Cabling solutions for networks Cables, modules, applications and data centers

Size: px
Start display at page:

Download "Cabling solutions for networks Cables, modules, applications and data centers"

Transcription

1 Passion for electricity Cabling solutions for networks Cables, modules, applications and data centers Intelligent system and switch components I/O components, routers and switch cabinet components in cooperation with

2 System overview Category 6A Cat.6A, Cat.6 A? There is some confusion on the market as to the designations and the specifications of the Cat.6 A standard, as two valid standards apply to it. The specifications of the TIA/EIA (American standard) are characterized by less strict values and do not distinguish between the cabling section and the component. Everything is referred to as a category (Cat.) here. On the other hand, the ISO/IEC (international standard) distinguishes between cabling sections (Class) and the component (Cat.), and the specifications are more demanding. In addition, the two standards differ in the spelling of Cat.6A (TIA/EIA) and Cat.6 A or Class E A (ISO/IEC). The performance of a Cat.6 A channel link according to EIA/TIA is not comparable with the performance of a Class E A channel link according to ISO/IEC! If you want to make sure as a user that you obtain optimum cabling according to Class E A, then you must use the components of the Cat.6 A specification according to ISO/IEC. Independent certification The connection system complies with the international Cat.6 A standard and has been tested and certified by an independent accredited test laboratory according to ISO/IEC Ed (FPDAM ), TIA/EIA-568-C.2 ( ) and IEC Ed.1 (12/2008). The requirements for Class E A are also complied with in the permanent and channel link according to the standard specified above. 2 Passion for electricity

3 Installation cables Category 6 A, Category 7, Category 7 A GC1500 pro22 Cat.7 A S/FTP 4P LSHF-FR AWG22 S/FTP Applicable standards: EN : ; ISO/IEC Ed.2.2: ; EN ; IEC and IEC Flame retardance: IEC ; IEC ; IEC and IEC GC1200 pro22 Cat.7 A S/FTP LSHF-FR AWG22 S/FTP Applicable standards: EN : ; ISO/IEC Ed.2.2: ; IEC and IEC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR AWG23 S/FTP Applicable standards: EN : ; ISO/IEC Ed.2.2: ; EN ; IEC and IEC GC1000 plus23 Cat.7 S/FTP LSHF AWG23 S/FTP Applicable standards: EN : ; ISO/IEC Ed.2.2: ; IEC and IEC GC600 F1 23 Cat.6 A U/FTP 4P LSHF AWG22 S/FTP Applicable standards: EN 50173; ISO/IEC and EIA/TIA 568A C6 A modul 180 and C6 A modul K 180 Modul cut-out Keystone cut-out C6Amodul 180 and C6Amodul K 180 Modular termination unit RJ45 Certified GHMT Cat.6 A re-embedded PVP Component testing for Cat.6 A to ISO/IEC Ed.2.2: , DIN EN : , TIA/EIA-568-C.2 ( ) and IEC Ed.1 (12/2008), certified to GHMT Compliance with class E A up to 500 MHz to ISO/IEC Ed.2.2: , class E A EN : Tested: component up to 600 MHz, link up to 800 MHz For 10 GBit Ethernet (IEEE 802.3an) Suitable for Power over Ethernet (PoE, PoE plus and UPoE) Easy to install connection of data lines AWG 26/1 to 22/1 (solid wire) and AWG 26/7 to 22/7 (stranded wire) to insulation displacement connectors (IDC) Intelligent cable management in stuffer cap - also suitable for heavily twisted cables Conductor assignment to T568A and T568B is directly printed on the stuffer cap Solid, one-piece and reusable module housing refined with zinc die-casting Mounting without special tools; strain relief directly snapped on to stuffer cap Mounting version: Modul cut-out, cable feed 180, 270 or 90 Keystone cut-out, cable fee 180, 270 or 90 Passion for electricity 3

4 Assembly scheme C6 A modul 180 and C6 A modul K Assignation des brins PIN No. T568A T568B 1 WH-GN WH-OG 2 GN OG 3 WH-OG WH-GN 4 4 BU BU 5 WH-BU WH-BU 6 OG GN 7 WH-BN WH-BN 8 BN BN Equipped and unequipped applications 19 Module frame 1RU aluminum/black unequipped REGplus IP20 C6 A modul 180 & C6 A modul 270 Modul IP44SG surface mounting housing unequipped Lockable flush-mounted IP44 outlet, with two keyswith lock with instantaneous locking action (identical locks and keys) Cover closes completely, even when patch cables are plugged in For two individual modules in Modul design (not suitable for OpDAT modules) Ball-throw proof according to DIN Can be operated with standard patch cables Clearly visible nomenclature panel Bottom section of housing can be turned 180, with cable feed possible from top and bottom With space to install the required spare cable lengths Gray Keystone wall outlet AP surface mounting unequipped Very compact 1-port surface-mounted termination unit for one individual Keystone module Module plug direction 90 downwards Strain relief with cable tie at the module Label window for identification labels (labels included in the delivery) Integrated dust protection shutter Cover parts in color similar to pure white RAL 9010, glossy surface Not suitable for 180 couplers (anti-bend sleeves for patch cables usually too long) Variants: 1 port, 2 ports 4 Passion for electricity

