1 Two alarms indicator 1 / 8 DIN - 96 x 48 ASCON spa ISO 9001 Certified J1 line User Manual M.I.U.J1-1/05.02 Cod. J AJ1 IE C c UL LISTED US ASCON spa via Falzarego, 9/ Bollate (Milano) Italy Tel Fax [email protected]
2
3 Two alarms indicator 1 / 8 DIN - 96 x 48 J1 line c C UL LISTED US J
4 Information 2 c NOTES ON ELECTRIC SAFETY AND ELECTROMAGNETIC COMPATIBILITY Please, read these instructions carefully before proceeding with the installation of the controller. Class II instrument, rearl panel mounting. This indicator has been designed in compliance with: Regulations on electrical apparatus (appliance, systems and installations) according to the European Community directive 73/23/EEC amended by the European Community directive 93/68/EEC and the Regulations on the essential protection requirements in electrical apparatus EN : 93 + A2:95. Regulations on Electromagnetic Compatibility according to the European Community directive #89/336/EEC, amended by the European Community directive #92/31/EEC, 93/68/EEC, 98/13/EEC and the following regulations: Regulations on RF emissions EN : 2001 residential environments EN : 2001 industrial environments Regulation on RF immunity EN : 2001 industrial equipment and system It is important to understand that it s the responsibility of the installer to ensure compliance with the regulations on safety requirements and EMC. The device has no user serviceable parts and requires special equipment and specialised engineers. Therefore, a repair cannot be carried out directly by the user. For service or repair, contact the manufacturer or your sales represenattive. All the information and warnings about safety and electromagnetic compatibility are marked with the B sign, at the side of the note.
5 Table of contents TABLE OF CONTENTS Main universal input 12 IN J1 Resources OP1 OP2 OP1 Operating mode Alarms OP2 1 INSTALLATION...Page 4 2 ELECTRICAL CONNECTIONS...Page 8 3 PRODUCT CODING...Page 14 4 OPERATIONS...Page 18 5 DISPLAYS...Page 28 6 COMMANDS...Page 29 7 TECHNICAL SPECIFICATIONS...Page 31 Special functions (option) NO/NC Modbus RS485 Parameterisation Supervision (option) 3
6 1- Installation 1 INSTALLATION 1.1 GENERAL DESCRIPTION Installation must only be carried out by qualified personnel. Mounting clamps Before proceeding with the installation of this indicator follow the instructions illustrated in this manual with particular attention to the installation precautions marked with the B symbol, related to the European Community directive on electrical protection and electromagnetic compatibility. B To prevent hands or metal touching parts that may be electrically live, the indicators must be installed in an enclosure. IP 20 Terminal block EN (IEC1010-1) Product code label Panel surface Sealing front panel gasket Front panel IP65 protection EN (IEC 529) 4
7 1- Installation 1.2 DIMENSIONAL DETAILS 1.3 PANEL CUT-OUT 96 mm 3.78 in 10 mm max in max mm in mm in 48 mm 1.89 in 65mm min in min. 10 mm max in max. 113 mm min in min. 110 mm 4.33 in 5
8 1 - Installation 1.4 ENVIRONMENTAL CONDITIONS B Operating conditions M T %Rh Altitude up to 2000 m Temperature 0 50 C Relative humidity 5 95 % non-condensing Special conditions M T Altitude > 2000 m Temperature >50 C %Rh Humidity > 95 % Suggestions Use 24Vac supply version Use forced air ventilation Warm up P Conducting atmosphere Use filter Forbidden Conditions D C E Corrosive atmosphere Explosive atmosphere 6
9 1- Installation 1.5 PANEL MOUNTING [1] INSERT THE INSTRUMENT INSTALLATION SECURING CLAMPS REMOVING INSTRUMENT UNPLUGGING B 1 Prepare panel cut-out 2 Check-front panel gasket position 3 Insert the instrument through the cut-out 1 Fit the mounting clamps as shown 2 Push the mounting clamps towards the panel surface to secure the instrument 1 Insert the screwdriver in the clips of the clamps 2 Rotate the screwdriver 1 Push and 2 Pull forward to remove the instrument UL note [1] For Use on a Flat Surface of a Type 2 and Type 3 raintight Enclosure Electrostatic discharges can damage the instrument Before removing the instrument the operator must discharge 1MΩ himself to ground 2 7
