Model: RXT. Model RXT Automatic Transfer Switch. Standard Features. Standard Interface Board. Available Models
|
|
|
- Harold Jackson
- 9 years ago
- Views:
Transcription
1 Model: RXT Automatic Transfer Switch Amps Covers have been removed for illustration. Available Models D 100,, and amp standard and service entrance models are available. D 150 and 300 amp service entrance models are also available. D Combined interface/ load management board is available on single-phase standard and service entrance models. (Not available on 3-phase or load center models.) D 100 amp standard single-phase models are available with or without a 16-space load center. Up to 8 tandem breakers can be used for a total of 24 circuits. D 100amp standard single phase model with a 12-space load center and a NEMA 1 enclosure is available as a standalone non-configurable spec (GM85273-SA_). D See page 7 for more information. Model RXT Automatic Transfer Switch The Model RXT automatic transfer switch is designed for use only with Kohlerr generator sets equipped with RDC2 or DC2 generator set/transfer switch controls. The transfer switch operation is controlled by the RDC2/DC2 controller. Standard Features D Allows utility voltage display on the RDC2/DC2 generator set/transfer switch controller, available exclusively on Kohlerr residential and light commercial generator sets D UL listed d Models with load centers, UL 67 listed, file # E d Models without load centers, UL 1008 listed, file # E58962 D CSA certification, file # LR58301, is available for: d Standard ATS without load center (single and three-phase) d Service entrance ATS 100 and amp models D Corrosion-resistant NEMA 3R aluminum enclosure d Padlockable d Approved for indoor or outdoor installation d ANSI 49 gray D NEMA 1 enclosure available on 100 amp load center models D Contactor electrically and mechanically interlocked D Double throw inherently interlocked design D Contactor manually operable for maintenance purposes D Silver alloy main contacts D Transfer switches are 100% equipment rated and can be applied at the rated current without derating (non-service entrance models) D Service entrance models include disconnect circuit breaker on the utility (normal) source side (80% rated) D Five-year limited warranty Standard Interface Board D Standard interface board connects to the Model RDC2 or DC2 generator set/transfer switch controller. D Includes a load control contact that provides a 5 minute time delay for startup of selected loads after transfer to the emergency source. Use for large motor loads. Combined Interface/ Load Management Board D Optional combined interface/ load management board replaces the standard interface board and connects to the Model RDC2 or DC2 generator set/transfer switch controller. D The combined board is available on single-phase standard and service entrance models. (Not available on 3-phase or load center models.) D The combined board automatically manages up to six residential loads: d Up to four customer-supplied power relay modules can be connected for management of non-essential secondary loads. d Two HVAC relays are included for control of two independent air conditioner loads. G (Model RXT Automatic Transfer Switch) 4/16d Page 1
2 Controller interface connections A and B Controller interface connections PWR and COM Load control contact rating Load control connections Specifications Standard Interface Board #20 AWG shielded twisted-pair Belden 9402 or 8762 or equivalent # AWG (see ATS Installation Manual) VAC # AWG Note: For combined interface/load management board specifications, see page 3. Environmental Specifications Operating temperature 20_Cto70_C ( 4_F to 158_F) Storage temperature 40_Cto85_C ( 40_F to 185_F) Humidity 5 to 95% noncondensing Codes and Standards The ATS meets or exceeds the requirements of the following specifications: D Underwriters Laboratories UL 67, Enclosed Panel Boards (load center models) file # E D Underwriters Laboratories UL 1008, Standard for Automatic Transfer Switches for Use in Emergency Systems, file #E58962 D Underwriters Laboratories UL 508, Standard for Industrial Control Equipment D CSA certification available, file # LR58301 (not available for 150, 300, or amp service entrance or 100 amp load center models). Must be selected when the transfer switch is ordered. D NFPA 70, National Electrical Code D NFPA 110, Emergency and Standby Power Systems D NEMA Standard IC , AC Automatic Transfer Switches Cable Sizes AL/CU UL-Listed Solderless Screw-Type Terminals for External Power Connections Switch Range of Wire Sizes, Cu/Al Size, Amps Switch Phases Normal and Emergency Load Neutral Ground Standard 1 (1) # /0 AWG (1)#14 1/0AWG (3) #12 to 250 KCMIL (Cu) or (3) #10 to 250 KCMIL (Al) 12-space (9)#4 14AWG per customer-supplied (13) # AWG or load center 1 (1)#14 1/0AWG circuit breaker (1)#6 2/0AWG (NEMA 1) space load center (NEMA 3R) Service Entrance 1 (1)#14 1/0AWG 1 Normal: (1) #12 2/0 AWG Emerg: (1) #14 1/0 AWG per customer-supplied circuit breaker (1)#14 1/0AWG 3-Phase 3 (1)#14 1/0AWG (1)#14 1/0AWG Service Entrance 1 Normal: (1) #4 300 KCMIL Emerg: (1) # KCMIL (1) #6 250 KCMIL Standard 1 (1)#6AWG 250KCMIL (1) #6 250 KCMIL 3-Phase 3 (1)#6AWG 250KCMIL (1) #6 250 KCMIL Service Entrance 1 Standard 1 3-pole V 3 3 or 4 pole 480 V 3 Normal: : (1) # KCMIL or (2) #1 250 KCMIL Emerg: (2) # KCMIL (2) #6 250 KCMIL (2) #6 250 KCMIL (2) #6 250 KCMIL (1) #4 600 KCMIL (2) 1/0 250 KCMIL (1) #4 600 KCMIL (2) 1/0 250 KCMIL (27) # AWG or (3) #4 -- 1/0 AWG or (1)#6 2/0AWG (3) #12 to 250 KCMIL (Cu) or (3) #10 to 250 KCMIL (Al) (3)#4AWG 600KCMIL (6) 1/0 250 KCMIL (3) #12 to 250 KCMIL (Cu) or (3) #10 to 250 KCMIL (Al) (3) #12 to 250 KCMIL (Cu) or (3) #10 to 250 KCMIL (Al) (3)#4AWG 600KCMIL (6) 1/0 250 KCMIL (3) #4 600 KCMIL (6) 1/0 250 KCMIL (3) #4 600 KCMIL (6) 1/0 250 KCMIL (9)#4 14AWG (3)#14 1/0AWG (3)#6 3/0AWG (3)#14 1/0AWG (9)#4 14AWG (3)#6 3/0AWG (3)#6 3/0AWG (3)#6 3/0AWG Note: Data is subject to change. Refer to the transfer switch dimension drawings and wiring diagrams for planning and installation. G (Model RXT Automatic Transfer Switch) 4/16d Page 2
3 Optional Combined Interface/Load Management Board The RXT transfer switch is available with either a standard interface board or a combined interface/ load management board. The combined board allows load management as described below. Load Management D The combined load management board disconnects non-critical loads to prevent generator overload, in compliance with NEC. D The combined load management board monitors generator current and frequency to determine when to add or shed loads. This monitoring prevents frequency drops that can damage valuable electronics like computers and televisions. D Load management allows the use of a smaller generator set. Operation D Loads are automatically added or shed based on generator capacity. D The load control system uses dynamic logic to prevent shedding important loads unnecessarily when air conditioning, refrigerator, or water pump motors start (patent pending). D The load management board and generator communicate to provide smart power management. The time to shed loads decreases as each load is shed to quickly adapt to critical power requirements. D Load shed power level and frequency setpoints can be adjusted using a personal computer (laptop) and Kohlerr SiteTecht software, which is only available to Kohlerauthorized distributors and dealers. Priority Setting D Loads are added and shed according to their priority. Load 1 is the top priority, which is added first and shed last. Load 6 is the lowest priority. D Less critical loads can be turned off automatically when essential appliances are running. D Load priorities are hard-wired at installation. Viewing Load Shed Outputs with OnCuer Plus D Use Kohler s OnCuer Plus Generator Management System (sold separately) to view load status (On or Off) for loads connected to the load shed relays. D Use OnCuer Plus to remotely monitor when loads are shed or added. D The load shed outputs can be labeled in OnCuer Plus. Current Transformer D The combined load management board option includes a amp current transfomer (CT) for load monitoring. D A larger diameter CT is available for applications that require larger cables. D A 500 amp CT is available for use with a 60RCL generator. D See the table below for current transformer specifications and optional kit numbers. Load Shed Specifications Connection Rating Connection Pilot Relays* 125VAC, 10 A total (general purpose) 120VAC, 125VA (pilot duty) # AWG HVAC Relays (qty. 2) 125VAC, 10 A (general purpose) 120VAC, 125VA (pilot duty) # AWG RBUS Communication and Power Connections to the RDC2/DC2 controller VDC Use Belden #9402 or equivalent 20 AWG shielded, twisted-pair communications cable [ * Four (4) pilot relays are provided for customer-supplied normally closed load-switching contactors/relays. The combination of four load relay outputs cannot exceed 10 amps total current draw. Kohlerr power relay modules are recommended. [ For long distances, use an equivalent shielded, twisted-pair cable for RBUS connections and individual AWG wires (qty. 2) for power connections. Current Transformer Specifications Ratio (Amps:VAC) Outer Diameter mm (in.) Inner Diameter mm (in.) : (2.5) 28.7 (1.13) GM83929 N/A Service Part Number Sales Kit Part Number CT Availability Included with combined board : (4.4) 57.2 (2.25) GM17250 GM17250-KP1-QS Sold Separately 500: (6.75) (4.25) GM60264 GM17250-KP2-QS Sold Separately (use with 60RCL) G (Model RXT Automatic Transfer Switch) 4/16d Page 3
4 Withstand and Close-On Ratings (WCR) Service Entrance Transfer Switch Ratings The service entrance transfer switch is factory-equipped with a normal source disconnect circuit breaker. Suitable for the control of motors, electric discharge lamps, tungsten filament lamps and electric heating equipment where the sum of motor full-load ampere ratings and the ampere ratings of other loads do not exceed the ampere rating of the switch and the tungsten load does not exceed 30 percent of switch rating. Switch Rating, Amps * WCR, RMS Symmetrical Amps at 240 VAC 100, 150, 22, , 35,000 * Continuous load current not to exceed 80% of switch rating. Contactor Ratings with Coordinated Circuit Breakers Single-phase transfer switches are UL listed at 240 VAC maximum. Three-phase transfer switches are rated at 480 VAC maximum. The following table lists contactor withstand current ratings (WCR) for ampere non-service entrance rated switches with specific manufacturer s circuit breakers per UL and Canadian safety standards. Suitable for the control of motors, electric discharge lamps, tungsten filament lamps and electric heating equipment where the sum of motor full-load ampere ratings and the ampere ratings of other loads do not exceed the ampere rating of the switch and the tungsten load does not exceed 30 percent of switch rating. The transfer switch is rated for use on a circuit capable of delivering not more than the RMS symmetrical amperes maximum as shown in the tables below, but no greater than the interrupting capacity of the selected breaker. Switch Rating, Amps Voltage, max WCR Ratings with Specific Manufacturer s Molded-Case Circuit Breakers Number of Poles/ Phases 2 pole/ 1 phase 2 pole/ 1 phase 3 pole/ 4 pole/ WCR, RMS Symmetrical Amps Manufacturer Type or Class Maximum Size, Amps 10,000 Any Breaker Any Breaker (0.025 seconds max.) FB, FCL 100 Eaton QCHW ,000 FDC 150 ITE/Siemens CED6, ED4, ED6, HED4, HED6 125 Square D FI ,000 Any Breaker Any Breaker (0.025 seconds max.) 30,000 Eaton ITE/Siemens General Electric Schneider FCL 100 JGS, JGH, JGC, JGU, JGX, JBD, JD, HJD, JDC, 250 LCL, LCLA LDC, CLDC, KDB, KD, HKD, KDC, LD, CLD, HLD, CHLD CED6, HED4, HED6 125 CFD6, FD6A, FXD6, HFD6, HFXD6, HHFD6, 250 HHFXD6 CJD6 SEL, SEP, THLC1 150 THLC2 225 SFH, SFL, SFP 250 SGH, SGL, SGP, FGN, FGH, FGL, FGP HG, HJ, HL, HR 150 JJ, JL, JR 250 LG, LJ, LL, LR G (Model RXT Automatic Transfer Switch) 4/16d Page 4
5 Switch Rating, Amps 300 Voltage, max WCR Ratings with Specific Manufacturer s Molded-Case Circuit Breakers Number of Poles/ Phases 2 pole/ 1 phase 35,000 3 pole/ 3 pole/ 4 pole/ WCR, RMS Symmetrical Amps Manufacturer Type or Class Maximum Size, Amps ABB T5, T6 600 CHKD, CKD, DK, HKD, KD, KDB, KDC, LA TRIPAC, LCL Eaton CHLD, CLD, CLDC, HLD, LD, LDB, LDC 600 HMDL, MDL, NB TRI--PAC 800 General Electric FGH, FGL, FGN, FGP, SGHA 600 CJD6, HHJD6, HHJXD6, HJD6, HJGA, HJXD6, JD6, JXD2, JXD6, SCJD6, SHJD6, SJD6 Siemens CLD, HHLD, HHLXD, HLD, HLGA, HLXD, LD, LLGA, LXD, NLGA, SCLD, SHLD, SLD CMD, HLMD, HLMXD, HMD, HMG, HMXD, LMD, LMG, LMXD, MD, MXD, NMG, SCMD, SHMD, SMD Square D LA, LC, LE, LH, LI, LX, LXI DG,DJ,DL,LC,LE,LI,LX,LXI 600 Merlin Gerin CJH, CJL, CJN CJ600H, CJ600N ,000 Any Breaker Any Breaker (0.017 seconds max.) ,000 Eaton LD ,000 HJD, JDC, JGC, JGH, JGU, JGX 250 CHLD4, CLD, HLD4, CLDC, LDC, KDC, HKD, CHMDL4, CMDL4 Eaton CHLD6, HDL6, CHMDL6, CMDL6, CLDC, CLD6, 600 LDC6, CLDC6 CHMDL8, HMDL8, MDL8, CMDL8 800 ITE/Siemens CFD6, HFD6, HFXD6, HHFD6, HHFXD6 250 General Electric SFL, SFP 250 FGL, FGP 600 Schneider LJ, LL, LR G (Model RXT Automatic Transfer Switch) 4/16d Page 5
6 Dimensions and Weights Note: Always use the transfer switch dimension drawing for planning and installation. Weights and dimensions may vary for different configurations. See the Operation/Installation Manual or your local distributor for dimension drawings. Transfer switch weights and dimensions shown in the table do not include packaging. To estimate the shipping weight, add 3 kg (5 lbs.) or 10% (whichever is larger) to the weight shown. H W D* Shipping Weight ] Dimension Amps Description Dimensions, H x W x D, mm (in.) [ kg (lb.) Drawing Single phase 623 x 335 x 180 (24.5 x 13.2 x 7.1) 7 (15) ADV-8688 With 12- or 16-space load center (NEMA 1) 610 x 330 x 154 (24.0 x 13.0 x 6.0) 12 (26) ADV With 16-space load center 614 x 335 x 180 (24.2 x 13.2 x 7.1) 8 (18) ADV-8690 Three phase 682 x 462 x 228 (26.8 x 18.2 x 9.0) 14 (30) ADV-8689 Service entrance (ASE) 731 x 416 x 175 (28.8 x 16.4 x 6.9) 12 (26) ADV-8687 Service entrance (CSE) 735 x 416 x 175 (28.9 x 16.4 x 6.9) 16 (34) ADV Service entrance (ASE) 734 x 416 x 175 (28.9 x 16.4 x 6.9) 12 (26) ADV-8687 Service entrance (ASE) 734 x 416 x 175 (28.9 x 16.4 x 6.9) 12 (26) ADV-8687 Service entrance (CSE) 735 x 416 x 175 (28.9 x 16.4 x 6.9) 14 (30) ADV-8666 Single phase 623 x 335 x 180 (24.5 x 13.2 x 7.1) 7 (15) ADV-8688 Three phase 682 x 462 x 228 (26.8 x 18.2 x 9.0) 14 (30) ADV Service entrance 1075 x 559 x 329 (42.3 x 22.0 x 12.9) 46 (101) ADV-8694 Single phase 1067 x 559 x 329 (42.0 x 22.0 x 12.9) 55 (120) ADV Pole/ volts 1067 x 559 x 329 (42.0 x 22.0 x 12.9) 41 (90) ADV Pole/480 volts 1222 x 610 x 343 (48.1 x 24.0 x 13.5) 59 (130) ADV Pole 1222 x 610 x 343 (48.1 x 24.0 x 13.5) 59 (130) ADV-8693 Service entrance 1075 x 559 x 329 (42.3 x 22.0 x 12.9) 46 (101) ADV-8694 [ Depth does not include the padlock hasp on the front of the enclosure. ] Transfer switch weights are approximate and do not include packaging. Note: Enclosures are type NEMA 3R except as noted. G (Model RXT Automatic Transfer Switch) 4/16d Page 6
7 - Power relay modules D 50 amp DPST power relay mounted in a NEMA type 3R enclosure D Use up to four modules with the combined interface/ load management board D UL/cUL listed D Dimensions: 172 x 233 x 92 mm (6.8 x 9.2 x 3.6 in.) D For more information, see specification sheet G Status indicator kit for standard interface board D LEDs indicate normal and emergency source availability and contactor position D Mounts on the outside of the RXT enclosure D View transfer switch status without removing enclosure cover D An overhang on the enclosure protects the indicator panel and ribbon cable opening D Dimensions: 92 mm x 42 mm (3.62 in. x 1.65 in.) D Connects to the standard interface board only D For more information on the status indicator kit, see specification sheet G Accessories - Status indicator kit for combined interface/ load management board D LEDs indicate normal and emergency source availability and contactor position D Dual color LEDs for each load indicate load status (powered or shed) and flash during a test D Load shed test button allows the operator to cycle the load shed relays in order of priority (when generator is in RUN mode) D Mounts on the outside of the RXT enclosure D View transfer switch and load status without removing enclosure cover D An overhang on the enclosure protects the indicator panel and ribbon cable opening D Dimensions: 183 mm x 42 mm (7.20 in. x 1.65 in.) D Connects to the combined interface/ load management board only D For more information on the status indicator kit, see specification sheet G Available Models All Model RXT transfer switches are standard-transition 60 Hz automatic transfer switches. Letters in parentheses refer to the model designation code described on the last page. Amps Description (Connections) 208 (C) Voltages 240 (F) 480 (M) Poles Phases WCR w RMS Symmetrical Amps Standard (A) D 2(N) 1 10,000 Standard, with 16-space load center (B) W D 2(N) 1 10, Standard, with 12-space load center ** D 2(N) 1 10,000 Service entrance (ASE, CSE) D 2(N) 1 22,000 Standard, 3-phase (A) D D D 3(T)or4(V) 3 30, Service entrance (ASE) D 2(N) 1 22,000 Standard (A) D 2(N) 1 10,000 Service entrance (ASE, CSE) D 2(N) 1 22,000 Standard, 3-phase (A) D D D 3(T)or4(V) 3 30, Service entrance (ASE) D 2(N) 1 35,000 Standard (A) D 2(N) 1 50,000 Service entrance (ASE) D 2(N) 1 35,000 Standard, 3-phase (A) D D D 3(T)or4(V) 3 50,000 w Withstand and close-on rating. See pages 3-5 for WCR information and specific breaker ratings. W With 16-space load center and NEMA 1 or NEMA 3R enclosure. Up to 8 tandem breakers can be used, for a maximum of 24 circuits. ** GM SA_ with 12-space load center and NEMA 1 enclosure. Note: Combined interface board is available on single-phase standard or service entrance models. (Notavailable on 3-phase orload centermodels.) G (Model RXT Automatic Transfer Switch) 4/16d Page 7
8 KOHLER CO., Kohler, Wisconsin USA Phone , Fax For the nearest sales and service outlet in the US and Canada, phone KOHLERPower.com Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore Phone (65) , Fax (65) Model Designation Model Controls Voltage Poles Enclosure Current Rating Connections Record the transfer switch model designation in the boxes. The transfer switch model designation defines ratings and characteristics as explained below. Sample Model Designation: RXT-JFNC-0A Model RXT: Kohler Automatic Transfer Switch Controls J: Interface for RDC2/DC2 Controller (standard or combined interface/ load management) Voltage/Frequency C: 208 Volts/60 Hz (3-phase only) F: 240 Volts/60 Hz M: 480 Volts/60 Hz (3-phase only) Number of Poles/Wires N: 2-pole, 3-wire, solid neutral (120/240 V only) T: 3-pole, 4-wire, solid neutral V: 4-pole, 4-wire, switched neutral Enclosure A: NEMA 1 * C: NEMA 3R * NEMA 1 enclosure is available on 100 amp load center models only. Current Rating 0100: 100 amps 0150: 150 amps 0: amps 0300: 300 amps 0: amps Connections A: No load center B: With load center (100 amp single-phase only) ASE: Service entrance rated CSE: Service entrance rated with CSA certification (100/ amps only) DISTRIBUTED BY: Availability is subject to change without notice. Kohler Co. reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohlerr generator distributor for availability. 2014, 2015 and 2016 by Kohler Co. All rights reserved. G (Model RXT Automatic Transfer Switch) 4/16d Page 8
RXT. Model: Model RXT Automatic Transfer Switch
Model: RXT Automatic Transfer Switch -- Model RXT Automatic Transfer Switch The Model RXT automatic transfer switch is designed for use only with Kohlerr generator sets equipped with RDC2 or DC2 generator
Model KSS. Transfer Switch Standard Features. Available Controllers. Ratings. Automatic Transfer Switches Standard Specific-Breaker Rated
Model KSS Automatic Transfer Switches Standard Specific-Breaker Rated Available Controllers D Decision-Makerr MPAC 750 D Decision-Makerr MPAC 1200 Transfer Switch Standard Features D UL 1008 listed at
Model KGS/KGP. Automatic Transfer Switches Bypass/Isolation. Transfer Switch Standard Features. Controller. Standard Transition Models (KGS) Ratings
Model KGS/KGP Automatic Transfer es Bypass/Isolation Controller D Decision-Makerr MPAC 1500 Ratings Model Current Voltage, Frequency Transfer Standard Features D UL 1008 listed at 480 VAC, file #E108981
Model: RDT. Automatic Transfer Switch 100-400 Amps. 200 amp load center models use up to 24 circuit breakers
Model: RDT Automatic Transfer Switch 100-400 Amps MPAC 500 Controller Features User-friendly interface with easy-to-read international symbols Source available and contactor position indicators LED indication
Controller Features. Modbus link to define inputs and outputs. Programmable Outputs Auxiliary switch fault Common fault.
Model KCT Automatic Transfer Switches Ratings Voltage: 208--600 VAC 50/60 Hz Current: 30--3000 amps Standard Contactor Features Open-transition operation with either automatic or non-automatic control
MPAC 1500 Controller
Model KSS/KSP Specific-Breaker Rated ATS Ratings Voltage: Current: 208--480 VAC 50/60 Hz 40--1000 Amps (standard transition) 100--600 Amps (programmed transition) Transfer Switch Standard Features UL 1008
Decision-Maker Paralleling System. Power Distribution Switchboards and Circuit Breakers. Standard Features
Decision-Maker Paralleling System Power Distribution Switchboards and Circuit Breakers Power Distribution Switchboards and Circuit Breakers The generator paralleling circuit breakers for the Kohler Decision-Maker
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
TS 910 AUTOMATIC TRANSFER SWITCHES OWNERS MANUAL
TS 910 AUTOMATIC TRANSFER SWITCHES OWNERS MANUAL INSTALLATION, OPERATING & SERVICE PM140 Rev 2 14/01/23 9087A 198 th Street, Langley, BC Canada V1M 3B1 Telephone (604) 888-0110 Telefax (604) 888-3381 E-Mail:
Continuous Power... Continuous Protection
Series 165 We Keep Your Power On Continuous Power... Continuous Protection An Automatic Transfer Switch helps prevent... Your business or home from losing power during bad weather or utility power equipment
Owner s Manual. For Automatic Transfer Switch. 100-200 Amp, Service Entrance/Non-Service Entrance
Owner s Manual For Automatic Transfer Switch 100-200 Amp, Service Entrance/Non-Service Entrance Model Numbers RTST100A3 RTSP100A3 RTST150A3 RTST200A3 RTSP200A3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:
O & M Manual for the 50-400A EGSX Transfer Switch
Contents Description Page 1. Introduction...2 2. Receiving, Handling, and Storage... 5 3. Equipment Description... 6 4. Installation and Wiring... 6 5. Functional Testing... 18 6. Maintenance and Component
Sentron Series Circuit Breakers
Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of
P4 Panelboards. Power Distribution Panelboards
P4 Panelboards Features The P4 panel is a medium sized footprint distribution panel to fit a large number of applications that require more or larger branch devices and higher amp ratings than the lighting
Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1
How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module
Automatic Transfer Switch Controller
Automatic Transfer Switch Controller Decision-Makerr MPAC 1500 Model KBS with Decision-Makerr MPAC 1500 Controller Applicable Models Model Description KCS Standard-Transition Any Breaker ATS ] KCP Programmed-Transition
ASCO SERIES 185 Power Transfer Switches
ASCO SERIES 185 Power Transfer Switches 4-hour protection no matter when trouble strikes ASCO Series 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... Your business or home from
Selection and application guide. Panelboards. usa.siemens.com/panelboards
Selection and application guide Panelboards usa.siemens.com/panelboards 1 SECTION Contents PAGE Introduction 2 General Specifications 3-5 Catalog Numbering System 6 A detailed Table of Contents is located
Solid State Timers Type F
Solid State Timers Type F Class 9050 CATALOG CONTENTS Description.....................................................Page Product Descriptions............................................. 3 Application
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
How To Operate A Gec Transfer Switch Open Transition 40 2000 Amp Power Supply
GTEC Transfer switch open transition 40 2000 amp Description GTEC transfer switches combine reliability and flexibility in a small, economical package for transferring loads between a utility and a generator
GTEC transfer switch open transition
GTEC transfer switch open transition 40-1250 Amp Description The GTEC automatic transfer switch combines reliability and flexibility in a small, economical package for transferring loads between a utility
PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers
Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Catalog 2004 Class 601 CONTENTS Description..............................................Page INTRODUCTION.............................................
Corner-Grounded Delta (Grounded B Phase) Systems
Data Bulletin 2700DB0202R03/12 09/2012 Replaces 2700DB0202R2/09 dated 02/2009 Corner-Grounded Delta (Grounded B Phase) Systems Class 2700 Retain for future use. Introduction Corner-grounded delta systems
T7079A,B Solid State Remote Temperature Controllers
T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature
Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations
Connecting the Power of the Sun DC Disconnects for Solar Photovoltaic Installations DC disconnects for solar photovoltaic installations Solar energy is heating up Interest in renewable energy sources has
Cisco Unified IP Phone Power Injector
Data Sheet Cisco Unified IP Phone Power Injector The Cisco Unified IP Phone Power Injector (Figure 1) increases the deployment flexibility of Cisco Unified IP phones by providing an alternative powering
Industrial Generator Set Accessories
Industrial Generator Set Accessories Snow Enclosure and Subbase Fuel Tank Package Applicable to the following: 80/100/150REOZJF 125REOZJG Enclosure with Standard Subbase Fuel Tank Enclosure with State
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
Distribution Dry Type Transformers
8 TRASFORMERS Distribution Dry Type Transformers Table (Contact Sales office for List Price) (commonly used) 1a. 115 C Rise F 1b. 80 C Rise B 4. Wall Brackets1 W 6. Low noise XdB below std. LX Type bg
Industrial Generator Set Accessories
Industrial Generator Set Accessories Weather/Sound Enclosure and Subbase Fuel Tank Package Applicable to the following: 40REOZJC 50/60REOZJD 80/100/150/200REOZJF 125/180REOZJG 230-275REOZJE 300REOZJ Enclosure
SECTION 26 29 23 VARIABLE FREQUENCY DRIVES
SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
DC disconnects for solar photovoltaic installations. Connecting the. power of the sun
DC disconnects for solar photovoltaic installations Connecting the power of the sun Solar energy is heating up Interest in renewable energy sources has never been greater, and the fastest growing of these
Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility
Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Catalog 2800CT1001R02/13 2013 Class 2800 CONTENTS Description............................................ Page 2 Indoor Charging
Fire Pump Controllers Remote Alarm Panels
Fire Pump Controllers Remote Alarm Panels Remote Alarm Panels 1.8 Remote Alarm Panels FDAP-M Electric... DFDAP-M Diesel... Product Specifications... 2 6 9 Features 1-1 DFDAP-M / FDAP-M Remote Alarm Panel
OUTPUT CABLE CONNECTIONS:
Tender Plus: Models: 12V1.25A and 6V1.25A The Tender Plus 12 Volt, 1.25 Amp 6 Volt, 1.25 Amp GENERAL DESCRIPTION: The Tender Plus battery charger is a desktop, portable, linear power converter that has
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)
9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity
Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide
Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management
INSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
EVlink Electric Car Charging Stations Powering the Future of Sustainable Mobility
EVlink Electric Car Charging Stations Powering the Future of Sustainable Mobility Catalog 2800CT1001 R09/15 2015 Class 2800 CONTENTS Description............................................ Page 2 Home
Owner's Manual. Automatic Transfer Switch. This manual should remain with the unit.
Owner's Manual Automatic Transfer Switch REFERENCE THE OWNER'S MANUAL SUPPLIED WITH THE GENERATOR WHEN USING THIS DOCUMENTATION. NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICATIONS. THIS PRODUCT
SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:
SWITCH The Budderfly lighting switch is a Decora style, plug-and-play replacement for your existing building switches. Installing a Budderfly adapter transforms your building s existing wiring into the
Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500
Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Description Firetrol FTA1500 Primary Resistance Fire Pump Controllers use resistors in the line to reduce line voltage
Manual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST
12VDC MAGNETIC ED DIMMABE POER SUPPIES SPEC SEET DIGEST TM-30-DIM TM-50-DIM T-60-DIM TM100-DIM TM200-DIM TM300-DIM iring Diagram for TM-50-DIM and TM-100-DIM ED 12VDC MAGNETIC DIMMABE 30 POER SUPPY Smallest
EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility
EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Catalog 2800CT1001 2014 Class 2800 CONTENTS Description............................................ Page 2 Outdoor
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog
APC DIN Rail Control Panel Mounting Uninterruptible Power Supply Catalog 2014 Contents Introduction, description... 4 Specifications...5 References....6 Dimensions...7 Wiring diagrams....8 Product reference
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Product overview The Tracer ZN517 controller is a field-installed, application-specific controller that provides directdigital
SPEEDFAX TM 2011 Disconnect Switches Contents
SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection
THERMAL MANAGEMENT SOLUTIONS
t2000 Series Electronic heat-tracing controller Product Overview /COMMUNICATIONS INTERACE CARRIER REQ TO SEND The DigiTrace heat trace controller is designed to provide the benefits associated with single
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to
O & M Manual for the 200A EGSU Automatic Transfer Switch with RTC-100 Control
Contents Description Page 1. Introduction............................ 2 2. Receiving, Handling, and Storage........... 5 3. Equipment Description................... 6 4. Installation and Wiring....................
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU5000RT4UHV Description Tripp Lite SU5000RT4UHV 5000VA / 5kVA /
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600
Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600 Data Bulletin 0600DB1104 03/2012 Retain for future use. Electronic Trip Circuit Breaker Basics 0600DB1104 Table of Contents
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SMART1000RM1U Description Tripp Lite SMART1000RM1U 1000VA / 1kVA / 800 watt line interactive,
AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A
AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components
Internet Office 750VA Ultra-compact Standby 120V UPS with USB port
Internet Office 750VA Ultra-compact Standby 120V UPS with USB port MODEL NUMBER: INTERNET750U Highlights 750VA ultra-compact 120V standby UPS Maintains AC output during power failures 6 UPS battery supported
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
Panelboards 11 PANELBOARDS. Type P2 Panelboards. General
General Features Flexibility is the hallmark of the P2 panel. This panel offers a wide array of factoryassembled options to meet almost all lighting panel applications. With this design, the ability to
Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811
Instruction Sheet 1-2003 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch. The
Catalog January. Heavy industrial power applications Motor contactors and starters
Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type
Secondary Unit Substations
14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically
PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets
PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets MODEL NUMBER: BC600SINE Highlights 600VA tower 120V standby UPS with SINE WAVE output Maintains AC output during power
Mini Power-Zone Unit Substation
Catalog 7440CT0901 2009 Class 7440 CONTENTS Description............................................. Page Product Description...........................................2 General Information...........................................3
Tmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL
SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated
OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port
OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port MODEL NUMBER: OMNIVS1500 Highlights 1500VA / 1.5kVA tower 120V line-interactive UPS Corrects brownouts and overvoltages from 75 to 147V
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire MODEL NUMBER: SU6000RT3UHV Highlights 6000VA / 6kVA / 4200W on-line double-conversion
PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual
PART 8: FIELD WIRING A. INSTALLATION MUST COMPLY WITH: 1. National Electrical Code and any other national, state, provincial or local codes or regulations. 2. In Canada, CSA C22.1 Canadian Electrical Code
D RDC2 Controller d One digital controller manages both the generator set and
Models: 14/20RESA Multi-Fuel / The Kohler r Advantage High Quality Power Kohler home generators provide advanced voltage and frequency regulation along with ultra-low levels of harmonic distortion for
Instructions & Safety Information Models A220-20D and A220-20L Version 2
Quick 220 Voltage Converting Power Supply Instructions & Safety Information Models A220-20D and A220-20L Version 2 Quick 220 Systems LLC PO Box 47489 Phoenix, Arizona 85068-7489 800-347-0394 602-938-6057
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS, Sine
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS,
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial MODEL NUMBER: SMART2200RM2U Highlights 2.2kVA / 2200VA / 1920W line interactive 2U
Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual
Freeze Protection Thermostats MODELS SST 2 Part Number 22744 MANUAL We Manage Heat Installation and Operation Manual Environmental Technology, Inc. 1850 N Sheridan Street South Bend, Indiana 46628 (574)
101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION. Cutler-Hammer
101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION Cutler-Hammer WELCOME Welcome to Module 3, Fundamentals of Electrical Distribution. If you have successfully completed Module
The Different Types of AC Power Connectors in North America
The Different Types of AC Power Connectors in North America White Paper 20 Revision 1 by James Spitaels > Executive summary A confusing array of AC power plugs and receptacles exist to deliver power to
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function
SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function Document No. 155-751 SKP15U.. Description Only when assembled to Series VGU Gas valves SKP15 electro-hydraulic actuators combine with
MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
Emerson Network Power Rack PDU Systems
AC Power For Business-Critical Continuity Emerson Network Power Rack PDU Systems Product Selection Guide - North American Models TABLE OF CONTENTS 1.0 EMERSON NETWORK POWER RACK PDU SYSTEMS..............................1
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial
SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMART500RT1U Description Tripp Lite's SMART500RT1U intelligent, line-interactive rack/tower uninterruptible
Industrial Generator Set Accessories
Industrial Generator Set Accessories Weather/Sound and Subbase Package Applicable to the following: 600-800REOZM 600-800REOZMB Weather Standard Features Critical silencer, flexible exhaust connector, and
Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.
Pump_PT580 Optional PT580-CFG PCM370 Optional DTM96 Buffered Dual Relay Remote Reset Local Display Condition Monitoring System PLC/DCS PT580 Digital Vibration Switch Introduction The PT580 Digital Vibration
Guidelines on the Short Circuit Current Rating for Industrial Control Panels
usa.siemens.com/sccr Guidelines on the Short Circuit Current Rating for Industrial Control Panels Technical Paper for Practical Applications White Paper I October 2014 As per NEC Edition 2014, and UL508A
SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION
SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION Please read and understand the product instruction manual before installing, servicing or operating Yaskawa products. Technical content
10000HXL31/15000HXL31/20000HXL31
Table of Contents www.eaton.com/dxups USER MANUAL ON LINE UPS 10000HXL31/15000HXL31/20000HXL31 Uninterruptible Power Supply Table of Contents 1. Brief introduction 1.1 System and model description---------------------------------------------------------------------1
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Transfer switch BTPC open, closed or delayed transition
Transfer switch BTPC open, closed or delayed transition 150-4000 Amp Description The Cummins Power Generation BTPC series bypass isolation transfer switch combines an automatic transfer switch with a drawout
Industrial Generator Set Accessories
Industrial Generator Set Accessories Aluminum and Steel and Subbase Fuel Tank Package All Generator Set,, and Fuel Tank Options are UL 2200 Certified. Available Approvals and Listings - UL 2200 Listing