5 Equipped and unequipped applications Patch cable Cat. C6 A AWG26 Fully shielded Cat.6 A patch cable AWG 26/7 Two shielded RJ45 connectors; 1:1 assignment Class E A Link up to 500 MHz to ISO/IEC Ed.2.2: , DIN EN : Suitable for 10 GBit Ethernet (IEEE 802.3an) Molded snagless anti-bend sleeve -coated in cable color with integrated lock hook protection Halogen-free Colors may differ slightly due to different protection lots Keystone wall outlet for 6/12 port surface mounting Very compact 6/12-port surface-mounted termination unit for six/twelve individual Keystone modules Module plug direction 90 downwards Strain relief with cable tie at the module Cover parts in color similar to pure white RAL 9010, glossy surface With shielded modules suitable for 6 modules C6 A Module 270 Surface-mount or flush-mount termination unit with C6 A modul 270 Certified to GHMT Cat.6 A re-embedded PVP Component testing for Cat.6 A to ISO/IEC E.2.2: , DIN EN : , TIA/EIA-568-C.2 ( ) and IEC Ed.1 (12/2008), certified to GHMT Compliance with class E up to 500 MHz to ISO/IEC Ed.2.2: , DIN EN : Tested: component up to 600 MHz, link up to 800 MHz for 10 GBit Ethernet (IEEE 802.3an) Suitable for Power over Ethernet (PoE, PoE plus and UPoE) Connection of data lines AWG 26/1 to 22/1 (solid wire) and AWG 26/7 to 22/7 (stranded wire) to insulation displacement connectors (IDC) Module plug direction 45 downwards Strain relief snapped on to stuffer cap With label window for enclosed identification labels Label sheet 209 x 294 mm Integrated dust protection covers (also colored) Cover parts in pure white RAL 9010, structured surface with matt finish C6A RJ45 field plug pro 180 Cat.6A class EA RJ45 plug to be assembled in the field (fully shielded and multi-port capable) Compliance with class EA to ISO/IEC Ed.2.2: , DIN EN : GBit suitable according to IEEE 802.3an Straight (180 ) cable feed Easy assembly - connection without special tools Wire connection: stranded wire AWG 27/7 to 22/7, wire diameter from 0.46 to 0.76 mm Wire connection: solid wire AWG 26/1 to 22/1, wire diameter from 0.4 to 0.64 mm C6A RJ45 field plug pro 360 Cat.6A class EA RJ45 plug to be assembled in the field (fully shielded and multi-port capable) Compliance with class EA to ISO/IEC Ed.2.2: , DIN EN : GBit suitable according to IEEE 802.3an Variable (360 ) cable feed, freely selectable Easy assembly - connection without special tools wire connection: stranded wire AWG 27/7 to 22/7, wire diameter from 0.46 to 0.76 mm wire connection: solid wire AWG 26/1 to 22/1, wire diameter from 0.4 to 0.64 mm Passion for electricity 5

6 System overview Fiber optic Performance classes fiber optic cable Multimode Singlemode Standard IEC OM2 OM3 OM4 OS2 IEC A1a.1 ITU-T A1a A1a B6_a / B6_b G.657.A2/B2 Type of fiber 50/125 µm 50/125 µm 50/125 µm 9/125 µm Attentuation 850 nm 2,7 db/km 3,0 db/km 3,0 db/km 1300 nm 0,8 db/km 1,0 db/km 1,0 db/km 1310 nm 0,38 db/km 1550 nm 0,23 db/km Bandwidth (OFL) 850 nm 500 MHz.km 1500 MHz.km 3500 MHz.km 1300 nm 500 MHz.km 500 MHz.km 500 MHz.km Bandwidth EMB) 850 nm 2000 MHz.km 4700 MHz.km Fiber performace Singlemode OS2 Multimode OM1 Multimode OM2 Multimode OM3 Multimode OM4 10-gigabit transfer 2000 m 33 m 86 m 300 m 550 m OpDAT installation cables Universal cable (U-DQ(ZN)BH): Loose tube cable for interior and exterior with 4, 8, 12, 24 or 48 fibers (0.25 mm) Mini breakout cable (U-VQ(ZN)H): Cable for interior and exterior, with 4, 12 or 24 wires (0.9 mm) Breakout cable (I-V(ZN)HH): Interior cable with 2 cables All cable jackets LSHF (low-smoke, halogen-free) Fiber types: OM2, OM3, OM4, OS2. All fibers are bend insensitive. OpDAT patch cables & pigtails Assembly with all variations of plug types LC, SC and ST. Other plug types on request. Fiber types: OM2, OM3, OM4, OS2. Patch cable (Duplex, Figure 8) with outer diameter 2.0 x 4.2 mm. Cable jacket LSHF-FR (low-smoke, halogen-free, flame-retardant). Available in different lengths, maximum length 20 m Pigtails with compact wire 0.9 mm, length 2 m, primary and secondary coating (0.25 mm / 0.9 mm) same color. Available as individual pigtail or in a set of % optically inspected for insertion and return loss. Test reports are enclosed. OpDAT pre-assembled installation cables Assembly with all variations of plug types LC, SC and ST. Other plug types on request. Three cable versions: Universal cable: Loose tube cables for interior and exterior with up to 48 fibers (0.25 mm), Mini breakout cable: Cable for interior and exterior with 4, 12 or 24 wires (0.9 mm) Breakout cable: Interior cable with 2 cables (2.1 mm) Fiber types: OM2, OM3, OM4, OS2. All fibers are bend insensitive. Customized manufacture, maximum length 1000 m. 100% optically inspected for insertion and return loss. Test reports are enclosed. OpDAT patch panels Fiber optic patch panels for 19 inch technology, 1 rack unit (RU) Lightweight aluminum construction Fitted with pigtails and couplers (screwed) Service-friendly mounting through snap-on cover or removable drawer Splice trays with pigtails and crimp splice holders prepared ready-to-splic Pigtails cleaned and plugged into couplers Assignment according to color code to IEC Available with SC-Duplex, LC-Duplex and ST couplers. Other types on request. 6 Passion for electricity

