Pendant control stations 6

Size: px
Start display at page:

Download "Pendant control stations 6"

Transcription

1 Characteristics 6 Environment Conformity to standards EN/IEC EN/IEC 600-, UL 508, CSA C- n EN/IEC and EN/ISO 850 for versions with trigger action Emergency stop Product certifications Special version, with suffix H7 : UL Listed A600-Q600, CSA A600-Q600, CCC, GOST Protective treatment Standard version TH Ambient air temperature For operation C For storage C Vibration resistance 15 gn ( Hz) conforming to IEC Shock resistance 100 gn conforming to IEC Electric shock protection Class II conforming to IEC 610 Degree of protection IP 65 conforming to IEC 6059 IK 08 conforming to EN 5010 Mechanical durability 1 (in millions of operating cycles) Enclosure Double insulated polypropylene, coloured yellow throughout Cable entry Rubber sleeve with stepped entry diameter for cable Ø 8 Ø 6 mm Contact block characteristics Rated operational characteristics ZB BEppp, XEN Gpppp, XAC Spppp XEN Tpppp Thermal current (lthe) A 10 a AC-15: A600 or Ue = 600 V, le = 1. A or Ue = 0 V, Ie = 3 A c DC-: Q600 or Ue = 600 V, le = 0.1 A or Ue = 50 V, Ie = 0.7 A a AC-15: A300 or Ue = 0 V, le = 3 A c DC-: Q300 or Ue = 50 V, le = 0.7 A conforming to EN/IEC Appendix A Rated insulation voltage (Ui) ZB BEppp, XEN Gpppp, V 600, degree of pollution 3 XAC Spppp XEN Tpppp V 00, degree of pollution 3, conforming to EN/IEC Rated impulse withstand voltage (U imp) kv 6, conforming to EN/IEC Positive operation Mushroom head pushbutton: N/C contact with positive opening operation conforming to EN/IEC Appendix K Contact operation N/C or N/O slow break Resistance across terminals MΩ y 5 Operating force N Operators - with contact: 10 - with contact: 8 - with additional N/O contact: 5 - with additional N/C contact: 3 Terminal referencing Conforming to CENELEC EN 500 Short-circuit protection 10 A cartridge fuse type gg (gl) Connection mm Screw and captive cable clamp terminals. Clamping capacity: min. 1 x 0.5 mm, max., with or without cable end: x 1.5 mm or 1 x.5 mm. 6.3 mm clips (on request), please consult your Customer Care Centre. Operational power Conforming to EN/IEC Appendix C. Utilisation categories AC-15 and DC-. Operating rate: 3600 operating cycles/hour. Load factor: 0.5. a.c.supply a 50/60 Hz d.c. o Inductive circuit supply c Power broken in W for 1 million operating cycles Millions of operating cycles 1 0,6 0, 0, Ithe 30 V 7 V...8 V Voltage V 8 0 o W , Current in A References: page 30075/3 Dimensions: page 30075/ Application schemes: page 30075/15 Presentation: page 30075/ EN_Ver.3.indd

2 References 6 Complete stations ready for use DF56553 For control of single-speed motors Functions Number of operators Contact block(s) and scheme Reference Weight Per direction For Emergency stop XAC A XAC A71 XAC A81 XAC A DF5655 XAC A7 XAC A8 1 trigger action latching Emergency stop Ø 30 mm operator ZA BS8 (1) XAC A7 (1) XAC A8 (1) DF5655 N/C N/C XEN T9 XAC A71 (1) N/C N/C XEN T9 XAC A81 (1) XAC A71 XAC A81 (1) Trigger action latching Emergency stop pushbuttons conform to standards EN/IEC 600-, EN/ISO 850, Machinery directive 98/37/EC and standard EN/IEC EN_Ver.3.indd 3

3 References (continued) 6 Complete stations ready for use DF56555 For control of single-speed motors (continued) Functions Number of operators Contact block(s) and scheme Reference Weight Per direction For Emergency stop XAC A XAC A XAC A71 XAC A81 1 trigger action latching Emergency stop Ø 0 mm operator ZA BS8 (1) XAC A7 (1) XAC A8 (1) N/C N/C XEN T9 XAC A71 (1) XAC A7 XAC A8 XAC A71 XAC A N/C N/C XEN T9 XAC A81 (1) XAC A XAC A XAC A671 XAC A681 XAC A67 XAC A trigger action latching Emergency stop Ø 0 mm operator ZA BS8 (1) XAC A67 (1) 0.85 XAC A68 (1) (1) Trigger action latching Emergency stop pushbuttons conform to standards EN/IEC 600-, EN/ISO 850, Machinery directive 98/37/EC and standard EN/IEC Characteristics: page 30075/ Dimensions: page 30075/ Application schemes: page 30075/15 Presentation: page 30075/ EN_Ver.3.indd

4 References (continued) 6 Complete stations ready for use DF56556 DF56557 For control of single-speed motors (continued) Functions Number of operators 6 1 trigger action latching Emergency stop Ø 0 mm operator ZA BS8 (1) Contact block(s) and scheme Reference Weight Per direction For Emergency stop N/C N/C XEN T9 N/C N/C XEN T9 XAC A671 (1) XAC A681 (1) I O 8 on 7 operators and on the 8 th operator XAC A XAC A671 XAC A681 XAC A871 XAC A881 XAC A For control of -speed motors Functions Number of operators Contact block(s) and scheme Reference Weight Per direction For Emergency stop N/O N/O staggered XEN G91 XAC A XAC A91 XAC A9 XAC A91 1 trigger action latching Emergency stop Ø 30 mm operator ZA BS8 (1) N/O N/O staggered XEN G91 N/O N/O staggered XEN G91 N/C N/C XEN T9 XAC A9 (1) XAC A91 (1) (1) Trigger action latching Emergency stop pushbuttons conform to standards EN/IEC 600-, EN/ISO 850, Machinery directive 98/37/EC and standard EN/IEC EN_Ver.3.indd 5

5 References (continued) 6 Complete stations ready for use DF56558 For control of -speed motors (continued) Functions Number of operators Contact block(s) and scheme Reference Weight Per direction For Emergency stop N/O N/O staggered XEN G91 XAC A XAC A91 1 trigger action latching Emergency stop Ø 0 mm operator ZA BS8 (1) N/O N/O staggered XEN G91 N/O N/O staggered XEN G91 N/C N/C XEN T9 XAC A9 (1) XAC A91 (1) (a) (b) N/O N/O staggered (a) XEN G91 XAC A XAC A9 XAC A91 (b) DF56558 XAC A9 N/O N/O staggered (a) XEN G91 1 trigger action latching Emergency stop Ø 0 mm (b) operator ZA BS8 (1) XAC A9 (1) N/O N/O staggered (a) XEN G91 N/C N/C XEN T9 XAC A91 (1) (b) XAC A9 XAC A91 (1) Trigger action latching Emergency stop pushbuttons conform to standards EN/IEC 600-, EN/ISO 850, Machinery directive 98/37/EC and standard EN/IEC Characteristics: page 30075/ Dimensions: page 30075/ Application schemes: page 30075/15 Presentation: page 30075/ EN_Ver.3.indd

6 References 6 Empty enclosures 530 Empty enclosures Description Enclosure comprising: - the enclosure, - internal mounting plate, - protective cable sleeve, - internal cable clamp, - suspension ring, - cable tie (for tightening sleeve onto cable). Number of cut-outs Reference Weight XAC A XAC A03 (1) 0.0 XAC A0 XAC A XAC A05 (1) 0.65 XAC A03 6 XAC A XAC A XAC A Variable composition stations, factory assembled Use the order form on page 30075/17 to defi ne the required confi guration. Equipment: contact blocks, operating heads (control and signalling), complementary accessories See separate components, page 30075/8 (1) Enclosures with 3 cut-outs XAC A03 and 5 cut-outs XAC A05 cannot be fi tted with a mounting adaptor for base mounted units. The first cut-out can only be used for the Emergency stop function. XAC A EN_Ver.3.indd 7

7 References 6 Separate components and spare parts Contact blocks for front mounting Description Application Function Scheme Reference Weight Single block, spring return slow break Single-speed N/O p p N/C p p N/C N/O N/O simultaneous (1) XEN G speed N/C N/O N/O staggered (1) XEN G XEN G91 XEN G Double block, latching slow break () Single-speed N/O N/O XEN G XEN G3781 XEN G3791 XEN T9 N/O N/C Isolating switch, slow break, for front mounting For mounting in enclosures XAC A03 (frontal cut-out) XAC A05, A06, A08 (frontal or base cut-out) XEN G Application Function Scheme Reference Weight Emergency stop N/C N/C N/C XEN T with positive opening operation (1) Only for use with XAC A9ppp operators. () Not suitable for use with the following operating heads: ZA BB, ZA BD, ZA BG and ZA BS.. Characteristics: page 30075/ Dimensions: page 30075/ Application schemes: page 30075/15 Presentation: page 30075/ EN_Ver.3.indd

8 References (continued) 6 Separate components and spare parts 5300 Contact blocks for base mounting Description Function Scheme Reference Weight Spring return slow break (1) N/O XAC S XAC S10p N/C XAC S N/O N/O XAC S N/C N/C XAC S N/C N/O XAC S ZB BV006 Pilot light bodies for front mounting Description Supply voltage Scheme Reference Weight Direct supply Bulb not included () y 00 V X1 ZB BV X 530 Direct supply, through resistor Incandescent BA 9s base fi tting 0 V bulb included 30 V X1 ZB BV X ZB BV007 (1) Not suitable for use with 3-position operating heads ZA BD and ZA BG or for mounting in enclosures XAC A039 and XAC A03. () Bulb type for use with direct supply units: BA 9s base fi tting incandescent bulb U y 0 V or neon bulb 0 V y U y 00 V. Maximum power:.6 W, maximum Ø: mm, maximum length: 8 mm. See page EN/ EN_Ver.3.indd 9

9 References (continued) 6 Separate components and spare parts 5303 XAC A9pp Operating heads for front mounting Description Colour Sold in lots of Unit reference Weight Booted operators White 10 XAC A Black 10 XAC A Green 10 XAC A Red 10 XAC A Yellow 10 XAC A Blue 10 XAC A Brown 10 XAC A Operating heads for front or base mounting Description Colour Type Reference Weight Trigger action latching Red Ø 30 mm ZA BS Emergency stop (1) Turn to release Ø 0 mm ZA BS DF53893 ZA BS8 ZA BS9 Trigger action latching Emergency stop () Key release (n 55) Key withdrawal in rest (unactuated) position Selector switches (3), standard handle (Not to be used with XEN Gpppp contact blocks) Red Ø 30 mm ZA BS Ø 0 mm ZA BS Black position, stay put ZA BD position, stay put () ZA BD Key switches () (key n 55) Key withdrawal in left and right-hand position position, stay put ZA BG position, stay put () ZA BG5 0.0 ZA BDp Key switch () (key n 55) Key withdrawal in left-hand position position, stay put ZA BG ZA BGp Key switch () (key n 55) Spring return from right to left Key withdrawal in left-hand position Key switch () () (key n 55) Key withdrawal in centre position -position ZA BG position, stay put ZA BG3 0.0 DF56559 Wobblesticks (5) Operates in all directions for fast stop Black ZA BB Red ZA BB ZA BBp (1) Trigger action latching Emergency stop pushbuttons conform to standards EN/IEC 600-, EN/ISO 850, Machinery directive 98/37/EC and standard EN/IEC () Other key numbers available on request, please consult your Customer Care Centre. (3) Selector switches available with other mechanical functions, please consult your Customer Care Centre. () Only suitable for front mounting. (5) Base mounting recommended. Characteristics: page 30075/ Dimensions: page 30075/ Application schemes: page 30075/15 Presentation: page 30075/ EN_Ver.3.indd

10 References (continued) 6 Separate components and spare parts ZA BV0p 5300 Pilot light heads Description Colour Reference Weight For use with incandescent bulbs Lens cap with bezel and fixing nut White ZA BV Green ZA BV DL1 Cpppp DL1 CFppp Red ZA BV Yellow ZA BV Blue ZA BV DF5655 XAC A009 For use with neon bulbs Lens cap with bezel and fixing nut Clear ZA BV Green ZA BV Red ZA BV Yellow ZA BV Clear ZA BV XAC A960 DF ZB SZ3 Bulbs Description Voltage Sold in lots of Incandescent BA 9s base fi tting Maximum power:.6 W Maximum Ø: mm Maximum length: 8 mm Unit reference Weight 6 V 10 DL1 CB V 10 DL1 CE V 10 DL1 CE V 10 DL1 CE XAC B961 XAC A971 0 V 10 DL1 CE Neon BA 9s base fi tting Maximum power:.6 W Maximum Ø: mm Maximum length: 8 mm 0 V 10 DL1 CF V 10 DL1 CF V 10 DL1 CF XAC A98 XAC A Complementary accessories, tools Description Reference Weight Protective cable sleeve For cable Ø 8 to mm XAC A For cable Ø 8 to 6 mm XAC A Mechanical interlock for With fi xing screws XAC A operators Blanking plug With seal and fi xing nut ZB SZ Tightening tool for fi xing nut Adaptor for self-supporting cable type BBAP ZA BZ Mounted with protective sleeve for cable Ø 8 to 6 mm XAC B Lower support ring XAC A XBF X Protective guards for base mounted units For selector switch (standard handle) or Emergency stop head pushbutton For key switch or key release latching Emergency stop head pushbutton XAC A XAC A Bulb extractor For BA 9s base fi tting bulbs XBF X 0.05 ZA BZ EN_Ver.3.indd

11 References 6 Legends 30 x 0 mm with symbols conforming to NF E Function Symbol Reference Weight Function Symbol Reference Weight Raise, slow ZB BY Lower, slow ZB BY White bacround, black symbol Raise, fast ZB BY Lower, fast ZB BY Raise, slow-fast ZB BY Lower, slow-fast ZB BY Black bacround, white symbol 0 Red bacround, white symbol Right, slow ZB BY Left, slow ZB BY Right, fast ZB BY Left, fast ZB BY Right, slow-fast ZB BY Left, slow-fast ZB BY Forward, slow ZB BY Reverse, slow ZB BY Forward, fast ZB BY Reverse, fast ZB BY Forward, slow-fast ZB BY Reverse, slow-fast ZB BY Slew right, slow ZB BY Slew left, slow ZB BY Slew right, fast ZB BY Slew left, fast ZB BY Slew right, slow-fast ZB BY Slew left, slow-fast ZB BY Slow ZB BY Fast ZB BY Klaxon ZB BY Start-Klaxon ZB BY Start ZB BY Stop ZB BY Characteristics: page 30075/ Dimensions: page 30075/ Application schemes: page 30075/15 Presentation: page 30075/ EN_Ver.3.indd

12 References 6 Legends 30 x 0 mm 530 White Black Red Text Reference Weight b Start functions: white characters on black bacround b Stop functions: white characters on red bacround Text Reference Weight ZB BY01 Blank Black or red bacround ZB BY White or yellow bacround ZB BY Black White Yellow With English text With French text For pushbuttons For pushbuttons Start ZB BY Marche ZB BY Stop ZB BY Arrêt ZB BY Forward ZB BY Avant ZB BY Reverse ZB BY Arrière ZB BY ZB BY101 Up ZB BY Montée ZB BY Down ZB BY Descente ZB BY Right ZB BY Droite ZB BY Left ZB BY Gauche ZB BY On ZB BY En service ZB BY Off ZB BY Hors service ZB BY Power on ZB BY Sous tension ZB BY Slow ZB BY Lent ZB BY Fast ZB BY Vite ZB BY Klaxon ZB BY Klaxon ZB BY For selector switches For selector switches Arrêt-Marche ZB BY66 Off-On ZB BY Hors-en ZB BY With special texts b Specify text when ordering, b lines maximum, characters per line. White characters on black bacround White characters on red bacround Other versions ZB BY Black characters on white bacround ZB BY Black characters on yellow bacround Legends with texts in other languages. Please consult your Customer Care Centre. ZB BY ZB BY EN_Ver.3.indd

13 Dimensions 6 Dimensions XAC A pendant stations for control circuits internal Ø Number of operators b b c (1) For and 3-way XAC A stations. () For to 8-way XAC A stations. (3) With trigger action Emergency stop head operator. Protective guards XAC A98 XAC A Characteristics: page 30075/ Dimensions: page 30075/ Application schemes: page 30075/15 Presentation: page 30075/ EN_Ver.3.indd

14 Application schemes 6 Application schemes (typical examples) For control of single-speed reversing motor Contact blocks For control of -speed reversing motor contact blocks XEN G91 S1 S1 S S S S1 KM A1 KM1 A1 A A KM1 KM KM A A1 A A1 A A1 KM: high speed contactor EN_Ver.3.indd 15

15 Presentation 6 Variable composition stations, factory assembled EN_Ver.3.indd

16 Order form (specimen suitable for photocopying) 6 Variable composition stations, factory assembled Customer Schneider Electric Industries Company Order N Delivery date Sales offi ce - Subsidiary Co. Order N Enter the order with XAC A09 reference Unit reference of empty enclosure, see page 30075/7 Number of identical stations Enclosure price (1) XAC A 1 Legends see page 30075/ Contact blocks or pilot light bodies see page 30075/8 Operating heads or pilot light heads or blanking plug see page 30075/10 Reference Unit price Reference Unit price Reference Unit price Total price Unit mounted in base of enclosure (if required) (Except when using XAC A03 and XAC A05) Complementary accessories, see page 30075/ (cross the appropriate box or boxes) Description Reference Unit price Adaptor for self-supporting cable type BBAP for XAC B961 use with cable entry sleeve Ø 8 to 6 mm 15 Lower support ring XAC A Protective guard for selector switch (std. handle) or XAC A98 Emergency stop head pushbutton, mounted in base 17 Protective guard for key switch or key release XAC A983 Emergency stop head pushbutton, mounted in base Mechanical interlocking () Reference Quantity Unit price 17 XAC A009 Factory assembly: Number of heads or blanking plugs to be fi tted X Additional cost XAC 9VA for fi tting of 1 head or 1 blanking plug Total price of assembled pendant station (1) Obtain the empty enclosure price. () Connect with a line the ways which require mechanical interlocking. Examples: combinations possible Combinations not possible EN_Ver.3.indd 17

Pendant control stations 6

Pendant control stations 6 References Empty enclosures 0 XACA0 Empty enclosures Description Enclosure comprising: - the enclosure, - internal mounting plate, - protective cable sleeve, - internal cable clamp, - suspension ring,

More information

Safety dialogue solutions

Safety dialogue solutions General Presentation Emergency stop trip wire switches Emergency stop trip wire switches are designed to: b avert hazards (dangerous phenomena) at the earliest possible moment, or to reduce risks which

More information

XB4BS8445 red Ø40 Emergency stop pushbutton Ø22 trigger latching turn release 1NO+1NC

XB4BS8445 red Ø40 Emergency stop pushbutton Ø22 trigger latching turn release 1NO+1NC Characteristics red Ø40 Emergency stop pushbutton Ø22 trigger latching turn release 1NO+1NC Complementary CAD overall width CAD overall height CAD overall depth Terminals description ISO n 1 Product weight

More information

K1H005P body for 2-speed motor switch - 3-pole A - for Ø 22 mm

K1H005P body for 2-speed motor switch - 3-pole A - for Ø 22 mm Characteristics body for 2-speed motor switch - 3-pole - 60-12 A - for Ø 22 mm Complementary Main Switching angle 60 Range of product Product or component type Component name [Ith] conventional free air

More information

K1H014MLH cam ammeter switch - 4 circuits A - screw mounting

K1H014MLH cam ammeter switch - 4 circuits A - screw mounting Characteristics cam ammeter switch - 4 circuits - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing

More information

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

XCKP2121G11 limit switch XCKP - th.plastic roller lever plung. Hor - 1NC+1NO - snap - Pg11

XCKP2121G11 limit switch XCKP - th.plastic roller lever plung. Hor - 1NC+1NO - snap - Pg11 Characteristics limit switch XCKP - th.plastic roller lever plung. Hor - 1NC+1NO - snap - Pg11 Complementary Switch actuation Electrical connection Cable entry Contacts insulation form Positive opening

More information

Limit switches 0. Round rod lever, thermoplastic, Ø 6 mm L = 200 mm (3) Round rod lever, glass fibre, Ø 3 mm

Limit switches 0. Round rod lever, thermoplastic, Ø 6 mm L = 200 mm (3) Round rod lever, glass fibre, Ø 3 mm Presentation Limit switches OsiSense XC Standard, format EN Conforming to CENELEC EN Variable composition Square rod lever, steel, U mm L = mm () Round rod lever, glass fibre, Ø mm L = mm () ZCK D ZCK

More information

Push Buttons and Operator Interface Specifier s Guide Type XAL Control Stations

Push Buttons and Operator Interface Specifier s Guide Type XAL Control Stations Push Buttons and Operator Interface Specifier s Guide Type XAL Control Stations Catalog 2005 File 9001 CONTENTS Description.....................................................Page General Information................................................

More information

Page 32939/6. Guard switch type XCS LF (metal) XCS LE (plastic)

Page 32939/6. Guard switch type XCS LF (metal) XCS LE (plastic) Presentation Safety detection solutions 3 Safety switches with solenoid interlocking of the actuator With mushroom head pushbutton for escape release Page / Page / Plastic, type Safety switches with solenoid

More information

52 x 72 x 30 (2.05 x 2.83 x 1.18) N/C + N/O; N/C + N/C N/C + N/O N/C + N/O; N/C + N/C

52 x 72 x 30 (2.05 x 2.83 x 1.18) N/C + N/O; N/C + N/C N/C + N/O N/C + N/O; N/C + N/C Selection Guide Osiswitch Classic Design Classic Catalog number XCKM XCKL XCKJ Enclosure Metal Fixed or plug-in body, - C (- F) Features conduit entries or + C (+8 F) versions Modularity Head + Body +

More information

Limit switches 5. Osiswitch Classic. Page 5/80. Page 5/80. Page 5/82. Page 5/82

Limit switches 5. Osiswitch Classic. Page 5/80. Page 5/80. Page 5/82. Page 5/82 Presentation, general characteristics switches Metal, type XCK J Conforming to CENELEC EN 41 b XCK J fixed body with 1 cable entry v With head for linear movement (plunger) Page /8 v With head for rotary

More information

XCMN2121L1 limit switch XCMN - th.plastic roller lever plung. Hor - 1NC+1NO - snap - 1 m

XCMN2121L1 limit switch XCMN - th.plastic roller lever plung. Hor - 1NC+1NO - snap - 1 m Characteristics limit switch XCMN - th.plastic roller lever plung. Hor - 1NC+1NO - snap - 1 m Complementary Switch actuation Electrical connection Cable length Cable composition Wire insulation material

More information

conforming to IEC IP 66, IP 67 and IP 68 (1) conforming to IEC IK 06 conforming to EN Bodies and heads: Zamak zinc alloy

conforming to IEC IP 66, IP 67 and IP 68 (1) conforming to IEC IK 06 conforming to EN Bodies and heads: Zamak zinc alloy Universal, XCMD Environment characteristics Conforming to standards Product certifications Protective treatment Ambient air temperature Products IEC 60947-5-1, EN 60947-5-1, UL 508, CSA C- n 14 Machine

More information

Push Button and Operator Interface - Type BW, SKYP & XACA Pendant Stations Type XACA Pendant Stations Specifications

Push Button and Operator Interface - Type BW, SKYP & XACA Pendant Stations Type XACA Pendant Stations Specifications Type XACA Pendant Stations Specifications XAC pendant stations are designed for standard or medium duty control circuit applications. The enclosures are made from rugged, double insulated thermoplastic

More information

Safety detection solutions

Safety detection solutions Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

02/11/2015

02/11/2015 83893 plastic solenoid locking switch 838932 2-pole Part number 83893201 Monitoring of moving guards for machines with a stopping time which is greater than the time taken to access the danger zone Locked

More information

Catalog February Control and Signaling Diameter 22mm XB4 / ZB4

Catalog February Control and Signaling Diameter 22mm XB4 / ZB4 Catalog February 2004 Control and Signaling Diameter 22mm XB4 / ZB4 General Control and signalling units Ø 22 0 Description The Ø 22 range of metal control and signalling units comprises: Complete units

More information

ZB5AD3 black selector switch head Ø22 3-position stay put

ZB5AD3 black selector switch head Ø22 3-position stay put Product data sheet Characteristics ZB5AD3 black selector switch head Ø22 3-position stay put Complementary CAD overall width CAD overall height CAD overall depth Product weight Mechanical durability Station

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 01 A1 08 02 A2 A4 05 A5 external rubber gasket external rubber gasket external rubber gasket external rubber gasket external rubber gasket 21 25 4 69 5 stainless

More information

RM4UB35 single-phase network control relay RM4-U - range V

RM4UB35 single-phase network control relay RM4-U - range V Characteristics single-phase network control relay RM4-U - range 160..220 V Complementary [Us] rated supply voltage Supply voltage limits Control threshold undervoltage Control threshold overvoltage Output

More information

Beacons and indicator banks Ø 70 optimum Harmony XVE. Catalogue March

Beacons and indicator banks Ø 70 optimum Harmony XVE. Catalogue March Beacons and indicator banks Ø 70 optimum Harmony XVE Catalogue March 04 Contents Beacons and indicator banks b Presentation............................................ page b Description.............................................

More information

General_technical_data Series

General_technical_data Series Slow-make switching element Switching system The double-break, slow-make switching element is equipped with one or two independent contact systems, acting as normally open or normally closed contact. The

More information

Catalog April Cam switches Complete products 10 A

Catalog April Cam switches Complete products 10 A Catalog April Cam switches Complete products A General Cam switches Complete products A The range of K cam switches ( A rating) comprises only complete switches. These products are more specifically designed

More information

Limit switches OsiSense XC Special. For hoisting applications type XCR, XCKMR, XCKVR Catalog

Limit switches OsiSense XC Special. For hoisting applications type XCR, XCKMR, XCKVR Catalog For hoisting applications type XCR, XCKMR, XCKVR Catalog Introduction For hoisting applications, types XCR, XCKMR, XCKVR b XCR v With head for rotary movement operators, spring return to the Off position

More information

Schneider Electric. TeSys Vacuum Contactors. June. Building a New Electric World

Schneider Electric. TeSys Vacuum Contactors. June. Building a New Electric World TeSys Vacuum Contactors June 2002 Building a New Electric World Selection guide, characteristics Contactors 5 Selection guide Contactor size LC1-V160 LC1-V320 LC1-V610 For utilisation category AC-3 Maximum

More information

WEG Pushbuttons, Switches and Indicators. (Ø 22mm) CSW Series

WEG Pushbuttons, Switches and Indicators. (Ø 22mm) CSW Series WEG Pushbuttons, Switches and Indicators (Ø 22mm) CSW Series Heavy-duty glass-filled polyimide construction IP66 degree of protection Reliable contact blocks LED & Incandecent lamps WEG Pushbutton, Switches

More information

Control stations and enclosures 2

Control stations and enclosures 2 Presentation 2 Control stations and enclosures 2 2 36030-EN_Ver6.0.indd General 2 Control stations and enclosures 2 XAL D and XAL K control stations are available in two forms: b Complete. b For customer

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

RM4TR32 three-phase network control relay RM4-T - range V

RM4TR32 three-phase network control relay RM4-T - range V Characteristics three-phase network control relay RM4-T - range 300..430 V Complementary [Us] rated supply voltage Control threshold undervoltage Control threshold overvoltage Width Output contacts Main

More information

Square D General Purpose Relays

Square D General Purpose Relays Square D General Purpose Relays Class 0R plug-in relays 0RS (SPDT) 0RS (DPDT) 0RS3 (3PDT) 0RS (PDT) Catalog 0 Contents Class 0R plug-in relays bbspecifications....................................................

More information

Heavy-Duty 30.5 mm Metal PushbuttonS

Heavy-Duty 30.5 mm Metal PushbuttonS Heavy-Duty 30.5 mm Metal PushbuttonS 10250T25R 10250T Series 10250T122 smaller than actual size. Heavy-Duty Zinc Die Cast Construction Enclosed Silver Contacts with Reliability Nibs Diaphragm Seals with

More information

3 - Cam switches. Contents 0. Complete switches, 10 A. Complete switches, 12 and 20 A. Adaptable sub-assemblies, 12 and 20 A

3 - Cam switches. Contents 0. Complete switches, 10 A. Complete switches, 12 and 20 A. Adaptable sub-assemblies, 12 and 20 A Contents - Cam switches Selection guide............................................. page / Complete switches, A b Front mounting by Ø or Ø mm, with x mm front plate... page / v Switches and stepping switches..............................

More information

RM17UAS. Main. Product or component type. Product specific application. Relay monitored parameters

RM17UAS. Main. Product or component type. Product specific application. Relay monitored parameters Characteristics voltage control relay RM17-U - range 65..260 V AC Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main Range of

More information

RM35UB3. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA Minimum switching current

RM35UB3. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA Minimum switching current Characteristics voltage control relay RM35-U - range 114..329 V AC Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Voltage detection threshold Main Range

More information

RE7TL11BU on-delay timing relay s - 24 V AC DC - 1OC

RE7TL11BU on-delay timing relay s - 24 V AC DC - 1OC Characteristics on-delay timing relay - 0.05..1 s - 24 V AC DC - 1OC Main Commercial Status Range of product Product or component type Component name Time delay type Time delay range [Us] rated supply

More information

RM4TR32 three-phase network control relay RM4-T - range V

RM4TR32 three-phase network control relay RM4-T - range V Characteristics three-phase network control relay RM4-T - range 300..430 V Complementary [Us] rated supply voltage Control threshold undervoltage Control threshold overvoltage Output contacts Main Range

More information

TeSys protection components

TeSys protection components Description, characteristics -pole thermal overload relays, model d Description Model d -pole thermal overload relays are designed to protect a.c. circuits and motors against overloads, phase failure,

More information

LUMOTAST 75 keylock switch IP LUMOTAST 75 keylock switch IP40, round collar 1-45 LUMOTAST 75 keylock switch IP40, rectangular collar 1-46

LUMOTAST 75 keylock switch IP LUMOTAST 75 keylock switch IP40, round collar 1-45 LUMOTAST 75 keylock switch IP40, rectangular collar 1-46 TAST 75 IP40 General data TAST 75 IP40 pushbutton range Illuminated pushbuttons, signal lamps and keylock switches diameter 6.2 mm Degree of protection IP40 Solder terminals for the following wire cross-sections:

More information

SPA Pendant Control Station

SPA Pendant Control Station Tecno Elettrica Ravasi The NPA Pendant Station is a control device for all industrial machinery. It operates as an auxiliary controller of electrical motors through a power interface, such as a contactor

More information

RM4TU02 three-phase network control relay RM4-T - range V

RM4TU02 three-phase network control relay RM4-T - range V Characteristics three-phase network control relay RM4-T - range 300..430 V Complementary [Us] rated supply voltage Control threshold undervoltage Output contacts Main Range of product Product or component

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

RE7TP13BU adjustable on-delay timing relay s - 24 V AC DC - 2OC

RE7TP13BU adjustable on-delay timing relay s - 24 V AC DC - 2OC Characteristics adjustable on-delay timing relay - 0.05..1 s - 24 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay range

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

Control Buttons / Switches for Panel Mounting Series 8003

Control Buttons / Switches for Panel Mounting Series 8003 www.stahl.de > Different actuators pushbutton mushroom pushbutton mushroom stay-put button mushroom stay-put button with key lock key-operated button key-operated switch > 2 contact elements > Spring clamp

More information

The essential guide of Automation & Control. helping you easily select the right product

The essential guide of Automation & Control. helping you easily select the right product The essential guide of Automation & Control helping you easily select the right product 00 Contents Control and signalling units p Pushbuttons, switches and pilot lights Ø with plastic bezel, Harmony XB.../

More information

TeSys protection components Mini-VARIO and VARIO switch disconnectors. 4 Switch type. Selection guide. VpD 0 VpF 0. VpF 01 4/2

TeSys protection components Mini-VARIO and VARIO switch disconnectors. 4 Switch type. Selection guide. VpD 0 VpF 0. VpF 01 4/2 Selection guide TeSys protection components Mini-VARIO and VARIO switch disconnectors Applications Mini-Vario and Vario rotary switch disconnectors from to A are suitable for onload making and breaking

More information

Position switches FD series

Position switches FD series A Position switches FD series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fibber glass rod gasket sphere sphere 6 adjustable lever safety adjustable lever

More information

XCS Safety Interlock Specifications

XCS Safety Interlock Specifications XCS Safety Interlock Specifications General Characteristics (Metal, urret Head, ypes XCS-A, XCS-B, XCS-C, and XCS-E Plastic, Double Insulated, urret Head, ypes XCS-PA, XCS-A, XCS-PL, XCS-PR, XCS-L, XCS-R,

More information

Product info. Pilot devices Technical characteristics

Product info. Pilot devices Technical characteristics Product info Pilot devices Technical characteristics Climatic resistance: conform to IEC 60068-2-3 (constant humid heat) conform to IEC 60068-2-30 (cyclical damp heat) Degree of protection conform to IEC

More information

RE7ML11BU time delay relay 6 functions s - 24 V AC DC - 1OC

RE7ML11BU time delay relay 6 functions s - 24 V AC DC - 1OC Characteristics time delay relay 6 functions - 0.05..1 s - 24 V AC DC - 1OC Complementary Discrete output type Contacts material Width pitch dimension Voltage range Connections - terminals Tightening torque

More information

References Control and signalling units Ø 22 0

References Control and signalling units Ø 22 0 Merlin Gerin Modicon Square D Telemecanique References To combine with heads, see pages 36060-EN_ er4.0/2 to 36067-EN_er3.0/2 Body/contact assemblies - Screw clamp terminal connections 814264 Body/fixing

More information

RM4LG01M liquid level control relay RM4-L V AC

RM4LG01M liquid level control relay RM4-L V AC Characteristics liquid level control relay RM4-L - 220..240 V AC Complementary [Un] rated nominal voltage Operating voltage tolerance Width Output contacts Maximum electrode voltage Maximum electrode current

More information

RM4UA33F voltage measurement relay RM4-U - range V V AC

RM4UA33F voltage measurement relay RM4-U - range V V AC Characteristics voltage measurement relay RM4-U - range 30..500 V - 110..130 V AC Complementary [Us] rated supply voltage Output contacts Internal input resistance Permissible continuous overload Permissible

More information

Catalog February Control and Signaling Indicating Banks XVB Diameter 70mm

Catalog February Control and Signaling Indicating Banks XVB Diameter 70mm Catalog February 2004 Control and Signaling Indicating Banks XVB Diameter 70mm Presentation Indicating Banks and Beacons Ø70mm,typeXVB 7 XVB C6pp 7 XVB Cppp 9 XVB C081 8 XVB C9p 2 XVB Lppp 14 XVB C1p 1

More information

Contactor Types CI 61-98

Contactor Types CI 61-98 MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

Motor starters up to 150 A TeSys motor circuit-breakers, contactors and relays. Catalogue February

Motor starters up to 150 A TeSys motor circuit-breakers, contactors and relays. Catalogue February Motor starters up to 0 A TeSys motor circuit-breakers, contactors and relays Catalogue February 0 This international site allows you to access all the Telemecanique products in just clicks via comprehensive

More information

SIGUARD Safety Relays

SIGUARD Safety Relays Ordering Data: 3T8 21 3T8 22 3T8 23 3T8 2 3T8 25 3T8 27 3T8 28 3T8 30 3T8 3 + 3T8 35 Obtainable Width Enabling Signaling Category Operating Screw Terminal Cage Clamps mm Contacts Contacts Acc. to EN95-1

More information

ATS01N212QN soft starter for asynchronous motor - ATS01-12 A V KW

ATS01N212QN soft starter for asynchronous motor - ATS01-12 A V KW Characteristics soft starter for asynchronous motor - ATS01-12 A - 380..415V - 5.5 KW Complementary Assembly style Function available Power supply voltage limits Main Range of product Altistart 01 Product

More information

ABE7R16T330 sub-base - soldered electromechanical relays ABE7-16 channels - relay 12.5 mm

ABE7R16T330 sub-base - soldered electromechanical relays ABE7-16 channels - relay 12.5 mm Product datasheet Characteristics ABE7R16T330 sub-base - soldered electromechanical relays ABE7-16 channels - relay 12.5 mm Main Range of product Advantys Telefast ABE7 Product or component type Sub-base

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Control and Signaling Units

Control and Signaling Units Control and Signaling Table of Contents Page Specifications... 3 Constructions Characterisitics... 3 Ordering Guide... 4 Pushbutton... 5 Double Pushbutton... 6 Emergency (Mushroom Head)... 6 Selector...

More information

RM4JA32M current measurement relay RM4-J - range A V AC

RM4JA32M current measurement relay RM4-J - range A V AC Characteristics current measurement relay RM4-J - range 0.3..15 A - 220..240 V AC Complementary [Us] rated supply voltage Operating voltage tolerance Main Range of product Product or component type Relay

More information

EasyPact TVS control relays

EasyPact TVS control relays EasyPact TVS Motor starters, ors & relays up to 630 A CPB100424 CPB100425 CPB100426 Contact Coil V AC/Hz 50 Hz 50 Hz 50 Hz 24 CAE40B5 CAE22B5 CAE31B5 48 CAE40E5 CAE22E5 CAE31E5 110 CAE40F5 CAE22F5 CAE31F5

More information

Safety switches with lock and separate actuator

Safety switches with lock and separate actuator Safety switches with lock and separate Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF7 VF KEYF ACTUATORS CONTACT BLOCKS 1 2 21 22 2NO+1NC FD FP 2 29 33 34 2NC CONDUIT ENTRY Threaded conduit

More information

Low Voltage. EasyPact TVS. 4 Pole Contactors from 16A to 125A. Catalog 2014

Low Voltage. EasyPact TVS. 4 Pole Contactors from 16A to 125A. Catalog 2014 Low Voltage EasyPact TVS 4 Pole Contactors from 16A to 125A Catalog 2014 Schneider Electric TM Worldwide 24 billion sales in 2013 Schneider Electric TM in India* 19000+ Employees 43 % of sales in new economies

More information

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Complementary Contacts material Control type [Us] rated supply voltage Voltage range Main Range of product Product or component

More information

Selection diagram LED COLOUR CONNECTIONS FIXING 3/65

Selection diagram LED COLOUR CONNECTIONS FIXING 3/65 holders Selection diagram COLOUR 2 3 4 6 8 CONNECTIONS FIXING V clamping screws S weld on printed circuit P panel F base 3/65 holders code structure E2 LP1A3V1 Fixing P panel F base Type of connection

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

The specified data apply only if actuators/signal indicators are combined with contact blocks and lamp sockets within the same product range.

The specified data apply only if actuators/signal indicators are combined with contact blocks and lamp sockets within the same product range. General data control component range For a mounting hole diameter of. mm to IEC 60947 50V/6A max. Water-jet proof IP65 Contact blocks: Gold and silver contacts with quick-connect terminals.8 x 0.8 mm;

More information

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC Product data sheet Characteristics RE17RMMW time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Complementary Contacts material Control type Voltage range Main Range of product Product

More information

Pendant stations for small hoist application, in single / double row or direct power circuits switchings and tail lift controls.

Pendant stations for small hoist application, in single / double row or direct power circuits switchings and tail lift controls. Lifting equipment Contents Pendant stations for small hoist application, in single / double row or direct power circuits switchings and tail lift controls. page 12 to 25 Giovenzana International Company,

More information

Bulletin 700-CF Control Relay

Bulletin 700-CF Control Relay Bulletin 700-CF Control Bulletin 700 CF Control IEC industrial relays Mechanically linked contact performance per IEC 60947-5-1 Gold plated, bifurcated version for low level switching applications Master

More information

Limit Switches - Limit Type Metal Body IP66

Limit Switches - Limit Type Metal Body IP66 Limit Switches - Limit Type Metal Body IP66 High mechanical resistance Degree of protection IP66 Aluminium body Positive Opening Operation Minimum Actuation Force/Torque Minimum Force to achieve Positive

More information

02/11/2015

02/11/2015 DIN Rail Mount 35 mm HNM Part number 84870700 Control of one or two levels Filling or emptying function HNM : Control by a resistive level probe HNE : Control by a discrete sensor Part numbers Type Sensing

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 MAKING MODERN LIVING POSSIBLE Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other

More information

Zelio Relay - plug-in relays

Zelio Relay - plug-in relays Presentation or Presentation of the range The RXM miniature relay range comprises: A relays with C/O contacts, 0 A relays with C/O contacts, A relays with C/O contacts and A low level relays with C/O contacts.

More information

Datasheet - CSS P+D-E-L

Datasheet - CSS P+D-E-L Print - Create PDF - Create EXCEL file - Hide system components 05.03.2012-11:05:24h Datasheet - CSS 8-180-2P+D-E-L Safety sensors / CSS 180 Image Preferred typ (Minor differences between the printed image

More information

1 contact actuation position per direction. Page 5/ contact actuation position per direction _1. Page 5/124

1 contact actuation position per direction. Page 5/ contact actuation position per direction _1. Page 5/124 Presentation Osiswitch Classic For hoisting and mechanical handling applications, types XCR and XCK MR For conveyor belt shift monitoring, type XCR T b XCR v With head for rotary movement operators, spring

More information

Enclosed Switch. Ordering Information. Subminiature Enclosed Switch (Measuring 48 x 17.5 x 45 mm) with High Sealing Property. Approved Standards

Enclosed Switch. Ordering Information. Subminiature Enclosed Switch (Measuring 48 x 17.5 x 45 mm) with High Sealing Property. Approved Standards Enclosed Switch Subminiature Enclosed Switch (Measuring 48 x 17.5 x 45 mm) with High Sealing Property Built-in coil spring type basic switch housed in rigid zinc diecast alloy casting boasts long life

More information

30mm XN E-Stops. File No. E Non-illuminated: 25 to +60 C (no freezing), Illuminated: 25 to +55 C (no freezing) Operating Humidity

30mm XN E-Stops. File No. E Non-illuminated: 25 to +60 C (no freezing), Illuminated: 25 to +55 C (no freezing) Operating Humidity ø3mm - XN E-Stops Switches & Pilot Devices Circuit Breakers Terminal Blocks Contactors Timers elays & Sockets Signaling ights Switches & Pilot Devices Key features: Plastic bezel, metallic padlock and

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

EEx ed/emd pendant control stations

EEx ed/emd pendant control stations XAW-P Features The XAW-P range of Pendant control stations consists of several sizes from 2 to 16 ways. Booted operators (interchangeable) From 1 to 3 contacts per way Pilot light (with LED multivoltage,

More information

Model Number Structure

Model Number Structure Enclosed Switch SHL Subminiature Enclosed Switch (Measuring 48 x 17.5 x 45 mm) with High Sealing Property Built-in coil spring type basic switch housed in rigid zinc diecast alloy casting boasts long life

More information

Preventa Machine Safety Products

Preventa Machine Safety Products Preventa Machine Safety Products Catalog 2009 200 Supplement Safety Relay Modules 2 Contents Preventa safety relay modules Selection guide 2 Electrical Ratings 6 Types XPSAC and XPSAXE For Emergency stop

More information

Limit and Enclosed Switches Momentary Cable Pull Limit Switches: For Signaling Applications

Limit and Enclosed Switches Momentary Cable Pull Limit Switches: For Signaling Applications MOMENTARY (CONTACT SWITCH) OPERATING HEAD Momentary Cable Pull Limit Switches are designed for signaling applications; they are not to be used as emergency stop devices. (For emergency stop applications,

More information

Series L2. Switch Handle Assemblies K11. Rotary Cam Switches

Series L2. Switch Handle Assemblies K11. Rotary Cam Switches Series Switch Handle Assemblies Switch Handle Assembly Mounting Method Frame Size Catalog Number Price Switch Handle Assembly Mounting Method Frame Size Catalog Number Price Screw ➊➌ 48 x 48 LFS2-A-4-8.50

More information

The specified data apply only if actuators/signal indicators are combined with contact blocks and lamp sockets within the same product range.

The specified data apply only if actuators/signal indicators are combined with contact blocks and lamp sockets within the same product range. General data control component range For a mounting hole diameter of.3 mm to IEC 60947 Contact blocks with gold or silver contacts Depth behind panel only 9. mm Water-jet proof IP65 collar shapes The contact

More information

Series Panel Mounted Control Devices

Series Panel Mounted Control Devices Series Panel Mounted Control Devices CONTROL DEVICES Series Features: Suitable for hazardous and corrosive locations. Installation is easy and precise. Devices fit into a standard 30.5mm, 1.2" knock-out.

More information

Voltage monitoring relay CM-ESS.M for single-phase AC/DC voltages

Voltage monitoring relay CM-ESS.M for single-phase AC/DC voltages Data sheet Voltage monitoring relay CM-ESS.M for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

30mm XN E-Stops. File No. E68961

30mm XN E-Stops. File No. E68961 XN Series 3mm XN E-Stops Key features: Plastic bezel, metallic padlock and fl ush bezel available (XN series) Install up to 2 padlocks (XN4E) ø4, ø44 or ø6mm Mushroom heads available IDEC s original safe

More information

Pilot devices - Compact range

Pilot devices - Compact range Pilot lights/pilot lights with integrated LED Pilot light Ba 9s base, bulb not included 1SFC151092F0001 1SFC151093F0001 Color: Red CL-100R 1SFA 619 402 R1001 0.018 Green CL-100G 1SFA 619 402 R1002 0.018

More information

Lift Devices

Lift Devices 0 08 General Index Introduction 2 Presentation Products Index 4 Company Profile Switches for floor levelling operation - FR, FX series 14 Switches for floor levelling operation - FP series Switches with

More information