ALWAYS THE SAFE CHOICE! Electronic door locking systems.
|
|
|
- Abner Johnson
- 9 years ago
- Views:
Transcription
1 ALWAYS THE SAFE CHOICE! Electronic door locking systems 33
2 Program and performance overview of the series TSE 4000 and TSE 5000 The TSE product range: Everything at a glance! TSE Set 4001 HOME TSE Set 5011 PINCODE TSE Set 5012 FINGERSCAN TSE Set 5013 E-KEY Possible code combinations 1 million 1 million 1 million How many digits is the PINCODE? 6 digits 6 digits 6 digits Number of possible users Number of possible PINCODES Number of possible FINGERSCANS 24 1) Number of possible E-KEYS ) Safe AES encryption Menu-controlled user guidance 4 4 Multilingual menu guidance 4 4 Assembly position control unit Assembly control unit Outdoor area protected IP 65 Outdoor area protected from weather from weather (IP 54) Backset Inward opening door 25 mm 3) Outward opening door 35 mm 3) Keypad fixing position Up to 10 m from door surrounding Master key function with user administration Via TSE SOFTWARE (optional) 4) Programming via keypad Software Timer functions 4 via TSE SOFTWARE History trace 4 via TSE SOFTWARE Stored historical events Last 600 events Power supply Keypad 2 x LR06 4 x LR06 4 x LR06 Cylinder 2 x LR03 2 x LR06 2 x LR06 2 x LR06 E-Key 1 x CR 2032 Possible operations with one set of batteries 5) Keypad Cylinder Standby-time Keypad 2,5 years 3,5 years 3,5 years Cylinder 2,5 years 2,5 years 2,5 years 2,5 years Battery exchange advice Memory protection without batteries Mechanical emergency lock ) Every finger occupies one user memory, for an additional CODE or E-KEY a second user memory will be occupied. 2) Registration via TSE SOFTWARE. 3) Applies to door thickness, where the profile cylinder is not overlapping. For other doors please contact us. 4) Fingerscan data can only be programmed via the keypad FS unit. No transmission via software possible. 5) With an optimally adjusted radio channel. Mistakes, changes and further technical developments reserved. Profile cylinders for emergency doors, free-wheeling on both sides and/or half-cylinder see page 42. The keypad of the TSE 5000 BUSINESS series: protection against weather, water, dirt Weatherproof: The TSE Keypad PINCODE protection class IP 65 according to EN Absolute protection against water and dust is guaranteed. The TSE Keypad FINGERSCAN fulfills protection class IP 54 criteria and is suitable for installation in areas protected from weather. Comfortable: Touch panel technology - comfortable handling: The user activates the system by touching one of the buttons. It can be operated safely thanks to the cool blue lighting. Weatherproof: TSE Set 5011 WP PINCODE, TSE Set 5012 WP FS and TSE Set 5013 WP E-KEY with additionally weatherproof sealed cylinder. Version WP 34
3 TSE 4000 HOME Electronic door lock TSE HOME SET 4001 The affordable entry-level solution for one door Complete set for interior and exterior doors: Electronic TSE-profile-cylinder communicates wireless with keypad, incl. batteries, operating and assembly instructions. SECURE 1 million different codes possible up to 6 users can be programmed: One 6-digit code and up to 5 optional radio keys TSE E-KEY optimum protection against manipulation without mechanical emergency lock COMPATIBLE for all doors with a thickness of up to 120 mm (60/60) for interior and exterior doors WIRELESS keypad can be fixed in a 10 m range from the door SIMPLE assembly without cabling, drilling, etc. the electronic TSE-profile-cylinder replaces the mechanical one existing fittings remain unchanged no drilling - easy to replace (s. p. 38) keypad assembly only in weather-protected areas TSE Set 4001 HOME MCR Art.-No. EAN Colours TSE Set 4001 HOME W white TSE Set 4001 HOME MCR matt chrome TSE Stainless steel cover Stainless steel cover protects against humidity, vandalism and code spying. Can be refitted without any difficulties. TSE Stainless steel cover EBL SB suitable for keypads 4001 Home TSE stainless steel cover (shown with Keypad 4001) Radio key TSE E-KEY Electronic radio key - handy and attractive. distance between radio key and door lock can be up to 3 m depending on environmental conditions manual mode: TSE Wireless opens at the push of a button E-KEY has to be used automatic mode (only 5011/5012): TSE Wireless opens after activating the KEYPAD TSE E-KEY does not have to be used battery change display, power supply: standard CR 2032 coin cell optimal use via PC software use the E-KEY as a master key to open different cylinders or safes TSE 5103 E-KEY SB optional E-KEYS can be used up to the above-mentioned number TSE E-KEY 35
4 TSE 5000 BUSINESS Electronic door lock TSE BUSINESS SET 5011 PINCODE Complete set for interior and exterior doors: Electronic TSE profile cylinder communicates wireless with the KEYPAD PINCODE, incl. batteries, operating and assembly instructions TSE Set 5011 PINCODE Protection class IP 65 SECURE up to 48 users can be programmed (incl. 1 admin code) 1 million different codes possible 6-digit user codes (optional: radio keys TSE E-KEY) optimum protection against manipulation incl. mechanical emergency lock (2 keys) keypad weatherproof, protection class IP 65 COMPATIBLE for all doors with a thickness of up to 120 mm (60/60) for interior and exterior doors WIRELESS keypad can be fixed in a 10 m range from the door illuminated keypad keypad operation via touch panel SIMPLE no cabling, no drilling, etc. the electronic TSE profile cylinder replaces the mechanical one existing fittings remain unchanged no drilling - easy to replace (s. p. 38) inside cylinder needs to be placed in weather-protected areas PC COMPATIBLE our optional TSE software offers several additional functions such as: - user administration