PUK-Solarline. Mounting system for Photovoltaic installations
|
|
- Sherman Black
- 6 years ago
- Views:
Transcription
1 Mounting system for Photovoltaic installations
2 PUK-WERKE KG PUK-WERKE KG Kunststoff-Stahlverarbeitung GmbH & Co. PO Box Berlin Germany Headquarters and Plant Berlin Nobelstr Berlin Germany Phone: ax: Head of Sales Sales Project Management Technical Consulting Service info@puk.com Internet: Your contact person Harald Dahlmann Product manager Solar systems Phone: ax: dahlmann@puk-werke.de Plant Schönecken Industriestr Schönecken Germany (as of ) Phone: ax:
3 Legend A d D G H I y I z cross-section diameter diameter weight height axial angular impulse second class around Y-axis axial angular impulse second class around Z-axis L length k tightening zone LGL elongated hole Ø diameter P applied load t material thickness W y resisting torque around Y-axis W z resisting torque around Z-axis screwing devices, no material specified: steel, galvanized and bi-chromated hot-dip galvanized according to DIN E ISO 1461 high-grade steel, material grade number E (V 2A) high-grade steel, material grade number E / (V 4A) AL aluminium (EN AW 6063 T66) G rubber (EPDM) 1 field 2 field roof supports crossbeam diagonal longitudinal beam module carrier
4 Index PUK WERKE KG Introducing our company A Carrier systems B Module clamps C
5 Representations PUK-WERKE KG Headquarters Berlin Phone: Head of Sales Rudolf Wittmann -240 Sales / Office duty Sales District Robert Brendler -219 (Head of Department) Detlef Apel (North), 2, 3, 5, 9 Tobias Neustupny , 6, 8, 15 Jakub Plewka , 10, 11, 12, 14 Barbara Sattelberg (South), 13 Romina Menke -292 Export Ines Polenz -235 Export Rainer Sambale -224 Export Planning and Assembling Claus Arendt -229 (Head of Department) Michael Dux -215 Klaus Hahn -227 Michael Schröder -234 Eric Standfuß -216 Quotations Udo Günther -239 Angelika Rahn -232 Martin Rosenthal -231 Carsten Wollenzin -230 Underfloor systems rank Jeschke -225 (Product manager) Svenja Baer -291 Markus Schitteck -226 Solar systems Harald Dahlmann -241 (Product manager) Development and Construction Erik Vogler -140 (Head of Department) Stephan Hippel -142 Eugen Schmidt -141 Marc Zinecker -139 Quality control Marc Zinecker -139 (Quality management representative) Marketing Oliver iechtner -214 (Head of Department) Samuel R. J. Matthia -237 Stefan Zeiske -217 (as of ) Distribution warehouse: Berlin PUK-WERKE KG Nobelstr Henning Petke Phone: Mobile: ax: Nortorf PUK-WERKE KG Rudolf-Kinau-Str. 7 Michael Schimanski Phone: Mobile: ax: Nortorf PUK-WERKE KG Rudolf-Kinau-Str. 7 Michael Schimanski Phone: Mobile: ax: Hamburg Representation: Werner Wirth GmbH Hellgrundweg 111 Wolfgang Höppner Phone: ax: Braunschweig PUK-WERKE KG Schmalbachstr. 16 Detlef Gooßens Phone: Mobile: ax: Warehouse: Phone: Mobile: ax: Rudolstadt PUK-WERKE KG Caspar-Schulte-Str. 8 Hans-Joachim Müller Phone: Mobile: ax: Essen PUK-WERKE KG undlandstr. 29 Marc Winkler Phone: Mobile: ax: Köln PUK-WERKE KG Kölner Str. 265 Dieter Schmidt Phone: Mobile: ax: Groß-Umstadt PUK-WERKE KG Albert-Einstein-Str. 20 Jože Turk Phone: Mobile: ax: Glauchau PUK-WERKE KG Nikolaus-Otto-Str. 9 Holm Liebscher Phone: Mobile: ax: Vilsbiburg PUK-WERKE KG Wendelsteinstr. 11 Oliver-Wolf ranke Phone: Mobile: ax: Kornwestheim PUK-WERKE KG Albert-Einstein-Str. 2 Phone: ax: Jochen Scherer Mobile: Bernd Reiss Mobile: Kornwestheim PUK-WERKE KG Albert-Einstein-Str. 2 Phone: ax: Jochen Scherer Mobile: Daniel Di Stefano Mobile: Garching PUK-WERKE KG Robert-Bosch-Str. 11 Phone: ax: Bernhard Grefrath Mobile: Oliver-Wolf ranke Mobile: Wadgassen Representation: K&P-MEBA GmbH Zum Sitters 18 Annja Klein-Schwarz Phone: ax: Bremen Representation: A. zur Linde Industrievertretung Bürgermeister-Smidt-Str. 58 Heinz-Werner Reincke Phone: ax:
6 Representations 1 J.. KNUDTZEN A/S Billingstadsletta 97 Postboks 160 N-1378 Nesbru Phone: ax: L. MICHELS Technische Handelsonderneming B. V. Argonweg 15 NL-1362 AA Almere Stad-West Phone: ax: PUK BENELUX B.V. Lange Voren 14 P. O. Box 22 NL-5520 AA Eersel Phone: ax: J&P Building Systems Ltd. Thame orty Jane Morbey Road GB-Thame - Oxon - OX9 3RR Phone: ax: Ankaba Zürichstr. 38a CH-8306 Brüttisellen Phone: ax: PUK - Portacables, S. L. Pol. Ind. Barcelonés C/Noguera, Nave 1 E-Abrera 08630, Cataluña Spain Phone: /91 ax: MP bolagen Box 3 S Vetlanda Phone: ax: EL-PUK Sp. z o. o, ul. Koscielna 15 PL Konstantynów Lódzki Phone: ax: Schmachtl CZ, s. r. o. Vídenská 185 CZ Vestec u Prahy Phone: ax: DIETZEL GmbH 1. Haidequerstr. 3-5 A-1111 Wien Phone: ax: Rowa-Moser Bernhard-Höfel-Str. 7 A-6020 Innsbruck Phone: ax: INPUK GmbH Naukowastr. 7b UA Lwiw Phone: ax: OOO P&K ENERGO RUS , Moscow ul. Streleckaja 6, offi ce 20 Russia Phone: ax.: Baltgeba LT Kaunas Raudondvario pl. 141 Phone: ax: OOO Energocentr Russland, , St. Petersburg ul. Mineralnaja 13A BZ Arsenal Phone: ax: UP DATAKOM Belorus, , Minsk wul. Nachimova 4 Phone: ax: PUK-WERKE S.R.L. Braşov str. 13 Decembrie ; Nr Braşov România Phone: ax: SERMES S. A. 14, Rue des frères Eberts Strassbourg cedex 1 Phone: ax: (as of )
7 PUK-Solarline
8 Contents A PUK History A2 - A3 PUK Product Groups A4 PUK-Solarline A5 PUK System statics A6 PUK Assembly A7 technical details A8
9 PUK History complete and innovative product portfolio, complemented by under floor systems with new, patented solutions, as well as assembly systems for photovoltaic systems. We supply cable support systems, cable clamps, under floor systems and assembly systems for photovoltaic systems directly to you; furthermore we will mount our products for you on your construction sites both, nationwide and abroad. Consequentially, we see ourselves as a service provider for whom customer orientation, service and flexibility are number one priority. Introducing our company The brand PUK represents an independent private enterprise, run in the best tradition of the German medium-sized businesses. PUK-WERKE was formally founded in Our history, however, goes way back to the 30ies of the last century. Today, we may look back on 70 years of successful company history. The Berlin-based businesses Herman Pohl OHG (general partnership, founded in 1951), and the Anton Klein OHG, (founded in 1935), whose shareholders decided in 1969 to bundle their business activities in the PUK- WERKE KG (limited partnership), form the roots of our company. The merge of those two companies set the course for a positive future. Synergies could be utilized, enabling the enterprise to work the German market with greater intensity. At the same time, this step laid the foundations for an efficient internationalization of our business relations. Both founding companies began their success story with the production of cable clamps known until this day as Pohl-clamps or KSV-clamps. The development and production of cable support systems was soon to follow, developing into our today s Your contact person is always nearby in our 15 sales regions all over Germany; in addition we have our own distribution companies or distribution partners in many European countries; thanks to our subsidiary P&K ENERGO, we can offer you our products even in Moscow in stock. With our Polish subsidiary EL-PUK and PUK- România we not only have our own production site for the East European market but are also able to offer you assembly on site at regional conditions. TEKOM-PUK is the leading producer of cable support systems in Turkey. This partnership opens up new possibilities not only in Turkey but also in its adjacent states and in the Arabic region. Our Spanish subsidiary PUK-Portacables and their long-time experience provide the source for our knowhow in installation of assembly systems for photovoltaic systems. A2
10 PUK History A With nearly 300 employees, PUK-Werke (without subsidiaries) generates more than 90 million Euros Europewide; with all subsidiaries combined together, over 800 employees generate a turnover of more than 180 million Euros, thus representing a steadily growing mediumsized group of companies. Of course, PUK-WERKE is certified for construction, production, delivery and assembly of cable support systems according to DIN EN ISO In cooperation with the Technical University Berlin, PUK- WERKE has developed a test facility. In this test facility, our cable support systems are being tested by the TÜV (Technical Inspection Association) according to the strict regulations of DIN EN Therefore the load-bearing capacity specifications in our main catalogue bear the TÜV sign. A3
11 PUK Product Groups Cable trays Cable clamps Underfloor systems A time-tested complete solution, consisting of: wire mesh cable trays, cable trays, cable ladders, wide-span cable ladders, supporting elements. Proven and tested reliable system solutions consisting of serial parts. Cost-effi cient due to rational serial production on state-of-the-art production facilities. The thoroughly tried and tested solution for the rational and safe mounting of one, two or three cables with a diameter of up to 175 mm. or mounting to channels of various dimensions, to sectional steel, or directly to the wall. Made of hot-dip galvanized steel, corrosion-resistant and non-magnetic high-grade steel or of aluminium. Complete solutions for all types of use, consisting of: screed fl ush duct systems, system components for double and cavity floors screed covered duct systems device cup and installation devices made of hot-dip galvanized steel, high-grade steel and synthetic material. Cable Support Systems Designed or Industry PUK-Solarline A product portfolio with highest safety standards, especially for industrial plants, consisting of: wide-span cable ladders ship ladders supporting systems profi les It goes without saying that we offer our cable trays, underfloor systems, as well as mounting structures for photovoltaic systems including assembly! The mounting system for photovoltaic system underframes is based on the use of various standard mounting profi les. The simplicity of the coaction of the profi les to the module clams, the functionality as well as the fl exible utilization are the prerequisites for the easily distinguishable user-friendly mountability of our system. Based on set parameters we offer solutions for the assembly of photovoltaic systems that are statically funded, yet at the same time unbeatably priced. A4
12 PUK-Solarline A Photovoltaic systems today Due to changes in the EEG guidelines from 2009, the solar industry in Germany is facing a secure future. In 2009, approximately 4,0 GWp (Gigawatt Peak) photovoltaic energy was installed in Germany, twice as much as in the year before, amounting to more than 50 % of the world-wide PV capacity. install PV systems on fallow agricultural or industrial sites, on landfi lls or on military conversion sites. The share of open areas and large roof structures is growing, making the installation of PV systems for the own use or for the lease of usable surfaces more and more interesting. The communal businesses as well as private investors have been showing a steadily increasing willingness to PUK-Solarline Decades worth of experience with the equipment of conventional power plants and the resulting technical challenges have also provided us with experience in delivering large amounts of material, mounting complex systems, short-notice production of all needed construction parts, as well as the corresponding engineering services. This know-how we are able to transfer onto our product group PUK-Solarline. The PUK-Solarline catalogue offers project managers and system providers secure decision support in choosing the suitable mounting system for base frames of photovoltaic systems. It offers system solutions for open space and roof constructions, for one, two, or multi-row module positions in 1- or 2-support options. Our constructions are suitable for all types of foundations. This applies to the ramming, the jolleying of ground anchors and the installation of concrete foundations. With PUK-Solarline we offer a mounting system that is 1. simple in its construction 2. statically optimized and 3. inexpensive and easy to install. Our module-independent system types are based on the system-specific variables (location, foundation, module rows, table size, etc.) and on the calculation of our system statics. We use mostly hot-dip galvanized steel profi les from our well-proven standard program. Our range of services includes the foundation, delivery and installation of the structures as well as the assembly of the modules. We will design a customized offer for every PV system according to the individual project defi nition. PUK-WERKE KG is a member of the German Solar Industry Association. A5
