Building Green Data Centres for World's largest Biometric based National Identification System

Size: px
Start display at page:

Download "Building Green Data Centres for World's largest Biometric based National Identification System"

Transcription

1 Building Green Data Centres for World's largest Biometric based National Identification System Kumar Alok, IAS Deputy Director General Ranjan Kumar Assistant Director General Unique Identification Authority of India (UIDAI) September 13

2 Contents UIDAI - Overview What is UID (Aadhaar)? UID Eco - System The UID Technology Solution Data centre Planning Green Data centre - Selecting efficient solution Improved energy Efficiency & Savings PUE; Power Usage Effectiveness Drivers of PUE UID (Aadhaar) Progress and Status Page 2

3 Unique Identification Authority of India (UIDAI) Overview UIDAI is an attached office under Planning Commission of India which develops and implements the necessary institutional, technical and legal infrastructure to issue unique identity numbers to Indian residents. AADHAAR is a 12-digit unique number given by UIDAI to Indian residents as a proof of identity Enrolment is a one time process for the resident to obtain Aadhaar UIDAI s two captive data centres shall host the; Residents basic demographic and biometric 1 information captured by UIDAI while issuing 12-digit AADHAAR number. Support to various applications for welfare 2 schemes of State & Central Governments Authentication services to various authentication User Agencies e.g; Central 3 Government Agencies / bodies / departments, State Governments, PSUs, Banks etc DC Location-A DC Location-B Page 3

4 What is UID (Aadhaar)? Key Features Only Numbers No Smart Cards Random Numbers No Intelligence, No Profiling All Residents Including Children Uniqueness Ensured through biometric attributes No Guarantees to Citizenship, Rights, Entitlements Ubiquitous Authentication From No ID to Online ID Ensuring Security and Privacy of Information Details Captured Demographic Details Name, age/date of birth, gender and address of the resident (compulsory) Biometric Photograph, fingerprint scan, iris Aadhaar is a 12-digit unique number issued after biometric (iris and fingerprint) and demographic de-duplication Enrolment Hierarchy UIDAI Reg. Offices Registrars Enrolment Agencies Enrolment Stations Apex Body Across the country State Govts., NPR, banks etc Empanelled by UIDAI, engaged by registrars Across the country Residents ~40, Bn Page 4

5 UID Eco - System About 200 Enrolment agencies have been empanelled Details available on UIDAI website Demographic standards - DDSVP report Biometric committee report published Authentication API, micro-atm standards STQC Device certification Applicable for authentication of identity and Financial Inclusion o Banks o NREGA o Payment of pensions Empanelment of EAS Setting standards Authentication Agency/User Ecosystem development Logistics/ India Post Training and Certification Contact Centre Letter printing by 3 printers & delivery by India Post Contact Centre live-8 languages Verifiers and Introducers Operator certification- >155,000 Training content available online-cbt, Films etc 15 empanelled training agencies Page 5

6 The UID Technology Solution It encompass all application software, system software, infrastructure (including IT systems, Private Cloud of Data centres, Network, Servers and Storage, for production, staging and testing) It shall enable to issue UID numbers, update resident information and authenticate the identity of residents as required Page 6

7 Data centre Planning Key decisions (1/2) Key decision points Site selection and land acquisition for two data centres across different geographies Business requirements & IT road map for 1.6 Billion UID enrolments till 2030 Uptime availability? Selecting Tier I/II/III/IV based on business criticality? What cost? High electricity power consumption expenses 5yrs electricity expense ~ CAPEX + 5yrs OPEX* Vertical/horizontal expansion and number of floors in the building * (OPEX- Manpower and equipment maintenance cost) Page 7

8 Data centre Planning Key design considerations (2/2) Guidelines Design Considerations Building Design Data Centre Building to be based on LEED practices for energy efficiency Design based on ASHRAE guidelines Adopting key design guidelines from TIA-942 Tier-III certification from Uptime for data centre LEED certification (Gold) for data centre complex Design based on latest NFPA code and standards Efficient system design at partial load utilization Modular & scalable system design and provision for seamless integration Selected 3 types of rack density (6.5/9.5/13.5 kw) for efficient load utilization & separate room for respective rack density High Avg. rack density (7.8 kw) to optimize space Selecting an highly efficient solution and technology Achieve lowest annual average PUE (< 1.55 /1.6 at Indian environmental condition) conditions) as as per per Green Grid Grid Methodology DC 24*7 24x7 monitoring and measurement DG Fuel bulk storage tank (36hrs) & 2hrs Fire Rating Continuous security and protection from unforeseen or natural calamities Selected tier III DC at each location on the basis of business criticality analysis Building structural floor slab strength 1500kg/ Sq Mtr Clear floor height > 4.7 Mtr Physical Security & perimeter security Seismic zone compliance Page 8

9 Green Data Centre - Selecting efficient solution for better annual average PUE (1/2) Electrical Components 3-phase distribution instead of 1-phase- low power distribution losses Bus Bar Trucking for rack distribution and Main Utility-low power distribution losses PDU transformer with higher efficiency 97.5% IGBT based rectifier transformer less UPS, higher efficiency >95%, low THDi < 3% & higher input PF on partial load Using high efficiency electronic ballasts controlled through occupancy sensors Diversity factor 70% on overall estimated IT load for higher equipment load utilization to have better equipment efficiency Designed for ; Lowest targeted annual average PUE in India 15~20% reduction in PUE vs most of the operational data centres in India ~0.5 MUSD/Year/data centre savings vs most of the operational data centres in India DCIM Components Manage and Measure: Use of data centre infrastructure management software Penalty/Incentive for data centre operation agency on account of exceeding/reducing PUE from the target value Page 9

10 Green Data centre-selecting efficient solution for better annual average PUE (2/2) Air cooled screw chiller selected over water cooled chiller considering Indian environmental conditions : The annual average PUE estimated to be approx 1.6 with air-cooled chiller vs 1.62 with water cooled chiller > 50% IT Load Annual average PUE for Water Cooled chiller marginally better. But there is higher cost of maintenance for water cooled chiller which nullify the effect of marginally better PUE Water availability is a constraint for water cooled chiller as it consumes significant amount of water Mechanical Solutions Higher Chiller efficiency ; Low kw/tr ~.93,COP ~ 3.3 as per ARI design conditions at 100% Load Higher design entering/leaving chiller water temp; 12 / 19 Deg C Use of adiabatic cooling and VFDs for chilled water distribution pumps Separate room for respective very high/high/medium density rack and free cooling used for UPS room & Battery Room Free Cooling/Economizer for server room not used as it requires high CAPEX while energy savings is marginal considering the environmental condition and quality of air in India. Best Practice to be followed BYPASS Air Mgmt - Close floor gaps in unused cabinets & fit cable skirts where cables come up through raised floor Recirculation Air Mgmt- Fit blanking plates in between server cabinets & position high powered servers in the middle (and bottom) of the row Adjust Air Supply Temperatures, raise the air temperature and remain within the ASHRAE recommendations of 64.4F (18 deg C) to 80.6 F (27 deg C). Raising the temperature reduces the overall energy required for cooling Page 10

11 Improved Energy Efficiency & Savings per DC Details per DC: Total IT rack/dc : 420 Avg density/rack :7.8 kw DC built up area : 7,500 sq.m DC white space area : 1,350 sq.m IT rack load : 2300 kw (after considering diversity Mains Power Capacity : 5MVA Potential Annual Savings in optimized solution Saving-Total Cost 5.8 MUSD Saving- Electrical expense cost 6.9 MUSD Increase-CAPEX 0.9MUSD Mains electricity saved annually in DC 4064 with optimized solution MWH (24647 kwh-20583kwh) Metric tones Co2 saved annually in DC 3617 MTn Equivalent Tn Coal annual saving in 1808 Tn tones of coal burned per MWH of thermal energy (Tn/MWH) Trees growing per Year 5,42,289 Saved Co2 emissions equivalent to 603 number of cars per year on the road USD in Million Operational Data Center In India if same size Legend Saving of $5.8 M on Total Cost 15% saving on Electricity Cost 6% increase in CAPEX Optimised Data Center Solution-UIDAI DC CAPEX + 10 yrs OPEX-A (Manpower +Maintenance) OPEX-B (10 Yrs Electricity expense) Total Cost (CAPEX+OPEX-A+OPEX-B) Page 11

12 Power Usage Effectiveness (PUE) A PUE of 2.0 means that for every 2 watts delivered to the Data centre, only 1 watt is being used by the IT equipment.the same as being 50% efficient Data centre Facility and Power : UIDAI DC White Space Support Area Utility Area Server Room IT Load NOC Room On-site User Room Media Storage Room Accessories Room Material Handling Room Staging Room UPS Battery Room Communication Room BMS Room Passage Power Losses Cooling Load Utility Services Room Page 12

13 Key Drivers of PUE- Indicative calculations Climate % Load Utilization India s Temperature Data -Annual Delhi Bangalore <10 Deg C 9% 1% 10~20 Deg C 22% 18% 20~ 25 Deg C 14% 49% 25~30 Deg C 26% 25% 30~35 Deg C 21% 8% 35~40 Deg C 7% 0.2% 40~45 Deg C 1% 0% Source-WeDCoDataBase(wedco-Database.software.informer.com Tier/ Redundancy Measurement Methodology Annual avg. PUE (Unrecognised) in INDIA DC is 1.8 to 2.5 1,63 Annual avg.pue (Self reported) in Global DCs is 1.8 to1.89* 1,62 1,61 Annual avg.pue (targeted) in UIDAI DCs is 1.5 to 1.6 1,6 1,59 5,0% 4,0% 3,0% 2,0% 1,0% 0,0% Tier/Redundancy % PUE increase 0,0% 1,9% 2,5% 4,4% Tier 1 DC Tier-II DC Tier-III DC Tier-IV DC % PUE *Source : Uptime Institute 2012 Data centre Industry Survey by Matt Stansberry and Julian Kudritzki 1,59 1,58 1,57 1,56 1,75 1,5 1,25 1 0,75 0,5 0,25 0 1,75 1,7 1,65 1,6 1,55 External Climate Condition 1,16 Cooling Solution 1,626 Delhi-PUE Water Cooled Chiller 1,38 1,54 1,6 1,66 <12 C 12~17 C 17~22 C 22~27 C 27~32 C 1,7 PUE % Load Utilization 1,605 1,583 Bengaluru-PUE Air Cooled Chiller 25~50% Load PUE >50% 1,6 Page 13

14 UID (Aadhaar) Progress and Status Legend 0-20 (%) 1 September 2010: First Aadhaar issued (%) (%) (%) > 80 (%) December 2011: 100 Million Aadhaar issued February 2012: Launch of authentication services May 2013: Launch of permanent enrolment centres, ekyc & authentication services using Iris & OTP Key Milestones 5 August 2013: 410 Million Aadhaar issued For self-service download UIDAI s Data Centre has been awarded with Tier III Certification of Design by Uptime > 500 Million people have enrolled for UID ~ Million residents being issued UID s daily target to cover more than half of the population by 2014 Page 14

15 Page 15 Questions and Answers

16 Page 16 Thank You

17 Glossary ASHRAE : American Society of Heating, Refrigerating and Air Conditioning Engineers DCIM : Data Centre Infrastructure Manager NFPA : National Fire Protection Association IGBT : Insulated gate bipolar transistor LEED : Leadership in energy & environmental design OTP : One Time Password PDU : Power distribution unit PUE : Power User Effectiveness TIA-942: Telecommunications Infrastructure Standards for Data Centres VFD : Variable Frequency Drive Page 17

18 Global-Average PUE Values The average PUE rating (Self reported) for Data centres is , according to a survey of more than 500 data centres globally conducted by Uptime Institute in the year 2012 covering North America (50%), Europe (23%), Asia (14%), Central and South America (7%) 14% Average PUE Value % Globally 13% 12% 11% 11% 11% 10% 9% 9% 8% 6% 4% 2% 2% 2% 4% 6% 7% 5% 4% 1% 2% 3% 0% > to to to to to to to to to to to to to to or less Source : Uptime Institute 2012 Data centre Industry Survey by Matt Stansberry and Julian Kudritzki Page 18

GREEN DATA CENTER DESIGN

GREEN DATA CENTER DESIGN Jeffrey Menig Global Facilities Facility Engineering The application of multiple available technologies resulting in improved energy optimization without significantly increasing capital investment. A

More information

Building a data center. C R Srinivasan Tata Communications

Building a data center. C R Srinivasan Tata Communications Building a data center C R Srinivasan Tata Communications Introduction Data Center as defined by TIA 942 A building or a portion of a building whose primary function is to house a computer room and its

More information

Green Data Centre Design

Green Data Centre Design Green Data Centre Design A Holistic Approach Stantec Consulting Ltd. Aleks Milojkovic, P.Eng., RCDD, LEED AP Tommy Chiu, EIT, RCDD, LEED AP STANDARDS ENERGY EQUIPMENT MATERIALS EXAMPLES CONCLUSION STANDARDS

More information

AIRAH Presentation April 30 th 2014

AIRAH Presentation April 30 th 2014 Data Centre Cooling Strategies The Changing Landscape.. AIRAH Presentation April 30 th 2014 More Connections. More Devices. High Expectations 2 State of the Data Center, Emerson Network Power Redefining

More information

Biometric Authentication. Biometric Consortium Conference Tampa

Biometric Authentication. Biometric Consortium Conference Tampa Biometric Authentication Biometric Consortium Conference Tampa 18 September 2013 Features of UID (Aadhaar) Authentication Only Numbers No Smart Cards Random Numbers No Intelligence, No Profiling All Residents

More information

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America 7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer

More information

esign Online Digital Signature Service

esign Online Digital Signature Service esign Online Digital Signature Service Government of India Ministry of Communications and Information Technology Department of Electronics and Information Technology Controller of Certifying Authorities

More information

Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM)

Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM) Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM) Salim Janbeh Physical Infrastructure Consultant uae-sj@panduit.com PANDUIT You Can t Manage What You Don t Measure:

More information

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Dealing with Thermal Issues in Data Center Universal Aisle Containment Dealing with Thermal Issues in Data Center Universal Aisle Containment Daniele Tordin BICSI RCDD Technical System Engineer - Panduit Europe Daniele.Tordin@Panduit.com AGENDA Business Drivers Challenges

More information

World s Greenest High Performance Data Center

World s Greenest High Performance Data Center World s Greenest High Performance Data Center EcoDataCenter Sustainability for future generations Our Services Colocation Data Center for Mission Critical Requirements Lockable racks, cages, private rooms

More information

BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0

BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0 BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0 To achieve GREEN MARK Award Pre-requisite Requirement All relevant pre-requisite requirements for the specific Green Mark Rating are to be complied

More information

High-density modular data center making cloud easier. Frank Zheng Huawei

High-density modular data center making cloud easier. Frank Zheng Huawei High-density modular data center making cloud easier Frank Zheng Huawei 2012-10-10 Content 1 2 3 4 Cloud s impact to data center Concerns of DC construction 4S DC making cloud easier Success stories Cloud?

More information

Managing Data Centre Heat Issues

Managing Data Centre Heat Issues Managing Data Centre Heat Issues Victor Banuelos Field Applications Engineer Chatsworth Products, Inc. 2010 Managing Data Centre Heat Issues Thermal trends in the data centre Hot Aisle / Cold Aisle design

More information

Data Center Energy Profiler Questions Checklist

Data Center Energy Profiler Questions Checklist Data Center Energy Profiler Questions Checklist Step 1 Case Name Date Center Company State/Region County Floor Area Data Center Space Floor Area Non Data Center Space Floor Area Data Center Support Space

More information

ICT and the Green Data Centre

ICT and the Green Data Centre ICT and the Green Data Centre Scott McConnell Sales Manager c/o Tanya Duncan MD Interxion Ireland Green Data Centres Our Responsibility Data centre greenhouse gas emissions are projected to quadruple by

More information

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint Energy usage in the data center Electricity Transformer/ UPS Air 10% Movement 12% Cooling 25% Lighting, etc. 3% IT Equipment

More information

Specialty Environment Design Mission Critical Facilities

Specialty Environment Design Mission Critical Facilities Brian M. Medina PE Associate Brett M. Griffin PE, LEED AP Vice President Environmental Systems Design, Inc. Mission Critical Facilities Specialty Environment Design Mission Critical Facilities March 25,

More information

Enabling an agile Data Centre in a (Fr)agile market

Enabling an agile Data Centre in a (Fr)agile market Enabling an agile Data Centre in a (Fr)agile market Phil Dodsworth Director, Data Centre Solutions 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without

More information

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity SmartDesign Intelligent, Integrated Infrastructure For The Data Center Solutions For Business-Critical Continuity Prepare Your Data Center For What s Next Efficiency. Availability. Capacity. Control. One

More information

Energy Efficiency and Availability Management in Consolidated Data Centers

Energy Efficiency and Availability Management in Consolidated Data Centers Energy Efficiency and Availability Management in Consolidated Data Centers Abstract The Federal Data Center Consolidation Initiative (FDCCI) was driven by the recognition that growth in the number of Federal

More information

Scalable. Affordable. Flexible. Fast.

Scalable. Affordable. Flexible. Fast. Modular Data Center Solutions Scalable. Affordable. Flexible. Fast. Build the data center you need today with the flexibility to meet tomorrow s challenges The only constant in business is change. Fluctuations

More information

How green is your data center?

How green is your data center? Siemens Answers: Sustainable Future How green is your data center? Istanbul June 01, 2010 Agenda 1 Solution 2 Siemens Data Center Approach 2 Designing with multiple power density zones can reduce energy

More information

Data Center Infrastructure Management: ERP for the Data Center Manager

Data Center Infrastructure Management: ERP for the Data Center Manager Data Center Infrastructure Management: ERP for the Data Center Manager 1 2 Topics What s DCIM & the ERP Analogy Why DCIM How DCIM Works How DCIM Helps 3 DCIM by Definition DCIM is a system that collects

More information

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management. AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled

More information

WORLD CLASS, GLOBALLY CERTIFIED, HIGH AVAILABILITY DATA CENTRE INTELLICENTRE 2 MACQUARIE PARK, SYDNEY

WORLD CLASS, GLOBALLY CERTIFIED, HIGH AVAILABILITY DATA CENTRE INTELLICENTRE 2 MACQUARIE PARK, SYDNEY WORLD CLASS, GLOBALLY CERTIFIED, HIGH AVAILABILITY DATA CENTRE INTELLICENTRE 2 MACQUARIE PARK, SYDNEY A NEW GENERATION OF DATA CENTRE SOLUTIONS AUSTRALIA S FIRST SHOWCASE TIER III CERTIFIED DATA CENTRE

More information

ALWAYS ON GLOBALSWITCH.COM

ALWAYS ON GLOBALSWITCH.COM ALWAYS ON GLOBALSWITCH.COM Data Centre Design Considerations Kelvin Fong Managing Director, Hong Kong ALWAYS ON GLOBALSWITCH.COM Agenda 1. Introduction to Global Switch 2. Customer Requirements 3. Development

More information

Overview of Green Energy Strategies and Techniques for Modern Data Centers

Overview of Green Energy Strategies and Techniques for Modern Data Centers Overview of Green Energy Strategies and Techniques for Modern Data Centers Introduction Data centers ensure the operation of critical business IT equipment including servers, networking and storage devices.

More information

Re Engineering to a "Green" Data Center, with Measurable ROI

Re Engineering to a Green Data Center, with Measurable ROI Re Engineering to a "Green" Data Center, with Measurable ROI Alan Mamane CEO and Founder Agenda Data Center Energy Trends Benchmarking Efficiency Systematic Approach to Improve Energy Efficiency Best Practices

More information

CIBSE ASHRAE Group. Data Centre Energy Efficiency: Who, What, Why, When, Where & How

CIBSE ASHRAE Group. Data Centre Energy Efficiency: Who, What, Why, When, Where & How CIBSE ASHRAE Group Data Centre Energy Efficiency: Who, What, Why, When, Where & How Presenters Don Beaty PE, FASHRAE Founder, President & Managing Director DLB Associates Consulting Engineers Paul Finch

More information

Modular Data Centre. Flexible, scalable high performance modular data centre solutions. Data Centre Solutions...energy efficient by design

Modular Data Centre. Flexible, scalable high performance modular data centre solutions. Data Centre Solutions...energy efficient by design Data Centre Solutions...energy efficient by design Modular Data Centre Flexible, scalable high performance modular data centre solutions Creating an effective workspace environment The Modular Data Centre

More information

CYRUSONE COMPANY OVERVIEW BUILT FOR TOMORROW. READY TODAY.

CYRUSONE COMPANY OVERVIEW BUILT FOR TOMORROW. READY TODAY. CYRUSONE COMPANY OVERVIEW BUILT FOR TOMORROW. READY TODAY. ABOUT CYRUSONE GLOBAL DATA CENTER FACILITIES. A Global Leader 24 high performance data centers worldwide Servicing 9 of top 20 Global Fortune

More information

CRITICAL COOLING FOR DATA CENTERS

CRITICAL COOLING FOR DATA CENTERS IDEA 100 th Annual Conference & Trade Show CRITICAL COOLING FOR DATA CENTERS Presented by Ron Johanning, PE, LEED AP Mission Critical Market Leader Agenda EPA Report Data Center Energy Trends IT Best Practice

More information

VISIT 2010 Fujitsu Forum Europe 0

VISIT 2010 Fujitsu Forum Europe 0 VISIT 2010 Fujitsu Forum Europe 0 Virtualization & Automation Room 13a Shaping tomorrow with you. Green Data Center Services Martin Provoost Director, Data Centers and Networks, Fujitsu UK & Ireland 14:00

More information

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers CURBING THE COST OF DATA CENTER COOLING Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers OVERVIEW Compare Cooling Strategies in Free- Standing and In-Building

More information

Server Technology, Inc.

Server Technology, Inc. Server Technology, Inc. Cabinet Power Monitoring, Management & Control Within the Data Center White Paper STI-100-011 2010-Sept-27 by Calvin Nicholson, Senior Director Software and Strategic Alliances,

More information

Improving Data Centers Energy Reliability & Efficiency. December 2015

Improving Data Centers Energy Reliability & Efficiency. December 2015 Improving Data Centers Energy Reliability & Efficiency December 2015 Background The challenges Alternative solutions SATEC approach Advantages Cases Summary Data Centers Energy Challenges Worldwide Data

More information

Implement Data Center Energy Saving Management with Green Data Center Environment and Energy Performance Indicators

Implement Data Center Energy Saving Management with Green Data Center Environment and Energy Performance Indicators Implement Data Center Energy Saving Management with Green Data Center Environment and Energy Performance Indicators Awareness of environmental protection issues, has many industry types focusing and pursuing

More information

Insourcing vs. Outsourcing. Bart Leung Senior Associate, Ehvert Mission Critical

Insourcing vs. Outsourcing. Bart Leung Senior Associate, Ehvert Mission Critical Insourcing vs. Outsourcing Bart Leung Senior Associate, Ehvert Mission Critical 1 Agenda Ehvert Mission Critical Data Centres Then and Now Power & Cooling Considerations Costs Making the Choice 2 History

More information

AADHAAR E-KYC SERVICE

AADHAAR E-KYC SERVICE UIDAI Unique Identification Authority of India Planning Commission, Govt. of India, 3rd Floor, Tower II, Jeevan Bharati Building, Connaught Circus, New Delhi 110001 AADHAAR E-KYC SERVICE NOVEMBER 2012

More information

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009 Optimum Climate Control For Datacenter - Case Study T. Prabu March 17 th 2009 Agenda 2 About EDEC (Emerson) Facility Data Center Details Design Considerations & Challenges Layout Design CFD Analysis Of

More information

European Code of Conduct for Data Centre. Presentation of the Awards 2013

European Code of Conduct for Data Centre. Presentation of the Awards 2013 European Code of Conduct for Data Centre Presentation of the Awards 2013 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport 1 The Code of Conduct for Data Centre Results Started

More information

CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers

CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers CEMEP UPS The high environmental performance solution for power supply to high-availability data centers Exchanges of information and communication needs are growing at an exponential rate. That growth

More information

Infrastructure as a Service

Infrastructure as a Service Infrastructure as a Service Next Generation Data Center & Cloud Paul Chen paul.chen@cskytech.com 2013 Csky Information All rights reserved. Changing More Users More Devices More Data >1 Billion More Netizen

More information

80% of. 50% of. 30% of. 67% of enterprises. Environmental and business demands are converging

80% of. 50% of. 30% of. 67% of enterprises. Environmental and business demands are converging Delivering the Green Datacenter Jerome Riboulon, HP 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice 2 24 Abril, 2008 Environmental and

More information

Data Center Facility Basics

Data Center Facility Basics Data Center Facility Basics Ofer Lior, Spring 2015 Challenges in Modern Data Centers Management, Spring 2015 1 Information provided in these slides is for educational purposes only Challenges in Modern

More information

This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits.

This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits. This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits. DCD, DCOM, DCE DESIGN IMPLEMENTATION BEST PRACTICE OPERATION & MANAGEMENT DATA

More information

Huawei Data Center Facility Integration Solution

Huawei Data Center Facility Integration Solution Huawei Data Center Facility Integration Solution HUAWEI TECHNOLOGIES CO., LTD. As the growing demand for efficiency, flexibility and low-cost, enterprise need a more flexible and efficient data center

More information

The Mission Critical Data Center Understand Complexity Improve Performance

The Mission Critical Data Center Understand Complexity Improve Performance The Mission Critical Data Center Understand Complexity Improve Performance Communications Technology Forum Fall 2013 Department / Presenter / Date 1 Rittal IT Solutions The State of the Data Center Market

More information

University of Melbourne Symposium on ICT Sustainability Dan Pointon 25 November 2008

University of Melbourne Symposium on ICT Sustainability Dan Pointon 25 November 2008 University of Melbourne Symposium on ICT Sustainability Dan Pointon 25 November 2008 Contents Welcome and Introduction Chapter 1: Data centre energy recap Chapter 2: Co-generation Chapter 3: CTC case study

More information

So you want to build a data centre? Look what s coming from BICSI! Matt Flowerday Capitoline FZC mflowerday@capitoline.org

So you want to build a data centre? Look what s coming from BICSI! Matt Flowerday Capitoline FZC mflowerday@capitoline.org So you want to build a data centre? Look what s coming from BICSI! Matt Flowerday Capitoline FZC mflowerday@capitoline.org So you want to build a data centre? Who do you contact? How do you work out what

More information

Presented at Computing in High Energy & Nuclear Physics

Presented at Computing in High Energy & Nuclear Physics Presented at Computing in High Energy & Nuclear Physics CHEP - Prague, Czech Republic March 25, 2009 Dean Nelson Sr. Director, Global Lab & Datacenter Design Services (GDS) 1 Density is King - Moore s

More information

esign FAQ 1. What is the online esign Electronic Signature Service? 2. Where the esign Online Electronic Signature Service can be used?

esign FAQ 1. What is the online esign Electronic Signature Service? 2. Where the esign Online Electronic Signature Service can be used? esign FAQ 1. What is the online esign Electronic Signature Service? esign Electronic Signature Service is an innovative initiative for allowing easy, efficient, and secure signing of electronic documents

More information

National Grid Your Partner in Energy Solutions

National Grid Your Partner in Energy Solutions National Grid Your Partner in Energy Solutions National Grid Webinar: Enhancing Reliability, Capacity and Capital Expenditure through Data Center Efficiency April 8, 2014 Presented by: Fran Boucher National

More information

How to build your Data Center Digitice roadshow Vaasa 3.12.2015

How to build your Data Center Digitice roadshow Vaasa 3.12.2015 How to build your Data Center Digitice roadshow Vaasa 3.12.2015 Mikko Aho Sales Director 044 593 4698 1 A Strong Family The Friedhelm Loh Group a successful business 11.500 employees worldwide 78 int.

More information

Why Data Center Design and Innovation Matters

Why Data Center Design and Innovation Matters Why Data Center Design and Innovation Matters Michael Ponke Principal, DCE Practice Professional Services October 07, 2009 Agenda The Eco Challenge Data Center revolution Why Data Center Design and Innovation

More information

Elements of Energy Efficiency in Data Centre Cooling Architecture

Elements of Energy Efficiency in Data Centre Cooling Architecture Elements of Energy Efficiency in Data Centre Cooling Architecture Energy Efficient Data Center Cooling 1 STULZ Group of Companies Turnover 2006 Plastics Technology 400 Mio A/C Technology 200 Mio Total

More information

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Intel Intelligent Power Management Intel How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Power and cooling savings through the use of Intel

More information

Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers

Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers Prepared for the U.S. Department of Energy s Federal Energy Management Program Prepared By Lawrence Berkeley National

More information

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions Free Cooling in Data Centers John Speck, RCDD, DCDC JFC Solutions Why this topic Many data center projects or retrofits do not have a comprehensive analyses of systems power consumption completed in the

More information

Safeguard your critical IT assets in a highly secure, fully redundant, environmentally-conditioned and constantly monitored hosting space to receive

Safeguard your critical IT assets in a highly secure, fully redundant, environmentally-conditioned and constantly monitored hosting space to receive Co-Location Services Safeguard your critical IT assets in a highly secure, fully redundant, environmentally-conditioned and constantly monitored hosting space to receive optimum performance 24x7. SERVICE

More information

Dedicated Hosting Services

Dedicated Hosting Services Dedicated Hosting Services Protect and manage your Servers/ Routers/ Switches/ storage devices/ security devices under a highly secure hosting space and get the finest performances out of them. SERVICE

More information

Data Center Technology: Physical Infrastructure

Data Center Technology: Physical Infrastructure Data Center Technology: Physical Infrastructure IT Trends Affecting New Technologies and Energy Efficiency Imperatives in the Data Center Hisham Elzahhar Regional Enterprise & System Manager, Schneider

More information

High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc.

High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc. High Density Data Centers Fraught with Peril Richard A. Greco, Principal EYP Mission Critical Facilities, Inc. Microprocessors Trends Reprinted with the permission of The Uptime Institute from a white

More information

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: www.cruptime.com Uptime Racks: www.uptimeracks.com

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: www.cruptime.com Uptime Racks: www.uptimeracks.com Cooling Small Server Rooms Can Be Inexpensive, Efficient and Easy - Jim Magallanes Computer Room Uptime: www.cruptime.com Uptime Racks: www.uptimeracks.com Server Rooms Description & Heat Problem Trends

More information

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia Prepared for the U.S. Department of Energy s Federal Energy Management Program

More information

Case Study: Guaranteed efficiency through standardised data centres

Case Study: Guaranteed efficiency through standardised data centres Case Study: Guaranteed efficiency through standardised data centres Rittal / SEC Event / October 2014 1 Case Study: Guaranteed efficiency through standardised data centres Smart Energy Community Event

More information

Questions to be responded to by the firm submitting the application. Why do you think this project should receive an award? How does it demonstrate:

Questions to be responded to by the firm submitting the application. Why do you think this project should receive an award? How does it demonstrate: Questions to be responded to by the firm submitting the application Why do you think this project should receive an award? How does it demonstrate: innovation, quality, and professional excellence transparency

More information

Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre

Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre S. Luong 1*, K. Liu 2, James Robey 3 1 Technologies for Sustainable Built Environments, University of Reading,

More information

Greening Commercial Data Centres

Greening Commercial Data Centres Greening Commercial Data Centres Fresh air cooling giving a PUE of 1.2 in a colocation environment Greater efficiency and greater resilience Adjustable Overhead Supply allows variation in rack cooling

More information

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert Data Center Consolidation Trends & Solutions Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert Agenda Traditional Data Centers Drivers of a Changing Environment Alternate

More information

How to Build a Data Centre Cooling Budget. Ian Cathcart

How to Build a Data Centre Cooling Budget. Ian Cathcart How to Build a Data Centre Cooling Budget Ian Cathcart Chatsworth Products Topics We ll Cover Availability objectives Space and Load planning Equipment and design options Using CFD to evaluate options

More information

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers Energy Efficiency Opportunities in Federal High Performance Computing Data Centers Prepared for the U.S. Department of Energy Federal Energy Management Program By Lawrence Berkeley National Laboratory

More information

Future-Proof the Banking and Finance Data Center

Future-Proof the Banking and Finance Data Center Future-Proof the Banking and Finance Data Center Reinier Dungca Rey Perea Marketing Manager, Southeast Asia and North Asia Manager, Local Technical Support Emerson Network Power Emerson Network Power Philippines

More information

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres What factors determine the energy efficiency of a data centre? Where is the energy used? Local Climate Data Hall Temperatures Chiller / DX Energy Condenser / Dry Cooler / Cooling Tower Energy Pump Energy

More information

About Injazat. Enterprise Cloud Services. Premier Data Center. IT Outsourcing. Learning and Development Services. Enterprise Application Services

About Injazat. Enterprise Cloud Services. Premier Data Center. IT Outsourcing. Learning and Development Services. Enterprise Application Services About Injazat Injazat Data Systems is an industry-recognized market leader in the region for Information Technology Outsourcing, Cloud and Data Center Managed Services delivered from the region s 1st Tier

More information

South Asia s First Uptime Institute Certified TIER- IV IDC in Mumbai delivering 99.999% uptime

South Asia s First Uptime Institute Certified TIER- IV IDC in Mumbai delivering 99.999% uptime South Asia s First Uptime Institute Certified TIER- IV IDC in Mumbai delivering 99.999% uptime GPX India Pvt Ltd The Leader In Carrier Neutral TIER IV IDC s In Emerging Markets Incorporated in August 2002,

More information

The Use of Fresh Air in the Data Centre

The Use of Fresh Air in the Data Centre The Use of Fresh Air in the Data Centre White paper of a round table debate by industry experts on this key topic. Hosted by Keysource with participants including the Uptime Institute. Sophistication Through

More information

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings WHITE PAPER Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings By Lars Strong, P.E., Upsite Technologies, Inc. Kenneth G. Brill, Upsite Technologies, Inc. 505.798.0200

More information

DATACENTER COLOCATION. Flexible, Secure and Connected

DATACENTER COLOCATION. Flexible, Secure and Connected DATACENTER COLOCATION Flexible, Secure and Connected Flexible Solutions for Your Requirements Contents Your Goals 2 Compound and Buildings 4 Security 6 Infrastructure 8 Free Choice 10 Good Reasons 12 Our

More information

Convergence of Complexity

Convergence of Complexity Convergence of Complexity Optimize Existing Data Center Space Measure And Allocate Energy Cost Plan for new data centers or additional capacity How to make your Data Center Last Longer, Gartner, December

More information

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

Reference Guide: SmartDesign Approach: Common Data Center Challenges: Smart Solutions Reference Guide Solutions For Business-Critical Continuity 1100kW Tier 3 With High Density Design Intelligent, Integrated Infrastructure for the Data Center Reference Guide: 1100kW Tier

More information

Data Center Components Overview

Data Center Components Overview Data Center Components Overview Power Power Outside Transformer Takes grid power and transforms it from 113KV to 480V Utility (grid) power Supply of high voltage power to the Data Center Electrical Room

More information

Location. Central Business District. Ataturk Airport IFC. Sabiha Gökçen Airport

Location. Central Business District. Ataturk Airport IFC. Sabiha Gökçen Airport Welcome Zenium Istanbul One provides 12,000 square metres of high specification technical space across three purpose-built data centers. It is Turkey s first wholesale data center offering; the data halls

More information

HPPR Data Center Improvements Projects Towards Energy Efficiency (CFD Analysis, Monitoring, etc.)

HPPR Data Center Improvements Projects Towards Energy Efficiency (CFD Analysis, Monitoring, etc.) HPPR Data Center Improvements Projects Towards Energy Efficiency (CFD Analysis, Monitoring, etc.) Felipe Visbal / March 27, 2013 HPPR Data Center Technologies Team Services Data Centers: Thermal Assessments

More information

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while

More information

Datacentre Studley. Dedicated managed environment for mission critical services. Six Degrees Group www.6dg.co.uk

Datacentre Studley. Dedicated managed environment for mission critical services. Six Degrees Group www.6dg.co.uk Dedicated managed environment for mission critical services www.6dg.co.uk Our datacentres are the core of our business. At we own and manage 30,000 square feet of highly available, geographically diverse

More information

Data Centers: How Does It Affect My Building s Energy Use and What Can I Do?

Data Centers: How Does It Affect My Building s Energy Use and What Can I Do? Data Centers: How Does It Affect My Building s Energy Use and What Can I Do? 1 Thank you for attending today s session! Please let us know your name and/or location when you sign in We ask everyone to

More information

Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie

Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie Mukesh Khattar, Energy Director, Oracle National Energy Efficiency Technology Summit, Sep. 26, 2012, Portland, OR Agenda

More information

DATA CENTRE DESIGN AND

DATA CENTRE DESIGN AND SPUSC 2008 SOUTH PACIFIC USER SERVICES CONFERENCE DATA CENTRE DESIGN AND ENERGY INITIATIVES Presented by Jarrad Clift Electrical Engineer Greenstar Accredited Presentation Content Data Centres General

More information

Registrar On-Boarding Process

Registrar On-Boarding Process UIDAI Unique Identification Authority of India Planning Commission, Govt. of India (GoI), 3rd Floor, Tower II, Jeevan Bharati Building, Connaught Circus, New Delhi 110001 Registrar On-Boarding Process

More information

CANNON T4 MODULAR DATA CENTRE HALLS

CANNON T4 MODULAR DATA CENTRE HALLS CANNON T4 MODULAR DATA CENTRE HALLS Halve up-front investment, use a Modular fit out approach Highly efficient, Low PUE, Scalable system with reduced Capex and Opex Turnkey solutions available complete,

More information

Global Data Center & Colocation Facilities

Global Data Center & Colocation Facilities Global Data Center & Colocation Facilities Managed Hosting & Storage Services Managed Servers Virtualization services Database Management Managed Storage and Back up Services Managed Load Balancing SaaS/IaaS

More information

Datacenter Efficiency

Datacenter Efficiency EXECUTIVE STRATEGY BRIEF Operating highly-efficient datacenters is imperative as more consumers and companies move to a cloud computing environment. With high energy costs and pressure to reduce carbon

More information

Electrical Systems. <Presenter>

Electrical Systems. <Presenter> Review Root Causes of Energy Inefficiency Roadmap to Maximize Energy Efficiency Best Practices Alternative Energy Sources Controls Take Aways Seek Professional Help. ENERGY INEFFICIENCY OF

More information

Solutions to Make Your Data Center Energy Effi cient

Solutions to Make Your Data Center Energy Effi cient Common $en e: Solutions to Make Your Data Center Energy Effi cient Energy effi ciency is a life style. It s also common sense. In a data center, the name of the game is effi ciency and how many compute

More information

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Intel Intelligent Power Management Intel How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Power savings through the use of Intel s intelligent

More information

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

Energy Efficiency Best Practice Guide Data Centre and IT Facilities 2 Energy Efficiency Best Practice Guide Data Centre and IT Facilities Best Practice Guide Pumping Systems Contents Medium-sized data centres energy efficiency 3 1 Introduction 4 2 The business benefits

More information

Server room guide helps energy managers reduce server consumption

Server room guide helps energy managers reduce server consumption Server room guide helps energy managers reduce server consumption Jan Viegand Viegand Maagøe Nr. Farimagsgade 37 1364 Copenhagen K Denmark jv@viegandmaagoe.dk Keywords servers, guidelines, server rooms,

More information

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management. AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled

More information

How High Temperature Data Centers and Intel Technologies Decrease Operating Costs

How High Temperature Data Centers and Intel Technologies Decrease Operating Costs Intel Intelligent Management How High Temperature Data Centers and Intel Technologies Decrease Operating Costs and cooling savings through the use of Intel s Platforms and Intelligent Management features

More information