Pilot Operated 2 Port Solenoid Valve for Dry Air

Size: px
Start display at page:

Download "Pilot Operated 2 Port Solenoid Valve for Dry Air"

Transcription

1 Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series Series VQ0 VCH VDW VQ LVM High frequency operation possible High speed response 7 ms or less (VQ0), 0 ms or less () (High speed response type without light/surge voltage suppressor at the supply pressure of 0.5 MPa) Long operating life Easy piping with One-touch Fittings Dusttight low jetproof enclosure (IP65) compliant in DIN terminal type. Application: Air-blow, Blow-off of workpiece, etc. 43

2 Pilot Operated For Dry Air Port Solenoid Valve Series VQ0/30 Single Unit [Option] How to Order Valves VQ A G C6 Series/ Orifice diameter Symbol 3 N.C. Series VQ0 Valve type (OUT) Option : None F: With bracket CE-compliant Q CE-compliant Made to Order specifications (Refer to the table below) A: Single unit (IN) Body type Manual override None Note) Slotted locking type B (tool required) Note) Only normally closed DIN terminal in-line style is applicable. L: Type L (VQ0 only) Note) If ordering both options, indicate LF. M: For manifold Note ) G: Grommet Coil voltage 00 VAC (50/60 Hz) 00 VAC (50/60 Hz) 0 VAC (50/60 Hz) 4 VDC VDC Other special voltage Note ) Please consult with SMC for special voltages. Note ) There is polarity for DC voltage (with power-saving circuit type). Y: DIN terminal YO: DIN terminal without connector Electrical entry Electricity circuit Symbol DC voltage With power-saving circuit (With surge voltage suppressor protection circuit) With power-saving circuit Z (With light/surge voltage suppressor protection circuit) Note) High speed response type H (Without energy-saving, light/surge voltage suppressor circuit) Note) H is available only for DC voltage and cannot be energized continuously. Made to Order Specifications Oil-free specifications VQ A 3M VQ A 3M Seal material fluororubber/oil-free specifications VQ A 3 M Note) Not available for manual operation. Port size Symbol Port size C6 C8 C0 C One-touch fitting for ø6 One-touch fitting for ø8 One-touch fitting for ø0 One-touch fitting for ø AC voltage With full wave rectifier circuit (With surge voltage suppressor protection circuit) With full wave rectifier circuit (With light/surge voltage suppressor protection circuit) VQ0 X(-Q) X5(-Q) X3(-Q) Please contact SMC for further specifications, delivery and price. Note) Please consult with SMC when using. Not available for manual operation. Seal material fluororubber specifications A 44

