1 Acti 9 Advanced Communication Technology that Inspires Leading Future... >Innovative >Efficient >Reliable
2 About Schneider Electric About Schneider Electric As a global specialist in energy management, Schneider Electric offers integrated solutions across multiple market segments, including leadership positions in energy and infrastructure, industrial processes, building automation, and data centres/networks, as well as a broad presence in residential applications. Focused on making energy safe, reliable, and efficient, the Company is commited to help individuals and organizations Make the most of their energy. Our presence worldwide and in India Schneider Electric Worldwide 22.4 billion sales in % of sales in new economies people in 100+ countries 394 Rank in Fortune 500 ranking 4-5% Revenue devoted to R&D Schneider Electric in India* employees 10 + Distribution Centres 1 Regional Project & Engineering Centre 31 Global Manufacturing Plants R&D engineers in Bangalore *Figures as on April 2012
3 Acti 9 Advanced Communication Technology that Inspires Total Communication from POWER to FINAL Distribution Exclusively From Schneider Electric 1995 Masterpact NT/NW ACBs 2005 Compact NSX MCCBs 2012 Acti 9 MCBs, RCDs, DBs
4 5 generations of industry experience make Acti 9 the new reference in low-voltage modular systems
5 Acti 9 Advanced Communication Technology that Inspires > Protection Miniature circuit Residual current circuit Vigi residual current Surge arrester > Protection monitoring and Indication and tripping Remote control Automatic recloser auxiliaries Innovative Protection monitoring, Total control and DB level Efficient Manage loads, reduce operating and project costs, and accurately plan maintenance
6 > Control and Impulse Integrated control circuit Light Push-buttons and selector Kilowatt hour Communicating architecture > Installation Installation IP20B Splitter Full range of mounting and wiring accessories Reliable Dual certifications for one product, 100 percent MCB and RCD Coordination, easy ordering and design, error free fast connections
7
8 Contents Protection Devices 3-20 MCBs 3 RCDs 9 SPDs 15 Auxiliaries 19 Control & Indication Devices Communication Ready Devices Reflex ic60 24 ict Contactors 25 itl Impluse Relays 26 Smartlink 27 Energy Meters 28 Auxiliaries and Accessories 29 Basic Control & Indication Devices Isolators 30 Changeover Switches 31 Push buttons 32 Indicators 33 Bells and Buzzers 34 Time Switches 35 Technical Information Dimensions 36 Complimentary Technical Information 41 Protection Discrimination 53 Cascading 59 Applications
9 New range of MCBs, RCDs and DBs Protection devices Protection monitoring and supervision Installation systems Control and monitoring Global range for Indian Installations > MCBs suitable for higher ambient temperature - No De-rating required till 50 o C > SI version RCDs now also suitable for adverse environmental conditions - Assured protection in electrically polluted networks - Enhanced protection in corrosive and humid environment > Widest product range for every application - MCBs from 0.5A to 125A with 10kA to 50kA breaking capacity - RCDs upto 125A with 10mA 1000mA sensitivity - SPDs, Auxiliaries and accessories, Control and Indication devices Green Products 100% Recyclable and Recoverable REACH and RoHS compliant 2
10 Protection Devices Miniature Circuit Breakers (MCBs) > Protection against Overload and Short Circuit current fault > Protection of people against indirect contact in IT and TN earthing systems > Suitability for isolation in the industrial sector to IEC/EN Key Benefits Widest range: Precise solution for all application > 0.5A to 125A > High breaking capacity range - from 10kA to 50kA Low cost with higher performance: Cascading Cascading charts available From ACB-MCCB-MCB level Reduce Downtime: Discrimination Discrimination charts available From ACB-MCCB-MCB level Easy Installation: Bi connect terminals Increased service life: Fast Closing mechanism Field fittable auxiliaries available for advance protection and monitoring Field fittable Comm ready auxiliary for remote monitoring of: b Status of MCB - ON / OFF / Trip b Number of ON / OFF operations b Number of tripping due to faults b Number of running hours Green Products 100% Recyclable and Recoverable REACH and RoHS compliant Suitable for ComReady Auxiliary 3
11 Protection Devices Miniature Circuit Breakers (MCBs) xc60 10kA - IS/IEC ; IEC/EN kA - IEC Key Ensures no accidental contact with live part - Fingerproof IP-20 Operational Safety at the downstream - Suitabiltity for Avoids false insertion of cables and loose termination : Pull up Total Flexibiltity : Line-Load Field fittable auxiliaries available for advanced protection & Flexible termination of Busbars and Cables - Bi-Connect Suitable for DC application Breaking Capacity enhanced to 25kA as per IEC when backed by Compact NSX MCCBs Technical Data Parameter xc60 MCB Current Rating A Poles 1,2,3,4 Rated Voltage V Terminal Capacity Rigid cables upto 35 sqmm Flexible cables upto 25 sqmm Impulse Withstand Voltage 6KV Breaking Capacity 10KA as per IEC KA as per IEC Limitation Class 3 Operating Temperature -25 to 70 o C Suitable for ComReady Auxiliary MCB xc60 Poles 1P 2P 3P 4P **Module width - 18mm/Module Rating (A) References B Curve C Curve D Curve Module Width A9N1PD5C A9N1P01C A9N1P01D A9N1P02C A9N1P02D A9N1P03C A9N1P03D A9N1P04C A9N1P04D 1 6 A9N1P06B A9N1P06C A9N1P06D 1 10 A9N1P10B A9N1P10C A9N1P10D 1 16 A9N1P16B A9N1P16C A9N1P16D 1 20 A9N1P20B A9N1P20C A9N1P20D 1 25 A9N1P25B A9N1P25C A9N1P25D 1 32 A9N1P32B A9N1P32C A9N1P32D 1 40 A9N1P40B A9N1P40C A9N1P40D 1 50 A9N1P50B A9N1P50C A9N1P50D 1 63 A9N1P63B A9N1P63C A9N1P63D A9N2PD5C A9N2P01C A9N2P01D A9N2P02C A9N2P02D A9N2P03C A9N2P03D A9N2P04C A9N2P04D 2 6 A9N2P06B A9N2P06C A9N2P06D 2 10 A9N2P10B A9N2P10C A9N2P10D 2 16 A9N2P16B A9N2P16C A9N2P16D 2 20 A9N2P20B A9N2P20C A9N2P20D 2 25 A9N2P25B A9N2P25C A9N2P25D 2 32 A9N2P32B A9N2P32C A9N2P32D 2 40 A9N2P40B A9N2P40C A9N2P40D 2 50 A9N2P50B A9N2P50C A9N2P50D 2 63 A9N2P63B A9N2P63C A9N2P63D A9N3PD5C A9N3P01C A9N3P01D A9N3P02C A9N3P02D A9N3P03C A9N3P03D A9N3P04C A9N3P04D 3 6 A9N3P06B A9N3P06C A9N3P06D 3 10 A9N3P10B A9N3P10C A9N3P10D 3 16 A9N3P16B A9N3P16C A9N3P16D 3 20 A9N3P20B A9N3P20C A9N3P20D 3 25 A9N3P25B A9N3P25C A9N3P25D 3 32 A9N3P32B A9N3P32C A9N3P32D 3 40 A9N3P40B A9N3P40C A9N3P40D 3 50 A9N3P50B A9N3P50C A9N3P50D 3 63 A9N3P63B A9N3P63C A9N3P63D A9N4PD5C A9N4P01C A9N4P02C A9N4P02D A9N4P03C A9N4P03D A9N4P04C A9N4P04D 4 6 A9N4P06B A9N4P06C A9N4P06D 4 10 A9N4P10B A9N4P10C A9N4P10D 4 16 A9N4P16B A9N4P16C A9N4P16D 4 20 A9N4P20B A9N4P20C A9N4P20D 4 25 A9N4P25B A9N4P25C A9N4P25D 4 32 A9N4P32B A9N4P32C A9N4P32D 4 40 A9N4P40B A9N4P40C A9N4P40D 4 50 A9N4P50B A9N4P50C A9N4P50D 4 63 A9N4P63B A9N4P63C A9N4P63D 4 4
12 Protection Devices Miniature Circuit Breakers (MCBs) C120 10kA & 15kA IEC/EN , IEC Key C120N/H are higher rating MCBs for Overload and short-circuit Ensures no accidental contact with live part - Fingerproof IP-20 Avoids false insertion of cables and loose termination : Pull up Total Flexibiltity : Line-Load Operational Safety at the downstream - Suitabiltity for Field fittable auxiliaries available for advanced Longer product service life : Good overvoltage withstand capacity: products designed to offer a high industrial performance level Technical Data Parameter C120N C120H Current Rating 80,100,125 80,100,125A No. of Poles 1,2,3,4 1,2,3,4 Rated Voltage 240/415V 240/415V Terminal Capacity Rigid upto 50 sqmm Flexible upto 35 sqmm Rigid upto 50 sqmm Flexible upto 35 sqmm Impulse Withstand Voltage 6KV 6KV Breaking Capacity 10KA as per IEC KA per IEC Energy limiting class 3 3 Operating Temperature -30 to 70 o C -30 to 70 o C Suitable for ComReady Auxiliary MCB C120 Poles 1P 1 Rating (A) C120N References C Curve C120H Module Width 80 A9N18357 A9N A9N18358 A9N A9N18359 A9N P A9N18361 A9N A9N18362 A9N A9N18363 A9N P A9N18365 A9N A9N18367 A9N A9N18369 A9N P A9N18372 A9N A9N18374 A9N A9N18376 A9N **Module width - 18mm/Module 5
13 Protection Devices Miniature Circuit Breakers (MCBs) C60H-DC 250Vdc per Pole IEC/EN Exclusively designed to take care of all issues in DC installations to ensure complete Short circuit and Overload Protection Key Widest Range - 0.5A to Ensures no accidental contact with live part - Fingerproof IP-20 Avoids false insertion of cables and loose termination: Pull up Operational Safety at the downstream - Suitabiltity for Field fittable auxiliaries available for advanced protection & monitoring Technical Data Parameter C60H-DC No of Poles 1,2 Rated Voltage 250VDC (1P) 500VDC (2P) Terminal Capacity Rigid upto 35 sqmm Flexible upto 25 sqmm Impulse Withstand Voltage 6kV Breaking Capacity 6kA Energy limiting class 3 Operating Temperature -25 to 70 o C Suitable for ComReady Auxiliary MCB C60H-DC Poles 1P 1P 2P Rating (A) References Curve C 0.5 A9N61500 A9N A9N61501 A9N A9N61502 A9N A9N61503 A9N A9N61504 A9N A9N61505 A9N A9N61506 A9N A9N61508 A9N A9N61509 A9N A9N61510 A9N A9N61511 A9N A9N61512 A9N A9N61513 A9N A9N61514 A9N A9N61515 A9N A9N61517 A9N A9N61518 A9N A9N61519 A9N P Module Width 1 2 **Module width - 18mm/Module 6
