1 Model KSS Automatic Transfer Switches Standard Specific-Breaker Rated Available Controllers D Decision-Makerr MPAC 750 D Decision-Makerr MPAC 1200 Transfer Switch Standard Features D UL 1008 listed at VAC file # E58962 (automatic), # E86894 (nonautomatic) D CSA certification available D IBC seismic certification available D Standard-transition operation D Silver tungsten alloy contacts on amp models D Solid or switched neutral D Available with either automatic or non-automatic control (non-automatic control requires the Decision-Makerr MPAC 1200 controller) D Available in 2, 3, or 4 pole configurations D High withstand/closing ratings, for use with specific breakers only D Electrically operated, mechanically held mechanism D Double-throw, mechanically interlocked design (break-before-make power contacts) D Enclosed arc chambers with arc chutes D Front-accessible contacts for easy inspection D Main shaft auxiliary position-indicating contacts (see page 3 for contact ratings) D Standard one-year limited warranty. Extended limited warranties are available. Ratings Model Current Voltage, Frequency KSS amps VAC, 50/60 Hz amps VAC, 50/60 Hz G (Model KSS Transfer Switch) 3/16a Page 1
2 Available Automatic Transfer Switch Controllers Select one of the following controllers for your automatic transfer switch. Decision-Makerr MPAC 750 Controller Decision-Makerr MPAC 1200 Controller D Test pushbutton D Exercise pushbutton D LED indicators: Source available, transfer switch position, service required (fault), and not in auto D Programmable voltage pickup and dropout settings D Programmable time delays D Seven day generator exerciser D Two programmable inputs and two programmable outputs D Modbus communication standard D RS-485 communication standard D Ethernet communication optional For more information about Decision-Makerr MPAC 750 features and functions, see specification sheet G D LCD display, 4 lines x 20 characters, backlit D Complete programming and viewing capability at the door using the keypad and LCD display D LED indicators: Source available, transfer switch position, service required (fault), and not in auto D Programmable voltage and frequency pickup and dropout settings D Programmable time delays D Programmable generator exerciser D Time-based load control D Two programmable inputs and two programmable outputs D Up to four I/O extension modules available D Modbus communication standard D RS-485 communication standard D Ethernet communication optional For more information about Decision-Makerr MPAC 1200 features and functions, see specification sheet G Codes and Standards The ATS meets or exceeds the requirements of the following specifications: D Underwriters Laboratories UL 1008, Standard for Automatic Transfer Switches for Use in Emergency Standby Systems file # E58962 (automatic), # E86894 (nonautomatic) D CSA C22.2 No. 178 certification available, file # LR58301 D NFPA 70, National Electrical Code D NFPA 99, Essential Electrical Systems for Health Care Facilities D NFPA 110, Emergency and Standby Power Systems D IEEE Standard 446, IEEE Recommended Practice for Emergency and Standby Power Systems for Commercial and Industrial Applications D NEMA Standard ICS , Electromechanical AC Transfer Switch Equipment D EN Fast Transient Immunity Severity Level 4 D IEC , Low Voltage Switchgear and Control Gear; Multifunction Equipment; Automatic Transfer Switching Equipment D EN Surge Immunity Class 4 (voltage sensing and programmable inputs only) D IEC Specifications for EMI/EMC Immunity: d CISPR 11, Radiated Emissions d IEC , Electrostatic Discharge d IEC , Radiated Electromagnetic Fields d IEC , Electrical Fast Transients (Bursts) d IEC , Surge Voltage d IEC , Conducted RF Disturbances d IEC , Magnetic Fields d IEC , Voltage Dips and Interruptions D IEEE 472 (ANSI C37.90A) Ring Wave Test D Seismic certification in accordance with the International Building Code is available. (Accessory kit is required for seismic certification.) d IBC 2000, referencing ASCE 7-98 and ICC AC-156 d IBC 2003, referencing ASCE 7-02 and ICC AC-156 d IBC 2006, referencing ASCE 7-05 and ICC AC-156 d IBC 2009, referencing ASCE 7-05 and ICC AC-156 d IBC 2012, referencing ASCE 7-10 and ICC AC-156 G (Model KSS Transfer Switch) 3/16a Page 2
