Modular/F.R.L. Units

Size: px
Start display at page:

Download "Modular/F.R.L. Units"

Transcription

1 odular/.r.l. nits eries Round type pressure gauge (with color zone) R L 9 29

2 odular.r.l. nits eries Improved visibility for lubricant drip with graduation for lubricant control raduation Improved installation racket with spacer Retainer pacer with bracket Lever pin q ttach the component into the fitting of the spacer with bracket. w Lock the lever pin into the retainer. (temporary installation) mbedded pressure gauge is a standard feature. olt loat type auto drain with excellent operability is used for compact models (/). rain cock is easy-to-use rotary type. Ozone resistant rubber material (R) Improved relief sensitivity e Tighten the bolt. Round type pressure gauge (with color zone) type Red and green zones offer improved visibility of pressure control range. reen indicator Indicator adjusts to highlight preferred range Red indicator ilter Regulator () to 6() ist eparator Regulator to icro ist eparator Regulator to 296 Regulator R() to 6().R.L. nit to 6 ( R L) to 6 ( L) to 6 ( R) to ( R) to ( )

3 eries onfiguration Product x.8 3/ Page ir ilter Regulator Lubricator R L ilter Regulator Lubricator L 6-6 ir ombination ir ilter Regulator R ir ilter ist eparator Regulator R 6 2 R ilter Regulator ist eparator L

4 eries onfiguration Product x.8 3/ Page ir ilter ist eparator icro ist eparator R R R R2 Regulator R R R-6 3 R R6 R R Regulator with ackflow unction R2 R R R-6 R 3 R6 298

5 eries onfiguration Product x.8 3/ Page L L L Lubricator L L L-6 3 L L6 ilter Regulator ilter Regulator with ackflow unction ist eparator Regulator 38 icro ist eparator Regulator imple pecials ystem hort lead times This system enables us to respond to your special needs, such as additional machining, accessory assembly, or modular unit, and deliver such special products as quickly as standard products. Repeat orders Once we receive a imple pecial part number from your previous order, we will process the order, manufacture the product, and deliver it to you. 38 system designed to respond quickly and easily to your special ordering needs. 299 R L 9

6 ir ombination ir ilter Regulator Lubricator to 6 I ymbol ow to Order ir ilter Regulator Lubricator 3 Option/emi-standard: elect one each for a to m. Option/ttachment/emi-standard symbol: hen more than one specification is required, indicate in alphanumeric order. xample) -3-T-36R ote 3) Option emi-standard ttachment Thread type a b c d e f g h loat type auto drain Pressure gauge igital pressure switch heck valve Pressure switch T-interface 3-port valve for residual pressure release et pressure ote ) owl ymbol ote ) ote 2) ote ) ote ) T ote 6) ithout auto drain loat type auto drain (..) loat type auto drain (.O.) escription etric thread () Rc PT 3/ ithout pressure gauge quare embedded type pressure gauge (with limit indicator) Round type pressure gauge (without limit indicator) Round type pressure gauge (with limit indicator) Round type pressure gauge (with color zone) Output: P output / lectrical entry: iring bottom entry Output: P output / lectrical entry: iring top entry Output: PP output / lectrical entry: iring bottom entry Output: PP output / lectrical entry: iring top entry ithout attachment ounting position: RL ithout attachment ounting position: RL ithout attachment ounting position: TRL ithout attachment ounting position: RL. to.8 Pa setting.2 to.2 Pa setting Polycarbonate bowl etal bowl ylon bowl etal bowl with level gauge ith bowl guard ylon bowl with bowl guard ody size 2 6 ote )

7 ir ombination eries to 6 emi-standard i j k l m ilter ote 8) drain port Lubricator lubricant exhaust port xhaust mechanism low direction Pressure unit ymbol ote 9) ote ) ote ) rain guide is PT (applicable to the ) and PT (applicable to the 2 to 6). The auto drain port comes with ø" one-touch fitting (applicable to the 2 to 6). ote 2) rain guide is (applicable to the ) and (applicable to the 2 to 6). ote 3) Option, are not assembled and supplied loose at the time of shipment. ote ) ot available with piping port size: 6. ote ) The bracket position varies depending on the T- interface or pressure switch mounting. ote ) 3 R ithout drain cock Lubricator with drain cock Relieving type on-relieving type low direction: Left to right low direction: Right to left escription ith drain cock rain guide rain guide rain cock with barb fitting: or ø6 x ø nylon tube ame plate and pressure gauge in imperial units: Pa ote 2) Z ame plate, caution plate for bowl, and pressure gauge in imperial units: psi, ote 3) Z igital pressure switch: ith unit conversion function ote 6) The only difference from the standard specifications is the adjusting spring for the regulator. It does not restrict the setting of.2 Pa or more. hen the pressure gauge is attached, a.2 Pa pressure gauge will be fitted. ote ) Refer to hemical ata on page 28 when selecting a case material. ote 8) loat type auto drain: The combination of and is not possible. ote 9) ithout a valve function ote ) etal bowl: The combination of 2 and 8 is not possible. ote ) ilter drain port: hen choosing with, the drain cock of a lubricator will be with barb fittings. ody size 2 6 ote ) ote ) ote ) ote ) ote ) ote ) ote ) ote ) ote ) ote ) ote ) ote ) ote ) ote ) ote ) ote 2) or thread type: and PT. This product is for overseas use only according to the new easurement Law. (The I unit type is provided for use in apan.) The digital pressure switch will be equipped with the unit conversion function, setting to psi initially. Pa and psi are shown together on the pressure unit. ote 3) or options:, 2, 3,. This product is for overseas use only according to the new easurement Law. (The I unit is provided for use in apan.) ote ) : or thread type: and PT only ote ) : elect with options:, 2, 3,. tandard pecifications ir filter omponent Regulator Lubricator R L x.8 /6 R L, R2 L, R L, R L,, R-6 L-6 3/ R L 3/, R L6 R6 L6 ote ) Pressure gauge port size luid ote 2) mbient and fluid temperature Proof pressure ax. operating pressure et pressure range Relief pressure ominal filtration rating Recommended lubricant owl material owl guard Regulator construction ass (kg) ir to 6 (with no freezing). Pa. Pa. to. Pa. to.8 Pa emi-standard et pressure. Pa ote 3) [at relief flow rate of. l/min (R)] µm lass turbine oil (IO 32) Polycarbonate tandard Relieving type ote ) Pressure gauge connection threads are not available for.r.l. unit with a square embedded type pressure gauge or with a digital pressure switch ( to 6). ote 2) to for the products with the digital pressure switch ote 3) ot applicable to the. R L 9

8 eries to 6 low haracteristics (Representative values) ondition: Inlet pressure. Pa x.8 Rc 2 Rc Outlet pressure (Pa) Outlet pressure (Pa) Outlet pressure (Pa) low rate (l/min (R)) 6 low rate (l/min (R)) low rate (l/min (R)).6 Rc.6 Rc -6.6 Rc3/ Outlet pressure (Pa) Outlet pressure (Pa) Outlet pressure (Pa) low rate (l/min (R)) low rate (l/min (R)) low rate (l/min (R)).6 Rc.6 Rc 6.6 Rc Outlet pressure (Pa) Outlet pressure (Pa) Outlet pressure (Pa) low rate (l/min (R)) 6 low rate (l/min (R)) 6 low rate (l/min (R)) Pressure haracteristics (Representative values) Outlet pressure (Pa) Outlet pressure (Pa).2 et point Inlet pressure (Pa).2. et point Outlet pressure (Pa) Outlet pressure (Pa) onditions: Inlet pressure. Pa, Outlet pressure.2 Pa, low rate l/min (R) et point Inlet pressure (Pa) et point 2 Outlet pressure (Pa) Outlet pressure (Pa).2.2. et point Inlet pressure (Pa) et point Inlet pressure (Pa) Inlet pressure (Pa) Inlet pressure (Pa) 2

9 ir ombination eries to 6 Pressure haracteristics (Representative values) Outlet pressure (Pa).2.2. et point Outlet pressure (Pa).2.2. onditions: Inlet pressure. Pa, Outlet pressure.2 Pa, low rate l/min (R) et point 6 Outlet pressure (Pa).2.2. et point Inlet pressure (Pa) Inlet pressure (Pa) Inlet pressure (Pa) pecific Product Precautions e sure to read before handling. Refer to front matters 2 and for afety Instructions and pages 28 to 29 for.r.l. Precautions. aution ounting and djustment. knob cover is available to prevent careless operation of the knob. Refer to page 389 for details. arning Piping. hen mounting a check valve, make sure the arrow (I side) points in the correct direction of air flow. aution ir upply. se an air filter with µm or less filtration rating on the inlet side of the valve to avoid any damage to the seat caused by dust when mounting a 3-port valve for residual pressure release on the inlet side. arning election. loat type auto drain Operate under the following conditions to avoid malfunction. <.O. type> Operating compressor:. k ( l/min (R)) or more. hen using 2 or more auto drains, multiply the value above by the number of auto drains to find the capacity of the compressors you will need. or example, when using 2 auto drains,. k ( l/min (R)) of the compressor capacity is required. Operating pressure:. Pa or more. <.. type> Operating pressure for :. Pa or more. Operating pressure for 3/:. Pa or more. 2. se a regulator or filter regulator with backflow function when mounting a 3-port valve for residual pressure release on the I side to ensure the release of the residual pressure. Otherwise, residual pressure will not be fully released. aution. hen releasing air at the intermediate position using a T- interface on the inlet side of the lubricator, lubricant may back flow. Therefore, releasing air that does not contain traces of lubricant is not possible. To release air that does not contain traces of lubricant, use a check valve ( series) on the inlet side of the lubricator to prevent a backflow of the lubricant. 2. If a residual pressure-release 3-port valve is mounted on the inlet side of the lubricator, causing a backflow of air, it can result in a backflow of oil or damage to internal parts. Please do not use it in this fashion. 3. n.r.l. unit shipped from the plant has its model number labeled. owever, components that are combined together during the distribution process do not have a label on them. R L 9 3