14 Protection Devices Advanced MCBs for Specialized Applications ** NG125N (25kA) MCB Current Rating A Poles 1/2/3/4P Rated Voltage 240/415V Tripping Curves B,C,D Thermal Tripping 40 o C Breaking Capacity 25KA Degree of Pollution 3 Operating Temperature -30 to +70 o C Standard IEC/EN (NG125N 4P) (NG125H 4P) NG125H (36kA) MCB Current Rating 10-80A Poles 1,2,3,4 P Rated Voltage 240/415V Tripping Curves C Thermal Tripping 40 o C Breaking Capacity 36KA Degree of Pollution 3 Operating Temperature -30 to +70 o C Standard IEC/EN NG125L(50kA) MCB Current Rating 10-80A Poles 1,2,3,4P Rated Voltage 240/415V Tripping Curves B,C,D Thermal Tripping 40 o C Breaking Capacity 50KA Degree of Pollution 3 Operating Temperature -30 to +70 o C Standard IEC/EN UL MCB Type UL_1077 MCB UL_489 MCB Poles 1,2,3,4 1,2,3 Tripping Curves B,C C Voltage Rating 240/ /415V Breaking Capacity 10kA 10kA Degree of Pollution 3 3 Operating Temperature (-30 to 70 o C) (-30 to 70 o C) Standard IEC /UL 1077/CSA IEC / UL 489 C60NA-DC 20 A: 650 V DC 30 A: 500 V DC Operating voltage (Ue) 40 A: 400 V DC 50 A: 300 V DC Rated insulation voltage (Ui) 1,000 V DC Rated operational current (Ie) 50A Impulse voltage (Uimp) 6kV Number of poles 2P Standards IEC/EN ** For more details Please contact Schneider-Electric Customer Care Centre ( [email protected]) 7
15 New range of MCBs, RCDs and DBs Build your Installation Efficiently > Cost Efficient - Upto 40%* reduction in Control & Power wiring - Upto 25% savings on Installation cost by replacing conventional electrical panels by Distribution Boards > Time Efficient - Upto 15%* time savings on Design and Installation by using smart connections with pre-fabricated wiring > Space Efficient - Upto 35%* reduction in space utilization by using modular FD range Green Products 100% Recyclable and Recoverable REACH and RoHS compliant * Over conventional communication system 8
16 Protection Devices Residual Current Devices (RCDs) For Effective Protecton against > Electrocution due to Direct and Indirect Contact & Earth leakages > Personal Protection - 30mA > Fire Protection - 100mA & 300mA Key Benefits Widest range: Precise solution for all application > Rating up to 125A Easy monitoring: Earth fault indication on front face Immunity against nuisance tripping New SI RCDs offers enhanced immunity to electrical disturbances and polluted & corrosive environments Easy Installation: bi-connect terminals Field fittable auxiliaries for advanced protection & monitoring Field fittable Comm ready auxiliary for remote monitoring of: b Status of RCD - ON / OFF / Trip b Number of ON / OFF operations b Number of tripping due to faults b Number of running hours Green Products 100% Recyclable and Recoverable REACH and RoHS compliant Suitable for ComReady Auxiliary 9
17 Protection Devices Residual Current Devices (RCDs) xid & ID125 RCCBs IEC/EN , IS Key Current Rating upto Class AC - for normal installation Class Si - for electrically disturbed networks (with # harmonics, pulsating DC components etc.) & for harsh environments (presence of corrosive atmosphere chemical gases Front face trip on fault Finger-proof IP-20 terminals - ensures no accidental contact with live Test button to check Intermediate auxiliary required for add-on protection and indication ID125 RCCBs are suitable for indication OFsp auxiliary 4P RCCB is also suitable for 3phase 3 wire installation Technical Data Type xid* # xid # ID 125 Class AC Si AC/Si Current Rating 25-80A 25-63A 125A Sensitivity 30/100/300mA 30/300mA 30/100/300mA Poles 2,4 2,4 2,4 Rated Voltage V V V Rigid - 35 sqmm Rigid - 35 sqmm Rigid - 50 sqmm Terminal Capacity Flexible - 25 sqmm Impulse Withstand Voltage Operating Temperature Flexible - 25 sqmm 6KV 6KV 6KV Flexible - 35 sqmm -5 to 40 o C -25 to 40 o C -5 to 40 o C Suitable for ComReady Auxiliary RCDs xid & ID 125 Poles Type Rating (A) 2P AC SI References 30mA 100mA 300mA Module Width 25 A9N A9N A9N16204 A9N16205 A9N A9N16208 A9N16209 A9N A9N16212 A9N16213 A9N A9N A9N A9N16240 A9N P AC SI 25 A9N A9N A9N16254 A9N16255 A9N A9N16258 A9N16259 A9N A9N16261 A9N16262 A9N A9N A9N A9N16327 A9N *Contact Customer Care Centre for more details 10
18 Protection Devices Residual Current Devices (RCDs) DPN N Vigi RCBO IEC/EN Key Compact space saving design - 2Pole The DPN N Vigi residual current device provides complete protection for final circuits (against overcurrent and earth leakage faults) The new SI RCCB offers perfect protection in installations disturbed by: > extreme atmospheric conditions (humid, corrosive) > any type of electrical Avoids false insertion of cables and loose termination : Pull up Immune to nuisance tripping due to Transient overvoltages Technical Data Type AC Si Current Rating 6-40A 6-40A Sensitivity 30/300mA 30/300mA Poles 1P+N 1P+N Curve C C Rated Voltage V V Terminal Capacity Rigid upto 16 sq mm Rigid upto 16 sq mm Flexible upto 10 sq mm Flexible upto 10 sq mm Impulse Withstand Voltage 4kV 4kV Breaking Capacity 6kA 6kA Limitation Class 3 3 Operating Temperature -5 to 40 o C -25 o C to +60 o C Suitable for ComReady Auxiliary RCBO idpn N Vigi Poles 1P+N R N 1 N 2 Type AC SI Rating (A) 30mA References C Curve 300mA Module Width 6A A9N19661 A9N A A9N19663 A9N A A9N19665 A9N A A9N19666 A9N A A9N19667 A9N A A9N19668 A9N A A9N19669 A9N A A9N19631 A9N A A9N19632 A9N A A9N19634 A9N A A9N19635 A9N A A9N19636 A9N A A9N19637 A9N A A9N19638 A9N
19 Protection Devices Residual Current Devices (RCDs) Vigi xc60 (add on RCD - AC Type) IEC/EN mA/300mA Key Combined with xc60 circuit breaker, the Vigi xc60 provide: Protection against earth leakage, short circuit and Overload faults - add on block for xc60 Fault tripping is indicated by a red mechanical indicator on the front Combinations of Vigi xc60 + xc60 MCB - Flexibility to choose MCB (xc60 range) as per load Field fittable auxiliaries available Suitable for ComReady Auxiliary Technical Data Vigi xc60 Vigi C120 Type AC AC/A/Si Current Rating 25-63A 125A Sensitivity 30/100/300mA 30/ 300/500/300s/1000 mas Poles 2,4 2P,3P,4P Rated Voltage V V Rigid - 25A - 25 sq mm Rigid - 50 sq mm Terminal Capacity 63A - 35 sq mm Flexible - 25A -16 sq mm 63A - 25 sq mm Flexible - 35 sq mm Impulse Withstand 6KV Voltage 6KV Operating 5-5 Temperature C to +60 o C C to +60 o C-AC 25 o C to +60 o C-Si Add on RCD Block Vigi xc60 & Vigi C120 Type AC 2P Sensitivity References 30mA 100mA 300mA Module Width 25 A A9N26581 A9N26582 A9N A A9N26611 A9N26612 A9N A A9N18563 A9N P Module Width 25 A A9N26595 A9N26596 A9N A A9N26643 A9N26644 A9N A A9N18569 A9N
20 Protection Devices Advanced RCDs for Specialized Applications ** RED: a NEW range of Recloser Earth Leakage The RED provides solution that is: Simple: Complete product for protection against Earthleakage and resetting. Reliable: System is restored to operation quickly, in optimum safety conditions. Reclosure The built-in automatic recloser automatically recloses the residual current device after checking insulation of the If the installation is still faulty: in this case a new check willbe carried out in If the fault was temporary and has disappeared: the recloser automatically recloses the REDs. Current Rating A Voltage rating (Ue) 230 V AC Impulse withstand voltage (Uimp) 4 kv Sensitivity 30mA/300mA Class A (Protection in presence of DC components in the circuit) RED status indication Mechanical: by O-l (open-closed) 2-position lever Electrical: by 1 red indicator light on the front panel Terminal Capacity Flexible upto 25 sqmm Rigid upto 35 sqmm ** For more details Please contact Schneider-Electric Customer Care Centre ( [email protected]) 13
21 New range of MCBs, RCDs and DBs Exclusively From Schneider Electric Govern your System Efficiently > Reduced Downtime - Centralized and Detailed load control - Remote monitoring through universal MODBUS protocol - 100% preventive maintenance Green Products 100% Recyclable and Recoverable REACH and RoHS compliant 14
22 Protection Devices Surge Protection Devices For Effective Protection Against Surges caused due to: Direct Lightening Strike > Type 1 SPD Indirect Lightening Strike > Type 2 SPD Switching Surges > Type 2 SPD Key Benefits Withdrawable type: Easy Replacement Inbuilt SPD health indicator Special SPDs for photovoltaic application and low voltage applications Also available with remote signaling Unique Quick PRD SPDs with inbuilt MCB protection Remote monitoring possible via Smart Link through inbuilt indication auxiliary for SPD health status Green Products 100% Recyclable and Recoverable REACH and RoHS compliant 15
23 Protection Devices Surge Protection Devices (SPDs) PRD 125r Type 1+2 SPDs IEC T1 : IEC ,T2 EN Type 1 : EN ,Type 2 Key Integrated solution with type1 & type2 Surge Protection To protect against direct, indirect lightening surges and switching Fitted with a remote indication contact for end-of-life Low Response time - 25 Easy-to-replace withdrawable Level of protection (Up) < 1.5kV Technical Data PRD1 25r Operating frequency Iimp / Imax End-of-life indication By tunnel terminal Operating temperature Standards Local notification Remote notification Rigid Cable Flexible Cable Type 1 Type 2 50 Hz 25kA/40kA White: correct operation Red: at end of life 1 A/250 V AC 0.2 A/125 V DC mm² mm² -25 o C to +60 o C IEC T1 EN Type 1 IEC T2 EN Type 2 Continuous operating voltage (UC) 350 V SPD PRD 125r Poles Type Reference Module Width 1P P+N (Type1+2) 3P P+N Surge arresters Spare cartridge Phase Type 1 Type 2 Neutral PRD1 25r PRD1 25r 1P PRD1 25r 1P+N PRD1 25r 3P 3 x x PRD1 25r 3P+N 3 x x
24 Protection Devices Surge Protection Devices (SPDs) iprd Surge Arrestors Type 2 and 3 SPDs (Withdrawable Surge Arrestors) IEC T2 and EN Type 2 Key SPD Type 2 & Type Effective protection against b Indirect lightening surges b Switching Response time < 25 Brings down surge voltage level to less than 800V (which is much lesser than the safe voltage of 1.5kA of Sensitive-category 1 equipments) in SPD Type 3 Secondary protection: placed near the loads to be protected when they are at a distance of more than 30 m from the incoming surge - iprd8 Technical Data Main characteristics Operating voltage (Ue) Imax Type of Protection End of life indication: By mechanical indicator End of life remote indication Operating temperature Type of connection terminals White Red iprd Surge Arrestors 230/400 V AC 8kA to 65kA 65kA to 20kA - Type 2 & 8kA - Type3 In operation At end of life By contact NO, NC 250 V/ 0.25A -25 o C to +60 o C Rigid upto 25 sqmm Flexible upto 16 sqmm SPD iprd Poles References Imax/In Imax/In Imax/In Imax/In Module Width 1P 65 ka / 20 ka 40 ka / 15 ka 20 ka / 5 ka 8 ka / 2.5 ka A9L A9L16561 ** 1 A9L A9L A9L P+N A9L A9L16562 ** 2 A9L A9L A9L P A9L A9L16445 ** 3 A9L A9L A9L P+N A9L A9L16564 ** 4 A9L A9L A9L Spare cartridges for Type SPD Reference C iprd65r IT A9L16682 C iprd65r A9L16681 C iprd40r IT A9L16684 C iprd40, iprd40r A9L16685 C iprd20r IT A9L16686 C iprd20, iprd20r A9L16687 C iprd8r IT A9L16688 C iprd8, iprd8r A9L16689 C neutral All products A9L16691 Surge arrester/circuit breaker association Type of surge arrester Associated circuit breaker iprd65 Curve C 50 A iprd40 Curve C 40 A iprd20 Curve C 25 A iprd8 Curve C 20 A **SPDs with Remote notification 17
25 Protection Devices Surge Protection Devices (SPDs) Advanced SPDs for Specialized applications** iquick PRD : Compact : SPD + Inbuilt MCB Type 2 or Type 3 (Withrawable type) Operating frequency Operating voltage (Ue) Imax Rating Response time Operating temperature Remote indication end of life Status Indication Type2 Type3 50/60 Hz 230/400 V AC 40kA - High risk level 20kA - Moderate Risk level 8kA - Protection of the nearby loads located at more than <25ns -25 o C to +70 o C By the NO/NC remote indication contact 250 V AC / 2 A White - Operational Red - At the end of life iprc, ipri surge arresters Surge Protection for communication systems (Analog & Digital) Characteristics iprc ipri Number of protected lines 2 2 Limitation voltage (Up) 300 V 70 V Rated discharge current (8/20) (In) 10 ka 10 ka Maximum discharge current (8/20) (Imax) 18 ka 10 ka Response time < 500 ns < 1 ns Nominal impulse current 100 A 70 A Rated current (IN) 450 ma (up to 45 o C) 300 ma (up) Series resistor 2.2 O 4.7 O End-of-life information by Loss of dialling tone Loss of transmission iprd PV-DC surge arresters Surge Protection for Photovoltaic Applications IEC T2/EN Type 2 Type of network Response Time Short circuit current (ISCPV) Type of surge arresters End-of-life indication mode Operating temperature Rated Voltage Isolated direct current <25ns 30 A Type2 Available -25 o C to +60 o C VDC ** For more details Please contact Schneider-Electric Customer Care Centre ( [email protected]) 18
26 Protection Devices Auxiliaries for Protection Devices xc60 MCB C120 MCB OF+SD24* SD+OF OF MN MSU MX+OF OF.S xid RCCB DPN n Vigi RCBO Total flexibility all auxiliaries are Field fittable Clip-fit design does not require any tool to fit Ease selection Same aux is suitable for xc60 and C120 range of MCBs and RCCBs Modular Design fits in regular distribution boards Quality Assurance conform to global standards Advance protection and Control: b Undervoltage protection : MN b Overvoltage Protection : MSU b Remote tripping of Devices : MX+OF 19
27 Protection Devices Auxiliaries for Protection Devices (Tripping & Indication) MN Instantaneous Undervoltage Release Causes the device with which it is associated to trip when input voltage decreases (between 70 % and 35 % of Un) V, 48V AC Rated Voltage 48V DC Mechanical state Front face indicator Width in 18mm module 1 A9N26960 ( V, Reference Number 48V AC) A9N26961 (48V DC) MNx Independent of Supply Tripping of the associated device by opening of the control circuit A drop in the supply voltage does not trip the associated device. Rated Voltage 230V, 240V AC Mechanical state Front face indicator Width in 18mm module 1 Reference Number A9N26969 (230 V AC) A9N26971 (400 V AC) MNs Delayed Undervoltage Release Causes the device with which it is associated to trip when input voltage decreases (between 70 % and 35 % of Un No tripping in case transient voltage drops (up to 0.2s) Rated Voltage V AC Mechanical state Front face indicator Width in 18mm module 1 Reference Number A9N26923 MSU Overvoltage Release Cuts off the power supply by opening the device with which it is associated when the phase/neutral voltage is exceeded Rated Voltage 230V AC Mechanical state Front face indicator Width in 18mm module 1 Reference Number A9N26500 MX Shunt Release Trips the associated device when it is powered on Emergency stop via a normally-open pushbutton V, 48V, 12-24V AC, Rated Voltage V, 48V, 12-24V DC Mechanical state Front face indicator Width in 18mm 1 module A9N26476 ( V AC, VDC) Reference Number A9N26478 (12-24VAC/ DC) A9N26477 (48 V A/DC) OF+SD/OF On/Off + Trip on Fault auxiliary Double open/closed or fault indicating contact. Two-in-one product: OF+SD or OF+OF V AC Rated Voltage V DC Test function Front Face Mechanical state indicator Front face Width in 18mm module 0.5 Reference Number A9N26929 OF (On/Off) Changeover contact indicating the "open" or "closed" position of the associated device Rated Voltage V AC V DC Test function Front face Width in 18mm module 0.5 Reference Number A9N26924 OF.S Changeover contact indicating the "open" or "closed position of the associated device V AC Rated Voltage V DC Width in 18mm module 0.5 Reference Number A9N26923 Compulsory for the addition of tripping or indication auxiliaries on xid RCCBs OF+SD24 Double changeover contact which can report to Acti 9 smartlink or programmable logic controller: Electrical fault Actuation of the tripping auxiliary Open/Closed position of the associated device. Rated Voltage 24V DC Test function on toggle Mechanical state Front face indicator Width in 18mm module 0.5 Reference Number A9N26899 SD Faull indicating contact Changeover contact indicating position of associated device in event of electrical fault Rated Voltage V AC V DC Test function Front face Width in 18mm module 0.5 Reference Number A9N
28 Control and Indication Devices 21
29 Acti 9 Advanced Communication Technology that Inspires... Acti 9 Smartlink: the heart of the system 11 input/output channels Exclusively From Schneider Electric Protection monitoring Load control swit Meets the challenge of all your applications Detailed load control, reduced downtime, and accurately planned maintenance 22
30 Ready to connect to any facility management solution PLC 24 V DC power supply Energy management system Internet Modbus network Building management system Modbus address encoders Modbus RS-485 connection ching Energy metering Quick and easy control wiring enables complete control of your installation Green Products 100% Recyclable and Recoverable REACH and RoHS compliant 23
31 Control and Indication Devices Communication Ready Devices Reflex ic60 IEC/EN Key Remote control by latched and/or impulse order according to 3 Circuit breaker provides protection against: b Overload currents b Short-circuit currents b Disconnection in the industrial 3 operating modes: For various For safe lock down: Integrated Simplified maintenance: Front face indicator allows better The Ti24 interface also allows fast, reliable connection of the Reflex ic60 to the Acti 9 Smartlink thanks to the prefabricated cables. ComReady Open to any Building Management System Technical Data Rating 10 to 63A Poles 2P/3P/4P Supply Voltage 230VAC - 50Hz 230 V AC - 5 ma Inputs (Y1/Y2) Control voltage V AC/DC Input (Y3) 24 V DC ma Rated impulse withstand Votlage Set to Disconnected - 6kV Set to Ready - 4kV Breaking capacity 20kA Operating Temp -25 o C to + 60 o C Terminal Capacity Power connection Control Connection upto 25A: Rigid: 25 sqmm; Flexible: 16sqmm above 25A : Rigid: 35 sqmm; Flexible: 25sqmm Power supply: Rigid : 10 sqmm; flexible: 6 sqmm Outputs: 2.5 sqmm Ti24 interface upto 1.5 sqmm Comm Ready Devices Type Rating 2P 3P 4P Curve (In) B C D B C D B C D Reflex ic60n With Ti24 interface 10A A9C61210 A9C62210 A9C63210 A9C61310 A9C62310 A9C63310 A9C61410 A9C62410 A9C A A9C61216 A9C62216 A9C63216 A9C61316 A9C62316 A9C63316 A9C61416 A9C62416 A9C A A9C61225 A9C62225 A9C63225 A9C61325 A9C62325 A9C63325 A9C61425 A9C62425 A9C A A9C61240 A9C A9C61340 A9C A9C61440 A9C A A9C61263 A9C A9C61363 A9C A9C61463 A9C Module Width
32 Control and Indication Devices Communication Ready Devices ict Contactors EN 61095, IEC Key For remote control applications in alternative networks: b lighting, heating,ventilation, roller blinds,sanitary hot water b mechanical ventilation systems, etc b load-shedding of non-priority 4 operating modes switch on front face: b Automatic mode b Temporary ON mode b Permanent ON mode b Mechanical contact position Safe installation maintenance: lock the contactor in ON position Technical Data Voltage rating (Ue) V 400 V AC Electrical Endurance (O-C) 100,000 cycles Insulation voltage (Ui) 500 V AC Pollution degree 2 Rated impulse withstand voltage (Uimp) 2.5 kv (4 kv for 12/24/48 V AC) Operating temperature -5 o C to +60 o C (1) Suitable for ComReady Auxiliary Open to any Building Management System Comm Ready Devices ict Contactors Rating Control Voltage Contact Reference Module Width AC7a AC7b (VAC) 25A 8.5A NO A9C A 6A NO A9C A 8.5A NO A9C A 15A NO A9C A 20A NO A9C A 8.5A NO A9C A 15A NO A9C A 20A NO A9C A 8.5A NO A9C A 15A NO A9C A 20A NO A9C A 20A NO+2NC A9C
33 Control and Indication Devices Communication Ready Devices itl Impulse Relay IEC/EN Key Used to control, by means of pushbutton, lighting circuits consisting of: b Incandescent lamps, low voltage, halogen lamps, etc. (resistive loads) b Florescent lamps, discharge lamps, etc. (inductive loads) b Safe maintenance: Disconnection of remote control by selector switch b Manual Controls on front face: 0-I toggle b Mechanical contact position indicator Technical Data Rating 16A/32A Voltage Rating VAC, 110V DC Terminal Capacity 16A Rigid: Upto 4 sqmm Flexible: Upto 4 sqmm 32A Rigid: Upto 4 sqmm Flexible upto 10sqmm Pollution degree 3 Rated impulse withstand voltage (Uimp) 6 kv Endurance (O-C) 100,000 cycles (AC22) Suitable for ComReady Auxiliary Open to any Building Management System Comm Ready Devices itl impulse relays Rating Module Poles 16A 32A A9C30811 A9C A9C30812 A9C A9C A9C A9C32816 A9C x A9C A9C30814 A9C x A9C
34 Control and Indication Devices Communication Ready Devices Smartlink (Heart of Acti 9 Communication The Acti 9 Smartlink transmits data from Acti 9 devices to a PLC or supervision system via the Modbus serial line communication Modbus processing interface providing: b Circuit Breaker status b Energy meter output b Contactor/Impulse relay control and Smart functions integrated b Energy counting from pulses b Average power calculation b Event counting b Running Fast, safe and simplified cabling: Pre-fabricated cables Smartlink Power Supply Rated Voltage 24 V DC ± 20 % Maximum input current 1.5 A Maximum inrush current 3A Meter Capacity 2 23 pulses per input Environmental characteristics Operating temperature -25 o C o C if vertical mounting, limited to 50 o C Degree of protection 3 Input characteristics Number of channels 11 2-input channels Maximum cable lengh 20 m Rated voltage 24 V DC Rated current 2.5 ma Output Characteristics Number of output channels 11 Rated voltage 24 V DC Maximum current 100 ma Terminal Capacity Rigid-0.5 to 1.5 mm² Flexible-0.5 to 1.5mm Type Set References Acti 9 Smartlink with V DC Supply 1 + ModbusConnector 1 A9XMSB11 + Locking clips for Multiclip 80A 2 Smartlink Accessories Accessories Link USB / Modbus for Acti 9 Smartlink test Prefabricated cables With 2 connectors With 1 connector Reference A9XCATM1 Short: 100 mm 6 A9XCAS06 Medium-sized: 160 mm 6 A9XCAM06 Long: 870 mm 6 A9XCAL06 Long: 870 mm 6 A9XCAU06 Connectors 5-pin 12 A9XC2412 connectors (Ti24) DIN rail (4 feet, 4 straps, 1 A9XMFA04 4 adapters) Mounting kit Multiclip 200 A 1 A9XM2B04 (4 adapters) Lock for Multiclip 80A Spare parts 1 A9XMLA02 (2 clips) 27
35 Control and Indication Devices Communication Ready Devices Energy Meters IEC and IEC Key Digital kilowatt-hour meters designed for sub-metering of active energy (rms) consumed by a single-phase or three-phase electriccircuit with or without distributed neutral. Technical Data Designation iem2000t ime Rating 0-40 A 0-63 A Accuracy Class 1 1 Consumption < 10 VA 2.5 VA Operating Temperature -25 to 65o C if < 32 A -25 to 55 o C if = 32 A -25 to 55 o C LED light indicator Consumption: 0.3 W Service Life: 100,00 hours ComReady Energy Meters Phase Voltage Metering Reference Number Module Width Single + Neutral 230, +20% 3,200 flashes/kwh A9MEM2000T 1 1,000 flashes/kwh A9M Three 400, ±20% 100 flashes/kwh A9M Three + Neutral 230, +20% 100 flashes/kwh A9M
36 Control and Indication Devices Communication Ready Devices Auxiliaries & Accessories iact24 (Control and Indication) Auxiliary for Contactors: Allows a contactor to be interfaced with the Acti 9 Smartlink interface or a programmable logic controller in 24 V DC 230V AC (Y2) Control Voltage 24V DC (Y3) Insulation Voltage 250V AC Rated Impulse 8KV Withstand Voltage Pollution Degree 3 Width in 18mm module 1 Operation Voltage -25 to + 60 o C Reference Number A9C15924 iatl24 (Control and Indication) Auxiliary for Impulse Relays: Allows an impulse relay to be interfaced with the Acti 9 Smartlink interface or a programmable logic controller in 24 V DC 230V AC (Y2) Control Voltage 24V DC (Y3) Insulation Voltage 250V AC Rated Impulse 8KV Withstand Voltage Pollution Degree 3 Width in 18mm module 1 Operation Voltage -25 to + 60 o C Reference Number A9C15424 Multiclip 80 A It is a four-pole splitter block 24 modules wide installable on a standard DIN rail. Rated Current at 40 C 80A Maximum operating voltage 440 V AC Rated Insulated voltage 500 V AC Rated Impulse Withstand Voltage 6 KV Width in 18mm modules 24 Reference Number Distribloc 63A/125A splitter block 4P Splitter Block mountable on the DIN Rail and modular in shape Outgoing feeders are connected at the front,without screws, in spring terminals. The tunnel terminals are located to facilitate the insertion of cables and clamping by screws The spring contact pressure adapts automatically to the cross section of the conductor. It is independent of the operator. In the event of an extension to or modification of the switchboard, connection is very easy. Rigid: 25 sqmm Terminal Capacity Flexible: 16 sq mm Rated impulse 63A - 6kV withstand voltage (Uimp) 125A - 8kV Operating temperature -25 o C to +60 o C Voltage rating (Ue) 440VAC Module width 4Modules IEC/EN Standards IEC/EN rows of terminals: b 12 connection points for phases (L1, L2, L3) b 12 connection points for neutral. 29
37 Control and Indication Devices Basic Control and Indication Devices xsw Isolators IEC ; IEC Key Utilization category: Suitable for DC supply 1P - 48V DC, 2P (in series) - 110V Short circuit withstand 20In for Operational Safety at the downstream - Suitabiltity for Isolation Technical Data Current Rating 40A to 125A Rated Voltage VAC Insulated Voltage 500V AC Impulse Withstand Voltage 6KV Permissible rated short-time 1.25kA for 40A withstand current (Icw) 2.5kA for A Pollution Degree 3 Operating Temperature -20 to 50 o C Isolators xsw Biconnect Poles Rating Reference Number Module Width 2P A A9S2P A A9S2P A A9S2P P A A9S3P A A9S3P P A A9S4P A A9S4P A A9S4P xsw Monoconnect 2P A A9S2P A A9S2P P A A9S4P A A9S4P
38 Control and Indication Devices Basic Control and Indication Devices issw Changeover Switches IEC Key These linear switches are used for the manual control of electric Poles: 1P, Available in 2 2 Position (Source-1 - Source-2) and 3 Position (Source-1 - OFF - Swicthing Duty : AC-22 Technical Data Current Rating 20A Voltage Rating 250 V AC Endurance 30,000 cycles Pollution Degree 3 Operating Temperature -20 to 50 o C Terminal Capacity upto 10sqmm Pollution Degree 3 Operating Temperature -20 to 50 o C Changeover Switches (issw) Poles 2 positions Contact References Module Width 1P 1 Changeover Switch A9E Changeover Switches A9E NO + 1NC A9E P 3 positions Contact References Module width 1 Changeover Switch A9E Changeover Switches A9E
39 Control and Indication Devices Basic Control and Indication Devices ipb Switches Push Buttons IEC and IEC Key The pushbuttons are used to control electric circuits by means of pulses. Technical Data Current Rating 20A Voltage Rating 250 V AC Endurance 30,000 cycles Pollution Degree 3 Operating Temperature -35 to 70 o C LED light indicator Consumption: 0.3 W Service Life: 100,00 hours Push Buttons Single ipb Contact Pushbutton Colour Reference Number Module Width 1 NC Grey A9E Red A9E NO Grey A9E NO+1 NC Grey A9E Double ipb 1 NO/ 1 NC Green/ Red A9E NO/ 1 NO Grey/ Grey A9E Single + Indication light ipb Pushbutton Reference Contact Power Supply Light Colour Module Width Colour Number 1 NO Green A9E NC V AC Red A9E Grey 1 NO Green A9E NC V AC/DC Red A9E
40 Control and Indication Devices Basic Control and Indication Devices iil Indicator Lights Key LED Longer service Low power High visibility Technical Data Operating Frequency Hz Pollution Degree 3 Operating Temperature -35 to 70 o C LED light indicator Consumption: 0.3 W Service Life 100,00 hours Indicator Lights Single iil Colour Voltage Reference Number Module Width Red A9E Green A9E V AC Blue A9E Yellow A9E Double iil Green/ Red V AC A9E Flashing Light Red V AC A9E phase voltage presence indication light Red/ Red/ Red V AC (3 phase) A9E
41 Control and Indication Devices Basic Control and Indication Devices SO bells and iro buzzers Key Modular DB mounted bells & buzzers Technical Data 8-12 V AC VA Consumption V AC -- 5 VA IP40 (Device only) Degree of protection IP20 (Device in modular enclosure) Operating Temperature -10 to 40 o C SO - 80 dba Sound level (at a distance of 60cm) iro - 70 dba Control & Indication Devices SO Bell Voltage Reference Number Module Width 230 V AC V AC iro Buzzer 230 V AC A9A V AC A9A
42 Control and Indication Devices Basic Control and Indication Devices IH and IHP Time Switches Key Automatically switch On and Off loads according to the program entered by the user with 4 keys and a display, they operate on a weekly cycle: the same program is repeated week after Rating: 16A (can be used for application up to 100A with use of Memory: 56 switching operations and 84 switching Cycle - 24 hrs and/or Battery back up - 6years (by in-built Li Program from PC version also available 3mode operation - Available in Digital and Mechanical version Technical Data Designation IHP 1c IHP+1c IHP 2c IHP+2c IH+1c ARM IH 1c ARM Voltage Rating (V % 230 ±10% 230 ±10% AC) -15% Consumption 4 VA 7 VA 2.5 VA Degree of protection IP20B Operating Temperature -10 to 50 o C -20 to 55 o C -10 to50 o C Control & Indication Time Switches Type Number of channels Cycle period Minimum Time between 2 switching operations Reference Number Module Width IHP 1c 1 24h and/or 7d 1 min. CCT IHP + 1c 1 24h and/or 7d 1 s CCT IHP 2c 2 24h and/or 7d 1 min. CCT IHP + 2c 2 24h and/or 7d 1 s CCT IH + 1c ARM h + 7d 45 min. + 12h IH 1c ARM 1 24h 15 min A memory key (CT15861) and a programming kit (CCT15860) can be used to duplicate on another IHP+ 1C/2c or to save the program created by the contractor. 35
43 Technical Information Dimensions Protection Devices > MCB xc60 C120N, C120H 4P 3P 2P 1P C60H-DC NG125 N/L/H > RCDs xid RCCB RCCB-ID 125A 4 P 2 P Vigi xc60 25A Vigi xc60 63A P 3P 4P 2P 3P 4P 36
44 Technical Information Dimensions Protection Devices > SPDs PRD1 25r iprd 1P 1P+N 2P 3P 3P+N 4P Quick PRD 1P+N 3P 3P+N PRI PRC (Special Purpose SPDs) iprd PV-DC SPD
45 Technical Information Dimensions Protection Devices > Auxiliaries OF, SD, OF+SD/OF - MX, MN, MN s, MSU, MX+OF, MNx for DPN, DPN Vigi, C60, C120, ID / RCCB OF, SD, MN, MX, MNx, MN s for NG125 Ofs for ID / RCCB > Communication Ready Devices Reflex ic60 itl Impulse Relays 71 4P P 2P ict 16/25A ict 40/63A
46 Technical Information Dimensions Protection Devices Auxiliary for For ict - iact Auxiliary for itl Impulse Relays - iatl > Accessories Smartlink Multiclip Distribloc 63A Distribloc 125A Energy Meter
47 Technical Information Dimensions Protection Devices > Basic Control & Indication Devices xswitches (Bi-connect) xswitches (Mono-connect) 4P P 54 2P P P Biconnect 4 40 Monoconnect 4 Changeover switches Push Buttons Indicators SO Bells & iro Buzzzers IHP Time Switches 40
48 Technical Information Dissipated power Protection Devices MCBs The following table indicates the average dissipated power per pole in W for a current equal to the rating of the device and at the operating voltage. MCBs Rating(A) xc60/c60 H-DC C
49 Technical Information Influence of ambient temperature (Miniature Circuit Breakers) Tertiary/Industry (IEC ) C60 derating table (IEC ) C60 Ambient temperature ( C) Rating A A A A A A A A A A A A A A A A A A C60H-DC derating table (IEC ) C60H-DC Ambient temperature ( C) Rating A A A A A A A A A A A A A A A A A A C120 derating table (IEC ) C120 Ambient temperature ( C) Rating A A A
50 Technical Information Tripping curves (Miniature Circuit Breakers) Alternative current 50/60 Hz xc60 According to IEC/EN (reference temperature 30 C) Curves B, C, D Alternative current 50/60 Hz C120N/H According to IEC/EN (reference temperature 30 C) Curves B, C, D 3600 s for I/In = s for I/In = s for I/In = s for I/In = s for I/In = s for I/In = 2.55 t(s) 10 t(s) s for I/In = s for I/In = ,1 B C D 0,1 B C D 0, I / In 0, I / In Direct current C60H-DC According to IEC/EN (reference temperature 25 C) Curve C Alternative current 50/60 Hz Reflex ic60n/h According to IEC/EN (reference temperature 50 C) Curves B, C, D s for I/In = s for I/In= t(s) t(s) 1 1 0,1 C 0,1 B C D 0, I / In 0, ±20% 8 ±20% 12 ±20% I / In 43
51 Technical Information Short-circuit current limiting DB Isc Prospective peak Isc Limited peak Isc Limited Isc tc Prospective Isc Prospective current and real limit current. A² I²sc Prospective energy 100% Limited energy 100% t t Definition The limiting capacity of a circuit breaker is its ability to lessen the effects of a short circuit on an electrical installation by reducing the current amplitude and the dissipated power. Benefits of limiting Long installation service life Thermal effects Lower temperature rise at the conductor level, hence increased service life for cables and all components that are not self-protected (e.g. switches, contactors, etc.) Mechanical effects Lower electrodynamic repulsion forces, hence less risk of deformation or breakage of electrical contacts and busbars. Electromagnetic effects Less interference on sensitive equipment located in the vicinity of an electric circuit. Savings through cascading Cascading is a technique derived directly from current limiting: downstream of a currentlimiting circuit breaker it is possible to use circuit breakers of breaking capacity lower than the prospective short-circuit current (in line with the cascading tables). The breaking capacity is heightened thanks to current limiting by the upstream device. Substantial savings can be achieved in this way on switchgear and enclosures. Discrimination of protection devices The circuit breakers current limiting capacity improves discrimination with the protection devices located upstream: this is because the required energy passing through the upstream protection device is greatly reduced and can be not enough to cause it to trip. Discrimination can thus be natural without having to install a time-delayed protection device upstream. Acti 9 circuit breaker current limiting Profiting from Schneider Electric s experience and expertise in the field of shortcircuit current breaking, the circuit breakers of the Acti 9 range have a top-level current limiting characteristic for modular devices. This assures them of optimal protection of the entire power distribution system. 44
52 Technical Information Short-circuit current limiting (cont.) Representation: Current limiting curves The current limiting capacity of a circuit breaker is reflected by 2 curves which give, as a function of the prospective short-circuit current (current which would flow in the absence of a protection device): b the real peak current (limited) b the thermal stress (in A²s), this value, multiplied by the resistance of any element through which the short-circuit current passes, gives the power dissipated by this element. The straight line «10 ms» representing the energy A²s of a prospective short-circuit current of a half-period (10 ms) indicates the energy that would be dissipated by the short-circuit current in the absence of limiting by the protection device (see example) ms 400 Example What is the energy limited by an ic60n 25 A circuit breaker for a prospective short-circuit current of 10 ka rms. What is the quality of current limiting? > as shown in the graph opposite: b this short-circuit current (10 ka rms) is likely to dissipate up to 1,000 ka 2 s b the ic60n circuit breaker reduces this thermal stress to: 45 ka 2 s, which is 22 times less. Limited energy (A²s) Example of use: Stresses acceptable by the cables The following table shows the thermal stresses acceptable by the cables depending on their insulation, their composition (Cu or Al) and their cross section. Cross-section values are expressed in mm² and stresses in A²s S (mm²) PVC Cu 2.97 x x x x x 10 6 Al 5.41 x 10 5 PRC Cu 4.10 x x x x x 10 6 Al 7.52 x 10 5 S (mm²) PVC Cu 3.4 x x x x 10 7 Al 1.39 x x x x 10 7 PRC Cu 4.69 x x x x 10 7 Al 1.93 x x x x ,01 0, Prospective current (ka rms) 100 Example Is a Cu/PVC cable of cross section 10 mm² protected by a NG125L device? The above table shows that the acceptable stress is 1.32 x 106 A²s. Any short-circuit current at the point where a NG125L device (Icu = 25 ka) is installed will be limited, with a thermal stress of less than 2.2 x 105 A²s. (Curve on page ). The cable is therefore always protected up to the breaking capacity of the circuit breaker. 45
53 Technical Information Short-circuit current limiting (cont.) xc60 Limitation curves for network Ue: V AC (Ph/N V AC) 1P / 1P+N Peak current Thermal stress ms Peak current (ka) Peak current (ka) Prospective short-circuit current (ka eff.) Prospective short-circuit current (ka eff.) 100 xc60 Limitation curves for network Ue: V AC (Ph/N V AC) 2P / 3P / 4P Peak current Thermal stress ms Peak current (ka) Peak current (ka) Prospective short-circuit current (ka eff.) Prospective short-circuit current (ka eff.)
54 Technical Information Short-circuit current limiting (cont.) xc60 Limitation curves for network Ue: 440 V AC 2P / 3P / 4P Peak current Thermal stress ms Peak current (ka) Peak current (ka) Prospective short-circuit current (ka eff.) Prospective short-circuit current (ka eff.)
55 Technical Information itl impulse relays and ict contactors Choice of rating according to load type Control & Indication Devices Communication Ready Devices General comment Modular contactors and impulse relays do not use the same technologies. Their rating is determined according to different standards and does not correspond to the rated current of the circuit. For example, for a given rating, an impulse relay is more efficient than a modular contactor for the control of light fittings with a strong inrush current, or with a low power factor (non-compensated inductive circuit). Choice table Products itl impulse relays ict contactors Type of lamp 48 Unit power and capacitance of power factor correction capacitor Relay rating bbthe table below shows the maximum number of light fittings for each relay, according to the type, power and configuration of a given lamp. As an indication, the total acceptable power is also mentioned. bbthese values are given for a 230 V circuit with 2 active conductors (single-phase phase/ neutral or two-phase phase/phase). For 110 V circuits, divide the values in the table by 2. bbto obtain the equivalent values for the entire 230 V three-phase circuit, multiply the number of lamps and the maximum power output: vvby 3 (1.73) for circuits with 230 V between phases without neutral; vvby 3 for circuits with 230 V between phase and neutral or 400 V between phases. Note: The power ratings of the lamps most commonly used are shown in bold. For powers not mentioned, use a proportional rule with the nearest values. Maximum number of light fittings for a single-phase circuit and maximum power output per circuit 16 A 32 A 16 A 25 A 40 A 63/100 A Basic incandescent lamps, LV halogen lamps, replacement mercury vapour lamps (without ballast) 40 W W W W W W W 60 W 25 to 66 to 30 to 45 to 85 to 125 to 75 W W W W W W W 100 W W W W W W W W W W 500 W to 15 to 1000 W W W 1500 W ELV 12 or 24 V halogen lamps With 20 W W W W W W W ferromagnetic 50 W 28 to 74 to 10 to 15 to 27 to 42 to transformer 75 W W W W W W W 100 W With electronic 20 W W W W W W W transformer 50 W 25 to 65 to 25 to 39 to 76 to 114 to 75 W W W W W W W 100 W Fluorescent tubes with starter and ferromagnetic ballast 1 tube without 15 W W W W W W W compensation (1) 18 W 70 to 186 to 22 to 30 to 70 to 100 to 20 W W W W W W W 36 W W W W W W tube 15 W 5 µf W W W W W W with parallel to to compensation (2) 18 W 5 µf to 60 to 20 W 5 µf W W W W 36 W 5 µf W 5 µf W 7 µf W 7 µf W 7 µf W 16 µf or 4 tubes 2 x 18 W W W W W W W with series 4 x 18 W to 24 to 44 to 68 to compensation 2 x 36 W W W W W 2 x 58 W x 65 W x 80 W x 115 W
56 Technical Information itl impulse relays and ict contactors (cont.) Choice of rating according to load type Control & Indication Devices Communication Ready Devices Choice table (cont.) Products itl impulse relays ict contactors Type of lamp Unit power and Maximum number of light fittings for a single-phase circuit and maximum power output per circuit capacitance of power factor correction capacitor 16 A 32 A 16 A 25 A 40 A 63/100 A 5 20 µf Fluorescent tubes with electronic ballast 1 or 2 tubes 18 W W W W W W W 36 W 40 to 106 to 38 to 58 to 117 to 176 to 58 W W W W W W W 2 x 18 W x 36 W x 58 W Compact fluorescent lamps With external 5 W W W W W W Not tested electronic ballast 7 W 171 to 457 to 150 to 222 to 478 to 9 W W W W W W 11 W W W With integral 5 W W W W W W W electronic ballast 7 W 121 to 285 to 114 to 164 to 335 to 514 to (replacement for 9 W W W W W W W incandescent lamps) 11 W W W High-pressure mercury vapour lamps with ferromagnetic ballast without ignitor Replacement high-pressure sodium vapour lamps with ferromagnetic ballast with integral ignitor (3) Without 50 W Not tested, infrequent use W W W W compensation (1) 80 W 10 to 15 to 27 to 40 to 125 / 110 W (3) W W W W 250 / 220 W (3) / 350 W (3) W With parallel 50 W 7 µf W W W W compensation (2) 80 W 8 µf 9 to 13 to 25 to 38 to 125 / 110 W (3) 10 µf W W W W 250 / 220 W (3) 18 µf / 350 W (3) 25 µf W 40 µf W 60 µf Low-pressure sodium vapour lamps with ferromagnetic ballast with external ignitor Without 35 W Not tested, infrequent use W W W compensation (1) 55 W W to 9 to 14 to 24 to 90 W W W W W 135 W W With parallel 35 W W W W W W compensation (2) 55 W 20 µf 24 W 63 3 to 5 to 10 to 15 to 90 W 26 µf W W W W 135 W 40 µf W 45 µf
57 Technical Information itl impulse relays and ict contactors (cont.) Choice of rating according to load type Control & Indication Devices Communication Ready Devices Choice table (cont.) Products itl impulse relays ict contactors Type of lamp Unit power and capacitance of power factor correction capacitor Maximum number of light fittings for a single-phase circuit and maximum power output per circuit 16 A 32 A 16 A 25 A 40 A 63/100 A High-pressure sodium vapour lamps Metal-iodide lamps With ferromagnetic ballast with external ignitor, without compensation (1) With ferromagnetic ballast with external ignitor and parallel compensation (2) With electronic ballast 35 W Not tested, infrequent use W W W W 70 W 8 12 to 20 to 32 to 150 W W W W 250 W W W W 6 µf W W W W W W 70 W 12 µf 17 to 45 to 6 to 9 to 16 to 25 to 150 W 20 µf W W W W W W 250 W 32 µf W 45 µf W 60 µf W 85 µf W W W W W W W 70 W 29 to 77 to 18 to 29 to 51 to 76 to 150 W W W W W W W (1) Circuits with non-compensated ferromagnetic ballasts consume twice as much current for a given lamp power output. This explains the small number of lamps in this configuration. (2) The total capacitance of the power factor correction capacitors in parallel in a circuit limits the number of lamps that can be controlled by a contactor. The total downstream capacitance of a modular contactor of rating 16, 25, 40 or 63 A should not exceed 75, 100, 200 or 300 µf respectively. Allow for these limits to calculate the maximum acceptable number of lamps if the capacitance values are different from those in the table. (3) High-pressure mercury vapour lamps without ignitor, of power 125, 250 and 400 W, are gradually being replaced by high-pressure sodium vapour lamps with integral ignitor, and respective power of 110, 220 and 350 W. 50
58 Technical Information itl impulse relays and ict contactors (cont.) Control & Indication Devices Communication Ready Devices Heating application bbimpulse relay rating to be chosen according to the power to be controlled. 230 V heating Type Maximum power for a given rating itl impulse relays Single-phase circuit 16 A 32 A Heating (AC1) 3.6 kw 7.2 kw bbcontactor rating to be chosen according to the power to be controlled and the number of operations a day. 230 V heating Type of heating application Maximum power for a given rating ict contactors Number of 25 A 40 A 63 A 100 A operations / day kw 8.6 kw 14 kw 21.6 kw kw 8.6 kw 14 kw 21.6 kw kw 7.4 kw 12 kw 18 kw kw 6 kw 9.5 kw 14 kw kw 3.8 kw 6 kw 9 kw kw 2.7 kw 4.5 kw 6.8 kw 400 V heating kw 26 kw 41 kw 63 kw kw 26 kw 41 kw 63 kw kw 22 kw 35 kw 52 kw kw 17 kw 26 kw 40 kw kw 8 kw 13 kw 19 kw kw 6 kw 9 kw 14 kw Small motor application Contactor rating to be chosen according to the power to be controlled. Asynchronous single-phase motor with capacitor Small motor application type Maximum power for a given rating ict contactors Voltage 25 A 40 A 63 A 230 V Asynchronous three-phase motor 400 V Universal motor 230 V
59 Technical Information Influence of ambient temperature Control & Indication Devices Basic Control & Indication Switches bbin all cases, the switches are correctly protected against overloads by a circuit breaker with a lower or equal rating, operating at the same ambient temperature. ict contactors In the case of contactor mounting in an enclosure for which the interior temperature is in a range between 50 C and 60 C, it is necessary to use a spacer, cat. no. A9A27062, between each contactor. Spacer cat. no. A9A27062 Splitter blocks In the event of a temperature higher than 40 C, the maximum acceptable current is limited to the values in the table below: Type Temperature 40 C 45 C 50 C 55 C 60 C Multiclip 80 A Distribloc 63 A
60 Technical Information Protection discrimination Protection discrimination is an essential element that must be taken into account starting at the design stage of a low voltage installation to ensure the highest level of availability for users. Discrimination is important in all installations for the comfort of users, however it is fundamental in installations requiring a high level of service continuity, e.g. industrial manufacturing processes. Industrial installations without discrimination run a series of risks of varying importance including: production deadline overruns interruption in manufacturing, entailing: production or finished-product losses risk of damage to production machines in continuous processes restarting of machines, one by one, following a general power outage shutdown of vital safety equipment such as lubrification pumps, smoke fans, etc. What is discrimination? Discrimination, also called selectivity, is the coordination of automatic protection devices in such a manner that a fault appearing at a given point in a network is cleared by the protection device installed immediately upstream of the fault, and by that device alone. total discrimination Discrimination is said to be total if, for all fault current values, from overloads up to the non-resistive short-circuit current, circuit breaker D2 opens and D1 remains closed. partial discrimination Discrimination is partial if the above condition is not respected up to the full shortcircuit current, but only to a lesser value termed the selectivity limit current (Is). no discrimination In the event of a fault, both circuit breakers D1 and D2 open. Total discrimination as standard with Masterpact NT/NW circuit breakers Thanks to their highly innovative design and the exeptional performance of their control units, the Masterpact NT and NW circuit breakers offer total discrimination with downstream Compact NSX devices up to 630 A as standard (1). Natural discrimination with Compact NSX circuit breakers Due to the Roto-active breaking technique employed by the Compact NSX, the combined use of Schneider Electric circuit breakers provides an exceptional level of protection discrimination. This is the result of the implementation and optimisation of three different techniques: current discrimination time discrimination energy discrimination. Overload protection: current discrimination Discrimination is ensured if the ratio between setting thresholds is greater than 1.6 (for distribution circuit breakers). Low short-circuit protection: current discrimination. Tripping of the upstream device is slightly delayed to ensure that the downstream device trips first. Discrimination is ensured if the ratio between the short-circuit thresholds is greater than 1.5. High short-circuit protection: time discrimination. This protection system combines the exceptional current limiting capacity of the Compact NS and the advantages of reflex tripping, sensitive to the energy dissipated in the device by the short-circuit. In the event of a high short-circuit detected by two circuit breakers, the downstream device limits it sharply. The energy dissipated in the upstream device is not sufficient to trip it, i.e. discrimination is total for all short-circuit currents. Discrimination is ensured if the ratio between the circuit breaker ratings is greater than 2. (1) Except for the L1 performance level on Masterpact NT and subject to the discrimination rules on page 558E4300/7. 53
61 Technical Information Protection discrimination How to use the discrimination tables for discrimination between 2 distribution circuit breakers Combinations providing full discrimination are indicated by the symbol T. If discrimination is partial, the table indicates the maximum fault current value for which discrimination is ensured. For fault currents above this value, the 2 circuit breakers trip simultaneously. Requisite conditions Discrimination between two distribution circuit breakers. The values indicated in the tables are valid for operational rated voltages of 220, 380, 415 and 440V: Upstream Downstream Frame up / Frame down Thermal protection Ir up/ir down 54 Magnetic protection Im up/im down TM TM or Multi 9 u 2.5 u 1.6 u 2 Micrologic u 2.5 u 1.6 u 1.5 Micrologic TM or Multi 9 u 2.5 u 1.6 u 1.5 Micrologic u 2.5 u 1.3 u 1.5 These conditions ensure that curves don t overlap. Curves could also be checked with Curve Direct software tools D1 D2 RCD RCD Additional Settings conditions according to trip unit type Short time pick up (Isd) Tables indicate selectivity limits assuming Isd = 10 x Ir. In many cases when discrimination is Total lower thresholds could be used if ratio condition between two magnetic protections is fulfilled. When selectivity limit indicated in the tables is equal to 10xIr, the selectivity limit is upstream short time pick up (Isd). Instantaneous pick up (Ii) Tables indicate selectivity limits assuming instantaneous pick up is set at the maximum value and when it s inhibited (Type B Circuit breaker only). With Masterpact, when selectivity limit indicated in the tables is equal to 15 x In, the selectivity limit is upstream instantaneous pick up (Ii). When upstream circuit Breaker is A type, and downstream circuit breaker is B type upstream instantaneous setting can be set lower than 15 In as far as it stay higher than downstream circuit breaker reflex tripping limit. When a Micrologic 5.x is used downstream a Micrologic 2.x Tsd shall be set at 0 and Ii shall be set at Isd. Short time delay (Tsd) When upstream and downstream breaker are equipped with Micrologic 5.x, 6.x, 7.x: the minimum non tripping-time of the upstream device must be greater than the maximum tripping time of the downstream device. Tsd D1 > Tsd D2 (One Step) I2t Off / On Tables indicate selectivity limits assuming I2t Function is Off. If I2t function is ON user shall check curves. Ground Fault protection (Ig, Tg) When upstream and downstream breaker are equipped with Micrologic 6.x, user should implement current and time discrimination: current sensing discrimination Threshold setting of upstream GFP device tripping is greater than that of the downstream GFP device. Because of tolerances on the settings, a 30 % difference between the upstream and downstream thresholds is sufficient. time graded discrimination The intentional time delay setting of the upstream GFP device is greater than the opening time of the downstream device. Furthermore, the intentional time delay given to the upstream device must respect the maximum time for the elimination of insulation faults defined by the NEC (i.e. 1s for 3000 A). Ig D1 >= 1,3 Ig D2 Tg D1 > Tg D2 (One Step) Earth Leakage Protection (I, T ) When upstream and downstream breaker are equipped with Micrologic 7.x or Vigi user should implement current and time discrimination: current condition: The RCD must trip between IΔ and IΔ /2, IΔn where ln is the declared operating current. There must therefore exist a minimum ratio of 2 between the sensitivities of the upstream device and the downstream device. In practice, the standardised values indicate a ratio of 3. time condition: The minimum non-tripping time of the upstream device must be greater than the maximum tripping time of the downstream device for all current values. I n D1 u 3 x I n D2 t D1 > t D1 (One Step) Note : The tripping time of RCDs must always be less than or equal to the time specified in the installation standards to guarantee protection of people against indirect contacts. Compact NSX motor trip units Compact NSX Trip units dedicated to motor protection («M» type) can not be used to ensure discrimination with downstream circuit breaker. Furthermore Compact NSX trip unit dedicated to distribution should not be used to protect motors, even motors wit soft starter or speed drive.
62 Technical Information Protection discrimination Upstream: xc60, B curve Downstream: xc60, B, C, D curves Upstream xc60 B curve In (A) Downstream Rating Discrimination limit (A) xc60 B Curve /63 Discrimination limit (A) xc C Curve /63 Discrimination limit (A) xc D Curve / Discrimination limit = 400 A. No discrimination Note: respect the basic rules of discrimination, in terms of overcurrent, short-circuit, see page 6, or check curves with curve direct software. 55
63 Technical Information Protection discrimination Upstream: xc60, C curve Downstream: xc60, B, C, D curves Upstream xc60 C curve In (A) Downstream Rating Discrimination limit (A) xc60 B Curve /63 Discrimination limit (A) xc C Curve /63 Discrimination limit (A) xc D Curve / Discrimination limit = 400 A. No discrimination Note: respect the basic rules of discrimination, in terms of overcurrent, short-circuit, see page 6, or check curves with curve direct software. 56
64 Technical Information Protection discrimination Upstream: xc60, D curve Downstream: xc60, B, C, D curves Upstream xc60 D curve In (A) Downstream Rating Discrimination limit (A) xc60 B Curve /63 Discrimination limit (A) xc C Curve /63 Discrimination limit (A) xc D Curve / Discrimination limit = 400 A. No discrimination Note: respect the basic rules of discrimination, in terms of overcurrent, short-circuit, see page 6, or check curves with curve direct software. 57
65 Technical Information Protection discrimination Upstream: C120, H, B Curve Downstream: xc60, B, C, D curves Upstream C120H B curve In (A) Downstream Rating Discrimination limit (A) xc60 D Curve T T T T T T T T T T T T T T T T Discrimination limit = 400 A. No discrimination Note: respect the basic rules of discrimination, in terms of overcurrent, short-circuit, see page 6, or check curves with curve direct software. 58
66 Technical Information Cascading 220/240 V network downstream from a 380/415 V network For 1P + N or 2P circuit breakers connected between the phase and neutral on a 380/415 V network, with a TT or TNS neutral system, consult the 220/240 V cascading table to determinate cascading possibilities between upstream and downstream circuit breakers, for C60 upstream and consult the 380/415 V cascading table for idpn. For 1P + N or 2P circuit breakers connected to one phase of a 380/415 V network used together with the neutral to supply a single-phase circuit, consult the cascading tables for 380/415 V networks to determine the cascading possibilities between upstream and downstream circuit breakers. Example of three level cascading Consider three circuit breakers A, B and C connected in series. The criteria for cascading are fulfilled in the following two cases: the upstream device A is coordinated for cascading with both devices B and C (even if the cascading criteria are not fulfilled between B and C). It is simply necessary to check that the combinations A + B and A + C have the required breaking capacity each pair of successive devices is coordinated, i.e. A with B and B with C (even if the cascading criteria are not fulfilled between A and C). It is simply necessary to check that the combinations A + B and B + C have the required breaking capacity. The upstream breaker A is a NSX250L (breaking capacity 150 ka) for a prospective lsc of 80 ka across its output terminals. A NSX100B (breaking capacity 25 ka) can be used for circuit breaker B for a prospective lsc of 40 ka across its output terminals, since the «reinforced» breaking capacity provided by cascading with the upstream NSX250L is 50 ka. A C60H (breaking capacity 15 ka) can be used for circuit breaker C for a prospective lsc of 24 ka across its output terminals since the «reinforced» breaking capacity provided by cascading with the upstream NSX250L is 25 ka. Note that the «reinforced» breaking capacity of the C60H with the NSX100B upstream is only 20 ka, but: A + B = 50 ka A + C = 25 ka. 59
67 Technical Information Cascading 220/240 V Upstream: NSC100N Compact NSX Downstream: xc60, C120 Upstream NG160E NG160N NG160H NSC100N NSX100B NSX100F NSX100N NSX100H NSX100S NSX100L Breaking capacity (ka rms) Downstream Reinforced breaking capacity (ka rms) xc C120N C120H Upstream NSX160B NSX160F NSX160N NSX160H NSX160S NSX160L Breaking capacity (ka rms) Downstream Reinforced breaking capacity (ka rms) xc C120N C120H NG160E Cascading 220/240 V Upstream: Compact NSX250 Downstream: xc60, C120 Upstream NSX250B NSX250F NSX250N NSX250H NSX250S NSX250L Breaking capacity (ka rms) Downstream Reinforced breaking capacity (ka rms) xc C120N C120H
68 Technical Information Cascading, network 380/415 V Upstream: xc60, C120, NG125 Downstream: xc60, C120 Upstream C60H C120N C120H NG125N NG125H NG125L 15 32/40 A 20 50/ Downstream Breaking capacity (ka rms) xc C120N C120H
69 Complementary technical information Cascading, network 380/415 V Upstream: NSC100N Compact NSX Downstream: xc60, C120 NSC100N, Compact NSX Upstream NG160E NG160N NG160H NSC100N NSX100B NSX100F NSX100N NSX100H NSX100S NSX100L Breaking capacity (ka rms) Downstream Reinforced breaking capacity (ka rms) xc C120N C120H Upstream NSX160B NSX160F NSX160N NSX160H NSX160S NSX160L Breaking capacity (ka rms) Downstream xc60 y 40 A xc60 50 A and 63 A C120N C120H
70 Technical Information Cascading, network 380/415 V Upstream: Compact NSX Downstream: xc60, C120 Upstream NSX250B NSX250F NSX250N NSX250H NSX250S NSX250L Breaking capacity (ka rms) Downstream Reinforced breaking capacity (ka rms) xc60 y 40 A xc60 50 A and 63 A C120N C120H
71 New range of MCBs, RCDs and DBs Energy Efficiency from Power to Final Distribution EMC Certified > Up to 50% lesser power consumption compared to IEC Standards specification > Seamless connectivity to EMS and BMS by using Universal Modbus protocol > DB-mountable ComReady Meters metering energy usage from large sectors to individual loads Green Products 100% Recyclable and Recoverable REACH and RoHS compliant 64
72 Target Segments and Applications Targeted Segments Commercial (Metering/Monitoring) Hospitals (Metering/ Monitoring/ Control) Shopping Malls (Metering/Monitoring/ Control) Infrastructure (Monitoring/Control) Data Centre (Monitoring/Control) Applications: Data Centers Industrial premises Hospitals and Utilities Shopping Malls Commercial Establishments Residential townships Benefits: Reduction in electricity expenses up to 15% Solution scalability Ensuring occupant comfort while reducing operating costs Can precisely locate the fault area Reliability of data and Indications 65
73 Applications Specialized Application - Office Buildings Monitoring and Control of each zone on centralized HMI via Modbus through Acti 9 Smartlink Benefits For users > Reduction in electricity expenses by up to 15% through management of lighting or other devices, by optimization related to human presence. The user can perfectly control energy consumption for each zone. > Solution scalability in the event of reallocation or addition of zones. The Acti 9 system allows fast, reliable changes to the wiring in the switchboard. > Ensuring occupant comfort while reducing operating costs, through last detection and pinpointing in the event of a malfunction on an electrical switchboard 230/400V - 50Hz 1 C VDC power supply HMI Acti 9 Smartlink Modbus Meter 5 Office Lighting Office Lighting Coridor lighting PB for local lighting control PB for local lighting control Office Zone A Meter 9 Office Lighting Office Lighting Coridor lighting PB for local lighting control PB for local lighting control Office Zone B 66
74 Applications Specialized Application - Data Centers Status and control of individual load on centralized HMI via Enternet through Acti 9 Smartlink and GSM Modem Benefits For the end user Performance > The user is warned as soon as a protective device trips and he knows precisely where the fault is located. Reliability of data and indications > Low-level signalling contacts complying with IEC > High level of electromagnetic compatibility of the Acti 9 Smartlink modules. Ethernet 230/400V - 50Hz HMI GSM Modem Compact NSX 24 VDC power supply EGX100 Modbus RS VDC power Modbus RS485 Acti 9 Smartlink Multiclip Server (Rack) Lighting Load 67
75 Applications Specialized Application - Shopping Malls Status and control of individual load on centralized PC via Enternet through Acti 9 Smartlink Benefits For users > Reduction in electricity expenses by up to 30% through supervision allowing targeted actions > Optimization of investment with a system designed and optimized for electricity distribution, handling all the functions useful for operation. Ethernet Masterpact NT 230/400V - 50Hz Compact NSX Compact NSX 24 VDC power supply EGX100 Multiclip Modbus RS VDC power Modbus RS485 Acti 9 Smartlink Multiclip Lighting Load Lighting Load 68
76 Note
77 Note
78 Make the most of your energy Ahmedabad Schneider Electric India (P) Ltd. 41 B, 42 A, 4th Floor, Space House Opp. Sri Krishna Centre, Mithakall Six Roads, Ahmedabad Tel: / Fax: Bangalore Schneider Electric India (P) Ltd. 4th Floor, Electra, Wing A Exora Business Parks, Marathahalli, Sarjapur Outer Ring Road, Bangalore Tel: , Fax: Chandigarh Schneider Electric India (P) Ltd. SCO , 4th Floor, Sector-34-A Chandigarh Tel: /82/83/84 Fax: Chennai Schneider Electric India (P) Ltd. III Floor, DBS Westminister, No 108/5 Dr. Radhakrishan Salal, Mylapore Chennai Tel: Cochin Schneider Electric India (P) Ltd. 41/408, D1, BeeJay Towers, Above Qatar Airways, Rajaji Road Cochin Tel: /2/3 Fax: Coimbatore Schneider Electric India (P) Ltd. No. 104, 3rd Floor, Classic Tower, Trichy Road, Coimbatore Tel: / Fax: Jaipur Schneider Electric India (P) Ltd. Jaipur Business Centre 309, 3rd Floor Sangam Tower 190, Church Road, Jaipur Tel: / Fax: Jamshedpur Schneider Electric India (P) Ltd. The Business Centre Moti Bhavan Road No. 1 Contractor s Area, Bistupur Jamshedpur Tel: / Fax: Kolkata Schneider Electric India (P) Ltd. Technopolis, 3rd Floor, BP-4, Wing-B, Sector-V, Salt Lake City, Kolkata Tel: Fax: Lucknow Schneider Electric India (P) Ltd. 1st Floor, Asha Bhawan 27/II-A Gokhle Marg, Lucknow Tel: Fax: Ludhiana Schneider Electric India (P) Ltd. Office No. 3, 5th Floor, Novelty Plaza Bhai Walla Chowk, Ludhiana Tel: Fax: Mumbai Schneider Electric India (P) Ltd. Unit No. 1141, 1142 Building No. 11, 4th Floor, Solitaire Corporate Park Andheri Kurla Road, Chakala Andheri (E), Mumbai Tel: / Fax: Mumbai Schneider Electric India (P) Ltd., 2nd Floor, Marwah House, Kishanlal Marwah Marg, Off Saki Vihar Road, Marol, Andheri(E), Mumbai , Maharashtra. Tel: Fax: Nagpur Schneider Electric India (P) Ltd. Fortune Business Centre 6, Bashant Vihar, WS.C. Road, Shankar Nagar, Nagpur Tel: Fax: Pune Schneider Electric India (P) Ltd. 2nd Floor, R.B. Business Centre Above Dasa Electronics Sangvi Nagar, Aundh, Pune Tel: / Fax: Secunderabad Schneider Eleclric India (P) Ltd. D. No , # 102, Ashoka Bhoopal Chambers, SF. Road, Secunderabad Tel: / Fax: Vadodara Schneider Electric India (P) Ltd. 305, Concorde RC Dutt Road, Alkapuri, Vadodara Tel: /118 Fax: Vishakhapatnam Schneider Electric India (P) Ltd. Ratnam s Executive Centre D. No , 1st Floor Siripuram Fort, CBM Compound Vishakapatnam Tel: Fax: For more information visit our website at: Schneider Electric India Pvt. Ltd. (A 100% subsidiary of Schneider Electric Industries SAS) Corporate office : 9th Floor, DLF Building No.10, Tower C, DLF Cyber City, Phase II, Gurgaon , Haryana, Tel: , Fax: Customer Care Centre : Toll-free numbers: , , General number: , [email protected]
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
Easily connect your switchboards to facility management solutions
Easily connect your switchboards to facility management solutions Acti 9 communication system gives your customers complete control of their installations 100% exclusive to Schneider Electric Acti 9: The
SURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
Electrical auxiliaries 0 For i DPN (DPN), C60 and C120
Circuit protection For i DPN (DPN), C60 and C120 Function They remotely trip or indicate circuit-breakers, with or without Vigi module. Description b They are mounted to the left of the circuit-breaker
AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A
AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
Safety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
The complete range of consumer switchboards and switchgear
Power Distribution The complete range of consumer switchboards and switchgear www.nhp.com.au/mod6 The MOD6 range of consumer switchboards and switchgear is specifically designed for domestic and commercial
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
Breaking and protection devices
Breaking and protection devices 05 POWER GUIDE 2009 / BOOK 05 INTRO The purpose of selecting a protection device is to perform two essential functions: to protect people and to protect trunking, while
more than a breaker it s a breakthrough Compact NSX
Compact NSX, more than a breaker it s a breakthrough Compact NSX 100-630 A Intelligent outlook Today, we are living in an increasingly booming and fast changing world where energy is key. More than ever,
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
Merlin Gerin Multi 9 System Protection Miniature Circuit Breakers
Merlin Gerin Multi 9 System Protection Miniature Circuit Breakers Get more with the world s Power & Control specialist Protection Merlin Gerin Multi 9 System Miniature circuit breakers Tripping curves
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
A project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500
Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Description Firetrol FTA1500 Primary Resistance Fire Pump Controllers use resistors in the line to reduce line voltage
RCA Remote Control ic60 Circuit Breakers Reference Manual
9M01EN 01/2011 RC Remote Control ic60 Circuit reakers Reference Manual 01/2011 9M01EN www.schneider-electric.com The information provided in this documentation contains general descriptions and/or technical
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
Low Voltage Products. Switches Automatic Transfer Switches
Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,
Circuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
Permissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
How can a charging station for electric vehicles be set up simply and safely?
SB18 Building > Electromobility > Charging Station Design How can a charging station for electric vehicles be set up simply and safely? Requirement In order to supply electric vehicles with electric power,
ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
Sentron Series Circuit Breakers
Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of
Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
White paper. ABB solutions for switching and protection of low speed wind turbines
White paper ABB solutions for switching and protection of low speed wind turbines ABB solutions for switching and protection of low speed wind turbines Index 1 Introduction...2 2 Full converter configuration...4
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
Products and solutions for lifting systems
Products and solutions for lifting systems 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters founded
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
Maximum Demand Control
Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A
Low voltage electrical distribution Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A User manual 09/2009 User manual for circuit breakers and switch-disconnectors Masterpact
Wiring diagrams. Compact NSX. Contents
Compact NSX Wiring diagrams Contents Functions and characteristics A-1 nstallation recommendations B-1 Dimensions and connection C-1 Compact NSX100 to 630 Fixed circuit breakers D-2 Plug-in / withdrawable
Bulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA
w VOLTAGE MONITORING RELAY UR5U1011 w SCHRACK-INFO AC/DC voltage monitoring in 1-phase mains Undervoltage monitoring 1 change over contact Width 17.5 mm Installation design w TECHNICAL DATA 502 1. Functions
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
Thermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES
USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES 204.CAxxx 204.CBxxx 204.UBxxx 204.WBxxx MP36289 1 ZP90856-GB-6 INDICE 1 SYSTEM DESCRIPTION... 4 1.1 MODES OF OPERATION... 4 2 USER INTERFACE... 6 2.1
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
Catalog. Modular DIN rail components Installation contactors
Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation
Safety Relays ESM/ESM-F
Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
E-STOP relays, safety gate monitors
Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
PNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
ABB solutions for photovoltaics Protection and other modular devices
ABB solutions for photovoltaics Protection and other modular devices 2 ABB Component supplier for residential and power plant application ABB has been working for many years, as both a manufacturer and
Residual Current Circuit Breaker
Introduction Residual Current Circuit Breaker / ELCB The Fault current overloads and short circuits can be detected by circuit breakers like MCB s MCCB s & HRC Fuses etc. But, Circuit breakers don t detect
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches
Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class
SELECTION OF FINAL CIRCUIT PROTECTION
SELECTION OF FINAL CIRCUIT PROTECTION By Phil Williams, Product Marketing Manager, Power Distribution Components, Eaton Executive summary The selection of devices for final circuit protection in electrical
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
D-Line Contactors, Overload Relays and Accessories
D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................
Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole)
Overcurrentswitch,6A,2p,D-Char,AC Partno. FAZ-D6/2 Articleno. 278777 CatalogNo. FAZ-D6/2 Similar to illustration Deliveryprogramme Basic function Miniature circuit breakers Pole 2 pole Tripping characteristic
Electrical safety and protection devices
Electrical safety and protection devices RCD PROTECTION The easy, economical way to safeguard yourself when working with electricity. RCDs are specifically designed to minimise the risk of a fatal electric
38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
RY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
ELR: ABB range of front panel residual current relays Protection device according to IEC/EN 60947-2 Annex M
ELR: ABB range of front panel residual current relays Protection device according to IEC/EN 60947-2 Annex M Tested, certified, reliable Network monitoring and protection The electronic residual current
ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.
ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications. Ensuring operational continuity To ensure the operational continuity of an electrical
Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.
G Product page Inverters - Socomec G-1 Load break switches (Isolators) - Socomec G-2 Fuses - df G-3 Fuse bases Surge protection - df G-3 - Wohner G-5 - CPT G-4 - Dehn G-5 Connectors - Wieland G-6 Cable
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
Disturbance Recoder SPCR 8C27. Product Guide
Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power