exclusively for pincodes or E-Keys - administration of access time and access rights for pincodes or E-Keys - history readout, etc. Version WP Set with weatherproof sealed cylinder Version WP TSE Set 5011 PINCODE standard cylinder TSE Set 5011 WP PINCODE weatherproof cylinder Electronic door lock TSE BUSINESS SET 5012 FINGERSCAN Complete set for interior and exterior doors: Electronic TSE profile cylinder communicates wireless with the KEYPAD FINGERSCAN, incl. batteries, operating and assembly instructions TSE Set 5012 FINGERSCAN Protection class IP 54 SECURE up to 48 users can be programmed (incl. 1 admin code) therefrom up to 24 fingerscans additional users with a 6-digit PINCODE or optional TSE E-Key can be programmed 1 million different codes possible optimum protection against manipulation incl. mechanical emergency lock (2 keys) keypad assembly only in weather-protected areas, IP 54. COMPATIBLE for all doors with a thickness of up to 120 mm (60/60) for interior and exterior doors WIRELESS keypad can be fixed in a 10 m range from the door illuminated keypad keypad operation via touch panel SIMPLE no cabling, no drilling, etc. the electronic TSE profile cylinder replaces the mechanical one existing fittings remain unchanged no drilling - easy to replace (s. p. 38) inside cylinder needs to be placed in weather-protected areas PC COMPATIBLE our optional TSE software offers several additional functions such as: - user management of pincodes or E-Keys - administration of access time and access rights for pincodes or E-Keys - history readout, etc. Version WP Set with weatherproof sealed cylinder Version WP TSE Set 5012 FINGERSCAN standard cylinder TSE Set 5012 WP FS weatherproof cylinder 36
5 TSE 5000 BUSINESS Electronic door lock TSE BUSINESS SET 5013 E-KEY Complete set for interior and exterior doors: Electronic TSE profile cylinder communicates wireless with the radio key TSE E-KEY, incl. batteries, operating and assembly instructions SECURE up to 47 TSE E-KEYS programmable (via TSE SOFTWARE) optional TSE PINCODE / FINGERSCAN keypad optimum protection against manipulation incl. mechanical emergency lock (2 keys) COMPATIBLE for all doors with a thickness of up to 120 mm (60/60) for interior and exterior doors WIRELESS operation without keypad via TSE E-KEY SIMPLE no cabling, no drilling, etc. electronic TSE profile cylinder replaces the mechanical one existing fittings remain unchanged no drilling - easy to replace (s. p. 38) inside cylinder needs to be placed in weatherprotected areas PC COMPATIBLE via the optional PC software including functions such as user management, granting of time slots and rights, history readout, etc. possible Version WP Set with weatherproof sealed cylinder TSE Set 5013 E-KEY Version WP TSE Set 5013 E-KEY standard cylinder TSE Set 5013 WP E-KEY weatherproof cylinder Radio key TSE E-KEY Electronic radio key - handy and attractive. distance between radio key and door lock can be up to 3 m depending on environmental conditions manual mode: TSE Wireless opens at the push of a button E-KEY has to be used automatic mode (only 5011/5012): TSE Wireless opens after activating the KEYPAD TSE E-KEY does not have to be used battery change display, power supply: standard CR 2032 coin cell optimal use via PC software TSE 5103 E-KEY SB optional E-KEYS can be used up to the abovementioned number TSE E-KEY TSE software for more functionality Professional administration and configuration of your entire door locking system naming of users programming of - pincodes - radio keys (TSE E-KEY) administration of access times and access rights and calendar function history readout while programming, the distance between PC and TSE profile cylinder can be up to 25 m system requirements Windows XP, Vista or Windows 7 or Windows 8 (Windows tablets as of version 8.1) in a standard configuration, USB-Port no permanent radio controlled connection between PC and TSE necessary TSE Software Art.-No. EAN Users Doors up to up to TSE 5500 Software LIGHT SB TSE 6501 SOFTWARE SYSTEM* * Further information on the TSE 6501 SOFTWARE SYSTEM see page
6 Assembly instructions -TSE electronic cylinder Simple to install a few steps to attain electronic security for interior and exterior doors: The wireless-technology permits easy fitting without drilling, sawing, wiring, etc. series TSE 4000 HOME 1 Remove the existing profile cylinder and replace it with the electronic TSE-profile-cylinder, which must be inserted from the outside. series TSE 5000 BUSINESS Remove the existing profile cylinder 1 and replace it with the electronic TSE-profile-cylinder, which must be inserted from the inside. 2 Fix the electronic TSE-profile-cylinder on the door as usual. 2 Fix the electronic TSE-profile-cylinder on the door as usual. 3 Adjust to the door thickness by integrated detent system. 3 Adjust to the door thickness by integrated detent system. 4 Fix the knob by using the enclosed hex key. 4 Fix the exterior knob by using the enclosed hex key. 5 TSE HOME Set 4001: Install the TSE Keypad at an appropriate place. The distance between TSE Keypad and your door can be up to 10 m. Up to 5 optional radio keys TSE E-KEY can be used. 5 TSE BUSINESS Set 5011 PINCODE, Set 5012 FINGERSCAN: Install the TSE Keypad PINCODE or FINGERSCAN* at an appropriate place. The distance between TSE Keypad PINCODE/ FINGERSCAN and your door can be up to 10 m. * in weather-protected areas. TSE BUSINESS Set 5013 E-KEY: Tip: We prepare you for future business! For training on installation and application of TSE HOME and BUSINESS, just contact us at [email protected]. Open or close the door simply and safely by pushing the button of your TSE E-KEY or by entering a 6-digit user code into the keypad of the TSE Keypad PINCODE or FINGERSCAN which are optionally available. 38