10 O O eries to 6 imensions, P2 (Pressure gauge port size) 2 to 6 P2 (Pressure gauge port size) R2 R2 I Q I Q R Q Q2 R Q rain ir ilter Regulator Lubricator 2 x P () learance for maintenance rain ir ilter Regulator Lubricator L 2 x P () learance for maintenance pplicable model to 6 to 6 to 6 Option quare embedded type pressure gauge igital pressure switch Round type pressure gauge Round type pressure gauge (with color zone) imensions enter of piping enter of piping enter of piping pplicable model, 2 to 6 Optional/emi-standard specifications ith auto drain (..) etal bowl ith drain guide ith auto drain (.O./..) etal bowl etal bowl with level gauge ith drain guide rain cock with barb fitting imensions x.8.o.: lack..: ray ø one-touch idth across flats fitting idth across flats arb fitting pplicable tubing: T tandard specifications P P2 x.8,,,,, 3/ 3/, / ote) quare type pressure gauge Optional specifications igital pressure switch 39 Round type pressure gauge ø26 ø3. ø3. ø Round type pressure gauge (with color zone) ø3. ø3. ø Optional specifications emi-standard specifications racket mount ith auto drain ith barb fitting ith drain guide etal bowl Q Q2 R R ø. ø. ote) or the only, the position of the pressure gauge is above the center of the piping. ø ø ø9 ø9 ø ø ø etal bowl with level gauge

11 ir ombination ilter Regulator Lubricator to 6 I ymbol ow to Order ilter Regulator Lubricator 3 Option/emi-standard: elect one each for a to l. Option/ttachment/emi-standard symbol: hen more than one specification is required, indicate in alphanumeric order. xample) R emi-standard ttachment Option 6 ote 3) Thread type a b c d e f g h loat type auto drain Pressure gauge igital pressure switch heck valve Pressure switch 3-port valve for residual pressure release et pressure ote ) owl ilter regulator ote 8) drain port ymbol ote ) ote 2) ote ) ote 6) ote 9) ote ) ithout auto drain loat type auto drain (..) loat type auto drain (.O.) escription etric thread () Rc PT 3/ ithout pressure gauge quare embedded type pressure gauge (with limit indicator) Round type pressure gauge (without limit indicator) Round type pressure gauge (with limit indicator) Round type pressure gauge (with color zone) Output: P output / lectrical entry: iring bottom entry Output: P output / lectrical entry: iring top entry Output: PP output / lectrical entry: iring bottom entry Output: PP output / lectrical entry: iring top entry ithout attachment ounting position: L ithout attachment ounting position: L ithout attachment ounting position: L. to.8 Pa setting.2 to.2 Pa setting Polycarbonate bowl etal bowl ylon bowl etal bowl with level gauge ith bowl guard ylon bowl with bowl guard ith drain cock rain guide rain guide rain cock with barb fitting: or ø6 x ø nylon tube ody size 6 ote )

12 ir ombination eries to 6 emi-standard i j k l Lubricator lubricant exhaust port xhaust mechanism low direction Pressure unit ymbol 3 R ote ) Z ote 2) Z ote ) rain guide is PT (applicable to the ) and PT (applicable to the to 6). The auto drain port comes with ø" one-touch fitting (applicable to the to 6). ote 2) rain guide is (applicable to the ) and (applicable to the to 6). ote 3) Option, are not assembled and supplied loose at the time of shipment. ote ) ot available with piping port size: 6. ote ) The bracket position varies depending on the pressure switch mounting. ithout drain cock Lubricator with drain cock Relieving type on-relieving type low direction: Left to right low direction: Right to left escription ame plate and pressure gauge in imperial units: Pa ame plate, caution plate for bowl, and pressure gauge in imperial units: psi, igital pressure switch: ith unit conversion function ote 6) The only difference from the standard specifications is the adjusting spring for the regulator. It does not restrict the setting of.2 Pa or more. hen the pressure gauge is attached, a.2 Pa pressure gauge will be fitted. ote ) Refer to hemical ata on page 28 when selecting a case material. ote 8) loat type auto drain: The combination of and is not possible. ote 9) ithout a valve function ote ) etal bowl: The combination of 2 and 8 is not possible. ody size 6 ote 3) ote 3) ote 3) ote 3) ote 3) ote 3) ote ) ote ) ote ) ote ) ote ) ote ) or thread type: and PT. This product is for overseas use only according to the new easurement Law. (The I unit type is provided for use in apan.) The digital pressure switch will be equipped with the unit conversion function, setting to psi initially. Pa and psi are shown together on the pressure unit. ote 2) or options:, 2, 3,. This product is for overseas use only according to the new easurement Law. (The I unit is provided for use in apan.) ote 3) : or thread type: and PT only ote ) : elect with options:, 2, 3,. tandard pecifications omponent ote ) Pressure gauge port size luid ote 2) mbient and fluid temperature Proof pressure aximum operating pressure et pressure range Relief pressure ominal filtration rating Recommended lubricant owl material owl guard Regulator construction ass (kg) ilter regulator Lubricator L x.8 /6. to. Pa. L, ote ) Pressure gauge connection threads are not available for.r.l. unit with a square embedded type pressure gauge or with a digital pressure switch ( to 6). ote 2) to for the products with the digital pressure switch ote 3) ot applicable to the. ir to 6 (with no freezing). Pa. Pa et pressure. Pa ote 3) [at relief flow rate of. l/min (R)] emi-standard.9 L, L,, µm. to.8 Pa lass turbine oil (IO 32) Polycarbonate Relieving type -6-6 L-6 3/ tandard 6 L 3/, 6 6 L R L 9

13 O R2 O eries to 6 imensions, P2 (Pressure gauge port size) P2 (Pressure gauge port size) to 6 2 x P () 2 x P () R2 I Q I Q Q Q2 R Q R rain ilter Regulator Lubricator learance for maintenance rain ilter Regulator Lubricator learance for maintenance pplicable model Option to 6 quare embedded type pressure gauge igital pressure switch to 6 to 6 Round type pressure gauge Round type pressure gauge (with color zone) imensions enter of piping enter of piping enter of piping pplicable model, to 6 Optional/emi-standard specifications ith auto drain (..) etal bowl ith drain guide ith auto drain (.O./..) etal bowl etal bowl with level gauge ith drain guide rain cock with barb fitting imensions x.8.o.: lack..: ray ø one-touch idth across flats fitting idth across flats arb fitting pplicable tubing: T6-6 6 tandard specifications P P2 ote) x.8 /6,,,, 3/ 3/, quare type pressure gauge Optional specifications igital pressure switch Round type pressure gauge ø26 ø3. ø Round type pressure gauge (with color zone) ø3. ø Optional specifications emi-standard specifications racket mount ith auto drain ith barb fitting ith drain guide etal bowl Q Q2 R R ø. ø. ote) The total length of dimension is the length when the filter regulator knob is unlocked. 8 ø ø9 ø9 ø ø etal bowl with level gauge

14 ir ombination ir ilter Regulator to 6 I ymbol ow to Order ir ilter Regulator 3 Option/emi-standard: elect one each for a to j. Option/ttachment/emi-standard symbol: hen more than one specification is required, indicate in alphanumeric order. xample) -3--6R emi-standard ttachment Option 3 ote 3) Thread type a b c d e f g loat type auto drain Pressure gauge igital pressure switch Pressure switch T-interface 3-port valve for residual pressure release et pressure ote ) owl ilter ote 8) drain port ymbol ote ) ote 2) ote ) ote ) T ote ) ote 6) ote 9) ote ) ithout auto drain loat type auto drain (..) loat type auto drain (.O.) escription etric thread () Rc PT 3/ ithout pressure gauge quare embedded type pressure gauge (with limit indicator) Round type pressure gauge (without limit indicator) Round type pressure gauge (with limit indicator) Round type pressure gauge (with color zone) Output: P output / lectrical entry: iring bottom entry Output: P output / lectrical entry: iring top entry Output: PP output / lectrical entry: iring bottom entry Output: PP output / lectrical entry: iring top entry ithout attachment ounting position: R ounting position: TR ithout attachment ounting position: R ounting position: R. to.8 Pa setting.2 to.2 Pa setting Polycarbonate bowl etal bowl ylon bowl etal bowl with level gauge ith bowl guard ylon bowl with bowl guard ith drain cock rain guide rain guide rain cock with barb fitting: or ø6 x ø nylon tube ody size 2 6

15 ir ombination eries to 6 emi-standard ote ) rain guide is PT (applicable to the ) and PT (applicable to the 2 to 6). The auto drain port comes with ø" one-touch fitting (applicable to the 2 to 6). ote 2) rain guide is (applicable to the ) and (applicable to the 2 to 6). ote 3) Option, are not assembled and supplied loose at the time of shipment. ote ) The bracket position varies depending on the T- interface or pressure switch mounting. tandard pecifications omponent ote ) Pressure gauge port size luid h ote 2) mbient and fluid temperature Proof pressure aximum operating pressure et pressure range Relief pressure ominal filtration rating owl material i j owl guard Regulator construction ass (kg) xhaust mechanism low direction Pressure unit ir filter Regulator ymbol R Relieving type on-relieving type low direction: Left to right low direction: Right to left R x.8 /6. to. Pa.6 ote ) The regulator is equipped with a backflow function in this configuration. dditionally, for safety purposes, please check that the pressure in the outlet side is turned to the atmospheric pressure once the pressure in the outlet side is exhausted, by using a pressure gauge, etc. ote 6) The only difference from the standard specifications is the adjusting spring for the regulator. It does not restrict the setting of.2 Pa or more. hen the pressure gauge is attached, a.2 Pa pressure gauge will be fitted. ote ) Refer to hemical ata on page 28 when selecting a case material. ote 8) loat type auto drain: The combination of and is not possible. ote 9) ithout a valve function R, emi-standard. escription ame plate and pressure gauge in imperial units: Pa ote ) Z ame plate, caution plate for bowl, and pressure gauge in imperial units: psi, ote 2) Z igital pressure switch: ith unit conversion function 2 R2, ote ) etal bowl: The combination of 2 and 8 is not possible. ote ) or thread type: and PT. This product is for overseas use only according to the new easurement Law. (The I unit type is provided for use in apan.) The digital pressure switch will be equipped with the unit conversion function, setting to psi initially. Pa and psi are shown together on the pressure unit. ote 2) or options:, 2, 3,. This product is for overseas use only according to the new easurement Law. (The I unit is provided for use in apan.) ote 3) : or thread type: and PT only ote ) : elect with options:, 2, 3,. ote ) Pressure gauge connection threads are not available for.r.l. unit with a square embedded type pressure gauge or with a digital pressure switch ( to 6). ote 2) to for the products with the digital pressure switch ote 3) ot applicable to the. R, R,, ir to 6 (with no freezing). Pa. Pa et pressure. Pa ote 3) [at relief flow rate of. l/min (R)] µm Polycarbonate Relieving type -6-6 R-6 3/ tandard R 3/,. to.8 Pa ody size 2 6 ote 3) ote 3) ote 3) ote 3) ote 3) ote 3) ote 3) ote 3) ote ) ote ) ote ) ote ) ote ) ote ) ote ) 6 R R6 R L 9 3

