beamlines which do not change the setup frequently M. Tischer 3-Way Meeting, 01.08.2013 Page 7

Radiation Damage Issues > Spectral Degradation Broadened undulator harmonics, even with satellites Intensity loss Spoiled line shape can only be partly cured by applying a taper At PU08: Upstream end suffered magnetization loss (corresponding to a negative taper for correction) Total intensity drop by at least a factor of 2 since installation 5 th harm. line shape for different taper at undulator PU08 M. Tischer 3-Way Meeting, 01.08.2013 Page 8

Radiation Damage Issues > Magnetic Measurements Performed in the tunnel at the installed ID Hall probe moved manually over the magnet structure in a carriage Comparison of peak field values Coarse measurement, but error bar below <0.2% M. Tischer 3-Way Meeting, 01.08.2013 Page 9

Radiation Damage Issues > Magnetic Measurements (cont d) Both 5m IDs at the beginning of the new octant (2012): M. Tischer 3-Way Meeting, 01.08.2013 Page 10

Radiation Damage Issues > BLMs using Cherenkov Radiation in optical fibers Present test-setup at 2 straight sections in PETRA (under construction) Well established system at FLASH IDs and other locations (e.g. DIPAC (2009) 411; EPAC (2008) 1032) Principle: Radiation shower is converted into Cerenkov light Detection by photomultiplier + counter and/or fast ADC ( dose rate) Position-sensitive Extremely high temporal resolution (depending on fiber length) Will allow to distinguish different operation states INTEGRATOR TIME MEASUREMENT PHOTODETECTOR IRRADIATION INTENSITY POSITION FIBER OPTICAL CABLE ACCELERATOR M. Körfer, 2001 > No consistent picture up to now Only particular IDs are affected No correlation to visible corrosion patterns TLD results do not match well to the damage locations BLM and TLD measurements agree only qualitatively mechanism not yet understood, but both electrons and SR are involved at different locations F.Wulf, M.Körfer, DIPAC (2009) 411 M. Tischer 3-Way Meeting, 01.08.2013 Page 11

Undulators for PETRA III Extension BL length period energy technique P61 10 x 4 m 200 mm 50-150 kev mater. sci., PDF P62 N = 12 Tbd 6-35 kev SAXS P63 N = 12 32 mm 3-44 kev micro XRF P64 2 m 32 mm 3-44 kev (Q)EXAFS P65 N = 12 32 mm 4-44 kev XAFS BL length period energy technique P21a 4 m IVU 50-200 kev mater. sci. P21b 2 m wiggler 50-200 kev imaging P21c 2 m 29mm ~100 kev mater. sci. P22 2 m tbd 3-50 kev nano XRF P23 2 m tbd 5-50 kev nano XRD P24 N = 12 tbd 8-40 kev (Q)EXAFS P25 N = 12 tbd tbd education ID access Vehicle for undulator transport in the tunnel (several 100 meters) due to lack of crane access. M. Tischer 3-Way Meeting, 01.08.2013 Page 12

Undulators for PETRA III Extension > Boundaries for ID design, transport, operation Various obstacles for transport in the present tunnel (existing installations, cable trays, doors, steps) Different beam height in the new arcs (1400mm) and in the old tunnel (~1.2m) need for 2 different support structures Temperature control: ~slim concept with potential for upgrade > Undulator design Same concept for FLASH II and PETRA Extension IDs Various mechanical improvements (stiffness, adjustment, floor mount) Revised drive system: 2 motors and 2 pairs of left/right-handed spindles Additional chamber touch sensors New linear encoder gap measurement system M. Tischer 3-Way Meeting, 01.08.2013 Page 13

Linear Encoder Systems (FLASH II) Rotary motor encoders - systematic deviation reflects magnetic forces, compensated by feed-forward correction - resulting accuracy below 10µm, i.e. very precise drive mechanics Linear encoders - different versions built & tested - open Renishaw system - hysteresis reduced to less than 1µm - reproducibility is much better (sub-µm) 1 µm M. Tischer 3-Way Meeting, 01.08.2013 Page 14

Undulators for PETRA III Extension > Developments for magnetic measurements and tuning Touch probe measurement of pole contour 3D metrology with the measurement bench for mechan. characterization and transfer measurements Investigation of Hall probe calibration errors, wire probe etc. Use additional pole movements for correction of higher order magnetic errors > Improved tuning results for FLASH II IDs Reduced phase error Enhanced trajectory straightness Smaller gap dependence of field integrals Local correction of quadrupole errors Beneficial improvements in particular for P3 extension IDs M. Tischer 3-Way Meeting, 01.08.2013 Page 15

Undulator Source for EXAFS > EXAFS requires frequent scanning of the energy, i.e. gap! Tapered Undulator? > Tapered Undulator: Spatial distribution changes with energy! M. Tischer 3-Way Meeting, 01.08.2013 Page 16

Undulator Source for EXAFS > Simulated EXAFS with Tapered Undulator Inhomogeneous test sample: - Zn-K edge = 9669 ev - Area: 700 µm x 700 µm - Gap: 350 µm µd I = ln I 0 = ln I 0 Courtesy of O.Müller, Univ. Wuppertal ( ) ( ) ( ) ( ) I0 E, x, y da µ E, x, y d x, y E, x, y e da Non-uniform illumination of an inhomogeneous sample large artefacts in the spectrum (show stopper) M. Tischer 3-Way Meeting, 01.08.2013 Page 17

Undulator Source for EXAFS > Real EXAFS Measurement with Tapered Undulator Courtesy of O.Müller, Univ. Wuppertal Undulator P06: - E Undulator = 10200 ev - Taper = 1 mm - λ U = 31.4 mm; L=2m - Source Distance = 90 m > Tapered spectrum shows sub-structure > XAFS spectra strongly depend on the orientation of the test sample > Tapered undulator is an inadequate source for (most) XAFS applications On-the-fly measurements with synchronized monochromator and undulator > Wiggler not possible due to power restrictions, short wiggler M. Tischer as bad 3-Way Meeting, as tapered 01.08.2013 undulator Page 18

Energy Scan Monochromator vs. Undulator > Energy Scan 20 ev / sec (und. velocity control OK) > Preliminary tests very promising, next: Include the undulator velocity control in a TANGO device Treat undulator gap as slave of the Bragg axis Feeding the Bragg-encoder signals directly into the undulator NC (still the previous status) A. Schöps G. Wellenreuther M. Tischer 3-Way Meeting, 01.08.2013 Page 19

Damping Wigglers for PETRA III Extension PU61 92m Damping section North 6 m long final absorber M. Tischer 3-Way Meeting, 01.08.2013 Page 20

Damping Wigglers: Parameters Magnet structure Peak field B 0 1.52 T Magnetic gap 24 mm Period length 0.2 m Number of poles 38 + 2 ½ Magnet volume / period 2200 cm 3 Field quality at x 0 = 10 mm < 10 3 Damping integral / segment 3.9 T 2 m SR characteristics SR critical energy 35.8 kev K -Parameter 28.4 Wiggler SR power* 21 kw Vertical SR spread 170 µrad Horizontal SR spread 4.84 mrad * I=100mA Overall length / segment 3.97 m Number of wiggler segments (West + North) 10 + 10 NdFeB magnets built in collaboration with BINP Proceedings EPAC08, Genoa (2008) 2317 B r = 1.3T H cj = 1430kA/m (17.9kOe) M. Tischer 3-Way Meeting, 01.08.2013 Page 21

Damping Wigglers: Magnetic Design End plate Pole Long. magnet Non-magnetic spacer Side magnet Iron yoke Corrector bolt Iron yoke Wedged poles 290 Modified hybrid structure Wedge-shaped iron poles also powered by side magnets Iron enclosure Magnetic yoke Mechanical support Iron spacer 262 Aluminium spacer Zero potential surface Axial magnets split into 2 halves by soft iron V-notches sitting on the yoke almost no cross talk between poles M. Tischer 3-Way Meeting, 01.08.2013 Page 22

Conclusion > PETRA III Reliable operation of all IDs Several magnet structures suffer from radiation damage; investigation will continue IVU for PU07 in 2014 > PETRA Extension IDs ID parameters ~specified, construction partly started, even more safety margin needs to be included in the magnet design IVU for PU21 EXAFS-IDs shall be undulators > Measurement Lab Assembly and tuning of 12 SASE IDs for FLASH II presently ongoing In this context, improvements and extensions of calibration and measurement techniques and also tuning procedures M. Tischer 3-Way Meeting, 01.08.2013 Page 23