3 Operating Temperature Storage Temperature Humidity Model KSS Environmental Specifications Switch Rating, C to70 C (--4 F to 158 F) C to85 C (--40 F to 185 F) 5% to 95% noncondensing Application Data UL-Listed Solderless Screw-Type Terminals for External Power Connections Range of Wire Sizes, Copper or Aluminum* Normal, Emergency, and Load Neutral Ground (1)#8to3/0AWG (3) #6 -- 3/0 AWG (1) #6 AWG to 250 KCMIL 260 (1) #6 AWG to 350 KCMIL 400 (1) #4 AWG to 600 KCMIL or (2) #6 AWG to 250 KCMIL (3) # KCMIL or (6) 1/ KCMIL 600 (2) #2 AWG to 600 KCMIL (6) # KCMIL 800 (2) #1/0 AWG to 750 KCMIL 1000 (4) #2 AWG to 600 KCMIL (12) # KCMIL * Use 60 C minimum wire for #14 to #1 AWG. Use 75 C minimum wire for 1/0 AWG and larger. (3) #6 -- 3/0 AWG (3) # KCMIL or (6) 1/ KCMIL Resistive Load Contact Ratings Inductive Load NC Motor Load Engine Start Contacts 2A@30VDC N/A N/A N/A Auxiliary Contacts, ( A) ] VAC N/A N/A N/A Auxiliary Contacts, ( A) ] VAC VAC; VAC ] Auxiliary position-indicating contacts, one set Normal and one set Emergency VAC; VAC; VAC NO VAC; VAC; VAC Weights and Dimensions Note: Always use the transfer switch dimension drawing for planning and installation. Weights and dimensions may vary for different configurations. See your local distributor for dimension drawings. Weights and dimensions are shown for transfer switches in NEMA type 1 and type 3R enclosures. Consult the factory for open units and other enclosures. NEMA Type Dimensions mm (in.) Weight kg (lb.) Height Width Depth w 2-Pole 3-Pole 4-Pole ADV Drawing , 3R 791 (31.1) 450 (17.7) 316 (12.5) 28 (62) 30 (65) 31 (68) ADV , 3R 1219 (48.0) 560 (22.0) 362 (14.3) 52 (115) 56 (123) 59 (131) ADV , 3R 1223 (48.1) 560 (22.0) 362 (14.3) 52 (115) 56 (123) 59 (131) ADV , 3R 1702 (67.0) 610 (24.0) 514 (20.2) 179 (395) 183 (403) 186 ( 410) ADV , 3R 1932 (76.1) 864 (34.0) 515 (20.3) N/A 226 (498) 236 (520) ADV , 3R 1932 (76.1) 864 (34.0) 515 (20.3) N/A 231 (509) 241 ( 531) ADV-8592 w Allow enough room to fully open the door for inspection and service per NEC and local codes. The NEMA type 3R enclosures have a security cover on the controller that extends 54 mm (2.1 in.) beyond the door. G (Model KSS Transfer Switch) 3/16a Page 3
4 Withstand and Close-On Ratings (WCR) Ratings Summary The transfer switch is rated for use on a circuit capable of delivering not more than the RMS symmetrical Amperes listed at the specified maximum voltage below, but no greater than the interrupting capacity of the selected circuit breaker or fuse. Circuit breakers and fuses are supplied by the customer. Certified Withstand Current Ratings in RMS Symmetrical Amperes W Specific Coordinated Breaker Rating, With Current-Limiting Fuses (see the following tables) Any Breaker Ratings ** Fuse Maximum Circuit Maximum Circuit Maximum Circuit Time Switch Size, Duration, Rating, Fuse Max Maximum Maximum Seconds Class 480 VAC 600 VAC Voltage 480 VAC 600 VAC Voltage 480 VAC 600 VAC Max J , , V 30,000 22, V 10,000 10, J ,000 N/A 600 V 30,000 22, V 10,000 10, N/A N/A N/A N/A 480 V 35,000 N/A N/A N/A N/A N/A J , , RK5 600 V 50,000 42, V 35,000 35, ,000 N/A RK1 600 N/A N/A N/A N/A 600 V 50,000 42,000 N/A N/A N/A N/A 800 L L ,000 N/A 480 V 65,000 N/A N/A N/A N/A N/A W All values are available symmetrical RMS Amperes and tested in accordance with the withstand/closing requirements of UL ** Applicable to breakers with instantaneous trip elements. Ratings with Specific Manufacturers Circuit Breakers Withstand and close-on ratings (WCR) in RMS symmetrical Amperes for specific manufacturers circuit breakers. Molded-Case Circuit Breakers Switch Rating, Voltage, Max , ,000 WCR, RMS Manufacturer Type Schneider Max. Size, FCL 100 JGS, JGH, JGC, JGU, JGX, JBD, JD, HJD, JDC, LCL, LCLA 250 LDC, CLDC, KDB, KD, HKD, KDC, LD, CLD, HLD, CHLD 400 CED6, HED4, HED6 125 CFD6, FD6A, FXD6, HFD6, HFXD6, HHFD6, HHFXD6 250 CJD6 400 SEL, SEP, THLC1 150 THLC2 225 SFH, SFL, SFP 250 SGH, SGL, SGP, FGN, FGH, FGL, FGP 400 HG, HJ, HL, HR 150 JJ, JL, JR 250 LG, LJ, LL, LR 400 JGS, JGH, JGC, JGU, JGX, JDB, JD, HJD, JDC, LCL, LCLA 250 LDC, CLDC, KDB, KD, HKD, KDC, LD, CLD, HLD, CHLD 400 CED6, HED4, HED6 125 CFD6, FD6, FXD6, HFD6, HFXD6, HHFD6, HHFXD6 250 SEL, SEP, THLC1 150 THLC2 225 SFH, SFL, SFP 250 SGH, SGL, SGP, FGN, FGH, FGL, FGP 400 G (Model KSS Transfer Switch) 3/16a Page 4
5 Molded-Case Circuit Breakers Switch Rating, Voltage, Max. WCR, RMS , , ,000 Manufacturer Type Max. Size, JGS, JGH, JGC, JGU, JGX, JDB, JD, HJD, JDC, LCL, LCLA 250 LDC, CLDC, LD, CLD, HLD, CHLD, KDB, KD, HKD, KDC 400 CED6, HED4, HHED6 125 CFD6, FD6, FXD6, HFD6, HFXD6, HHFD6, HHFXD6 250 SEL, SEP, THLC1 150 THLC2 225 SFH, SFL, SFP 250 SGH 350 SGH, SGL, SGP, FGN, FGH, FGL, FGP 400 HG, HJ, HL, HR 150 Schneider JJ, JL, JR 250 LG, LJ, LL, LR 400 HJD, JDC, JGC, JGH, JGU, JGX 250 CHLD4, CLD, HLD4, CLDC, LDC, KDC, HKD, CHMDL4, CMDL4 400 CHLD6, HDL6, CHMDL6, CMDL6, CLDC, CLD6, LDC6, CLDC6 600 CHMDL8, HMDL8, MDL8, CMDL8 800 CFD6, HFD6, HFXD6, HHFD6, HHFXD6 250 SFL, SFP 250 FGL, FGP 600 Schneider LJ, LL, LR 600 JGU, JGX 250 CLDC4, KDC, LDC4 400 CLDC6, LDC6, NB Tri-Pac 600 NB Tri-Pac 800 CFD6 250 CJD6, SCLD6 400 CLD6, HHLD6, HHLXD6, SCLD6 600 CMD6, HMD6, HMXD6,SCMD6, SHMD6 800 THLC1 150 FGL4, FGP4, THLC4, TLB4 400 SGL, SGP, FGL6, FGP6 600 SKL8, SKP8 800 Schneider JL, JR 250 G (Model KSS Transfer Switch) 3/16a Page 5
6 Switch Rating, Voltage, Max. WCR, RMS , ,000 65, Molded-Case Circuit Breakers Manufacturer Type Max. Size, HJD, JDC, JGC, JGH, JGU, JGX 250 CHLD4, CLD, HLD4, CLDC, LDC, KDC, HKD, CHMDL4, CMDL4 400 CHLD6, HLD6, CHMDL6, CMDL6, CLDC6, LDC6, CLD6, CLDC 600 CHMDL8, HMDL8, MDL8, CMDL8 800 CFD6, HFD6, HFXD6, HHFD6, HHFXD6 250 SFL, SFP 250 FGL, FGP 600 Schneider LJ, LL, LR 600 JGU, JGX 250 CLDC4, KDC, LDC4 400 CLDC6, LDC6, NB Tri-Pac 600 NB Tri-Pac 800 CFD6 250 CJD6, SCLD6 400 CLD6, HHLD6, HHLXD6, SCLD6 600 CMD6, HMD6, HMXD6, SCMD6, SHMD6 800 THLC1 150 FGL4, FGP4, THLC4, TLB4 400 SGL, SGP, FGL6, FGP6 600 SKL8, SKP8 800 Schneider JL, JR 250 TRI-PAC NB, CHMDL, HMDL, CHND, HND, NDC, CNDC 800 / Cutler-Hammer TRI-PAC NB, CNDC, NDC, CRDC, TRI-PAC PB, RDC, CHND, HND, 1200 RD. CRD Schneider/ Square D MJ,PJ,PL,RJ 800 PJ, PL, RL 1000 CMD6, HMD6, SCMD6, SHMD6, CND6, HND6, SCND6, SHND6, CPD6 800 CND6, HND6, SCND6, CPD6, SHND6, HPD TB8, TC, THC, THP 1000 THC, THP, TRP 1200 G (Model KSS Transfer Switch) 3/16a Page 6
7 Transfer Switch Accessories Accessories are available either factory-installed or as loose kits, unless otherwise noted. - CSA Certification - Digital Meter (with MPAC 1200 only) D Measure and display voltage, current, frequency, and power for both sources D Programmable visual alarms for high voltage, low voltage, and high current D Three digital outputs D Serial port for optional network connections D Password-protected programming menus D Joystick operation D Factory-installed D Three digital outputs D Joystick operation - Extended Limited Warranties D 2-year basic D 5-year basic D 5-year comprehensive D 10-year major components - Export Packaging - Heater, Anti-Condensation D Hygrostat-controlled 120 VAC strip heater (customer-supplied voltage source required) D 100 or 250 watts (sized for enclosure) D Protective 15 amp circuit breaker - Literature Kits D Production literature kit (one kit is included with each transfer switch) D Overhaul literature kit - Neutral Assembly D Available as loose kit for open units - RSA III Remote Serial Annunciator D Monitors the generator