1 SI unit for EtherCAT PRODUCT NAME EX260 Series MODEL/ Series
2 Contents Safety Instructions 2 How to Order 7 Summary of Product elements 8 Installation and Cabling 9 General instructions on installation 9 Connecting cables 10 LED indication and Settings 13 Troubleshooting and Maintenance 19 Specifications 23 Table of Specifications 23 Dimensions 25 Accessories 26-1-
3 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger". They are all important notes for safety and must be followed in addition to International standards (ISO/IEC), Japan Industrial Standards (JIS) *1) and other safety regulations *2). *1) ISO 4414: Pneumatic fluid power - - General rules relating to systems. ISO 4413: Hydraulic fluid power - - General rules relating to systems. IEC : Safety of machinery - -Electrical equipment of machines. (Part 1: General requirements) ISO : Manipulating industrial robots -Safety. JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B : Safety of machinery - Electrical equipment of machines. (Part 1: General requirements) JIS B : Manipulating industrial robots - Safety. etc. *2) Labor Safety and Sanitation Law, etc. Caution : Warning : Danger : CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications. Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment. 2. Only personnel with appropriate training should operate machinery and equipment. The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced. 3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully. 3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction. 4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions. 1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight. 2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog. 3. An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. -2-
4 Caution 1. The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch. Limited warranty and Disclaimer/Compliance Requirements The product used is subject to the following "Limited warranty and Disclaimer" and "Compliance Requirements". Read and accept them before using the product. Limited warranty and Disclaimer 1. The warranty period of the product is 1 year in service or 1.5 years after the product is delivered. *3) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch. 2. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product. 3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products. *3) Vacuum pads are excluded from this 1 year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty. Compliance Requirements When the product is exported, strictly follow the laws required by the Ministry of Economy, Trade and Industry (Foreign Exchange and Foreign Trade Control Law). Operator This operation manual has been written for those who have knowledge of machinery and apparatus that use pneumatic equipment and have full knowledge of assembly, operation and maintenance of such equipment. Please read this operation manual carefully and understand it before assembling, operating or providing maintenance to the product. -3-
5 Precautions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system. Check the product regularly for proper operation. Otherwise malfunction can result, causing an accident. The following instructions must be followed during maintenance: Turn off the power supply. Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance. Otherwise an injury can result. Caution After maintenance is complete, perform appropriate functional inspections. Stop operation if the equipment does not function properly. Safety cannot be assured in the case of unexpected malfunction. Provide grounding to assure the safety and noise resistance of the Serial System. Individual grounding should be provided close to the product with a short cable. -4-
6 NOTE Follow the instructions given below when designing, selecting and handling the product. The instructions on design and selection (installation, wiring, environment, adjustment, operation, maintenance, etc.) described below must also be followed. Product specifications The direct current power supply to combine should be UL1310 Class 2 power supply when conformity to UL is necessary. The SI unit is a approved product only if they have a mark on the body. Use the specified voltage. Otherwise failure or malfunction can result. Reserve a space for maintenance. Allow sufficient space for maintenance when designing the system. Do not remove any nameplates or labels. This can lead to incorrect maintenance, or misreading of the operation manual, which could cause damage or malfunction to the product. It may also result in non-conformity to safety standards. Product handling Installation Do not drop, hit or apply excessive shock to the fieldbus system. Otherwise damage to the product can result, causing malfunction. Tighten to the specified tightening torque. If the tightening torque is exceeded the mounting screws may be broken. IP67 protection cannot be guaranteed if the screws are not tightened to the specified torque. Never