7 Intelligent system composants Highly communicative and decentralized control Bus modules C Logline stands for intelligent system composants for a highly communicative and decentralized control in the application and products areas building automation, measurement and monotoring relays, interface modules, industrial relays and telecommunication. LON I/Os CAN-bus I/Os M-Bus I/Os Ethernet I/Os BACnet I/Os MOD-Bus I/Os MR-DIO4/2-IP LF-AI8 FRAS 4/21 MOXA EtherDevice Switch 8 Port Interface modules KRA-SRA-F10/21 RM3-2W 24 V DC ADU-C12 R274-4 changeover contacts (DPST) ADU-C12 Time, measurement and monotoring relays MR-DIO4/2-IP LF-AI8 Passion for electricity 7

8 Compact solutions for data centers The heart of every network is its data center. The type of processed data ranges from simple text documents up to complex design drawings, from production control systems up to building management plans. And the requirements in terms of performance and capacity rise exponentially. Networks soon reach their limits in the light of the extreme large data volumes that must be processed and archived today so that they must again and again be extended. And in those cases compact, inexpensive and quick solutions must be provided that use the available space in ideal fashion and reduce immobilization times to the absolute minimum. The compact solutions from METZ CONNECT in copper (Cat.6A) and FO are exactly tailored to the demands arising from data centers. The DataCenterCompactSolution (DCCS) excels not only by its high packing density, its low installation works and costs (pre-assembled RJ45 and FO plugs) but also by its Plug & Play design. This pre-assembled and measured system prevents installation errors. With this solution also jammed cable lines are a matter of the past. This optimizes the transparency and reduces the risk of heat accumulation. The use of DCCS installation cables leads also to a significant reduction of the thermal load. The following pages present all those numerous products and systems, which will help you to prepare also your data center for the next challenges. DCCS 6 x LC-D Link Prefabricated fiber optic link consisting of 2 subassembliesdc- CS2 with 6 LC-D couplers mounted to a 12 fiber mini breakout cable Port numbering of the DCCS2 19 subassembly frame remains in place when installing the FO subassemblies For 10 GBit Ethernet (IEEE 802.3an) The locking levers of patch cords connected to DCCS2 subassemblies show upwards and are easy to handle at any time Solid and refined assembly housing Cable diameter less than 6,5 mm Delivery with serial number and 12 attenuation measurements reports Mounting version: DCCS2 Available in prefabricated, customer specific lengths Maximum length: 500 m Configuration tool in Microsoft Excel available on request Variants: SM (OS2), SM (OS2 APC), MM (OM4), MM (OM3) DCCS2 fiber optic MPO link Pre-assembled fiber optic link consisting of one MPO plug on each side and a 24-fiber connection cable For up to 10 GBit Ethernet (IEEE 802.3an) 9 = 12 fibers E9/125 OS2 5 = 12 fibers 50/125 OM3 7 = 12 fibers 50/125 OM = 1.0 m 0015 = 1.5 m 0050 = 5.0 m 0100 = 10.0 m 0150 = 15.0 m 0200 = 20.0 m 0995 = 99.5 m 1000 = m 5000 = m Fiber type Length 130D2F X MP X XXXXX E Allocation A = Polarity, method A B = Polarity, method B C = Polarity, method C 8 Passion for electricity

9 Polarity, method A Module Key up to Key up Key up Key Down A-to-B Patch cord Position 1 Position 1 A-to-B Patch cord Key up to Key up Key up Key Down Position 1 Position 1 Module Polarity, method B Module Key up to Key up Key down to Key down A-to-B Patch cord Position 1 Position 1 A-to-B Patch cord Key down to Key down Key up to Key up Position 1 Position 1 Module Polarity, method C Key up to Key up Module Key up to Key down A-to-B Patch cord Position 1 Position 1 A-to-B Patch cord Key up to Key up Key up to Key down Position 1 Position 1 Module Passion for electricity 9

10 Industrial cabling IP protected connectors The Fit-for-All principles Benefit from maximum flexibility! This range of products does not only offer decisive advantages for your industrial applications but also for their planning, assembly and their daily use. All housings are designed to the protection degree IP67. Simply select your type of application and your desired material. You may choose between plastic and metal. Same color dot = combination possible. Plug inserts Plug housing Flange housing Flange inserts Industry IP67 V1 metal plug housing * Industry IP67 V1 metal bulkhead * Modul RJ45 Magnetics E-DAT Industry RJ45 plug insert * E-DAT Industry RJ45 coupler insert * Industry IP67 V1 plug housing * Industry IP67 V1 bulkhead * E-DAT Industry RJ45 field jack * E-DAT Industry RJ45 field plug insert * Industry IP67 V4 plug housing * Industry IP67 V4 bulkhead * OpDAT Industry SC-RJ/2SC adapter insert * OpDAT Industry 2SC plug insert * OpDAT Industry LC-D adapter insert * Industry IP67 V5 metal plug housing * Industry IP67 V5 metal bulkhead * OpDAT Industry 2LC plug insert * LC-D SFP Transceiver Industry IP67 V14 plug housing * Industry IP67 V14 bulkhead * E-DAT Industry USB A coupler insert * 10 Passion for electricity

11 Ethernet M12 Ethernet M12 round connectors The Ethernet M12 plug is an industrial plug of the round plug category; it has a metrical M12 thread 1. The METZ CONNECT Ethernet M12 plug series has been especially designed and compiled for data transmission systems in industrial environments. METZ CONNECT offers 2-pair twisted-pair connectors M12 with D-coding and 4-pair twisted-pair connectors M12 with X-coding. The 4-pole Ethernet M12 plug with D-coding offers a transmission ratio of 100 MBit/s. For higher data transmission ratios up to some Gigabits (e. g. 10 Gigabit), we offer 8-pole Ethernet M12 plugs with X-coding. The rugged Ethernet M12 plugs excel by their extremely strong mechanical and electrical resistance. In addition they are resistant against dirt and humidity once they are plugged in (IP67). This ensures safe contacts and a trouble-free data transmission. M12 field plug straight M-coded plug based on IEC PAS and suitable for field packaging 10 GBit suitable according to IEEE 802.3an Suitable for Power over Ethernet (PoE, PoE plus and UPoE) 8-wire M12 plug for AWG 22 to be assembled in the field Connection of AWG 26/7-22/7; AWG 24/1-22/1 possible Solid copper wire diameter from 0.4 to 0.64 mm Stranded copper wire diameter from 0.48 to 0.76 mm Conductor diameter up to 1.6 mm Cable jacket from 5.0 to 9.7 mm Consists of only 2 parts Easy assembly - connection without special tools Zinc die-cast housing for industrial use Passion for electricity 11

12 Telec Belgium Passion for electricity Rue des Rivageois 1A 4000 Liège Belgium Phone: +32 (0) Fax: +32 (0) Telec Luxembourg Passion for electricity Rue de Marbourg 19 box Marnach Luxembourg Phone: +352 (0) Fax: +352 (0) [email protected] Passion for electricity

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 8-poles Overview Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs

More information

C6 A modul and C6 A modul K. The new connection system for all applications of course with Cat.6 A

C6 A modul and C6 A modul K. The new connection system for all applications of course with Cat.6 A C6 A modul and C6 A modul K The new connection system for all applications of course with Cat.6 A Intelligent solution for structured cabling systems There is an enormous need for high data transfer rates

More information

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module R&Mfreenet Advanced R&Mfreenet Advanced Cat 6 A Connection Module The R&Mfreenet Cat 6 A unshielded connection modules, part of the Advanced cabling system, are ideal for voice, fast data transmissions

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs

More information

Simpler all over. Simpler all round. 500 MHz. 10 GB ether. fully shielded. Poe+ Cat.6 A. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug

Simpler all over. Simpler all round. 500 MHz. 10 GB ether. fully shielded. Poe+ Cat.6 A. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug Simpler all over. Simpler all round. No special tools required for field ASSEMBLY Cat.6 A 10 GB ether. 500 MHz fully shielded Poe+ Data Voice MFP8 Cat.6 A Field assembly RJ45 plug Less fuss. More flexibility.

More information

Accelerating Light. Copper Cabling Solutions. Category 6A

Accelerating Light. Copper Cabling Solutions. Category 6A Accelerating Light Copper Cabling Solutions Category 6A Category 6A Copper Cabling Solutions Fibernet designs and manufactures premium, high performance copper communication infrastructure and connectivity

More information

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS . HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or

More information

IP 20 B.1 8 IP 65 / IP 67 B.1 22. Cables B.1 96. Tools B.1 104 IP 20 B.2 8 IP 65 / IP 67 B.2 22. Cables B.2 90. Tools B.2 100 IP 20 B.

IP 20 B.1 8 IP 65 / IP 67 B.1 22. Cables B.1 96. Tools B.1 104 IP 20 B.2 8 IP 65 / IP 67 B.2 22. Cables B.2 90. Tools B.2 100 IP 20 B. Ethernet cabling Contents Page B Ethernet cabling Ethernet cabling overview B 2 Profil-specific Cabling 4-wires B.1 8 B.1 22 Cables B.1 96 Tools B.1 104 Structured Cabling 8-wires B.2 8 B.2 22 Cables B.2

More information

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned) 1 1 9.41 115 0 Patch cables are used 143 12 Fibre MTP Jumper, MTP (non-pinned) to Patch cables are used for non -permanent connections between patch panels, transmission equipment, etc. Pre -assembled

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on

More information

USB 3.0 Cables. Color. Black Black Black Black Black 3021003-03 3021009-06 3021015-10 3021021-16 3021027-16. Black Black Black Black Black

USB 3.0 Cables. Color. Black Black Black Black Black 3021003-03 3021009-06 3021015-10 3021021-16 3021027-16. Black Black Black Black Black USB.0 CableS USB.0 and backwards compatible for USB.0 and. Supports high speed, 480Mbps Twisted-pair construction reduces cross talk to ensure error free transfer USB A male to USB B male 00-0 007-0 0-09-

More information

SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS

SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS STRUCTURED CABLING SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS INTRODUCTION In recent years, communications have taken on a crucial role in development for businesses. Communications

More information

Configuration RJ-45 (IEC 60603-7-5) 6-7. Categories and NEW terms EN 50173-1, ISO/IEC 11801 10-11. De-embedded Re-embedded 14-15

Configuration RJ-45 (IEC 60603-7-5) 6-7. Categories and NEW terms EN 50173-1, ISO/IEC 11801 10-11. De-embedded Re-embedded 14-15 Index of contents Structure of standardization organization 3 General standards 4 Modular connectors vs. RJ-trade name 5 Configuration RJ-45 (IEC 60603-7-5) 6-7 Translation American Wire Gauge to metric

More information

The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.

