DENSITY MEASURING SYSTEMS
|
|
|
- Ada Brown
- 9 years ago
- Views:
Transcription
1 SHIBAYAMA SCIENTIFIC CO., LTD. DENSITY MEASURING SYSTEMS Density Gradient Tube Method Direct Reading Type A / Type B Comply with the standards below: JIS K , K ASTM D1505 Type A /Left For measurement of a large number of samples With up to 6 large glass tubes Type B /Right For measurement of a small number of samples With up to 4 small glass tubes FEATURES 1. Density gradient tube method makes density measurements stable and easy. 2. Standard density floats -- the heart of this measurement principle -- are backed by Shibayama's 30 years of experience. 3. Backed by maintenance service -- re-verification of standard density floats and periodic calibration of the main unit (a calibration certificate is issued). 4. Highly accuracy measurement (Group A floats are g/cc calibrated to g/cc) 5. Wide range of sample shapes (films, plates, pellets, etc.) and materials (solid form). APPLICATIONS 1. Density measurements of high molecular weight materials 2. Density measurements of fibers (natural and manmade) 3. Density measurements of resin products 4. Density measurements of products for quality control
2 5 7 JIS K Scale Density g/cc A JIS K mm A B0.001 g/cc g/cc g/cc g/cc g/cc g/cc g/cc g/cc Lotu 5 cm 10 cm 20 cm 4 The standard density floats in the above density gradient tube are shown at 5 cm intervals for explanation purposes. In an actual application, the floats should be located at 10 to 20 cm intervals. Excel Lotus 2
3 ABOUT DENSITY GRADIENT LIQUID A density gradient liquid is composed of continuous layers of liquids of different densities. The lighter density liquids rise to the top layer of the density gradient liquid column, and the heavier density liquids sink to the bottom. the density gradient of the layers between the top and bottom is continuous. Installation and Use of Density Gradient Tubes density gradient tubes filled with the liquid is installed in a constant temperature oven in order to keep the liquid column unchanged over a long period of time. Several standard density floats with even density differences are placed in the tube. Read the scale to show the sample position in reference to the nearest floats. This measuring principle is based on JIS K Methods for Determining the Density and Specific Gravity of Plastics. Preparation of Density Gradient Liquid Density gradient liquid can be prepared by mixing light and heavy density liquids which have affinity. Place heavy liquid at the bottom of the glass. Place layers of mixture with lighter density over the heavier layers until the density difference between the light liquid is canceled. This completes the liquid column with desired density gradient. WHAT ARE STANDARD DENSITY FLOATS? The standard density floats are glass balls 5 mm in diameter. The density is adjusted to g/cc (Group A) of nominal density. When these floats are placed in a cylinder of density gradient solution, the graduated scales of the cylinder corresponding with the position of the floats equals the known densities of the floats. Each float is supplied with a verification certificate showing the test instruments carried out according to JIS K Test Methods for Density and Relative Density of Chemical Products. For details of test, see 'Traceability for Standard density Floats' separately available. Specifications and Accuracy Groups Material: Hard glass Size: Approx. 5 mm in diameter Accuracy: Group A ( g/cc ) Group B ( g/cc ) to g/cc to g/cc to g/cc to g/cc to g/cc to g/cc Usage Several pieces of standard density floats with even density differences are placed in a density gradient solution filled glass cylinder. Place a few samples whose densities are unknown in the cylinder. Read the graduated scales where the samples rest. Correlation between reading of the scales on the cylinder in relation to the floats and the resting positions of the samples functions as a measure of the density gradient to determine the density of the samples. 1) Standard density floats can be manufactured to provide density values of even intervals (for Group A floats, in the range from to g/cc) 2) Each standard density float is supplied with a verification certificate with traceability data. 3) If resultant readings are entered into a personal computer (with Lotus or Excel software), the density values can be easily calculated. 4) A number of samples can be simultaneously measured. MEASURING PROCEDURES Place floats at even intervals in the density gradient tube. Place samples to measure in the tube. Read the locations of samples with the graduated scale on the tube. Enter data values to accessory data mathematical calculation software (which operates on Lotus or Excel) Density values are calculated according to the method of least squares. 3
4 No. n x y xy x n = x = y = xy = x 2 = y ax b a DENSITY DENSITY CALIBRATION CURVE SHIBAYAMA SCIENTIFIC CO., LTD. SOFTWARE for Density Gradient Liquid Preparation, Density Calculation and Graph Printout Density Calculation Calculate density values by entering the tube scale readings of the samples boxes in the table. The least squares method is used for calculation. To apply the 1. least squares method, fulfill the table with necessary values n Input the standard density floats tube scale readings and actual X density of the standard density floats. Y Y n Scale Reading X Density Y Theoretical Value Y x y xy X Scale Reading: x = Tube scale reading of standard density float Y Density Value: y = Actual density of standard density float n When graphing the resultant data, 'x' and 'y' become X-axis n (horizontal) and Y-axis (vertical). Y y ax b 'n' is the number of standard density floats. Generally, one float y is used for each density value, n = The Y theoretical value 'y' is obtained by the following table and expressed by the equation y = ax + b. 2. Using the data collected in 1., the following table can be obtained. No. n x y xy x n = x = y = xy = x 2 = a b y By using the values in the total row, the least squares method equation can be obtained. y Equation: y = ax + b a = b = After obtaining values for a and b, the theoretical value for y can be calculated. 42 Verify the calculation equation by substituting an arbitrary y number for the tube scale reading. 3. Tube Scale Reading: 42 Density Value (y theoretical value): Input the tube scale reading for the sample to obtain, a density value can be obtained. Tube scale reading for the sample Density calculated from tube scale reading SCALE 50 4
5 cm/min 100(W) 200(D) 335(H) mm, 3.5 kg AC100, 50/60 Hz, V 6 W ml/h AC100, 50/60 Hz, V 20 W SHIBAYAMA SCIENTIFIC CO., LTD. OPTIONAL UNITS Automatic Constant Speed Sample Lift This unit is used to minimize the disturbance of density gradient liquid column in the tube by automatically lifting a sample up or down at a constant speed. This unit can maintain the effective density gradient two to three times longer then when using the standard accessory float lifting rod. Prolonging the life of the density gradient saves time and measurement costs. This unit is mounted on the stirring motor base located at the top of the constant temperature oven. Main Specifications Lifting Up/Down Speeds: 0.9 to 7.5 cm/min. Control Method: Integrated timer Dimensions and Weight: 100 (W) 200(D) 335(H) mm, 3.5 kg Power Requirements: 100 VAC, 50/60 Hz. 6 W Automatic Density Gradient Liquid Maker Composed of a pump and a controller, this unit is used to make density gradient liquid with a good linearity. Gradient can be made liquid with significantly improved ease and stability compared with the standard accessory manual liquid maker kit which uses a siphon. This is recommended for less experienced users. This unit is installed on the top of the constant temperature oven. Main Specifications Control Method: Volume sensor Tubing Pump: 4-gang type Output Volume: 32 to 450 ml/h 4 Magnetic Stirrer: 100 to 1500 rpm Power Requirements: 100 VAC, 50/60 Hz. 20 W 510/540 kcal/h AC100, 50/60 Hz, V 370 W Standard Density Floats Other than those supplied as standard accessories Built-in Type Cooling Circulator This unit is installed under the constant temperature oven to keep it at those below room temperature. Main Specifications Control Power: 510/540 kcal/h Surrounding Temperature Requirements: 5 to 40 Cooling Water Temperature Range: 5 to 25 Power Requirements: 100 VAC,50/60 Hz. 370 W ORDERING INFORMATION 1. Measuring temperature 2. Measuring range 3. Range, quantity and accuracy for standard density floats to be supplied as standard accessory 4. Optional item requirements 5
6 A B Measuring Constant Temperature Oven A B 5 40 Temperature Range (Type A and B): W D H mm kg kg A BAC100V 12A17A Lmm mm 850 mm 500 mm g/cc SYSTEM COMPOSITION AND MAIN SPECIFICATIONS Type A Type B Room temperature +5 to 40 A B0.05 When optional built-in type cooling circulator is used, 15 to 40 A B Temperature Accuracy (Types A and B): PID Temperature Control (Types A and B): PID control 6 4 with auto tuning function Number of Cylinders: 6 4 Capacity: 134 liters 75 liters Size (W D H mm): Weight: 95 kg 75 kg Power Requirements (Types A and B): 100 VAC 12 A When optional units are used, 17 A Measuring Glass Tubes Size (L Inside Dia.): 1100 mm mm 32 Scale Range: 850 mm 500 mm (1 mm intervals) Standard Density Floats Standard Accessories (0.800 to g/cc): A B 30 pcs. 10 pc. 3.5" FD Lotus Excel Note: If floats of other densities and accuracy are needed, place an order as optional accessories, 1 2 Soft ware (Types A and B) Medium: 3.5" FD Operated on Lotus or Excel 1) Density gradient liquid preparation 2) Density calculation and graph printout Manual Density Gradient Liquid Maker 3 2 consisting of: R Adjusting bottle 2 pcs. (2 L) 2 pcs. (1 L) R Silicone plug 3 pcs. 2 pcs Teflon R tube Tygon R tube 1 1 Roller clamp 2 pcs. 2 pcs. Safety pipette 1 pc. 1 pc. A B Cylinder weight 1 pc. 1 pc. 1 Standard Accessories and Documents (Types A and B) 1 1) Thermometer (with calibration certificate)... 1 pc. 1 2) Float lifting rod pc. 1 3) Operation manual copy 1 4) Test data sheet (with calibration certificate).. 1 copy 1 5) Standard density float test certificate copy 6) Warranty (attached to item 4) copy A B 2 Recommended Maintenance Service Intervals 1. Re-verification of standard density floats.. 2-year 2 2. Thermometer year 3. Measuring constant temperature oven year Distributor: TEL: FAX: SHIBAYAMA SCIENTIFIC CO., LTD. 11-8, Minami-Ohtsuka 3-chome, Toshima-ku, TEL: Tokyo Japan FAX: [email protected]
CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST
CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST 1 Permeability is a measure of the ease in which water can flow through a soil volume. It is one of the most important geotechnical parameters. However,
Apr 17, 2000 LAB MANUAL 1302.0. 1302 PARTICLE SIZE ANALYSIS OF SOILS AASHTO Designation T 88 (Mn/DOT Modified)
Apr 17, 2000 LAB MANUAL 1302.0 1302 PARTICLE SIZE ANALYSIS OF SOILS AASHTO Designation T 88 (Mn/DOT Modified) 1302.1 SCOPE This method describes a procedure for the quantitative determination of the distribution
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines
PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines On customer request it is possible to supply: Benches for PCB Oven for PCB Chemicals
PART I SIEVE ANALYSIS OF MATERIAL RETAINED ON THE 425 M (NO. 40) SIEVE
Test Procedure for PARTICLE SIZE ANALYSIS OF SOILS TxDOT Designation: Tex-110-E Effective Date: August 1999 1. SCOPE 1.1 This method covers the quantitative determination of the distribution of particle
Test Bank - Chapter 3 Multiple Choice
Test Bank - Chapter 3 The questions in the test bank cover the concepts from the lessons in Chapter 3. Select questions from any of the categories that match the content you covered with students. The
Chapter 3 Student Reading
Chapter 3 Student Reading If you hold a solid piece of lead or iron in your hand, it feels heavy for its size. If you hold the same size piece of balsa wood or plastic, it feels light for its size. The
INSTRUCTIONS 56-1190-98. Edition AC
Sephacryl S-100 High Resolution Sephacryl S-200 High Resolution Sephacryl S-300 High Resolution Sephacryl S-400 High Resolution Sephacryl S-500 High Resolution INSTRUCTIONS Sephacryl High Resolution chromatography
DUGARD. Machine Tools Since 1939. Dugard 700L Series Heavy Duty CNC Lathes. www.dugard.com
DUGARD Machine Tools Since 1939 Dugard 700L Series Heavy Duty CNC Lathes www.dugard.com Dugard 700L Heavy Duty CNC Lathe 2000, 3000 or 4000mm bed length Designed for easy and convenient operation The concave
BB-18 Black Body High Vacuum System Technical Description
BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The
Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION
M A N U A L M E L - T E M P THE LOWEST COST MELTING POINT APPARATUS FOUND ANYWHERE! Low cost unit Temperature range to 500 C Aluminum casting conducts and radiates heat uniformly to capillaries and thermometer.
Incubator with mechanical convection
BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,
Multiple flasks. Easy to adapt. Stuart range of heating blocks
Heating Blocks The Stuart range of heating blocks have been developed in conjunction with DrySyn to provide the best possible solution for heating round bottom flasks. Combined with the Stuart range of
Solids, Volatile Dissolved and Fixed Dissolved
, 8277 Solids, Volatile Dissolved and Fixed Dissolved Gravimetric Method 1 Scope and Application: For wastewater. 1 Adapted from Standard Methods for the Examination of Water and Wastewater DOC316.53.001206
Specials. www.ika-apparatuur.nl. designed. 3rd edition 2015 English. for scientists 1
Specials www.ika-apparatuur.nl 3rd edition 2015 English designed for scientists 1 IKA Specials Quarterly Campaign III Three is a charm With over 100 years of experience, IKA continues to strive for delivering
This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular
Nitrogen, Ammonia. Known Addition ISE Method 1 Method 10002 Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table
Nitrogen, Ammonia DOC316.53.01234 Known Addition ISE Method 1 Method 10002 Minimum of 0.8 mg/l NH 3 N Scope and application: For wastewater 2. Ammonia ISE 1 Adapted from the Standard Methods for the Examination
To measure the solubility of a salt in water over a range of temperatures and to construct a graph representing the salt solubility.
THE SOLUBILITY OF A SALT IN WATER AT VARIOUS TEMPERATURES 2007, 1995, 1991 by David A. Katz. All rights reserved. Permission for academic use provided the original copyright is included. OBJECTIVE To measure
UNITOR VACUUM cleaners
UNITOR VACUUM cleaners Unitor VCD15 a compact, heavy-duty dry vacuum cleaner for accommodation areas The smallest unit in the Unitor range, the VCD15 is purpose-made for use on cruise and passenger vessels.
Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list
VITOSOL 100 Flat collectors for the utilisation of solar energy Data Sheet Part nos. and prices: see price list File in: Vitotec 1 Manual, Index 16 Vitosol 100 Type s 1.7 Vitosol 100 Type s 2.5 Vitosol
WATERBATHS AND OILBATHS
WATERBATHS AND OILBATHS New bath generation, still more accurate through innovative control technology Combined start delay and hold time; on Excellent models setpoint-dependent More security through at
Apr 17, 2000 LAB MANUAL 1811.0
Apr 17, 2000 LAB MANUAL 1811.0 1811 BULK SPECIFIC GRAVITY (GMB) AND DENSITY OF COMPACTED BITUMINOUS SPECIMENS USING PARAFFIN OR PARAFILM ASTM Designation D 1188 (MN/DOT Modified) 1811.1 SCOPE This test
FRACTION COLLECTOR. Microcomputer Controlled CHF122SC
FRACTION COLLECTOR Microcomputer Controlled CHF122SC From open column to HPLC liquid chromatography and general liquid samplings, the Super Fraction Collector, model CHF122SC has a wide range of uses.
Homogenizer with Direct Controller. Digital Homogenizer with Remote Controller. Homogenizing Stirrer, for use with Tissue Grinders.
- Useful for All Dispersing and Homogenizing Applications - High Speed / High Quality / Low Noise : Max. 27.000 RPM (without load) - Speed & Power Control Optimized for a Sample - High Efficiency Dispersing
IDEAL AND NON-IDEAL GASES
2/2016 ideal gas 1/8 IDEAL AND NON-IDEAL GASES PURPOSE: To measure how the pressure of a low-density gas varies with temperature, to determine the absolute zero of temperature by making a linear fit to
Manual: Nearshore CPT Testing NEARSHORE CONE PENETRATION TESTING (TOP PUSH TECHNIQUE)
Manual: Nearshore CPT Testing NEARSHORE CONE PENETRATION TESTING (TOP PUSH TECHNIQUE) Nearshore CPT is not as difficult as it might seem. Most CPT companies do already have most of the necessary equipment
Activity P13: Buoyant Force (Force Sensor)
July 21 Buoyant Force 1 Activity P13: Buoyant Force (Force Sensor) Concept DataStudio ScienceWorkshop (Mac) ScienceWorkshop (Win) Archimedes Principle P13 Buoyant Force.DS P18 Buoyant Force P18_BUOY.SWS
T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A
T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test
Math Matters: Dissecting Hydrometer Calculations
Math Matters: Dissecting Hydrometer Calculations By Jonathan Sirianni, Laboratory Assessor In the 16th century Galileo and the Tower of Pisa made famous the fact that two objects, no matter their mass,
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
Digital Hotplate. Stirrers. Compact & Round Plate Type Hotplate Stirrers. Analog Hotplate Stirrer. Digital Hotplate
- Smart Design of Body made by Aluminum Die-Casting - -Chemical/Acid Resistance - Superior Temperature Uniformity : Less than 10% on the at Ambient Temperature - User s Self -Compensation Function : to
Heating oven with mechanical convection
FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous
AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL
FUEL CONSUMPTION MEASUREMENT AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL Description The combination of AVL Fuel Mass Flow Meter and AVL Fuel Temperature Control is a high precise and continuous
KS-70. Catheterization Table GENERAL
PD505-009A Catheterization Table KS-70 GENERAL This Catheterization Table KS-70, which is combined with X-ray high voltage generator, X-ray tube assembly, X-ray image system (Image Intensifier, Flat Panel
Closed Loop Pressure Control for the Extrusion Process
Closed Loop Pressure Control for the Extrusion Process By John Pacini Updated by Douglas Joy Extrusion is a continuous process and successful economic production depends on maintaining stable output and
Laboratory Autoclave SN210/310/510,SQ510/810
1/5 Laboratory Autoclave SN210/310/510,SQ510/810 SN210/310/510,SQ510/810 The highest temperature of 135deg.C Upwards opening lid SN210 SN310 SN510 Effective Capacity : 20LEffective Capacity : 32L Effective
AP Physics 1 and 2 Lab Investigations
AP Physics 1 and 2 Lab Investigations Student Guide to Data Analysis New York, NY. College Board, Advanced Placement, Advanced Placement Program, AP, AP Central, and the acorn logo are registered trademarks
18 Conductometric Titration
Lab Activity 18 CONDUCTOMETRIC TITRATION LAB ACTIVITY 18 Conductometric Titration Background Titration is the a method of determining the concentration of an unknown solution (the analyte) by reacting
E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE
E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE References for Nuclear Magnetic Resonance 1. Slichter, Principles of Magnetic Resonance, Harper and Row, 1963. chapter
ADU 5. Automatic Distillation Unit
ADU 5 Automatic Distillation Unit Atmospheric Distillation Distillation tests are used to characterize the volatility of petrochemical products. These volatility characteristics are a critical measurement
Physical Properties of a Pure Substance, Water
Physical Properties of a Pure Substance, Water The chemical and physical properties of a substance characterize it as a unique substance, and the determination of these properties can often allow one to
The NEW Advanced Range of Portable Temperature Calibrators PROVISIONAL. Portable Dry Blocks, Liquid Baths and Multi-functional Heat Sources
PROVISIONAL The Source for Calibration Professionals Portable Dry Blocks, Liquid Baths and Multi-functional Heat Sources The NEW Advanced Range of Portable Temperature Calibrators Advanced Range Isotech
Safety at a high level!
SIKA Level Switch SIKA Level Switch Safety at a high level! Convincing Advantages easy and reliable method to monitor fluid levels proven float principle easy side installation using threads ¾" or ½" BSP
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
A H M 531 Penetration & Ring & Ball & Ductility & Flash & Fire point By: Mu'men Al-Otoom
The Civil Engineering Center 1 Visit www.ahm531.com for more lecture notes and E-book! The Civil Engineering Center 2 Visit www.ahm531.com for more lecture notes and E-book! Introduction : The grades of
HFM Heat Flow Meter Thermal Conductivity Analyzer
HFM Heat Flow Meter Thermal Conductivity Analyzer Introduction An insulating material is a material with low thermal conductivity, which in the construction industry, equipment manufacturing, or the production
BLOOD COLLECTION MIXER
USER S MANUAL BLOOD COLLECTION MIXER Model CM735 No. CAT.CM73522Ce Centron Technologies Corporation 319-25 Sadang-4-dong, Dongjak-ku Seoul, Korea 156-823 Tel. +82-2.522.7807 Fax +82-2.522.7806 Table of
Experiment 1: Colligative Properties
Experiment 1: Colligative Properties Determination of the Molar Mass of a Compound by Freezing Point Depression. Objective: The objective of this experiment is to determine the molar mass of an unknown
Physics 181- Summer 2011 - Experiment #8 1 Experiment #8, Measurement of Density and Archimedes' Principle
Physics 181- Summer 2011 - Experiment #8 1 Experiment #8, Measurement of Density and Archimedes' Principle 1 Purpose 1. To determine the density of a fluid, such as water, by measurement of its mass when
Soil Testing Soil index properties 24. Cone Penetrometer Method BS 1377, 1924-2, EN DD ENV 1997-2. Semi-Automatic Cone Penetrometer
24 Soil index properties Soil Index Properties Soil index properties are used extensively by engineers to discriminate between the different kinds of soil within a broad category, e.g. clay will exhibit
Related concepts Kohlrausch s law, equivalent conductivity, temperature dependence of conductivity, Ostwald s dilution law.
Conductivity of strong and weak electrolytes TEC Related concepts Kohlrausch s law, equivalent conductivity, temperature dependence of conductivity, Ostwald s dilution law. Principle It is possible to
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Microwave Meter. Instruction Manual
Microwave Meter 840046 Instruction Manual Microwave Meter 840046 Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN
Separation of Amino Acids by Paper Chromatography
Separation of Amino Acids by Paper Chromatography Chromatography is a common technique for separating chemical substances. The prefix chroma, which suggests color, comes from the fact that some of the
PERMEABILITY TEST. To determine the coefficient of permeability of a soil using constant head method.
PERMEABILITY TEST A. CONSTANT HEAD OBJECTIVE To determine the coefficient of permeability of a soil using constant head method. need and Scope The knowledge of this property is much useful in solving problems
EXPERIMENT 10 CONSTANT HEAD METHOD
EXPERIMENT 10 PERMEABILITY (HYDRAULIC CONDUCTIVITY) TEST CONSTANT HEAD METHOD 106 Purpose: The purpose of this test is to determine the permeability (hydraulic conductivity) of a sandy soil by the constant
AP1 Oscillations. 1. Which of the following statements about a spring-block oscillator in simple harmonic motion about its equilibrium point is false?
1. Which of the following statements about a spring-block oscillator in simple harmonic motion about its equilibrium point is false? (A) The displacement is directly related to the acceleration. (B) The
Table of Content. Enzymes and Their Functions Teacher Version 1
Enzymes and Their Functions Jeisa Pelet, Cornell University Carolyn Wilczynski, Binghamton High School Cornell Learning Initiative in Medicine and Bioengineering (CLIMB) Table of Content Title Page Abstract..
Determination of the enthalpy of combustion using a bomb calorimeter TEC
Determination of the enthalpy of TEC Related concepts First law of thermodynamics, Hess s law of constant heat summation, enthalpy of combustion, enthalpy of formation, heat capacity. Principle The bomb
Chemistry 212 VAPOR PRESSURE OF WATER LEARNING OBJECTIVES
Chemistry 212 VAPOR PRESSURE OF WATER LEARNING OBJECTIVES The learning objectives of this experiment are to explore the relationship between the temperature and vapor pressure of water. determine the molar
Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid
Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid Introduction Many metals react with acids to form hydrogen gas. In this experiment, you will use the reactions
Pre-Lab Notebook Content: Your notebook should include the title, date, purpose, procedure; data tables.
Determination of Molar Mass by Freezing Point Depression M. Burkart & M. Kim Experimental Notes: Students work in pairs. Safety: Goggles and closed shoes must be worn. Dispose of all chemical in the plastic
Determination of Viscosity Using A Brookfield Viscometer for Conditioning Polymers
LUBRIZOL TEST PROCEDURE TP-N01004 Edition: December 2, 2013 Previous Editions: August 10, 2000 / November 1, 2011 Determination of Viscosity Using A Brookfield Scope A material's flow property is an important
Pin & Vee Block Test Machine
Pin & Vee Block Test Machine Picture of the apparatus Used in Standard Test Methods ASTM Standards D 2670, D2626, D3233, D5620 Federal Test Methods FTM-791-3807.1, FTM-791-3812.1 Chrysler Corporation 461-C-84-01,
Triple Point Experiment
Equipment List Rotary vane vacuum pump 2-stage, 2 to 7 CFM. For example, Edwards 2M2 (2 CFM), Edwards RV5 (3.5 CFM), Edwards E2M8 (6.7 CFM) or equivalent. Bell jar Nalgene polycarbonate plastic, 5-5/8
Heating oven with mechanical control
ED series 53 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C (572 F). Thanks
Magnetic Stirrers. Patented. Ncm % RET control-visc with white coated heating plate! Mixing Magnetic stirrers
Magnetic Stirrers Patented RET control-visc with white coated heating plate! > Offers excellent chemical resistance > Easy to clean RET controlvisc kg Integrated temperature sensor for precise temperature
6 H2O + 6 CO 2 (g) + energy
AEROBIC RESPIRATION LAB DO 2.CALC From Biology with Calculators, Vernier Software & Technology, 2000. INTRODUCTION Aerobic cellular respiration is the process of converting the chemical energy of organic
Laboratory Exercise: Calibration of a Thermometer
CHEM 109 Introduction themistry Revision 3.1 Laboratory Exercise: Calibration of a Thermometer In this exercise we will calibrate a stem-type thermometer and then use it to correctly measure the Air temperature
ph: Measurement and Uses
ph: Measurement and Uses One of the most important properties of aqueous solutions is the concentration of hydrogen ion. The concentration of H + (or H 3 O + ) affects the solubility of inorganic and organic
Experiment 13: Determination of Molecular Weight by Freezing Point Depression
1 Experiment 13: Determination of Molecular Weight by Freezing Point Depression Objective: In this experiment, you will determine the molecular weight of a compound by measuring the freezing point of a
Buoyant Force and Archimedes Principle
Buoyant Force and Archimedes Principle Predict the behavior of fluids as a result of properties including viscosity and density Demonstrate why objects sink or float Apply Archimedes Principle by measuring
Experiment 4 (Future - Lab needs an unknown)
Experiment 4 (Future - Lab needs an unknown) USING A ph TITRATION TO DETERMINE THE ACID CONTENT OF SOFT DRINKS 2 lab periods Reading: Chapter 9, 185-197; Chapter 10, pg 212-218; Chapter 14 pg 317-323,
1. Introduction. 2. Components. 3. Optical Specifications. 4. Electric Specifications. 5. Dimension. 6. Operating Environment. 7.
SPECIFICATIONS Super Model: XHS-220S1 Class Solar Simulator 1. Introduction 2. Components 3. Optical Specifications 4. Electric Specifications 5. Dimension 6. Operating Environment 7. Warranty SAN-EI ELECTRIC
Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump
Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity
Direct ISE Method Method 8359 10 to 1000 mg/l Na + Sodium ISE
Sodium DOC316.53.01240 Direct ISE Method Method 8359 10 to 1000 mg/l Na + Sodium ISE Scope and application: For drinking water and process water. Test preparation Instrument-specific information This procedure
Activity P13: Buoyant Force (Force Sensor)
Activity P13: Buoyant Force (Force Sensor) Equipment Needed Qty Equipment Needed Qty Economy Force Sensor (CI-6746) 1 Mass and Hanger Set (ME-9348) 1 Base and Support Rod (ME-9355) 1 Ruler, metric 1 Beaker,
XI / PHYSICS FLUIDS IN MOTION 11/PA
Viscosity It is the property of a liquid due to which it flows in the form of layers and each layer opposes the motion of its adjacent layer. Cause of viscosity Consider two neighboring liquid layers A
CHAPTER 29 VOLUMES AND SURFACE AREAS OF COMMON SOLIDS
CHAPTER 9 VOLUMES AND SURFACE AREAS OF COMMON EXERCISE 14 Page 9 SOLIDS 1. Change a volume of 1 00 000 cm to cubic metres. 1m = 10 cm or 1cm = 10 6m 6 Hence, 1 00 000 cm = 1 00 000 10 6m = 1. m. Change
User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510
User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Unit 7 Contact: Mr S C Sparks Solent Industrial Estate Tel: +44 (0)1489 790296 Hedge End Fax: +44 (0)1489 790294 Southampton E-Mail: [email protected]
EasyTrack 2 Accessories List
EasyTrack 2 Accessories List DATA LOGGER ET6061 EasyTrack2 Data Logger (6 Channel) Measurement Range -150 to 500 C (-238 F to 932 F) Accuracy ±0.5 C (0.9 F). Type K thermocouple. 6000 readings per channel.
Experiment 12E LIQUID-VAPOR EQUILIBRIUM OF WATER 1
Experiment 12E LIQUID-VAPOR EQUILIBRIUM OF WATER 1 FV 6/26/13 MATERIALS: PURPOSE: 1000 ml tall-form beaker, 10 ml graduated cylinder, -10 to 110 o C thermometer, thermometer clamp, plastic pipet, long
Ubbel. Viscometers and their range of use. Viscometer type. Cannon-Fenske reverse flow BS/IP-U tube reverse flow. Cannon-Fenske-Routine
Viscometers and their range of use Measurement substance property Viscometer type Ubbelohde Micro Ubbelohde TC Ubbelohde Ostwald Micro Ostwald Cannon-Fenske-Routine Cannon-Fenske reverse flow BS/IP-U tube
Experiment 6 ~ Joule Heating of a Resistor
Experiment 6 ~ Joule Heating of a Resistor Introduction: The power P absorbed in an electrical resistor of resistance R, current I, and voltage V is given by P = I 2 R = V 2 /R = VI. Despite the fact that
List of instruments required for Innovation Projects sanctioned in Deshbandhu College for the year 2015-16
Fresh quotations in sealed envelope are invited addressed to The Principle, Deshbandhu College, for the purchase of equipment required for Innovation Project 2015-16 Closing date is 15 November, 2015 List
Standard Test Procedures Manual
STP 206-4 Standard Test Procedures Manual Section: 1. SCOPE 1.1. Description of Test This method describes the procedure for determining the liquid limit, plastic limit and the plasticity index of coarse-grained
One- and Two-dimensional Motion
PHYS-101 LAB-02 One- and Two-dimensional Motion 1. Objective The objectives of this experiment are: to measure the acceleration of gravity using one-dimensional motion to demonstrate the independence of
Determination of the enthalpy of combustion using a bomb calorimeter TEC. Safety precautions
Safety precautions Naphthalene is harmful if swallowed. May cause cancer. Is further very toxic to aquatic organisms and can have long-term harmful effects in bodies of water. Equipment 1 Bomb calorimeter
TechCut 4 Precision Low Speed Saw
Product Brochure TechCut 4 Precision Low Speed Saw 3" - 6" Blade Range Digital Speed Display 1-Micron Sample Indexing Spring-Loaded Dressing Stick Attachment All Aluminum & Stainless Steel Construction
Card Fibre Transfer Test ver 1.0. Pc-Program Application BY ITRU GROUP LTD
Card Fibre Transfer Test ver 1.0 Pc-Program Application BY ITRU GROUP LTD Table of Contents 1-1 Test Results... 2 1-2 Introduction to Carding Machine... 4 1-3 Technical terms and definitions and their
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
INDEX 03010-1 DESCRIPTION 2 03010-2 MATERIALS 2 03010-3 APPROVAL OF SUBBASE COURSE 3 03010-4 CONSTRUCTION 4 03010-5 MEASUREMENT 6 03010-6 PAYMENT 6
03010_Dec22_2009.pdf Page 1 of 5 INDEX Page 03010-1 DESCRIPTION 2 03010-2 MATERIALS 2 03010-3 APPROVAL OF SUBBASE COURSE 3 03010-4 CONSTRUCTION 4 03010-5 MEASUREMENT 6 03010-6 PAYMENT 6 03010_Dec22_2009.pdf
Experiment 446.1 SURFACE TENSION OF LIQUIDS. Experiment 1, page 1 Version of June 17, 2016
Experiment 1, page 1 Version of June 17, 2016 Experiment 446.1 SURFACE TENSION OF LIQUIDS Theory To create a surface requires work that changes the Gibbs energy, G, of a thermodynamic system. dg = SdT
Micro GC Fusion Pre-Installation Checklist
Site Preparation Proper site preparation prior to installing is very important. Contact INFICON (www.inficon.com) with any questions regarding site preparation. NOTE: Checkboxes ( ) identify hardware that
LAB #3: MEASURING SPECIFIC GRAVITY AND DENSITY. Set-up and Materials for Experiment
Set-up and Materials for Experiment 1 OVERVIEW The mass density of a substance is a measure of the mass that that substance contains in a given volume. Mathematically is written: ρ = m V ( Density = Volume
Enzyme Pre-Lab. Using the Enzyme worksheet and Enzyme lab handout answer the Pre-Lab questions the pre-lab must be complete before beginning the lab.
Enzyme Pre-Lab Using the Enzyme worksheet and Enzyme lab handout answer the Pre-Lab questions the pre-lab must be complete before beginning the lab. Background: In this investigation, you will study several