This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits.
|
|
- Shannon Baldwin
- 8 years ago
- Views:
Transcription
1 This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits. DCD, DCOM, DCE DESIGN IMPLEMENTATION BEST PRACTICE OPERATION & MANAGEMENT DATA CENTRE DESIGN AND
2 Data Centre Design LESSON PLAN Leaning Outcomes Understand the method of translating an IT requirement e.g. number of racks and servers etc., into a data centre space and size plan Understand how to size an air conditioning system in an N or N+1 format Understand how to size a data centre UPS, generator and power supply in an N, N+1 and 2N format Understand that the basics of successful data centre design require correct location, air conditioning, power and cable interconnection planning and a focus on energy efficiency and resilience. Assessment criteria Demonstrate an ability to take a list of customer requirements and a list of IT equipment by planning and sizing the spaces of a data centre example project Size an example project when given inputs of IT load, UPS heat, lighting and solar gain Size an example project when given inputs of IT load, resilience model and customer expansion plans Obtain a mark of at least 60% in the multiple choice test of 40 questions DAY 1 Introduction Day Data Centre spaces Day Raised access floors Day What is a Data Centre? Limiting factors on design Technical Standards What will it cost? Tiers and Classes for reliability Data Centre Efficiency PUE Ideal locations Engineered spaces needed for a data centre Architectural requirements Sizing the computer room from an IT requirement Calculating floor strength Room heights Access and DDA requirements Fire escapes and emergency lighting Other facilities management issues Calculating floor strength Distributed and point loads Standards Correct sealing Calculating floor heights Zinc whisker contamination Exercise 1 Biochem plc location Issues Exercise 2 Biochem plc space planning exercise Racks and location Day Hot and cold aisle concept 7 and 8 tile pitch models Server and communications racks 2 and 4 post designs Bad layout examples Exercise 3 Biochem plc optimal rack layout in computer room DATA CENTRE DESIGN AND
3 Data Centre Design DAY 2 Cooling IT equipment Day Air conditioning and cooling principles Laws of thermodynamics Precision v comfort cooling Available technologies DX v central chiller options Dry cooler ASHRAE, TIA and CIBSE requirements Low humidity problems Ventilation and filtration requirements New TUI Tier definitions of cooling Energy saving techniques e.g. dry cooler, air economiser, water economiser Solar thermal gain How to calculate heat loads and aircon sizing kw v tons v BTU of cooling How much heat comes from IT equipment Hot aisle/cold aisle options Enclosed cold and hot aisles Other rack cooling options Side to side cooling for large Cisco switches Water cooled racks CO2 cooled racks Spot cooling Air flow calculations TUI Tiering requirements CFD analysis Class exercise Calculate cooling requirement of a typical computer room and plan N+1 cooling model Power Day IT grade earthing and bonding Day BICSI and TIA N, N+1 and 2N power models EU Code of Conduct requirements AC v DC Power, kw and kva Power factor issues Single v 3 phase distribution Tier 1-4 models How to calculate power requirements, UPS and generator sizing UPS options: Off-line, on line dual conversion, delta, transformerless, Battery and kinetic energy systems Emergency Power Off requirements Power Distribution units European, USA and world standards EN and TIA 607 Grounding bars Equipotential bonding Signal reference grids Class Exercise Calculate power requirements of a typical computer, size UPS and generators and plan an N+1 UPS model Exercise 4 Biochem plc. Calculate number of racks and power requirements from a list of IT equipment DATA CENTRE DESIGN AND
4 Data Centre Design DAY 3 Cable containment Separation of power and data cables to EU and USA standards Calculating fill factors Cable containment options Affect of different cable sizes Fire stopping Fire Low risk fire cabling Fire safety plans Fire detection methods Aspirating smoke detection (VESDA) Integrating fire, BMS, HVAC and power systems Fire suppression techniques Inert gas v halocarbon techniques Water mist and low oxygen (hypoxic) methods Price comparisons American plenum, riser and general purpose cables European low smoke zero halogen cables Relative costs Structured cabling intro Selecting cable components Separation of power and data cables to EU and USA standards Calculating fill factors Cable containment options Affect of different cable sizes Fire stopping Latest requirements of 10GBASE-T Defining screened and unscreened (shielded and unshielded) cables Cable sizes Copper connectors and patch panels Optical connectors and components Preterminated cabling solutions DATA CENTRE DESIGN AND
5 Data Centre Design DAY 3 Optical cable systems Matching LANs to cables Defining optical fibres e.g. OM!, OM3 etc Latest OM4 and OS2 fibres Advantages of optical fibre Value engineering cable and LAN plant Cable systems , 3 and 4 connector systems The ISO hierarchical model Intelligent patching options Tier 1-4 requirements Different cabling models e.g. zone cabling, centralised cabling Best generic designs US v EU standards and terminology Security and BMS Integrating systems with BMS Facilities management systems IP v industrial protocols CCTV methods Access control Room, rack or site monitoring Tier 1-4 requirements Business continuity Business continuity and disaster recovery Why data centres fail Process and operational management Final exam DATA CENTRE DESIGN AND
6 Data Centre Operations Management LESSON PLAN Leaning Outcomes Understand the importance of energy efficiency in data centres, how to measure it and how to improve it. Understand the basic of capacity management in a data centre and make simple calculations Understand how poor layout and procedures lead to serious business continuity issues in a data centre Understand the basics of successful data centre operational management including the documentation which should be in place and the policies and procedures to operate. Assessment criteria Demonstrate through exercise an ability to calculate DCiE and PUE and identify how these efficiency figures can be improved upon. Calculate some examples of power and cooling capacity and identify adequacy. Analyse some examples of bad practice and identify how improvements can be made to reduce risk and increase energy efficiency. Obtain a mark of at least 60% in the multiple choice test of 40 questions DAY 4 Introduction SAVING ENERGY Understanding the green agenda and metrics Building Management Systems and monitoring Improving rack and floor layout Improving Power Efficiency Understanding the power flow Capacity Management Introduction to the subject Why do data centres fail? A review of published data centre failure tables and Capitoline's own analysis of failure modes PUE and DCiE The Green Grid Energy Star LEED/BREEAM schemes US Environmental Protection Agency EU Code of Conduct & Best Practice TUI and CADE Power and CO2 relationships What is a BMS? What should be monitored and when EU Code of conduct requirements Bringing it all together with a Control Room Ideal rack layouts and hot aisle/cold aisle models Optimising equipment layout within a rack Cabling: how not to make a mess Correcting layout to improve energy efficiency Amps, volts, kw, kva and power factor What is 3 Phase? Balancing your phases! How to make energy savings in the power system. Why does power factor matter? The energy train from mains input to the rack, in block diagram form Essential block diagram items e.g. generators, UPS, batteries, PDU etc N, N+1 and 2N models Typical power problems and how to avoid them Understanding Capacity Management How does poor capacity management effect resilience? What can happen if you get it wrong? Exercise 1 Calculate DCiE, PUE and UPS efficiency? What is the Tier rating? Exercise 2 What's wrong? Faults in real examples? Exercise 3 Is this 3 phase load balanced? Exercise 4 How long until my room overheats?
7 Data Centre Operations Management DAY 5 Correct operational procedures and documentation Security requirements IT technical policies Asset register Visitor and security policy Building operational settings Critical alarms and settings Maintenance plans Incident management Call list Permit to work Site H&S manual Change control and work orders Fire safety plans, detection and alarms Staff and contractor proof of competence Disaster recovery plan Housekeeping Responsibilities in the Data Centre Labelling & Signs MEETING THE PHYSICAL REQUIREMENTS OF EXTERNAL AUDIT STANDARDS TIA 942 security definitions British Government Policy framework BICSI 002 standard Payment Card Industry security standard Access control CCTV Visitor and security policy Data Centre Audits How do you manage external audits internally? What do we audit against? What do you want to achieve through audit? PLANNING FOR DISASTER RECOVERY AND OTHER CHANGES Exercise 5 Analysing the results of an audit? Business Continuity and Disaster Recovery External & Internal Risks ISO series BS25777 NFPA 1600 Combining good design and procedures to ensure business continuity Defining DR requirements Defining a DR plan and rehearsing it Communicating with customers and stakeholders Sizing the DR facility Consolidation & moves/upgrades Why consolidate? What are the benefits? What are the problems? What to consider Final exam and feedback Final exam
8 DESIGN IMPLEMENTATION BEST PRACTICE OPERATION & MANAGEMENT DATA CENTRE DESIGN AND , w w w. k i t t e c h n o l o g i e s. c o m
So you want to build a data centre? Look what s coming from BICSI! Matt Flowerday Capitoline FZC mflowerday@capitoline.org
So you want to build a data centre? Look what s coming from BICSI! Matt Flowerday Capitoline FZC mflowerday@capitoline.org So you want to build a data centre? Who do you contact? How do you work out what
More informationData Centre Stockholm II, Sweden Flexible, advanced and efficient by design.
Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design. Equinix Telecity Kvastvägen 25-29 128 62 Sköndal Stockholm Sweden Tel: +46 (0) 8 799 3800 se.info@telecity.com www.telecitygroup.se
More informationTitle: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria
Tier 3+ 1 Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria Abstract: Schoolcraft College is constructing a High Availability (HA) Data Center
More informationTechnical specifications. Containerized data centre NTR CDC 40f+
Technical specifications Containerized data centre NTR CDC 40f+ CONTENT 1 THE PURPOSE OF CDC... 3 2 BASIC PROPERTIES... 4 2.1 EXTERNAL DIMENSIONS... 4 2.2 INSTALLATION REQIREMENTS... 4 2.3 ELECTRICAL CONNECTION
More informationBuilding a data center. C R Srinivasan Tata Communications
Building a data center C R Srinivasan Tata Communications Introduction Data Center as defined by TIA 942 A building or a portion of a building whose primary function is to house a computer room and its
More informationSpecialty Environment Design Mission Critical Facilities
Brian M. Medina PE Associate Brett M. Griffin PE, LEED AP Vice President Environmental Systems Design, Inc. Mission Critical Facilities Specialty Environment Design Mission Critical Facilities March 25,
More informationBCS Foundation Certificate in Data Centre Infrastructure Syllabus. Version 1.2 March 2015
BCS Foundation Certificate in Data Centre Infrastructure Syllabus Version 1.2 March 2015 Change History Any changes made to the syllabus shall be clearly documented with a change history log. This shall
More informationPOD S in Data Centres. The Frame Group Pty Ltd
Presented by: Greg Goode The Frame Group Pty Ltd DATA Centres? POD SOLUTIONS REFERRED TO AS: Cells Modular Rooms High Density Zones Portable Modular Data Centres (Containers) Multiple Interpretations Varied
More informationICT and the Green Data Centre
ICT and the Green Data Centre Scott McConnell Sales Manager c/o Tanya Duncan MD Interxion Ireland Green Data Centres Our Responsibility Data centre greenhouse gas emissions are projected to quadruple by
More informationRe Engineering to a "Green" Data Center, with Measurable ROI
Re Engineering to a "Green" Data Center, with Measurable ROI Alan Mamane CEO and Founder Agenda Data Center Energy Trends Benchmarking Efficiency Systematic Approach to Improve Energy Efficiency Best Practices
More informationAbout Injazat. Enterprise Cloud Services. Premier Data Center. IT Outsourcing. Learning and Development Services. Enterprise Application Services
About Injazat Injazat Data Systems is an industry-recognized market leader in the region for Information Technology Outsourcing, Cloud and Data Center Managed Services delivered from the region s 1st Tier
More informationOur data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.
AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled
More informationCapgemini UK Infrastructure Outsourcing
Together. Free your energies Capgemini UK Infrastructure Outsourcing Project Arthur Improved Data Centre Efficiency Paul Feeney Capgemini Tony Mills Spie Matthew Hall Project Arthur The Toltec data centre,
More informationEXAMPLE OF A DATA CENTRE BUILD
EXAMPLE OF A DATA CENTRE BUILD BT Harmondsworth Data Centre Hall 2 Upgrade Temperature Control have been involved in providing specialist to data centres for over 20 years, starting from providing specialist
More informationOptimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009
Optimum Climate Control For Datacenter - Case Study T. Prabu March 17 th 2009 Agenda 2 About EDEC (Emerson) Facility Data Center Details Design Considerations & Challenges Layout Design CFD Analysis Of
More informationOur data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.
AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled
More informationOur data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.
AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled
More informationSite Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME
Site Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME 2 AGENDA SESSION -1 What is Data Center? SESSION -2 Equipment and Components SESSION -3 Standard in designing Data Center
More informationTIA-942 Data Centre Standards Overview WHITE PAPER
TIA-942 Data Centre Standards Overview WHITE PAPER TIA-942 Data Centre Standards Overview For the past 20 years, cabling standards have been the cornerstone of ensuring proper design, installation, and
More informationCANNON T4 MODULAR DATA CENTRE HALLS
CANNON T4 MODULAR DATA CENTRE HALLS Halve up-front investment, use a Modular fit out approach Highly efficient, Low PUE, Scalable system with reduced Capex and Opex Turnkey solutions available complete,
More informationIMPROVING DATA CENTER EFFICIENCY AND CAPACITY WITH AISLE CONTAINMENT
DATA CENTER RESOURCES WHITE PAPER IMPROVING DATA CENTER EFFICIENCY AND CAPACITY WITH AISLE CONTAINMENT BY: STEVE HAMBRUCH EXECUTIVE SUMMARY Data centers have experienced explosive growth in the last decade.
More informationFEAR Model - Review Cell Module Block
F.E.A.R. Returns: 5 Steps Toward Data Center Efficiency Today Objectives Benefits for ITS professionals Brief review of the FEAR data center Define data center efficiency Link efficiency to the FEAR data
More informationBharat Heavy Electricals Limited Corporate Information Technology, Noida
Bharat Heavy Electricals Limited Corporate Information Technology, Noida EoI Ref. No: AA:CIT:DC/EoI Dated: 14.10.2009 Expression of Interest for Hiring of a Consultant for the Design of Data Centre 1.
More informationUniversity of St Andrews. Energy Efficient Data Centre Cooling
Energy Efficient Data Centre Cooling St. Andrews and Elsewhere Richard Lumb Consultant Engineer Future-Tech Energy Efficient Data Centre Cooling There is no one single best cooling solution for all Data
More informationDealing with Thermal Issues in Data Center Universal Aisle Containment
Dealing with Thermal Issues in Data Center Universal Aisle Containment Daniele Tordin BICSI RCDD Technical System Engineer - Panduit Europe Daniele.Tordin@Panduit.com AGENDA Business Drivers Challenges
More informationCDCDP TM Certified Data Centre Design Professional TM Qualification
PLEASE CIRCULATE to your friends, colleagues and contacts. www.hkceedu.org www.cnet-training.co.uk A Road to Certified Professional Engineer for Data Centre Design - CDCDP TM Certified Data Centre Design
More informationCase Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers
Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers Prepared for the U.S. Department of Energy s Federal Energy Management Program Prepared By Lawrence Berkeley National
More informationGreening Commercial Data Centres
Greening Commercial Data Centres Fresh air cooling giving a PUE of 1.2 in a colocation environment Greater efficiency and greater resilience Adjustable Overhead Supply allows variation in rack cooling
More informationData Centre Basiglio, Milan Flexible, advanced and efficient by design.
Data Centre Basiglio, Milan Flexible, advanced and efficient by design. TelecityGroup Via Francesco Sforza 13 Milano 3 City 20080 Basiglio MI Italy Tel: +39 02 36679500 it.info@telecity.com www.telecitygroup.it
More informationDATA CENTRE DATA CENTRE MAY 2015
DATA CENTRE DATA CENTRE MAY 2015 CONCERTHOUSE MUSIC Concerthouse Music Data Centre services are located in the Equinix Internet Business Exchange (IBX ) Centre at Mascot. This IBX offers the highest level
More informationData Center Designs and Hospital Operations
Data Center Designs and Hospital Operations Designing for Data Center Availability and the Effect on Daily Operations Joe Harris, PE, RCDD Senior Engineer, AECOM Data Centers and Hospitals June 10, 2015
More informationSovereign. The made to measure data centre
Sovereign D ATA C O N N E C T The made to measure data centre Prime Location Within touching distance of everything that s important. 2 Your Customer-Centric Data Centre For the vast majority of organisations
More informationDATA CENTER ASSESSMENT SERVICES
DATA CENTER ASSESSMENT SERVICES ig2 Group Inc. is a Data Center Science Company which provides solutions that can help organizations automatically optimize their Data Center performance, from assets to
More informationGreen Data Centre Design
Green Data Centre Design A Holistic Approach Stantec Consulting Ltd. Aleks Milojkovic, P.Eng., RCDD, LEED AP Tommy Chiu, EIT, RCDD, LEED AP STANDARDS ENERGY EQUIPMENT MATERIALS EXAMPLES CONCLUSION STANDARDS
More informationOnsite Support: 24/7/365 onsite team. Security: 24/7/365 onsite manned security and CCTV. Monitoring: 24/7/365 Environmental monitoring and management
Zen DC1 Our Services: Colocation Cloud Solutions Managed Hosting Dedicated Servers Zen DC1 - Key Facts Size: 10,000 sq ft Capacity: 150 rack capacity Ownership: 100% independently owned, operated and managed
More informationData Center Technology: Physical Infrastructure
Data Center Technology: Physical Infrastructure IT Trends Affecting New Technologies and Energy Efficiency Imperatives in the Data Center Hisham Elzahhar Regional Enterprise & System Manager, Schneider
More informationData Center Standards Making Progress on Many Fronts. Jonathan Jew J&M Consultants, Inc jew@j-and-m.com
Data Center Standards Making Progress on Many Fronts Jonathan Jew J&M Consultants, Inc jew@j-and-m.com J&M Consultants - 2008 Speaker Jonathan Jew Co-chair TIA TR-42.1.1 Data Center working group ANSI/TIA-942
More informationANSI/TIA-942 Telecommunications Infrastructure Standards for Data Centers
ANSI/TIA-942 Telecommunications Infrastructure Standards for Data Centers Jonathan Jew jew@j-and and-m.com J&M Consultants, Inc Co-chair TIA TR-42.1.1 data center committee Co-chair BICSI data centers
More informationZone B: comprises of NOC room, reception area, Help Desk area, Call Centre, Testing/Monitoring room. This zone requires approximately 1500 sq. feet.
Annexure 1 Best practices and Guidelines to Physical Security of the State Data Centre The Data Centre should ideally be built in a central location within the building complex. An approximate area of
More informationDatacentre Studley. Dedicated managed environment for mission critical services. Six Degrees Group www.6dg.co.uk
Dedicated managed environment for mission critical services www.6dg.co.uk Our datacentres are the core of our business. At we own and manage 30,000 square feet of highly available, geographically diverse
More informationMeasuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint
Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint Energy usage in the data center Electricity Transformer/ UPS Air 10% Movement 12% Cooling 25% Lighting, etc. 3% IT Equipment
More informationData Center Cabling Design Trends
Data Center Cabling Design Trends BICSI Regional Meeting Maurice Zetena Fiber Connect Infrastructure Trends Infrastructure Trends Any to All Trunk Cabling Trends: Data Center Infrastructure Media Choice:
More informationJAWAHARLAL NEHRU UNIVERSITY
School of Biotechnology JAWAHARLAL NEHRU UNIVERSITY New Delhi 110 067 Tender No. JNU/SBT/DBT-BUILDER/Data Centre/2015-16 Sealed Quotation for the establishment of a Data Centre for High-End Computational
More informationBELLE VUE MANCHESTER DATA CENTRE
www.iracknet.com 0843 557 5712 bellevue@iracknet.com www.iracknet.com BELLE VUE MANCHESTER DATA CENTRE 02 BELLE VUE MANCHESTER HIGHLY ADVANCED DATA CENTRE PURPOSE BUILT TO DELIVER UNRIVALLED FLEXIBILITY
More informationData Centers: Definitions, Concepts and Concerns
Data Centers: Definitions, Concepts and Concerns Arash Mousavi DCC September 2013 Agenda 1. Introduction 2. Issues in Modern Data Centers: Siemens Integrated Data Center Solutions 3. Issues in Modern Data
More informationAuditing a Data Centre But to What Standard?
Auditing a Data Centre But to What Standard? Barry Elliott, RCDD Capitoline LLP belliott@capitoline.co.uk www.capitoline.eu Data Centre Auditing Capitoline has audited over 30 data centres in the UK, Ireland,
More informationHPPR Data Center Improvements Projects Towards Energy Efficiency (CFD Analysis, Monitoring, etc.)
HPPR Data Center Improvements Projects Towards Energy Efficiency (CFD Analysis, Monitoring, etc.) Felipe Visbal / March 27, 2013 HPPR Data Center Technologies Team Services Data Centers: Thermal Assessments
More informationIntroduction to Data Centres
Introduction to Data Centres Grant Sauls CCDA CDNIDS CDCSNDS CDCD DCCA JNCIA ER JNCIS E Project+ DCE CCTT (FIA) CDS Certified Data Center Design Specialist AGENDA 9am 5pm What and why we have Data Centre
More informationData Centers: How Does It Affect My Building s Energy Use and What Can I Do?
Data Centers: How Does It Affect My Building s Energy Use and What Can I Do? 1 Thank you for attending today s session! Please let us know your name and/or location when you sign in We ask everyone to
More informationData Centre Issues supported in TIA-942 : "Telecommunications Infrastructure for Data Centre s"
Data Centre Issues supported in TIA-942 : "Telecommunications Infrastructure for Data Centre s" Data centre Standard EN50173-5 : "Telecommunications Infrastructure for Data Centre s Due, 2006 Gary Highton,
More informationA data centre Standard for the Amsterdam Internet Exchange
A data centre Standard for the Amsterdam Internet Exchange A Standard defining the minimum acceptable, and also the desirable levels, of technical implementation, resilience of operation and business continuity
More informationEuropean Code of Conduct for Data Centre. Presentation of the Awards 2014
European Code of Conduct for Data Centre Presentation of the Awards 2014 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport 1 The Code of Conduct for Data Centre Results European
More informationUpgrading the PRS datacentres: space requirement. S. S. Mathur, GM-IT, CRIS
Upgrading the PRS datacentres: space requirement S. S. Mathur, GM-IT, CRIS PRS / UTS scenario: then and now Year 2000 PRS: 600 locations UTS: 0 locations Year 2008 PRS 1600 locations E-ticketing Passengers
More informationIBM Twin Data Center Complex Ehningen Peter John IBM BS peter.john@de.ibm.com. 2011 IBM Corporation
IBM Twin Data Center Complex Ehningen Peter John IBM BS peter.john@de.ibm.com Overview Profile IBM owned facility 6447 m² IT-Space Infrastructure concurrent maintainable (Tier Level 3) Feed-ins of Power
More informationAEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY
AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY The Aegis Services Power and Assessment Service provides an assessment and analysis of your data center facility and critical physical
More informationServer Room Thermal Assessment
PREPARED FOR CUSTOMER Server Room Thermal Assessment Analysis of Server Room COMMERCIAL IN CONFIDENCE MAY 2011 Contents 1 Document Information... 3 2 Executive Summary... 4 2.1 Recommendation Summary...
More informationData Centre Testing and Commissioning
Data Centre Testing and Commissioning What is Testing and Commissioning? Commissioning provides a systematic and rigorous set of tests tailored to suit the specific design. It is a process designed to
More informationAuditing a data centre but to what standard?
Auditing a data centre but to what standard? Matt Flowerday RCDD Capitoline LLP mflowerday@capitoline.co.uk www.capitoline.me Data centre auditing Capitoline has audited over 30 data centres in the UK,
More informationEnergy Efficiency Best Practice Guide Data Centre and IT Facilities
2 Energy Efficiency Best Practice Guide Data Centre and IT Facilities Best Practice Guide Pumping Systems Contents Medium-sized data centres energy efficiency 3 1 Introduction 4 2 The business benefits
More informationMaking Existing Server Rooms More Efficient Steve Bowes-Phipps, Data Centre Manager University of Hertfordshire. http://rare-idc.herts.ac.
Making Existing Server Rooms More Efficient Steve Bowes-Phipps, Data Centre Manager University of Hertfordshire http://rare-idc.herts.ac.uk Making Existing Server Rooms More Efficient Reduction and Re-use
More informationVISIT 2010 Fujitsu Forum Europe 0
VISIT 2010 Fujitsu Forum Europe 0 Virtualization & Automation Room 13a Shaping tomorrow with you. Green Data Center Services Martin Provoost Director, Data Centers and Networks, Fujitsu UK & Ireland 14:00
More informationIntroducing UNSW s R1 Data Centre
Introducing UNSW s R1 Data Centre R1-DC Our New High Density Data Centre Right here Right now - Welcome to our newest UNSW Data Centre R1-DC R1 Location on UNSW Randwick campus. Keeping it in the family
More informationBRUNS-PAK Presents MARK S. EVANKO, Principal
BRUNS-PAK Presents MARK S. EVANKO, Principal Data Centers of the Future and the Impact of High Density Computing on Facility Infrastructures - Trends, Air-Flow, Green/LEED, Cost, and Schedule Considerations
More informationAutomating Infrastructure A connectivity perspective for BICSI SEA meeting, November 2011
Automating Infrastructure A connectivity perspective for BICSI SEA meeting, November 2011 Opportunities in Automating Infrastructure Why Automation in Data Center? Tiers, compartments and complexity Work
More informationData Centre Best Practices Summary
Data Centre Best Practices Summary Delivering Successful Technology Rooms 1 END2END s Data Centre Best Practices END2END design Data Centres/Computer Rooms based on 7 major principles: Understanding the
More informationData Centre Capacity and Electricity Use How the EU Code of Conduct can help your data centre electricity bill
Data Centre Capacity and Electricity Use How the EU Code of Conduct can help your data centre electricity bill Chris Cartledge Independent Consultant C.Cartledge@sheffield.ac.uk Summary ICT Electricity
More informationAnalysis of data centre cooling energy efficiency
Analysis of data centre cooling energy efficiency An analysis of the distribution of energy overheads in the data centre and the relationship between economiser hours and chiller efficiency Liam Newcombe
More informationNational Aluminium Co. Ltd.
National Aluminium Co. Ltd. [NALCO] EXPRESSION OF INTEREST FOR DATA CENTRE CO-LOCATION SERVICES Address for Communication The Project Manager ERP P/1, NALCO BHAWAN NAYAPALLI, BHUBANESWAR 751061 E mail:
More informationDataCenter 2020: first results for energy-optimization at existing data centers
DataCenter : first results for energy-optimization at existing data centers July Powered by WHITE PAPER: DataCenter DataCenter : first results for energy-optimization at existing data centers Introduction
More informationDATA CENTRES UNDERSTANDING THE ISSUES TECHNICAL ARTICLE
DATA CENTRES UNDERSTANDING THE ISSUES TECHNICAL ARTICLE Molex Premise Networks EXECUTIVE SUMMARY The term data centre usually conjures up an image of a high-tech IT environment, about the size of a football
More informationAT&T Internet Data Center Site Specification - Phoenix Area (Mesa, AZ)
AT&T Internet Data Center Site Specification - Phoenix Area (Mesa, AZ) Site Biography Market Area: Phoenix, Mesa, Tempe, Chandler, Scottsdale, AZ Location: Mesa, AZ 85201 Address: 1301 University Blvd.
More informationHow To Improve Energy Efficiency In A Data Center
Google s Green Data Centers: Network POP Case Study Table of Contents Introduction... 2 Best practices: Measuring. performance, optimizing air flow,. and turning up the thermostat... 2...Best Practice
More informationDocumenting and Managing Infrastructure Connectivity
Documenting and Managing Infrastructure Connectivity David Cuthbertson Square Mile Systems Ltd david.cuthbertson@squaremilesystems.com www.squaremilesystems.com Square Mile Background Develop toolsets,
More informationEngineers Ireland Cost of Data Centre Operation/Ownership. 14 th March, 2013 Robert Bath Digital Realty
Engineers Ireland Cost of Data Centre Operation/Ownership 14 th March, 2013 Robert Bath Digital Realty Total Cost of Operation (TCO) Rental TCO - 10 Year Lease Term Power Cooling Connectivity Costs 26%
More informationOur Hosting Infrastructure. An introduction to our Platform, Data Centres and Data Security. www.in-tuition.net
Our Hosting Infrastructure An introduction to our Platform, Data Centres and Data Security www.in-tuition.net UK Infrastructure Infrastructure Overview Intuition Networks has provided managed Internet
More informationData Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore
Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore Introduction Agenda Introduction Overview of Data Centres DC Operational
More informationHeat Recovery from Data Centres Conference Designing Energy Efficient Data Centres
What factors determine the energy efficiency of a data centre? Where is the energy used? Local Climate Data Hall Temperatures Chiller / DX Energy Condenser / Dry Cooler / Cooling Tower Energy Pump Energy
More informationNetwork Router Monitoring & Management Services
Network Router Monitoring & Management Services Get different parameters of routers monitored and managed, and protect your business from planned and unplanned downtime. SERVICE DEFINITION: NETWORK ROUTER
More informationData Centre Solutions energy efficient by design
Data Centre Solutions energy efficient by design Mobile & Modular Data Centre Solutions Agile, Scalable, High Performance Mobile and Modular DC solutions Flexible, scalable high performance mobile & modular
More informationHow High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions
Intel Intelligent Power Management Intel How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Power and cooling savings through the use of Intel
More informationInterested in conducting your own webinar? Email webinars@bnpmedia.com
Interested in conducting your own webinar? Email webinars@bnpmedia.com Improving Efficiencies by Integrating Data Center Systems August 30 th, 2012 Audio Abstract Presenter Info Slides Handouts Group Chat
More informationSpecifying an IT Cabling System
Specifying an IT Cabling System This guide will help you produce a specification for an IT cabling system that meets your organisation s needs and gives you value for money. You will be able to give your
More informationLocation. Central Business District. Ataturk Airport IFC. Sabiha Gökçen Airport
Welcome Zenium Istanbul One provides 12,000 square metres of high specification technical space across three purpose-built data centers. It is Turkey s first wholesale data center offering; the data halls
More informationGUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group
GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY Public Sector ICT Special Working Group SERVER ROOM ENERGY EFFICIENCY This guide is one of a suite of documents that aims to provide guidance on ICT energy efficiency.
More informationANSI/TIA-942 Telecommunications Infrastructure Standard for Data Centers
ANSI/TIA-942 Telecommunications Infrastructure Standard for Data Centers Jonathan Jew jew@j-and-m.com J&M Consultants, Inc Co-chair TIA TR-42.1.1 data center working group Co-chair BICSI data centers standards
More informationEnergy Efficient Server Room and Data Centre Cooling. Computer Room Evaporative Cooler. EcoCooling
Energy Efficient Server Room and Data Centre Cooling Computer Room Evaporative Cooler EcoCooling EcoCooling CREC Computer Room Evaporative Cooler Reduce your cooling costs by over 90% Did you know? An
More informationStrategic Data Centre Site Profiles Data Centre Co-Location London North
Strategic Data Centre Site Profiles Data Centre Co-Location London North Document details Version: 1 Last Updated: 12/07/2013 Version 1.0 Page 1 of 6 Contents 1. LONDON NORTH...3 1.1 LOCATION...3 1.2 TECHNICAL
More informationhong kong//china data center specifications tel: +61 2 9948 8888 fax: +61 2 9948 1111 internet + intellectual property + intelligence
internet + intellectual property + intelligence We thank you for the opportunity to work with you regarding your colocation needs in Hong Kong, China. We can colocate standard rack-mountable servers or
More informationCombining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency
A White Paper from the Experts in Business-Critical Continuity TM Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency Executive Summary Energy efficiency
More informationAs close to perfection. development and production. Modular data center
As close to perfection development and production Modular data center August 2014 What is GreenMDC modular data center? Basically it is the modular design construction which is realized by the principle
More informationSecurity+ Guide to Network Security Fundamentals, Fourth Edition. Chapter 13 Business Continuity
Security+ Guide to Network Security Fundamentals, Fourth Edition Chapter 13 Business Continuity Objectives Define environmental controls Describe the components of redundancy planning List disaster recovery
More informationBCA-IDA Green Mark for Existing Data Centres Version EDC/1.0
BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0 To achieve GREEN MARK Award Pre-requisite Requirement All relevant pre-requisite requirements for the specific Green Mark Rating are to be complied
More informationProducts. Technology. Services. Delivered Globally. DATA CENTER SOLUTIONS
Products. Technology. Services. Delivered Globally. DATA CENTER SOLUTIONS THE ANIXTER DIFFERENCE Anixter has the knowledge and products to make your data center secure, productive, power efficient and
More informationBest Practices. for the EU Code of Conduct on Data Centres. Version 1.0.0 First Release Release Public
Best Practices for the EU Code of Conduct on Data Centres Version 1.0.0 First Release Release Public 1 Introduction This document is a companion to the EU Code of Conduct on Data Centres v0.9. This document
More informationData Centre Cabling. 20 August 2015 Stefan Naude RCDD The SIEMON Company
Data Centre Cabling 20 August 2015 Stefan Naude RCDD The SIEMON Company Agenda 1. Data Centre Standards 2. The Need for Speed 3. Copper in the Data Centre 4. Fibre in the Data Centre 5. Top of Rack vs
More informationStatement Of Work. Data Center Power and Cooling Assessment. Service. Professional Services. Table of Contents. 1.0 Executive Summary
Statement Of Work Professional Services Data Center Power and Cooling Assessment Data Center Power and Cooling Assessment Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features
More informationMejora la Eficiencia Operativa en Centros de Datos
Mejora la Eficiencia Operativa en Centros de Datos Marco Antonio Damián Data Center Specialist Panduit Data Center Operational Efficiency Operational Efficiency is done through: Cabinets and racks Cable
More informationDirect Fresh Air Free Cooling of Data Centres
White Paper Introduction There have been many different cooling systems deployed in Data Centres in the past to maintain an acceptable environment for the equipment and for Data Centre operatives. The
More informationThe Mission Critical Data Center Understand Complexity Improve Performance
The Mission Critical Data Center Understand Complexity Improve Performance Communications Technology Forum Fall 2013 Department / Presenter / Date 1 Rittal IT Solutions The State of the Data Center Market
More informationData Center Management. Didik Partono Rudiarto CDCP, ITIL-F, COBIT5, CITM
Data Center Management Didik Partono Rudiarto CDCP, ITIL-F, COBIT5, CITM A physical place that houses a computer network's most critical systems, including back-up power supplies, air conditioning, and
More information