3 Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Standard Specifications VQ0 Valve specifications Series Valve construction Fluid Ambient and fluid temperature Lubrication Manual override Impact resistance/vibration resistance Enclosure Internal leakage cm 3 /min Exterior leakage cm 3 /min Mounting orientation Weight VQ0 port poppet pilot operated Note ) Air Note ) 0 to 50 C Not required Note 3) Slotted locking type (tool required) 50/30 m/s Note 4) Note 5) Dustproof 5 or less 5 or less Unrestricted 46 g 80 g Symbol (OUT) (IN) N.C. Electric specifications Coil rated voltage Allowable voltage fluctuation Coil insulation type VDC, 4 VDC, 00 VAC, 0 VAC, 00 VAC ±0% of rated voltage Class B or equivalent Power DC voltage (with power-saving circuit) Inrush:.9 W, Holding: 0.6 W consumption DC voltage (without power-saving circuit).9 W (Current value) AC VA Electrical entry Grommet, DIN terminal Note ) This product is for dry air. Use in clean air, and be sure that drain and oil content does not flow into the product. Note ) Use dry air to prevent condensation when operating at low temperatures. Note 3) Manual override is available only for DIN terminal type. Note 4) Vibration resistance: No malfunction occurred in a one-sweep test between 8.3 and 000 Hz. Test was performed at both energized and de-energized states to the axis and right angle directions of the main valve and armature (value at the initial state). Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed on the axis and right angle directions of the main valve and armature for both energized and de-energized states (value at the initial state). Note 5) DIN terminal type: Applicable to dusttight and low jetproof (IP65). Characteristic Specifications Series VQ0 Port size ø6 ø8 ø0 ø Flow characteristics C [dm 3 /(s bar)] b Cv Min. operating pressure differential Note 3) 0.0 MPa Max. operating pressure 0.6 MPa 0.5 MPa Note ) Note ) Electricity circuit With power-saving circuit High speed response type With power-saving circuit High speed response type Note ) Response time ON OFF 0 ms or less 5 ms or less 7 ms or less 5 ms or less 5 ms or less 5 ms or less 0 ms or less 5 ms or less VCH VDW VQ LVM Construction Note ) JIS B 8375 (value of DC voltage specifications at 0.5 MPa supply pressure) (Value of high response time is subject to change upon pressure, quality of air.) Note ) It cannot be used when energized continuously. Note 3) If a restrictor (nozzle, etc.) is mounted on the outlet side piping, the pressure differential when ON is smaller. Be sure that the pressure differential does not drop below 0.0 MPa. Additionally, take great care when used for the ejector supply, etc. w e q r t y u Component Parts No Description Solenoid coil Body Fixed armature Armature Return spring Poppet Diaphragm assembly Material Resin Stainless steel Stainless steel Stainless steel NBR H NBR, Resin 45 C

4 Series VQ0/30 Dimensions: Series VQ0 In-line Type: Grommet (G) VQA-G- - Mounting holes x ø3. through Bracket mounting holes x ø3. through Light Lead wire length Approx. 300 P port C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 Dotted line: Bracket mounting style (-F) 46

5 Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Dimensions: Series VQ0 Type L: Grommet (G) VQA-G- -L Light Lead wire length Approx. 300 VCH VDW P port C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 VQ LVM C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 x ø3. mounting hole Dotted line: Bracket mounting style (-LF) 47 A

6 Series VQ0/30 Dimensions: Series VQ0 In-line Type: DIN terminal (Y) VQA-Y- - Mounting hole x ø3. through Bracket mounting hole x ø3. through Manual override Applicable cable O.D. ø3.5 to ø7.0 mm P port C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 Dotted line: Bracket mounting style (-F) 48

7 Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Dimensions: Series In-line Type: Grommet (G) VQ3A-G- - Mounting hole x ø4.3 through Bracket mounting hole x ø4.5 through Light Lead wire length Approx. 300 VCH VDW VQ LVM P port C0: One-touch fitting for ø0 C: One-touch fitting for ø C0: One-touch fitting for ø0 C: One-touch fitting for ø Dotted line: Bracket mounting style (-F) 49

8 Series VQ0/30 Dimensions: Series DIN terminal (Y) VQ3A-Y- - Mounting hole x ø4.3 through Bracket mounting hole x ø4.5 through Manual override Applicable cable O.D. ø3.5 to ø7.0 mm P port C0: One-touch fitting for ø0 C: One-touch fitting for ø C0: One-touch fitting for ø0 C: One-touch fitting for ø Dotted line: Bracket mounting style (-F) 430

9 Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 How to Order Manifold VVQ 08 3 Series VQ0 Stations 0 station 0 0 stations Option D DO P port/thread type 00N 00T 00F CE-compliant Q CE-compliant Rc 3/8 NPT 3/8 NPTF 3/8 G 3/8 None DIN rail mounting DIN rail mounting (Without DIN rail) How to Order Manifold Assembly Enter the mounting valve and option part numbers under the manifold base part number. <Ordering Example> VVQ-05 (-Q) set Manifold part No. VQM-5G-C6 (-Q) 4 sets Valve part No. (Stations to 4) VQM-5G-C8 (-Q) set Valve part No. (Station 5) is the symbol for assembly. Add a in front of the part numbers for solenoid valves, etc., to be mounted. Stations 3 U side D side Enter together in order, counting from station on the D side. [Option] P How to Order Valves (For Manifold) Series/ Orifice diameter Symbol Series VQ0 3 Valve specifications M Manifold G Y YO Valve Type N.C. (OUT) VQ M G C6 (IN) Electrical entry Grommet DIN terminal DIN terminal (without connector) Note ) Coil voltage 00 VAC (50/60 Hz) 00 VAC 0 VAC 4 VDC VDC Other special voltage Note ) Please consult with SMC for special voltages. Note ) There is polarity for DC voltage (with power-saving circuit type). Electricity circuit Symbol Z H Note) Port size Symbol C6 C8 C0 C DC voltage With power-saving circuit (with surge voltage suppressor protection circuit) With power-saving circuit (with light/surge voltage suppressor protection circuit) High speed response type (without energy-saving, light/surge voltage suppressor circuit) Made to Order specifications Q (Refer to the table below) Port size One-touch fitting for ø6 One-touch fitting for ø8 One-touch fitting for ø0 One-touch fitting for ø VQ0 Manual override None B Note) Slotted locking type (tool required) Note) Only normally closed DIN terminal in-line style is applicable. Note) H is available only for DC voltage and cannot be energized continuously. CE-compliant CE-compliant AC voltage With full wave rectifier circuit (with surge voltage suppressor protection circuit) With full wave rectifier circuit (with light/surge voltage suppressor protection circuit) VCH VDW VQ LVM Made to Order Specifications Please contact SMC for further specifications, delivery and price. Oil-free specifications VQ 3 M X (-Q) Note) Please consult with SMC when using. Not available for manual operation. Seal material fluororubber specifications VQ 3 M X5 (-Q) 43 A

10 Series VQ0/30 Dimensions Plug lead unit manifold (VVQ- ) Mounting hole x ø4.5 through C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 x Rc 3/8 DIN rail mounting 4 x M3 x 0.5 Dotted line: DIN rail mounting (-D) Dimensions L L L L3 L4 L5 n Formulas L = (n ) x L = L 0 L3 = L4 0.5 L5 = L. n: Station (Max. 0)

11 Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Dimensions Plug lead unit manifold (VVQ3- ) Mounting hole x ø4.5 through C0: One-touch fitting for ø0 C: One-touch fitting for ø x Rc 3/8 VCH VDW VQ LVM DIN rail mounting 4 x M3 x 0.5 Dotted line: DIN rail mounting (-D) Formulas L = (n ) x L = L 0 L3 = L4 0.5 L5 = L. Dimensions n: Station (Max. 0) L n L L L L L

12 Series VQ0/30 Single Unit Option Bracket assembly (with mounting screws) For fixing this solenoid valve. Type VQ0 Grommet in-line type VQ0 Grommet L type, DIN terminal type DIN terminal L type Bracket assembly AXT835-3A AXT835-3A- AXT835-3A-3 AXT837-3A (Mounting screws, pcs.) M3 x 45 M3 x 40 M3 x 35 M4 x 45 Manifold Option DIN rail AXT00-DR- L.5 (Pitch) Suffix the number from DIN rail dimensions table below. Refer to the dimension drawing for each manifold for L dimension Each manifold can be mounted on a DIN rail. Order with the option symbol -D to specify DIN rail mounting style. The DIN rail is approximately 30 mm longer than the length of manifold. L dimension Series VQ0 Stations No. L Series Stations No L DIN rail mounting bracket VVQZ00-DB-5 This bracket is used for mounting the manifold on the DIN rail. DIN rail mounting bracket is attached on the manifold. set of DIN rail mounting brackets for manifold includes brackets. Blanking plate assembly (with O-ring and mounting screws) Mount a blank plate on valve manifold when a valve is disassembled for maintenance purposes, or when spare valve unit is supposed to be mounted in the future. Series VQ0 Blanking plate assembly AXT835-35A AXT837-35A (O-ring) OR H OR H (Mounting screws, pcs.) M3 x 6 M4 x 6 434

13 Series VQ0/30 Specific Product Precautions Be sure to read before handling. Refer to front matter 4 for Safety Instructions, and pages 7 to 9 for Port Solenoid Valves for Fluid Control Precautions. Warning Selection. Air quality This product is for dry air. Drain, oil, etc. in the air may result in faulty operation. Use clean (dry) air.. Pressure differential If a restrictor (nozzle, etc.) is mounted on the outlet side, the outlet side pressure differential at the inlet side is smaller. Be sure the pressure differential when ON does not drop below 0.0 MPa. Manual Override Warning Regardless of electric signals to the solenoid valve, the manual override is used for switching the main valve. (DIN terminal only.) Push the manual override Slotted locking type (tool required) button with a small flat head screwdriver until it stops. Turn it in the counterclockwise direction at ø to lock the manual. Turn it right to release. LED PUSH Timer circuit TURN LOCK Connection and Electrical Circuit Caution Black ( ) DC Blue (00 VAC) Red (00 VAC) Red (+) DC Blue (00 VAC) Red (00 VAC) With DC voltage power-saving circuit (with polarity) Lead wire color DIN connector Red (+) SOL. Connection and Electrical Circuit Caution Power wave form of power-saving type (Rated voltage at 4 VDC) Applied voltage 4 V 0 V 0 to 0 ms.9 W Power-saving 0.6 W 0 W AC circuit Lead wire color DIN connector Blue (00 VAC), Red (00 VAC) Blue (00 VAC), Red (00 VAC) Caution Valve Mounting When mounting the valve, secure with brackets. When mounting it directly, tighten the mounting screws with the appropriate torque (0.7 to 0.8 N m). Mounting screw Tightening torque 0.7 to 0.8 N m LED When Energizing Continuously for Long Period of Time SOL. Caution When energizing continuously, choose the option of an energysaving circuit specifications. High speed response type (with no energy-saving circuit) cannot be energized continuously. VCH VDW VQ LVM Black ( ) i i i: Inrush current, i: Holding current DC (with power-saving circuit) specifications is designed to reduce the power consumption at holding to achieve powersaving by circuit shown above. Refer to below power wave form. 435

14 Series VQ0/30 Specific Product Precautions Be sure to read before handling. Refer to front matter 4 for Safety Instructions, and pages 7 to 9 for Port Solenoid Valves for Fluid Control Precautions. How to Wire DIN Terminal Caution ISO#: Based on DIN 43650C (Pin gap 8 mm) Connection. Loosen the tightening screw and pull the connector off of the solenoid valve.. After removing the tightening screw, divide the terminal block and housing by prying open the slot area of the lower part of the terminal block open with a screwdriver. 3. Loosen the terminal screws of the block and insert stripped lead wires in accordance with the wiring diagram. Secure each wire by re-tightening the terminal screw (In the case of terminal : (+), : (-) DC) 4. Tighten the ground nut to secure the cable wire. Change of electrical entry Wire entry can be changed by mounting the housing in either direction (four directions at every 90 ) after dividing the terminal block and the housing. For the indicator lighted style, be careful not to damage the light with the lead wire of the cable. Precautions Insert a connector straight or pull it out straight, using caution it does not be tilted. Applicable cable Cord O.D.: ø3.5 to ø7 (Reference) 0.5 mm -core and 3-core wire equivalent to JIS C Ground nut Tightening torque.65 to.5 N m Washer Grommet (Rubber) (Voltage symbol) Refer to the following table Tightening torque 0. to 0.5 N m Terminal screw (3 positions) Tightening screw Tightening torque 0.3 to 0.4 N m Housing (Position for light mounting) Terminal block Shaved part DIN Terminal Part No. (Based on DIN) Without indicator light SY With Indicator Light Rated voltage Voltage symbol Part no. 4 VDC VDC 00 VAC 00 VAC 0 VAC 4 V V 00 V 00 V 0 V SY SY SY SY SY DIN Terminal Circuit with Indicator Light AC circuit How to Wire DIN Terminal NL R NL: Neon light R: Resistor Manifold How to Mount/Remove from DIN Rail Caution Removing procedure. Loosen the clamp screw on the A side of both ends of the manifold.. Lift the A side of the manifold off the DIN rail and slide it in the direction of the arrow. Mounting procedure. Hook the mounting hook on the B side of the manifold base to the DIN rail.. Press down side A and mount the end plate on the DIN rail. Tighten the clamp screw on side B of the end plate. (Tightening torque: 0.3 to 0.4 N m). Caution Valve Mounting DC circuit LED R LED: Light emitting diode R: Resistor After confirming the gasket is correctly placed under the valve, tighten the mounting screws with the appropriate torque (0.7 to 0.8 N m). A Manifold mounting screw B Manifold mounting screw 436

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large

More information

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00. Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm

More information

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3 Port Solenoid Valve 00/00/00 Metal Seal Rubber Seal 0. 0.9 (Standard) (High pressure type, High speed response type) Power consumption: 0. W/0.9 W Compact, High Flow Body ported Base mounted 00 00 00 00

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double 4/ Port Solenoid Valve Rubber Seal VZ1000/000/000 Solenoid Valve Variations Port Size Effective area (mm 2 ) Position solenoid Voltage Electrical entry Option/ Indicator light and surge voltage suppressor

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation

Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation Air Catch Sensor Series For Workpiece Placement Confirmation No-contact sensor for confirming workpiece placement, with a configuration that is less affected by supply pressure change. Easy-to-set-up LED

More information

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S. Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40 Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

1.8 w 101.2. 3 Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

1.8 w 101.2. 3 Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption Port Solenoid Valve Direct Operated Poppet Type Power consumption Vacuum applications New [Option] RoHS 4 Standard wtype (Existing product: 4.8 W) 0. kpa Energy-saving type.8 w (Existing product: W) A

More information

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100. Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Model position position Type of actuation

More information

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm) Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers

More information

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03. Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power

More information

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007 Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

STC 3S012-020-A Series Solenoid Valves

STC 3S012-020-A Series Solenoid Valves STC 3S012-020-A Series Solenoid Valves 3S012-020-A Series Solenoid Valve Specifications Valve Model 3S012-1/8-A 3S012-1/4-A 3S020-1/8-A 3S020-1/4-A Port Size (NPT) 1/8 1/4 1/8 1/4 Valve Type Action 3 Way,

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

Capacitive Prox E2K-X

Capacitive Prox E2K-X Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series

More information

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2 Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened

More information

2/2 and 3/2 Way Size 6 Seat Valves

2/2 and 3/2 Way Size 6 Seat Valves 2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Valves. Sub-Base Mounted Valves to ISO 5599/2

Valves. Sub-Base Mounted Valves to ISO 5599/2 Valves Sub-Base Mounted Valves to ISO 5599/2 General Information ISO 1, ISO 2 and ISO 3 valve series incorporate the famous Numatics lapped spool and sleeve for ultimate service life. Due to the great

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting Female NPT Thread 3/8 OD Tube 3/8 Push-In Fitting 2P050 Series Solenoid Valve Specifications Valve Model 2P050-1/4 2P050-3/8

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

DIAMOND Retractable Rodding Robot Model SPRAYROD-R 2004-12-21 2 1 (23) DIAMOND Retractable Rodding Robot Model SPRAYROD-R 2004-12-21 2 2 (23) Table of contents 1 TECHNICAL DESCRIPTION...4 1.1 MAIN DETAILS...5 1.2 COMPONENTS DESCRIPTION...5 1.2.1 Pneumatic

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

Adjustment functions for both span and shift have been incorporated

Adjustment functions for both span and shift have been incorporated SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED) NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate

More information

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits Vickers Check Valves Pilot Operated Check Valves PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series Typical Section Typical PCG5V model with internally drained pilot piston internal leakage through the closed pilot

More information

Solenoid valves 2/2-way direct-operated Type EV210A

Solenoid valves 2/2-way direct-operated Type EV210A Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral

More information

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large

More information

Line-Mounted Valves L Series

Line-Mounted Valves L Series Spare Part Kit for Valve Series B1LSAD3 Line-Mounted L Series Accessories Spare Part Kits All Series Valve Series B1LSAD3 40.1609 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

Solenoid valves Type EVU

Solenoid valves Type EVU Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot

More information

type V46, solenoid or pneumatic operated

type V46, solenoid or pneumatic operated SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

Solenoid Valve Island Type 3965

Solenoid Valve Island Type 3965 Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and

More information

VSO MAX HP High Flow Proportional Valve

VSO MAX HP High Flow Proportional Valve VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties

More information

TS93 EMR T/PT/TDE. Surface applied door closer

TS93 EMR T/PT/TDE. Surface applied door closer TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

Electro-Pneumatic Bus Door Control Mechanism

Electro-Pneumatic Bus Door Control Mechanism Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with

More information

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables. Quick-Connect Cables with Connectors PA Simplifies sensor wiring. Wide variety of connectors attached to cables. Series No wiring or staking work needed Shorter replacement time in unlikely event of sensor

More information

NAMUR Mount Hygienic Valve

NAMUR Mount Hygienic Valve NF097-D NMUR Mount Hygienic Valve For Wash Down pplications Series VFN Features Engineered Plastic PPS Body (Polyphenylene Sulfide) provides high temperature and chemical/corrosion resistance for use in

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.

More information

SOLENOID VALVE FOR REFRIGERATING SYSTEMS

SOLENOID VALVE FOR REFRIGERATING SYSTEMS SOLENOID VALVE FOR REFRIGERATING SYSTEMS FROM UALITY OUR NATURAL DEVELOPMENT Achieved the goal of fi fty years working in the industry of Refrigeration and Air Conditioning, Castel uality Range of Products

More information

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES 2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:

More information

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow 2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description

More information

Cooling system components, removing and installing

Cooling system components, removing and installing Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 2 A S E R I E S Catalogue 2005-2006 Directly operated solenoid valves Series A 2/2 way, 3/2 way monostable, bistable (with magnetic memory) Ports M5,, cartridge ø4 The Series A solenoid valves are of the

More information

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information Safety Safety Is Your Responsibility DANGER To avoid personal injury or death, carefully read and understand all instructions pertaining to the Anthony Liftgates product. Do not attempt to install, operate,

More information

G1/4 Q8. Standard with biased position

G1/4 Q8. Standard with biased position Contents Version Actuation Page Characteristics Dimensions x / Way Valves pneumatic 6,7, 0 9 electric 6,7 9, 9 / Way Valves pneumatic 6,7, 0 electric 6,7, 0 / Way Valves pneumatic 6,7,, 6, 7 electric 6,7,,

More information

Cooling system components, removing and installing

Cooling system components, removing and installing Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate

More information

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0. ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD SWITCHES FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.2g) Solder terminal type with mounting holes (0.3g)

More information

IOM SERIES 820-E/P Electro-Pneumatic Positioner

IOM SERIES 820-E/P Electro-Pneumatic Positioner FLUID CONTROL DIVISION Parker Hannifin Corporation 95 Edgewood Avenue New Britain, CT 06051 Telephone (860) 827-2300 IOM SERIES 820-E/P Electro-Pneumatic Positioner INSTALLATION, OPERATING & MAINTENANCE

More information

http://www.daikinpmc.com/en/ For latest information, PDF catalogs and operation manuals Features MPa {kgf/cm 2 } 100 17.5 {175}

http://www.daikinpmc.com/en/ For latest information, PDF catalogs and operation manuals Features MPa {kgf/cm 2 } 100 17.5 {175} Solenoid Valve Features 2 For DC power supply 3 For C power supply These models realize high-pressure large-flow-rate control at 35 MPa {35 kgf/cm 2 } and 1 L/min (2) or 16 L/min (3). They are best suited

More information

SQUARE D INDUSTRIAL CONTROL PRODUCTS

SQUARE D INDUSTRIAL CONTROL PRODUCTS SQUARE D INDUSTRIAL CONTROL PRODUCTS CLASS 9012 3a INDUSTRIAL PRESSURE SWITCHES Type A Heavy duty switch for virtually any industrial application involving air, water, steam or oil Bellows, piston and

More information

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation! 4 Small Micro Photoelectric Amplifier Built-in PM-44 SERIES PM-4 SERIES General terms and conditions... F- selection guide... P.44~ Related Information Glossary of terms / General precautions... P.39~

More information

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Valve Series VN Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Shuttle valves SSR -2 Check valves, direct operated RK / R CS SPZE SPV

More information

U-shaped Micro Photoelectric Sensor

U-shaped Micro Photoelectric Sensor SERIES U-shaped Micro Photoelectric Extremely small size enables space saving and quick installation! Extremely small Ultra-small type PM- 24(-R) contributes to the miniaturization of your equipment. Even

More information

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information Sealed Subminiature Basic Switch Sealed Basic Switch with Simplified Construction, Mounting Compatible with SS and D2SW Series. Sealing by using rubber packing means the switch can be used in dust-proof

More information

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC 8mm Solenoid Valve Typical Applications Portable Equipment Blood Pressure Monitoring Wound Therapy Air and Oxygen Delivery Sensor Zeroing Product Specifications Mechanical Valve Type: 3-Way, Solenoid-actuated

More information

Model Number Structure

Model Number Structure General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color) Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum

More information

How To Read A Pipe From A Sensor

How To Read A Pipe From A Sensor Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing

More information

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions. McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes

More information

3/2-way pneumatic cartridge solenoid valve

3/2-way pneumatic cartridge solenoid valve 3/2-way pneumatic cartridge solenoid valve Compact design with 11 mm width per station Orifices from 0.5 mm (9 bar) to 1.2 mm (1.5 bar) High durability and reliability Low power consumption, as well as

More information

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted U/ / & / valves, solenoid and pilot actuated ISO 99-, ISO size,, & Sub-base mounted Steel reinforced main seals 6 bar and bar NOO solenoid pilots with locking or non-locking manual override Low power coils

More information

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions 4057250/8 IM-P405-16 AB Issue 8 ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation 4 Operation

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER... FUEL FILTER............................ FUEL HEATER.......................... INJECTOR.............................. SUPPLY PUMP.......................... COMMON RAIL.......................... FUEL PRESSURE

More information

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY PRODUCT SPECIFICATION SHEET switched off. This results in energy savings during mild weather. Normal control will resume when T3 fails to

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow 1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control

More information

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2 R Extended Range Inductive Prox Greater Sensing Distance Offers Greater Design Flexibility H Sensing distances approximately 1.5 to 2 times larger than that of any conventional Sensor H Reduces problems

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html

http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html TECHNICAL SERVICE DEPARTMENT Removal, Cleaning, & Reinstallation of the Burner Assembly For models 74 & GT199 Required tools -

More information

D2QW D2QW-@@@@@- @ - @ 1 2 3 4 5 6 7. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

D2QW D2QW-@@@@@- @ - @ 1 2 3 4 5 6 7. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions. Extra-long stroke even without levers. (:.7 mm) Clip contacts with highly reliable slide contact

More information