7 Dimensions TSE cylinder 5000 Outer side Dimensions in mm Inner side 1-30 mm 1-30 mm Ø 30 Ø Mechanical emergency lock Detent system: the cylinder is adjustable to any door thickness of up to 120 mm (60/60) Batteries (2 x LR06) Function control LED Profile cylinders for emergency doors, free-wheeling on both sides and/or half-cylinder (s.p.42). Mistakes, changes and further technical developments reserved. TSE presentation tools TSE Pocket Brochure Box including 50 TSE HOME & BUSINESS brochures (Art.-No ) TSE Display for the functional presentation of the products of the range TSE 5000 BUSINESS, H 65 x W 40 x D 20 cm, base: H 72 x W 42 x D 33 cm TSE SYSTEM DISPLAY for functional presentation of the individual components of the TSE 6000 SYSTEM series, H 54 x W 40 x D 25 cm Counter TSE 4000 HOME counter (Art.-No ), dimensions 48 x 38 cm, incl. adapted boards (81942) on demand incl. base (Art.-No ) for free installation, base: 76 x 42 x 33 cm Individual components of the TSE 6000 SYSTEM series starting on page 40 39
8 IDENTIFICATION MEDIUM ADD-ON MODULES TSE 6120 FACE TSE 6201 Control TSE 6202 Switch TSE 6203 Enrollment TSE 6000 CyLINDER VERSIONS: TSE 6010 TWIN TSE 6111 Keypad PIN PINCODE TSE 6020 ANTIPANIC TSE 6030 HALF TSE 6112 Keypad FS Fingerscan TSE SYSTEM overview TSE 6103 E-KEY TSE 6107 CHip TSE 6104 CARD TSE 6115 KEYPAD CARD Developed for a world without keys. TSE 6106 CARD-READER * PINCODE and FINGERSCAN versions available in white and stainless steel. TSE POWER Keypad* SOFTWARE TSE 6501 Software SYSTEM TSE 6502 Software SYSTEM + TSE 6450 Software HOTEL Mistakes, changes and further technical developments reserved.
9 TSE 6000 SYSTEM OVERVIEW Components for the functional expansion of TSE 5000 BUSINESS and for the configuration of individual electronic locking systems. Technical data sheets of the individual components are available for download in the product section of our website! Primarily for commercial buildings. TSE System is especially economical, easy to install, expandable and timelessly beautiful. TSE CYLINDER TSE 6000 CYLINDER TSE 6001 CYLINDER TSE 6010 TWIN TSE 6020 ANTIPANIC TSE 6030 HALF TSE 6090 SHAFT EXTENSION page 42 TSE IDENT MEDIA TSE 6111 Keypad PIN TSE 6112 Keypad FS TSE 6103 E-KEY TSE 6115 Keypad CARD TSE 6106 CARD READER TSE 6206 Cover CARD TSE 6107 CHIP TSE 6104 CARD TSE 6111 POWER Keypad PIN TSE 6112 POWER Keypad FS TSE 6120 FACE page 44 Advanced solutions for businesses, hotels, clinics,... Safety comfort on the highest level. TSE SYSTEM is designed for all types of applications, such as office buildings, manufacturing facilities, research facilities, universities, hospitals, nursing homes and more. A special variant of the system has been developed for hotels. TSE ADD-ON MODULES TSE 6201 CONTROL TSE 6202 SWITCH TSE 6203 ENROLLMENT UNIT page 47 TSE SOFTWARE TSE SYSTEM 6501 TSE SYSTEM TSE HOTEL 6450 page 48 More detailed technical information is available in our TSE SYSTEM catalogue. Order now! 41
10 TSE 6000 SYSTEM CYLINDER TSE 6000/6001 CYLINDER Electronic Cylinder - standard version TSE 6000 CYLINDER external closure with identification medium dimensions 30/30 door thicknesses up to 120 mm (60/60) adjustable through detent system online capability cabling free assembly, internal electronics up to 2000 users with time and calender function as well as assignments of rights via TSE management software usable identification media radio key E-key, Pincode, Fingerscan ( possible fingerprints), transponder card or CHIP batteries: Mignon LR 6 battery life span up to 62,000 closures (depends on identification medium) mechanical emergency opening convertible for hotel use Version TSE 6001 CYLINDER: technical description as above, but without mechanical emergency opening TSE 6000 CYLINDER standard version TSE 6001 CYLINDER without mechanical emergency opening TSE 6001 CYLINDER TSE 6010 TWINLOCK Electronic Cylinder - double sided closing closure at both sides with identification medium dimensions 30/35 door thicknesses up to 125 mm (60/65) adjustable through detent system online capability cabling free assembly internal electronics up to 2000 users with time and calender function as well as assignments of rights via TSE management software usable identification media: radio key E-key, Pincode, Fingerscan ( possible fingerprints), transponder card or CHIP batteries: Mignon LR 6 battery life span up to 62,000 closures (depends on identification medium) convertible for hotel use TSE 6010 TWINLOCK TSE 6010 TWIN double sided closing TSE 6020 ANTIPANIC Electronic Cylinder for escape doors with anti-panic locks closure at both sides with identification medium dimensions 30/45 door thicknesses up to 60/75 adjustable through detent system online capability cabling free assembly, internal electronics up to 2000 users with time and calender function as well as assignments of rights via TSE management software usable identification media: radio key E-key, Pincode, Fingerscan ( possible fingerprints), transponder card or CHIP batteries: Mignon LR 6 battery life span up to 62,000 closures (depends on identification medium) mechanical emergency opening convertible for hotel use TSE 6020 ANTIPANIC TSE 6020 ANTIPANIC for escape doors 42
11 TSE 6000 SYSTEM CYLINDER More detailed technical information is available in our TSE SYSTEM catalogue. Order now! TSE 6030 HALF Electronical half cylinder the knob cannot be dismantled for safety reasons closure with identification medium dimensions 35/10 mm online capability cabling free assembly up to 2000 users with time and calender function as well as assignments of rights via TSE management software usable identification media: radio key E-key, Pincode, Fingerscan ( possible fingerprints), transponder card or CHIP batteries: Mignon LR 6 battery life span up to 62,000 closures (depends on identification medium) TSE 6030 HALF electronical half cylinder TSE 6030 HALF TSE 6090 SHAFT EXTENSION The shaft extension is designed to extend the outer shaft for larger door thicknesses which are required for fire protection. It is mounted onto the existing shaft and flexibly adapted to the door size. The maximal distance is 104 mm (measured from the fixing screw). TSE 6090 WVE shaft extension TSE 6090 WVE TSE 6000 surcharge weatherproof version Weatherproof TSE 6000 surcharge pour version intempéries weatherproof version Technical data sheets of the individual components are available for download in the product section of our website: 43
12 TSE 6000 SYSTEM IDENTIFICATION MEDIA TSE 6111 Keypad PIN Protection class IP 65 according to DIN EN 60529, wireless pincode keypad as identification medium compatible with all cylinders from the 6000 series as well as TSE 6201 Control range up to 10 m from the cylinder touch panel incl. cool blue lighting own power supply batteries: 4 x Mignon LR 6 TSE 6111 Keypad PIN Keypad Pincode TSE 6111 Keypad PIN TSE 6112 Keypad FS Protection class IP 54 according to EN 60529, wireless fingerscan unit with integrated pincode keypad as identification medium advanced sensor technology, fast evaluation of the finger, fake finger detection compatible with all cylinders from the 6000 series as well as TSE 6201 Control range up to 10 m from the cylinder touch panel incl. cool blue lighting own power supply batteries: 4 x Mignon LR 6 TSE 6112 Keypad FS TSE 6112 Keypad FS Keypad Fingerscan TSE POWER Keypad 6111 Protection class IP 53 according to EN 60529, wired pincode keypad as identification medium compatible with all cylinders from the 6000 series as well as TSE 6201 Control range up to 10 m from the cylinder touch panel incl. cool blue lighting voltage range of V DC frame available in galvanized steel painted white or brushed stainless steel TSE POWER Keypad 6111 W TSE POWER Keypad 6111 Ni Keypad Pincode with mains connection TSE POWER Keypad 6111 W Keypad Pincode with mains connection TSE POWER Keypad 6112 FS Protection class IP 53 according to EN 60529, wired Fingerscan Keypad with integrated Pincode Keypad as identification medium advanced sensor technology, fast evaluation of the finger, fake finger detection compatible with all cylinders from the 6000 series as well as TSE 6201 Control range up to 10 m from the cylinder touch panel incl. cool blue lighting voltage range of V DC frame available in galvanized steel painted white or brushed stainless steel TSE POWER Keypad 6112 Ni FS TSE POWER Keypad 6112 Ni FS Keypad Fingerscan with mains connection TSE POWER Keypad 6112 W FS Keypad Fingerscan with mains connection 44
13 Smar t Se curity The face replaces the key: The built-in camera of the TSE FACE is switched on automatically when a person approaches the door. If the person is correctly identified, an encrypted signal is transmitted to the electronic lock cylinder and releases the door opening. Wireless communication between face recognition module and lock cylinder. TSE FACE 6120 Biometric face recognition module secure identification of up to 300 authorised persons recognition speed approx. 1 second via the touch panel the door can be opened alternatively by PIN input via onscreen keyboard. easy programming and entering of the authorised persons wireless communication between face recognition module and lock cylinder assembly only indoors TSE FACE face recognition module TSE FACE Wall mounting Table mounting Technical data sheets of the individual components are available for download in the product section of our website: 45
14 TSE 6000 SYSTEM IDENT TSE 6103 E-KEY TSE 6103 E-KEY Active transponder with own power supply with fastening eye distance between the remote control key and cylinder up to 3 m depending on ambient conditions AES-encrypted data transmission applicable for different locking systems batteries: CR 2032 TSE 6103 E-KEY clé électronique TSE 6104 CARD TSE 6104 CARD Transponder card as battery-free passive transponder according to ISO formats and 14443A wireless data transfer AES-encrypted data transmission programmable access rights and validity periods possible ideal for hotel use upon request, also available with company logo TSE 6104 CARD transpondeur CARD TSE 6107 CHIP TSE 6115 Keypad CARD (Shown with optional accessory TSE 6104 CARD) TSE 6107 CHIP Transponder card as battery-free passive transponder according to ISO formats and 14443A wireless data transfer AES-encrypted data transmission ideal for hotel use upon request, also available with company logo TSE 6115 Keypad CARD Protection class IP 65 according to EN wireless keypad as reader for transponder cards according to ISO formats and 14443A. Registration and deleting of transponder cards via keypad possible, additional pincode entry possible. compatible with all cylinders from the 6000 series own power supply touchpanel incl. cool blue lighting batteries: 4x Mignon LR6 AA Alkaline TSE 6107 CHIP transpondeur CHIP TSE 6115 Keypad CARD Keypad as a reader for transponder card TSE 6106 CARD-READER (Shown with optional accessory TSE 6104 CARD) 46 TSE 6106 CARD-READER Flush-mounted wall unit for passive transponders accroding to ISO standards and 14443A standard compliant blind cover (without metal coating) can be used (not included) compatible with all cylinders of the 6000 series as well as with the TSE 6201 Control incl. power supply power supply 230 V TSE 6106 CARD-READER training required More detailed technical information is available in our TSE SYSTEM catalogue. Order now!
15 TSE 6000 SYSTEM ADD-ON TSE 6201 CONTROL The TSE 6201 electronical control unit allows, via the locking system, the control of other electrical devices that belong to a building or premises (garage doors, rolling doors, gates, etc.) operation possible with each TSE identification medium opening and closure contact with time/history function and rights management via TSE management software power supply 5 to 14 V DC and/or nimh or nicd. batteries or LR6 AA batteries 2000 user and fingerscans TSE 6201 CONTROL electrical control unit Technical data sheets of the individual components are available for download in the product section of our website: TSE 6201 CONTROL TSE 6202 SWITCH Switching unit used for integrating external systems and including connectors for alarm systems, time recording systems, Bluetooth modules, and other external devices. power supply: 5-24 V DC TSE 6202 SWITCH switching unit TSE 6202 SWITCH TSE 6203 ENROLLMENT UNIT Programming unit used to store fingerscans with access authorisation as well as passive transponders in the TSE system s management software. TSE 6203 ENROLLMENT UNIT training required TSE 6203 ENROLLMENT UNIT TSE 6206 COVER CARD-READER Blind cover for TSE 6106 CARD-READER available in anthracite fastening via clamping system standard compliance with many switching systems TSE 6206 Cover Card-Reader cover for TSE 6106 Card-Reader TSE 6206 COVER CARD-READER 47
16 TSE 6000 SYSTEM SOFTWARE TSE 6501 SOFTWARE SYSTEM Software designed for up to 250 users and 200 doors. including programming adapter granting access rights time functions (user-based and permanent opening) time functions (control units, TSE Control) history readouts reading fingerscans via the enrollment unit reading/ programming TSE 6104 CARD and TSE 6107 CHIP via enrollment unit programming requirements display import or export of CSV files no permanent radio connection to locks required conversion of old databases possible import of existing databases SQL data base works council function Programming of safes via wireless electronics by BURG-WÄCHTER system requirements: Windows xp / Vista / Windows 7/Windows 8 and Windows tablets as of version 8.1 in standard configuration TSE 6501 SOFTWARE SYSTEM Art.-No. EAN TSE 6501 SOFTWARE SYSTEM TSE 6502 SOFTWARE SYSTEM+ TSE 6502 SOFTWARE SYSTEM+ Multi-client software including programming adapter management of up to 2000 users and 300 doors per client granting access rights time functions (user-based and permanent opening) time functions (control units, TSE Control) history readouts reading fingerscans via the enrollment unit reading/ programming TSE 6104 CARD and TSE 6107 CHIP via enrollment unit programming requirements display multiple print functions via CSV output import or export of CSV files back-up function no permanent radio connection to locks required conversion of old databases possible import of existing databases works council function programming of safes possible system requirements: Windows xp / Vista / Windows 7/Windows 8 and Windows tablets as of version 8.1 in standard configuration Art.-No. EAN TSE 6502 SOFTW. SYSTEM TSE 6450 SOFTWARE HOTEL Conversion of the TSE 6000 cylinders and TSE Control to guest code version establishing check-out time generating individual guest codes for the rooms and communal doors journal function within the software adapting the software to the respective hotel structure compatible with check-in terminals and booking systems system requirements: Windows xp / Vista / Windows 7/Windows 8 and Windows tablets as of version 8.1 in standard configuration TSE 6450 SOFTWARE HOTEL Art.-No. EAN TSE 6450 SOFTWARE HOTEL Training Sessions & Seminars To help you with dealing with complex TSE system components, to provide security and to ensure the best possible service to your customers, a short intensive training is necessary when buying products labeled as such. Please book these easily and simply via [email protected] or our telephone hotline Mistakes, changes and further technical developments reserved. 48
BUSINESS. Elektronisches Türschloss. Installation and User Manual. www.burg-waechter.de. Ingeniously safe. Ingeniously simple.
Elektronisches Türschloss BUSINESS Set 5011 PINCODE Set 5012 FINGERSCAN Set 5013 E-KEY Ingeniously safe. Ingeniously simple. BA/MA TSE Set 5000 dp/fsc 04/2012 Installation and User Manual BURG-WÄCHTER
TSE Administration Software
TSE Administration Software Dear customer, Thank you very much for having chosen a lock administration software by BURG- WÄCHTER. It is available in 4 different versions, which are optimally adapted to
User Manual TSE 6401 Software System
User Manual TSE 6401 Software System Dear Customer, Thank you very much for your decision for the TSE 6401 Software System. The configuration and administration of the complete locking system is based
How To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
Installation Instructions. Thermo Call TC3
Installation Instructions Thermo Call TC3 1 2 # 24990A 965 082 AMP 3 4 # 98393A # 67769A sw Improper installation or repair of Webasto heating and cooling systems can cause fire or the leakage of deadly
SAFE-O-TRONIC access Door and furniture locking systems
Schulte-Schlagbaum AG Next level access since 1833 Product catalogue SAFE-O-TRONIC access Door and furniture locking systems SAFE-O-TRONIC access Product catalogue SAFE-O-TRONIC access Electronic Identification
EASY PROGRAMMING AND TRANSACTION ANALYSIS SOFTWARE
EASY PROGRAMMING AND TRANSACTION ANALYSIS SOFTWARE You can program online 24/7 giving you the freedom to work when and where you want. From remote bookkeeping and access, to security control on the ground
Operating instructions TSE Wireless Software Home
Operating instructions TSE Wireless Software Home Table of contents 1. GENERAL 2 2. INSTALL SOFTWARE 2 2.1. Installation in Windows XP 2 2.2. Installation in Windows Vista 3 3. THE PROGRAM 0 3.1. Setup
Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000
Security Alarm Central Unit 3 4 Technical KNX Alarm central unit EAM 4000 ETS-product family: Alarm system Product type: Alarm central unit The alarm central unit is a modern alarm system using the KNX
BIBUS VOP. large blocks of flats with switchboard and mixed mainly audio systems. Ideal for door phone systems with up to 250 users.
BIBUS VOP Advice for use: large blocks of flats with switchboard and mixed mainly audio systems Ideal for door phone systems with up to 250 users VOP technology Easy creation of mixed audio and video door
Functional Specification Document
Functional Specification Document Access Control Technology Unit C1 South City Business Centre Tallaght Dublin 24 Ireland Ph: + 353 (0) 1 4662570 Web: www.accesscontrol.ie Index Introduction 1.1 Hardware
Product and Application Description
Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
T0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control
Wireless Control Systems Accessories Leading the way in intelligent automation contents Range Overview Typical Installations Transmitters Combined Modules Accessories Programming Switching & Dimmer Functions
A C C E S S C O N T R O L S Y S T E M
A C C E S S C O N T R O L S Y S T E M TIME & ATTENDANCE SYSTEM Model No. Z.AC.R.BIO.M8.TA Z.AC.RC.BIRO.M8+ID.TA Type: BIOMETRIC TIME & ATTENDANCE SYSTEM Combination of silver & black colour Instant verification
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00
Standalone door control module PK-01 Firmware version 1.00 pk-01_en 06/12 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 [email protected] www.satel.eu WARNINGS Read carefully
video door entry system offer
video door entry system offer CATALOGUE 2013 BTICINO Specialists in Video Door Entry Systems BTicino, introduces a complete range of products and systems capable of meeting all application and building
IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre
IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,
Current Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
2013 Wireless Video Intercom INSTALLATION GUIDE
2013 Wireless Video Intercom INSTALLATION GUIDE INDEX System configuration and wiring VL-SWD501 System Component.. 4 VL-SWD501EX wiring schematic diagram VL-SWD501EX wiring type and length... 5.... 6 Door
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Current Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
1838AP 1810AP PG. 48 PG. 42
Telephone Entry PLUS Computer Programming and Control. The DKS Access Plus product line is a true hybrid access control and telephone entry system that is ideal for residential, small apartment, condominium,
Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling
Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE
www.sebury.com.cn Digital Keypad Use s Manual
K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4
SECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
User Manual GSM Alarm System. www.deltasecurity.cn. All rights reserved by Delta Security Co., Ltd
User Manual GSM Alarm System All rights reserved by Delta Security Co., Ltd Dear Clients, Thank you for using our GSM Alarm System. We are committed to giving you the best home security available today
Operating Instructions. Keypad 2605..
Operating Instructions Keypad 605.. Contents Device description...4 Device presentation...5 Areas of application...6 Operation...8 Acknowledgement signals... 10 Start-up sequence... 11 Connection terminals...1
D45. SySTEm. ThE high-performance
D45 ThE high-performance SySTEm Security monitoring system with digital BUS technologies High efficiency system and quick installation for both backbone and riserdevicesthankstotheuse of cat.5e UTP cables
QUANTIFYING SOLAR ENERGY
www.sustainicum.at QUANTIFYING SOLAR ENERGY Recommendations for implementation in the course Author: E-Mail address: Institution: Philipp Weihs [email protected] BOKU Important considerations Very
Repeaters and Mimics Data Sheet
Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.
WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054
WIRELESS ALARM KIT COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS Model Number: IT214054 INSTRUCTION MANUAL Warranty Details/Support This product is warranted against defects for a period of One year if the
KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184
EN KNX TH65-AP Thermo-Hygrometer Technical specifications and installation instructions Item number 70184 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49
Information. Communication for the open minded. Siemens Enterprise Communications www.siemens.com/open
Information Cordless Telephones for HiPath Systems Alongside the system-specific HiPath telephones, Siemens offers additional cordless phones for operation with HiPath systems. These cordless phones will
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
ACCESS CONTROL MANY FUNCTIONS. ONE SYSTEM. ONE CARD.
MANY FUNCTIONS. ONE SYSTEM. ONE CARD. ACCESS CONTROL One card, centrally monitored and controlled provides access to doors, gates, turnstiles and lockers ACCESS CONTROL The Intelligent System from InterCard
Ex15x //DATASHEET. Xs4 Mini. Cutting-edge design + Amazing technology:
//DATASHEET XS4 Mini Cutting-edge design + Amazing technology: Stylish design is a SALTO trademark and with the XS4 Mini, we raise the bar on this already high standard thanks to the XS4 Mini s small,
INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM
INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM Revised: August 28, 2014 PRODUCT REFERENCE MOUNTING ACCESSORIES PIR / MOTION DETECTION UNIT MAIN UNIT POWER ADAPTER MOUNTING ACCESSORIES
DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
Installation Instructions. ThermoCall TC4. Entry/Advanced
Installation Instructions ThermoCall TC4 Entry/Advanced Thermo Call TC4 1 2 # 24990A 965 082 AMP 3 4 # 98393A # 67769A Thermo Call TC4 5 ThermoCall TC4 Entry 1 2 3 4 5 6 7 8 9 10 11 12 sw Please refer
Quick Start Guide. GV-AS Controller
Quick Start Guide GV-AS Controller Thank you for purchasing GV-AS Controller (GV-AS100 / AS110 / AS120 / AS210 / AS400 / AS810). This guide is designed to assist the new user in getting immediate results
Creation of Waferlock
Creation of Waferlock Established since 1991, Waferlock has initially started its business in firmware design of microcontrollers. With more than a de e of expertise in the electronic design field, the
CISA esigno Contactless Lock
CISA esigno Contactless Lock Innovative Security Solution for Hotels & Resorts Seamless Contactless Wireless esigno Contactless lock CISA esigno is the latest addition to our range of security solutions
ELECTRONIC LOCKING SYSTEMS
ELECTRONIC LOCKING SYSTEMS Electronic Locking Systems Electronic locks for display cases, lockers and sliding doors This small intelligent electronic cabinet lock has a wide range of uses. Based on a
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273
Arcus-EDS Product Description LCD-Color-Display
Arcus-EDS Product Description 010 ,, Article Nr: 200111xx (x: 0=without panel; 3=with V2A-panel) (x: 1=white; 2=anthracite) The LCD Display communicates with different devices of the modern electric installation
Wireless Data Logger Monitoring Systems
Wireless Data Logger Monitoring Systems Table of Contents About MadgeTech, Inc. Wireless Systems & Components Wireless Data Loggers 2000A Wireless Data Logger Models MadgeTech Cloud Services MadgeTech
USB-500/600 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
1 Technical Description Lokal-200PC
1 Technical Description Lokal-200PC 1.1 Overview laptop with in-built accummulator USB connection correlator box internal power supply laptop (if the device has been supplied by F.A.S.T.) BNC aerial connection
An intercom completes any access control system by providing a means for the user of screening visitors before granting access, thereby significantly
INTERCOM SYSTEMS An completes any access control system by providing a means for the user of screening visitors before granting access, thereby significantly increasing security. traffic barriers POLOphone
Shunt lock function 3066
Version: January 2004 Contents Alarm System Activation unit Deactivation unit Digital locking cylinder or Smart Relay 1.0 Method of Operation 4 1.1 General 4 1.2 Turning the Alarm System On 4 1.3 Turning
INSTALLATION MANUAL XM3 Reader
INSTALLATION MANUAL XM3 Reader Conditions Transactions, deliveries et cetera will be according to the general terms of delivery as deposited at the Chamber of Commerce at Meppel, The Netherlands. Registration
Controllers. The integrated standard software guarantees highest quality standards! Simple and safe operation. Specific and clear indication
Screwdriving technology Automation Air motors Air tools Controllers Sequence Controllers for Screwdrivingand Assembly Stations The integrated standard software guarantees highest quality standards! Simple
Radio Thermostat Clock Part Number: 30800009. Installation & User Instructions. Suitable for all Ferroli Combination Boilers
Radio Thermostat Clock Part Number: 30800009 Installation & User Instructions Suitable for all Ferroli Combination Boilers 2 Short Description Short description Radio Thermostat Clock - Transmitter The
ABLOY EL420, EL520 Europrofile motor locks
ABLOY EL4, EL5 Europrofile motor locks ABLOY Europrofile locks can be installed with long plates or roses. An ASSA ABLOY Group brand Convenience, High security, High durability - Europrofile motor locks
Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
USB-500 Series Stand-Alone, Low-Cost Data Loggers
Stand-Alone, Low-Cost Data Loggers Features Stand-alone, remote data loggers Measure temperature, humidity, voltage, or current 1 or 2 channels Low cost, small size Battery powered Software Included, easy-to-use
Operating instructions TSE Wireless Software Business +
Operating instructions TSE Wireless Software Business + Contents 1. GENERAL 2 2. INSTALL SOFTWARE 2 2.1. Installation with Windows XP 2 2.2. Installation with Windows Vista 3 3. THE PROGRAM 7 3.1. Setup
AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS
AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS 1 DORANI VIDEO INTERCOM - 2 WIRE SERIES 7 TFT MONITOR TECHNICAL SPECIFICATIONS 7 Colour TFT screen 480 x
ABLOY EXIT. Functional and technical descriptions Single and double leaf doors. An ASSA ABLOY Group brand
SSFN 014/2 2 ABLOY EXIT Functional and technical descriptions Single and double leaf doors An ASSA ABLOY Group brand ABLOY EXIT - EXIT PRODUCTS It is time to take the exit safety standards to a new level.
WPR400 Wireless Portable Reader
P516-098 WPR400 Wireless Portable Reader User guide Para el idioma español, navegue hacia www.schlage.com/support. Pour la portion française, veuillez consulter le site www.schlage.com/support. Contents
Heating oven with mechanical convection
FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous
Installation and User s Manual Global Tracking and Tracing System. GTTS-2000Bi
Installation and User s Manual Global Tracking and Tracing System GTTS-2000Bi Version 1.4 - January 2016 T +31570 606088 E [email protected] W www.gtts.eu Page 1 of 11 1. Preface The information in this Installation
Combi B PC software 8213X. Installation and operating instructions
Combi B PC software 8213X Installation and operating instructions EN Table of Contents 1 Important notes... 3 2 Glossary of abbreviations and terms... 4 3 Symbols and special font types used... 5 4 Scope
Alarm Security Kit - NVR
Alarm Security Kit - NVR EN The alarm configuration menu (see above right screenshot) allows you to configure and change settings for the PIR movement sensors, window/door sensors, remote controls (key
Dialock Keys. Legic or Tag-it TM -ISO. Card holder without short clip. Short clip. www.hafele.com DK 40
Dialock Keys Dialock electronic locking systemdialock KeysPrices Availability OrderingPlanning, Construction KC card Legic or Tag-it TM -ISO Dialock electronic locking systemdialock keyprices Availability
Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6
Alarm over IP IRIS Touch Home Installation Manual Version 1.0 ENGLISH Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 1. Introduction No more bulky batteries, just one sleek unit
garage door operators
garage door operators duo vision separate control unit with integrated interior pushbutton Optional designer control housings other control unit housings with different finishes (ask about further designs)
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
2. DESIGN REQUIREMENTS
2. DESIGN REQUIREMENTS The Smart Lock Security system will give the user the ability to control his or her door lock from the convenience of texting from the user s cell phone. The device can be controlled
Model 201 Wiegand Touchpad Reader Installation Guide
Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without
Inwall 4 Input / 4 Output Module
Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...
XIGHTOR DOOR ENTRY SYSTEM. Company Name company address line 1 company address line 2 www.schneider-electric.com
DOOR ENTRY SYSTEM SE002-0115-00 Schneider Electric - All rights reserved Company Name company address line 1 company address line 2 www.schneider-electric.com As standards, specifications and designs change
Transmitter Actuator 230V wave UP 560. Operation
Transmitter ctuator 230V wave UP 560 5WG3 560-201 Product- and pplication Description Diagram The transmitter actuator 230V wave UP 560 (Diagram ) is a flush-mounted device with radio communication for
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION
ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION 2014 Ferport/Armas has over 30 years been synonymous with technology, reliability and experience in
BLU Vivo 4.3 User Manual
BLU Vivo 4.3 User Manual 1 Table of Contents Phone Safety Information... 3 Appearance and Key Functions... 4 Installation and Charging... 5 Phone Operation... 7 Communication... 10 Camera... 11 Gallery...
P10 - Standalone Access Controller and Reader
www.quantek.co.uk T: 01246 417113 P10 - Standalone Access Controller and Reader 1 Description & Features: P10 is a waterproof standalone access control, reading EM&HID card, it uses advanced Microprocessor,
Introducing... The Word's Most Advance. Biometric Time Attendance Door Access Security System
Introducing... The Word's Most Advance Biometric Time Attendance Door Access Security System EC50 Proximity Card Time Clock Designed for Small to Large sized Businesses Large Color LCD Display Plug n
Two-way communication, keep checking the commnunication between the panel and accessories, make sure the system safer.
Innovative GSM & WIFI dual network operating platform. On WIFI network, the alarm system will work without any fee. If no WIFI, it will work on GSM automatically. With state-of-the-art WIFI network technology,
PROXIMITY CARD READERS C-10, C-20, C60, C70
Installation Manual PROXIMITY CARD READERS C-10, C-20, C60, C70 VERSION 1.0 CONTENTS 1. General information................................. 3 2. Technical data......................... 4 3. Connection
125 8880 telstra.com/ppmbb visit a telstra store or partner GETTING TO KNOW YOUR
FOR MORE INFORMATIoN: 125 8880 telstra.com/ppmbb visit a telstra store or partner GETTING TO KNOW YOUR Telstra PRE-paid 4G wi-fi LET S GET THIS SHOW ON THE ROad WHAT S INSIDE Your Telstra Pre-Paid 4G Wi-Fi
Cable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
18 LITER VOLUME STERILISATION MATERIALS TESTING MEDIA PREPARATION
18 LITER VOLUME STERILISATION MATERIALS TESTING MEDIA PREPARATION Applications THE WIDE RANGE OF USING CERTOCLAV AUTOCLAVES MICROBIOLOGY / BIO-CHEMISTRY Autoclave culture mediums Refuse sterilisation Efficiently
Solution 144 The Integrated Access Control & Alarm System made for your business
Solution 144 Access Control & Alarm System 1 Solution 144 The Integrated Access Control & Alarm System made for your business The Solution 144 Integrated Access Control & Alarm System offers an extensive
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
INSTALLATION GUIDE 1
INSTALLATION GUIDE 1 Setting information MAC-558IF-E address(mac) MAC-558IF-E serial number(id) MAC-558IF-E code(pin) Indoor unit model name Indoor unit serial number Outdoor unit model name Outdoor unit
Adaptability to Enhanced Security
Installer Guide Adaptability to Enhanced Security AdapTec Plus combines power supply and door access controller features in a compact casing for an encrypted and secure I/O function, enhancing door access
Spectra SP Expandable Security Systems
Spectra SP Expandable Security Systems Control Panels Feature Comparison between Spectra SP Control Panels Feature SP4000 SP65 SP5500 SP6000 SP7000 StayD Maximum Zones 32 32* 32* 32* 32* On-board Zones
AutoPay 80. Ticketer and paying machine
AutoPay 80 Ticketer and paying machine The exclusive-looking designed wall mounting ticketer and paying machine primarily used for the smooth service of clients at frequented service centres, the automatic
LABOKLAV. Autoclaves Made in Germany. www.shp-steriltechnik.de
LABOKLAV Autoclaves Made in Germany www.shp-steriltechnik.de 2 LABOKLAV STEAM STERILIZERS Steam sterilization is the sterilization method with the widest range of applications efficient, safe, reproducible
Honeywell Total Connect Video Solutions FAQs
How many cameras can I stream at once, and can I stream cameras in separate windows? You can stream up to six cameras at once (providing you have the required bandwidth). Yes, individual cameras are streamed
User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
ABLOY EL460, EL461, EL560, EL561 Europrofile handle controlled locks
EL460, EL461, EL560, EL561 Europrofile handle controlled locks Europrofile locks offer intelligent solution for medium traffic doors. Locks can be installed with long plates or roses. An ASSA Group brand
Adaptability to Enhanced Security
Installer Guide Adaptability to Enhanced Security AdapTec Plus combines power supply and door access controller features in a compact casing for an encrypted and secure I/O function, enhancing door access