set D Monitors Normal and Emergency source status and connection D Monitors ATS common alarm D Allows remote testing of the ATS For more information, see specification sheet G Seismic Certification D Certification depends on application and geographic location. Contact your distributor for details. D Available for amp KSS models with NEMA 1, 3R, 4, 4X, and 12 enclosures - Surge Protection Device (SPD) D Surge protection reduces transient voltages to harmless levels D Protection modes: L-L / L-N / L-G / N-G D Replaceable phase and neutral cartridges for service D Frequency: Hz D Operating Temperature Range: --40 to 176_F (--40to80_C) D Remote contacts for customer-supplied status indicators: Contacts: 1 NO, 1 NC Min Load: 12VDC / 10 ma Max. Load: 250 VAC / 1 A Wire Size (max.): 16AWG D Fuse protection: 30 amps / 600 V D UL 1449, 3rd Edition for Type 2 applications D IEC , 2nd Edition T2/11 D See additional specifications below Additional Controller Accessories See the controller spec sheet for more information. - Accessory Modules (with MPAC 1200 only) D Alarm Module D External Battery Supply Module D Input/Output Module D High-Power Input/Output Module - Controller Disconnect Switch - Ethernet Communications - Current Sensing Kit (with MPAC 1200 only) - Line-to-Neutral Voltage Monitoring (with MPAC 1200 only) - Padlockable User Interface Cover - Supervised Transfer Control Switch (with MPAC 1200 only) Nominal Voltage (V ±15%) Max. Discharge Current (ka) Phase Poles UL VPR 3rd Ed (L-N/N-G/L-G) (kv) SPD Specifications Limiting Voltage, (L-N/N-G/L-G) (kv) Short Circuit Withstand Current (ka) Maximum Continuous Operating Voltage (VAC) at 3kA at 10kA 240 / Split / 1.2 / / 0.4 / / 0.7 / / / Wye / 1.2 / / 0.4 / / 0.7 / / / Wye / 1.2 / / 0.4 / / 0.7 / / / HLD / 1.2 / / 0.4 / / 0.7 / / / Wye / 1.2 / / 0.4 / / 0.7 / / 880 G (Model KSS Transfer Switch) 3/16a Page 7
8 KOHLER CO., Kohler, Wisconsin USA Phone , Fax For the nearest sales and service outlet in the US and Canada, phone KOHLERPower.com Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore Phone (65) , Fax (65) Model Designation Model Mechanism Transition Controls Voltage Poles Enclosure Current Rating Miscellaneous Record the transfer switch model designation in the boxes. The transfer switch model designation defines characteristics and ratings as explained below. Sample Model Designation: KSS-JCNA-0100S Model K: Kohler Mechanism S: Standard (Specific-Breaker) Transition S: Standard Controller A: Decision-Makerr MPAC 1200, Automatic B: Decision-Makerr MPAC 1200, Non-Automatic J: Decision-Makerr MPAC 750, Automatic Voltage/Frequency C: 208 Volts/60 Hz K: 440 Volts/60 Hz D: 220 Volts/50 Hz M: 480 Volts/60 Hz F: 240 Volts/60 Hz N: 600 Volts/60 Hz G: 380 Volts/50 Hz P: 380 Volts/60 Hz H: 400 Volts/50 Hz R: 220 Volts/60 Hz J: 416 Volts/50 Hz Number of Poles/Wires N: 2 Poles/3 Wires, Solid Neutral T: 3 Poles/4 Wires, Solid Neutral V: 4 Poles/ 4 Wires, Switched Neutral Enclosure A: NEMA 1 D: NEMA 4 B: NEMA 12 F: NEMA 4X C: NEMA 3R G: Open Unit Current, Connections S: Standard Note: Some selections are not available for every model. Contact your Kohler distributor for availability. DISTRIBUTED BY: Availability is subject to change without notice. Kohler Co. reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohlerr Power Systems distributor for availability. 2014, 2016 by Kohler Co. All rights reserved. G (Model KSS Transfer Switch) 3/16a Page 8
Model KGS/KGP. Automatic Transfer Switches Bypass/Isolation. Transfer Switch Standard Features. Controller. Standard Transition Models (KGS) Ratings
Model KGS/KGP Automatic Transfer es Bypass/Isolation Controller D Decision-Makerr MPAC 1500 Ratings Model Current Voltage, Frequency Transfer Standard Features D UL 1008 listed at 480 VAC, file #E108981
Model: RXT. Model RXT Automatic Transfer Switch. Standard Features. Standard Interface Board. Available Models
Model: RXT Automatic Transfer Switch 100 - Amps Covers have been removed for illustration. Available Models D 100,, and amp standard and service entrance models are available. D 150 and 300 amp service
Controller Features. Modbus link to define inputs and outputs. Programmable Outputs Auxiliary switch fault Common fault.
Model KCT Automatic Transfer Switches Ratings Voltage: 208--600 VAC 50/60 Hz Current: 30--3000 amps Standard Contactor Features Open-transition operation with either automatic or non-automatic control
MPAC 1500 Controller
Model KSS/KSP Specific-Breaker Rated ATS Ratings Voltage: Current: 208--480 VAC 50/60 Hz 40--1000 Amps (standard transition) 100--600 Amps (programmed transition) Transfer Switch Standard Features UL 1008
Model: RDT. Automatic Transfer Switch 100-400 Amps. 200 amp load center models use up to 24 circuit breakers
Model: RDT Automatic Transfer Switch 100-400 Amps MPAC 500 Controller Features User-friendly interface with easy-to-read international symbols Source available and contactor position indicators LED indication
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
RXT. Model: Model RXT Automatic Transfer Switch
Model: RXT Automatic Transfer Switch -- Model RXT Automatic Transfer Switch The Model RXT automatic transfer switch is designed for use only with Kohlerr generator sets equipped with RDC2 or DC2 generator
Automatic Transfer Switch Controller
Automatic Transfer Switch Controller Decision-Makerr MPAC 1500 Model KBS with Decision-Makerr MPAC 1500 Controller Applicable Models Model Description KCS Standard-Transition Any Breaker ATS ] KCP Programmed-Transition
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches
Decision-Maker Paralleling System. Power Distribution Switchboards and Circuit Breakers. Standard Features
Decision-Maker Paralleling System Power Distribution Switchboards and Circuit Breakers Power Distribution Switchboards and Circuit Breakers The generator paralleling circuit breakers for the Kohler Decision-Maker
GTEC transfer switch open transition
GTEC transfer switch open transition 40-1250 Amp Description The GTEC automatic transfer switch combines reliability and flexibility in a small, economical package for transferring loads between a utility
Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)
9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity
ASCO SERIES 185 Power Transfer Switches
ASCO SERIES 185 Power Transfer Switches 4-hour protection no matter when trouble strikes ASCO Series 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... Your business or home from
How To Operate A Gec Transfer Switch Open Transition 40 2000 Amp Power Supply
GTEC Transfer switch open transition 40 2000 amp Description GTEC transfer switches combine reliability and flexibility in a small, economical package for transferring loads between a utility and a generator
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
Applications. Remote Display Mounting Kits
June 200 Sheet 105 Surge Protection Products TVSS General Description Clipper Power System Visor Series.1-5 Clipper Power System Visor Series General Description Eaton s Cutler-Hammer leading-edge surge
Series TS 870 100-1200 Amp. Automatic Transfer Switches
Series TS 870 100-1200 Amp Automatic Transfer Switches A Regal Brand TS 870 AUTOMATIC TRANSFER SWITCHES THOMSON POWER SYSTEMS TS 870 AUTOMATIC TRANSFER SWITCHES OFFER THE FOLLOWING OUTSTANDING FEATURES:
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500
Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Description Firetrol FTA1500 Primary Resistance Fire Pump Controllers use resistors in the line to reduce line voltage
FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE
FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE SBP1100J FTA1100J Diesel Engine Fire Pump Controllers Product Description Description Firetrol combined automatic and manual Mark
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
Transfer switch BTPC open, closed or delayed transition
Transfer switch BTPC open, closed or delayed transition 150-4000 Amp Description The Cummins Power Generation BTPC series bypass isolation transfer switch combines an automatic transfer switch with a drawout
Bulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
Corner-Grounded Delta (Grounded B Phase) Systems
Data Bulletin 2700DB0202R03/12 09/2012 Replaces 2700DB0202R2/09 dated 02/2009 Corner-Grounded Delta (Grounded B Phase) Systems Class 2700 Retain for future use. Introduction Corner-grounded delta systems
Submit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
SUGGESTED SPECIFICATION for Service Entrance Automatic Transfer Switches
PART 1 GENERAL 1.01 Scope SUGGESTED SPECIFICATION for Service Entrance Automatic Transfer Switches Division 16 - Electrical Standby Power Generator Systems A. Furnish and install service entrance automatic
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
Sentron Series Circuit Breakers
Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A
SURGE PROTECTIVE DEVICES (SPDs) INTEGRATED UNITS LOW VOLTAGE AC SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS PART 1 GENERAL 01 02 03 SCOPE The Contractor shall furnish and install the Surge Protective
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
STRATO LED Drivers 70W, Single output
Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED
PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
Continuous Power... Continuous Protection
Series 165 We Keep Your Power On Continuous Power... Continuous Protection An Automatic Transfer Switch helps prevent... Your business or home from losing power during bad weather or utility power equipment
38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
CPS 100 480Y S K CPS 100 480Y S C
Ref. No. 1299 Visor Series Ordering Guidelines Table.1-4. Retrofit Surge Protection Products TVSS General Description Clipper Power System Visor Series CPS 100 480Y S K.1-9 Surge Ratings 100 = /phase 120
26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B
SURGE PROTECTIVE DEVICES (SPDs) EXTERNAL SIDEMOUNT UNITS LOW VOLTAGE AC SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION PART 1 GENERAL 01 02 03 SCOPE The Contractor shall furnish and install the Surge Protective
Arc Terminator Active Arc-Resistant Switchgear
Arc Terminator Active Arc-Resistant Switchgear Increasing safety and productivity by extinguishing internal arcing faults within the switchgear. The Square D Arc Terminator from Schneider Electric offers
SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:
SWITCH The Budderfly lighting switch is a Decora style, plug-and-play replacement for your existing building switches. Installing a Budderfly adapter transforms your building s existing wiring into the
Project Name: Nortrax Section 26 41 00 Project No: 13-013 SURGE PROTECTION DEVICES Page 1
Page 1 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Divisions 1 Specification sections apply to
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting
NRG Intelligent Engine Start Battery Charger The Smart Choice for Mission-Critical Engine Starting Fast, accurate, mission-critical charging gives best starting reliability 4-rate, temperature-compensated
Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1
How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to
CTS SERIES AUTOMATIC TRANSFER SWITCH
CTS SERIES AUTOMATIC TRANSFER SWITCH The Cat CTS Series Automatic Transfer Switch (ATS) is configurable for applications requiring the dependability and ease of operation found in a full featured power
Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers
Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Catalog 2004 Class 601 CONTENTS Description..............................................Page INTRODUCTION.............................................
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE
WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE SBP1930-61 FTA1930 Digital Solid State Starting Electric Fire Pump Controllers Product Description Fire Pump Controllers for Business-Critical Continuity
3500/62 Process Variable Monitor
3500/62 Process Variable Monitor Description The 3500/62 Process Variable Monitor is a 6-channel monitor for processing machine critical parameters (pressures, flows, temperatures, levels, etc.) that merit
Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930
Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930 Description Firetrol FTA1930 Digital Solid State Starting Fire Pump Controllers feature soft start, soft stop and
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fire pumps
Owner s Manual. For Automatic Transfer Switch. 100-200 Amp, Service Entrance/Non-Service Entrance
Owner s Manual For Automatic Transfer Switch 100-200 Amp, Service Entrance/Non-Service Entrance Model Numbers RTST100A3 RTSP100A3 RTST150A3 RTST200A3 RTSP200A3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU5000RT4UHV Description Tripp Lite SU5000RT4UHV 5000VA / 5kVA /
Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter
FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
ATC-300 Automatic Transfer Switch Controller
ATC-300 Technical Data New Information Technical Data Page 2 Effective: May 2004 ATC-300 Introduction The Cutler-Hammer ATC-300 from Eaton s Electrical business is a comprehensive, multi-function, microprocessor-based
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial MODEL NUMBER: SMART2200RM2U Highlights 2.2kVA / 2200VA / 1920W line interactive 2U
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Secondary Unit Substations
14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically
Analog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms
Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility
Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services
Circuit Breakers and Switchgear Thomas Greer Director of Engineering TLG Services Presentation Outline Switchgear Definition Overcurrent Protection Devices Circuit Breaker Trip Curves and Coordination
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
SECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility
Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Catalog 2800CT1001R02/13 2013 Class 2800 CONTENTS Description............................................ Page 2 Indoor Charging
Sample - No Commercial Use
COMPLETE REVISION October 2010 Electrical PIP ELSSG01 Design and Fabrication of Low-Voltage Metal-Enclosed AC Power Circuit Breaker Switchgear PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
DIESEL GENERATOR SETS
DIESEL SETS STANDBY Standby Prime Model kw (kva) kw (kva) D175-2* 175 (218.8) 157.5 (196.9) *Tier 3 EPA Approved, Emissions Certified Picture shown may not reflect actual package FEATURES SET Complete
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Westinghouse AB DE-ION Current Limiting Circuit Breakers
Cutler-Hammer Westinghouse & Cutler-Hammer Products Five Parkway Center Pittsburgh, Pennsylvania, U.S.A. Application Data -C Page October Mailed to: E/-A Time/Current Characteristic Curves for Westinghouse
Rotary Disconnect Switch Specifications
Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources
Tmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
MAJORSINE Power Inverter
MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions
AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A
AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic
Industrial Generator Set Accessories
Industrial Generator Set Accessories Weather/Sound Enclosure and Subbase Fuel Tank Package Applicable to the following: 40REOZJC 50/60REOZJD 80/100/150/200REOZJF 125/180REOZJG 230-275REOZJE 300REOZJ Enclosure
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
Thermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
O & M Manual for the 50-400A EGSX Transfer Switch
Contents Description Page 1. Introduction...2 2. Receiving, Handling, and Storage... 5 3. Equipment Description... 6 4. Installation and Wiring... 6 5. Functional Testing... 18 6. Maintenance and Component
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
FP-4000 Feeder Protection
FP-4000 Feeder Protection Technical Data TD02602007E Effective September 2007 Supersedes TD02602003E Pages 1 8, Dated March 2006 FP-4000 FP-4000 Product Description........................... 2 Application
Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased