PRIMERGY CX400 S2 Server Enclosure

Size: px
Start display at page:

Download "PRIMERGY CX400 S2 Server Enclosure"

Transcription

1 Upgrade and Maintenance Manual - English PRIMERGY CX400 S2 Server Enclosure Upgrade and Maintenance Manual Edition December 2013

2 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by to Certified documentation according to DIN EN ISO 9001:2008 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2008. cognitas. Gesellschaft für Technik-Dokumentation mbh Copyright and Trademarks Copyright 2013 Fujitsu Technology Solutions GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers. The contents of this manual may be revised without prior notice. Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. No part of this manual may be reproduced in any form without the prior written permission of Fujitsu. Microsoft, Windows, Windows Server, and Hyper V are trademarks or registered trademarks of Microsoft Corporation in the USA and other countries. Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the USA and other countries.

3 Before reading this manual For your safety This manual contains important information for safely and correctly using this product. Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure these safety notes are understood before using the product. Keep this manual and the manual "Safety Notes and Regulations" in a safe place for easy reference while using this product. Radio interference This product is a "Class A" ITE (Information Technology Equipment). In a domestic environment this product may cause radio interference, in which case the user may be required to take appropriate measures. VCCI-A Aluminum electrolytic capacitors The aluminum electrolytic capacitors used in the product's printed circuit board assemblies and in the mouse and keyboard are limited-life components. Use of these components beyond their operating life may result in electrolyte leakage or depletion, potentially causing emission of foul odor or smoke. As a guideline, in a normal office environment (25 C) operating life is not expected to be reached within the maintenance support period (5 years). However, operating life may be reached more quickly if, for example, the product is used in a hot environment. The customer shall bear the cost of replacing replaceable components which have exceeded their operating life. Note that these are only guidelines, and do not constitute a guarantee of trouble-free operation during the maintenance support period. High safety use This product has been designed and manufactured to be used in commercial and/or industrial areas as a server. When used as visual display workplace, it must not be placed in the direct field of view to avoid incommoding reflections (applies only to TX server systems). The device has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk of life or body if such safety cannot be assured. CX400 S2 Upgrade and Maintenance Manual

4 These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, air traffic control, traffic control in mass transport systems, medical devices for life support, and missile guidance control in weapons systems (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use. Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused by lightning. To prevent a momentary voltage drop, use of an AC uninterruptible power supply is recommended. (This notice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA, the Japan Electronics and Information Technology Industries Association.) Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan. Documents which contain such technology should not be exported from Japan or transferred to non-residents of Japan without first obtaining authorization in accordance with the above law. Harmonic Current Standards This product conforms to harmonic current standard JIS C Only for the Japanese market: About SATA hard disk drives The SATA version of this server supports hard disk drives with SATA / BC-SATA storage interfaces. Please note that the usage and operation conditions differ depending on the type of hard disk drive used. Please refer to the following internet address for further information on the usage and operation conditions of each available type of hard disk drive: Upgrade and Maintenance Manual CX400 S2

5 Content 1 Introduction Where to find which information? Notational conventions Before you start Classification of procedures Customer Replaceable Units (CRU) Field Replaceable Units (FRU) Average task duration Tools you need at hand For the 2.5-inch chassis For the 3.5-inch chassis Documents you need at hand Documents for the server enclosure Documents for the server nodes Important information Safety instructions CE conformity FCC Class A Compliance Statement Environmental protection Basic hardware procedures Shutting down the server node Disconnecting the power cord Removing the server enclosure out of the rack Preliminary steps Removing the rear fixing brackets CX400 S2 Upgrade and Maintenance Manual

6 Content Removing the server enclosure out of the rack Removing the server node from the server enclosure Removing the server node CX250 S Removing the server node CX270 S Removing the server node dummy module Opening the server enclosure inch chassis Removing the top cover Removing the top cover inch chassis Removing the top cover Removing the power distribution module Installing the power distribution module Closing the server enclosure inch chassis Installing the top cover Installing the top cover inch chassis Installing the top cover Installing the server node dummy module Installing the server node in the server enclosure Basic information Installing server node CX250 S Installing server node CX270 S Mounting the server enclosure in the rack Seating the server on the rack rails Installing the rail kit cage nut Connecting the power cord Switching on the server node(s) Basic software procedures Starting the maintenance task Switching on the ID indicator Completing the maintenance task Switching off the ID indicator Upgrade and Maintenance Manual CX400 S2

7 Content Performing a RAID array rebuild Using the Chassis ID Prom Tool Power supply Basic information General equipping rules Installing the power supply module Required tools Removing the dummy cover Installing the power supply module Concluding steps Removing the power supply module Required tools Preliminary steps Installing the dummy cover Replacing the power supply module Required tools Preliminary steps Removing the defective power supply module Installing the new power supply module Concluding steps Replacing the power distribution board Replacing the defective top PDB Required tools Preliminary steps Removing the top PDB Installing the top PDB Concluding steps Replacing the defective bottom PDB Required tools Preliminary steps Removing the bottom PDB Installing the bottom PDB Concluding steps CX400 S2 Upgrade and Maintenance Manual

8 Content 7 Hard disk drives / solid state drives Basic information General equipping rules inch hard disk drives / solid state drives HDD/SSD install order in the 2.5-inch chassis Configuration with standard CPU Configuration with 130 W (6 core) or 130 W (4 core) CPU support Installing 2.5-inch HDD/SSD modules Required tools Preliminary steps Removing a 2.5-inch HDD/SSD tray Installing a 2.5-inch HDD/SSD module Concluding steps Removing 2.5-inch HDD/SSD modules Required tools Preliminary steps Removing a 2.5-inch HDD/SSD module Installing a 2.5-inch HDD/SSD tray Replacing a 2.5-inch HDD/SSD module Required tools Preliminary steps Removing a 2.5-inch HDD/SSD module Installing a 2.5-inch HDD/SSD module Concluding steps inch hard disk drives HDD install order in the 3.5-inch chassis Configuration with standard CPU Configuration with 130 W (6 core) or 130 W (4 core) CPU support Installing 3.5-inch HDD modules Required tools Preliminary steps Removing a 3.5-inch HDD tray Installing a 3.5-inch HDD module Concluding steps Removing 3.5-inch HDD modules Required tools Preliminary steps Removing a 3.5-inch HDD module Upgrade and Maintenance Manual CX400 S2

9 Content Installing a 3.5-inch HDD tray Replacing a 3.5-inch HDD module Required tools Preliminary steps Removing a 3.5-inch HDD module Installing a 3.5-inch HDD module Concluding steps Replacing HDD/SSD SAS/SATA backplanes Replacing the 2.5-inch HDD/SSD SAS/SATA backplane Required tools Preliminary steps Adhere plastic film to the 2.5-inch HDD SAS/SATA backplane Removing the 2.5-inch HDD SAS/SATA backplane Installing the 2.5-inch HDD SAS/SATA backplane Concluding steps Replacing the 3.5-inch HDD SAS/SATA backplane Required tools Preliminary steps Adhere plastic film to the 3.5-inch HDD SAS/SATA backplane Removing the 3.5-inch HDD SAS / SATA backplane Installing the 3.5-inch HDD SAS/SATA backplane Concluding steps System fan Basic Information Replacing the fan in the fan module Required tools Preliminary steps Removing the fan module Removing the fan from the fan holder Installing fan1 and fan Installing the fan Installing the fan Installing fan3 and fan Installing the fan Installing the fan CX400 S2 Upgrade and Maintenance Manual

10 Content Installing the fan module Concluding steps Midplane Replacing the midplane Required tools Preliminary steps Removing the midplane Installing the midplane Concluding steps Linking boards Linking boards in 2.5-inch HDD chassis Basic Information Replacing the linking board Required tools Preliminary steps Removing the linking board Installing the linking board Concluding steps Linking boards in 3.5-inch HDD chassis Basic information Replacing the linking board Required tools Preliminary steps Removing the linking board Installing the linking board Concluding steps Front panel Replacing the front panel board Required tools Preliminary steps Removing the front ear bracket Removing the front panel board Installing the front panel board Upgrade and Maintenance Manual CX400 S2

11 Content Installing the front ear bracket Concluding steps Replacing the front panel cable Required tools Preliminary steps Removing the front panel cable Installing the front panel cable Routing of the front panel cable Concluding steps Cabling Cabling overview Cabling Connectors on the boards Appendix Mechanical overview Multi-node server system front 2.5 inch HDD/SSD model Multi-node server system front 3.5 inch HDD model Multi-node server system rear CX400 S2 server enclosure with CX250 S2 server nodes CX400 S2 server enclosure with CX270 S2 server nodes Multi-node server system interior inch HDD/SSD model inch HDD model Controls and indicators Front panel Controls on the front panel Indicators on the front panel Hard disk drives Indicators on the hard disk drives Power supply module Indicator on hot-plug power supply module CX400 S2 Upgrade and Maintenance Manual

12 Content Server nodes Minimum startup configuration Upgrade and Maintenance Manual CX400 S2

13 Version history Issue number Reason for update 1.0 / September 2013 Initial release 2.0/ December 2013 Chapter , CX400 S2 Upgrade and Maintenance Manual 13

14 Version history 14 Upgrade and Maintenance Manual CX400 S2

15 1 Introduction This Upgrade and Maintenance Manual provides instructions for the following procedures: Upgrading the server configuration by adding optional hardware components Upgrading the server configuration by replacing existing hardware components with superior ones. Replacing defective hardware components This manual focuses on on-site maintenance tasks. It is recommended to prepare each service assignment following remote diagnostics procedures, as described in the "ServerView Suite Local Service Concept (LSC)" manual (see section "Documents you need at hand" on page 27. V CAUTION! The document at hand comprises procedures of a wide range of complexity. Check the profile of qualification for technicians before assigning tasks. Before you start, carefully read "Classification of procedures" on page 21. CX400 S2 Upgrade and Maintenance Manual 15

16 Introduction 1.1 Where to find which information? While the Upgrade and Maintenance Manual focuses on upgrade and maintenance procedures to bring the server back to normal operation, additional manuals provide detailed background information on server components and BIOS settings. For information on documents you need to have with you when leaving for maintaining a server see "Documents you need at hand" on page 27. I All documentation on PRIMERGY hardware and ServerView software is available online from the Fujitsu manuals server at: (global market) (Japanese market) The complete PRIMERGY documentation set can also be downloaded as a DVD ISO image at: ftp://ftp.ts.fujitsu.com/images/serverview/manuals (global market) (Japanese market) 16 Upgrade and Maintenance Manual CX400 S2

17 Introduction 1.2 Notational conventions The following notational conventions are used in this manual: Text in italics fixed font semi-bold fixed font "Quotation marks" [Abc] V CAUTION! I indicates commands or menu items indicates system output indicates text to be entered by the user indicate names of chapters and terms that are being emphasized describes activities that must be performed in the order shown indicates keys on the keyboard Pay particular attention to texts marked with this symbol! Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data. indicates additional information, notes and tips indicates the procedure category in terms of complexity and qualification requirements, see "Classification of procedures" on page 21 indicates the average task duration, see "Average task duration" on page 23 CX400 S2 Upgrade and Maintenance Manual 17

18 Introduction 18 Upgrade and Maintenance Manual CX400 S2

19 2 Before you start Before you start any upgrade or maintenance task, please proceed as follows: Carefully read the safety instructions in chapter "Important information" on page 31. Make sure that all necessary manuals are available. Refer to the documentation overview in section "Documents you need at hand" on page 27. Print the PDF files if required. Make yourself familiar with the procedure categories introduced in section "Classification of procedures" on page 21. Ensure that all required tools are available according to section "Tools you need at hand" on page 24. Installing optional components The "PRIMERGY CX400 S2 Server Enclosure Operating Manual" gives an introduction to server features and provides an overview of available hardware options. Use the Fujitsu ServerView Suite management software to prepare hardware expansions. ServerView Suite documentation is available online at ( for the Japanese market). Please refer to the following ServerView Suite topics: Operation Tools for Service & Diagnostics Virtualization I For the latest information on hardware options, refer to your server s hardware configurator available online at the following address: for the EMEA market: for the Japanese market: CX400 S2 Upgrade and Maintenance Manual 19

20 Before you start Please contact your local Fujitsu customer service partner for details on how to order expansion kits or spare parts. Use the Fujitsu Illustrated Spares Catalog to identify the required spare part and obtain technical data and order information. Illustrated Spares catalogs are available online at (EMEA market only). 20 Upgrade and Maintenance Manual CX400 S2

21 Before you start 2.1 Classification of procedures The complexity of maintenance procedures varies significantly. Procedures have been assigned to one of three unit categories, indicating the level of difficulty and required qualification. At the beginning of each procedure, the involved unit type is indicated by one of the symbols introduced in this section. I Please ask your local Fujitsu service center for more detailed information Customer Replaceable Units (CRU) Customer Replaceable Units (CRU) Customer Replaceable Units are intended for customer self service and may be installed or replaced as hot-plug components during operation. I Components that the customer is entitled to replace may differ according to the service form in his country. Hot-plug components increase system availability and guarantee a high degree of data integrity and fail-safe performance. Procedures can be carried out without shutting down the server or going offline. Components that are handled as Customer Replaceable Units Hot-plug power supply units Hot-plug HDD / SSD modules Peripherals that are handled as Customer Replaceable Units Keyboard Mouse CX400 S2 Upgrade and Maintenance Manual 21

22 Before you start Field Replaceable Units (FRU) Field Replaceable Units (FRU) Removing and installing Field Replaceable Units involves complex maintenance procedures on integral server components. Procedures will require shutting down, opening and disassembling the server. V CAUTION! Maintenance procedures involving Field Replaceable Units must be performed exclusively by Fujitsu service personnel or technicians trained by Fujitsu. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability. Components that are handled as Field Replaceable Units Non hot-plug fans SAS / SATA backplanes Power backplane / power distribution board Front panel I Please ask your local Fujitsu service center for more detailed information. 22 Upgrade and Maintenance Manual CX400 S2

23 Before you start 2.2 Average task duration Average task duration: 10 minutes The average task duration including preliminary and concluding steps is indicated at the beginning of each procedure next to the procedure class. Refer to table 1 on page 23 for an overview of steps taken into account for calculating the average task duration: Step included Explanation Server shutdown no Shutdown time depends on hardware and software configuration and may vary significantly. Software tasks necessary before maintenance are described in section "Starting the maintenance task" on page 77". Rack removal, disassembly Transport Maintenance procedures Transport Assembly, rack installation Starting up yes no yes no yes no Table 1: Calculation of the average task duration Making the server available, removing the server from the rack (if applicable) Transporting the server to the service table (where required) depends on local customer conditions. Maintenance procedures including preliminary and concluding software tasks Returning the server to its installation site (where required) depends on local customer conditions. Reassembling the server, installing the server in the rack (if applicable) Booting time depends on hardware and software configuration and may vary significantly. CX400 S2 Upgrade and Maintenance Manual 23

24 Before you start 2.3 Tools you need at hand When preparing the maintenance task, ensure that all required tools are available according to the overview below. You will find a list of required tools at the beginning of each procedure For the 2.5-inch chassis Screw driver / Bit insert Screw Usage Type Phillips PH2 / (+) No. 2 hexagonal cross SW5 / PZ2 Phillips PH2 / (+) No. 2 hexagonal cross SW5 / PZ2 Chassis Chassis, HDD backplane, PDB boards 6-32 x 5.0 mm MS06050FD x 4.7 mm MU0603EHDD1 Phillips PH2 / (+) No. 2 hexagonal cross SW5 / PZ2 Chassis 6-32 x 3.5 mm MS06025FD10 Phillips PH2 / (+) No. 2 hexagonal cross SW5 / PZ2 Chassis 6-32 x 4.0 mm MS06010I000 Phillips PH1 / (+) No. 1 HDD tray M3 x 4.0 mm MS30040FD30 Table 2: List of required tools and used screws for the 2.5-inch chassis 24 Upgrade and Maintenance Manual CX400 S2

25 Before you start Screw driver / Bit insert Screw Usage Type Phillips PH2 / (+) No. 2 Midplane 6-32 x 5.5 mm MU06055BCI0 Phillips PH2 / (+) No. 2 Front panel 6-32 x 5.0 mm MU06050IBJ1 Phillips PH2 / (+) No. 2 system fans M5 x 10 mm MS50100I010 Table 2: List of required tools and used screws for the 2.5-inch chassis CX400 S2 Upgrade and Maintenance Manual 25