10 2 - Electrical connections 2 ELECTRICAL CONNECTIONS 2.1 TERMINAL BLOCK [1] B RS C 3 N/C 4 N/C 5 13 N/C 14 N/C 15 N/C 16 N/C 17 N/C NC 29 C L N OP1 Rear terminal cover 5.7 mm 0.22 in N/C 6 18 N/C 30 NO N/C 7 N/C 8 N/C 9 A 10 b 11 mv TC B 12 RTD 19 N/C 20 N/C 21 N/C 22 N/C 23 N/C 24 N/C 31 NO OP2 32 C 33 N/C 34 N/C 35 N/C 36 24V OUT ,5 Nm Wire size 1 mm 2 (18 AWG Solid/Stranded) 15 screw terminals M3 Terminals UL note [1] Use 60/70 C copper (Cu) conductor only. Option terminals Tightening torque 0.5 Nm Positive screw-driver PH1 Negative screw-driver 0,8 x 4 mm Ø L Pin connector q 1.4 mm in max. Fork-shape AMP Ø 5.5 mm in Stripped wire L 5.5 mm in 8
11 B PRECAUTIONS Despite the fact that the instrument has been designed to work in a harsh and noisy environment (level IV of the industrial standard IEC 801-4), it is recommended these following suggestions. A All the wiring must comply with the local regulations. The supply wiring should be routed away from the power cables. Avoid using electromagnetic contactors, power Relays and high power motors nearby. Avoid power units nearby, especially if controlled in phase angle mode. Keep the low level sensor input wires away from the power lines and the output wires. If this is not feasible, use shielded cables on the sensor input, with the shield connected to ground. 2 - Electrical connections 2.2 SUGGESTED WIRE ROUTING B A D B 0,5 Nm Conduit for supply and output cables C A Conduit for low level sensor cables D B 0,5 Nm A = Supply B = Outputs C = Analogue inputs D = Serial Communications C 9
12 2 - Electrical connections 2.3 EXAMPLE OF WIRING DIAGRAM B Supervision RS C IN1 PT A 11 b 12 B PTC OP1 OP [3] [6] [5] [5] [6] [5] V ~ Alarm Power supply switch Notes: 1] Make sure that the power supply voltage is the same as indicated on the instrument. 2] Switch on the power supply only after all the electrical connections have been completed. 3] In accordance with safety regulations, install a circuit breaker on the instrument power supply line that is clearly identified with that instrument (or group of instruments). The breaker shall be easily accessible by the operator. 4] The instrument is PTC protected. In case of failure it is suggested to return the instrument to the manufacturer for repair. 5] To protect the instrument internal circuits use: - 2 AT fuse for Relay outputs (220 Vac); - 4 AT fuse for Relay outputs (110 Vac). 6] Relay contacts are already protected with varistors. Only in case of 24 Vac inductive loads, use model A D7 varistors (on request) 10
13 2.3.1 POWER SUPPLY B 2 - Electrical connections MAIN UNIVERSAL INPUT B Switching power supply with multiple isolation and internal PTC Standard version: nominal voltage: Vac ( %) Frequency 50/60Hz Low Voltage version: Nominal voltage: 24Vac ( %) Frequency 50/60Hz or 24Vdc ( %) Included PTC 25 Supply L A L-J-K-S-R-T-B-N-E-W thermocouple type Connect the wires with the polarity as shown; Always use compensation cable of the correct type for the thermocouple used; The shield, if present, must be connected to a proper ground. B For Pt100 resistance thermometer If a 3 wire system is used, always use cables of the same diameter (1mm 2 min.) (line 20 Ω/lead maximum resistance); When using a 2 wires system, always use cables of the same size (1,5mm 2 min.) and put a jumper between terminals 11 and 12. A b B Wire resistance 150Ω max. For 3 wires only. Maximum line resistance: 20Ω/line For better protection against electrical interference, it is recommended not to connect the ground clamp provided for civilian installations. N C For T (2x RTD Pt100) Special A When the distance between the indicator and the sensor is 15 m using a cable of 1.5 mm 2 size produces an error on the measure of 1 C (1 F). R1 + R2 must be <320Ω R1 R2 A B A Use wires of the same length and 1.5 mm 2 size. Maximum line resistance: 20Ω/line 11
14 2 - Electrical connections D For ma, mv OP1 - OP2 B mv ma 11 OP1 SPDT relay output 12 OP2 SPST-NO relay output External shunt 2.5Ω Rj >10MΩ. D1 With 2 wire transmitter Transducer D2 With 3 wire transmitter mA 12 External shunt 2.5Ω Note: [1] Auxiliary power supply for external transmitter 24Vdc ±20% /30mA max. with no short circuit protection 12 ma 4 20mA External shunt 2.5Ω 36 24Vdc [1] Transmitter 24Vdc PV 36 [1] ma OP1 relay output: SPDT relay, 2A/250Vac for resistive load, fuse 2AT at 250Vac, (4A/120Vac, fuse 4AT at 120Vac). OP2 relay output: SPST N.O. relay, 2A/250Vac for resistive load, fuse 2AT at 250Vac, (4A/120Vac, fuse 4AT at 120Vac) ALARM OUTPUTS B OP1 output NC 28 C NO OP2 output [1] Fuse [1] Load Vac [1] Load Fuse Fuse Vac Load Notes: [1] Varistor for inductive load 24Vac only.
