1 Operating Manual - English PRIMERGY SX960 S1 Storage Blade Operating Manual April 2014
2 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by to Certified documentation according to DIN EN ISO 9001:2008 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2008. cognitas. Gesellschaft für Technik-Dokumentation mbh Copyright and Trademarks Copyright 2014 Fujitsu Technology Solutions GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers. The contents of this manual may be revised without prior notice. Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. No part of this manual may be reproduced in any without the prior written permission of Fujitsu. Microsoft, Windows, Windows Server, and Hyper V are trademarks or registered trademarks of Microsoft Corporation in the USA and other countries. Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the USA and other countries.
3 Before reading this manual For your safety This manual contains important information for safely and correctly using this product. Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure these safety notes are understood before using the product. Keep this manual and the manual "Safety Notes and Regulations" in a safe place for easy reference while using this product. Radio interference This product is a "Class A" ITE (Information Technology Equipment). In a domestic environment this product may cause radio interference, in which case the user may be required to take appropriate measures. VCCI-A Aluminum electrolytic capacitors The aluminum electrolytic capacitors used in the product's printed circuit board assemblies and in the mouse and keyboard are limited-life components. Use of these components beyond their operating life may result in electrolyte leakage or depletion, potentially causing emission of foul odor or smoke. As a guideline, in a normal office environment (25 C) operating life is not expected to be reached within the maintenance support period (5 years). However, operating life may be reached more quickly if, for example, the product is used in a hot environment. The customer shall bear the cost of replacing replaceable components which have exceeded their operating life. Note that these are only guidelines, and do not constitute a guarantee of trouble-free operation during the maintenance support period. High safety use This product has been designed and manufactured to be used in commercial and/or industrial areas as a server. When used as visual display workplace, it must not be placed in the direct field of view to avoid incommoding reflections (applies only to TX server systems). The device has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk of life or body if such safety cannot be assured. SX960 S1 Operating Manual
4 These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, air traffic control, traffic control in mass transport systems, medical devices for life support, and missile guidance control in weapons systems (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use. Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused by lightning. To prevent a momentary voltage drop, use of an AC uninterruptible power supply is recommended. (This notice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA, the Japan Electronics and Information Technology Industries Association.) Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan. Documents which contain such technology should not be exported from Japan or transferred to non-residents of Japan without first obtaining authorization in accordance with the above law. Harmonic Current Standards This product conforms to harmonic current standard JIS C Only for the Japanese market: About SATA hard disk drives The SATA version of this server supports hard disk drives with SATA / BC-SATA storage interfaces. Please note that the usage and operation conditions differ depending on the type of hard disk drive used. Please refer to the following internet address for further information on the usage and operation conditions of each available type of hard disk drive: Operating Manual SX960 S1
5 Only for the Japanese market: I Although described in this manual, some sections do not apply to the Japanese market. These options and routines include: CSS (Customer Self Service) SX960 S1 Operating Manual
6 Operating Manual SX960 S1
7 Contents 1 Preface Concept and target groups for this manual Documentation overview Features Notational conventions Technical data Important notes Safety instructions Electrostatic sensitive device label FCC Class A Compliance Statement RFI suppression Notes on transportation Installation Installation procedure Unpacking a storage blade Installing/removing a storage blade in/from the system unit 23 4 Operation Control and display elements Putting the storage blade into operation Hot-plug components Hot-plug drives SX960 S1 Operating Manual
8 Contents 5.2 Removing/installing the dummy module Installing/removing the HDD/SSD module Optional: Installation / Replacement of BBU / FBU Installing the BBU07/ Preparations Mounting the BBU Mounting the BBU Installing the FBU Preparations Mounting the FBU Replacing the BBU07/ Removing the BBU07/ Installing the BBU07/ Replacing the FBU Removing the FBU Installing the FBU Troubleshooting and tips Drives reported as "dead" when starting system Added drive reported as defective Operating Manual SX960 S1
9 1 Preface The PRIMERGY SX960 S1 storage blade is used as a storage subsystem for the PRIMERGY BX400 S1 and BX900 S1/BX900 S2 blade server. The storage blade comes with 10 bays for 2.5-inch SAS or SATA HDD/SSD modules and occupies two bays in the system unit. Up to two SX960 S1 storage blades can be installed per BX400 S1 and BX900 S1/BX900 S2 system unit. Figure 1: PRIMERGY SX960 S1 storage blade SX960 S1 Operating Manual 9
10 Preface 1.1 Concept and target groups for this manual This operating manual describes how to install, set up and operate your storage blade. It is intended for those responsible for installing the hardware and ensuring that the system runs smoothly. This operating manual contains all the information you need to put your PRIMERGY SX960 S1 storage blade into operation. To understand the various expansion options, you will need to be familiar with the fields of hardware and data transmission and you will require a basic knowledge of the underlying operating system. 1.2 Documentation overview More information on your PRIMERGY SX960 S1 storage blade can be found in the following documents: "Safety Notes and Regulations" manual " 安 全 上 のご 注 意 " for the Japanese market "Warranty" manual " 保 証 書 " for the Japanese market "Returning used devices" manual and "Service Desk" leaflet " サポー ト &サービス " for the Japanese market I All documentation on PRIMERGY hardware and ServerView software is available online from the Fujitsu manuals server at: (global market) (Japanese market) The complete PRIMERGY documentation set can also be downloaded as a DVD ISO image at: ftp://ftp.ts.fujitsu.com/images/serverview/manuals (global market) (Japanese market) 10 Operating Manual SX960 S1
11 Preface 1.3 Features The PRIMERGY SX960 S1 storage blade comes with the following features: MegaRAID SAS Controller The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please refer to the configurator for details. Battery Backup Unit / Flash Backup Unit A Battery Backup Unit (BBU) / Flash Backup Unit (FBU) can optionally be ordered for certain RAID controllers to back up the memory contents of the RAID controller in the event of power failure. 1.4 Notational conventions The following notational conventions are used in this manual: Text in italics "Quotation marks" V CAUTION! I indicates commands or menu items. indicate names of chapters and terms that are being emphasized. describes activities that must be performed in the order shown. pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data. indicates additional information, notes and tips. SX960 S1 Operating Manual 11
12 Preface 1.5 Technical data Electrical data Energy consumption Heat dissipation 70W typ. / 110W max. (fully equipped) 239 BTU/h or 252kJ/h typ./ 376 BTU/h or 396kJ/h max. Compliance with regulations and standards Product safety and ergonomics International IEC /2 Europe Safety EN /2 ergonomics ISO EN EK1-ITB 2003:2007 UL /2 USA / Canada CSA-C Taiwan CNS China GB 4943 Electromagnetic compatibility International CISPRA 24 Europe EN EN EN EN ETS USA / Canada 47CFR part 15 Class A / ICES-003 Taiwan CNS Class A China GB 9245 / GB Japan VCCI Class A / Jeida CE marking to EU directives Low Voltage Directive 2006/95/EC Electromagnetic compatibility 2004/108/EC 12 Operating Manual SX960 S1
13 Preface Certification Product safety Global Europe Germany USA/Canada Japan China/Taiwan CB ENEC GS, CE CSA US / CSA C VCCI BSMI Mechanical specifications Height Depth Width 204 mm (chassis height mm) 508 mm (525 mm incl. lever) 90.5 mm (2 bays in the system unit) Weight Max. 8 kg (fully equipped) Ambient conditions Environment class 3K2 Environment class 2K2 Temperature: EN / IEC 721 Part 3-3 EN / IEC 721 Part 3-2 Operation (3K2) 5 C C Transport (2K2) -20 C C Humidity 10%... 85% (non condensing) Condensation during operation must be avoided! SX960 S1 Operating Manual 13
14 Preface 14 Operating Manual SX960 S1
15 2 Important notes This chapter provides safety instructions which you must observe when handling your storage blade. 2.1 Safety instructions I The following safety instructions are also provided in the manual "Safety Notes and Regulations" or " 安 全 上 のご 注 意 ". This device meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the storage blade in the intended environment, please contact your sales outlet or our customer service team. V CAUTION! The actions described in this manual should only be performed by technical specialists. Equipment repairs should only be performed by service staff. Any failure to observe the guidelines in this manual, and any unauthorized opening or improper repairs could expose the user to risks (electric shock, fire hazards) or damage the equipment. Please note that any unauthorized opening of the storage blade will void the warranty and exempt the manufacturer from all liability. During installation and before operating the device, observe the instructions on environmental conditions for your device (see section "Technical data" on page 12) If the storage blade has been moved from a cold environment, condensation may form both inside and on the outside of the machine. Wait until the storage blade has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not met. SX960 S1 Operating Manual 15
16 Important notes V CAUTION! Only transport the device in its original packaging or in suitable packaging which protects it from knocks and jolts. For the Japanese market, transporting the device with ORIGINAL PACKAGING is not applied. Check that the rated voltage specified on the device's ID plate is the same as the local line voltage. Never connect or disconnect data transmission lines during a storm (lightning hazard). Make sure that no objects (e.g. bracelets or paper clips) fall into or liquids spill into the device (risk of electric shock or short circuit). Note that proper operation of the system (in accordance with IEC /DIN EN ) is guaranteed only if slot covers are installed on all vacant slots and/or dummies on all vacant bays and the housing cover is fitted (cooling, fire protection, RFI suppression). 16 Operating Manual SX960 S1
17 Important notes 2.2 Electrostatic sensitive device label Modules with electrostatic-sensitive components Systems and components that might be damaged by electrostatic discharge (ESD) are marked with the following label: Figure 2: ESD label When you handle components fitted with ESDs, you must observe the following points under all circumstances: Remove the power plug before installing or removing components containing ESDs. You must always discharge yourself of static charges (e.g. by touching a grounded object) before working. The equipment and tools you use must be free of static charges. Only touch the components at the positions highlighted in green (touch points). Do not touch any exposed pins or conductors on a component. Use a grounding cable designed for this purpose to connect yourself to the system unit as you install components. Place all components on a static-safe base. I You will find a detailed description for handling ESD components in the relevant European or international standards (DIN EN , ANSI/ESD S20.20). SX960 S1 Operating Manual 17
18 Important notes 2.3 FCC Class A Compliance Statement If there is an FCC statement on the device, it applies to the products covered in this manual, unless otherwise specified herein. The statement for other products will appear in the accompanying documentation. NOTE: This equipment has been tested and found to comply with the limits for a "Class A" digital device, pursuant to Part 15 of the FCC rules and meets all requirements of the Canadian Interference-Causing Equipment Standard ICES-003 for digital apparatus. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in strict accordance with the instructions, may cause harmful interference to radio communications. However, there is no warranty that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between equipment and the receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. Fujitsu is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Fujitsu. The correction of interferences caused by such unauthorized modification, substitution or attachment will be the responsibility of the user. The use of shielded I/O cables is required when connecting this equipment to any and all optional peripheral or host devices. Failure to do so may violate FCC and ICES rules. WARNING: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. 18 Operating Manual SX960 S1
19 Important notes 2.4 RFI suppression All other equipment which is connected to this product must also have radio noise suppression in accordance with EC Guideline 89/336/EEC. Products which meet this requirement are accompanied by a certificate to that effect issued by the manufacturer and/or bear the CE mark. Products which do not meet this requirement may be operated only with the special permission of the BZT (Bundesamt für Zulassungen in der Telekommunikation). 2.5 Notes on transportation I Only transport the storage blade in its original packaging or in suitable packaging which protects it from knocks and jolts. For the Japanese market, transporting the device with ORIGINAL PACKAGING is not applied. Do not unpack the storage blade until it is at its installation location. SX960 S1 Operating Manual 19
20 Important notes 20 Operating Manual SX960 S1
21 3 Installation V CAUTION! Follow the safety instructions in chapter "Important notes" on page 15. The storage blade should not be subjected to any extreme environmental conditions (see section "Technical data" on page 12). Protect the storage blade from dust, humidity and heat. Make sure that the storage blade is acclimatized for the time indicated in this table before putting it into operation. Temperature difference ( C) Minimum acclimatization time (hours) Table 1: Acclimatization time In table "Acclimatization time", the temperature difference refers to the difference between the operating environment temperature and the temperature to which the storage blade was exposed previously (outside, transport or storage temperature). SX960 S1 Operating Manual 21
22 Installation 3.1 Installation procedure Unpacking a storage blade (see the next section on this page). Installing a storage blade in the system unit (see section "Installing/removing a storage blade in/from the system unit" on page 23). Putting a storage blade into operation (see section "Putting the storage blade into operation" on page 34 in the chapter "Installation and operation"). 3.2 Unpacking a storage blade V CAUTION! Follow the safety instructions in chapter "Important notes" on page 15. Do not unpack the storage blade until it is at its installation location. You should retain the original packaging of the storage blade for possible further transport. Transport the storage blade to the place where you want to set it up. Unpack all individual parts. Keep the original packaging in case you want to transport the storage blade again (applies only to EMEA market). Check the delivery for any damage during transport. Check whether the items delivered match the details on the delivery note. The product name and serial number of the product can be found on the ID card (see section "Indicators on the storage blade" on page 31). Notify your supplier immediately should you discover that the items delivered do not correspond to the delivery note. 22 Operating Manual SX960 S1
23 Installation 3.3 Installing/removing a storage blade in/from the system unit V CAUTION! Fitting rules Follow the safety instructions in chapter "Important notes" on page 15. A mix of SAS and SATA drives within the SX960 S1 storage blade is not allowed. A maximum of two SX960 S1 storage blades can be installed into a system unit (BX400 S1 and BX900 S1/BX900 S2). Only slots 2&3 and slots 6&7 or slots 4&5 of a BX400 S1 system unit can be fitted with SX960 S1 storage blades. They provide the server blade in the adjacent slot to the left with additional disk space (see figure 3). Slot: Option A: max. 2x SX960 Option B: Server Blade Storage Blade SX960 Figure 3: Fitting rules for the SX960 S1 storage blade within the BX400 S1 system unit SX960 S1 Operating Manual 23
24 Installation Only slots 7&8 and slots 15&16 of a BX900 S1/BX900 S2 system unit can be fitted with SX960 S1 storage blades. They provide the server blade in the adjacent slot to the left with additional disk space (see figure 4). Slot: Slot: Server Blade Storage Blade SX960 (max. 2x per system unit) Figure 4: Fitting rules for the SX960 S1 storage blade within the BX900 S1/BX900 S2 system unit Combinations of supported HDD/SSDs The table below shows the possible combinations of the drive types that can be installed. SATA BC SATA SAS SSD SATA Y Y N Y BC SATA Y Y Y Y SAS N Y Y Y SSD Y Y Y Y Y = supported N = not supported 24 Operating Manual SX960 S1
25 Installation Removing the dummy blades Any unused slots on the front of the system unit are fitted with appropriate dummy blades to comply with electromagnetic compatibility (EMC) regulations and to ensure sufficient cooling of the system components. The power supply unit slots on the back do not necessarily have to be populated. To add a SX960 S1 storage blade, you first have to remove two dummy blades from the relevant slots. Figure 5: Removing the dummy blades Push up the green release levers (see arrows) and pull the dummy blades out of their slots. SX960 S1 Operating Manual 25
26 Installation V CAUTION! Keep the dummy blade(s) for future use. If you remove a storage blade or a server blade and do not replace it with a new one, you must reinstall the dummy blade(s) due to cooling, to comply with EMC regulations, and to protect against fire. Installing the dummy blades Slide each dummy blade with the release lever down into the empty slot until it clicks into place. Installing the storage blade The SX960 S1 storage blade can be installed during operation and is recognized by the management blade. You must restart the related server blade to enable the storage blade to communicate with the server blade, see section "Putting the storage blade into operation" on page 34. V CAUTION! Follow the safety instructions and information in section "Electrostatic sensitive device label" on page 17. I Make sure the storage blade is installed the correct way round. The control panel must be in the area at the top. 26 Operating Manual SX960 S1
27 Installation Unlocking and installing the storage blade Figure 6: Unlocking the storage blade Undo the locking mechanism (1) of the release lever. Open the release lever (2). Push the storage blade as far as possible into the empty slot (3). SX960 S1 Operating Manual 27
28 Installation Figure 7: Locking the storage blade Push the release lever up until it clicks into place under the locking lever (1). 28 Operating Manual SX960 S1
29 Installation Removing the storage blade To remove the storage blade, you must first switch off the related server blade(s). Switch the server blade off: either using the On/Off button on the server blade or using the Web interface of the management blade (see the user interface description in the manual "ServerView Management Blade S1" for PRIMERGY BX400 Blade Server Systems respectively for PRIMERGY BX900 Blade Server Systems). Undo the locking mechanism of the release lever. Open the release lever. Pull the storage blade out of the slot. V CAUTION! If you have removed a storage blade and have not replaced it with a new one, you must install a dummy module in the empty slot. SX960 S1 Operating Manual 29
30 Installation 30 Operating Manual SX960 S1
31 4 Operation 4.1 Control and display elements Indicators on the storage blade Figure 8: Indicators on the storage blade 1 ID card You can pull out the ID card (see figure 8 above) as far as it will go and push it back in again. The ID card contains various system information, such as product name, serial number and order number. 2 Power indicator (green) Lights up: the left server blade is switched on Does not light: the left server blade is switched off SX960 S1 Operating Manual 31
32 Operation 3 ID indicator (blue) Lights up blue when the system has been selected by pressing the ID button (4). To deactivate, press the ID button again. The ID indicator can also be activated via the Management Blade Web interface and the ServerView Operations Manager and the irmc Web interface and its status is reported to the ServerView Operations Manager and the irmc. 4 ID button When the ID button is pressed, the ID indicator (3) lights up. 32 Operating Manual SX960 S1
33 Operation Indicators on the HDD/SSD module a b Figure 9: Indicators on the 2.5-inch HDD/SSD module 1 HDD/SSD BUSY (green) Lights up: HDD/SSD in active phase Does not light: HDD/SSD inactive (drive inactive) 2 HDD/SSD FAULT (orange) (in conjunction with a RAID controller) Does not light: no HDD/SSD error Lights up: HDD/SSD faulty or Rebuild stopped (drive defective, needs replacing, a rebuild process was stopped or the HDD/SSD module is not correctly inserted) Slow flashing: HDD/SSD Rebuild (the data is being restored after changing a drive) Fast flashing: HDD/SSD Identify SX960 S1 Operating Manual 33
34 Operation 4.2 Putting the storage blade into operation The SX960 S1 storage blade can be installed during operation and is recognized by the management blade. You must restart the related server blade to enable the storage blade to communicate with the server blade. Make sure that the storage blade is inserted correctly in the system unit (see section "Installing/removing a storage blade in/from the system unit" on page 23). There are two ways of restarting the server blade related to the storage blade: By pressing the On/Off button on the control panel of the server blade Via the Web interface of the management blade (see the user interface description in the manual "ServerView Management Blade S1" for PRIMERGY BX400 Blade Server Systems respectively for PRIMERGY BX900 Blade Server Systems). As soon as the related server blades are in operation, the storage blade's power indicator lights up green. After that, configure the drives of the storage blade with the ServerView RAID Manager. You will find further information in the "PRIMERGY ServerView Suite RAID Management" manual. 34 Operating Manual SX960 S1
35 5 Hot-plug components This chapter describes how to replace or add hot-plug components in the SX960 S1 storage blade. I The HDD/SSD modules are the only hot-plug components within the SX960 S1 storage blade. 5.1 Hot-plug drives The drives which can be ordered for the storage blade SX960 S1 are supplied already mounted in an installation frame so that defective drives can be replaced and new drives can be added during operation. The drive and installation frame together make up the HDD/SSD module. V CAUTION! The drive must not be removed from the installation frame by anyone except a service technician. SX960 S1 Operating Manual 35
36 Hot-plug components Figure 10: 2.5-inch HDD/SSD module and dummy module 1 Dummy module 2 Tabs for unlocking the dummy module 3 HDD/SSD module (installation frame with drive installed) 4 Indicators HDD/SSD Busy (green LED) and HDD/SSD Fault (orange LED). For a description, see table on page 33 in section "Indicators on the HDD/SSD module". 5 Handle for locking and unlocking the HDD/SSD module 6 Button for locking and unlocking the handle 7 Pit for applying a sticker with the current drive name Handling drives and HDD/SSD modules Drives incorporated in the HDD/SSD modules are highly sensitive electromagnetic devices and must be handled with great care. Incorrect handling can cause partial or total failure of the drives. These failures can result in data errors and to a loss of data or to total corruption of the drive. Observe the following rules to prevent such problems occurring: Only store and transport HDD/SSD modules within the limits stipulated in the specification. 36 Operating Manual SX960 S1
37 Hot-plug components When transporting HDD/SSD modules (even over short distances), always use the original packaging (ESD label). Never expose HDD/SSD modules to a temperature shock. Avoid the formation of condensation inside and on the outside of the drive. V CAUTION! The HDD/SSD module must be acclimatized in its operating environment for an acclimatization time before it is started up for the first time. Temperature difference ( C) (operating environment/ outside) Minimum acclimatization time (hours) Table 2: Acclimatization times for HDD/SSD modules Always set the HDD/SSD module down carefully, with the large surface facing downwards to prevent it from tipping over. 5.2 Removing/installing the dummy module Free slots are provided with dummy modules. Remove the dummy module before installing an additional HDD/SSD module. SX960 S1 Operating Manual 37
38 Hot-plug components Figure 11: Removing the dummy module Press both tabs on the dummy module together until the locking mechanism disengages (1). Pull the dummy module out of the slot (2). To install a dummy module, follow the same procedure in reverse order. V CAUTION! Store the dummy module in a safe place. If you have removed an HDD/SSD module and do not install a new one in its place, put the dummy module back in its place for cooling, to comply with EMC regulations (regulations regarding electromagnetic compatibility), and for protection against fire. Ensure that the dummy module engages correctly in the slot. 38 Operating Manual SX960 S1
39 Hot-plug components 5.3 Installing/removing the HDD/SSD module Unlocking the HDD/SSD module Figure 12: Unlocking the 2.5-inch HDD/SSD module Release the locking mechanism as follows: 1. Press the two green tabs of the locking lever together (1). 2. Pull the handle of the HDD/SSD module fully in the direction of the arrow (2). The HDD/SSD module is now unlocked. SX960 S1 Operating Manual 39
40 Hot-plug components Installing the HDD/SSD module Figure 13: Installing the HDD/SSD module Unlock the HDD/SSD module as described in section "Unlocking the HDD/SSD module" on page 39. Carefully push the HDD/SSD module into the empty mounting location (1) until it stops. Push the handle completely in the direction of the arrow (2) until the locking mechanism engages. Removing the HDD/SSD module V CAUTION! Replace an HDD/SSD module only while the system is powered on. Replacing an HDD/SSD module while the system is off would impact the RAID configuration at the next power up. 40 Operating Manual SX960 S1
41 Hot-plug components If you want to remove an HDD/SSD module during operation, proceed as follows: If you want to remove an HDD/SSD module that is not defective, the drive must be first set to offline via the software (RAID controller configuration software). Unlock the HDD/SSD module as described in section "Unlocking the HDD/SSD module" on page 39. Pull the HDD/SSD module out a few centimeters. Wait for at least 60 seconds. I This period is necessary for the RAID controller to recognize that an HDD/SSD module has been removed and for the drive to come to a stop. Pull the HDD/SSD module out completely. Install the new HDD/SSD module, as described in sections "Unlocking the HDD/SSD module" on page 39 and "Installing the HDD/SSD module" on page 40. V CAUTION! If you have removed an HDD/SSD module and do not install a new one in its place, put the dummy module back in its place for cooling, to comply with EMC regulations (regulations regarding electromagnetic compatibility), and for protection against fire. Ensure that the dummy module engages correctly in the slot. SX960 S1 Operating Manual 41
42 Hot-plug components 42 Operating Manual SX960 S1
43 6 Optional: Installation / Replacement of BBU / FBU Together with the controllers used with SX960 S1, a Battery Backup Unit (BBU) or a Flash Backup Unit (FBU) optionally can be installed (see following table). Product SX960 S1 S26361-K1382-V200 / S26361-K1382-V901 S26361-K1382-V202 / S26361-K1382-V902 S26361-K1382-V303 / S26361-K1382-V903 BBU Holder in SX960 BBU holder for ibbu07 fix mounted Common ibbu07/ ibbu08 holder C26361-K644- C942 FBU02 FBU holder C26361-K644- C970 ibbu/fbu Cable ibbu/fbu RAID Controller LTG ibbu 160 T26139-Y3987-V LTG ibbu 550 T26139-Y3987-V LTG ibbu 160 T26139-Y3987-V CBL FBU T26139-Y4032-V IBBU07 LI-ION LSZ:L S26361-F3257-E116 IBBU08 LI-ION LSZ:L S26361-F3257- E216 FBU02 LSZ:L S26361-F3669- E125 MEGARAID 2108 D2616 (Cougar II) S26361-D2616- A22-1-R S26361-F3554- E/L512 MEGARAID 2208 D3116 (Cougar III) S26361-D3116- C S26361-F3669- E/L4 Only for the Japanese market: SX960 S1 対 応 BBU 対 応 FBU 型 名 型 名 参 照 型 名 PY-S96AD1 PY-S96AD2 PYBBBR05A PYB-BBR04A BBU07 の 手 順 をご 確 認 く だ さ い 搭 載 で き ません PYBBBR03A BBU08 の 手 順 をご 確 認 く だ さ い PYBFBR02 PY-BBR01A BBU07 の 手 順 をご 確 認 く だ さ い (55cm のケーブルをご 使 用 く ださい ) PY-FBR01 SX960 S1 Operating Manual 43
44 Optional: Installation / Replacement of BBU / FBU 6.1 Installing the BBU07/ Preparations Remove the storage blade as described in section "Installing/removing a storage blade in/from the system unit" on page 29. Figure 14: Opening the storage blade Press down the touch point (1) and push the housing cover in the direction of the arrow as far as it will go (2). Lift off the housing cover. 44 Operating Manual SX960 S1
45 Optional: Installation / Replacement of BBU / FBU Removing the controller Figure 15: Removing the controller Remove both SAS cables from the controller (1 & 2). I Do not bend SAS cables! Remove the screw (3). Pull the controller out of the contact strip of the interposer board (4). Installation will be done in reverse order. SX960 S1 Operating Manual 45
46 Optional: Installation / Replacement of BBU / FBU Removing the interposer board Figure 16: Removing the interposer board Remove the power cable (1). Remove the cable from the control panel (2). Lift up both metal clips (3) as far as they will go. Remove the interposer board (4). Installation will be done in reverse order. 46 Operating Manual SX960 S1
47 Optional: Installation / Replacement of BBU / FBU Preparing the BBU07 Figure 17: Parts of the BBU07 kit Pos. Description 1 BBU (battery pack) with electronic parts underneath 2 BBU holder 3 Cable connecting BBU to controller SX960 S1 Operating Manual 47
48 Optional: Installation / Replacement of BBU / FBU Connecting the BBU cable to the BBU07 Figure 18: Connecting the BBU cable Plug the BBU cable in the connector on the BBU board (see pos. 1 in figure above). I The plug of the BBU cable has a number printed on the back. Make sure this side of the plug faces down, i.e. is not visible. Check whether the cable of the battery is connected to the BBU board (see pos. 2 in figure above). Inserting the BBU07 into the holder of BBU08 Proceed as described in section "Inserting the BBU08 into the holder" on page Operating Manual SX960 S1
49 Optional: Installation / Replacement of BBU / FBU Preparing the BBU08 The following figure shows all parts of the BBU08 kit: Figure 19: Parts of the BBU08 kit 1 Cable from BBU (battery pack) to controller 2 Holder for BBU (battery pack) with 3 keyhole slots for mounting purposes 3 BBU (battery pack) SX960 S1 Operating Manual 49
50 Optional: Installation / Replacement of BBU / FBU Connecting the BBU cable to the BBU08 Figure 20: Connecting the BBU cable Plug the BBU cable in the connector on the BBU08 (see figure). I The plug of the BBU cable is coded, i.e., it can only be plugged in correctly. 50 Operating Manual SX960 S1
51 Optional: Installation / Replacement of BBU / FBU Inserting the BBU08 into the holder Figure 21: Installing the BBU08 in the BBU08 holder (A) At a slight angle, fit the BBU08 under the upper retaining bracket (see frame) of the BBU holder as shown. Push on the BBU08 (see arrow in figure above) until it locks in place. Figure 22: Installing the BBU08 in the BBU08 holder (B) Ensure that the BBU08 is properly seated in the BBU holder as shown. SX960 S1 Operating Manual 51
52 Optional: Installation / Replacement of BBU / FBU Mounting the BBU07 I The BBU07 can be installed within two kinds of holder: BBU 07 holder (see figure 17 on page 47) BBU 08 holder (see figure 19 on page 49) Figure 23: Installation location of BBU07 The 3 shoulder screw caps (pos. #1 - #3) ensure that the BBU holder fits tightly. The eye (pos. #4) is needed to let the hook of the holder click into place (#4). 52 Operating Manual SX960 S1
53 Optional: Installation / Replacement of BBU / FBU Figure 24: Placing the BBU08 holder onto the shoulder screw caps Turn the BBU07 by 180 and place it with its keyhole slots on the 3 shoulder screw caps (see arrows #1 - #3)). Figure 25: Locking the BBU07 into place Push the BBU07 in the direction of the arrow until it snaps into place. SX960 S1 Operating Manual 53
54 Optional: Installation / Replacement of BBU / FBU Reinstalling the interposer board Figure 26: Reinstalling the interposer board Lift up both metal clips (1). Shift the interposer board into the marked openings (see circles) of the metal cage. Press on the metal clips to fix the interposer board (3). Reinstalling the controller Reinstall the controller. Follow the instructions on page 45 in reverse order. 54 Operating Manual SX960 S1
55 Optional: Installation / Replacement of BBU / FBU Connecting the BBU cable to the controller Figure 27: Connecting the BBU cable to the controller Connect the BBU cable to the BBU connector of the controller (see oval). SX960 S1 Operating Manual 55
56 Optional: Installation / Replacement of BBU / FBU Closing the storage blade Figure 28: Closing the storage blade Position the housing cover on the housing approx. 1-2 cm from the frame, so that it is level on both sides. Push the housing cover in the direction of the arrow until it clicks into place. Insert the storage blade in the system unit as described in section "Installing/removing a storage blade in/from the system unit" on page Operating Manual SX960 S1
57 Optional: Installation / Replacement of BBU / FBU Mounting the BBU08 The BBU holder is installed below the interposer board: Figure 29: Installation location of BBU08 The 3 shoulder screw caps (pos. #1 - #3) ensure that the BBU holder fits tightly. The eye (pos. #4) is needed to let the hook of the holder click into place (#4). SX960 S1 Operating Manual 57
58 Optional: Installation / Replacement of BBU / FBU Figure 30: Placing the BBU holder onto the shoulder screw caps Turn the BBU08 by 180 and place it with its keyhole slots on the 3 shoulder screw caps (see arrows #1 - #3)). Figure 31: Locking the BBU08 into place Push the BBU08 in the direction of the arrow until it snaps into place. 58 Operating Manual SX960 S1
59 Optional: Installation / Replacement of BBU / FBU Reinstalling the interposer board Proceed as described in section "Reinstalling the interposer board" on page 54. Reinstalling the controller Reinstall the controller. Follow the instructions on page 45 in reverse order. Connecting the BBU08 cable to the controller Figure 32: Connecting the BBU08 cable to the controller Connect the BBU08 cable to the BBU connector of the controller (see oval). Closing the storage blade Proceed as described in section "Closing the storage blade" on page 56. Insert the storage blade in the system unit as described in section "Installing/removing a storage blade in/from the system unit" on page 27. SX960 S1 Operating Manual 59
60 Optional: Installation / Replacement of BBU / FBU 6.2 Installing the FBU Preparations Remove the storage blade as described in section "Installing/removing a storage blade in/from the system unit" on page 29. Proceed as described in section Preparations. Removing the controller Proceed as described in section "Removing the controller" on page 45. Removing the interposer board Proceed as described in section "Removing the interposer board" on page Operating Manual SX960 S1
61 Optional: Installation / Replacement of BBU / FBU Preparing the FBU The following figure shows all parts of the FBU kit: Figure 33: All parts of the FBU kit 1 Holder for battery pack with 3 keyhole slots for mounting purposes 2 Battery pack 3 Adapter cable for connection with battery pack and controller SX960 S1 Operating Manual 61
62 Optional: Installation / Replacement of BBU / FBU Figure 34: Installing the FBU in the FBU holder (A) At a slight angle, fit the FBU (A3C ) under both retaining brackets of the FBU holder (C26361-K644-C970) as shown. Push in the FBU until it locks in place. Figure 35: Installing the FBU in the FBU holder (B) Ensure that the FBU is properly seated in the FBU holder as shown. 62 Operating Manual SX960 S1
63 Optional: Installation / Replacement of BBU / FBU Figure 36: Connecting the FBU adapter cable to the FBU Connect the cable end of the FBU module to the FBU adapter cable (T26139-Y4032-V1) as shown. SX960 S1 Operating Manual 63
64 Optional: Installation / Replacement of BBU / FBU Mounting the FBU The FBU holder is installed below the interposer board: Figure 37: Installation location of FBU08 The 3 shoulder screw caps (pos. #1 - #3) ensure that the FBU08 holder fits tightly. The eye (pos. #4) is needed to let the hook of the holder click into place (#4). 64 Operating Manual SX960 S1
65 Optional: Installation / Replacement of BBU / FBU Figure 38: Placing the FBU holder onto the shoulder screw caps Turn the FBU by 180 and place it with its keyhole slots on the 3 shoulder screw caps (see arrows #1 - #3)). Figure 39: Locking the FBU into place Push the FBU in the direction of the arrow until it snaps into place. SX960 S1 Operating Manual 65
66 Optional: Installation / Replacement of BBU / FBU Reinstalling the interposer board Proceed as described in section "Reinstalling the interposer board" on page 54. Reinstalling the controller Reinstall the controller. Follow the instructions on page 45 in reverse order. Connecting the FBU cable to the controller Figure 40: Connecting the FBU cable to the controller Connect the FBU cable to the FBU connector on the controller (see oval). Closing the storage blade Proceed as described in section "Closing the storage blade" on page 56 of chapter Installing the BBU07/08. Insert the storage blade in the system unit as described in section "Installing/removing a storage blade in/from the system unit" on page Operating Manual SX960 S1
67 Optional: Installation / Replacement of BBU / FBU 6.3 Replacing the BBU07/ Removing the BBU07/08 Remove the storage blade from the system unit as described in page 29. Open the storage blade as described on page 44. Figure 41: Removing the BBU07/08 Remove the BBU cable from the BBU connector of the controller (1). Lift up the locking hook (2). Shift the BBU in the direction of the arrow and out of the housing (3). SX960 S1 Operating Manual 67
68 Optional: Installation / Replacement of BBU / FBU Removing the BBU from its holder Figure 42: Installing the BBU in the BBU holder (A) Press against the lower retaining bracket (see frame) to open the holder wide enough for removing the BBU. Lift the BBU out of the holder (see arrow). Figure 43: Disconnecting the BBU cable Unplug the cable from the connector of the BBU (see arrow). 68 Operating Manual SX960 S1
69 Optional: Installation / Replacement of BBU / FBU Installing the BBU07/08 Plug the BBU cable into the connector on the new BBU07 (see figure 17 on page 48) respectively on the new BBU08 (see figure 20 on page 50). I The plug of the BBU cable is coded, i.e., it can only be plugged in correctly. Insert the new BBU07/08 into its holder (see "Inserting the BBU08 into the holder" on page 51). Install the new BBU07/08 into the housing (see "Mounting the BBU08" on page 57). Close the storage blade as described on page 56. Insert the storage blade in the system unit as described in section "Installing/removing a storage blade in/from the system unit" on page 27. SX960 S1 Operating Manual 69
70 Optional: Installation / Replacement of BBU / FBU 6.4 Replacing the FBU Removing the FBU Remove the storage blade from the system unit as described on page 29. Open the storage blade as described on page 44. Figure 44: Removing the FBU Remove the FBU cable from the FBU adapter cable (1). Lift up the locking hook (2). Shift the FBU in the direction of the arrow and out of the housing (3). 70 Operating Manual SX960 S1
71 Optional: Installation / Replacement of BBU / FBU Figure 45: Removing the FBU from the FBU holder At a slight angle, slide the FBU from under the retaining brackets of the FBU holder and remove it. SX960 S1 Operating Manual 71
72 Optional: Installation / Replacement of BBU / FBU Installing the FBU Insert the new FBU into its holder (see "Preparing the FBU" on page 61). Figure 46: Inserting the new FBU into its holder Connect the FBU cable to the adapter cable (1). Install the new FBU into the housing (see "Mounting the FBU" on page 64). Close the storage blade as described on page 56. Insert the storage blade in the system unit as described in section "Installing/removing a storage blade in/from the system unit" on page Operating Manual SX960 S1
73 7 Troubleshooting and tips V CAUTION! Follow the safety instructions in chapter "Important notes" on page 15. If the power-on indicator of the storage blade (see figure 8 on page 31) remains dark after you have switched on the related server blade, follow these instructions: All information on troubleshooting faults that may occur when operating server blades in the system unit are described in the operating manual for the corresponding system unit. If a fault occurs, try to correct it as described: in the chapter "Troubleshooting and tips" in the operating manual for your system unit, in the chapters for the installed components, in the documentation for the connected devices, in the help systems of the individual programs used. If you do not manage to correct the problem, proceed as follows: Make a note of the steps you have taken and the situation in which the fault occurred. Also make a note of the error messages displayed. Switch off the defective server blade or the system. Contact customer service. 7.1 Drives reported as "dead" when starting system RAID controller configuration incorrect Check and correct the settings for the drives using the RAID controller utility. Further information is provided in the manual for the RAID controller. SX960 S1 Operating Manual 73
74 Troubleshooting and tips 7.2 Added drive reported as defective RAID controller is not configured for this drive The drive was probably installed when the system was switched off. Reconfigure the RAID controller for the drive using the corresponding utility. Information is provided in the documentation for the RAID controller. or Remove and reinstall the drive while the system is switched ON. If the drive continues to be shown as defective, then replace it. 74 Operating Manual SX960 S1
PRIMERGY BX620 S6 Server Blade
Options Guide - English PRIMERGY BX620 S6 Server Blade Options Guide August 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your
PRIMERGY TX100 S1. Options Guide
PRIMERGY TX100 S1 Options Guide Edition August 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our
FUJITSU Server PRIMERGY RX1330 M2
Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX1330 M2 Upgrade and Maintenance Manual December 2015 Comments Suggestions Corrections The User Documentation Department would like to
PRIMERGY CX400 S2 Server Enclosure
Upgrade and Maintenance Manual - English PRIMERGY CX400 S2 Server Enclosure Upgrade and Maintenance Manual Edition December 2013 Comments Suggestions Corrections The User Documentation Department would
Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server
Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server High availability for lower expertise
Installation Guide. Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit. Issue: 022808 PN: 883884-07L Rev. A
Installation Guide Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit Issue: 022808 PN: 883884-07L Rev. A ii Copyright Notice 2008, Wyse Technology Inc. All rights reserved. This manual and the
PRIMERGY RX200 S8 Server
Upgrade and Maintenance Manual - English PRIMERGY RX200 S8 Server Upgrade and Maintenance Manual June 2015 Comments Suggestions Corrections The User Documentation Department would like to know your opinion
AXIS 291 1U Video Server Rack Installation Guide
AXIS 291 1U Video Server Rack Installation Guide About This Document This document describes how to install Axis blade video servers in the AXIS 291 1U Video Server Rack. Updated versions of this document
Power Supply Guide Version 1.0 for D-Show
Power Supply Guide Version 1.0 for D-Show Digidesign 2001 Junipero Serra Boulevard Daly City, CA 94014-3886 USA tel: 650 731 6300 fax: 650 731 6399 Technical Support (USA) tel: 650 731 6100 fax: 650 731
Options Guide - English PRIMERGY TX100 S2. Options Guide
Options Guide - English PRIMERGY TX100 S2 Options Guide July 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps
User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC)
User Guide - English FUJITSU Software ServerView Suite Local Service Panels Local Service Concept (LSC) Edition February 2013 Comments Suggestions Corrections The User Documentation Department would like
HP SuperSpeed USB 3.0 PCIe x1 Card. User Guide
HP SuperSpeed USB 3.0 PCIe x1 Card User Guide Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and Windows
Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE
Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards 1.2 PACKAGE
SoftRAID 5 QUICK START GUIDE. for OWC ThunderBay
SoftRAID 5 QUICK START GUIDE for OWC ThunderBay TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.2 FEATURES 1.3 ABOUT THIS MANUAL SYSTEM SETUP...2 2.1 GETTING STARTED 2.2 INITIALIZING,
Data Sheet Fujitsu PRIMERGY BX900 S1 Blade Server
Data Sheet Fujitsu PRIMERGY BX900 S1 Blade Server The Dynamic Cube Fujitsu PRIMERGY BX Blade Servers meet all the requirements of medium-sized companies as well as the branches and data centers of large
Aura SSD. for the 2013 Apple Mac Pro INSTALLATION GUIDE
Aura SSD for the 2013 Apple Mac Pro INSTALLATION GUIDE TABLE OF CONTENTS 1. INTRODUCTION...1 1.1 SYSTEM REQUIREMENTS 1.2 PACKAGE CONTENTS 1.3 ABOUT THIS MANUAL 2. INSTALLATION...2 2.1 PREPARING THE MAC
Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server
Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server Advanced Blade Ecosystem the ideal platform for branch offices and mediumsized companies Fujitsu PRIMERGY BX Blade Servers meet all the requirements of
HP SATA/SAS hard drive and Solid State Drive installation
HP SATA/SAS hard drive and Solid State Drive installation This document describes how to install Serial ATA (SATA) and Serial Attached SCSI (SAS) hard drives or Solid State Drives (SSD) in an internal
Fujitsu PRIMERGY BX600 S3 Blade Server
Datasheet Fujitsu PRIMERGY BX600 S3 Blade Server Advanced Blade Ecosystem - the ideal platform for branch offices and medium-sized companies The PRIMERGY BX Blade Servers are the ideal choice for the data
ADSL Modem Installation Guide. Model # 36R515 Part # 030-300108 Rev. D Revision Date 12/2000. ADSL Modem Installation Guide
ADSL Modem Installation Guide Model # 36R515 Part # 030-300108 Rev. D Revision Date 12/2000 ADSL Modem Installation Guide Installation Instructions Westell ADSL Modem 1. Package Inspection and Contents...2
How To Set Up An Ecm Display On A D210 (D210) (D2) (Ecm) (Emc) (Mcd) (Power Supply) (Mm) (Camellom) (Ios)
English Customer Display DM-D210 Installation Manual 401285101 CAUTIONS This document shall apply only to the product(s) identified herein. No part of this document may be reproduced, stored in a retrieval
PRIMERGY RX300 S6 Server
Service Supplement - english PRIMERGY RX300 S6 Server Service Supplement Edition March 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.
Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure
Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure Scale-Out Smart for HPC and Cloud Computing with enhanced energy efficiency The PRIMERGY CX400 Cloud extension servers are Fujitsu
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
Removable 2.5 SATA HDD Backup System
Removable 2.5 SATA HDD Backup System SAT2510U3REM SAT2510U3S *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario
Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001
Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
110244-003. PrintPAD CN3/4/3e/4e. User Guide
110244-003 PrintPAD CN3/4/3e/4e User Guide TABLE OF CONTENTS PrintPAD CN3/4 & PrintPAD CN3e/4e Printer Views...1 Open View...1 Closed View...1 Using Batteries: General Guidelines...1 Installing and/or
Compaq Presario Desktop Products. Upgrading and Servicing Guide
Compaq Presario Desktop Products Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to
2013 VTech Printed in China 91-009656-000 US
Rechargeable Power Pack User s Manual 2013 VTech Printed in China 91-009656-000 US INTRODUCTION The Rechargeable Power Pack makes it easier than ever to keep the InnoTab 3 or InnoTab 3S charged and ready
Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure
Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Scale-Out Smart for HPC, Cloud and Hyper-Converged Computing
QNAP RAID Expansion Enclosure Hardware User Manual. 2014. QNAP Systems, Inc. All Rights Reserved.
QNAP RAID Expansion Enclosure Hardware User Manual 2014. QNAP Systems, Inc. All Rights Reserved. Thank you for choosing QNAP products! This user manual provides descriptions of the hardware of the QNAP
MB169B+ USB Monitor. User Guide
MB169B+ USB Monitor User Guide Table of contents Notices... iii Safety information... iv Care & cleaning... v Takeback services... vi 1.1 Welcome!... 1-1 1.2 Package contents... 1-1 1.3 System requirement...
Small form factor bay converter and hard drive installation
Small form factor bay converter and hard drive installation HP xw6600 and HP xw8600 Workstations This document describes how to convert HP xw6600 and HP xw8600 Workstation 3.5-inch hard drive bays to hold
PCI Express USB 2.0 Adapter Card
PEXUSB400 Instruction Manual PCI Express USB 2.0 Adapter Card 4-Port (Independent) PCI Express to High Speed USB 2.0 Adapter Card FCC Compliance Statement This equipment has been tested and found to comply
PRIMERGY Econel 50 Server System
PRIMERGY PRIMERGY Econel 50 Server System Service Supplement Xenia Fierley Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: [email protected] Tel.: (089) 61001-157 Fax: 0 700
NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.
CAUTION: General Safety Instructions Use the following safety guidelines to help ensure your own personal safety and to help protect your equipment and working environment from potential damage. NOTE:
E&P HYDRAULICS Remote control EPRC-01 Level System Camper
USER S GUIDE E&P HYDRAULICS Remote control EPRC-01 Level System Camper 1 Copyright 2012, E&P Hydraulics This manual is copyrighted, with all rights reserved. Under the copyright laws, this may not, in
PRIMERGY RX100 S6 Server. Operating manual
PRIMERGY RX100 S6 Server Operating manual April 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our
IDE ATA/133 Controller
IDE ATA/133 Controller 2 Port PCI ATA-133 IDE Adapter Card PCIIDE2 Actual product may vary from photo FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class
SATA and SAS Hard Drive Backplane
SATSASBAY3BK Instruction Manual SATA and SAS Hard Drive Backplane 3 Drive 3.5 Removable SATA/SAS Mobile Rack Backplane FCC Compliance Statement This equipment has been tested and found to comply with the
Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server
Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server Blade Made Easy Fujitsu PRIMERGY BX Blade Servers provide a faster, simpler and lower-cost way to build and run an IT infrastructure in your midsize organization,
Scout 1U Rackmount Computer
Model Numbers ACC-CPU-RM- WIN7x64 ACC-CPU-RM-2008 Revision 5 Scout 1U Rackmount Computer Introduction The Scout 1U Rackmount Computer includes a solid state hard drive loaded with the Microsoft Windows
How To Buy An Fujitsu Primergy Bx400 S1 Blade Server
Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server BLADE MADE EASY - tailor-made for medium-sized companies Fujitsu PRIMERGY BX Blade Servers meet all the requirements of medium-sized companies as well
Antenna Splitter ASA 1. Instruction manual
Antenna Splitter ASA 1 Instruction manual Contents Important safety instructions... 2 The ASA 1 active antenna splitter... 4 Delivery includes... 4 Operating elements... 5 Putting the ASA 1 into operation...
Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 www.akitio.
Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.akitio.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...
Dual msata SSD to 2.5in SATA SSD Converter with RAID
Dual msata SSD to 2.5in SATA SSD Converter with RAID 25SAT22MSAT *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del
7 High-Resolution Digital Photo Frame
TM 16-1003 User s Guide 7 High-Resolution Digital Photo Frame One demo photo included, as illustrated Please read this user s guide before using your new photo frame. Package contents Photo Frame AC Adapter
Bluetooth Stereo Headphone. User Guide. Hive
Bluetooth Stereo Headphone User Guide Hive 1. Product Description Avantree Hive is a Bluetooth stereo headphone with MIC from the Avantree family. It delivers clear voice transmission and high quality
Dual M.2 NGFF SATA RAID Adapter
Dual M.2 NGFF SATA RAID Adapter 25S22M2NGFFR *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario - es.startech.com
Cisco TelePresence MCU 4500 Series safety and compliance information
Cisco TelePresence MCU 4500 Series safety and compliance information On this page: Safety information symbols Operating guidelines Safety warnings Technical specifications Compliance information WEEE information
Upgrading and Servicing Guide
Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed
Model 70A00-1. GSM Cellular Communications Center
Home Automation, Inc. Model 70A00-1 GSM Cellular Communications Center Operation Manual Document Number 70I00-1 Rev A August, 2009 Contents Description... 1 Use with security systems...1 Everyday use...2
StructureScan HD Module. Installation Guide ENGLISH. www.bandg.com www.simrad-yachting.com www.lowrance.com
StructureScan HD Module Installation Guide ENGLISH www.bandg.com www.simrad-yachting.com www.lowrance.com Disclaimer As Navico is continuously improving this product, we retain the right to make changes
NFC Communication Tray Model: HHX-IT3-Z
INSTRUCTION MANUAL NFC Communication Tray Model: HHX-IT3-Z ENGLISH CONTENTS Introduction...3 Important safety information...4 Know your unit...6 Transferring data to the PC...7 Care and maintenance...8
USB to IDE or SATA Adapter
USB to IDE or SATA Adapter USB 2.0 to IDE or SATA Adapter Cable USB2SATAIDE Instruction Manual Actual product may vary from photo FCC Compliance Statement This equipment has been tested and found to comply
READ FIRST! Universal Car/Air Adapter User Manual
AutoAir Manual 1/9/03 2:03 PM Page 1 READ FIRST! Universal Car/Air Adapter User Manual Congratulations! Your new Kensington Universal Car/Air Adapter is a highly efficient Universal Car/Air Adapter for
StorTrends 3400 Hardware Guide for Onsite Support
StorTrends 3400 Hardware Guide for Onsite Support MAN-3400-SS 11/21/2012 Copyright 1985-2012 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200
2 Bay USB 3.0 RAID 3.5in HDD Enclosure
2 Bay USB 3.0 RAID 3.5in HDD Enclosure SAT3520U3SR *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario - es.startech.com
M.2 NGFF SSD to 2.5in SATA Adapter
M.2 NGFF SSD to 2.5in SATA Adapter SAT2M2NGFF25 *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario - es.startech.com
FCC COMPLIANCE STATEMENT FOR AMERICAN USERS
FCC COMPLIANCE STATEMENT FOR AMERICAN USERS This equipment has been tested and found to comply with the limits for a CLASS A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
Serial ATA Hard Drive Enclosure
SAT2510U2E SAT2510BU2E Instruction Manual Serial ATA Hard Drive Enclosure 2.5 esata/usb External Hard Drive Enclosure for Serial ATA Hard Drives FCC Compliance Statement This equipment has been tested
Wireless Optical Mouse
Wireless Optical Mouse User s Manual Model PD950P FCC STATEMENT PD950P This device complies with part 15 of FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause
HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in
HP Pavilion All-in-One MS200 series PC *579907-001* *579907-001* Printed in Upgrading and Servicing Guide Replacing a Wireless Keyboard or Mouse...2 Before You Begin... 2 Replacing the Keyboard or Mouse...
ARCHOS (www.archos.com/support).
1 ! www.archos.com/register, ARCHOS.. ARCHOS, (www.archos.com/register).. ARCHOS (www.archos.com/support)., Windows, Windows Help Start ( ), Help and Support.. ARCHOS. 2 ,.! /, : ARCHOS 9,,,,,. -.,. ARCHOS
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
INSTALLATION GUIDE ConnectLine TV Adapter Getting started
INSTALLATION GUIDE ConnectLine TV Adapter Getting started PURPOSE OF THIS GUIDE READ THIS FIRST Before your hearing instruments can receive sound from the TV, the adapter must be connected to the TV and
PCI Express USB 3.0 Controller Adapter Card
PEXUSB3S2 Instruction Manual PCI Express USB 3.0 Controller Adapter Card 2-Port PCI Express SuperSpeed USB 3.0 Controller Adapter Card FCC Compliance Statement This equipment has been tested and found
Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!
BeoLab 6002 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equip ment to dripping or splashing and ensure that no objects
RocketStor SMART RAID
RocketStor SMART RAID User Guide v1.0 1 Copyright HighPoint Technologies Inc., 1995-2012. All rights reserved. OS X and Macintosh are registered trademarks of Apple Corporation. All other trademarks and
4 Drive esata USB FireWire External SATA RAID Enclosure
4 Drive esata USB FireWire External SATA RAID Enclosure S354UFER *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del
2 Port PCI Express SATA 6Gbps Controller - 1x esata + 1x SATA
2 Port PCI Express SATA 6Gbps Controller - 1x esata + 1x SATA PEXSAT31E1 *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES:
PROGRAMMER INSTALLATION INSTRUCTIONS
PROGRAMMER INSTALLATION INSTRUCTIONS TABLE OF CONTENTS Description 4 Installation 4 Operation 5 Safety Precautions 6 Regulatory & Service Information 6 Important Safety and Usage Information 7 Regulatory
PRIMERGY TX100 S3 Server
Upgrade and Maintenance Manual - English PRIMERGY TX100 S3 Server Upgrade and Maintenance Manual February 2014 Comments Suggestions Corrections The User Documentation Department would like to know your
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall
BOSE. Link AL8 HOMEWIDE WIRELESS AUDIO LINK
BOSE Link AL8 HOMEWIDE WIRELESS AUDIO LINK Français English SAFETY INFORMATION Please read this owner s guide Please take the time to follow the instructions in this owner s guide carefully. It will help
Manual. Simrad StructureScan LSS-1 Sonar Module. English
Manual Simrad StructureScan LSS-1 Sonar Module English www.simrad-yachting.com A brand by Navico - Leader in Marine Electronics Disclaimer As Navico is continuously improving this product, we retain the
3.5 External Hard Drive Enclosure
UNI3510U2E / UNI3510U2EGB UNI3510U2EB / UNI3510UEBGB Instruction Manual 3.5 External Hard Drive Enclosure 3.5 esata/usb 2.0 to IDE/SATA External Hard Drive Enclosure with One-Touch Backup FCC Compliance
Wave/PC Interactive System USB Adapter Kit. Installation Guide
Wave/PC Interactive System USB Adapter Kit Installation Guide Safety Information 1. Read these instructions for all components before using this product. 2. Keep these instructions for future reference.
USER GUIDE. Access to the Server is via the following webpage: www.admin.airgoosignage.co.uk
USER GUIDE The A+K Airgoo Digital Signage MicroPlayer is a totally new generation of product with wireless capabilities and innovative features. It is designed to operate with our Digital Signage Server
USB 3.0/eSATA Dual 2.5/3.5 SATA HDD Dock with UASP
USB 3.0/eSATA Dual 2.5/3.5 SATA HDD Dock with UASP SDOCK2U33EB *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario
3.5 USB 3.0 to SATA III HDD Enclosure with UASP Support
3.5 USB 3.0 to SATA III HDD Enclosure with UASP Support S3510BMU33 S3510SMU33 *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com
PRIMERGY RX200 S6 Server
Options Guide - English PRIMERGY RX200 S6 Server Options Guide Edition November 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your
Digital Satellite Receiver
USER GUIDE Digital Satellite Receiver Models DSR207, DSR317, DSR505, and DSR530 CONTENTS IMPORTANT SAFETY INSTRUCTIONS...1 DSR BASICS SYMBOLS/ICONS...6 Front Panel...6 Back Panel...7 CONNECTING YOUR DSR...10
Wireless Indoor/ Outdoor Thermometer
Wireless Indoor/ Outdoor Thermometer Owner s Manual Please read before using this equipment. ˆ Contents FCC Information... 3 FCC Declaration of Conformity... 5 Preparation... 5 Installing Batteries...
User Guide Microsoft Screen Sharing for Lumia Phones (HD-10)
User Guide Microsoft Screen Sharing for Lumia Phones (HD-10) Issue 1.1 EN-US User Guide Microsoft Screen Sharing for Lumia Phones (HD-10) Contents Safety 3 About your accessory 4 Keys and parts 5 Connect
Key. ➍ Micro USB Port ➎ Operating System Toggle Keys ➏ Foam Screen Protectors. ➊ On/Off switch ➋ Bluetooth Connect Button (flashes when searching)
INSTRUCTION MANUAL ➏ ➋ ➊ Product Features ➎ ➍ ➌ Built-in wireless Bluetooth 3.0 keyboard Compatible across ios, Android, and Windows, enabling you to mix and match with devices Ultra-thin, lightweight
Beckhoff onboard SATA-RAID
Installation and operating instructions for Beckhoff onboard SATA-RAID Version: 1.3 Date: 2009-07-24 Table of contents Table of contents 1. 2. 3. 4. 5. 6. 7. General notes 2 Notes on the documentation
PRIMERGY RX600 S6 Server
Operating Manual - English PRIMERGY RX600 S6 Server Operating Manual July 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback
HP 22-in-1 Media Card Reader
HP 22-in-1 Media Card Reader Introduction This document describes how to install the HP 22-in-1 Media Card Reader into an HP Workstations adapter bracket, and then install the media card reader and bracket
User Guide Nokia Portable Wireless Charging Plate DC-50
User Guide Nokia Portable Wireless Charging Plate DC-50 Issue 1.1 EN User Guide Nokia Portable Wireless Charging Plate DC-50 Contents For your safety 3 About your accessory 4 Keys and parts 5 Top up your
USB 3.0 to M.2 NGFF SSD Enclosure with UASP
USB 3.0 to M.2 NGFF SSD Enclosure with UASP SM2NGFFMBU33 *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario
Pad. Quick Start Guide
Pad Quick Start Guide Copyright 2008 Mimio Congratulations on your mimio Pad purchase! mimio Pad is a 4 GHz wireless pad. To configure mimio Pad for use, install the mimio Studio software and plug the
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
HP Personal Media Drive User s Guide
HP Personal Media Drive User s Guide The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be
2.5/3.5 SATA HDD Docking Station
SATADOCKU2 SATADOCKU2E SATADOCK22UE 2.5/3.5 SATA HDD Docking Station FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
aseries A13B Mini Bullet Camera User Manual
aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView
USB 3.0 SATA/IDE 2.5 Hard Drive Enclosure
USB 3.0 SATA/IDE 2.5 Hard Drive Enclosure UNI251BMU33 *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario -
2GB MP3 Player USER GUIDE
DO NOT FORMAT UNIT under FAT. 2GB MP3 Player USER GUIDE Jazwares, Inc. 2010 CONTENTS Please read the instructions along with the MP3 Player carefully before you use it, so that you can operate it conveniently.
USB Mini Print Server PS121. Installation Guide
USB Mini Print Server PS121 Installation Guide Introduction Thank you for purchasing a NETGEAR PS121 USB Mini Print Server. With this print server you can share your printer with all the computers in your