The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification. 10 Cables The cables referred to below are provided with standard single- and multimode fibers. Other commercially available fibers can be provided on request. The bare fibers are colored in all cases

More information

The Quality Connection. Industrial IT cabling ISO/IEC 24702 / EN 50 173-3

The Quality Connection. Industrial IT cabling ISO/IEC 24702 / EN 50 173-3 The Quality Connection Industrial IT cabling ISO/IEC 24702 / EN 50 173-3 LEONI Kerpen & HARTING worldwide LEONI Kerpen and HARTING... For more than 85 years now, LEONI Kerpen as one of the leading companies

More information

HARTING mcon 1000 Introduction and features

HARTING mcon 1000 Introduction and features Introduction and features HARTING mcon 1000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features Supporting Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s)

More information

Structured Cabling, Earthing & Equipotential Bonding

Structured Cabling, Earthing & Equipotential Bonding White Paper Information and Communication Technology Structured Cabling, Earthing & Equipotential Bonding English Rev. 1.0.1 / 2012-06-01 1 Abstract All Dallmeier network products (PoE cameras, recorders,

More information

PURE : REliable planning of data center cabling

PURE : REliable planning of data center cabling PURE : REliable planning of data center cabling THE PURE EFFEct: TWICE AS MANY CONNEctionS AND 15 METERS MORE CHannEL LEngtH * PreCONNECT PURE is a milestone in the development of high-end IT cabling for

More information

Category 6 UTP - Cabling System

Category 6 UTP - Cabling System AMP NETCONNECT Category 6 UTP Cabling System...... real Category 6 Performance, both on Component as well as on System level! Owing to the extreme high performance of the AMP NETCONNECT Category 6 UTP

More information

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects.

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects. FC black process black LockPORT Security Patch Cables CAT5e, CAT6 and Fibre 5th black Secure network ports from unauthorized access and accidental disconnects. BLACK BOX» LockPORT cables stay locked in

More information

LANC Fibre Patch Panel Solution

LANC Fibre Patch Panel Solution features and benefits Modular front with interchangeable fibre optic adapter modules Quick mount feature (teardrop design) Port numbers printed above and below adapter modules High-density using LC connectivity

More information

Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4.

Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4. Category 6 Solutions Introduction... 4.2 Cable... 4.3 Patch Panels... 4.4 Modules... 4.6 Patch Cords... 4.12 Outlets... 4.16 Faceplates...4.18 4. 1 Search Category 6 Solutions Introduction ADC KRONE s

More information

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit

More information

How To Make A Fibre Cable For A Data Centre

How To Make A Fibre Cable For A Data Centre LANmark-OF Fibre Optic Solutions for Data Centres Complex Data Centres require fibre solutions CORE SWITCH ACCESS SWITCH SERVER SAN SWITCH LANmark-OF Slimflex Patch Cords LANmark-OF Single Mode LANmark-OF

More information

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair Presentation; Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair 5 th April 2010 Paul Mathews MInstSMM, CCNA, MIEEE Global Channel Manager Media Types Physical Layer Cabling;

More information

Optical Fibers Fiber Optic Cables Indoor/Outdoor

Optical Fibers Fiber Optic Cables Indoor/Outdoor presents Optical Fibers Fiber Optic Cables Indoor/Outdoor Content Optical fiber function, types optical effects applications production of optical fibre Cable - general types Indoor Indoor / outdoor Outdoor

More information

Plug & Play Universal Systems

Plug & Play Universal Systems Plug & Play Universal Systems A LANscape Pretium Plug & Play Universal Systems for Data Centers and Storage Area Networks (SANs) Corning Plug & Play universal systems create a fiber optic tip-to-tip solution

More information

E Series. E Series. Category 6 and 5e. Features

E Series. E Series. Category 6 and 5e. Features E Series Category 6 and 5e CommScope, world leader in copper and fiber connectivity, offers the E Series product line as the ideal solution to all your infrastructure needs for safe and reliable data transmission.

More information

MapIT G2 Infrastructure Management

MapIT G2 Infrastructure Management MapIT G2 Infrastructure Management Introducing MapIT G2, a complete upgrade of Siemon s popular MapIT intelligent infrastructure management (IIM) solution. MapIT G2 integrates a powerful combination of

More information

INTELLIGENT INFRASTRUCTURE MANAGEMENT

INTELLIGENT INFRASTRUCTURE MANAGEMENT F/ System F/ Assemblies, 9.0 W W W. S I E M O N. C O M SECTION CONTENTS System...............................9. IM Software........................... 9. Analyzers..............................9. System

More information

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). DIVISION 27 COMMUNICATIONS 27 00 00 COMMUNICATIONS A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). B. Comply with American National Standards Institute

More information

ETHERLINE Ethernet Cable, Connectors & Tools

ETHERLINE Ethernet Cable, Connectors & Tools Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary

More information

ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6 050R6800016 CABLE AND WIRING SERVICES (Column A) (Column B) (Column C) (Column D) (Column E) (Column F) (Column G) (B+C+D+E)*F= G Item Description PER 100' RUN PER 150' RUN PER 200' RUN PER 300' RUN QUANTITY

