1 Options Guide - English PRIMERGY RX200 S6 Server Options Guide Edition November 2011
2 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by to Certified documentation according to DIN EN ISO 9001:2000 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2000. cognitas. Gesellschaft für Technik-Dokumentation mbh Copyright and Trademarks Copyright 2010 Fujitsu Technology Solutions GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers. The contents of this manual may be revised without prior notice. Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. No part of this manual may be reproduced in any form without the prior written permission of Fujitsu. Microsoft, Windows, Windows Server, and Hyper V are trademarks or registered trademarks of Microsoft Corporation in the USA and other countries. Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the USA and other countries.
3 Before reading this manual For your safety This manual contains important information for safely and correctly using this product. Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure these safety notes are understood before using the product. Keep this manual and the manual "Safety Notes and Regulations" in a safe place for easy reference while using this product. Radio interference This product is a "Class A" ITE (Information Technology Equipment). In a domestic environment this product may cause radio interference, in which case the user may be required to take appropriate measures. VCCI-A Aluminum electrolytic capacitors The aluminum electrolytic capacitors used in the product's printed circuit board assemblies and in the mouse and keyboard are limited-life components. Use of these components beyond their operating life may result in electrolyte leakage or depletion, potentially causing emission of foul odor or smoke. As a guideline, in a normal office environment (25 C) operating life is not expected to be reached within the maintenance support period (5 years). However, operating life may be reached more quickly if, for example, the product is used in a hot environment. The customer shall bear the cost of replacing replaceable components which have exceeded their operating life. Note that these are only guidelines, and do not constitute a guarantee of trouble-free operation during the maintenance support period. High safety use This product has been designed and manufactured for general uses such as general office use, personal use, domestic use and normal industrial use. It has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk to life or body if such safety cannot be ensured. RX200 S6 Options Guide
4 These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, air traffic control, traffic control in mass transport systems, medical devices for life support, and missile guidance control in weapons systems (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use. Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused by lightning. To prevent a momentary voltage drop, use of an AC uninterruptible power supply is recommended. (This notice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA, the Japan Electronics and Information Technology Industries Association.) Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan. Documents which contain such technology should not be exported from Japan or transferred to non-residents of Japan without first obtaining authorization in accordance with the above law. Harmonic Current Standards This product conforms to harmonic current standard JIS C Only for the Japanese market: About SATA hard disk drives The SATA version of this server supports hard disk drives with SATA / BC-SATA storage interfaces. Please note that the usage and operation conditions differ depending on the type of hard disk drive used. Please refer to the following internet address for further information on the usage and operation conditions of each available type of hard disk drive: Options Guide RX200 S6
5 Only for the Japanese market: I Although described in this manual, some sections do not apply to the Japanese market. These options and routines include: CSS (Customer Self Service) RX200 S6 Options Guide
6 Options Guide RX200 S6
7 Contents 1 Preface Concept and target groups Documentation overview Expansions and conversions Notational conventions Procedure Safety instructions Preparation Pulling the server out of the rack Opening the server Removing the air duct Main memory Memory modules Expanding the main memory Processors Installing a second processor Replacing the processor Replacing the heat sink Accessible drive RX200 S6 Options Guide
8 Contents 7.1 Installing a SATA DVD drive HDD modules Installing additional HDD cage Expansion cards and ibbu Installing an expansion card Installing a modular RAID controller Installing an ibbu Further options Trusted Platform Module (TPM) USB Flash Module (UFM) Completion Installing the air duct Closing the server Appendix Cabling Index Options Guide RX200 S6
9 1 Preface The PRIMERGY RX200 S6 rack server is a universal and high-performance platform designed for a whole range of application areas in data center and server farm concepts. The ultra-compact rack server is ideal for web services and solutions such as caching, gateway and firewall applications. Other application areas include front-end solutions (tier 1) in modern multi-tier configurations, and service and appliance solutions. The PRIMERGY RX200 S6 offers a balanced architecture that incorporates next generation main memory (DDR3) and I/O technologies (PCIe Gen2). The backplane is already provided for SAS 2.0 and 6 Gbit/s SAS and the chipset prepared for the next generation of 6-core processors. High performance, scalability, impressive reliability and excellent extension options are combined in a powerful design. The Cool-safe cooling concept with improved air flow cooling technology (honeycomb design) ensures the highest possible performance of the processors at work; at the same time, the system is extremely reliable thanks to the reduced heat dissipation. The highly compact server occupies just one height unit (HU) in the rack. 1.1 Concept and target groups This Options Guide shows you how to extend and upgrade your server. V CAUTION! The activities described in this manual may only be performed by technical specialists. I The installation and removal of the hot-plug components is described in the Operating Manual supplied with the server. RX200 S6 Options Guide 9
10 Preface 1.2 Documentation overview More information on your PRIMERGY RX200 S6 can be found in the following documents: "Quick Start Hardware - PRIMERGY RX200 S6" leaflet " はじめにお 読 みください -PRIMERGY RX200 S6" for the Japanese market (only included as a printed copy) "Quick Start Software - Quick Installation Guide" DVD booklet (only included with the ServerView Suite as a printed copy) except for the Japanese market "Safety notes and other important information" manual " 安 全 上 の 注 意 およびその 他 の 重 要 情 報 " for the Japanese market "Warranty" manual " 保 証 書 " for the Japanese market "ServerView Suite Local Service Concept - LSC" manual "Returning used devices" manual and "Service Desk" leaflet " サポート&サービス " for the Japanese market "PRIMERGY RX200 S6 Server Operating Manual" "PRIMERGY RX200 S6 Server Options Guide" "System Board D3031 for PRIMERGY RX200 S6 Technical Manual" "D3031 BIOS Setup Utility for RX200 S6" manual 10 Options Guide RX200 S6
11 Preface I PRIMERGY manuals are available in PDF format on the ServerView Suite DVD 2. The ServerView Suite DVD 2 is part of the ServerView Suite supplied with every server. If you no longer have the ServerView Suite DVDs, you can obtain the relevant current versions using the order number U15000-C289 (the order number for the Japanese market: please refer to the configurator of the server The PDF files of the manuals can also be downloaded free of charge from the Internet. The overview page showing the online documentation available on the Internet can be found using the URL (for EMEA market): The PRIMERGY server documentation can be accessed using the Industry standard servers navigation option. For the Japanese market please use the URL: Further sources of information: PRIMERGY Abbreviations and Glossary on the ServerView Suite DVD 2 Manual for the monitor Documentation for the boards and drives Operating system documentation Information files in your operating system RX200 S6 Options Guide 11
12 Preface 1.3 Expansions and conversions Main memory The system board offers 12 slots for memory modules. 6 memory slots can be used in mono processor configurations. Second processor The system board can be upgraded with a second processor. Only processors of the same type may be used on the system board. The second processor must have the same clock frequency as the first. Accessible drive In the version with a maximum of six HDD modules, a 5.25 inch bay is available for a DVD drive (SATA interface) with a height of 0.5 inches. HDD modules The server can accommodate two further HDD modules instead of the DVD drive. To do this, you must install a conversion kit consisting of an additional HDD cage and a HDD backplane for up to 8 HDD modules. I The conversion kit is only available for the EMEA market. Expansion cards in the PCI Express slots The system board offers two slots with a PCI Express x8 interface and one slot with a PCI Express x4 interface (exclusively for modular RAID controllers): Expansion cards can only be installed using three-slot riser cards. The riser cards provide three slots at a right angle to the system board (two slots for PCIe controllers and one slot for a RAID controller). Intelligent Battery Backup Unit You can add an ibbu (intelligent Battery Backup Unit) to the optional modular RAID controller to ensure data integrity in the event of a power failure. 12 Options Guide RX200 S6
13 Preface Trusted Platform Module (TPM) A Trusted Platform Module (TPM) for safer storage of keys can be implemented as an option. This module enables programs from third party manufacturers to store key information (e.g. drive encryption using Windows Bitlocker Drive Encryption). The TPM is activated via the BIOS system (for more information, refer to the D3031 BIOS Setup Utility for RX200 S6" manual). V CAUTION! When using the TPM, note the program descriptions provided by the third party manufacturers. You must also create a backup of the TPM content. To do this, follow the third party manufacturer's instructions. Without this backup, if the TPM or the system board is faulty you will not be able to access your data. If a failure occurs, please inform your service about the TPM activation before it takes any action, and be prepared to provide them with your backup copies of the TPM content. USB Flash Module (UFM) The server can be equipped with a USB Flash Module (UFM). This module can be used as optional memory for software (e.g. VMware) or as a software dongle. RX200 S6 Options Guide 13
14 Preface 1.4 Notational conventions The following notational conventions are used in this manual: Text in italics "Quotation marks" V CAUTION! I indicates commands or menu items. indicate names of chapters and terms that are being emphasized. describes activities that must be performed in the order shown. pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data. indicates additional information, notes and tips. 14 Options Guide RX200 S6
15 2 Procedure V CAUTION! The actions described in this manual shall be performed by technical specialists. A technical specialist is a person who is trained to install the server including hardware and software. Repairs to the device that do not relate to CSS failures shall be performed by service personnel. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability. Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment. First of all, carefully read the safety instructions in the chapter "Safety instructions" on page 17. Make sure that all necessary manuals (see the section "Documentation overview" on page 10) are available; print the PDF files if required. Most importantly, you will need the Operating Manual for the server and the Technical Manual for the system board. Shut the server down correctly, switch it off, disconnect the power cords and open the server as described in the chapter "Preparation" on page 25. Carry out the expansion or upgrade of your server as described in the pertinent chapter. I Installation and removal of the hot-plug components are described in the Operating Manual. Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 73. Start the operating system and make the appropriate configuration if necessary (see the Operating Manual). I For the latest information on optional products provided for the RX200 S6 see the configurator of the server: (for the EMEA market) (for the Japanese market) RX200 S6 Options Guide 15
16 16 Options Guide RX200 S6
17 3 Safety instructions I The following safety instructions are also provided in the manual "Safety Notes and Regulations". This device meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the server in the intended environment, please contact your sales outlet or our customer service team. V CAUTION! The actions described in this manual shall be performed by technical specialists. A technical specialist is a person who is trained to install the server including hardware and software. Repairs to the device that do not relate to CSS failures shall be performed by service personnel. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability. Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment. Before installing/removing internal options to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cords from the power outlet. Failure to do so can cause electric shock. RX200 S6 Options Guide 17
18 Safety instructions Before starting up V CAUTION! During installation and before operating the device, observe the instructions on environmental conditions for your device. If the device is brought in from a cold environment, condensation may form both inside and on the outside of the device. Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed. Transport the device only in the original packaging or in packaging that protects it from knocks and jolts. Installation and operation V CAUTION! This unit should not be operated in ambient temperatures above 35 C. If the unit is integrated into an installation that draws power from an industrial power supply network with an IEC309 connector, the power supply's fuse protection must comply with the requirements for nonindustrial power supply networks for type A connectors. The unit automatically adjusts itself to a mains voltage in a range of 100V - 127V / 200V - 240V. Ensure that the local mains voltage lies within these limits. This device must only be connected to properly grounded power outlets or insulated sockets of the rack's internal power supply with tested and approved power cords. Ensure that the device is connected to a properly grounded power outlet close to the device. 18 Options Guide RX200 S6
19 Safety instructions V CAUTION! Ensure that the power sockets on the device and the properly grounded power outlets are freely accessible. The On/Off button or the main power switch (if present) does not isolate the device from the mains power supply. To disconnect it completely from the mains power supply, unplug all network power plugs from the properly grounded power outlets. Always connect the server and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the server is still running but a peripheral device (e.g. memory subsystem) fails during a power outage. Data cables must be adequately shielded. Ethernet cabling has to comply with EN and EN /2 standards or ISO/IEC standard respectively. The minimum requirement is a Category 5 shielded cable for 10/100 Ethernet, or a Category 5e cable for Gigabit Ethernet. Route the cables in such a way that they do not create a potential hazard (make sure no-one can trip over them) and that they cannot be damaged. When connecting the server, refer to the relevant instructions in this manual. Never connect or disconnect data transmission lines during a storm (risk of lightning hazard). Make sure that no objects (e.g. jewelry, paperclips etc.) or liquids can get inside the server (risk of electric shock, short circuit). In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign bodies), switch off the server immediately, remove all power plugs and contact your sales outlet or customer service team. RX200 S6 Options Guide 19
20 Safety instructions V CAUTION! Proper operation of the system (in accordance with IEC /2 resp. EN /2) is only ensured if the casing is completely assembled and the rear covers for the installation slots have been fitted (electric shock, cooling, fire protection, interference suppression). Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and those relating to telecommunication terminals. If you install other expansions, they may damage the system or violate the safety regulations. Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet. The components marked with a warning notice (e.g. lightning symbol) may only be opened, removed or exchanged by authorized, qualified personnel. Exception: CSS components can be replaced. The warranty is void if the server is damaged during installation or replacement of system expansions. Only set screen resolutions and refresh rates that are specified in the operating manual for the monitor. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service center. Before installing/removing internal options to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cords from the outlet. Failure to do so can cause electric shock. Do not damage or modify internal cables or devices. Doing so may cause a device failure, fire, or electric shock. Devices inside the server remain hot after shutdown. Wait for a while after shutdown before installing or removing internal options. The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. Before handling them, first touch a metal part of the server to discharge static electricity from your body. Do not touch the circuitry on boards or soldered parts. Hold the metallic areas or the edges of the circuit boards. 20 Options Guide RX200 S6
21 Safety instructions V CAUTION! Batteries V CAUTION! Install the screw removed during installation/detaching Internal Options in former device/position. To use a screw of the different kind causes a breakdown of equipment. The installation indicated on this note is sometimes changed to the kind of possible options without notice. Incorrect replacement of batteries may result in a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the Technical Manual for the system board). Replace the lithium battery on the system board in accordance with the instructions in the Technical Manual for the system board. RX200 S6 Options Guide 21
22 Safety instructions Working with CDs/DVDs/BDs and optical drives When working with devices with optical drives, these instructions must be followed. V CAUTION! Only use CDs/DVDs/BDs that are in perfect condition, in order to prevent data loss, equipment damage and injury. Check each CD/DVD/BD for damage, cracks, breakages etc. before inserting it in the drive. Note that any additional labels applied may change the mechanical properties of a CD/DVD/BD and cause imbalance. Damaged and imbalanced CDs/DVDs/BDs can break at high drive speeds (data loss). Under certain circumstances, sharp CD/DVD/BD fragments can pierce the cover of the optical drive (equipment damage) and can fly out of the device (danger of injury, particularly to uncovered body parts such as the face or neck). High humidity and airborne dust levels are to be avoided. Electric shocks and/or server failures may be caused by liquids such as water, or metallic items, such as paper clips, entering a drive. Shocks and vibrations are also to be avoided. Do not insert any objects other than the specified CDs/DVDs/BDs. Do not pull on, press hard, or otherwise handle the CD/DVD/BD tray roughly. Do not disassemble the optical drive. Before use, clean the optical disk tray using a soft, dry cloth. As a precaution, remove disks from the optical drive when the drive is not to be used for a long time. Keep the optical disk tray closed to prevent foreign matter, such as dust, from entering the optical drive. Hold CDs/DVDs/BDs by their edges to avoid contact with the disk surface. 22 Options Guide RX200 S6
23 Safety instructions Do not contaminate the CD/DVD/BD surface with fingerprints, oil, dust, etc. If dirty, clean with a soft, dry cloth, wiping from the center to the edge. Do not use benzene, thinners, water, record sprays, antistatic agents, or silicone-impregnated cloth. Be careful not to damage the CD/DVD/BD surface. Keep the CDs/DVDs/BDs away from heat sources. Do not bend or place heavy objects on CDs/DVDs/BDs. Do not write with ballpoint pen or pencil on the label (printed) side. Do not attach stickers or similar to the label side. Doing so may cause rotational eccentricity and abnormal vibrations. When a CD/DVD/BD is moved from a cold place to a warm place, moisture condensation on the CD/DVD/BD surface can cause data read errors. In this case, wipe the CD/DVD/BD with a soft, dry cloth then let it air dry. Do not dry the CD/DVD/BD using devices such as a hair dryer. To avoid dust, damage, and deformation, keep the CD/DVD/BD in its case whenever it is not in use. Do not store CDs/DVDs/BDs at high temperatures. Areas exposed to prolonged direct sunlight or near heating appliances are to be avoided. I You can prevent damage from the optical drive and the CDs/DVDs/BDs, as well as premature wear of the disks, by observing the following suggestions: Only insert disks in the drive when needed and remove them after use. Store the disks in suitable sleeves. Protect the disks from exposure to heat and direct sunlight. Laser information The optical drive complies with IEC laser class 1. V CAUTION! The optical drive contains a light-emitting diode (LED), which under certain circumstances produces a laser beam stronger than laser class 1. Looking directly at this beam is dangerous. Never remove parts of the optical drive casing! RX200 S6 Options Guide 23
24 Safety instructions Modules with electrostatic-sensitive components Systems and components that might be damaged by electrostatic discharge (ESD) are marked with the following label: Figure 1: ESD label When you handle components fitted with ESDs, you must observe the following points under all circumstances: Remove the power plug before installing or removing components containing ESDs. You must always discharge yourself of static charges (e.g. by touching a grounded object) before working. The equipment and tools you use must be free of static charges. Only touch the components at the positions highlighted in green (touch points). Do not touch any exposed pins or conductors on a component. Use a grounding cable designed for this purpose to connect yourself to the system unit as you install components. Place all components on a static-safe base. I You will find a detailed description for handling ESD components in the relevant European or international standards (DIN EN , ANSI/ESD S20.20). 24 Options Guide RX200 S6
25 4 Preparation V CAUTION! Before removing or attaching covers, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cords from the power outlet. Failure to do so can cause electric shock. Only for rack model: Use the anti-tilt plate to prevent the rack from tipping when installing the rack. Pulling the server out of the rack without having installed the anti-tilt plate may cause the rack to tip over. Only for rack model: Be careful not to pinch fingers or clothes when sliding out the server or pushing it back. Failure to do so may cause injury. Before attaching the cover, make sure no unnecessary parts or tools are left inside the server. Before turning on the server, make sure the cover is closed. Follow the safety instructions in the chapter "Safety instructions" on page 17. RX200 S6 Options Guide 25
26 Preparation 4.1 Pulling the server out of the rack Terminate all applications and shut down the server correctly. If your operating system has not switched off the server, press the On/Off button. Pull all power cords out of the power outlet. Loosen the two knurled screws and pull the server carefully out of the rack as far as it will go. I If the server is not easily accessible once it has been pulled out, remove it from the rack completely. See the Operating Manual for details on how to remove the server from the rack. V CAUTION! At least two people are needed to remove the server from the rack. (For the Japanese market, please refer to " 安 全 上 の 注 意 およびその 他 の 重 要 情 報 ".) 26 Options Guide RX200 S6
27 Preparation 4.2 Opening the server You must remove the fan cover before removing the housing cover. Removing the fan cover Figure 2: Removing the fan cover Push the two green buttons (1) in the direction of the arrow. Lift the fan cover upward and remove it (2). Removing the housing cover Figure 3: Removing the housing cover Use the two green locking levers (see circles) to unlock the housing cover. RX200 S6 Options Guide 27
28 Preparation Figure 4: Using the locking levers Push the green locking levers together as shown (1) and then move them up (2) so that the housing cover is pushed backward slightly. Lift the housing cover upward and remove it. 28 Options Guide RX200 S6
29 Preparation 4.3 Removing the air duct Figure 5: Removing the air duct Lift the air duct upward and remove it. RX200 S6 Options Guide 29
30 Preparation 30 Options Guide RX200 S6
31 5 Main memory V CAUTION! Before installing/removing memory to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cords from the power outlet. Failure to do so can cause electric shock. A memory module consists of parts that are very vulnerable to damage by static electricity, and can easily be damaged by static electricity in the human body. Before handling memory modules, first touch a metal part of the server to discharge static electricity. Do not touch the circuitry on boards and soldered parts. Hold the metallic areas or the edge of the circuit boards. Do not install unauthorized third party memory modules. Doing so may cause electric shock, a fire, or failures. Wait for a sufficient period of time after server shutdown before installing or removing memory modules. Failure to do so may cause burns. When installing or removing memory modules, make sure to remove the screws at the specified points only. Failure to do so may cause injury. It may also cause failures. Touch only the specified part of the printed circuit board. Failure to do so may cause injury. It may also cause failures. Do not insert and remove memory modules repeatedly. Doing so may cause failures. If the memory module has not been correctly inserted, it may cause a fire. Insert the memory module with attention to its direction. If a memory module is installed and you pull the securing clips strongly outward, the memory module pops up. Doing so may cause a device failure. Follow the safety instructions in the chapter "Safety instructions" on page 17. RX200 S6 Options Guide 31
32 Main memory 5.1 Memory modules The 12 slots (6 for each CPU) for main memory are designed for RDIMM (registered DIMM, capacities: 2, 4, 8 and 16 GB) as well as for UDIMM (unbuffered DIMM, capacity 2 GB) memory modules. The maximum main memory is for installing UDIMM memory modules 24 GB (12x 2 GB), for installing RDIMM memory modules 192 GB (12x 16 GB). Mixing both types of memory modules is not supported and leads to an error message. When using Westmere-EP processors LV-DIMMs (low voltage DIMMs) can be used. There are three modes of operation for the main memory: Independent Channel Mode / Performance Mode (recommended) Mirrored Channel Mode Spare Channel Mode Depending on the mode of operation there are different population requirements. I The types of memory modules and the modes of operation are described in the Technical Manual or in the configurator of the server. I The current configurator can be found under: (for the EMEA market) (for the Japanese market) Notes on equipping Equipping always starts at DIMM slot 1A. The minimum memory configuration is 1 DIMM per system board in Independent Channel Mode. Memory modules with different clock rates may be mixed. The system automatically adjusts itself to the lowest clock rate. Single and dual and quad rank memory modules may be mixed. Install the memory module with the highest number of ranks into the slot with the lowest number (e.g. modul typ 4GB 2Rx4 into slot DIMM1A and modul typ 4GB 1Rx4 in slot DIMM2A). 32 Options Guide RX200 S6
33 Main memory In the case of same number of ranks install the memory module with the highest capacity into the slot with lowest number (e.g. 8GB 2Rx4 modules (DIMM-1A) before 4GB 2Rx4 modules (DIMM-2A)). In Mirrored Channel Mode and in Spare Channel Mode, memory modules of different capacities may be mixed on a bank by bank basis. The assignment of the DIMM slots to the memory banks and channels is imprinted on the system board next to the DIMM slots. 5.2 Expanding the main memory Open the server as described in the chapter "Preparation" on page 25. Remove the air duct as described in the section "Removing the air duct" on page Figure 6: Removing a memory module Press the securing clips on both sides of the memory slot concerned outward. If the slot was equipped: pull the memory module out of the slot (2). RX200 S6 Options Guide 33
34 Main memory Figure 7: Installing a memory module Carefully press the memory module into the slot (1) until the securing clips on both sides of it engage (2). Reinstall the air duct as described in the section "Installing the air duct" on page 73. Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page Options Guide RX200 S6
35 6 Processors V CAUTION! Before installing/removing processors to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cords from the power outlet. Failure to do so can cause electric shock. Do not touch the circuitry on boards and soldered parts. Hold the metallic areas or the edge of the circuit boards. When adding a processor, be sure to add memory into "DIMM 1D" additionally. Refer to chapter "Main memory" on page 31 for the installation of the memory. When installing the processor, be careful not to bend the pins of the processor socket. Follow the safety instructions in the chapter "Safety instructions" on page 17. V CAUTION! Processors are modules which can react extremely sensitively to electrostatic discharges and which must therefore always be handled with care. After a processor has been removed from its protective sleeve or from its socket, place it with its smooth side down on a nonconducting, antistatic surface. Never push a processor over a surface. RX200 S6 Options Guide 35
36 Processors 6.1 Installing a second processor The system board can be upgraded with a second processor. The upgrade kit consists of a processor and a heat sink. V CAUTION! Only processors of the same type may be used on the system board. That means the number of the internal processor cores as well as the primary clock and the FSB frequency have to be the same. For dual operation, use a suitable multiprocessor operating system. Open the server as described in the chapter "Preparation" on page 25. Remove the air duct as described in the section "Removing the air duct" on page Figure 8: Opening the processor holder and removing the socket cover Press the spring clip downward and outward. Fold back the spring clip (1). Fold back the processor holder (2). Hold the socket cover by the two grips between your thumb and index finger and lift it vertically upward (3). 36 Options Guide RX200 S6
37 Processors Figure 9: Inserting and locking the processor Hold the processor between your thumb and index finger and align it at the socket coding (see circle). V CAUTION! The processor can only be installed in one particular direction. Place the processor in the socket with great care (1). V CAUTION! Do not bend the spring contacts of the processor socket. Never touch the underside of the processor. Even light contaminants, such as oil from human skin, can destroy the processor or impair its functionality. Close the processor holder (2). Lock the processor in the socket by returning the spring clip to its original position (3). RX200 S6 Options Guide 37
38 Processors Figure 10: Installing the heat sink Remove the protective cover on the underside of the heat sink. V CAUTION! Do not touch the thermal paste on the underside of the heat sink. Place the heat sink on the processor as shown. Fasten the heat sink by tightening the four screws in a crossover pattern (see circles). V CAUTION! Never install a processor without a heat sink as otherwise the processor may overheat, causing the possible failure of the processor and system board. Reinstall the air duct as described in the section "Installing the air duct" on page 73. Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page Options Guide RX200 S6
39 Processors 6.2 Replacing the processor V CAUTION! Only processors of the same type may be used on the system board. That means the number of the internal processor cores as well as the primary clock and the FSB frequency have to be the same. For dual operation, use a suitable multiprocessor operating system. Open the server as described in the chapter "Preparation" on page 25. Remove the air duct as described in the section "Removing the air duct" on page 29. Figure 11: Removing the heat sink Loosen the four screws of the heat sink in a crossover pattern. Loosen the heat sink carefully by turning it back and forth. Then lift it up and off. Remove the residual thermal paste from the underside of the heat sink. Clean the underside of the heat sink using a lint-free cloth. RX200 S6 Options Guide 39
40 Processors Figure 12: Removing an old processor Press the spring clip downward and outward. Fold back the spring clip (1). Fold back the processor holder (2). Lift the installed processor carefully out of the socket (3). V CAUTION! Do not bend the spring contacts of the processor socket Figure 13: Inserting and locking a new processor Hold the new processor between your thumb and index finger and align it at the socket coding (see circle). V CAUTION! The processor can only be installed in one particular direction. Place the new processor in the socket with great care (1). V CAUTION! Do not bend the spring contacts of the processor socket. Never touch the underside of the processor. Even light contaminants, such as oil from human skin, can destroy the processor or impair its functionality. 40 Options Guide RX200 S6
41 Processors Close the processor holder (2). Lock the processor in the socket by returning the spring clip to its original position (3). Apply a small amount of thermal paste to the upper side of the new processor. Ensure a thin and even distribution of the thermal paste. Place the heat sink on the processor (see figure 10 on page 38). Fasten the heat sink by tightening the four screws in a crossover pattern. Reinstall the air duct as described in the chapter "Completion" on page 73. Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 73. RX200 S6 Options Guide 41
42 Processors 6.3 Replacing the heat sink Open the server as described in the chapter "Preparation" on page 25. Remove the air duct as described in the section "Removing the air duct" on page 29. Remove the four screws of the heat sink in a crossover pattern (see figure 11 on page 39). Loosen the heat sink carefully by turning it back and forth. Then lift it up and off. Clean the upper side of the processor using a lint-free cloth. I New heat sinks come with thermal paste already applied. When reusing used heat sinks, you need to apply thermal paste. Place the heat sink on the processor (see figure 10 on page 38). Fasten the heat sink by tightening the four screws in a crossover pattern (see figure 10 on page 38). Reinstall the air duct as described in the section "Installing the air duct" on page 73. Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page Options Guide RX200 S6
43 7 Accessible drive V CAUTION! Before installing/removing an accessible drive to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cords from the power outlet. Failure to do so can cause electric shock. When installing an accessible drive, hold it by the side. Applying force to the top may cause failures. Do not touch the circuitry on boards and soldered parts. Hold the metallic areas or the edge of the circuit boards. The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. Before handling them, first touch a metal part on the server to discharge static electricity from your body. Before installing an internal accessible drive, see the manual for the accessible drive. When forcing an accessible drive into a server, be careful so as not to pinch the cable etc. connected to an accessible drive. Follow the safety instructions in the chapter "Safety instructions" on page 17. RX200 S6 Options Guide 43
44 Accessible drive 7.1 Installing a SATA DVD drive The optical drive must be inserted in a mounting frame before sliding it in the server. The parts required for the installation are shown in the photo below: Figure 14: Parts required for installing the SATA DVD drive 1 Mounting frame 2 DVD rive d 3 Cable 4 Screws for fastening the cable Open the server as described in the chapter "Preparation" on page 25. First remove the dummy module by pushing it forward out of the housing (see figure 19 on page 49). I In order to be able to push out the DVD drive or the dummy module, you must press the lock on the side (see oval) sideways. V CAUTION! Keep the dummy module for future use. If you remove the accessible drive again and do not replace it with a new one, the dummy module must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures. 44 Options Guide RX200 S6
45 Accessible drive Figure 15: Connecting the DVD cable Connect the white connector of the DVD cable to the corresponding connector on the HDD backplane (see arrow). Connect the small black connector of the DVD cable to the connector SATA ODD on the system board (see the cabling plans in the Appendix). 1 2 Figure 16: Position of the pins in the mounting frame and the openings on the DVD drive Insert the DVD drive into the mounting frame so that the plastic pins (1) on both sides of the mounting frame are inserted into the openings (2) on the outsides of the drive. RX200 S6 Options Guide 45
46 Accessible drive Figure 17: DVD drive ready to be installed Push the DVD drive into the slot from the outside until it engages. Connect the free black connector of the DVD cable to the DVD drive. Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page Options Guide RX200 S6
47 8 HDD modules V CAUTION! Before installing/removing an HDD module to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cords from the power outlet. Failure to do so can cause electric shock. When installing an HDD module, hold it by the side. Applying force to the top may cause failures. Do not touch the circuitry on boards and soldered parts. Hold the metallic areas or the edge of the circuit boards. The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. Before handling them, first touch a metal part on the server to discharge static electricity from your body. Follow the safety instructions in the chapter "Safety instructions" on page 17. RX200 S6 Options Guide 47
48 HDD modules 8.1 Installing additional HDD cage The server can accommodate two further HDD modules instead of the DVD drive. To do this, you need a conversion kit consisting of the following parts: Figure 18: Parts required for installing the additional HDD cage 1 HDD backplane for up to 8 HDD modules 2 Second SAS cable 3 Dummy HDD (for possible empty HDD bay) 4 HDD cage for up to two additional HDD modules I The conversion kit is only available for the EMEA market. 48 Options Guide RX200 S6
49 HDD modules Open the server as described in the chapter "Preparation" on page 25. Removing an existing DVD drive or dummy module Disconnect the DVD cable from the system board and from the HDD backplane. Figure 19: Removing the DVD drive or dummy module Remove the DVD drive or the dummy module by pushing it forward out of the housing. I In order to be able to push out the DVD drive or the dummy module, you must press the lock on the side (see oval) sideways. RX200 S6 Options Guide 49
50 HDD modules Removing the DVD drive cage Figure 20: Removing the DVD drive cage Loosen the screw on the right hand side (see circle) and push the DVD drive cage outward in the direction of the arrow. 50 Options Guide RX200 S6
51 HDD modules Removing the existing HDD backplane (6x HDD) Remove all HDD modules from the housing. Figure 21: Removing the HDD backplane Disconnect all cables from the HDD backplane (see circle). Lift the HDD backplane over the metal bars (see arrows) and then remove it. Installing the new HDD backplane (8x HDD) Place the new HDD backplane (8x HDD) on the metal bars (see arrows in figure 21) and press the HDD backplane down carefully. Connect all the required cables to the HDD backplane (see figure "Cabling for up to 8 HDD modules with optional RAID controller" on page 80). RX200 S6 Options Guide 51
52 HDD modules Installing the HDD cage Figure 22: Installing the HDD cage Push the HDD cage into the housing. Fasten the HDD cage with one screw (see circle). 52 Options Guide RX200 S6
53 HDD modules Inserting the HDD modules HDD #6 HDD #7 Figure 23: Installation positions of the additional HDD modules Push the additional HDD modules into the two bays (left side = HDD #6, right side = HDD #7) of the HDD cage (description see the Operating Manual). Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 73. RX200 S6 Options Guide 53
54 HDD modules 54 Options Guide RX200 S6
55 9 Expansion cards and ibbu V CAUTION! Before installing/removing expansion cards to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cables from the power outlet. Failure to do so can cause electric shock. The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. Before handling them, first touch a metal part on the server to discharge static electricity from your body. Do not touch the circuitry on boards and soldered parts. Hold the metallic areas or the edge of the circuit boards. Follow the safety instructions in the chapter "Safety instructions" on page 17. RX200 S6 Options Guide 55
56 Expansion cards and ibbu 9.1 Installing an expansion card The server has three slots for PCIe expansion cards. These are integrated in the system using riser cards (see positions (1) - (3) in figure 24). The individual slots can be equipped as follows: Riser card #1: PCIe x8, standard and low-profile expansion cards Riser card #2: PCIe x8, only low-profile expansion cards Riser card #3: PCIe x4, internal, only for (low-profile) RAID controllers I For the installing order see the configurator of the server: (for the EMEA market) (for the Japanese market) Removing the riser card holder Open the server as described in chapter "Preparation" on page Figure 24: Position of riser card holders 1-3 If necessary, disconnect the cables from the relevant expansion card. Lift the required riser card holder upward and remove it. 56 Options Guide RX200 S6
57 Expansion cards and ibbu Installing an expansion card Please read the documentation supplied with the expansion card. Connect any required cables to the expansion card. Installing an expansion card in riser card #1 Figure 25: Riser card holder #1 with rear slot cover Remove the rear slot cover (1) from the riser card holder. I Keep the rear slot cover for future use. If you remove the expansion card, you must replace the rear slot cover to comply with EMC regulations and to satisfy cooling requirements and fire protection measures. Figure 26: Removing the slot cover extension Loosen the screw (1) and remove the slot cover extension (2). RX200 S6 Options Guide 57
58 Expansion cards and ibbu Figure 27: Attaching the slot cover extension to the expansion card Attach the slot cover extension to the slot cover of the expansion card (1). Fasten the slot cover extension with one screw (2). Figure 28: Riser card holder #1 equipped with an expansion card Insert the expansion card into the riser card #1. I Make sure that the rear slot cover is positioned in the designated groove. If necessary, connect the cables to the expansion card and the other components. 58 Options Guide RX200 S6
59 Expansion cards and ibbu Installing an expansion card in riser card #2 Figure 29: Riser card holder #2 with riser card 1 Remove the rear slot cover (1) from the riser card holder. I Keep the rear slot cover for future use. If you remove the expansion card, you must replace the rear slot cover to comply with EMC regulations and to satisfy cooling requirements and fire protection measures. RX200 S6 Options Guide 59
60 Expansion cards and ibbu Figure 30: Riser card holder #2 equipped with an expansion card Insert the expansion card into the riser card of the same height. I Make sure that the rear slot cover is positioned in the designated groove. If necessary, connect the cables to the expansion card and the other components. Installing an expansion card in riser card #3 See section "Installing a modular RAID controller" on page 61. Reinstalling the riser card holder Position the riser card holder over the relevant slot on the system board. Carefully push the riser card holder into the slot by pressing on the green points. Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page Options Guide RX200 S6
61 Expansion cards and ibbu 9.2 Installing a modular RAID controller A modular RAID controller can be installed in the server as an option. Riser card #3 (see figure 24 on page 56) is intended solely for this purpose. Removing riser card holder with riser card #3 Lift the required riser card holder with riser card #3 upward and remove it. Installing a modular RAID controller Please read the documentation supplied with the modular RAID controller. Connect any required cables to the modular RAID controller. Figure 31: Installing the modular RAID controller in riser card #3 Carefully push the modular RAID controller into the slot of riser card #3. I Make sure that the modular RAID controller is positioned correctly (see circle). Installing the riser card holder with riser card #3 Position the riser card holder over the relevant slot on the system board. Carefully push the riser card holder into the slot by pressing on the green points. Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 73. RX200 S6 Options Guide 61
62 Expansion cards and ibbu 9.3 Installing an ibbu V CAUTION! The ibbu (model 25034) used in this server may present a fire or chemical burn hazard if mistreated. Do not disassemble, heat about 100 C (212 F) or incinerate. If you remove the ibbu: Dispose of used ibbu properly. Keep away of children. You can add an ibbu (intelligent Battery Backup Unit) to a modular RAID controller in riser card #3 or a RAID controller in riser card #2 or # Figure 32: ibbu and cable 1 Cable from the ibbu to the RAID controller 2 ibbu 62 Options Guide RX200 S6
63 Expansion cards and ibbu Open the server as described in chapter "Preparation" on page 25. Figure 33: Connecting cable on the underside of the ibbu Insert the ibbu cable into the corresponding connector on the underside of the ibbu (see circle). Figure 34: Position of the ibbu holder in the server RX200 S6 Options Guide 63
64 Expansion cards and ibbu Figure 35: Installing the ibbu Install the ibbu in its holder in the server as follows: 1. Push the ibbu under the two plastic pins of the ibbu holder (1). 2. Press down the ibbu on the opposite side until it clicks into place (2). 64 Options Guide RX200 S6
65 Expansion cards and ibbu Connecting ibbu cable to modular RAID controller in riser card #3 Figure 36: Routing the ibbu cable to modular RAID controller in riser card #3 Route the ibbu cable as shown. I The ibbu cable must pass beneath the power cable that crosses the ibbu cable. Connect the free connector of the ibbu cable to the corresponding connector on the modular RAID controller (see circle). I The connector is protected against polarity reversal, in other words, the connector can only be connected one way round. Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 73. RX200 S6 Options Guide 65
66 Expansion cards and ibbu Connecting ibbu cable to RAID controller in riser card #2 Figure 37: Routing the ibbu cable to RAID controller in riser card #2 Route the ibbu cable as shown. I The ibbu cable must pass under the riser card holder with riser card #3 (see cabling plan on page 81). Connect the free connector of the ibbu cable to the corresponding connector on the RAID controller (see circle). I The connector is protected against polarity reversal, in other words, the connector can only be connected one way round. Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page Options Guide RX200 S6
67 Expansion cards and ibbu Connecting ibbu cable to RAID controller in riser card #1 Figure 38: Routing the ibbu cable to RAID controller in riser card #1 Route the ibbu cable as shown. I The ibbu cable must pass under the riser card holder with riser card #3 (see cabling plan on page 81). Connect the free connector of the ibbu cable to the corresponding connector on the RAID controller (see circle). I The connector is protected against polarity reversal, in other words, the connector can only be connected one way round. Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 73. RX200 S6 Options Guide 67
68 Expansion cards and ibbu 68 Options Guide RX200 S6
69 10 Further options V CAUTION! Follow the safety instructions in the chapter "Safety instructions" on page Trusted Platform Module (TPM) The Trusted Platform Module (TPM) is installed on the system board between riser card slots #1 and #2 (see photo below). The server can be equipped with a TPM (Trusted Platform Module). Figure 39: TPM installation kit 1 TPM (Trusted Platform Module) 3 Special screw for TPM 2 TPM spacer 4 TPM screwdriver insert bit for TPM special screw RX200 S6 Options Guide 69
70 Further options Open the server as described in the chapter "Preparation" on page Figure 40: Installing the TPM module Insert the TPM spacer into the hole on the system board (1). Insert the TPM on the system board (2). Fasten the TPM with the special screw for the TPM (3). Please use the TPM screwdriver insert bit to tighten the special screw. I Do not fasten the screw too tightly (torque value of 0.6 Nm). Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 73. I You can find information on configuring the TPM in the "D3031 BIOS Setup Utility for RX200 S6" manual. 70 Options Guide RX200 S6
71 Further options 10.2 USB Flash Module (UFM) The server can be equipped with a USB Flash Module (UFM). Figure 41: UFM installation kit 1 USB Flash Module (UFM) 3 UFM spacer 2 UFM nylon screw Open the server as described in the chapter "Preparation" on page 25. Lift the required riser card holder with riser card #3 upward and remove it. RX200 S6 Options Guide 71
72 Further options Figure 42: UFM - Position on the system board Connect the USB Flash Module to the system board. The spacer must click into the hole on the system board. Position the riser card holder over the relevant slot on the system board. Carefully push the riser card holder into the slot by pressing on the green points. Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page Options Guide RX200 S6
73 11 Completion V CAUTION! Follow the safety instructions in the chapter "Safety instructions" on page Installing the air duct Figure 43: Installing the air duct Install the air duct. Please note the information shown in the following photos. RX200 S6 Options Guide 73
74 Completion The plastic pin of the air duct must fit into the groove of the system board (see circle). Slot #3 DIMM CPU #1 Figure 44: Position of the plastic pin of the air duct The air duct must be hooked into the fan brackets on the left side and the right side as seen from the front (in this case, the right side): Fan #3/#4 Fan #1/#2 Figure 45: Air duct (right side) 74 Options Guide RX200 S6
75 Completion The air duct must be hooked into the fan brackets on the left side and the right side as seen from the front (in this case, the left side): Fan #11/#12 Figure 46: Air duct (left side) RX200 S6 Options Guide 75
76 Completion 11.2 Closing the server Position the housing cover so that it protrudes about 1 cm over the rear edge. Make sure that each bolt is positioned in the corresponding nut. Push the housing cover forward until it clicks into place. Insert the fan cover. Insert the server into the rack (description see the Operating Manual). V CAUTION! At least two people are needed to position the server in the rack. (For the Japanese market, please refer to " 安 全 上 の 注 意 およびその 他 の 重 要 情 報 ".) Connect all power plugs to the power outlets and switch on the server. 76 Options Guide RX200 S6
77 12 Appendix 12.1 Cabling No. Part no. Description From To 1 A3C Front VGA cable Front panel board System board 2 A3C SATA ODD cable Optical Disk Drive (ODD) 3 A3C SAS HDD cable System board (onboard SATA connector) or RAID controller in slot 3 System board (SATA ODD connector), HDD backplane and ODD HDD backplane (CN1 or CN2) 4 A3C Front panel cable Front panel board System board 5 T Y3987-Vn ibbu cable ibbu RAID controller RX200 S6 Options Guide 77
78 P2 P3 P1 Appendix VGA CN3 Key: DVD drive PSU 1 PSU 2 Front VGA CN2 ussd irmc Slot 2 Slot 3 Slot 1 TPM DIMM 1C DIMM 2C DIMM 1B DIMM 2B DIMM 1A DIMM 2A System Board D3031 CPU 1 Power SATA SAS Data Power distribution board PWR CTRL PWR Front Panel SATA1 SATA ODD Fan 1/2 Fan 3/4 CPU 2 Fan 5/6 Fan 7/8 DIMM 2D DIMM 1D DIMM 2E DIMM 1E DIMM 2F DIMM 1F Fan 9/10 Fan 11/12 Frontpanel Backplane 6x HDD 4 1 CN1 2 3 Figure 47: Cabling for up to 4 HDD modules with onboard SATA controller 78 Options Guide RX200 S6
79 P3 P1 Appendix VGA Front panel CN3 Key: PSU 1 Power distribution board DVD drive PSU 2 P2 PWR Front VGA PWR CTRL Front Panel irmc JP5 ibbu connector RAID controller Ch. A SATA ODD Fan 1/2 Slot 2 Slot 3 Ch. B Fan 3/4 Slot 1 TPM DIMM 1C DIMM 2C DIMM 1B DIMM 2B DIMM 1A DIMM 2A CPU 2 Fan 5/6 Fan 7/8 System Board D3031 CPU 1 DIMM 2D DIMM 1D DIMM 2E DIMM 1E DIMM 2F DIMM 1F Fan 9/10 Fan 11/12 ibbu CN2 Power SATA SAS Data 5 4 CN1 1 Backplane 6x HDD Figure 48: Cabling for up to 6 HDD modules with optional RAID controller RX200 S6 Options Guide 79
80 P3 P1 Appendix VGA Front panel CN3 Key: PSU 1 Power distribution board PSU 2 P2 PWR Front VGA PWR CTRL Front Panel CN2 CN1 irmc JP5 ibbu connector RAID controller Ch. A SATA ODD Fan 1/2 Slot 2 Slot 3 Ch. B Fan 3/4 Slot 1 TPM DIMM 1C DIMM 2C DIMM 1B DIMM 2B DIMM 1A DIMM 2A CPU 2 Fan 5/6 Fan 7/8 System Board D3031 CPU 1 DIMM 2D DIMM 1D DIMM 2E DIMM 1E DIMM 2F DIMM 1F Fan 9/10 Fan 11/12 Power SATA SAS Data ibbu 5 3 Backplane 8x HDD Figure 49: Cabling for up to 8 HDD modules with optional RAID controller 80 Options Guide RX200 S6
81 P3 P1 Appendix VGA Front panel CN3 DVD drive Key: PSU 1 Power distribution board PSU 2 P2 PWR Front VGA PWR CTRL Front Panel CN2 irmc ibbu connector RAID controller JP5 ibbu connector RAID controller Ch. A SATA ODD Fan 1/2 Slot 2 Slot 3 Fan 3/4 Slot 1 TPM DIMM 1C DIMM 2C DIMM 1B DIMM 2B DIMM 1A DIMM 2A CPU 2 Fan 5/6 Fan 7/8 CPU 1 DIMM 2D DIMM 1D DIMM 2E DIMM 1E DIMM 2F DIMM 1F Fan 9/10 Fan 11/12 ibbu CN1 Ch. B System Board D3031 Power SATA SAS Data Backplane 6x HDD Figure 50: Cabling ibbu with optional RAID controller in riser card #2 RX200 S6 Options Guide 81
82 P3 P1 Appendix VGA Front panel CN3 PSU 1 DVD drive Power distribution board CN2 PSU 2 P2 PWR Front VGA PWR CTRL Front Panel irmc Slot 2 JP5 ibbu connector RAID controller Slot 3 Ch. A Ch. B SATA ODD Fan 1/2 Fan 3/4 TPM System Board D3031 DIMM 1C DIMM 2C DIMM 1B DIMM 2B DIMM 1A DIMM 2A CPU 2 Fan 5/6 Fan 7/8 Slot 1 CPU 1 DIMM 2D DIMM 1D DIMM 2E DIMM 1E DIMM 2F DIMM 1F Fan 9/10 Fan 11/12 ibbu CN1 RAID controller ibbu connector Key: Power SATA SAS Data Backplane 6x HDD Figure 51: Cabling ibbu with optional RAID controller in riser card #1 82 Options Guide RX200 S6
83 Index 5.25 inch DVD bay 12 A Accessible drives 12 air duct installing 73 removing 29 D DVD drive 44 E ESD (devices sensitive to electrostatic discharge) 24 expansion cards 12, 57, 61 H HDD backplane (6x HDD) 51 HDD backplane (8x HDD) 51 HDD cage 52 heat sink installing 38 removing 39 I ibbu installing 62 option 12 information, additional 11 intelligent Battery Backup Unit 12 interface PCIe 12 SATA 12 types 32 meaning of the symbols 14 memory configuration 32 modular RAID controller 61 N notational conventions 14 P PCI Express 12 PCIe 12 processor 12, 36 overheating 38 R RDIMM memory modules 32 riser card 12 S SATA 12 T target group 9 thermal paste applying 41 removing 39 TPM 13 Trusted Platform Module 13, 69 U UDIMM memory modules 32 UFM 13, 71 USB Flash Module 13, 71 L laser information 23 light emitting diode (LED) 23 lithium battery 21 M main memory 12 RX200 S6 Options Guide 83
84 Index 84 Options Guide RX200 S6
PRIMERGY TX100 S1. Options Guide
PRIMERGY TX100 S1 Options Guide Edition August 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our
PRIMERGY TX150 S7 Server
Options Guide - English PRIMERGY TX150 S7 Server Options Guide Edition October 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your
Options Guide - English PRIMERGY TX100 S2. Options Guide
Options Guide - English PRIMERGY TX100 S2 Options Guide July 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps
PRIMERGY BX620 S6 Server Blade
Options Guide - English PRIMERGY BX620 S6 Server Blade Options Guide August 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your
PRIMERGY TX100 S3 Server
Upgrade and Maintenance Manual - English PRIMERGY TX100 S3 Server Upgrade and Maintenance Manual February 2014 Comments Suggestions Corrections The User Documentation Department would like to know your
PRIMERGY RX300 S6 Server
Service Supplement - english PRIMERGY RX300 S6 Server Service Supplement Edition March 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.
FUJITSU Server PRIMERGY RX1330 M2
Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX1330 M2 Upgrade and Maintenance Manual December 2015 Comments Suggestions Corrections The User Documentation Department would like to
PRIMERGY Econel 50 Server System
PRIMERGY PRIMERGY Econel 50 Server System Service Supplement Xenia Fierley Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: [email protected] Tel.: (089) 61001-157 Fax: 0 700
PRIMERGY RX200 S8 Server
Upgrade and Maintenance Manual - English PRIMERGY RX200 S8 Server Upgrade and Maintenance Manual June 2015 Comments Suggestions Corrections The User Documentation Department would like to know your opinion
PRIMERGY CX400 S2 Server Enclosure
Upgrade and Maintenance Manual - English PRIMERGY CX400 S2 Server Enclosure Upgrade and Maintenance Manual Edition December 2013 Comments Suggestions Corrections The User Documentation Department would
Operating Manual - English PRIMERGY RX200 S6. Operating Manual
Operating Manual - English PRIMERGY RX200 S6 Operating Manual March 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback
HP ProLiant DL165 G7 Server. Installation Instructions
HP ProLiant DL165 G7 Server Installation Instructions Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 HDD Item 1 Thumbscrews for rack mounting 2 Drive status
StorTrends 3400 Hardware Guide for Onsite Support
StorTrends 3400 Hardware Guide for Onsite Support MAN-3400-SS 11/21/2012 Copyright 1985-2012 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200
PRIMERGY TX100 S2 Server
Operating Manual - English PRIMERGY TX100 S2 Server Operating Manual Edition March 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.
PRIMERGY RX600 S6 Server
Operating Manual - English PRIMERGY RX600 S6 Server Operating Manual July 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback
System Board D2863 for PRIMERGY RX100 S6
Technical Manual - English System Board D2863 for PRIMERGY RX100 S6 Technical Manual Edition February 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion
System Board D2779 for PRIMERGY TX100 S2
Technical Manual - English System Board D2779 for PRIMERGY TX100 S2 Technical Manual Edition June 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion
System Board D3009 for PRIMERGY TX100 S3
Technical Manual - English System Board D3009 for PRIMERGY TX100 S3 Technical Manual Edition May 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion
UPGRADING AND SERVICING GUIDE
UPGRADING AND SERVICING GUIDE HPTouchSmart 610 PC Computer features may vary by model. Removing and Replacing a CD/DVD Drive...2 Removing the CD/DVD Drive... 2 Installing a New CD/DVD Drive... 5 Removing
HP SATA/SAS hard drive and Solid State Drive installation
HP SATA/SAS hard drive and Solid State Drive installation This document describes how to install Serial ATA (SATA) and Serial Attached SCSI (SAS) hard drives or Solid State Drives (SSD) in an internal
HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in
HP Pavilion All-in-One MS200 series PC *579907-001* *579907-001* Printed in Upgrading and Servicing Guide Replacing a Wireless Keyboard or Mouse...2 Before You Begin... 2 Replacing the Keyboard or Mouse...
Compaq Presario Desktop Products. Upgrading and Servicing Guide
Compaq Presario Desktop Products Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to
Upgrading and Servicing Guide
Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed
Small form factor bay converter and hard drive installation
Small form factor bay converter and hard drive installation HP xw6600 and HP xw8600 Workstations This document describes how to convert HP xw6600 and HP xw8600 Workstation 3.5-inch hard drive bays to hold
Power Supply Guide Version 1.0 for D-Show
Power Supply Guide Version 1.0 for D-Show Digidesign 2001 Junipero Serra Boulevard Daly City, CA 94014-3886 USA tel: 650 731 6300 fax: 650 731 6399 Technical Support (USA) tel: 650 731 6100 fax: 650 731
Service Guide. Gateway M275
Service Guide Gateway M275 Contents Replacing Gateway M275 Components.................................... 1 Identifying the convertible tablet PC model...................................... 2 Identifying
Digital Photo Picture Frame. Operation Manual
Digital Photo Picture Frame Operation Manual 20070309 CONGRATULATIONS on your purchase of a Polaroid 7 LCD Digital Photo Picture Frame. Please read carefully and follow all warnings and instructions in
PRIMERGY SX960 S1 Storage Blade
Operating Manual - English PRIMERGY SX960 S1 Storage Blade Operating Manual April 2014 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.
Front Panel Board Cable Replacement Instructions
apple Mac Pro Front Panel Board Cable Replacement Instructions First Steps 1 Shut down computer. Note: Follow these instructions carefully. Failure to do so could damage your equipment and void its warranty.
PRIMERGY TX300 S7 / RX350 S7 Server
Operating Manual - English PRIMERGY TX300 S7 / RX350 S7 Server Operating manual Edition July 2014 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this
FUJITSU Server PRIMERGY RX100 S8
Operating Manual - English FUJITSU Server PRIMERGY RX100 S8 Operating Manual Edition November 2013 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of
FUJITSU Server PRIMERGY TX1330 M2
Operating Manual - English FUJITSU Server PRIMERGY TX1330 M2 Operating Manual Edition November 2015 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of
3.5 Dual Bay USB 3.0 RAID HDD Enclosure
3.5 Dual Bay USB 3.0 RAID HDD Enclosure User Manual August 11, 2011 v1.1 MFG Part # MT2U3-MP BARCODE Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III
PRIMERGY RX100 S6 Server. Operating manual
PRIMERGY RX100 S6 Server Operating manual April 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our
Wall-Mounting your HP computer. User Guide
Wall-Mounting your HP computer User Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall
Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001
Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
TS500-E5. Configuration Guide
TS500-E5 Configuration Guide E4631 Second Edition V2 March 2009 Copyright 2009 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may
NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.
CAUTION: General Safety Instructions Use the following safety guidelines to help ensure your own personal safety and to help protect your equipment and working environment from potential damage. NOTE:
User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC)
User Guide - English FUJITSU Software ServerView Suite Local Service Panels Local Service Concept (LSC) Edition February 2013 Comments Suggestions Corrections The User Documentation Department would like
PRIMERGY TX140 S1 Server
Operating Manual - English PRIMERGY TX140 S1 Server Operating Manual Edition May 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
FUJITSU Server PRIMERGY RX2540 M1
Operating Manual - English FUJITSU Server PRIMERGY RX2540 M1 Operating manual Edition February 2015 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of
FUJITSU Server PRIMERGY CX2550 M2 Server Node
Operating Manual - English FUJITSU Server PRIMERGY CX2550 M2 Server Node Operating Manual Edition November 2015 Comments Suggestions Corrections The User Documentation Department would like to know your
Inspiron 13. Service Manual. 7000 Series. Computer Model: Inspiron 13 7348 Regulatory Model: P57G Regulatory Type: P57G001
Inspiron 13 7000 Series Service Manual Computer Model: Inspiron 13 7348 Regulatory Model: P57G Regulatory Type: P57G001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps
Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure
Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Scale-Out Smart for HPC, Cloud and Hyper-Converged Computing
EasyNote TJ Series. Disassembly Manual
EasyNote TJ Series Disassembly Manual CHAPTER3 Replacing notebook components Preventing static electricity discharge Preparing the work space Required tools Preparing the notebook Adding or replacing memory
SERVICE GUIDE. Gateway Notebook
SERVICE GUIDE Gateway Notebook Contents Replacing Gateway Notebook Components...................................1 Identifying the notebook model......................................... 2 Identifying
Tyan Computer. Transport PX22. Service Engineer s Manual
Tyan Computer Transport PX22 Service Engineer s Manual 1 Precaution To read through the user manual, check all assembly and follow setup process before any operation on this server To keep paper clips,
Server Rack Commissioning
Server Rack Commissioning English 1.0.0 / 2015-04-23 Information about Copyright, Trademarks, Design Patents 2015 Dallmeier electronic The reproduction, distribution and utilization of this document as
Inspiron 15. Service Manual. 3000 Series
Inspiron 15 3000 Series Service Manual Computer Model: Inspiron 15 3541/Inspiron 15 3542/Inspiron 15 3543 Regulatory Model: P40F Regulatory Type: P40F001/P40F002 Notes, Cautions, and Warnings NOTE: A NOTE
Serial ATA to Serial ATA
Serial ATA to Serial ATA Model: MRK-300ST-BK Aluminum Mobile Rack 3-1 3-1 Introduction... 3-3 Mobile Rack Features... 3-3 Unpacking Your Mobile Rack... 3-4 IDE Basics... 3-4 3-2 Hardware Installation...
Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE
Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards 1.2 PACKAGE
EVGA Z97 Classified Specs and Initial Installation (Part 1)
User Guide EVGA Z97 Classified Specs and Initial Installation (Part 1) - 1 - Table of Contents Before you Begin 3 Parts Not in the kit.4 Intentions of the kit 4 Motherboard Specifications 5 Unpacking and
Dell Inspiron 660s Owner s Manual
Dell Inspiron 660s Owner s Manual Computer model: Inspiron 660s Regulatory model: D06S Regulatory type: D06S001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you
Processor Cage Fans, Front and Rear Replacement Instructions
apple Mac Pro Processor Cage Fans, Front and Rear Replacement Instructions First Steps 1 Shut down computer. Note: Follow these instructions carefully. Failure to do so could damage your equipment and
PRIMERGY RX200 S7 Server
Operating Manual - English PRIMERGY RX200 S7 Server Operating Manual Edition April 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.
HP Optical Bay Hard Drive Bracket
HP Optical Bay Hard Drive Bracket Introduction This document describes how to install 8.89 cm (3.5 inch) hard drives in the HP optical bay hard drive bracket and install the bracket in the optical drive
PRIMERGY TX150 S3 Server System
PRIMERGY PRIMERGY TX150 S3 Server System Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: [email protected] Tel.: (089) 61001155 Fax: (++49)
Hard Disk Drive (HDD)
Installation Instructions Hard Disk Drive (HDD) Catalog Number 6189V-35HDDST80, 6189V-35HDDST160 Topic Page About This Publication 1 Important User Information 2 Electrostatic Discharge (ESD) Precautions
aseries A13B Mini Bullet Camera User Manual
aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
Hydra esata. 4-Bay RAID Storage Enclosure. User Manual January 16, 2009 - v1.0
4-Bay RAID Storage Enclosure User Manual January 16, 2009 - v1.0 EN Table of Contents 1 Introduction... 1 1.1 System Requirements... 1 1.1.1 PC Requirements... 1 1.1.2 Mac Requirements... 1 1.1.3 Supported
BladeRunner 4U Blade Server User Manual. December 2004 (Revision A)
BladeRunner 4U Blade Server User Manual December 2004 (Revision A) Copyright Notice The copyright in all material provided in this User Manual is held by Penguin Computing Inc. or by the original creator
4x3.5" Hot-Swap Drive Cage Kit Installation Guide for Intel Server Chassis/System
4x3.5" Hot-Swap Drive Cage Kit Installation Guide for Intel Server Chassis/System Order Number: G23758-002 G23758-002 This document provides instructions for installing the following accessory kit: FUP4X35HSDK
Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server
Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server Advanced Blade Ecosystem the ideal platform for branch offices and mediumsized companies Fujitsu PRIMERGY BX Blade Servers meet all the requirements of
Installation Guide. Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit. Issue: 022808 PN: 883884-07L Rev. A
Installation Guide Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit Issue: 022808 PN: 883884-07L Rev. A ii Copyright Notice 2008, Wyse Technology Inc. All rights reserved. This manual and the
Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 www.akitio.
Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.akitio.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...
FUJITSU Server PRIMERGY RX2520 M1
Operating Manual - English FUJITSU Server PRIMERGY RX2520 M1 Operating manual Edition February 2015 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of
Memory Modules User Guide
Memory Modules User Guide Copyright 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services
FUJITSU Server PRIMERGY RX2530 M2
Operating Manual - English FUJITSU Server PRIMERGY RX2530 M2 Operating Manual Edition January 2016 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of
EVGA X99 Classified Specs and Initial Installation (Part 1)
User Guide EVGA X99 Classified Specs and Initial Installation (Part 1) - 1 - Table of Contents Before you Begin 3 Parts Not in the kit.4 Intentions of the kit 4 Motherboard Specifications 5 Unpacking and
PRIMERGY RX300 S7 Server
Operating Manual - English PRIMERGY RX300 S7 Server Operating manual Edition June 2013 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.
2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN-00076-A
2-3 SAS/SATA II HDD Canister XC-23D1-SA10-0-R USER S MANUAL Document number: MAN-00076-A ii Preface Important Information Warranty Our product is warranted against defects in materials and workmanship
HP 22-in-1 Media Card Reader
HP 22-in-1 Media Card Reader Introduction This document describes how to install the HP 22-in-1 Media Card Reader into an HP Workstations adapter bracket, and then install the media card reader and bracket
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
Intel NUC Kit DC3217IYE User Guide. Intel NUC Kit DC3217IYE
Intel NUC Kit DC3217IYE User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers and with the safety practices
15GAL STEEL OIL DRAIN WITH 110V PUMP
15GAL STEEL OIL DRAIN WITH 110V PUMP OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
Aura SSD. for the 2013 Apple Mac Pro INSTALLATION GUIDE
Aura SSD for the 2013 Apple Mac Pro INSTALLATION GUIDE TABLE OF CONTENTS 1. INTRODUCTION...1 1.1 SYSTEM REQUIREMENTS 1.2 PACKAGE CONTENTS 1.3 ABOUT THIS MANUAL 2. INSTALLATION...2 2.1 PREPARING THE MAC
Internal USB port kit installation
Internal USB port kit installation Introduction The internal USB port kit provides a Type A female USB port compatible with Type A USB devices internal to the computer chassis. This document describes
Data Sheet Fujitsu PRIMERGY BX900 S1 Blade Server
Data Sheet Fujitsu PRIMERGY BX900 S1 Blade Server The Dynamic Cube Fujitsu PRIMERGY BX Blade Servers meet all the requirements of medium-sized companies as well as the branches and data centers of large
OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER
OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER P110 Your battery charger has been engineered and manufactured to Ryobi s high standard for dependability, ease of operation, and operator safety. When properly
Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide
Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide Thank you for buying an Intel RAID Maintenance Free Backup Unit 4. The Intel RAID Maintenance Free Backup Unit 4 supports the Intel
FCC COMPLIANCE STATEMENT FOR AMERICAN USERS
FCC COMPLIANCE STATEMENT FOR AMERICAN USERS This equipment has been tested and found to comply with the limits for a CLASS A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server
Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server High availability for lower expertise
How To Use An Nc Express5800 Card (Nec) With A Remote Management Card (Ec) On A Pc Or Mac Computer (Nemca) With An Ipa/Sda/Sdu) On An Ipad Or
Remote Management Card User s Guide 07/2004 8115-01_RMC CONTENTS Safety Indications... 3 About Remote Management Card... 4 Components... 4 Installation / Removal / Replacement... 5 Installation... 6 Removal...
IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.
THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to
Installation Guide. Wyse C Class 2-GB RAM Upgrade Option Kit. Issue: 092910 PN: 883884-13L Rev. A
Installation Guide Wyse C Class 2-GB RAM Upgrade Option Kit Issue: 092910 PN: 883884-13L Rev. A Copyright Notices 2010, Wyse Technology Inc. All rights reserved. This manual and the software and firmware
LSI MegaRAID SAS 8888ELP Host Bus Adapter installation
LSI MegaRAID SAS 8888ELP Host Bus Adapter installation Introduction This document describes how to install the LSI MegaRAID SAS 8888ELP Host Bus Adapter (HBA) in HP and xw series Workstations. Procedures
PAR Tablet 10 Quick Start Guide
ParTech, Inc. 8383 Seneca Turnpike New Hartford, NY 13413 p.800.458.6898 www.partech.com PAR Tablet 10 Quick Start Guide PN 770505503 This material has been created in order to accommodate a wide range
ProLiant DL380 Generation 2 Server Maintenance and Service Guide
ProLiant DL380 Generation 2 Server Maintenance and Service Guide Second Edition (June 200) Part Number 203840-002 Spare Part Number 228520-00 Compaq Computer Corporation Notice 200 Compaq Computer Corporation
apple Service Source PowerBook G4 (DVI) Updated 4 December 2003 2003 Apple Computer, Inc. All rights reserved.
apple Service Source PowerBook G4 (DVI) Updated 4 December 2003 2003 Apple Computer, Inc. All rights reserved. apple Service Source Upgrades PowerBook G4 (DVI) 2003 Apple Computer, Inc. All rights reserved.
2-SLICE COOL TOUCH TOASTER
2-SLICE COOL TOUCH TOASTER PLA0405 Instruction Manual Due to on-going product improvements, specifications and accessories may change without notice. Actual product may differ slightly to that depicted.
Memory Installation Guide
Memory Installation Guide For ASUSTOR 6 Series NAS Ver.1.0.0.1204 Table of Contents 1. Introduction... 3 1.1. Notes and Precautions... 3 1.2. Parts and Tools Needed... 4 2. Installation Guide... 5 2.1.
Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure
Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure Scale-Out Smart for HPC and Cloud Computing with enhanced energy efficiency The PRIMERGY CX400 Cloud extension servers are Fujitsu
TRIMBLE TX5 3D LASER SCANNER QUICK START GUIDE
TRIMBLE TX5 3D LASER SCANNER QUICK START GUIDE Equipment 1 8 9 5 6 7 4 3 2 The TX5 laser scanner ships with the following equipment: 1 Scanner transport and carry case 6 USB memory card reader 2 AC power
Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: 121312 PN: 883884-35L Rev. A
Installation Guide Wyse D Class 4-GB RAM Upgrade Option Kit Products: D90D7, D90DW Issue: 121312 PN: 883884-35L Rev. A Copyright Notices 2012, Wyse Technology Inc. All rights reserved. This manual and
DD670, DD860, and DD890 Hardware Overview
DD670, DD860, and DD890 Hardware Overview Data Domain, Inc. 2421 Mission College Boulevard, Santa Clara, CA 95054 866-WE-DDUPE; 408-980-4800 775-0186-0001 Revision A July 14, 2010 Copyright 2010 EMC Corporation.
GS-SR112. Rackmount Server System Installation Guide
GS-SR112 Rackmount Server System Installation Guide 1-i Contents 1. SAFETY, CARE AND REGULATORY INFORMATION 1-1 2. INTRODUCTION 2-1 2.1. PREFACE 2-1 2.2. FEATURES 2-1 3. PACKAGE CONTENTS 3-1 4. SYSTEM
HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install
HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install Carrier-Grade Instructions HP Part Number: AM275-9001A Published: July 2012 Edition: 3 Copyright 2009, 2012 Hewlett-Packard Development Company,