mount a product in a location that will be used as a foothold. The product may be damaged if excessive force is applied by stepping or climbing onto it. Wiring Avoid repeatedly bending or stretching the cables, or placing heavy load on them. Repetitive bending stress or tensile stress can cause breakage of the cable. Wire correctly. Incorrect wiring can break the product. Do not perform wiring while the power is on. Otherwise damage to the fieldbus system and/or I/O device can result, causing malfunction. Do not route wires and cables together with power or high voltage cables. Otherwise the fieldbus system and/or I/O device can malfunction due to interference of noise and surge voltage from power and high voltage cables to the signal line. Route the wires (piping) of the fieldbus system and/or I/O device separately from power or high voltage cables. Confirm proper insulation of wiring. Poor insulation (interference from another circuit, poor insulation between terminals, etc.) can lead to excess voltage or current being applied to the product, causing damage. Take appropriate measures against noise, such as using a noise filter, when the fieldbus system is incorporated into equipment. Otherwise noise can cause malfunction. Separate the power line for output devices from the power line for control. Otherwise noise or induced surge voltage can cause malfunction. -5-
7 Environment Select the proper type of protection according to the environment of operation. IP67 protection is achieved when the following conditions are met. (1) The units are connected properly with fieldbus cable with M12 connector and power cable with M12 (M8) connector. (2) Suitable mounting of each unit and manifold valve. If using in an environment that is exposed to water splashes, please take measures such as using a cover. If the product is to be used in an environment containing oils or chemicals such as coolant or cleaning solvent, even for a short time, it may be adversely affected (damage, malfunction etc.). Do not use the product in an environment where corrosive gases or fluids could be splashed. Otherwise damage to the product and malfunction can result. Do not use in an area where surges are generated. If there is equipment which generates a large amount of surge (solenoid type lifter, high frequency induction furnace, motor, etc.) close to the fieldbus system, this may cause deterioration or breakage of the internal circuit of the fieldbus system. Avoid sources of surge generation and crossed lines. When a surge-generating load such as a relay or solenoid is driven directly, use an fieldbus system with a built-in surge absorbing element. Direct drive of a load generating surge voltage can damage the fieldbus system. The product is CE marked, but not immune to lightning strikes. Take measures against lightning strikes in the system. Prevent foreign matter such as remnant of wires from entering the fieldbus system to avoid failure and malfunction. Mount the product in a place that is not exposed to vibration or impact. Otherwise failure or malfunction can result. Do not use the product in an environment that is exposed to temperature cycle. Heat cycles other than ordinary changes in temperature can adversely affect the inside of the product. Do not expose the product to direct sunlight. If using in a location directly exposed to sunlight, shade the product from the sunlight. Otherwise failure or malfunction can result. Keep within the specified ambient temperature range. Otherwise malfunction can result. Do not operate close to a heat source, or in a location exposed to radiant heat. Otherwise malfunction can result. Adjustment and Operation Perform settings suitable for the operating conditions. Incorrect setting can cause operation failure. Please refer to the PLC manufacturer's manual etc. for details of programming and addresses. For the PLC protocol and programming refer to the relevant manufacturer's documentation. Maintenance Turn off the power supply, stop the supplied air, exhaust the residual pressure and verify the release of air before performing maintenance. There is a risk of unexpected malfunction. Perform regular maintenance and inspections. There is a risk of unexpected malfunction. After maintenance is complete, perform appropriate functional inspections. Stop operation if the equipment does not function properly. Otherwise safety is not assured due to an unexpected malfunction or incorrect operation. Do not use solvents such as benzene, thinner etc. to clean the each unit. They could damage the surface of the body and erase the markings on the body. Use a soft cloth to remove stains. For heavy stains, use a cloth soaked with diluted neutral detergent and fully squeezed, then wipe up the stains again with a dry cloth. -6-
8 How to Order EX260-SEC 1 Connector type, output specification 1 M12 connector, 32 outputs, PNP (negative common) 2 M12 connector, 32 outputs, NPN (positive common) 3 M12 connector, 16 outputs, PNP (negative common) 4 M12 connector, 16 outputs, NPN (positive common) Fieldbus EC EtherCAT -7-