13 PUK System statics PUK-Software The dimensioning software PUK-SolarWare SW 10.1 enables us to dimension the best suitable type of base frame for every PV-system. Only four steps are necessary to determine the minimum amount of material and mounting work needed. PUK-SolarWare SW 10.1 is able to provide the statically verifi cation for the constructions based on the requirements of DIN 1055, the Eurocodes and DIN This structural analysis is valid in all European countries because it allows for the respective different wind load and snow load variables. The results of our calculation software deliver information on the optimized profi les and support spacing, furthermore, the profi tability of whether a 1-support or a 2-support system can be used is examined. With PUK-SolarWare SW 10.1, the developer can be completely sure that the chosen mounting system is statically tested and economically optimized. Step No. 1: Project determination Step No. 2: Geography Step No. 3: Selection of modules Step No. 4: Selection of construction A6
14 PUK Assembly A Mounting services oundation, delivery and installation of the structures as well as the assembly of the modules to various examples. 1. Ramming of the support profiles 2. Mounting of cross beams The profi les are inserted into the ground with hydraulic pile-drives. Depending on the soil class, the pillars are rammed 1.5 to 2 meters into the ground. or the mounting of cross beams with an inclined head plate in one support as well as two support systems, the necessary table incline is fi xed. 3. Mounting of longitudinal beams 4. Mounting of module carriers and modules The mounted longitudinal beams give the module table fi rst stability. They have the purpose of holding the vertical module carriers and are also intended for the very fi xing of modules for multi-row tables. With the module carriers the table obtains its statically calculated stability. The modules are mounted on it with approved module clamps. The delivery of course includes detailed mounting instructions and suggestions. A7
15 technical details Corrosion protection Since the solar support systems are used in outside areas, PUK-Werke KG offers exclusively galvanized steel parts according to the dipping method (DIN EN ISO 1461). Hot-dip galvanizing according to the dipping method (DIN EN ISO 1461) Screw joints Screw joints in outdoor areas are submitted to dynamic pressure (caused by e.g. wind). Securing precautions for screw joints such as e.g. the use of screw securing lacquer or fan-shaped washers are therefore necessary. It is absolutely pivotal in this context that the tightening torques (according to chart 1) are observed. According to DIN EN ISO 1461 the middle local layer thickness is at least 45 μm for mat. thickness 1,5 mm 55 μm for mat. thickness of 1,5 bis 3 mm 70 μm for mat. thickness of 3 bis 6 mm Mounting component parts can be delivered in highgrade steel or aluminium when indicated. Threads Steel galvanized (4.6) Material Steel galvanized (8.8) High-grade steel (μ=0,14) E (A2-70) / E4 (A4-70) M 6 3,5 11,3 7,4 M 8 8,4 27,3 17,8 M M Contact corrosion As a rule, insulation measures are not required unless the surfaces of the touching construction components are similar in size. ollowing combinations are therefore unobjectionable: - high-grade steel mounting parts (e.g. screw) / galvanized components - high-grade steel mounting parts / module clamps made of aluminium - galvanized components (bearing) / module clamp made of aluminium Critical component combinations will be examined by our engineers and marked on the binding assembly drawings. Chart 1: Tightening torques [Nm] non-binding recommended values according to VDI 2230 Potential equalisation Potential equalization between longitudinal beams is provided by the corresponding connectors. The certifi - cate for the individual application can be provided. Lightning protection PV roof systems need to be included into the given lightning protection for buildings. Building-ground The fundament can be constructed by ramming of support profi les, jolleying of ground anchors or the installation of concrete foundations. In order to calculate the fundaments and determining the ram depth geological surveys resp. test ramming and pull-out tests are mandatory. A8
16 Contents carrier systems System overview B3 - B10 Carrier section B11 - B16 B Connector B17 - B18 ittings B20 - B28 astening component parts B29 - B35
17 System overview open space systems Light Konstruktion construction B2 * ram depth depending on soil class and occurring loads
18 System overview open space systems Konstruktion Light construction B B3
19 System overview open space systems Konstruktion Medium-weight construction B4 * ram depth depending on soil class and occurring loads
20 System overview open space systems Konstruktion Medium-weight construction B B5
21 PUK-Solarline System overview open space systems Konstruktion Heavy construction B6 * ram depth depending on soil class and occurring loads
22 PUK-Solarline System overview open space systems Konstruktion Heavy construction B * ram depth depending on soil class and occurring loads B7
23 System overview roof systems Konstruktion Roof construction B8
24 System overview roof systems Roof construction B Roof construction B9
25 Contents carrier systems Description Article Page Description Article Page anchor SA B30 beam clamp SKL A B33 channel nut AM18 B34 channel nut AM18 B34 channel nut AM22 B34 channel nut AM22 B35 coupler for C-profi le CPV B17 coupler for KHA-profi le ASK 8 B18 coupler for KHA-profi le AV B18 coupler for KHU-profi le KHUV B18 coupler for Sigma-profi le SPV B17 C-profi le CP B12 cup square neck bolt RS B33 cup square neck bolt RSV B31 mating component support AT-U B28 rod coupling VM B30 Sigma-profi le SP B11 supporting piece KHU-profi le AT-ST B20 T-head bolt HS18 B35 T-head bolt HS22 B35 threaded rod GB B30 trapezium sheet bow TBB B28 washer US B32 washer RUS B33 expansion anchor SD B30 fastenings (set) BS1 B29 fastenings (set) BS2 B29 head plate BGUD B22 head plate BGUDW B22 head plate BGA 41 B24 head plate BGU 60 B24 head plate BGI B25 hexagon head bolt SES B31 hexagon nut SEM B32 hexagon nut, self-locking SEMS B32 hexagon socket head screw IK B31 I-profi le IPE B12 KHA-profi le KHA 41 B15 KHA-profi le KHA 8 B15 KHA-profi le KHA 2 B16 KHA-profi le KHA 9 B16 KHI-profi le KDI B14 KHI-profi le KHI B13 KHL-profi le KHL 50 B16 KHL-profi le KHL 50 B27 KHU-profi le KHU 60 B13 KHU-profi le KDU 60 B14 lug angle AT-BL B26 lug angle AT-W B27 mating component diagonal BGUDT B23 mating component diagonal BGUDWT B23 mating component diagonal BLD B25 mating component diagonal AT-BLI B26 mating component hinge connector AT-GV B20 mating component IPE- to KHA-profi le AT-IK B19 mating component junction plate AT-KB B21 mating component KHA- to KHU-profi le AT-KK B20 mating component KHA- to MEK-profi le AT-RUS 41 B21 mating component SP 100 to C-profi le AT-SC B19 B10
26 Carrier section SP Sigma-profi le * Article H t W y W z I y I z G mm mm cm 3 cm 3 cm 4 cm 4 kg/m SP 100x2,0* 100 2,00 15,8 4,4 79,1 13,0 4,20 SP 100x2,5* 100 2,50 19,2 5,4 95,8 15,8 5,18 SP 100x3,0* 100 3,00 22,3 6,2 111,3 18,5 6,13 * unpunched B Article H t W y W z I y I z G mm mm cm 3 cm 3 cm 4 cm 4 kg/m SP 140x1, ,50 18,0 4,4 125,9 15,4 3,72 SP 140x1, ,75 20,7 5,0 145,2 17,6 4,31 SP 140x2, ,50 28,6 6,7 200,1 23,5 6,04 SP 140x3, ,00 33,4 7,7 234,3 27,0 7,16 SP 140x4, ,00 42,5 9,4 297,2 32,8 9,30 SP 170x1, ,50 23,5 4,4 199,4 15,4 4,09 SP 170x1, ,75 27,1 5,0 230,1 17,6 5,49 SP 170x2, ,50 37,4 6,7 318,2 23,6 6,67 SP 200x1, ,50 29,4 4,4 294,3 15,4 4,47 SP 200x1, ,75 34,0 5,0 339,9 17,6 5,19 * Minimum purchasing length according to agreement, maximum length delivered: 6000 mm B11
27 Carrier section CP C-profi le * Article H t W y W z I y I z G mm mm cm 3 cm 3 cm 4 cm 4 kg/m CP 100x2, ,00 11,0 3,2 55,1 8,1 3,07 CP 100x2, ,50 13,3 3,8 66,5 9,5 3,76 CP 100x3, ,00 15,4 4,3 76,9 10,8 4,43 CP 120x2, ,00 14,0 3,3 84,1 8,7 3,40 CP 120x2, ,50 17,0 3,9 101,8 10,3 4,18 CP 140x2, ,00 17,3 3,3 120,9 9,3 3,77 CP 140x2, ,50 20,9 4,0 146,6 11,0 4,60 CP 160x2, ,00 20,8 3,4 166,3 9,7 4,11 CP 160x2, ,50 25,3 4,0 202,1 11,5 5,62 CP 180x2, ,00 24,6 3,4 221,1 10,1 4,45 CP 180x2, ,50 29,9 4,1 269,1 12,0 5,44 CP 200x1, ,50 34,9 4,1 348,7 12,4 5,86 IPE I-profi le * Article H B W y W z I y I z G mm mm cm 3 cm 3 cm 4 cm 4 kg/m IPE ,0 3,69 80,1 8,49 6,4 IPE ,2 5,79 171,0 15,90 8,7 IPE ,0 8,65 318,0 27,70 11,1 IPE ,3 12,30 541,0 44,90 13,8 IPE ,0 16,70 869,0 68,30 16,9 IPE ,0 22, ,0 101,00 21,1 IPE ,0 28, ,0 142,00 24,0 B12 * Minimum purchasing length according to agreement, maximum length delivered: 6000 mm
28 Carrier section KHI KHI-profi le Article L G mm kg KHI ,9 KHI ,9 KHI ,8 KHI ,7 KHI ,6 KHI ,5 KHI ,1 W y = 19,5 cm 3 W z = 3,0 cm 3 I y = 77,8 cm 4 I z = 6,29 cm 4 B KHU 60 KHU-profi le Article L G mm kg KHU ,8 KHU ,5 KHU ,3 KHU ,0 KHU ,9 KHU ,5 KHU ,1 W y = 7,03 cm 3 W z = 2,47 cm 3 I y = 21,10 cm 4 I z = 6,73 cm 4 * Minimum purchasing length according to agreement, maximum length delivered: 6000 mm B13
29 Carrier section KDI KHI-profi le Article L t G mm mm kg KDI ,6 KDI ,6 KDI ,7 KDI ,7 KDI ,6 KDI ,5 M max = 1600 Nm L Nm L > 1000 KDU 60 KHU-profi le Article L t G mm mm kg KDU ,5 KDU ,2 KDU ,3 KDU ,0 M max = 1000 Nm L Nm L > 1000 B14
30 Carrier section KHA 41 KHA-profi le Article L G mm kg KHA ,3 KHA ,6 KHA ,0 KHA ,3 KHA ,9 KHA ,9 W y = 4,40 cm 3 W z = 2,80 cm 3 I y = 8,98 cm 4 I z = 5,95 cm 4 B KHA 8 KHA-profi le Article L G mm kg KHA ,8 KHA ,6 KHA ,4 KHA ,1 KHA ,7 KHA ,4 W y = 2,20 cm 3 W z = 1,00 cm 3 I y = 4,48 cm 4 I z = 1,18 cm 4 * Minimum purchasing length according to agreement, maximum length delivered: 6000 mm B15
31 Carrier section KHA 2 KHA-profi le Article L G mm kg KHA ,5 KHA ,0 KHA ,5 KHA ,0 KHA ,0 KHA ,9 W y = 5,10 cm 3 W z = 2,40 cm 3 I y = 12,90 cm 4 I z = 4,40 cm 4 KHA 9 KHA-profi le Article L G mm kg KHA ,9 KHA ,9 KHA ,8 KHA ,7 KHA ,6 KHA ,2 W y = 2,72 cm 3 W z = 1,27 cm 3 I y = 5,39 cm 4 I z = 1,88 cm 4 KHL 50 KHL-profi le Article L G mm kg KHL ,66 W y = 1,9 cm 3 W z = 3,5 cm 3 I y = 3,4 cm 4 I z = 13,2 cm 4 B16 * Minimum purchasing length according to agreement, maximum length delivered: 6000 mm
32 Connector SPV coupler for Sigma-profi le Article H t G mm mm kg SPV ,00 2,37 SPV ,50 2,30 SPV ,75 1,84 Included: Page 8 x SES 10x20 B31 16 x US 10x21 B31 B CPV coupler for C-profi le Article H t G mm mm kg CPV ,5 1,77 CPV ,5 1,98 CPV ,5 2,19 CPV ,5 2,40 CPV ,5 2,61 Included: Page 10 x SES 8x20 E B31 20 x US 8x17 E B32 10 x SEM 8 E B32 * Minimum purchasing length according to agreement, maximum length delivered: 3000 mm B17
33 Connector KHUV coupler for KHU-profi le Article G kg KHUV 60 0,7 Included: Page 4 x RSV 10x20 B31 4 x US 10x21 B32 4 x SEM 10 B32 ASK 8 coupler for KHA-profi le Article G kg ASK 8 0,25 Included: Page 4 x RS 8x20E B33 4 x SEMS M8E B32 AV coupler for KHA-profi le Article G kg AV 41 0,70 Accessories available: IK 12x20 E US 13x24E SEM 12E Page B31 B32 B32 B18
34 ittings AT-IK mating component IPE- to KHA-profi le Article L B G mm mm kg AT-IK ,27 AT-IK ,47 AT-IK ,67 Included: Page 1 x SES 12x70 B31 1 x SEM 12 B32 2 x US 13x24 B32 Accessories available: SKL A Page B33 AT-SC mating component SP 100 to C-profi le Article G kg AT-SC 2,33 B Included: Page 2 x SES 10x130 B31 2 x SEM 10 B32 4 x US 10x21 B32 4 x BS1 10x20 B29 B19
35 ittings AT-GV mating component hinge connector Article G kg AT-GV 1,0 Included: Page 1 x SES 10x70 B31 1 x SEM 10 B32 2 x US 10x21 B32 AT-KK mating component KHA- to KHU-profi le Article G kg AT-KK 0,97 Included: Page 1 x SES 12x70 B31 1 x SEM 12 B32 2 x US 13x24 B32 AT-ST supporting piece KHU-profi le Article G kg AT-ST 0,58 Included: Page 2 x SES 10x20 B31 2 x SEM 10 B32 4 x US 10x21 B32 In case of loads > 2,5 kn B20
36 ittings AT-KB mating component junction plate Article t G mm kg AT-KB 3,0 0,4 B AT-RUS 41 mating component KHA- to MEK-profi le Article G kg AT-RUS 41 0,1 B21
37 ittings BGUD head plate Article G kg BGUD 1,3 Included: Page 2 x SES 10x20 B31 2 x US 10x21 B32 2 x SEM 10 B32 Accessories available: SD Page B30 BGUDW head plate Article G kg BGUDW 1,4 Included: Page 2 x SES 10x20 B31 2 x US 10x21 B32 2 x SEM 10 B32 Accessories available: SD Page B30 B22
38 ittings BGUDT mating component diagonal Article G kg BGUDT 1,1 B BGUDWT mating component diagonal Article G kg BGUDWT 0,93 B23
39 ittings BGA 41 head plate Article G kg BGA 41 1,2 Accessories available: SD SES AM() 22 Page B30 B31 B34 / B35 BGU 60 head plate Article G kg BGU 60 1,2 Included: Page 4 x SES 10x20 B31 4 x SEM 10 B31 4 x US 10x21 B32 B24
40 ittings BGI head plate Article incline (α) G kg BGI 0 1,40 BGI ,77 BGI ,75 BGI ,73 BGI ,71 Included: Page 3 x RS 10x30 B33 3 x SEM 10 B32 Article also available with other inclines. B BLD mating component diagonal Article G kg BLD 0,5 Accessories available: SD SES AM() 22 HS 18 AM() 18 Page B30 B31 B34 / B35 B35 B34 B25
41 ittings AT-BLI mating component diagonal Article G kg AT-BLI 1,45 Included: Page 2 x SES 12x30 B31 2 x US 13x24 B32 2 x SEM 12 B32 Accessories available: SD Page B30 AT-BL lug angle Article G kg AT-BL 0,12 Accessories available: SD Page B30 B26
42 ittings AT-W lug angle Article G kg AT-W 0,18 KHL 50 KHL-profi le Article L G mm kg KHL ,09 KHL ,18 KHL ,27 KHL ,35 KHL ,44 KHL ,53 KHL ,62 KHL ,71 KHL ,80 KHL ,89 KHL ,33 KHL ,77 B B27
43 ittings TBB trapezium sheet bow Article G kg TBB 0,48 AT-U mating component support Article G kg AT-U 40 0,71 B28
44 astening component parts BS1 fastenings (set) Article Set G consisting of kg/100 BS1-10x20 1x SES 10x20, 2x US 10x21, 1x SEM 10 4,1 BS1-10x25 1x SES 10x25, 2x US 10x21, 1x SEM 10 4,4 BS1-10x30 1x SES 10x30, 2x US 10x21, 1x SEM 10 4,6 BS2 fastenings (set) Article Set G consisting of kg/100 E BS2-10x20E BS2-10x25E BS2-10x30E 1x IK 10x20E, 1x US 10x21E, 1x US 10x30E, 1x SEM 10E 1x IK 10x25E, 1x US 10x21E, 1x US 10x30E, 1x SEM 10E 1x IK 10x30E, 1x US 10x21E, 1x US 10x30E, 1x SEM 10E 5,1 5,3 5,6 B B29
45 astening component parts SD expansion anchor Article Ø d P zul * P zul ** D L min G mm mm kn kn mm mm kg/100 E4 SD 8/10E ,0 4, ,6 SD 10/10E ,3 7, ,2 SD 12/10E ,7 9, ,9 SA anchor Article Ø d P zul ** D L min G mm mm kn mm mm kg/100 E4 SA 6E , ,4 SA 8E , ,5 SA 10E , ,8 SA 12E , ,6 GB threaded rod (DIN 975) Article Ø L G mm mm kg E GB M8-10E ,3 GB M10-10E ,5 GB M12-10E ,7 Stressed cross section according to DIN 276 T4: GB M8: 36,6 mm 2 GB M10: 58,0 mm 2 GB M12: 84,3 mm 2 VM rod coupling Article Ø L G mm mm kg E VM M8E ,01 VM M10E ,03 VM M12E ,05 Singular fastening * cracked and not cracked concrete B 25, resp. C20/C25 ** not cracked concrete B 25, resp. C20/C25 Subject to the valid approval documents in each case. B30
46 astening component parts RSV cup square neck bolt Article Ø d D L G mm mm mm mm kg/100 RSV 10x , ,3 E RSV 6x12E 6 1, ,5 RSV 6x16E 6 1, ,7 RSV 8x16E 8 2, ,3 RSV 10x20E 10 2, ,3 IK hexagon socket head screw (DIN 912) Article Ø d D L G mm mm mm mm kg/100 E IK 8x10E ,3 10 1,0 IK 8x20E ,3 20 1,3 IK 8x25E ,3 25 1,5 IK 8x30E ,3 30 1,7 IK 8x40E ,3 40 2,1 IK 8x50E ,3 50 2,5 IK 10x20E ,3 20 2,3 IK 10x25E ,3 25 2,5 IK 10x30E ,3 30 2,8 IK 10x40E ,3 40 3,3 IK 12x20E ,3 20 3,2 IK 12x25E ,3 25 3,6 IK 12x30E ,3 30 3,9 IK 12x40E ,3 40 4,7 IK 12x50E ,3 50 5,5 B SES hexagon head bolt (DIN 933) Article Ø D L G mm mm mm kg/100 SES 10x (16) 20 2,1 SES 10x (16) 25 2,4 SES 10x (16) 30 2,6 SES 10x (16) 80 5,1 SES 10x (16) 130 7,6 SES 12x (18) 20 3,1 SES 12x (18) 30 3,8 SES 12x (18) 40 4,5 SES 12x (18) 50 5,2 SES 12x (18) 70 6,6 E SES 8x20E ,2 SES 8x25E ,4 SES 10x20E ,1 SES 10x30E ,6 B31
47 astening component parts US washer (DIN 125) washer (DIN 9021) Article Ø d D G mm mm mm kg/100 US 10x21 10,5 2,0 21,0 0,4 US 13x24 13,0 2,5 24,0 0,6 US 17x30 17,0 3,0 30,0 1,1 E US 8x17E 8,4 1,5 17,0 0,2 US 10x21E 10,5 2,0 21,0 0,4 US 13x24E 13,0 2,5 24,0 0,6 US 10x30 10,5 2,5 30,0 1,2 US 13x40 13,0 3,0 40,0 2,7 E US 8x25E 8,4 2,0 25,0 0,7 US 10x30E 10,5 2,5 30,0 1,2 US 13x24E 13,0 2,5 24,0 0,6 SEMS hexagon nut, self-locking (similar DIN 6923) Article Ø d D A G mm mm mm mm kg/100 E SEMS 8E 8 7, ,7 SEMS 10E 10 9, ,6 SEM hexagon nut (DIN 934) Article Ø d D G mm mm mm kg/100 SEM ,0 17(15) 1,2 SEM ,0 19(18) 1,7 E SEM 8E 8 6,5 13 0,5 SEM 10E 10 8,0 17(15) 1,2 SEM 12E 12 10,0 19(18) 1,7 B32
48 astening component parts RS cup square neck bolt Article Ø d D L G mm mm mm mm kg/100 RS 10x ,3 RS 10x ,8 RS 12x ,6 E RS 8x20E ,4 RS 10x30E ,8 RS 12x30E ,6 RUS washer Article Ø d D A G mm mm mm mm kg/100 RUS 41-L , ,00 RUS 50-L ,54 B SKL A beam clamp Article d M G mm Nm kg/satz SKL A ,49 Included: Page 2 x SES 10x55 B31 2 x US 10x21 B32 2 x AM 22 M10 B32 2 x UVS M10x24 - Accessories available: KHA 41 Page B15 B33
49 astening component parts AM18 channel nut Article Ø d G mm mm kg/100 AM18 M8 8 6,0 2,6 AM18 M ,0 3,5 AM18 M ,5 4,5 E4 AM18 M8E4 8 6,0 2,9 AM18 M10E4 10 8,0 3,6 AM18 channel nut Article Ø d G mm mm kg/100 AM18 M8 8 6,0 2,7 AM18 M ,0 3,6 AM18 M ,5 4,6 AM22 channel nut Article Ø d G mm mm kg/100 AM22 M8 8 6,0 2,6 AM22 M ,0 3,5 AM22 M ,5 4,2 B34
50 astening component parts AM22 channel nut Article Ø d G mm mm kg/100 AM22 M8 8 6,0 2,8 AM22 M ,0 3,7 AM22 M ,5 4,7 B HS18 T-head bolt Article Ø L G mm mm kg/100 E4 HS18 10x30E ,0 HS18 10x40E ,5 HS18 10x50E ,0 HS22 T-head bolt Article Ø L G mm mm kg/100 E4 HS22 12x30E ,6 HS22 12x40E ,1 HS22 12x50E ,9 HS22 12x60E ,5 HS22 16x40E ,3 HS22 16x60E ,7 B35
51 Notes
52 Contents module clamps Module clamps C3 - C6 Module fastening C7 - C8 C
53 Contents module clamps Description Article Page Description Article Page module end clamp, framed MEK-G C3 module center clamp, framed MMK-G C4 module end clamp, not framed MEK-RL C5 module center clamp, not framed MMK-RL C5 module end clamp, not framed MEK-RL S C6 module center clamp, not framed MMK-RL S C6 C2
54 Module clamps MEK-G module end clamp, framed Article L k G mm mm kg AL MEK-G ,03 MEK-G ,03 MEK-G ,03 MEK-G ,03 MEK-G ,03 MEK-G ,03 MEK-G ,04 MEK-G ,04 MEK-G ,04 MEK-G ,04 MEK-G ,04 MEK-G ,04 MEK-G ,04 MEK-G ,04 MEK-G ,04 MEK-G ,04 MEK-G ,04 MEK-G ,04 MEK-G ,04 MEK-G ,04 MEK-G ,04 Accessories available: IK 8x E Page B31 C C3
55 Module clamps MMK-G module center clamp, framed Article L k G mm mm kg AL MMK-G ,04 Accessories available: IK 8x E Page B31 C4
56 Module clamps MEK-RL module end clamp, not framed Article L k G mm mm kg AL G MEK-RL ,08 Accessories available: IK 8x E Page B31 MMK-RL module center clamp, not framed Article L k G mm mm kg AL G MMK-RL ,11 Accessories available: IK 8x E Page B31 C C5
57 Module clamps MEK-RL S module end clamp, not framed Article L k G mm mm kg AL G MEK-RL S 70 6,8 0,07 Accessories available: IK 8x E Page B31 MMK-RL S module center clamp, not framed Article L k G mm mm kg AL G MMK-RL S 70 6,8 0,09 Accessories available: IK 8x E Page B31 C6
58 Module fastening Central module clamp for framed modules Module end clamp for framed modules C Central module clamp for thin layer modules Module end clamp for thin layer modules C7
59 Notes
60 Notes
61 PUK-WERKE KG PUK-KAT SOLAR EN TOPP PUK-WERKE KG Kunststoff-Stahlverarbeitung GmbH & Co. Nobelstr Berlin Germany Phone: ax: Internet: Errors and technical modifi cation subject to change, reproduction as well as electronic duplication only with our written permission. With appearance of this print all preceding documents lose their validity.
Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-...
Installation guide for the SafeLine type anchorage device Tested in compliance with EN 795: 1996 No.: SE-... Version: 09.10.2008 SE 67 Subject to technical alterations! Contents 1. General information
More informationAluGrid product sheet
AluGrid The flat roof system with optimized superimposed load quick, simple and mainly tool-free mounting reduced number of components economically effi cient system structural analysis based on the latest
More informationPV Mounting System For Crystalline Solar Module THE POWER OF ASTRONERGY
PV Mounting System For Crystalline Solar Module THE POWER OF ASTRONERGY Tile on-roof PV Mounting System Installation on tiles roof. Various quick roof hooks with different strength and structure are available.
More informationProduct Catalogue HW-B150H
Product Catalogue Content 1 Coverage and Terminology... 4 1.1 Design Standards... 4 1.2 Load Criteria... 5 1.3 Definition of Terms... 6 1.3.1 Flood Barrier... 6 1.3.2 Flood Height, effective Flood Height,
More informationPITCHED ROOF STRUCTURES
PITCHED ROOF STRUCTURES for framed and frameless photovoltaic modules Needed tools and materials: cordless screwdriver 10mm and 13mm spanners 5mm Allen key bolts, screws and tools for fixing the system
More informationLinear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors
20000 Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors 23000 22000 21000 20000 09000 08000 07000 06000 05000 04000 03000 02000 01000 823 Notes 824 Technical
More informationMachine devices, jig devices
Machine devices, jig devices 853 K0697 Rolled thread studs DIN 6379 Material: Tempered steel. KIPP Rolled thread studs DIN 6379 Order No. D L B1 B2 Approx. weight g Surface finish: Thread rolled. Class
More informationCable Trays Technical Instructions & Specifications
Cable Trays Technical Instructions & Specifications Products Catalogue Objective and Structure The company s main objective is the supply of quality products, with respect to: practical design increased
More information00MK-MA0190-EN00. Mounting System ASSEMBLY INSTRUCTIONS. Universal Light system with locking brackets, for sloped roof
00MK-MA0190-EN00 Mounting System ASSEMBLY INSTRUCTIONS Universal Light system with locking brackets, for sloped roof Rev.02 November 2014 Table of contents General instructions 2 General safety instructions
More informationCross section (useable) of cable tray. Dowel load. Weight per piece. Maximum height. Minimum length. Bracket load. Permissible load.
IRE PREVENTION Legend A B D d Ø D Cross section (useable) of cable tray Width Diameter Dowel load Weight per piece H Hmax L Lmin M P Pzul SW t incl. Height Maximum height Length Minimum length Torque Bracket
More informationKIRÁLY TRADING KFT H-1151 Budapest Mogyoród útja 12-14 tel: 061307-3801 Email_pzoli@kiralytrading.hu. Clamps Clamping devices
04000 Clamps Clamping devices 23000 22000 21000 20000 09000 08000 07000 06000 05000 04000 03000 02000 01000 297 04010 Adjustable straps Tempered steel 1.1191 Black oxide finish nlm 04010-101 Suitable thrust
More informationInstallation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale
Installation information METTLER TOLEDO MultiRange DW150 / DW150T wall scale DW150 / DW150T wall scale Contents Contents Page 1. Installation... 2 1.1 Preparatory work... 2 1.2 Installing the wall plates
More informationASSEMBLY INSTRUCTIONS Residential Roof solutions
ASSEMBLY INSTRUCTIONS Residential Roof solutions CROSSRAIL System USA Table of contents TABLE OF CONTENTS THE COMPANY SAFETY REGULATIONS MATERIALS REQUIRED TOOLS REQUIRED ASSEMBLY TERMS AND CONDITIONS
More information19 DYNAmax Free Standing Server C A B I N E T s
9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=600mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide
More informationPermanent Stainless Steel Anchorage Point for Concrete, Solid Masonry and Steel Constructions
ABS-Lock X / X - SR Permanent Stainless Steel Anchorage Point for Concrete, Solid Masonry and Steel Constructions The ABS-Lock X system was developed to provide both a secure single anchorage point for
More informationmechanics PP-Profiles Panel Profiles PT-Profiles T-Groove Plates RE-Profiles Rectangular Profiles PU-Profiles Universal Profiles
Overview PP-Profiles Panel Profiles PP 50 PP 100 PP 150 PP 200 PP 0 B 4 PT-Profiles T-Groove Plates B 5 PT PT 50 RE-Profiles Rectangular Profiles B 6 RE 15 RE 30 RE40 RE65 PU-Profiles Universal Profiles
More informationUNIVERSAL RAILING, STEEL
RAILINGS Page Universal Railing, steel 108-109 Large Module Railing, steel 110-111 Allround Railing, aluminium 112-113 Module Railing, aluminium 114-115 Standard Type Railing, aluminium 116-117 107 UNIVERSAL
More information19 DYNAmax Free Standing Server C A B I N E T s
9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide
More informationHORIZONTAL INSTALLATION
THERMO/SOLAR Žiar s.r.o. MANUAL FOR INSTALLATION PV SUPPORTING FRAMES HORIZONTAL INSTALLATION Technical alternation reserved A1410 1 12/2014 CONTENT ORD.NO. PAGE Mounting information 3 Mounting, flat roof
More informationPPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
More informationLinkeo 19" freestanding cabinets
87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3
More informationInstallation manual ValkPitched - Insert
Van der Valk Solar Systems TRCKING ND FIXED SOLR MOUNTING SYSTEMS Installation manual ValkPitched - Insert Version 10 EN General user instructions Solar mounting systems Congratulations on buying a Van
More information39HQ Airovision Air Handling Units
39HQ Airovision Air Handling Units Mounting instructions CONTENTS 1 - TRANSPORT AND LIFTING INSTRUCTIONS... 3 1.1 - General... 3 1.2 - Transport and storage... 3 1.3 - Roof edge protection during transport
More informationDescription. Dimensions. Features. www.pwb-encoders.com. precision works better
Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature
More informationSteel for wind power applications
Steel for wind power applications Ovako keeps our world in motion Wind power Combined with modern technology, wind power an ancient source of energy offers a wide range of opportunities in the areas of
More informationOBTAINED FROM PHOTOVOLTAIC SYSTEMS SUPPORTED BY METALSISTEM STEEL STRUCTURES
Aimed at cutting the overall cost of solar plants, GREEN ENERG OBTAINED FROM PHOTOVOLTAIC SYSTEMS SUPPORTED BY METALSISTEM STEEL STRUCTURES METALSISTEM s Research and Development Department has developped
More informationAssembly Instructions for the InteliTrack 3000 Rail Tracking System
Assembly Instructions for the InteliTrack 3000 Rail Tracking System InteliTrack is a trademark of Sedona Solar Technology. Sedona Solar Technology 16 April 2013 1 1. Before you begin WARNING Safety equipment
More informationDock Hardware & Accessory Products Catalog
Dock Hardware & Accessory Products Catalog Product Page # Product Page # Angle Brackets/Clips 8 Back Up Plate 5 Backing Plate/Hurricane Stop 10 Carriage Bolt Sets 4 Chain Retainer 10 Connector Pin Set
More informationKnürr Smaract. Knürr Smaract. CompactRack
CompactRack Features Ample space for components and cabling provided in an efficient, compact design. The innovative frame concept with triangular extrusions ensures low weight while maintaining high stability.
More information08. SEK IDC CONNECTORS
. IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these
More informationlindab duct suspension & support system Duct suspensions & Support systems
lindab duct suspension & support Duct suspensions & Support s lindab duct suspension & support Content Duct suspensions & Support s Duct suspension Duct suspension FB... DRSN... 0 DRSNR... 0 Channels and
More informationWOLFFKRAN. 1 Schedule drawing. 1.1 Schedule drawing, WOLFF 6023.6clear. max. hook height above ground. Data WOLFF 6023.6clear
1 Schedule drawing 1.1 Schedule drawing, WOLFF 6023.6clear [X] max. hook height above ground Data WOLFF 6023.6clear Item Crane type Design Type of setup Basis of calculation Payload torque Hoist winch
More informationAA Solar and Sun Power Plus
AA Solar and Sun Power Plus www.aasolar.co.nz www.sunpowerplus.co.nz -1- Contents Chapter Title Page 1 General information 3 2 Safety and Installer Responsibilities 4 3 Technical Specifications 5 4 Tools
More informationTELESCOPE Motorized Lighting Suspension
TELESCOPE Motorized Lighting Suspension Mod. 8400 FEATURES The De Sisti TELESCOPE is a single point suspension specifically designed to provide rigidity and stabilization of all moving parts. It can extend
More informationModular Access Floor for Data Center. From Rack to Row to Room to Building
Modular Access Floor for Data Center From Rack to Row to Room to Building Why using Scneider Electric modular access floor in Data Centers The evolution of modern Data Centers emphasizes specific exigencies
More informationTARIFF CODE and updates standard
TARIFF CODE and updates standard No HS CODE AHTN CODE PRODUCT DESCRIPTION PRODUCT TYPE STANDARDS IDENTIFIED 7207 Semi finished products of iron or non alloy steel Containing by weight less than 0.25% of
More informationRAIL FREE SOLAR ROOF MOUNT
RAIL FREE SOLAR ROOF MOUNT Utilizes EcoFasten Solar s patented technology Rock-it system Designed with the installer in mind. EcoFasten Solar specializes in solar roof attachments that are the easiest
More informationEuropean Technical Approval ETA-12/0500
ETA-Danmark A/S Kollegievej 6 DK-2920 Charlottenlund Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet www.etadanmark.dk Authorised and notified according to Article 10 of the Council Directive 89/106/EEC
More informationRotary actuators Rotary wing drives Series RAK. Brochure
Brochure 2 Rotary wing drives, angle of rotation: 30-270 Rotary wing drive, double-acting axis geometry: single 4 Rotary wing drives, angle of rotation: 90-270 Rotary wing drive, double-acting axis geometry:
More informationSECTION 15140 - PIPE HANGERS AND SUPPORTS
Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the
More informationLayher. Protective Systems. More Possibilities. The Scaffolding System. Layher Keder Roof and Keder Hall Instructions for Assembly and Use
Layher Keder Roof and Keder Hall Instructions for Assembly and Use Quality management certified according to DIN EN ISO 9001:2000 by German TÜV-CERT Protective Systems Layher More Possibilities. The Scaffolding
More informationDear costumers, You have just received our new catalogue with KOPOS KOLIN a.s. offer of metal cable support system products. Those types of products
Dear costumers, You have just received our new catalogue with KOPOS KOLIN a.s. offer of metal cable support system products. Those types of products were firstly introduced on the market in year 2007.
More informationDirectory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.
Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11
More informationTwo most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:
Two most common lock nut groups: 1. PREVAILING TORQUE a design feature of the lock nut produces friction between threads of mated components thereby increasing the force needed to tighten as well as loosen
More informationLEGACY REPORT ER-5110. www.icc-es.org. ICC Evaluation Service, Inc. Reissued November 1, 2003. Legacy report on the 1997 Uniform Building Code
LEGACY REPORT Reissued November 1, 2003 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900
More informationContents. Company presentation...1. Plain system...2. Inclined systems...5. Solar park solution...10. Particular solutions...12. Details...
Contents Company presentation...1 Plain system...2 Inclined systems...5 Solar park solution...10 Particular solutions...12 Details...14 Products...16 Company presentation Suports Desarrollo y Soluciones
More informationCABLE SUPPORT SYSTEMS
CABLE SUPPORT SYSTEMS eaturing the CADDY CAT HP J-Hook System Why CADDY CAT HP? Why Choose CADDY CAT HP over tray? ast and Easy to Install Much faster installation compared to conventional cable or ladder
More informationSEISMIC VELOCITY TRANSDUCER T1-40
SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute
More informationData Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list
VITOSOL 100 Flat collectors for the utilisation of solar energy Data Sheet Part nos. and prices: see price list File in: Vitotec 1 Manual, Index 16 Vitosol 100 Type s 1.7 Vitosol 100 Type s 2.5 Vitosol
More informationSCAFFOLDING PRODUCT TECHNICAL GUIDE. Scaffold Couplers General Technical and Application Manual. Genuine Safety. Outstanding Service.
SCAFFOLDING PRODUCT TECHNICAL GUIDE Scaffold Couplers Genuine Safety. Outstanding Service. Introduction Scaffold couplers are essentially the fundamental component that is used to assemble tube-and-coupler
More informationIntelligent storage solutions
Pallet Racking Intelligent storage solutions Supply chains must function efficiently. Whether handling pallets of fruit, containers of hazardous materials, racks of clothing or boxes of nails; products
More informationScrew Thread Design. Rev. 3-4-09
Screw Thread Design Screw Thread Fundamentals A screw thread is defined as a ridge of uniform section in the form of a helix on either the external or internal surface of a cylinder. Internal threads refer
More informationInstallation manual Solar Tracker
Van der Valk Solar Systems TRACKNG AND FXED SOLAR MOUNTNG SYSTEMS nstallation manual Solar Tracker Version 07 EN General user instructions Solar mounting systems Congratulations on buying a Van der Valk
More informationChapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
More informationHS-Steel-Classic. Curing chambers for the concrete block industry in a proven steel version
ANLAGENTECHNIK HS-Steel-Classic Curing chambers for the concrete block industry in a proven steel version + special galvanising + simple assembly due to snap-in connections and building kit system We build
More informationPipe Clamps and Accessories
Products 4.0 Products 4.1 Connection options to pipe clamps with Triple-Thread Connector NT 3G (M16, M10, M8) 4.2 Connection options to pipe clamps with Triple-Thread Connector NT 3G (3/8", M12, M10) 4.3
More informationFixturing systems Fixturing systems for measurement technology
Fixturing systems Fixturing systems for measurement technology Innovations and new additions to range Sets Spannfix Eco complete set The set contains different supports, extension elements and stop units.
More informationPOLE MOUNT SYSTEM-3 INSTALLATION
1 May 2014 POLE MOUNT SYSTEM-3 INSTALLATION The Pole Mount System-3 is an easy to install and flexible system designed to allow ONE SYSTEMS loudspeaker products to be mounted to pole structures. The only
More information19 NETbox SOHO Network Wall Mounting Cabinets FAMILY
9 NETbox SOHO Network Wall Mounting Cabinets FAMILY DETAILS: Framework- Top/Bottom Cases: Multi Folded Automated Bending technology applied framework and top/bottom cases, provides a heavy duty structure
More informationGivare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
More informationInstallation manual ValkPitched - Clamp
Van der Valk Solar Systems TRCKING ND FIXED SOLR MOUNTING SYSTEMS Installation manual ValkPitched - Clamp Version 16 EN General user instructions Solar mounting systems Congratulations on buying a Van
More informationThis mount uses concrete parking bumpers and a Davis tripod to create a mounting solution for nonpenetrable
NON-PENETRATING FLAT ROOF MOUNT Application Note 18 For Any Davis Weather Station Installed on a Mounting Tripod Introduction This application note describes various mounting solutions for non-penetrable
More informationSECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS
SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for electrical
More informationFAG Hydraulic nuts. Technical Product Information
FAG Hydraulic nuts Technical Product Information Contents Application 2 Design 2 Design variants 3 Pressure generators, connectors 4 Dimension tables for FAG hydraulic nuts (metric) 6 Dimension tables
More informationHilti, Inc. 5400 South 122 nd East Avenue Tulsa, OK 74146. 1-800-879-8000 www.hilti.com
Attached are page(s) from the 2014 Hilti North American Product Tech Guide. For complete details on this product, including data development, product specifications, general suitability, installation,
More informationHVU with HAS/HAS-E rod adhesive anchor
HVU with HAS/HAS-E rod HVU with HAS/HAS-E rod adhesive anchor Mortar system Benefits Hilti HVU foil capsule HAS HAS-R HAS-HCR rod - suitable for non-cracked concrete C 20/25 to C 50/60 - high loading capacity
More informationCOB panel supports for multipole connectors
TCQ + TSFS (...CMS, alternative) CMS TSFS Use The system makes it possible to use multipole connectors within electric panels without the traditional metallic housing as protection is assured by the electric
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationInstallation Guide of Sunrise Solartech PV Modules. Term 2013. Contents. Purpose of this guide. General. Safety precaution for installing a solar
Installation Guide of Sunrise Solartech PV Modules Term 2013 Contents Purpose of this guide General Safety precaution for installing a solar Photovoltaic system Product Identification Mechanical Installation
More informationPOWERS Controls No. 4 Pneumatic Damper Actuator
POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000
More informationSSG PRODUCTS FOR SHIPS AND OFFSHORE
6.1 SSG PRODUCTS FOR SHIPS AND OFFSHORE SSG workshop cabinets, tables and shelving system specially adapted to be used on-board ships and offshore. Developed in close cooperation with users from these
More informationDepartment: Quality Assurance presenting its state-of-the-art testing facilities
Department: Quality Assurance presenting its state-of-the-art testing facilities 2 Dresselhaus, stands for long-time tradition and innovation. Supreme quality demands, qualified personnel and continuous
More informationRPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
More informationRAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo
Connectors, Clamps, Compensating Devices, Insulators and Safety Equipment for Overhead Catenary Lines RAILWAY CATENARY SYSTEMS Components and Systems for the Electrification of Railway Lines. Welcome to
More informationPREMIUM CLASS PHOTOVOLTAICS
PREMIUM CLASS PHOTOVOLTAICS ENGLISH A CNBM COMPANY PREMIUM CLASS PHOTOVOLTAICS Our successful flagship is the brand PowerMax. PowerMax modules offer a high energy yield (kwh per kwp), possible due to broad
More informationPrecision Miniature Load Cell. Models 8431, 8432 with Overload Protection
w Technical Product Information Precision Miniature Load Cell with Overload Protection 1. Introduction The load cells in the model 8431 and 8432 series are primarily designed for the measurement of force
More informationResidential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
More informationRiMatrix S Make easy.
RiMatrix S Make easy. 2 RiMatrix S Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power
More informationSECTION 4: Cable Ladder Stainless Steel & Aluminium
SECTION 4: Cable Ladder & Aluminium Type 3/50 (NEMA 6A) Type 4/70L Type 5/112 (NEMA 20C) > 4:3 > 4:4 > 4:5 Aluminium Type 4/70A (NEMA 16B) Ladder Splice Plates > 4:7 > 3:18 Page 4:1 Cable Ladder General
More information6720616592.00-1.SD. Flat roof. Rack Mounting. Installation instructions 6 720 647 036 (2010/11) AU
6720616592.00-1.SD Flat roof Rack Mounting AU Installation instructions 2 Contents AU Contents 1 Key to symbols and safety instructions....... 3 1.1 Explanation of symbols................ 3 1.2 Safety
More informationEJOT Spiralform. The thread formers for metal. EJOT The Quality Connection
EJOT Spiralform The thread formers for metal EJOT The Quality Connection Imprint Editor: EJOT GmbH & Co. KG Industrial Fasteners Division D 57319 Bad Berleburg Layout and Realisation: EJOT GmbH & Co. KG
More informationGUARDRAIL POST STEEL
GUARDRAIL POST STEEL Guardrail posts meeting materials certification are evaluated and checked for: 1. Dimensional acceptance 2. Physical test results a. Chemical b. Physical 3. Galvanized or painted coating
More informationINSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
More informationWisconsin Building Products Evaluation
Safety & Buildings Division 201 West Washington Avenue P.O. Box 2658 Madison, WI 53701-2658 Evaluation # 200813-O Wisconsin Building Products Evaluation Material Best Management Standards for Foundation
More informationThe Stabilizer TM. Benefits. www.griptite.com. Supplemental support system for sagging beams and floor joists within a crawl space
The Stabilizer TM Supplemental support system for sagging beams and floor joists within a crawl space Pre-drilled holes in steel plate allow for connection to beam or floor joists. Benefits Levels and
More informationDIGITUS Network & Server Cabinets. UNIQUE Series
DIGITUS Network & Server Cabinets UNIQUE Series Benefits - Server Rack 4-Point locking system front door 3-point locking system rear door Swing handle lock with profile zylinder in front and rear door
More informationEuropean Technical Assessment ETA-10/0153 of 10/06/2015
ETA-Danmark A/S Göteborg Plads 1 DK-2150 Nordhavn Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet ww.etadanmark.dk Authorised and notified according to Article 29 of the Regulation (EU) No 305/2011 of
More informationTECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR
TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR 1.1.0 SCOPE : This specification covers design, manufacture, testing at manufacture s works before
More informationSOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
More informationU-TK Transformer Kit. Parts included. Technical specifications. Engineering Data Sheet. Universal transformer kit. Power rating up to 100 W or 200 W
Engineering Data Sheet U-TK Transformer Kit Universal transformer kit Power rating up to 100 W or 200 W High quality toroidal transformer and connectors Power tapping (full, half or quarter power) and
More informationSolar Mounting Catalogue
Solar Mounting Catalogue Tile roof, metal sheet roof, flat roof, whatever type of your roof is, we can supply you all rooftop mounting solutions. With high quality of anodized aluminium and galvanized
More informationAMF112 Instruction Manual
AMF112 Instruction Manual Scan here to view product demo and install videos or visit san.us/103 Milestone AV Technologies 6436 City West Parkway Eden Prairie, MN 55344 USA Customer Service Americas: 800-359-5520
More informationLift-off hinge. Rising hinge. Standard hinge. Heavy duty hinge. Parliament hinge. Spring hinge. Double action spring hinge. Concealed mortise hinge...
Door Hinges Contents Butt hinges Lift-off hinge Rising hinge Standard hinge Heavy duty hinge Parliament hinge Spring hinge Double action spring hinge Concealed hinges Concealed mortise hinge... Pivot
More informationInForm Mobile Units. Selection. Equipment trolley, filing trolley Printer/PC trolley Overhead/demo trolley
Selection Equipment trolley, filing trolley Printer/PC trolley Overhead/demo trolley Basic mobile unit Basic mobile with vertical profiles Installation options Functional shelf, low Functional shelf, inclinable
More informationGISMA UNDERWATER CONNECTORS SERIES 40
CONTENTS SEITE / PAGE GENERAL 4 GENERAL ARRANGEMENT 5 DESIGN MECHANICAL FEATURES 7 FIBRE OPTIC FEATURS 7 ELECTRICAL FEATURES 7 REFERENCE SYSTEM 8 REFERENCE SYSTEM CONTACTS 9 CONTACT LAYOUTS 9 SUGGESTIONS
More informationCOMPONENTS IP 2 INSTRUMENT PANEL INSTRUMENT PANEL ASSEMBLY ASSIST GRIP RETAINER RH FRONT PILLAR GARNISH RH FRONT DOOR OPENING TRIM WEATHERSTRIP RH
INSTRUMENT PANEL INSTRUMENT PANEL INSTRUMENT PANEL PRECAUTION 1 1. PRECAUTION FOR VEHICLE WITH SRS AIRBAG AND SEAT BELT PRETENSIONER (a) Some of these operations may affect the SRS airbag system. Read
More informationopti-drän system Keeps your basement and building dry
opti-drän system Keeps your basement and building dry Last modified: January 0 DRAINAGE SYSTEMS ELECTRICAL SYSTEMS BUILDING TECHNOLOGY INDUSTRIAL PRODUCTS Professional building drainage with the opti-drän
More informationDiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
More informationGONAR - SYSTEMS INTERNATIONAL TUNNELING AND GEOTECHNICAL SYSTEMS
GONAR - SYSTEMS INTERNATIONAL TUNNELING AND GEOTECHNICAL SYSTEMS 1 GSI System Technical Data Technical Data Unit R25 R32L R32N R32S R38 R51N T76N T76S T103N T103S Outer mm 25 32 32 32 38 51 76 76 103 103
More informationSaferand easierinstallation
EN 85-07 Saferand easierinstallation IföSigninstallationsystem andifösignbuilt-incistern www.ifosanitar.com/sign Aneffectivesolution withmanyadvantages. Ifö Sign installation system makes life a little
More information