1 Measuring and monitoring units VAMP 96
2 Measuring and monitoring units Main characteristics Intelligent measuring and monitoring units The VAMP and WIMO meters come with an extensive selection of pre-configured data screens and measurements that you can use or customize to fit your metering requirements. Cost Allocation and Billing Determine consumed energy by production cost centers according to the EU s Energy Service Directive (ESD) 2006/2/EC. Demand and Power Factor Control Avoid penalties with automated load shedding, scheduling, peak shaving or capacitor bank control Equipment Monitoring and Control Improve process yields and extend equipment life. Extensive analog and digital I/O enables system monitoring and control. Power quality and Disturbance Analysis Capturing abnormal disturbances in power quality like harmonics, voltage interruptions, voltage sags/swells and unbalancing. Preventative Maintenance Set up alarms to warn of pending problems in advance Extensive communication and SCADA connectivity IEC 61850, IEC , IEC , Modbus TCP, Profibus DP, DNP.0, DNP TCP, SPA, MBus (VAMP 96) Remote or stand-alone monitoring of industrial and utility substations VAMP 96 and for industrial and utility applications VAMP 96 and metering devices are designed for industrial and utility applications where energy consumption and billing shall be monitored by cost centers or individual feeder. Demand and power factor control, equip-ment monitoring, alarms for preventive maintenance and disturbance capturing are standard features in VAMP 96 and. As a member of VAMP protection relay family these meters come with an extensive communication capabilities. for utility applications meters are optimized for the utility applications suitable for secondary power distribution substations. The load monitoring and fault detection on the power distribution network is very important part of the real time maintenance and fault tracking sequences. Distribution transformers have been installed without supervision or with stand-alone metering in the past. meters can also be stand-alone but with optional communication facilities these devices can be connected to network control centers for continuous supervision 2
3 A right product for every application Solution VAMP 96 Operational segment Industrial and Industrial and Utility secondary utility substations utility substations power distribution Application Power, energy, Power, energy, Power, energy and power quality metering, power quality metering, power quality metering, event handling and event handling, earth fault detection, I/O unit for SCADA and control, alarming, alarming, process automation temperature monitoring and temperature monitoring, I/O unit for SCADA and process automation alarm and load profile SCADA transfer over GSM, GPRS CT and VT input Metering core Metering or Metering core connection protection core Auxiliary supply range V ac 18 6 V dc V ac V dc or V dc or V dc / ac V dc Number of digital inputs 6 Number of RTD inputs - Optionally Number of heavy trip contacts Number of alarm contacts Number of ma outputs Number of solid state outputs 1 pc NO 1 pc NO / NC
4 Measuring and monitoring units Product Overview VAMP 96 measuring and monitoring unit The VAMP 96 is a modern basic multimeter used as a stand alone meter in industrial low and medium voltage power distribution distribution panels. This meter can be connected to SCADA or energy management system in order to provide required measurements, alarms, condition data, events to the operator using various communication protocols. VAMP 96 shall be connected to measurement core of the current and voltage transformers Typical application of VAMP 96 is to measure energy by production cost centers and to show energy savings. VAMP 96 is a basic multimeter used either stand-alone or part of monitoring / SCADA system power monitoring unit The is designed for a heavy duty industrial applications where the environmental and disturbance conditions are demanding. This power monitoring unit can be connected to the protection cores of the current and