16 O O eries to 6 imensions, R2 P2 (Pressure gauge port size) 2 to 6 R2 P2 (Pressure gauge port size) I I Q Q2 R Q Q Q R 2 x P () 2 x P () rain ir ilter Regulator learance for maintenance rain ir ilter Regulator learance for maintenance pplicable model to 6 to 6 Option quare embedded type pressure gauge igital pressure switch Round type pressure gauge to 6 Round type pressure gauge (with color zone) imensions enter of piping enter of piping enter of piping pplicable model, 2 to 6 Optional/emi-standard specifications ith auto drain (..) etal bowl ith drain guide ith auto drain (.O./..) etal bowl etal bowl with level gauge ith drain guide rain cock with barb fitting imensions x.8 idth across flats.o.: lack..: ray ø one-touch fitting idth across flats arb fitting pplicable tubing: T tandard specifications P P2 x.8 /6,,,,, 3/ 3/, ote) quare type pressure gauge Optional specifications igital pressure switch 39 Round type pressure gauge ø26 ø3. ø3. ø Round type pressure gauge (with color zone) ø3. ø3. ø Optional specifications emi-standard specifications racket mount ith auto drain ith barb fitting ith drain guide etal bowl Q Q2 R R ø. ø. ote) or the only, the position of the pressure gauge is above the center of the piping. 32 ø ø ø9 ø9 ø ø ø etal bowl with level gauge

17 ir ombination ir ilter ist eparator Regulator to I ymbol ow to Order ir ilter ist eparator Regulator 3 Option/emi-standard: elect one each for a to j. Option/ttachment/emi-standard symbol: hen more than one specification is required, indicate in alphanumeric order. xample) -3--6R ymbol escription ody size 2 ote 3) Option emi-standard ttachment Thread type a b c d e f loat type auto drain Pressure gauge igital pressure switch Pressure switch T-interface 3-port valve for residual pressure release et pressure ote ) owl ilter g ist separator ote 8) drain port h xhaust mechanism ote ) ote 2) ote ) ote ) T ote ) ote 6) ote 9) ote ) ithout auto drain loat type auto drain (..) loat type auto drain (.O.) Rc PT 3/ ithout pressure gauge quare embedded type pressure gauge (with limit indicator) Round type pressure gauge (with limit indicator) Round type pressure gauge (with color zone) Output: P output / lectrical entry: iring bottom entry Output: P output / lectrical entry: iring top entry Output: PP output / lectrical entry: iring bottom entry Output: PP output / lectrical entry: iring top entry ithout attachment ounting position: R ounting position: TR ithout attachment ounting position: R ounting position: R. to.8 Pa setting.2 to.2 Pa setting Polycarbonate bowl etal bowl ylon bowl etal bowl with level gauge ith bowl guard ylon bowl with bowl guard ith drain cock rain guide rain guide rain cock with barb fitting: or ø6 x ø nylon tube Relieving type on-relieving type 3

18 ir ombination eries to ymbol escription ody size 2 emi-standard omponent ote ) Pressure gauge port size luid ote 2) mbient and fluid temperature Proof pressure aximum operating pressure inimum operating pressure et pressure range Relief pressure ominal filtration rating Outlet side oil mist concentration ote 3) Rated flow (l/min (R)) owl material i j owl guard Regulator construction ass (kg) low direction Pressure unit ir filter ist separator Regulator R ote ) rain guide is PT (applicable to the ) and PT (applicable to the to ). The auto drain port comes with ø" one-touch fitting (applicable to the to ). ote 2) rain guide is (applicable to the ) and (applicable to the to ). ote 3) Option, are not assembled and supplied loose at the time of shipment. ote ) The bracket position varies depending on the T- interface or pressure switch mounting. tandard pecifications low direction: Left to right low direction: Right to left ame plate and pressure gauge in imperial units: Pa ote ) Z ame plate, caution plate for bowl, and pressure gauge in imperial units: psi, ote 2) Z igital pressure switch: ith unit conversion function ote ) The regulator is equipped with a backflow function in this configuration. dditionally, for safety purposes, please check that the pressure in the outlet side is turned to the atmospheric pressure once the pressure in the outlet side is exhausted, by using a pressure gauge, etc. ote 6) The only difference from the standard specifications is the adjusting spring for the regulator. It does not restrict the setting of.2 Pa or more. hen the pressure gauge is attached, a.2 Pa pressure gauge will be fitted. ote ) Refer to hemical ata on page 28 when selecting a case material. ote 8) loat type auto drain: The combination of and is not possible. ote 9) ithout a valve function R, emi-standard. 2 R2, ir to 6 (with no freezing). Pa. Pa. Pa. to.8 Pa et pressure. Pa [at relief flow rate of. l/min (R)] : µm, :.3 µm (99.9% filtered particle size) ax.. mg/m 3 ote ) ote ) (R) (.8 ppm).88 R, Polycarbonate Relieving type.9 tandard ote 3) ote 3) ote 3) ote 3) ote ) ote ) ote ) ote ) ote ) etal bowl: The combination of 2 and 8 is not possible. ote ) or thread type: PT. This product is for overseas use only according to the new easurement Law. (The I unit type is provided for use in apan.) The digital pressure switch will be equipped with the unit conversion function, setting to psi initially. Pa and psi are shown together on the pressure unit. ote 2) or options:, 2, 3,. This product is for overseas use only according to the new easurement Law. (The I unit is provided for use in apan.) ote 3) : or thread type: PT only ote ) : elect with options:, 2, 3,. R,, R-6 ote ) Pressure gauge connection threads are not available for.r.l. unit with a square embedded type pressure gauge or with a digital pressure switch ( to ). ote 2) to for the products with the digital pressure switch. ote 3) onditions: ist separator inlet pressure:. Pa; The rated flow varies depending on the inlet pressure. eep the air flow within the rated flow to prevent an outflow of lubricant to the outlet side. ote ) hen the compressor oil mist discharge concentration is mg/m 3 (R). ote ) owl O-ring and other O-rings are slightly lubricated. 3/.83 R L 9 3

19 O O eries to imensions 2 to -6 R2 P2 (Pressure gauge port size) R2 P2 (Pressure gauge port size) Q I I Q Q2 Q Q R 2 x P () R 2 x P () rain ir ilter rain ist Regulator eparator learance for maintenance rain ir ilter rain ist eparator Regulator learance for maintenance pplicable model to -6 Option quare embedded type pressure gauge igital pressure switch Round type pressure gauge Round type pressure gauge (with color zone) imensions enter of piping enter of piping enter of piping pplicable model 2 to -6 Optional/emi-standard specifications ith auto drain (..) etal bowl ith drain guide ith auto drain (.O./..) etal bowl etal bowl with level gauge ith drain guide rain cock with barb fitting imensions x.8 idth across flats.o.: lack..: ray ø one-touch fitting idth across flats arb fitting pplicable tubing: T6 2-6 tandard specifications P P2,,,,, 3/ ote) quare type pressure gauge Optional specifications igital pressure switch 39 Round type pressure gauge ø3. ø3. ø Round type pressure gauge (with color zone) ø3. ø3. ø Optional specifications emi-standard specifications racket mount ith auto drain ith barb fitting ith drain guide etal bowl Q Q2 R R ø. ote) or the only, the position of the pressure gauge is above the center of the piping. 36 ø ø ø9 ø etal bowl with level gauge

20 ir ombination ilter Regulator ist eparator to I ymbol ow to Order ilter Regulator ist eparator 3 Option/emi-standard: elect one each for a to j. Option/ttachment/emi-standard symbol: hen more than one specification is required, indicate in alphanumeric order. xample) -3--6R ymbol escription ody size emi-standard ttachment Option 38 ote 3) Thread type a b c d e f loat type auto drain Pressure gauge igital pressure switch Pressure switch 3-port valve for residual pressure release ilter regulator g ist separator ote 8) drain port h i et pressure ote ) owl xhaust mechanism low direction ote ) ote 2) ote ) ote ) ote 6) ote 9) ote ) R ithout auto drain loat type auto drain (..) loat type auto drain (.O.) Rc PT 3/ ithout pressure gauge quare embedded type pressure gauge (with limit indicator) Round type pressure gauge (with limit indicator) Round type pressure gauge (with color zone) Output: P output / lectrical entry: iring bottom entry Output: P output / lectrical entry: iring top entry Output: PP output / lectrical entry: iring bottom entry Output: PP output / lectrical entry: iring top entry ithout attachment ounting position: ithout attachment ounting position: ounting position:. to.8 Pa setting.2 to.2 Pa setting Polycarbonate bowl etal bowl ylon bowl etal bowl with level gauge ith bowl guard ylon bowl with bowl guard ith drain cock rain guide rain guide rain cock with barb fitting: or ø6 x ø nylon tube Relieving type on-relieving type low direction: Left to right low direction: Right to left