9 Summary of Product elements <EX260-SEC1/-SEC2/-SEC3/-SEC4> No. Element Description 1 2 Fieldbus interface connector (BUS OUT) Fieldbus interface connector (BUS IN) EtherCAT connection (M12 4-pin socket, D-coded) * 1 EtherCAT connection (M12 4-pin socket, D-coded) * 1 3 Power supply connector Power supply with load voltage for valves and operating voltage for SI unit * 1 (M12 5-pin plug, A-coded) 4 Ground terminal Functional earth (M3 screw) 5 Output connector Output signal interface for valve manifold 6 LED Bus status specific and SI unit specific LEDs * 2 7 Mounting hole Mounting hole for connection to the valve manifold Accessories Hexagon socket head cap screw Seal cap *1: Refer to page 10 for connecting cables. *2: Refer to page for the LED indication and settings. 2pcs. M3x30 screw for connection to the valve manifold 1pc. seal cap for unused fieldbus interface connector (BUS OUT) -8-
10 Installation and Cabling General instructions on installation Connect valve manifold to the SI unit. Dimensions for installation n: number of valve stations n The above table shows dimensions as an example for the SY5000 series valve manifold. Connectable valve manifolds are the same as for EX250 series SI unit. Refer to the EX250 series valve manifold section in the valve catalogue for valve manifold dimensions. (mm) -9-
11 Connecting cables Select the appropriate cables to mate with the connectors mounted on the SI unit. Fieldbus interface connector layout BUS OUT: M12 4-pin socket D-coded No. Designation Description 1 TD+ Transmit Data + 2 RD+ Receive Data + 3 TD- Transmit Data - 4 RD- Receive Data - BUS IN: M12 4-pin socket D-coded No. Designation Description 1 TD+ Transmit Data + 2 RD+ Receive Data + 3 TD- Transmit Data - 4 RD- Receive Data - Connect the BUS IN connector to the upstream device (PC, PLC etc.) and connect the BUS OUT connector to the downstream device. Note Be sure to fit a seal cap on any unused connectors. Proper use of the seal cap enables the enclosure to achieve IP67 specification. *1: Refer to page 26 for the seal cap. -10-
12 Power supply connector layout PWR: M12 5-pin Plug A-coded No. Designation Description 1 SV24 V +24 V for solenoid valve 2 SV0 V 0 V for solenoid valve 3 SI24 V +24 V for SI unit operation 4 SI0 V 0 V for SI unit operation 5 - Unused Power-supply line for solenoid valve and power-supply line for SI unit operation are isolated. Be sure to supply power, respectively. Either single-source power or two different power supplies can be used. Note) Pay attention not to exceed the tolerance range of power supply voltage. -11-
13 Ground terminal Connect the ground terminal to ground. Resistance to ground should be 100 ohms or less. -12-
14 LED indication and Settings LED indication LED LED Status Description RUN L/A IN L/A OUT PWR PWR(V) OFF Green Blinking *1 Green single flash *2 Green flickering *3 Green ON OFF Green ON Green flickering *3 OFF Green ON Green flickering *3 Green ON OFF Green ON OFF INIT PRE-OPERATIONAL SAFE-OPERATIONAL BOOTSTRAP OPERATIONAL BUS IN side: No Link, No Activity BUS IN side: Link, No Activity BUS IN side: Link, Activity BUS OUT side:no Link, No Activity BUS OUT side: Link, No Activity BUS OUT side: Link, Activity SI unit operating voltage is supplied SI unit operating voltage is not supplied Load voltage for the valve is supplied Load voltage for the valve is not supplied or outside tolerance range (19 V or less) *1: Blinking pattern *2: Single flash pattern *3: Flickering pattern -13-
15 Configuration Auto-increment addressing can be used address each slave device according to its physical position in the communication ring, and does not require local address setting. To configure the EX260 SI unit with the EtherCAT master, an XML Device Description File is required. The technical document giving detailed configuration information and the XML file can be found on the SMC website (URL Setting using System Manager 1. Copy the XML file * 1 for this unit to the following folder: C: TwinCAT lo EtherCAT (this path is valid only when the default setting is kept.) Start up the TwinCAT System Manager after copying. *1: The XML file for this product can be found on the SMC website (URL 2. Network setting 2-1. Off-line manual configuration method Right click the [I/O Devices] file, and then select [Append Device] Select the [EtherCAT] and [EtherCAT Adapter (Direct Mode)] files and click the OK button. -14-
16 Right click the [EtherCAT] file added to [I/O Devices], and select [Append Box] After clicking the [SMC Corporation] and [EX260 Series SI Unit] files in sequence, select the unit to be connected, and click the OK button. *: If EX260 Series SI unit is not found in the list, confirm whether the XML file of this unit is in the [ TwinCAT Io EtherCAT] folder, and start up [TwinCAT( System Manager] again If additional units are to be connected on the network, repeat steps and Apply the power supply to each unit after connecting the unit set above. Then, click [Reload I/O Devices] to make it on-line. -15-
17 2-2. On-line Auto Configuration Connect the unit to the network and apply the power. Then right click the [I/O Devices] file and select [Scan Devices] When the comment Scan for boxes appears, click the [YES(Y)] button. Once the scan is completed correctly, the products that are connected to the network are displayed as shown below. -16-
18 Output number assignment Output data Output layout of the 32 outputs type (Example of EX260-SEC1) Output layout of the 16 outputs type (Example of EX260-SEC3) Byte unit Byte unit Bit unit Bit unit -17-
19 *: The output number refers to the solenoid position on the manifold and starts at zero. *: Standard wiring on the manifold is for double-solenoid valves and output number starts A side and B side in that order as shown in the figure a. If you mount a single-solenoid valve on the standard wiring manifold, output number for B side valve is skipped. *: Custom wiring for mixed mounting single-solenoid valves and double-solenoid-valves can be specified with a Wiring Specification Sheet. Example wiring is shown in the figure b. *: Bit status 0 and 1 on a data corresponds solenoid valve status ON and OFF 0: OFF, 1: ON, and output number starts at zero from LSB (least significant bit). -18-
20 Troubleshooting and Maintenance Troubleshooting chart When any malfunction is observed, it is recommended to perform the following troubleshooting. Yes SI unit malfunction SI unit PWR_LED OFF Refer to fault No.1 No SI unit PWR (V)_LED OFF Refer to fault No.2 SI unit L/A IN_LED OFF Refer to fault No.3 SI unit L/A IN_LED stay Green Refer to fault No.4 SI unit RUN_LED OFF Refer to fault No.5 Group of valves not working Refer to fault No.6 All valves and valve LEDs are not operating Refer to fault No.7 Valves do not work but valve LEDs are operating Refer to fault No.8-19-
21 Troubleshooting table Fault No.1 Fault Probable cause Recommended error handling Recommended action SI unit PWR_LED OFF Fault No.2 Defective power cable wiring for SI unit operation SI unit operating voltage is not supplied Check the condition of the power cable wiring to the SI unit. Check the condition of the supply voltage to the SI unit. Re-tighten the power cable. (Replace the cable if it is broken) Correct the power cable wiring layout. Supply 24 VDC +/-10% to the SI unit. Fault Probable cause Recommended error handling Recommended action SI unit PWR(V)_LED OFF Defective power cable wiring for the solenoid valve Load voltage for the valve is not supplied Check the condition of the power cable wiring for the valve. Check the condition of the supply voltage for the valve. Re-tighten the power cable. (Replace the cable if it is broken) Correct the power cable wiring layout. Supply 24 VDC +10%/-5% to the valve. Fault No.3 Fault Probable cause Recommended error handling Recommended action SI unit L/A IN_LED OFF Fault No.4 The connection to the upper side device has failed Check the condition of the upstream device. Check the condition of L/A IN side bus cable wiring, and that there is no broken bus cable. Check that there is no noise source or high voltage line around the bus cables. Check the connection of the ground terminal. Supply voltage to the upstream device. Re-tighten the bus cable. (Replace the cable if it is broken) Keep noise sources away from the bus cable. Connect the ground terminal to ground. Fault Probable cause Recommended error handling Recommended action SI unit L/A IN_LED Stay Green No communication with EtherCAT master Check the condition of the EtherCAT master. Check the condition of the upstream device. (Check that there are no L/A LED s indicating OFF on any upstream devices) Check that there is no noise source or high voltage line around the bus cables. Set the EtherCAT master to RUN state. Supply voltage to the upstream device. Re-tighten the bus cable. (Replace the cable if it is broken) Keep noise sources away from the bus cable. -20-
22 Fault No.5 Fault Probable cause Recommended error handling Recommended action SI unit RUN_LED off SI unit is in INIT state Check that the EtherCAT master configuration setup for the SI unit matches the actual set up of the SI unit. Configure the SI unit by the EtherCAT master using the valid XML file. Match the SI unit configuration with the actual SI unit type. Fault No.6 Fault Probable cause Recommended error handling Recommended action Group of valves not working Too many valves Check if solenoid count does not exceed the allowable number. This depends on the SI unit model and valve series. Allowable solenoid number by valve series: SY/SV series: 32 points VQC/S0700 series: 24 points Keep the number of mounted solenoid valves within specification. Fault No.7 Fault Probable cause Recommended error handling Recommended action All valves and valve LEDs are not operating Poor connection between SI unit and valve manifold Mismatch polarity between solenoid valve and SI