voltage transformers as the design of the unit is equal to the requirements used in protection relays. Having six digital inputs, two circuit breaker controlling, four alarming duty contacts and four analogue ( ma ) outputs this unit is unique in the market. measuring and monitoring unit The is optimized for the utility applications especially for the secondary power distribution substations. The secondary power distribution transformers can now be monitored either stand alone or remotely using various communication protocols and channels. The distribution transformer stations located either in the rural area or basements of the houses can be taken cost effectively to the continuous monitoring from the electrical, water or transformer oil level, temperature, door switch, ventilation, burglar, graffiti spraying detection point of view to name a few typical monitored quantities. is a unique high accurate meter as it can be connected to either protection or measurement core of the current transformers. is used either stand-alone or it is connected to the supervision system of the utility s secondary power distribution network. 4
5 VAMPSET setting and configuration tool VAMPSET is a user-friendly, free-of-charge relay management software for setting, parameterising and configuring of VAMP relays. Via the VAMPSET software relay parameters, configurations and recorded relay data can be swapped between the operator s PC and the VAMP relays. Supporting the COMTRADE format VAMPSET also incorporates tools for analyzing relay events, waveforms and trends from data recorded by the relays, e.g. during a network fault situation. Using a standard RS cable the PC running VAMPSET connects to the front or rear port of the VAMP / WIMO devices. The VAMPSET software also supports TCP/IP communication via an optional 10Base-T connection. Featuring true multi-language support the software runs on Windows 7/Vista / XP / 2000 / NT / 98 / 95 without any need for configuration of the PC. The VAMPSET software is future-safe supporting coming updates and new VAMP products. The VAMPSET software size is about 1 Mbytes; you may conveniently distribute it by saving valuable transport and waiting time and money. Measurement view in VAMPSET of unit. A disturbance recorder view from indicating a faulty cable termination from the incoming feeder of paper mill s supply. This recording gave pre-information hence the repair action was possible before the cable termination faulted. VAMPSET shows on-line the content of voltage and current distortion from each phase measured by the VAMP and WIMO meters. Measured and calculated values come straight from the databases of the VAMP and WIMO meters. As a regular feature of the VAMP and WIMO units, standard COMTRADE type disturbance recording files can be uploaded for subsequent evaluation of any network event recorded. 5
6 Measuring and monitoring units Functionality 6
7 Communication Various communication alternatives to our demand As VAMP 96 and are members of VAMP protection relay family the meters benefit of the communication protocols widely used in other VAMP devices. The metering and control devices are often interfaced with Profibus DP, MODBUS TCP, Modbus RTU or SPA communication in industrial applications. Utilities request IEC 61850, IEC , IEC , DNP.0 and SPA protocols. In addition to this, the VAMP 96 has a MBus protocol in order to support connectivity with the Automatic Meter Management (AMM) systems. WIMO s connectivity to SCADA The WIMO s SCADA connection solution allows monitoring of the secondary substations over the internet. An ASP contract makes the commissioning of the WIMO fast and easy as the users of the system does not require any hardware at Network Control Center (NCC) side. Ready-made event, alarm, setting and measurement views are informative and the system enables transfer of data for instance to Word, Excel, html and txt format for further analysis. SCADA, DCS or SA system Maintenance Terminal Control and status of the process Events Measurements Fault location Time synchronizing using GPS Relay settings, configuration Fault and disturbance analysis Power quality monitoring Primary equipment condition monitoring Time synchronizing using GPS * IEC , IEC ,Modbus RTU, Modbus TCP, Profibus, SPA, DNP.0, DNP TCP or IEC Physical Media: RS 485 RS 22 Fibre optic Ethernet TCP / IP, RS 485 or fibre OPC client WIMO s SCADA connection OPC server OPC client RMU Secondary Substation MV/LV SCADA LAN (TCP/IP) RMU Secondary Substation MV/LV GSM/GPRS modem RMU Secondary Substation MV/LV Cost effective communication media The most efficient communication media from the secondary substations are GMS, GPRS, leased modem line or fiber optical communication. Using the WIMO-GSM communication only three messages a day is required to transfer all measurements to Network Control Center. Leased modem line or GPRS allows real time data transfer cost efficiently. GSM/GPRS modem Measuring and Monitoring Unit GSM/GPRS modem Measuring and Monitoring Unit GSM/GPRS modem Measuring and Monitoring Unit 7
8 Measuring and monitoring units Connection diagrams L1 L2 L connection diagram P 2 AO 1 AO 2 AO AO 4 P 1 X X X is connected to phase voltages in a 400 V network is connected to line voltages in a 400 V network 8
9 10kV VAMP 96 connection diagram R 10/0.4kV X2B:1 X2B:2 Uaux ~ VAMP 96 Measurement functions Local X4 X2A:2 N Remote X2A:5 X2A:4 U1 U2 V A Hz X X2A: U N L1 L2 L VA W var P.F cosfii tanfii X1:1 X1:2 X1: X1:4 X1:5 X1:6 IL1 IL2 IL Wh varh THD U&I harmonics Relay out General digital inputs X2B: DI1 X2B:4 DI2 X2B:5 DI X2B:8 +12V DI X2A:7 X2A:8 Energy pulse output VAMP96_LVCON_2 I 0 connection diagram o C X2A:1 Uaux ~ Local X4 Measurement functions X2A:2 N Remote X2A:5 X2A:4 U1 U2 ~ ~ V A Hz X X2A: U PEN L1 L2 L X2B:1 X2B:2 Io VA W var P.F cosfii tanfii X1:1 X1:2 IL1 Wh varh THD X1: X1:4 IL2 X1:5 X1:6 IL U&I harmonics X2B: DI1 X2B:4 DI2 X2B:5 DI DI Relay out X2A:8 X2A:9 X2A:7 X2B:8 +12V PT100 X2B:6 X2B:9 X2B:7 WIMO6CP10_WIRECON_2 + - VOLTAGE SUPPLY TO GSM 9
10 Measuring and monitoring units Typical applications Wimo 6CP10 is optimal metering and monitoring unit for utility s secondary power distribution substations I 0 Remote Control Center VAMP 96 VAMP 96 is a basic metering and control device used for measuring power and energy of production cost centers in industrial applications. The same meter can be used by the utilities for detecting consumed energy per feeder. 110/10kV Energy Management System 10kV 20/0.4kV o C Modbus, Profibus DP, TCP/IP I U ALARMS I U Vamp96 I U Vamp96 VAMP 96 VAMP 96 10/0.4kV 10/0.4kV power monitoring unit applied for monitoring of power and energy at industrial power distribution. Energy pulses drive Energy Management System whereas the alarms and load information goes via the serial communication to the Control Center. The ma outputs control analogue meters of the switchgear. Remote Control Center Energy Management System Serial communication Energy pulses 10
11 Order codes Accessories VAMP 96 1 C 7 Nominal current [A] 1 = 5 A Nominal Voltage [V] C = V Frequency [Hz] 7 = 50/60 Hz Supply voltage [V] A = Vac/dc B = Vdc G = Vdc Optional hardware A = None O = LC 100 Mbps interface inc. IEC and M-bus P = RJ Mbps ethernet interface inc. IEC and M-bus Optional hardware A = Version 6 firmware** B = Note: (** Only optional hardware, A available 1 C 7 A Nominal current [A] 1 = 1 A Nominal Voltage [V] C = V Frequency [Hz] 7 = 50/60 Hz Supply voltage [V] A = Vac/dc Optional hardware A = None O = LC 100 Mbps interface inc. IEC and M-bus P = RJ Mbps ethernet interface inc. IEC and M-bus Optional hardware A = B = Nominal current [A] 1 = 1 A 5 = 5 A Nominal Voltage [V] C = V Frequency [Hz] 7 = Standard relay Supply voltage [V] A = Vac/dc B = Vdc Optional hardware (communication port 1) A = None B = C = D = RS 485 interface (4-wire) E = F = G = H = RJ-45 10Mbps ethernet interface M = RJ-45 10Mbps ethernet inc. IEC O = LC interface inc. IEC P = RJ Mbps ethernet interface inc. IEC R = interface inc. IEC S = 2 x RJ Mbps ethernet interface inc. IEC A = # B = # C = D = E = F = Note: ( * Optional hardware, A-H available (# Optional hardware, A-G available Order code Description Note VEA CGi External Ethernet Interface Module VPA CG VSE001 Fiber optic Interface Module VSE002 RS485 Interface Module VSE00 RS485 Interface Module, Ext I/O interface VSE004 RS485 Interface Module, Ext I/O interface VSE009 External DeviceNet interface module VIO 12 AB RTD Module, 12pcs RTD inputs, RS 485 Communication (24-20 Vac/dc) VIO 12 AC RTD/mA Module, 12pcs RTD inputs, PTC, ma inputs/outputs, RS22, RS485 and Optical Tx/Rx Communication (24 Vdc) VIO 12 AD RTD/mA Module, 12pcs RTD inputs, PTC, ma inputs/outputs, RS22, RS485 and Optical Tx/Rx Communication (48-20 Vac/dc) VX00- RS22 programming cable (Vampset, VEA CGi) Cable length m VX028- Cable length m VX02- Back panel programming cable Cable length m VX00- Interface cable to VEA CGi (Ethernet module) Cable length m VX004-M TTL/RS22 converter cable (PLC, VEA CGi) Cable length m VX007-F TTL/RS22 converter cable (VPA CG) Cable length m VAM 16D External LED module Disables rear local communic sensor Earth-fault current sensor Cabletroll WIMOTEMP Pt100 Pt100 sensor Cable length 5 m sensor Short-circuit sensor Horstman VYX076 Raising Frame for 200-serie Height 40 mm VYX077 Raising Frame for 200-serie Height 60 mm VYX2 Raising Frame for 200-serie Height 100 mm V200WAF V200 wall assembly frame VAMP 96 11
12 Measuring and monitoring units Dimensional drawings All dimensions in mm. power monitoring unit Semi-flush mounting b a Panel mounting Depth with raising frames Type designation a b VYX mm 169 mm VYX mm 149 mm VYX mm 109 mm 19.0 > PANEL CUT-OUT 12
13 VAMP 96 and measuring and monitoring units Measuring and Monitoring Unit X 96,0 ALARM POWER C E 90,0 96,0 96,0 X X2A VY091 90, X2B 88,0 96,0 107,0 TOP 89,0 mm 91,0 mm VY101C 96,0 107,0 Panel cut-out 18,0 12,5 150,5 9,0 Connection label VAMP 96 L1 L2 L N PULSE OUT L1 L2 L PEN RELAY OUT NO / NC X2A X2A X1 X2B X1 X2B U BINARY INPUTS I 0 BINARY INPUTS PT100 VOLTAGE SUPPLY TO GSM VY108B 1
14 Measuring and monitoring units Technical data, tests and environmental conditions Measuring circuitry VAMP 96 Rated current In 1 A or 5 A 1 A or 5 A 1 A or 5 A - Current measuring range 1 x In 0-5 x In 0 1 x In - Thermal withstand 1,2 x In (continuously) 4 x In (continuously) 1,2 x In (continuously) 20 x In (for 10 s) 100 x In (for 1 s) - Burden < 0.1 VA (In = 1 A) < 0.1 VA (In = 1 A) < 0.1 VA (In = 1 A) < 0.2 VA (In = 5 A) < 0.2 VA (In = 5 A) < 0.2 VA (In = 5 A) Rated voltage Un V V (configurable) 20 V - Voltage measuring range V V V - Continuous voltage withstand 264 V 275 V 275 V - Burden < 0.5V A < 0.5V A < 0.5V A Rated frequency fn Hz Hz Hz - Frequency measuring range Hz Hz Hz Terminal Block: Max. wire dimension: Max. wire dimension: Max. wire dimension: - Solid or stranded wire 2,5 mm 2 (1-14 AWG) 4 mm 2 (10-12 AWG) 2,5 mm 2 (1-14 AWG) Auxiliary voltage Type A (standard) Type B (option) Type A (standard) Type B (option) Rated voltage Uaux V ac/dc V dc V ac/dc 18-6 V dc V ac/dc 110/120/220/240 V ac/dc 24 V dc 110/120/220/240 V ac/dc 24 V dc 110/120/220/240 V ac/dc V dc 48/60/110/125/220 V V dc dc Power consumption 5 W (normal conditions) < 7 W (normal conditions) 5 W (normal conditions) < 15 W (output relays activated) Max. permitted interruption time < 50 ms (110 V dc) Terminal Block: Max. wire dimension: Max. wire dimension: Max. wire dimension: - Phoenix MVSTBW or equivalent 2.5 mm 2 (1-14 AWG) 2.5 mm 2 (1-14 AWG) 2.5 mm 2 (1-14 AWG) Digital inputs Number of inputs 6 Operation time s (step 0.01 s) s (step 0.01 s) s (step 0.01 s) Polarity NO (normal open) or NC (normal closed) NO (normal open) or NC (normal closed) NO (normal open) or NC (normal closed) Inaccuracy: - Operate time ±1% ±1% ±1% Internal operating voltage 12 V dc 48 V dc 12 V dc Current drain when active (max.) Approx. 5 ma Approx. 20 ma Approx. 5 ma Current drain, average value < 1 ma Terminal block: Max. wire dimension: Max. wire dimension: Max. wire dimension: - Phoenix MVSTBW or equivalent 2.5 mm 2 (1-14 AWG) 2.5 mm 2 (1-14 AWG) 2.5 mm 2 (1-14 AWG) Trip contacts Number of contacts - 2 making contacts - Rated voltage V ac/dc - Continuous carry - 5 A - Max. making current - 15 A - Breaking capacity, AC VA - Breaking capacity, DC (L/R=40ms) - 50 W - Contact material - AgNi 90/10 - Terminal Block: Max. wire dimension: - Phoenix MVSTBW or equivalent mm 2 (1-14 AWG) - Accuracy Current +/- 0.4 % of value when I > 0.5 x In +/- 0. % of In +/- 0.4 % of value when I > 0.5 x In Voltage +/- 0.5 % of value +/- 0.5 % +/- 0.5 % of value Frequency: +/- 10 mhz +/- 10 mhz +/- 10 mhz Active power +/- 1 % of value +/- 1 % of value +/- 1 % of value Reactive power +/- 1 % of value +/- 1 % of value +/- 1 % of value Active energy +/- 1 % of value +/- 1 % of value +/- 1 % of value Reactive energy +/- 1 % of value +/- 1 % of value +/- 1 % of value 14
15 Alarm contacts VAMP 96 Number of contacts 1 normally open change-over contacts 1 change-over contact (A1) (relays A1, A2 and A) 1 change-over contact (IF relay) Rated voltage 48 V ac/dc 250 V ac/dc 48 V ac/dc Max. make current 120 ma 15 A N.O. 10 A / N.C. A Continuous carry A 5 A A Breaking capacity, AC VA N.O VA / N.C. 500 VA Contact material - AgNi 0.15 goldplated AgAl 0.15 goldplated Terminal Block: Max. wire dimension: Max. wire dimension: Max. wire dimension: - Phoenix MVSTBW or equivalent 2.5 mm 2 (1-14 AWG) 2.5 mm 2 (1-14 AWG) 2.5 mm 2 (1-14 AWG) Local serial communication port Number of ports 1 on front and 1 shared 1 on front and 1 on rear panel 1 on front and 1 shared with remote on rear panel with remote on rear panel Electrical connection RS 22 RS 22 RS 22 Data transfer rate kb/s kb/s kb/s Remote control connection Number of ports 1 shared with local port on rear panel 1 on rear panel 1 shared with local port on rear panel Electrical connection RS 22 (standard) TTL (standard) RS 22 (standard) TTL RS 485 (option) TTL RS 485 (with external module) RS 22 (option) RS 485 (with external module) Plastic fibre connection (with ext. module) Plastic fibre connection (option) Plastic fibre connection (with ext. module) Data transfer rate kb/s kb/s kb/s Protocols ModBus RTU master ModBus RTU master GSM ModBus / TCP ModBus / TCP GPRS SpaBus, slave SpaBus, slave SpaBus, slave IEC IEC IEC IEC IEC IEC IEC IEC IEC Profibus DP (option) Profibus DP (option) Profibus DP (option) MBus MBus TCP/IP (option) DNP or Ethernet DNP or Ethernet DNP.0 Analogue outputs Number of Ports - 4 (Note: common +pole) - Electrical connection: - Current output - - Range ma (min & max configurable) - - Load - <800 W - - Accuracy - <±20mA - Isolation test voltage Vdc - Test voltages Insulation test voltage 2 kv, 50 Hz, 1 min 2 kv, 50 Hz, 1 min 2 kv, 50 Hz, 1 min (IEC ) Surge voltage (IEC ) 5 kv, 1.2/50 ms, 0.5 J 5 kv, 1.2/50 ms, 0.5 J 5 kv, 1.2/50 ms, 0.5 J Environmental conditions Operating temperature -25 to +50 o C -10 to +55 o C -25 to +50 o C Operating temperature (display) 0 to +50 o C 0 to +50 o C Transport and storage temperature -10 to +60 o C -40 to +70 o C -10 to +60 o C Relative humidity < 75 % (1 year, average value) < 75% (1 year, average value) < 75% (1 year, average value) < 90 % (0 days per year, < 90% (0 days per year, < 90% (0 days per year, no condensation permitted) no condensation permitted) no condensation permitted) Casing Degree of protection (IEC 60529) IP20 IP20 / Flush mounted IP54 IP20 Dimensions (W x H x D) 96 x 96 x 151 mm 208 x 155 x 26 mm 96 x 96 x 151 mm Material Polyphenylene Oxide 1 mm steel plate Polyphenylene Oxide Weight 0.6 kg 4.2 kg 0.6 kg Color code RAL 702 (Casing)/RAL 705 (Back plate) Package Dimensions (W x H x D) 180 x 100 x 101 mm 215 x 160 x 275 mm 180 x 100 x 101 mm Weight (relay, package and manual) 0.7 kg 5.2 kg 0.7 kg 15
16 With its headquarters in Finland, Vamp Ltd specialises in protection relays, arc flash protection and measuring and monitoring units for power systems. Vamp s medium-voltage and sub-transmission protection relays are used in a number of applications, from overhead line feeders and substations to power plants and industrial power system. Their unique integrated arc flash fault protection functionality enhances the safety of both people and property and has made Vamp a leading brand in arc flash protection worldwide. Vamp is a member of Schneider Electric, a global specialist in energy management. Our success is based on competitive standard products, constant development by our designers possessing experience from three protection relay generations, our long-term partnerships, flexibility and 24 hour care of the customers. Our organization has been audited and found to be in accordance with the requirements of the ISO 9001 management system. Vamp Ltd P.O.Box 810 FI VAASA Finland Visiting address: Vaasa Airport Park Yrittäjänkatu 15 Vaasa, Finland We reserve the rights to product alterations without prior notice. Copyright Vamp Ltd. All trademarks are the property of their respective holders. Tel: Fax: [email protected] VB260.EN007 06/2012
Medium voltage arc flash eliminator units VAM 3ED,
Medium voltage arc flash eliminator units VAM 3ED,, Medium voltage arc flash eliminator units Medium voltage arc flash eliminator units The new innovative arc eliminator VAM 3ED is an extremely fast acting
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
Applications. diris_826_a_1_gb_cat
Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
Substation Automation Products Relion 670/650 series IEC and ANSI Hardware
Substation Automation Products Relion 670/650 series IEC and ANSI Hardware ABB Group 1MRG014097 October 2013 Relion 670/650 series hardware Contents Relion 670/650 series Relion Hardware Relion Common
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
Electrical Network Management System
Electrical Network Management System Optimisation of the electrical network Measure to understand Understand to control Control to optimise Cost of power and fluids Power quality Power availability 2 Improvement
Remote monitoring & control solutions for cathodic protection rectifier
G Remote monitoring & control solutions for cathodic protection rectifier FF-Automation Finnish automation manufacturer company Focused on remote monitoring & control solutions AutoLog RTU Series AutoLog
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
Eaton s E-Series protective relay family
E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family
Power monitoring unit type VAMP 260
Power monitoring unit type VAMP 260 formerly known as VMAC 260 Slide 1 / 18 The complete source of information Slide 2 / 18 The complete source of information Users - utilities -industry - power plants
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...
A project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
Catalog. Arc Guard System TM TVOC-2
Catalog Arc Guard System TM TVOC-2 Introduction An even better Arc Guard System TVOC-2, ABB s latest Arc Monitor, builds on the well known TVOC design. Its new functions and features improve an already
Multilin EPM 6000. GE Grid Solutions. High Accuracy Power & Energy Measurement. Monitoring & Metering. Advanced Communications.
GE Grid Solutions Multilin EPM 6000 High Accuracy Power & Energy Measurement The Multilin EPM 6000 is one of the industry s highest performance revenue grade panel meters with superior cost to performance
Capacitor Protection Relay SPAJ 160 C. Product Guide
Issued: April 1999 Status: Updated Version: C/19.04.2006 Data subject to change without notice Features One-, two- and three-phase overload stage with definite time characteristic One-, two- and three-phase
Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management
Energy Depot GmbH Delivering Solutions for Energy Management PRODUCT AND APPLICATION GUIDE Total Monitoring Solution for PV SOLAR LOGGER & ANALYSIS DC STRING MONITORING Residential Comprehensive Solar
Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11
Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks. The MPU handles the absolute time and
Station Automation Series COM600 Protection and control from ABB Future-proof Concept: Extensive Substation System Integration and Interoperability The Station Automation Series COM600 is a dedicated system
TrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
Thermal Centers Monitoring. Offer of converters TRM102, TRM202, TRM112, TRM212 and additional options.
Thermal Centers Monitoring Offer of converters TRM102, TRM202, TRM112, TRM212 and additional options. Communication with ECL200/300 via Ethernet / GSM / GPRS / MODBUS_TCP TRM102, TRM112 TRM202, TRM212
DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.
SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
SCADA and Monitoring for Solar Energy Plant
SCADA and Monitoring for Solar Energy Plant Segment: Industry Country: Thailand Author: Ranon Satitpanyapan Products: NI LabVIEW with LabVIEW Real-Time Module crio Real-Time controller 8 slot with 16 current
ABB RTU560A Series CMU & Modules
ABB RTU560A Series CMU & Modules 1KGT 150 648 V1.02 March 4, 2012 Slide 1 Contents RTU560A rack solutions March 4, 2012 Slide 2 560CSR01 Available for wall mounting and swing frame Supports redundant power
Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution
Medium Voltage Products ZN1 12 kv arc-proof air-insulated switchgear for primary distribution ZN1 an innovative switchgear for power distribution requirements ABB ZN1 primary distribution switchgear is
T 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager
New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager 2 1SDC200039B0201 New SACE Emax 2 for UL 1066 Circuit breakers switch power SACE Emax 2 manages it. SACE Emax 2 is the new benchmark of
ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface
ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850
Communicate and view data from meters with one simple device
Communicate and view data from meters with one simple device PowerLogic EGX300 integrated gateway-server Web Monitoring Communications Plug and Play Plug into your energy usage with a simple mouse click
IntesisBox Modbus Server Fidelio IP
IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master
TX2123 RS485 TO ETHERNET ADAPTOR
TX2123 RS485 TO ETHERNET ADAPTOR Converts Datacomms between fibre optic Modbus TCP over Ethernet and hard-wired copper Modbus RTU over RS485 Fibre Optic MODBUS TCP/ IP Ethernet Copper MODBUS RTU RS485
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
Permissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219
Siemens AG 2010 Flow Measurement Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track)
TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES
SED-635 Digital Excitation System SED-635 is a complete excitation system capable of adapting to control synchronous generators of any size. The integration of the TOUCH SCREEN operator interface and a
Technical Information POWER PLANT CONTROLLER
Technical Information POWER PLANT CONTROLLER Content The Power Plant Controller offers intelligent and flexible solutions for the control of all PV power plants in the megawatt range. It is suitable for
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks
SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks Introduction SCADA (Supervisory Controlled and Data Acquisition) controlled multi-step metalenclosed automatic capacitor
Panel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
TECHNICAL DESCRIPTION OF THE DISTRIBUTION SUBSTATION REMOTE MONITORING SYSTEM
HELLENIC ELECTRICITY DISTRIBUTION NETWORK OPERATOR S.A. NOTICE OF CALL FOR TENDERS No ND-xxx PROJECT: Pilot Telemetering and Management System for the Electric Power Supply Demand by Residential and Small
Trip circuit supervision relay. Type RXTCS
Trip circuit supervision relay Type RXTCS ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while
Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS
Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking Auto Accident Report Global Position System (GPS) Navigation System Anti theft Alarm System Overview 1. GPS data tracking via GSM
Current and voltage measuring relays
Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application
SCADAPack 530E 535E. remote Programmable Automation Controller
SCADAPack 530E 535E remote Programmable Automation Controller 1 With the SCADAPack 500E range, Schneider Electric introduces the first ever remote Programmable Automation Controller (rpac). This data sheet
Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation
DS 500 Intelligent chart recorder for compressed air and gases Measurement - control - indication - alarm - recording - evaluation new Advantages at a glance: Clear layout: 7" colour screen with touch
Uninterruptible Power Supply
96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
HCR3.2/.. Chipcard reader HOTEL SOLUTION
s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages
Designed for the needs of automation, telecommunications, remote supervision, and monitoring
- Programmable automation controller (PAC) MADE IN EU is a series of industrial computers which you can easily adapt to your needs by choosing from the available options. Energy-efficient ARM11 700 MHz
OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B
OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B The OVR-3SP three-phase recloser style guide aids in the proper selection of your OVR-3SP style number. The OVR-3SP
Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.
Proud Partners with MOBATime GPS or DCF 77 MOBA-NMS (Network Management Sy The new multipurpose time server for the LAN and NTP-based Distributed Time System by MOBATIME DTS 4138.timeserver The DTS 4138.timeserver
Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server
Gain energy insight and control with PowerLogic PowerLogic EGX300 integrated gateway-server Plug into your energy usage with a simple mouse click The PowerLogic EGX300 is an integrated gateway-server that
Arc Terminator Active Arc-Resistant Switchgear
Arc Terminator Active Arc-Resistant Switchgear Increasing safety and productivity by extinguishing internal arcing faults within the switchgear. The Square D Arc Terminator from Schneider Electric offers
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
Feeder protection. for overhead lines and cables in isolated neutral or compensated networks. Specification
Feeder protection for overhead lines and cables in isolated neutral or compensated networks Specification Feeder protection for overhead lines and cables in isolated neutral or compensated networks Version
TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.
TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection
NEW. EVEN MORE data acquisition and test stand automation
NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
MNS is Switchgear System Technical Overview
Switchgear System Technical Overview Innovative Design ABB s innovative MNS is concept combines the long term experience, energy efficiency, grid reliability and industrial productivity of the well-known
Technical Data. back-up time in minutes 100% load 6 7 0 5 6 0 5 0 50% load 15 18 0 15 16 0 15 0
The protectoq is a On-Line double conversion UPS-system according to IEC / EN 62040-3 (VFI-SS-111) with sinus wave output voltage in each operation mode, LCDindication, RS232 interface, USB-connection,
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
Nu-Lec Training Modules
PTCC Controller Nu-Lec Training Modules Product Training Operator Training PTCC The Basics An overview of the construction and physical features of the Pole Top Control Cubicle PTCC Operation and Features
FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid
Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars Presented By: Greg Pelster & Robert Schmid FFI Ferrie, Franzmann Industries LOW VOLTAGE SWITCHGEAR & LOW VOLTAGE
Relion 605 series. Self-powered feeder protection REJ603 Product Guide
Relion 605 series Relion 605 series Relion 605 series Self-powered feeder protection Product Guide Product version: 3.0 Contents 1.... 3 2. Relay functions... 3 3. Protection functions... 4 4. Application...
IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network
IPThermo206G Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network IPThermo 206G is the central data handling terminal of the IPThermo Pro measurement network. This
Solutions for E-Mobility
Solutions for E-Mobility Qatar PHOENIX CONTACT in dialog with customers and partners worldwide Phoenix Contact is a worldwide market leader in the field of electrical engineering, electronics, and automation.
PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions
PMCS Integrated Energy Management Solution Unlock the Full Potential of Power Networks Through Integration Power Management Control System (PMCS) is a highly customizable, fully integrated end-to-end Energy
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
Current Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear
Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear Index 3 Overview 4 Standard Levels 6 Monitoring & Control 7 Measurements 8 Protection & Logic
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
M2M The measure of efficiency
M2M The measure of efficiency The importance of control Measurement and advanced analysis of electrical parameters To make equipment as efficient as possible, it is essential to know the details of its
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
Current Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
Set for PROFINET IO in IP20 TI-BL20-EN-PN-4
Cable max. 50 m between interface and read/write head Connection of up to 4 read/write heads via BL ident extension cables Mixed operation of HF and UHF read/ write heads Connectors /S2500 Type code Ident
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
T200, PTP/IEEE 1588 Grandmaster Clock and
T200, PTP/IEEE 1588 Grandmaster Clock and NTP Time Server with high accuracy GPS receiver, OCXO or Rubidium oscillator 1 Bd d Armor 22300 LANNION - FRANCE [email protected] 1 HEOL-T200 : PERFORMANCE
OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F
OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F The OVR three-phase recloser style guide aids in the proper selection of your OVR three-phase style number.
Optimize your simple machines... Modicon M218 Selection Guide
Optimize your simple machines... Modicon M218 Selection Guide Compact Solution for Simple Machines Optimized Logic Controller Modicon M218 With intelligent software platform, specialized functional s,
Ponto Series. A new concept for automation
Ponto Series A new concept for automation Programmable Controller Remote I/O for Field Buses Special models of I/O modules Web connection Ponto Series Programmable Controller High connectivity CPUs Direct
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter
ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.
NXL Series Inverters. HVAC Inverters made simple
NXL Series Inverters HVAC Inverters made simple Honeywell s Voice Of the Customer process unveils a range of requirements expressed by specifiers and installers, that are ideally covered by the NXL inverter