Cam switches. CQ Series
|
|
- Felix Randall
- 7 years ago
- Views:
Transcription
1 Cam switches CQ Series
2 CQ Series Overview The range of cam switches CQ series includes ratings from to A with insulation voltage of 69V. According to the latest industrial application standards, CQ series offers IP terminals protection degree and IP6 handle protection degree. Available with different mounting systems: rear panel with screws, base mounting with screws or snap mounting on DIN rail (EN ) with escutcheon plate for mm standard knock-out. Available schemes for every application: ON-OFF switches, line switches, cam switches for motor control, ammeter and voltmeter switches. Easy made wiring Rear access to terminals screws for rear mounting versions. Front access to terminals screws for base mounting versions Escutcheon plate for mm (.77 ) standard knock-out mm (.77 ) plate for fixing in standard panel/distribution boards slots. Available schemes for ON-OFF switches, line switches, ammeter and voltmeter switches. 6 CATALOGUE
3 cam switches Class V self-extinguishing thermoplastic housing Positive opening and double break contacts, silver alloy made Assembled with metal shaft and without threaded stud bolts to ensure maximum operating reliability and minimum dimensions Captive plus-minus terminals screws Base mounting All base mounting items (BL6 - BK6 handles) include a 7 mm (6.89 ) shaft. CATALOGUE 6
4 CQ Series Technical data IEC 97- EN 697- Rated insulation voltage Rated operating voltage Rated impulse withstand voltage Rated thermal for open switch Rated thermal for enclosed switch Rated operation frequency Power dissipation for each pole Rated operating Ie AC-A Switching resistive loads, including moderate overloads AC-A Switching of mixed resistive and inductive loads, including moderate overloads AC-A Connecting and disconnecting under no load conditions Rated operating power AC-A Switching of motor loads or other highly inductive loads AC- Squirrel cage motors: starting, switching off motors during running AC- Squirrel cage motors: starting, plugging, inching AC- Control of a.c. elettromagnetic loads Rated breaking capability in category in AC-A (cos φ=,) Short circuit protection Rated short time withstand (s) Rated short-circuit make capacity Rated conditional short-circuit With fuses class gg Technical data UL/CSA Rated insulation voltage Rated operating voltage General Use Current Rated operating power phases - poles phases - poles Mechanical characteristics Mechanical life Connections according to IEC 97- and EN 697- Connecting capability Connecting capability with flexible wires Connecting capability with solid wires Connection terminal screw dimensions Screw tightening torque Protection degree IEC 9 EN 69 Terminals Ambient conditions Operating ambient temperature Storage ambient temperature Withstand to constant humid according to IEC 668 Withstand to cyclic humid according to IEC CATALOGUE
5 cam switches CQ CQ6 CQ CQ Ui V Ue V Uimp kv 6 6 Ith A 6 Ithe A 6 Hz W,,6,8, Ie A 6 Ie A V Kw (A) (), (7) 9 (8) () V Kw (A) 7, () 9 (6) (7) 8, () V Kw (A) 7, () 9 () () 8 (7) 69V Kw (A) 7, (8) 9 (9) (6) 8, (9) V Kw (A),8 (9) () 6, () 8, (6) V Kw (A), () 7, () () (7) V Kw (A), (8) 7, () (6) () 69V Kw (A), (6) 7, (8) () () V Kw (A), (), (),7 () () V Kw (A),7 (), () (7), () V A 6 8 V A 6 8 V A 8 8 V A Icw A 6 Icm A - ka V A Ui UL/CSA V Ue UL/CSA V Ie UL/CSA A V UL/CSA Hp,/,, /, - - V UL/CSA Hp,/, /, - - V UL/CSA Hp / / - - V UL/CSA Hp / 7,/ - - 8V UL/CSA Hp / 7,/7, - - 6V UL/CSA Hp 7,/7, / Cycles x 6, - Cycles/hour Min-Max mm x,-, x,-, x,-6 x,-6 Min-Max AWG Min-Max mm x,- x,- x,- x,- - Tipo M, M, M M - Nm,,,8,8 IP C - + C CATALOGUE 6
6 CQ Series Standard plates and knobs Q Rear mounting with screws, grey plate 8x8mm (.89x.89 ), black knob, IP6 Q6 Rear mounting with screws, grey plate 6x6mm (.x. ), black knob, IP6 Rear mounting with screws RL6 Rear mounting with screws, yellow plate 67x67mm(.6x.6 ), red padlockable knob (max padlocks), IP6 BL6 Base mounting with screws or with snap mount on DIN rail, yellow plate 67x67mm(.6x.6 ), red padlockable knob (max padlocks), door interlock in ON position, IP6 Base mounting with screws or snap on DIN rail DDN Base mounting with screws or snap mount on DIN rail, escuteon plate for standard mm (.77 ) knock-out, black knob, IP 66 CATALOGUE
7 Optional plates and knobs QG Rear mounting with screws, yellow plate 8x8mm (.89x.89 ), red knob, IP6 QG6 Rear mounting with screws, yellow plate 6x6mm (.x. ), red knob, IP6 Rear mounting with screws RK6 Rear mounting with screws, grey plate 67x67mm(.6x.6 ), black padlockable knob (max padlocks), IP6 BK6 Base mounting with screws or witn snap on DIN rail, grey plate 67x67mm (.6x.6 ), black padlockable knob (max padlocks), door interlock in ON position, IP6 Base mounting with screws or snap mount on DIN rail CATALOGUE 67
8 CQ Series Rear mounting Q Q6 ON-OFF switch poles A CQQ 6A CQ6Q CQ6Q6 A A CQQ6 ON-OFF switch poles A CQQ CQQ6 6A CQ6Q CQ6Q6 6 A A CQQ6 CQQ6 ON-OFF switch poles 7 A CQQ CQQ6 6A CQ6Q CQ6Q6 6 8 A A CQQ6 CQQ6 Change-over switch pole U U A 6A CQQ CQQ6 R/L A A 68 CATALOGUE
9 cam switches Rear mounting Q Q6 Change-over switch poles U U V V A 6A CQ6Q CQ66Q CQ66Q6 6 R/L S/L A A CQ6Q6 CQ6Q6 Change-over switch poles U U V V W W A 6A CQ7Q CQ67Q CQ7Q6 CQ67Q6 7 R/L S/L T/L A A CQ7Q6 CQ7Q6 Change-over switch poles U U V V W W N N A 6A CQ9Q CQ69Q CQ69Q6 9 R/L S/L T/L N/O A A CQ9Q6 CQ9Q6 Reversing switch poles R S T A 6A CQ8Q CQ68Q CQ8Q6 CQ68Q6 8 U V W A A CQ8Q6 CQ8Q6 CATALOGUE 69
10 CQ Series Rear mounting Q Q6 Changing switch Dahlander pole W R S A 6A CQ9Q CQ69Q CQ9Q6 CQ69Q6 9 T U V A A CQ9Q6 CQ9Q6 STAR-DELTA Starter T S Y R A 6A CQ6Q CQ6Q6 W X V U Z A A CQQ6 CQQ6 Reversing switch poles T S W V R U A 6A A A CQ6Q Voltmeter switch concatenated voltages L-L L-L L-L 7 A CQ6Q CQ6Q6 6A 6 A A 7 CATALOGUE
11 cam switches Rear mounting Q Q6 Voltmeter switch concatenated voltages and phase voltages L-L L-L L-L L-N L-N L-N A 6A CQ8Q CQ8Q6 8 6 A A Ammeter switch pole transformers 9 A CQQ CQQ6 6A 6 A A CATALOGUE 7
12 CQ Series Rear mounting Base mounting* RL6 BL6 ON-OFF switch poles with padlockable handle A 6A CQRL6 CQ6RL6 CQBL6 CQ6BL6 6 A A CQRL6 CQRL6 CQBL6 CQBL6 ON-OFF switch poles with padlockable handle 7 A 6A CQRL6 CQ6RL6 CQBL6 CQ6BL6 6 8 A A CQRL6 CQRL6 CQBL6 CQBL6 * Base mounting switches are supplied with standard 7mm (6.89 ) shaft 7 CATALOGUE
13 cam switches Rear mounting Base mounting* RK6 BK6 ON-OFF switch poles with padlockable handle A 6A CQRK6 CQ6RK6 CQBK6 CQ6BK6 6 A A CQRK6 CQRK6 CQBK6 CQBK6 ON-OFF switch poles with padlockable handle 7 A 6A CQRK6 CQ6RK6 CQBK6 CQ6BK6 6 8 A A CQRK6 CQRK6 CQBK6 CQBK6 * Base mounting switches are supplied with standard 7mm (6.89 ) shaft CATALOGUE 7
14 DDN Version Construction data DDN is the solution proposed by BREMAS for mounting the switch in panel/distribution boards standard slots, with mm (.77 ) plate. The main mounting system is snap mount on DIN rail, otherwise it s possible to fix the switch with screws with 8mm (.89 ) or 7mm (.9 ) interaxis between the holes. Available schemes for ON-OFF switches, line switches, ammeter and voltmeter switches. Gray escuteon plate, black knob, IP. DDN version A Rated nominal 6A DN7 CQDN7DDN CQ6DN7DDN DN8 CQDN8DDN CQ6DN8DDN DN9 CQDN9DDN CQ6DN9DDN DN CQDNDDN CQ6DNDDN DN6 CQDN6DDN DN8 CQDN8DDN DN CQDNDDN 7 CATALOGUE
15 s cam switches Switches plate scheme function circuit diagram contact/element description DN7 Change-over switch pole Contact Element Angle DN8 Change-over switch poles 6 8 Contact Element Angle DN9 Change-over switch poles Contact Element Angle DN Multi step switch pole steps with OFF 6 8 Contact Element Angle L-L L-L L-L DN6 Voltmeter switch concatenated voltages 7 L-L L-L L-L Contact Element Angle L L L R S T 7 V L-L L-L L-L L-N L-N L-N DN8 Voltmeter switch concatenated voltages and phase voltages 6 L-N L-N L-N L-L L-L L-L Contact Element Angle L L L R S T N 6 V DN Ammeter switch pole transformers 6 9 Contact Element Angle L L L 6 A 9 R S T CATALOGUE 7
16 CQ Series - Accessories Plates and knobs Legend included Description Type Degrees FINRL6Q Rear mounting with screws, yellow plate 67x67mm (.6x.6 ), - 9 red padlockable knob (max padlocks), IP6 FINRK6Q Rear mounting with screws, grey plate 67x67mm (.6x.6 ), - 9 black padlockable knob (max padlocks), IP6 FINQQ Rear mounting with screws, plate 8x8mm (.89x.89 ), black knob, IP FINQ6Q Rear mounting with screws, plate 6x6mm (.x. ), black knob, IP Optional shafts Description PALBL L=mm (.8 ) square section mm (. ) PALBL L=mm (9.68 ) square section mm (. ) 76 CATALOGUE
17 Dimensions cam switches Rear mounting - Q/Q6/QG/QG6 handles C (..6 ) (.9 ) B B (mm) (in) Q-QG.9 Q6-QG6.8 Stages no 6 CQ -6 D =,.9 C = x.7x.7 CQ - D =,.9 C = 6X6.x. L (mm) L (in) L (mm) L (in) 8, 6, 7, 8,, , 6, 7, 88,, Rear mounting - RL6/RK6 handles 9 (. ) Stages no CQ -6 D =, L (mm) 6,.9 C = x L (in).8.7x.7 CQ - D =,.9 C = 6X6.x. L (mm) L (in) 6,.8 (..6 ) Rear mounting - BL6/BK6 Handles Switching angle 9, padlockable (max padlocks) Overall lenght (min-max)** for different shaft lenghts: 9 (. ) Stages no L Stages no L 7. DIN 677/ (.9 ) (..6 ) 7* (mm) * (in).6 -. CQ -6 D =,.9 C = x.7x.7.8 (mm) (in) (mm) (in).6 -. CQ - D =,.9 C = 6X6.x. 7* (mm) * (in) (mm) (in) (mm) (in) * Standard shaft, bundled ** Minimum length obtainable by cutting the shaft. CATALOGUE 77
18 CQ Series - Dimensions - Drilling templates Base mounting - DDN 7, (.8 ) (.7 ) Drilling templates Rear mounting Base mounting, (. ) DIN 677/ (. ) 9, (.7 ) 7, (. ) Drilling templates Escutcheon plate Switch (.6 ) 6 (.6 ) 6 (.6 ) 8 (. ) 8 (. ). (. ) 6 (. ), (.7 ) 8 (.89 ) - CQ -6 7 (.9 ) - CQ - For fixing with screws in alternative to snap mount on DIN rail 6 (. ) Drilling templates - DDN, (.7 ) 8 (.89 ) Fixing with screws in alternative to snap mount on DIN rail 78 CATALOGUE
Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More informationAF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More information3 - Cam switches. Contents 0. Complete switches, 10 A. Complete switches, 12 and 20 A. Adaptable sub-assemblies, 12 and 20 A
Contents - Cam switches Selection guide............................................. page / Complete switches, A b Front mounting by Ø or Ø mm, with x mm front plate... page / v Switches and stepping switches..............................
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationLC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationGeneral Informations 2 Technical data 3 Basic designs 4-8
Contents Page General Informations 2 Technical data 3 Basic designs 4-8 Cam Switches On-Off switches, Changeover switches 9-12 Star-Delta switches 13-15 Multi speed switches 16-20 Control switches 21-23
More informationManual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
More informationPSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More informationABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More informationVEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control
More information3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
More informationSIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.
The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved
More informationNF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationLow voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More informationMini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
More informationControl Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
More informationCam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5
Eaton Wiring Manual / Page Overview - ON-OFF switches, main switches, maintenance switches - Changeover switches, reversing switches - (Reversing) star-delta switches - Multi-Speed Switches - Interlock
More informationTHE ADVANTAGES ARE YOURS
THE ADVANTAGES ARE YOURS The new switches/discrepancy switches "R0-DR0" have special characteristics that make them very different from the normal switches on the market. Listed below are some of the many
More informationRotary Disconnect Switch Specifications
Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationSafety detection solutions
Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationREVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)
SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY
More information49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
More informationThermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
More informationTechnical catalogue. Modular DIN rail components Installation contactors
Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a
More information48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
More informationTHERMAL RELAYS, MOTORSTARTERS
THERMAL RELAYS, MOTORSTARTERS MH mini thermal relay plugged version H0K thermal relay with adapter H0K thermal relay plugged version T I thermal relay plugged version H thermal relay with current transformer
More informationSUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
More informationTechnicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW
ADS8 IP54 Direct-On-Line Starter Technical Focus Replaces ADS7 Rated up to 9kW New ADS8 Motor Starter The new ADS8 range of motor starters replaces the successful ADS7 range which was introduced 20 years
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationNDQ5 Series. Automatic Transfer Switch. Shanghai Liangxin Electrical CO.,LTD
Shanghai Liangxin Electrical CO.,LTD Address: No. 668 Heng An Road, Pu Dong New District, Shanghai Zip: 200137 Tel: 86-21-5012789 Fax: 86-21-58675966 E-mail: client@sh-liangxin.com LINE 1 LINE 3 LINE 5
More informationD-Line Contactors, Overload Relays and Accessories
D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................
More informationManual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
More informationPlug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
More informationSoft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D 40 16 E 0 VD00
Soft Starter Three Phase General Purpose Soft Starters Type RSGD Soft starting and soft-stopping of 3-phase squirrel cage motors 45mm wide IP20 housing Operational Voltage: RSGD40 (220-400V), RSGD60 (220-600V)
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional
More information48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
More informationZS10 Screw Clamp Terminal Block
Technical Datasheet 1SNK 161 004 D0201 ZS10 Screw Clamp Terminal Block Feed-through Catalogue Page 1SNK 161 004 S0201 10 mm² 6 AWG 8 mm 0.315 in Spacing Features and Benefits 53 2.09" Save space by connecting
More informationType: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationHS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.
y HS5D First in the Industry Miniature Interlock Switches First in the Industry Head Removal Detection Function for Safer Performance (*based on IDEC research, July 09) New Generation Miniature Interlock
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationPlug and Socket Devices SolConeX 16 A Series 8570
www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationA sophisticated design for a demanding field. prima series
A sophisticated design for a demanding field prima series 2 nd edition 2003 prima compact horizontal interlocked sockets carefully studied A size for all versions with or without fuses. Extends horizontally
More informationSafety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
More informationVoltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationFUSERBLOC. 20 to 1250 A Manual operation. 142 General Catalogue 2011-2012 SOCOMEC. Fuse combination switches
FUSERBLOC Fuse combination switches appli_8_a fuser_548_a cat fuser_59_a cat fuser_52_a cat 2 to 25 A Manual operation Function FUSERBLOC are manually operated multipolar fuse combination switches. They
More informationType: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationW DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6
W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W SCHRACK-INFO Any mains connection If using 4-pole. switches with 3 or 2-poles, ensure connection acc. to assembly instructions
More informationCatalog. Modular DIN rail components Installation contactors
Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation
More informationCatalogue May 2015. EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole
Catalogue May 2015 EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole Contents Introduction 1 Overview 1-pole 2 Overview 2-pole 3 Overview 3-pole 4 Overview 4-pole 5 Electronic Fuse Monitoring 6 Busbar
More informationVario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
More informationABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
More informationFeatures. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationSingle-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
More informationMicro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.
Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More informationThermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
More informationELECTROMAGNETIC DISC BRAKES
ELECTROMAGNETIC DISC BRAKES TYPE 66E 15/30 52.121 Hand release Lining wear adjustment Torque adjustment 4 holes ø13 DISC SIZE Ø A Braking torque Nm Regulated from (40-100%) Reaction on the shaft N Control
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More informationProduct and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
More informationD7 Series Standard and Full Featured. Standard DPDT 24V AC 120V AC 240V AC 12V DC 24V DC 120V AC 110V DC 240V AC 6V AC 6V DC 12V AC 12V DC 24V AC
April 00 D Series Standard and Full Featured - Catalogue Number Structure Table -. D Series Catalogue Numbering System Family Type DPR = Standard Relay DPF = Full Featured Relay Contact Configuration =
More informationThree-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
More informationType: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
More informationNEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION. Super Solution
NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION Super Solution Low voltage circuit breakers Susol LV circuit breakers Super Solution Contents Overview Electrical characteristics Trip units Accessories
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More information7000 Series Buccaneer
The all plastic and metal construction of the - circular that combine the ease of use of a quick coupling mechanism with proven environmental sealing for signal and mains power. Designed and independently
More informationAbsolute Rotary Encoder E6CP
Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the
More informationMEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
More informationIEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide
- long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationBreakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM
Breakers and Switches Switches Switch-disconnectors OT, OETL, OTDC and OTM Switch-disconnectors OT 16...2500, OETL 3150, OTDC16...32 and OTM160...2500 Contents 4 Product overview, features 8 Technical
More informationCommand devices Pull-wire emergency stop switches One-side operation ZS 71 range 6.1 6.1.1 6.1.1.1. 312 Schmersal -10 0 10 20 30 40 50 60 70 T [] C
.1.1.1 One-side operation ZS 71 range 40 30 ø10 10 53,5(63)* 6 8 18 24 105 33 56 12 22 M20x1,5 52 17,5 42 15 Features To EN 418 / IEC 60947-5-5 Metal enclosure 2 contacts Small body 2 cable entries M20
More informationRY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
More informationPendant control stations 6
Characteristics 6 Environment Conformity to standards EN/IEC 6097-5-1 EN/IEC 600-, UL 508, CSA C- n EN/IEC 6097-5-5 and EN/ISO 850 for versions with trigger action Emergency stop Product certifications
More informationOutdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationBimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More information3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,
Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41
More informationTP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12
Bulletin DB-111B12 TP-C2 Motor Operator CLEAVELAND / PRICE INC. 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177 FAX (724) 864-9040 Email: sales@cleavelandprice.com Cleaveland/Price Type TP-C2 Motor Operator
More informationBulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
More informationThermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
More informationUncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M
Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection
More informationAUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A
AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components
More informationZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket
Technical Datasheet SNK636D00 Catalogue Page SNK636S00 ZS-SF-T Screw Clamp Terminal Blocks For x 0 and x fuses - with test socket - Protect your circuit with x and x0 fuse terminal blocks (fuse not supplied
More information