15 2 - Electrical connections SERIAL COMMUNICATIONS (OPTION) B C Galvanic isolation 500Vac/1 min. Compliance to the EIA RS485 standard for Modbus/Jbus Setting dip switches O N A Please, read: gammadue and deltadue indicator series serial communication and configuration software technical manual 13
16 3 - Product coding 3 PRODUCT CODING The complete code is shown on the instrument label. Configuration code (software) O P Q R The information about product coding is accessible from the front panel by means of the procedure described in section 5.2 page 28. Basic product code (hardware) I L M N B C D Instrument label P/N : J CONF : S/N : A0A-0450/2210 V~(L-N) : V 50/60 Hz - 4W J
17 3 - Product coding 3.1 MODEL CODE The product code indicates the specific hardware configuration of the instrument that can be modified by authorized personnel only. Model: Configuration Line Basic Accessories 1st part 2nd part J 1 A B C 0-0 F G 0 / I L M N - O P 0 0 Line J 1 Power supply A Vac ( %) 3 24Vac ( %) or 24Vdc ( %) 5 Outputs OP1 - OP2 B None 0 Relay - Relay 7 Serial Communications C None 0 RS485 Modbus/Jbus SLAVE 5 User manual F Italian/English (std) 0 French/English 1 German/English 2 Spanish/English 3 Front panel colour G Dark (std) 0 Beige 1 15
18 3 - Product coding 3.2 CONFIGURATION CODING A 4+4 index code follows the model of the indicator. The code has to be set to configure the indicator (see chapter 3.1 page 15) A If, when the indicator is powered up for the first time, the display shows the following message J1 Conf 1 2 it means that the indicator has not yet been configured. Index 1st part of configuration code E.g. Enter the code 0320 to choose: - T/C type J input with range C; - Change the display color to red when an alarm is active. Index 2nd part of configuration code E.g. Enter the code 2300 to choose: - AL1 absolute, active high; - AL2 absolute, active low. I L M N 0320 O P Q R 2300 Input type and range I L TR Pt100 IEC C F 0 0 TR Pt100 IEC C F 0 1 TC L Fe-Const DIN C F 0 2 TC J Fe-Cu45% Ni IEC C F 0 3 TC T Cu-CuNi C F 0 4 TC K Chromel-Alumel IEC C F 0 5 TC S Pt10%Rh-Pt IEC C F 0 6 TC R Pt13%Rh-Pt IEC C F 0 7 TC B Pt30%Rh Pt6%Rh IEC C F 0 8 TC N Nicrhosil-Nisil IEC C F 0 9 TC E Ni10%Cr-CuNi IEC C F 1 0 TC NI-NiMo18% C F 1 1 TC W3%Re-W25%Re C F 1 2 TC W5%Re-W26%Re C F 1 3 Dc input 0 50mV linear Engineering and units 1 4 Dc input 10 50mV linear Engineering and units 1 5 Custom input and range [1] 1 6 [1] For instance, other thermocouples types, T (with 2 PT 100), custom linearisation etc. The indicator remains in standby until the configuration code is set correctly (pag. 24). 16
19 3 - Product coding Display mode Green M 0 Red 1 Red when alarm 1 (AL1) active 2 Alarm type and function Non-active Sensor break alarm Absolute Deviation Band Rate alarm (AL1 only) Active High Active Low Active High Active Low Active Out Active In O P AL1 AL
20 4 - Operation 4 OPERATIONS KEY FUNCTIONS AND DISPLAY IN OPERATOR MODE J Over range Input value [1] In engineering uits Under range Alarm status LEDs (reds) Å AL1 ON Ç AL2 ON Menu access Alarm acknowledge Min and Max. values display Entry key for selection and value setting confirmation Note: [1] The color of the dislplay is set through field m of the Configuration Code (page 17). 18
21 4 - Operations KEY FUNCTIONS AND DISPLAY IN PROGRAMMING MODE A The parameter setting procedure has a timeout. If no keys are pressed for, at least 30 seconds, the indicator switches back, automatically, to the operator mode. J Parameter Code/Value After having selected the parameter or the code, press $ and % to display or modify the value (see page 20). The value is entered when the next parameter is selected, by pressing the R key. Access to the menu for: Parameter setting Configuration Value modification Back to previous parameter Entry key for selection and value setting confirmation Until the $ or % are pressed or if you wait for 30 seconds, the parameter value is not inserted. Pressing the í key, the next group of parameters is presented on the display. 19