unit output Check if there are any loose screws making the connection between the SI unit and the valve manifold Check if the solenoid valve common specification matches the output polarity of the SI unit. Tighten the screws with the specified tightening torque (i.e. 0.6 Nm) and make sure there is no gap between the SI unit and the valve manifold. Match polarity between solenoid valve and SI unit output. Defective solenoid valve Follow the troubleshooting for the solenoid valve. Same as left. Fault No.8 Fault Probable cause Recommended error handling Recommended action Valves do not work but valve LEDs are operating Mismatch polarity between solenoid valve and SI unit output Check if the solenoid valve common specification matches the output polarity of the SI unit. Match polarity between solenoid valve and SI unit output. -21-
23 Maintenance Replacement of the SI unit Remove the M3 hexagon screws from the SI unit and release the SI unit from the valve manifold. Replace the SI unit. Tighten the screws with the specified tightening torque. (0.6 Nm) Precautions for maintenance (1) Be sure to switch off the power. (2) Check there is no foreign matter inside the SI unit. (3) Check there is no damage and no foreign matter on the gasket. (4) Be sure to tighten the screws with the specified torque If the SI unit is not assembled properly, inside PCBs may be damaged or liquid and/or dust may enter into the unit. Assembly and disassembly of the SI unit -22-
24 Specifications Table of Specifications General specifications Item Ambient temperature Ambient humidity Ambient temperature for storage Vibration resistance Impact resistance Withstand voltage Insulation resistance Operating atmosphere -10 to +50 o C 35 to 85%RH (No condensate) -20 to +60 o C Specifications 10 to 57 Hz 0.3mm (Constant amplitude) 57 to 150 Hz 50 m/s 2 (Constant acceleration) Peak value 150 m/s 2 applied for 11ms three times each in X, Y and Z directions. 500 VAC applied for 1 minute 500 VDC, 10 MΩ or more No corrosive gas Pollution degree Pollution degree 2 Weight 200 g or less Electrical specifications Current consumption in power supply voltage range Item Current consumption of controller power supply Solenoid valve power supply VDC 0.1 A max. Output EX260-SEC1/-SEC3 PNP (negative common) type EX260-SEC2/-SEC4 NPN (positive common) Specifications VDC 2.0 A or less, according to the solenoid valve station specification Solenoid valve connecting specification Output condition at the time of communication error Connected load Insulation type Residual voltage Output clear Solenoid valve with light and surge voltage suppressor of 24 VDC and 1.5 W or less (manufactured by SMC) Photo coupler insulation type 0.4 VDC or less -23-
25 Network communication specifications Protocol Item EtherCAT Specifications EtherCAT mode Direct Mode (No MAC address) *: Does not support Open Mode. Transmission speed 100 Mbps Transmission medium Standard Ethernet cable (CAT5) (100BASE TX) Number of nodes connected (Up to 65,535 nodes.) Network topology Daisy chain Maximum segment length Up to 100 m (328 ft) Address setting Manual setting is not required, automatically set Number of outputs EX260-SEC1/-SEC2 32 outputs EX260-SEC3/-SEC4 16 outputs Vendor ID hex (276) EX260-SEC hex ( ) Product code EX260-SEC hex ( ) EX260-SEC hex ( ) EX260-SEC hex ( ) Connectable valve series Valve Series SY series VQC series SV series S0700 series SY3000 SY5000 VQC1000 VQC2000 VQC4000 SV1000, SV2000, SV3000 (10 type tie-rod base) S0700 * The valve manifolds that can be connected are the same as those connectable to EX250 series. -24-
26 Dimensions -25-
27 Accessories Connector cable SI unit connector Fieldbus interface connector (BUS OUT) Fieldbus interface connector (BUS IN) Power supply connector Compatible connector Description Part number Specifications Manufacturer Cable with communication connector Cable with communication connector Cable with power supply connector EX9-AC020EN -PSRJ EX9-AC020EN -PSRJ EX500-AP010-S EX500-AP050-S EX500-AP010-A EX500-AP050-A Connector: M12 straight at one end and RJ45 at the other end Cable: 2m Connector: M12 straight at one end and RJ45 at the other end Cable: 2m Connector: M12 straight Cable: 1m Connector: M12 straight Cable: 5m Connector: M12 angle Cable: 1m Connector: M12 angle Cable: 5m SMC Seal cap (10 pcs.) The seal cap can be used to protect the opening M12 size connector socket, i.e. M12 BUS OUT connector on the SI unit. When M12 BUS OUT connector is not used, the seal cap can keep the SI unit under IP67 rated protection. (One seal cap will be attached to the SI unit when shipped from factory.) Description Part No. Specification Seal cap EX9-AWTS For M12 connector socket: 10pcs. -26-
28 Revision history Revision A: Revise some wording Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. EtherCAT is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. TwinCAT is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany SMC Corporation All Rights Reserved
E/P Regulator (DeviceNet TM type) ITV1000/2000/3000/2090-DE* Series
Doc. No. ITV2-OM00095-B P R O D U C T N A M E E/P Regulator (DeviceNet TM type) MODEL/ Series/ Product Number ITV1000/2000/3000/2090-DE* Series Install and operate the product only after reading the Operation
No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1
No. : EX##-OMF0004 OPERATION MANUAL EX12#-SMB1 Contents 1. Safety instructions ------------------------------------------------------ P3 2. Notes ------------------------------------------------------
EX##-OMN0013. SI unit for DeviceNet TM PRODUCT NAME. EX260 Seires MODEL/ Series
EX##-OMN0013 SI unit for DeviceNet TM PRODUCT NAME EX260 Seires MODEL/ Series Contents Safety Instructions 2 Summary of Product element 7 Names and Functions of Individual Parts 8 Mounting and Installation
CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual
Instruction Manual OPC-LM1-IL Option Card for Encoder of Line Driver Output CAUTION Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual
CQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual
Doc.No. NDP 192U-02 Electric Pump Controller CE-124P Instruction Manual 1. Parts Name and Function 1) POWER LED Indicate that CE-124P is powered up. 2) START/STOP KEY (SELECTOR KEY) Used to start and stop
User s Manual AURORA 1.2K/2.2K
User s Manual AURORA 1.2K/2.2K Uninterruptible Power System Safety CAUTION This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable
NX safety stand-alone
NX-S@ NX safety stand-alone stand-alone into machine automation Expandable safety system up to 32 safety connections or 63 standard connections controller flexible system lets your freely mix safety I/O
EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.
Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the
Installation and safety instructions for AC/DC built-in devices
The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
No.EX##-OMJ1003. SI Unit Lightbus compatible PRODUCT NAME. EX250-SLB1-DE MODE / Series
No.EX##-OMJ1003 SI Unit Lightbus compatible PRODUCT NAME EX250-SLB1-DE MODE / Series Table of Contents Safety Instructions 2 Names and functions of individual parts 7 LED Display 8 Glossary 9 Wiring 10
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual
Instruction Manual Option Card for Frequency Divider Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual and understand the description
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
How To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018
USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and
Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors
European Refrigeration Controls Catalogue Catalogue Section 4 Product Bulletin P215PR/RM Issue 01/03/2013 Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
Adjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
LEC-T1 Series. Teaching Box for Electric actuator. Applicable models : For Series LEC 6 PRODUCT NAME. MODEL / Series/Product Number
Doc. no. LEC-OM00504 PRODUCT NAME Teaching Box for Electric actuator MODEL / Series/Product Number LEC-T1 Series Applicable models : For Series LEC 6 Contents Safety Instructions... 5 Changes by teaching
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
PBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
aseries A13B Mini Bullet Camera User Manual
aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView
Smart DeviceNet Remote I/O Terminals
Smart DeviceNet Remote I/O Terminals ather and Use Information for Effective Preventive Maintenance et more useful data for preventive maintenance when you build cost-effective parallel information systems
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
Instructions for Safe Use
Instructions for Safe Use (Certification N:o VTT 08 ATEX 029) Thank you for choosing Slam Trans portable transformer for your job site. Purpose of this manual is to provide you all the necessary safety
alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS
alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS Safety precautions Safety precautions The DSL modem alpha DSL WTM HS complies with the European norm EN60950 safety of information technology
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.
User manual Rev 1.3 Contents
User manual Rev 1.3 Contents 1. Introduction...4 2. System specifications...5 2.1.. General overview...5 2.2. Maximum capacity...6 2.3. Electrical specifications...6 2.4. Mechanical specifications...6
5-port 10/100Base-TX Industrial Switch (314500) User s Guide
5-port 10/100Base-TX Industrial Switch (314500) User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by
Ordering Information. Cylindrical Proximity Sensor E2E/E2E2
Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened
User Manual. Video Doorphone CDV-1020AQ
User Manual Video Doorphone CDV-1020AQ 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int l Business Dept. Tel. : +82-31-7393-540~550 Fax. : +82-31-745-2133 Web site : www.commax.com
Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!
Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
www.iconnectivity.com
www.iconnectivity.com USER GUIDE WARRANTY INFORMATION iconnectivity warrants to the original purchaser that this unit is free of defects in materials and workmanship under normal use and maintenance for
Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection
MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)
Installation and Maintenance Manual IM 852 Group: Controls Part Number: IM 852 Date: June 2007 Supercedes: New MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)
Doc. no.lec-om03901a. PRODUCT NAME Programless controller Step motor (servo 24 VDC ) MODEL/ Series LECP1 Series
Doc. no.lec-om03901a PRODUCT NAME Programless controller Step motor (servo 24 VDC ) MODEL/ Series LECP1 Series Contents 2. Outlines of Product... 5 2.1 Features... 5 2.2 How to Order... 6 2.3 Structure
DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual
DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages
8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide
8-port 10/100Base-TX +2-port 100Base-FX Switch User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by
PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: WWW.BRITEQ-LIGHTING.COM TABLE OF CONTENTS
STGE COO 48 Preliminary User Guide Official version will follow soon on: WWW.BITEQ-IGHTIG.COM TBE OF COTETS 1. Safety Instruction 2. Technical Specification 3. How To Set The Unit 4. How To Control The
CMC-DN01 DeviceNet Slave Communication Card Operation Manual
CMC-DN01 DeviceNet Slave Communication Card Operation Manual 2011-12-26-A Warning This operation manual provides introduction on the functions, specifications, installation, basic operation and settings
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
3 Port Solenoid Valve
Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large
COLOR VIDEO DOOR PHONE CDV-71BE/D
COLOR VIDEO DOOR PHONE CDV-71BE/D 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int l Business Dept. : Tel.; +82-31-7393-540~550 Fax.; +82-31-745-2133 Web site : www.commax.com Printed
NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing
NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing Introduction: NS-205-IP67 Ethernet Switches are designed for use in industrial waterproof/harsh environments. The rugged packaging
VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control
VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)
Leak Detection System
Instructions - Parts List Leak Detection System 311200A For detecting leaks in your diaphragm pump system. Not for use in explosive atmospheres. Part No. 234576 120 psi (0.8 MPa, 8 bar) Maximum Air Input
Addendum to the Operating Instructions
Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions MOVIMOT with AS-Interface and AC Motor DT/DV Unit Replacement MOVIMOT MM..C -> MM..D with MLK3A
LCD Readout Digital Pressure Switch
LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL
PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
Liquid Leakage Sensor Amplifier
9 Liquid Leakage Sensor Amplifier Space-saving Sensor Amplifier reliably detects a wide variety of liquids ranging from water to chemical liquids with low conductivity 1 Detects leakage of liquid such
Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20
Documentation for KL2602 and KL2622 Two-channel Relay Output Terminals for 230 V AC / 30 V DC Version: 1.4 Date: 2013-03-20 Table of contents Table of contents 1 Foreword 1 1.1 Notes on the documentation
Safety Manual BT50(T) Safety relay / Expansion relay
Safety Manual BT50(T) Safety relay / Expansion relay ABB Jokab Safety Varlabergsvägen 11, SE-434 39, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this document
Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10
Business Audio System: Music & Messaging MP3 Player by Grace Digital Audio User Guide Model No. GDI-USBM10 User Guide Contents Introduction 2 Safety & General Use Information 2 Features 3 Set Up & Operation
EPM3. Phase Sequence and Motor Rotation Tester. Users Manual
EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR
2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.
CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension
High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual
High PoE Midspans NPD-6001A NPD-9501A en Installation Manual High PoE Midspans Table of Contents en 3 Table of contents 1 Safety 4 1.1 About this Manual 4 1.2 Legal Information 4 1.3 Safety Precautions
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws
Compact Pre-wired Photomicrosensor with Built-in Amplifier (Non-modulated) CSM DS_E_7_2 Meeting Customer Needs with Compact Sensors that Mount with M Screws Both light-on and dark-on outputs provided.
Proportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
Infrarot-Bewegungsmelder IP44
Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion
Moxa EtherDevice Switch
Moxa EtherDevice Switch EDS-205 Hardware Installation Guide Third Edition, June 2008 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. P/N: 1802002050000 Overview The
Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011
Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.
Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00
E Refrigerant Charging Unit ICOGD 020AH1000 Operating Manual FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 Contents Technical Specifications... 20 Safety... 21 A/C System... 22 Components... 23 Control Panel...