21 ir ombination eries to ymbol escription ody size emistandard j Pressure unit ote ) rain guide is PT (applicable to the ) and PT (applicable to the to ). The auto drain port comes with ø" one-touch fitting (applicable to the to ). ote 2) rain guide is (applicable to the ) and (applicable to the to ). ote 3) Option, are not assembled and supplied loose at the time of shipment. ote ) The bracket position varies depending on the pressure switch mounting. tandard pecifications omponent ote ) Pressure gauge port size luid ote 2) mbient and fluid temperature Proof pressure aximum operating pressure inimum operating pressure et pressure range Relief pressure ominal filtration rating ote 3) Rated flow (l/min (R)) Outlet side oil mist concentration owl material owl guard Regulator construction ass (kg) ilter regulator ist separator ame plate and pressure gauge in imperial units: Pa ote ) Z ame plate, caution plate for bowl, and pressure gauge in imperial units: psi, ote 2) Z igital pressure switch: ith unit conversion function ote ) The regulator is equipped with a backflow function in this configuration. dditionally, for safety purposes, please check that the pressure in the outlet side is turned to the atmospheric pressure once the pressure in the outlet side is exhausted, by using a pressure gauge, etc. ote 6) The only difference from the standard specifications is the adjusting spring for the regulator. It does not restrict the setting of.2 Pa or more. hen the pressure gauge is attached, a.2 Pa pressure gauge will be fitted. ote ) Refer to hemical ata on page 28 when selecting a case material. ote 8) loat type auto drain: The combination of and is not possible. ote 9) ithout a valve function, emi-standard., ir to 6 (with no freezing). Pa. Pa. Pa. to.8 Pa et pressure. Pa [at relief flow rate of. l/min (R)] : µm, :.3 µm (99.9% filtered particle size) 3 ax.. mg/m 3 ote ) ote ) (R) (.8 ppm). Polycarbonate Relieving type,, tandard.38 ote 3) ote 3) ote 3) ote ) ote ) ote ) ote ) etal bowl: The combination of 2 and 8 is not possible. ote ) or thread type: PT. This product is for overseas use only according to the new easurement Law. (The I unit type is provided for use in apan.) The digital pressure switch will be equipped with the unit conversion function, setting to psi initially. Pa and psi are shown together on the pressure unit. ote 2) or options:, 2, 3,. This product is for overseas use only according to the new easurement Law. (The I unit is provided for use in apan.) ote 3) : or thread type: PT only ote ) : elect with options:, 2, 3, ote ) Pressure gauge connection threads are not available for.r.l. unit with a square embedded type pressure gauge or with a digital pressure switch ( to ). ote 2) to for the products with the digital pressure switch ote 3) onditions: ist separator inlet pressure:. Pa; The rated flow varies depending on the inlet pressure. eep the air flow within the rated flow to prevent an outflow of lubricant to the outlet side. ote ) hen the compressor oil mist discharge concentration is mg/m 3 (R). ote ) owl O-ring and other O-rings are slightly lubricated. 3/. R L 9 39

22 O R2 O eries to imensions to -6 P2 (Pressure gauge port size) P2 (Pressure gauge port size) 2 x P () 2 x P () R2 I Q I Q Q Q2 R Q R rain ilter Regulator rain ist eparator learance for maintenance rain ilter Regulator rain ist eparator learance for maintenance pplicable model to -6 Option quare embedded type pressure gauge igital pressure switch Round type pressure gauge Round type pressure gauge (with color zone) imensions enter of piping enter of piping enter of piping pplicable model to -6 Optional/emi-standard specifications ith auto drain (..) etal bowl ith drain guide ith auto drain (.O./..) etal bowl etal bowl with level gauge ith drain guide rain cock with barb fitting imensions x.8 idth across flats.o.: lack..: ray ø one-touch fitting idth across flats arb fitting pplicable tubing: T6-6 tandard specifications P P2 ote),,,, 3/ quare type pressure gauge Optional specifications igital pressure switch Round type pressure gauge ø3. ø Round type pressure gauge (with color zone) ø3. ø Optional specifications emi-standard specifications racket mount ith auto drain ith barb fitting ith drain guide etal bowl Q Q2 R R ø. ote) The total length of dimension is the length when the filter regulator knob is unlocked. 3 ø ø9 ø etal bowl with level gauge

23 ir ombination eries Options/ttachments Options/ttachments Part o. Option ection Pressure gauge ote ) ttachment Type Round type Round type (with color zone) quare ote 2) embedded type igital pressure switch ote ) loat type auto drain pacer tandard.2 to.2 Pa setting tandard.2 to.2 Pa setting tandard.2 to.2 Pa setting P output/iring bottom entry P output/iring top entry PP output/iring bottom entry PP output/iring top entry.o... heck valve ote 6) ote ) Pressure switch ote ) T-interface ote 6) ote ) 3-port valve for residual pressure release ote ) Piping adapter ote ) Pressure switch with piping adapter ote ) ross spacer ote ) or or or 2--R 2--R ote 3) Y Y- - Y- or or or or or 2 Y - ( 2) I- Y2- ( 2) I- 2 3 Y2-2 or 2 or 2 or L L 38 3 Y -( ) 2 I- Y3-( ) I- 3 Y3-2 or or or or or Part no. or or or or or L L 3- [3P- (Pressure gauge cover only)] 3-2 [3P- (Pressure gauge cover only)] I--2-L [I--2- (witch body only)] ote ) I-R-2-L [I-R-2- (witch body only)] ote ) I--6-L [I--6- (witch body only)] ote ) I-R-6-L [I-R-6- (witch body only)] ote ) 8 Y -( 2) 3 I- Y-( 2) I- 3 6 Y- 2 3 or -6 or -6 or -6 or -6 or -6 Y I- Y-( 2) Y- 3 or or or Y6-3 ( ) - 6 or or Y6 I-6 Y6-( 3) 6-6 or 6 or 6 or 6 ote ) in part numbers for a round pressure gauge indicates a type of connection thread. o indication is necessary for R; however, indicate for PT. Please contact regarding the connection thread PT and pressure gauge supply for psi unit specifications. ote 2) Including one O-ring and 2 mounting screws ote 3) tandard pressure gauge ote ) Lead wire with connector (2 m), adapter, lock pin, O-ring ( pc.), mounting screw (2 pcs.) are attached. [ ]: witch body only. lso, regarding how to order the digital pressure switch, please refer to page 388. ote ) inimum operating pressure:.o. type. Pa;.. type. Pa () and. Pa (3/). Please contact for psi and unit specifications. ote 6) or.r.l. units, port sizes without ( ) are standard specifications. ote ) eparate interfaces are required for modular unit. heck alve: (),, check valve with intermediate air release port can be easily installed to prevent a backflow of lubricant when redirecting the air flow and releasing the air on the outlet side of the regulator. Thread type y-pass port size pecifications ymbol escription 2 3 Rc PT ffective area (mm 2 ) 28 e sure to use above check valves when redirecting the air flow on the inlet side of the lubricator. Threads for I and ports are not machined. ody size I I ymbol y-pass port size for redirecting air flow y-pass port size,,, heck valve 3 pplicable model, 2, 2,, ote) ote) pressure switch cannot be mounted on the -6. Refer to the attachment table above for standard by-pass port sizes applicable to the. 32 R L 9

24 eries Pressure witch: () compact integrated pressure switch can be easily installed and facilitates the pressure detection of the line. I I ymbol Pressure switch Option ote) This product is for overseas use only according to the new easurement Law. (The I unit type is provided for use in apan.) pecifications ymbol P ote) X2 X2-P ote) X X-P ote) X2 X2-P ote) luid mbient and fluid temperature Proof pressure aximum operating pressure et pressure range (when O) ysteresis witch haracteristics Lead wire length. m. m. m. m 3 m 3 m 3 m 3 m ontact point configuration aximum contact point capacity Operating voltage:, aximum operating current escription et pressure range. to. Pa. to. Pa. to.6 Pa. to.6 Pa. to. Pa. to. Pa. to.6 Pa. to.6 Pa Pressure display Pa Pa/psi dual scale Pa Pa/psi dual scale Pa Pa/psi dual scale Pa Pa/psi dual scale ir to 6 (with no freezing). Pa. Pa. to. Pa.8 Pa or less a 2 (), 2 () or less 2 to 2, : m 8, : m, : m ote) or detailed specifications on the I series, please refer to series I in est Pneumatics o.6. ody size 6 I- I- I- I- I ote) eparate spacers are required for modular unit. 23 enter of.r.l. body pplicable model 2, -6,, 6 T-interface: (T) x.8,,,, sing a T-interface facilitates the redirection of air flow. Octagon T-interface enter of.r.l. body aution on ounting If a T-interface is used on the I side of the lubricator, lubricant may be mixed. se the series check valve to avoid such possibility. 322 Y- Y2- Y2-2 Y3- Y3-2 Y- 2 Y- 3 Y- 2 Y- 3 Y6-3 Y6- x pplicable model,,, 2, 2, 2,,,,, -6, -6-6,, 6,,, 6 ote ) in model numbers indicates a thread type. o indication is necessary for Rc; however, indicate for PT, and for. ote 2) eparate interfaces are required for modular unit. Refer to the attachment table on page 32 for standard port sizes when using with the

25 ttachments eries Pressure Relief 3 Port alve: () ith the use of a 3-port valve for residual pressure release, pressure left in the line can be easily exhausted. 3 I ymbol () 2 emi-standard: elect one each for a to b. emi-standard symbol: hen more than one specification is required, indicate in alphabetic order. xample) -3-RZ 3 (P) (R) 3-port valve for residual pressure release Thread type low direction ymbol ote) ote) R escription Rc PT 3/ low direction: Left to right low direction: Right to left ody size emistandard ame plate in imperial units: Pa b Pressure unit Z ote) ame plate in imperial units: psi ote) or thread type: PT only. This product is for overseas use only according to the new easurement Law. (The I unit type is provided for use in apan.) pecifications ffective area (mm 2 ) ( ): v factor I, X a -6 3/ 3/. If a tube, stop valve or silencer is connected to the exhaust port of the /, the effective sectional area should be larger than the figure indicated in the following table, to prevent malfunction caused by back pressure. (This is not applicable to the /.) I (.) (.) 6 (.8) 3 (.68) 2 (.6) 38 (2.6) (2.98) (.3) 82 (.) 2 (6.8) ote) se an air filter on the I side for operating protection. aution on ounting X (.6) 6 (.8) (.) 29 (.) 36 (.9) (2.) 2 (2.28) 9 (2.66) (2.) (2.8) ffective area (mm 2 ) ross pacer: x.8,,,, Pipings are possible in all directions. I/ ports are not machined for threads. Please contact if threaded (machined) ports are required. ross spacer aution on ounting. hen mounting a cross interface directly on the I side of the lubricator, be sure to use the series check valve between the lubricator and cross interface. 2. actory mounting of a cross interface on the model is available as a special order : x Rc : ithout thread Y- Y2- Y2-2 Y3- Y3-2 Y- 2 Y- 3 Y- 3 Y I P ø X. 8 6 enter of.r.l. body x ø Lockable at the time of exhaust pplicable model 2, -6 ote ) in model numbers indicates a thread type. o indication is necessary for Rc; however, indicate for PT, and for. ote 2) If threaded I/ ports are required, they are available as a special order. Please contact R L 9

26 eries Piping dapter: x.8,,,,, 3/, piping adapter allows installation/removal of the component without removing the piping and thus makes maintenance easier. Piping adapter Pressure witch with Piping dapter I 3 enter of.r.l. body ote ) x.8 3/ 3/ 3/ pplicable model,,, R, L, R, L,,,, 2,, R, L,,,,, R, L,,, -6, -6, R -6, -6, L-6, -6, -6,, 6, 6,, 6,, 6, R R6, L, L6, 6 ote ) in model numbers indicates a thread type. o indication is necessary for Rc; however, indicate for PT, and for. ote 2) eparate interfaces are required for modular unit. actory mounting of a piping adapter on the models is available as a special order I ymbol ote) or thread type: PT only. This product is for overseas use only according to the new easurement Law. (The I unit type is provided for use in apan.) pecifications luid mbient and fluid temperature Proof pressure aximum operating pressure et pressure range (when O) ysteresis witch haracteristics ontact point configuration aximum contact point capacity Operating voltage:, aximum operating current 32 Thread type ccessory ymbol ote) ote) ymbol X2 P ote) X2-P ote) X2 X22 X2-P ote) X22-P ote) X X2 X-P ote) X2-P ote) X2 X2 X2-P ote) X2-P ote) Lead wire length. m. m. m. m. m. m. m. m 3 m 3 m 3 m 3 m 3 m 3 m 3 m 3 m Regulating pressure range. to. Pa. to. Pa. to. Pa. to. Pa. to.6 Pa. to.6 Pa. to.6 Pa. to.6 Pa. to. Pa. to. Pa. to. Pa. to. Pa. to.6 Pa. to.6 Pa. to.6 Pa. to.6 Pa ir to 6 (with no freezing). Pa. Pa. to. Pa.8 Pa or less a 2(), 2() or less 2 to 2, : m 8, : m, : m escription Rc PT 3/ Pressure display Pa Pa Pa/psi dual scale Pa/psi dual scale Pa Pa Pa/psi dual scale Pa/psi dual scale Pa Pa Pa/psi dual scale Pa/psi dual scale Pa Pa Pa/psi dual scale Pa/psi dual scale ounting position Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left ote ) I- I- 2 I- 3 I- 2 I- 3 I- I- 2 I- 3 I- I- 6 3/ ody size Left Right Pressure switch with piping adapter 23 enter of.r.l. body pplicable model R,, 2, R2, R,, ote 2) R,, ote ) in the model numbers indicates a thread type. o indication is necessary for Rc; however, indicate for PT, and for. ote 2) annot be mounted on the -6 and -6. ote 3) eparate interfaces are required for modular unit. The pressure switch on the -6 and above and the -6 can be mounted by screwing I- into the piping adapter - 6-X or 6-6-X to 6- -X (with top-face thread Rc ). Products with a premounted switch are available as a special order. Please contact regarding their availability

27 eries pacers/rackets ccessories pacer enter of.r.l. body Y Y RL 2 X-X Y Y Y Y Y Y pplicable model,, 2, -6,, 6, 6,, 6 eal X (pacer width) Replacement Parts escription eal aterial Y R ote 2) Y YP-6 ote ) YP-6 Part no. Y Y YP-6 YP-6 Y YP-6 Y6 Y6P-6 ote ) ssembly of 2 O-rings ote 2) R is used for Y spacer because of no direct contact with fluid. pacer with racket ø YT YT YT YT YT Y6T YT Replacement Parts escription eal 6 6 YT aterial YT R ote 2) (YT, YT only) 2 33 YT YP-6 ote ) ote ) ssembly of 2 O-rings ote 2) R is used for YT spacer because of no direct contact with fluid. RL YP-6 ø (YT, YT only) YT YP-6 eal Part no. 2 X X enter of.r.l. body X-X (pacer width) pplicable model 2, -6,, 6,, 6,,, 6 YT YP-6 YT YP-6 Y6T Y6P-6 R L 9 32

28 3 2 ounting Position for pacer with racket T T T ttachment T T T T T ttachment T T T ttachment ttachment T T T ttachment ttachment : imensions from the end of the I side to the center of the mounting hole for the first bracket. 2: ounting hole pitch between the first and the second brackets. 3: ounting hole pitch between the second and the third brackets. : ounting hole pitch between the third and the fourth brackets. 3-port valve for residual pressure: heck valve: Pressure switch: T-interface: T I racket I racket P. 326 eries

29 P93-I Issued: ep 9 orporation of merica oulevard oblesville, I 66 P.. Information poxy oated.r.l.nits 2/3-***-*-X22 //-***-*-X R//-***-*-X8 L//-***-*-X //-***-*-X8 //-***-*-X Y//*-T pplication: eature : eature 2: ir preparation in an environment that requires enhanced corrosion protection. ie cast aluminum components are epoxy coated for improved chemical resistance. teel external hardware is replaced with stainless steel for improved chemical resistance. omparison with tandard Product: ) unctional performance is equivalent to standard product. 2) Product withstood salt spray testing per T - with excellent results (ee test results on page 2). Improved performance vs. other chemicals is anticipated but has not been verified. pplications: arine environments ater splash zone in various processes ashdown in food plants (non-food or splash zone only) Related Products: Q eries - 36 One-touch ittings - oming oon: Q2 Q2 eries - i plated brass One-touch ittings (oming oon) eries - 36 One-touch peed ontrols eries - repairable ylinder eries with X69 option - crimped body ylinder, domestic interchange eries - crimped body ylinder Y eries - luminum body ygienic esign ctuators

30 .R.L. nit eries 2~ ow To Order Y Z - X22 ir ombination nit ith xternal poxy oating, tainless asteners ody ize ymbol 2 3 ize ombination ymbol / ssembly Order R L L R Port ize ymbol 2 3 Port ize PT Threads pplicable ody ize 2 3 ote: Other sizes, thread forms, options, etc. may be possible, please contact for availability. pecifications ody size Operating specifications uto drain port (, ) owl type (, L, ) ody material owl material (, L, ) ody, owl surface treatment onnet (R, ) anual drain (, ) xternal screws Individual mounting brackets Panel mount nut (R, ) onnector brackets () ill plug (L) ight dome (L) ight glass hardware (,L,) owl ymbol 2 8 ame Plate, aution Plate On owl in psi, escription etal owl etal owl ith ight lass Residual Pressure Relief alve ymbol escription ithout alve ith ownstream alve ccessories ymbol Regulator andle Orientation ymbol escription ownward andle Y pward andle escription one loat uto rain (..) loat uto rain (.O.) pplicable ody ize 2 3, pplicable ombo ll ll pplicable ody ize ll 3, 3, 2 3 ame as standard - see catalog -2 or 6 PT PT PT / PT etal etal with sight gauge ie cast aluminum ie cast aluminum poxy resin coating Polyacetal PO tainless steel poxy coated steel PO ie cast zinc (epoxy coated) tainless steel Polycarbonate tainless steel imensions - Refer to drawings on page 3 * ** Q 2 33 mm 3. * ithout relief valve option ** ith relief valve option * 9 ** Q mm * ithout relief valve option ** ith relief valve option * 9 ** Q 2 33 mm 3. * ithout relief valve option ** ith relief valve option 2

31 eries 2~.R.L. nit (2) - P (Port ize) Q Q I P2 (auge Port ize) racket and Relief alve (Optional) in. learance or aintenance - owl etail (/) (2) - P (Port ize) Q Q I P2 (auge Port ize) racket and Relief alve (Optional) ote: ight glass not applicable to all size bowls. in. learance or aintenance - (2) - P (Port ize) Q Q I P2 (auge Port ize) racket and Relief alve (Optional) in. learance or aintenance otes: ilter & ilter Regulator owls depict manual drain, see individual sections for details with auto-drain options. 3

32 ilter eries ~ ow To Order 3 8 Z - X ody ize ymbol Port ize ymbol 2 3 ilter ize Port ize PT Threads pplicable ody ize ote: Other sizes, thread forms, options, etc. may be possible, please contact for availability. owl ymbol 2 8 ccessories ymbol * ith xternal poxy oating, tainless asteners ame Plate, aution Plate On owl in psi, escription etal owl etal owl ith ight lass escription one ounting racket loat uto rain (..) loat uto rain (.O.) pplicable ody ize, pplicable ody ize ll ll,, *ote: racket is not assembled and is supplied loose at time of shipment. pecifications ody size Operating specifications uto drain port owl type ody material owl material ody, owl surface treatment anual drain (, ) xternal screws Individual mounting brackets ight glass hardware ame as standard - see catalog -2 or 6 PT PT PT / PT etal etal with sight gauge ie cast aluminum ie cast aluminum poxy resin coating PO tainless steel poxy coated steel tainless steel imensions - Refer to drawings on page tandard Port ize PT PT PT imensions L P Q R T X. X. X.8 3. mm ounting racket it (Optional) P--X P--X P--X uto rain Port ize PT PT imensions L P Q R 6 T X. X.8 3. mm ounting racket it (Optional) P--X P--X

33 eries ~ ilter tandard (anual rain) P R T RT OTI TR Q owl etail () I L racket (Optional) ith uto rain R P T RT OTI TR Q I ote: ight glass not applicable to. L racket (Optional) PT

34 ilter - Regulator eries ~ ow To Order 3 8 Z - X8 ilter - Regulator ody ize ymbol Port ize ymbol 2 3 ize Port ize PT Threads pplicable ody ize ote: Other sizes, thread forms, options, etc. may be possible, please contact for availability. pecifications ody size Operating specifications uto drain port owl type ody material owl material ody, owl surface treatment onnet anual drain (, ) xternal screws Individual mounting brackets Panel mount nut ight glass hardware owl ymbol 2 8 ccessories ymbol * * ith xternal poxy oating, tainless asteners ame Plate, aution Plate On owl in psi, escription etal owl etal owl ith ight lass escription one ounting racket loat uto rain (..) loat uto rain (.O.) Panel ount ut pplicable ody ize, pplicable ody ize ll ll,, ll *ote: racket and/or panel mount nut are not assembled and are supplied loose at time of shipment. ame as standard - see catalog -2 or 6 PT PT PT / PT etal etal with sight gauge ie cast aluminum ie cast aluminum poxy resin coating Polyacetal PO tainless steel poxy coated steel PO tainless steel ccessories ounting racket it (Optional) P-2-X RP-2-X RP-2-X Panel ounting ut (Optional) RP-26 RP-26 RP-26 imensions - Refer to drawings on page tandard Port ize PT PT PT auge Port PT PT PT (max.3) 83(max.86) 88(max.92) 3.. (max.6) 28(max.22) 2(max.29) imensions L Q T X 28 X 38 X. 2 X. Y 3. Z mm uto rain Port ize PT PT auge Port PT PT (max.86) 88(max.92) (max.22) 2(max.2) imensions L Q T X 38 X. 2 X. Y 3. Z 9 2 mm

35 eries ~ ilter - Regulator tandard (anual rain) I PL ITTI T X Z L owl etail () racket and ounting ut (Optional) I Y Q ote: ight glass not applicable to. 2 - ith uto rain PL ITTI I Z T X L racket and ounting ut (Optional) I Y Q 2 -

36 Regulator eries R~ ow To Order R 2 Y Z - X8 ody ize ymbol Regulator ize PT Threads andle Orientation ymbol escription andle own Y andle p ith xternal poxy oating, tainless asteners ame Plate, aution Plate On owl in psi, ote: Other sizes, thread forms, options, etc. may be possible, please contact for availability. Port ize ymbol 2 3 imensions R R R Port ize Port ize PT PT PT pplicable ody ize auge Port PT PT PT pecifications ody size Operating specifications ody material ody, owl surface treatment onnet Individual mounting brackets Panel mount nut (max.9) 3(max.6) 2(max.28) L 6 66 ccessories ymbol * * escription one ounting racket Panel ount ut ame as standard - see catalog -2 or 6 PT PT PT ie cast aluminum poxy resin coating Polyacetal poxy coated steel PO imensions P Q T *ote: racket and/or panel mount nut are not assembled and are supplied loose at time of shipment. 28 X 38 X. 2 X. X 6 Y 9 2 Z mm 2 3. ccessories R R R ounting racket it (Optional) RP-2-X8 RP-2-X8 RP-2-X8 Panel ounting ut (Optional) RP-26 RP-26 RP I Q P T PL ITTI racket and ounting ut (Optional) I X Y Z Plate Thickness R, : ax 3. R: ax 8

37 8 2 eries L~ Lubricator ody ize ymbol Lubricator Port ize ymbol 2 3 imensions Port ize L PT L PT L PT ize Port ize ow To Order L 2 2 Z - X PT Threads pplicable ody ize pecifications ody size Operating specifications owl type ody material owl material ody, owl surface treatment Individual mounting brackets ill plug ight dome ight glass hardware owl ymbol 2 8 ccessories ymbol * ame Plate, aution Plate On owl in psi, escription etal owl etal owl ith ight lass escription one ounting racket ith xternal poxy oating, tainless asteners pplicable ody ize, pplicable ody ize ll ll *ote: racket is not assembled and is supplied loose at time of shipment. ote: Other sizes, thread forms, options, etc. may be possible, please contact for availability. ame as standard - see catalog -2 or 6 PT PT PT etal ie cast zinc etal with sight gauge ie cast aluminum ie cast aluminum poxy resin coating poxy coated steel tainless steel Polycarbonate tainless steel imensions L P Q R T X. X. X.8 3. mm ounting racket it (Optional) P--X P--X P--X R P T RT OTI TR Q I L racket (Optional) ight glass assy not applicable to L 9

38 ccessories Residual Pressure Relief 3 Port alve () ith the use of a 3 port valve for residual pressure release, pressure left in the line can be easily exhausted. Ø 2-Ø I ymbol () 2 Lockable at the time of exhaust 3 (P) (R) Port ize I, X ffective area mm 2 (v) I to to X (.) 6 (.8) 3 (.68) 29 (.) (2.98) 2 (2.28) Paint color (tandard) andle: Red ody: Platinum silver se an air filter on the I side for operating protection. I ow To Order Residual Pressure Relief 3 Port alve ody ize ymbol 2 Z - X ody ize pplicable 2 3 ymbol Port ize 2 3 Thread Type PT ody ize ote: Other sizes, thread forms, options, etc. may be possible, please contact for availability. ith xternal poxy oating, tainless asteners ame Plate In Imperial nits (PI, ) imensions 9 8 X I aution If a stop valve or a silencer is connected to the exhaust port of /, the effective sectional area should be larger than the figure indicated in the following table, to prevent malfunction caused by back pressure. (This is not applicable to ) ffective area (mm 2 ) If unit is to be used in a washdown application, avoid directing fluid into the exhaust port. mm 63

39 ccessories pacer poxy oated luminum, tainless crews, R eals.r.l. center imensions mm Y-T Y-T Y-T Interface ith T racket poxy oated luminum, tainless crews, R eals Interface with T-type bracket T-type bracket.r.l. ody center R L imensions Interface ith T racket YT-T YT-T YT-T R L pplicable s *-X22 3*-X22 *-X22 mm Other vailable ir Line Products with poxy oating/tainless ardware eries () R-6 L - * Y* Y* escription oft tart alve ater Removal ilter Regulator with tainless T-handle, aluminum bonnet for resistance oft tart alve with Pilot Lock-Out ilter-regulator with tainless T-handle, aluminum bonnet for resistance Piping dapter T Interface ross Interface Option ode X X229 X X X X X T3 Please contact for ordering information

40 alt pray Test Results (for reference). Test onditions ) ethod: In compliance with T -a (I Z 23), leave parts in a salt spray test chamber, and compare rust generation. 2) onditions: Temperature: 9 ( ) alt ater oncentration: % 3) Time: hours [requency: hr, 2hrs, 8hrs, 2hrs, 96hrs, 68hrs, 2hrs, hrs, hrs, hrs] ) amples: Parts for and (ee igure.) Part descriptions: parts () ody (2) rain cock (3) mall screw for level gauge () onnet screw Types: 2 Types ) tandard ) pecial X (oated with epoxy resin [xternal metal parts are made of ]) Refer to Table for part materials and treatments. *Quantity; 2 pieces for each 2. Test Results Table alt spray resistance test results o. escription Type aterial & Treatment Results 2 ody rain cock tandard aterial: ie ast luminum Treatment: Platinum oating aterial: ie ast luminum pecial X Treatment: Platinum & poxy oating aterial: ie ast luminum tandard Treatment: Zinc hromate pecial X aterial: Rusted in hrs Part of coating swelled ot rusted in hrs Part of coating swelled Rusted in 2hrs ot rusted in hrs 3 ross recessed round head screw for metal bowl with level gauge tandard pecial X aterial: teel Treatment: ickel Plating aterial: Rusted in 2hrs ot rusted in hrs 3 elf-tapping screw for R and bonnet tandard pecial X aterial: teel Treatment: Zinc hromate aterial: Rusted in 2hrs ot rusted in hrs 2 igure ody crew tandard X poxy Resin oating tandard X tainless teel tandard rain ock X tainless teel aution! To ensure the safest possible operation of this product, please be sure to read thoroughly the afety Instructions in our est Pneumatics catalog before use. 9 orporation ll Rights Reserved 2

Series AF. Modular Type Air Filters AR AL AW A G AV AF10 AF20 AF30 AF40 AF40-06 AF50 AF60 AFM20 AFM30 AFM40 AFM40-06 AFD20 AFD30 AFD40 AFD40-06

Series AF. Modular Type Air Filters AR AL AW A G AV AF10 AF20 AF30 AF40 AF40-06 AF50 AF60 AFM20 AFM30 AFM40 AFM40-06 AFD20 AFD30 AFD40 AFD40-06 Modular Type ir ilters eries ir ilter eries 0 M x 0. iltration (μm) Options /, /4 /4, -06 /4,, / 3/4 racket loat type auto drain 3/4, Page 3 through to 336 60 Mist eparator eries M M /, /4 M M /4, /4,,

More information

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C Water droplet removal Water Separator Water droplet separation rate: % Model Flow capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure 300 750 1,500 AMG 2,0 AMG to AMG/ Large dust particle

More information

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves U/ / or / > > Sub-base mounted, 99- s,, or > > Steel reinforced main seals > > Low power coils (,W) > > Wide range of sub-bases and accessories > > 6 bar and bar NOO solenoid pilots with locking or non-locking

More information

FRL/AirCare Air Controls & Accessories

FRL/AirCare Air Controls & Accessories FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor

More information

Series IDU/IDF. Refrigerated Air Dryer

Series IDU/IDF. Refrigerated Air Dryer Refrigerated ir ryer Series IU/IF The models IF1 to 11 and IU3 to 6 have been revised. For details, refer to catalog no. S30-8. Similar updating for other IF/IU models is scheduled to follow shortly. In

More information

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted U/ / & / valves, solenoid and pilot actuated ISO 99-, ISO size,, & Sub-base mounted Steel reinforced main seals 6 bar and bar NOO solenoid pilots with locking or non-locking manual override Low power coils

More information

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100. Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.

