M5 line User Manual M.I.U.M5-4/03.01 Cod. J AM5 IE
|
|
|
- August Wood
- 10 years ago
- Views:
Transcription
1 Process Controller with Programmer 1 / 16 DIN - 48 x 48 ASCON spa ISO 9001 Certified M5 line c User Manual M.I.U.M5-4/03.01 Cod. J AM5 IE C UL US LISTED ASCON spa Bollate (Milano) Italy via Falzarego, 9/11 Tel Fax [email protected]
2 Process Controller with Programmer 1 / 16 DIN - 48 x 48 M5 line c C UL LISTED US REM SP 1 SP 2 A / M RUN MAN 48.50
3 Indications c NOTES ON ELECTRIC SAFETY AND ELECTROMAGNETIC COMPATIBILITY Please, read carefully these instructions before proceeding with the installation of the controller. Class II instrument, real panel mounting. This controller has been designed with compliance to: Regulations on electrical apparatus (appliance, systems and installations) according to the European Community directive 73/23/EEC amended by the European Comunity directive 93/68/EEC and the Regulations on the essential protection requirements in electrical apparatus EN : 93 + A2:95. Regulations on Electromagnetic Compatibility according to the European Community directive n089/336/eec, amended by the European Community directive n 92/31/EEC, 93/68/EEC, 98/13/EEC and the following regulations: Regulations on RF emissions EN : 2001 industrial environments Regulation on RF immunity EN : 2001 industrial equipment and system It is important to understand that it s responsibility of the installer to ensure the compliance of the regulations on safety requirements and EMC. The device has no user serviceable parts and requires special equipment and specialised engineers. Therefore, a repair can be hardly carried on directly by the user. For this purpose, the manufacturer provides technical assistance and the repair service for its Customers. Please, contact your nearest Agent for further information. All the information and warnings about safety and electromagnetic compatibility are marked with the B sign, at the side of the note. 2
4 Table of Contents TABLE OF CONTENTS 1 INTRODUCTION...PAGE PRODUCT CODING...PAGE 5 2 INSTALLATION...PAGE DESCRIPTION...PAGE OPERATING CONDITIONS...PAGE INSTALLATION...PAGE 7 3 ELECTRICAL CONNECTIONS...PAGE TERMINATION UNIT...PAGE CABLING LAYOUT...PAGE ELECTRICAL CONNECTIONS...PAGE 9 4 OPERATIONS...PAGE FRONT PANEL...PAGE CONFIGURATION...PAGE PARAMETER SETTING...PAGE ACCESS LEVELS...PAGE 27 5 DISPLAYS...PAGE 29 6 COMMANDS...PAGE COMMANDS FROM KEYBOARD...PAGE COMMANDS FROM DIGITAL INPUTS...PAGE COMMANDS FROM SERIAL COMMUNICATION (PLEASE, REFER THE ADDENDUM ON THE SERIAL COMMUNICATION) 7 SETPOINT PROGRAMMER ( OPTIONAL )...PAGE PROGRAM ORGANISATION...PAGE OPERATING CONDITIONS...PAGE PROGRAM INPUT AND EDITING...PAGE RUN/STOP OF A PROGRAM...PAGE 38 8 TECHNICAL SPECIFICATIONS...PAGE 39 3
5 1 - Introduction 1 INTRODUCTION POWERFUL FEATURES AND A WIDE RANGE OF FUNCTIONALITIES Congratulations for having chosen these universal controllers. They are the best result of our experience in designing and manufacturing of smart, powerful and high reliable controllers. The process controllers of the M5 series have been designed for the industrial environment, are provided with a complete set of functions, as a true universal instrument. They can be used as Controllers- Programmers with 1 profile of 16 segments. Resources Operating mode Main universal input PV Memory Chip Data Copy/Data Store (option) OP1 Control Alarms Retransmission PV/SP 1 Single OP1 OP2 OP3 OP4 action Auxiliary input (option) Two digital inputs AUX IL1 IL2 M5 OP2 OP3 OP4 (option) 2 Single OP4 OP1 OP2 OP3 action 3 Double OP1 OP2 OP3 OP4 action 4 Double OP1 OP4 OP2 OP3 action 5 Double OP4 OP2 OP1 OP3 action 6 Valve OP1 OP2 OP3 OP4 Digital inputs (IL1, IL2) functions Modbus RS485 Parameterisation Supervision (option) Tuning One shot Auto tuning Adaptive 4
6 1.1 PRODUCT CODING The complete code is displayed on the instrument label. The information about product coding are accessible from the front panel by mean of a particular procedure described at section 5.1 pag 29 P/N ; M CONF : S/N : A0A-9809/0011 V~(L-N) V 50/60 Hz - 3W Model: Line Model Basic Accessories M5 A B C D E F G Power Supply Outputs Serial comm.s/options 1 - Introduction Colour Instruction handbook Power Supply A V~ (- 15% + 10%) 3 24V~ (- 25% + 12%) or 24V (- 15% + 25%) 5 0 Instrument label REM SP 1 SP 2 A / M 3150 RUN MAN Hard Outputs OP1 (OP2) B Relay - Relay 1 Relay - Triac 2 Triac - Relay 4 Triac - Triac 5 Serial Comms. Not fitted RS485 Modbus/Jbus protocol Options C D None [2] 0 0 Auxiliary Feedback potentiometer [2] 0 1 Remote [1] 0 2 Input Current Transformer 0 3 Auxiliary SSR drive/analogue 0 4 Output SSR drive/analogue + Remote [1] [2] 0 5 None [2] 5 0 Auxiliary Feedback potentiometer [2] 5 1 Remote [1] 5 2 Input Current Transformer 5 3 SSR drive/analogue auxiliary output 5 4 [1] Not available with programmer installed (E = 1) [2] Second digital input (IL2) not available B C D Basic product code Programmer E Not fitted 0 Fitted 1 Instruction handbook F Italian-English (std) 0 French-English 1 German-English 2 Spanish-English 3 Front panel Colour G Dark (std) 0 Beige 1 5
7 2 - Installation 2 INSTALLATION Installation must only be carried out by qualified personnel. 2.1 INSTALLATION DESCRIPTION IP 20 Termination Unit EN (IEC1010-1) DIMENSIONAL DETAILS 48 mm 1.89 in Before proceeding with the installation of this controller, follow the instructions illustrated in this manual and, particularly the installation precautions marked with the B symbol, related to the European Community directive on electrical protection and electromagnetic compatibility. Memory Chip connector Panel surface 20 mm max 0.79 in max 48 mm 1.89 in B To prevent hands or metal touching parts that may be electrically live, the controllers must be installed in an enclosure and/or in a cubicle. 150 mm 5.9 in Product code label PANEL CUT-OUT 65 mm min 2.56 in min Mounting Clamps Sealing front panel gasket Front Panel IP65 protection EN (IEC 529) mm in 65 mm min 2.56 in min mm in
8 2.2 ENVIRONMENTAL RATINGS B Operating Conditions M T %Rh Altitude up to 2000 m Temperature 0 50 C Relative Humidity 5 95 %Rh non-condensing 2.3 PANEL MOUNTING [1] INSERT THE INSTRUMENT 1 Prepare panel cut-out 2 Check front panel gasket position 3 Insert the instrument 1 through the cut-out 2 - Installation INSTALLATION SECURING 1 Fit the mounting clamps 2 Push the mounting clamps towards the panel surface to secure the instrument 1 Special Conditions M T %Rh P Altitude > 2000 m Temperature >50 C Humidity > 95 %Rh Forbidden Conditions D C E Suggestions Use 24V~ supply version Use forced air ventilation Warm up Conducting atmosphere Use filters Corrosive atmosphere Explosive atmosphere CLAMPS REMOVING 1 Insert the screwdriver in the clips of the clamps 2 Rotate the screwdriver INSTRUMENT UNPLUGGING B 1 Push and 2 Pull to remove the instrument Electrostatic discharges can damage the instrument Before removing the instrument the operator must discharge himself to ground MΩ 1 1 UL note [1] For Use on a Flat Surface of a Type 2 and Type 3 raintight Enclosure
9 3 - Electrical Connections 3 ELECTRICAL CONNECTIONS 8 PRECAUTIONS B Despite the fact that the instrument has been designed to work in an harsh and noisy environmental (level IV of the industrial standard IEC 801-4), it is strongly recommended to follow the following suggestions. A All the wiring must comply with the local regulations. The supply wiring should be routed away from the power cables. Avoid to use electromagnetic contactors, power relays and high power motors nearby. Avoid power units nearby, especially if controlled in phase angle Keep the low level sensor input wires away from the power lines and the output cables. If this is not achievable, use shielded cables on the sensor input, with the shield connected to earth. UL note [1] Use 60/70 C copper (Cu) conductor only. 3.1 TERMINATION UNIT [1] B 3.2 RECOMMENDED ROUTING OF WIRES B ,5 Nm Terminals Ø L Rear terminal covers mm 0.22 in Wire size 1 mm 2 (18 AWG Solid/Stranded) 18 screw terminals Option terminals Holding screw 0.5 Nm Positive screw driver PH1 Negative screw driver 0,8 x 4 mm Pin connector q 1.4 mm in max Fork-shape AMP Ø 5.5 mm in Stripped wire L 5.5 mm in B C A = Supply B = Relay/Triac Output C = Analog Inputs D = Serial Communication E = Auxiliary Inputs/Outputs F = Digital Inputs E L N D Conduit for supply and output cables F A B Conduit for low level sensor cables B C E L N D F A B
10 3 - Electrical Connections 3.3 TYPICAL INSTRUMENT WIRING (valve control) B OP3 18 V OUT NO ma V C TC A 4 b 5 B 6 RS C 9 10 RTD DIGITAL INPUT 2 100% 10 POT 11 0% 1 12 Option terminals OP4 (REM) CT NO 17 C 18 NO OP1 OP2 L N Supervisory RS485 Notes: 1] Make sure that the power supply voltage is the same indicated on the instrument. 2] Switch on the power supply only after that all the electrical connections have been completed. 3] In accordance with the safety regulations, the power supply switch shall bring the identification of the relevant instrument. The power supply switch shall be easily accessible from the operator. 4] The instrument is PTC protected. In case of failure it is suggested to return the instrument to the manufacturer for repair. 5] To protect the instrument internal circuits use: - 2 A~ T fuses for Relay outputs - 1 A~ T fuses for Triac outputs 6] Relay contacts are already protected with varistors. Only in case of 24 V ~ inductive loads, use model A D7 varistors (on request) Digital Input Commands PLC V~ Alarm Fuse 2A ~T [6] OP3 V~ Supply V ~ 8 PTC Power switch L N L N PV 2 wires transmitter A B B ma mv-v Tc Pt V C OP1 17 OP2 18 Fuse [5] [6] [6] V~ Fuse [5] Buffer relays Raise Lower M Positioner module 9
11 3 - Electrical Connections POWER SUPPLY B PV CONTROL INPUT B included PTC L N Switching power supply with multiple isolation and internal fuse Standard version: nominal voltage: V~ (-15% + 10%) Frequency 50/60Hz Low Voltage version: Nominal voltage: 24V~ (-25% + 12%) Frequency 50/60Hz or 24V (-15% + 25%) Power consumption 3Wmax 150Ω/lead maximum A b B When using a 2 wire system, put a jumper between terminals 5 and 6 A For J L T K S R thermocouple type Use always compensation cable of the correct type for the thermocouple used Use always compensation cable of the correct type for the thermocouple used The shield, if present, must be connected to a proper earth. B For PT100 resistance thermometer If a 3 wire system is used, use always cables of the same diameter (1mm 2 min). Maximum resistance/line 20 Ω If a 2 wire system is used, use always cables of the same diameter (1.5mm 2 min). A When the distance between the controller and the sensor is 15 meters, using a cable of 1.5mm 2 diameter, produces an error in the measure of 1 C. R1 R2 A B A B1 For T (2x Pt100) Use wires of the same length. Maximum resistance/line 20 Ω. R1 + R2 must be <320Ω 10
12 3 - Electrical Connections PV CONTROL INPUTS (cont.) B AUXILIARY INPUTS (OPTION) B ma mv-v 5 6 Rj C For DC input Input resistance = 30Ω for ma Input resistance = 10MΩ for mv Input resistance = 10KΩ for Volt watt burden resistor 0.5Ω for 1A secondary transformer coil 0.1Ω for 5A secondary transformer coil 50/100mA CT load ~ A A For current transformer CT for the measure of the load current Primary coil 10A 100A Secondary coil 50 ma default 100mA jumper selectable PV ma Transmitters Transmitters PV ma Rj Rj 18V 18V C1 For 2 wires transmitters Power supply to the transmitter 18V ±10% 30mA max Input resistance = 30Ω C2 For 3 or 4 wires transmitters Power supply to the transmitter 18V ±10% 30mA max Input resistance = 30Ω Jumper for 100 ma secondary transformer coil Option Module for CT 11
13 3 - Electrical Connections AUXILIARY INPUTS (cont.) B OP1 OP2 OP3 AND OP4 OUTPUTS B e If the analogue input is provided, the terminals for the Remote are 10(+) and 9(-) Rj mv-v ma 100% 0% B From Remote Current 0/4 20mA Input resistance = 30Ω Voltage 1 5V, 0 5V, 0 10V Input resistence = 300KΩ C From Position Potentiometer To read the real position of the motor or the valve 100% From 100Ω to 10KΩ max DIGITAL INPUTS B 0% pot.h pot.i Operating Travel distance Total travel distance The functionality associated to each of the OP1 OP2 OP3 and OP4 outputs is defined during the configuration of the instrument. The possible choices are: where: Single action Single action Double action Double action Double action Valve Control OP1 Heat OP4 Heat OP1 Heat OP1 Heat OP4 [1] Heat OP1 Raise OP2 Cool OP4 [1] Cool OP2 Cool OP2 Lower Alarms Retransm. PV-SP OP2 OP3 OP4-C OP1 OP2 OP3 OP1 [2] OP2 [2] OP3 OP3 OP3 OP3 OP4-C OP4-C IL 1 IL 2 Com C1 C2 Isolated contact NPN open collector TTL open collector The associated function is active when the digital input is ON (see table on page 33) The second digital input (IL2) is available only with the following options: Remote (D = 2) Current transformer (D = 3) SSR drive / analogue output (D = 4) OP1 - OP2 OP3 OP4 OP4-C Relay or Triac output Relay output Analogue or SSR drive output Analogue output Note [1] In case of OP4 analogue output, its status is not visualised by any red led [2] When the OP4 SSR drive output is selected, the status of OP1 and OP2, as alarms, is not displayed by any red led 12
14 3 - Electrical Connections A SINGLE RELAY OUTPUT (TRIAC) B B SINGLE SSR DRIVE OUTPUT (OPTION) B F HEAT COOL OUTPUT RELAY (TRIAC)/SSR DRIVE (OPTION) B 16 OP1 17 Load V~ 11 OP4 12 Load V~ 16 OP1 17 Load Heat V~ 11 OP4 12 Cool Load V~ 1 NO contact Output 0 22V ±20% (20mA max) galvanic isolated C SINGLE ANALOGUE OUTPUT (OPTION) B D VALVE OUTPUT B G HEAT COOL OUTPUT SSR DRIVE (OPTION)/RELAY (TRIAC) B ma mv,v Load galvanic isolated 500 V~/ 1min 750Ω / 15V max if current output 500Ω / 20mA max if voltage output 16 OP1 17 OP2 18 Raise E HEAT COOL OUTPUT RELAY/RELAY (TRIAC/TRIAC) V~ Lower 3 pole output with NO contacts (raise, lower, stop) M ~ B 11 OP4 12 Heat Load V~ 17 OP2 18 Cool Load H HEAT COOL OUTPUT RELAY(TRIAC)/ANALOGUE (OPTION) B V~ 16 OP1 17 OP2 18 Load Heat V~ Cool Load 2 NO contacts 16 OP1 17 Load Heat V~ ma mv,v 11 OP4 12 Cool Load 13
15 3 - Electrical Connections I HEAT COOL OUTPUT DC (OPTION)/RELAY (TRIAC) B RETRANSMISSION OUTPUT (OPTION) B ma mv,v 11 OP4 12 Heat Load 17 OP2 18 Load Cool V~ ma mv,v Load galvanic isolated 500 V~/ 1min 750Ω / 15V max if current output 500Ω / 20mA max if voltage output e The analogue/ssr drive output OP4 can be used for signal retransmission only if it is not used as control output ALARM OUTPUTS OP1, OP2, OP3 B SERIAL COMMUNICATION (OPTION) B 16 OP1 17 OP NO contacts Load V~ Load e The relay/triac output OP1, OP2 and OP3, can be used as alarm outputs only if they are not used as control outputs Common Ground Galvanic isolation 500V~/1 min Compliance to the EIA RS485 standard for Modbus/Jbus A Please, read: gammadue and deltadue controller series serial communication and configuration V~ Load 1 2 OP3 1 NO contact 14
16 4 - Operation 4 OPERATION 4.1.A KEYS FUNCTION AND DISPLAY IN OPERATOR MODE 5 Status LED s (green): REM - Remote setpoint active SP1 - first stored setpoint active SP2 - second stored setpoint active RUN - program running MAN - manual operating mode 15 Parameter value Output status LED s (reds): OP1 output ON OP2 output ON OP3 output ON Parameter mnemonic Access to the menu for: - configuration - parameter setting - access definition Automatic/ manual PV measure in engineering units REM SP 1 RUN SP 2 MAN A / M Menu access REM SP 1 RUN SP 2 MAN A / M setting Parameter setting Entry key for selection and value setting confirmation 35.0 p.b. Operating (local/remote or stored) Run/stop of a program 4.1.B KEYS FUNCTION AND DISPLAY IN PROGRAMMING MODE Entry key for selection and value setting confirmation NUMERIC ENTRY (i.e. the modification of the value of a stored from to 240.0) Press $ or % momentarily to change the value of 1 unit every push. Continued pressing of $ or % changes the value, at rate that doubles every second. Releasing the button the rate of change decreases. In any case the change of the value stops when it has reached the max/min limit set for the parameter s.p. 2 lower 1100 s.p. 2 raise 1350 s.p. 2 2nd stored 2nd stored 2nd stored The new value is entered when the next parameter is selected by mean of the R key MNEMONIC SETTING (Way to modified configuration page 16 / 18) Press the $ or % to display the next or previous mnemonic for the selected parameter. Continued pressing of $ or % will display further mnemonics at a rate of one mnemonic every 0.5 seconds. The mnemonic displayed at the time the next parameter is selected, is the one stored in the parameter. C Unit. f Unit MA Unit ph Unit Centigrade Degrees Engineering Units Fahrenheit Degrees Engineering Units ma Engineering Units Ph Engineering units
17 4 - Operation 4.2 CONFIGURATION PROCEDURE Operator Conf Mode Menu Configuration menu Inp é0=10 Conf Inp. Inputs Configuration Input type see table 1 s.p. éloc Conf rs.p.c Configuration selection see Table 3 Press the key until é 0 sc.dd N of decimals (linear input only) 0 / 1 / 2 / 3 é4=20 rs.in Remote input (remote input only) see Table 4 Enter the configuration password from -999 to 9999 (33 as default from the factory) If the entered password corresponds to the value set in the parameter C.pas at pag. 27, proceed to YES 33 C.pas OK é 0 é9999 éno sc.lo sc.hi sqr Low range (linear input only) from min range up to sc.hi High range (linear input only) from sc.lo to max range Square root (linear input only) no / yes ép:sec s.p.tm Back to the 1st parameter s.p.=conf Time units and slope p.sec/ p.min /.phr If the configured hardware option is not installed, the display shows an hardware error message 100 H.Err NO YES 100 Analog output not installed Current trasformer not installed Remote input not installed Potentiometer input not installed 104 Analogue output + Remote not installed éno énone CHar Unit Back to the 1st parameter inp.=conf Linear inputs characterisation no / yes Engineering Units see table 2 16
18 CONFIGURATION MENU 4 - Operation Output Digital inputs Out L.inP AlM Conf Configuration Conf configuration Conf Alarm s configuration épid:r O.Ity Type of Control see Table 5 éoff Il1 IL1 function see Table 8 éoff Al.1 AL1 alarm type see Table 9 AL3 alarm type see Table 9 éoff éoff énone é4=20 é0 é9999 éoff H.C.OP s.out rth O.r.ty rt.lo rt.hi C.C.OP Heat control output see Table 6 Control output safety value Off/ % Retransmission output (available for DC output only) none / pu / s.p. Retransmission output type (available for DC output only) see Table 4 Retransmission low range whole range Retransmission high range whole range Cool control output see Table 7 Back to the 1st parameter of Out=Conf éoff Il2 Back to the 1st parameter of L.inp=Conf IL2 function see Table 8 éop1 éno éno éoff éop1 éno éno AI.Ou ltch bloc Al.2 A2.Ou ltch bloc AL1 addressing (not available when AL1 is OFF) OpI / Op2/ Op3 AL1 latching (not available when AL1 is OFF) no / yes AL1 start-up disabling (not available when AL1 is OFF) no / yes AL2 alarm type see Table 9 AL2 addressing (not available when AL2 is OFF) OpI / Op2/ Op3 AL2 latching (not available when AL2 is OFF) no / yes AL2 start-up disabling (not available when AL2 is OFF) no / yes éoff éop1 éno éno éoff éop1 éno Al.3 A3.Ou ltch bloc Al.4 A4.Ou ltch AL3 addressing (not available when AL3 is OFF) OpI / Op2/ Op3 AL3 latching (not available when AL3 is OFF) no / yes AL3 start-up disabling (not available when AL3 is OFF) no / yes AL4 alarm type see Table 9 AL4 addressing (not available when AL4 is OFF) OpI / Op2/ Op3 AL4 latching (not available when AL4 is OFF) no / yes AL4 start-up disabling (not available when AL4 is OFF) no / yes 17
19 4 - Operation EHit Conf Back to operator mode éno é100 éoff bloc Ht.f.C Ht.on Back to the 1st parameter AlM=Conf Output Configuration CT High range (available if at least one alarm is Htr) CT decimal point (available if at least one alarm is Htr) Off / On Tab. 1 Input type Value Description éinp. tc. j C F tc. l C F tc. K C F tc. s C F tc. r C F tc. t C F cust Custom range on request rtd C F rtd C F del.t C F MU 0 50 mv 0=5 0 5 Volt 1=5 1 5 Volt Engineering 0= Volt units 0= ma 4= ma Tab. 2 Engineering units Value Description éunit none None C Centigrade Degrees f Fahrenheit Degrees MA ma MU mv U Volt bar bar psi PSI rh Rh ph Ph Tab. 3 type Value Description érs.p.c. loc Local only rem Remote only l=r Local/remote only loc.t Local - trim rem.t Remote - trim Tab. 4 Rem. Retransmission Value Description 0=5 0 5 Volt 1=5 1 5 Volt 0= Volt 0= ma 4= ma érs.in éo.r.ty Tab. 5 Control type Value Description éoi.ty Of.re Reverse action On - Off Of.di Direct action pid.d Direct action P.I.D. pid.r Reverse action U.dir Direct action Modulating U.reU Reverse action valves H.C.ln Linear Heat/ H.C.Ol Oil charac. Cool H.C.H2 Water charac. Tab. 6 Heat control output Value Description éh.c.op Off Not used ri Relay 1 log SSR drive Digital signal 0=5 0 5 Volt 1=5 1 5 Volt Analogue 0= Volt signal 0= ma 4= ma Tab. 7 Cool control output Value Description éc.c.op Off not used r2 relay 2 log SSR drive Digital signal 0=5 0 5 Volt 1=5 1 5 Volt Analogue 0= Volt signal 0= ma 4= ma Tab. 8 Digital Inputs function éil1 Value Description éil2 Off Not used l=r Local/remote A.Man Auto/manual s.p.1 1st stored s.p.2 2nd stored keb.i Keypad slo.1 s.p. slope disable H.pU Measure hold r.=h. Run/stop of a program Tab. 9 Alarm type éal1 éal2 Value Description éal3 éal4 Off Not used fs.h Active high Absolute fs.l Active low deu.h Active high Deviation deu.l Active low band Out active Band Htr Active high Heater Break lba Loop break alarm (Al1 only) 18
20 4 - Operation AL1, AL2, AL3, AL4 ALARMS CONFIGURATION It is possible to configure up to 4 alarms: AL1, AL2, AL3, AL4 (see pag. 17), selecting, for each of them: A the type and the operating condition of the alarm (table 9 page 18) B the functionality of the alarm acknowledgement (latching) àltch C the start-up disabling (blocking) àbloc D the physical output of the alarm àopi àop2 àop3 The outputs can be used for alarms if they are not used as control outputs (see par page12) It is possible to route up to 4 alarm to a single output (OR of the alarms). Alarm occurrence display This function can be enabled by the configuration software. (please read the user instruction on the "M5 LINE MODBUS /JBUS PRO- TOCOL", supplied separately) The type of alarm is presented flashing, on the front panel in alternation with the PV value f.5.H The red led of the activated alarm output is on. The range of the alarm threshold correspond to the whole span and it is not limited by the SP span. [A] OPERATING CONDITIONS Absolute alarm On Off active low é-fsl hyd hyu On Off active high é-fsh low range high range Alarm threshold Deviation alarm On SP active low é-del - range Off Band alarm active out é-bnd full scale hyd SP hyu Alarm threshold hyd hyu SP active high é-deh On Off hyd hyu + range On Off SP SP full scale Alarm threshold [B] ALARM ACKNOWLEDGE FUNCTION The alarm, once occurred, is presented on the display until to the time of acknowledge. The acknowledge operation consists in pressing any key. yes ltch After this operation, the alarm leaves the alarm state only when the alarm condition is no longer present. [C] START-UP DISABLING SP SP On Off SP SP On Off Disable Start-up Disable Start-up yes bloc ramp down SP Threshold = SP ± range ramp up [D] LOOP BREAK ALARM LBA When the controller connection to the sensor is discontinued or other faults are detected in the control loop, the AL1 alarm becomes active, after a predefined time of 1 to 9999 s, from the detection of the failure. The alarm state ceases when the fault condition is no longer present. ma C Ilba A / M OP1 ein case of ON-OFF control, the LBA alarm is not active. 19
21 4 - Operation 4.3 PARAMETER SETTING Operator s.p. prog Al mode Menu menu Menu programmer menu (if the option is installed. see page 37) Menu Alarm s menu A The parameter setting procedure has a timeout. If no keys are pressed for, at least, 30 seconds, the controller switches back, automatically, to the operator mode. After having selected the parameter or the code, press $ or % to modify the value (see pag 15 and 31) The value is entered when the next parameter is selected, by pressing the è key. Pressing the í key, the operator mode is presented on the display. é loc é 0 é 0 énone l=r s.p. 1 s.p. 2 s.sel éin:spcala s.p. l éf:spcala s.p. H selection local/remote (local or remote configuration only) loc / rem 1st stored (local only) full scale 2nd stored (local only) full scale Stored selection (local only) none / s.s.p.i / s.s.p.2 low limit from low scale up to sph high limit from splto full scale é Off é Off é 1:00 é 0 sl. u sl. d rtio bias Slope up (user enabled/disabled) Off/1 digit/ [1] Slop down (user enabled/disabled) Off/1 digit/ [1] Ratio (only if local - trim or remote - trim) Remote bias (only if local - trim or remote - trim) -span +span Note [1] The units of the slope parameters are Digit/s, digit/min. digit/hr, according to the choice defined during the configuration. Back to the 1st parameter of the menu. é 0 é 0 é 0 é 0 é 1 é hy.iu hy.id Alarm threshold 1 [2] see table Alarm threshold 2 [2] see table Alarm threshold 3 [2] see table Alarm threshold 4 [2] see table Alarm 1 hysteresis asymmetric upper 0...span/20 in engineering units Alarm 1 hysteresis asymmetric lower 0...span/20 in engineering units 20
22 4 - Operation pid Menu PID menu PARAMETER MENU tune Menu Tuning menu é 1 é 1 é 1 é 1 é 1 é 1 hy.2u hy.2d hy.3u hy.3d hy.4u hy.4d Back to the 1st parameter of the Alarms menu. Alarm 2 hysteresis asymmetric upper 0...span/20 in engineering units Alarm 2 hysteresis asymmetric lower 0...span/20 in engineering units Alarm 3 hysteresis asymmetric upper 0...span/20 in engineering units Alarm 3 hysteresis asymmetric lower 0...span/20 in engineering units Alarm 4 hysteresis asymmetric upper 0...span/20 in engineering units Alarm 4 hysteresis asymmetric lower 0...span/20 in engineering units é 5:0 é 12:0 Proportional band p.b. (PID algorithm only) % of span é 60 t.i. Integral time (user enabled/disabled) (PID algorithm only) Off/ seconds Note [2] A code, specifying the n and the alarm type that has been configured, is displayed. At this point, the user must enter the threshold value, according to the following table. Type and value Mode N and Param. Active high Absolute -fsh Active low -fsl Active high Deviation -deh Active low Band full scale Active out of band Load Threshold 1 100A Active high A AL1 activation delay Active high s -del -bnd -Htr Ilba éoff é 1:00 é 50 é 5:0 é 60 é 12:0 t.d. d.err O.C. Mres p.b. C t.i. C t.d. C Derivative time (user enabled/disabled) (PID algorithm only) Off/ seconds Error dead band 0ff/ digit Overshoot control (user enabled/disabled) (PID algorithm only) Manual reset (user enabled/disabled) (PID algorithm only) Off/1 100% output Proportional band Cool channel (Heat/Cool configuration only) % full scale Cool Integral time (user enabled/disabled) (Heat/Cool configuration only) Off/ seconds Cool Derivative time (user enabled/disabled) (Heat/Cool configuration only) Off/ seconds Back to the 1st parameter of the PID menu é no é no tune Adpt p.b. t.i. t.d. Back to the 1st parameter of the Tuning menu. Initial Tune start (one shot tune) no/yes Continuous Tune start (adaptive tune) (not available with set prgh) no/yes. Calculated Proportional band [3] (display only) (available when adaptive tune is selected) Calculated Integral time [3] (display only) (available when adaptive tune is selected) Calculated derivative time [3] (display only) (available when adaptive tune is selected) Nota [3] These values are not automatically stored on the PID menu parameters P.b.,t.i.,t.d. 21
23 4 - Operation InP Menu Input menu Out Menu Output menu CoMM Menu Serial communication menu Accs Menu Access menu (see page 27) Conf Menu Configuration menu (see page 16) é Off é 0 é 0:1 t.fil In.sh t.sam Back to the 1st parameter of the input menu Filter time constant (user enabled/disabled) Off/ seconds Measure bias Off/ digit Sampling time seconds é 0.5 é 10:.0 é 0.0 é100.0 é Off é Off é 10 OP.Hy t.c. Op. l Op. H Op.r st.op st.tm Output hysteresis (single parameter in case of ON-OFF control algorithm) 0...5% full scale Control Output cycle time (time proportioning only) seconds Control Output low limit (not available in Heat/Cool configuration) % Control output high limit % Control output rate limit (user enabled/disabled) Off/ %/s Control Output soft start value (user enabled/disabled) Off/ % Soft start function activation time (not available if st.op = Off) seconds é 10:.0 é 1 Cool output cycle time tc.c (only with Heat/Cool time proportioning) seconds é 0.5 é9600 Dead band d.bnd (only with Heat/Cool config.) % é100.0 é 0ff é 60 é 0.5 Op.CH Op.rC MU.tM MU.hy Back to the 1st parameter of the Output menu Cool output high limit (user enabled/disabled) (only with Heat/Cool config.) % Cool output rate limit (user enabled/disabled) (only with Heat/Cool config.) Off/ %/ s Motor travel time (only for motorised positioners) seconds Minimum output step (only for motorised positioners) % éjbus Addr baud prot Address Off/1 247 Back to the 1st parameter of the Serial Communication menu Baud rate 1200/ 2400/ / Communication protocol Modb/ jbus 22
24 4 - Operation PARAMETERS The controller parameters have been organised in group, according to their functionality area. SETPOINT MENU #s.p. 1 #s.p. 2 1st stored 2nd stored Values of the two s, that are activated by mean of digital inputs, communication parameters, and keyboard. The active is indicated by the â or ä green led. #s.p. l #s.p. H low limit high limit High and low limit of the SP. The minimum span (sp1-sp2) must be greater than 100 digit. value entered is reached according to the configured rate of change. #rtio Remote Ratio This parameter defines the maximum span of the Remote. #bias. Remote Bias It defines the low range of the Remote, in engineering units. Remote Bias and Ratio Remote signal 10V a b bias = 20 ratio = 0.1 a b bias = 100 ratio = C LR a (b ) b (a ) HR Remote span Range #s.l. u #s.l. d ramp up ramp down This parameter specifies the maximum rate of change of the. Its units are: digit/s, digit/min and digit/hour. When the parameter is Off, this function is disabled and the new value is reached immediately after being entered (through the keyboard, the digital inputs and the serial communication). Otherwise, the PV = Process variable LR = PV low limit HR = PV high limit SR = Remote a (a ) = SR starting point b (b ) = SR ending point 23
25 4 - Operation ALARM MENU (see page 19) If SR starting point is lower then the ending point, both expressed in engineering units: bias= starting point = a b - a rtio= HR - LR Example: bias=20 rtio= (-200) If SR starting point is higher then the ending point, both expressed in engineering units = bias= starting point = a = 0.1 Working (SP) as combination of Local (SL) and remote signal type Loc.t (table 3, page 18) SP = SL + (rtio REM) + bias type rem.t (table 3, page 18) SP = REM + (rtio SL) + bias SIGN = Remote signal percentage SPAN = HR-LR REM = SIGN * SPAN 100 Examples: Local (SL) with an external Trim with multiplying coeff. of 1/10: type = Loc.t rtio=0.1 bias=0 Remote (SR) with an internal Trim with multiplying coeff. of 1/5: type = rem.t rtio=0.2 bias=0 Remote range equal to the Input range: type = Loc.t rtio =1 bias=lr SL =0 PID MENU #p.b. #p.b. C Proportional Band Cool Proportional Band This parameter specifies the proportional band coefficient that multiplies the error (SP - PV) #t.i. #t.i. C Integral Time Cool integral Time It is the integral time value, that specifies the time required by the integral term to generate an output equivalent to the proportional term When Off the integral term is not included in the control algorithm. b - a rtio= HR - LR Example: bias= 100 rtio= (-200) = = àt.d. #t.d. C Derivative Time Cool Derivative Time It is the derivative term coefficient that specifies the time required by the proportional term P to reach the level of D. When Off the derivative term is not included in the control algorithm. 24
26 4 - Operation PARAMETERS (cont.) #O.C. Overshoot control (Automatically disabled when the adaptive tune is running) This parameter specifies the span of action of the overshoot control. Setting lower values (1 >0.01) the overshoot generated by a change is reduced. The overshoot control doesn t affect the effectiveness of the PID algorithm. Setting 1, the overshoot control is disabled. #M.res Manual reset This term specifies the value of the control output when PV = SP, in a PD only algorithm (lack of the Integral term). TUNING Two tuning method are provided: Initial one shoot Autotuning Continuous, self learning Adaptive Tuning When the Autotuning is started, the controller generates a rapid burst of ON - OFF transition and monitors the response, in order to calculate the optimal PID terms parameters. Once calculated the terms values are immediately used in the control algorithm. (a minimun error of 5% of span is needed to start the Autotuning) One shot initial autotuning change PV variable Control output SP End of the tuning operation and start of control with the new terms values Autotune start The self-learning adaptive autotune, is not intrusive. It doesn t affect the process, at all, during the phase of calculation of the optimal terms parameters. It is particularly suitable for controlling process whose control characteristics change with time or are not linear in relation to the values. It doesn t require any operation by the user. It is simple and works fine: it samples continuously the process response to the various perturbations, determining the frequency and the amplitude of the signals. On the basis of this data and their statistical values, stored in the instrument, it modifies automatically the PID term parameters. It is the ideal for all applications where it is required to change continuously the PID terms parameters, in order to adjust the PID to the changes of the process dynamic conditions. Continuous adaptive tune Perturbation New parameters In case of power off with the Adaptive Tune enabled, the values of the PID terms parameters are stored, in order to be reused at the next power on. At power on the Adaptive Tune starts automatically. INPUT MENU #t.fil Input filter Time constant, in seconds, of the RC input filter on the PV input. When this parameter is Off the filter is bypassed. Filter reponse 100% 63,2% 0 Filter Time #In.sh Measure Bias This value is added to the measured PV input value. Its effect is to shift the whole PV scale of its value (±60 digits). #t.sam. PV Time Sampling Time Sampling time, in seconds, of the instrument. This parameter is normally used when controlling slow process, increasing the sampling time from 0.1 to 10 seconds. 25
27 4 - Operation OUTPUT MENU #Op.hy Off Control output hysteresis Control output hysteresis span, hy, set in % of the full scale. #t.c. #t.c. C Control output cycle time Cool cycle time It s the cycle time of the time propotioning control output. The PID control output is provided by the pulse width modulation of the waveform. #Op. l Control Output low limit It specifies the minimum value of the control output signal. It is applied in manual mode, too. #Op. H #Op.C.H SP hy Control output high limit Cool output high limit On It specifies the maximum value the control output can be set. It is applied in manual mode, too. #Op.r #Op.rC Heat output maximum rate Cool output maximum rate This value, specified in %/seconds, with range from 0.01 to 99.99%/s provides the maximum rate of change of the output. When set to Off this function is disabled. #st.op Soft start of the control output It specifies the value at which the control output is set during the start up phase. #st.tm Soft start time This value specifies the time the start up phase lasts. The start up phase starts at power up of the controller. OP 100% àst.op Soft start phase Start up àop.r Speed in %/sec. Time #d.bnd Heat/Cool deadband This parameter specifies the width of the deadband between the Cool and the Heat channel Heat / Cool algorithm Heat 100% àop.h. Heat P.b. 100% % Heat output Cool output #MU.tM Travel time It provides the time required to the motor positioner to go from the 0% position to 100% #MU.hy SP d.bnd Cool P.b. / C Minimum step àopc.h It specifies the minimum allowed time of activation of the output to a motor positioner that produces a sensible effect. It is related to the deadband of the positioner SERIAL COMMUNICATION MENU #Addr Controller address The address range is from 1 to 247 and must be unique for each controller on the communication bus to the supervisor. When set to Off the controller is not communicating #baud Baud rate It provides the baud rate in the range from 1200 to bit/s. #Prot Communication protocol Modb/ jbus This Slave protocol allows the supervisor to read and write (when it is possible) all the parameters of the controller. ACCESS MENU (see page 27) CONFIGURATION MENU (see page 16) 26
28 4 - Operation 4.4 ACCESS LEVEL - PASSWORD - CALIBRATION Accs Operator mode Menu Access menu Press until NO II A.pas OK Enter password for access enable from -999 to 9999 (11 default value from factory) If the password entered corresponds to the one stored in the A.pas [A] parameter, the access configuration page is displayed. YES Note Pressing í go back to the Operator mode [1] With the level of access set to full, all the related parameters are displayed. full Ac.le none EHec Access to all the levels [1] Execute the following operations Oper Ac.le C.pas EHec Operator level Access Change the Configuration password Edit Ac.le A.pas EHec Access to the edit level Change the Access password yes E.AMn A/M enable / no 33 C.pas Enter the Configuration password II A.pas Enter [A] the Access password 27
29 4 - Operation 4.4 ACCESS LEVELS PASSWORD CALIBRATION With the access level Edit, the user defines which groups and parameters are accessible to the operator After selecting and confirming the access level Edit, enter in the parameters menu. The code of the access level is displayed on the front panel. Press the $ and % keys to select the proper level. Group of parameters Code Access level pid Menu read Hide Visible Not visible Parameters Code Access level 35.0 p.b. AItr fast read Hide Visible and changeable Included in Fast view Visible only Not visible and not changeable The parameters in the access level fast are recalled on the front panel through the procedure of fast parameter access illustrated in par. 5.2 pag 29. The maximum number of fast parameters is 10. At the end of the parameter list of the selected group, the controller quits from the Edit access level. Therefore, the Edit level must be selected for each group of parameters C.pot EHec Calibrate the potentiometer (if present) The access level of groups and parameters, is activated through Oper Ac.le Access level operator load EHec Load the data from Memory chip Confirm and return back to the Operator mode stor EHec Download the data to Memory chip potl O 255 poth The valve go to low scale When the indication (the valve) is stopped, confirm the calibration value using $ or % The valve go to full scale Confirm 28
30 5 - Displays 5 DISPLAYS 5.1 STANDARD DISPLAY 5.2 FAST VIEW (fast access to the parameters) Manual mode Operator MAN mode C Automatic mode Engineering units With this procedure, simple and fast, up to 10 parameters, selected through the fast view (see par 4.4 page 28) are displayed and can be modified by the operator without requiring the standard parameter setting procedure. Press $% in order to modify the parameters The value is entered by pressing è key SW release and first part of instrument code (HW) 00A rel. A B C D 3150 Hard Software release Base product code (see page 5) 63.0 Op t.s.p. 50 t.cur OP1 output value (not displayed if ON-Off) Target value local mode only (not displayed if the Slopes are disabled) Load current in Ampere (CT option only) Example of common parameters included in the fast view (fast access) no tune fs.H none s.sel One shot tune start no/yes Alarm 3 threshold (high absolute alarm) full scale Stored selection none/s.s.p.i/s.s.p.2 Back to the Operator mode Back to the operator mode 29
31 6 - Commands 6 COMMANDS COMMANDS TO THE CONTROLLER AND OPERATING PHASES The commands can be entered in 3 ways: REM SP 1 SP 2 A / M RUN MAN KEYBOARD modification (page 31) local/remote selection (page 31) stored display (page 31) manual mode (page 32) tuning start (page 32) programmer stop (page 38) 6.2 DIGITAL INPUTS see page SERIAL COMMUNICATIONS see the manual on this topic 30
32 6 - Commands 6.1 KEYBOARD COMMANDS A. SETPOINT MODIFICATION The is directly modified with the $% keys. Once entered, the new value is checked and becomes operating after 2 seconds. The end of this phase is flagged by flashing momentarily the display with SP after 2 seconds Operator mode Example of modification from 275 to 350 Modified value Flash momentarily the SP value to confirm that it has become operating. back to the operator mode B. LOCAL/REMOTE C. STORED SETPOINTS SELECTION Operator s.p Menu Local/remote selection Select remote Select local mode loc l=r rem l=r loc l=r menu Press until The selected becomes operating pressing the è key. when in remote, the green led is on Ü The is directly modified with the $% keys. Once entered, the new value is checked and becomes operating after 2 seconds. This phase is flagged by flashing momentarily the display with SP. Stored display 1st stored 2nd stored none s.sel s.s.p.1 s.sel s.s.p.2 s.sel The selected becomes operating pressing the è key. The two âä leds flag the operating. Back to the operator mode Back to the operator mode Note: When the value is changed, the entered value is reached with a maximum rate set by the ramp up àsl.u and ramp down, àsl. d parameter. This applies to all the models and in all the operating modes. It is suggested to set àsl. u and àsl. d to Offwhen the remote is operating. The entered is defined as target. It is displayed in the function menu at the parameter t.=s.p. If the slope parameter is set to zero the variation occurs instantaneously. Example change Initial = 250 C t Target = 350 C àsi. u = 10 digit/minutes t = 10 minutes 31
33 6 - Commands AUTO/MANUAL MODE MAN MAN MAN 35.0 Operator mode (automatic) Select manual green { led on Modify the output value TUNING This controller is provided with 2 different Tuning algorithm tune Menu press until One shot tune no tune One shot tune for calculating the optimal PID terms parameters. press until Continuous tuning (adaptive tune) for a continuous calculation of the PID terms parameters in order to adapt the control to dynamically changing process or not linear ones. Continuous tune (adaptive tune) no Adpt (Not present with programmed ) Back to the operator mode AUTO 100% SP SP (PV) MAN PV AUTO SP Op.r Confirm yes to start Confirm no to stop yes tune no tune The command start/stop is executed pressing the è key. When the controller is calculating the PID terms parameters, the led is flashing { Confirm yes to start Confirm no to stop yes tune no tune The command start/stop is executed pressing the è key %output OP OPMAN=OPAUTO change OP OP co OP 0 ST SP = PV Y OPAUTO=OPMAN After the execution of the tuning, the calculated values are automatically presented in the PID menu. When this function is in progress, the calculated values are visible in the Tuning menu but cannot be modified. (see page 21) 32
34 6 - Commands 6.2 DIGITAL INPUT COMMANDS A function is assigned, through the configuration procedure to each IL1 and IL2 digital input. (see the parameters setting at tab 8 at pag 17). The configured function is activated when the digital input (free voltage contact or open collector output) is in the On state. It is deactivated by setting the input to the Off state. The activation of the function through the digital input has the highest priority than through the keyboard or through the serial communication. Function Parameter value Performed operation Note None ànone Not used Set manual mode àa.man Automatic Manual Keypad lock àkeb.i Unlock Locked PV measure hold slopes inhibition àh.pu àslo.1 Off Normal operation Rate limiting is active On PV is hold Normal operation With the keypad locked the commands from digital inputs and serial communication are still operating The value of PV is frozen at the time the digital input goes to the close state When the input is in the on state, the is changed in steps Standard 1st stored 2nd stored Remote àsp.1 Local 1st SP àsp.2 Local 2nd SP àl=r. Local Remote If more than one digital input is selecting a, the last to be activated is the one operating. Programmed Start/stop of a program àh.=r. Hold/Run The status (RUN/HOLD) changes every time the digital input switches from Off to On. 33
35 7 - Programmed 7 PROGRAMMED SETPOINT INTRODUCTION The controller supplied with the programmer option (mod. M5-3 &) offers, in alternative to the adaptive tuning, the functionality to define, store, display and execute a program consisting in the profile in time. MAIN CHARACTERISTICS 1 program, 16 segments/program start, stop, hold etc, commands from the keyboard time base in seconds, minutes or hours continuous or up to time cycling of the program 1 OP3 digital output with the state profile defined by the program setting of the maximum allowed deviation from the 7.1 PROGRAM STRUCTURE The program consists of a sequence of segments. For each segment, it is specified: the to reach às.p. the duration of the segment àt.i. the state of the OP3 output The program consists of: 1 initial segment named O 1 end segment named f 1 14 normal segments always present àsp== Normal segments These segments build up the profile program. There are 3 types of segments: Ramp Dwell àti.== àsp.== àti== àti.== àsp.== Initial segment Its main purpose is to define the value the process variable has to maintain before starting the program. End segment Its main purpose is to define the value the process variable has to maintain at the end of the program and until further changes of. Step àsp.== àti.== = 0 s.p. = Target setpoint ti. = Duration = Previous segment = Current segment = Next segment 34
36 7 - Programmed EXAMPLE OF SETPOINT PROFILE C Program start àsp. I àsp. 2 àsp. 3 àsp. 4 Maximum allowed deviation band àsp. 9 àsp.10 àsp.11 àsp.12 àsp.13 àsp àsp. 0 àsp. f time Segment Initial / End Time t0 t1 t2 t3 t4 t5 t9 t10 t11/t12 t13 t14 The OP3 digital output state, during the segments, is defined in the program OP3 Digital Output àcio àopn àcio contact close (On) àopn contact open (Off) 35
37 7 - Programmed 7.2 SETPOINT PROGRAMMER OPERATION MAXIMUM ALLOWED DEVIATION ( band ) If the PV controlled input value exceeds the band, centred around the SP, the segment time is extended of the same time the PV input stays out of the band. The band width is defined in a parameter of the program segment. The actual segment period is calculated as ti..== +Ti A. Ramp àband RE-START OF A PROGRAM AFTER A POWER FAILURE The parameter #fail. specifies the behaviour of the programmer at power up (see pag.37). Selected between the following 3 choices: #Cont Continue #res Reset #ramp Ramp If #Cont is selected, the execution of the program starts from the point reached at the power failure time. All the parameters, like and the remaining time are restored at the values they had at power off. SP Power Off The drawing below illustrates the situation. Power off during a dwell Power Off SP PV Ti àti.-- àti.-- + Ti àband PV ti Power Off time If #res is selected, at power on the program ends and goes back to local mode. Power off during a ramp Power Off B. Dwell SP PV Ti àti.-- ti.-- + Ti àband àband If #ramp is selected, the execution of the program starts from the point reached at the power failure time. In this case, the programs continue with PV reaching SV with a ramp, whose slope corresponds to the one of the segment running at the power off. ti 36
38 7 - Programmed 7.3 CREATION AND MODIFICATION OF A PROG Operator mode prog Menu Program menu (if present) PARAMETER MENU stat Program status res = reset Hold= hold run = start ti. O Segment 0 time Unit sp. f End segment whole range [1] One digital output is provided which can be controlled by the program. This output is OP3. If this functionality is not required, it can be inhibited by setting Off the parameter àd.o.-- fail Unit n.seg Cyc. band Restart after a power off Cont= continue res = reset ramp= continue with the slope Time units p.sec = seconds p.min = minutes p.hr = hours N of segments 1 14 max N of program cycles Off / Allowed deviation Off / 0 span/20 sp. 0 do. O ti. I sp. 1 do. I Segment 0 whole range Segment 0 Digital output [1] Clo = closed Opn = open Off = inhibited Segment 1 time Unit Segment 1 Intera scala Segment 1 Digital output [1] do. f Back to the 1st parameter Continue for all the 14 normal segments End segment digital output[1] Clo = closed Opn = open Off = inhibited 37
39 7 - Programmed 7.4 START/STOP OF A PROGRAM DIRECT MODE WITH THROUGH THE PARAMETER MENU The various commands, supported by the controller, are different for each of the following operating phases: A] when in Local mode B]during the execution of a program C]when the program is in hold Operator mode (local ) PARAMETER MENU prog Menu Program menu Commands supported by the controllers Press until Type of operating setpoint Phase Supported commands The different phase are displayed in a chained way, just for easing the understanding of the functionality. Two different mode for starting and stopping a program are provided: direct mode with the ê key through the parameter menu 38 Local Programmed Programmed Start of a program A Setting of Local setpoint Program start Program stop in local mode Execution of a program B Program hold Program stop in local mode Hold of a program C Program continuation Program stop in local mode When the program is ended it comes back to normal mode Program start RUN Program Hold RUN Continue up to the program end Program running Ö led continuously on Program hold Ö led flashing run stat Hold stat res stat Program start Program hold Program reset A The Ö green led is flashed at high rate when the controlled variable is out of the allowed deviation band The current time of a segment is hold up to the time the variable re-enter in the band.
40 8 TECHNICAL SPECIFICATIONS Features at 25 C env. temp. Total configurability Operating modes Control mode PV input (see table 1 page 18 for the signal ranges) Description The choices are: input type, operating mode, type of control, safety strategies, alarm strategies 1 loop with single/double output 1 loop as the latter with the addition of the programmer Algorithm PID with overshoot control or On-off PID with velocity algorithm, for controlling motorised positioners Proportional band (P) % Integral time (I) s Derivative time (D) s (user enabled/disabled) Error band digit Manual reset 1 100% output (user enabled/disabled) Cycle time s Hysteresis % Dead band Cool proportional band Cool Integral time Cool Derivative time Cool cycle time Motor travel time Motor minimum step Feedback potentiometer Common characteristics Accuracy 0.25% ± 1 digits for temperature sensors 0.1% ± 1 digits (for mv and ma) PID control 8 - Technical Specifications Time proportioning control Discontinuous control ON-Off control % % s Heat/Cool control (user enabled/disabled) s s s % Motorised positioner 100Ω 10KΩ A/D converter with resolution of points Update measurement time: 50 ms Sampling time (max update time of the output) : s configurable Input bias: digit Input filter with enable/disable s Between V~ the error is minimal 39
41 8 - Technical Specifications Features at 25 C env. temp. Description Resistance thermometer (for T: R1+ R2 must be <320Ω) Pt100Ω a 0 C (IEC 751) C/ F selectable 2 or 3 wires or 2 Pt100 for T Max. wire res.: 20Ω (3 wires) Input drift 0.1 C/10 C Env. temperature <0.1 C/10Ω Wire Resistance PV input Auxiliary inputs (options) Digital inputs Control output (cont.) Thermocouple DC input (current) DC input (voltage) Remote Not isolated accuracy 0.1% CT current transformer Potentiometer 2 logic L,J,T,K,R,S (IEC 548) C/ F selectable 0/4 20mA Rj = 30Ω 0 50 mv Rj = 10MΩ 1-5/0-5/0-10V Rj = 10KΩ Current 0/4 20mA Rj = 30Ω Voltage 1-5/ 0-5/ 0-10V Rj = 300KΩ max span 50 or 100 ma hdw selectable 100Ω 10KΩ supply 300mV The closure of the external contact produces any of the following actions: Internal cold junction compensation Single or double channel, direct or reverse action Minimum limit % (OP1 heat) Maximum limit % (OP1 heat), % (OP2 cool) Engineering units Configurable decimal point position with or without Initial scale.: Full scale.: (minimum range of 100 digits) Bias in engineering units and ± range Ratio from Local + Remote Max. wire res.: 150Ω Input drift <2µV/ C Env. temperature <5µV/10Ω Wire Resistance Input drift <0.1% / 20 C Env. Temp. <5µV / 10Ω Wire Res. Display from 10 to 200 A resolution of 1A with alarm threshold (Heater break alarm) Position feedback measurement Auto/Man mode change, Local/Remote mode change, Stored s activation, keypad lock, measure hold and slopes inhibit. Start, stop, hold of a program (only with programmer) 40
42 Features at 25 C env. temp. Control output Alarms OP4 analogue output (optional) Description Maximum slope Safety value Time proportioning Analogue Motor positioner (3 states) Raise - Stop - Lower SPST NO, 2A/250V~ resistive load Hysteresis % symmetrical Actions Galvanic insulated: 500 V~/1min. Resolution: 12 bit (0.025%) Accuracy: 0.1%. Short circuit protected %/s up and down %. (user enabled/disabled) Relays NO 2A/250V~ resistive loads Triac 1A/250V~ resistive loads 0 22V, 20mA max SSR drive (for static switches) Current 0/4 20mA max 750Ω/10V max 0 1/5/10V Voltage 500Ω / 20mA max Double action 2 poles NO, 2A/250V~ resistive load Active high Active low Special functions Ramp up and down, with slope in digit/s, digit/minute or digit/hour between % of the range High and low limits Action type Deviation threshold Band width Absolute threshold Heater Break detection Loop Break Alarm Activation inhibit (blocking) Acknowledge (latching) Related to the program (optional) (OP3) Current 0/4 20mA 750Ω/10V max Voltage 1-5/0-5/0-10V 500Ω/20mA max Local plus 2 stored s Only Remote Local and Remote Local with trim Remote with trim Time programmable (optional) 8 - Technical Specifications Galvanic insulation 500V~/1min. Resol.: 12 bit (0.025%) Accur. 0.1%. Short circuit protection ± range 0 range Whole scale Retransmission of PV or SP 41
43 8 - Technical Specifications Features at 25 C env. temp. Programmable (optional) Description 1 program, 16 segments (1 initial and 1 end) From 1 to 9999 cycles or continuous cycling (Off) Time values in seconds, minutes and hours Start, stop, hold, etc. activated from the keyboard, digital input and serial communications. Tuning Auto/Manual station Serial com. (optional) Auxil. supply One shot Tune- step response method for calculating the PID terms parameters Adaptive Tune self-learning, not intrusive, analysis of the process response to perturbations and continuously calculation of the PID parameters (not available with the Programmer option) Integrated in the controller, bumpless Operated from keyboard, digital input and serial communication. RS485 isolated, Modbus-Jbus, 1200, 2400, 4800, 9600, bit/s, 2 wires 18V ± 20%, 30mA max for transmitters (2, 3, 4 wires) Measure input Control output Detection of out of range, short circuit or sensor break with automatic activation of the safety strategies and alerts on display Safety value: %. (user enabled/disabled) Operational safety Parameters Parameters and configuration data are stored in a non volatile memory for an unlimited time. They are organised in functionally homogeneous groups, like: visible and changeable, visible and not changeable, not visible. Access protection Password to access the configuration data and the parameter protection menu General characteristics Supply Electric safety Electromagnetic compatibility UL and cul Omologation Protection EN Dimensions V~ (- 15% + 10%) 50/60Hz or 24V~ (- 25% + 12%) 50/60Hz and 24V (- 15% + 25%) power consumption 3W max Compliance to EN61010, installation class 2 (2500V) pollution class 2 Compliance to the CE standards for industrial system and equipment File E IP20 termination unit, IP65 front panel 1 / 16 DIN - 48 x 48, depth 150 mm, weight 230 g approx. 42
44 Warranty G.&P. Grafica & Pubblicità Gazzaniga (BG) G & P@ m a i l- g a t e. n e t 1 WARRANTY We warrant that the products will be free from defects in material and workmanship for 3 years from the date of delivery. The warranty above shall not apply for any failure caused by the use of the product not in line with the instructions reported on this manual. 43
45 ASCON S WORLDWIDE SALES NETWORK SUBSIDIARY FRANCE ASCON FRANCE Phone Fax AGENCE SUD-EST Phone Fax AGENCE RÉGION-EST Phone Fax DISTRIBUTORS ARGENTINA MEDITECNA S.R.L. Phone Fax AUSTRALIA IPA INDUSTRIAL PYROMETER (AUST) PTY.LTD Phone Fax FINLAND & ESTONIA TIM-TOOL OY Phone Fax GERMANY MESA INDUSTRIE ELEKTRONIK GMBH Phone Fax GREECE CONTROL SYSTEM Phone Fax BRANCH OFFICE Phone Fax HOLLAND TEMPCONTROL I.EP. B.V. Phone Fax PORTUGAL REGIQUIPAMENTOS LDA Phone Fax SPAIN INTERBIL S.L. Phone Fax BRANCH OFFICES Phone Fax Phone Fax SWITZERLAND CONTROLTHERM GMBH Phone Fax TURKEY KONTROL SISTEMLERI LTD Phone Fax UNITED KINGDOM EUKERO CONTROLS LTD Phone Fax
Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line
BT. 2.9 M/E Process controller programmer /6 DIN - 48 x 48 mm gammadue series M line Advanced features, customizable and process adaptable High speed data aquisition and signal management. Efficent information
X3 line. Double action controller with analogue output 1 / 8 DIN - 48 x 96 ISO 9001. ASCON spa. Certified. ASCON spa
Double action controller with analogue output 1 / 8 DIN - 48 x 96 ASCON spa ISO 9001 Certified X3 line User Manual M.I.U.X3-4/04.02 c Cod. J30-478-1AX3 IE C UL LISTED US ASCON spa 20021 Bollate (Milan)
J1 line M.I.U.J1-1/05.02 Cod. J30-478-1AJ1 IE
Two alarms indicator 1 / 8 DIN - 96 x 48 ASCON spa ISO 9001 Certified J1 line User Manual M.I.U.J1-1/05.02 Cod. J30-478-1AJ1 IE C c UL LISTED US ASCON spa via Falzarego, 9/11 20021 Bollate (Milano) Italy
M3 line User manual M.I.U. M3-5/04.06 Cod. J30-478-1AM3 IE
Temperature Controller 1 / 16 DIN - 48 x 48 ASCON spa ISO 9001 Certified M line c User manual M.I.U. M -5/04.06 Cod. J0-478-1AM IE C UL US LISTED ASCON spa via Falzarego, 9/11 20021 Bollate (Milan) Italy
Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C
F4 Process Controller Installation and Operation Guide SAFETY ALERTS The symbols below are used on the equipment and throughout this document to draw the user s attention to important operational and safety
Process controller with PROFIBUS DP and Modbus Master/Slave 1/8 DIN - 48 x 96 mm gammadue series X5 line
BT. 2.22 X/E Process controller with PROFIBUS DP and Modbus Master/Slave /8 DIN - 48 x 96 mm gammadue series X line Sophisticated multifunction process controller with high level communications By its
Process controller with PROFIBUS DP and Modbus Master/Slave 1/4 DIN - 96 x 96 mm gammadue series Q5 line
BT. 2.3 Q/E Process controller with PROFIBUS DP and Modbus Master/Slave / DIN - 96 x 96 mm gammadue series Q line Sophisticated multifunction process controller with high level communications By its three
Heat-Cool temperature controller 1/8 DIN - 48 x 96 mm gammadue series X1 line
BT.. X/E Heat-Cool temperature controller /8 IN - 8 x 96 mm gammadue series X line Cost effective solutions Ideal for Heat/Cool control, with the capability to check the load current by current transformer.
HONEYWELL DC 1010 / 1020 1030 / 1040 DIGITAL CONTROLLER PRODUCT MANUAL 51-52-25-113 06/02
HONEYWELL DC 1010 / 1020 1030 / 1040 DIGITAL CONTROLLER PRODUCT MANUAL 51-52-25-113 06/02 Before using this manual, please check to ensure the Model number, input type Range and output match your requirements.
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.
TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection
Auto-tune PID. Temperature Controller BRAINCHILD FEATURES
Auto-tune PID Temperature Controller FEATURES Easy-to-use Fuzzy modified PID heat & cool control Fast A-D sampling rate (5 times/s) Universal input (PT100, thermocouple) with high accuracy 18-bit A-D Analog
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.
THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012
Technical Information THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012 GENERAL DESCRIPTION THYRISTORS T1-1PH is a full digital and universal
Panel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
PID Microprocessor temperature controllers CTD43 - CTD46 - CTH46
PID Microprocessor temperature controllers CTD43 - CTD46 - CTH46 Display 1. Red measurement display (or the set point for CTD 43 by pressing, indicated by a flashing decimal point). 2. Green display of
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:
COMMUNICATION INSTRUCTION MANUAL TEMPERATURE CONTROLLER KT4, KT8 and KT9 No.KTC1E6 2009.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.
+ A + + - B V B - - + + + NO NC V COM - - - PV PV
+ - A + B B - V + - NO NC COM + - + - V + - PV PV Ramp Soak 100 70 50 30 3 5 3 8 5 3 Minute Steam Heating Sensor Cooling Water PID Hotplate Specifications Input power supply AC 100 to 240V, 50/60Hz, DC
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)
Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual
Ⅰ. Warn Warning of connection Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual If the controller fails to operate or error occurs, the system will bring fault for it, please
HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply
1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
ZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
T-100-R Installation Guide
T-100-R Installation Guide Table of Contents Page 2 Overview T-100-R Z-Wave Thermostat 3-4 Installation HVAC System Setup 6 Installer Settings Menu Items 7-9 Installer Settings Summary 10-11 Wiring Standard
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
Dyeing Programmer DP - 01
Dyeing Programmer DP - 01 Display and Controls. 1) Display: 16/2 alphanumeric display 2) Temperature range: 0 to 150 degree. 3) Resolution: 1 degree. 4) Accuracy: +/- 1 degree. 5) Temperature control setting:
TC 1818a. Operating Guide. Control Module SWM-015.5
TC 1818a Control Module Operating Guide SWM-015.5 This guide is intended solely for use by owners of Thermon HeatChek TM heat tracing control and monitoring units. This manual describes operation for TC
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
SYL-2372 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Version 1.4 (May 2016)
AUBER INSTRUMENTS Instruction Manual SYL-7 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Version 1.4 (May 16) Caution This controller is intended to control equipment under normal operating conditions.
HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function
Specifications Supply Voltage 240VAC @ 0.07Amps or 24VAC @ 0.380Amps Relays 240V @ 12A max (resistive) / Comp1,2,3, Aux Ht, Rv O/B) Fuses (Equipment) 15 Amps Maximum 3AG Control Range Minus 10 to 50C Control
NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module
NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module 1. General Description 1 2. General Warnings 1 3. Interface 2 4. Temp Alarms Setting 3 5. Programming 3 6. Light Management 4 7. Installation and
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
LDG DTS-4/4R Desktop Coaxial Switch / Remote
LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 [email protected] www.ldgelectronics.com
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
User Manual Auto Tuning PID Temperature Controller
User Manual Auto Tuning PID Temperature Controller TUPC-T series (Applicable for accurate controls of Temperature) TEMPSEN DEVICES Plot No : 2&3, Balaji Nagar, 4 th Street, Mettukuppam, Thoraipakkam, Chennai-600097
Inwall Room Temperature Unit
Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall
A1000 Cheat Sheet (Open Loop Vector)
A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to
Multifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
Short Form Catalogue. Alarm Systems. Reliable Supervision and Control
Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Controller Automation, Model II+
Controller Automation Page 2 of 2 Automation with the RADAK II+ power controller II+ I/O Points: Inputs 5 Programmable Digital inputs 2 Dedicated digital inputs (Channel select and External SCR control
TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES
SED-635 Digital Excitation System SED-635 is a complete excitation system capable of adapting to control synchronous generators of any size. The integration of the TOUCH SCREEN operator interface and a
Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits
Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Product overview The Tracer ZN517 controller is a field-installed, application-specific controller that provides directdigital
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.
T0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
T7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM
TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution
Preliminary. Dual-line FLOW rate/totalizers. Pr ovu Model PD6200 Analog Input. Pr ovu Model PD6300 Pulse Input. Analog Inputs.
Dual-line FLOW rate/totalizers Pr ovu PD6200 Analog Input ProVu Se r i e s Pr ovu PD6300 Pulse Input Analog Inputs 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, and ±10 V Inputs Isolated 24 VDC @ 200 ma Transmitter
Bulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) 876-4444 Tel: (203) 426-7700 Fax: (203) 426-7800 www.walkeremd.
Eclipse Series Digital Panel Meters Installation and Operation Manual Number 57700-900-05 Models: 5770X-40X - DC Volts 5770X-4X - AC Volts 5770X-42X - DC Amps 5770X-43X - AC Amps 5770X-44X - 5A AC 5770X-45X
REGTRONIC OPERATING INSTRUCTIONS
REGTRONIC OPERATING INSTRUCTIONS 1.FEATURES Electrical connection: M12 8-pin connector Preset pressure range 0.05-10 bar with possible full scale regulation. 10 100 mbar adjustable deadband Supply pressure:
DC1000 Series General Purpose UNIVERSAL DIGITAL CONTROLLERS
DC1000 Series General Purpose UNIVESA DIGITA CONTOES PODUCT SPECIFICATION SHEET OVEVIEW The DC1000 family of microprocessor based controllers combine a high degree of functionality, reliability at a very
Meter Relays. 077 Series Analogue Meter Relays. Features. Applications
077 Series Analogue Features Monitors and controls any variable which can be converted to an A.C. or D.C. signal. Rugged, shock and vibration resistant design Indicator, relays and power unit in one housing
Conventional Fire Detection and Extinguishant Control System Specification
Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new
WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
Option field bus: without bus with profibus DP. Design-Index (Subject to change)
Amplifier / controller cards ED1 Digital amplifier / controller card ED1 for 1 or 2 proportional solenoids 4 analogue inputs, of which 2 for differential inputs 8 digital inputs Card setting via PC, multi-function
Programmer/Controller
Systems Plus START 7 8 9 envirotronics ALARM STOP 4 5 6 ALARM ACK Instrument Manual Systems Plus Programmer/Controller OFF HELP 1 2 0 3. ENTER ALARM RESET DEL Revision 6 9/12/97 Table of Contents 2 Menu
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power
Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
Thyristor power units and Solid state contactors. TC2000 series. Two-phase control of a three-phase load or control of two single-phase loads
Thyristor power units and Solid state contactors TC2000 series Two-phase control of a three-phase load or control of two single-phase loads User Manual Copyright Eurotherm Automation 1995 All rights reserved.
How to read this guide
How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation.
PRELIMINARY TECHNICAL INFORMATION Three-phase Digital SCR Firing Board HIGHLIGHTS - Up to 480 V AC input supply voltage - Up to 700 V AC sync input - DSP controlled - Digital or analog input signaling
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)
000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,
Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)
February 2015 February 2015 Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC) This document describes how to connect an electricity meter to a SolarEdge device (inverters,
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
WIRELESS MAGNETIC CONTACT
WIRELESS MAGNETIC CONTACT The magnetic contact wireless MAG HCS is a sensor able to detect opening or closing doors or windows and transmits via radio a alarm signal. It is composed of two distinct elements:
Process Alarm Solutions
Process Alarm Solutions Reliable Supervision and Control www.selco.com SELCO flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring of electrical
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way
1115 4G SERIES GOVERNOR. 4-20 ma ANALOGUE DIGITAL SPEED SETTING
1115 4G SERIES GOVERNOR with 4-20 ma ANALOGUE & DIGITAL SPEED SETTING PO Box 28, 9300AA Roden, The Netherlands Tel: +31 505019888 Fax: +31 505013618 E-mail: [email protected] 1115 4G
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
650W Single Output Power Supply
AK-650 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( % ~ 05% ) High efficiency up to 9% + / 0.5A auxiliary output Intelligent
NX Series Inverters. HVAC Pocket Programming Guide
NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product
Combi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
Table of Contents. 1 - Specifications...3. 2 - Installation...3. 3 - Wiring...5. 4 - User controls...7
THERMOSTATS Table of Contents Page 1 - Specifications...3 1.1 - Product range...3 ARTTH001 (DSL-610)...3 ARTTH002 (DSL-700)...3 ARTTH003 (DSL-600)...3 1.2 - Technical data...3 1.3 - Power failures...3