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
Installing the Broadband Global Area Network (BGAN) Fixed Mount Kit
Installing the Broadband Global Area Network (BGAN) Fixed Mount Kit Product description BGAN fixed mount kit Although the BGAN satellite modem terminal is designed for portable use, the BGAN Fixed Mount
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
Explosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
USER S MANUAL. CompoBus/D (DeviceNet) Communications Unit MODEL 3G3MV-PDRT1-SINV. (For SYSDRIVE 3G3MV Multi-function Compact Inverters)
Cat. No. I529-E1-1 USER S MANUAL CompoBus/D (DeviceNet) Communications Unit MODEL 3G3MV-PDRT1-SINV (For SYSDRIVE 3G3MV Multi-function Compact Inverters) Thank you for choosing a 3G3MV Multi-function Compact
SPL 2-00/-01 OPERATION INSTRUCTIONS
SPL 2-00/-01 OPERATION INSTRUCTIONS Powerline Ethernet Adapter 500 Mbps EN Read and keep Operation Instructions SPL 2-00/-01 Safety Notes Do NOT use this product near water, for example, in a wet basement
DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:
PR100/PR300/PR500 Pressure Logger Operation Contents: Product Applications and Useful Features Product Specifications Operating Instructions / Getting Started DicksonWare Software Specifications Product
Instructions A622 100 Amp AC/DC Current Probe 070-8883-03
Instructions A622 100 Amp AC/DC Current Probe 070-8883-03 Revision A www.tektronix.com 070888303 Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,
USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920
USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920 [This page intentionally left blank] Warning for Your Protection 1. Read these instructions. 2. Keep these
User Guide. HDMI Active Cable Extender. DVI-7370c
User Guide HDMI Active Cable Extender DVI-7370c TABLE OF CONTENTS SECTION PAGE PRODUCT SAFETY...1 PRODUCT LIABILITY...1 1.0 INTRODUCTION...2 2.0 SPECIFICATIONS...3 3.0 PACKAGE CONTENTS...4 4.0 CONNECTING
INSTALLATION GUIDE 1
INSTALLATION GUIDE 1 Setting information MAC-558IF-E address(mac) MAC-558IF-E serial number(id) MAC-558IF-E code(pin) Indoor unit model name Indoor unit serial number Outdoor unit model name Outdoor unit
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
Getting started with
PART NO. CMA113 MADE IN CHINA 1. Measuring CAT II 2. Max. voltage 250V ~ 3. Max. current 71 Amp Getting started with Electricity consumption monitoring single phase for homes and some smaller light commercial
Model 1756 Test Lead Kit
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 1756 Test Lead Kit Gerneral Purpose Test Lead Information Description These test leads allow you
Tablet Management Rack 16
Tablet Management Rack 16 User's Guide Table of Contents Hazard Symbols Review... 2 Components... 2 Charging Set-up... 3-4 LED and Syncing... 4-5 Cleaning and Maintenance... 6 Specifications... 6 Service
RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug. 2011. RIGOL Technologies, Inc.
Quick Guide DS1000CA Series Oscilloscope Aug. 2011 Technologies, Inc. Guaranty and Declaration Copyright 2011 Technologies, Inc. All Rights Reserved. Trademark Information is a registered trademark of
T7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.
y HS5D First in the Industry Miniature Interlock Switches First in the Industry Head Removal Detection Function for Safer Performance (*based on IDEC research, July 09) New Generation Miniature Interlock
Mounting Instructions. Torque Transducer. A0329 3.2 en
Mounting Instructions Torque Transducer T5 T5 Contents 3 Page Safety instructions.............................................. 4 1 Measuring characteristics..................................... 7 2 Mounting.....................................................
Operating Instructions Drill rig DRU160
Operating Instructions Drill rig DRU160 Index 000 / 001 Original operating instructions 10988825 en / 20.10.2009 Congratulations! With a Hydrostress unit from TYROLIT you have chosen a tried and tested
Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973
Series LCD To power supply Electric Actuator Series LCC Stepper Motor Driver LCD Series LX Dedicated Stepper Motor Driver and Positioning Driver Series LCD/LCC PLC Positioning unit (Not incl. To be provided
Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2
R Extended Range Inductive Prox Greater Sensing Distance Offers Greater Design Flexibility H Sensing distances approximately 1.5 to 2 times larger than that of any conventional Sensor H Reduces problems
Introduction. Page 2 / 9
Installation Manual English, US, version 1.1, as of November 13th, 2015 2015 Smappee NV. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their
DLP-PU/E Instruction Manual
Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.
SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program
Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves