SERIES FRI. Maximum working pressure 20 bar Flow rate to 1200 l/min. s.p.a
|
|
- Christopher Butler
- 8 years ago
- Views:
Transcription
1 SRIS FRI Maximum working pressure bar Flow rate to 1 l/min s.p.a R
2 FRI series filter has been disigned and developed to satisfy the demands pf applications, on return or low preessure line in Hydraulic market. For example: in line & off-line filtration test bench return filtration lubrification system Simbol SRI FRI Working pressure bar D.I. D.I. without y-pass with y-pass CTC FRI UK
3 Caratteristiche tecniche Material owl: y-pass valve : Indicators: Cover: Pressure Working pressure: FRI Fatigue test: Temperature From - C to + 11 C y-pass valve luminium nodized Steel (only for FRI 8) Plastic material rass luminium nodized Nylon (only for FRI ) bar 1.. di cicli from to bar y-pass valve setting:,4 bar ±1% Other pressure settings available. p Microfibre s series: 1 bar Stainless square wire mesh s M series: 1 bar Paper s P series: 1 bar Seals Standard Nitrile (una-n) Viton optional PDM optional serie serie V serie Compatibility with fluids ody, compatible with: Mineral oil according to ISO 94 - water-based emulsions - synthetic fluids, water-glycol. s, compatible with: mineral oil according to ISO 94, synthetic fluids and water-based emulsions. Seals in NR series, compatible with: Mineral oil according to ISO 94 - water-based emulsionswater-glycol Seals in FPM V series, compatible with: Synthetic fluids type HS-HFDR-HFDS-HFDU Weights (Kg.) Volume (dm ) FRI 1,,8 FRI 1,8 1,9 FRI,, FRI 4,, FRI 1,8 7, FRI 8 48, 1, material Series Inorganic microfibra with acrilic support Series P Resin treated paper Series M Squre wire mesh ndcap: Nylon galvanized Internd tube: steel Dirt molding capacit In according ISO 1889: Multi-pass test s, conform to the following ISO standard: ISO Verification of collapse/burst resistence ISO 94 - Integrity of the first bubble point ISO 94 - Compatibility with fluids ISO 7 - Method for end load test ISO 74 - Verification of flow fatigue characteristics ISO 98 - Flow rate ISO Multi-pass method for evaluating filtration performance Supply voltage (V) Vca 1 ( ) Vca ( ) Vcc (=) Vcc 1 (=) Vcc (=) Connector DIN 4 lettrical characteristics for indicator Resistive load Carico (),, lectrical connection Series - N Series K - - N Inductive load (),, lectrical connection Series K N.C. N.. N.C. N
4 General - selection For a quick reference guide, refer to page assembly pressure drop: p Total = p filter housing + p filter Housing pressure drop: The p is proportional to the fluid density. pressure drop: The p is proportional to the kinematic viscosity. The pressure drop data of the filter s reported in this brochure were obtained using mineral oil fluid with a kinematic viscosity of /s (cst). Technical data The curves were obtained using a mineral oil with a density of,8 Kg/dm according to ISO 98. The p is proportional to the fluid density. Housing pressure drop,,4, FRI / /4 1 assembly sizing example p Total pc housing pe Y Factor Q l/min = Flow rate V1 = Reference viscosity /s (cst) V = Working viscosity in /s p Total = pc + pe pe = Y x Q x ( V/V1 ) Per applicazioni con viscosità cinematica diversa da /s (cst) vedi esempio Coefficiente Y per la definizione della perdita di carico degli i filtranti Sizing xample Q = 4 l/min V = 4 /s (cst) - working viscosity Pmax = 1 bar Filtration = µm absolute p Total max =, bar (recoendation) Pressure drop = p max 1 bar pc =,1 bar (* housing pressure drop FRI ) pe =,71 x 4 x ( 4/ ) =,4 bar p Tot. =,1 +,4 =,8 bar selected FRI with filter,,4, 1 1 FRI / 1/ CU -4- Y Factor Y factor for the pressure drop of the individual filter. CU 1 Y Factor series N - M,77,477, ,9,9,1, FRI 8 CU 4,48,1,7,4, 1/ 1 1,8,14,99,8 1 1,,,