26 Before you start For the 3.5-inch chassis Screw driver / Bit insert Screw Usage Type Phillips PH1 / (+) No. 1 Chassis M3 x 3.0 mm MS30030FEL0 Phillips PH2 / (+) No. 2 hexagonal cross SW5 / PZ2 Phillips PH2 / (+) No. 2 hexagonal cross SW5 / PZ2 Chassis, HDD tray Chassis, HDD backplane, PDB boards 6-32 x 5.0 mm MS06050FD x 4.7 mm MU0603EHDD1 Phillips PH2 / (+) No. 2 hexagonal cross SW5 / PZ2 Chassis 6-32 x 3.5 mm MS06025FD10 Phillips PH2 / (+) No. 2 hexagonal cross SW5 / PZ2 Chassis 6-32 x 4.0 mm MS06010I000 Phillips PH2 / (+) No. 2 Midplane MU06055BCI x 5.5 mm Table 3: List of required tools and used screws for the 3.5-inch chassis 26 Upgrade and Maintenance Manual CX400 S2

27 Before you start Screw driver / Bit insert Screw Usage Type Phillips PH2 / (+) No. 2 Front panel 6-32 x 5.0 mmmu06050ibj1 Phillips PH2 / (+) No. 2 system fans M5 x 10 mm MS50100I010 Table 3: List of required tools and used screws for the 3.5-inch chassis 2.4 Documents you need at hand Maintenance procedures may include references to additional documentation. When preparing the maintenance task, ensure that all required manuals are available according to the overview below. I Ensure to store all printed manuals enclosed with your server in a save place for future reference. Unless stated otherwise, all manuals are available online at under Industry standard servers. For the Japanese market please use the following address: CX400 S2 Upgrade and Maintenance Manual 27

28 Before you start Documents for the server enclosure Document "ServerView Quick Start Guide" "Safety notes and regulations" manual " 安 全 上 のご 注 意 " for the Japanese market "PRIMERGY CX400 S2 Server Enclosure Operating Manual" System board and service labels Software documentation Illustrated Spares catalog Glossary "Warranty" manual " 保 証 書 " for the Japanese market "Returning used devices" manual "Service Desk" leaflet " サポート&サービス " for the Japanese market Description Information on initial server setup and software configuration, available online Important safety information, available online or as a printed copy Available online Labels inside the side / top server cover outlining connectors, indicators and basic maintenance tasks "ServerView Suite Local Service Concept (LSC)" user guide "ServerView Operations Manager - Server Management" user guide Spare parts identification and information system (EMEA market only), available for online use or download (Windows OS) at or from the CSS component view of the ServerView Operations Manager Available online Important information on warranty regulations, recycling and service, available online or as a printed copy Recycling and contact information, available online or as a printed copy Table 4: Documentation you need at hand for the server enclosure 28 Upgrade and Maintenance Manual CX400 S2

29 Before you start Document Additional documentation Third party documentation Description RAID documentation, available online at under Industry standard servers - Expansion Cards - Storage Adapters Rack documentation Operating system documentation, online help Peripherals documentation Table 4: Documentation you need at hand for the server enclosure CX400 S2 Upgrade and Maintenance Manual 29

30 Before you start Documents for the server nodes Document "PRIMERGY CX250 S2 Server Node Operating Manual" "PRIMERGY CX250 S2 Server Node Upgrade and Maintenance Manual" "D3196 BIOS Setup Utility for PRIMERGY CX250 S2 Reference Manual" "PRIMERGY CX270 S2 Server Node Operating Manual" "PRIMERGY CX270 S2 Server Node Upgrade and Maintenance Manual" "D3196 BIOS Setup Utility for PRIMERGY CX270 S2 Reference Manual" Description Available online Available online Information on configurable BIOS options and parameters, available online Available online Available online Table 5: Documentation you need at hand for the server nodes Information on configurable BIOS options and parameters, available online 30 Upgrade and Maintenance Manual CX400 S2

31 3 Important information V CAUTION! Before installing and starting up a device, please observe the safety instructions listed in the following section. This will help you to avoid making serious errors that could impair your health, damage the device and endanger the data base. 3.1 Safety instructions I The following safety instructions are also provided in the manual "Safety Notes and Regulations" or " 安 全 上 のご 注 意 ". This device meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the server in the intended environment, please contact your sales outlet or our customer service team. The actions described in this manual shall be performed by technical specialists. A technical specialist is a person who is trained to install the server including hardware and software. Repairs to the device that do not relate to CSS failures shall be performed by service personnel. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability. Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment. Before installing/removing internal options to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cords from the power outlet. Failure to do so can cause electric shock or damage. Before starting up During installation and before operating the device, observe the instructions on environmental conditions for your device. If the device is brought in from a cold environment, condensation may form both inside and on the outside of the device. CX400 S2 Upgrade and Maintenance Manual 31

32 Important information Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed. Transport the device only in the original packaging or in packaging that protects it from knocks and jolts. For the Japanese market, transporting the device in its original packaging does not apply. Installation and operation This unit should not be operated in ambient temperatures above 35 C. If the unit is integrated into an installation that draws power from an industrial power supply network with an IEC309 connector, the power supply's fuse protection must comply with the requirements for non-industrial power supply networks for type A connectors. The unit automatically adjusts itself to a mains voltage in a range of 100 VAC to 240 VAC. (For the Japanese market there are two PSUs available: PSU for 100V is set to a mains voltage in the range of 100V - 240V). Ensure that the local mains voltage lies within these limits. This device must only be connected to properly grounded power outlets or connected to the grounded rack internal power distribution system with tested and approved power cords. Ensure that the device is connected to a properly grounded power outlet close to the device. Ensure that the power sockets on the device and the properly grounded power outlets are easily accessible. The On/Off button or the main power switch (if present) does not isolate the device from the mains power supply. In case of repair or servicing disconnect the device completely from the mains power supply, unplug all power plugs from the properly grounded power outlets. Always connect the server and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the server is still running but a peripheral device (e.g. memory subsystem) fails during a power outage. Data cables must be adequately shielded. 32 Upgrade and Maintenance Manual CX400 S2

33 Important information Ethernet cabling has to comply with EN and EN /2 standards or ISO/IEC standard respectively. The minimum requirement is a Category 5 shielded cable for 10/100 Ethernet, or a Category 5e cable for Gigabit Ethernet. Route the cables in such a way that they do not create a potential hazard (make sure no-one can trip over them) and that they cannot be damaged. When connecting the server, refer to the relevant instructions in this manual. Never connect or disconnect data transmission lines during a storm (risk of lightning hazard). Make sure that no objects (e.g. jewelry, paperclips etc.) or liquids can get inside the server (risk of electric shock, short circuit). In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign bodies), contact the system administrator or your customer service team. Only disconnect the system from the mains power supply if there is no risk of harming yourself. Proper operation of the system (in accordance with IEC resp. EN ) is only ensured if the casing is completely assembled and the rear covers for the installation slots have been fitted (electric shock, cooling, fire protection, interference suppression). Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and those relating to telecommunication terminals. If you install other expansions, they may damage the system or violate the safety regulations. Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet. The components marked with a warning notice (e.g. lightning symbol) may only be opened, removed or exchanged by authorized, qualified personnel. Exception: CSS components can be replaced. The warranty is void if the server is damaged during installation or replacement of system expansions. Only set screen resolutions and refresh rates that are specified in the operating manual for the monitor. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service center. Before installing/removing internal options to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cords from the outlet. Failure to do so can cause electric shock. CX400 S2 Upgrade and Maintenance Manual 33

34 Important information Do not damage or modify internal cables or devices. Doing so may cause a device failure, fire, or electric shock and will void the warranty and exempt the manufacturer from all liability. Devices inside the server remain hot after shutdown. Wait for a while after shutdown before installing or removing internal options. The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. To ensure reliable protection, if you are wearing an earthing band on your wrist when working with this type of module, connect it to an unpainted, non-conducting metal part of the system. Do not touch the circuitry on boards or soldered parts. Hold the metallic areas or the edges of the circuit boards. Install the screw removed during installation/detaching internal options in former device/position. To use a screw of the different kind can cause a breakdown of equipment. The installation indicated on this document is sometimes changed to the kind of possible options without notice. Modules with Electrostatic-Sensitive Devices Modules with electrostatic-sensitive devices are identified by the following sticker: Figure 1: ESD label When you handle components fitted with ESDs, you must always observe the following points: Switch off the system and remove the power plugs from the power outlets before installing or removing components with ESDs. 34 Upgrade and Maintenance Manual CX400 S2

35 Important information The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. To ensure reliable protection, you must wear an earthing band on your wrist when working with this type of module and connect it to an unpainted, non-conducting metal part of the system. Any devices or tools that are used must be free of electrostatic charge. Wear a suitable grounding cable that connects you to the external chassis of the system unit. Always hold components with ESDs at the edges or at the points marked green (touch points). Do not touch any connectors or conduction paths on an ESD. Place all the components on a pad which is free of electrostatic charge. I For a detailed description of how to handle ESD components, see the relevant European or international standards (EN , ANSI/ESD S20.20). CX400 S2 Upgrade and Maintenance Manual 35

36 Important information Transporting the server Only transport the server in its original packaging or in packaging that protects it from impacts and jolts. For the Japanese market, transporting the device in its original packaging does not apply. Do not unpack the server until it is at its installation location. If you need to lift or transport the server, ask other people to help you. Because the PRIMERGY CX400 S2 is large and heavy, at least two people are needed. Never lift or carry the device by the handles on the front panel. Notes on installing the server in the rack For safety reasons, at least two people are required to install the server in the rack because of its weight and size. (For the Japanese market, please refer to " 安 全 上 のご 注 意 ".) Never lift the server into the rack using the handles on the front panel. When connecting and disconnecting cables, observe the relevant instructions in the "Important Information" chapter of the technical manual for the corresponding rack. The technical manual is supplied with the corresponding rack. When installing the rack, make sure that the anti-tilt protection is correctly fitted. For safety reasons, no more than one unit may be removed from the rack at any one time during installation and maintenance work. If several units are simultaneously removed from the rack, there is a risk that the rack could tip over. The rack must be connected to the power supply by an authorized specialist (electrician). If the server is integrated into an installation that draws power from an industrial power supply network with an IEC309 type connector, the power supply's fuse protection must comply with the requirements for nonindustrial power supply networks for the type A connector. 36 Upgrade and Maintenance Manual CX400 S2

37 Important information 3.2 CE conformity The system complies with the requirements of the EC directives 2004/108/EC regarding "Electromagnetic Compatibility" and 2006/95/EC "Low Voltage Directive". This is indicated by the CE marking (CE = Communauté Européenne). CX400 S2 Upgrade and Maintenance Manual 37

38 Important information 3.3 FCC Class A Compliance Statement If there is an FCC statement on the device, it applies to the products covered in this manual, unless otherwise specified herein. The statement for other products will appear in the accompanying documentation. NOTE: This equipment has been tested and found to comply with the limits for a "Class A" digital device, pursuant to Part 15 of the FCC rules and meets all requirements of the Canadian Interference-Causing Equipment Standard ICES-003 for digital apparatus. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in strict accordance with the instructions, may cause harmful interference to radio communications. However, there is no warranty that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between equipment and the receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. Fujitsu is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Fujitsu. The correction of interferences caused by such unauthorized modification, substitution or attachment will be the responsibility of the user. The use of shielded I/O cables is required when connecting this equipment to any and all optional peripheral or host devices. Failure to do so may violate FCC and ICES rules. WARNING: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. 38 Upgrade and Maintenance Manual CX400 S2

39 Important information 3.4 Environmental protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu standard for "environmentally friendly product design and development". This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account. This saves resources and thus reduces the harm done to the environment. Further information can be found at: (for the EMEA market) (for the Japanese market) Energy-saving information Devices that do not need to be constantly switched on should be switched off until they are needed as well as during long breaks and after completion of work. Packaging information This packaging information doesn t apply to the Japanese market. Do not throw away the packaging. You may need it later for transporting the system. If possible, the equipment should only be transported in its original packaging. Information on handling consumables Please dispose of printer consumables and batteries in accordance with the applicable national regulations. In accordance with EU directives, batteries must not be disposed of with unsorted domestic waste. They can be returned free of charge to the manufacturer, dealer or an authorized agent for recycling or disposal. All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). They are also marked with the chemical symbol for the heavy metal that causes them to be categorized as containing pollutants: Cd Cadmium Hg Mercury Pb Lead CX400 S2 Upgrade and Maintenance Manual 39

40 Important information Labels on plastic casing parts Please avoid sticking your own labels on plastic parts wherever possible, since this makes it difficult to recycle them. Returns, recycling and disposal Please handle returns, recycling and disposal in accordance with local regulations. The device must not be disposed of with domestic waste. This device is labeled in compliance with European directive 2002/96/EC on waste electrical and electronic equipment (WEEE). This directive sets the framework for returning and recycling used equipment and is valid across the EU. When returning your used device, please use the return and collection systems available to you. Further information can be found at Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu branch or from our recycling center in Paderborn: Fujitsu Technology Solutions Recycling Center D Paderborn Tel Fax Upgrade and Maintenance Manual CX400 S2

41 4 Basic hardware procedures 4.1 Shutting down the server node Safety notes V CAUTION! For further safety information, please refer to chapter "Important information" on page 31. I This step is only required when upgrading or replacing non-hot plug components. Inform the system administrator that the server node will be shut down and put offline. Terminate all applications. Press the On/Off button either on the rear or on the corresponding front panel to shut down the server node. I If the system is running an ACPI-compliant operating system, pressing the On / Off button will perform a graceful shutdown. CX400 S2 Upgrade and Maintenance Manual 41

42 Basic hardware procedures 4.2 Disconnecting the power cord I Before disconnecting the power cord all server nodes must be shut down. Figure 2: Removing the power cord from the PSU cable tie Pull out the locking lever on the PSU cable tie (1) and loosen the loop (2). Disconnect the power cord from the PSU and remove it from the cable tie. 42 Upgrade and Maintenance Manual CX400 S2

43 Basic hardware procedures 4.3 Removing the server enclosure out of the rack V CAUTION! For ALL service tasks, remove the CX400 S2 server enclosure out of the rack and put it on a separate desk, except when you remove / install HDD, PSU and Server Node! It is not allowed to draw the CX400 S2 server enclosure partially out of the rack Preliminary steps "Shutting down the server node" on page 41 "Disconnecting the power cord" on page 42 If applicable, disconnect all external cables. If you remove the CX400 S2 server enclosure out of the rack, remove all HDD, PSU and Server Node from the server enclosure. CX400 S2 Upgrade and Maintenance Manual 43

44 Basic hardware procedures Removing the rear fixing brackets Figure 3: Loosen the rear fixing brackets with screws Loosen the two rear fixing brackets by removing the two screws on each side. Figure 4: Rear fixing brackets for the rail kit cage nuts Remove the two rear fixing brackets on each side. 44 Upgrade and Maintenance Manual CX400 S2

45 Basic hardware procedures Removing the server enclosure out of the rack V CAUTION! At least two people are needed to lift the server out of the rack cabinet. For the Japanese market, according to the following procedures. If you remove the CX400 S2 server enclosure out of the rack, remove all HDD, PSU and Server Node from the server enclosure. In addition, at least two people are needed when server enclosure is installed in the height of 25U or more. (For the Japanese market, please refer to " 安 全 上 のご 注 意 ".) Applies only to EMEA market as follows For configurations below 32 kg: At least two people are needed to lift the server out of the rack cabinet. For configurations below 55 kg: At least three people are needed to lift the server out of the rack cabinet. For configurations above 55 kg: At least four people are needed to lift the server out of the rack cabinet. CX400 S2 Upgrade and Maintenance Manual 45

46 Basic hardware procedures The description of following Riftar is applied only to the EMEA market. Additionally, a lifter is required in the following cases: The server weighs more than 50 kg. The server weighs more than 21 kg and is installed above the height of 25 U. When using a lifter, this removal procedure needs to be carried out by maintenance personnel. Figure 5: Remove the server enclosure out of the rack (A). Remove the screw on the front bracket. 46 Upgrade and Maintenance Manual CX400 S2

47 Basic hardware procedures Figure 6: Remove the server enclosure out of the rack (B). Pull out the chassis from the rack. I Remove the server enclosure from the rack carefully. Must be done with at least two people. CX400 S2 Upgrade and Maintenance Manual 47

48 Basic hardware procedures 4.4 Removing the server node from the server enclosure I The CX400 S2 system must always run with closed node bays. It is only allowed to leave a bay open for a limited time in case of repairing a server node (for example). In this case the node bay must be closed within one hour. In the meantime all remaining server nodes run in throttling mode (with reduced performance) Removing the server node CX250 S2 V CAUTION! Shut down the server node and disconnect all external cables. Follow the safety instructions in the chapter "Important information" on page 31. Figure 7: Removing the server node CX250 S2 Undo the locking mechanism (1) of the release lever and pull the server node out of the slot (2). 48 Upgrade and Maintenance Manual CX400 S2

49 Basic hardware procedures Removing the server node CX270 S2 I The CX400 S2 system must always run with closed node bays. It is only allowed to leave a bay open for a limited time in case of repairing a server node (for example). In this case the node bay must be closed within one hour. In the meantime all remaining server nodes run in throttling mode (with reduced performance). V CAUTION! Shut down the server node and disconnect all external cables. Follow the safety instructions in the chapter "Important information" on page 31. Figure 8: Removing the server node CX270 S2 Undo the locking mechanism (1) of the release lever and pull the server node out of the slot (2). CX400 S2 Upgrade and Maintenance Manual 49

50 Basic hardware procedures 4.5 Removing the server node dummy module I The CX400 S2 system must always run with closed node bays. It is only allowed to leave a bay open for a limited time in case of repairing a server node (for example). In this case the node bay must be closed within one hour. In the meantime all remaining server nodes run in throttling mode (with reduced performance). V CAUTION! Follow the safety instructions in the chapter "Important information" on page 31. Figure 9: Removing the server node dummy module Undo the locking mechanism (1) of the release lever and pull the server node dummy module out of the slot (2). 50 Upgrade and Maintenance Manual CX400 S2

51 Basic hardware procedures 4.6 Opening the server enclosure V CAUTION! Before removing or installing covers, turn off the server nodes and all peripheral devices. Also unplug all power cables from the outlet. Failure to do so can cause electric shock. For further safety information, please refer to chapter "Important information" on page inch chassis Removing the top cover 1 Removing the top cover 1 allows you to replace the power distribution board, the midplane and the fans. Figure 10: Removing the top cover 1 from the 2.5-inch chassis (A) Remove twelve screws from the top cover. CX400 S2 Upgrade and Maintenance Manual 51

52 Basic hardware procedures Figure 11: Removing the top cover 1 from the 2.5-inch chassis (B) Lift the top cover (1), slide it in the direction of the arrow (2) and remove it Removing the top cover 2 Removing the top cover 2 allows you also to replace the linking boards, HDD backplane and the front panel cable. Figure 12: Removing the top cover 2 from the 2.5-inch chassis (A) Remove six screws and lift it up the top cover (1). 52 Upgrade and Maintenance Manual CX400 S2

53 Basic hardware procedures inch chassis Removing the top cover Figure 13: Removing the top cover from the 3.5-inch chassis (A) Remove twelve screws from the top cover. Figure 14: Removing the top cover from the 3.5-inch chassis (B) Lift the top cover (1), slide it in the direction of the arrow (2) and remove it. CX400 S2 Upgrade and Maintenance Manual 53

54 Basic hardware procedures 4.7 Removing the power distribution module Remove the power supply modules as described in section "Removing the power supply module" on page 84. Figure 15: Disconnecting the fan cables Disconnect the fan cable C3 from the top PDB (1), see also "Connectors on the PDB" on page 135. Remove six screws (2). Remove the mounting bracket. I For information about the cabling refer to chapter "Cabling" on page Upgrade and Maintenance Manual CX400 S2

55 Basic hardware procedures Figure 16: Removing the power distribution module (A) Disconnect all power cables from the boards: Cable C1 and C2 from the HDD backplanes Cable C4, C6 and C7 from the midplane Slide the power cables trough the recess to get access to the screws. Disconnect the fan cable C3 from the bottom PDB (1), see also "Connectors on the PDB" on page 135. Remove two screws (2). I For information about the cabling refer to chapter "Cabling" on page 191. CX400 S2 Upgrade and Maintenance Manual 55

56 Basic hardware procedures Figure 17: Removing the power distribution module (B) Push the power distribution module in the direction of the arrow. Figure 18: Removing the power distribution module (C) Lift the power distribution module out of the chassis. Remove all cables from the power distribution module. I Take note of the cable positions. 56 Upgrade and Maintenance Manual CX400 S2

57 Basic hardware procedures 4.8 Installing the power distribution module Figure 19: Mounting positions in the chassis Figure 20: Mounting positions on the power distribution module CX400 S2 Upgrade and Maintenance Manual 57

58 Basic hardware procedures Figure 21: Power distribution module without cables Connect the power cables to the boards: Cable C1 to JP6 top PDB Cable C2 to JP6 bottom PDB Cable C4 to J2 top PDB Cable C4 to J2 bottom PDB Cable C6 to MB1_PWR_CONN top PDB Cable C6 to MB2_PWR_CONN top PDB Cable C7 to MB3_PWR_CONN bottom PDB Cable C7 to MB4_PWR_CONN bottom PDB I For information about the cabling refer to chapter "Cabling" on page Upgrade and Maintenance Manual CX400 S2

59 Basic hardware procedures Figure 22: Installing the power distribution module (A) Slide the power distribution module in the chassis. The recess must fit with the bolts see figure 20 and figure 19 (1). Figure 23: Installing the power distribution module (B) Push the power distribution module in the direction of the arrow. CX400 S2 Upgrade and Maintenance Manual 59

60 Basic hardware procedures Figure 24: Installing the power distribution module (C) Secure the power distribution board with two screws. Figure 25: Connecting the fan cables Slide the power cables trough the recess. Connect the fan cables C3 to the top and bottom PDBs (1). For information about the fan cabling refer to chapter "Connectors on the PDB" on page 135 and chapter "Cabling" on page 191. Connect the power cables to the midplane and the HDD/SSD backplane. For information about the cabling refer to chapter "Cabling" on page 191. Secure the mounting bracket with six screws (2). 60 Upgrade and Maintenance Manual CX400 S2

61 Basic hardware procedures Install the power supply module as described in section "Installing the power supply module" on page Closing the server enclosure V CAUTION! Before attaching the covers, make sure no unnecessary parts or tools are left inside the server. For further safety information, please refer to chapter "Important information" on page inch chassis Installing the top cover 2 Figure 26: Installing the top cover 2 on the 2.5-inch chassis (A) Place the top cover 2 on the chassis. Secure the top cover 2 with six screws. CX400 S2 Upgrade and Maintenance Manual 61

62 Basic hardware procedures Installing the top cover 1 Figure 27: Installing the top cover 1 on the 2.5-inch chassis (A) Insert the top cover 1 in a slight angle (1) and slide it in the direction of the arrow (2). Figure 28: Installing the top cover 1 on the 2.5-inch chassis (B) Push the top cover 1 down and secure it with twelve screws. 62 Upgrade and Maintenance Manual CX400 S2

63 Basic hardware procedures inch chassis Installing the top cover Figure 29: Installing the top cover on the 3.5-inch chassis (A) Insert the top cover in a slight angle (1) and slide it in the direction of the arrow (2). Figure 30: Installing the top cover from the 3.5-inch chassis (B) Push the top cover down and secure it with twelve screws. CX400 S2 Upgrade and Maintenance Manual 63

64 Basic hardware procedures 4.10 Installing the server node dummy module V CAUTION! Follow the safety instructions in the chapter "Important information" on page 31. Figure 31: Installing the server node dummy module Carefully push the server node at the handle into the server enclosure until the locking mechanism snaps into place. 64 Upgrade and Maintenance Manual CX400 S2

65 Basic hardware procedures 4.11 Installing the server node in the server enclosure Basic information Population rules for server nodes CX250 S2 Figure 32: Population rules for server nodes CX250 S2 1 Server node CX250 S2 bay 1 2 Server node CX250 S2 bay 2 3 Server node CX250 S2 bay 3 4 Server node CX250 S2 bay 4 Population rules for server nodes CX270 S2 Figure 33: Population rules for server nodes CX270 S2 1 Server node CX270 S2 bay 1 2 Server node CX270 S2 bay 2 I Not used bays must be equipped with server node dummy modules. CX400 S2 Upgrade and Maintenance Manual 65

66 Basic hardware procedures Installing server node CX250 S2 V CAUTION! Follow the safety instructions in the chapter "Important information" on page 31. Figure 34: Installing the server node Push the server node at the handle into the server enclosure until the locking mechanism snaps into place. If applicable, connect all external cables to the server node Installing server node CX270 S2 V CAUTION! Follow the safety instructions in the chapter "Important information" on page Upgrade and Maintenance Manual CX400 S2

67 Basic hardware procedures Figure 35: Installing the server node Push the server node at the handle into the server enclosure until the locking mechanism snaps into place. If applicable, connect all external cables to the server node Mounting the server enclosure in the rack Seating the server on the rack rails V CAUTION! At least two people are needed to position the server on the rack rails. (For the Japanese market, please refer to " 安 全 上 のご 注 意 ".) CX400 S2 Upgrade and Maintenance Manual 67

68 Basic hardware procedures For configurations below 32 kg: At least two people are needed to lift the server into the rack cabinet. For configurations below 55 kg: At least three people are needed to lift the server into the rack cabinet. For configurations above 55 kg: At least four people are needed to lift the server into the rack cabinet. Additionally, a lifter is required in the following cases: The server weighs more than 50 kg. The server weighs more than 21 kg and is to be installed above the height of 25 U. When using a lifter, this installation procedure needs to be carried out by maintenance personnel. 68 Upgrade and Maintenance Manual CX400 S2

69 Basic hardware procedures Figure 36: Mounting the server enclosure into the rack (A). Install the server enclosure into the rack. I At least two people are needed to position the server on the rack rails. CX400 S2 Upgrade and Maintenance Manual 69

70 Basic hardware procedures Figure 37: Mounting the server into the rack (B). Secure the screw on the front bracket (screw torque: 25 in-lb). 70 Upgrade and Maintenance Manual CX400 S2

71 Basic hardware procedures Installing the rail kit cage nut Figure 38: Installing two rail kit cage nuts in the rack mounting holes on each side Install two rail kit cage nuts in the rack mounting holes on each side. Figure 39: Rear fixing brackets for the rail kit cage nuts Install the two rear fixing brackets on each side. CX400 S2 Upgrade and Maintenance Manual 71

72 Basic hardware procedures Figure 40: Fastening the rear fixing brackets with screws Fasten the two rear fixing brackets with two screws on each side. 72 Upgrade and Maintenance Manual CX400 S2

73 Basic hardware procedures 4.13 Connecting the power cord Connect the power cord to the server enclosure PSU. Connect the mains connector to an outlet on the rack's socket strip (see also Technical Manual for the rack). I A phase redundancy in the power supply of the server enclosure can be set up if two hot-plug PSUs are installed. In this case, each of the PSUs is either connected to two different phases or to two separate circuits of the internal power supply network. Ensure that the indicator on the PSU lights up green. I For more information see section "Power supply module" on page 208. CX400 S2 Upgrade and Maintenance Manual 73

74 Basic hardware procedures Figure 41: Securing the power cord with the cable tie Loop the cable tie around the power cord and the handle of the power supply module (1). Pull tight the cable tie (2) to secure the power cord. 74 Upgrade and Maintenance Manual CX400 S2

75 Basic hardware procedures 4.14 Switching on the server node(s) V CAUTION! Follow the safety instructions in chapter "Important information" on page 31. If applicable, connect all external cables to the server node. Figure 42: Controls and indicators of the server node 1 ID indicator 2 On/Off button / Power-on indicator Press the On/Off button either on the rear or on the corresponding front panel to start up the server node. The power-on indicator is lit green and the ID indicator is off. I For more information, refer to section "Front panel" on page 205. CX400 S2 Upgrade and Maintenance Manual 75

76 Basic hardware procedures 76 Upgrade and Maintenance Manual CX400 S2

77 5 Basic software procedures 5.1 Starting the maintenance task Switching on the ID indicator When working in a datacenter environment, switch on the ID indicator on the front panels of the server for easy identification. The ID indicator can also be activated via the BMC Web interface and its status reported to the BMC. Using the ID button on the front panel Press the ID button on the front panel to switch on the system identification LEDs. I For further information, refer to section "Front panel" on page Completing the maintenance task Switching off the ID indicator Press the ID button on the front panel. The ID indicator can also be deactivated via the BMC Web interface and its status reported to the BMC. Using the ID button on the front panel Press the ID button on the front panel to switch off the ID indicators. CX400 S2 Upgrade and Maintenance Manual 77

78 Basic software procedures Performing a RAID array rebuild After replacing a hard disk drive that has been combined into a RAID array, RAID rebuild will be performed completely unattended as a background process. Figure 43: Progress bar (RAID array rebuild) V CAUTION! The system is now operational, however, data redundancy will not be available until the RAID array rebuild is complete. Depending on the hard disk drive capacity the overall process can take up to several hours, in some cases even days. I You may notice a slight performance impact during rebuild Using the Chassis ID Prom Tool System information like server name and model, housing type, serial number and manufacturing data are stored in the PDB or HDD backplane. In order to integrate your system into the ServerView management environment and to enable server installation using the ServerView Installation Manager, system data needs to be complete and correct. After replacing the PDB or HDD backplane, system information has to be entered using the ChassisId_Prom Tool. The tool and further instructions are available to maintenance personnel from the Fujitsu Technology Solutions Extranet: I For the Japanese market, follow the instructions provided separately. 78 Upgrade and Maintenance Manual CX400 S2

79 6 Power supply Safety notes V CAUTION! Do not disassemble the power supply unit. Doing so may cause electric shock. Areas around the power supply unit may remain extremely hot after shutdown. After shutting down the server, wait for hot components to cool down before removing the power supply unit. When installing the power supply unit, be sure to confirm that the connector of the power supply unit is not damaged or bent. Do not insert your hands in the power supply unit slot when removing the power supply unit. Doing so may cause electric shock. If the power supply unit is hard to remove, do not pull out it by force. The power supply unit is heavy, so handle it carefully. If you drop it by mistake, injuries may result. Follow the safety instructions in the chapter "Important information" on page Basic information The server enclosure uses a hot-plug PSU, which automatically sets itself to a mains voltage in the range of V. (For the Japanese market there are two PSUs available: PSU for 100V is set to a mains voltage in the range of 100V - 240V). As an option, the power supply can be expanded with an extra PSU to create a redundant power supply. If a PSU fails, the redundant configuration assures continued operation. The defective PSU can be replaced during operation. Complete PSU redundancy will work only in one-node configuration. In a multi-node configuration, full redundancy cannot be guaranteed. In case of PSU failure a warning is generated and all CPUs will be forced to work with the lowest frequency. CX400 S2 Upgrade and Maintenance Manual 79

80 Power supply Some configurations need two PSUs for normal operation. In this configurations a redundancy is not possible even if two PSUs are built-in. In this configurations, if one PSU failed, system can continue to work. but it goes to a throttling mode and it affects performance until replacement of the PSU General equipping rules Figure 44: Population rules for the power supply modules 1 Power supply module bay 1 (top) 2 Power supply module bay 2 (bottom) Both power supply modules must be of the same type. 6.2 Installing the power supply module Customer Replaceable Units (CRU) 80 Upgrade and Maintenance Manual CX400 S2

81 Power supply Average task duration: 5 minutes Required tools Preliminary and concluding steps: tool-less Main steps: tool-less Removing the dummy cover Figure 45: Removing the dummy cover Push the handle of the dummy cover in the direction of the arrow (1). Swivel out the dummy cover (2) and remove it. V CAUTION! Keep the dummy cover for future use. If the power supply module is removed and not replaced with a new one, the dummy cover must be reinstalled due to cooling, to comply with applicable EMC regulations (regulations on electromagnetic compatibility), and to protect against fire. CX400 S2 Upgrade and Maintenance Manual 81

82 Power supply Installing the power supply module Figure 46: Unlocking the power supply module Push the handle of the power supply module in the direction of the arrow. 82 Upgrade and Maintenance Manual CX400 S2

83 Power supply Figure 47: Installing the power supply module Carefully push the power supply module into the empty bay (1) until it stops. Push the handle of the power supply module as far as it will go in the direction of the arrow (2). I Make sure that the power supply module engages correctly in the bay and is locked in position. This is the only way to prevent the power supply unit from sliding out of its bay and being damaged during transportation Concluding steps Perform the following procedures: "Connecting the power cord" on page 73. CX400 S2 Upgrade and Maintenance Manual 83

84 Power supply 6.3 Removing the power supply module Customer Replaceable Units (CRU) Average task duration: 5 minutes Required tools Preliminary and concluding steps: tool-less Main steps: tool-less Preliminary steps Perform the following procedures: "Disconnecting the power cord" on page 42. Figure 48: Removing the power supply module Pull the handle of the power supply module halfway upward in the direction of the arrow (1). 84 Upgrade and Maintenance Manual CX400 S2

85 Power supply Push the lock in direction of the arrow (2). Grip the handle and pull out the power supply module in the direction of the arrow (3). V CAUTION! Never leave the bay for the power supply module empty for more than two minutes during operation. Otherwise, excessive temperatures could damage system components Installing the dummy cover Figure 49: Installing the power supply dummy cover Attach the dummy cover on the left side (1). I Ensure the correct direction (marked with an arrow on the dummy cover). Close the dummy cover (2) until it fits into place. CX400 S2 Upgrade and Maintenance Manual 85

86 Power supply 6.4 Replacing the power supply module Customer Replaceable Units (CRU) Average task duration: 5 minutes V CAUTION! When replacing a power supply module in a non-redundant configuration, the server must be switched off first. Replace the power supply module after specifying the one that breaks down at work by revitalization. Both power supply modules must be of the same type Required tools Preliminary and concluding steps: tool-less Main steps: tool-less Preliminary steps Perform the following procedures: Only when replacing a power supply module in a non-redundant configuration: "Shutting down the server node" on page 41 Check which power supply module is defective. A power supply module is defective when the indicator on the PSU module lights up yellow. I For more information see section "Power supply module" on page Upgrade and Maintenance Manual CX400 S2

87 Power supply Removing the defective power supply module Remove the power supply module as described in section "Removing the power supply module" on page Installing the new power supply module Install the power supply module as described in section "Installing the power supply module" on page Concluding steps Perform the following procedures: "Connecting the power cord" on page 73. Only when replacing a power supply module in a non-redundant configuration: "Switching on the server node(s)" on page 75. CX400 S2 Upgrade and Maintenance Manual 87

88 Power supply 6.5 Replacing the power distribution board Replacing the defective top PDB Field Replaceable Units (FRU) Average hardware task duration: 25 minutes Average software task duration: 5 minutes Note on system information The top PDB contains the Chassis ID EPROM that contains system information like server name and model, housing type, serial number and manufacturing data Required tools Preliminary and concluding steps: Phillips PH2 / (+) No. 2 screw driver Main steps: Phillips PH2 / (+) No. 2 screw driver Preliminary steps Perform the following procedures: "Shutting down the server node" on page 41 "Removing the server enclosure out of the rack" on page 43 V CAUTION! For ALL service tasks, remove the CX400 S2 server enclosure out of the rack and put it on a separate desk! 88 Upgrade and Maintenance Manual CX400 S2

89 Power supply It is not allowed to draw the CX400 S2server enclosure partially out of the rack. "Removing the server node from the server enclosure" on page 48 "Removing the power supply module" on page 84 "Opening the server enclosure" on page 51 "Removing the power distribution module" on page Removing the top PDB Figure 50: Removing top PDB (A) Remove four screws to loosen the board from the cage. Figure 51: Removing top PDB (B) CX400 S2 Upgrade and Maintenance Manual 89

90 Power supply Remove four screws to loosen the board from the standoffs. Figure 52: Removing top PDB (C) Carefully push down the board to disengage the pin header (1). Remove the board in the direction of the arrow (2). 90 Upgrade and Maintenance Manual CX400 S2

91 Power supply Installing the top PDB Figure 53: Installing the top PDB (A) Carefully insert the board in the direction of the arrow (1). The connector on the top PDB must fit with the pin header (2). Carefully press the board in the direction of the arrow (3). Ensure that the pin header is properly connected. Figure 54: Installing the top PDB (B) CX400 S2 Upgrade and Maintenance Manual 91

92 Power supply Secure the board with four screws on the standoffs. Figure 55: Installing the top PDB (C) Secure the board with four screws in the cage Concluding steps Perform the following procedures: "Installing the power distribution module" on page 57 "Closing the server enclosure" on page 61 "Installing the power supply module" on page 80 "Installing the server node in the server enclosure" on page 65 "Mounting the server enclosure in the rack" on page 67 "Switching on the server node(s)" on page 75 "Using the Chassis ID Prom Tool" on page Upgrade and Maintenance Manual CX400 S2

93 Power supply Replacing the defective bottom PDB Field Replaceable Units (FRU) Average hardware task duration: 25 minutes Average software task duration: 5 minutes Note on system information The bottom PDB contains the Chassis ID EPROM that contains system information like server name and model, housing type, serial number and manufacturing data Required tools Preliminary and concluding steps: Phillips PH2 / (+) No. 2 screw driver Main steps: Phillips PH2 / (+) No. 2 screw driver Preliminary steps Perform the following procedures: "Shutting down the server node" on page 41 "Removing the server enclosure out of the rack" on page 43 V CAUTION! For ALL service tasks, remove the CX400 S2 server enclosure out of the rack and put it on a separate desk! It is not allowed to draw the CX400 S2server enclosure partially out of the rack. "Removing the server node from the server enclosure" on page 48 CX400 S2 Upgrade and Maintenance Manual 93

94 Power supply "Removing the power supply module" on page 84 "Opening the server enclosure" on page 51 "Removing the power distribution module" on page Removing the bottom PDB Figure 56: Removing bottom PDB (A) Remove six screws to loosen the board from the cage. Figure 57: Removing bottom PDB (B) Remove four screws to loosen the board from the standoffs. 94 Upgrade and Maintenance Manual CX400 S2

95 Power supply Figure 58: Removing bottom PDB (C) Carefully lift up the board to disengage the pin header (1). Remove the board in the direction of the arrow (2). CX400 S2 Upgrade and Maintenance Manual 95

96 Power supply Installing the bottom PDB Figure 59: Installing bottom PDB (A) Carefully insert the board in the direction of the arrow (1). The connector on the bottom PDB must fit with the pin header (2). Carefully press the board in the direction of the arrow (3). Ensure that the pin header is properly connected. 96 Upgrade and Maintenance Manual CX400 S2

97 Power supply Figure 60: Installing bottom PDB (B) Secure the board with four screws on the standoffs. Figure 61: Installing bottom PDB (C) Secure the board with six screws in the cage. CX400 S2 Upgrade and Maintenance Manual 97

98 Power supply Concluding steps Perform the following procedures: "Installing the power distribution module" on page 57 "Closing the server enclosure" on page 61 "Installing the power supply module" on page 80 "Installing the server node in the server enclosure" on page 65 "Mounting the server enclosure in the rack" on page 67 "Switching on the server node(s)" on page 75 "Using the Chassis ID Prom Tool" on page Upgrade and Maintenance Manual CX400 S2

99 7 Hard disk drives / solid state drives Safety notes V CAUTION! The hard disk drive must not be removed from the installation frame by anyone except a service technician. HDD / SSD modules must all be marked clearly so that they can be reinstalled into their original mounting locations after an upgrade. Otherwise, data may be lost. Do not touch the circuitry on boards or soldered parts. Hold the metallic areas or the edges of the circuit boards. Before removing a hard disk drive, wait for about 30 seconds until the disk has stopped spinning completely. When a hard disk drive is starting up, a resonant noise may be audible for a short while. This does not indicate a failure. Depending on the OS, you can configure the write cache settings for the hard disk drives. If a power failure should occur while the write cache is enabled, cached data may be lost. When disposing of, transferring, or returning a hard disk or solid state drive, wipe out the data on the drive for your own security. Rough handling of hard disk drives may damage the stored data. To cope with any unexpected problems, always back up important data. When backing up data to another hard disk drive, you should make backups on a file or partition basis. Be careful not to hit the hard disk drive or bring it into contact with metallic objects. Handle the device on a shock and vibration free surface. Do not use the device in extremely hot or cold locations, or locations with extreme temperature changes. Never attempt to disassemble a hard disk or solid state drive. For further safety information, please refer to chapter "Important information" on page 31. CX400 S2 Upgrade and Maintenance Manual 99

100 Hard disk drives / solid state drives 7.1 Basic information Hard disk drives The server enclosure can be equipped with a maximum of 24 x 2.5-inch HDD/SSDs or 12 x 3.5-inch HDD modules. Each HDD module can accommodate an SAS/SATA hard disk drive or SSD drive with a maximum height of 1 inch. The module is connected to the SAS/SATA backplane wirelessly. This allows HDD/SSD modules to be plugged in or pulled out easily. Six SAS/SATA hard disk drives can be controlled by the onboard SAS/SATA controller. To control further SAS/SATA hard disk drives, an additional RAID controller must be installed. Hybrid configurations of SAS HDDs, SATA HDDs and SSDs within the same logical drive (RAID array) are not supported. If the server enclosure has the corresponding RAID configuration, HDD modules can also be replaced during operation General equipping rules Solid state drives (SSDs) are always equipped before installing hard disk drives. Hard disk drives / solid state drives with different capacities are installed from highest to lowest capacity. Hard disk drives with different rotation speeds are installed from highest to lowest speed. When installing hard disk drives with different bus technologies (SAS or SATA), first install SAS drives and then SATA drives. Please refer to sections "HDD/SSD install order in the 2.5-inch chassis" on page 101 or "HDD install order in the 3.5-inch chassis" on page 110 for a complete overview of the mounting sequence. Install dummy modules into unused HDD/SSD bays. 100 Upgrade and Maintenance Manual CX400 S2

101 Hard disk drives / solid state drives inch hard disk drives / solid state drives HDD/SSD install order in the 2.5-inch chassis Server node 1 HDD bay Server node 2 HDD bay Server node 3 HDD bay Server node 4 HDD bay Figure 62: HDD/SSD install order in the 2.5-inch chassis CX400 S2 Upgrade and Maintenance Manual 101

102 Hard disk drives / solid state drives Configuration with standard CPU Figure 63: Configuration with standard CPU Configuration with 130 W (6 core) or 130 W (4 core) CPU support Figure 64: Configuration with 135 W (8 core) or 130 W (4 core) CPU support 102 Upgrade and Maintenance Manual CX400 S2

103 Hard disk drives / solid state drives Installing 2.5-inch HDD/SSD modules Customer Replaceable Units (CRU) Average task duration: 5 minutes Required tools Preliminary and concluding steps: tool-less Main steps: tool-less Preliminary steps Perform the following procedures: Locate the correct drive bay as described in section "HDD/SSD install order in the 2.5-inch chassis" on page 101. CX400 S2 Upgrade and Maintenance Manual 103

104 Hard disk drives / solid state drives Removing a 2.5-inch HDD/SSD tray Figure 65: Removing a 2.5-inch HDD/SSD tray I Empty HDD/SSD trays have been installed into unused HDD/SSD bays. Before installing an additional HDD/SSD, the empty HDD/SSD tray needs to be removed from the desired drive bay. Undo the locking mechanism of the release lever (1). Swing the release lever in the direction of the arrow (2). Pull out the HDD/SSD tray (3). 104 Upgrade and Maintenance Manual CX400 S2

105 Hard disk drives / solid state drives Installing a 2.5-inch HDD/SSD module Figure 66: Installing the 2.5-inch HDD/SSD module Insert the HDD/SSD module into a drive bay and carefully push back as far as it will go (1). Close the release lever in the direction of the arrow (2) Concluding steps Perform the following procedures: "Performing a RAID array rebuild" on page 78 CX400 S2 Upgrade and Maintenance Manual 105

106 Hard disk drives / solid state drives Removing 2.5-inch HDD/SSD modules Customer Replaceable Units (CRU) Average task duration: 5 minutes Required tools Preliminary and concluding steps: tool-less Main steps: tool-less Preliminary steps Perform the following procedures: Ensure that the HDD/SSD module to be removed is not combined into a RAID array. If the drive is part of a RAID array, you first need to delete the array using ServerView RAID Manager. V CAUTION! All data on all HDDs/SSDs in the array will be lost! Be sure to back up your data before deleting a RAID array. I For further information, please refer to the "ServerView Suite RAID Management" user guide, available online at Upgrade and Maintenance Manual CX400 S2

107 Hard disk drives / solid state drives Removing a 2.5-inch HDD/SSD module Figure 67: Removing a 2.5-inch HDD/SSD module Undo the locking mechanism of the release lever (1). Swing the release lever in the direction of the arrow (2). Pull out the HDD/SSD module (3). CX400 S2 Upgrade and Maintenance Manual 107

108 Hard disk drives / solid state drives Installing a 2.5-inch HDD/SSD tray V CAUTION! If the removed HDD/SSD module is not replaced immediately, always replace the HDD/SSD tray into the unused HDD/SSD bay to comply with applicable EMC regulations and satisfy cooling requirements. Figure 68: Installing a 2.5-inch HDD/SSD tray Insert the HDD/SSD tray into the drive bay and carefully push back as far as it will go (1). Close the release lever in the direction of the arrow (2). 108 Upgrade and Maintenance Manual CX400 S2

109 Hard disk drives / solid state drives Replacing a 2.5-inch HDD/SSD module Customer Replaceable Units (CRU) Average task duration: 5 minutes V CAUTION! Only remove an HDD/SSD module during operation if the drive is not currently being accessed. Observe the indicators for the corresponding HDD/SSD modules, see "PRIMERGY CX400 S2 Server Enclosure Operating Manual". Under no circumstances should you remove an HDD / SSD module while the system is in operation if you are not sure that the drive is operated by a RAID controller and belongs to a disk array that is operating in RAID level 0, 1, 1E, 10, 5, 50, 6 or 60. An HDD/SSD module can only be replaced during operation in conjunction with a corresponding RAID configuration. All HDD/SSD modules (drives) must be uniquely identified so that they can be reinstalled in their original mounting locations later. If this is not done, existing data can be lost Required tools Preliminary and concluding steps: tool-less Main steps: tool-less Preliminary steps Only applicable for removing intact HDD / SSD modules: Before removing a non-defective HDD/SSD module, put the drive into "Offline" mode using your RAID configuration software Removing a 2.5-inch HDD/SSD module Remove the HDD / SSD module to be replaced from the server as described in section "Removing a 2.5-inch HDD/SSD module" on page 107. CX400 S2 Upgrade and Maintenance Manual 109

110 Hard disk drives / solid state drives Installing a 2.5-inch HDD/SSD module Install the new HDD / SSD module into the empty drive bay as described in section "Installing 2.5-inch HDD/SSD modules" on page Concluding steps Perform the following procedures: "Performing a RAID array rebuild" on page inch hard disk drives HDD install order in the 3.5-inch chassis Figure 69: HDD install order in the 3.5-inch chassis 110 Upgrade and Maintenance Manual CX400 S2

111 Hard disk drives / solid state drives Configuration with standard CPU Figure 70: Configuration with standard CPU Configuration with 130 W (6 core) or 130 W (4 core) CPU support Figure 71: Configuration with 135 W (6 core) or 130 W (4 core) CPU support CX400 S2 Upgrade and Maintenance Manual 111

112 Hard disk drives / solid state drives Installing 3.5-inch HDD modules Customer Replaceable Units (CRU) Average task duration: 5 minutes Required tools Preliminary and concluding steps: tool-less Main steps: tool-less Preliminary steps Perform the following procedures: Locate the correct drive bay as described in section "HDD install order in the 3.5-inch chassis" on page Upgrade and Maintenance Manual CX400 S2

113 Hard disk drives / solid state drives Removing a 3.5-inch HDD tray Figure 72: Removing a 3.5-inch HDD tray I Empty HDD trays have been installed into unused HDD bays. Before installing an additional HDD, the empty HDD tray needs to be removed from the desired drive bay. Undo the locking mechanism of the release lever (1). Swing the release lever in the direction of the arrow (2). Pull out the HDD tray (3). CX400 S2 Upgrade and Maintenance Manual 113

114 Hard disk drives / solid state drives Installing a 3.5-inch HDD module Figure 73: Installing the 3.5-inch HDD module Insert the HDD module into a drive bay and carefully push back as far as it will go (1). Close the release lever in the direction of the arrow (2) Concluding steps Perform the following procedures: "Performing a RAID array rebuild" on page Upgrade and Maintenance Manual CX400 S2

115 Hard disk drives / solid state drives Removing 3.5-inch HDD modules Customer Replaceable Units (CRU) Average task duration: 5 minutes Required tools Preliminary and concluding steps: tool-less Main steps: tool-less Preliminary steps Perform the following procedures: Ensure that the HDD module to be removed is not combined into a RAID array. If the drive is part of a RAID array, you first need to delete the array using ServerView RAID Manager. V CAUTION! All data on all HDDs in the array will be lost! Be sure to back up your data before deleting a RAID array. I For further information, please refer to the "ServerView Suite RAID Management" user guide, available online at CX400 S2 Upgrade and Maintenance Manual 115

116 Hard disk drives / solid state drives Removing a 3.5-inch HDD module Figure 74: Removing a 3.5-inch HDD module Undo the locking mechanism of the release lever (1). Swing the release lever in the direction of the arrow (2). Pull out the HDD module (3). 116 Upgrade and Maintenance Manual CX400 S2

117 Hard disk drives / solid state drives Installing a 3.5-inch HDD tray V CAUTION! If the removed HDD module is not replaced immediately, always replace the HDD tray into the unused HDD bay to comply with applicable EMC regulations and satisfy cooling requirements. Figure 75: Installing a 3.5-inch HDD tray Insert the HDD tray into the drive bay and carefully push back as far as it will go (1). Close the release lever in the direction of the arrow (2). CX400 S2 Upgrade and Maintenance Manual 117

118 Hard disk drives / solid state drives Replacing a 3.5-inch HDD module Customer Replaceable Units (CRU) Average task duration: 5 minutes V CAUTION! Only remove an HDD module during operation if the drive is not currently being accessed. Observe the indicators for the corresponding HDD modules, see "PRIMERGY CX400 S2 Server Enclosure Operating manual". Under no circumstances should you remove an HDD module while the system is in operation if you are not sure that the drive is operated by a RAID controller and belongs to a disk array that is operating in RAID level 0, 1, 1E, 10, 5, 50, 6 or 60. An HDD module can only be replaced during operation in conjunction with a corresponding RAID configuration. All HDD modules (drives) must be uniquely identified so that they can be reinstalled in their original mounting locations later. If this is not done, existing data can be lost Required tools Preliminary and concluding steps: tool-less Main steps: tool-less Preliminary steps Only applicable for removing intact HDD modules: Before removing a non-defective HDD module, put the drive into "Offline" mode using your RAID configuration software. I For further information, please refer to the "ServerView Suite RAID Management" user guide, available online at Upgrade and Maintenance Manual CX400 S2

119 Hard disk drives / solid state drives Removing a 3.5-inch HDD module Remove the HDD module to be replaced from the server as described in section "Removing a 3.5-inch HDD module" on page Installing a 3.5-inch HDD module Install the new HDD module into the empty drive bay as described in section "Installing 3.5-inch HDD modules" on page Concluding steps Perform the following procedures: "Performing a RAID array rebuild" on page 78 CX400 S2 Upgrade and Maintenance Manual 119

120 Hard disk drives / solid state drives 7.4 Replacing HDD/SSD SAS/SATA backplanes Replacing the 2.5-inch HDD/SSD SAS/SATA backplane Field Replaceable Units (FRU) Average hardware task duration: 70 minutes Average software task duration: 5 minutes Note on system information The 2.5-inch HDD/SSD SAS/SATA backplane contains the Chassis ID EPROM that contains system information like server name and model, housing type, serial number and manufacturing data Required tools Preliminary and concluding steps: Phillips PH2 / (+) No. 2 screw driver Main steps: Phillips PH2 / (+) No. 2 screw driver, minimum length 200 mm Preliminary steps Perform the following procedures: "Shutting down the server node" on page 41 "Removing the server enclosure out of the rack" on page 43 V CAUTION! For ALL service tasks, remove the CX400 S2 server enclosure out of the rack and put it on a separate desk! 120 Upgrade and Maintenance Manual CX400 S2

121 Hard disk drives / solid state drives It is not allowed to draw the CX400 S2server enclosure partially out of the rack. "Removing the server node from the server enclosure" on page 48 Remove all HDD/SSD modules as described in section "Removing 2.5-inch HDD/SSD modules" on page 106. "Opening the server enclosure" on page 51 "Removing the power supply module" on page 84 Remove both fan modules as described in section "Removing the fan module" on page 137. "Removing the power distribution module" on page 54 "Removing the midplane" on page 153 Remove all linking boards as described in section "Removing the linking board" on page Adhere plastic film to the 2.5-inch HDD SAS/SATA backplane The plastic film is packed in the carton of the spare parts. You need to adhere the plastic film to HDD SAS/SATA backplane before you install the HDD SAS/SATA backplane. Figure 76: Plastic film for 2.5-inch HDD SAS/SATA backplane Remove the double-stick tape of the plastic film. Adhere the plastic film to the HDD SAS/SATA backplane. CX400 S2 Upgrade and Maintenance Manual 121

122 Hard disk drives / solid state drives Removing the 2.5-inch HDD SAS/SATA backplane Figure 77: Removing the front panel cable from the cable clamps Remove both front panel cables from the cable clamps. Figure 78: Removing the HDD SAS/SATA backplane (A) Note the positions of the shoulder screw caps (1). Remove two screws (2) of the defective HDD SAS/SATA backplane. Figure 79: Removing the HDD SAS/SATA backplane (B) 122 Upgrade and Maintenance Manual CX400 S2

123 Hard disk drives / solid state drives Slide the HDD SAS/SATA backplane in the direction of the arrow (1) as far as it will go. Lift the HDD SAS/SATA backplane out of the chassis (2) Installing the 2.5-inch HDD SAS/SATA backplane Figure 80: Installing the HDD SAS/SATA backplane (A) Note the positions of the shoulder screw caps (1) and the screw holes (2) on the chassis. Figure 81: Installing the HDD SAS/SATA backplane (B) Insert the new HDD SAS/SATA backplane into the chassis (1): The two shoulder screw caps on the chassis rest in the wide end and the center of the keyhole slots on the HDD SAS/SATA backplane. The five noses of the backplane fit behind the guides (see circles). CX400 S2 Upgrade and Maintenance Manual 123

124 Hard disk drives / solid state drives Slide the HDD SAS/SATA backplane in the direction of the arrow as far as it will go (2). Figure 82: Installing the HDD SAS/SATA backplane (C) Secure HDD SAS/SATA backplane with two screws (1). Figure 83: Securing the front panel cable with the cable clamps Secure both front panel cables with the cable clamps Concluding steps Perform the following procedures: Insert all linking boards as described in section "Installing the linking board" on page 162. "Installing the midplane" on page 155 "Installing the power distribution module" on page 57 Install both fan modules as described in section "Installing the fan module" on page Upgrade and Maintenance Manual CX400 S2

125 Hard disk drives / solid state drives "Installing the power supply module" on page 82 "Closing the server enclosure" on page 61 Install all HDD/SSD modules as described in section "Installing 2.5-inch HDD/SSD modules" on page 103. "Installing the server node in the server enclosure" on page 65 "Mounting the server enclosure in the rack" on page 67 "Switching on the server node(s)" on page 75 "Using the Chassis ID Prom Tool" on page 78 CX400 S2 Upgrade and Maintenance Manual 125

126 Hard disk drives / solid state drives Replacing the 3.5-inch HDD SAS/SATA backplane Field Replaceable Units (FRU) Average task duration: 70 minutes Average software task duration: 5 minutes Note on system information The 3.5-inch HDD SAS/SATA backplane contains the Chassis ID EPROM that contains system information like server name and model, housing type, serial number and manufacturing data Required tools Preliminary and concluding steps: Phillips PH2 / (+) No. 2 screw driver Main steps: Phillips PH2 / (+) No. 2 screw driver, minimum length 200 mm Preliminary steps Perform the following procedures: "Shutting down the server node" on page 41 "Removing the server enclosure out of the rack" on page 43 V CAUTION! For ALL service tasks, remove the CX400 S2 server enclosure out of the rack and put it on a separate desk! It is not allowed to draw the CX400 S2server enclosure partially out of the rack. "Removing the server node from the server enclosure" on page Upgrade and Maintenance Manual CX400 S2

127 Hard disk drives / solid state drives Remove all HDD modules as described in section "Removing 3.5-inch HDD modules" on page 115. "Opening the server enclosure" on page 51 "Removing the power supply module" on page 84 Remove both fan modules as described in section "Removing the fan module" on page 137. "Removing the power distribution module" on page 54 "Removing the midplane" on page 153 Remove all linking boards as described in section "Removing the linking board" on page Adhere plastic film to the 3.5-inch HDD SAS/SATA backplane The plastic film is packed in the carton of the spare parts. You need to adhere the plastic film to HDD SAS/SATA backplane before you install the HDD SAS/SATA backplane. Figure 84: Plastic film for 3.5-inch HDD SAS/SATA backplane Remove the double-stick tape of the plastic film. Adhere the plastic film to the HDD SAS/SATA backplane. CX400 S2 Upgrade and Maintenance Manual 127

128 Hard disk drives / solid state drives Removing the 3.5-inch HDD SAS / SATA backplane Figure 85: Removing the front panel cable from the cable clamps Remove both front panel cables from the cable clamps. Figure 86: Removing the HDD SAS/SATA backplane (A) Note the positions of the shoulder screw caps (1). Remove two screws (2) of the defective HDD SAS/SATA backplane. 128 Upgrade and Maintenance Manual CX400 S2

129 Hard disk drives / solid state drives Figure 87: Removing the HDD SAS/SATA backplane (B) Slide the HDD SAS/SATA backplane in the direction of the arrow (1) as far as it will go. Lift the HDD SAS/SATA backplane out of the chassis (2). CX400 S2 Upgrade and Maintenance Manual 129

130 Hard disk drives / solid state drives Installing the 3.5-inch HDD SAS/SATA backplane Figure 88: Installing the HDD SAS/SATA backplane (A) Note the positions of the shoulder screw caps (1) and the screw holes (2) on the chassis. Figure 89: Installing the HDD SAS/SATA backplane (B) Insert the new HDD SAS/SATA backplane into the chassis (1): The two shoulder screw caps on the chassis rest in the wide end and the center of the keyhole slots on the HDD SAS/SATA backplane. The five noses of the backplane fit behind the guides (see circles). Slide the HDD SAS/SATA backplane in the direction of the arrow as far as it will go (2). 130 Upgrade and Maintenance Manual CX400 S2

131 Hard disk drives / solid state drives Figure 90: Installing the HDD SAS/SATA backplane (C) Secure HDD SAS/SATA backplane with two screws (1). Figure 91: Removing the front panel cable from the cable clamps Secure both front panel cables with the cable clamps Concluding steps Perform the following procedures: Insert all linking boards as described in section "Installing the linking board" on page 168. "Installing the midplane" on page 155 "Installing the power distribution module" on page 57 CX400 S2 Upgrade and Maintenance Manual 131

132 Hard disk drives / solid state drives Install both fan modules as described in section "Installing the fan module" on page 147. "Installing the power supply module" on page 82 "Closing the server enclosure" on page 61 Install all HDD/SSD modules as described in section "Installing 3.5-inch HDD modules" on page 112. "Installing the server node in the server enclosure" on page 65 "Mounting the server enclosure in the rack" on page 67 "Switching on the server node(s)" on page 75 "Using the Chassis ID Prom Tool" on page Upgrade and Maintenance Manual CX400 S2

133 8 System fan Safety notes V CAUTION! Do not damage or modify internal cables or devices. Doing so may cause a device failure, fire, or electric shock. Devices and components inside the server remain hot after shutdown. After shutting down the server, wait for hot components to cool down before installing or removing internal options. Circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. Always discharge static build-up (e.g. by touching a grounded object) before handling electrostaticsensitive devices (ESDs). Do not touch the circuitry on boards or soldered parts. Hold circuit boards by their metallic areas or edges. If devices are installed or disassembled using methods other than those outlined in this chapter, the warranty will be invalidated. For further information, please refer to chapter "Important information" on page 31. CX400 S2 Upgrade and Maintenance Manual 133

134 System fan 8.1 Basic Information The PRIMERGY CX400 S2 server features four non hot-plug fans. Two fans each are combined in a fan module. Fan positions The figure 92 shows the position of the system fans 1 to 4. Figure 92: Fan positions 134 Upgrade and Maintenance Manual CX400 S2

135 System fan Connectors on the PDB The figure 93 shows the connectors on the PDBs for the system fans 1 to 4. Figure 93: Connectors on the PDBs top PDB bottom PDB Top PDB Bottom PDB 1 J3 J3 2 J4 J4 3 FAN1 (J8) FAN3 (J8) 4 FAN2 (J9) FAN4 (J9) Fan1 and fan2 are connected to the top PDB. Fan3 and fan4 are connected to the bottom PDB. Cable Fan1-5 C3 Fan2-6 Fan3-7 C3 Fan4-8 Table 6: Fan cabling Connector on the PDB FAN1 (J8) and J3, top PDB FAN2 (J9) and J4, top PDB FAN3 (J8) and J3, bottom PDB FAN4 (J9) and J4, bottom PDB CX400 S2 Upgrade and Maintenance Manual 135

136 System fan 8.2 Replacing the fan in the fan module Field Replaceable Units (FRU) Average task duration: 20 minutes Required tools Preliminary and concluding steps: Phillips PH2 / (+) No. 2 screw driver Main steps: Phillips PH2 / (+) No. 2 screw driver Preliminary steps Perform the following procedures: "Shutting down the server node" on page 41 "Removing the server enclosure out of the rack" on page 43 V CAUTION! For ALL service tasks, remove the CX400 S2 server enclosure out of the rack and put it on a separate desk! It is not allowed to draw the CX400 S2server enclosure partially out of the rack. "Removing the server node from the server enclosure" on page 48 "Opening the server enclosure" on page Upgrade and Maintenance Manual CX400 S2

137 System fan Removing the fan module I There are available two different kinds of fan modules: fan module without detachable cable fan module with detachable cable Follow the appropriate procedure described in the sections "Fan without detachable cable" on page 137 or "Fan with detachable cable" on page 138. Fan without detachable cable Figure 94: Removing the fan module (A) Disconnect the fan cables from the corresponding PDB: For fan1 and fan2 from the top PDB (1) For fan3 and fan4 from the bottom PDB (2) Thread the fan cables carefully through the recess (3). CX400 S2 Upgrade and Maintenance Manual 137

138 System fan Fan with detachable cable Figure 95: Fan with detachable cable I Fans will now be replaced by fans with detachable cable. There will be no change of product number. Figure 96: Detachable cable of fan I Disconnecting the cables from the top PDB and from the bottom PDB is now unnecessary! Just detach the cable from the connector and carefully thread the fan cable through the recess. 138 Upgrade and Maintenance Manual CX400 S2

139 System fan Figure 97: Removing the fan module (B) Remove four screws. Carefully lift the fan module out of the chassis. V CAUTION! Ensure not to strain the fan cables! Replace the defective fan as described in section "Replacing the fan in the fan module" on page Removing the fan from the fan holder I If you want replace fan1, you have to remove fan2 before. If you want replace fan4, you have to remove fan3 before. CX400 S2 Upgrade and Maintenance Manual 139

140 System fan Fan 1 Fan 2 Figure 98: Removing the fan from the fan holder Remove four screws. Remove the fan out of the fan holder (1). 140 Upgrade and Maintenance Manual CX400 S2

141 System fan Installing fan1 and fan2 Figure 99: Air flow direction I Take note of the air flow direction. CX400 S2 Upgrade and Maintenance Manual 141

142 System fan Installing the fan1 air flow Figure 100: Installing fan1 in the fan holder Insert fan1 in the left part of the fan holder (1). I Take note of the air flow direction (2). Run the fan cable along the bottom of the fan holder (3). Pull the fan cable through the recess on the right side (4). Secure the fan with four screws. 142 Upgrade and Maintenance Manual CX400 S2

143 System fan Installing the fan2 air flow Figure 101: Installing fan2 in the fan holder Insert fan2 in the right part of the fan holder (1). I Take note of the air flow direction (2). Pull the fan1 cable to ensure not to be interfered with fan2 (3). Secure the fan with four screws. CX400 S2 Upgrade and Maintenance Manual 143

144 System fan Installing fan3 and fan4 Figure 102: Air flow direction I Take note of the air flow direction. 144 Upgrade and Maintenance Manual CX400 S2

145 System fan Installing the fan4 air flow Figure 103: Installing fan4 in the fan holder Insert fan4 in the right part of the fan holder (1). I Take note of the air flow direction (2). Run the fan cable along the bottom of the fan holder (3). Pull the fan cable through the recess on the left side (4). Secure the fan with four screws. CX400 S2 Upgrade and Maintenance Manual 145

146 System fan Installing the fan3 air flow Figure 104: Installing fan3 in the fan holder Insert fan3 in the left part of the fan holder (1). I Take note of the air flow direction (2). Pull the fan4 cable to ensure not to be interfered with fan3 (3). Secure the fan with four screws. 146 Upgrade and Maintenance Manual CX400 S2

147 System fan Installing the fan module I There are available two different kinds of fan modules: fan module without detachable cable fan module with detachable cable Follow the appropriate procedure described in the sections "Fan module without detachable cable" on page 148 or "Fan with detachable cable" on page 148. Fan1-5 Fan2-6 Fan3-7 Fan4-8 Figure 105: Installing the fan module Insert the fan module into its slot. Ensure that the fan module is properly seated in the chassis. Secure each fan module with four screws. CX400 S2 Upgrade and Maintenance Manual 147

148 System fan Fan module without detachable cable Figure 106: Removing the fan module (A) Thread the fan cables carefully through the recess (1). Connect the fan cables to the corresponding PDB, see also "Basic Information" on page 134: For fan1 and fan2 to the top PDB (2) For fan3 and fan4 to the bottom PDB (3) Fan with detachable cable Figure 107: Fan with detachable cable 148 Upgrade and Maintenance Manual CX400 S2

149 System fan I Fans will now be replaced by fans with detachable cable. There will be no change of product number. Figure 108: Detachable cable of fan I Connecting the cables to the top PDB and to the bottom PDB is now unnecessary! Carefully thread the fan cable through the recess and connect the cable to the connector. CX400 S2 Upgrade and Maintenance Manual 149

150 System fan Concluding steps Perform the following procedures: "Closing the server enclosure" on page 61 "Installing the server node in the server enclosure" on page 65 "Mounting the server enclosure in the rack" on page 67 "Switching on the server node(s)" on page Upgrade and Maintenance Manual CX400 S2

151 9 Midplane Safety notes V CAUTION! Do not damage or modify internal cables or devices. Doing so may cause a device failure, fire, or electric shock. Devices and components inside the server remain hot after shutdown. After shutting down the server, wait for hot components to cool down before installing or removing internal options. Circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. Always discharge static build-up (e.g. by touching a grounded object) before handling electrostaticsensitive devices (ESDs). Do not touch the circuitry on boards or soldered parts. Hold circuit boards by their metallic areas or edges. If devices are installed or disassembled using methods other than those outlined in this chapter, the warranty will be invalidated. For further information, please refer to chapter "Important information" on page 31. CX400 S2 Upgrade and Maintenance Manual 151

152 Midplane 9.1 Replacing the midplane I The following description is also valid for the midplane with expander. Field Replaceable Units (FRU) Average task duration: 45 minutes Required tools Preliminary and concluding steps: Phillips PH2 / (+) No. 2 screw driver Main steps: Phillips PH2 / (+) No. 2 screw driver Preliminary steps Perform the following procedures: "Shutting down the server node" on page 41 "Removing the server enclosure out of the rack" on page 43 V CAUTION! For ALL service tasks, remove the CX400 S2 server enclosure out of the rack and put it on a separate desk! It is not allowed to draw the CX400 S2server enclosure partially out of the rack. "Removing the server node from the server enclosure" on page 48 "Opening the server enclosure" on page 51 "Removing the power supply module" on page 84 "Removing the power distribution module" on page Upgrade and Maintenance Manual CX400 S2

153 Midplane Removing the midplane Figure 109: Removing the air duct Detach the right and the left side of the adhesive air duct by pressing it inwards (1). Remove the air duct in the direction of the arrow (2). CX400 S2 Upgrade and Maintenance Manual 153

154 Midplane Figure 110: Disconnecting the front panel cable Disconnect both front panel cables from the rear of the midplane. Figure 111: Removing the midplane Remove ten screws from the midplane (see circles). Remove the midplane (1). 154 Upgrade and Maintenance Manual CX400 S2

155 Midplane Installing the midplane Figure 112: Positions of the centering bolts Note of the positions of the centering bolts in the chassis. Figure 113: Mounting the midplane (A) Insert the midplane (1) onto the centering bolts (2). Ensure that the midplane is properly seated on both centering bolts. Ensure that the linking boards are properly connected with the connectors on the midplane. CX400 S2 Upgrade and Maintenance Manual 155

156 Midplane Figure 114: Mounting the midplane (B) Secure the midplane with ten screws (see circles). Figure 115: Connecting the front panel cables Connect the right front panel cable to the right connector on the rear of the midplane (1). Connect the left front panel cable to the left connector on the rear of the midplane (2). 156 Upgrade and Maintenance Manual CX400 S2

157 Midplane Figure 116: Midplane air duct Note the direction of the air duct. Figure 117: Installing the air duct Insert the air duct in the direction of the arrow (1). Attach the right and the left side of the air duct to the adhesive tapes on the chassis by pressing it outwards (2). CX400 S2 Upgrade and Maintenance Manual 157

158 Midplane Concluding steps Perform the following procedures: "Installing the power distribution module" on page 57 "Installing the power supply module" on page 82 "Closing the server enclosure" on page 61 "Installing the server node in the server enclosure" on page 65 "Mounting the server enclosure in the rack" on page 67 "Switching on the server node(s)" on page Upgrade and Maintenance Manual CX400 S2

159 10 Linking boards Safety V CAUTION! Do not damage or modify internal cables or devices. Doing so may cause a device failure, fire, or electric shock. Devices and components inside the server remain hot after shutdown. After shutting down the server, wait for hot components to cool down before installing or removing internal options. Circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. Always discharge static build-up (e.g. by touching a grounded object) before handling electrostaticsensitive devices (ESDs). Do not touch the circuitry on boards or soldered parts. Hold circuit boards by their metallic areas or edges. If devices are installed or disassembled using methods other than those outlined in this chapter, the warranty will be invalidated. For further information, please refer to chapter "Important information" on page Linking boards in 2.5-inch HDD chassis Basic Information The chassis for 2.5" HDD is equipped with four different linking boards. CX400 S2 Upgrade and Maintenance Manual 159

160 Linking boards Figure 118: Positions of the linking boards chassis 2.5" HDD Pos. Description Part number 1 Linking/B-1 A3C KS2HLB Linking/B-2 A3C KS2HLB Linking/B-3 A3C KS2HLB Linking/B-4 A3C KS2HLB Replacing the linking board Field Replaceable Units (FRU) Average task duration: 55 minutes 160 Upgrade and Maintenance Manual CX400 S2

161 Linking boards Required tools Preliminary and concluding steps: Phillips PH2 / (+) No. 2 screw driver Main steps: Phillips PH2 / (+) No. 2 screw driver Preliminary steps Perform the following procedures: "Shutting down the server node" on page 41 "Removing the server enclosure out of the rack" on page 43 V CAUTION! For ALL service tasks, remove the CX400 S2 server enclosure out of the rack and put it on a separate desk! It is not allowed to draw the CX400 S2server enclosure partially out of the rack. "Removing the server node from the server enclosure" on page 48 "Opening the server enclosure" on page 51 "Removing the power supply module" on page 84 Remove both fan modules as described in section "Removing the fan module" on page 137. "Removing the power distribution module" on page 54 "Removing the midplane" on page Removing the linking board I Take note of the linking board position! CX400 S2 Upgrade and Maintenance Manual 161

162 Linking boards Figure 119: Removing the linking board Slide the linking board in the direction of the arrow as far as it will go (1). The linking board will be disconnected from the HDD backplane (2). Lift the linking board out of the chassis (3) Installing the linking board Select the corresponding linking board, see figure 118 on page 160. Figure 120: Board number and mounting direction of the linking board Note the board number (1) and the mounting direction (2) of the linking board. 162 Upgrade and Maintenance Manual CX400 S2

163 Linking boards Figure 121: Installing the linking board (A) Note the positions of the shoulder screw caps on the chassis. Insert the linking board into the chassis so that the two shoulder screw caps on the chassis rest in the wide ends of the keyhole slots on the linking board. Figure 122: Installing the linking board (B) Slide the linking board to the left as far as it will go (1). The linking board will be connected to the HDD backplane (2). CX400 S2 Upgrade and Maintenance Manual 163

164 Linking boards Concluding steps Perform the following procedures: "Installing the midplane" on page 155 "Installing the power distribution module" on page 57 Install both fan modules as described in section "Installing the fan module" on page 147. "Installing the power supply module" on page 82 "Closing the server enclosure" on page 61 "Installing the server node in the server enclosure" on page 65 "Mounting the server enclosure in the rack" on page 67 "Switching on the server node(s)" on page Upgrade and Maintenance Manual CX400 S2

165 Linking boards 10.2 Linking boards in 3.5-inch HDD chassis Basic information The chassis for 3.5" HDD is equipped with two different linking boards. Figure 123: Positions of the linking boards chassis 3.5" HDD Pos. Description Part number 1 Linking/B-1 A3C IS2HLB Linking/B-2 A3C IS2HLB0030 CX400 S2 Upgrade and Maintenance Manual 165

166 Linking boards Replacing the linking board Field Replaceable Units (FRU) Average task duration: 55 minutes Required tools Preliminary and concluding steps: Phillips PH2 / (+) No. 2 screw driver Main steps: Phillips PH2 / (+) No. 2 screw driver Preliminary steps Perform the following procedures: "Shutting down the server node" on page 41 "Removing the server enclosure out of the rack" on page 43 V CAUTION! For ALL service tasks, remove the CX400 S2 server enclosure out of the rack and put it on a separate desk! It is not allowed to draw the CX400 S2server enclosure partially out of the rack. "Removing the server node from the server enclosure" on page 48 "Opening the server enclosure" on page 51 "Removing the power supply module" on page 84 Remove both fan modules as described in section "Removing the fan module" on page 137. "Removing the power distribution module" on page 54 "Removing the midplane" on page Upgrade and Maintenance Manual CX400 S2

167 Linking boards Removing the linking board Figure 124: Removing the linking board Slide the linking board in the direction of the arrow as far as it will go (1). The linking board will be disconnected from the HDD backplane (2). Lift the linking board out of the chassis (3). CX400 S2 Upgrade and Maintenance Manual 167

168 Linking boards Installing the linking board Figure 125: Board number and mounting direction of the linking board Note the board number (1) and the mounting direction (2) of the linking board. Figure 126: Positions of the shoulder screw caps on the chassis Note the positions of the shoulder screw caps on the chassis. 168 Upgrade and Maintenance Manual CX400 S2

169 Linking boards Figure 127: Installing the linking board (A) Insert the linking board into the chassis so that the two shoulder screw caps on the chassis rest in the wide ends of the keyhole slots on the linking board. Figure 128: Installing the linking board (B) Slide the linking board in the direction of the arrow as far as it will go (1). The linking board will be connected to the HDD backplane (2). CX400 S2 Upgrade and Maintenance Manual 169

170 Linking boards Concluding steps Perform the following procedures: "Installing the midplane" on page 155 "Installing the power distribution module" on page 57 Install both fan modules as described in section "Installing the fan module" on page 147. "Installing the power supply module" on page 82 "Closing the server enclosure" on page 61 "Installing the server node in the server enclosure" on page 65 "Mounting the server enclosure in the rack" on page 67 "Switching on the server node(s)" on page Upgrade and Maintenance Manual CX400 S2

171 11 Front panel Safety notes V CAUTION! When inserting the front panel module into the server, ensure not to pinch or strain any connected cables. Circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. Always discharge static build-up (e.g. by touching a grounded object) before handling electrostaticsensitive devices (ESDs) Do not touch the circuitry on boards or soldered parts. Hold circuit boards by their metallic areas or edges. For further information, please refer to chapter "Important information" on page 31. CX400 S2 Upgrade and Maintenance Manual 171

172 Front panel 11.1 Replacing the front panel board Field Replaceable Units (FRU) Average hardware task duration: 10 minutes Required tools Preliminary and concluding steps: tool-less Main steps: Phillips PH2 / (+) No. 2 screw driver Preliminary steps Perform the following procedures: "Shutting down the server node" on page 41 "Removing the server enclosure out of the rack" on page 43 V CAUTION! For ALL service tasks, remove the CX400 S2 server enclosure out of the rack and put it on a separate desk! It is not allowed to draw the CX400 S2server enclosure partially out of the rack. 172 Upgrade and Maintenance Manual CX400 S2

173 Front panel Removing the front ear bracket Figure 129: Removing the front ear bracket Remove the feature (1) under the bezel hook. Remove the metal sheet by removing the two screws (2). Figure 130: Spacer (metal sheet) CX400 S2 Upgrade and Maintenance Manual 173

174 Front panel Removing the front panel board Figure 131: Removing the front panel cover (A) Remove the screw if there is no front ear bracket (see section "Removing the front ear bracket" on page 173). 174 Upgrade and Maintenance Manual CX400 S2

175 Front panel Figure 132: Removing the front panel cover (B) Remove the front panel cover. CX400 S2 Upgrade and Maintenance Manual 175

176 Front panel Figure 133: Removing the front panel board Remove the screw (1) and disengage the front panel board (2). 176 Upgrade and Maintenance Manual CX400 S2

177 Front panel Figure 134: Disconnecting the front panel cable Disconnect the front panel cable from the front panel module. CX400 S2 Upgrade and Maintenance Manual 177

178 Front panel Installing the front panel board Figure 135: Connecting the front panel cable - left side Connect the front panel cable to the front panel module as shown. 178 Upgrade and Maintenance Manual CX400 S2

179 Front panel Figure 136: Connecting the front panel cable - right side On the right side, fold the cable in the direction of the arrow. CX400 S2 Upgrade and Maintenance Manual 179

180 Front panel Figure 137: Installing the front panel board Place the front panel board: The recess on the top will be secured with the screw (1) and the hook on the bottom must fit with the recess (2). V CAUTION! Ensure that none of the cables are strained or damaged! Ensure that the four small button covers are properly seated. 180 Upgrade and Maintenance Manual CX400 S2

181 Front panel Figure 138: Installing the front panel cover (A) Install the front panel cover. CX400 S2 Upgrade and Maintenance Manual 181

182 Front panel Figure 139: Installing the front panel cover (B) Secure the front panel cover with one screw if there is no front ear bracket (see section"installing the front ear bracket" on page 183). 182 Upgrade and Maintenance Manual CX400 S2

183 Front panel Installing the front ear bracket Figure 140: Installing the front ear bracket Insert the feature (1) under the bezel hook to prevent bezel peer off. Fix the metal sheet with the two screws (2). Figure 141: Spacer (metal sheet) CX400 S2 Upgrade and Maintenance Manual 183

184 Front panel Concluding steps Perform the following procedures: "Mounting the server enclosure in the rack" on page 67 "Switching on the server node(s)" on page Upgrade and Maintenance Manual CX400 S2

185 Front panel 11.2 Replacing the front panel cable Field Replaceable Units (FRU) Average hardware task duration: 80 minutes Required tools Preliminary and concluding steps: tool-less Main steps: Phillips PH2 / (+) No. 2 screw driver Preliminary steps Perform the following procedures: "Shutting down the server node" on page 41 "Removing the server enclosure out of the rack" on page 43 V CAUTION! For ALL service tasks, remove the CX400 S2 server enclosure out of the rack and put it on a separate desk! It is not allowed to draw the CX400 S2server enclosure partially out of the rack. "Removing the server node from the server enclosure" on page 48 Remove all HDD/SSD modules as described in section "Removing 2.5-inch HDD/SSD modules" on page 106 (if applicable) Remove all HDD modules as described in section "Removing 3.5-inch HDD modules" on page 115 (if applicable) "Opening the server enclosure" on page 51 "Removing the power supply module" on page 84 Remove both fan modules as described in section "Removing the fan module" on page 137. CX400 S2 Upgrade and Maintenance Manual 185

186 Front panel "Removing the power distribution module" on page 54 "Removing the midplane" on page 153 Remove all linking boards for 2.5-inch HDDas described in section"removing the linking board" on page 161 (if applicable). Remove all linking boards for 3.5-inch HDDas described in section "Removing the linking board" on page 167 (if applicable). "Removing the 2.5-inch HDD SAS/SATA backplane" on page 122 (if applicable) "Removing the 3.5-inch HDD SAS / SATA backplane" on page 128 (if applicable) "Removing the front panel board" on page Upgrade and Maintenance Manual CX400 S2

187 Front panel Removing the front panel cable Figure 142: Removing the front panel cable Slide the front panel cable over the standoffs (1, 2) to remove the front panel cable. V CAUTION! Ensure that none of the cables are strained or damaged! CX400 S2 Upgrade and Maintenance Manual 187

188 Front panel Installing the front panel cable Figure 143: Installing front panel cable (A) Use a thin cable noose (thickness under 1.0 mm) to route the front panel cable. Figure 144: Installing front panel cable (B) Insert the cable (1), while following the cable routing. The cable must be run over the standoff (2) and then under the standoff (3). 188 Upgrade and Maintenance Manual CX400 S2

189 Front panel Routing of the front panel cable Figure 145: Routing of the front panel cable Concluding steps Perform the following procedures: "Installing the front panel board" on page 178 "Installing the 2.5-inch HDD SAS/SATA backplane" on page 123 (if applicable) "Installing the 3.5-inch HDD SAS/SATA backplane" on page 130 (if applicable) Install all linking boards for 2.5-inch HDDas described in section "Installing the linking board" on page 162 (if applicable). Install all linking boards for 3.5-inch HDDas described in section "Installing the linking board" on page 168 (if applicable). "Installing the midplane" on page 155 "Installing the power distribution module" on page 57 CX400 S2 Upgrade and Maintenance Manual 189

190 Front panel "Installing the power supply module" on page 82 Install both fan modules as described in section "Installing the fan module" on page 147. "Closing the server enclosure" on page 61 Install all HDD/SSD modules as described in section "Installing 2.5-inch HDD/SSD modules" on page 103 (if applicable) Install all HDD modules as described in section "Installing 3.5-inch HDD modules" on page 112 (if applicable) "Installing the server node in the server enclosure" on page 65 "Mounting the server enclosure in the rack" on page 67 "Switching on the server node(s)" on page Upgrade and Maintenance Manual CX400 S2

191 12 Cabling Safety notes V CAUTION! Always hold cables by their connectors when disconnecting them. Never pull on the cable to disconnect cables. Ensure that none of the cables are scraped, strained or otherwise damaged while replacing system components. Immediately replace cables with damaged shielding. Always use shielded network cables Cabling overview I The part number of the cables can be the first or the second one. No. Part number Type Description C1 DD0S2HPB201 Power from HDD BP to top PDB C2 DD0S2HPB501 Power from HDD BP to bottom PDB C3 DQ5DC88P003 Fan cable from fan to top/bottom PDB * C4 DD0S2HTH501 I2C from midplane to top/bottom PDB C5 DD0S2HTH000 Front panel from front panel to Midplane C6 DD0S2HPB411 Power from midplane to top PDB C7 DD0S2HPB311 Power from midplane to bottom PDB C8 DD0S2HPB701 Power from HDD BP to top PDB C9 DD0S2LTH800 Power from HDD BP to top PDB Table 7: List of used cables * (C3): There are two possible types of this cable (see also chapter "Fan with detachable cable" on page 138): without detachable cable: Two connectors for top/bottom PDB are connected to the cable of the fan directly. CX400 S2 Upgrade and Maintenance Manual 191

192 Cabling with detachable cable: Cable with two connectors for top/bottom PDB is detachable from the fan Cabling Figure 146: 2.5-inch chassis 192 Upgrade and Maintenance Manual CX400 S2

193 Cabling Figure 147: 3.5-inch chassis CX400 S2 Upgrade and Maintenance Manual 193

194 Cabling 12.3 Connectors on the boards Figure 148: Top PDB 1 J3 2 J4 3 FAN1 (J8) 4 FAN2 (J9) 5 J2 6 MB1_PWR_CONN 7 MB2_PWR_CONN 8 BP PWR CONN 194 Upgrade and Maintenance Manual CX400 S2

195 Cabling Figure 149: Bottom PDB 1 J3 2 J4 3 FAN3 (J8) 4 FAN4 (J9) 5 J2 6 MB3_PWR_CONN 7 MB4_PWR_CONN 8 BP PWR CONN 9 J10 - connector for the Top PDB CX400 S2 Upgrade and Maintenance Manual 195

196 Cabling Figure 150: Midplane 1 MB1 2 MB2 3 J14 4 J16 5 MB4 6 MB3 7 J15 8 J Upgrade and Maintenance Manual CX400 S2

197 Cabling Figure 151: 2.5-inch HDD/SSD backplane 1 PWR CONN PWR CONN Linking board 4 Linking board 5 Linking board 6 Linking board CX400 S2 Upgrade and Maintenance Manual 197

198 Cabling 198 Upgrade and Maintenance Manual CX400 S2

199 13 Appendix 13.1 Mechanical overview Multi-node server system front 2.5 inch HDD/SSD model Figure 152: PRIMERGY CX400 S2 front inch HDD/SSD model With CX250 S2 server nodes Pos. Component 1 Front panel module for server node 1 2 Front panel module for server node 2 3 Front panel module for server node 3 4 Front panel module for server node x 2.5-inch hard disk drives / trays With CX270 S2 server nodes Pos. Component 2 Front panel module for server node 1 4 Front panel module for server node x 2.5-inch hard disk drives / trays CX400 S2 Upgrade and Maintenance Manual 199

200 Appendix Multi-node server system front 3.5 inch HDD model Figure 153: PRIMERGY CX400 S2 front inch HDD model With CX250 S2 server nodes Pos. Component 1 Front panel module for server node 1 2 Front panel module for server node 2 3 Front panel module for server node 3 4 Front panel module for server node x 3.5-inch hard disk drives / trays With CX270 S2 server nodes Pos. Component 2 Front panel module for server node 1 4 Front panel module for server node x 3.5-inch hard disk drives / trays 200 Upgrade and Maintenance Manual CX400 S2

201 Appendix Multi-node server system rear CX400 S2 server enclosure with CX250 S2 server nodes Figure 154: PRIMERGY CX400 S2 server enclosure rear with CX250 S2 server nodes Pos. Component 1 Installation bay 1 for CX250 S2 server nodes 2 Installation bay 2 for CX250 S2 server nodes 3 Installation bay 3 for CX250 S2 server nodes 4 Installation bay 4 for CX250 S2 server nodes 5 Installation bay 1 for PSU 6 Installation bay 2 for PSU CX400 S2 Upgrade and Maintenance Manual 201

202 Appendix CX400 S2 server enclosure with CX270 S2 server nodes Figure 155: PRIMERGY CX400 S2 server enclosure rear with CX270 S2 server nodes Pos. Component 1 Installation bay 1 for CX270 S2 server nodes 2 Installation bay 2 for CX270 S2 server nodes 3 Installation bay 1 for PSU 4 Installation bay 2 for PSU 202 Upgrade and Maintenance Manual CX400 S2

203 Appendix Multi-node server system interior inch HDD/SSD model Figure 156: PRIMERGY CX400 S2 interior inch HDD/SSD model Pos. Component 1 24x 2.5-inch hard disk drives / trays 2 2 front panel modules 3 HDD backplane (not visible) 4 2 fan modules 5 midplane 6 Up to 4x CX250 S2 or 2x CX270 S2 7 Power distribution module 8 Up to 2 power supply modules CX400 S2 Upgrade and Maintenance Manual 203

204 Appendix inch HDD model Figure 157: PRIMERGY CX400 S2 interior inch HDD model Pos. Component 1 12x 3.5-inch hard disk drives / trays 2 2 front panel modules 3 HDD backplane (not visible) 4 2 fan modules 5 midplane 6 Up to 4x CX250 S2 or 2x CX270 S2 7 Power distribution module 8 Up to 2 power supply modules 204 Upgrade and Maintenance Manual CX400 S2

205 Appendix 13.2 Controls and indicators Front panel Figure 158: Controls and indicators on the front panel Pos. Component 1 On/Off button / Power-on indicator 2 ID button / ID indicator CX400 S2 Upgrade and Maintenance Manual 205

206 Appendix Controls on the front panel On/Off button When the system is switched off, it can be switched on again by pressing the On/Off button. When the system is operating, pressing the On/Off button will switch off the system. V CAUTION! Risk of loss of data! I The On/Off button does not disconnect the multi-node server system from the mains voltage. To disconnect from the mains completely, remove the power plug(s). ID ID button Lights up (blue) on the front and on the rear of the server when the ID button is pressed. Both ID indicators are synchronized Indicators on the front panel No. Function Status Description 1 Power-on Green LED: on Power on indicator Green LED: off Power off Orange LED flashing Power off and fault Green/Orange LED: Power on and fault alternate flashing 2 ID Blue LED: flashing Select mode indicator Blue LED: off Normal mode 206 Upgrade and Maintenance Manual CX400 S2

207 Appendix Hard disk drives Indicators on the hard disk drives Figure 159: Indicators on the 3.5-inch HDD (A) and on the 2.5-inch HDD/SSD modules (B) 1 Slot/RAID status indicator Does not light: HDD/SSD does not exist Lit (green): HDD/SSD exist Lit (red): HDD/SSD Faulty (drive defective, needs replacing) Flashing (orange/red): HDD/SSD Rebuild (the data is being restored after changing a drive) Lit (orange): HDD/SSD Identify 2 HDD/SSD activity indicator (green) Lit: HDD/SSD in active phase (drive active, drive being accessed) Does not light: HDD/SSD inactive CX400 S2 Upgrade and Maintenance Manual 207

208 Appendix Power supply module Indicator on hot-plug power supply module Figure 160: Indicator on hot-plug PSU 1 Indicator on hot-plug PSU (two colors) Lights up green when the server enclosure is switched on and functioning properly. Lights up yellow if the PSU has failed Server nodes I The controls and indicators of the server nodes are described in the corresponding Operating or Upgrade and Maintenance manuals, see "Documents for the server nodes" on page Upgrade and Maintenance Manual CX400 S2

209 Appendix 13.3 Minimum startup configuration Field Replaceable Units (FRU) If the server does not start up or other problems occur, it may be necessary to take the system down to its most basic configuration in order to isolate the defective component. The minimum startup configuration consists of the following components and cables: Component 1 Server node CX250 S2 or CX270 S2 1 PSU Notes and reference Table 8: Minimum startup configuration - components Cable Notes and reference Power cable Table 9: Minimum startup configuration - cables Shut down the server as described in section "Shutting down the server node" on page 41. Remove the AC power cord from the cable tie and disconnect it from the system as described in section "Disconnecting the power cord" on page 42. Take the system down to its minimum startup configuration. Reconnect the AC power cord to the power supply module and secure it with a cable tie as described in section "Connecting the power cord" on page 73. Switch on the server as described in section "Switching on the server node(s)" on page 75. V CAUTION! Since the fan module is not included in the minimum startup configuration, the server must be shut down immediately after the diagnostic process is complete (POST phase has been passed). CX400 S2 Upgrade and Maintenance Manual 209

210 Appendix The minimum startup configuration must be used exclusively for diagnostic purposes by maintenance personnel, never in daily operation! 210 Upgrade and Maintenance Manual CX400 S2

FUJITSU Server PRIMERGY RX1330 M2

FUJITSU Server PRIMERGY RX1330 M2 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX1330 M2 Upgrade and Maintenance Manual December 2015 Comments Suggestions Corrections The User Documentation Department would like to

More information

PRIMERGY RX200 S8 Server

PRIMERGY RX200 S8 Server Upgrade and Maintenance Manual - English PRIMERGY RX200 S8 Server Upgrade and Maintenance Manual June 2015 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

PRIMERGY TX100 S3 Server

PRIMERGY TX100 S3 Server Upgrade and Maintenance Manual - English PRIMERGY TX100 S3 Server Upgrade and Maintenance Manual February 2014 Comments Suggestions Corrections The User Documentation Department would like to know your

More information

PRIMERGY TX100 S1. Options Guide

PRIMERGY TX100 S1. Options Guide PRIMERGY TX100 S1 Options Guide Edition August 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our

More information

PRIMERGY BX620 S6 Server Blade

PRIMERGY BX620 S6 Server Blade Options Guide - English PRIMERGY BX620 S6 Server Blade Options Guide August 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC)

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC) User Guide - English FUJITSU Software ServerView Suite Local Service Panels Local Service Concept (LSC) Edition February 2013 Comments Suggestions Corrections The User Documentation Department would like

More information

HP SuperSpeed USB 3.0 PCIe x1 Card. User Guide

HP SuperSpeed USB 3.0 PCIe x1 Card. User Guide HP SuperSpeed USB 3.0 PCIe x1 Card User Guide Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and Windows

More information

FUJITSU Server PRIMERGY CX2550 M2 Server Node

FUJITSU Server PRIMERGY CX2550 M2 Server Node Operating Manual - English FUJITSU Server PRIMERGY CX2550 M2 Server Node Operating Manual Edition November 2015 Comments Suggestions Corrections The User Documentation Department would like to know your

More information

System Board D2779 for PRIMERGY TX100 S2

System Board D2779 for PRIMERGY TX100 S2 Technical Manual - English System Board D2779 for PRIMERGY TX100 S2 Technical Manual Edition June 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

System Board D3009 for PRIMERGY TX100 S3

System Board D3009 for PRIMERGY TX100 S3 Technical Manual - English System Board D3009 for PRIMERGY TX100 S3 Technical Manual Edition May 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

Installation Guide. Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit. Issue: 022808 PN: 883884-07L Rev. A

Installation Guide. Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit. Issue: 022808 PN: 883884-07L Rev. A Installation Guide Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit Issue: 022808 PN: 883884-07L Rev. A ii Copyright Notice 2008, Wyse Technology Inc. All rights reserved. This manual and the

More information

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Scale-Out Smart for HPC, Cloud and Hyper-Converged Computing

More information

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server High availability for lower expertise

More information

Options Guide - English PRIMERGY TX100 S2. Options Guide

Options Guide - English PRIMERGY TX100 S2. Options Guide Options Guide - English PRIMERGY TX100 S2 Options Guide July 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

Removable 2.5 SATA HDD Backup System

Removable 2.5 SATA HDD Backup System Removable 2.5 SATA HDD Backup System SAT2510U3REM SAT2510U3S *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario

More information

2 Bay USB 3.0 RAID 3.5in HDD Enclosure

2 Bay USB 3.0 RAID 3.5in HDD Enclosure 2 Bay USB 3.0 RAID 3.5in HDD Enclosure SAT3520U3SR *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario - es.startech.com

More information

Power Supply Guide Version 1.0 for D-Show

Power Supply Guide Version 1.0 for D-Show Power Supply Guide Version 1.0 for D-Show Digidesign 2001 Junipero Serra Boulevard Daly City, CA 94014-3886 USA tel: 650 731 6300 fax: 650 731 6399 Technical Support (USA) tel: 650 731 6100 fax: 650 731

More information

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure Scale-Out Smart for HPC and Cloud Computing with enhanced energy efficiency The PRIMERGY CX400 Cloud extension servers are Fujitsu

More information

PRIMERGY RX600 S6 Server

PRIMERGY RX600 S6 Server Operating Manual - English PRIMERGY RX600 S6 Server Operating Manual July 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback

More information

PRIMERGY RX100 S6 Server. Operating manual

PRIMERGY RX100 S6 Server. Operating manual PRIMERGY RX100 S6 Server Operating manual April 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our

More information

HP SATA/SAS hard drive and Solid State Drive installation

HP SATA/SAS hard drive and Solid State Drive installation HP SATA/SAS hard drive and Solid State Drive installation This document describes how to install Serial ATA (SATA) and Serial Attached SCSI (SAS) hard drives or Solid State Drives (SSD) in an internal

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

PRIMERGY SX960 S1 Storage Blade

PRIMERGY SX960 S1 Storage Blade Operating Manual - English PRIMERGY SX960 S1 Storage Blade Operating Manual April 2014 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

4x3.5" Hot-Swap Drive Cage Kit Installation Guide for Intel Server Chassis/System

4x3.5 Hot-Swap Drive Cage Kit Installation Guide for Intel Server Chassis/System 4x3.5" Hot-Swap Drive Cage Kit Installation Guide for Intel Server Chassis/System Order Number: G23758-002 G23758-002 This document provides instructions for installing the following accessory kit: FUP4X35HSDK

More information

aseries A13B Mini Bullet Camera User Manual

aseries A13B Mini Bullet Camera User Manual aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView

More information

SoftRAID 5 QUICK START GUIDE. for OWC ThunderBay

SoftRAID 5 QUICK START GUIDE. for OWC ThunderBay SoftRAID 5 QUICK START GUIDE for OWC ThunderBay TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.2 FEATURES 1.3 ABOUT THIS MANUAL SYSTEM SETUP...2 2.1 GETTING STARTED 2.2 INITIALIZING,

More information

FUJITSU Server PRIMERGY RX100 S8

FUJITSU Server PRIMERGY RX100 S8 Operating Manual - English FUJITSU Server PRIMERGY RX100 S8 Operating Manual Edition November 2013 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of

More information

Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001

Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001 Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,

More information

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards 1.2 PACKAGE

More information

PRIMERGY Econel 50 Server System

PRIMERGY Econel 50 Server System PRIMERGY PRIMERGY Econel 50 Server System Service Supplement Xenia Fierley Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: [email protected] Tel.: (089) 61001-157 Fax: 0 700

More information

System Board D2863 for PRIMERGY RX100 S6

System Board D2863 for PRIMERGY RX100 S6 Technical Manual - English System Board D2863 for PRIMERGY RX100 S6 Technical Manual Edition February 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

2 Port PCI Express SATA 6Gbps Controller - 1x esata + 1x SATA

2 Port PCI Express SATA 6Gbps Controller - 1x esata + 1x SATA 2 Port PCI Express SATA 6Gbps Controller - 1x esata + 1x SATA PEXSAT31E1 *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES:

More information

StorTrends 3400 Hardware Guide for Onsite Support

StorTrends 3400 Hardware Guide for Onsite Support StorTrends 3400 Hardware Guide for Onsite Support MAN-3400-SS 11/21/2012 Copyright 1985-2012 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200

More information

QNAP RAID Expansion Enclosure Hardware User Manual. 2014. QNAP Systems, Inc. All Rights Reserved.

QNAP RAID Expansion Enclosure Hardware User Manual. 2014. QNAP Systems, Inc. All Rights Reserved. QNAP RAID Expansion Enclosure Hardware User Manual 2014. QNAP Systems, Inc. All Rights Reserved. Thank you for choosing QNAP products! This user manual provides descriptions of the hardware of the QNAP

More information

HP UPS R1500 Generation 3

HP UPS R1500 Generation 3 HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications

More information

Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server

Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server Advanced Blade Ecosystem the ideal platform for branch offices and mediumsized companies Fujitsu PRIMERGY BX Blade Servers meet all the requirements of

More information

Cisco TelePresence MCU 4500 Series safety and compliance information

Cisco TelePresence MCU 4500 Series safety and compliance information Cisco TelePresence MCU 4500 Series safety and compliance information On this page: Safety information symbols Operating guidelines Safety warnings Technical specifications Compliance information WEEE information

More information

PRIMERGY RX300 S6 Server

PRIMERGY RX300 S6 Server Service Supplement - english PRIMERGY RX300 S6 Server Service Supplement Edition March 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

Fujitsu PRIMERGY BX600 S3 Blade Server

Fujitsu PRIMERGY BX600 S3 Blade Server Datasheet Fujitsu PRIMERGY BX600 S3 Blade Server Advanced Blade Ecosystem - the ideal platform for branch offices and medium-sized companies The PRIMERGY BX Blade Servers are the ideal choice for the data

More information

SSDNow For Desktops. Installation Guide

SSDNow For Desktops. Installation Guide Installation Guide Your purchase of the SSDNow with Accessory Kit will allow you to enjoy the benefits of increased system performance and reliability. All hardware and software necessary to replace your

More information

M.2 NGFF SSD to 2.5in SATA Adapter

M.2 NGFF SSD to 2.5in SATA Adapter M.2 NGFF SSD to 2.5in SATA Adapter SAT2M2NGFF25 *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario - es.startech.com

More information

USB to IDE or SATA Adapter

USB to IDE or SATA Adapter USB to IDE or SATA Adapter USB 2.0 to IDE or SATA Adapter Cable USB2SATAIDE Instruction Manual Actual product may vary from photo FCC Compliance Statement This equipment has been tested and found to comply

More information

SATA PCI Express Adapter PEXSATA22I

SATA PCI Express Adapter PEXSATA22I SATA PCI Express Adapter PEXSATA22I FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS Before you install or use the apparatus, you must read and understand these Important Safety Instructions. At all times when using the apparatus you must follow these Important

More information

Beckhoff onboard SATA-RAID

Beckhoff onboard SATA-RAID Installation and operating instructions for Beckhoff onboard SATA-RAID Version: 1.3 Date: 2009-07-24 Table of contents Table of contents 1. 2. 3. 4. 5. 6. 7. General notes 2 Notes on the documentation

More information

PRIMERGY RX200 S6 Server

PRIMERGY RX200 S6 Server Options Guide - English PRIMERGY RX200 S6 Server Options Guide Edition November 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

USB 3.0/eSATA Dual 2.5/3.5 SATA HDD Dock with UASP

USB 3.0/eSATA Dual 2.5/3.5 SATA HDD Dock with UASP USB 3.0/eSATA Dual 2.5/3.5 SATA HDD Dock with UASP SDOCK2U33EB *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario

More information

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN BeoLab 7-6 Guide CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified

More information

NFC Communication Tray Model: HHX-IT3-Z

NFC Communication Tray Model: HHX-IT3-Z INSTRUCTION MANUAL NFC Communication Tray Model: HHX-IT3-Z ENGLISH CONTENTS Introduction...3 Important safety information...4 Know your unit...6 Transferring data to the PC...7 Care and maintenance...8

More information

2-Port SATA 6Gbps PCI Express Controller 2-Port esata 6Gbps PCI Express Controller

2-Port SATA 6Gbps PCI Express Controller 2-Port esata 6Gbps PCI Express Controller 2-Port SATA 6Gbps PCI Express Controller 2-Port esata 6Gbps PCI Express Controller PEXSAT32 PEXESAT32 DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del

More information

EVGA Z97 Classified Specs and Initial Installation (Part 1)

EVGA Z97 Classified Specs and Initial Installation (Part 1) User Guide EVGA Z97 Classified Specs and Initial Installation (Part 1) - 1 - Table of Contents Before you Begin 3 Parts Not in the kit.4 Intentions of the kit 4 Motherboard Specifications 5 Unpacking and

More information

Data Sheet Fujitsu PRIMERGY BX900 S1 Blade Server

Data Sheet Fujitsu PRIMERGY BX900 S1 Blade Server Data Sheet Fujitsu PRIMERGY BX900 S1 Blade Server The Dynamic Cube Fujitsu PRIMERGY BX Blade Servers meet all the requirements of medium-sized companies as well as the branches and data centers of large

More information

Wave/PC Interactive System USB Adapter Kit. Installation Guide

Wave/PC Interactive System USB Adapter Kit. Installation Guide Wave/PC Interactive System USB Adapter Kit Installation Guide Safety Information 1. Read these instructions for all components before using this product. 2. Keep these instructions for future reference.

More information

BIG GAMES HOME VIDEO ARCADE ASSEMBLY INSTRUCTIONS

BIG GAMES HOME VIDEO ARCADE ASSEMBLY INSTRUCTIONS TM BIG GAMES HOME VIDEO ARCADE ASSEMBLY INSTRUCTIONS IN-HOME ASSEMBLY OF YOUR BIGGAMES HOME VIDEO ARCADE MAY BE AVAILABLE IN YOUR AREA FOR AN ADDITIONAL CHARGE. FOR INFORMATION, PLEASE CALL (800) 749-4345.

More information

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10 Business Audio System: Music & Messaging MP3 Player by Grace Digital Audio User Guide Model No. GDI-USBM10 User Guide Contents Introduction 2 Safety & General Use Information 2 Features 3 Set Up & Operation

More information

USB 3.0/eSATA Dual 3.5 SATA HDD Enclosure

USB 3.0/eSATA Dual 3.5 SATA HDD Enclosure USB 3.0/eSATA Dual 3.5 SATA HDD Enclosure S3520BU33ER / S3520WU33ER *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía

More information

PCI Express USB 2.0 Adapter Card

PCI Express USB 2.0 Adapter Card PEXUSB400 Instruction Manual PCI Express USB 2.0 Adapter Card 4-Port (Independent) PCI Express to High Speed USB 2.0 Adapter Card FCC Compliance Statement This equipment has been tested and found to comply

More information

4 Drive esata USB FireWire External SATA RAID Enclosure

4 Drive esata USB FireWire External SATA RAID Enclosure 4 Drive esata USB FireWire External SATA RAID Enclosure S354UFER *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del

More information

3.5 USB 3.0 to SATA III HDD Enclosure with UASP Support

3.5 USB 3.0 to SATA III HDD Enclosure with UASP Support 3.5 USB 3.0 to SATA III HDD Enclosure with UASP Support S3510BMU33 S3510SMU33 *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com

More information

NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.

NOTE: Additional user information for your printer may be available in the Manuals section at support.dell.com. CAUTION: General Safety Instructions Use the following safety guidelines to help ensure your own personal safety and to help protect your equipment and working environment from potential damage. NOTE:

More information

Serial ATA Hard Drive Enclosure

Serial ATA Hard Drive Enclosure SAT2510U2E SAT2510BU2E Instruction Manual Serial ATA Hard Drive Enclosure 2.5 esata/usb External Hard Drive Enclosure for Serial ATA Hard Drives FCC Compliance Statement This equipment has been tested

More information

Bluetooth Stereo Headphone. User Guide. Hive

Bluetooth Stereo Headphone. User Guide. Hive Bluetooth Stereo Headphone User Guide Hive 1. Product Description Avantree Hive is a Bluetooth stereo headphone with MIC from the Avantree family. It delivers clear voice transmission and high quality

More information

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN-00076-A

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN-00076-A 2-3 SAS/SATA II HDD Canister XC-23D1-SA10-0-R USER S MANUAL Document number: MAN-00076-A ii Preface Important Information Warranty Our product is warranted against defects in materials and workmanship

More information

USB 3.0 to 2.5 SATA HDD Enclosure with ISO

USB 3.0 to 2.5 SATA HDD Enclosure with ISO USB 3.0 to 2.5 SATA HDD Enclosure with ISO S2510BU3ISO *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario -

More information

User Guide Nokia Portable Wireless Charging Plate DC-50

User Guide Nokia Portable Wireless Charging Plate DC-50 User Guide Nokia Portable Wireless Charging Plate DC-50 Issue 1.1 EN User Guide Nokia Portable Wireless Charging Plate DC-50 Contents For your safety 3 About your accessory 4 Keys and parts 5 Top up your

More information

BladeRunner 4U Blade Server User Manual. December 2004 (Revision A)

BladeRunner 4U Blade Server User Manual. December 2004 (Revision A) BladeRunner 4U Blade Server User Manual December 2004 (Revision A) Copyright Notice The copyright in all material provided in this User Manual is held by Penguin Computing Inc. or by the original creator

More information

4 Port PCIe 2.0 SATA III 6Gbps RAID Controller

4 Port PCIe 2.0 SATA III 6Gbps RAID Controller 4 Port PCIe 2.0 SATA III 6Gbps RAID Controller PEXSAT34SFF *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed

More information

Kinivo 301BN HDMI Switch

Kinivo 301BN HDMI Switch Kinivo 301BN HDMI Switch User Manual 2012 Kinivo LLC. All rights reserved. Kinivo is a trademark of Kinivo LLC. Bluetooth word mark and the Bluetooth logo are registered trademarks of Bluetooth SIG. All

More information

Installation ServerView ESXi CIM Provider V6.12

Installation ServerView ESXi CIM Provider V6.12 Installation Guide - English FUJITSU Software ServerView Suite Installation ServerView ESXi CIM Provider V6.12 VMware vsphere Hypervisor server (ESXi) as of version 4.0 Edition February 2013 Comments Suggestions

More information

PCI Express USB 3.0 Controller Adapter Card

PCI Express USB 3.0 Controller Adapter Card PEXUSB3S2 Instruction Manual PCI Express USB 3.0 Controller Adapter Card 2-Port PCI Express SuperSpeed USB 3.0 Controller Adapter Card FCC Compliance Statement This equipment has been tested and found

More information

IDE ATA/133 Controller

IDE ATA/133 Controller IDE ATA/133 Controller 2 Port PCI ATA-133 IDE Adapter Card PCIIDE2 Actual product may vary from photo FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class

More information

Compaq Presario Desktop Products. Upgrading and Servicing Guide

Compaq Presario Desktop Products. Upgrading and Servicing Guide Compaq Presario Desktop Products Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to

More information

PRIMERGY TX140 S1 Server

PRIMERGY TX140 S1 Server Operating Manual - English PRIMERGY TX140 S1 Server Operating Manual Edition May 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

SATA and SAS Hard Drive Backplane

SATA and SAS Hard Drive Backplane SATSASBAY3BK Instruction Manual SATA and SAS Hard Drive Backplane 3 Drive 3.5 Removable SATA/SAS Mobile Rack Backplane FCC Compliance Statement This equipment has been tested and found to comply with the

More information

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN BeoLab 4000 Guide CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified

More information

PCI Express esata/sata 6Gbps Controller

PCI Express esata/sata 6Gbps Controller PCI Express esata/sata 6Gbps Controller PEXESAT322I *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario - es.startech.com

More information

BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES

BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES NOTES BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability Quick Start Guide This is a Class A device and is not intended for use in a residential environment. Important

More information

Small form factor bay converter and hard drive installation

Small form factor bay converter and hard drive installation Small form factor bay converter and hard drive installation HP xw6600 and HP xw8600 Workstations This document describes how to convert HP xw6600 and HP xw8600 Workstation 3.5-inch hard drive bays to hold

More information

USB 3.0 SATA/IDE 2.5 Hard Drive Enclosure

USB 3.0 SATA/IDE 2.5 Hard Drive Enclosure USB 3.0 SATA/IDE 2.5 Hard Drive Enclosure UNI251BMU33 *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario -

More information

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use. BeoLab 11 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equip ment to dripping or splashing and ensure that no objects

More information

1 Port PCI Express IDE Controller Adapter Card

1 Port PCI Express IDE Controller Adapter Card 1 Port PCI Express IDE Controller Adapter Card PEX2IDE *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario -

More information

USB 3.0 to M.2 NGFF SSD Enclosure with UASP

USB 3.0 to M.2 NGFF SSD Enclosure with UASP USB 3.0 to M.2 NGFF SSD Enclosure with UASP SM2NGFFMBU33 *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario

More information

HP 22-in-1 Media Card Reader

HP 22-in-1 Media Card Reader HP 22-in-1 Media Card Reader Introduction This document describes how to install the HP 22-in-1 Media Card Reader into an HP Workstations adapter bracket, and then install the media card reader and bracket

More information

USB 3.0 to SATA or IDE Hard Drive Adapter Converter

USB 3.0 to SATA or IDE Hard Drive Adapter Converter USB 3.0 to SATA or IDE Hard Drive Adapter Converter USB3SSATAIDE *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del

More information

2.5/3.5 SATA HDD Docking Station

2.5/3.5 SATA HDD Docking Station SATADOCKU2 SATADOCKU2E SATADOCK22UE 2.5/3.5 SATA HDD Docking Station FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to

More information

Digital Satellite Receiver

Digital Satellite Receiver USER GUIDE Digital Satellite Receiver Models DSR207, DSR317, DSR505, and DSR530 CONTENTS IMPORTANT SAFETY INSTRUCTIONS...1 DSR BASICS SYMBOLS/ICONS...6 Front Panel...6 Back Panel...7 CONNECTING YOUR DSR...10

More information

PROGRAMMER INSTALLATION INSTRUCTIONS

PROGRAMMER INSTALLATION INSTRUCTIONS PROGRAMMER INSTALLATION INSTRUCTIONS TABLE OF CONTENTS Description 4 Installation 4 Operation 5 Safety Precautions 6 Regulatory & Service Information 6 Important Safety and Usage Information 7 Regulatory

More information

3-4 SAS/SATA II HDD Canister Deluxe version

3-4 SAS/SATA II HDD Canister Deluxe version 3-4 SAS/SATA II HDD Canister Deluxe version XC-34D1-SA1C-0-R USER S MANUAL Document number: MAN-00078-B P/N: H88CM34001-00001-0 Important Information Warranty Our product is warranted against defects in

More information

USER GUIDE. Access to the Server is via the following webpage: www.admin.airgoosignage.co.uk

USER GUIDE. Access to the Server is via the following webpage: www.admin.airgoosignage.co.uk USER GUIDE The A+K Airgoo Digital Signage MicroPlayer is a totally new generation of product with wireless capabilities and innovative features. It is designed to operate with our Digital Signage Server

More information

3.5 External Hard Drive Enclosure

3.5 External Hard Drive Enclosure UNI3510U2E / UNI3510U2EGB UNI3510U2EB / UNI3510UEBGB Instruction Manual 3.5 External Hard Drive Enclosure 3.5 esata/usb 2.0 to IDE/SATA External Hard Drive Enclosure with One-Touch Backup FCC Compliance

More information

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers! BeoLab 6002 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equip ment to dripping or splashing and ensure that no objects

More information

Wireless Optical Travel Mouse

Wireless Optical Travel Mouse Wireless Optical Travel Mouse User s Manual PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING THIS DEVICE. Table of Contents FCC Statement Page 3 Introduction.. Page 6 Package Contents.. Page

More information

User Guide for the Wireless Headset (HS-11W) 9235346 Issue 1

User Guide for the Wireless Headset (HS-11W) 9235346 Issue 1 User Guide for the Wireless Headset (HS-11W) 9235346 Issue 1 DECLARATION OF CONFORMITY We, NOKIA CORPORATION declare under our sole responsibility that the product HS-11W is in conformity with the provisions

More information

AXIS 291 1U Video Server Rack Installation Guide

AXIS 291 1U Video Server Rack Installation Guide AXIS 291 1U Video Server Rack Installation Guide About This Document This document describes how to install Axis blade video servers in the AXIS 291 1U Video Server Rack. Updated versions of this document

More information

4 Port PCI Express Low Profile High Speed USB Card

4 Port PCI Express Low Profile High Speed USB Card 4 Port PCI Express Low Profile High Speed USB Card PEXUSB4DP DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario - es.startech.com IT: Guida per

More information

esata External Storage

esata External Storage esata External Storage Operation Manual DA-ES110 Before reading this manual This operation manual contains basic instruction on installing and using esata External Storage, an IDIS product. Users who are

More information

PRIMERGY TX150 S7 Server

PRIMERGY TX150 S7 Server Options Guide - English PRIMERGY TX150 S7 Server Options Guide Edition October 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

PRIMERGY TX200 S4. Operating manual

PRIMERGY TX200 S4. Operating manual PRIMERGY TX200 S4 Operating manual Edition March 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information