Technical Manual MDT VisuControl Easy
|
|
|
- Holly Bradley
- 9 years ago
- Views:
Transcription
1 6/2014 Technical Manual MDT VisuControl Easy VC-EASY.01
2 1 Content 1 Content Overview Overview and Usage Exemplary circuit diagram Structure & Handling Settings at the ETS Software Starting up Using VisuControl Easy as Communication interface Connection settings for the APP Internal access External access App Representation & available Menus App Representation Available Menus Approach to project planning Reference ETS Parameter Menu General Password settings Connection settings Menu Formatting of the areas Menu Formatting of the function types Menu Function selection Area allocation Function allocation Visibility Sorting Menu Status logic Area allocation Logical connections and function name Visibility Sorting Menu Weather data
3 6 Overview functions Function type: Switching Function selection: Switching & Switching (separated) Function type: Light Function selection: Light On/Off & Light On/Off (divided) Function selection: Dimmer Function type: Dimming (RGB) Function type: Shutter/Blinds Function selection: Shutter/Blinds Function selection: Shutter/Blinds with height position Function selection: Shutter/Blinds with height position and slats Function type: Room temperature controller Function selection: Room temperature controller Function selection: Room temperature controller with HVAC mode Function selection: Room temperature controller with HVAC modeand Status Function type: Scenes Function type: Multimedia Funktion selection: Multimedia control Function selection: Multimedia control with volume Function selection: Volume Function type: Status Function type: Other Index List of figures List of tables Attachment Statutory requirements Routine disposal Assemblage Sample projects Example 1 (easy) Example 2 (advanced) Datasheet
4 2 Overview 2.1 Overview and Usage VisuControl Easy is an object server, which can establish a connection between a KNX bus and each point on the LAN. Together with the VisuControl Easy APP, which is available for ios devices in the itunes Store, an access to your own KNX system of mobile IOS devices is possible. The VisuControl Easy and thus also the presentation of the APP can be parameterized with 10 different areas and 15 different functions. A total of 250 communication objects can be displayed, which can be integrated in the KNX system. Furthermore Webcam URL s, Weather data and extensive logic functions for status indication can be integrated via the database. The app can be downloaded for free via the itunes Store (search word: VisuControl for KNX). In the APP a demo version is preinstalled, which can be started and tested without acquisition of the object server. The figure below gives a brief overview of the functions of the VisuControl Easy: Figure 1: Overview It is also possible to use the VisuControl Easy as a IP interface. 4
5 2.2 Exemplary circuit diagram Figure 2: Exemplary circuit diagram 5
6 2.3 Structure & Handling The VisuControl Easy is a top hat mounted rail device and has the following operating and display elements: Figure 3: Hardware module 1 = 12/24V Connector (only necessary if no PoE available) 2 = Bus connector 3 = KNX Status LED: lights green when bus voltage present flashes green when receiving / sending KNX telegrams 4 = Ethernet Status LED lights yellow when Ethernet connection present flashes yellow at telegram traffic 5 = RJ 45 socket for connection to the LAN 6 = Programming button 7 = Programming LED (red) 6
7 2.4 Settings at the ETS Software Selection at the product database: Manufacturer: MDT Technologies Product family: Product type: Medium Type: Twisted Pair (TP) Product name: Visu Control Easy Order number: VC Easy Starting up After wiring the device, the assignment of the physical address and the download of the selected functionality can be done. The illustration in the APP is achieved by the transfer of the database to the object server VisuControl Easy. It needs no further settings in the app itself. After loading a new parameterization in the object server, the App must be simply reloaded via the settings. Procedure: (1) Connect the interface with the bus, e.g. MDT USB interface (2) Set bus power up (3) Connect Ethernet (4) Set auxiliary voltage up if no Power over Ethernet is available (5) Press the programming button at the device(red programming LED lights) (6) Loading of the physical address out of the ETS Software by using the interface(red LED goes out, as well this process was completed successful) (7) Loading of the application, with requested parameterization (8) Load App with desired server (Free to download from itunes Store, keyword: "VisuControl Easy") At every restart and download of the VisuControl Easy, the device performs a read access of all linked group addresses. In this case, all group addresses at a distance of 1s are being requested. 7
8 2.6 Using VisuControl Easy as Communication interface At valid IP configuration (see Connection settings) of the Easy VisuControl, the device can be used as an interface to the KNX. The following settings are necessary: In the main view of ETS 4, the Settingsmust be choosen and here the button communication. All available connections are listed below configured connections. After clicking on the desired connection, it can be selected via the corresponding button. The Local settings button allows the adjustment of additional physical address that is used for the bus: Figure 4: Local settings To reserve this address, a dummy device can be inserted in the ETS project. The VisuControl Easy supports up to 5 simultaneous connections. For each compound, an additional physical address must be reserved. The first additional physical address is assigned via the ETS as described above. The remaining additional addresses can be assigned directly from the device itself. For this purpose, the learn button is at least a second to press during normal operation of the device. Then, the address assignment is as follows: Connection 2 is replaced by the next higher address than Connection 1, Connection 3 the next higher address than Connection 2, etc. Example: Connection 1 has the additional physical address Connection 2 is then obtained , Connection 3: , Connection 4: , Connection 5: The allocation of additional physical addresses is indicated by rapid flashing of the learning LED. Prior to the assignment of the additional physical addresses is to examine whether these adresses are free. On delivery, only the additional physical address of the first connection is active, this is preset with To be able to use more than one connection at the same time, first the addressassignment must be performed. 8
9 2.7 Connection settings for the APP To configure the APP access, the VisuControl Easy makes a distinction between external and internal access. An interinal access means an access from a device that is like the VisuControl Easy on the same Wi Fi network. An external access means an access from a device which is not located in the same Wi Fi network, eg via the mobile Internet phone service provider. Below the procedure for the internal and external acess is described Internal access To prepare the VisuControl Easy for internal access, the device must only have a valid IP configuration (see Connection settings). The easiest way to achieve this is using the setting "DHCP". After downloading the application, the the APP starts with the following screen: Figure 5: Internal access The VisuControl Easy, which is currently located in the local network, is displayed directly to the selected device name under local server (here MDT VC Easy). This can be selected now. 9
10 2.7.2 External access The external access is usually implemented by using a DNS service. The DNS service allows to make the VisuControl Easy accessible via a host name. The following data is required: Port adjusted IP of the VisuControl Easy The following figure gives an overview of the operation: Figure 6: External access Adjust DNS Address: To set up the external access, at first a host name must be applied with a DNS service, e.g. on the page Here you can register for free and then, a new IPv4 host can be added. For our example, the hostname knxhome.spdns.de with the IP was created. 10
11 Router Settings: At first the port must be forwareded in the router. At Fritzbox routers this setting is found under Internet > Shares > port clearances. There you can forward the port with the registered IP of the VisuControl Easy. The IP of the VisuControl Easy can be found either under the connection settings, if you have set a static IP address, or in the ETS under Settings > Communication. Here all available connections are listed, including the VisuControl Easy. In this example, the VisuControl Easy has the IP Now the DNS settings must be made in the router. This is done in a Fritzbox under the DynDNS settings, which you can find in the Advanced Settings menu > Dynamic DNS > Internet > releases. Instructions for various routers can be found on the wiki pages of spdns.de > Settings in the App: When starting the app, the host name must be entered below "Connect Manually", here knxhome.spdns.de. Also, the forwareded port is entered here (standard in VisuControl Easy): Figure 7: App Settings external connection# Now the mobile device can be connected tot he KNX system via the App. 11
12 3 App Representation & available Menus 3.1 App Representation The App can be sorted as well after functions as after areas. The functions and areas are already defined in the database for the most common functions. But it is also possible to change them arbitrary. The following pictures show the different sorts: Figure 8: App View: Sort after functions 12
13 Figure 9: App View: Sort after areas 13
14 3.2 Available Menus The following menus are available for adjusting the VisuControl Easy: General Here the password settings for the access protection of the app can be set. Furthermore, the connection settings and the settings for the server name and logo, which will appear later in the app, can be made here. Formatting of the areas Here 10 areas can be defined and any name can be given, which will appear later in the app. Later, the functions can be assigned to the areas. Formatting of the function types Here 15 function types can be defined. These function types can be assigned a text and an icon, which are displayed in the app. Later, the functions can be assigned to the types of functions. Function Selection In the function selection, the actual link between VisuControl Easy and KNX system is established. Up to 49 functions can be activated for each sub menus, for which then function are displayed. The individual functions can be assigned to the areas and types of functions in these sub menus. Furthermore, here the type of the function is defined. The functions can also be split and settings for visibility and advanced sorting can be made here. Depending on the settings, the communication objects are displayed for this function, which can be linked to the group addresses. So the connection between App and KNX is established. Status logic selection With the status logic objects, communication objects of the same data point type can be linked and collecting objects are created, such as Light floor or window EC. Weather data In the Weather Data menu, the data from weather stations or temperature sensors can be linked and displayed in the app. 14
15 4 Approach to project planning Figure 10: Approach to project planning 15