More information

HARTING econ 3000 Introduction and features

HARTING econ 3000 Introduction and features HARTING Introduction and features HARTING es, unmanaged, for installation in control cabinets General Description Features The Fast es of the product family HARTING are suitable for industrial applications

More information

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications. Issued 2005/06/01 Section 16743 Data System Page 1 of 7 PART 1 GENERAL 1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications..2 Data system equipment

More information

Discontinued. Volition. Fiber Optic Cable. 3Innovation

Discontinued. Volition. Fiber Optic Cable. 3Innovation Volition Fiber Optic Cable Tough enough to take it. Easy to handle. The Volition Network Solution from 3M includes horizontal and backbone cable with 62.5/125 µm and 50/125 µm multimode fiber, and 9/125

More information

HP ProCurve High-Speed Transceivers Installation Guide

HP ProCurve High-Speed Transceivers Installation Guide HP ProCurve High-Speed Transceivers Installation Guide Introduction The HP ProCurve High-Speed Transceivers can be installed into a number of HP ProCurve networking devices to provide 100 Mbps and 1000

More information

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8 Data Center Guide 1 Our Philosophy As a leader in the enterprise cable industry since our inception over three decades ago, we can help you implement the solution that will work best for your cabling infrastructure,

More information

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation Data Center Pre-terminated Patch Panel System Patch Panels Plug & Play Installation 10G + Gigabit Patch Cords Bundled + Labeled Cabling Systems Simplified Our Mission At Cablesys, our mission is to simplify

More information

Rutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions.

Rutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions. Rutenbeck Network Connection Box Cat. 5, shielded 1-gang, 1 x 8-pole Order No.: 0180 00 2-gang, 2 x 8-pole Order No.: 0178 00 1-gang, (especially for channel construction) Order No.: 0802 00 2-gang, (especially

More information

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide M7250P PoE Powered Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX Installation Guide September 2009 VERSITRON, Inc. 83 Albe Drive - Suite C Newark, DE 19702 www.versitron.com www.versitron.com

More information

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector

More information

Copper Pre-terminated Assemblies

Copper Pre-terminated Assemblies Copper Pre-terminated Assemblies Copper Pre-Terminated Trunk Assemblies Overview Copper Pre-Terminated trunk assemblies are the perfect solution for Enterprise / Premise & Data Centre applications where

More information

Pretium Connector Housings

Pretium Connector Housings Pretium Connector Housings A LANscape Pretium Solutions Product Applications Main cross connect, intermediate cross connects and telecommunications rooms Rack or equipment cabinet installations Data center

More information

Polymer Coated Fiber Cable (PCF)

Polymer Coated Fiber Cable (PCF) Polymer Coated Fiber Cable (PCF) Panduit has introduced a Polymer Coated Fiber (PCF) to their fiber cable offering available in 50µm and 62.5µm core diameters. Along with this cable having a stronger durability

More information

BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors

BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors C O M M E R C I A L N E T W O R K I N G C O P P E R 15.13 Distribution Connectors, Multiplying Connectors and Modular Jack Connectors A0393146 QCBIX1A4 Connector BIX Distribution Connector The BIX Distribution

More information

Fiber Optic Specifications

Fiber Optic Specifications Fiber Optic Specifications All Fiber Optic shall be Corning Altos Single Mode OS1 Outdoor Loose Tube Gel Free Cable Corning Fiber Products only will be accepted and no substitutions or alternates will

More information

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. [email protected] - 800-843-9859 - www.powermation.

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation. 14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator

More information

The 10G wiring system

The 10G wiring system Edition 03.2010 The 10G wiring system Contents Page ITplus wiring system 2 3 Installation cables 4 5 Distribution equipment 6 7 Connecting technology 8 Connecting boxes 9 10 Patch cables 11 12 Wiring system

More information

AMP CO Ultra System Catalog

AMP CO Ultra System Catalog Catalog Table of Contents AMP CO Ultra Panels... 1 AMP CO Ultra Outlets... 3 AMP CO Inserts... 7 AMP CO Tools...16 AMP CO Ultra Panels AMP CO Ultra 24 Port High Density Patch Panel 19 2 U Patch Panel for

More information

Innovative Connectivity Solution for Maximum Performance and Security

Innovative Connectivity Solution for Maximum Performance and Security Innovative Connectivity Solution for Maximum Performance and Security Financial Institutions Supports high performance backbone which enables transfer of real-time financial information through voice,

More information

Enterprise Networks EMEA. Core Products FOR DATA CENTRES

Enterprise Networks EMEA. Core Products FOR DATA CENTRES Enterprise Networks EMEA Core Products FOR DATA CENTRES EMEA Data Centre Core Products 1 Data Centres GET IT RIGHT, Right Now. Corning Cable Systems offers tens of thousands of fibre optic products for

More information

Panduit 28 AWG Patch Cords Installation Guideline

Panduit 28 AWG Patch Cords Installation Guideline Panduit 28 AWG Installation Guideline Introduction Panduit is a leading supplier of Structured Cabling Systems and Unified Physical Infrastructure. Panduit solutions enable the physical infrastructure

More information

AMP NETCONNECT. EMEA Product Catalog

AMP NETCONNECT. EMEA Product Catalog AMP NETCONNECT EMEA Product Catalog What s New! & System Selector What s New...2 System Selector... 4 Table of Contents AMP NETCONNECT Systems by Name 1. MRJ21 System... 9 2. Sigma-Link System...15 3.

More information

HARAX circular connector

HARAX circular connector Show navigation HARAX circular connector Technical characteristics Specifications IEC 60 352-4 IEC 60 9475-2 Approvals HARAX M8-S/M12-S Rated voltage Rated current Diameter of individual strands Conductor

More information

Cabling Standards Update 2014

Cabling Standards Update 2014 Cabling Standards Update 2014 Dimitris Filippou Technical Director, Ltd. IEEE Member, BICSI Country Chair, ELOT Technical Committee TC93 Member, CENELEC TC215 Delegate of Greek National Committee, CENELEC

More information

6000 Series Buccaneer

6000 Series Buccaneer Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available

More information

The AMP NETCONNECT Cabling System Products

The AMP NETCONNECT Cabling System Products The AMP NETCONNECT Cabling System Products About the AMP NETCONNECT Business Unit The AMP NETCONNECT business unit of Tyco Electronics develops, manufactures and supplies a comprehensive range of communications

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide 31007950 7/2009 ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide 7/2009 31007950.02 www.schneider-electric.com NOTICE Read these instructions carefully, and look at the equipment to become

More information

Security & Surveillance Cabling Systems

Security & Surveillance Cabling Systems Security & Surveillance Cabling Systems Security and Surveillance Cabling Systems The video security industry is growing and ever-changing, offering a wealth of opportunity for today s security professionals.

More information

Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer

Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer [email protected] Outline Data Center Market Drivers Data Center Trends Optical Fiber and Related Standards 40G & 100G

More information

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber Introduction Migration Strategy for 0G and 00G Ethernet over Multimode Fiber There is a need for increased network bandwidth to meet the global IP traffic demand, which is growing at a rate of 0% per year

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

Standard Buccaneer - Ethernet

Standard Buccaneer - Ethernet IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version

More information

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories 2015 PRODUCT CATALOG 2ND EDITION LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories A technically and commercially

More information

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. 1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking

More information

114-22008. 8-Position Cat5e (EMT) Modular Plug Connectors. Application Specification

114-22008. 8-Position Cat5e (EMT) Modular Plug Connectors. Application Specification Application Specification 114-22008 02/May/2008 Rev H 8-Position Cat5e (EMT) Modular Plug Connectors NOTE All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are

More information

Cable Assembly Solutions at the Speed of Light

Cable Assembly Solutions at the Speed of Light Cable Assembly Solutions at the Speed of Light Peggy Kovling ACI Founder Peggy Kovling credits her extensive knowledge of the cable business, along with her abilities in customer relationship management,

More information

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR

More information

Connector and Cable Specifications

Connector and Cable Specifications APPENDIXB This chapter describes the connector and cable specifications. Connector Specifications, page B-1l Cable and Adapter Specifications, page B-5 Connector Specifications 10/100/1000 Ports, page

More information

SECTION 16750 VOICE AND DATA COMMUNICATION CABLING

SECTION 16750 VOICE AND DATA COMMUNICATION CABLING SECTION 16750 VOICE AND DATA COMMUNICATION CABLING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Store drawing set and general provisions of the Contract, including General and Supplementary Conditions and

More information

The Quality Connection. LEONI Datacom Solutions Data Center

The Quality Connection. LEONI Datacom Solutions Data Center The Quality Connection LEONI Datacom Solutions Data Center Infrastructure & Datacom LEONI is a global supplier of cabling systems and services for applications in the automotive business and other industries.

More information

AMP NETCONNECT Data Center Cabling Solutions

AMP NETCONNECT Data Center Cabling Solutions AMP NETCONNECT Data Center Cabling Solutions Modern business and administrative environments require today more and more sophisticated IT services, what leads to an increasing demand for data provision

More information

PHOENIX OPTIX WIRING AND INTERCONNECT SOLUTIONS

PHOENIX OPTIX WIRING AND INTERCONNECT SOLUTIONS PHOENIX OPTIX WIRING AND INTERCONNECT SOLUTIONS Copper or Fiber...Data & Power Solutions Optimized for Low Loss Performance in Commercial and Military Environments PHOENIX OPTIX Wiring Solutions that Meet

More information

DEPARTMENTAL REGULATION

DEPARTMENTAL REGULATION U.S. DEPARTMENT OF AGRICULTURE WASHINGTON, D.C. 20250 DEPARTMENTAL REGULATION SUBJECT: Service Center Technology Modernization Project (SCTMP) Wiring/Cabling Specifications for Service Center Agencies

More information

HARTING mcon 3000 Introduction and features

HARTING mcon 3000 Introduction and features Introduction and features HARTING mcon 3000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features The fully managed es of the product family HARTING mcon

More information

FTE Cabling Best Practices Author: Todd Bill, RCDD/NTS

FTE Cabling Best Practices Author: Todd Bill, RCDD/NTS FTE Cabling Best Practices Author: Todd Bill, RCDD/NTS Document ID: WP-07-01-ENG Original Issue Date: May 2007 Version: 1.0 FTE Cabling Best Practices 1 Table of Contents Introduction and Applicable Standards...3

More information

Maintaining Proper Polarity for Modular Pre-terminated Fiber Systems. Rudolph A. Montgelas Fiber Optic Senior Product Manager Ortronics/Legrand

