Formtracer SV-C3200 / SV-C4500 SERIES 525 Surface Roughness / Contour Measuring System
|
|
|
- Jemima Davidson
- 9 years ago
- Views:
Transcription
1 Formtracer SV-C3200 / SV-C4500 SERIES 525 Surface Roughness / Contour Measuring System FETURES (X axis: 3. /s (80/s), Z2 axis column:.2 /s (30/s) further reduces total measurement time. specification for an extended period of time, Mitutoyo has adopted highly rigid ceramic guides that combine the characteristics of smallest secular change and remarkable resistance to abrasion. axis) are equipped with a high-accuracy linear encoder (BS type on Z2-axis). This improves reproducibility of continuous automatic measurement of small holes in the vertical direction and repeated measurement of parts which are difficult to position. utomatic Measurement available to support quick and easy CNC operation. Y-axis Table Rotary Table q2 Rotary Table q J-4 SV-C3200S4 with personal computer system and software Surface Roughness Measurement (±( L) µm*) Designed to handle workpieces calling for high accuracy. *S4, H4, W4 types, L = Drive length inch () DIN, VD, and other international surface roughness standards. with a standard high accuracy detector (0.75mN/4mN measuring force) providing a resolution down to 0.004µin (0.000µm). Contour Drive Measurement (±( L)µm*) Z-axis accuracy: ± ( H )µin (±(0.8+I2HI/00)µm*) Designed to handle workpieces calling for high accuracy. * SV-C4500S4, H4, W4 types, L = Drive length, H = Measurement height inch () instruments can continuously measure in the upward and downward directions without the need to change the arm orientation or reset the workpiece, when combined with the double cone-end stylus (a new product with contact points in the upward and downward directions). Technical Data: Coon Base size (W x H): Base material: Mass Main unit: 23.6 x 7.7" (600 x 450) or 39.4 x 7.7" (000 x 450) Granite 308 lbs (40kg) (S4), 330 lbs (50kg) (H4), 485 lbs (220kg) (W4) 308 lbs (40kg) (S8), 330 lbs (50kg) (H8), 485 lbs (220kg) (W8) 3 lbs (4kg) Controller Unit: Remote Control Box: 2 lbs (0.9kg) Power supply: VC ±0%, 50/60Hz Power consumption: 400W (main unit only) Technical Data: Contour Measurement X-axis Measuring range: 4" (00) or 8" (200) Resolution:.97µin (0.05µm) Measurement method: Reflective-type linear encoder Drive speed: 3."/s (80/s) and manual Measuring speed: "/s (0.02-5/s) Measuring direction: Forward/backward Traverse linearity: 32µin/4"(0.8µm/00) 79µin/8 (2µm/200) *with the X axis in horizontal orientation Linear displacement: ±(32+0L)µin (± L) µm (SV-C3200S4, H4, W4) accuracy (at 20 C) ±(32+0L)µin (± L)µm (SV-C4500S4, H4, W4) ±(32+20L)µin (± L)µm (SV-C3200S8, H8, W8) ±(32+20L)µin (± L)µm SV-C4500S8, H8, W8) * L = Drive length inch () Inclination range: ±45 Z2-axis (column) Vertical travel: 2"(300) or 20"(500) Resolution: 39.4µin (µm) Measurement method: BSOLUTE linear encoder Drive speed: 0 -.2"/s (0-30/s) and manual Z-axis (detector unit) Measuring range: ±.2 (±30) Resolution:.57µin (0.04µm) (SV-C3200 series),.78µin (0.02µm) (SV-C4500 series) Measurement method: Linear encoder (SV-C3200 series), Laser hologage (SV-C4500 series) Linear displacement: ±( H) µin (±(.6+ 2H /00)µm) (SV-C3200 series) accuracy (at 20 C) ±( H ) µin (±(0.8+ 2H /00)µm) (SV-C4500 series) *H: Measurement height from the horizontal position () Stylus up/down operation: rc movement Face of stylus: Upward/downward (SV-C3200) Upward/downward (Direction switch by Formtracepak) (SV-C4500) Measuring force: 30mN (SV-C3200) 0, 20, 30, 40, 50mN (SV-C4500) * s for SV-C4500, set the measurement force with Formtracepak. Traceable angle: scent: 77, descent: 83 (using the standard stylus provided and depending on the surface roughness) Stylus tip Radius: 25µm, carbide tip Technical Data: Surface Roughness Measurement X-axis Measuring range: 4" (00) or 8" (200) Resolution:.97µin (0.05µm) Measurement method: Linear encoder Drive speed: 3."/s (80/s) Traversing direction: Backward Traverse linearity: (2+L) µin (0.05+L/000)µm (S4, H4, W4 types) 20µin/8"(0.5µm/200) (S8, H8, W8 types) Z2-axis (column) Vertical travel: 2" (300) or 20" (500) Resolution: 39.4 µin (µm) Measurement method: BSOLUTE linear encoder Drive speed: 0 -.2"/s (0-30/s) and manual Detector Range / resolution: µin /.4 µin, 3200µin /.04µin, 320 µin /.004µin (up to µin with an optional stylus) {800µm / 0.0µm, 80µm / 0.00µm, 8µm / 0.000µm (up to 2400µm with an optional stylus)} Detecting method: Skidless / skid measurement Measuring force: Stylus tip: 0.75mN (low force type) Diamond 60º/2µmR (low force type) Skid radius of curvature:.57" (40) Detecting method: Differential inductance
2 Formtracer SV-C3200 / SV-C4500 SERIES 525 Surface Roughness / Contour Measuring System Optional Software FORMTRCEPK V5 Enables control of the optional motor-driven Y-axis table and rotary table for realizing efficient measurement automation. You can also perform contour evaluation that allows free analysis of level differences, angle, pitch, area and other characteristics based on surface roughness data. In addition, analysis results can be saved in the html, mhtml or pdf format which allows Internet Explorer or MS-Word compatibility, allowing PC without layout editing programs to view analysis results. SPECIFICTIONS Model No. SV-C3200S4 SV-C3200H4 SV-C3200W4 Order No. (inch) Model No. SV-C4500S4 SV-C4500H4 SV-C4500W4 Order No. (inch) X-axis measuring range 4" (00) 4" (00) 4" (00) Measuring force of detector 0.75mN 0.75mN 0.75mN Vertical travel 2" (300) power column 20" (500) power column 20" (500) power column Granite base size (WxD) 23.6 x 7.7" (600 x 450) 23.6 x 7.7" (600 x 450) 39.4 x 7.7" (000 x 450) Dimensions (main unit, WxDxH) 39.2 x 22.6 x 38.0" (996 x 575 x 966) 39.2 x 22.6 x 46.3" (996 x 575 x 76) 55.4 x 22.6 x 46.3" (396 x 575 x 76) Mass (main unit) 308 lbs (40kg) 330 lbs (50kg) 485 lbs (220kg) Model No. SV-C3200S8 SV-C3200H8 SV-C3200W8 Order No. (inch) Model No. SV-C4500S8 SV-C4500H8 SV-C4500W8 Order No. (inch) X-axis measuring range 8" (200) 8" (200) 8" (200) Measuring force of detector 0.75mN 0.75mN 0.75mN Vertical travel 2" (300) power column 20" (500) power column 20" (500) power column Granite base size (WxD) 23.6 x 7.7" (600 x 450) 23.6 x 7.7" (600 x 450) 39.4 x 7.7" (000 x 450) Dimensions (main unit, WxDxH) 39.6 x 22.6 x 38.0" (006 x 575 x 966) 39.6 x 22.6 x 46.3" (006 x 575 x 76) 55.4 x 22.6 x 46.3" (406 x 575 x 76) Mass (main unit) 308 lbs (40kg) 330 lbs (50kg) 485 lbs (220kg) variety of models available for measuring requirements SV-C3200S4 / SV-C4500S4 Traverse range: 4 (00) Vertical travel: 2 (300) Base size (W x D): 23.6 x 7.7 (600 x 450) SV-C3200S8 / SV-C4500S8 Traverse range: 8 (200) Vertical travel: 2 (300) Base size (W x D): 23.6 x 7.7 (600 x 450) Contour Measurement Screen SV-C3200H4 / SV-C4500H4 Traverse range: 4 (00) Vertical travel: 20 (500) Base size (W x D): 23.6 x 7.7 (600 x 450) SV-C3200H8 / SV-C4500H8 Traverse range: 8 (200) Vertical travel: 20 (500) Base size (W x D): 23.6 x 7.7 (600 x 450) Surface Roughness Measurement Screen SV-C3200W4 / SV-C4500W4 Traverse range: 4 (00) Vertical travel: 20 (500) Base size (W x D): 39.4 x 7.7 (000 x 450) SV-C3200W8 / SV-C4500W8 Traverse range: 8 (200) Vertical travel: 20 (500) Base size (W x D): 39.4 x 7.7 (000 x 450) J-5
3 Formtracer Extreme SV-C4500CNC SERIES 525 Surface Roughness/Form Measuring Instrument Surface roughness detector FETURES Form Measuring Instrument that allows both measurement of surface roughness and form/contour with one unit /s (200 /s), which permits highspeed positioning that may result in a large increase in the throughput of multipleprofile/multiple-workpiece measurement tasks. α axis, it is possible to perform continuous measurement over horizontal and inclined surfaces by powertilting the detector unit. possible to expand the measuring range for multiple workpieces, etc., through positioning in the Y-axis direction. stylus (a new product with diametrically opposed contact points), the instrument can continuously measure in the upward and downward directions without the need to change the arm orientation or reset the workpiece fixturing. Contour Z-axis detector SV-C4500CNC with recoended machine vibration stand * PC stand not included among five levels (upward and downward) from the data-processing program (Formtracepak). through 2-axis simultaneous control in the X- and Y-axis directions. measurement is replaced with that for surface roughness measurement, or vice versa, it is a simple, one-touch replacement without re-routing of the connecting cables. anti-collision safety device, the detector unit will automatically stop even if its main body collides with a workpiece or fixture. Box. The user can make any movement by selecting the required axis using the two joysticks. The current axis selection is easily identified by the icon on the key top. nalysis section is via USB. Technical Data: Coon Base size (W x H): 3 x 39.4" (800 x 000) Type S 34 x 47.2" (800 x 200) Type H Mass: 529 lbs (240kg) Type S 55 lbs (250kg) Type H Power supply: 00 20VC ±0%, 50/60Hz Power consumption: 500W (main unit only) Technical Data: Contour Measurement X-axis Measuring range: 8" (200) Resolution:.97µin (0.05µm) Measurement method: Reflective-type linear encoder Drive speed: 7.87"/s (200/s) (max., CNC) 0-2"/s (0-50/s) (joystick) Measuring speed: " 0.08"/s (0.02-2/s) Measuring direction: Push/Pull Traverse linearity: 80µin / 8"(2µm/200) *with the X axis in horizontal orientation Linear displacement accuracy (at 20 C): ±(0.8+4L/200)) * L = Drive length () α-axis Inclination angle: -45 to +0 Resolution: Rotating speed: rpm Z2-axis (column) Vertical travel: 2" or 20" (300 or 500) Resolution:.97µin (0.05µm) Measurement method: Reflective-type linear encoder Drive speed: 7.87"/s (200/s) (max., CNC) 0-2."/s (0-50/s) (joystick) Z-axis (detector unit) Measuring range: ±.2" (±30) Resolution:.787µin (0.02µm) Measurement method: Reflective Type detector unit Linear displacement: ccuracy (at 20 C) ±(32+0H)µin (±(0.8+ 2H /00)µm) *H: Measurement height from the horizontal position () w/o α-axis: ±(.5+0H /000)µm Stylus up/down operation: rc movement Face of stylus: Downward Measuring force: 0, 20, 30, 40, 50mN Traceable angle: scent: 70, descent: 70 (using the standard stylus provided and depending on the surface roughness) Stylus tip Radius: 25µm, carbide tip Technical Data: Surface Roughness Measurement X-axis Measuring range: 8" (200) Resolution:.97µin (0.05µm) Measurement method: Reflective-type linear encoder Drive speed: 7.87"/s (200/s) (max., CNC) 0-2"/s (0-50/s) (joystick) Measuring speed: " "/s (0.02-2/s) Traversing direction: Pulling Traverse linearity: 20µin/8" (0.5µm/200) α-axis Inclination angle: -45 to +0 Resolution: Rotating speed: rpm Z2-axis (column) Vertical travel: 2" or 20" (300 or 500) Resolution:.97µin (0.05µm) Measurement method: Reflective-type linear encoder Drive speed: 7.87"/s (200/s) (max., CNC) 0-2"/s (0-50/s) (joystick) Detector (optional) Range / resolution: µin /.4 µin, 3200µin /.04µin, 320 µin /.004µin (up to µin with an optional stylus) {800µm / 0.0µm, 80µm / 0.00µm, 8µm / 0.000µm (up to 2400µm with an optional stylus)} Detecting method: Skidless / skid measurement Measuring force: 0.75mN Stylus tip: 60º/2µmR Skid radius of curvature:.57" (40) Detecting method: Differential inductance J-6
4 Formtracer Extreme SV-C4500CNC SERIES 525 Surface Roughness/Form Measuring Instrument Optional ccessories Machine vibration stand: 2E032 Vibration isolation mechanism: Diaphragm air spring Natural frequency : - 3.5Hz Damping mechanism: Orifice Leveling mechanism: utomatic control with mechanical valves ir supply pressure: Mpa llowable loading capacity: 772 lbs (350kg) Dimensions (W x D x H): 39.4 x 3 x 28. (000 x 895 x 75) Mass: 67 lbs (280kg) Y-axis table unit Measuring range: 8 (200) Minimum reading :.97µin (0.05µm) Scale unit: Reflective-type Linear Encoder Drive speed: 200/s (max., CNC) 0-2"/s (0-50/s) (joystick) Maximum loading capacity: 44 lbs (20kg) Traverse linearity 20µin/8 (0.5µm/200)Surface roughness 80µin/8 (2µm/200) contour Linear displacement accuracy (at 20 C): ± (80+20L)µin {± (2+2L/00) µm}, contour mode L: Dimension between two measured points () Table size: 7.8 x 7.8 (200 x 200) Dimensions (W x D x H): 2.6 x 25.4 x 4. (320 x 646 x 05) Mass: 77 lbs (35kg) SPECIFICTIONS Model No. SV-C4500S CNC SV-C4500H CNC Order No. (00V - 20V) X-axis measuring range 8" (200) 8" (200) Z2-axis vertical travel 2" (300) 20"(500) Y-axis table unit Installed Installed α-axis unit Installed Installed Granite base size (WxD) 29.5 x 23.6"(750 x 600) 29.5 x 23.6"(750 x 600) Dimensions (main unit, WxDxH) 3.5 x 24.4 x 39.4"(800 x 620 x 000) 3.5 x 24.4 x 47.2"(800 x 620 x 200) Mass (main unit) 529 lbs (240kg) 55 lbs (250kg) DIMENSIONS Unit: Optional Software FORMTRCEPK V5 Enables control of the optional motor-driven Y-axis table and rotary table for realizing efficient measurement automation. You can also perform contour evaluation that allows free analysis of level differences, angle, pitch, area and other characteristics based on surface roughness data. In addition, analysis results can be saved in the html, mhtml or pdf format which allows Internet Explorer or MS-Word compatibility, allowing PC without layout editing programs to view analysis results Detector Stand Contour Measurement and Surface Roughness Measurement Screen Report Layout Screen J-7
5 CLMP CLMP CLMP Formtracer CS-3200 SERIES 525 Form Measuring Instruments FETURES X axis: ±(+0.0L)µm Z axis: ±(.5+ 2H /00)µm in a single measurement the Z-axis detector unit of CS-3200S4 has a wide measuring range and high resolution of 5 / 0.08µm to 0.05 / µm. CS-3200S4 with personal computer system and software * PC stand not included. interference between the drive unit and workpiece. The measuring range is shifted to the left by 2.76 (70). Technical Data: Contour Measurement X-axis Measuring range: 4" (00) Resolution:.97µin (0.05µm) Measurement method: Reflective-type linear encoder Drive speed: 0-3."/s (0-80/s) and manual Measuring speed: "/s ( /s) (surface roughness) "/s (0.02-2/s) (contour) Measuring direction: (Push/Pull) Traverse linearity: 8µin/4 (6µin/4 ) [0.2µm/00 (µm/00)] ( ): at the protruded detector position *with the X axis in horizontal orientation Linear displacement accuracy (at 20 C): ± (32+0L)µin {±( L)µm} * L = Drive length () Inclination range: ±45 Z2-axis (column) Vertical travel: 2" (300) Resolution: 39.4µin (µm) Measurement method: BSOLUTE linear encoder Drive speed: "/s (0-20/s) and manual Z-axis (detector unit) Measuring range / resolution: 3µin/.2",.3µin/.02",.03µin/.002" (0.08µm/5, 0.008µm/0.5, µm/0.05) Measurement method: Differential inductance method Linear displacement: ±(60+20H)µin ±(.5+2H/00)µm ccuracy (at 20 C) *H: Measurement height from the horizontal position () Stylus up/down operation: rc movement Face of stylus: Downward Measuring force: 0.75mN Traceable angle: scent: 65, descent: 65 (using the standard stylus provided and depending on the surface roughness) Stylus tip Radius: 2µm, diamond Base size (W x H): 23.6 x 7.7" (600 x 450) Mass: 309 lbs (40kg) (main unit) Power supply: VC ±0%, 50/60Hz Power consumption: 400W (main unit only) Protrusion of Detector Position Normal detector position Unit: specification for an extended period of time, Mitutoyo has adopted highly rigid ceramic guides that combine the characteristics of smallest secular change and remarkable resistance to abrasion. reduces total measurement time. X axis: 80/s, Z2 axis: 20/s the Z-axis detector unit incorporates a safety device (utomatic Stop-On-Collision Mechanism). axis eliminates the need for origin point re-setting conventionally required for every step of repeated measurements over step or multiple sections. efficiently measured using the inclined X-axis drive unit and fine-feed handles on 35 the X and Z2 axes. housed inside the main unit to eliminate any risk of abrasion and guarantee trouble free, high-speed operation. inclined by ±45. This allows CS-3200 to measure an inclined surface quickly When detector is maximally extended (Extended by 70 from normal position) 05 J-8
6 Formtracer CS-3200 SERIES 525 Form Measuring Instruments SPECIFICTIONS Model No. CS-3200S4 Order No. (inch) X-axis measuring range 4" (00) Z2-axis vertical travel 2" (300) Optional Software FORMTRCEPK-6000 Enables control of the optional motor-driven Y-axis table and rotary table for realizing efficient measurement automation. You can also perform contour evaluation that allows free analysis of level differences, angle, pitch, area and other characteristics based on surface roughness data. In addition, you can create an original inspection certificate by setting the print format to suit your particular requirements. Stylus Standard stylus: No. 2D554 Tip radius: 2 µm Tip angle: 60 cone Tip material: Diamond Eccentric stylus: No. 2D558 Tip radius: 2 µm Tip angle: 60 cone Tip material: Diamond (Unit: inch ()) Measuring instrument control For contour/surface roughness measurement Measurable depth:.28 (7) max. For contour/surface roughness measurement Measurable offset length:.60 (5) Contour analysis Cone stylus: No. 2D552 Tip radius: 25 µm Tip angle: 30 cone Tip material: Sapphire Deep Groove stylus: No. 2D560 Tip radius: 2 µm Tip angle: 60 cone Tip material: Diamond Surface roughness analysis For contour measurement Measurable depth:.28 (7) max. For contour/surface roughness measurement Measurable depth:.79 (20) max. Design data creation (CD file import) Small hole stylus: No. 2D556 Tip radius: 2 µm Tip angle: 60 cone Tip material: Diamond 2x-long stylus: No. 2D562 Tip radius: 5 µm Tip angle: 40 cone Tip material: Diamond Contour verification Inspection certificate creation For contour/surface roughness measurement pplicable hole: For contour/surface roughness measurement Measurable depth:.39 (0) max. This machine incorporates a startup system (relocation detection system), which disables operation when an unexpected vibration is applied or the machine is relocated. Be sure to contact your nearest Mitutoyo prior to relocating this machine after initial installation. Measuring lens Measuring ball screw Measuring bearing ring J-9
7 Formtracer Extreme CS-5000CNC / CS-H5000CNC SERIES 525 CNC Form Measuring Instruments Remote box FETURES Measuring Instrument that allows simultaneous measurement of surface roughness and form/contour. of.57 /s (40 /s) and Z2 axis has a maximum drive speed of 7.87 /s (200 / s). This permits high-speed positioning that may result in a large increase in the throughput of multiple-profile / multipleworkpiece measurement tasks. in the X axis and Z axis so that high resolution (X axis: 6.25nm, Z axis: 4nm/8nm) is achieved and batch measurement of form / contour and surface roughness can be made. the Z-axis detector to implement a widerange measurement capability wherein the variation in dynamic measuring force is restricted. CS-5000CNC with personal computer system and software * PC stand not included Wide range detector employing active control technology anti-collision safety device, the detector unit will automatically stop even if its main body collides with a workpiece or fixture. α-axis, it is possible to perform continuous measurement over horizontal and inclined surfaces by powertilting the X axis. possible to expand the measuring range for multiple workpieces, etc., through positioning in the Y-axis direction. Box, the user can make any movement by selecting the required axis using the two joysticks. The current axis selection is easily identified by the icon on the key top. Processing / nalysis Unit (optional). Technical Data: X axis Measuring range: Resolution: 8 (200) 0.25µin ( µm) Measurement method: Laser Holoscale Drive speed: Measuring speed: Measuring direction: Push / Pull Traverse linearity: *Traverse linearity: Max..57 /s (40/s) (in CNC mode) /s (0-40/s) (in joystick control mode) /s ( /s) (surface roughness) /s (0.02-2/s) (form/contour) (4+.5L)µin {( L)µm} with standard stylus (8+.5L)µin {( L)µm} with 2X-long stylus (2+3L)µin {( L)}µm with standard stylus (4+.5L)µin {( L)}µm with 2X-long stylus Linear displacement accuracy ±(20 C): ±(2+2L)µin {±( L)µm} *Linear displacement accuracy ±(20 C): ±( L)µin {±(+0.00L)µm} L = Measured length inch () Z axis Measuring range: 7" (2) (with standard stylus) 0.94" (24) (with 2X-long stylus) Resolution: µin (0.004µm) (with standard stylus) 0.32µin (0.008µm) (with 2X-long stylus) *Resolution: 0.03µin (0.0008µm) (with standard stylus) 0.06µin (0.006µm) (with 2X-long stylus) Stylus up/down: rc movement Measurement method: Laser Holoscale Linear displacement accuracy (20 C): ±(2+20H)µin {±(0.3+I0.02HI)µm} *Linear displacement accuracy (20 C): ±(2.8+20H)µin {±(0.07+I0.02HI)µm} H = Measured height inch () Measuring force: 4mN (with standard stylus) Traceable angle: 0.75mN (with 2X-long stylus) 60 for ascent, 60 for descent (Depending on the workpiece surface condition) Radius: 5µm, angle: 40, diamond Stylus tip: (ball stylus) (Radius: 0.25, sapphire) Face of stylus: Downward Z2 axis (column unit) Measuring range: 2" (300) (20" (500) high column type) Resolution:.97µin (0.05µm) Measurement method: Reflective-type linear encoder Drive speed: Max /s (200/s) (in CNC mode) /s (0-50/s) (in joystick control mode) Base size (W x D): 29.5 x 23.6 (750 x 600) Dimension (W x D x H): 3.5 x (800 x 620 x 000) 3.5 x 24.4 x 47.2 (800 x 620 x 200: high column type) Mass: *CS-H5000CNC model in red. 529 lbs (240kg) 55 lbs (250kg): high column type)) J-20
8 Formtracer Extreme CS-5000CNC / CS-H5000CNC SERIES 525 CNC Form Measuring Instruments Optional Software FORMTRCEPK V5 Enables control of the optional motor-driven Y-axis table and rotary table for realizing efficient measurement automation. You can also perform contour evaluation that allows free analysis of level differences, angle, pitch, area and other characteristics based on surface roughness data. In addition, analysis results can be saved in the html, mhtml or pdf format which allows Internet Explorer or MS-Word compatibility, allowing PC without layout editing programs to view analysis results. Contour Measurement and Surface Roughness Measurement Screen SPECIFICTIONS Model No. CS-5000CNC CS-5000CNC CS-5000CNC CS-5000CNC Order No. (00V - 20V) X-axis measuring range 8" (200) 8" (200) 8" (200) 8" (200) Z2-axis vertical travel 2" (300) 2" (300) 2" (300) 2" (300) Y-axis table unit Installed Installed α-axis unit Installed Installed Model No. CS-5000CNC CS-5000CNC CS-5000CNC CS-5000CNC Order No. (00V - 20V) X-axis measuring range 8" (200) 8" (200) 8" (200) 8" (200) Z2-axis vertical travel 20" (500) 20" (500) 20" (500) 20" (500) Y-axis table unit Installed Installed α-axis unit Installed Installed Report Layout Screen Model No. CS-H5000CNC CS-H5000CNC Order No. (00V - 20V) X-axis measuring range 8" (200) 8" (200) Z2-axis vertical travel 2" (300) 2" (300) Y-axis table unit Installed SLPK spherical lens analysis program Recoended to be used with CS-H5000CNC and CS- 5000CNC models. To make full use of software functions, optional accessories such as y-axis table, 3DLT and theta q- table are required. The functions can be restricted without the optional accessories. Stylus 2D543* : Standard-length stylus (tip radius: 5µm) 2J037* 2 : For CS-H5000CNC (tip radius: 5µm) Tip material: Diamond 25 40º ø0.5 ball (9) 40º (6.5) 2D544* * 2 : Standard-length ball stylus (tip radius: 5µm) Tip material: Sapphire 07 (6.8) (3.5) (3.5) 2D545* : Double-length stylus (tip radius: 5µm) 2J039* 2 : For CS-H5000CNC (tip radius: 5µm) Tip material: Diamond 2D546* * 2 : Double-length ball stylus Tip material: Sapphire (3.5) (3.5) ø 40º 40º Nosepiece (.) (.) (6.5) (3.5) (3.5) Detector 2D65: Standard-length stylus for small hole Tip radius: 5µm Tip material: Diamond 2D652: Standard-length stylus for extra-small hole Tip radius: 5µm Tip material: Diamond 2D653: Standard-length eccentric stylus Tip radius: 5µm Tip material: Diamond Unit: (3.5) 25 ø0.5 ball (9.3) J04* 2 : Double-length stylus (tip radius: 2µm) Tip material: Diamond (3.5) *: Standard accessory of CS-5000CNC *2: Standard accessory of CS-H5000CNC 25 60º (9) J-2
9 Optional Styli for Surface Roughness Measurement Compatible with SJ-40, SJ-500, SV-200, SV-300, SV-3000CNC, SV-M3000CNC, SV-C3200, SV-C4500 Series Detector (0.75mN): Detector (4mN): ø7 4 Skid nosepiece 2B355 ø8 Detector Extension rods (2G202: 50, 2G203: 00) Styli Unit: Standard stylus Detail E882 (µm)* 2E924 (µm)** 2C73 (2µm)* 2B33 (2µm)** 2B403 (5µm)** 2B45 (0µm)** 2E883 (250µm) 2X long for deep hole E898 (2µm)* 2E94 (5µm)** For small hole.6 Detail- (S=5/) ø C732 (2µm)* 2B404 (5µm)** 2B46 (0µm)** For small hole/2x long for deep hole ø Detail E892 (2µm)* 2E908 (5µm)** For extra small hole.2 Detail- (S=5/) ø ø C733 (2µm)* 2B405 (5µm)** 2B47 (0µm)** For small hole*2 Ball ø E884 (0.8) For extra minute hole 0.8 Detail- (S=5/) ø ø C734 (2µm)* 2B406 (5µm)** 2B48 (0µm)** For ultra small hole **2 Ball ø0.5 7 ø0.3 Detail J662 (0.25) For deep hole (2X long and 3X long) Detail Detail For small slotted hole.6 ø ø0.3 Detail X stylus 2C740 (2µm)* 2B43 (5µm)** 2B425 (0µm)** 3X stylus 2C74 (2µm)* 2B44 (5µm)** 2B426 (0µm)** *: For downward-facing measurment only *2: Used for calibration, a standard step gauge (No.78-6, option) is also required. Tip radius µm 2µm 5µm 0µm 250µm White Black No color Yellow No notch or color 2E938 (2µm)* 2E940 (5µm)** J-22
10 Optional Styli for Surface Roughness Measurement Compatible with SJ-40, SJ-500, SV-200, SV-3200, SV-3000CNC, SV-M3000CNC, SV-C3200, SV-C4500 Series For deep goove (0) Detail C735 (2µm)* 2B409 (5µm)** 2B42 (0µm)** Styli For deep groove (20) * /2X Long for deep hole n.2 9 Unit: 2E893 (2µm)* 2E909 (5µm)** For deep groove (20) For deep groove (40) * Detail C736 (2µm)* 2B408 (5µm)** 2B420 (0µm)** Ø.2 Ø2.4 2E895 (2µm)* 2E9 (5µm)** For deep groove (30) Detail C737 (2µm)* 2B335 (2µm)** 2B407 (5µm)** 2B49 (0µm)** For deep groove (30) * /2X Long for deep hole Ø E894 (2µm)* 2E90 (5µm)** For gear tooth Detail B339 (2µm)* 2B40 (5µm)** 2B422 (0µm)** For gear tooth * /2X Long for deep hole ø3 2E896 (2µm)* 2E92 (5µm)** For rolling circle waviness surface * Ball ø.588 2B338 (0.8) For rolling circle waviness * /2X Long for deep hole * E886 (0.25) For knife-edge detector Detail C738 (2µm)* 2B4 (5µm)** 2B423 (0µm)** For corner hole * /2X Long for deep hole ø ø.6 2M60 (2µm)* 2M603 (5µm)** For eccentric arm * C739 (2µm)* 2B42 (5µm)** 2B424 (0µm)** For bottom surface ø 25 2E899 (2µm)* 2E95 (5µm)** Detail- J-23
11 Optional ccessories for utomatic Measurement Compatible with SV-3200, SV-C3200, SV-C4500, CS-3200 and CNC Models Examples of optimal combinations of accessories for CNC models Optional accessory Y-axis Table q Table q2 Table Y-axis table*: Enables efficient, automatic measurement of multiple aligned workpieces and multiple points on a single measurement surface. * only for SV/CV/SV-C, CS model (non CNC model). Travel range Resolution Positioning accuracy Drive speed Maximum load Mass 8 (200).97µin (0.05µm) ±3µm Max. 3.5 /s (80/s) 0 lbs (50kg) 62 lbs (28kg) q2-axis table: * You can measure multiple points on a cylindrical workpiece and automate front/rear-side measurement. * q2-axis mounting plate (2E78) is required when directly installing on the base of the SV-300. q-axis table: 2D975* For efficient measurement in the axial/transverse directions. When measuring a cylindrical workpiece, automatic alignment can be performed in combination with the Y-axis table. * q-axis mounting plate (2E630) is required when directly installing on the base of the SV-300. Displacement 360 Resolution Maximum load 26.5 lbs (2kg) Rotational speed Max. 0 /s Mass 5 lbs (7kg) uto-leveling table: This is a stage that performs fully automatic leveling as measurement starts, freeing the user from this troublesome operation. Fully automatic leveling can be done quickly by anyone. In addition, the operation is easy and reliable. Function utomatic leveling utomatic alignment (Patent registered: Japan) l l Multiple workpiece batch measurement s Measurement in the Y-axis direction l Oblique measurement of XY plane ** l Outside 3D surface roughness measurement/evaluation ** l Multiple-piece measurement in the Y-axis direction (Positioning in the Y-axis l direction) Multiple-piece measurement in the radius direction (Positioning in the rotating s l direction of XY plane) Tracking measurement in the Z-axis direction * Inclined surface measurement in the X-axis direction s Inclined hole inside measurement in the X-axis s direction Multiple cylinder generatrix line measurement s l Measurement of both top and bottom surfaces s l Rotary positioning of large workpiece *** Upward/downward and frontward/backward measurement of large workpiece *** * : pplicable only to form/contour measurement ** : pplicable only to surface roughness measurement *** : pplicable only for SV-M3000CNC Displacement 360 Resolution Maximum load (loading moment) 8.8 lbs (4kg) Rotational speed Max. 8 /s Mass lbs (5kg) Quick chuck: This chuck is useful when measuring small workpieces. You can easily clamp them with its knurled ring. Inclination adjustment angle ±2 Maximum load 5 lbs (7kg) Table dimensions 5. x 3.9 (30 x 00) Mass 7.7 lbs (3.5kg) Micro-chuck: 2-03 This chuck is suitable for clamping extra-small retained with the centering chuck. Retention range Dimensions Mass Inner latch Inner latch Outer latch 2.6 lbs (.2kg) Retention range Dimensions Mass.3 lbs (kg) J-24
12 Drive unit tilting function (Patent pending: Japan) Large q Table Rotary-type detector holder Optional ccessories for Surftest / Formtracer Compatible with Desktop Models of Surftest and Formtracer l s s 3-axis adjustment table This table helps make the alignment adjustments required when measuring cylindrical surfaces. The corrections for the pitch angle and the swivel angle are determined from a preliminary measurement and the Digimatic micrometers are adjusted accordingly. flat-surfaced workpiece can also be leveled with this table (V-block not included) l l Leveling table (), (inch) x 00 Digital leveling table () (inch) x 00 Leveling table x 00 Calibration stand * 2M00 Calibration stand *2 2G75 Calibration stand *3 2M309 l l l: Essential s: Better to provide with : Not necessary V-block to 60 leveling table Precision vise leveling table. Cross-travel table (), 28-0 (inch) x 80 x 50 Cross-travel table (), (inch) x 52 x Rotary vise type. reading: Center support dia.: 20 optional Center support riser center support. dia.: 240 Swivel center support dia.: 80* * 65 when swiveled 0 length: 40 Holder with clamp cross-travel table or rugged table. height: 35 *: Required for calibrating upward measurement of CV-3200 series. *2: Required for calibrating in bulk by mounting straight arm/small-hole stylus arm without using cross-travel table and Y-axis table. *3: Required for calibrating in bulk by mounting straight arm/eccentric arm/small-hole stylus arm without using cross-travel table and Y-axis table. V-block with clamp , cross-travel table or rugged table. dia.: 50 (72-234), 25 (72-378) J-25
13 Quick Guide to Precision Measuring Instruments Surftest (Surface Roughness Testers) JIS B 060: 200 Geometric Product Specifications (GPS) Surface Texture: Profile method Terms, definitions, and surface texture parameters JIS B 0632: 200 Geometric Product Specifications (GPS) Surface Texture: Profile method Metrological characterization of phase-correct filters JIS B 0633: 200 Geometric Product Specifications (GPS) Surface Texture: Profile method Rules and procedures for the assessment of surface texture JIS B 065: 200 Geometric Product Specifications (GPS) Surface Texture: Profile method Nominal characteristics of contact (stylus) instruments Nominal Characteristics of Contact (Stylus) Instruments Workpiece surface Probe Stylus tip Measurement profile Transducer Z-axis Signal Transfer Unit mplifier D converter Input/Output Quantized measurement profile Nominal texture suppression Profile filter JIS B 065: 200 (ISO 3274: 996) Input/Output Primary profile Parameter evaluation according to JIS B 060 Definition of Parameters mplitude Parameters (peak and valley) Maximum peak height of the primary profile Pp Maximum peak height of the roughness profile Rp Maximum peak height of the waviness profile Wp Largest profile peak height Zp within a sampling length JIS B 060 : 200 (ISO 4287 : 997) Measurement loop Reference guide skid Reference line Rp Column ppearance Feed device Feed device Measuring loop Drive Unit Stylus Shape typical shape for a stylus end is conical with a spherical tip. Tip radius: rtip = 2 µm, 5 µm or 0 µm Taper angle of cone: 60, 90 In typical surface roughness testers, the taper angle of the stylus end is 60 unless otherwise specified R2µm R2µm Static Measuring Force Nominal radius of curvature of stylus tip: µm Note : The maximum value of static measuring force at the average position of a stylus is to be 4.0mN for a special structured probe including a replaceable stylus. Metrological Characterization of Phase Correct Filters profile filter is a phase-correct filter without phase delay (cause of profile distortion dependent on wavelength). The weight function of a phase-correct filter shows a normal (Gaussian) distribution in which the amplitude transmission is 50% at the cutoff wavelength. Data Processing Flow Surface profile on the real surface Measured profile Quantized profile Low-pass filter of cutoff value ls Measurement D conversion R5µm R5µm Static measuring force at the mean position of stylus: mn (4.0) Note R0µm R0µm Tolerance on static measuring force variations: mn/µm JIS B 0632: 200 (ISO 562: 996) Definition: Profile that results from the intersection of the real surface and a plane rectangular to it. Definition: Locus of the center of the stylus tip that traces the workpiece surface. Definition: Data obtained by quantizing the measured profile. Suppresses irrelevant geometry of the surface such as inclination of a flat feature and curvature of a cylindrical feature using the least squares method. lc Workpiece Fixture ls µm Probe (pickup) Stylus Relationship between Cutoff Value and Stylus Tip Radius The following table lists the relationship between the roughness profile cutoff value lc, stylus tip radius rtip, and cutoff ratio lc/ls lc/ls Surface Profiles mplitude transmission % Maximum rtip µm Note 2 Note Note 2 Base Maximum sampling length µm Note : For a surface with Ra>0.5µm or Rz>3µm, a significant error will not usually occur in a measurement even if rtip= 5µm. Note 2: If a cutoff value ls is µm or 8µm, attenuation of the signal due to the mechanical filtering effect of a stylus with the recoended tip radius appears outside the roughness profile pass band. Therefore, a small error in stylus tip radius or shape does not affect parameter values calculated from measurements. If a specific cutoff ratio is required, the ratio must be defined Roughness profile 2 2 Waviness profile JIS B 060: 200 (ISO 4287: 997) Primary profile ls lc lf Wavelength Primary Profile Profile obtained from the measured profile by applying a low-pass filter with cutoff value ls. Roughness Profile Profile obtained from the primary profile by suppressing the longer wavelength components using a high-pass filter of cutoff value lc. Sampling length Maximum valley depth of the primary profile Pv Maximum valley depth of the roughness profile Rv Maximum valley depth of the waviness profile Wv Largest profile valley depth Zv within a sampling length Rv Sampling length Maximum height of the primary profile Pz Maximum height of the roughness profile Rz Maximum height of the waviness profile Wz Sum of height of the largest profile peak height Zp and the largest profile valley depth Zv within a sampling length Rz Rv Sampling length In Old JIS and ISO 4287-: 984, Rz was used to indicate the ten point height of irregularities. Care must be taken because differences between results obtained according to the existing and old standards are not always negligibly small. (Be sure to check whether the drawing instructions conform to existing or old standards.) Mean height of the primary profile elements Pc Mean height of the roughness profile elements Rc Mean height of the waviness profile elements Wc Mean value of the profile element heights Zt within a sampling length m Pc, Rc, Wc = Zt m i Zt Zt2 Zt3 Zt4 i= Sampling length Zt5 Rp Zt6 Primary profile High-pass filter of cutoff value lc Primary profile parameters Band-pass filter that passes wavelengths between cutoff values lc and lf Waviness Profile Profile obtained by applying a band-pass filter to the primary profile to remove the longer wavelengths above lf and the shorter wavelengths below lc. Total height of the primary profile Pt Total height of the roughness profile Rt Total height of the waviness profile Wt Sum of the height of the largest profile peak height Zp and the largest profile valley depth Zv within the evaluation length Roughness profile Waviness profile Rz Rt Rz Rz Roughness profile parameters Waviness profile parameters Sampling length Evaluation length J-26
14 mplitude Parameters (average of ordinates) rithmetical mean deviation of the primary profile Pa rithmetical mean deviation of the roughness profile Ra rithmetical mean deviation of the waviness profile Wa rithmetic mean of the absolute ordinate values Z(x) within a sampling length Pa, Ra, Wa = Z(x) dx l PSm, RSm, WSm = m l 0 with l as lp, lr, or lw according to the case. Root mean square deviation of the primary profile Pq Root mean square deviation of the roughness profile Rq Root mean square deviation of the waviness profile Wq Root mean square value of the ordinate values Z(x) within a sampling length with l as lp, lr, or lw according to the case. Skewness of the primary profile Psk Skewness of the roughness profile Rsk Skewness of the waviness profile Wsk Quotient of the mean cube value of the ordinate values Z(x) and the cube of Pq, Rq, or Wq respectively, within a sampling length The above equation defines Rsk. Psk and Wsk are defined in a similar manner. Psk, Rsk, and Wsk are measures of the asyetry of the probability density function of the ordinate values. Kurtosis of the primary profile Pku Kurtosis of the roughness profile Rku Kurtosis of the waviness profile Wku Quotient of the mean quartic value of the ordinate values Z(x) and the fourth power of Pq, Rq, or Wq respectively, within a sampling length The above equation defines Rku. Pku and Wku are defined in a similar manner. Pku, Rku, and Wku are measures of the sharpness of the probability density function of the ordinate values. Spacing Parameters Mean width of the primary profile elements PSm Mean width of the roughness profile elements RSm Mean width of the waviness profile elements WSm Mean value of the profile element widths Xs within a sampling length Pq, Rq, Wq = Rsk = Rq 3 lr Rku = Rq 4 lr Z 2 (x)dx l lr 0 lr 0 Xs Xs2 Xs3 Xs4 Xs5 Xs6 l 0 Z 3 (x)dx Z 4 (x)dx m i= X Si Curves, Probability Density Function, and Related Parameters Material ratio curve of the profile (bbott-firestone curve) Curve representing the material ratio of the profile as a function of section level c given level c to the evaluation length Pmr(c), Rmr(c), Wmr(c) = Ml(c) ln Rz JIS = Mean Line c Sampling length Rmr(c),% Material ratio of the primary profile Pmr(c) Material ratio of the roughness profile Rmr(c) Material ratio of the waviness profile Wmr(c) Ratio of the material length of the profile elements Ml(c) at a Section height difference of the primary profile Pdc Section height difference of the roughness profile Rdc Section height difference of the waviness profile Wdc Vertical distance between two section levels of a given material ratio Rδc Rδc = c(rmr) c(rmr2); Rmr<Rmr2 c0 c Rmr0 Rmr Relative material ratio of the primary profile Pmr Relative material ratio of the roughness profile Rmr Relative material ratio of the waviness profile Wmr Material ratio determined at a profile section level Rδc (or Pδc or Wδc), related to the reference section level c0 Pmr, Rmr, Wmr = Pmr(c), Rmr(c), Wmr(c) where c = c0 Rδc(Rδc, Wδc) c0 = c(pm0, Rmr0, Wmr0) Probability density function (profile height amplitude distribution curve) Sample probability density function of the ordinate Z(x) within the evaluation length Evaluation length Mean line mplitude density JIS Specific Parameters Ten-point height of irregularities, Rz JIS Sum of the absolute mean height of the five highest profile peaks and the absolute mean depth of the five deepest profile valleys, measured from the mean line within the sampling length of a roughness profile. This profile is obtained from the primary profile using a phase-correct band-pass filter with cutoff values of lc and ls. Zp + Zp 2 + Zp 3 + Zp 4 + Zp 5 + Zv + Zv 2 + Zv 3 + Zv 4 + Zv 5 5 Sampling Length for Surface Roughness Parameters JIS B 0633: 200 (ISO 4288: 996) Table : Sampling lengths for aperiodic profile roughness parameters (Ra, Rq, Rsk, Rku, RΔq), material ratio curve, probability density function, and related parameters Ra µm (0.006)<Ra <Ra0. 0. <Ra2 2 <Ra0 0 <Ra80 Table 2: Sampling lengths for aperiodic profile roughness parameters (Rz, Rv, Rp, Rc, Rt) Rz Rzmax µm (0.025)<Rz, Rzmax0. 0. <Rz, Rzmax <Rz, Rzmax0 0 <Rz, Rzmax50 50 <Rz, Rzmax200 ) Rz is used for measurement of Rz, Rv, Rp, Rc, and Rt. 2) Rzlmax only used for measurement of Rzlmax, Rvlmax, Rplmax, and Rclmax. Table 3: Sampling lengths for measurement of periodic roughness profile roughness parameters and periodic or aperiodic profile parameter Rsm Rsm 0.03 <Rsm <Rsm <Rsm <Rsm.3.3 <Rsm4 Procedure for determining a sampling length if it is not specified Estimate Ra, Rz, Rzmax, or RSm according to recorded waveforms, visual inspection, etc. Estimate the sampling length from an estimated value and Tables to 3 Measure Ra, Rz, Rzmax, or RSm according to the estimated value of the sampling length Does each measured value meet the parameter range of Table, 2, or 3? Yes Has a shorter sampling length been tried? Yes Measure the parameter according to the final sampling length Fig. Procedure for determining the sampling length of an aperiodic profile if it is not specified. Estimate RSm from a measured roughness profile Sampling length lr Sampling length lr Sampling length lr No No Evaluation length ln Evaluation length ln Evaluation length ln Change to a longer or shorter sampling length Change to a shorter sampling length Sampling length Hybrid Parameters Root mean square slope of the primary profile PΔq Root mean square slope of the roughness profile RΔq Root mean square slope of the waviness profile WΔq Root mean square value of the ordinate slopes dz/dx within a sampling length dz (x) dx dz (x) dx dz (x) dx dz (x) dx dz (x) dx Zp 3 Symbol RzJIS82 RzJIS94 Zv 3 Zv Zv 2 Used profile Ra 75 = ln Zp 2 0 Zv 5 Z(x) dx Zp 4 Zp 5 Sampling length Surface profile as measured Zv 4 Zp Roughness profile derived from the primary profile using a phase-correct high-pass filter rithmetic mean deviation of the profile Ra 75 rithmetic mean of the absolute values of the profile deviations from the mean line within the sampling length of the roughness profile (75%). This profile is obtained from a measurement profile using an analog high-pass filter with an attenuation factor of 2db/octave and a cutoff value of lc. ln Estimate the sampling length from an estimated value and Table 3 Measure RSm according to the estimated value of the sampling length Does the measured value meet the condition of Table 3? Yes Measure the parameter according to the final sampling length No Change the sampling length so as to meet the condition of Table 3 Fig.2 Procedure for determining the sampling length of a periodic profile if it is not specified. J-27
CONTRACER CV-3100/4100 Series
Form Measurement Contour Measuring System CONTRACER CV-3100/4100 Series Catalog No. E4293-218 Next-generation manual Contour Measuring Machine delivers high accuracy, high drive speed and simplified CNC
CNC FORM MEASURING INSTRUMENT SERIES
Form Measurement CNC FORM MESURING INSTRUMENT SERIES Catalog No. E4284 The world s leading range of CNC Form Measuring Machines ushers in a new age of automated measurement. Simply switching to the dedicated
Form Measurement. Surface Roughness Measuring Instruments Surftest Pages 530 to 539
Form Measurement Surface Roughness Instruments Pages 530 to 539 529 SJ-210 Series 178 - SJ-210 The SJ-210 is a user-friendly surface roughness measurement instrument designed as a handheld tool that can
A guide to Surface Texture Parameters
www.taylor-hobson.com Taylor Hobson SA 6 avenue de Norvège, Hightec 4 91953 Courtaboeuf Cedex, France Tel: +33 160 92 14 14 Fax: +33 160 92 10 20 e-mail: [email protected] Taylor Hobson Germany
Industrial Metrology from Carl Zeiss. Contour and Surface Measuring Machines
Industrial Metrology from Carl Zeiss Contour and Surface Measuring Machines Overview Inspection equipment from Carl Zeiss for the production floor. Carl Zeiss offers a complete product line for industrial
Good Practice Guide No. 37. The Measurement of Surface Texture using Stylus Instruments. Richard K Leach. Issue 2
Good Practice Guide No. 37 The Measurement of Surface Texture using Stylus Instruments Richard K Leach Issue 2 Measurement Good Practice Guide No. 37 The Measurement of Surface Texture using Stylus Instruments
Perthometer. Surface Texture Parameters New Standards DIN EN ISO / ASME
Perthometer. Surface Texture Parameters New Standards DIN EN ISO / ASME MAHR GMBH, Germany - EDITION 09/01/99 Contents Real surface... Geometrical Product Specification Definition Profile filter P t Profile
SURFTEST SJ-410 Series
Form Measurement Portable Surface Roughness Tester SURFTEST SJ-410 Series Bulletin No. 2080 Portable surface roughness tester evolution Rich choice of options provide easier, smoother and more accurate
Surface Roughness Testing
Surface Roughness Testing M-1 Roughness Parameters Commonly Used in Short Mean roughness Ra (ISO 4287, DIN 4768) The mean roughness Ra matches the arithmetical mean of the absolute values related to the
Profile Projector PH-3500
Optical Measuring Profile Projector PH-3500 Catalog No. E4155-172 Mitutoyo introduces the PH-3515F a series of profile projectors that will meet any optical measuring or inspection challenge your shop
SJ-201P/M PORTABLE SURFACE ROUGHNESS TESTER
CATALOG No. E4152-178 PORTABLE SURFACE ROUGHNESS TESTER Smart tool in the workshop PORTABLE SURFACE ROUGHNESS TESTER Large characters are displayed on the large easy-to-view LCD. Portable for easy measurement
ENGINEERING METROLOGY
ENGINEERING METROLOGY ACADEMIC YEAR 92-93, SEMESTER ONE COORDINATE MEASURING MACHINES OPTICAL MEASUREMENT SYSTEMS; DEPARTMENT OF MECHANICAL ENGINEERING ISFAHAN UNIVERSITY OF TECHNOLOGY Coordinate Measuring
DMS 680. Universal length measuring system gauge inspection for»iso 9000«requirements
DMS 680 Universal length measuring system gauge inspection for»iso 9000«requirements Universal length measuring system DMS 680 Wide range of applications For periodic inspection of gauges, reference gauges,
Length, Finland, MIKES (VTT Technical Research Centre of Finland Ltd, Centre for Metrology / Mittatekniikan keskus)
absolute mise en pratigue: mise en pratigue: absolute absolute Level or Range 633 633 nm 0.04 fm 2 95% No 1 474 474 THz 24 khz 2 95% No 1 532 532 nm 0.08 fm 2 95% No 50 563 563 THz 0.08 MHz 2 95% No 51
Surface Finish and Contour Measurement
Section Content T500 Turbo Datawin T1000 Basic T1000 Wave W55 Wavespeed 1010 T8000 Contour T8000 Surface Finish T8000 Surfscan Portable Surface Finish Measurement 48 Surface Finish Evaluation Software
5-Axis Test-Piece Influence of Machining Position
5-Axis Test-Piece Influence of Machining Position Michael Gebhardt, Wolfgang Knapp, Konrad Wegener Institute of Machine Tools and Manufacturing (IWF), Swiss Federal Institute of Technology (ETH), Zurich,
TR Series Surface Roughness Tester for workshop and laboratory
TR Series Surface Roughness Tester for workshop and laboratory Portable, rugged and instant operation on metallic and ceramic surfaces Surface roughness measurement the basics Application Surface roughness
OPTICAL MEASURING MACHINES
OPTICAL MEASURIN MACHINES SYLVAC SCAN Dedicated to the fast and contactless measuring of cylindrical parts, our new SCAN machines are based on the principle of the scanner. This technique allows to reproduce
Surface Texture Measuring Instruments. Compact & Touch operetion type SURFCOM Series
Surface Texture Measuring Instruments Compact & Touch operetion type SURFCOM Series Surface Texture Measuring Instrument Operator-oriented Operation for the Workplace New Surface Texture Measuring Instrument
MANUAL TR-110 TR-110
MANUAL TR-110 TR-110 CONTENTS 1. GENERAL INTRODUCTION 2 2. WORK PRINCIPLE 3 3. STANDARD DELIVERY 4 4. NAME OF EACH PART 5 5. OPERATION 6 5.1 Preparation before operation 6 5.2 Switch on, Switch off and
Mitutoyo General Catalog
Mitutoyo General Catalog Micrometer List of products Move to other products Digimatic Micrometer SERIES 293 Quickmike SERIES 293, 369, 422 Digimatic Micrometers SERIES 293 1 2 SPC Caliper 3 4 Depth gage
A cut above the rest. sprintcut. CNC Wirecut EDM
ZAXS I sprintcut Z AXIS sprintcut 4 axes CNC Precision LM guideways for all axes Max. cutting speed : 2 16 mm / min. (With Ø.25 special soft brass wire on 5 mm thick HCHCr (steel) workpiece) 2 14 mm /
Reaction Torque Sensor
Force 1 1 N m up to 1 000 1 000 N m Type 9329A 9389A These easy to install piezoelectric reaction torque sensors are particularly suitable for measuring rapidly changing torques at non-rotating shafts.
Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Unit 7 Contact: Mr S C Sparks Solent Industrial Estate Tel: +44 (0)1489 790296 Hedge End Fax: +44 (0)1489 790294 Southampton E-Mail: [email protected]
Machine Tool Inspection & Analyzer solutions
Machine Tool Inspection & Analyzer solutions Introduction IBS Precision Engineering machine tool inspection series offers a range of products to provide peace of mind and control to machine operators by
NANO INDENTERS FROM MICRO STAR TECHNOLOGIES
NANO INDENTERS FROM MICRO STAR TECHNOLOGIES Micro Star makes a variety of nano indenters following defined standards or custom requested geometries and dimensions. Micro Star calibration laboratory complies
Form Measurement. Surftest SJ-400. Bulletin No. 2013. Portable Surface Roughness Tester
Form Measurement Surftest SJ-400 Bulletin No. 203 Portable Surface Roughness Tester Surftest SJ-400 Series Revolutionary New Portable Surface Roughness Testers Make Their Debut Long-awaited performance
VICKERS HARDNESS TESTER. HBS HBW Kc
ICKERS HARDNESS TESTER H HK HBS HBW Kc Clean Touch Panel coordinated with highly integrated PC board. Measuring procedures, conditions and data are displayed clearly. (F-800 Series) Accurate light load
Section. Tolerances. Aluminum Extrusion Manual. 4th Edition
Section 8 Tolerances Aluminum Extrusion Manual 4th Edition Section 8 How straight is straight enough? How flat is flat enough? How uniform must a wall thickness be in order to be acceptable? These are
Complete catalogue 2012
Measurement technology - Made in Germany Complete catalogue 2012 4Contour 4Roughness 4Roundness 4Stylus tips 4Accessories 2 Product range overview Content optacom product range overview 2 Content 3 optacom
CATIA Functional Tolerancing & Annotation TABLE OF CONTENTS
TABLE OF CONTENTS Introduction...1 Functional Tolerancing and Annotation...2 Pull-down Menus...3 Insert...3 Functional Tolerancing and Annotation Workbench...4 Bottom Toolbar Changes...5 3D Grid Toolbar...5
SCHMIDT ManualPress 300 Series Manual Presses with Process Monitoring
Manual Presses with Process Monitoring Process reliability, force/stroke monitoring of the joining process and EN ISO- compatible documentation of the results are becoming the major factors for small and
Renishaw 2008. apply innovation TM. Calibrating 5-axis machines to improve part accuracy. 5Align
Calibrating 5-axis machines to improve part accuracy 5Align Productive Process Pyramid TM Understanding and tracking machine behaviour Process verification Thermal compensation In-cycle process control
YUASA MILLING MACHINE ACCESSORIES & TOOLS
97 HORIZONTAL / VERTICAL 5C COLLET INDEX 550 series 2 YEAR WARRANTY Spindle is manufactured with a taper seat in body frame. Rapid opening and closing is performed with a level collet closer with a leverage
Easy Machining Center Setup
White Paper Document No. MWA-072-EN_01_1404 April 2014 Easy Machining Center Setup Using FANUC s Direct Input of Workpiece Origin Setting Measured and Tool Length Measurement features to easily establish
11.1. Objectives. Component Form of a Vector. Component Form of a Vector. Component Form of a Vector. Vectors and the Geometry of Space
11 Vectors and the Geometry of Space 11.1 Vectors in the Plane Copyright Cengage Learning. All rights reserved. Copyright Cengage Learning. All rights reserved. 2 Objectives! Write the component form of
LARGE MEASUREMENT RANGE MECHANICAL COMPARATOR FOR CALIBRATION OF LONG GAUGE BLOCKS
XVII IMEKO World Congress Metrology in the 3rd Millennium June 22 27, 2003, Dubrovnik, Croatia LARGE MEASUREMENT RANGE MECHANICAL COMPARATOR FOR CALIBRATION OF LONG GAUGE BLOCKS Tanfer Yandayan TUBITAK-Ulusal
HF series Hall effect joysticks
Distinctive features and specifications 1, 2 & 3 axis configurations Dual sensors for redundancy CANbus J1939 and CANopen options Voltage regulator, 24V supply option USB 1.1 HID interface option ized
Press Release. Turning/grinding center INDEX C200 Now also horizontal integration of grinding technology
Press Release Turning/grinding center INDEX Now also horizontal integration of grinding technology The is already one of the most successful machine series of INDEX in Esslingen, Germany. Its exceptionally
Series 6000 Torque measured metal bellow coupling
Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement
CNC Machine Control Unit
NC Hardware a NC Hardware CNC Machine Control Unit Servo Drive Control Hydraulic Servo Drive Hydraulic power supply unit Servo valve Servo amplifiers Hydraulic motor Hydraulic Servo Valve Hydraulic Servo
Technical Data. 7. Bearing Fits. 7.1 Interference. 7.2 Calculation of interference F B LLLLLLLLL( A-54
Technical Data 7. Bearing Fits 7.1 Interference For rolling s the rings are fixed on the or in the housing so that slip or movement does not occur between the mated surface during operation or under. This
Metrol. Meas. Syst., Vol. XVII (2010), No. 1, pp. 119-126 METROLOGY AND MEASUREMENT SYSTEMS. Index 330930, ISSN 0860-8229 www.metrology.pg.gda.
Metrol. Meas. Syst., Vol. XVII (21), No. 1, pp. 119-126 METROLOGY AND MEASUREMENT SYSTEMS Index 3393, ISSN 86-8229 www.metrology.pg.gda.pl MODELING PROFILES AFTER VAPOUR BLASTING Paweł Pawlus 1), Rafał
Machine Tool Control. Besides these TNCs, HEIDENHAIN also supplies controls for other areas of application, such as lathes.
Machine Tool Control Contouring controls for milling, drilling, boring machines and machining centers TNC contouring controls from HEIDENHAIN for milling, drilling, boring machines and machining centers
MDM-Metrosoft Guide to GearSoft program Versions 5.06 5.07 5.08. Guide to GearSoft Software Code: 193 Versions 5.06 5.07 5.08
MDM-Metrosoft Guide to GearSoft program Versions 5.06 5.07 5.08 Guide to GearSoft Software Code: 193 Versions 5.06 5.07 5.08 MDM-Metrosoft - Guide to GearSoft program Versions 5.06 5.07 5.08 Page 2 of
Making Better Medical Devices with Multisensor Metrology
Making Better Medical Devices with Multisensor Metrology by Nate J. Rose, Chief Applications Engineer, Optical Gaging Products (OGP) Multisensor metrology is becoming a preferred quality control technology
Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM
Force measurement Forces VECTORIAL ISSUES In classical mechanics, a force is defined as "an action capable of modifying the quantity of movement of a material point". Therefore, a force has the attributes
Equipment Manual. for. Operation of Automatic Polishing Plate Control on the PM5 Precision Lapping & Polishing Machine.
Equipment Manual for Operation of Automatic Polishing Plate Control on the PM5 Precision Lapping & Polishing Machine Ref: BE-01-53-5 PREFACE: PM5 auto-lap/pol MACHINES The PM5 auto-lap/pol features two
DRAFTING MANUAL. Gears (Bevel and Hypoid) Drafting Practice
Page 1 1.0 General This section provides the basis for uniformity in engineering gears drawings and their technical data for gears with intersecting axes (bevel gears), and nonparallel, nonintersecting
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
PBZ Heavy. PBZ Heavy. CNC Gantry-Type Machining Center. Power - Performance - Precision. www.knuth-usa.com
CNC Gantry-Type Machining Center Power - Performance - Precision Travel X-axis up to 244 in Y-axis up to 126 in Z-axis up to 39 in Strong Machine bed, dual columns and fixed bridge ensure a rigid frame
Mercury TM 1500P PCB-Mount Digital Encoders
Mercury TM 1500P PCB-Mount Digital Encoders Factory Set Resolution to 0.50μm Reflective Linear and Rotary Encoders Sensor the size of a Dime Resolution Factory Set: x4, x8, x20, or x40 Linear: 5μm, 2.5μm,
Milling and Machining Center Basics
Training Objectives After watching the video and reviewing this printed material, the viewer will gain knowledge and understanding of basic milling theories and procedures. In addition, the viewer will
Application Report: Running µshape TM on a VF-20 Interferometer
: Running µshape TM on a VF-20 Interferometer General This report describes how a fiber interferometer from Arden Photonics Ltd was used together with the µshape TM Generic software package. The VF-20
RAPID DIAL TEST INDICATORS
RAPID DIAL TEST INDICATORS The Verdict Rapid presents the dial face inclined to the workpiece surface ensuring good visual accessibility obviating parallax error. Rapids incorporate a rear swivel spigot
UNITED STATES CUTTING TOOL INSTITUTE Product Groupings for Standards Activities CUTTING TOOL PRODUCTS
CUTTING TOOL PRODUCTS 1. BORING ISO 5609 Boring bars for indexable inserts Dimensions ISO 6261 Boring bars (tool holders with cylindrical shank) for indexable inserts Designation JIS B 4128 Boring bars
LOCATION DEPENDENCY OF POSITIONING ERROR IN A 3-AXES CNC MILLING MACHINE
th International & 26 th All India Manufacturing Technology, Design and Research Conference (AIMTDR 214) December 12 th 14 th, 214, IIT Guwahati, Assam, India LOCATION DEPENDENCY OF POSITIONING ERROR IN
Description. Dimensions. Features. www.pwb-encoders.com. precision works better
Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature
Fixturing systems Fixturing systems for measurement technology
Fixturing systems Fixturing systems for measurement technology Innovations and new additions to range Sets Spannfix Eco complete set The set contains different supports, extension elements and stop units.
Series 7500 Torque Sensor
Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement
[ means: Save time, money and space! MAXXMILL 500. Vertical milling center for 5-side machining
[ E[M]CONOMY] means: Save time, money and space! MAXXMILL 500 Vertical milling center for 5-side machining MAXXMILL 500 MAXXMILL 500 is the ideal vertical milling center for the for the 5-axis operation
Product Information. QUADRA-CHEK 3000 Evaluation Electronics For Metrological Applications
Product Information QUADRA-CHEK 3000 Evaluation Electronics For Metrological Applications April 2016 QUADRA-CHEK 3000 The evaluation electronics for intuitive 2-D measurement The QUADRA-CHEK 3000 evaluation
Some additional standards and specifications that directly or indirectly affect surface finish requirements include:
Surface Finish Charts Surface Finish Affects Performance The surface finish of process vessels, piping and related components can be a critical factor in their performance, maintenance costs, and service
CALIBRATION OF A ROBUST 2 DOF PATH MONITORING TOOL FOR INDUSTRIAL ROBOTS AND MACHINE TOOLS BASED ON PARALLEL KINEMATICS
CALIBRATION OF A ROBUST 2 DOF PATH MONITORING TOOL FOR INDUSTRIAL ROBOTS AND MACHINE TOOLS BASED ON PARALLEL KINEMATICS E. Batzies 1, M. Kreutzer 1, D. Leucht 2, V. Welker 2, O. Zirn 1 1 Mechatronics Research
Mounting instructions. Acceleration Transducer B12. B 26.B12.10 en
Mounting instructions Acceleration Transducer B12 B 26.B12.10 en B12 3 Contents Page Safety instructions.............................................. 4 1 Scope of supply..............................................
Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors
20000 Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors 23000 22000 21000 20000 09000 08000 07000 06000 05000 04000 03000 02000 01000 823 Notes 824 Technical
TL-Series Sub-Spindle Operator s Addendum
3 4 5 11 9 TL-Series Sub-Spindle Operator s Addendum 2 1 12 10 6 7 8 20HP VECTOR DUAL DRIVE LIVE TOOLING SUB SPINDLE 2008 Haas Automation, Inc. 96-0037 rev L 9/08 1 1. Introduction Specific M codes are
DUGARD. Machine Tools Since 1939. Dugard 700L Series Heavy Duty CNC Lathes. www.dugard.com
DUGARD Machine Tools Since 1939 Dugard 700L Series Heavy Duty CNC Lathes www.dugard.com Dugard 700L Heavy Duty CNC Lathe 2000, 3000 or 4000mm bed length Designed for easy and convenient operation The concave
HOBBING MACHINE TYPE ZFWZ 8000x40
Inventory number 416/635 Year of production 1973 Serial number 7160 HOBBING MACHINE TYPE ZFWZ 8000x40 Application The machine is provided for milling cylindrical, helical and helix cogwheels. The tooth
Small Optical Encoder Modules 480lpi Digital Output. Features. Applications VCC 3 CHANNEL A 2 CHANNEL B 4 GND 1
HEDS-9730, HEDS-9731 Small Optical Encoder Modules 480lpi Digital Output Data Sheet Description The HEDS-973X is a high performance incremental encoder module. When operated in conjunction with either
Advantages and application of PCD and CBn tools
PCD and CBN tools Advantages and application of PCD and CBn tools Powerful and economical Tools with PCD and CBN cutting edges are the ideal solution for difficult-to machine, highly abrasive materials.
Thickness Gauges. convex R 15 or R 40, flat 10 mm Ø, spherical
Thickness Gauges Technical Data for Metric Thickness Gauges Page Model Lifting Contact points Contact points mm mm mm device standard available on request 130 K 15 0.1 10 15 no 6.35 mm Ø flat Ø flat, 130
RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G
Auto-Levelling Rotary Laser Level RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G 77-496 / 77-429 / 77-439 / 77-497 / 77-427/ 77-441 Please read these instructions before operating the product Auto-Levelling
Technical Product Specification (TPS)
ISO Standards collection Technical Product Specification (TPS) Contents ISO 1:2002 Geometrical Product Specifications (GPS) -- Standard reference temperature for geometrical product specification and verification
Determination of source parameters from seismic spectra
Topic Determination of source parameters from seismic spectra Authors Michael Baumbach, and Peter Bormann (formerly GeoForschungsZentrum Potsdam, Telegrafenberg, D-14473 Potsdam, Germany); E-mail: [email protected]
Newland Machine Tool Group Inc.
Newland Machine Tool Group Inc. HEAVY MACHINE TOOLS OVERVIEW Horizontal Boring Mills KB Series T-type HBM with 130 or 165 mm extendable spindle (W-axis), column movable in the spindle direction (Z-axis),
TechCut 4 Precision Low Speed Saw
Product Brochure TechCut 4 Precision Low Speed Saw 3" - 6" Blade Range Digital Speed Display 1-Micron Sample Indexing Spring-Loaded Dressing Stick Attachment All Aluminum & Stainless Steel Construction
CASE HISTORY #2. APPLICATION: Piping Movement Survey using Permalign Laser Measurement System
CASE HISTORY #2 APPLICATION: Piping Movement Survey using Permalign Laser Measurement System EQUIPMENT: Dresser-Clark Hot Gas Expander (Turbine), 60-inch Inlet Flange HISTORY: Piping support modifications
zeus Marking Technology
zeus Marking Technology Marking Tools Marking Rolls Engraving Technology Die Premium-Marke von Hommel+Keller zeus MARKING TECHNOLOGY zeus is a premium brand that stands for highest quality, precision,
MEASURING MACHINES. Pratt & Whitney METROLOGY LABORATORY. Measurement Systems, Inc.
METROLOGY LABORATORY Pratt & Whitney Measurement s, Inc. METROLOGY LABORATORY The Standard of Accuracy Pratt & Whitney Metrology Laboratory Machines are the standard of accuracy to which all other gages
Milling & Machining Centers
Training Objective After watching the program and reviewing this printed material, the viewer will gain knowledge and understanding of basic milling theories and procedures. In addition, the viewer will
GEOMETRY OF SINGLE POINT TURNING TOOLS
GEOMETRY OF SINGLE POINT TURNING TOOLS LEARNING OBJECTIVES Introduction to Features of single point cutting tool. Concept of rake and clearance angle and its importance System of description of Tool geometry
1.1 It is the intention of Van-Rob Inc. to ensure that checking fixture vendors are adhering to this standard.
PROCEDURE # E233 Page 1 of 5 1.0 Purpose: 1.1 It is the intention of Van-Rob Inc. to ensure that checking fixture vendors are adhering to this standard. 1.2 Fixture sources shall refer to this rider for
SCS Directory Accreditation number: SCS 0115
International standard: ISO/IEC 17025:2005 Swiss standard: SN EN ISO/IEC 17025:2005 METRON SA Calibration Laboratory Via Luserte Sud 7 CH-6572 Quartino Head: Angelo Capone Responsible for MS: Angelo Capone
Harmonic oscillations of spiral springs Springs linked in parallel and in series
.3.26 Related topics Spring constant, Hooke s Law, oscillations, limit of elasticity, parallel springs, serial springs, use of an interface. Principle and task The spring constant D is determined for different
FIRERAY 2000 Installation Guide
FIRERAY 2000 Installation Guide Features Range 33ft to 330 ft. 24Vdc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or Automatic reset System Description
ME 24-688 Week 11 Introduction to Dynamic Simulation
The purpose of this introduction to dynamic simulation project is to explorer the dynamic simulation environment of Autodesk Inventor Professional. This environment allows you to perform rigid body dynamic
DENSITY MEASURING SYSTEMS
SHIBAYAMA SCIENTIFIC CO., LTD. DENSITY MEASURING SYSTEMS Density Gradient Tube Method Direct Reading Type A / Type B Comply with the standards below: JIS K-0061-1992, K-7112 1980 ASTM D1505 Type A /Left
Milling Milling milling cutter milling machines 1
Milling Milling is a basic machining process by which a surface is generated progressively by the removal of chips from a workpiece as it is fed to a rotating cutter in a direction perpendicular to the
AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels
AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels AISI No. 1008 1010 1012 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 10 1026 1027 1029 10 1035 1036 1037 1038 1039 10 1041 1042 1043
Section 5.0 : Horn Physics. By Martin J. King, 6/29/08 Copyright 2008 by Martin J. King. All Rights Reserved.
Section 5. : Horn Physics Section 5. : Horn Physics By Martin J. King, 6/29/8 Copyright 28 by Martin J. King. All Rights Reserved. Before discussing the design of a horn loaded loudspeaker system, it is
Roughness measurements of stainless steel surfaces
Roughness measurements of stainless steel surfaces Introduction Surface roughness is a measure of the teture of a surface. It is quantified by the vertical deviations of a real surface from its ideal form.
Weeke CNC Machining Center, Model BHC 550 NB
Weeke CNC Machining Center, Model BHC 550 NB Weeke's BHC-550 NB is a truly industrial machine designed primarily for boring and routing of flat components that have been nested into full sheets of material.
The Bonelle Tool and Cutter Grinder
The Bonelle Tool and Cutter Grinder The grinder was constructed about 1987 and exhibited at the 89th Model Engineering exhibition where it was awarded a bronze medal (see ME Vol164 No 3868 page 273). Subsequently
Introduction to Accuracy and Repeatability in Linear Motion Systems
Introduction to accuracy and repeatability in linear motion systems By Gary Rosengren, Director of Engineering Tolomatic, Inc. About the Author Gary Rosengren is Director of Engineering at Tolomatic and
Copyright 2011 Casa Software Ltd. www.casaxps.com. Centre of Mass
Centre of Mass A central theme in mathematical modelling is that of reducing complex problems to simpler, and hopefully, equivalent problems for which mathematical analysis is possible. The concept of
Measurement Types in Machinery Monitoring
February 2014 Measurement Types in Machinery Monitoring Online machinery monitoring for rotating equipment is typically divided into two categories: 1. Protection Monitoring 2. Prediction Monitoring This
Driven Toolholders for SAUTER Turrets
Driven Toolholders for SAUTER Turrets Manufacturer of Precision Tools since 1974 INNOVATION PRECISION INDIVIDUALITY QUALITY SERVICE Table of Contents Type Page Driven Toolholders DIN 5482 - Disc-type Turrets
SPINDLE ERROR MOVEMENTS MEASUREMENT ALGORITHM AND A NEW METHOD OF RESULTS ANALYSIS 1. INTRODUCTION
Journal of Machine Engineering, Vol. 15, No.1, 2015 machine tool accuracy, metrology, spindle error motions Krzysztof JEMIELNIAK 1* Jaroslaw CHRZANOWSKI 1 SPINDLE ERROR MOVEMENTS MEASUREMENT ALGORITHM
Introduction to CATIA V5
Introduction to CATIA V5 Release 16 (A Hands-On Tutorial Approach) Kirstie Plantenberg University of Detroit Mercy SDC PUBLICATIONS Schroff Development Corporation www.schroff.com www.schroff-europe.com