More information

Filter/Regulators Compressed air, general purpose, and Instrument Filter/Regulators 1/8" to 1-1/2" port sizes

Filter/Regulators Compressed air, general purpose, and Instrument Filter/Regulators 1/8 to 1-1/2 port sizes Section 12 Filter/Regulators Compressed air, general purpose, and Instrument Filter/Regulators 1/8" to 1-1/2" port sizes B7 Miniature eneral Purpose Filter/Regulator 1/8" and 1/" ports...................................le-12-2

More information

Compact cylinder Double acting single rod type. SSD SSD-L (with switch) Double acting Compressed air 1.0. 1.6-10 to 60 (no freezing) Rc1/8 Rc1/4 Rc3/8

Compact cylinder Double acting single rod type. SSD SSD-L (with switch) Double acting Compressed air 1.0. 1.6-10 to 60 (no freezing) Rc1/8 Rc1/4 Rc3/8 * U S 4 Specifications escriptions Bore size mm Actuation Working fluid ax. working pressure Pa in. working pressure Pa Withstanding pressure Pa Ambient temperature Port size Stroke length Rubber cushioned

More information

Series M Applicable Tubing: ø2 Connection Thread: M3, M5

Series M Applicable Tubing: ø2 Connection Thread: M3, M5 iniature Fittings Series pplicable Tubing: ø2 onnection Thread:, RoHS ade to Order (Refer to page for details.) pplicable O.D. x I.D.: ø2 x ø.2 onnection thread: / One-touch fitting size: ø.2 / ø Tubing

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

VG2000 Series Cast Iron Flanged Globe Valves

VG2000 Series Cast Iron Flanged Globe Valves VG2000 Series ast Iron Flanged Globe Valves Installation Instructions Part No. 14-1161-106, Rev. Issued November 15, 2013 Supersedes June 15, 2007 pplications VG2000 Series ast Iron Flanged Globe Valves

More information

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S. Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical

More information

FILTER TECHNICAL DATA COMPONENTS

FILTER TECHNICAL DATA COMPONENTS TR The Job of the filter is to remove any solid or liquid impurities from the air generated by the compressor. ncoming air is rotated by the centrifuge unit. The heaviest liquid and solid particles are

More information

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40 Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane

More information

LSB Series. Valve Position Monitor. www.powergenex.com. All innovation on driving your valve automation

LSB Series. Valve Position Monitor. www.powergenex.com. All innovation on driving your valve automation LS Series Valve Position Monitor ll innovation on driving your valve automation www.powergenex.com LS-1000 Series Valve Position Monitor Robust valve position monitor with a good recognizable beacon, various

More information

Control Stations Made of Polyester Resin Series 8146

Control Stations Made of Polyester Resin Series 8146 ontrol Stations Made of Polyester Resin www.stahl.de > s made of glass-fibre reinforced polyester resin > 8 basic enclosure sizes with various enclosure heights > an be combined to larger units > Equipped

More information

VOYAGER 570G. 744A Sprayer Control

VOYAGER 570G. 744A Sprayer Control VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4 SPOO & SV VAVS monostable / bistable function threaded ports -G 1/ 5/-5/3 Series 1 FATURS Reliability: steel spool & sleeve technology with long service life Robust valve design, particularly recommended

More information

CEILING CASSETTE FAN COIL UNIT

CEILING CASSETTE FAN COIL UNIT CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

Now Available in Black Zinc Nickel

Now Available in Black Zinc Nickel 847/848 Series Power Supply up to 63 Now vailable in lack Zinc Nickel The 847/848 bayonet Series has been especially designed for light and harsh environment. Its physical characteristics and performances

More information

Series NCM. Air Cylinder. Stainless Steel Body Cylinders 7/16", 9/16", 3/4", 7/8", 1-1/16", 1-1/4", 1-1/2", 2" Bore

Series NCM. Air Cylinder. Stainless Steel Body Cylinders 7/16, 9/16, 3/4, 7/8, 1-1/16, 1-1/4, 1-1/2, 2 Bore CT.ID2-2 ir Cylinder Series CM Stainless Steel ody Cylinders 7/16", 9/16", 3/4", 7/8", 1-1/16", 1-1/4", 1-1/2", 2" ore ow available in 7/16" and 9/16" bore Double Rod/Double End Mounting on-rotating Rod

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.

More information

Return line filters. Return line filters

Return line filters. Return line filters Return line filters Return line filters Index Technical data - 5 Filters series 6 Filters series --3 8 ccessories Spare parts Uni-ardan Italia S.p.. reserves the right to make technical changes to the

More information

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00. Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the

More information

POWER PULSE VALVES remote pilot threaded or Quick Mount connection 3/4 to 1 1/2

POWER PULSE VALVES remote pilot threaded or Quick Mount connection 3/4 to 1 1/2 POWR PULS VLVS pilot threaded or Quick Mount 3/4 to 1 1/2 N 2/2 Series 353 TURS The piston cartridge pulse valves are especially designed for dust collector service applications, combining high flow, long

More information

RUBBER SLEEVE KNIFE GATE VALVE

RUBBER SLEEVE KNIFE GATE VALVE RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a wafer valve designed for a wide range of industrial applications. The double-seated design provides bi-directional shut off. The design of the valve

More information

Series 30000 Hose Reels

Series 30000 Hose Reels Operating Instructions and Parts List for Series 30000 Hose Reels - MANUAL DRIVEN - - POWER DRIVEN - SAFETY PRECAUTIONS Personal injury and/or equipment damage may result if proper safety precautions are

More information

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS PNEUMATIC SAFETY CONTROLS BASIC CONTROLS SC3000 - SELF CONTAINED 2 HAND CONTROL - STAND ALONE MODEL SC3300 - SELF CONTAINED 2 HAND CONTROL - PRESS READY

More information

indirect electro-pneumatic, pneumatic, manual, mechanical pneumatic spring, mechanical spring G1/8 6,5 890

indirect electro-pneumatic, pneumatic, manual, mechanical pneumatic spring, mechanical spring G1/8 6,5 890 L-M UNVRSL istributors / - / - UNVRSL Modular System: possibility to create a lot of different valves with a short number of basis elements - ontrol: manual, mechanical,, electric - Traditional UNVR spool

More information

High Flow High Pressure Solenoid Valve. Double 3/2 N.C. solenoid valve with manual override

High Flow High Pressure Solenoid Valve. Double 3/2 N.C. solenoid valve with manual override Double 3/2 N.C. solenoid valve with manual override General The high pressure/high flow capacity solenoid valve, as not available on the market, was especially engineered by BIFFI in the early '70s for

More information

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional

More information

Stainless Steel Single and Dual Circulation Kits

Stainless Steel Single and Dual Circulation Kits Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating

More information

Limit Switches/ Receptacle Assembly... For Nuclear Environments

Limit Switches/ Receptacle Assembly... For Nuclear Environments 180-302/402 Series Inside ontainment reas TM Limit Switches/ Receptacle ssembly... or Nuclear nvironments eatures: Qualified to I s 344-1975, 323-1974, and 382-1972. Manufactured to a quality assurance

More information

Table of Contents Introduction... 2 Amphenol MIL-DTL-5015 and MIL-5015 Type Standard Cylindrical Connectors General Information, Class

Table of Contents Introduction... 2 Amphenol MIL-DTL-5015 and MIL-5015 Type Standard Cylindrical Connectors General Information, Class able of ontents age Introduction...................................... 2 mphenol I--5015 and I-5015 ype tandard ylindrical onnectors eneral Information, lass esignations............................. 3

More information

TECHNICAL DATA. Dry 122a. November 12, 2013

TECHNICAL DATA. Dry 122a. November 12, 2013 Dry 122a 1. PRODUCT DESCRIPTION The Viking is a quick-opening device. When installed with the required external Anti-flood Device, the assembly is designed to increase the operating speed of Viking Model

More information

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications Speed Controller with One-touch Fitting Stainless Steel Series Elbow Type/Universal Type Series -FG RoHS Stainless specifications for use in corrosive environments. Stainless steel used for metal parts.

More information

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

AIR-AIR PRESSURE MULTIPLIER (BOOSTER) AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally

More information

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide 2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620 Quick Installation Guide Table of Contents Verify The Contents Inside Package Box... 3 Physical Installation... 4 Further Configuration...12 Verify

More information

Richter Twin Piston Quarter-turn Actuators

Richter Twin Piston Quarter-turn Actuators Richter Twin Piston Quarter-turn ctuators R ompact Powerful Maintenance-free R ouble-acting quarter-turn actuators The actuators are the optimum automation units in technical and commercial terms for Richter

More information

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3 Port Solenoid Valve 00/00/00 Metal Seal Rubber Seal 0. 0.9 (Standard) (High pressure type, High speed response type) Power consumption: 0. W/0.9 W Compact, High Flow Body ported Base mounted 00 00 00 00

More information

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Valve Series VN Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

3/2-way Mini Solenoid Valve

3/2-way Mini Solenoid Valve 3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug

More information

CutMaster 82. 6.04 Major External Replacement Parts

CutMaster 82. 6.04 Major External Replacement Parts CutMaster 8 6.0 Major External Replacement Parts Item # Qty Description Catalog # Cover with labels 9-08 Base Enclosure Assembly 9-08 Tube, roll handle 9-0 Front Panel 9-07 Rear Panel 9-00 Art # A-080

More information

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual

More information

Model 43AP Pneumatic Controller, Style B

Model 43AP Pneumatic Controller, Style B Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set

More information

6 Crankcase Ventilation

6 Crankcase Ventilation 6 Crankcase Ventilation Introduction... 6-3 Crankcase Ventilation Manager (CVM)... 6-5 Introduction... 6-6 CVM280B..................................... 6-7 CVM280T... 6-10 CVM424B....................................

More information

Membrane air dryers MS-LDM1, MS series

Membrane air dryers MS-LDM1, MS series Membrane air dryers MS-LDM1, MS series Membrane air dryers MS-LDM1, MS series Product range overview MS series service units Type Size Pressure regulation range [bar] Grade of filtration [μm] Pneumatic

More information

MÁQUINAS AGRÍCOLAS JACTO S.A. EDITION

MÁQUINAS AGRÍCOLAS JACTO S.A. EDITION AJ English version EDITION - 06/007 CODE - 9790 Parts catalog MÁQUINAS AGRÍCOLAS JACTO S.A. Rua Dr. Luiz Miranda, 650 7580-000 - Pompéia - SP - Brasil Tel.: +55 4 3405-00 - Fax: +55 4 345 306 E-mail: [email protected]

More information

ROUGHNECK II Pumpless Drain

ROUGHNECK II Pumpless Drain SERVICE BULLETIN SB4027 Rev. I 1/11 For Used Oil Only ROUGHNECK II Pumpless Drain Model #4110-022 FOR USED OIL ONLY (Black) For Antifreeze Only Model #4110-023 FOR USED ANTIFREEZE ONLY (Green) Patent #

More information

Valve systems Base plates, according to standard ISO 5599-1. Brochure

Valve systems Base plates, according to standard ISO 5599-1. Brochure ISO 5599-1 Brochure 2 ISO 5599-1 Single subbase Single subbase, thread connections on the side standard: ISO 5599-1 Frame size: ISO 1 - ISO 4 compressed air connection output: G 1/4 - G 1 Reversed pressure

More information

Oil Sight Glass BENEFITS

Oil Sight Glass BENEFITS 8 L-4090 Schroeder es provide maintenance and lubrication management professionals a complete and immediate visual oil analysis. Constructed of durable cast acrylic, they withstand most petroleum products

More information

POWERS Controls No. 4 Pneumatic Damper Actuator

POWERS Controls No. 4 Pneumatic Damper Actuator POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000

More information

STC 3S012-020-A Series Solenoid Valves

STC 3S012-020-A Series Solenoid Valves STC 3S012-020-A Series Solenoid Valves 3S012-020-A Series Solenoid Valve Specifications Valve Model 3S012-1/8-A 3S012-1/4-A 3S020-1/8-A 3S020-1/4-A Port Size (NPT) 1/8 1/4 1/8 1/4 Valve Type Action 3 Way,

More information

High Pressure Equipment High Pressure Valves, Fittings and Tubing

High Pressure Equipment High Pressure Valves, Fittings and Tubing igh quipment igh Valves, ittings and Tubing 0,000, 40,000 and psi service igh quipment Company has developed a line of igh products to assure safe and easy plumbing for 0,000, 40,000 and psi. These needle

More information

300 Series PA Pump and Cooler Assemblies

300 Series PA Pump and Cooler Assemblies Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400. Industrial Filters Accumulators. Filters for inline installation for continuous operation

Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400. Industrial Filters Accumulators. Filters for inline installation for continuous operation Industrial Filters Accumulators Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400 Filters for inline installation for continuous operation With integrated pressure equalisation valve Optimised flow

More information

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 S Single Temperature Room Thermostat Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional

More information

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual OHIO MEDICAL CORPORATION Medical Gas Panel Installation and Maintenance Manual P/N 255105 (Rev.5) 08/2005 P/N 255105 (Rev.5) 08/2005 PAGE 2 OHIO MEDICAL CORPORATION PAGE 3 1.0 User Responsibilities The

More information

Series VM. Mechanical Valves VM200. VM1000 Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25

Series VM. Mechanical Valves VM200. VM1000 Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25 Mechanical Valves Series VM Model Dimensions (mm) VM1000 Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25 VM100 Side ported 17 x 44 x 25 Bottom ported 17 x 44 x 30 VM200 25 x 40 x 52 One way roller

More information

Fittings, Tubing & Nipples

Fittings, Tubing & Nipples s, Tubing & Nipples P Series Pipe s s to 15,000 psi (1034 bar) Since 1945 Parker utoclave Engineers has designed and built premium quality valves, fittings and tubing. This commitment to engineering and

More information

Medical Air Systems: Scroll

Medical Air Systems: Scroll GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing

More information

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations VICKERS Pressure Relief Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 Sectional Illustrations RCG-** Model Shown RCT-** Model Shown Basic Characteristics Type...................

More information

Shut-off & Lockout Valves 1/4" to 1-1/2" port size

Shut-off & Lockout Valves 1/4 to 1-1/2 port size Section 16 Shut-off & Lockout Valves 1/4" to 1-1/2" port size Contents T72 Excelon Shut-off & Lockout Valves 1/4", 3/8" Port Sizes....................................ALE-16-2 T73 Excelon Shut-Off & Lockout

More information

New. absolute filter elements independently tested in the following Institutes: MPH-MPI 02050/7.99/USA 2 COVER INSERT

New. absolute filter elements independently tested in the following Institutes: MPH-MPI 02050/7.99/USA 2 COVER INSERT e s c r i p t i o n MPH and MPI series filters are designed for returnline applications and provide various installation applications. The filters are installed semiimmersed or totally immersed into a

More information

Round Housing with Side Ports

Round Housing with Side Ports Power Steering Steering Control Unit (SCU) Parts and Repair Information 5 Series Steering Control Units 001 Square Housing with Side Ports Round Housing with Side Ports T E L RP Round Housing with End

More information

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric

More information

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR

More information

SWIMMING POOL HEAT PUMP Owners Manual

SWIMMING POOL HEAT PUMP Owners Manual SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor

More information

Filters Air Dryers 08

Filters Air Dryers 08 Filters Air Dryers 08 PuraGuard Filter For service new replacement assembly use PuraGuard QC Filter Service 801731 Maintenance Kit 5006788 Rebuild Kit 5006789 Included In Kit 5006788 Included In Kit 5006789

More information

Kompressoren. Adsorption Dryer AD

Kompressoren. Adsorption Dryer AD Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

Pressure reducing valve, direct operated, Type ZDR 6 D

Pressure reducing valve, direct operated, Type ZDR 6 D RE 26 57/2.3 Replaces:.2 Pressure reducing valve, direct operated, ype ZDR 6 D Nominal size 6 Series 4X aximum operating pressure 2 bar aximum flow 5 L/min K 4279/ ype ZDR 6 DP2 4X/ Y Overview of contents

More information

Directory chapter 04

Directory chapter 04 M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................

More information

introduction to constant level lubrication

introduction to constant level lubrication introduction to constant level lubrication Constant level oilers are designed to maintain a predetermined oil level in a sump, which is necessary for proper lubrication. If the oil level were to drop below

More information

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The

More information

MHT. Pressure Filters HIGH PRESSURE INLINE FILTER

MHT. Pressure Filters HIGH PRESSURE INLINE FILTER MHT Pressure Filters HIGH PEUE INLINE FILTE Pressure Filters MHT MHT 4 MPa ( bar) Port sizes: / / Flow rates: 0 l/min TEHNIAL DATA Max. working pressure: 4 MPa ( bar) Max. testing pressure: 6 MPa (60 bar)

More information

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51 83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE

More information

Description. Rc NPT G 1/8 1/4 3/8 1/2 3/4. With drain cock Drain guide 1/8 Drain guide 1/4 Drain cock with barb fitting: For ø6 x ø4 nylon tube

Description. Rc NPT G 1/8 1/4 3/8 1/2 3/4. With drain cock Drain guide 1/8 Drain guide 1/4 Drain cock with barb fitting: For ø6 x ø4 nylon tube M Mist Sparator to M Micro Mist Sparator to Sris M ominal filtration rating: 0.3 µm Sris ominal filtration rating: µm How to Ordr Mist Sparator Micro Mist Sparator, M, Option/Smi-standard: Slct on ach

More information

Float and Thermostatic Traps Series H, C and X

Float and Thermostatic Traps Series H, C and X Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 2 A S E R I E S Catalogue 2005-2006 Directly operated solenoid valves Series A 2/2 way, 3/2 way monostable, bistable (with magnetic memory) Ports M5,, cartridge ø4 The Series A solenoid valves are of the

More information

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide HG600/HG800 Hydro-Power Unit Installation and Operation Guide Copyright 04 HydroSpin, All rights reserved. The data contained in this document is proprietary to HydroSpin. It is disclosed to the receiving

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing) CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.

More information

PRODUCT MANUAL - M090

PRODUCT MANUAL - M090 PRODUCT MANUAL - M090 MODEL 203/266 ELECTRIC CAN OPENER 1 SAFETY CAUTION: SEVERED CAN LIDS HAVE CUTTING EDGES. USE OF A PROTECTIVE GLOVE OR TONGS IS ADVISED WHEN HANDLING LIDS. WARNING To avoid risk of

More information

NORMAN FILTER COMPANY PRODUCT OVERVIEW

NORMAN FILTER COMPANY PRODUCT OVERVIEW NORMAN FILTER COMPANY PRODUCT OVERVIEW LEADING THE WAY IN QUALITY FILTRATION WWW.NORMANFILTERS.COM FILTER ELEMENT INTERCHANGE Tee-Type Filter 4500, 14500, 34500, and 54500 Series Mini Tee-Type Filter 4100

More information

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description Worldwide Contacts www.tyco-fire.com Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and they are designed

More information

Cooling system components, removing and installing

Cooling system components, removing and installing Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate

More information

Adsorption air dryers ADS 1 215

Adsorption air dryers ADS 1 215 Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that

More information