16 5 Reference ETS Parameter 5.1 Menu General The following picture shows the menu general: Figure 11: Menu General The settings for password, Logo, Device name, Webcam URL and Connection can be done in the menu general. Logo Selection The MDT Logo, KNX Logo or the VisuControl Easy Logo can be chosen. The logo appears in the app on the menu and when you start the app. Device Name The device name is also the server name. Up to max. 29 characters are adjustable. If the app runs on multiple VisuControl Easy access server, we recommend a more meaningful name. Webcam URL With the parameter Webcam URL a webcam can be integrated. This is then stored in the app as a URL on the home page and be called by a simple click. 16
17 5.1.1 Password settings The password defines the access to the App. The following settings are available: without password Es wird kein Passwort für den App Zugriff benötigt. with password Accessing the app requires a password. Distinction can be made between the user and administrator password. The password will be transmitted unencrypted. with encrypted password Accessing the app requires a password. Distinction can be made between the user and administrator password. To encrypt the password, the corresponding link from the ETS must be copied out and copied into the browser. Here the desired password can be entered in the following screen: Now the encrypted text: can be copied into the password box of the ETS. Now the password will be transmitted encrypted. When you start the app the password is entered in clear text, so in this case: Test 123 The app can be configured for both the general access as well as for the user to access. Different passwords for administrator and users will be given. For each function can be selected whether this feature is only available to the administrator or user and administrator. Thus, for example, simple switching functions and critical functions, such as heating control, are separated. If the same password is selected for the administrator and for the user, so user and administrator are the same. 17
18 5.1.2 Connection settings In the setting "IP Address Assignment" you can choose between DHCP and manual configuration. If the DHCP option is selected, the VisuControl Easy is automatically assigned a free IP address on the network. For manual configuration, the following sub menu where the IP address can be assigned manually static appears: Figure 12: manual IP Configuration In home networks, the IP assignment via DHCP is common. 18
19 5.2 Menu Formatting of the areas The following picture shows the menu formatting of the areas: Figure 13: Menu formatting of the areas The areas represent rooms or separated areas in the house. The functions can be assigned to the adjusted areas. A name must be selected from the drop down list for each area. This name is used in the other parameter settings. For the display in the app any name up to 30 characters can be specified. The app can sort on the selected areas in the settings (accessed by clicking the wrench icon) by setting Sort by select> area. 19
20 5.3 Menu Formatting of the function types The following picture shows the menu formatting of the function types: Figure 14: Menu formatting of the function types The function types are similar to the trades in the ETS view. By the function types functions with similar functionality can be grouped together. For each functional type any text can be specified, which then appear in the app. However, the standard text is used for the assignment of the individual functions to the types of functions, e.g. FKT1: Switching. In addition, a symbol can be selected for each type of function, which appears later in the app. The icon is displayed in the ETS as a preview The app can sort on the selected areas in the settings (accessed by clicking the wrench icon) by setting Sort by select> function. 20
21 5.4 Menu Function selection The functions that are to be used must be activated in the function selection menu. For activated functions, a submenu, function 1.49, in which the function can be parameterized appears on the left: Figure 15: Menu Function selection The submenu for the functions hast the following structure: Figure 16: Submenu function
22 5.4.1 Area allocation Each function can be assigned to a specific area. In order this function is stored in the adjusted area in the app. The following parameters are relevant to the area of assignment: Figure 17: Area allocation > Select the area in which the function is assigned to 2 > For a better orientation the name of the area is automatically supplemented for a better orientation, see5.2 Menu Formatting of the areas Function allocation Each function can be assigned to a particular type of function. In order this function is stored in the adjusted function type in the app. The following parameters are relevant for the functional assignment: Figure 18: Function allocation > Select the type of function in which the function is assigned to 2 > Allocation of the function; displayed selection is dependent on the function type, which is used, each function type has a number of predefined functions. 3 > The description is the text which you will see in the App. For a complete overview of all functions and their data point types and symbols have a look in chapter 6. 22
23 5.4.3 Visibility For each function can be determined whether this is set to the home page. Furthermore, functions can either be made visible only for administrators or for users and administrators. The following settings are available for this purpose: Figure 19: Visibility of functions > Setting to display function on the homepage 2 > Setting whether function should be visible only for administrator or for administrator and user Sorting Functions are normally automatically sorted according to the selected function type. In some situations, however, this is not useful, for example, when switched with a switching function between the operating modes of a room thermostat. For this case it is possible to cancel the default sorting and assign the function itself to a another function type. For this purpose, the following parameters are available: Figure 20: Sorting of the functions 23
24 5.5 Menu Status logic It can be displayed and configured up to 10 different extended objects for the status. The following figure shows the status logic menu selection, in which each object can be activated: Figure 21: Selection of the status logic For an activated status logic submenus status logic appears. The following figure shows the submenu for status logic 1..10: Figure 22: Status logic
25 5.5.1 Area allocation Each status logic can be assigned to a specific area. In order this function is stored in the adjusted area in the app. The following parameters are relevant to the area of assignment: Figure 23: Area allocation > Select the area in which the function is assigned to 2 > For a better orientation the name of the area is automatically supplemented for a better orientation, see 5.2 Menu Formatting of the areas Logical connections and function name Every status logic can be connected to 10 internal objects and an individual name can be assigned: Figure 24: Logical connection & Function name 25
26 1 > The description is the text, which is displayed in the App 2 > The adjusted objects are connected with the adjusted logical operator. The settings AND, OR, NAND, NOR are availbale. 3 > Here, the inputs of the logic function are determined. The object numbers of VisuControl Easy must be entered. If, for example, the object 10 and the object 11 should be inputs for the status logic, the value 10 must be entered for object number 1A and for object number 1B the value 11 must be entered. For the remaining object number 1C 1J.. a 0 (= disabled) is entered. So, we obtain a logic function with 2 inputs. Only objects of the length 1 Bit can be compared at the status logic! Visibility For every status logic can be specified whether this is set to the home page. Furthermore, status logics are can be made visible either only for administrators or for users and administrators. The following settings are available: Figure 25: Visibility of the status logic > Setting whether to display status logic to the home page 2 > Setting whether status logic should be visible only for administrator or for administrator and user Sorting Status logics are normally automatically sorted in the function type FKT 8: Status. In some situations, however, this is not useful and you want to assign a different function type in status logic. For this case it is possible to cancel the default sorting and assign the function itself another function type. For this purpose, the following parameters are available: Figure 26: Sorting of the function 26
27 5.6 Menu Weather data The following picture shows the menu for the weather data: Figure 27: Menu weather data 1 > About the area allocation, the weather data can be assigned to a specific area / room. If not they will be displayed only on the home. 2 > The description of the function is the name which is displayed in the app for the weather data. 27
28 3 > Up to 3 objects of DPT 9.0xx can be enabled. These objects have a length of 2 bytes and can be combined with the following data point types: DPT Temperature Unit: C DPT Luminous intensity Unit: Lux DPT Wind speed Unit: m/s DPT Air pressure Unit: Pa DPT Percental, e.g.: Humidity Unit: % DPT Air quality Unit: ppm (parts per million) DPT Volume Flow Unit: l/h DPT Rain amount Unit: l/h DPT Temperature Unit: F DPT Wind speed Unit: km/h The unit which is displayed in the App can be selected for each object. 4 > Additionally, up to two objects of size 1 bit can be activated, e.g. for weather alerts In the app the weather display is displayed, for example as follows: Figure 28: Weather data 28
29 6 Overview functions 6.1 Function type: Switching The following picture shows the available settings for the parameter function selection: Figure 29: Function type Switching The function type switching can be parameterized as normal switching or as switching separated. Switching: For this function, only one communication object can be parameterized. This function can have a name with up to 30 signs and can be assigned to an arbitrary area. Switching (separated): For this function, up to 5 communication objects can be parameterized. Each object/function can have a name with up to 15 signs. The assignment to the area is valid for all 5 objects. So, the separation of the functions allows using more than one object, but the flexibility is limited Function selection: Switching & Switching (separated) Name Length DPT Description Representation in the App DPT 00 Switch 1 Bit DPT Normal switching function On/Off for activating/deactivating DPT 01 Locking/Unlocking 1 Bit DPT Function for locking/unlocking DPT 02 Blinds Up/Down DPT 03 Open/Closed (garage) DPT 04 Open/Closed (window) DPT 05 Open/Closed DPT 06 On/Off (socket) 1 Bit DPT Driving function for shutter and blinds 1 Bit DPT Driving function for garage doors 1 Bit DPT Driving functions for electrical windows 1 Bit DPT General driving function 1 Bit DPT Switching function for sockets Table 1: Function selection switching 29
30 6.2 Function type: Light The function type can be parameterized as light On/off, light On/Off(divided) or as dimmer. Light On/Off: Only one communication object can be parameterized for this function. This function can have a name with up to 30 signs and can be assigned to an arbitrary area. Light On/Off (divided): For this function, up to 5 communication objects can be parameterized. Each object/function can have a name with up to 15 signs. The assignment to the area is valid for all 5 objects. So, the separation of the functions allows using more than one object, but the flexibility is limited. Dimmer: For tis function, standardly 3 objects are shown. These objects are one coherent function. So, only one name can be given and only one area and function type assignment can be done for this function. The presentation format can be choosen Function selection: Light On/Off & Light On/Off (divided) Name Length DPT Description Representation in the App Two buttons 1 Bit DPT Normal switching function with two buttons One button toggle 1 Bit DPT Toggle with one button One button send value 1 Bit DPT Table 2: Function selection light Switching function, which sends only one value, e.g. centrall On/Off and sends no state 30
31 6.2.2 Function selection: Dimmer At the dimmer function, you can choose between two presentation formats. The functions are identical. Presentation Description Representation in the App format Symbol Presentation as 0 100% bar, which represents the also the state Slider Presentation as Slider, which can also send absolute dimming commands by picking a certain value Table 3: Function selection Dimmer The following table shows the relevant communication objects: Type Name Length Usage Licht Switch On/Off 1 Bit Switching function for the dim channel, must be connected with the switching and state objects of the dimmer Licht Dimming relatively 4 Bit Step function of the dim channel Licht Dimming absolutely 1 Byte Sends absolute values to the dimmer, must be connected with the absolute and the state object of the dim channel Table 4: Communication objects dimmer 31
32 6.3 Function type: Dimming (RGB) The dimming function(rgb) can control RGB devices. It can be divided between two presentation formats: RGB objects: When controlling via RGB, a color wheel for direct dialing of each color is displayed. It can be controlled over 3 individual objects 0 to 100% or a 3 byte object. In addition the switching function must be connected. The view in the app is independent of the choice of control = Switching the RGB function 2 = Selection of the color = Actual adjusted color 4 = Selection of the brightness via slider 3 4 The following table shows the relevant communication objects for the controlling via 3 individual objects for green, blue and red: Type Name Length Usage RGB Total On/Off 1 Bit Switching function for RGB actuator must be connected with switching function and status RGB Red absolute 1 Byte Transmit the absolute value for this channel has to be connected to an absolute value and status RGB Green absolute 1 Byte Transmit the absolute value for this channel has to be connected to an absolute value and status RGB Blue absolute 1 Byte Transmit the absolute value for this channel has to be connected to an absolute value and status Table 5: Communication object individual objects RGB 32
33 The following table shows the relevant communication objects for the controlling via one 3 Byteobject: Typ Name Größe Verwendung RGB Total On/Off 1 Bit Switching function for RGB actuator must be connected with switching function and status RGB RGB combined object 3 Byte Transmit the absolute value for all channels, must be connected to 3 byte value, and 3 byte Status Table 6: Communication object RGB combined object HSV objects: When controlling via HSV, 3 single slider are displayed which can adjust the color, saturation and brightness manually. It can be controlled over 3 individual objects or a 3 byte object. In addition the switching function must be connected. The view in the app is independent of the choice of control = Switching the RGB function 2 = Actual adjusted color 3 3 = Selection of hue, saturation and brightness via slider The following table shows the relevant communication objects for the controlling via 3 individual objects for hue, saturation and brightness: Typ Name Größe Verwendung RGB Total On/Off 1 Bit Switching function for RGB actuator must be connected with switching function and status RGB H(Hue) absolute 1 Byte Transmit the absolute value for this channel has to be connected to an absolute value and status RGB S(Sat) absolute 1 Byte Transmit the absolute value for this channel has to be connected to an absolute value and status RGB V(Val) absolute 1 Byte Transmit the absolute value for this channel has to be connected to an absolute value and status Table 7: Communication objects HSV individual objects The following table shows the relevant communication objects for the controlling via one 3 Byteobject: Typ Name Größe Verwendung RGB Total On/Off 1 Bit Switching function for RGB actuator must be connected with switching function and status RGB HSV combined object 3 Byte Transmit the absolute value for all channels, must be connected to 3 byte value, and 3 byte Status Table 8: Communication objects HSV combined objects 33
34 6.4 Function type: Shutter/Blinds By using the Shutter/Blinds function, shutter and blinds can be driven. This can either be run as a simple drive function or additionally with absolute position commands Function selection: Shutter/Blinds The function Shutter/Blinds is an easy driving function without any informations about the state of the absolute position. Presentation format Description Representation in the App no further selection available Table 9: Function selection Shutter/Blinds A short press activates the Stop/Step function, a long press activates the driving function The following table shows the relevant communication objects: Type Name DPT Usage Blinds/ Shutter Blinds Up/Down 1 Bit Must be connected to the drive object of the blind /shutter function Blinds/ Shutter Blinds Stop/Step 1 Bit Must be connected to the stop/step object of the blind /shutter function Table 10: Communication object Shutter/Blinds function Function selection: Shutter/Blinds with height position The function Shutter/Blinds is an easy driving function which sends additional informations about the state of the absolute position. Presentation Description Representation in the App format Symbol A short press acticates the Stop/Step function, a long press activates the driving funcion Slider A short press acticates the Stop/Step function, a long press activates the driving function. Additional, the absolute position can be selected via the slider. Table 11: Function selection Shutter/Blinds with height position 34
35 The following table shows the relevant communication objects: Type Name DPT Usage Blinds/ Shutter Blinds Up/Down 1 Bit Must be connected to the drive object of the blind /shutter function Blinds/ Shutter Blinds Stop/Step 1 Bit Must be connected to the stop/step object of the blind /shutter function Blinds/ Shutter Blind position 1 Byte Must be connected with the objects for the selection of the absolute position and the status of the absolute position of the channel which sould be controlled Table 12: Communication objects shutter/blinds with height position Function selection: Shutter/Blinds with height position and slats The function Shutter/Blinds is an easy driving function which sends additional informations about the state of the absolute position of the blinds and slats. Presentation Description Representation in the App format Symbol A short press acticates the Stop/Step function, a long press activates the driving funcion. Above: Driving function Below: Slat function Slider A short press acticates the Stop/Step function, a long press activates the driving function. Additional, the absolute position can be selected via the slider. Above: Driving function Below: Slat function Table 13: Function selection shutter/blinds with height position and slats 35
36 Die nachfolgende Tabelle zeigt die dazugehörigen Kommunikationsobjekte: Type Name DPT Usage Blinds/ Shutter Blinds Up/Down 1 Bit Must be connected to the drive object of the blind /shutter function Blinds/ Shutter Blinds Stop/Step 1 Bit Must be connected to the stop/step object of the blind /shutter function Blinds/ Shutter Blind position 1 Byte Must be connected with the objects for the selection of the absolute position and the status of the absolute position of the channel which sould be controlled Blinds/ Shutter Slat position 1 Byte Must be connected with the objects for the selection of the absolute position of the slats and the status of the absolute position of the slats of the channel which sould be controlled Table 14: Communication objects shutter/blinds with absolute height and slats 36
37 6.5 Function type: Room temperature controller The room temperature controller function enables the adjustment of the current setpoint temperature and displays the current room temperature. At the function selections with HVAC mode, also a mode switching is possible Function selection: Room temperature controller The setpoint can be shifted via 1 bit objects as well as a a new basic comfort value can be entered via a 2 Byte object. The presentation and function is the same in the app in both cases. Adjust the Description Representation in the App setpoint on Setpoint shift with 1 Bit object The setpoint is shifted via a normal 1 Bit object, which changes the setpoint according tot he setting sin the room temperature controller. 1 = current temperature 1 Base setpoint The setpoint is set as new base setpoint. The change per press is adjusted to +/ 0,2 C. The setpoint shift works in this mode only when the controller is in the comfort mode. Table 15: Function selection room temperature controller 2 = on the left: current setpoint, on the right: setpoint shift 2 The following table shows the relevant communication objects: Type Name DPT Usage Room Status temperature Must be connected with the current temperature temperature controller Room Set point Must be connected with the current set point temperature controller temperature Set point shift via 1 Bit object Room temperature controller Set point shift 1 Bit Must be connected with the object for the set point shift of the room temperature controller. Set point shift via basic set point Room temperature controller Basic set point 2 Byte Must be connected with the object basic set point of the room temperature controller. This object sends directly a new set point, which is calculated of the current set point and the sending difference of +/ 0,2 C. Table 16: Communication objects room temperature controller 37
38 6.5.2 Function selection: Room temperature controller with HVAC mode The setpoint can be shifted via 1 bit objects as well as a new basic comfort value can be entered via a 2 Byte object. The presentation and function is the same in the app in both cases. In addition, the modes can be switched via the HVAC mode. Adjust the setpoint on Description Representation in the App Setpoint shift with 1 Bit object Base setpoint The setpoint is shifted via a normal 1 Bit object, which changes the setpoint according tot he setting sin the room temperature controller. The setpoint is set as new base setpoint. The change per press is adjusted to +/ 0,2 C. The setpoint shift works in this mode only when the controller is in the comfort mode. Table 17: Function selection room temperature controller with HVAC 1 = current temperature 3 2 = on the left: current setpoint, on the right: setpoint shift 3 = Selection of the operating modes, green = active 1 2 The following table shows the relevant communication objects: Type Name DPT Usage Room temperature controller Status temperature Must be connected with the current temperature Room temperature controller Room temperature controller Set point temperature Must be connected with the current set point HVAC Mode Must be connected with the object HVAC mode for switching the operating modes of the controller Set point shift via 1 Bit object Room temperature controller Set point shift 1 Bit Must be connected with the object for the set point shift of the room temperature controller. Set point shift via basic set point Room temperature controller Basic set point 2 Byte Table 18: Communication objects room controller with HVAC Must be connected with the object basic set point of the room temperature controller. This object sends directly a new set point, which is calculated of the current set point and the sending difference of +/ 0,2 C. 38
39 6.5.3 Function selection: Room temperature controller with HVAC modeand Status The function selection "Room temperature controller with HVAC mode and status" is equal to the function selection under Function selection: Room temperature controller with HVAC mode described. The function selection is only extended to the object HVAC status, which returns the current status of the controller. The display of the currently selected mode is displayed in this case according to the output of the status object. Therefore, it is in this case also possible that the display of the currently active mode is slightly late, depending on the internal processing in the room controller. The function is completely identical to the under Function selection: Room temperature controller with HVAC mode described, only the following communication object is in addition to: Type Name DPT Usage Raumtemperaturregler controller HVAC State ohne must be connected to the HVAC state of the Table 19: Communication object room temperature controller with HVAC mode & HVAC state The HVAC state is compatible with all MDT devices and is evaluated as follows: Bit DPT HVAC State Hex Value 0 Comfort 1=Comfort 0x01 1 Standby 1=Standby 0x02 2 Night 1=Night 0x04 3 Frost/Heat 1= Frost/Heat 0x08 protection protection 4 5 heating/cooling 0=Cooling/ 1= 0x20 Heating 6 7 Frost alarm 1=Frost alarm 0x80 Table 20: Evaluation DPT HVAC state 39
40 6.6 Function type: Scenes Scenes allow controlling all trades various functions. The scene function can be activated with the ability to store as well as without. Data point type Description Representation in the App Scene number Scene control Table 21: Function type scenes In this function, only the calling of scenes is enabled. The scene which sould be called can be specified separately. In this function, a short press calls the scene and a long press savest he scene with the new values. The scene which sould be called can be specified separately. The following chart shows the relevant communication objects: Type Name DPT Usage Szenes Activate scene Calling a scene sends the adjusted scene number Szenes Save scene Calling and saving scenes, sends at a short press the adjusted scene number and at a long press the saving command for the adjusted scene number Table 22: Communication objects function type scene 40
41 6.7 Function type: Multimedia The function type multimedia enables the control of multimedia gateways, such as the SCN MMG The multimedia control can be adjusted via the function selection in terms of functionality Funktion selection: Multimedia control With the function selection Multimedia control 4 objects are displayed and the user has the option to select the functions of play, stop, pause and track forward / back. The view in the app is as follows: Play Stop Pause Track forward/back The following table shows the relevant communication objects: Type Name DPT Usage Multimedia Play Must be connected with the Start/Stop functionality of the controlled device Multimedia Pause Must be connected with the Pause functionality of the controlled device Multimedia Stop Must be connected with Start/Stop functionality of the controlled device Multimedia Title selection Sends a zero for track back and a one for track forward Table 23: Communication objects function type multimedia Function selection: Multimedia control with volume With the function selection Multimedia control 4 objects are displayed and the user has the option to select the functions of play, stop, pause and track forward / back as well as volume +/ The view in the app is as follows: Play Stop Pause Track forward/back Volume +/ 41
42 The following table shows the relevant communication objects: Type Name DPT Usage Multimedia Play Must be connected with the Start/Stop functionality of the controlled device Multimedia Pause Must be connected with the Pause functionality of the controlled device Multimedia Stop Must be connected with Start/Stop functionality of the controlled device Multimedia Title selection Sends a zero for track back and a one for track forward Multimedia Volume Sends a zero for reducing volume and a one for increasing volume Table 24: Communication objects function type multimedia control with volume Function selection: Volume The function selection volume offers an easy function for controlling the volume. The view in the app is as follows: The following table shows the relevant communication objects: Type Name DPT Usage Multimedia Volume Sends a zero for reducing volume and a one for increasing volume Table 25: Communication objects function type volume 42
43 43 Technical Manual VisuControl Easy VC EASY Function type: Status The function type status enables the representation of different functions. The status functions are the confirmation of certain switching states and can not send any values. Subsequently, all available status functions are tabulated: Functional description Communication object description Data point type Description Representation in the App Name DPT Usage DPT 00 Switching 1 Bit DPT 01 Locking/ Unlocking DPT 02 Up/Down DPT 03 Open/Closed DPT 04 Open/Closed (garage) DPT 05 Open/Closed (window) DPT 06 On/Off (socket) Function for displaying of normal switching functions, function can be inverted Function for displaying of a locking process, function can be inverted Function for displaying of a driving function, function can be inverted Function for displaying whether doors/ windows/ garages are closed, function can be inverted Function for displaying whether garage doors are closed, function can be inverted Function for displaying whether windows are closed, function can be inverted Function for displaying whether sockets are switched, function can be inverted Switch On/Off Must be connected with state of switching actuator Lock/Unlock Must be connected with state of locking process Up/Down Must be connected with state of the driving function Open/Close Must be connected with state of door/window contact Open/Close Must be connected with state of garage door Open/Close Must be connected with state of indow contact Switch On/Off Must be connected with state of switching actuator
44 44 Technical Manual VisuControl Easy VC EASY.01 DPT 07 LED Display DPT 09 Unsigned value (0..255) DPT 10 Signed value ( ) DPT 11 Percent unsigned DPT 12 Percent signed DPT 15 Unsigned value ( ) DPT 16 Decimaldifference DPT 17 Floating point number Function for showing a switching state in LED design, Color of the LED can be selected as Red/Green or blue and off, function can be inverted Function for displaying of contiuous values (0..255) Function for displaying of contiuous, signed values ( ) LED disply Must be connected with the state of the monitored function Decimal unsigned (0..255) Decimal signed ( ) Function for showing percental values Unsigned percent (0..100%) Function for displaying of contiuous, signed percental values ( %) Function for displaying of 2 Byte, unsigned counts, Unit can be selected arbitrary Function for displaying count differences, Unit can be selected arbitrary Function for displaying of floating point values as current measurement, voltage, temperature, Unit can be selected arbitrary Signed percent ( %) Decimal ( ) Decimal difference ( ) Floating point number Must be connected with the state of the monitored function Must be connected with the state of the monitored function Must be connected with the state of the monitored function Must be connected with the state of the monitored function Must be connected with the state of the monitored function Must be connected with the state of the monitored function 9.* Must be connected with the state of the monitored function; DPT depends to the monitored function
45 45 Technical Manual VisuControl Easy VC EASY.01 DPT 18 RGB Function for displaying of the current color RGB Must be connected with the 3 Byte state of a RGB actuator DPT 19 Unsigned value DPT 20 Signed value DPT 21 Floating point number Function for displaying of 4 Byte, unsigned counts; Unit can be selected arbitrary Function for displaying of 4 Byte, signed counts; Unit can be selected arbitrary Function for displaying of 4 Byte, floating point numbers; Unit can be selected arbitrary Decimal unsigned Must be connected with the state of the monitored function Dezimal signed Must be connected with the state of the monitored function Floating point number 14.* Must be connected with the state of the monitored function, DPT depends to the monitored function DPT 22 String Function for displaying strings String Must be connected with the state of the monitored function DPT 23 HVAC Status DPT 24 HVAC Mode DPT 25 RHCC Status Table 26: Overview function type state Function for displaying of the HVAC state of room temperature controller Function for displaying of the HVAC mode of room temperature controller Function for displaying of the RHCC state of room temperature controller HVAC Status without Evaluation: have a look at Function selection: HVAC Mode Muts be connected with the HVAC mode of a room temperature controller RHCC Status Muts be connected with the RHCC mode of a room temperature controller
46 46 Technical Manual VisuControl Easy VC EASY Function type: Other The function type "Other" is a kind of collecting function for all functions, which can be accessed through the app. Subsequently, all available functions are tabulated, which are sorted in the function type Other : Functional description Communication object description g Data point type Description Representation in the App Name DPT Usage The data point types DPT DPT 00 to 06 can be implemented in a "two button", "One button toggle" or "Ob ne button send value". The icon, which reflects the status of each function is different for each function, and is shown separately for this. In the presentation format " One button toggle " always the complementary value of the status is displayed on the control button, so the action is executed with the next keystroke. Two buttons: The communication object is shown for every data point type seperately One button toggle: Value toggles with every switching One button send value: DPT 00 Switching 1 Bit DPT 01 Lock/Unlock Value is constant On or Off Function for normal switching functions Switch On/Off Must be connected with function, which should be switched, and the state of the function Function for locking/unlocking Lock/Unlock Must be connected with function, which should be locked, and the state of the function
47 47 Technical Manual VisuControl Easy VC EASY.01 DPT 02 Up/Down DPT 03 Open/Close DPT 04 Open/Close (garage) DPT 05 Open/Close (window) DPT 06 On/Off (socket) Function for driving Shutter/Blinds Up/Down Must be connected with function, which should be driven and the state of the function Function for driving all trades Open/Close Must be connected with function, which should be driven and the state of the function Function for driving garage doors Open/Close Must be connected with function, which should be driven and the state of the function Function for driving windows Open/Close Must be connected with function, which should be driven and the state of the function Function for switching sockets Switch On/Off Must be connected with function, which should be switched, and the state of the function DPT 07 Dimmer step DPT 08 Shutter step Function for sending relative dim commands, step size per keystroke must be adjusted in the dimming actuator Function for sending relative drive commands, step size per keystroke must be adjusted in the shutter actuator Dimming relatively drive blinds relatively Must be connected with the relative dimming of the dim channel Must be connected with the step object of the shutter channel
48 48 Technical Manual VisuControl Easy VC EASY.01 DPT 09 Unsigned value (0..255) DPT 10 Signed value ( ) DPT 11 Percent unsigned value Function for sending continuous, unsigned values (0..255) Function for sending continuous, signed values ( ) Presentation format: Eingabefeld Eine Taste mit festem Wert Decimal unsigned (0..255) Decimal signed ( ) Function for sending percental values Unsigned percent (0..100%) Slider DPT 12 Percent signed value Function for sending percental signed values ( %) Signed percent ( %) DPT 13 Call scene DPT 14 Save scene This function can only call scenes. The calling scene can be adjusted separately. Function calls scenes with a short keystroke and saves scenes with a long keystroke. The calling scene can be adjusted separately. Scene number Scene control Must be connected with function, which should be controlled and the state of the function Must be connected with function, which should be controlled and the state of the function Must be connected with function, which should be controlled and the state of the function Must be connected with function, which should be controlled and the state of the function Calling scenes, sends the adjusted scene number Calling scenes, sends the adjusted scene number by a short keystroke, sends the saving command by a long keystroke
49 49 Technical Manual VisuControl Easy VC EASY.01 DPT 15 Unsigned value ( ) DPT 16 Decimaldifference DPT 17 Floating point number Function for sending 2 Byte unsigned counts Presentation format: Input field Function for sending 2 Byte count differences One button with fixed value Decimaldifference ( ) Function for sending current value, voltage value or temperature value Slider DPT 18 RGB Function for setting RGB colors Presentation format: Three RGB bars: One button with fixed value: Decimal ( ) Floating point number Must be connected with function, which should be controlled and the state of the function Must be connected with function, which should be controlled and the state of the function 9.* Must be connected with function, which should be controlled and the state of the function RGB Must be connected with 3 Byte object of the RGB actuator, which sould be controlled. Object of the 3 RGB bars must additional connected to the 3 Byte RGB state.
50 50 Technical Manual VisuControl Easy VC EASY.01 DPT 19 Unsigned value DPT 20 Signed value DPT 21 Floating point number Function for sending of 4 Byte unsigned counts Presentation format: Input field Decimal unsigned Must be connected with function, which should be controlled and the state of the function Function for sending of 4 Byte signed counts One button with fixed value Decimal signed Must be connected with function, which should be controlled and the state Slider of the function Function for sending 4 Byte floating point numbers DPT 22 String Function for sending strings Presentation format: Input field Floating point number 14.* Must be connected with function, which should be controlled and the state of the function String Must be connected with function, which should be controlled One button with fixed value DPT 24 HVAC Mode Table 27: Overview function type "Other" Function for switching the operating modes in the room temperature cobntroller HVAC Mode Must be connected with the HVAC Mode of the room temperature controller
51 7 Index 7.1 List of figures Figure 1: Overview... 4 Figure 2: Exemplary circuit diagram... 5 Figure 3: Hardware module... 6 Figure 4: Local settings... 8 Figure 5: Internal access... 9 Figure 6: External access Figure 7: App Settings external connection# Figure 8: App View: Sort after functions Figure 9: App View: Sort after areas Figure 10: Approach to project planning Figure 11: Menu General Figure 12: manual IP Configuration Figure 13: Menu formatting of the areas Figure 14: Menu formatting of the function types Figure 15: Menu Function selection Figure 16: Submenu function Figure 17: Area allocation Figure 18: Function allocation Figure 19: Visibility of functions Figure 20: Sorting of the functions Figure 21: Selection of the status logic Figure 22: Status logic Figure 23: Area allocation Figure 24: Logical connection & Function name Figure 25: Visibility of the status logic Figure 26: Sorting of the function Figure 27: Menu weather data Figure 28: Weather data Figure 29: Function type Switching
52 7.2 List of tables Table 1: Function selection switching Table 2: Function selection light Table 3: Function selection Dimmer Table 4: Communication objects dimmer Table 5: Communication object individual objects RGB Table 6: Communication object RGB combined object Table 7: Communication objects HSV individual objects Table 8: Communication objects HSV combined objects Table 9: Function selection Shutter/Blinds Table 10: Communication object Shutter/Blinds function Table 11: Function selection Shutter/Blinds with height position Table 12: Communication objects shutter/blinds with height position Table 13: Function selection shutter/blinds with height position and slats Table 14: Communication objects shutter/blinds with absolute height and slats Table 15: Function selection room temperature controller Table 16: Communication objects room temperature controller Table 17: Function selection room temperature controller with HVAC Table 18: Communication objects room controller with HVAC Table 19: Communication object room temperature controller with HVAC mode & HVAC state Table 20: Evaluation DPT HVAC state Table 21: Function type scenes Table 22: Communication objects function type scene Table 23: Communication objects function type multimedia Table 24: Communication objects function type multimedia control with volume Table 25: Communication objects function type volume Table 26: Overview function type state Table 27: Overview function type "Other"
53 8 Attachment 8.1 Statutory requirements The above described devices must not be used with devices, which serve directly or indirectly the purpose of human, health or lifesaving. Further the devices must not be used if their usage can occur danger for humans, animals or material assets. Do not let the packaging lying around careless, plastic foil/ bags etc. can be a dangerous toy for kids. 8.2 Routine disposal Do not throw the waste equipment in the household rubbish. The device contains electrical devices, which must be disposed as electronic scrap. The casing contains of recyclable synthetic material. 8.3 Assemblage Risk for life of electrical power! All activities on the device should only be done by an electrical specialist. The county specific regulations and the applicable EIB directives have to be observed. 53
54 8.4 Sample projects Both sample projects can be downloaded using the provided links and can be downloaded without any further settings in your device. Only the communication objects must be connected to the corresponding communication objects. Sample can be downloaded at Example 1 (easy) Example 1 shows the VisuControl Easy as it could be set for a single family home with a few KNX functions. Eaxmple 1 can be downlaoded via the following link: Sample project 1 is optimized for sorting after areas Example 2 (advanced) Example 2 shows the VisuControl Easy as it could be set for a single family home with a extended KNX functions. Eaxmple 2 can be downlaoded via the following link: Sample project 2 is optimized for sorting after functions. 54
55 VisuControl Easy N MDT Object server VisuControl Easy, MDRC Version VC-EASY.01 Object server with iphone/ipad APP 2SU MDRC The MDT VisuControl Easy object server is used for the visualisation of the current building status and to control building functions. The visualisation is displayed only on iphone or ipad with the free VisuControl for KNX app. 10 iphones/ipads can establish a connection to the object server simultaneously. Additionally the app has a demo mode for presentation without connected object server. The visualisation can be arranged individually in rooms, zones or groups. Within these ranges at most 250 datapoints can be associated (50 functions, each with up to 5 datapoints). After the parameterisation the graphical user interface is created automatically. The object server can be also used as programming interface for the ETS. External power supply or Power over Ethernet (PoE) is possible. The MDT Objects server is a modular installation device for fixed installations in dry rooms. It fits on DIN 35mm rails in power distribution boards or closed compact boxes. For project design and commissioning of the MDT Object server it is recommended to use the ETS4 or later. Please download the application software at VC-EASY.01 Production in Germany, certified according to ISO 9001 VisuControl for KNX app (with demo function) available in the App Store Visualization and switching, dimming, shutter/blind control Fast commissioning with ETS Graphical user interface is created automatically Individual arrangement in rooms, zones or groups Possible to visualize up to 50 functions External power supply or PoE required 2SU modular installation device for DIN 35mm rails Integrated bus coupling unit 3 years warranty Tel.: Fax: [email protected] Stand: 0514 DIN EN ISO 9001 TAW Cert Zert.Nr
56 VisuControl Easy N Technical Data VC-EASY.01 Interface KNX/Ethernet Max number of datapoints 250 Permitted wire gauge Screw terminal KNX busconnection terminal Power Supply 0,5-4,0mm² solid core 0,5-2,5mm² finely stranded 0,8mm Ø, solid core 12-24VAC / 12-30VDC / PoE Power consumption < 0,8W Operation temperature range 0 to + 45 C Enclosure IP 20 Dimensions MDRC (Space Units) 2SU Examplary circuit diagram VC-EASY.01 Tel.: Fax: [email protected] Stand: 0514 DIN EN ISO 9001 TAW Cert Zert.Nr
How To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
Tebis application software
Tebis application software Input products / ON / OFF output / RF dimmer Electrical / Mechanical characteristics: see product user manual Product reference Product designation TP device RF devices WYC81xQ
B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted 7566359x, 7566459x, 7566559x
B.IQ push button 3-5gang with room Product name: Design: ETS search path: B.IQ push button 3-, 4-, 5gang with room thermostat and display V2 Flush-mounted Push button / B.IQ / B.IQ push button xgang with
IDDERO HOME SERVER. Quick start guide. www.iddero.com 150302-02
IDDERO HOME SERVER Quick start guide www.iddero.com 150302-02 TABLE OF CONTENTS 1 INTRODUCTION... 3 2 IDDERO CONFIGURATION SOFTWARE... 3 2.1 Installation and First Steps...3 3 IDDERO HOME SERVER CONFIGURATION...
Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted 756627xx, 756637xx, 756657xx
756627xx, 756637xx, 756657xx Documentation Product name: Push button 2-, 3-, 5- gang RTR + display Design: UP (flush-mounting type) ETS search path: Push button / Push button xgang / Push button xgang
Technical Manual MDT Rain sensor
9/2012 Technical Manual MDT Rain sensor SCN-RS1R1.01 Technical Manual Rain sensor SCN RS1R1.01 1.1. Settings at the ETS Software Selection at the product database: Manufacturer: MDT Technologies Product
Inwall 4 Input / 4 Output Module
Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...
Inwall Room Temperature Unit
Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall
KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems
KNX Gateway Light-Control R User manual-ver.1 LC-IPGW-001 Intelligent Installation Systems Contents 1. Summary ---------------------------------------------------------------------------------------------------------------------
PRODUCT MANUAL. InZennio Z38i. KNX Touch Panel ZN1VI-TP38i. Program version: 2.2 Manual edition: a
PRODUCT MANUAL InZennio Z38i KNX Touch Panel ZN1VI-TP38i Program version: 2.2 Manual edition: a INDEX Document updates... 3 1. Introduction... 4 1.1. InZennio Z38i... 4 1.2. Installation... 5 2. Configuration...
Glass sensor 2gang with room thermostat Glass sensor 3gang with room thermostat
KNX/EIB Product documentation Glass sensor 2gang with room thermostat Glass sensor 3gang with room thermostat Issue: 16.01.2009 65750120 Page 1 of 240 KNX/EIB Product documentation Content 1 Product definition...
ABB i-bus EIB Logic Module LM/S 1.1
Product Manual ABB i-bus EIB Logic Module LM/S 1.1 Intelligent Installation System Contents page 1 General... 3 1.1 About this manual... 3 1.2 Product and functional overview... 3 2 Device technology...
Mobile Surveillance. User Manual
Mobile Surveillance User Manual Contents 1 Network Configuration... 1 1.1 Access Device via WLAN... 1 1.2 Access Device via 3G Network... 1 2 By Phones with iphone OS... 2 2.1 Installation Instruction...
Passion for Innovation
Passion for Innovation A Complete Solution Hardware All the Alveo servers are designed and optimized to manage the home automation system. They arebuilt for continuous operation with fanless processing
The ABB i-bus KNX Room Master Concept Your first step into the KNX world
The ABB i-bus KNX Room Master Concept Your first step into the KNX world The Room Master Concept 1 New Step 1,000 New Options You specialize in installing electrical systems. With the ABB Room Master,
USER GUIDE FOR ANDROID DEVICES
USER GUIDE FOR ANDROID DEVICES Compatibility: Android 2.3 or higher 1. Overview... 4 2. Install and Set Up... 4 2.1. Download Emtec Connect App... 4 2.2. Connect your Wi-Fi HDD to your smartphones/ tablets
KNX IP INTERFACE IN00A02IPI. Operating and installation manual
KNX IP INTERFACE IN00A02IPI Operating and installation manual Product: IN00A02IPI Description: KNX IP INTERFACE Document: Version: 1.4 Date: 02/09/2014 www.eelectron.com, [email protected] 1/8 Application
IX Support Tool Setting Manual
IX System IP network-compatible intercom IX Support Tool Setting Manual Software version 2.0.0.0 or later Before configuring and using the system, read Setting Manual and Operation Manual (PDF) carefully.
ABB i-bus KNX i-bus Tool Product Information
ABB i-bus KNX i-bus Tool Product Information A professional Service Tool for System Integrators ABB presents a fully new and innovative software concept with the i-bus Tool. It supports system integrators
Shutter Actuator, 8-fold, 230 V AC, MDRC JA/S 8.230.1, GH Q631 0063 R0111. ABB i-bus EIB / KNX
, GH Q631 0063 R0111 2CDC 071 238 F0003 For controlling a maximum of eight independent 230 V AC shutter or sunblind drives via ABB i-bus including the functions Up/Down, Step/Stop, Move to position, Sun
Push button 3gang standard flush-mounted 751633xx
Documentation Product name: Push button 3gang standard Design: device (up) ETS search path: Push button / Push button 3gang / Push button 3gang standard Functional description: The push button 3gang standard
DALIX PROGRAMMING MANUAL. Gateway KNX-DALI V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 [email protected]
Gateway KNX-DALI DALIX V1.0 PROGRAMMING MANUAL Parque Tecnológico de Asturias, Parcela 50, 33428 Llanera Asturias - Spain Tel (+34) 985 118 859 Fax (+34) 984 283 560 [email protected] www.ingeniumsl.com
Unica for KNX system 226
Unica for KNX system 6 P117504 Greater flexibility and comfort, better energy efficiency with KNX More and more electronic appliances are needed for modern comfortable homes that contain everything from
Client applications are available for PC and Mac computers and ios and Android mobile devices. Internet
Introduction to OpenVPN 1 - Introduction to OpenVPN The AN-300-RT-4L2W router features a built-in OpenVPN server for secure, easily configured access to the network from the Internet using devices with
IDDERO HCx-KNX TOUCH PANELS. Quick start guide. www.iddero.com 130125-02
IDDERO HCx-KNX TOUCH PANELS Quick start guide www.iddero.com 130125-02 TABLE OF CONTENTS 1 INTRODUCTION... 3 2 IDDERO CONFIGURATION SOFTWARE... 3 2.1 Installation and First Steps...3 3 TOUCH PANEL CONFIGURATION...
ABB i-bus KNX Fan Coil Controller FC/S 1.1
Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation
Application Unit, MDRC AB/S 1.1, GH Q631 0030 R0111
, GH Q631 0030 R0111 SK 0010 B 98 The application unit is a DIN rail mounted device for insertion in the distribution board. The connection to the EIB is established via a bus connecting terminal at the
Light scene push button 8gang comfort flush-mounted 751688xx
751688xx Documentation Product name: Light scene push button 8gang comfort Design: flush-mounting type (Up) ETS search path: Push button / Push button general / Light scene push button 8gang comfort Functional
Quick Start Guide. Cisco SPA232D Mobility Enhanced ATA
Quick Start Guide Cisco SPA232D Mobility Enhanced ATA Package Contents Analog Telephone Adapter Ethernet Cable Phone Cable Power Adapter Quick Start Guide Product CD-ROM Welcome Thank you for choosing
ZME_WALLC-S Z-Wave Secure Wall Controller
ZME_WALLC-S Z-Wave Secure Wall Controller Firmware Version : 1.0 Quick Start S This device operates as Z-Wave sensor in two modes: the normal control mode (daily use) or in management mode for setup. Pushing
iridium for Weinzierl KNX IP BAOS
iridium for Weinzierl KNX IP BAOS Fast Start: Connection Setting Manual for KNX/EIB bus through IP Interfaces of Weinzierl KNX IP BAOS Review of iridium Software Package for KNX/EIB: iridium turns your
Quick-Start Guide. Remote Surveillance & Playback SUPER DVR MONITORING SOFTWARE. For use on Q-See s QSDT series of PC Securitiy Surveillance Cards
Quick-Start Guide SUPER DVR MONITORING SOFTWARE Remote Surveillance & Playback For use on Q-See s QSDT series of PC Securitiy Surveillance Cards 2 CONFIGURING ROUTER FOR REMOTE ACCESS REMOTE SURVEILLANCE
APPLICATION NOTE. Ethernet Configuration Guide for D-500 D-700
Tel: +90-216 466 84 60 Fax: +90-216 364 65 65 [email protected] http://www.datakom.com.tr APPLICATION NOTE Ethernet Configuration Guide for D-500 D-700 PRODUCTS AFFECTED: D-500 / D-700 WRITTEN BY:
ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1
Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................
IntesisBox KNX Mitsubishi Heavy Industries AC
IntesisBox KNX Mitsubishi Heavy Industries AC Gateway for integration of Mitsubishi Heavy Indsutries (MHI) Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB)
LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 [email protected]
Integrations LGAC-KNX V1.0 PROGRAMMING MANUAL Parque Tecnológico de Asturias, Parcela 50, 33428 Llanera Asturias - Spain Tel (+34) 985 118 859 Fax (+34) 984 283 560 [email protected] www.ingeniumsl.com
CX Series. Video Recording Server. Quick Start Guide CX784 / CX788 / CX7816. Version 1.05.00
CX Series Video Recording Server CX784 / CX788 / CX7816 Quick Start Guide Version 1.05.00 Contents 1.Introduction...1 1.1.Packages Contents...1 1.2.Hardware Features...2 1.3.Functional Features...4 1.4.Hard
domovea installer manual tebis
domovea installer manual tebis SUMMARY SUMMARY Page 1. INTRODUCTION... 3 1.1 PURPOSE OF THE DOCUMENT... 3 2. GENERAL DESCRIPTION... 4 2.1 SYSTEM OVERVIEW... 4 2.2 OVERVIEW OF THE SYSTEM... 4 2.3 THE DOMOVEA
Application software. IP/KNX Interface Electrical / Mechanical characteristics : see product information. Order number. TP device RF devices
Application software IP/KNX Interface Electrical / Mechanical characteristics : see product information Order number Product designation Application software ref. TP device RF devices TYF120 IP/KNX Interface
FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7
FAQs Conserve package Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7 FAQs Gateway Can I have someone install my system for me? If you are concerned
KNX IP Interface. Operating and installation manual
KNX IP Interface Operating and installation manual Application The KNX IP Interface can be used as an interface for accessing the KNX/EIB via IP, replacing an RS232 or USB interface. It has an external
LOGO! LOGO! App V.10. LOGO! app 1. Making basic settings and establishing a connection to LOGO! Using the device overview 3. Creating controls 4
LOGO! app 1 Making basic settings and establishing a connection to LOGO! 2 LOGO! Using the device overview 3 Creating controls 4 Settings and project information 5 Operating Manual 04/2016 A5E38071463-AA
DOMUSBOX. User guide. Index
DOMUSBOX User guide Index Introduction... 2 1. Installing SEAV DOMUS... 4 1.1 Activating DomusBox... 4 1.2Drawing the environments in DomusWeb... 5 1.3Connecting DomusBox to the devices...9 1.4Configuration
iridium for KNX/EIB Fast Start: Connection Setting Manual for KNX/EIB equipment
iridium for KNX/EIB Fast Start: Connection Setting Manual for KNX/EIB equipment Review of iridium Software Package for KNX/EIB: iridium turns your iphone/ipod/ipad or Windows device into a KNX system control
Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A
COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850
R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement
I/Q Modulation Generator Supplement The following description relates to the Operating Manuals, version 03 of R&S AFQ100A, and version 01 of R&S AFQ100B. It encloses the following topics: LXI features,
USER MANUAL FOR DRIVER RTI & HDL. Driver User Guide January 2016. Index. 1 Overview... 3 2 Driver Option... 3
Driver User Guide January 2016 Index 1 Overview... 3 2 Driver Option... 3 1 3 Supported IP Gateway Types... 3 4 Supported data Types.....4 5 Configure System Settings... 5 6 Configure General Settings...
USER GUIDE FOR ANDROID DEVICES
USER GUIDE FOR ANDROID DEVICES Compatibility: Android 2.3 or higher 1. Overview... 4 2. Install and Set Up... 4 2.1. Charge your Power Connect... 4 2.2. Charge your smartphone battery with Power Connect...
RadioRA 2 (QS) Lighting and Climate Control. g! 5.4 Fan Controller: g! 6.4.200 RadioRA2 Inclusive Software v5.0.8 or newer
Manufacturer: Model Number(s): Minimum Core Module Version: Comments: Lutron Document Revision Date: 8/5/2013 OVERVIEW AND SUPPORTED FEATURES Integration Note RadioRA 2 (QS) Lighting and Climate Control
Operating instructions. RCD flat 4-fold, 6-fold
Operating instructions 1. Safety instructions Electrical equipment must be installed and fitted by qualified electricians only. Observe the current accident prevention regulations. Failure to observe the
NETVIGATOR Wireless Modem Setup Guide. (TG789Pvn)
NETVIGATOR Wireless Modem Setup Guide (TG789Pvn) Configure the NETVIGATOR Wireless Modem Make sure that system meets the following requirement prior to NETVIGATOR Wireless Modem usage: - Subscribers who
USER GUIDE. Web Interface
USER GUIDE Web Interface 1. Overview... 4 2. Install and Set Up... 4 2.1. Charge your Wi-Fi HDD... 4 2.2. For Mac users... 5 2.3. Connect your Wi-Fi HDD to your computer (no Internet connection required)...
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
Wifi Bridge Manual of operation
Wifi Bridge Manual of operation (Hardware V 2.0, Firmware V 1.3) 2 Wifi Bridge Thank you for choosing the Wifi Bridge. The Wifi Bridge makes it possible to control lighting, electric blinds as well as
Application program usage. Functional description. Note. Note. instabus EIB Application Program Description. August 2009. 12 CO IP-Interface 720001
Application program usage Product family: Product type: Manufacturer: System devices IP-Interface Siemens Name: IP Interface N148/21 Order-No.: 5WG1 148-1AB21 Name: IP Interface N148/22 Order-No.: 5WG1
Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB
Product Manual ABB i-bus KNX IP Interface IPS/S 2.1 Intelligent Installation Systems ABB This manual describes the function of the IP Interface IPS/S 2.1 with the application program IP Interface. Subject
Networking Guide Redwood Manager 3.0 August 2013
Networking Guide Redwood Manager 3.0 August 2013 Table of Contents 1 Introduction... 3 1.1 IP Addresses... 3 1.1.1 Static vs. DHCP... 3 1.2 Required Ports... 4 2 Adding the Redwood Engine to the Network...
PRODUCT MANUAL IRSC. IRSC-Plus. Air-Conditioning controller ZN1CL-IRSC. Program version: 5.14 Manual edition: 5.14_a
PRODUCT MANUAL IRSC IRSC-Plus. Air-Conditioning controller ZN1CL-IRSC Program version: 5.14 Manual edition: 5.14_a INDEX Document updates... 3 1. Introduction... 4 1.1. IRSC controller... 4 1.2. Installation...
C n o t n e t n e t n s
Preface Thank you for choosing our product, for a better understanding of the product, we recommend you read the instruction and safety information before use. Notice: This user manual is an operation
SOLAROX RGB-Master Pro LAN. RGB-Master Pro LAN. Network-compatible RGBW Controller -
RGB-Master Pro LAN Network-compatible RGBW Controller - Seite 1 / 13 Introduction Thank you for purchasing to the Solarox RGB-Master Pro LAN. The Solarox RGB-Master Pro LAN is a highly-developed, network-compatible
User manual BS1000 LAN base station
1/18 Contents 1.Introduction 2.Package of the LAN Base Station 3.Software installation 4.Installation of the Receiver 5.Sensor operation 6.Software operation Introduction The BS1000 is a receiver station
Mobile Android App User Guide
Mobile Android App User Guide Mobile Android App User Guide Copyright 2012 icontrol Networks, Inc. All rights reserved. No reproduction in whole or in part without prior written approval. icontrol Networks,
Wireless-N. User Guide. PCI Adapter WMP300N (EU) WIRELESS. Model No.
2,4 GHz WIRELESS Wireless-N PCI Adapter User Guide Model No. WMP300N (EU) Copyright and Trademarks Specifications are subject to change without notice. Linksys is a registered trademark or trademark of
Web: www.stp.hu; www.logipix.eu; www.walkdvr.com
StP Technical Development Ltd. version: 1 Contact: Address: 11-13. Késmárk st., 1158 Budapest, Hungary Phone: +36 1 410-0556; +36 20 480-5933 Fax: +36 1 414-0913 E-mail: [email protected] Technical support:
Rako Lighting Driver. For use with: Driver software written and provided by:
Rako Lighting Driver For use with: Driver software written and provided by: Introduction This document is a guide to integrating a Rako Lighting system with an RTI control system, via a Rako Ethernet bridge.
PRONET WEB SERVER. INSTRUCTIONS FOR INSTALLATION AND USE English. Version 01/15 Ident no. 50950129
PRONET WEB SERVER INSTRUCTIONS FOR INSTALLATION AND USE English EN Version 01/15 Ident no. 50950129 Table of Contents 1. About these instructions 3 2. Important information for your safety 4 2.1. Intended
IDDERO HCx-KNX TOUCH PANELS. User Guide. www.iddero.com 130122-02
IDDERO HCx-KNX TOUCH PANELS User Guide www.iddero.com 130122-02 TABLE OF CONTENTS 1 INTRODUCTION... 3 2 OVERVIEW... 3 2.1 System Components... 3 2.2 Basic Operation... 4 2.3 Install Mode... 5 3 USER INTERFACE...
SNMP Web Management. User s Manual For SNMP Web Card/Box
SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...
Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB
, GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well
HWg-STE HWg-STE PoE MANUAL
HWg-STE HWg-STE PoE MANUAL www.hw-group.com Page 2 HWg-STE connectors LED indicators Green: Power & Mode Yellow: Link & Activity SENSORS S1 and S2 ports for connecting temperature or humidity sensors.
Network Video Recorder
Network Video Recorder XC-4CH-NVR-1TB and XC-8CH-NVR-2TB Username: admin Password: 12345 Quick Operation Guide XC-4CH-NVR-1TB and XC-8CH-NVR-2TB quick guide TABLE OF CONTENTS NVR Pre-Installation... 2
SOHO 6 Wireless Installation Procedure Windows 95/98/ME with Internet Explorer 5.x & 6.0
SOHO 6 Wireless Installation Procedure Windows 95/98/ME with Internet Explorer 5.x & 6.0 Before You Begin Before you install the SOHO 6 Wireless, you must have: A computer with a 10/100BaseT Ethernet card
Light-Manager Air Quickstart Guide
media Light-Manager Air Quickstart Guide Overview and scope of delivery Thank you for choosing the Light-Manager Air. The Light-Manager is the control center for your wireless home automation. For this
VPN Configuration Guide. AVM FRITZ!Box
VPN Configuration Guide AVM FRITZ!Box 2013 equinux AG and equinux USA, Inc. All rights reserved. Under copyright law, this manual may not be copied, in whole or in part, without the written consent of
ProSAFE 8-Port and 16-Port Gigabit Click Switch
ProSAFE 8-Port and 16-Port Gigabit Click Switch Model GSS108E and GSS116E User Manual March 2015 202-11520-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products.
Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.
Data logger Installation and operating instructions SOREL Connect Read carefully before installation, commissioning and operation 1.1. - Specifications Description of data logger Electrical specifications:
Installation & Operations Manual
Installation & Operations Manual VoIP Command Center Made in the USA 3 Year Warranty N56 W24720 N. Corporate Circle Sussex, WI 53089 800-451-1460 262-246-4828 (fax) www.rathmicrotech.com www.area-of-refuge.com
EIB/KNX IP Interface with Power over Ethernet (PoE)
EIB/KNX IP Interface with Power over Ethernet (PoE) IP Interface between LAN and EIB/KNX bus (Quelle: EIBMARKT GmbH, Reference No.: N000401) Page 1 Application area The KNXnet/IP-Interface is used to connect
User Manual Network connection and Mobics Dashboard (MIS) software for Dryer Controller M720
User Manual Network connection and Mobics Dashboard (MIS) software for Dryer Controller Manual version : v1.00 Networking and MIS Manual Dryer controller Page 1 of 16 Document history Preliminary version
Servicom G.R.I.P. Enabling Global Push-to-Talk over BGAN and Fleet Broadband Version 01 30.09.11
Servicom G.R.I.P. Enabling Global Push-to-Talk over BGAN and Fleet Broadband Version 01 30.09.11 Contents 1 Overview... 1 2 Background... 1 3 Key Features... 2 4 Typical Users... 2 5 Benefits to BGAN and
Web Page Manual. GOLD RX, PX, CX, SD, Program Version 1.20
GB.webbE.0 Web Page Manual GOLD RX, PX, CX, SD, Program Version.0. General The air handling unit has a built-in web server that enables you to monitor, enter and change the settings in the air handling
IS SERIES. QuikStart Programming Guide. IP Network Direct System. Programming Videos
0215 IS SERIES IP Network Direct System QuikStart Programming Guide 1 4 GHI 2 ABC 5 JKL 3 DEF 6 MNO PRIVACY TRANSFER LIST SETTING 7 PQRS 8 TUV 9 WXYZ ZOOM 0 # WIDE Programming Videos ATTENTION: This is
Powerline 500 WiFi Access Point XWN5001 Installation Guide
Powerline 500 WiFi Access Point XWN5001 Installation Guide Technical Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on the label of your product
Product and Application Description
Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design
Movement/monitoring 1307/1.0 (6325xx)
/monitoring 1307/1.0 (6325xx) General In the following the device will be referred to as the movement detector. The movement block will only switch off when there is no more movement in front of the device
Quick Installation Guide. Overview. GULFSIP ATA-G1S Quick Installation Guide
Quick Installation Guide Overview This quick installation guide describes the objectives; organization and basic installation of the GULFSIP ATA-G1S VoIP Phone Adapter ( ATA in the following term). The
4. Rear View. Function Switches 1. Fixed IP 2. DHCP Floating IP 3. Auto IRIS (DC Driver LENS) 4. Fixed LENS (AES)
4. Rear View 5 1.STATIC IP 2.DHCP 3.DC IRIS Mini USB 1 2 3 4 5 6 1. ALM-RST 2. ALM-IN 3. ALM-OUT 4. GND 5. RS485-6. RS485 + 1 2 3 4 5 6 7 DC Power Input: DC Jackψ2.1, DC12V---0.5A or higher. LAN/WAN Network
Link Link sys E3000 sys RE1000
User Guide High Performance Extender Wireless-N Router Linksys Linksys RE1000 E3000Wireless-N Table of Contents Contents Chapter 1: Product Overview 1 Front 1 Top 1 Bottom 1 Back 2 Chapter 2: Advanced
Network Projector Operation Guide
Network Projector Operation Guide Table of contents Preparation...3 Connecting the projector with your computer...3 Wired connection... 3 Wireless connection (for selective models)... 4 QPresenter...7
Using the T&D Thermo App with TR-7wf Data Loggers
Using the T&D Thermo App with TR-7wf Data Loggers T&D Thermo The T&D Thermo App from T&D Corporation can be used to accomplish a variety of functions with the TR-7wf Series of Wi-Fi enabled wireless Data
Network Video Recorder Quick Operation Guide
Network Video Recorder Quick Operation Guide UD.6L0202B1119A01 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable
Bright House Networks Home Security and Automation Mobile Application. Quick Start Guide
Bright House Networks Home Security and Automation Mobile Application Quick Start Guide Home Security and Automation Mobile App User Guide Table of Contents Installing the Mobile Application... 4 Configuring
genie app and genie mobile app
genie app and genie mobile app User Manual 350 East Plumeria Drive San Jose, CA 95134 USA June 2012 202-10933-02 v1.0 2012 NETGEAR, Inc. All rights reserved No part of this publication may be reproduced,
USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6
KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly
AXIS Camera Station Quick Installation Guide
AXIS Camera Station Quick Installation Guide Copyright Axis Communications AB April 2005 Rev. 3.5 Part Number 23997 1 Table of Contents Regulatory Information.................................. 3 AXIS Camera
Skyworth LCD Video Wall Controller User Manual Please read the user guide book carefully before using this product
Skyworth LCD Video Wall Controller User Manual Please read the user guide book carefully before using this product 1 Contents 1. Features 2. Specifications 3. Control System Illustration 4. Operation 2
DeviceNet Bus Software Help for Programming an Allen Bradley Control System
FBP FieldBusPlug V7 DeviceNet Bus Software Help for Programming an Allen Bradley Control System DeviceNet Software Help for Programming an Allen Bradley Control System Contents Page General Purpose...
KNX Panasonic Air Conditioners
IntesisBox KNX Panasonic Air Conditioners Gateway for Panasonic ECOi and PACi system integration into KNX networks Up to 30 Outdoor units Up to 64 Indoor units PA-AC-KNX-64/128 EIA485 U1U2 line U1U2 line
Bright House Networks Home Security and Control Mobile Application
Bright House Networks Home Security and Control Mobile Application Quick Start Guide LIC# EF20001092 Home Security and Control Mobile App User Guide Table of Contents Installing the Mobile Application...