5 CU 1- - Y Factor Y factor for the pressure drop of the individual filter. CU 1 CU Y Factor series N - M,11,1,,49,,7,18,,,,14,14,71,98,,1 y-pass valve The curves were obtained using a mineral oil with a density of,8 kg/dm according to ISO 98. The p is propotional to the fluid density. Housing pressure drop FRI FRI CU -8 - Y Factor CU Y Factor series N - M,19,11 4 FRI - 1 1,84,7, ,7,8 CU 8,7,1 FRI ,84,41,,1 4,17,9,
6 assembly Inorganic microfibra FRI CU sempio: FRI 4 G1 1 N P1 V 1 8 sempio: CU 4 1 N P1 Ordering information FRI 1 - Size assembly type FRI Inorganic microfibra µ P1 MP Filtri standard 4 FRI 4 1 FRI 1 Inorganic microfibra µ 1 Inorganic microfibra 1 µ ßx (c) 1 Pxx Customer request 9 - lement condition indicator FRI 1 Inorganic microfibra 1 µ S With threaded hole only FRI Inorganic microfibra µ T With plug FRI Resin-treated paper T With threaded hole and plug (only for FRI ) 8 FRI 8 Z Visual (Pop-up) bar - y-pass valve Square wire mesh V Visual bar With by-pass S Without by-pass - Seals - Collaps p N 1 ar M 1 ar N lectrical bar Visual-electrical bar K* Visual-electrical bar 1-4 Volt - 11 Volt *{ - Volt V NR FPM P 7 ar 7 - for seals VR Visual indicor (only for FRI ) FX lectrical bar (only for FRI ) N NR FK Visual-electrical bar (only for FRI ) V FPM 4 - Porty options Type G1 G 1/ G /4 G 1 G 1 1/ G 1 1/ G 1/ - G 1/ NPT /4 NPT 1 NPT 1 1/ NPT 1 1/ NPT 1/ NPT - G S 8 S 1 S 1 S 4 S 4 S - G G 1 1/4 - - G /4 NPT - - G S - - F S 1 1/ S 1 1/ S 1/ S 1/ S PSI/M PSI/M PSI/M PSI/M PSI/M F S 1 1/ S 1 1/ S 1/ S 1/ S PSI/UNC PSI/UNC PSI/UNC PSI/UNC PSI/UNC MP Filtri - Filtration products will only be guaranteed if original MP Filtri replacement s and spares are used Date help in this publication is given only for indicative purposes. MP Filtri reserves to introduce modification to described items for technical or coercial reasons. Copyright reserved. 8
7 Indicator Led 4, 41 Ch. 4 7 Ch. Z V N K FRI -4 selaction-quick reference guide The following filter sizing recoendations are based on using a mineral oil fluid /s (cst) with a maximum filter assembly (housing & filter ) pressure drop of 1, bar. H1 H D H H7 ø D Ch H4 H H ttacco indicatore This port is supplied with a plug or a blind flange Holes on the tank 9 ø D4 ø D + 1 FRI FRI 4 Type Flow rate I/min Series N * * * 8* 8* 8* * Portata massima consigliata 4 fori ø D Tipo 4 H H 8 98 H 8 H4, H 19 H, 1 H D 8, 11 D 89 1 D D M M 44 7 Thread connections TIPO G1 G G 4 G 1/ G /4 1/ NPT /4 NPT S 8 /4 1 UN S 1 1 1/1 1 UN
8 Indicator Led 4, 41 Ch. 4 7 Ch. Z FRI 1-- H7 V N Ch ttacco indicatore K selaction-quick reference guide The following filter sizing recoendations are based on using a mineral oil fluid /s (cst) with a maximum filter assembly (housing & filter ) pressure drop of 1, bar. H1 H H D Tipo H1 H H H4 1 Thread connections ø D H H H H H4 D TIPO G1 G G 1 G 1 1 NPT S 1 1 /1 1 UN G 1 1/ G 1/ 1 1/ NPT S 4 1 7/8 1 UN 1/ NPT S 1/ 1 UN H This port is supplied with a plug or a blind flange D C 4 fori ø D D D 9 ø D4 ø D + 1 D M M8 M1 Holes on the tank 8 117, Flange connections Tipe 1 F1 F F1 F F1 F FRI 1 FRI FRI Type Connections 1 S PSI/M 1 S PSI/UNC 1 1/ S PSI/M 1 1/ S PSI/UNC 1/ S PSI/M 1/ S PSI/UNC Flow rate I/min Series N 1* 1* 1* 1* C ,19,7,19,7,71 9,8,71 9,8,8 88,9,8 88, * 8* 8* 8* * Portata massima consigliata D1 M1 /8 UNC M1 1/ UNC M1 1/ UNC
9 Indicator Led 4, 41 Ch. 4 7 Ch. Z V N K FRI 8 Ch ttacco indicatore selaction-quick reference guide The following filter sizing recoendations are based on using a mineral oil fluid /s (cst) with a maximum filter assembly (housing & filter ) pressure drop of 1, bar. FRI 8 Type Flow rate I/min Series N 4 48 C ø 7 ø 18 D 1* 1* 1* 1* * Portata massima consigliata Flange connections Connections 1/ S- PSI/M 1/ S- PSI/UNC 9,9 9,9 C 1,7 1,7 D M1 /8 UNC 178 Holes on the tank 9 9 ø 9 ø 7 4 fori M14 7
10 Indicator VR FK FX Led SCL - R Ch11 UNI-ISO 7/1 Rc 1/8 8 8 ø4 9 ø9 Ch 4 R 1/8 UNI-ISO 7/ ø9 Ch 4 R 1/8 UNI-ISO 7/1 FRI Ch ttacco indicatore selaction-quick reference guide The following filter sizing recoendations are based on using a mineral oil fluid /s (cst) with a maximum filter assembly (housing & filter ) pressure drop of 1, bar. 1 1 ø1 4 D,71 9,8 FRI Type 1 1 Flow rate I/min Series N * Portata massima consigliata 88 Holes on the tank ø 174 R 1/8 9 ø 1 ø 18 9 ø 8, 4 fori M8 Thread connections TIPO G1 G G G4 G G G 1 1/ 1 1/ NPT S 4 G 1 1/4 1 1/4 NPT S Flange connections Connections 1 1/ S- PSI/M 1 1/ S- PSI/M D M1 1/ UNC 8
SERIES FRI. Maximum working pressure 20 bar F l o w r a t e t o 1 2 0 0 l / m i n. s. p. a
New Headquarters : MP FILTRI S.p.. Italy Via 1 Maggio, n. Pessano con ornago (Milano) Italy Tel. +9./97.1 Fax +9./9741497-974188 email: sales@mpfiltri.com http://www.mpfiltri.com GRT RITIN MP FILTRI U.K.
More informationOUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter
D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from
More informationThe SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.
D e s c r i p t i o n 500 The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron. A major feature of these
More informationNew. absolute filter elements independently tested in the following Institutes: MPH-MPI 02050/7.99/USA 2 COVER INSERT
e s c r i p t i o n MPH and MPI series filters are designed for returnline applications and provide various installation applications. The filters are installed semiimmersed or totally immersed into a
More informationGREAT BRITAIN CANADA MP FILTRI U.K.
New eadquarters: MP FILTRI S.p.. Italy Via Maggio, n. 0060 Pessano con Bornago (Milano) Italy Tel. +9.0/9570. Fax +9.0/957449795788 email: sales@mpfiltri.com http://www.mpfiltri.com GRET BRITIN MP FILTRI
More informationReturn line filters. Return line filters
Return line filters Return line filters Index Technical data - 5 Filters series 6 Filters series --3 8 ccessories Spare parts Uni-ardan Italia S.p.. reserves the right to make technical changes to the
More informationMHT. Pressure Filters HIGH PRESSURE INLINE FILTER
MHT Pressure Filters HIGH PEUE INLINE FILTE Pressure Filters MHT MHT 4 MPa ( bar) Port sizes: / / Flow rates: 0 l/min TEHNIAL DATA Max. working pressure: 4 MPa ( bar) Max. testing pressure: 6 MPa (60 bar)
More informationBGAH Series. Medium Pressure Filters Max. 500 l/min. 25 bar. In-line solution for a straight pipeline. Applications: Contact Information:
BGAH Series Medium Pressure Filters Max. 500 l/min. 25 bar In-line solution for a straight pipeline Pre-filtration by magnet column and a full-flow bypass with low hysteresis. Contamination-proof in-out
More informationFilter Elements E 7.200.9/05.06
HYDAC Filter Elements safeguard the performance and service life of essential and expensive hydraulic components due to their high standard of quality Filter Elements Technical details: Absolute filtration
More informationEco130 Series. Medium Pressure Filters Max. 1400 l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:
Eco130 Series Medium Pressure Filters Max. 1400 l/min. 30 bar Modular system for industrial applications High flow return filters for industrial use on hydraulic or lubrication systems. High flow and pressure
More informationEco130 Series. Medium Pressure Filters Max. 1400 l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:
Eco130 Series Medium Pressure Filters Max. 1400 l/min. 30 bar Modular system for industrial applications High flow return filters for industrial use on hydraulic or lubrication systems. High flow and pressure
More information15/40/80CN Series Medium Pressure Filters
1/4/8CN Series Medium Pressure Filters Max 32 l/min - 7 bar Global Filtration Technology 1/4/8CN Series TYPICAL APPLICATIONS Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard)
More informationHOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999
CONTAMINATION CONTROL in hydraulic systems in the hydraulic system is a very wide and complex matter; the following is just a short summary. Our Customer Service is at your disposal for any further information.
More informationHFS and HFD Series. High Flow Single and Duplex Filters Max. 11200 l/min. 10 bar. Heavy Duty Reliability. Applications: Contact Information:
High Flow Single and Duplex Filters Max. 11200 l/min. 10 bar Heavy Duty Reliability New High Flow Single and Duplex Filters ensure reliability in industrial, marine, and power generation applications up
More informationE4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51
83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE
More informationSCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.
SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of
More informationDuplex Filters 40 FLDK 0008(C)-0120(C)
Industrial Filters Accumulators Duplex Filters 40 FLDK 0008(C)-0120(C) Filters for inline installation for continuous operating Ball valve change over Optimised flow characteristics by 3D computer aided
More informationReusable contamination basket prevents loss of retained contaminants into the reservoir during element replacement.
APPLICATION RETURN LINE FILTERS Series RF & RFD Pressures to 36 PSI Flows to 3 GPM HYDAC RF and RFD In-Tank Return Line Filters are designed for use on hydraulic power units, machine tools, plastics machinery,
More informationTanktop Mounted Return Line Filters. BGT Series. MAX 2400 I/min - 10 bar LEIF LEIF FILTER FEATURING AN INNOVATIVE GREEN. Low pressure filters
GT Series X 2 I/min - bar N INNOVTIV GRN FITR FTURING IF IF 2 ow pressure filters GT Series Features & enefits Features bar rated filter ast aluminium head IF elements agnetic pre-filtration In-to-Out
More information15/40/80CN Series Medium Pressure Filters Max. 600 I/min - 70 bar
1/4/8CN Series Max. 6 I/min - 7 bar Premium performance for medium pressure applications FEATURING An economical multipurpose filter solution The CN Series utilizes a cast aluminium head and spin-on bowl
More information15/40/80CN Series Coreless Medium Pressure Filters
//8CN Series Coreless Medium Pressure Filters //8CN Series Applications Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard) Hydrostatic Drive Charge Pumps Mobile Equipment Pilot
More informationD634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05
D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05 GENERAL SECTION PAGE MOOG SERVO- AND PROPORTIONAL CONTROL VALVES General 2 enefits and Functionality 3 General
More informationSOLENOID VALVES 3-4 WAY
SOLENOID VLVES - WY IE/C// CT: FP/VCR Page: 7 SHEET: / SOLENOID VLVES - - WY CV SOLENOID VLVES -WY/-POSITION /- UNF.7 5.7 The electric valve is a -way -position directional electrically controlled Slight
More informationPUMP AND MOTOR DIVISION
INSTALLATION MANUAL SERIES P2 and P3 MOBILE PISTON PUMP 1 Check model code / compare with your paper work Nameplate of the pump Ordering / Sales Acknowledgement 2 Check rotation of the pump Clockwise rotation
More informationDuplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400. Industrial Filters Accumulators. Filters for inline installation for continuous operation
Industrial Filters Accumulators Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400 Filters for inline installation for continuous operation With integrated pressure equalisation valve Optimised flow
More informationIndicators Series FPC
Indicators Series FP Max 40 bar Global Filtration Technology FP TYPIAL APPLIATIONS Industrial Equipment Mobile Equipment Marine/Offshore Applications ompetitor Housing The FP range of filter condition
More informationQPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems
The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system
More informationOpen center control block in monoblock design MO-40
Open center control block in monoblock design MO-40 RE 64370 Edition: 02.2015 Replaces: 02.1985 Size 40 Series 1X Maximum working pressure on pump side 350 bar on consumer side 420 bar Maximum flow 680
More informationChapter 5: Flow Valves
Catalogue HY11-300/UK Contents Chapter : Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 06 10 16 Throttle valves, manual adjustment MVI -2 NS -4 FS With free
More informationLEIF LEIF. BGT Series. Tanktop Mounted Return Line Filters Max. 2400 I/min - 10 bar. Patented LEIF elements safeguard filtration quality
GT Series Tanktop ounted Return ine Filters ax. 24 I/min - bar atented IF elements safeguard filtration quality When high flow performance is needed N INNOVTIV GRN FITR FTURING IF IF The GT Series features
More information3/2-way Mini Solenoid Valve
3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug
More informationIn-Tank Mounted Return Line Filters. IN-AGB Series. MAX 2400 I/min LEIF LEIF FILTER FEATURING AN INNOVATIVE GREEN. Low pressure filters
MAX I/min AN INNOVATIVE GREEN FILTER FEATURING LEIF LEIF Low pressure filters Features & Benefits Features Filter integrated in tank LEIF elements Magnetic pre-filtration In-to-Out filtration igh level
More informationFluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
More informationTurbine Flow Sensor Series VTR
Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates
More informationSafety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage
Safety for Hydraulics Leak free double check valve, pilot operated, series Cartridge type, two stage 8 1 1 General description spring closed, pilot operated, cartridge type poppet valve it holds the load
More informationDXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30
85 320/215 ED DXPE*J DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK SUBPLAtE MOUNtINg DXPE5J CEtOP P05 DXPE5RJ ISO 4401-05 (CETOP R05) DXPE7J ISO 4401-07 (CETOP 07) DXPE8J ISO 4401-08
More informationFluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.
Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power
More informationPOWER PULSE VALVES remote pilot threaded or Quick Mount connection 3/4 to 1 1/2
POWR PULS VLVS pilot threaded or Quick Mount 3/4 to 1 1/2 N 2/2 Series 353 TURS The piston cartridge pulse valves are especially designed for dust collector service applications, combining high flow, long
More informationChapter 6: Check Valves
Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Shuttle valves SSR -2 Check valves, direct operated RK / R CS SPZE SPV
More informationCartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)
Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers
More informationPipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
More information2/2 and 3/2 Way Size 6 Seat Valves
2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08
More informationHigh Pressure Filters. 70/70 Eco Series. MAX 450 I/min -420 bar FEATURING. High pressure filters
7/7 Eco eries MAX 5 I/min - bar FEATURING 5 High pressure filters 7/7 Eco eries Features &enefits Features Fatigue tested to full pressure rating everal head options and connection sizes everal bowl lengths
More informationSafety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage
Safety for Hydraulics Leak free check valve, pilot operated, series Cartridge type, two stage prevents a load from falling if a burst occurs in feed pipe hardened seat and poppet prevents creep of hydraulically
More information2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow
2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description
More informationSAFETY BLOCK type BS 9.3 E 01-12
SAFETY BLOCK type BS 9.3 E 01-12 9.3.1 TECHNICAL DATA MAX OPERATING PRESSURE (PS): 420 bar PRESSURE TEST (PT): 1.43 x PS NOMINAL PASSAGE DIAMETER: 10mm, 20mm, 25mm, 32mm WORKING TEMPERATURE: -40 +150 FLUID
More information3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow
1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control
More informationFlow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB.. 1.1 Generals. 1.2 Application examples. 2.2 3-way flow control. 2.1 2-way flow control
Flow Control Valve Series SRCB.. plug-in solenoid for easy coil change flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports energy - optimised
More informationVARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications
VARIABLE DISPLACEMENT AXIAL PISTON PUMPS For truck applications TVP FEATURES Variable displacement axial piston pumps swash plate design ideally suited for open circuit truck applications. The compact
More informationWater Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C
Water droplet removal Water Separator Water droplet separation rate: % Model Flow capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure 300 750 1,500 AMG 2,0 AMG to AMG/ Large dust particle
More informationPressure reducing valve, direct operated, Type ZDR 6 D
RE 26 57/2.3 Replaces:.2 Pressure reducing valve, direct operated, ype ZDR 6 D Nominal size 6 Series 4X aximum operating pressure 2 bar aximum flow 5 L/min K 4279/ ype ZDR 6 DP2 4X/ Y Overview of contents
More informationSolenoid valves 2/2-way direct-operated Type EV210A
Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral
More informationPRE3G 81 250/212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12
81 250/212 ED PRE3G PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS SUBPLATE MOUNTING ISO 4401-03 (CETOP 03) p max 350 bar Q max 40 l/min MOUNTING SURFACE OPERATING
More informationMicro oil-mist lubricator, Series NL2-LBM G 1/4
Version Micro oil-mist lubricator, an be assembled into blocks Mounting orientation vertical Working pressure min./max. 0.5 bar / 6 bar Medium ompressed air Neutral gases Medium temperature min./max. -0
More information3/2 Solenoid Cartridge Valve, Size 6
/ Solenoid Cartridge Valve, Size 6 Q max = l/min, p max = 5 bar Bidirectional seat-valve shut-off, direct acting Guided valve spool and poppet Two spool variants are available Available in two mounting
More informationUSA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI 53072 U.S.A. Tel: 262-691-2222 FAX: 262-691-0312 E-mail: sales@dynexhydraulics.
SPECIFICATIONS PF1000 Series Fixed Displacement Pumps Also refer to "Checkball Pump Installation and Operating Recommendations" Bulletin PSI.CB (dynexpumpinstallation.pdf) CONTACT INFORMATION USA Headquarters
More informationSingle sub-base valve
solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet
More informationAssisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
More information2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:
More informationVariable Displacement Pump AA10VSO
Variable Displacement Pump AA10VSO Series 31, Industrial Model, for Open Circuits Axial piston, swashplate design Brueninghaus Hydromatik Sizes 28...140 Nominal pressure 4000 psi Peak pressure 5100 psi
More informationProportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32
www.atos.com Table F040-1/E Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 AGMZO are two stage poppet type proportional
More informationDenotes New Winner s Circle Product Line. Catalog HY15-3502/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY
Catalog HY-5/US Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI HIGH FLOW VALVE FAMILY See individual catalog pages for exact specifications. WAY SPOOL TYPE GS *... X / C9-.. Position,
More informationNORMAN FILTER COMPANY PRODUCT OVERVIEW
NORMAN FILTER COMPANY PRODUCT OVERVIEW LEADING THE WAY IN QUALITY FILTRATION WWW.NORMANFILTERS.COM FILTER ELEMENT INTERCHANGE Tee-Type Filter 4500, 14500, 34500, and 54500 Series Mini Tee-Type Filter 4100
More informationPiston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.
SK Series Piston Types TYPE 2 pplication: Low-friction design for higher piston speeds, slow movements without stick-slip effect and high number of actuations (millions). ctual cycles achieved will vary
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationPressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
More informationRMF TANDEM 900 OFF-LINE FILTER SYSTEMS
RMF TANDEM 900 OFF-LINE FILTER SYSTEMS RMF Tandem 900 Off-line filter Systems can be applied to every imaginable industrial application where hydraulic or lubrication systems are present. An integrated
More informationWorking Pressure up to 630 bar / 9135 PSI
Test Hoses SMS / SS + Working Pressure up to 630 bar / 9135 PSI Technical Data for Test Hose A B C D Nominal Bore () (mm) Max. Working Pressure (PN) (bar / PSI) 00 / 5801 630 / 9135 30 / 931 630 / 9135
More informationSPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4
SPOO & SV VAVS monostable / bistable function threaded ports -G 1/ 5/-5/3 Series 1 FATURS Reliability: steel spool & sleeve technology with long service life Robust valve design, particularly recommended
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationPressure relief valves Size 6
Pressure relief valves Size 6 direct controlled Interface to DIN 24 340 and ISO 6264 PN [p max. ] = bar 750400.06.0.06 Description (standard units) Design The pressure relief valves of Type D B C 6 are
More informationMobile Hydraulic Pumps T6*M. Denison Vane Technology, fixed displacement
Mobile Hydraulic Pumps T6*M Denison Vane Technology, fixed displacement Contents GENERAL Series T6 Mobile, Denison Vane Pumps Features...3 Instructions...3 Minimum & maximum speeds...4 Pressure ratings...4
More informationElectromagnetic pump designation GOTEC
Electromagnetic pump designation GOTEC E T S 21 - E : In beginning of the designation for all pumps based on the Electromagnetic principle. 1 T : means the complete square motor (coil + metallic frame
More informationKDG3V-5/7/8, 10 Series
Vickers roportional Valves KDG3V-5/7/8, 1 Series Single-Stage with Hydraulic ilot Operation High Flow roportional Directional Control Valves asic Characteristics Max. pressure.......... up to 35 bar (5
More informationStandard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve
Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective
More information12CS Series Coreless Spin-on Filter Max. 75 l/min - 35 bar
2CS Series Coreless Spin-on Filter Max. 7 l/min - 3 bar Environmentally friendly alternative for spin-on filtration Lightweight, non-metallic element that can be incinerated The 2CS Series features a Parker,
More informationPILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V
PILOT OPERTED PRESSURE RELIEF VLVE - Series VR4V The Veljan Pressure Relief Valve series VR4V are pilot operated and wk Internal Dra on the prciple of hydraulic balancg. These valves are used to limit
More informationUM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves
U/ / or / > > Sub-base mounted, 99- s,, or > > Steel reinforced main seals > > Low power coils (,W) > > Wide range of sub-bases and accessories > > 6 bar and bar NOO solenoid pilots with locking or non-locking
More informationVickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93
Vickers Check Valves Check Valves Inline, right angle, manifold mounted, and pilot operated designs Released 9/93 645 Introduction Vickers inline, right-angle, and manifold mounted check valves are direct
More information4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
More informationInrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.
Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the
More informationUM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted
U/ / & / valves, solenoid and pilot actuated ISO 99-, ISO size,, & Sub-base mounted Steel reinforced main seals 6 bar and bar NOO solenoid pilots with locking or non-locking manual override Low power coils
More informationFRL/AirCare Air Controls & Accessories
FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More informationPPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
More informationWATER & OIL 12/24v DC ELECTRIC CIRCULATION PUMPS
WATER & OIL 12/24v DC ELECTRIC CIRCULATION PUMPS BAT Inc. 7630 Matoaka Road., Sarasota, FL. 34243 (941) 355-0005 fax (941) 355-4683 Heavy Duty Oil Scavenge/Circulation Pump When high temperature and continuous
More informationHose and Tube Fittings Series 1-3
Embracing Challenge Hose and Tube Fittings Series 1-3 out of plastics PP, PVDF, PTFE Series 1 Special Features Corrosion resistant Gas tight Easy to handle Different connection threads Application Hose
More informationSQUARE D INDUSTRIAL CONTROL PRODUCTS
SQUARE D INDUSTRIAL CONTROL PRODUCTS CLASS 9012 3a INDUSTRIAL PRESSURE SWITCHES Type A Heavy duty switch for virtually any industrial application involving air, water, steam or oil Bellows, piston and
More informationShut-off & Lockout Valves 1/4" to 1-1/2" port size
Section 16 Shut-off & Lockout Valves 1/4" to 1-1/2" port size Contents T72 Excelon Shut-off & Lockout Valves 1/4", 3/8" Port Sizes....................................ALE-16-2 T73 Excelon Shut-Off & Lockout
More informationPressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations
VICKERS Pressure Relief Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 Sectional Illustrations RCG-** Model Shown RCT-** Model Shown Basic Characteristics Type...................
More informationSporlan V-Series Ruby Seat Solenoid Valves
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Sporlan V-Series Ruby Seat Solenoid Valves RACE Catalogue 30-10-8 UK,
More informationThermostatic valve Type AVTA
MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The
More informationDSE5J 83 280/112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO 4401-05 (CETOP 05)
83 280/112 ED DSE5J DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO 4401-05 (CETOP 05) p max 320 bar Q max 180 l/min MOUNTING SURFACE OPERATING
More informationElectrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)
Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports
More informationCheck Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits
Vickers Check Valves Pilot Operated Check Valves PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series Typical Section Typical PCG5V model with internally drained pilot piston internal leakage through the closed pilot
More informationD660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10
D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10 OVERVIEW D660 Section Page MOOG SERVO-PROPORTIONAL CONTROL VALVES Overview 2 3 Technical Data 4 5 Electronics
More informationG1/4 Q8. Standard with biased position
Contents Version Actuation Page Characteristics Dimensions x / Way Valves pneumatic 6,7, 0 9 electric 6,7 9, 9 / Way Valves pneumatic 6,7, 0 electric 6,7, 0 / Way Valves pneumatic 6,7,, 6, 7 electric 6,7,,
More informationPrecision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.
Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.
More informationSolenoid Operated Directional Valves
INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SF-2C-115A-35 S-1AY-12D-35 SD-2C-12D-35 Features High Flow/ High Pressure: Up to 40 gpm / 5000 psi working pressure*.
More information