22 4 - Operations 4.2 PARAMETER SETTING NUMERIC ENTRY (i.e. how to the modify a threshold value from to ) Pressing $ or % momentarily changes the value by 1 unit every push. Continued pressing of $ or % changes the value, at a rate that doubles every second. Releasing the button decreases the rate of change. In any case value stops changing the max./min. value has reached limit set for the parameter Operator mode Displays the value of the selected input AL. sp AL.1sp Decrease Access the alarm threshold menu Select the AL 1 threshold Threshold value of AL1 alarm Increase Threshold entry Press the è key to store the new value in the instrument MNEMONIC CODES SETTING (e.g. configuration see page 30) Press the $ or % to display the next or previous mnemonic for the selected parameter. Continued pressing of $ or % will display further mnemonics at a rate of one mnemonic every 0.5 s. The mnemonic displayed at the time the next parameter is selected is the one stored in the parameter. Unit C f C Engineering Units Degree Centigrade Degree Fahrenheit Degree Centigrade f none ph Degree Fahrenheit No unit defined Ph 20
23 4 - Operations 4.3 PARAMETERISATION - MAIN MENU Operator mode pass 5000 Back to the operator mode NO OK YES Direct access to the parameter (only if Code <5000) Password Entry Only if Code value 5000 Must be equal to the value of the parameter Code Back to the operator mode Al. SP Al.par Conf Alarm set [1] (page 21) Alarm parameter setting [1] (pag. 22) Instrument configuration (page 22) Note: [1] The menu apears only if at least one of the alarms has been configured (except for the sensor break alarm) ALARM SET AL sp é 0 AL.1sp é 0.5 AL.1hy é 0 AL.2sp é 0.5 AL.2hy é 0 AL.rEf Back to AL.1SP Alarm threshold menu AL1 alarm threshold AL1 hysteresis AL2 alarm threshold AL2 hysteresis Alarm internal reference value (engineering unit) 21
24 4 - Operations ALARMS PARAMETERISATION MENU AlPar énone AL.1OP Alarms parameterisation menu AL1 alarm output none/opi /Op2/Op3/Op4 Note: [1] Only those alarms that are configured different than zero are shown during the parameterisation phase (fields op page 17) CONFIGURATION MENU When an unconfigured indicator is powered up for the first time, the display shows: Conf See chapters 3, 3.1 and 3.2 starting from page 14. énone é dir é dir 22 AL.2OP OP.1a OP.2a AL2 alarm output none/opi /Op2/Op3/Op4 AL1 alarm action dir/reu AL2 alarm action dir/reu Back to AL.1Sr é 0 AL.1lb é 0 AL.2lb AL1 alarm Latching/Blocking none/ltch /bloc/ltbl AL2 alarm Latching/Blocking[1] none/ltch /bloc/ltbl Conf PASS Back to the operator menu No OK Yes Configuration menu Password Entry Must be equal to the value of the parameter Code énone Con1 Con2 Unit Entering digits I - L - M - N of the configuration code (chapter 3.2 pages 15, 16) Entering digits O - P of the configuration code (chapter 3.2 pages 15, 16) Engineering units (see table 2)
25 4 - Operations é 0 in.1dd é 0 in.1lo é10000 in.1hi é 0 in.1cn é 0 Cut1 LINEAR SCALE ONLY N of decimals 0 3 IN1 Low range = (min. 100 digit) IN1 High range = (min. 100 digit) Square root input IN1 none/ sqrt Cut off IN1 square root value [1] (engineering units) é 0 t.fil1 é 0 in.1sh Filter time constant OFF/1...30s Input shift OFF/ digit éj:bus é9600 é 1 Prot baud Addr Password (password) factory default 33 SERIAL COM. OPTION (if installed) Communications protocol M.buS / jbus Baud rate 1200/ /9600 Serial comms address é 33 Back to the Con.1 parameter Code Table 1 - Engineering units éunit Value Description C Centigrade degrees f Fahrenheit degrees none none mu mv U Volt ma ma A Ampere bar Bar psi PSI rh Rh ph ph Note: [1] Cut off the sqare root of the input value enables the user to round to zero a result that is too low to be meaningful. 23
26 4 - Operations 4.4 PARAMETERS DESCRIPTION For ease of operation of the indicator parameters have been organised in groups (menu), according to their functionality area ALARM THRESHOLD MENU OP1 and OP2 outputs can be used as alarms it is possible to configure up to 2 alarms: AL1 and AL2 (page 22) selecting for each of them: - the type and the operating condition of the alarm (page 26); - the functionality of the alarm acknowledgement (latching) #ltch (page 25); - the blocking function is activated on start up #bloc (page 25); - Sensor break function (page 26); - Rate alarm (AL1 only) (page 26). #Al.1sP #Al.2sP AL1 alarm threshold AL2 alarm threshold Parameters to set the threshold of AL1 and AL2 alarms. The range of the alarm threshold corresponds to the whole span. When the alarm occurs, the display will show the red LEDsÅ and Ç respectively ON and, when configured, with a change of the display colour (AL1 only). #Al.Ihy #Al.2hy AL1 alarm hysteresis AL1 alarm hysteresis Hysteresis of the threshold of AL1 and AL2 alarms. It is specified as a % of the full scale. 24
27 4 - Operations ALARM PARAMETERS CONFIGURATION MENU AL1 alarm #AL.1Op output AL2 alarm #AL.2Op output These parameters connect each alarm to the output port to be activated when an alarm condition occurs. Values: none, OP1, OP2. Default values: AL1: OP1 AL2: OP2. Output OP1 #Op.1a action Output OP2 #Op.2a action These parameters set the type of action of the output port. Values: direct (relay-coil excited when in alarm condition), reverse (relay-coil not excited when in alarm condition). Default values: direct. #Al.1lb #Al.2lb AL1, AL2, latching and blocking function For each alarm it is possible to select one of the following functions: none none; Ltch acknowledge; bloc blocking; Lt.bL latching + blocking #Ltch ALARM ACKNOWLEDGE FUNCTION Once an alarm occurs, it is indicated on the display until it is acknowledged. To acknowledge an alarm press the key. After this operation, the alarm shuts off only when the alarm condition is no longer present. #bloc START-UP DISABLING Ramp down AL REF On Off Ramp up REF AL On Off Disable Start-up Disable Start-up SP Threshold = SP ± range 25
28 4 - Operations CONFIGURATION MENU 1 st part of the #Conf configuration code Fields i and l allow the selection of type and range of the primary input (IN1 page 16). Field m allows the selection of the function mode of the display (page 17). 2 nd part of the #Con2 configuration code Fields oand pselect alarm type and function (page 17). SENSOR BREAK ALARM FUNCTION During the configuration phase (page 17) set fileds o, p, to value 1. When the PV overcomes the sensor range limits, the sensor break alarm intervention is immediate. When the alarm is no longer present, the alarm stops ABSOLUTE ALARM During the configuration phase (page 17) set fields o and p to value 2 (actve high) or 3 (active low). On Off low range hy Alarm threshold On Off Active high Active low high range DEVIATION ALARM During the configuration phase (page 17) set fields o and p to value 4 (active high) or 5 (active low). On Off - low range REF hy On Off Active high Active low + high range Alarm threshold BAND ALARM During the configuration phase (page 17) set fields o and p to value 5 (active in) or 6 (active out). On Off full scale hy REF hy Alarm threshold On Active Off out full scale Active in AL1 RATE ALARM FUNCTION During the configuration phase (page 17) set fileds o, to value 8. When the changing rate of the PV connected to the alarm is higher than the specified threshold, AL1 is actvated. The changing rate can be set within the limits: digit/s. The alarm wil be activated in 1 second if the changin rate is higher than 1 digit/s. At lower rates the alarm activation time increases to up to 6 seconds for a limit change rate of 0.1 digit/s. 26
29 4 - Operations Engineering #Unit units This parameter allows the user to view the process in the desired engineering unit. When the instrument senses temperature, this parameter allows the convertion between Farenheit ( F) and centigrade ( C). All the engineering units available are listed at page 23 table 2. LINEAR SCALE PARAMETERS The parameters that follow aredisplayed only when, during the configuration phase, a linear input has been selected for IN1 (fileds i and l at page 16). IN1 Input number #in.1dd of decimals IN1 input low #in.1lo range IN1 input high #in.1hi range These parameters allow the user to set the operating range and the number of decimal point to be displayed for the primary (IN1) input. IN1 measure #in1.cn square root This parameter enables the calculation of the square root of the IN1 measure (sqrt = enabled, none = disabled) Cut-off square #CUt 1 root result This parameter allows the user to round to zero those results that are not meaningful. Setting range: Default value: 0. SERIAL COMMUNICATIONS PARAMETERS (OPTIONAL) The parameters that follow are displayed only when the optional communications board is installed in the instrument. Comunications #prot protocol Baud rate #baud Instrument #Addr serial address Values: Protocol: Modbus/Jbus. Baud rate: 200/2400/4800/9600 baud. Instrument serial address: Default values: Protocol: Jbus. Baud rate: 9600 baud. Instrument serial address: 1 SAFETY PARAMETERS #Code Access code This parameter allows the user to change the factory default password (Code = 33). If Code is set to 0 (zero), the access to the instrument is opern (no password needed). If 0 < Code 5000 only the Conf menu is protected. Codes higher than 5000 (5000 Code < 10000), protect all the 2 main menus of the instrument. 27
30 5 - Displays 5 DISPLAYS 5.1 DISPLAYING THE PROCESS VARIABLE 5.2 DISPLAYING THE CONFIGURATION CODES Operator mode in1 Unit Back to IN1 IN1 reading Engineering units (Table 2 page25) C Operator mode in1 Hard Con1 Con2 rel IN1 reading Hardware code st part of configuration index nd part of configuration index Software release #
31 6 COMMANDS 6 - Commands COMMANDS TO THE IDICATOR AND OPERATING PROCEDURE The commands can be entered in 2 ways: 6.1 KEYPAD see page SERIAL COMMUNICATIONS see the manual on this topic Keypad lock Outputs lock 29
32 6 - Commands 6.1 KEYPAD COMMANDS KEYPAD LOCK OUTPUTS LOCK To lock/unlock the keypad press and hold the keys í and è simultaneously for 2 seconds. To confirm the keypad lock/unlock the display flashes once. The keypad lock/unlock can also be achieved over serial communications. Operator mode The outputs are switched to the OFF status by pressing and holding the keys í and % simultaneously for 2 seconds. To confirm the output lock/unlock the display flashes once. To unlock the outputs press the keys simultaneously again The output lock/unlock can also be achieved over serial communications. Operator mode AThe keypad lock is retained in the event of power failure. Press simultaneously for 2 seconds AThe output lock is retained in the event of power failure. Press simultaneously for 2 seconds 30
33 7 TECHNICAL SPECIFICATIONS Features (at 25 C environmental temp.) Description Total configurability From keypad or serial communication the user selects: input type, type/functionality and display mode of the alarms IN1 Input (see pages 11,12 and 16) OP1 output OP2 output Common characteristics Accuracy Resistance thermometer (for T: R1+R2 must be <320Ω) Thermocouple DC input current (with 2.5Ω external shunt) DC input voltage A/D converter with resolution of 50,000 points Update measurement time: 0.2 seconds Sampling time: 0.5 seconds Input bias: digit Input filter: 1 30 seconds (0 = disabled) 0.25% ±1 digits for temperature sensors 0.1% ±1 digits (for mv and ma) Pt100Ω at 0 C (IEC 751) C/ F selectable L, J, T, K, S, R, B, N, E, W3, W5 (IEC 584) Rj >10MΩ, C/ F selectable 0 20mA, mA Rj >10MΩ 0 50mV, mV Rj >10MΩ SPDT relay, 2A/250Vac (4A/120Vac) for resistive load SPST Relay N.O., 2A/250Vac (4A/120Vac) for resistive load 2 or 3 wire connection Burnout (with any combination) Internal cold junction compensation con NTC Error 1 C/20 C ±0.5 C Burnout Burnout. Engineering units Conf. decimal point position Init. Scale Full Scale (min. range of 100 digits) 7 - Technical specification Between Vac the error is minimal Max. wire resistance: 20Ω max. (3 wires) Input drift: 0.35 C/10 Env. Temp. <0.35 C/10Ω Wire Res. Line: Input drift: 150Ω max. <2µV/ C Env. Temp. <5µV/10Ω Wire resistance Input drift: <0.1%/20 C Env. Temp. 31
34 7 - Technical specification Features (at 25 C environmental temp.) AL1 - AL2 alarms Serial comm. (option) Auxiliary Supply Operational Safety General characteristics 32 Description Hysteresis % c.s. Action Active high Active low Action type Changing rate threshold Deviation threshold Band threshold Absolute threshold digit/s ±range 0 range whole range Sensor break Special functions Acknowledge (latching), activation inhibit (blocking), OR function RS485 isolated, Modbus/Jbus protocol, 1200, 2400, 4800, 9600 bit/s, 3 wires +24Vdc ±20% 30mA max. - for external transmitter supply Measure input Detection of out of range, short circuit or sensor break with automatic activation of the safety strategies and alerts on display Parameters Parameter and configuration data are stored in a non-volatile memory for an unlimited time Access protection Password to access the configuration and parameter data, keypad lock, outputs lock Vac ( %) 50/60 Hz or Power supply 24Vac ( %), 50/60 Hz and (PTC protected) 24Vdc ( %) Power consumption 4W max. Safety Compliance to EN (IEC ), installation class 2 (2.5kV) pollution class 2, instrument class II Electromagnetic compatibility Compliance to the CE standards (see page 2) UL and cul Approvals File Protection EN60529 (IEC 529) IP65 front panel Dimensions 1 / 8 DIN - 96 x 48, depth 110 mm, weight 250 g approx.
35 Warranty 1 WARRANTY We warrant that the products will be free from defects in material and workmanship for 3 years from the date of delivery. The warranty above shall not apply for any failure caused by the use of the product not in accordance with the instructions contained in this manual. 33
36 Worldwide sales network ASCON S WORLDWIDE SALES NETWORK SUBSIDIARY FRANCE ASCON FRANCE Phone: +33 (0) Fax +33 (0) AGENCE EST Phone: +33 (3) Fax +33 (3) AGENCE SUD-EST Phone: +33 (0) Fax +33 (0) USA ASCON CORPORATION Phone: Fax DISTRIBUTORS ARGENTINA MEDITECNA S.R.L. Phone Fax FINLAND & ESTONIA THT CONTROL OY Phone Fax GERMANY MESA INDUSTRIE ELEKTRONIK GMBH Phone Fax GREECE CONTROL SYSTEM Phone Fax BRANCH OFFICE Phone Fax PORTUGAL REGIQUIPAMENTOS LDA Phone Fax SPAIN INTERBIL S.L. Phone Fax BRANCH OFFICE Phone Fax Phone Fax SWITZERLAND CONTROLTHERM GMBH Phone Fax TURKEY KONTROL SISTEMLERI LTD Phone Fax UNITED KINGDOM EUKERO CONTROLS LTD Phone Fax
37 ICONS TABLE Main universal input Digital input Digital input connected functions Icons table Thermocouple Isolated contact Auto/Manual RTD (Pt100) NPN open collector Run, Hold, Reset and program selection Delta Temp (2x RTD) TTL open collector PV hold ma and mv Setpoint Setpoint slopes inhibition Custom Local Output Frequency Stand-by SPST Relay Auxiliary input Keypad lock Triac Current transformer Outputs lock SPDT Relay ma Remote setpoint Start-up function ma Volt Remote setpoint Timer function ma mv Feedback potentiometer Memorized Logic Remote Setpoint programmer 35
38 36
Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line
BT. 2.9 M/E Process controller programmer /6 DIN - 48 x 48 mm gammadue series M line Advanced features, customizable and process adaptable High speed data aquisition and signal management. Efficent information
Heat-Cool temperature controller 1/8 DIN - 48 x 96 mm gammadue series X1 line
BT.. X/E Heat-Cool temperature controller /8 IN - 8 x 96 mm gammadue series X line Cost effective solutions Ideal for Heat/Cool control, with the capability to check the load current by current transformer.
M3 line User manual M.I.U. M3-5/04.06 Cod. J30-478-1AM3 IE
Temperature Controller 1 / 16 DIN - 48 x 48 ASCON spa ISO 9001 Certified M line c User manual M.I.U. M -5/04.06 Cod. J0-478-1AM IE C UL US LISTED ASCON spa via Falzarego, 9/11 20021 Bollate (Milan) Italy
Process controller with PROFIBUS DP and Modbus Master/Slave 1/4 DIN - 96 x 96 mm gammadue series Q5 line
BT. 2.3 Q/E Process controller with PROFIBUS DP and Modbus Master/Slave / DIN - 96 x 96 mm gammadue series Q line Sophisticated multifunction process controller with high level communications By its three
Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C
F4 Process Controller Installation and Operation Guide SAFETY ALERTS The symbols below are used on the equipment and throughout this document to draw the user s attention to important operational and safety
X3 line. Double action controller with analogue output 1 / 8 DIN - 48 x 96 ISO 9001. ASCON spa. Certified. ASCON spa
Double action controller with analogue output 1 / 8 DIN - 48 x 96 ASCON spa ISO 9001 Certified X3 line User Manual M.I.U.X3-4/04.02 c Cod. J30-478-1AX3 IE C UL LISTED US ASCON spa 20021 Bollate (Milan)
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Process controller with PROFIBUS DP and Modbus Master/Slave 1/8 DIN - 48 x 96 mm gammadue series X5 line
BT. 2.22 X/E Process controller with PROFIBUS DP and Modbus Master/Slave /8 DIN - 48 x 96 mm gammadue series X line Sophisticated multifunction process controller with high level communications By its
Panel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
Temperature Transmitters ZTT series
BT.11.13 ZT/E Transmitters ZTT series The ZTT Series transmitters accept the most commonly used temperature sensors (TC and RTD), as well as mv and slidewire feedback signals. All ZTT transmitters provide
FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.
TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
ZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
J TB/TW Temperature limiter, temperature monitor
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: [email protected] Internet: www.jumo.net
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Auto-tune PID. Temperature Controller BRAINCHILD FEATURES
Auto-tune PID Temperature Controller FEATURES Easy-to-use Fuzzy modified PID heat & cool control Fast A-D sampling rate (5 times/s) Universal input (PT100, thermocouple) with high accuracy 18-bit A-D Analog
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) 876-4444 Tel: (203) 426-7700 Fax: (203) 426-7800 www.walkeremd.
Eclipse Series Digital Panel Meters Installation and Operation Manual Number 57700-900-05 Models: 5770X-40X - DC Volts 5770X-4X - AC Volts 5770X-42X - DC Amps 5770X-43X - AC Amps 5770X-44X - 5A AC 5770X-45X
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)
February 2015 February 2015 Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC) This document describes how to connect an electricity meter to a SolarEdge device (inverters,
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies
25.2W/in 3 power density Internal ORing MOSFET & Current Share Climate Savers Computing efficiency standards Up to 8000W in 1U rack Single and dual output 1U racks PMBus option HFE1600 Series 1600W 1U
Preliminary. Dual-line FLOW rate/totalizers. Pr ovu Model PD6200 Analog Input. Pr ovu Model PD6300 Pulse Input. Analog Inputs.
Dual-line FLOW rate/totalizers Pr ovu PD6200 Analog Input ProVu Se r i e s Pr ovu PD6300 Pulse Input Analog Inputs 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, and ±10 V Inputs Isolated 24 VDC @ 200 ma Transmitter
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Multifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
Thyristor power units and Solid state contactors. TC2000 series. Two-phase control of a three-phase load or control of two single-phase loads
Thyristor power units and Solid state contactors TC2000 series Two-phase control of a three-phase load or control of two single-phase loads User Manual Copyright Eurotherm Automation 1995 All rights reserved.
T7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012
Technical Information THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012 GENERAL DESCRIPTION THYRISTORS T1-1PH is a full digital and universal
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Product overview The Tracer ZN517 controller is a field-installed, application-specific controller that provides directdigital
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
T0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
CQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
ACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
LDG DTS-4/4R Desktop Coaxial Switch / Remote
LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 [email protected] www.ldgelectronics.com
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
TC-9102 Series Surface Mount Temperature Controllers
TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may
WD-AMX Water Detection Controllers
Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation
NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module
NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module 1. General Description 1 2. General Warnings 1 3. Interface 2 4. Temp Alarms Setting 3 5. Programming 3 6. Light Management 4 7. Installation and
Model SRMD Setra Remote Monitoring Display
Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for
Problem / Solution. The problem:
Problem / Solution Solar Photovoltaic (PV) technology has shown significant development in recent years and this has led to many UK homeowners investing in Solar PV installations. Solar electricity is
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
Meter Relays. 077 Series Analogue Meter Relays. Features. Applications
077 Series Analogue Features Monitors and controls any variable which can be converted to an A.C. or D.C. signal. Rugged, shock and vibration resistant design Indicator, relays and power unit in one housing
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
Bulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM
TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution
2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:
COMMUNICATION INSTRUCTION MANUAL TEMPERATURE CONTROLLER KT4, KT8 and KT9 No.KTC1E6 2009.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.
Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation.
PRELIMINARY TECHNICAL INFORMATION Three-phase Digital SCR Firing Board HIGHLIGHTS - Up to 480 V AC input supply voltage - Up to 700 V AC sync input - DSP controlled - Digital or analog input signaling
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
Manual Ranging MultiMeter
Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
T-100-R Installation Guide
T-100-R Installation Guide Table of Contents Page 2 Overview T-100-R Z-Wave Thermostat 3-4 Installation HVAC System Setup 6 Installer Settings Menu Items 7-9 Installer Settings Summary 10-11 Wiring Standard
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
SECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK
Security Door Controls 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: [email protected] INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
Contactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
www.sebury.com.cn Digital Keypad Use s Manual
K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power
Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal
IntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new
SMART SENSOR COLLECTION
TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
ABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions