FAN SPEED AIR SWING SET CANCEL FAN AIR SWING SET CANCEL WARNING

Size: px
Start display at page:

Download "FAN SPEED AIR SWING SET CANCEL FAN AIR SWING SET CANCEL WARNING"

Transcription

1 AUT O HE AT COOL DRY AUT O HE AT COOL DRY FAN SP E ED FAN SPEED AC AC AIR SWING SE T CHE CK CLOCK RE SE T AIR SWING SE T CHE CK CLOCK RE SE T FAN SPEED AIR SWING RC RC Order No: PAPAMY32039CE (YE9/2QKE) (UE9/2QKE) (UE8QKE) Indoor Unit CS-YE9QKE CS-YE2QKE CS-UE9QKE CS-UE2QKE CS-UE8QKE Outdoor Unit CU-YE9QKE CU-YE2QKE CU-UE9QKE CU-UE2QKE CU-UE8QKE Destination Europe E.Europe Turkey OFF/ON MODE TEMP TIMER ON SET 2 3 OFF CANCEL FAN SPEED AIR SWING OFF/ON MODE TEMP TIMER ON SET 2 3 OFF CANCEL WARNING This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service or repair the products dealt with in this service information by anyone else could result in serious injury or death. PRECAUTION OF LOW TEMPERATURE In order to avoid frostbite, be assured of no refrigerant leakage during the installation or repairing of refrigerant circuit. Panasonic Corporation 203.

2 TABLE OF CONTENTS. Safety Precautions Specifications Features Location of Controls and Components Indoor Unit Outdoor Unit Remote Control Dimensions Indoor Unit & Remote Control Outdoor Unit Refrigeration Cycle Diagram Block Diagram CS-YE9QKE CU-YE9QKE CS-YE2QKE CU-YE2QKE CS-UE9QKE CU-UE9QKE CS-UE2QKE CU-UE2QKE CS-UE8QKE CU-UE8QKE Wiring Connection Diagram Indoor Unit Outdoor Unit Electronic Circuit Diagram Indoor Unit Outdoor Unit Printed Circuit Board Indoor Unit Outdoor Unit Installation Instruction Select the Best Location Indoor Unit Outdoor Unit Operation Control Basic Function Indoor Fan Motor Operation Outdoor Fan Motor Operation Airflow Direction ON Timer Control OFF Timer Control Auto Restart Control Indication Panel Protection Control Protection Control For All Operations Protection Control For Cooling & Soft Dry Operation Protection Control For Heating Operation Servicing Mode Auto OFF/ON Button Remote Control Button Troubleshooting Guide Refrigeration Cycle System Relationship Between The Condition Of The Air Conditioner And Pressure And Electric Current Breakdown Self Diagnosis Function Error Codes Table Self-diagnosis Method Disassembly and Assembly Instructions Indoor Electronic Controllers, Cross Flow Fan and Indoor Fan Motor Removal Procedures Indoor Electronic Controllers, Cross Flow Fan and Indoor Fan Motor Removal Procedures Outdoor Electronic Controller Removal Procedure Technical Data Cool Mode Performance Data Heat Mode Performance Data Service Data Cool Mode Outdoor Air Temperature Characteristic Heat Mode Outdoor Air Temperature Characteristic Piping Length Correction Factor Exploded View and Replacement Parts List09 9. Indoor Unit Outdoor Unit... 7

3 . Safety Precautions Read the following SAFETY PRECAUTIONS carefully before perform any servicing. Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model installed. The caution items stated here must be followed because these important contents are related to safety. The meaning of each indication used is as below. Incorrect installation or servicing due to ignoring of the instruction will cause harm or damage, and the seriousness is classified by the following indications. WARNING CAUTION This indication shows the possibility of causing death or serious injury. This indication shows the possibility of causing injury or damage to properties. The items to be followed are classified by the symbols: This symbol denotes item that is PROHIBITED from doing. Carry out test run to confirm that no abnormality occurs after the servicing. Then, explain to user the operation, care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.. Do not modify the machine, part, material during repairing service. WARNING 2. If wiring unit is supplied as repairing part, do not repair or connect the wire even only partial wire break. Exchange the whole wiring unit. 3. Do not wrench the fasten terminal. Pull it out or insert it straightly. 4. Engage dealer or specialist for installation and servicing. If installation of servicing done by the user is defective, it will cause water leakage, electrical shock or fire. 5. Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electric shock or fire Use the attached accessories parts and specified parts for installation and servicing. Otherwise, it will cause the set to fall, water leakage, fire or electrical shock. Install at a strong and firm location which is able to withstand the set s weight. If the strength is not enough or installation is not properly done, the set will drop and cause injury. For electrical work, follow the local national wiring standard, regulation and the installation instruction. An independent circuit and single outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire. This equipment is strongly recommended to install with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD). Otherwise, it may cause electrical shock and fire in case equipment breakdown or insulation breakdown. Do not use joint cable for indoor / outdoor connection cable. Use the specified Indoor/Outdoor connection cable, refer to installation instruction CONNECT THE CABLE TO THE INDOOR UNIT and connect tightly for indoor / outdoor connection. Clamp the cable so that no external force will be acted on the terminal. If connecting or fixing is not perfect, it will cause heat up or fire at the connection. Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause heat-up or fire at the connection point of terminal, fire or electrical shock. When install or relocate air conditioner, do not let any substance other than the specified refrigerant, eg. air etc. mix into refrigeration cycle (piping). (Mixing of air etc. will cause abnormal high pressure in refrigeration cycle and result in explosion, injury etc.). Do not install outdoor unit near handrail of veranda. When installing air-conditioner unit at veranda of high rise building, child may climb up to outdoor unit and cross over the handrail and causing accident. This equipment must be properly earthed. Earth line must not be connected to gas pipe, water pipe, earth of lightning rod and telephone. Otherwise, it may cause electric shock in case equipment breakdown or insulation breakdown. 5. Keep away from small children, the thin film may cling to nose and mouth and prevent breathing Do not use unspecified cord, modified cord, joint cord or extension cord for power supply cord. Do not share the single outlet with other electrical appliances. Poor contact, poor insulation or over current will cause electrical shock or fire. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare may break and cause refrigerant gas leakage. For R40A model, use piping, flare nut and tools which is specified for R40A refrigerant. Using of existing (R22) piping, flare nut and tools may cause abnormally high pressure in the refrigerant cycle (piping), and possibly result in explosion and injury. Thickness or copper pipes used with R40A must be more than 0.8 mm. Never use copper pipes thinner than 0.8 mm. It is desirable that the amount of residual oil less than 40 mg/0 m. During installation, install the refrigerant piping properly before run the compressor. (Operation of compressor without fixing refrigeration piping and valves at opened condition will caused suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc). 3

4 WARNING During pump down operation, stop the compressor before remove the refrigeration piping. (Removal of compressor while compressor is operating and valves are opened will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc.) After completion of installation or service, confirm there is no leakage or refrigerant gas. It may generate toxic gas when the refrigerant contacts with fire. 22. Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when refrigerant contacts with fire. 23. Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury. 24. Must not use other parts except original parts described in catalog and manual. 25. Using of refrigerant other than the specified type may cause product damage, burst and injury etc. CAUTION Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of the unit, it may cause fire. Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the furniture. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare may break and cause refrigerant gas leakage. 4. Do not touch outdoor unit air inlet and aluminium fin. It may cause injury. 5. Select an installation location which is easy for maintenance Pb free solder has a higher melting point than standard solder; typically the melting point is 50 F 70 F (30 C 40 C) higher. Please use a high temperature solder iron. In case of the soldering iron with temperature control, please set it to 700 ± 20 F (370 ± 0 C). Pb free solder will tend to splash when heated too high (about 00 F / 600 C). Power supply connection to the room air conditioner. Use power supply cord 3.5 mm² (.0 ~.75HP), mm² (2.0 ~ 2.5HP) type designation IEC 57 or heavier cord. Connect the power supply cord of the air conditioner to the mains using one of the following method. Power supply point should be in easily accessible place for power disconnection in case of emergency. In some countries, permanent connection of this air conditioner to the power supply is prohibited. ) Power supply connection to the receptacle using power plug. Use an approved 5/6A (.0 ~.75HP), 6A (2.0HP), 20A (2.5HP) power plug with earth pin for the connection to the socket. 2) Power supply connection to a circuit breaker for the permanent connection. Use an approved 6A (.0 ~ 2.0HP), 20A (2.5HP) circuit breaker for the permanent connection. It must be a double pole switch with a minimum 3.0 mm contact gap. Do not release refrigerant during piping work for installation, servicing, reinstallation and during repairing a refrigerant parts. Take care of the liquid refrigerant, it may cause frostbite. 9. Installation or servicing work: It may need two people to carry out the installation or servicing work. 0. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.. Do not sit or step on the unit, you may fall down accidentally. 2. Do not touch the sharp aluminium fins or edges of metal parts. If you are required to handle sharp parts during installation or servicing, please wear hand glove. Sharp parts may cause injury. 4

5 2. Specifications Cooling Heating Model Indoor CS-YE9QKE CS-YE2QKE Outdoor CU-YE9QKE CU-YE2QKE Performance Test Condition EUROVENT EUROVENT Power Supply Capacity Phase, Hz Single, 50 Single, 50 V Min. Mid. Max. Min. Mid. Max. kw BTU/h kcal/h Running Current A Input Power W k k.28k Annual Consumption kwh ErP ErP EER W/W BTU/hW kcal/hw Pdesign kw SEER (W/W) Annual Consumption kwh Class A+ A+ Power Factor % Indoor Noise Outdoor Noise Capacity db-a (H/L/Q-Lo) 4 / 26 / / 30 / 22 Power Level db db-a Power Level db kw BTU/h kcal/h Running Current A Input Power W k 200.0k.47k COP W/W BTU/hW kcal/hw Pdesign kw Tbivalent C -0-0 SCOP (W/W) Annual Consumption kwh Class A A Power Factor % Indoor Noise Outdoor Noise db-a (H/L/Q-Lo) 4 / 27 / / 33 / 25 Power Level db db-a Power Level db Low Temp. : Capacity (kw) / I.Power (W) / COP 2.97 /.04k / /.30k / 2.85 Extr Low Temp. : Capacity (kw) / I.Power (W) / COP 2.66 /.2k / /.4k / 2.27 Max Current (A) / Max Input Power (W) 5.3 /.8k 6.7 /.47k Starting Current (A)

6 Compressor Indoor Fan Outdoor Fan Speed Speed Indoor Airflow Outdoor Airflow Refrigeration Cycle Dimension Model Indoor CS-YE9QKE CS-YE2QKE Outdoor CU-YE9QKE CU-YE2QKE Type Hermetic Motor Hermetic Motor Motor Type Brushless (6-poles) Brushless (6-poles) Output Power W Type Cross-Flow Fan Cross-Flow Fan Material ASG20K ASG20K Motor Type DC / Transistor (8 poles) DC / Transistor (8 poles) Input Power W Output Power W QLo Lo Me Hi Cool rpm Heat rpm Cool rpm Heat rpm Cool rpm Heat rpm Cool rpm Heat rpm Type Propeller Fan Propeller Fan Material PP PP Motor Type AC / Induction (6 poles) AC / Induction (6 poles) Input Power W Output Power W Hi Cool rpm Heat rpm Moisture Removal L/h (Pt/h).5 (3.2) 2.0 (4.2) QLo Lo Me Hi Hi Cool m 3 /min (ft 3 /min) 5.74 (203) 5.69 (20) Heat m 3 /min (ft 3 /min) 7.03 (248) 6.79 (240) Cool m 3 /min (ft 3 /min) 6.68 (236) 7.59 (268) Heat m 3 /min (ft 3 /min) 7.62 (269) 8.85 (33) Cool m 3 /min (ft 3 /min) 9.22 (326) 9.94 (35) Heat m 3 /min (ft 3 /min) 0.22 (36) 0.50 (37) Cool m 3 /min (ft 3 /min).7 (45) 2.3 (435) Heat m 3 /min (ft 3 /min) 2.8 (450) 2.8 (450) Cool m 3 /min (ft 3 /min) 32. (35) 3.0 (095) Heat m 3 /min (ft 3 /min) 3.2 (00) 3.0 (095) Control Device Expansion Valve Expansion Valve Refrigerant Oil cm 3 FV50S (320) FV50S (320) Refrigerant Type g (oz) R40A, 850 (30.0) R40A,.00k (35.3) Height (I/D / O/D) mm (inch) 290 (-7/6) / 542 (2-/32) 290 (-7/6) / 542 (2-/32) Width (I/D / O/D) mm (inch) 870 (34-9/32) / 780 (30-23/32) 870 (34-9/32) / 780 (30-23/32) Depth (I/D / O/D) mm (inch) 24 (8-7/6) / 289 (-3/32) 24 (8-7/6) / 289 (-3/32) Weight Net (I/D / O/D) kg (lb) 9 (20) / 3 (68) 9 (20) / 33 (73) 6

7 Piping Model Indoor CS-YE9QKE CS-YE2QKE Outdoor CU-YE9QKE CU-YE2QKE Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (/4) / 9.52 (3/8) 6.35 (/4) / 9.52 (3/8) Standard length m (ft) 5.0 (6.4) 5.0 (6.4) Length range (min max) m (ft) 3 (9.8) ~ 5 (49.2) 3 (9.8) ~ 5 (49.2) I/D & O/D Height different m (ft) 5.0 (49.2) 5.0 (49.2) Additional Gas Amount g/m (oz/ft) 20 (0.2) 20 (0.2) Length for Additional Gas m (ft) 7.5 (24.6) 7.5 (24.6) Drain Hose Indoor Heat Exchanger Outdoor Heat Exchanger Air Filter Inner Diameter mm Length mm Fin Material Aluminium (Pre Coat) Aluminium (Pre Coat) Fin Type Slit Fin Slit Fin Row Stage FPI Size (W H L) mm Fin Material Aluminium (Pre Coat) Aluminium (Pre Coat) Fin Type Corrugated Fin Corrugated Fin Row Stage FPI Size (W H L) mm :684 Material Polypropelene Polypropelene Type One-touch One-touch Power Supply Indoor Indoor Power Supply Cord A Nil Nil Thermostat Nil Nil Protection Device Nil Nil Indoor Operation Range Outdoor Operation Range Cooling Heating Cooling Heating Dry Bulb Wet Bulb Dry Bulb Wet Bulb Maximum C Minimum C 6 6 Maximum C Minimum C 6 6 Maximum C Minimum C 5 5 Maximum C Minimum C Cooling capacities are based on indoor temperature of 27 C Dry Bulb (80.6 F Dry Bulb), 9.0 C Wet Bulb (66.2 F Wet Bulb) and outdoor air temperature of 35 C Dry Bulb (95 F Dry Bulb), 24 C Wet Bulb (75.2 F Wet Bulb) 2. Heating capacities are based on indoor temperature of 20 C Dry Bulb (68 F Dry Bulb) and outdoor air temperature of 7 C Dry Bulb (44.6 F Dry Bulb), 6 C Wet Bulb (42.8 F Wet Bulb) 3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20 C, outdoor 2/ C. 4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20 C, outdoor -7/-8 C. 5. Standby power consumption 2.0W (when switched OFF by remote control, except under self-protection control). 6. Specifications are subjected to change without prior notice for further improvement. 7. Maximum heating capacity shown are the values based on powerful operation. 8. If the EUROVENT Certified models can be operated under the extra-low temperature condition, -7 C DB and -8 C WB temperature with rated voltage 230V shall be used. 9. The annual consumption is calculated by multiplying the input power by an average of 500 hours per year in cooling mode. 0. SEER and SCOP classification is at 230V only in accordance with EN For heating, SCOP indicates the value of only Average heating season. Other fiche data indicates in an attached sheet. 7

8 Model Indoor CS-UE9QKE CS-UE2QKE Outdoor CU-UE9QKE CU-UE2QKE Performance Test Condition EUROVENT EUROVENT Cooling Heating Power Supply Capacity Phase, Hz Single, 50 Single, 50 V Min. Mid. Max. Min. Mid. Max. kw BTU/h kcal/h Running Current A Input Power W k k.28k Annual Consumption kwh ErP ErP EER W/W BTU/hW kcal/hw Pdesign kw SEER (W/W) Annual Consumption kwh Class A+ A+ Power Factor % Indoor Noise Outdoor Noise Capacity db-a (H/L/Q-Lo) 4 / 26 / / 30 / 22 Power Level db db-a Power Level db kw BTU/h kcal/h Running Current A Input Power W k 200.0k.47k COP W/W BTU/hW kcal/hw Pdesign kw Tbivalent C -0-0 SCOP (W/W) Annual Consumption kwh Class A A Power Factor % Indoor Noise Outdoor Noise db-a (H/L/Q-Lo) 4 / 27 / / 33 / 25 Power Level db db-a Power Level db Low Temp. : Capacity (kw) / I.Power (W) / COP 2.97 /.04k / /.30k / 2.85 Extr Low Temp. : Capacity (kw) / I.Power (W) / COP 2.66 /.2k / /.4k / 2.27 Max Current (A) / Max Input Power (W) 5.3 /.8k 6.7 /.47k Starting Current (A)

9 Compressor Indoor Fan Outdoor Fan Speed Speed Indoor Airflow Outdoor Airflow Refrigeration Cycle Dimension Model Indoor CS-UE9QKE CS-UE2QKE Outdoor CU-UE9QKE CU-UE2QKE Type Hermetic Motor Hermetic Motor Motor Type Brushless (6-poles) Brushless (6-poles) Output Power W Type Cross-Flow Fan Cross-Flow Fan Material ASG20K ASG20K Motor Type DC / Transistor (8 poles) DC / Transistor (8 poles) Input Power W Output Power W QLo Lo Me Hi Cool rpm Heat rpm Cool rpm Heat rpm Cool rpm Heat rpm Cool rpm Heat rpm Type Propeller Fan Propeller Fan Material PP PP Motor Type DC (8 poles) DC (8 poles) Input Power W Output Power W Hi Cool rpm Heat rpm Moisture Removal L/h (Pt/h).5 (3.2) 2.0 (4.2) QLo Lo Me Hi Hi Cool m 3 /min (ft 3 /min) 5.74 (203) 5.69 (20) Heat m 3 /min (ft 3 /min) 7.03 (248) 6.79 (240) Cool m 3 /min (ft 3 /min) 6.68 (236) 7.59 (268) Heat m 3 /min (ft 3 /min) 7.62 (269) 8.85 (33) Cool m 3 /min (ft 3 /min) 9.22 (326) 9.94 (35) Heat m 3 /min (ft 3 /min) 0.22 (36) 0.50 (37) Cool m 3 /min (ft 3 /min).7 (45) 2.3 (435) Heat m 3 /min (ft 3 /min) 2.8 (450) 2.8 (450) Cool m 3 /min (ft 3 /min) 32. (35) 3.0 (095) Heat m 3 /min (ft 3 /min) 3.2 (00) 3.0 (095) Control Device Expansion Valve Expansion Valve Refrigerant Oil cm 3 FV50S (320) FV50S (320) Refrigerant Type g (oz) R40A, 850 (30.0) R40A,.00k (35.3) Height (I/D / O/D) mm (inch) 290 (-7/6) / 542 (2-/32) 290 (-7/6) / 542 (2-/32) Width (I/D / O/D) mm (inch) 870 (34-9/32) / 780 (30-23/32) 870 (34-9/32) / 780 (30-23/32) Depth (I/D / O/D) mm (inch) 24 (8-7/6) / 289 (-3/32) 24 (8-7/6) / 289 (-3/32) Weight Net (I/D / O/D) kg (lb) 9 (20) / 3 (68) 9 (20) / 33 (73) 9

10 Piping Model Indoor CS-UE9QKE CS-UE2QKE Outdoor CU-UE9QKE CU-UE2QKE Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (/4) / 9.52 (3/8) 6.35 (/4) / 9.52 (3/8) Standard length m (ft) 5.0 (6.4) 5.0 (6.4) Length range (min max) m (ft) 3 (9.8) ~ 5 (49.2) 3 (9.8) ~ 5 (49.2) I/D & O/D Height different m (ft) 5.0 (49.2) 5.0 (49.2) Additional Gas Amount g/m (oz/ft) 20 (0.2) 20 (0.2) Length for Additional Gas m (ft) 7.5 (24.6) 7.5 (24.6) Drain Hose Indoor Heat Exchanger Outdoor Heat Exchanger Air Filter Inner Diameter mm Length mm Fin Material Aluminium (Pre Coat) Aluminium (Pre Coat) Fin Type Slit Fin Slit Fin Row Stage FPI Size (W H L) mm Fin Material Aluminium (Pre Coat) Aluminium (Pre Coat) Fin Type Corrugated Fin Corrugated Fin Row Stage FPI Size (W H L) mm :684 Material Polypropelene Polypropelene Type One-touch One-touch Power Supply Indoor Indoor Power Supply Cord A Nil Nil Thermostat Nil Nil Protection Device Nil Nil Indoor Operation Range Outdoor Operation Range Cooling Heating Cooling Heating Dry Bulb Wet Bulb Dry Bulb Wet Bulb Maximum C Minimum C 6 6 Maximum C Minimum C 6 6 Maximum C Minimum C 5 5 Maximum C Minimum C Cooling capacities are based on indoor temperature of 27 C Dry Bulb (80.6 F Dry Bulb), 9.0 C Wet Bulb (66.2 F Wet Bulb) and outdoor air temperature of 35 C Dry Bulb (95 F Dry Bulb), 24 C Wet Bulb (75.2 F Wet Bulb) 2. Heating capacities are based on indoor temperature of 20 C Dry Bulb (68 F Dry Bulb) and outdoor air temperature of 7 C Dry Bulb (44.6 F Dry Bulb), 6 C Wet Bulb (42.8 F Wet Bulb) 3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20 C, outdoor 2/ C. 4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20 C, outdoor -7/-8 C. 5. Standby power consumption 2.0W (when switched OFF by remote control, except under self-protection control). 6. Specifications are subjected to change without prior notice for further improvement. 7. Maximum heating capacity shown are the values based on powerful operation. 8. If the EUROVENT Certified models can be operated under the extra-low temperature condition, -7 C DB and -8 C WB temperature with rated voltage 230V shall be used. 9. The annual consumption is calculated by multiplying the input power by an average of 500 hours per year in cooling mode. 0. SEER and SCOP classification is at 230V only in accordance with EN For heating, SCOP indicates the value of only Average heating season. Other fiche data indicates in an attached sheet. 0

11 Model Indoor Outdoor CS-UE8QKE CU-UE8QKE Cooling Heating Performance Test Condition Power Supply Capacity EUROVENT Phase, Hz Single, 50 V 230 Min. Mid. Max. kw BTU/h kcal/h Running Current A 6.90 Input Power W k.75k Annual Consumption kwh 770 ErP ErP EER W/W BTU/hW kcal/hw Pdesign kw 5.0 SEER (W/W) 6.5 Annual Consumption Class kwh 269 Power Factor % 97 Indoor Noise Outdoor Noise Capacity A++ db-a (H/L) 44 / 37 Power Level db 60 db-a 48 Power Level db 63 kw BTU/h kcal/h Running Current A 6.70 Input Power W k 2.30k COP W/W BTU/hW kcal/hw Pdesign kw 4.0 Tbivalent C -0 SCOP (W/W) 4.3 Annual Consumption kwh 302 Class A+ Power Factor % 95 Indoor Noise Outdoor Noise db-a (H/L) 44 / 37 Power Level db 60 db-a 49 Power Level db 64 Low Temp. : Capacity (kw) / I.Power (W) / COP 5.58 / 2.04k / 2.74 Extr Low Temp. : Capacity (kw) / I.Power (W) / COP 4.79 / 2.09k / 2.29 Max Current (A) / Max Input Power (W) 0. / 2.30k Starting Current (A) 6.90

12 Compressor Indoor Fan Outdoor Fan Speed Speed Indoor Airflow Outdoor Airflow Refrigeration Cycle Dimension Model Type Motor Type Indoor Outdoor CS-UE8QKE CU-UE8QKE Hermetic Motor Brushless (4-poles) Output Power W 900 Type Material Motor Type Cross-Flow Fan ASG20K DC / Transistor (8 poles) Input Power W 94.8 Output Power W 40 Lo Me Hi Type Material Motor Type Cool rpm 960 Heat rpm 070 Cool rpm 080 Heat rpm 90 Cool rpm 200 Heat rpm 30 Propeller Fan PP DC (8 poles) Input Power W Output Power W 40 Hi Cool rpm 860 Heat rpm 850 Moisture Removal L/h (Pt/h) 2.8 (5.9) Lo Me Hi Hi Control Device Cool m 3 /min (ft 3 /min) 2.65 (447) Heat m 3 /min (ft 3 /min) 4.25 (503) Cool m 3 /min (ft 3 /min) 4.45 (50) Heat m 3 /min (ft 3 /min) 6.05 (567) Cool m 3 /min (ft 3 /min) 6.30 (575) Heat m 3 /min (ft 3 /min) 7.90 (630) Cool m 3 /min (ft 3 /min) 34.4 (25) Heat m 3 /min (ft 3 /min) 34.0 (200) Expansion Valve Refrigerant Oil cm 3 FV50S (450) Refrigerant Type g (oz) R40A,.43k (50.5) Height (I/D / O/D) mm (inch) 290 (-7/6) / 622 (24-/2) Width (I/D / O/D) mm (inch) 070 (42-5/32) / 824 (32-5/32) Depth (I/D / O/D) mm (inch) 240 (9-5/32) / 299 (-25/32) Weight Net (I/D / O/D) kg (lb) 2 (26) / 38 (84) 2

13 Piping Model Indoor Outdoor CS-UE8QKE CU-UE8QKE Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (/4) / 2.70 (/2) Standard length m (ft) 5.0 (6.4) Length range (min max) m (ft) 3 (9.8) ~ 5 (49.2) I/D & O/D Height different m (ft) 5.0 (49.2) Additional Gas Amount g/m (oz/ft) 20 (0.2) Length for Additional Gas m (ft) 7.5 (24.6) Drain Hose Indoor Heat Exchanger Outdoor Heat Exchanger Air Filter Inner Diameter mm 6.7 Length mm 650 Fin Material Fin Type Aluminium (Pre Coat) Slit Fin Row Stage FPI Size (W H L) mm Fin Material Fin Type Aluminium (Pre Coat) Corrugated Fin Row Stage FPI Size (W H L) mm :827.7 Material Type Power Supply Polypropelene One-touch Power Supply Cord A Nil Thermostat Protection Device Indoor Operation Range Outdoor Operation Range Cooling Heating Cooling Heating Dry Bulb Indoor Nil Nil Wet Bulb Maximum C Minimum C 6 Maximum C 30 Minimum C 6 Maximum C Minimum C 5 Maximum C 24 8 Minimum C Cooling capacities are based on indoor temperature of 27 C Dry Bulb (80.6 F Dry Bulb), 9.0 C Wet Bulb (66.2 F Wet Bulb) and outdoor air temperature of 35 C Dry Bulb (95 F Dry Bulb), 24 C Wet Bulb (75.2 F Wet Bulb) 2. Heating capacities are based on indoor temperature of 20 C Dry Bulb (68 F Dry Bulb) and outdoor air temperature of 7 C Dry Bulb (44.6 F Dry Bulb), 6 C Wet Bulb (42.8 F Wet Bulb) 3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20 C, outdoor 2/ C. 4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20 C, outdoor -7/-8 C. 5. Standby power consumption 2.0W (when switched OFF by remote control, except under self-protection control). 6. Specifications are subjected to change without prior notice for further improvement. 7. Maximum heating capacity shown are the values based on powerful operation. 8. If the EUROVENT Certified models can be operated under the extra-low temperature condition, -7 C DB and -8 C WB temperature with rated voltage 230V shall be used. 9. The annual consumption is calculated by multiplying the input power by an average of 500 hours per year in cooling mode. 0. SEER and SCOP classification is at 230V only in accordance with EN For heating, SCOP indicates the value of only Average heating season. Other fiche data indicates in an attached sheet. 3

14 3. Features Inverter Technology o Wider output power range o Energy saving o Quick Cooling o Quick Heating o More precise temperature control Environment Protection o Non-ozone depletion substances refrigerant (R40A) Long Installation Piping o CS/CU-YE9/2QKE, CS/CU-UE9/2/8QKE, long piping up to 5 meters Easy to use remote control Quality Improvement o Random auto restart after power failure for safety restart operation o Gas leakage protection o Prevent compressor reverse cycle o Inner protector to protect compressor Serviceability Improvement o Breakdown Self Diagnosis function 4

15 POWER TIMER 4. Location of Controls and Components 4. Indoor Unit Anti-Bacterial filter Front panel Air Filters Auto OFF/ON button Use when remote control is misplaced or malfunction occurs. Aluminium Fin Horizontal Airflow direction louver Do not adjust by hand. 4.2 Outdoor Unit Vertical Airflow direction louver Do not adjust by hand. Remote Control receiver POWER TIMER INDICATOR (Green) (Orange) 4.3 Remote Control Transmitter Remote control display AUTO HEAT COOL DRY FAN SPEED AIR SWING AUTO HEAT COOL DRY FAN SPEED AIR SWING OFF/ON OFF/ON Operation mode Temperature setting MODE TEMP AIR SWING FAN SPEED TIMER ON SET Airflow direction selection Fan speed selection MODE TEMP FAN SPEED TIMER ON AIR SWING SET Airflow direction selection 2 3 Timer setting 2 3 Check OFF AC CANCEL RC Clock setting OFF AC CANCEL RC SET CHECK CLOCK RESET SET CHECK CLOCK RESET (YE9/2QKE, UE9/2QKE) (UE8QKE) 5

16 5. Dimensions 5. Indoor Unit & Remote Control 5.. CS-YE9QKE CS-YE2QKE CS-UE9QKE CS-UE2QKE <Top View> <Side View> Air intake direction <Front View> <Side View> 24 Left piping hole Air outlet direction ~2 ~2 870 <Bottom View> <Remote Control> <Rear View> <Remote Control Holder> Right piping hole (4 ~ 6) Liquid side Gas side 5 Relative position between the indoor unit and the installation plate <Front View> Installation plate Indoor unit external dimensions line Left piping hole Right piping hole Unit : mm 6

17 AUT O HE AT COOL DRY FAN SPEED AC AIR SWING SET CHECK CLOCK RESET RC 5..2 CS-UE8QKE <Top View> <Side View> Air intake direction <Front View> <Side View> Left piping hole Air outlet direction ~2 070 ~2 Right piping hole <Bottom View> <Remote Control Transmitter> 47 8 FAN SPEED AIR SWING MODE OFF/ON TEMP <Back View> TIMER ON SET 2 3 OFF CANCEL <Remote Control Holder> 40 (4~6) 6.5 Relative position between the indoor unit and the installation plate <Front View> Installation plate Indoor unit external dimensions line Left piping hole Right piping hole Unit : mm

18 5.2 Outdoor Unit 5.2. CU-YE9QKE CU-YE2QKE CU-UE9QKE CU-UE2QKE Space necessary for installation 24.4 <Top View> (04.7) mm 00 mm 000 mm Anchor Bolt Pitch <Side View> <Front View> <Side View> (8) Unit : mm 3-way valve at Gas side (Low Pressure) 2-way valve at Liquid side (High Pressure) 8

19 5.2.2 CU-UE8QKE Space necessary for installation <Top View> (24) (62.6) 32 00mm 00mm 000mm Anchor Bolt Pitch <Side View> <Front View> <Side View> (20) 62 Unit : mm 3-way valve at Gas side (Low Pressure) 2-way valve at Liquid side (High Pressure) 9

20 6. Refrigeration Cycle Diagram INDOOR OUTDOOR LIQUID SIDE EXPANSION * MUFFLER VALVE * STRAINER 2-WAY VALVE INTAKE AIR TEMP. SENSOR PIPE TEMP. SENSOR CONDENSER HEAT EXCHANGER (EVAPORATOR) GAS SIDE 3-WAY VALVE 4-WAYS VALVE MUFFLER COMPRESSOR COOLING HEATING * Not a standard replacement part. 20

21 7. Block Diagram 7. CS-YE9QKE CU-YE9QKE CS-YE2QKE CU-YE2QKE CS-UE9QKE CU-UE9QKE CS-UE2QKE CU-UE2QKE SINGLE PHASE POWER SUPPLY ø 230V 50Hz L N (INDOOR UNIT) (OUTDOOR UNIT) RY-AC PTC PTC RY-PWR FUSE04 RY-PWR FUSE0 FUSE30 FUSE02 RY-PWR2 SC U M U NTC TH3 SC TEMP. FUSE TEMP. FUSE 2 3 CT02 4-WAYS VALVE REACTOR FUSE03 IC9 MS 3 ~ MS 3 ~ NOISE FILTER 2

22 7.2 CS-UE8QKE CU-UE8QKE SINGLE PHASE POWER SUPPLY ø 230V 50Hz L N (INDOOR UNIT) (OUTDOOR UNIT) FUSE03 RY-PWR TH FUSE30 RY-PWR2 SC U M U TEMP. FUSE TEMP. FUSE 2 3 CT0 NTC FUSE04 RY-AC RY-PWR REACTOR SC 4-WAYS VALVE PTC PTC C03 FUSE0 IC9 MS 3 ~ MS 3 ~ NOISE FILTER 22

23 8. Wiring Connection Diagram 8. Indoor Unit 8.. CS-YE9QKE CS-YE2QKE CS-UE9QKE CS-UE2QKE TO OUTDOOR UNIT SINGLE PHASE POWER SUPPLY ø 230V 50Hz TEMP. FUSE 02 C (3A) TEMP. FUSE 02 C (3A) TERMINAL BOARD L N 2 3 GROUNDING TERMINAL Y/G GROUNDING TERMINAL Y/G EVAPORATOR M BR BL FAN MOTOR L P R W G RY-PWR AC304 (RED) AC303 (WHT) G30 (GRN) Y 7 B W BL 4 R CN-FM (WHT) ELECTRONIC CONTROLLER (MAIN) FUSE30 T3.5A L250V COMMUNICATION CIRCUIT RY-PWR2 NOISE FILTER CIRCUIT RECTIFICATION CIRCUIT CN-DISP (YLW) 6 CN-RMT (WHT) 4 CN-STM (WHT) 5 BR R O Y P 0 4 t CN-TH (RED) t0 5 M PIPING TEMP. SENSOR (THERMISTOR) SUCTION TEMP. SENSOR (THERMISTOR) UP DOWN LOUVER MOTOR REMARKS B : BLUE P: PINK BR: BROWN O: ORANGE BL: BLACK Y: YELLOW W: WHITE G: GREEN R: RED Y/G: YELLOW/GREEN 5 CN-DISP (WHT) ELECTRONIC CONTROLLER (DISPLAY & RECEIVER) W W W W W REMOTE CONTROLLER 23

24 8..2 CS-UE8QKE TO OUTDOOR UNIT SINGLE PHASE POWER SUPPLY ø 230V 50Hz TEMP. FUSE 02 C (3A) TEMP. FUSE 02 C (3A) TERMINAL BOARD L N 2 3 GROUNDING TERMINAL Y/G GROUNDING TERMINAL BR BL L P R W G RY-PWR AC304 (RED) AC303 (WHT) G30 (GRN) ELECTRONIC CONTROLLER (MAIN) FUSE30 T3.5A L250V COMMUNICATION CIRCUIT RY-PWR2 NOISE FILTER CIRCUIT CN-RMT (WHT) 4 CN-STM (WHT) 5 CN-STM2 (YLW) 5 BR R O Y P BR R O Y P 5 5 M M UP DOWN LOUVER MOTOR LEFT RIGHT LOUVER MOTOR Y/G EVAPORATOR M FAN MOTOR Y 7 B W BL 4 R CN-FM (WHT) RECTIFICATION CIRCUIT CN-DISP (YLW) t CN-TH (RED) t0 PIPING TEMP. SENSOR (THERMISTOR) SUCTION TEMP. SENSOR (THERMISTOR) REMARKS B : BLUE P: PINK BR: BROWN O: ORANGE BL: BLACK Y: YELLOW W: WHITE G: GREEN R: RED Y/G: YELLOW/GREEN 5 CN-DISP (WHT) ELECTRONIC CONTROLLER (DISPLAY & RECEIVER) W W W W W REMOTE CONTROLLER 24

25 8.2 Outdoor Unit 8.2. CU-YE9QKE CU-YE2QKE CU-UE9QKE CU-UE2QKE TO INDOOR UNIT BLK WHT 2 RED 3 DATA (RED) AC-BLK (BLK) TERMINAL BOARD FUSE04 (5A 250V) NOISE FILTER CIRCUIT GRY RAT2 (GRY) REACTOR GRY RAT (GRY) COMMUNICATION CIRCUIT CN-TH (WHT) 4 OUTDOOR AIR TEMP. SENSOR (THERMISTOR) 0 t 0 t PIPING TEMP. SENSOR (THERMISTOR) FAN MOTOR MS 3 ~ GRN GRN FUSE0 (20A 250V) AC-WHT (WHT) FG (GRN) FG2 (GRN) CN-MTR2 (WHT) CN-MTR (WHT) W U V IC FUSE02 T3.5A L250V PFC CIRCUIT ELECTRONIC CONTROLLER RECTIFICATION CIRCUIT RECTIFICATION CIRCUIT FUSE03 T3.5A L250V SWITCHING POWER SUPPLY CIRCUIT P N Q CN-TANK (WHT) 3 CN-HOT (WHT) 3 CN-STM (WHT) 6 U (RED) U V (BLU) V W (YLW) W 0 t COMP. TEMPERATURE SENSOR (THERMISTOR) YLW YLW ELECTRO-MAGNETIC COIL (4-WAYS VALVE) M RED BLU YLW ELECTRO-MAGNETIC COIL (EXPANSION VALVE) MS 3 ~ COMPRESSOR REMARKS BLACK: (BLK) WHITE: (WHT) YELLOW: (YLW) ORANGE: (ORG) BLUE: (BLU) RED: (RED) BROWN: (BRW) GREEN: (GRN) GRAY: (GRY) YELLOW/GREEN: (YLW/GRN) YELLOW (YLW) BLUE (BLU) RED (RED) TRADE MARK COMP. TERMINAL Resistance of Compressor Windings Resistance of Compressor Windings MODEL CU-YE9QKE/UE9QKE MODEL CU-YE2QKE/UE2QKE CONNECTION 5RS092XCD2 CONNECTION 5RS02XBC2 U-V.52 Ω U-V Ω U-W.52 Ω U-W Ω V-W.52 Ω V-W Ω Note: Resistance at 20 C of ambient temperature. Note: Resistance at 20 C of ambient temperature. 25

26 8.2.2 CU-UE8QKE TO INDOOR UNIT 2 RED 3 TERMINAL BOARD GRY RAT2 (GRY) REACTOR GRY RAT (GRY) BLK WHT DATA (RED) AC-BLK (BLK) NOISE FILTER CIRCUIT COMMUNICATION CIRCUIT CN-TH (WHT) 4 OUTDOOR AIR TEMP. SENSOR (THERMISTOR) 0 t 0 t PIPING TEMP. SENSOR (THERMISTOR) FUSE03 (20A 250V) AC-WHT (WHT) FUSE04 T3.5A L250V RECTIFICATION CIRCUIT CN-TANK (WHT) 3 0 t COMPRESSOR TEMP. SENSOR (THERMISTOR) FAN MOTOR MS 3 ~ GRN GRN FG (GRN) FG2 (GRN) CN-MTR2 (WHT) CN-MTR (WHT) W U V IC PFC CIRCUIT ELECTRONIC CONTROLLER RECTIFICATION CIRCUIT FUSE0 T3.5A L250V SWITCHING POWER SUPPLY CIRCUIT P N Q CN-HOT (WHT) 3 CN-STM (WHT) U V W 6 U (RED) V (BLU) W (YLW) ELECTRO-MAGNETIC COIL (4-WAYS VALVE) RED BLU YLW M ELECTRO-MAGNETIC COIL (EXPANSION VALVE) MS 3 ~ COMPRESSOR REMARKS BLACK: (BLK) WHITE: (WHT) YELLOW: (YLW) ORANGE: (ORG) BLUE: (BLU) RED: (RED) BROWN: (BRW) GREEN: (GRN) GRAY: (GRY) YELLOW/GREEN: (YLW/GRN) YELLOW (YLW) BLUE (BLU) RED (RED) TRADE MARK COMP. TERMINAL Resistance of Compressor Windings MODEL CU-UE8QKE CONNECTION 5RD32XBE2 U-V.897 Ω U-W.907 Ω V-W.882 Ω Note: Resistance at 20 C of ambient temperature. 26

27 9. Electronic Circuit Diagram 9. Indoor Unit 9.. CS-YE9QKE CS-YE2QKE CS-UE9QKE CS-UE2QKE TEMP. FUSE 02 C (3A) TEMP. FUSE 02 C (3A) TERMINAL BOARD 2 3 GROUNDING TERMINAL Y/G GROUNDING TERMINAL RY-PWR L L N BR BL R W G AC304 (RED) AC303 (WHT) G30 (GRN) FUSE30 T3.5A L250V ELECTRONIC CONTROLLER (MAIN) RY-PWR2 P SINGLE PHASE POWER SUPPLY ø 230V 50Hz Sensor (Thermistor) Characteristics Temperature (ºC) REMOTE CONTROLLER TO OUTDOOR UNIT COMMUNICATION CIRCUIT NOISE FILTER CIRCUIT Y/G EVAPORATOR RECTIFICATION CIRCUIT M Y 7 B W BL R FAN MOTOR CN-FM (WHT) 4 Resistance (kω) 0 0 IC GND-A 2 2 Pipe Temp. Sensor Intake Air Temp. Sensor IC03 2V VCC GND 44 R47 /2W 68 5% 43 R46 /2W 68 5% 5V 5V R62 5.0k C25 µ 6V R6 20.0k C27 µ 6V GND + 4 Vout Vcc GND GND 5 C20 47µ 6.3V 2 3 C µ 6V 5V_ ELECTRONIC CONTROLLER (DISPLAY & RECEIVER) POWER (green) LED20 TIMER (orange) LED R /0W 5% R202 2k /0W 5% PCB20 P.C.B 0 CN-DISP WHITE *CN-DISP YELLOW C3 0.µ 6V *R89 *R54 *R *C45 *C49 5V 2V CN-STM WHITE *CN-TH RED M UP DOWN LOUVER MOTOR SUCTION TEMP. SENSOR (THERMISTOR) PIPING TEMP. SENSOR (THERMISTOR) 0 t *CN-RMT 5V R85 5.k *C47 5V *C48 27

28 9..2 CS-UE8QKE TEMP. FUSE 02 C (3A) TEMP. FUSE 02 C (3A) TERMINAL BOARD 2 3 GROUNDING TERMINAL Y/G GROUNDING TERMINAL Y/G EVAPORATOR M Y 7 B W BL RY-PWR L L N BR BL W AC304 (RED) AC303 (WHT) G30 (GRN) 4 R FAN MOTOR CN-FM (WHT) R G FUSE30 T3.5A L250V ELECTRONIC CONTROLLER (MAIN) RY-PWR2 P SINGLE PHASE POWER SUPPLY ø 230V 50Hz Sensor (Thermistor) Characteristics Temperature (ºC) REMOTE CONTROLLER TO OUTDOOR UNIT COMMUNICATION CIRCUIT NOISE FILTER CIRCUIT RECTIFICATION CIRCUIT Resistance (kω) 0 0 IC GND-A 2 AUTO HEAT COOL DRY 2 MODE TIMER ON Pipe Temp. Sensor Intake Air Temp. Sensor OFF/ON TEMP FAN SPEED SET 2 3 FAN SPEED AIR SWING AIR SWING IC03 IC05 VCC VCC 2V V GND GND 44 R47 /2W 68 5% 43 R46 /2W 68 5% BZ0 BZ R30 k 5V 5V OFF CANCEL AC RC SET CHECK CLOCK RESET 5V 5V R62 5.0k C25 µ 6V R6 20.0k C27 µ 6V GND + 4 Vout Vcc GND GND 5 C20 47µ 6.3V 2 3 C µ 6V 5V_ ELECTRONIC CONTROLLER (DISPLAY & RECEIVER) POWER (green) LED20 TIMER (orange) LED R /0W 5% R202 2k /0W 5% PCB20 P.C.B 0 CN-DISP WHITE *CN-DISP YELLOW C3 0.µ 6V *R89 *R54 *R *C45 *C49 2V CN-STM WHITE *CN-TH RED M UP DOWN LOUVER MOTOR SUCTION TEMP. SENSOR (THERMISTOR) PIPING TEMP. SENSOR (THERMISTOR) t *CN-RMT 5V R85 5.k *C47 *C48 5V 2V *CN-STM2 M LEFT RIGHT LOUVER MOTOR 28

29 9.2 Outdoor Unit 9.2. CU-YE9QKE CU-YE2QKE CU-UE9QKE CU-UE2QKE TO INDOOR UNIT REACTOR BLK WHT FAN MOTOR MS 3 ~ 2 3 RED GRN GRN 3 5 DATA (RED) AC-BLK (BLK) FUSE0 (20A 250V) AC-WHT (WHT) FG (GRN) FG2 (GRN) CN-MTR2 (WHT) CN-MTR V 5 TERMINAL BOARD ELECTRONIC CONTROLLER + G5 R20 k C73 W U V G5 IC9 R k C75 0.0µ 50V GRY RAT2 (GRY) FUSE04 (5A 250V) NOISE FILTER CIRCUIT G5 R05 k C77 0.0µ 50V FUSE02 T3.5A L250V PFC CIRCUIT G5 C76 0.0µ 50V GRY RAT 3V (GRY) VCC IC GND G2 RECTIFICATION CIRCUIT IC7 3V VCC GND 8 G COMMUNICATION CIRCUIT RECTIFICATION CIRCUIT FUSE03 T3.5A L250V C89 0.µ 25V 3V G2 378 D D SWITCHING POWER SUPPLY CIRCUIT C6 µ 0V G8 P N D9 277 G2 Q 5V 327 D D R 5.8k % 54 U V W 5V CN-STM 3 C3 R µ 4.99k 0V % G8 G G8 R2 5.0k % C7 µ 0V G CN-TH WHITE CN-TANK WHITE 3 CN-HOT U (RED) V (BLU) W (YLW) M TANK TEMP. SENSOR (50kΩ 3950) RED BLU YLW EXPANSION VALVE OUTDOOR TEMP. SENSOR (5kΩ 3950) PIPE TEMP. SENSOR (4.96kΩ 3800) 4-WAYS VALVE MS 3 ~ COMPRESSOR Sensor (Thermistor) Characteristics Outdoor Air Sensor 2 Outdoor Heat Exchanger Sensor Compressor Temp. Sensor (Thermistor) Characteristics Resistance (kω) Resistance (kω) Temperature ( o C) Temperature ( o C) 29

30 9.2.2 CU-UE8QKE TO INDOOR UNIT BLK WHT FAN MOTOR MS 3 ~ 2 3 RED GRN GRN DATA (RED) AC-BLK (BLK) FUSE03 (20A 250V) AC-WHT (WHT) FG (GRN) FG2 (GRN) CN-MTR2 (WHT) CN-MTR (WHT) V 5 TERMINAL BOARD ELECTRONIC CONTROLLER + G2 *R33 k *C78 PFC CIRCUIT W U V G2 IC9 *R32 k *C86 0.0µ 50V GRY RAT2 (GRY) NOISE FILTER CIRCUIT G2 *R3 k *C88 0.0µ 50V REACTOR FUSE04 T3.5A L250V G2 *C87 0.0µ 50V RECTIFICATION CIRCUIT GRY RAT (GRY) 3V VCC IC GND G2 COMMUNICATION CIRCUIT FUSE0 T3.5A L250V 29 3V VCC RECTIFICATION 9 6 CIRCUIT *IC5 G2 SWITCHING POWER SUPPLY CIRCUIT 5V *R b *Q23 *D20 *C e c C9 µ 0V G2 G2 *D73 G2 *D CN-TANK C5 R µ 4.99k 0V % G2 G2 P N 5V Q 5V R 5.8k % V G2 R2 5.0k % + G2 *D74 *D76 C0 µ 0V *CN-STM *CN-HOT U (RED) U V (BLU) V W (YLW) W 0 3 t C88 220µ 0V CN-TH (WHT) M COMP. TEMP. SENSOR (50kΩ 3950) RED BLU YLW EXPANSION VALVE OUTDOOR AIR TEMP. SENSOR (5kΩ 3950) 0 2 t t 3 PIPING TEMP. SENSOR (4.96kΩ 3800) 4-WAYS VALVE MS 3 ~ COMPRESSOR Sensor (Thermistor) Characteristics Outdoor Air Sensor 2 Outdoor Heat Exchanger Sensor Compressor Temp. Sensor (Thermistor) Characteristics Resistance (kω) Resistance (kω) Temperature ( o C) Temperature ( o C) 30

31 0. Printed Circuit Board 0. Indoor Unit 0.. Main Printed Circuit Board AC304 AC303 G30 RY-PWR2 RY-PWR CN-FM CN-RMT CN-STM2 (UE8QKE only) CN-STM CN-DISP CN-TH JP (Random Auto Restart enable/disable) 3

32 0..2 Indicator & Receiver Printed Circuit Board CN-DISP 32

33 0.2 Outdoor Unit 0.2. Main Printed Circuit Board CU-YE9QKE CU-YE2QKE CU-UE9QKE CU-UE2QKE POWER TRANSISTOR (IPM) CN-HOT CN-STM CN-TH CURRENT TRANSFORMER (CT) CN-TANK CN-MTR CN-MTR2 AC-BLK DATA AC-WHT 33

34 CU-UE8QKE POWER TRANSISTOR (IPM) RAT RAT2 CURRENT TRANSFORMER (CT) CN-TANK CN-MTR CN-TH CN-STM CN-HOT FG2 DATA AC-WHT CN-MTR2 AC-BLK FG 34

35 0.2.2 CPU Printed Circuit Board CU-YE9QKE CU-YE2QKE CU-UE9QKE CU-UE2QKE 35

36 65 mm or more. Installation Instruction. Select the Best Location.. Indoor Unit Do not install the unit in excessive oil fume area such as kitchen, workshop and etc. There should not be any heat source or steam near the unit. There should not be any obstacles blocking the air circulation. A place where air circulation in the room is good. A place where drainage can be easily done. A place where noise prevention is taken into consideration. Do not install the unit near the door way. Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles. Recommended installation height for indoor unit shall be at least 2.5 m...2 Outdoor Unit If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from the condenser is not obstructed. There should not be any animal or plant which could be affected by hot air discharged. Keep the spaces indicated by arrows from wall, ceiling, fence or other obstacles. Do not place any obstacles which may cause a short circuit of the discharged air. If piping length is over the [piping length for additional gas], additional refrigerant should be added as shown in the table. Model Horse Power (HP) Piping size Gas RE9***,UE9***,YE9*** RE2***,UE2***,YE2***.0HP.5HP 9.52mm (3/8") RE5***.75HP 2.7mm UE8*** 2.0HP (/2") RE8*** RE24*** 2.5HP 5.88mm (5/8") Liquid 6.35mm (/4") Std. Length (m) 5 Max. Elevation (m) Min. Piping Length (m) Max. Piping Length (m) Additional Refrigerant (g/m) Piping Length for add. gas (m) Indoor/Outdoor Unit Installation Diagram Piping direction (Front side) Right Right Rear Right Left Left bottom Rear Left bottom 50 mm or more (Left and right are identical) Insulation of piping connections Carry out insulation after checking for gas leaks and secure with vinyl tape. Vinyl tape Attaching the remote control holder to the wall Remote control holder fixing screws 6 Remote control 3 It is advisable to avoid more than 2 blockage directions. For better ventilation & multiple-outdoor installation, please consult authorized dealer/specialist. Remote control holder 5 Attention not to bend up drain hose 00 mm or more 000 mm or more 00 mm or more 300 mm or more Installation parts you should purchase ( ) Installation plate Bushing-Sleeve ( ) Sleeve ( ) Putty ( ) (Gum Type Sealer) Bend the pipe as closely on the wall as possible, but be careful that it doesn t break. Power supply cord ( ) Vinyl tape (wide) ( ) Apply after carrying out a drainage test. To carry out the drainage test, remove the air filters and pour water into the heat exchanger. Saddle ( ) Connection cable ( ) Liquid side piping ( ) Gas side piping ( ) Additional drain hose ( ) This illustration is for explanation purposes only. The indoor unit will actually face a different way Example: For RE9*** If the unit is installed at 0 m distance, the quantity of additional refrigerant should be 50 g... (0-7.5) m 20 g/m = 50 g. 36

37 .2 Indoor Unit.2. How to Fix Installation Plate The mounting wall shall be strong and solid enough to prevent if from the vibration. Wall Wall More than More than More 2 screw than 2 Wall 28 mm DISTANCE TO PIPE HOLE CENTER 28 mm Measuring Tape 24.5 mm 28 mm PIPE HOLE CENTER DISTANCE TO PIPE HOLE CENTER 28 mm Installation plate For best strength of INDOOR unit installation, it is highly recommended to locate at 5 position as shown. PIPE HOLE CENTER 28 mm 24.5 mm Model RE9***,UE9***,YE9*** RE2***,UE2***,YE2*** RE5*** RE8***,UE8*** RE24*** Dimension 490 mm 82 mm 439 mm 432 mm 43 mm 95 mm 590 mm 82 mm 539 mm 532 mm 69 mm 29 mm The center of installation plate should be at more than at right and left of the wall. The distance from installation plate edge to ceiling should more than. From installation plate center to unit s left side is. From installation plate center to unit s right side is. B : For left side piping, piping connection for liquid should be about from this line. : For left side piping, piping connection for gas should be about from this line. Mount the installation plate on the wall with 5 screws or more (at least 5 screws). (If mounting the unit on the concrete wall, consider using anchor bolts.) o Always mount the installation plate horizontally by aligning the marking-off line with the thread and using a level gauge. 2 Drill the piping plate hole with ø70 mm hole-core drill. o Line according to the left and right side of the installation plate. The meeting point of the extended line is the center of the hole. Another method is by putting measuring tape at position as shown in the diagram above. The hole center is obtained by measuring the distance namely 28 mm for left and right hole respectively. o Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor side..2.2 To Drill a Hole in the Wall and Install a Sleeve of Piping Insert the piping sleeve to the hole. 2 Fix the bushing to the sleeve. 3 Cut the sleeve until it extrudes about 5 mm from the wall. Indoor Sleeve for tube assembly Wall Outdoor 5 mm CAUTION When the wall is hollow, please be sure to use the sleeve for tube assembly to prevent dangers caused by mice biting the connection cable. 4 Finish by sealing the sleeve with putty or caulking compound at the final stage. ø70 mm through hole Approx. 5-7 mm Bushing for tube assembly Putty or caulking compound 37

38 PUSH PUSH PUSH PUSH.2.3 Indoor Unit Installation Do not turn over the unit without it s shock absorber during pull out the piping. It may cause intake grille damage. Use shock absorber during pull out the piping to protect the intake grille from damage. pull out pull out the piping the piping Piping Piping Intake grille Shock absorber.2.3. For the right rear piping Step- Step-2 Step-3 Step-4 Pull out the Indoor piping Install the Indoor Unit Secure the Indoor Unit Insert the power supply cord and connection cable Insert the cables from bottom of the unit through the control board hole until terminal board area For the right and right bottom piping Step- Step-2 Pull out the Indoor piping Install the Indoor Unit Step-3 Insert the power supply cord and connection cable Insert the cables from bottom of the unit through the control board hole until terminal board area. Step-4 Secure the Indoor Unit For the embedded piping Step- Step-2 Step-3 Step-4 Step-5 Step-6 Step-7 Step-8 Replace the drain hose Bend the embedded piping Use a spring bender or equivalent to bend the piping so that the piping is not crushed. Pull the connection cable into Indoor Unit The power supply cord and indoor unit and outdoor unit connection cable can be connected without removing the front grille. Cut and flare the embedded piping When determining the dimensions of the piping, slide the unit all the way to the left on the installation plate. Refer to the section Cutting and flaring the piping. Install the Indoor Unit Connect the piping Please refer to Connecting the piping column in outdoor unit section. (Below steps are done after connecting the outdoor piping and gas-leakage confirmation.) Insulate and finish the piping Please refer to Insulation of piping connection column as mentioned in indoor/outdoor unit installation. Secure the Indoor Unit Right Rear piping Tape it with piping in a position as mentioned in Fig. below. Piping Drain hose How to keep the cover Cover for the right piping Cover for the bottom piping In case of the cover is cut, keep the cover at the rear of chassis as shown in the illustration for future reinstallation. (Left, right and 2 bottom covers for piping.) Right and Right Bottom piping Install the indoor unit Hook the indoor unit onto the upper portion of installation plate. (Engage the indoor unit with the upper edge of the installation plate). Ensure the hooks are properly seated on the installation plate by moving it in left and right. Secure the Indoor Unit marking Tape it with piping in a position as mentioned in Fig. below. Piping Drain hose Cover for the right piping. Press the lower left and right side of the unit against the installation plate until hooks engages with their slot (sound click). Insert the connection cable About mm Guide surface Cover Cover for the for the bottom piping left piping Cover for the bottom piping Indoor unit Unit s hook Cover for piping Cover for the left piping Hooks at installation plate Sleeve for piping hole Piping Drain hose Installation plate To take out the unit, push the marking at the bottom unit, and pull it slightly towards you to disengage the hooks from the unit. Connection cable Gas side piping Liquid side piping Connection cable Drain hose (This can be used for left rear piping and left bottom piping also.) 38

39 Replace the drain hose Rear view for left piping installation Drain cap Drain hose Drain hose Connection cable Adjust the piping slightly downwards. Piping Drain hose Connection cable More than 50 mm Sleeve for piping hole How to pull the piping and drain hose out, in case of the embedded piping. Apply putty or caulking material to seal the wall opening. PVC tube for drain hose (VP-20) PVC tube for drain hose More than 700 mm Indoor unit 72 mm More than 50 mm More than 470 mm Cable Piping Connection cable Piping Drain hose from main unit PVC tube (VP-65) for piping and connection cable PVC tube for drain hose (VP-30) In case of left piping how to insert the connection cable and drain hose. Drain hose 45 Cable Piping (For the right piping, follow the same procedure).2.4 Connect the Cable to the Indoor Unit The power supply cord, indoor and outdoor unit connection cable can be connected without removing the front grille. Install the indoor unit on the installing holder that mounted on the wall. 2 Open the front panel and grille door by loosening the screw. 3 Cable connection to the power supply through Isolating Devices (Disconnecting means). o Connect approved type polychloroprene sheathed power supply cord 3.5 mm 2 (.0 ~.75HP), mm 2 (2.0 ~ 2.5HP) type designation IEC 57 or heavier cord to the terminal board, and connect the others end of the cord to Isolating Devices (Disconnecting means). o Do not use joint power supply cord. Replace the wire if the existing wire (from concealed wiring, or o otherwise) is too short. In unavoidable case, joining of power supply cord between isolating devices and terminal board of air conditioner shall be done by using approved socket and plug with earth pin rated 5/6/20A. Wiring work to both socket and plug must follow to national wiring standard. 4 Bind all the power supply cord lead wire with tape and route the power supply cord via the left escapement. 5 Connection cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4.5 mm 2 (.0 ~.75HP) or mm 2 (2.0 ~ 2.5HP) flexible cord, type designation IEC 57 or heavier cord. Do not use joint connection cable. Replace the wire if the existing wire (from concealed wiring, or otherwise) is too short. Allowable connection cable length of each indoor unit shall be 30 m or less. 6 Bind all the indoor and outdoor connection cable with tape and route the connection cable via the right escapement. 39

40 7 Remove the tapes and connect the power supply cord and connection cable between indoor unit and outdoor unit according to the diagram below. Terminals on the outdoor unit 2 3 Colour of wires (connection cable) Terminals on the indoor unit (Power supply cord) Terminals on the isolating devices (Disconnecting means) L (L) N 2 3 (N) WARNING This equipment must be properly earthed. 8 Secure the power supply cord and connection cable onto the control board with the holder. 9 Close grille door by tighten with screw and close the front panel. Terminal Board Recommended length (mm) a b c d e Recommended length (mm) f g Control Board Earth wire longer than others AC wires for safety reason Holder Tape Holder Tape Power supply cord Power supply cord Indoor & outdoor connection cable Isolating Devices Outdoor unit Connection cable Note: Isolating Devices (Disconnecting means) should have minimum 3.0 mm contact gap. Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor s respectively. Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires as shown in the figure for the electrical safety in case of the slipping out of the cord from the anchorage. 40

41 WIRE STRIPPING, CONNECTING REQUIREMENT No loose strand when inserted 0 ± mm Wire stripping Indoor/outdoor connection terminal board 5 mm or more (gap between wires) Conductor fully inserted Conductor over inserted Conductor not fully inserted ACCEPT PROHIBITED PROHIBITED WARNING Do not joint wires RISK OF FIRE JOINING OF WIRES MAY CAUSE OVERHEATING AND FIRE. OR OR OR Use complete wire without joining. Use approved socket and plug with earth pin. Wire connection in this area must follow to national wiring rules. 4

42 .3 Outdoor Unit.3. Install the Outdoor Unit After selecting the best location, start installation according to Indoor/Outdoor Unit Installation Diagram. Fix the unit on concrete or rigid frame firmly and horizontally by bolt nut (ø0 mm). 2 When installing at roof, please consider strong wind and earthquake. Please fasten the installation stand firmly with bolt or nails. A B C D Model A B C D RE9***,UE9***,YE9*** UE2***,YE2*** 570 mm 05 mm 8.5 mm 320 mm RE2*** RE5*** 540 mm 60 mm 8.5 mm 330 mm UE8*** RE8*** RE24*** 63 mm 3 mm 6 mm mm.3.2 Connect the Piping.3.2. Connecting the Piping to Indoor Please make flare after inserting flare nut (locate at joint portion, of tube assembly) onto the copper pipe. (In case of using long piping) Connect the piping Align the center of piping and sufficiently tighten the flare nut with fingers. Further tighten the flare nut with torque wrench in specified torque as stated in the table. Do not overtighten, overtightening may cause gas leakage. Piping size Torque 6.35 mm (/4 ) [8 N m (.8 kgf.m)] 9.52 mm (3/8 ) [42 N m (4.3 kgf.m)] 2.7 mm (/2 ) [55 N m (5.6 kgf.m)] 5.88 mm (5/8 ) [65 N m (6.6 kgf.m)] 9.05 mm (3/4 ) [00 N m (0.2 kgf.m)] Connecting the Piping to Outdoor Decide piping length and then cut by using pipe cutter. Remove burrs from cut edge. Make flare after inserting the flare nut (located at valve) onto the copper pipe. Align center of piping to valves and then tighten with torque wrench to the specified torque as stated in the table. Spanner or Wrench Torque wrench 42

43 .3.3 Evacuation of the Equipment WHEN INSTALLING AN AIR CONDITIONER, BE SURE TO EVACUATE THE AIR INSIDE THE INDOOR UNIT AND PIPES in the following procedure. Indoor unit Liquid side Two-way valve Outdoor unit Close Gas side OPEN Three-way valve Close Lo Hi Vacuum pump CLOSE Connect a charging hose with a push pin to the Low side of a charging set and the service port of the 3-way valve. o Be sure to connect the end of the charging hose with the push pin to the service port. 2 Connect the center hose of the charging set to a vacuum pump. 3 Turn on the power switch of the vacuum pump and make sure that the needle in the gauge moves from 0 cmhg (0 MPa) to -76 cmhg (-0. MPa). Then evacuate the air approximately ten minutes. 4 Close the Low side valve of the charging set and turn off the vacuum pump. Make sure that the needle in the gauge does not move after approximately five minutes. Note: BE SURE TO TAKE THIS PROCEDURE IN ORDER TO AVOID REFRIGERENT GAS LEAKAGE. 5 Disconnect the charging hose from the vacuum pump and from the service port of the 3-way valve. 6 Tighten the service port caps of the 3-way valve at a torque of 8 N m with a torque wrench. 7 Remove the valve caps of both of the 2-way valve and 3-way valve. Position both of the valves to OPEN using a hexagonal wrench (4 mm). 8 Mount valve caps onto the 2-way valve and the 3-way valve. o Be sure to check for gas leakage.. If gauge needle does not move from 0 cmhg (0 MPa) to -76 cmhg (-0. MPa), in the step above take the following measure: - If the leak stops when the piping connections are tightened further, continue working from step. - If the leak does not stop when the connections are retightened, repair location of leak. - Do not release refrigerant during piping work for installation and reinstallation. - Take care of the liquid refrigerant, it may cause frostbite. 43

44 .3.4 Connect the Cable to the Outdoor Unit Remove the control board cover from the unit by loosening the screw. 2 Connection cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4.5 mm 2 (.0 ~.75HP) or mm 2 (2.0 ~ 2.5HP) flexible cord, type designation IEC 57 or heavier cord. Do not use joint connection cable. Replace the wire if the existing wire (from concealed wiring, or otherwise) is too short. Allowable connection cable length of each indoor unit shall be 30 m or less. Terminals on the outdoor unit Colour of wires Terminals on the indoor unit 3 Secure the cable onto the control board with the holder (clamper). 4 Attach the control board cover back to the original position with screw. 5 For wire stripping and connection requirement, refer to instruction.2.4 of indoor unit Holder Indoor and outdoor cable connection Indoor Unit Terminal Board WARNING Earth Wire longer than others AC wires for safety reason This equipment must be properly earthed. Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires for safety reason..3.5 Piping Insulation Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit Installation Diagram. Please wrap the insulated piping end to prevent water from going inside the piping. 2 If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by using POLY-E FOAM with thickness 6 mm or above Cutting and flaring the piping Please cut using pipe cutter and then remove the burrs. 2 Remove the burrs by using reamer. If burrs are not removed, gas leakage may be caused. Turn the piping end down to avoid the metal powder entering the pipe. 3 Please make flare after inserting the flare nut onto the copper pipes. Improper flaring Pipe Reamer Bar Handle Yoke Core Bar mm Inclined Surface Cracked Uneven damaged thickness. To cut Point down 2. To remove burrs Clamp handle Red arrow mark 3. To flare Copper pipe When properly flared, the internal surface of the flare will evenly shine and be of even thickness. Since the flare part comes into contact with the connections, carefully check the flare finish. 44

45 2. Operation Control 2. Basic Function Inverter control, which equipped with a microcomputer in determining the most suitable operating mode as time passes, automatically adjusts output power for maximum comfort always. In order to achieve the suitable operating mode, the microcomputer maintains the set temperature by measuring the temperature of the environment and performing temperature shifting. The compressor at outdoor unit is operating following the frequency instructed by the microcomputer at indoor unit that judging the condition according to internal setting temperature and intake air temperature. 2.. Internal Setting Temperature Once the operation starts, remote control setting temperature will be taken as base value for temperature shifting processes. These shifting processes are depending on the air conditioner settings and the operation environment. The final shifted value will be used as internal setting temperature and it is updated continuously whenever the electrical power is supplied to the unit Cooling Operation Thermostat control Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -.5 C continue for 3 minutes. When compressor is OFF (Thermostat OFF) and AUTO FAN is set, the fan will stop periodically. Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature > Compressor OFF point Soft Dry Operation Thermostat control Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -2.0 C continue for 3 minutes. When compressor is OFF (Thermostat OFF) and AUTO FAN is set, the fan will stop periodically. Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature > Compressor OFF point Heating Operation Thermostat control Compressor is OFF when Intake Air Temperature - Internal Setting Temperature > +2.0 C continue for 3 minutes. Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature < Compressor OFF point. 45

46 2..5 Automatic Operation This mode can be set using remote control and the operation is decided by remote control setting temperature, remote control operation mode and indoor intake air temperature. During operation mode judgment, indoor fan motor (with speed of Lo-) is running for 30 seconds to detect the indoor intake air temperature. Every 0 minutes, the indoor temperature is judged. For the st judgment o If indoor intake temperature - remote control setting temperature 2 C, COOL mode is decided. o If -2 C indoor intake temperature - remote control setting temperature < 2 C, DRY mode is decided. o If indoor intake temperature - remote control setting temperature < -2 C, HEAT mode is decided. For the 2nd judgment onwards o If indoor intake temperature - remote control setting temperature 3 C, if previous operate in DRY mode, then continue in DRY mode. otherwise COOL mode is decided. o If -2 C indoor intake temperature - remote control setting temperature < 3 C, maintain with previous mode o If indoor intake temperature - remote control setting temperature < -2 C, HEAT mode is decided. 2.2 Indoor Fan Motor Operation 2.2. Basic Rotation Speed (rpm) A. Basic Rotation Speed (rpm) i. Manual Fan Speed [Cooling, Dry] Fan motor s number of rotation is determined according to remote control setting. Remote control Tab Hi Me Me- Lo QLo CS-YE9QKE CS-YE2QKE CS-UE9QKE CS-UE2QKE Remote control Tab Hi Me+ Me Me- Lo CS-UE8QKE [Heating] Fan motor s number of rotation is determined according to remote control setting. Remote control Tab SHi Me Me- Lo QLo CS-YE9QKE CS-YE2QKE CS-UE9QKE CS-UE2QKE Remote control Tab SHi Me+ Me Me- Lo CS-UE8QKE 46

47 ii Auto Fan Speed [Cooling, Dry] According to room temperature and setting temperature, indoor fan speed is determined automatically. When set temperature is not achieved, the indoor fan will operate according to pattern below. When set temperature achieved, the indoor fan speed will be fixed. When thermostat off, the fan stop periodically. [Heating] According to indoor pipe temperature, automatic heating fan speed is determined as follows. B. Feedback control Immediately after the fan motor started, feedback control is performed once every second. During fan motor on, if fan motor feedback 2550 rpm or < 50 rpm continue for 0 seconds, then fan motor error counter increase, fan motor is then stop and restart. If the fan motor counter becomes 7 times, then H9 - fan motor error is detected. Operation stops and cannot on back. 2.3 Outdoor Fan Motor Operation Outdoor fan motor is operated with one fan speed only. It starts when compressor starts operation and it stops 30 seconds after compressor stops operation. 2.4 Airflow Direction There are two types of airflow, vertical airflow (directed by horizontal vane) and horizontal airflow (directed by vertical vanes). Control of airflow direction can be automatic (angles of direction is determined by operation mode, heat exchanger temperature and intake air temperature) and manual (angles of direction can be adjusted using remote control). 47

48 2.4. Vertical Airflow Operation Mode Vane Angle ( ) Cooling Auto Usual (Ventilation) 0 ~ 40 Control with dew 0 ~ 40 Manual Usual (Ventilation) Control with dew Dry Auto Usual 0 ~ 40 Control with dew 0 ~ 40 Manual Usual Control with dew Heating Manual Usual CS-YE9QKE CS-YE2QKE CS-UE9QKE CS-UE2QKE Cooling Dry Operation Mode Auto Manual Auto Manual Vane Angle ( ) Usual (Ventilation) 5 ~ 35 Control with dew 5 ~ 35 Usual (Ventilation) Control with dew Usual 5 ~ 35 Control with dew 5 ~ 35 Usual Control with dew Heating Manual Usual CS-UE8QKE Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the angles as stated above. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as Figure below. It does not swing during fan motor stop. When the air conditioner is stopped using remote control, the vane will shift to close position. 2 Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above and the positions of the vane are as Figure 2 below. When the air conditioner is stopped using remote control, the vane will shift to close position. 48

49 2.4.2 Horizontal Airflow (For UE8QKE only) Automatic horizontal airflow direction can be set using remote control; the vane swings left and right within the angles as stated below. It does not swing during fan motor stop. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as Figure below. Operation Mode Vane Angle ( ) A 68 ~ 5 Heating, with heat exchanger temperature B 90 Cooling and Soft Dry 68 ~ 5 2 Manual horizontal airflow direction can be set using remote control; the angles of the vane are as stated below and the positions of the vane are as Figure 2 above. Pattern Airflow Direction Patterns at Remote Control Vane Angle ( ) ON Timer Control ON timer can be set using remote control, the unit with timer set will start operate earlier than the setting time. This is to provide a comfortable environment when reaching the set ON time. 60 minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds to determine the indoor intake air temperature and outdoor air temperature in order to judge the operation starting time. From the above judgment, the decided operation will start operate earlier than the set time as shown below. 49

50 2.6 OFF Timer Control OFF timer can be set using remote control, the unit with timer set will stop operate at set time. 2.7 Auto Restart Control When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to four minutes (there are 0 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be selected randomly) after power supply resumes. This type of control is not applicable during ON/OFF Timer setting. This control can be omitted by open the circuit of JP at indoor unit printed circuit board. 2.8 Indication Panel LED POWER TIMER Color Green Orange Light ON Operation ON Timer Setting ON Light OFF Operation OFF Timer Setting OFF Note: If POWER LED is blinking, the possible operation of the unit are Hot Start, during Deice operation, operation mode judgment, or ON timer sampling. If Timer LED is blinking, there is an abnormality operation occurs. 50

51 3. Protection Control 3. Protection Control For All Operations 3.. Restart Control (Time Delay Safety Control) The Compressor will not turn on within 3 minutes from the moment operation stops, although the unit is turned on again by pressing OFF/ON button at remote control within this period. This control is not applicable if the power supply is cut off and on again. This phenomenon is to balance the pressure inside the refrigerant cycle Total Running Current When the outdoor unit total running current (AC) exceeds X value, the frequency instructed for compressor operation will be decreased. 2 If the running current does not exceed X value for 5 seconds, the frequency instructed will be increased. 3 However, if total outdoor unit running current exceeds Y value, compressor will be stopped immediately for 3 minutes. Model YE9QKE/UE9QKE YE2QKE/UE2QKE UE8QKE Operation Mode X (A) Y (A) X (A) Y (A) X (A) Y (A) Cooling / Soft Dry (A) Cooling / Soft Dry (B) Cooling / Soft Dry (C) Heating The first 30 minutes of cooling operation, (A) will be applied IPM (Power transistor) Prevention Control Overheating Prevention Control When the IPM temperature rises to 20 C, compressor operation will stop immediately. 2 Compressor operation restarts after 3 minutes the temperature decreases to 0 C. 3 If this condition repeats continuously 4 times within 20 minutes, timer LED will be blinking ( F96 is indicated). DC Peak Current Control When electric current to IPM exceeds set value of 6.0 ± 2.0A (YE,UE9/2QKE) and 20.2 ± 2.7A (UE8QKE), the compressor will stop operate. Then, operation will restart after 3 minutes. 2 If the set value is exceeded again more than 30 seconds after the compressor starts, the operation will restart after 3 minute. 3 If the set value exceeded again within 30 seconds after the compressor starts, the operation will restart after minute. If this condition repeats continuously for 7 times, all indoor and outdoor relays will be cut off, timer LED will be blinking ( F99 is indicated). 5

52 3..4 Compressor Overheating Prevention Control Instructed frequency for compressor operation will be regulated by compressor discharge temperature. The changes of frequency are as below. If compressor discharge temperature exceeds 03 C, compressor will be stopped, occurs 4 times per 20 minutes, timer LED will be blinking. ( F97 is indicated.) Frequency 03 C 99 C 96 C Comp temp OFF 8Hz/45s Down min A Hz max B Hz Free 88 C 87 C 86 C 3..5 Low Pressure Prevention Control (Gas Leakage Detection) Control start conditions o For 5 minutes, the compressor continuously operates and outdoor total current is between.22a and.38 A (YE,UE9/2QKE), between 0.75A and 0.95A (UE8QKE). o During Cooling and Soft Dry operations: Indoor suction temperature - indoor piping temperature is below 4 C. o During Heating operations : Indoor piping temperature - indoor suction is under 5 C. Control contents o Compressor stops (and restart after 3 minutes). o If the conditions above happen 2 times within 20 minutes, the unit will: Stop operation Timer LED blinks and F9 indicated Low Frequency Protection Control When the compressor operate at frequency lower than 24 Hz continued for 20 minutes, the operation frequency will be changed to 23 Hz for 2 minutes Low Frequency Protection Control 2 When all the below conditions comply, the compressor frequency will change to lower frequency. Temperature, T, for: Cooling/Soft Dry Heating Indoor intake air ( C) T < 4 or T 30 T < 4 or T 28 Outdoor air ( C) T < 3 or T 38 T < 4 or T 24 Indoor heat exchanger ( C) T < 30 T 0 52

53 3.2 Protection Control For Cooling & Soft Dry Operation 3.2. Outdoor Air Temperature Control The compressor operating frequency is regulated in accordance to the outdoor air temperature as shown in the diagram below. This control will begin minute after the compressor starts. Compressor frequency will adjust base on outdoor air temperature Cooling Overload Control Detects the Outdoor pipe temperature and carry out below restriction/limitation (Limit the compressor Operation frequency). The compressor stop if outdoor pipe temperature exceeds 6 C. If the compressor stops 4 times in 20 minutes, Timer LED blinking (F95 indicated: outdoor high pressure rise protection) Freeze Prevention Control When indoor heat exchanger temperature is lower than 0 C continuously for 6 minutes, compressor will stop operating. Compressor will resume its operation 3 minutes after the indoor heat exchanger is higher than 5 C. At the same time, indoor fan speed will be higher than during its normal operation. If indoor heat exchanger temperature is higher than 5 C for 5 minutes, the fan speed will return to its normal operation Freeze Prevention Control 2 Control start conditions o During Cooling operation and soft dry operation During thermo OFF condition, indoor intake temperature is less than 0 C or Compressor stops for freeze prevention control o Either one of the conditions above occurs 5 times in 60 minutes. Control contents o Operation stops o Timer LED blinks and H99 indicated Dew Prevention Control To prevent dew formation at indoor unit discharge area. This control will be activated if: o Outdoor air temperature and Indoor pipe temperature judgment by microcontroller is fulfilled. o When Cooling or Dry mode is operated more than 20 minutes or more. This control stopped if: o Compressor stopped. o Remote control setting changed (fan speed / temperature). o Outdoor air temperature and indoor intake temperature changed. Fan speed will be adjusted accordingly in this control. 53

54 3.2.6 Odor Cut Control To reduce the odor released from the unit. o Start Condition AUTO FAN Speed is selected during COOL or DRY operation. During freeze prevention control and timer preliminary operation, this control is not applicable. o Control content Depends on compressor conditions:. Compressor OFF Compressor ON. The indoor unit fan stops temporarily and then starts to blow at minimum airflow for 30 seconds. 2. Compressor ON Compressor OFF. The indoor unit fan stops for 90 seconds and then blows at minimum airflow for 20 seconds. 3.3 Protection Control For Heating Operation 3.3. Intake Air Temperature Control Compressor will operate at limited freq., if indoor intake air temperature is 30 C or above Outdoor Air Temperature Control The Max current value is regulated when the outdoor air temperature rise above 4 C in order to avoid compressor overloading Overload Protection Control The compressor operating frequency is regulated in accordance to indoor heat exchanger temperature as shown below. If the heat exchanger temperature exceeds 60 C, compressor will stop Low Temperature Compressor Oil Return Control In heating operation, if the outdoor temperature falls below -0 C when compressor starts, the compressor frequency will be regulated up to 600 seconds Cold Draught Prevention Control When indoor pipe temperature is low, cold draught operation starts where indoor fan speed will be reduced Deice Operation When outdoor pipe temperature and outdoor air temperature is low, deice operation start where indoor fan motor and outdoor fan motor stop and operation LED blinks. 54

55 4. Servicing Mode 4. Auto OFF/ON Button AUTO OPERATION MODE The Auto operation will be activated immediately once the Auto OFF/ON button is pressed. This operation can be used to operate air conditioner with limited function if remote control is misplaced or malfunction. 2 TEST RUN OPERATION (FOR PUMP DOWN/SERVICING PURPOSE) The Test Run operation will be activated if the Auto OFF/ON button is pressed continuously for more than 5 seconds. A beep sound will heard at the fifth seconds, in order to identify the starting of Test Run operation (Forced cooling operation). Within 5 minutes after Forced cooling operation start, the Auto OFF/ON button is pressed for more than 5 seconds. A 2 beep sounds will heard at the fifth seconds, in order to identify the starting of Forced heating operation. The Auto OFF/ON button may be used together with remote control to set / change the advance setting of air conditioner operation. 3 REMOTE CONTROL NUMBER SWITCH MODE The Remote Control Number Switch Mode will be activated if the Auto OFF/ON button is pressed continuously for more than seconds (3 beep sounds will occur at th seconds to identify the Remote Control Number Switch Mode is in standby condition) and press AC RESET button and then press any button at remote control to transmit and store the desired transmission code to the EEPROM. There are 4 types of remote control transmission code could be selected and stored in EEPROM of indoor unit. The indoor unit will only operate when received signal with same transmission code from remote control. This could prevent signal interference when there are 2 or more indoor units installed nearby together. To change remote control transmission code, short or open jumpers at the remote control printed circuit board. (YE9QKE) Remote Control Printed Circuit Board Jumper A (J-A) Jumper B (J-B) Remote Control No. Short Open A (Default) Open (cut jumper) Open B Short Short C Open (cut jumper) Short D 55

56 (YE2QKE, UE9QKE, UE2QKE, UE8QKE) J D Remote Control Printed Circuit Board Jumper A (J) Jumper B (D) Remote Control No. Short Open A (Default) Open Open B Short *Short with diode C Open *Short with diode D During Remote Control Number Switch Mode, press any button at remote control to transmit and store the transmission code to the EEPROM. 4 REMOTE CONTROL RECEIVING SOUND OFF/ON MODE The Remote Control Receiving Sound OFF/ON Mode will be activated if the Auto OFF/ON button is pressed continuously for more than 6 seconds (4 beep sounds will occur at 6th seconds to identify the Remote Control Receiving Sound Off/On Mode is in standby condition) and press AC Reset button at remote control. Press Auto OFF/ON button to toggle remote control receiving sound. o Short beep : Turn OFF remote control receiving sound. o Long beep : Turn ON remote control receiving sound. After Auto OFF/ON Button is pressed, the 20 seconds counter for Remote Control Receiving Sound OFF/ON Mode is restarted. 4.2 Remote Control Button 4.2. SET Button To check remote control transmission code and store the transmission code to EEPROM: o Press Set button continuously for 0 seconds by using pointer. o Press Timer Set button until a beep sound is heard as confirmation of transmission code changed RESET (RC) To clear and restore the remote control setting to factory default. o Press once to clear the memory RESET (AC) To restore the unit s setting to factory default. o Press once to restore the unit s setting. o TIMER To change indoor unit indicator s LED intensity. o Press continuously for 5 seconds TIMER To change remote control display from Degree Celsius ( C) to Degree Fahrenheit ( F). o Press continuously for 0 seconds. 56

57 5. Troubleshooting Guide 5. Refrigeration Cycle System In order to diagnose malfunctions, make sure that there are no electrical problems before inspecting the refrigeration cycle. Such problems include insufficient insulation, problem with the power source, malfunction of a compressor and a fan. The normal outlet air temperature and pressure of the refrigeration cycle depends on various conditions, the standard values for them are shown in the table on the right. 57

58 5.2 Relationship Between The Condition Of The Air Conditioner And Pressure And Electric Current Condition of the Cooling Mode air conditioner Low Pressure High Pressure Insufficient refrigerant (gas leakage) Clogged capillary tube or Strainer Electric current during operation Low Pressure Heating Mode High Pressure Electric current during operation Short circuit in the indoor unit Heat radiation deficiency of the outdoor unit Inefficient compression Carry out the measurements of pressure, electric current, and temperature fifteen minutes after an operation is started. 58

59 5.3 Breakdown Self Diagnosis Function 5.3. Self Diagnosis Function (Three Digits Alphanumeric Code) Once abnormality has occurred during operation, the unit will stop its operation, and Timer LEDs blink. Although Timer LED goes off when power supply is turned off, if the unit is operated under a breakdown condition, the LED will light up again. In operation after breakdown repair, the Timer LED will no more blink. The last error code (abnormality) will be stored in IC memory To Make a Diagnosis Timer LED start to blink and the unit automatically stops the operation. 2 Press the CHECK button on the remote controller continuously for 5 seconds will be displayed on the remote controller display. Note: Display only for - -. (No transmitting signal, no receiving sound and no Power LED blinking.) 4 Press the TIMER or button on the remote controller. The code H00 (no abnormality) will be displayed and signal will be transmitted to the main unit. 5 Every press of the button (up or down) will increase abnormality numbers and transmit abnormality code signal to the main unit. 6 When the latest abnormality code on the main unit and code transmitted from the remote controller are matched, power LED will light up for 30 seconds and a beep sound (continuously for 4 seconds) will be heard. If no codes are matched, power LED will light up for 0.5 seconds and no sound will be heard. 7 The breakdown diagnosis mode will be canceled by pressing the CHECK button continuously for 5 seconds or without any operation the remote control for 30 seconds. 8 The LED will be off if the unit is turned off or the RESET button on the main unit is pressed To Display Memorized Error Code (Protective Operation) status: Turn power on. 2 Press the CHECK button on the remote controller continuously for 5 seconds will be displayed on the remote controller display. Note: Display only for - -. (No transmitting signal, no receiving sound and no Power LED blinking.) 4 Press the TIMER or button on the remote controller. The code H00 (no abnormality) will be displayed and signal will be transmitted to the main unit. The power LED lights up. If no abnormality is stored in the memory, three beeps sound will be heard. 5 Every press of the button (up or down) will increase abnormality numbers and transmit abnormality code signal to the main unit When the latest abnormality code on the main unit and code transmitted from the remote controller are matched, power LED will light up for 30 seconds and a beep sound (continuously for 4 seconds) will be heard. If no codes are matched, power LED will light up for 0.5 seconds and no sound will be heard. 7 The breakdown diagnosis mode will be canceled unless pressing the CHECK button continuously for 5 seconds or operating the unit for 30 seconds. 8 The same diagnosis can be repeated by turning power on again To Clear Memorized Error (Protective Operation) Status after Repair: Turn power on (in standby condition). 2 Press the AUTO button for 5 seconds (A beep receiving sound) on the main unit to operate the unit at Forced Cooling Operation mode. 3 Press the CHECK button on the remote controller for about second with a pointed object to transmit signal to main unit. A beep sound is heard from main unit and the data is cleared Temporary Operation (Depending On Breakdown Status) Press the AUTO button (A beep receiving sound) on the main unit to operate the unit. (Remote control will become possible.) 2 The unit can temporarily be used until repaired. Error Code Operation Temporary items H23 Cooling Emergency H27, H28 Cooling, Heating Operation with H26 Cooling, Heating limited power

60 5.4 Error Codes Table Diagnosis display Abnormality / Protection control Abnormality Judgment Protection Operation Problem Check location H00 No memory of failure Normal operation H H2 H4 H5 H6 H9 H23 H24 H25 H27 H28 H30 H32 H33 H34 H36 H37 H38 H39 Indoor/outdoor abnormal communication Indoor unit capacity unmatched Indoor intake air temperature sensor abnormality Compressor temperature sensor abnormality Outdoor current transformer (CT) abnormality Indoor fan motor merchanism lock Indoor heat exchanger temperature sensor abnormality Indoor heat exchanger temperature sensor 2 abnormality Indoor ion device abnormality Outdoor air temperature sensor abnormality Outdoor heat exchanger temperature sensor abnormality Outdoor discharge pipe temperature sensor abnormality Outdoor heat exchanger temperature sensor 2 abnormality Indoor / outdoor misconnection abnormality Outdoor heat sink temperature sensor abnormality Outdoor gas pipe temperature sensor abnormality Outdoor liquid pipe temperature sensor abnormality Indoor/Outdoor mismatch (brand code) Abnormal indoor operating unit or standby units After operation for minute 90s after power supply Indoor fan only operation can start by entering into force cooling operation Continuous for 5s Continuous for 5s Continuous happen for 7 times Continuous for 5s Continuous for 5s Port is ON for 0s during ion device off Continuous for 5s Continuous for 5s Continuous for 5s Continuous for 5s Continuous for 2s Continuous for 5s Continuous for 5s 3 times happen within 40 minutes Indoor/outdoor communication not establish Total indoor capability more than maximum limit or less than minimum limit, or number of indoor unit less than two Indoor intake air temperature sensor open or short circuit Compressor temperature sensor open or short circuit Current transformer faulty or compressor faulty Indoor fan motor lock or feedback abnormal Indoor heat exchanger temperature sensor open or short circuit Indoor heat exchanger temperature sensor 2 open or short circuit Indoor/outdoor wire terminal Indoor/outdoor PCB Indoor/outdoor connection wire Indoor/outdoor connection wire Indoor/outdoor PCB Specification and combination table in catalogue Indoor intake air temperature sensor lead wire and connector Compressor temperature sensor lead wire and connector Outdoor PCB faulty or compressor faulty Fan motor lead wire and connector Fan motor lock or block Indoor heat exchanger temperature sensor lead wire and connector Indoor heat exchanger temperature sensor 2 lead wire and connector ion device PCB Heating protection operation only Cooling protection operation only Outdoor air temperature sensor open or short circuit Outdoor heat exchanger temperature sensor open or short circuit Outdoor discharge pipe temperature sensor open or short circuit Outdoor heat exchanger temperature sensor 2 open or short circuit Indoor and outdoor rated voltage different Outdoor heat sink temperature sensor open or short circuit Outdoor gas pipe temperature sensor open or short circuit Outdoor liquid pipe temperature sensor open or short circuit Brand code not match Wrong wiring and connecting pipe, expansion valve abnormality, indoor heat exchanger sensor open circuit Outdoor air temperature sensor lead wire and connector Outdoor heat exchanger temperature sensor lead wire and connector Outdoor discharge pipe temperature sensor lead wire and connector Outdoor heat exchanger temperature sensor 2 lead wire and connector Indoor and outdoor units check Outdoor heat sink sensor Outdoor gas pipe temperature sensor lead wire and connector Outdoor liquid pipe temperature sensor lead wire and connector Check indoor unit and outdoor unit Check indoor/outdoor connection wire and connection pipe Indoor heat exchanger sensor lead wire and connector Expansion valve and lead wire and connector 60

61 Diagnosis display H4 H59 H64 H70 H97 H98 H99 F F7 F90 F9 F93 F94 F95 F96 F97 F98 F99 Abnormality / Protection control Abnormal wiring or piping connection ECONAVI sensor abnormality Outdoor high pressure sensor abnormality Light sensor abnormality Outdoor fan motor mechanism lock Indoor high pressure protection Indoor operating unit freeze protection 4-way valve switching abnormality Indoor standby units freezing abnormality Power factor correction (PFC) circuit protection Refrigeration cycle abnormality Compressor abnormal revolution Compressor discharge overshoot protection Outdoor cooling high pressure protection Power transistor module overheating protection Compressor overheating protection Total running current protection Outdoor direct current (DC) peak detection Abnormality Judgment Protection Operation Continuous for 25s Continuous for minutes Continuous for 24 hours, 5days 2 times happen within 30 minutes 4 times happen within 30 minutes 3 times happen within 40 minutes 4 times happen within 0 minutes 2 times happen within 20 minutes 4 times happen within 20 minutes 4 times happen within 30 minutes 4 times happen within 20 minutes 4 times happen within 30 minutes 3 times happen within 30 minutes 3 times happen within 20 minutes Continuous happen for 7 times Problem Wrong wiring and connecting pipe, expansion valve abnormality ECONAVI sensor open or short circuit High pressure sensor open circuit during compressor stop Light sensor open or short circuit Outdoor fan motor lock or feedback abnormal Indoor high pressure protection (Heating) Indoor freeze protection (Cooling) 4-way valve switching abnormal Wrong wiring and connecting pipe, expansion valve leakage, indoor heat exchanger sensor open circuit Power factor correction circuit abnormal Refrigeration cycle abnormal Compressor abnormal revolution Compressor discharge pressure overshoot Cooling high pressure protection Power transistor module overheat Check location Check indoor/outdoor connection wire and connection pipe Expansion valve and lead wire and connector ECONAVI sensor (defective or disconnected) ECONAVI PCB High pressure sensor Lead wire and connector Light sensor (defective or disconnected) Outdoor fan motor lead wire and connector Fan motor lock or block Check indoor heat exchanger Air filter dirty Air circulation short circuit Check indoor heat exchanger Air filter dirty Air circulation short circuit 4-way valve Lead wire and connector Check indoor/outdoor connection wire and pipe Indoor heat exchanger sensor lead wire and connector Expansion valve lead wire and connector Outdoor PCB faulty Insufficient refrigerant or valve close Power transistor module faulty or compressor lock Check refrigeration system Check refrigeration system Outdoor air circuit PCB faulty Outdoor air circuit (fan motor) Compressor overheat Insufficient refrigerant Total current protection Power transistor module current protection Check refrigeration system Power source or compressor lock Power transistor module faulty or compressor lock 6

62 5.5 Self-diagnosis Method 5.5. H (Indoor/Outdoor Abnormal Communication) Malfunction Decision Conditions During startup and operation of cooling and heating, the data received from outdoor unit in indoor unit signal transmission is checked whether it is normal. Malfunction Caused Faulty indoor unit PCB. Faulty outdoor unit PCB. Indoor unit-outdoor unit signal transmission error due to wiring error. Indoor unit-outdoor unit signal transmission error due to breaking of wire in the connection wires between the indoor and outdoor units. Troubleshooting 62

63 5.5.2 H2 (Indoor/Outdoor Capacity Rank Mismatched) Malfunction Decision Conditions During startup, error code appears when different types of indoor and outdoor units are interconnected. Malfunction Caused Wrong models interconnected. Wrong indoor unit or outdoor unit PCBs mounted. Indoor unit or outdoor unit PCBs defective. Indoor-outdoor unit signal transmission error due to wrong wiring. Indoor-outdoor unit signal transmission error due to breaking of wire 3 in the connection wires between the indoor and outdoor units. Troubleshooting 63

64 5.5.3 H4 (Indoor Intake Air Temperature Sensor Abnormality) Malfunction Decision Conditions During startup and operation of cooling and heating, the temperatures detected by the indoor intake air temperature sensor are used to determine sensor errors. Malfunction Caused Faulty connector connection. Faulty sensor. Faulty PCB. Troubleshooting 64

65 5.5.4 H5 (Compressor Temperature Sensor Abnormality) Malfunction Decision Conditions During startup and operation of cooling and heating, the temperatures detected by the outdoor compressor temperature sensor are used to determine sensor errors. Malfunction Caused Faulty connector connection. Faulty sensor. Faulty PCB. Troubleshooting 65

66 5.5.5 H6 (Outdoor Current Transformer) Malfunction Decision Conditions An input current, detected by Current Transformer CT, is below threshold value when the compressor is operating at certain frequency value for 3 minutes. Malfunction Caused Lack of gas Broken CT (current transformer) Broken Outdoor PCB Troubleshooting 66

67 5.5.6 H9 (Indoor Fan Motor DC Motor Mechanism Locked) Malfunction Decision Conditions The rotation speed detected by the Hall IC during fan motor operation is used to determine abnormal fan motor (feedback of rotation > 2550rpm or < 50rpm). Malfunction Caused Operation stops due to short circuit inside the fan motor winding. Operation stops due to breaking of wire inside the fan motor. Operation stops due to breaking of fan motor lead wires. Operation stops due to Hall IC malfunction. Operation error due to faulty indoor unit PCB. Troubleshooting 67

68 5.5.7 H23 (Indoor Pipe Temperature Sensor Abnormality) Malfunction Decision Conditions During startup and operation of cooling and heating, the temperatures detected by the indoor heat exchanger temperature sensor are used to determine sensor errors. Malfunction Caused Faulty connector connection. Faulty sensor. Faulty PCB. Troubleshooting 68

69 5.5.8 H27 (Outdoor Air Temperature Sensor Abnormality) Malfunction Decision Conditions During startup and operation of cooling and heating, the temperatures detected by the outdoor air temperature sensor are used to determine sensor errors. Malfunction Caused Faulty connector connection. Faulty sensor. Faulty PCB. Troubleshooting 69

70 5.5.9 H28 (Outdoor Pipe Temperature Sensor Abnormality) Malfunction Decision Conditions During startup and operation of cooling and heating, the temperatures detected by the outdoor pipe temperature sensor are used to determine sensor errors. Malfunction Caused Faulty connector connection. Faulty sensor. Faulty PCB. Troubleshooting 70

71 5.5.0 H30 (Compressor Discharge Temperature Sensor Abnormality) Malfunction Decision Conditions During startup and operation of cooling and heating, the temperatures detected by the outdoor discharge pipe temperature sensor are used to determine sensor errors. Malfunction Caused Faulty connector connection. Faulty sensor. Faulty PCB. Troubleshooting 7

72 5.5. H32 (Outdoor Heat Exchanger Temperature Sensor 2 Abnormality) Malfunction Decision Conditions During startup and operation of cooling and heating, the temperatures detected by the outdoor heat exchanger temperature sensor are used to determine sensor errors. Malfunction Caused Faulty connector connection. Faulty sensor. Faulty PCB. Troubleshooting 72

73 5.5.2 H33 (Unspecified Voltage between Indoor and Outdoor) Malfunction Decision Conditions The supply power is detected for its requirement by the indoor/outdoor transmission. Malfunction Caused Wrong models interconnected. Wrong indoor unit and outdoor unit PCBs used. Indoor unit or outdoor unit PCB defective. Troubleshooting 73

74 5.5.3 H34 (Outdoor Heat Sink Temperature Sensor Abnormality) Malfunction Decision Conditions During startup and operation of cooling and heating, the temperatures detected by the outdoor heat sink temperature sensor are used to determine sensor errors. Malfunction Caused Faulty connector connection. Faulty sensor. Faulty PCB. Troubleshooting 74

75 5.5.4 H36 (Outdoor Gas Pipe Sensor Abnormality) Malfunction Decision Conditions During startup and operation of cooling and heating, the temperatures detected by the outdoor gas pipe temperature sensor are used to determine sensor errors. Malfunction Caused Faulty connector connection. Faulty sensor. Faulty PCB. Troubleshooting 75

76 5.5.5 H37 (Outdoor Liquid Pipe Temperature Sensor Abnormality) Malfunction Decision Conditions During startup and operation of cooling and heating, the temperatures detected by the outdoor liquid pipe temperature sensor are used to determine sensor errors. Malfunction Caused Faulty connector connection. Faulty sensor. Faulty PCB. Troubleshooting 76

77 5.5.6 H98 (Error Code Stored in Memory and no alarm is triggered / no TIMER LED flashing) Malfunction Decision Conditions Indoor high pressure is detected when indoor heat exchanger is detecting very high temperature when the unit is operating in heating operation. Phenomena: unit is stopping and re-starting very often in heating mode Malfunction Caused Indoor heat exchanger thermistor Clogged air filter or heat exchanger Over-bent pipe (liquid side) Troubleshooting 77

78 5.5.7 H99 (Indoor Freeze Prevention Protection: Cooling or Soft Dry) Error Code will not display (no Timer LED blinking) but store in EEPROM Malfunction Decision Conditions Freeze prevention control takes place (when indoor pipe temperature is lower than 2 C) Malfunction Caused Air short circuit at indoor unit Clogged indoor unit air filter Dust accumulation on the indoor unit heat exchanger 2/3 way valve closed Faulty indoor unit fan motor Refrigerant shortage (refrigerant leakage) Clogged expansion valve or strainer Faulty indoor pipe temperature sensor Faulty indoor unit PCB Troubleshooting 78

79 5.5.8 F (4-way valve Abnormality) Malfunction Decision Conditions When indoor heat exchanger is cold during heating (except deice) or when indoor heat exchanger is hot during cooling and compressor operating, the 4-way valve is detected as malfunction. Malfunction Caused Indoor heat exchanger (pipe) thermistor 4-way valve malfunction Troubleshooting * Check gas side pipe for hot gas flow in cooling mode 79

80 5.5.9 F7 (Indoor Standby Units Freezing Abnormality) Malfunction Decision Conditions When the different between indoor intake air temperature and indoor pipe temperature is above 0 C or indoor pipe temperature is below -.0 C. Remark: When the indoor standby unit is freezing, the outdoor unit transfers F7 error code to the corresponding indoor unit and H39 to other indoor unit(s). Malfunction Caused Wrong wiring connection Faulty sensor Faulty expansion valve Troubleshooting 80

81 F90 (Power Factor Correction Protection) Malfunction Decision Conditions To maintain DC voltage level supply to power transistor. To detect high DC voltage level after rectification. Malfunction Caused During startup and operation of cooling and heating, when Power Factor Correction (PFC) protection circuitry at the outdoor unit main PCB senses abnormal DC voltage level for power transistors. When DC voltage detected is LOW, transistor switching will turn ON by controller to push-up the DC level. When DC voltage detected is HIGH (39Vdc 425Vdc), active LOW signal will send by the controller to turn OFF relay RY-C. Troubleshooting 8

82 5.5.2 F9 (Refrigeration Cycle Abnormality) Malfunction Decision Conditions The input current is low while the compressor is running at higher than the setting frequency. Malfunction Caused Lack of gas. 3-way valve close. Troubleshooting 82

83 F93 (Compressor Rotation Failure) Malfunction Decision Conditions A compressor rotation failure is detected by checking the compressor running condition through the position detection circuit. Malfunction Caused Compressor terminal disconnect Faulty Outdoor PCB Faulty compressor Troubleshooting 83

84 F95 (Outdoor High Pressure Protection: Cooling or Soft Dry) Malfunction Decision Conditions During operation of cooling or soft dry, when outdoor unit heat exchanger high temperature data is detected by the outdoor unit heat exchanger thermistor. Malfunction Caused Outdoor heat exchanger temperature rise due to short-circuit of hot discharge air flow. Outdoor heat exchanger temperature rise due to defective of outdoor fan motor. Outdoor heat exchange temperature rise due to defective outdoor heat exchanger thermistor. Outdoor heat exchanger temperature rise due to defective of outdoor unit PCB. Troubleshooting 84

85 F96 (IPM Overheating) Malfunction Decision Conditions During operating of cooling and heating, when IPM temperature data (20 C) is detected by the IPM temperature sensor. Multi Models Only o Compressor Overheating: During operation of cooling and heating, when the compressor OL is activated. o Heat Sink Overheating: During operation of cooling and heating, when heat sink temperature data (90 C) is detected by the heat sink temperature sensor. Malfunction Caused IPM overheats due to short circuit of hot discharge air flow. IPM overheats due to defective of outdoor fan motor. IPM overheats due to defective of internal circuitry of IPM. IPM overheats due to defective IPM temperature sensor. Multi Models Only Compressor OL connector poor contact. Compressor OL faulty. Troubleshooting 85

86 F97 (Compressor Overheating) Malfunction Decision Conditions During operation of cooling and heating, when compressor tank temperature data (03 C) is detected by the compressor tank temperature sensor. Malfunction Caused Faulty compressor tank temperature sensor 2/3 way valve closed Refrigerant shortage (refrigerant leakage) Faulty outdoor unit PCB Faulty compressor Troubleshooting 86

87 F98 (Input Over Current Detection) Malfunction Decision Conditions During operation of cooling and heating, when an input over-current (X value in Total Running Current Control) is detected by checking the input current value being detected by current transformer (CT) with the compressor running. Malfunction Caused Excessive refrigerant. Faulty outdoor unit PCB. Troubleshooting 87

88 F99 (DC Peak Detection) Malfunction Decision Conditions During startup and operation of cooling and heating, when inverter DC peak data is received by the outdoor internal DC Peak sensing circuitry. Malfunction Caused DC current peak due to compressor failure. DC current peak due to defective power transistor(s). DC current peak due to defective outdoor unit PCB. DC current peak due to short circuit. Troubleshooting 88

89 6. Disassembly and Assembly Instructions WARNING High Voltage are generated in the electrical parts area by the capacitor. Ensure that the capacitor has discharged sufficiently before proceeding with repair work. Failure to heed this caution may result in electric shocks. 6. Indoor Electronic Controllers, Cross Flow Fan and Indoor Fan Motor Removal Procedures 6.. CS-YE9QKE CS-YE2QKE CS-UE9QKE CS-UE2QKE 6... To remove front grille 3. Hold both sides of the front grille and remove it by pulling up and toward yourself gently. 2. Remove 2 caps and 2 screws at the bottom of discharge vane.. Lift to open the horizontal vane gently. Figure To remove horizontal vane Figure 2 89

90 6...3 To remove power electronic controller AC304 AC303 G30 RY-PWR2 RY-PWR CN-FM CN-RMT CN-STM CN-DISP CN-TH Figure Figure 4 To remove discharge grille 0. Pull out to remove the drain hose from the discharge grille. Then pull the discharge grille downward gently to dismantle it Figure 5 90

91 6...5 To remove control board 2. Remove 4 screws holding the control board then pull out the control board. Figure To remove cross flow fan and indoor fan motor 3. Remove the screw that holding the cross flow fan and fan motor axis. Figure Figure 8 9

92 6. Push the holdfast to the left and lift up the evaporator. Evaporator 7. Remove the cross flow fan from the unit by pulling it to the left and downward. Figure 9 8. Fan motor can be removed after the removal of cross flow fan. Reminder: To reinstall the fan motor, adjust the fan motor connector to 45 towards you before fixing control board. Figure 0 Reminder: To reinstall the cross flow fan, ensure cross flow fan is in line as shown in figure 0 92

93 WARNING High Voltage are generated in the electrical parts area by the capacitor. Ensure that the capacitor has discharged sufficiently before proceeding with repair work. Failure to heed this caution may result in electric shocks. 6.2 Indoor Electronic Controllers, Cross Flow Fan and Indoor Fan Motor Removal Procedures 6.2. CS-UE8QKE To remove front grille To remove horizontal vane Figure Figure 2 93

94 To remove power electronic controller AC304 AC303 G30 RY-PWR2 RY-PWR CN-FM CN-RMT CN-STM CN-DISP CN-TH Figure Figure 4 To remove discharge grille Figure 5 94

95 To remove control board Figure To remove cross flow fan and indoor fan motor Figure 7 Figure 8 95

96 Figure 9 Figure 0 96

97 6.3 Outdoor Electronic Controller Removal Procedure 6.3. CU-YE9QKE CU-YE2QKE CU-UE9QKE CU-UE2QKE Caution! When handling electronic controller, be careful of electrostatic discharge. 5. Remove the Control Board as follows:. Remove the 3 screws of the Top Panel. Release 3 Terminal Connectors and 2 Earth Wire Screws Release 6 Connectors and 2 Reactor Connectors Remove 2 Screws Remove 2 Control Board Cover Screws Remove Screw Fig. 4 Fig. 2. Remove the 6 screws of the Front Panel. Fig. 2 Fig Remove the screw of the Terminal Board Cover. 4. Remove the Top Cover of the Control Board by 4 hooks. Electronic Controller Fig. 6 Fig Control Board

98 6.3.2 CU-UE8QKE Caution! When handling electronic controller, be careful of electrostatic discharge. 5. Remove the Control Board as follows:. Remove the 5 screws of the Top Panel. Fig. Fig Remove the 8 screws of the Front Panel. Fig Remove the screw of the Terminal Board Cover. 4. Remove the Top Cover of the Control Board by 4 hooks. Fig. 5 Fig. 6 Fig. 3 98

99 7. Technical Data Technical data provided are based on the air conditioner running under free frequency. 7. Cool Mode Performance Data Unit setting: Standard piping length, Hi Fan, Cool mode at 6 C Voltage: 230V 7.. CS-YE9QKE/CU-YE9QKE CS-UE9QKE/CU-UE9QKE Indoor ( C) DB WB Outdoor DB ( C) TC SHC IP TC SHC IP TC SHC IP TC SHC IP (Dry bulb value based on 46% humidity) 7..2 CS-YE2QKE/CU-YE2QKE CS-UE2QKE/CU-UE2QKE Indoor ( C) Outdoor DB ( C) DB WB TC SHC IP TC SHC IP TC SHC IP TC SHC IP (Dry bulb value based on 46% humidity) 7..3 CS-UE8QKE/CU-UE8QKE Indoor ( C) Outdoor DB ( C) DB WB TC SHC IP TC SHC IP TC SHC IP TC SHC IP (Dry bulb value based on 46% humidity) TC - Total Cooling Capacity (W) SHC - Sensible Heat Capacity (W) IP - Input Power (W) 99

100 7.2 Heat Mode Performance Data Unit setting: Standard piping length, Hi Fan, Heat mode at 30 C Voltage: 230V 7.2. CS-YE9QKE/CU-YE9QKE CS-UE9QKE/CU-UE9QKE Indoor ( C) DB Outdoor WB ( C) TC IP TC IP TC IP TC IP TC IP CS-YE2QKE/CU-YE2QKE CS-UE2QKE/CU-UE2QKE Indoor ( C) Outdoor WB ( C) DB TC IP TC IP TC IP TC IP TC IP CS-UE8QKE/CU-UE8QKE Indoor ( C) DB Outdoor WB ( C) TC IP TC IP TC IP TC IP TC IP TC - Total Cooling Capacity (W) SHC - Sensible Heat Capacity (W) IP - Input Power (W) 00

101 8. Service Data Service data provided are based on the air conditioner running under rated frequency during forced cooling / forced heating mode. 8. Cool Mode Outdoor Air Temperature Characteristic Condition - Indoor room temperature: 27 C DryBulb/9 C Wet Bulb - Unit setting: Standard piping length, forced cooling at 6 C, Hi fan - Compressor frequency: Rated for cooling operation - Piping length: 5m - Voltage: 230V 8.. CS/CU-YE9QKE CS/CU-UE9QKE Outlet Air ( C) Outdoor Air Temperature ( C) Current (A) Outdoor Air Temperature ( C).2 Low Pressure (MPa) Outdoor Air Temperature ( C) 0

102 8..2 CS/CU-YE2QKE CS/CU-UE2QKE Outlet Air ( C) Outdoor Air Temperature ( C) Current (A) Outdoor Air Temperature ( C).08 Low Pressure (MPa) Outdoor Air Temperature ( C) 02

103 8..3 CS/CU-UE8QKE Outlet Air ( C) Outdoor Air Temperature ( C) Current (A) Outdoor Air Temperature ( C) Low Pressure (MPa) Outdoor Air Temperature ( C) 03

104 8.2 Heat Mode Outdoor Air Temperature Characteristic Condition - Indoor room temperature: 20 C DryBulb/ - C Wet Bulb - Unit setting: Standard piping length, forced heating at 30 C, Hi fan - Compressor frequency: Rated for Heating operation - Piping length: 5m - Voltage: 230V 8.2. CS/CU-YE9QKE CS/CU-UE9QKE 40 Outlet Air ( C) Outdoor Air Temperature ( C) Current (A) Outdoor Air Temperature ( C) High Pressure (MPa) Outdoor Air Temperature ( C) 04

105 8.2.2 CS/CU-YE2QKE CS/CU-UE2QKE 40 Outlet Air ( C) Outdoor Air Temperature ( C) Current (A) Outdoor Air Temperature ( C) High Pressure (MPa) Outdoor Air Temperature ( C) 05

106 8.2.3 CS/CU-UE8QKE Outlet Air ( C) Outdoor Air Temperature ( C) Current (A) Outdoor Air Temperature ( C) High Pressure (MPa) Outdoor Air Temperature ( C) 06

107 8.3 Piping Length Correction Factor The characteristic of the unit has to be corrected in accordance with the piping length CS/CU-YE9QKE CS/CU-YE2QKE CS/CU-UE9QKE CS/CU-UE2QKE.02 Cooling Capacity Correction Factor Pipe Length (m) Heating Capacity Correction Factor Pipe Length (m) Note: The graphs show the factor after added right amount of additional refrigerant. 07

108 8.3.2 CS/CU-UE8QKE.03 Cooling Capacity Correction Factor Pipe Length (m).0.00 Heating Capacity Correction Factor Pipe Length (m) Note: The graphs show the factor after added right amount of additional refrigerant. 08

109 9. Exploded View and Replacement Parts List 9. Indoor Unit 9.. CS-YE9QKE CS-YE2QKE CS-UE9QKE CS-UE2QKE O/I 46 I/I 47 I/I 48 I/I 54 I/I 55 I/I 56 O/I 62 I/I 57 I/I 58 I/I 59 I/I 60 I/I Note The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts. 09

110 SAFETY REF. NO. PART NAME & DESCRIPTION QTY. CS-YE9QKE CS-YE2QKE REMARK CHASSIS COMPLETE CWD50C653 2 FAN MOTOR L6CBYYYL0037 O 3 CROSS-FLOW FAN COMPLETE CWH02C076 4 BEARING ASSY CWH64K007 5 SCREW - CROSS-FLOW FAN CWH EVAPORATOR CWB30C4829 CWB30C FLARE NUT (LIQUID) CWT FLARE NUT (GAS) CWT CLIP FOR SENSOR CWH3243 CONTROL BOARD CASING CWH TERMINAL BOARD COMPLETE CWA28C2364 O 3 ELECTRONIC CONTROLLER - MAIN CWA73C88 CWA73C89 O 5 ELECTRONIC CONTROLLER - INDICATOR CWA74676 O 6 SENSOR COMPLETE CWA50C222 O 23 CONTROL BOARD TOP COVER CWH INDICATOR HOLDER CWD CONTROL BOARD FRONT COVER CO. CWH3C DISCHARGE GRILLE COMPLETE CWE20C BACK COVER CHASSIS CWD FULCRUM CWH VERTICAL VANE 8 CWE CONNECTING BAR 2 CWE AIR SWING MOTOR CWA98264 O 34 CAP - DRAIN TRAY CWH HORIZONTAL VANE COMPLETE CWE24C REMOTE CONTROL COMPLETE CWA75C4453 CWA75C4455 O 37 FRONT GRILLE COMPLETE CWEC5835 O 38 INTAKE GRILLE COMPLETE CWE22C86 39 GRILLE DOOR COMPLETE CWE4C AIR FILTER 2 CWD00279 O 4 SCREW - FRONT GRILLE 2 XTT4+6CFJ 42 CAP - FRONT GRILLE 2 CWH DRAIN HOSE CWH INSTALLATION PLATE CWH BAG COMPLETE - INSTALLATION SCREW CWH82C OPERATING INSTRUCTION CWF INSTALLATION INSTRUCTION CWF INSTALLATION INSTRUCTION CWF BAG CWG SHOCK ABSORBER (L) CWG SHOCK ABSORBER (R) CWG C.C.CASE CWG INSTALLATION INSTRUCTION CWF INSTALLATION INSTRUCTION CWF INSTALLATION INSTRUCTION CWF INSTALLATION INSTRUCTION CWF INSTALLATION INSTRUCTION CWF INSTALLATION INSTRUCTION CWF INSTALLATION INSTRUCTION CWF

111 SAFETY REF. NO. PART NAME & DESCRIPTION QTY. CS-YE9QKE CS-YE2QKE REMARK 6 INSTALLATION INSTRUCTION CWF OPERATING INSTRUCTION CWF (NOTE) All parts are supplied from PAPAMY, Malaysia (Vendor Code: ). O marked parts are recommended to be kept in stock.

112 SAFETY REF. NO. PART NAME & DESCRIPTION QTY. CS-UE9QKE CS-UE2QKE REMARK CHASSIS COMPLETE CWD50C653 2 FAN MOTOR L6CBYYYL0037 O 3 CROSS-FLOW FAN COMPLETE CWH02C076 4 BEARING ASSY CWH64K007 5 SCREW - CROSS-FLOW FAN CWH EVAPORATOR CWB30C4829 CWB30C FLARE NUT (LIQUID) CWT FLARE NUT (GAS) CWT CLIP FOR SENSOR CWH3243 CONTROL BOARD CASING CWH TERMINAL BOARD COMPLETE CWA28C2364 O 3 ELECTRONIC CONTROLLER - MAIN CWA73C88 CWA73C89 O 5 ELECTRONIC CONTROLLER - INDICATOR CWA74676 O 6 SENSOR COMPLETE CWA50C222 O 23 CONTROL BOARD TOP COVER CWH INDICATOR HOLDER CWD CONTROL BOARD FRONT COVER CO. CWH3C DISCHARGE GRILLE COMPLETE CWE20C BACK COVER CHASSIS CWD FULCRUM CWH VERTICAL VANE 8 CWE CONNECTING BAR 2 CWE AIR SWING MOTOR CWA98264 O 34 CAP - DRAIN TRAY CWH HORIZONTAL VANE COMPLETE CWE24C REMOTE CONTROL COMPLETE CWA75C4455 O 37 FRONT GRILLE COMPLETE CWEC5836 O 38 INTAKE GRILLE COMPLETE CWE22C86 39 GRILLE DOOR COMPLETE CWE4C AIR FILTER 2 CWD00279 O 4 SCREW - FRONT GRILLE 2 XTT4+6CFJ 42 CAP - FRONT GRILLE 2 CWH DRAIN HOSE CWH INSTALLATION PLATE CWH BAG COMPLETE - INSTALLATION SCREW CWH82C OPERATING INSTRUCTION CWF INSTALLATION INSTRUCTION CWF INSTALLATION INSTRUCTION CWF ANTI-BACTERIAL FILTER CWD00C280 O 50 BAG CWG SHOCK ABSORBER (L) CWG SHOCK ABSORBER (R) CWG C.C.CASE CWG INSTALLATION INSTRUCTION CWF INSTALLATION INSTRUCTION CWF INSTALLATION INSTRUCTION CWF INSTALLATION INSTRUCTION CWF INSTALLATION INSTRUCTION CWF INSTALLATION INSTRUCTION CWF

113 SAFETY REF. NO. PART NAME & DESCRIPTION QTY. CS-UE9QKE CS-UE2QKE REMARK 60 INSTALLATION INSTRUCTION CWF INSTALLATION INSTRUCTION CWF OPERATING INSTRUCTION CWF (NOTE) All parts are supplied from PAPAMY, Malaysia (Vendor Code: ). O marked parts are recommended to be kept in stock. 3

114 9..2 CS-UE8QKE O/I 46 O/I 47 I/I 48 I/I 49 I/I 54 I/I 55 I/I 56 I/I 57 I/I 58 I/I 59 I/I 60 I/I CWH55025J CWH5505J a Note The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts. 4

115 SAFETY REF. NO. PART NAME & DESCRIPTION QTY. CS-UE8QKE REMARK CHASSIS COMPLETE CWD50C654 2 FAN MOTOR ARW7627AC O 3 CROSS-FLOW FAN COMPLETE CWH02C077 4 BEARING ASSY CWH64K00 5 SCREW - CROSS-FLOW FAN CWH EVAPORATOR CWB30C FLARE NUT (LIQUID) CWT FLARE NUT (GAS) CWT CLIP FOR SENSOR 2 CWH3243 CONTROL BOARD CASING CWH TERMINAL BOARD COMPLETE CWA28C2365 O 3 ELECTRONIC CONTROLLER - MAIN CWA73C820 O 5 ELECTRONIC CONTROLLER - INDICATOR CWA74676 O 6 SENSOR COMPLETE CWA50C222 O 23 CONTROL BOARD TOP COVER CWH INDICATOR HOLDER CWD a INDICATOR HOLDER CWD CONTROL BOARD FRONT COVER CO. CWH3C DISCHARGE GRILLE COMPLETE CWE20C BACK COVER CHASSIS CWD FULCRUM 2 CWH VERTICAL VANE CWE CONNECTING BAR CWE CONNECTING BAR CWE AIR SWING MOTOR CWA98K08 O 33 AIR SWING MOTOR CWA9824 O 34 CAP - DRAIN TRAY CWH HORIZONTAL VANE COMPLETE CWE24C REMOTE CONTROL COMPLETE CWA75C4297 O 37 FRONT GRILLE COMPLETE CWEC5837 O 38 INTAKE GRILLE COMPLETE CWE22C GRILLE DOOR COMPLETE CWE4C AIR FILTER 2 CWD00283 O 4 SCREW - FRONT GRILLE 3 XTT4+6CFJ 42 CAP - FRONT GRILLE 3 CWH DRAIN HOSE CWH INSTALLATION PLATE CWH BAG COMPLETE - INSTALLATION SCREW CWH82C OPERATING INSTRUCTION CWF OPERATING INSTRUCTION CWF INSTALLATION INSTRUCTION CWF INSTALLATION INSTRUCTION CWF BAG CWG SHOCK ABSORBER (L) CWG SHOCK ABSORBER (R) CWG C.C.CASE CWG INSTALLATION INSTRUCTION CWF INSTALLATION INSTRUCTION CWF INSTALLATION INSTRUCTION CWF INSTALLATION INSTRUCTION CWF

116 SAFETY REF. NO. PART NAME & DESCRIPTION QTY. CS-UE8QKE REMARK 58 INSTALLATION INSTRUCTION CWF INSTALLATION INSTRUCTION CWF INSTALLATION INSTRUCTION CWF INSTALLATION INSTRUCTION CWF ANTI-BACTERIAL FILTER CWD00C280 O (NOTE) All parts are supplied from PAPAMY, Malaysia (Vendor Code: ). O marked parts are recommended to be kept in stock. 6

117 9.2 Outdoor Unit 9.2. CU-YE9QKE CU-YE2QKE CU-UE9QKE CU-UE2QKE A B C Note The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts

118 SAFETY REF. NO. PART NAME & DESCRIPTION QTY. CU-YE9QKE CU-YE2QKE REMARK CHASSIS ASSY CWD50K SOUND PROOF MATERIAL CWG FAN MOTOR BRACKET CWD SCREW - FAN MOTOR BRACKET 2 CWH FAN MOTOR ARS64AC O 6 SCREW - FAN MOTOR MOUNT 4 CWH55252J 7 PROPELLER FAN ASSY CWH03K00 8 NUT - PROPELLER FAN CWH56053J 9 COMPRESSOR 5RS092XCD2 5RS02XBC2 O 0 ANTI - VIBRATION BUSHING 3 CWH50077 NUT - COMPRESSOR MOUNT 3 CWH CONDENSER CWB32C4027 CWB32C EXPANSION VALVE CWB05055 O 4 DISCHARGE MUFFLER (4-WAY VALVE) CWB200 O 5 HOLDER COUPLING CWH WAYS VALVE (LIQUID) CWB0280J CWB02589 O 7 3-WAY VALVE (GAS) CWB0374 O 9 REACTOR G0C03J0003 O 20 TERMINAL COVER CWH7039A 2 NUT - TERMINAL COVER CWH J 22 SOUND PROOF BOARD CWH572 23A SOUND PROOF MATERIAL CWG B SOUND PROOF MATERIAL CWG C SOUND PROOF MATERIAL CWG SENSOR CO - COMP TEMP CWA50C2205 O 25 CONTROL BOARD COVER - TOP CWH ELECTRONIC CONTROLLER - MAIN CWA73C846R CWA73C847R O 27 TERMINAL BOARD ASSY CWA28K036J O 28 CABINET SIDE PLATE CO. (RIGHT) CWE04C52 29 SENSOR CO-AIR TEMP AND PIPE TEMP CWA50C2764 O 30 CABINET SIDE PLATE CWE0403A 3 CABINET FRONT PLATE CO. CWE06C039 CWE06C36 32 CABINET TOP PLATE CWE0304A 33 PLATE - C. B. COVER TERMINAL CWH CONTROL BOARD COVER CO. CWH3C2 35 HANDLE CWE WAYS VALVE CWB00063 O 39 V-COIL COMPLETE (4-WAY VALVE) CWA43C243 O 4 V-COIL COMPLETE (EXP.VALVE) CWA43C2257 O 42 FLEXIBLE PIPE (L-TUBE) CWH PACKING - L.TUBE CWB ACCESSORY CO. (DRAIN ELBOW) CWG87C900 5 BAG CWG BASE BOARD - COMPLETE CWG62C SHOCK ABSORBER (RIGHT) CWG

119 SAFETY REF. NO. PART NAME & DESCRIPTION QTY. CU-YE9QKE CU-YE2QKE REMARK 54 SHOCK ABSORBER (LEFT) CWG C.C.CASE CWG (Note) All parts are supplied from PAPAMY, Malaysia (Vendor Code: ). O marked parts are recommended to be kept in stock. 9

120 SAFETY REF. NO. PART NAME & DESCRIPTION QTY. CU-UE9QKE CU-UE2QKE REMARK CHASSIS ASSY CWD50K SOUND PROOF MATERIAL CWG FAN MOTOR BRACKET CWD SCREW - FAN MOTOR BRACKET 2 CWH FAN MOTOR ARS64AC O 6 SCREW - FAN MOTOR MOUNT 4 CWH55252J 7 PROPELLER FAN ASSY CWH03K00 8 NUT - PROPELLER FAN CWH56053J 9 COMPRESSOR 5RS092XCD2 5RS02XBC2 O 0 ANTI - VIBRATION BUSHING 3 CWH50077 NUT - COMPRESSOR MOUNT 3 CWH CONDENSER CWB32C4027 CWB32C EXPANSION VALVE CWB05055 O 4 DISCHARGE MUFFLER (4-WAY VALVE) CWB200 O 5 HOLDER COUPLING CWH WAYS VALVE (LIQUID) CWB0280J CWB02589 O 7 3-WAY VALVE (GAS) CWB0374 O 9 REACTOR G0C03J0003 O 20 TERMINAL COVER CWH7039A 2 NUT - TERMINAL COVER CWH J 22 SOUND PROOF BOARD CWH572 23A SOUND PROOF MATERIAL CWG B SOUND PROOF MATERIAL CWG C SOUND PROOF MATERIAL CWG SENSOR CO - COMP TEMP CWA50C2205 O 25 CONTROL BOARD COVER - TOP CWH ELECTRONIC CONTROLLER - MAIN CWA73C846R CWA73C847R O 27 TERMINAL BOARD ASSY CWA28K036J O 28 CABINET SIDE PLATE CO. (RIGHT) CWE04C52 29 SENSOR CO - AIR TEMP AND PIPE TEMP CWA50C2764 O 30 CABINET SIDE PLATE CWE0403A 3 CABINET FRONT PLATE CO. CWE06C039 CWE06C36 32 CABINET TOP PLATE CWE0304A 33 PLATE - C. B. COVER TERMINAL CWH CONTROL BOARD COVER CO. CWH3C2 35 HANDLE CWE WAYS VALVE CWB00063 O 39 V-COIL COMPLETE (4-WAY VALVE) CWA43C243 O 4 V-COIL COMPLETE (EXP.VALVE) CWA43C2257 O 42 FLEXIBLE PIPE (L-TUBE) CWH PACKING - L.TUBE CWB ACCESSORY CO. (DRAIN ELBOW) CWG87C900 5 BAG CWG BASE BOARD - COMPLETE CWG62C SHOCK ABSORBER (RIGHT) CWG

121 SAFETY REF. NO. PART NAME & DESCRIPTION QTY. CU-YE9QKE CU-YE2QKE REMARK 54 SHOCK ABSORBER (LEFT) CWG C.C.CASE CWG (Note) All parts are supplied from PAPAMY, Malaysia (Vendor Code: ). O marked parts are recommended to be kept in stock. 2

122 9.2.2 CU-UE8QKE B A C Note The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts. 22

123 SAFETY REF. NO. PART NAME & DESCRIPTION QTY. CU-UE8QKE REMARK CHASSIS COMPLETE CWD52K277 2 SOUND PROOF MATERIAL CWG FAN MOTOR BRACKET CWD SCREW - FAN MOTOR BRACKET 2 CWH FAN MOTOR ARS64AC O 6 SCREW - FAN MOTOR MOUNT 4 CWH55252J 7 PROPELLER FAN ASSY CWH03K066 8 NUT - PROPELLER FAN CWH56053J 9 COMPRESSOR 5RD32XBE2 O 0 ANTI - VIBRATION BUSHING 3 CWH50077 NUT - COMPRESSOR MOUNT 3 CWH56000J 2 CONDENSER CWB32C EXPANSION VALVE CWB05055 O 4 DISCHARGE MUFFLER CWB200 O 5 HOLDER COUPLING CWH WAYS VALVE (LIQUID) CWB02589 O 7 3-WAY VALVE (GAS) CWB0806 O 9 REACTOR G0C93J0006 O 20 TERMINAL COVER CWH7039A 2 NUT - TERMINAL COVER CWH J 22 SOUND PROOF BOARD CWH A SOUND PROOF MATERIAL CWG B SOUND PROOF MATERIAL CWG C SOUND PROOF MATERIAL CWG SENSOR - COMPLETE COMP. TEMP CWA50C2894 O 25 CONTROL BOARD COVER - TOP CWH ELECTRONIC CONTROLLER - MAIN CWA73C82R O 27 TERMINAL BOARD ASSY CWA28K036J 28 CABINET SIDE PLATE CO. (RIGHT) CWE04C48 29 SENSOR CO - AIR TEMP AND PIPE TEMP CWA50C2893 O 30 CABINET SIDE PLATE CWE0466A 3 CABINET FRONT PLATE CO. CWE06C44 32 CABINET TOP PLATE CWE0348A 33 CONTROL BOARD COVER CWH3470A 34 CONTROL BOARD COVER - COMPLETE CWH3C WAYS VALVE CWB00063 O 39 V-COIL COMPLETE - 4-WAY VALVE CWA43C243 O 4 V-COIL COMPLETE - EXP.VALVE CWA43C2257 O 42 ACCUMULATOR CWB STRAINER CWB BAG - COMPLETE CWG87C BAG CWG BASE BOARD - COMPLETE CWG62C62 48 SHOCK ABSORBER (RIGHT) CWG SHOCK ABSORBER (LEFT) CWG C.C.CASE CWG (NOTE) All parts are supplied from PAPAMY, Malaysia (Vendor Code: ). O marked parts are recommended to be kept in stock. 23

124 24 [PAPAMY] Printed in Malaysia SZ23-0

CS-CE9NKE CS-CE12NKE CU-CE9NKE CU-CE12NKE TABLE OF CONTENTS WARNING

CS-CE9NKE CS-CE12NKE CU-CE9NKE CU-CE12NKE TABLE OF CONTENTS WARNING Order No: PAPAMY1207094CE Indoor Unit CS-CE9NKE CS-CE12NKE Outdoor Unit CU-CE9NKE CU-CE12NKE WARNING This service information is designed for experienced repair technicians only and is not designed for

More information

TABLE OF CONTENTS. Air Conditioner. Indoor Unit Outdoor Unit CS-NE9MKE CU-NE9MKE CS-NE12MKE CU-NE12MKE CS-XE9MKE-5 CU-NE9MKE CS-XE12MKE-5 CU-NE12MKE

TABLE OF CONTENTS. Air Conditioner. Indoor Unit Outdoor Unit CS-NE9MKE CU-NE9MKE CS-NE12MKE CU-NE12MKE CS-XE9MKE-5 CU-NE9MKE CS-XE12MKE-5 CU-NE12MKE Order No. PHAAM1107134C2 Air Conditioner Indoor Unit Outdoor Unit CS-NE9MKE CU-NE9MKE CS-NE12MKE CU-NE12MKE CS-XE9MKE-5 CU-NE9MKE CS-XE12MKE-5 CU-NE12MKE TABLE OF CONTENTS PAGE 1 Safety Precautions-----------------------------------------------

More information

CS-HE9NKE CS-HE12NKE CS-AE9NKE CU-HE9NKE CU-HE12NKE CU-AE9NKE TABLE OF CONTENTS WARNING

CS-HE9NKE CS-HE12NKE CS-AE9NKE CU-HE9NKE CU-HE12NKE CU-AE9NKE TABLE OF CONTENTS WARNING Order No: PAPAMY1207093CE Indoor Unit CS-HE9NKE CS-HE12NKE CS-AE9NKE Outdoor Unit CU-HE9NKE CU-HE12NKE CU-AE9NKE WARNING This service information is designed for experienced repair technicians only and

More information

CU-NE9PKE CU-NE12PKE CU-QE9PKE CU-QE12PKE CS-NE9PKE CS-NE12PKE CS-QE9PKE CS-QE12PKE. Destination North Europe TABLE OF CONTENTS WARNING

CU-NE9PKE CU-NE12PKE CU-QE9PKE CU-QE12PKE CS-NE9PKE CS-NE12PKE CS-QE9PKE CS-QE12PKE. Destination North Europe TABLE OF CONTENTS WARNING Order No: PAPAMY3072CE Indoor Unit CS-NE9PKE CS-NE2PKE CS-QE9PKE CS-QE2PKE Outdoor Unit CU-NE9PKE CU-NE2PKE CU-QE9PKE CU-QE2PKE Destination North Europe WARNING This service information is designed for

More information

CU-S9KKQ CU-S12KKQ CU-S18KKQ CU-S24KKQ CS-S9KKQ CS-S12KKQ CS-S18KKQ CS-S24KKQ WARNING

CU-S9KKQ CU-S12KKQ CU-S18KKQ CU-S24KKQ CS-S9KKQ CS-S12KKQ CS-S18KKQ CS-S24KKQ WARNING Order No: PHAAM1001037C3 Indoor Unit CS-S9KKQ CS-S12KKQ CS-S18KKQ CS-S24KKQ Outdoor Unit CU-S9KKQ CU-S12KKQ CU-S18KKQ CU-S24KKQ WARNING This service information is designed for experienced repair technicians

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05 TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation

More information

CU-2E15LBE CU-2E18LBE CU-3E18LBE CU-4E23LBE

CU-2E15LBE CU-2E18LBE CU-3E18LBE CU-4E23LBE Order No. PHAAM1003090C3 Outdoor Unit CU-2E15LBE CU-2E18LBE CU-3E18LBE CU-4E23LBE Air Conditioner Please file and use this manual together with the service manual for Model No. CS-E7LKEW CU-E7LKE CS-E7LKEW

More information

CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE

CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE Order No. MAC0512111C8 Air Conditioner CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE TABLE OF CONTENTS PAGE 1 Safety Precautions----------------------------------------------- 3 2 Specifications -----------------------------------------------------

More information

AIR CONDITIONER +8/10 C MO DE MO DE +8/10 C HEAT AIR SW ING POWERFUL/QUIET FAN SPEED TIMER ON SE T CANCEL OFF AC RC WARNING

AIR CONDITIONER +8/10 C MO DE MO DE +8/10 C HEAT AIR SW ING POWERFUL/QUIET FAN SPEED TIMER ON SE T CANCEL OFF AC RC WARNING AIR CONDITIONER MO DE ECONAVI O FF/O N MO DE +8/0 C HEAT TEMP POWERFUL/QUIET +8/0 C HEAT Indoor AIR SW ING TIMER ON SE T 2 3 OFF AC RC SE T CHECKCLOCK RESET Order No: PAPAMY5074CE FAN SPEED CANCEL Unit

More information

Air Conditioner CU-XE9PKUA CU-XE12PKUA CS-XE9PKUA CS-XE12PKUA. Destination U.S.A. Canada WARNING

Air Conditioner CU-XE9PKUA CU-XE12PKUA CS-XE9PKUA CS-XE12PKUA. Destination U.S.A. Canada WARNING Order No: PAPAMY1305056CE Air Conditioner Indoor Unit CS-XE9PKUA CS-XE12PKUA Outdoor Unit CU-XE9PKUA CU-XE12PKUA Destination U.S.A. Canada WARNING This service information is designed for experienced repair

More information

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER

More information

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español Split-type Air-Conditioner MXZ-3A30NA MXZ-4A36NA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Français Español ATTENTION This manual mentions

More information

WH-UD09CE8 WH-UD12CE8 WH-UD14CE8 WH-UD16CE8 WH-SDF09C3E8 WH-SDF12C9E8 WH-SDF14C9E8 WH-SDF16C9E8 WARNING

WH-UD09CE8 WH-UD12CE8 WH-UD14CE8 WH-UD16CE8 WH-SDF09C3E8 WH-SDF12C9E8 WH-SDF14C9E8 WH-SDF16C9E8 WARNING Order No. PHAAM1009094C2 Indoor Unit WH-SDF09C3E8 WH-SDF12C9E8 WH-SDF14C9E8 WH-SDF16C9E8 Outdoor Unit WH-UD09CE8 WH-UD12CE8 WH-UD14CE8 WH-UD16CE8 WARNING This service information is designed for experienced

More information

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

Operating Instructions Split System Air Conditioner

Operating Instructions Split System Air Conditioner Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This

More information

AIR-CONDITIONER SPLIT TYPE

AIR-CONDITIONER SPLIT TYPE FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE

More information

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner F566272 Operating Instructions Air Conditioner CS-C18FFH CS-C28FFH CU-C18FFH CU-C28FFH ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference.

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402 TECHNICAL & SERVICE MANUAL SA 79G SA 99G FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-79G-A 1 851 005 18 General (50Hz) & Europe SA-99G-A 1 851 005 19 SA 79G SA 99G REFERENCE

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Use and Care Manual. Model CPA12KH AIR CONDITIONER Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage

More information

Monobloc Air-to-Water Heatpump System

Monobloc Air-to-Water Heatpump System Order No. PHAAM1010087C2 Monobloc Air-to-Water Heatpump System Monobloc Unit WH-MDF09C3E8 WH-MDF12C9E8 WH-MDF14C9E8 WH-MDF16C9E8 WARNING This service information is designed for experienced repair technicians

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................

More information

AIR CONDITIONER INSTALLATION MANUAL

AIR CONDITIONER INSTALLATION MANUAL INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by

More information

LG Floor Standing Type Air Conditioner INSTALLATION MANUAL

LG Floor Standing Type Air Conditioner INSTALLATION MANUAL website http://www.lgservice.com e-mail http://www.lgeservice.com/techsup.html LG Floor Standing Type Air Conditioner INSTALLATION MANUAL LG IMPORTANT Please read this installation manual completely before

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO.

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO. TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA

More information

CU-HE9PKE CU-HE12PKE CU-AE9PKE CS-HE9PKE CS-HE12PKE CS-AE9PKE. Destination North Europe TABLE OF CONTENTS WARNING

CU-HE9PKE CU-HE12PKE CU-AE9PKE CS-HE9PKE CS-HE12PKE CS-AE9PKE. Destination North Europe TABLE OF CONTENTS WARNING Order No: PAPAMY3070CE Indoor Unit CS-HE9PKE CS-HE2PKE CS-AE9PKE Outdoor Unit CU-HE9PKE CU-HE2PKE CU-AE9PKE Destination North Europe WARNING This service information is designed for experienced repair

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED

More information

Air Conditioner CONTENTS CS-V7DKE CU-V7DKE CS-V9DKE CU-V9DKE CS-V12DKE CU-V12DKE. Order No. MAC0412062C2

Air Conditioner CONTENTS CS-V7DKE CU-V7DKE CS-V9DKE CU-V9DKE CS-V12DKE CU-V12DKE. Order No. MAC0412062C2 Order No. MAC0412062C2 CS-V7DKE CU-V7DKE CS-V9DKE CU-V9DKE CS-V12DKE CU-V12DKE Air Conditioner CONTENTS Page Page 1 Features 3 2 Functions 4 2.1. Remote Control 4 2.2. Indoor Unit 5 2.3. Outdoor Unit 6

More information

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6

More information

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 SERVICE MANUAL Room Air Conditioner Multi Split Wall-Mounted Type Indoor FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 NOTE: Before servicing the unit, please read this at first. Always contact with

More information

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6. TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

ROOM AIR CONDITIONER INSTALLATION MANUAL

ROOM AIR CONDITIONER INSTALLATION MANUAL ROOM AIR CONDITIONER INSTALLATION MANUAL ( Split Type) Please read this installation manual completely before installing the product When the power cord is damaged, replacement work shall be performed

More information

14. Troubleshooting Guide

14. Troubleshooting Guide 14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL CSKE1NB41 & CZ18BT1U + CUKE1NK1 CSKE18NB4UW & CZ18BT1U + CUKE18NKU DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) CSKE1NB41 (CZ18BT1U) CSKE18NB4UW (CZ18BT1U)

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL CSKS12NB41 & CZ18BT1U + CUKS12NK1A CSKS18NB4UW & CZ18BT1U + CUKS18NKU CSKS18NB4UW & CZ18BT1U + CUKS18NKUA DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel)

More information

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner P07-T10130 Operating Instructions Air Conditioner Indoor Unit CS-F24DD1E5 CS-F28DD1E5 CS-F34DD1E5 CS-F43DD1E5 CS-F50DD1E5 Outdoor Unit Inverter Model (HBE5 Series) CU-YL24HBE5 CU-YL28HBE5 CU-YL34HBE5 CU-YL43HBE5

More information

SiUS041111. Service Manual. Inverter Pair Wall Mounted Type K-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiUS041111. Service Manual. Inverter Pair Wall Mounted Type K-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type K-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type K-Series Cooling Only Indoor Unit FTXN09KEVJU

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries

More information

CEILING CASSETTE TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS

CEILING CASSETTE TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS CEILING CASSETTE TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS Please read this instruction sheet completely before installing the product. When the power cord is damaged, replacement work should be

More information

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Air Conditioner Water Heater - A Product of HotSpot Energy LLC Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform

More information

Dehumidifier Users manual. For Models: DH45S DH65S

Dehumidifier Users manual. For Models: DH45S DH65S Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

TABLE OF CONTENTS. Air Conditioner CS-E9HKEA CU-E9HKEA CS-E12HKEA CU-E12HKEA

TABLE OF CONTENTS. Air Conditioner CS-E9HKEA CU-E9HKEA CS-E12HKEA CU-E12HKEA Order No. MAC0801090C2 Air Conditioner CS-E9HKEA CU-E9HKEA CS-E12HKEA CU-E12HKEA TABLE OF CONTENTS PAGE 1 Safety Precaution ------------------------------------------------ 2 2 Specifications -----------------------------------------------------

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer

More information

SWIMMING POOL HEAT PUMP

SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL CS-KS30NKU + CU-KS30NKUA CS-KS36NKU + CU-KS36NKUA DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. CS-KS30NKU CS-KS36NKU Product Code No. 852 360 86

More information

Air Conditioner CONTENTS CS-TE9DKE CU-TE9DKE CS-TE12DKE CU-TE12DKE. Order No. RAC0502005C2

Air Conditioner CONTENTS CS-TE9DKE CU-TE9DKE CS-TE12DKE CU-TE12DKE. Order No. RAC0502005C2 Order No. RAC0502005C2 Air Conditioner CS-TE9DKE CU-TE9DKE CS-TE12DKE CU-TE12DKE CONTENTS Page Page 1 Features 2 2 Functions 3 2.1. Remote Control 3 2.2. Indoor Unit 4 2.3. Outdoor unit 5 3 Product Specifications

More information

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner

More information

Floor Type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MFZ-KA25VA MFZ-KA35VA MFZ-KA50VA. English

Floor Type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MFZ-KA25VA MFZ-KA35VA MFZ-KA50VA. English Floor Type Air-Conditioner MFZ-KA25VA MFZ-KA35VA MFZ-KA50VA INSTALLATION MANUAL This manual only describes the installation of indoor unit. When installing the outdoor unit, refer to the installation manual

More information

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER PORTABLE AIR CONDITIONER MAC 7500 Owner s Manual Air Conditioner Dehumidifier Oscillating Fan Please read this owner s manual carefully before operating the unit. POWERED BY 66126113.p65 17 INTRODUCTION

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL INDOOR UNIT : CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU CS-MKE18NKU CS-MKE24NKU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 7,500BTU / h 9,000BTU

More information

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6 TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE080528 Models KFTHP-12 KFTHP-18 KFTHP-24 CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL

More information

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE

More information

Reverse Cycle Inverter Split System Air Conditioner

Reverse Cycle Inverter Split System Air Conditioner Reverse Cycle Inverter Split System Air Conditioner Model Number TAC-09CHSA/JAI5 INSTALLATION MANUAL Contents 03 Warranty Details 04 Welcome 05 General Safety Instructions 06 Product Overview 07 Selecting

More information

PANASONIC TROUBLE SHOOTING GUIDE

PANASONIC TROUBLE SHOOTING GUIDE A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling

More information

Wall Mounted Mini Split Heat Pump Air Conditioner

Wall Mounted Mini Split Heat Pump Air Conditioner Wall Mounted Mini Split Heat Pump Air Conditioner OPERATING AND INSTALLATION MANUAL Model: KFIHP-09-ID / KFHIP-09-OD KFHHP-12-ID / KFHHP-12-OD Indoor Unit. Outdoor Unit. Thank you for selecting Soleus

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CM97 CM7 CM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No. CM97

More information

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ SERVICE MANUAL Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ FS2MI-147HFD FS2MI-187HFD FS3MI-217HFD FS3MI-277HFD FS4MI-277HFD FS4MI-367HFD FS5MI-367HFD NOTE: Before servicing the

More information

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477

More information

Split Type Room Air Conditioner. KSWM units

Split Type Room Air Conditioner. KSWM units OWNER S MANUAL Split Type Room Air Conditioner KSWM units Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.

More information

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0 Air Conditioner Service Manual 2 3 Model: AC-S13CG x 2 3 Content Technical specification.. 4 Performance curve.5 Outline & dimension of indoor unit..10 Outline & dimension of outdoor unit 11 Exploded view

More information

AIR CONDITIONER (SPLIT TYPE)

AIR CONDITIONER (SPLIT TYPE) OWNER S MANUAL AIR CONDITIONER (SPLIT TYPE) For general public use ENGLISH EN Indoor Unit RAS-07PKVP-E RAS-10PKVP-E RAS-13PKVP-E RAS-16PKVP-E RAS-18PKVP-E RAS-07PKVP-ND RAS-10PKVP-ND RAS-13PKVP-ND RAS-16PKVP-ND

More information

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE 4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement

More information

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF ASU5RLS AOU 9RLFW AOURLFW AOU5RLS R40A CONTENTS. DESCRIPTION OF EACH CONTROL

More information

OPTIONAL SLENDER REMOTE CONTROL

OPTIONAL SLENDER REMOTE CONTROL DAIKIN ROOM AIR CONDITIONER Operation Manual OPTIONAL SLENDER REMOTE CONTROL BRC944A2B READ BEFORE OPERATION Safety Precautions...2 Names of Functions of Parts...4 Preparation before Operation...5 OPERATION

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : AEMI0AH AEMIAHB AEMIAH AEMI0AH FILE NO. Destination: Europe DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity.0k.k.k.0k Outdoor Model No. AEMI0AH AEMIAHB AEMIAH

More information

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table

More information

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems Universal Split Systems If there is a fault on any LG Universal unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the fault will

More information

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R MAC120R MAC150R MAC 200R Serial # Fuji Clean USA 41-2 Greenwood Road Brunswick, Maine 04011 207-406-2729 www.macblowers.com MACBlowers The Intelligent

More information

SERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT

SERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT SPLIT-TYPE AIR CONDITIONERS Revision B: Descriptions regarding the outdoor fan motor have been corrected. Please void OBH549 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH549 REVISED

More information

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB98-29565A(1) ENGLISH ESPAÑOL

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB98-29565A(1) ENGLISH ESPAÑOL USER S MANUAL Duct Type Series MH MH FEEA Series FUEA Series ENGLISH ESPAÑOL PORTUGUÊS E HNIKA DEUTSCH ITALIANO FRANÇAIS Free Joint Multi Air Conditioner (Cooling and Heating) E S F I P D G DB98-29565A(1)

More information

SERVICE MANUAL OUTDOOR UNIT MUZ-A09NA,- 1,- U1,- U2 MUZ-A12NA,- U1 MUZ-A15NA,- U1 MUZ-A17NA,- U1 MUY-A15NA MUY-A17NA MUY-A24NA,- 1,- U1,- U2

SERVICE MANUAL OUTDOOR UNIT MUZ-A09NA,- 1,- U1,- U2 MUZ-A12NA,- U1 MUZ-A15NA,- U1 MUZ-A17NA,- U1 MUY-A15NA MUY-A17NA MUY-A24NA,- 1,- U1,- U2 SPLIT-TYPE AIR CONDITIONERS Revision E: MUZ-GA24NA and MUY-GA24NA have been added. Please void OB451 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OB451 REVISED EDITION-E Models MUZ-A09NA,-

More information

SWIMMING POOL HEAT PUMP Owners Manual

SWIMMING POOL HEAT PUMP Owners Manual SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor

More information

SPLIT -TYPE ROOM AIR CONDITIONER

SPLIT -TYPE ROOM AIR CONDITIONER Before using your air conditioner, please read this manual carefully and keep it for future reference SPLIT -TYPE ROOM AIR CONDITIONER Please read this installation manual completely before installing

More information

How To Measure Temperature On A Thermostat

How To Measure Temperature On A Thermostat Кондиционеры Mitsubishi Heavy Техническое руководство Кондиционеры настенного типа SRK20HD-S, SRK28HD-S, SRK40HD-S, SRK20CD-S, SRK28CD-S, SRK40CD-S CTENTS 1. GENERAL INFORMATI... 1 1.1 Specific features...

More information

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL Thank you for choosing our Air Conditioner. Please read this OWNER'S MANUAL carefully prior to use and keep it for further reference. CONTENTS Contents

More information

SYSTEM Inverter Air Conditioners

SYSTEM Inverter Air Conditioners OPERATION MANUAL SYSTEM Inverter Air Conditioners MODEL Ceiling Suspended type FXHQ12MVJU FXHQ24MVJU FXHQ36MVJU Read these instructions carefully before installation. Keep this manual in a handy place

More information

WINDOW ROOM AIR CONDITIONER

WINDOW ROOM AIR CONDITIONER WINDOW ROOM AIR CONDITIONER Installation and Operation Manual Electromechanical Remote Control CAPACITIES 220V - 60 HZ. 12,000; 18,000; 24000 BTU/HR 220V-240V - 50 HZ. 12,000; 18,000; 24000 BTU/HR Please

More information

Meaco 30L and Meaco 40L dehumidifier instruction manual

Meaco 30L and Meaco 40L dehumidifier instruction manual Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS

More information

DUCTED SPLIT TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS

DUCTED SPLIT TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS LN-IM-01 DUCTED SPLIT TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS Please read this instruction sheet completely before installing the product. When the power supply location is wanted to replace, replacement

More information

English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL. Français. R410A Split Series. Español MODELS FTXS15LVJU FTXS18LVJU FTXS24LVJU

English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL. Français. R410A Split Series. Español MODELS FTXS15LVJU FTXS18LVJU FTXS24LVJU English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split Series Español Français MODELS FTXS15LVJU FTXS18LVJU FTXS24LVJU Safety Precautions Read these Safety Precautions carefully to ensure

More information

SERVICE MANUAL MUZ-FE09NA MUZ-FE12NA MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-A. Models HFC

SERVICE MANUAL MUZ-FE09NA MUZ-FE12NA MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-A. Models HFC SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FE18NA has been added. Please void OBH543. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH543 REVISED EDITION-A Models MUZ-FE09NA MUZ-FE12NA MUZ-FE18NA Indoor

More information

SiUS091133. Service Manual. Inverter Pair FTXS-L Series FDXS-L Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiUS091133. Service Manual. Inverter Pair FTXS-L Series FDXS-L Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair FTXS-L Series FDXS-L Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair FTXS-L Series FDXS-L Series Cooling Only Indoor Unit FTXS30LVJU

More information

Taurus Series YORK Window Air Conditioners

Taurus Series YORK Window Air Conditioners Taurus Series YORK Window Air Conditioners IOM IOWRCAG50220711A1 Warning 1. Before using the Air conditioner please read the instructions carefully. They contain important advise about the installation,

More information

CEILING CASSETTE TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS

CEILING CASSETTE TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS CEILING CASSETTE TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS (Refrigerant : R-407C) This unit is charged with new refrigerant, R-407C. Be sure to use proper tools for R-407C, when installing the unit.

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL SAP-KRV9AEH + SAP-CRV9AEH SAP-KRV12AEH + SAP-CRV12AEH FILE NO. Destination: Europe DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. SAP-KRV9AEH SAP-KRV12AEH Product

More information

IH 17025 E Sigma Island 90

IH 17025 E Sigma Island 90 INSTRUCTIONS FOR USE Kitchen extractor hood Type: IH 17025 E Sigma Island 90 Dear Customer!! You are now a user of the newest generation kitchen extractor hood type IH 17025 E Sigma Island 90. This hood

More information