Maintaining Proper Polarity for Modular Pre-terminated Fiber Systems. Rudolph A. Montgelas Fiber Optic Senior Product Manager Ortronics/Legrand Maintaining Proper Polarity for Modular Pre-terminated Fiber Systems Rudolph A Montgelas Fiber Optic Senior Product Manager Ortronics/Legrand November, 006 Introduction: Optical communication systems provide

More information

Cable Installation Project

Cable Installation Project Cable Installation Project 1. Intent. It is the intent of the U.S. Court of Appeals to install Category 6 (CAT6) data cabling in the Robert F. Peckham Federal Building and United States Courthouse, 280

More information

FCS-FCT-FCP Housings and Connector Panels. InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF 28e OS1/OS2

FCS-FCT-FCP Housings and Connector Panels. InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF 28e OS1/OS2 Product Family: Product: Fibre: LANscape Hardware Solutions FCS-FCT-FCP Housings and Connector Panels InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF 28e OS1/OS2 Applications Corning Cable

More information

1st Edition Ethernet/Data Connectivity

1st Edition Ethernet/Data Connectivity 1st Edition Ethernet/Data Connectivity Distribution Frames Patch Panels Accessories Table of Contents Distribution Frame Introduction...1 Ethernet Distribution Frame...5 Glide Cable Manager...6 Patch

More information

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide 8-port 10/100Base-TX +2-port 100Base-FX Switch User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by

More information

Data Centre & Enterprise Solutions. RapidNet

Data Centre & Enterprise Solutions. RapidNet H E L L E R M A N N T Y T O N Data Centre & Enterprise Solutions RapidNet data centre & Enterprise solutions HellermannTyton is a leading global manufacturer of network cabling solutions which connect,

More information

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available with metal or plastic bodies, the range supports both data (USB and Ethernet),

More information

FullAXS CONNECTOR SEALING & CABLE ASSEMBLY

FullAXS CONNECTOR SEALING & CABLE ASSEMBLY FullAXS CONNECTOR SEALING & CABLE ASSEMBLY System Solution Guide Next Generation x-tta Solution Next generation WiMAX and Long Term Evolution (LTE) Fiber/Power/Signal To The Antenna (x-tta) connectivity

More information

Reliable, Consistent, Quality

Reliable, Consistent, Quality Reliable, Consistent, Quality 1-877-320-3143 www.fibertronics.com Reliable, Consistent, Quality Welcome To Fibertronics Inc. Reliability, consistency, and quality is what we put behind every Fiber optic

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

SMARTen 24 STP Patch Panels

SMARTen 24 STP Patch Panels Features Support 24 ports per 1U High performance, supportable bandwidth up to 500MHz supporting IEEE 802.3an 10Gbps application Conform to ANSI/TIA/EIA-568-B.2-10, ISO/IEC 11801 2.1 edition and CENELEC

More information

Cat. 6 A EL Incredibly fast Get more

Cat. 6 A EL Incredibly fast Get more Cat. 6 A EL Incredibly fast Get more Productive Intuitive installation Reliable Dependable connection Flexible Wide range of applications Productive. Intuitive installation. Just a few flicks of the wrist

More information

AMPTRAC TM CONNECTIVITY MANAGEMENT SYSTEM

AMPTRAC TM CONNECTIVITY MANAGEMENT SYSTEM AMP NETCONNECT TM AMPTRAC TM CONNECTIVITY MANAGEMENT SYSTEM The AMPTRAC Connectivity Management System turns cabling systems and their connected devices into intelligent networks by reducing costly and

More information

Industry solutions: Broad cast

Industry solutions: Broad cast Industry solutions: Broad cast BC 2 industry solutions: Broadcast Optical Cable Corporation s broad range of Fiber Optic Broadcast Cables are specifically designed for real-time transmission of high definition

More information

SECURE Fiber Optic Products

SECURE Fiber Optic Products SECURE Fiber Optic Products LC SECURE Fiber Optic Products (Pages 9 and 10) LC SECURE Connectors, Cable Assemblies and Adapters MPO SECURE Fiber Optic Products (Pages 11 and 12) MPO SECURE Cable Assemblies

More information

HARTING Selection Guide Han-Modular Connectors

HARTING Selection Guide Han-Modular Connectors HARTING Selection Guide Han-Modular Connectors Han-Modular Connectors Description of the Han-Modular system The Han-Modular series is designed for combining different transmission media in one connector.

More information

M8 / M12 CONNECTOR SYSTEM

M8 / M12 CONNECTOR SYSTEM M8 / M12 CONNECTOR SYSTEM EVERY CONNECTION COUNTS TE CONNECTIVITY S M8 / M12 Connector System for machine industrial automation and control applications provides a solution that safely and reliably ensures

More information

Upgrading Path to High Speed Fiber Optic Networks

Upgrading Path to High Speed Fiber Optic Networks SYSTIMAX Solutions Upgrading Path to High Speed Fiber Optic Networks White Paper April, 2008 www.commscope.com Contents Connectivity Method A 4 Upgrading Method A to Parallel Optics 4 Connectivity Method

More information

hot products guide people. passion. expertise. gocsc.com

hot products guide people. passion. expertise. gocsc.com hot products guide gocsc.com Hardware & Adapter Panels who is CSC? Founded in 1972, Communications Supply Corporation (CSC), a subsidiary of WESCO International, Inc. (NYSE: WCC) distributes a full range

More information

Network Design. Yiannos Mylonas

Network Design. Yiannos Mylonas Network Design Yiannos Mylonas Physical Topologies There are two parts to the topology definition: the physical topology, which is the actual layout of the wire (media), and the logical topology, which

More information