Pendant control stations 6

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Pendant control stations 6"

Transcription

1 Characteristics 6 Environment Conformity to standards EN/IEC EN/IEC 600-, UL 508, CSA C- n EN/IEC and EN/ISO 850 for versions with trigger action Emergency stop Product certifications Special version, with suffix H7 : UL Listed A600-Q600, CSA A600-Q600, CCC, GOST Protective treatment Standard version TH Ambient air temperature For operation C For storage C Vibration resistance 15 gn ( Hz) conforming to IEC Shock resistance 100 gn conforming to IEC Electric shock protection Class II conforming to IEC 610 Degree of protection IP 65 conforming to IEC 6059 IK 08 conforming to EN 5010 Mechanical durability 1 (in millions of operating cycles) Enclosure Double insulated polypropylene, coloured yellow throughout Cable entry Rubber sleeve with stepped entry diameter for cable Ø 8 Ø 6 mm Contact block characteristics Rated operational characteristics ZB BEppp, XEN Gpppp, XAC Spppp XEN Tpppp Thermal current (lthe) A 10 a AC-15: A600 or Ue = 600 V, le = 1. A or Ue = 0 V, Ie = 3 A c DC-: Q600 or Ue = 600 V, le = 0.1 A or Ue = 50 V, Ie = 0.7 A a AC-15: A300 or Ue = 0 V, le = 3 A c DC-: Q300 or Ue = 50 V, le = 0.7 A conforming to EN/IEC Appendix A Rated insulation voltage (Ui) ZB BEppp, XEN Gpppp, V 600, degree of pollution 3 XAC Spppp XEN Tpppp V 00, degree of pollution 3, conforming to EN/IEC Rated impulse withstand voltage (U imp) kv 6, conforming to EN/IEC Positive operation Mushroom head pushbutton: N/C contact with positive opening operation conforming to EN/IEC Appendix K Contact operation N/C or N/O slow break Resistance across terminals MΩ y 5 Operating force N Operators - with contact: 10 - with contact: 8 - with additional N/O contact: 5 - with additional N/C contact: 3 Terminal referencing Conforming to CENELEC EN 500 Short-circuit protection 10 A cartridge fuse type gg (gl) Connection mm Screw and captive cable clamp terminals. Clamping capacity: min. 1 x 0.5 mm, max., with or without cable end: x 1.5 mm or 1 x.5 mm. 6.3 mm clips (on request), please consult your Customer Care Centre. Operational power Conforming to EN/IEC Appendix C. Utilisation categories AC-15 and DC-. Operating rate: 3600 operating cycles/hour. Load factor: 0.5. a.c.supply a 50/60 Hz d.c. o Inductive circuit supply c Power broken in W for 1 million operating cycles Millions of operating cycles 1 0,6 0, 0, Ithe 30 V 7 V...8 V Voltage V 8 0 o W , Current in A References: page 30075/3 Dimensions: page 30075/ Application schemes: page 30075/15 Presentation: page 30075/ EN_Ver.3.indd

2 References 6 Complete stations ready for use DF56553 For control of single-speed motors Functions Number of operators Contact block(s) and scheme Reference Weight Per direction For Emergency stop XAC A XAC A71 XAC A81 XAC A DF5655 XAC A7 XAC A8 1 trigger action latching Emergency stop Ø 30 mm operator ZA BS8 (1) XAC A7 (1) XAC A8 (1) DF5655 N/C N/C XEN T9 XAC A71 (1) N/C N/C XEN T9 XAC A81 (1) XAC A71 XAC A81 (1) Trigger action latching Emergency stop pushbuttons conform to standards EN/IEC 600-, EN/ISO 850, Machinery directive 98/37/EC and standard EN/IEC EN_Ver.3.indd 3

3 References (continued) 6 Complete stations ready for use DF56555 For control of single-speed motors (continued) Functions Number of operators Contact block(s) and scheme Reference Weight Per direction For Emergency stop XAC A XAC A XAC A71 XAC A81 1 trigger action latching Emergency stop Ø 0 mm operator ZA BS8 (1) XAC A7 (1) XAC A8 (1) N/C N/C XEN T9 XAC A71 (1) XAC A7 XAC A8 XAC A71 XAC A N/C N/C XEN T9 XAC A81 (1) XAC A XAC A XAC A671 XAC A681 XAC A67 XAC A trigger action latching Emergency stop Ø 0 mm operator ZA BS8 (1) XAC A67 (1) 0.85 XAC A68 (1) (1) Trigger action latching Emergency stop pushbuttons conform to standards EN/IEC 600-, EN/ISO 850, Machinery directive 98/37/EC and standard EN/IEC Characteristics: page 30075/ Dimensions: page 30075/ Application schemes: page 30075/15 Presentation: page 30075/ EN_Ver.3.indd

4 References (continued) 6 Complete stations ready for use DF56556 DF56557 For control of single-speed motors (continued) Functions Number of operators 6 1 trigger action latching Emergency stop Ø 0 mm operator ZA BS8 (1) Contact block(s) and scheme Reference Weight Per direction For Emergency stop N/C N/C XEN T9 N/C N/C XEN T9 XAC A671 (1) XAC A681 (1) I O 8 on 7 operators and on the 8 th operator XAC A XAC A671 XAC A681 XAC A871 XAC A881 XAC A For control of -speed motors Functions Number of operators Contact block(s) and scheme Reference Weight Per direction For Emergency stop N/O N/O staggered XEN G91 XAC A XAC A91 XAC A9 XAC A91 1 trigger action latching Emergency stop Ø 30 mm operator ZA BS8 (1) N/O N/O staggered XEN G91 N/O N/O staggered XEN G91 N/C N/C XEN T9 XAC A9 (1) XAC A91 (1) (1) Trigger action latching Emergency stop pushbuttons conform to standards EN/IEC 600-, EN/ISO 850, Machinery directive 98/37/EC and standard EN/IEC EN_Ver.3.indd 5

5 References (continued) 6 Complete stations ready for use DF56558 For control of -speed motors (continued) Functions Number of operators Contact block(s) and scheme Reference Weight Per direction For Emergency stop N/O N/O staggered XEN G91 XAC A XAC A91 1 trigger action latching Emergency stop Ø 0 mm operator ZA BS8 (1) N/O N/O staggered XEN G91 N/O N/O staggered XEN G91 N/C N/C XEN T9 XAC A9 (1) XAC A91 (1) (a) (b) N/O N/O staggered (a) XEN G91 XAC A XAC A9 XAC A91 (b) DF56558 XAC A9 N/O N/O staggered (a) XEN G91 1 trigger action latching Emergency stop Ø 0 mm (b) operator ZA BS8 (1) XAC A9 (1) N/O N/O staggered (a) XEN G91 N/C N/C XEN T9 XAC A91 (1) (b) XAC A9 XAC A91 (1) Trigger action latching Emergency stop pushbuttons conform to standards EN/IEC 600-, EN/ISO 850, Machinery directive 98/37/EC and standard EN/IEC Characteristics: page 30075/ Dimensions: page 30075/ Application schemes: page 30075/15 Presentation: page 30075/ EN_Ver.3.indd

6 References 6 Empty enclosures 530 Empty enclosures Description Enclosure comprising: - the enclosure, - internal mounting plate, - protective cable sleeve, - internal cable clamp, - suspension ring, - cable tie (for tightening sleeve onto cable). Number of cut-outs Reference Weight XAC A XAC A03 (1) 0.0 XAC A0 XAC A XAC A05 (1) 0.65 XAC A03 6 XAC A XAC A XAC A Variable composition stations, factory assembled Use the order form on page 30075/17 to defi ne the required confi guration. Equipment: contact blocks, operating heads (control and signalling), complementary accessories See separate components, page 30075/8 (1) Enclosures with 3 cut-outs XAC A03 and 5 cut-outs XAC A05 cannot be fi tted with a mounting adaptor for base mounted units. The first cut-out can only be used for the Emergency stop function. XAC A EN_Ver.3.indd 7

7 References 6 Separate components and spare parts Contact blocks for front mounting Description Application Function Scheme Reference Weight Single block, spring return slow break Single-speed N/O p p N/C p p N/C N/O N/O simultaneous (1) XEN G speed N/C N/O N/O staggered (1) XEN G XEN G91 XEN G Double block, latching slow break () Single-speed N/O N/O XEN G XEN G3781 XEN G3791 XEN T9 N/O N/C Isolating switch, slow break, for front mounting For mounting in enclosures XAC A03 (frontal cut-out) XAC A05, A06, A08 (frontal or base cut-out) XEN G Application Function Scheme Reference Weight Emergency stop N/C N/C N/C XEN T with positive opening operation (1) Only for use with XAC A9ppp operators. () Not suitable for use with the following operating heads: ZA BB, ZA BD, ZA BG and ZA BS.. Characteristics: page 30075/ Dimensions: page 30075/ Application schemes: page 30075/15 Presentation: page 30075/ EN_Ver.3.indd

8 References (continued) 6 Separate components and spare parts 5300 Contact blocks for base mounting Description Function Scheme Reference Weight Spring return slow break (1) N/O XAC S XAC S10p N/C XAC S N/O N/O XAC S N/C N/C XAC S N/C N/O XAC S ZB BV006 Pilot light bodies for front mounting Description Supply voltage Scheme Reference Weight Direct supply Bulb not included () y 00 V X1 ZB BV X 530 Direct supply, through resistor Incandescent BA 9s base fi tting 0 V bulb included 30 V X1 ZB BV X ZB BV007 (1) Not suitable for use with 3-position operating heads ZA BD and ZA BG or for mounting in enclosures XAC A039 and XAC A03. () Bulb type for use with direct supply units: BA 9s base fi tting incandescent bulb U y 0 V or neon bulb 0 V y U y 00 V. Maximum power:.6 W, maximum Ø: mm, maximum length: 8 mm. See page EN/ EN_Ver.3.indd 9

9 References (continued) 6 Separate components and spare parts 5303 XAC A9pp Operating heads for front mounting Description Colour Sold in lots of Unit reference Weight Booted operators White 10 XAC A Black 10 XAC A Green 10 XAC A Red 10 XAC A Yellow 10 XAC A Blue 10 XAC A Brown 10 XAC A Operating heads for front or base mounting Description Colour Type Reference Weight Trigger action latching Red Ø 30 mm ZA BS Emergency stop (1) Turn to release Ø 0 mm ZA BS DF53893 ZA BS8 ZA BS9 Trigger action latching Emergency stop () Key release (n 55) Key withdrawal in rest (unactuated) position Selector switches (3), standard handle (Not to be used with XEN Gpppp contact blocks) Red Ø 30 mm ZA BS Ø 0 mm ZA BS Black position, stay put ZA BD position, stay put () ZA BD Key switches () (key n 55) Key withdrawal in left and right-hand position position, stay put ZA BG position, stay put () ZA BG5 0.0 ZA BDp Key switch () (key n 55) Key withdrawal in left-hand position position, stay put ZA BG ZA BGp Key switch () (key n 55) Spring return from right to left Key withdrawal in left-hand position Key switch () () (key n 55) Key withdrawal in centre position -position ZA BG position, stay put ZA BG3 0.0 DF56559 Wobblesticks (5) Operates in all directions for fast stop Black ZA BB Red ZA BB ZA BBp (1) Trigger action latching Emergency stop pushbuttons conform to standards EN/IEC 600-, EN/ISO 850, Machinery directive 98/37/EC and standard EN/IEC () Other key numbers available on request, please consult your Customer Care Centre. (3) Selector switches available with other mechanical functions, please consult your Customer Care Centre. () Only suitable for front mounting. (5) Base mounting recommended. Characteristics: page 30075/ Dimensions: page 30075/ Application schemes: page 30075/15 Presentation: page 30075/ EN_Ver.3.indd

10 References (continued) 6 Separate components and spare parts ZA BV0p 5300 Pilot light heads Description Colour Reference Weight For use with incandescent bulbs Lens cap with bezel and fixing nut White ZA BV Green ZA BV DL1 Cpppp DL1 CFppp Red ZA BV Yellow ZA BV Blue ZA BV DF5655 XAC A009 For use with neon bulbs Lens cap with bezel and fixing nut Clear ZA BV Green ZA BV Red ZA BV Yellow ZA BV Clear ZA BV XAC A960 DF ZB SZ3 Bulbs Description Voltage Sold in lots of Incandescent BA 9s base fi tting Maximum power:.6 W Maximum Ø: mm Maximum length: 8 mm Unit reference Weight 6 V 10 DL1 CB V 10 DL1 CE V 10 DL1 CE V 10 DL1 CE XAC B961 XAC A971 0 V 10 DL1 CE Neon BA 9s base fi tting Maximum power:.6 W Maximum Ø: mm Maximum length: 8 mm 0 V 10 DL1 CF V 10 DL1 CF V 10 DL1 CF XAC A98 XAC A Complementary accessories, tools Description Reference Weight Protective cable sleeve For cable Ø 8 to mm XAC A For cable Ø 8 to 6 mm XAC A Mechanical interlock for With fi xing screws XAC A operators Blanking plug With seal and fi xing nut ZB SZ Tightening tool for fi xing nut Adaptor for self-supporting cable type BBAP ZA BZ Mounted with protective sleeve for cable Ø 8 to 6 mm XAC B Lower support ring XAC A XBF X Protective guards for base mounted units For selector switch (standard handle) or Emergency stop head pushbutton For key switch or key release latching Emergency stop head pushbutton XAC A XAC A Bulb extractor For BA 9s base fi tting bulbs XBF X 0.05 ZA BZ EN_Ver.3.indd

11 References 6 Legends 30 x 0 mm with symbols conforming to NF E Function Symbol Reference Weight Function Symbol Reference Weight Raise, slow ZB BY Lower, slow ZB BY White bacround, black symbol Raise, fast ZB BY Lower, fast ZB BY Raise, slow-fast ZB BY Lower, slow-fast ZB BY Black bacround, white symbol 0 Red bacround, white symbol Right, slow ZB BY Left, slow ZB BY Right, fast ZB BY Left, fast ZB BY Right, slow-fast ZB BY Left, slow-fast ZB BY Forward, slow ZB BY Reverse, slow ZB BY Forward, fast ZB BY Reverse, fast ZB BY Forward, slow-fast ZB BY Reverse, slow-fast ZB BY Slew right, slow ZB BY Slew left, slow ZB BY Slew right, fast ZB BY Slew left, fast ZB BY Slew right, slow-fast ZB BY Slew left, slow-fast ZB BY Slow ZB BY Fast ZB BY Klaxon ZB BY Start-Klaxon ZB BY Start ZB BY Stop ZB BY Characteristics: page 30075/ Dimensions: page 30075/ Application schemes: page 30075/15 Presentation: page 30075/ EN_Ver.3.indd

12 References 6 Legends 30 x 0 mm 530 White Black Red Text Reference Weight b Start functions: white characters on black bacround b Stop functions: white characters on red bacround Text Reference Weight ZB BY01 Blank Black or red bacround ZB BY White or yellow bacround ZB BY Black White Yellow With English text With French text For pushbuttons For pushbuttons Start ZB BY Marche ZB BY Stop ZB BY Arrêt ZB BY Forward ZB BY Avant ZB BY Reverse ZB BY Arrière ZB BY ZB BY101 Up ZB BY Montée ZB BY Down ZB BY Descente ZB BY Right ZB BY Droite ZB BY Left ZB BY Gauche ZB BY On ZB BY En service ZB BY Off ZB BY Hors service ZB BY Power on ZB BY Sous tension ZB BY Slow ZB BY Lent ZB BY Fast ZB BY Vite ZB BY Klaxon ZB BY Klaxon ZB BY For selector switches For selector switches Arrêt-Marche ZB BY66 Off-On ZB BY Hors-en ZB BY With special texts b Specify text when ordering, b lines maximum, characters per line. White characters on black bacround White characters on red bacround Other versions ZB BY Black characters on white bacround ZB BY Black characters on yellow bacround Legends with texts in other languages. Please consult your Customer Care Centre. ZB BY ZB BY EN_Ver.3.indd

13 Dimensions 6 Dimensions XAC A pendant stations for control circuits internal Ø Number of operators b b c (1) For and 3-way XAC A stations. () For to 8-way XAC A stations. (3) With trigger action Emergency stop head operator. Protective guards XAC A98 XAC A Characteristics: page 30075/ Dimensions: page 30075/ Application schemes: page 30075/15 Presentation: page 30075/ EN_Ver.3.indd

14 Application schemes 6 Application schemes (typical examples) For control of single-speed reversing motor Contact blocks For control of -speed reversing motor contact blocks XEN G91 S1 S1 S S S S1 KM A1 KM1 A1 A A KM1 KM KM A A1 A A1 A A1 KM: high speed contactor EN_Ver.3.indd 15

15 Presentation 6 Variable composition stations, factory assembled EN_Ver.3.indd

16 Order form (specimen suitable for photocopying) 6 Variable composition stations, factory assembled Customer Schneider Electric Industries Company Order N Delivery date Sales offi ce - Subsidiary Co. Order N Enter the order with XAC A09 reference Unit reference of empty enclosure, see page 30075/7 Number of identical stations Enclosure price (1) XAC A 1 Legends see page 30075/ Contact blocks or pilot light bodies see page 30075/8 Operating heads or pilot light heads or blanking plug see page 30075/10 Reference Unit price Reference Unit price Reference Unit price Total price Unit mounted in base of enclosure (if required) (Except when using XAC A03 and XAC A05) Complementary accessories, see page 30075/ (cross the appropriate box or boxes) Description Reference Unit price Adaptor for self-supporting cable type BBAP for XAC B961 use with cable entry sleeve Ø 8 to 6 mm 15 Lower support ring XAC A Protective guard for selector switch (std. handle) or XAC A98 Emergency stop head pushbutton, mounted in base 17 Protective guard for key switch or key release XAC A983 Emergency stop head pushbutton, mounted in base Mechanical interlocking () Reference Quantity Unit price 17 XAC A009 Factory assembly: Number of heads or blanking plugs to be fi tted X Additional cost XAC 9VA for fi tting of 1 head or 1 blanking plug Total price of assembled pendant station (1) Obtain the empty enclosure price. () Connect with a line the ways which require mechanical interlocking. Examples: combinations possible Combinations not possible EN_Ver.3.indd 17

Pendant control stations 6

Pendant control stations 6 References Empty enclosures 0 XACA0 Empty enclosures Description Enclosure comprising: - the enclosure, - internal mounting plate, - protective cable sleeve, - internal cable clamp, - suspension ring,

More information

Safety dialogue solutions

Safety dialogue solutions General Presentation Emergency stop trip wire switches Emergency stop trip wire switches are designed to: b avert hazards (dangerous phenomena) at the earliest possible moment, or to reduce risks which

More information

K1H014MLH cam ammeter switch - 4 circuits A - screw mounting

K1H014MLH cam ammeter switch - 4 circuits A - screw mounting Characteristics cam ammeter switch - 4 circuits - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing

More information

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

Limit switches 5. Osiswitch Classic. Page 5/80. Page 5/80. Page 5/82. Page 5/82

Limit switches 5. Osiswitch Classic. Page 5/80. Page 5/80. Page 5/82. Page 5/82 Presentation, general characteristics switches Metal, type XCK J Conforming to CENELEC EN 41 b XCK J fixed body with 1 cable entry v With head for linear movement (plunger) Page /8 v With head for rotary

More information

Safety detection solutions

Safety detection solutions Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 01 A1 08 02 A2 A4 05 A5 external rubber gasket external rubber gasket external rubber gasket external rubber gasket external rubber gasket 21 25 4 69 5 stainless

More information

Catalog April Cam switches Complete products 10 A

Catalog April Cam switches Complete products 10 A Catalog April Cam switches Complete products A General Cam switches Complete products A The range of K cam switches ( A rating) comprises only complete switches. These products are more specifically designed

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Schneider Electric. TeSys Vacuum Contactors. June. Building a New Electric World

Schneider Electric. TeSys Vacuum Contactors. June. Building a New Electric World TeSys Vacuum Contactors June 2002 Building a New Electric World Selection guide, characteristics Contactors 5 Selection guide Contactor size LC1-V160 LC1-V320 LC1-V610 For utilisation category AC-3 Maximum

More information

RM4TR32 three-phase network control relay RM4-T - range V

RM4TR32 three-phase network control relay RM4-T - range V Characteristics three-phase network control relay RM4-T - range 300..430 V Complementary [Us] rated supply voltage Control threshold undervoltage Control threshold overvoltage Output contacts Main Range

More information

RE7TL11BU on-delay timing relay s - 24 V AC DC - 1OC

RE7TL11BU on-delay timing relay s - 24 V AC DC - 1OC Characteristics on-delay timing relay - 0.05..1 s - 24 V AC DC - 1OC Main Commercial Status Range of product Product or component type Component name Time delay type Time delay range [Us] rated supply

More information

3 - Cam switches. Contents 0. Complete switches, 10 A. Complete switches, 12 and 20 A. Adaptable sub-assemblies, 12 and 20 A

3 - Cam switches. Contents 0. Complete switches, 10 A. Complete switches, 12 and 20 A. Adaptable sub-assemblies, 12 and 20 A Contents - Cam switches Selection guide............................................. page / Complete switches, A b Front mounting by Ø or Ø mm, with x mm front plate... page / v Switches and stepping switches..............................

More information

RM17UAS. Main. Product or component type. Product specific application. Relay monitored parameters

RM17UAS. Main. Product or component type. Product specific application. Relay monitored parameters Characteristics voltage control relay RM17-U - range 65..260 V AC Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main Range of

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

TeSys protection components Mini-VARIO and VARIO switch disconnectors. 4 Switch type. Selection guide. VpD 0 VpF 0. VpF 01 4/2

TeSys protection components Mini-VARIO and VARIO switch disconnectors. 4 Switch type. Selection guide. VpD 0 VpF 0. VpF 01 4/2 Selection guide TeSys protection components Mini-VARIO and VARIO switch disconnectors Applications Mini-Vario and Vario rotary switch disconnectors from to A are suitable for onload making and breaking

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

References Control and signalling units Ø 22 0

References Control and signalling units Ø 22 0 Merlin Gerin Modicon Square D Telemecanique References To combine with heads, see pages 36060-EN_ er4.0/2 to 36067-EN_er3.0/2 Body/contact assemblies - Screw clamp terminal connections 814264 Body/fixing

More information

Control and Signaling Units

Control and Signaling Units Control and Signaling Table of Contents Page Specifications... 3 Constructions Characterisitics... 3 Ordering Guide... 4 Pushbutton... 5 Double Pushbutton... 6 Emergency (Mushroom Head)... 6 Selector...

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

Preventa Machine Safety Products

Preventa Machine Safety Products Preventa Machine Safety Products Catalog 2009 200 Supplement Safety Relay Modules 2 Contents Preventa safety relay modules Selection guide 2 Electrical Ratings 6 Types XPSAC and XPSAXE For Emergency stop

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

8 Installation Equipment

8 Installation Equipment 8 Installation Equipment SolConeX Series 8570, 8571 CES Series 8575, 8579, 8581 10342E00 The plug and sockets Series SolConeX and CES comply with IEC/EN 60 309-1/-2 (CEE) and European standards EN 50 014,

More information

9 Control Equipment. Control Button Series 8082

9 Control Equipment. Control Button Series 8082 9 Control Equipment Control Button 01706E00 contact elements enable contact blocks to be combined easily; using an actuator in the 8602 series, regardless of the type of actuator, up to 4 contact elements

More information

Electronic timer CT-TGD.12

Electronic timer CT-TGD.12 2CDC 251 098 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection

More information

AZM /11ZPKE 24 VAC/DC

AZM /11ZPKE 24 VAC/DC Print - Create PDF - Create EXCEL file - Hide system components 21.04.2011-14:12:20h Datasheet - AZM 415-11/11ZPKE 24 VAC/DC Solenoid interlock / AZM 415 Metal enclosure Interlock with protection against

More information

Zelio Relay - plug-in relays

Zelio Relay - plug-in relays Presentation or Presentation of the range The RXM miniature relay range comprises: A relays with C/O contacts, 0 A relays with C/O contacts, A relays with C/O contacts and A low level relays with C/O contacts.

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

n Choice of equipment SP 58 Index of protection: IP 2X - IP 2XC - under front plate

n Choice of equipment SP 58 Index of protection: IP 2X - IP 2XC - under front plate SP fuse carriers with protected terminals SP fuse carriers with protected terminals www.klinkmann.com n Choice of equipment Maximum cartridge rating Type Rated current 400 V± 0 V± 690 V± gg am gg am gg

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

General 1-2-Opto-electronics Safety Switches 4-Emergency

General 1-2-Opto-electronics Safety Switches 4-Emergency General 1-2-Opto-electronics Safety Switches 4-Emergency Logic Power The Lifeline 4 cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a

More information

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry. y HS5D First in the Industry Miniature Interlock Switches First in the Industry Head Removal Detection Function for Safer Performance (*based on IDEC research, July 09) New Generation Miniature Interlock

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Cam switches. CQ Series

Cam switches. CQ Series Cam switches CQ Series CQ Series Overview The range of cam switches CQ series includes ratings from to A with insulation voltage of 69V. According to the latest industrial application standards, CQ series

More information

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color) Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Enabling Switches. Safety. For more information on this product family, visit our website. Additional resources include:

Enabling Switches. Safety.  For more information on this product family, visit our website. Additional resources include: Safety For more information on this product family, visit our website. Additional resources include: New and updated product information Downloadable software demos & upgrades Part confi guration tool

More information

PHOENIX CONTACT

PHOENIX CONTACT Thermomagnetic circuit breakers CLIPLINE Data sheet 103943_en_04 PHOENIX CONTACT 2010-08-18 1 Description The UT 6-TMC M circuit breaker is a single-position overload circuit breaker with thermomagnetic

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

PR ONE cam switch Series Ready switch configurations matching your requirements. Our commitment makes the difference >

PR ONE cam switch Series Ready switch configurations matching your requirements. Our commitment makes the difference > R ONE cam switch Series Ready switch configurations matching your requirements Our commitment makes the difference R ONE cam switch Series A selection of standard switching programmes and mounting forms

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Technical catalogue. Modular DIN rail components Installation contactors

Technical catalogue. Modular DIN rail components Installation contactors Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a

More information

I E D C E R T. Net MA N A G E ME N T S Y S T E M ISO 9001: 2000 9105.RAVI. Pendant Stations LADY Series

I E D C E R T. Net MA N A G E ME N T S Y S T E M ISO 9001: 2000 9105.RAVI. Pendant Stations LADY Series C E R T I F MA N A G E ME N T I E D Net ISO 9001: 2000 9105.RAVI I S Y S T E M Pendant Stations LADY Series 4.1 Pendant Stations LADY Series - LA type single-row Main Features The new LADY series single-row

More information

SB 175 Connectors - up to 280 Amps

SB 175 Connectors - up to 280 Amps Connectors - up to 280 Amps 2 Pole Wires sizes from #12 (3.3 mm²) to 1/0 (50 mm²) fit in the second to largest connector in the SB series. The 3 pole adds an additional position for power or grounding.

More information

Zelio RXG interface relay

Zelio RXG interface relay Zelio RXG interface relay Essentials All-in-1 Document 2014 1 Presentation Zelio RXG presentation Zelio RXG interface relay is widely used in PLC interface application, for its reliable installation, easy

More information

Rotary cam switches GX series Planet-SWITCH Planet-DIN Planet-LOGIC

Rotary cam switches GX series Planet-SWITCH Planet-DIN Planet-LOGIC Rotary cam switches GX series Planet-SWITCH Planet-DIN Planet-LOGIC % electricity Rotary cam switches GX series Compact and finger safe (IP2 protection of contacts). Designed according to the latest technology

More information

>PR ONE CAM SWITCH SERIES. A selection of standard switch configurations ready for your requirements. Our commitment makes the difference >

>PR ONE CAM SWITCH SERIES. A selection of standard switch configurations ready for your requirements. Our commitment makes the difference > >R ONE CAM SWITCH SERIES A selection of standard switch configurations ready for your requirements Our commitment makes the difference > R ONE cam switch Series A selection of standard switch functions

More information

D-Line Contactors, Overload Relays and Accessories

D-Line Contactors, Overload Relays and Accessories D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................

More information

CI-TI Contactors and motor starters Types CI 6-50

CI-TI Contactors and motor starters Types CI 6-50 MAKING MODERN LIVING POSSIBLE Data sheet CI-TI Contactors and motor starters s CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other

More information

Cam switches. CQ Series

Cam switches. CQ Series Cam switches CQ Series CQ Series Overview The range of cam switches CQ series includes ratings from to A with insulation voltage of 69V. According to the latest industrial application standards, CQ series

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

Mureva Assembly surface mounted wiring devices

Mureva Assembly surface mounted wiring devices 1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label

More information

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data. Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated

More information

Electronic timer CT-VWE Impulse-ON with 1 c/o (SPDT) contact

Electronic timer CT-VWE Impulse-ON with 1 c/o (SPDT) contact Data sheet Electronic timer CT-VWE Impulse-ON with 1 c/o (SPDT) contact The CT-VWE is an electronic time relay with Impulse-ON function. It is from the CT-E range. The CT-E range is the economic range

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

400 Series Buccaneer BUCCANEER POWER. bulgin

400 Series Buccaneer BUCCANEER POWER. bulgin bulgin BUCCANEER FOR POWER Contact Retainer Sealing Gasket O Ring Contacts Locking Ring Retaining Nut Panel Body Contacts Contact Carrier O Ring Main Body Cable Gland Collet Gland Nut Sealed to IP68 when

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Catalog. Modular DIN rail components Installation contactors

Catalog. Modular DIN rail components Installation contactors Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

Motor circuit-breakers

Motor circuit-breakers Thermal-magnetic motor circuit-breakers type GV2-M GV2-M Thermal-magnetic motor circuit-breakers GV2-M Pushbutton control Standard power ratings Setting Magnetic Thermal Reference Weight of 3-phase motors

More information

Thermal Circuit Breaker / Switch Series 3131

Thermal Circuit Breaker / Switch Series 3131 Description Combination of single pole circuit breaker and N/FF switch with soft-touch rocker actuation. Contoured rockers are available with a choice of colours and legends, with optional illumination.

More information

INDUSTRIAL CONTROLS. APEM, PO BOX 8288, HAVERHILL, MA USA 01835-0788 TOLL FREE: (877) 246-7890 FAX: (781) 245-4531 E-mail: info@apem.

INDUSTRIAL CONTROLS. APEM, PO BOX 8288, HAVERHILL, MA USA 01835-0788 TOLL FREE: (877) 246-7890 FAX: (781) 245-4531 E-mail: info@apem. INDUSTRIAL CONTROLS INDUSTRIAL CONTROLS E INDUSTRIAL CONTROLS SELECTION GUIDE Series Description Page A01 & A02 Products & Features 2 A01 & A02 Specifications 3 A01 Illuminated or non-illuminated pushbutton

More information

Measuring and monitoring relays CM-MSS (4), CM-MSS (5) Thermistor motor protection relays

Measuring and monitoring relays CM-MSS (4), CM-MSS (5) Thermistor motor protection relays Data sheet Measuring and monitoring relays CM-MSS (4), Thermistor motor protection relays The devices CM-MSS (4) and (5) are used to monitor the overload of motors by the wiring temperature. The motors

More information

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide - long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

ILLUMINATION OPTIONS PANEL & C. 3.0max. page 66. page 66. page 66. page 66 0.8-1.6. page 66 0.8-3.0. page 66

ILLUMINATION OPTIONS PANEL & C. 3.0max. page 66. page 66. page 66. page 66 0.8-1.6. page 66 0.8-3.0. page 66 Colours and voltages: Neon Available with Red, Amber, Green or Clear lenses 00/30V (marked 0V), 200/250V (marked 230V) ED - Red, Yellow, Green, Blue, hite /2.2V Resistors for other voltages available.

More information

IEC Connectors. Introduction

IEC Connectors. Introduction Introduction IEC Connectors A full range of quality mains rated inlets, outlets and connectors conforming to IEC and EN 60320 specifications carrying UL, CSA, VDE and other approvals. With electrical ratings

More information

Electronic Circuit Breaker ESS20-0...

Electronic Circuit Breaker ESS20-0... Description Electronic circuit breaker type ESS0-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,

More information

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia. Pushbutton Switch (Cylindrical 10.5-dia.) CSM DS_E_4_4 Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment Momentary operation and lock. available in six colors.

More information

SWITCHGEAR. 4G cam switches

SWITCHGEAR. 4G cam switches SWITCHGEAR 164 4G cam switches ENERGY SAFELY SWITCHED 165 SWITCHGEAR 166 GENERAL INFORMATION 4G-series cam switches are low voltage switches, designed according to the latest knowledge about switchgear

More information

5,5 5,5 20-1 HKM11V HKM11X K1W12D01MC... LA1W12W. 01 1 0,32 5,5 5,5 20 1 - - HKM.. K1W12D10MC... LA1W12W. 10 1 0,32

5,5 5,5 20-1 HKM11V HKM11X K1W12D01MC... LA1W12W. 01 1 0,32 5,5 5,5 20 1 - - HKM.. K1W12D10MC... LA1W12W. 10 1 0,32 Mini Reversing Contactors, Mechanical Interlocked AC Operated Power Ratings Rated Aux. Contacts 2) Type Coil voltage 1) Current Built-in Additional 24 24V 50/60Hz 0 AC2, AC3 on left on right 230 220-230V

More information

Low Voltage Switchgear

Low Voltage Switchgear Low Voltage Switchgear Index Contents: Contactors K03, K07 Mini Contactors 2 BR6 Thermal overload relay 8 KNL6 - KNL30 Contactors 10 BR16, BR30 Thermal overload relay 17 KNL6G - KNL30G Contactors 19 KNL43,

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Switches & Pilot Devices

Switches & Pilot Devices Key features: 21/4 (8mm) round mounting hole Compact Design Saves Space Bright and Vivid Illumination Choice of Shapes and Functions old Clad Silver Contacts for reliable low level switching Snap action

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Class 525/580 CONTENTS Description Page General characteristics............................................... 1 Circuit breaker......................................................

More information

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Characteristics XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Complementary Detection system Kit composition [EAA] effective aperture angle Emission Main Range of product Product or

More information

Control Stations & Switches: Control Stations Flameproof D Series: Aluminum Control Stations

Control Stations & Switches: Control Stations Flameproof D Series: Aluminum Control Stations D Series: Aluminum Control Stations 1 Function 2 Functions 2 Functions 3 Functions Compliance Data: ATEX - IEC: Zone 1 & 2 21 & 22 ATEX IEC CE Ex d IIB / Ex d IIC T6 to T5 Ex td A21 T95 C IP66 IK10 Operating

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Switches and Indicators. Swisstac

Switches and Indicators. Swisstac Switches and Indicators Switches and Indicators Index Series Description Page 583 Product Assembly Page 584 Mounting Instruction Page 585 Product Range - pushbuttons for standard mounting - pushbuttons

More information

Safe switching and monitoring Solenoid Interlocks

Safe switching and monitoring Solenoid Interlocks Safe switching and monitoring Solenoid Interlocks Solenoid locking switches are used on sliding, hinged and removable guard doors that must be closed and locked for operator safety. It is a two part system

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

Technicaldata General

Technicaldata General Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle

More information