Data Center Energy: Going Forward. Vic Smith, Dell Jim Smith, Digital Realty Trust Representatives of The Green Grid

Size: px
Start display at page:

Download "Data Center Energy: Going Forward. Vic Smith, Dell Jim Smith, Digital Realty Trust Representatives of The Green Grid"

Transcription

1 Data Center Energy: Going Forward Vic Smith, Dell Jim Smith, Digital Realty Trust Representatives of The Green Grid

2 Agenda Introduction Data Center Energy Issues Business Considerations The Green Grid Overview The Green Grid Technical Deliverables Data Center Productivity Baseline Efficiency Market Study Organizational Barriers Data Center Rating Systems Power and Cooling Strategies Peer Review of LBNL Study on Direct Current in the Data Center Your Energy Action Checklist 2

3 Data Center Energy Issues Data center efficiency and productivity - costs Global environmental impacts Future IT growth and requirements Measurement of total data center energy consumption Best practices, new techniques, technologies and metrics Requirements, standards for increased efficiency and productivity 3

4 Data Center Energy Issues Data center efficiency and productivity - costs Global environmental impacts Future IT growth and requirements Measurement of total data center energy consumption Best practices, new techniques, technologies and metrics Requirements, standards for increased efficiency and productivity 4

5 Data Center Energy Issues Data center efficiency and productivity - costs Global environmental impacts Future IT growth and requirements Measurement of total data center energy consumption Best practices, new techniques, technologies and metrics Requirements, standards for increased efficiency and productivity 5

6 Why Do Data Centers Exist? 6 Data centers are used to vastly improve quality of life Health care & life sciences research Climate & weather research and analysis National security And perform many dimensions of useful work Reliable storage, distribution, & manipulation of data Efficient alternative to previous work methods Cost effective global business & communications And... Today, it takes less than half the energy to produce a dollar of economic output as it did in 1970 Information & communication technologies have played a critical role in reducing energy waste from sensors & microprocessors, to smart grids & virtualization Information and Communication Technologies: The Power of Productivity, ACEEE Report #E081, Feb. 2008

7 Primary Components of a Data Center What Consumes the Energy? Facility architectures Power distribution Cooling architectures Server populations Network infrastructure Data storage systems Operating system and application software 7

8 Where Does the Power Go? IT equipment ± 57% Cooling equipment ± 34% Power distribution losses ± 7% Lighting / other ± 2% Individual data centers can vary substantially. 8

9 Drivers of Energy Consumption More IT applications. More data. More servers. More storage. More energy demand. More density and hotter components in less space leads to... Increased energy and cooling demand leads to... Decreased energy availability-facilities maxed out leads to... Push for new, and costly, data center facilities / construction And mounting boardroom pressures to go green 9

10 Balancing Business Considerations Reduction of energy waste must account for: Overall impact on the economy Data center service and performance needs Uptime requirements Compute capability Scalability Business continuity Global standards and individual business impacts 10

11 Targets for Energy and Cost Savings 11 Improvements in component technology Improvements in server, storage and network technologies Increased use of virtualization Increased best practices understanding and adherence Savings in capital costs and data center build-out

12 The Green Grid A global consortium dedicated to advancing energy efficiency for data centers and business computing ecosystems by: Defining meaningful, user-centric models and metrics Developing standards, measurement methods, best practices and technologies to improve performance against the defined metrics Promoting the adoption of energy efficient standards, processes, measurements and technologies 12

13 Who s In The Green Grid? Board of Director Member Companies 13

14 Contributor Members 1E ADP Avocent Brocade Communications Systems BT plc Chatsworth Products, Inc. Cisco COPAN Systems Delta Products Corporation Digital Realty Trust Eaton EMC Emerson Network Power Enterprise-Rent-A-Car Fujitsu Siemens Computers GmbH Greene Engineers Novell PG&E Pillar Data Systems Qimonda QLogic Rackspace Saft Power Systems Inc. SatCon Stationary Power Systems SunGard Data Systems Symantec Corporation Teradata Texas Instruments The Uptime Institute Trane Verari Systems, Inc. Verdiem Vette Corp Western Digital ZT Group Int'l Inc

15 General Members 365 Main 3M 42U Active Power ADC Afco Systems Affiniti Alfa Tech Cambridge Allstate Alpikom SpA Angstrom Microsystems Aperture Technologies Avnet Technology Solutions Azul Systems Betfair Limited BigFix, Inc Blackwave Inc Bloomberg LP Broadcom Corporation BULL SAS Cassatt Corporation Cherokee International Ciena Corporation Coldwatt Inc. Compellent Technologies Corning Cable Systems CRAY INC Data Domain, Inc. Degree Controls, Inc Devon IT Dot Hill Systems Corp EBSCO Publishing EDS EqualLogic, Inc Evoswitch Netherlands B.V. Exelon Corporation Force10 Networks Forsythe Solutions Group, Inc GE Consumer & Industrial GlassHouse Technologies (UK) Green Data Systems Hifn, Inc. Host Europe GmbH Infinity SDC Limited Internet Initiative Japan Inc. Interxion Intransa, Inc. ITOCHU Techno-Solutions Corporation Juniper Networks Keysource Ltd Lee Technologies Lockheed Martin Corp Logicalis UK Limited LSI Mandragore Micron Technology, Inc. National Semiconductor NaviSite Inc. Neoware, Inc. Netezza Network Appliance NetXen Inc News Corporation Nexsan Technologies nscglobal Ltd. NTT America, Inc NTT COMWARE Corporation NTT DATA CORPORATION ONStor Inc Ortronics OSI soft, Inc. Panduit Corp Platform Computing PowerFile Quantum Corporation Quantum Energy Services & Technologies, Inc. RACKWISERampRate Sourcing Advisors Raritan, Inc. RipCode, Inc. Rittal Corporation Rothstein Kass S & C Electric Company Savvis Seagate Technology Sepaton Server Technology Inc ServerVault Corp SGI Siemens Corporate Research SingleHop, Inc SmartBunker SoftLayer Source IT Energy Spectra Logic Storwize Inc Synapsense Syska Hennessy TA Migration Solutions LTD Telvent Terremark Worldwide, Inc. The 451 Group Total Site Solutions Tretecnic Pty Ltd University of California, San Diego UTC Power Vossel Solution Wright Line LLC Xyratex

16 The Green Grid Membership Membership Growth Jan Feb Mar Apr May Jun Jul Aug Sept Oct Nov Dec Jan Over 150 members since February

17 Industry Cooperation and Coordination Energy efficiency and productivity metrics Real-time measurement protocols Data collection standards Assessment of industry-wide energy consumption and trends Potential new technologies and data center architectures

18 The Green Grid Initiatives: Creating a framework for best practices Create shared definitions, benchmarks and metrics to enable real-time measurement monitoring and control of data center efficiency and productivity Create baseline 'state-of-the-industry' documentation including benchmark architectures and a repository of data center efficiency knowledge Create a comprehensive technology roadmap for future data center design to maximize efficient and productive operations Assess new and alternate data center technologies Monitor progress on all fronts and provide periodic updates 18

19 The Green Grid Technical Work Groups 19 Data Collection and Analysis Focuses on investigations and analysis into the data center efficiency problem map EMEA Data Collection and Analysis Focuses on investigations and analysis into the data center efficiency problem map specifically for the EMEA region Data Center Technology and Strategy Focuses on existing and emergent technologies for data center efficiency Data Center Operations Focuses on use models, operational strategies, best practices and equipment standards Data Center Metrics and Measurements Focuses on data center characteristics, performance metrics, and measurement protocols for data collection

20 Why Are Metrics Important? Awareness If you can t measure it, you can t improve it Benchmarking Improving operations continuous improvement Comparing across the industry company to company Improvement over time generation to generation Technology validate claims Resulting in Better efficiency Better total cost of ownership

21 Why DCP? DCiE works well for assisting in optimizing power consumption of infrastructure equipment To address both infrastructure and IT productivity needs, we need one or more metrics to complement PUE/DCiE Infrastructure Equipment IT Equipment PUE/DCiE DCP

22 Data Center Productivity What is Data Center Productivity (DCP)? Methodology for quantifying the useful work that a data center produces relative to the quantity of any resource that it consumes to produce this work Mathematically expressed: DCP = Useful Work Produced by Data Center Resource Consumed Producing the Work Useful work is defined as completed tasks that have value to the end user or business supported by the data center 22

23 Baseline Efficiency Market Study Study Overview Interviewed data center facility operators and IT managers via phone Questions focused on drivers for and obstacles to energy efficiency in the data center Data Centers Profiled: 25 23

24 Baseline Efficiency Market Study Study Findings Drivers for Action The strongest motivation for increasing energy efficiency in data centers is to relieve constraints on increased IT capacity Interest in environmental sustainability at a corporate level is a driver for more efficient management of data centers Obstacles to Action Risk aversion and fear of downtime is slowing adoption of best practices (e.g., as enabling server power management features) IT professionals don t typically have strong incentives to invest in reducing energy consumption beyond the extent to which it lets them install more equipment 24

25 Baseline Efficiency Market Study Study Findings (continued) Positive Trends The Green Grid s first Data Center metrics, PUE and DCiE, are in use and gaining recognition Virtualization is a broadly-implemented strategy for improving energy efficiency Opportunities Data center managers want industry-standard instrumentation and tools for monitoring, trend analysis & capacity planning and benchmarking Data center energy management is an area of new expertise and opportunity for data center professionals 25

26 Addressing Organizational Barriers to Managing Efficiency 26 Organizational Challenges Many businesses operate independent IT and Facilities departments which are motivated by different goals/interests IT typically buys IT equipment while Facilities foots the energy bill Data center energy consumption is often ignored and not included in the TCO calculations IT refresh cycles are 2-5 years with rising power and cooling loads while Facilities are designed for years There are a number of external influences as well including legislation, sustainability initiatives, availability and cost of energy M Data Center Power Meters M M M M M M M M M M M M M M M M M M M M M M M M M M Utility Meter M Facility Meters M IT Meters

27 Addressing Organizational Barriers to Managing Efficiency Recommendations Energy efficiency needs to be driven from the CEO down in an organization Need to integrate independent monitoring systems (IT, Facilities, Utilities) into actionable knowledge Goals and incentives need to be aligned between IT and Facilities to optimize energy efficiency while meeting the business objectives Design team, operations and supply chain include energy efficiency in TCO calculations Utilize energy efficient IT and Facility components and systems to measure, monitor and provide auditable data for corporate sustainability initiatives Incorporate The Green Grid processes 27

28 Data Center Rating Systems The Green Grid exploring the creation of a data center rating system Instrument a data center for measuring DCiE or PUE Better DCiE and PUE scores receive higher ratings Track long term data center energy use EPA ENERGY STAR U.S. government energy management program providing proven solutions to help public and private sector building owners and managers reduce their energy consumption Developing the ENERGY STAR Rating for Data Center Infrastructure Rating Green Grid Recognized Green Grid Bronze Green Grid Silver Green Grid Gold Green Grid Platinum Data Center Requirements 1. Implement DCiE measurement methodologies 2. Report data center type (i.e. Tier I, II, III, IV data center) 3. Report the elapsed time of the Assessment Period 4. Report the Mean Source Load for the Assessment Period 5. Report a Mean DCiE score 40% 6. Report the Highest Daily DCiE score occurring during the Assessment Period 7. Report the Lowest Daily DCiE score occurring during the Assessment Period Recognized requirements plus: Report a Mean DCiE score 50% minus Bronze Adjustments Recognized requirements plus: Report a Mean DCiE score 60% minus Silver Adjustments Recognized requirements plus: Report a Mean DCiE score 70% minus Gold Adjustments Recognized requirements plus: Report a Mean DCiE score 80% minus Platinum Adjustments 28

29 Data Center Rating Systems European Union Code of Conduct Metrics as a tool for data center owners, operators and users Target for energy efficiency improvements by data center, depending on data center types, etc. New EU Code of Conduct for data centers in 2008 Department of Energy Save Energy Now Assessment DOE conducts plant energy assessments to help manufacturing facilities across the nation identify immediate opportunities to save energy and money Focuses on energy-intensive systems, including process heating, steam, pumps, fans and compressed air SVLG Energy Efficient DCDP and Data Centers EPC Clean & Green Energy Action Plan Developing environmental performance criteria for data centers Collaborating with CEC, LBNL, PG&E and SVP Follow LEED Version

30 Data Center Rating Systems The Green Grid s Role in Data Center Rating Systems Goal: Reconcile the approaches of the various industry bodies and governmental organizations to provide one, unified voice to the industry The Green Grid will achieve this by: Working with policy-makers across continents including the US EPA and DOE as well as with the European Union Basing systems off of a common set of metrics such as DCiE/PUE to start Creating data center performance data bases Converging on common assessment tools, where possible Opening up cross-continental lines of communication 30

31 5 Ways To Save Server Power 1. Identify the culprits 2. Enable server processor power saving features 3. Right-size server farms 4. Power down servers when not in use 5. Decommission old systems that provide no useful work The figure illustrates a model where server power consumption scales linearly with CPU utilization. 31

32 7 Cooling Strategies 1. Develop an air management strategy 2. Move cooling closer to the load 3. Operate at a higher delta-t 4. Install economizers 5. Utilize higher specification and performance equipment 6. Utilize dynamic controls 7. Maintain higher operating temperatures The figure provides an example of an enhanced multi-airflow design. 32

33 Peer Review of LBNL Study on Direct Current in the Data Center 33 In Jan. 2007, LBNL posted the results of their demonstration project studying 380Vdc power in the data center The Green Grid peer-reviewed the study to Provide additional, relevant facts to allow any data center owner to make an analysis on what is best for their future Clarify the 5-7% energy savings gain posted by LBNL should be the relevant discussion, not the 28% compared to a typical AC system Summary LBNL and its partners successfully completed a demonstration of 380Vdc power 380Vdc power can make a difference in certain applications Challenges remain before this will be commercially viable Be knowledgeable of all the architectures available to choose the one best for your needs

34 Your Energy Action Checklist Conduct accurate assessments of energy use Validate assumptions and monitor consumption to assess opportunities and risks Systematically address individual data center efficiency issues Minimize impact to data center operations and business objectives Create an Energy Strategy which publicly states goals and milestones for the data center and for the enterprise 34

35 END For more information: 35

The Green/ Efficiency Metrics Conundrum. Anand Ekbote Vice President, Liebert Monitoring Emerson Network Power

The Green/ Efficiency Metrics Conundrum. Anand Ekbote Vice President, Liebert Monitoring Emerson Network Power The Green/ Efficiency Metrics Conundrum Anand Ekbote Vice President, Liebert Monitoring Emerson Network Power Agenda Green Grid, and Green/ Efficiency Metrics Data Center Efficiency Revisited Energy Logic

More information

Data Centre Energy Efficiency: A Call To Action

Data Centre Energy Efficiency: A Call To Action Data Centre Energy Efficiency: A Call To Action Vic Smith, The Green Grid, EMEA Technical Work Group Chair Dell, Senior Strategic Technologist Agenda Overview of The Green Grid Mission Community of Members

More information

Power, Cooling and Energy Consumption for Petascale and Beyond

Power, Cooling and Energy Consumption for Petascale and Beyond Headline in Arial Bold 30pt Power, Cooling and Energy Consumption for Petascale and Beyond SC07 Birds-of-a-Feather 14-Nov-07 Agenda ASHRAE TC9.9 Overview (Tim McCann, SGI) The Green Grid Overview (Tahir

More information

Harmonizing Global Metrics for Data Center Energy Efficiency

Harmonizing Global Metrics for Data Center Energy Efficiency Harmonizing Global Metrics for Data Center Energy Efficiency Dan Azevedo, Symantec Chairman - Metrics & Measurements Work Group Industry Trends Energy Efficient IT The Climate Group: Smarter technology

More information

Green Data Centers. Energy Efficiency Data Centers. André ROUYER Director of Standardization & Environment. The importance of standardization

Green Data Centers. Energy Efficiency Data Centers. André ROUYER Director of Standardization & Environment. The importance of standardization Green Data Centers GOING FORWARD ENERGY EFFICIENCY TRENDS André ROUYER Director of Standardization & Environment All content in this presentation is protected 2008 American Power Conversion Corporation

More information

Re Engineering to a "Green" Data Center, with Measurable ROI

Re Engineering to a Green Data Center, with Measurable ROI Re Engineering to a "Green" Data Center, with Measurable ROI Alan Mamane CEO and Founder Agenda Data Center Energy Trends Benchmarking Efficiency Systematic Approach to Improve Energy Efficiency Best Practices

More information

Managing Power Usage with Energy Efficiency Metrics: The Available Me...

Managing Power Usage with Energy Efficiency Metrics: The Available Me... 1 of 5 9/1/2011 1:19 PM AUG 2011 Managing Power Usage with Energy Efficiency Metrics: The Available Metrics and How to Use Them Rate this item (1 Vote) font size Data centers consume an enormous amount

More information

ENERGY STAR for Data Centers

ENERGY STAR for Data Centers ENERGY STAR for Data Centers Alexandra Sullivan US EPA, ENERGY STAR February 4, 2010 Agenda ENERGY STAR Buildings Overview Energy Performance Ratings Portfolio Manager Data Center Initiative Objective

More information

Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM)

Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM) Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM) Salim Janbeh Physical Infrastructure Consultant uae-sj@panduit.com PANDUIT You Can t Manage What You Don t Measure:

More information

DOE Data Center Energy Efficiency Program

DOE Data Center Energy Efficiency Program DOE Data Center Energy Efficiency Program Paul Scheihing U.S. Department of Energy Energy Efficiency and Renewable Energy April 2009 1 DOE Industrial Technologies Program Worki king to improve th e energy

More information

Zen Internet Case Study

Zen Internet Case Study Zen Internet Case Study About Zen Internet Zen Internet is an independent Internet Service Provider (ISP) that offers a full range of data, voice, and hosting services to businesses and residential users

More information

Greener Pastures for Your Data Center

Greener Pastures for Your Data Center W H I T E P A P E R Greener Pastures for Your Data Center 2 Executive Summary Following a green path, once a concept relegated to a small group of environmentalists and the U.S. Environmental Protection

More information

AT&T Global Network Client for Windows Product Support Matrix January 29, 2015

AT&T Global Network Client for Windows Product Support Matrix January 29, 2015 AT&T Global Network Client for Windows Product Support Matrix January 29, 2015 Product Support Matrix Following is the Product Support Matrix for the AT&T Global Network Client. See the AT&T Global Network

More information

EU Code of Conduct for Data Centre Efficiency

EU Code of Conduct for Data Centre Efficiency EU Code of Conduct for Data Centre Efficiency A Green Practice Accredited by British Computer Society (BCS) EU Code of Conduct for Data Centre Efficiency Local Organizer Practices in Data Centre Industry

More information

Published 2Q 2012. Eric Woods Research Director. Clint Wheelock President

Published 2Q 2012. Eric Woods Research Director. Clint Wheelock President EXECUTIVE SUMMARY: Green Data Centers IT Equipment, Power and Cooling Infrastructure, and Monitoring and Management Tools: Global Industry Drivers, Market Analysis, and Forecasts NOTE: This document is

More information

Auditing a data centre but to what standard?

Auditing a data centre but to what standard? Auditing a data centre but to what standard? Matt Flowerday RCDD Capitoline LLP mflowerday@capitoline.co.uk www.capitoline.me Data centre auditing Capitoline has audited over 30 data centres in the UK,

More information

Data Center Energy Use, Metrics and Rating Systems

Data Center Energy Use, Metrics and Rating Systems Data Center Energy Use, Metrics and Rating Systems Steve Greenberg Energy Management Engineer Environmental Energy Technologies Division Lawrence Berkeley National Laboratory October 31, 2007 Today s s

More information

Table of Contents. 2 Why IT Organizations Everywhere Need to go Green. 3 Greening the Data Center

Table of Contents. 2 Why IT Organizations Everywhere Need to go Green. 3 Greening the Data Center WHITE PAPER: Energy Efficiency Go Green: Energy Efficiency for the IT Organization Table of Contents 2 Why IT Organizations Everywhere Need to go Green 3 Greening the Data Center 5 Savvis Commitment to

More information

Cisco and VMware Virtualization Planning and Design Service

Cisco and VMware Virtualization Planning and Design Service Cisco and VMware Virtualization Planning and Design Service Create an End-to-End Virtualization Strategy with Combined Services from Cisco and VMware Service Overview A Collaborative Approach to Virtualization

More information

Sustainability Watch. Data Center Energy Efficiency. Data Center Energy Efficiency Is Fast Becoming a Priority. Watch List.

Sustainability Watch. Data Center Energy Efficiency. Data Center Energy Efficiency Is Fast Becoming a Priority. Watch List. 2009 Is Fast Becoming a Priority Watch List Generally accepted energy performance metrics and requirements for servers (as well as data centers) is an EPA priority and will likely be clearly defined in

More information

Data Centers: Definitions, Concepts and Concerns

Data Centers: Definitions, Concepts and Concerns Data Centers: Definitions, Concepts and Concerns Arash Mousavi DCC September 2013 Agenda 1. Introduction 2. Issues in Modern Data Centers: Siemens Integrated Data Center Solutions 3. Issues in Modern Data

More information

Analysis One Code Desc. Transaction Amount. Fiscal Period

Analysis One Code Desc. Transaction Amount. Fiscal Period Analysis One Code Desc Transaction Amount Fiscal Period 57.63 Oct-12 12.13 Oct-12-38.90 Oct-12-773.00 Oct-12-800.00 Oct-12-187.00 Oct-12-82.00 Oct-12-82.00 Oct-12-110.00 Oct-12-1115.25 Oct-12-71.00 Oct-12-41.00

More information

Green Data Centre: Is There Such A Thing? Dr. T. C. Tan Distinguished Member, CommScope Labs

Green Data Centre: Is There Such A Thing? Dr. T. C. Tan Distinguished Member, CommScope Labs Green Data Centre: Is There Such A Thing? Dr. T. C. Tan Distinguished Member, CommScope Labs Topics The Why? The How? Conclusion The Why? Drivers for Green IT According to Forrester Research, IT accounts

More information

Guideline for Water and Energy Considerations During Federal Data Center Consolidations

Guideline for Water and Energy Considerations During Federal Data Center Consolidations Guideline for Water and Energy Considerations During Federal Data Center Consolidations Prepared for the U.S. Department of Energy Federal Energy Management Program By Lawrence Berkeley National Laboratory

More information

Solutions to Make Your Data Center Energy Effi cient

Solutions to Make Your Data Center Energy Effi cient Common $en e: Solutions to Make Your Data Center Energy Effi cient Energy effi ciency is a life style. It s also common sense. In a data center, the name of the game is effi ciency and how many compute

More information

Global Green Data Center Best Practices In Action

Global Green Data Center Best Practices In Action Global Green Data Center Best Practices In Action DOUG WASHBURN VICE PRESIDENT & RESEARCH DIRECTOR September 25, 2013 Four questions I will answer 1 Why is green important to your business? 2 Why is green

More information

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure White Paper Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure White Paper March 2014 2014 Cisco and/or its affiliates. All rights reserved. This

More information

Green Data Centre Design

Green Data Centre Design Green Data Centre Design A Holistic Approach Stantec Consulting Ltd. Aleks Milojkovic, P.Eng., RCDD, LEED AP Tommy Chiu, EIT, RCDD, LEED AP STANDARDS ENERGY EQUIPMENT MATERIALS EXAMPLES CONCLUSION STANDARDS

More information

Data Center Energy Efficiency Looking Beyond PUE

Data Center Energy Efficiency Looking Beyond PUE Data Center Energy Efficiency Looking Beyond PUE No Limits Software White Paper #4 By David Cole 2011 No Limits Software. All rights reserved. No part of this publication may be used, reproduced, photocopied,

More information

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS* COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) 2 Fixed Rates Variable Rates FIXED RATES OF THE PAST 25 YEARS AVERAGE RESIDENTIAL MORTGAGE LENDING RATE - 5 YEAR* (Per cent) Year Jan Feb Mar Apr May Jun

More information

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS* COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) 2 Fixed Rates Variable Rates FIXED RATES OF THE PAST 25 YEARS AVERAGE RESIDENTIAL MORTGAGE LENDING RATE - 5 YEAR* (Per cent) Year Jan Feb Mar Apr May Jun

More information

Storage Systems Can Now Get ENERGY STAR Labels and Why You Should Care. PRESENTATION TITLE GOES HERE Dennis Martin President, Demartek

Storage Systems Can Now Get ENERGY STAR Labels and Why You Should Care. PRESENTATION TITLE GOES HERE Dennis Martin President, Demartek Storage Systems Can Now Get ENERGY STAR Labels and Why You Should Care PRESENTATION TITLE GOES HERE Dennis Martin President, Demartek Agenda About Demartek Energy Efficiency in the Home and in Data Centers

More information

Case 2:08-cv-02463-ABC-E Document 1-4 Filed 04/15/2008 Page 1 of 138. Exhibit 8

Case 2:08-cv-02463-ABC-E Document 1-4 Filed 04/15/2008 Page 1 of 138. Exhibit 8 Case 2:08-cv-02463-ABC-E Document 1-4 Filed 04/15/2008 Page 1 of 138 Exhibit 8 Case 2:08-cv-02463-ABC-E Document 1-4 Filed 04/15/2008 Page 2 of 138 Domain Name: CELLULARVERISON.COM Updated Date: 12-dec-2007

More information

DECREASING DATACENTER AND OTHER IT ENERGY

DECREASING DATACENTER AND OTHER IT ENERGY The Green Grid Opportunity DECREASING DATACENTER AND OTHER IT ENERGY USAGE PATTERNS february 16, 2007 white paper 1 Gartner analysts advise enterprises to make the most efficient use of existing systems

More information

EMC PERSPECTIVE Managing Energy Efficiency in the Data Center

EMC PERSPECTIVE Managing Energy Efficiency in the Data Center EMC PERSPECTIVE Managing Energy Efficiency in the Data Center A tactical approach can deliver immediate problem resolution plus long-term savings and efficiencies Managing Energy Efficiency in the Data

More information

Cisco Services for IPTV

Cisco Services for IPTV Cisco Services for IPTV Cisco Services for IPTV help service providers efficiently launch IPTV services while mitigating risk and providing service assurance. Opportunity The media services landscape is

More information

PANDUIT ONE PARTNER PROGRAM

PANDUIT ONE PARTNER PROGRAM PANDUIT ONE PARTNER PROGRAM SM Enabling Partners to Deliver the Most Efficient Solutions and Superior Value to Their Customers To Panduit, ONE means: ONE organization we are an extension of your organization,

More information

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint Energy usage in the data center Electricity Transformer/ UPS Air 10% Movement 12% Cooling 25% Lighting, etc. 3% IT Equipment

More information

Data Center Solutions - Modular Design

Data Center Solutions - Modular Design June 29, 2010 Issue Dustin Kehoe Current Analysis Principal Analyst, The economics of data centers are completely out of sync for many enterprises. This is caused by a range of interconnected variables

More information

Datacenter Efficiency

Datacenter Efficiency EXECUTIVE STRATEGY BRIEF Operating highly-efficient datacenters is imperative as more consumers and companies move to a cloud computing environment. With high energy costs and pressure to reduce carbon

More information

Climatography of the United States No. 20 1971-2000

Climatography of the United States No. 20 1971-2000 Climate Division: CA 6 NWS Call Sign: SAN Month (1) Min (2) Month(1) Extremes Lowest (2) Temperature ( F) Lowest Month(1) Degree s (1) Base Temp 65 Heating Cooling 100 Number of s (3) Jan 65.8 49.7 57.8

More information

Green Evaluation Metrics and Software Tool for Data Center

Green Evaluation Metrics and Software Tool for Data Center Green Evaluation Metrics and Software Tool for Data Center Wong Hui Shin Faculty of Computing and Informatics, Multimedia University, Cyberjaya, Selangor, Malaysia. hswong@mmu.edu.my Saravanan Muthaiyah

More information

Power Usage Effectiveness (PUE) & Data Center Infrastructure Efficiency (DCiE) Progress

Power Usage Effectiveness (PUE) & Data Center Infrastructure Efficiency (DCiE) Progress Power Usage Effectiveness (PUE) & Data Center Infrastructure Efficiency (DCiE) Progress Dan Azevedo, Symantec Jon Haas, Intel Jud Cooley, Sun Microsystems, Inc. Mark Monroe, Sun Microsystems, Inc. Pam

More information

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server High availability for lower expertise

More information

Increasing Energ y Efficiency In Data Centers

Increasing Energ y Efficiency In Data Centers The following article was published in ASHRAE Journal, December 2007. Copyright 2007 American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. It is presented for educational purposes

More information

DATA CENTERS: AN ACCOUNT OF FEDERAL INITIATIVES AND DATA CENTER ASSESSMENTS FOR FACILITY MANAGERS. David Cosaboon, LEED AP O+M

DATA CENTERS: AN ACCOUNT OF FEDERAL INITIATIVES AND DATA CENTER ASSESSMENTS FOR FACILITY MANAGERS. David Cosaboon, LEED AP O+M P a g e 1 DATA CENTERS: AN ACCOUNT OF FEDERAL INITIATIVES AND DATA CENTER ASSESSMENTS FOR FACILITY MANAGERS David Cosaboon, LEED AP O+M Facility Engineering Associates, P.C. 12701 Fair Lakes Circle, Suite

More information

DATA CENTERS BEST IN CLASS

DATA CENTERS BEST IN CLASS Data Energy Audit Chameleon Data Center DATA CENTERS BEST IN CLASS... By Wouter Kok, MSc, Strategic Advisor Global Data Center Practice Deerns leads the way in making data centers greener, by reducing

More information

Page 1. White Paper, December 2012 Gerry Conway. How IT-CMF can increase the Energy Efficiency of Data Centres

Page 1. White Paper, December 2012 Gerry Conway. How IT-CMF can increase the Energy Efficiency of Data Centres Page 1 White Paper, December 2012 Gerry Conway How IT-CMF can increase the Energy Efficiency of Data Centres Abstract Data centres and their management are under increasing pressure; to increase the efficiency

More information

Ashley Institute of Training Schedule of VET Tuition Fees 2015

Ashley Institute of Training Schedule of VET Tuition Fees 2015 Ashley Institute of Training Schedule of VET Fees Year of Study Group ID:DECE15G1 Total Course Fees $ 12,000 29-Aug- 17-Oct- 50 14-Sep- 0.167 blended various $2,000 CHC02 Best practice 24-Oct- 12-Dec-

More information

Knowledge Base and Research Report

Knowledge Base and Research Report Knowledge Base and Research Report Copyright 2010, GreenWay Collaborative. All Rights Reserved. 46 Kent Hills Lane Wilton, CT Phone: (203) 429-8951 Cell: (203) 246-1156 Contact: Cal Braunstein cbraunstein@rfgonline.com

More information

Report Information. Global Green Data Center Market 2015-2019. Market overview of green data centers

Report Information. Global Green Data Center Market 2015-2019. Market overview of green data centers Report Information Global Green Data Center Market 2015-2019 Report / Search Code: WGR155710 Publish Date: 9 September, 2015 Report Price: 1-user PDF : $ 2500.0 1-5 User PDF : $ 3000.0 Enterprise PDF :

More information

Energy Savings in the Data Center Starts with Power Monitoring

Energy Savings in the Data Center Starts with Power Monitoring Energy Savings in the Data Center Starts with Power Monitoring As global competition intensifies, companies are increasingly turning to technology to help turn mountains of data into a competitive edge.

More information

The Green Grid, Metrics and DCMM. Presented by: Jay Taylor

The Green Grid, Metrics and DCMM. Presented by: Jay Taylor The Green Grid, Metrics and DCMM Presented by: Jay Taylor About The Green Grid A not-for-profit international consortium committed to advancing resource efficiency in business computing ecosystems and

More information

The Efficient Enterprise. Juan Carlos Londoño Data Center Projects Engineer APC by Schneider Electric

The Efficient Enterprise. Juan Carlos Londoño Data Center Projects Engineer APC by Schneider Electric Ee The Efficient Enterprise Juan Carlos Londoño Data Center Projects Engineer APC by Schneider Electric Keystrokes Kilowatts Heat OUT Electricity IN Need for bandwidth exploding Going hyperbolic! 30,000

More information

Data Acquisition: The Gateway to Energy Monitoring and Efficiency of Existing Buildings

Data Acquisition: The Gateway to Energy Monitoring and Efficiency of Existing Buildings Data Acquisition: The Gateway to Energy Monitoring and Efficiency of Existing Buildings By Rick Schear, Product Manager, Connectivity and Communications, Eaton Corp. and John White, Director, Energy Management

More information

Identifying Energy Saving Opportunities in the Data Center

Identifying Energy Saving Opportunities in the Data Center Identifying Energy Saving Opportunities in the Data Center Andrew Fanara US EPA ENERGY STAR Product Development Fanara.andrew@epa.gov (206) 553-6377 (Seattle, WA) 1 Data Centers are INFORMATION FACTORIES

More information

Energy Efficiency and Availability Management in Consolidated Data Centers

Energy Efficiency and Availability Management in Consolidated Data Centers Energy Efficiency and Availability Management in Consolidated Data Centers Abstract The Federal Data Center Consolidation Initiative (FDCCI) was driven by the recognition that growth in the number of Federal

More information

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America 7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer

More information

Reducing Data Center Energy Consumption

Reducing Data Center Energy Consumption Reducing Data Center Energy Consumption By John Judge, Member ASHRAE; Jack Pouchet, Anand Ekbote, and Sachin Dixit Rising data center energy consumption and increasing energy costs have combined to elevate

More information

GREEN ICT DELL, OUR SUPPLIERS AND CUSTOMERS

GREEN ICT DELL, OUR SUPPLIERS AND CUSTOMERS GREEN ICT DELL, OUR SUPPLIERS AND CUSTOMERS Victor C. Smith Senior Strategic Technologist Dell Corporation Ltd. GROWTH EVERY SECOND IN THE CONNECTED AGE 2 new blogs created 4 cell phones purchased 7 personal

More information

WHITE PAPER. How To Build A Real Green Data Centre. Contents. Part 1: Drivers for Data Centre energy efficiency. February 2008

WHITE PAPER. How To Build A Real Green Data Centre. Contents. Part 1: Drivers for Data Centre energy efficiency. February 2008 NORMAN DISNEY & YOUNG LEVEL 1 60 MILLER STREET NORTH SYDNEY AUSTRALIA 2060+61 2 9928 6800 +61 2 9955 6900 URL www.ndy.comndy MANAGEMENT PTY LIMITED TRADING AS NORMAN DISNEY & YOUNG ABN 29 003 234 571 `

More information

Jeff Haby, P.E. Director Sewer System Improvements. September 15, 2015. Agenda

Jeff Haby, P.E. Director Sewer System Improvements. September 15, 2015. Agenda SAWS Sanitary Sewer Overflow Reduction Program Jeff Haby, P.E. Director Sewer System Improvements SA Military Engineers Meeting Agenda SAWS Overview Consent Decree CD Compliance Programs Program Transition

More information

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and IBM FlexSystem Enterprise Chassis

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and IBM FlexSystem Enterprise Chassis White Paper Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and IBM FlexSystem Enterprise Chassis White Paper March 2014 2014 Cisco and/or its affiliates. All rights reserved. This document

More information

How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems

How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems Paul Mathew, Ph.D., Staff Scientist Steve Greenberg, P.E., Energy Management Engineer

More information

VISIT 2010 Fujitsu Forum Europe 0

VISIT 2010 Fujitsu Forum Europe 0 VISIT 2010 Fujitsu Forum Europe 0 Virtualization & Automation Room 13a Shaping tomorrow with you. Green Data Center Services Martin Provoost Director, Data Centers and Networks, Fujitsu UK & Ireland 14:00

More information

How green is your data center?

How green is your data center? Siemens Answers: Sustainable Future How green is your data center? Istanbul June 01, 2010 Agenda 1 Solution 2 Siemens Data Center Approach 2 Designing with multiple power density zones can reduce energy

More information

Critical Environment Risk Management

Critical Environment Risk Management DATA CENTRE SECTOR Critical Environment Risk Management for Data Centres Exceptional Service, Exceptional People Data centre experience Norland supports some of the world s leading enterprise data centres

More information

FEEDBACK from Higher Learning Commission Review - October 2015

FEEDBACK from Higher Learning Commission Review - October 2015 FEEDBACK from Higher Learning Commission Review - October 2015 Title SARS - Early Alert and Scheduling System Category 1-Helping Students Learn Timeline 1: CURRENT PROJECT STATUS SUMMARY General Project

More information

The Thinking Approach LEAN CONCEPTS. 2012-2013, IL Holdings, LLC All rights reserved 1

The Thinking Approach LEAN CONCEPTS. 2012-2013, IL Holdings, LLC All rights reserved 1 The Thinking Approach LEAN CONCEPTS All rights reserved 1 Basic Thinking to Manage the Journey MANAGEMENT TACTICS OF A LEAN TRANSFORMATION All rights reserved 2 LEAN MANAGEMENT Two key questions What is

More information

Products and Services

Products and Services Products and Services Canvas Systems is the largest global independent reseller of refurbished server hardware, with over 13 years of experience within the industry. With over 50 million worth of new and

More information

Climatography of the United States No. 20 1971-2000

Climatography of the United States No. 20 1971-2000 Climate Division: CA 4 NWS Call Sign: Month (1) Min (2) Month(1) Extremes Lowest (2) Temperature ( F) Lowest Month(1) Degree s (1) Base Temp 65 Heating Cooling 1 Number of s (3) Jan 59.3 41.7 5.5 79 1962

More information

Overview of Green Energy Strategies and Techniques for Modern Data Centers

Overview of Green Energy Strategies and Techniques for Modern Data Centers Overview of Green Energy Strategies and Techniques for Modern Data Centers Introduction Data centers ensure the operation of critical business IT equipment including servers, networking and storage devices.

More information

Data Center Efficiency Metrics: mpue, Partial PUE, ERE, DCcE

Data Center Efficiency Metrics: mpue, Partial PUE, ERE, DCcE Data Center Efficiency Metrics: mpue, Partial PUE, ERE, DCcE Dan Azevedo, Symantec Jud Cooley, Oracle Michael Patterson, Intel Mark Blackburn, 1E Join The Green Grid Technical Forum conversation on Twitter!

More information

Dallas/Fort Worth International Airport District Energy Plant Upgrades Project Making More with Less Sustainable Communities Conference Dallas, TX

Dallas/Fort Worth International Airport District Energy Plant Upgrades Project Making More with Less Sustainable Communities Conference Dallas, TX Dallas/Fort Worth International Airport District Energy Plant Upgrades Project Making More with Less Sustainable Communities Conference Dallas, TX March 10, 2009 Agenda DFW Capital Development Program

More information

Figure 1: Comparison of Projected Electricity Use, 2007-2011 1

Figure 1: Comparison of Projected Electricity Use, 2007-2011 1 Fact Sheet on National Data Center Energy Efficiency Information Program U.S. Department of Energy (DOE) and U.S. Environmental Protection Agency (EPA) March 19, 2008 Summary: The voluntary National Data

More information

Unleashing Stranded Power and Cooling Data

Unleashing Stranded Power and Cooling Data Unleashing Stranded Power and Cooling from New and Existing Data Centers An affordable, five-step approach to addressing power and cooling shortages By Dr. Kenneth Uhlman, P.E. Director of Data Center

More information

Intelligent Data Center Solutions

Intelligent Data Center Solutions Intelligent Data Center Solutions Panduit s Unified Physical Infrastructure (UPI): a Guiding Vision A unified approach to physical and logical systems architecture is imperative for solutions to fully

More information

ALWAYS ON GLOBALSWITCH.COM

ALWAYS ON GLOBALSWITCH.COM ALWAYS ON GLOBALSWITCH.COM Data Centre Design Considerations Kelvin Fong Managing Director, Hong Kong ALWAYS ON GLOBALSWITCH.COM Agenda 1. Introduction to Global Switch 2. Customer Requirements 3. Development

More information

ABSTRACT DCMCCT PROJECT OVERVIEW

ABSTRACT DCMCCT PROJECT OVERVIEW Title: Case Study of the Austin Energy Dell Regional Children s Medical Center of Central Texas Packaged Hybrid CHP Energy Plant in Austin, Texas Authors: Mr. Ed Mardiat, Burns & McDonnell Mr. Jim Teigen,

More information

Data Center Energy Efficiency and Demonstration Projects

Data Center Energy Efficiency and Demonstration Projects Energy Research and Development Division FINAL PROJECT REPORT Data Center Energy Efficiency and Demonstration Projects Prepared for: Prepared by: California Energy Commission Lawrence Berkeley National

More information

Tools for Energy Tracking and Benchmarking. ENERGY STAR Portfolio Manager for Congregations

Tools for Energy Tracking and Benchmarking. ENERGY STAR Portfolio Manager for Congregations Tools for Energy Tracking and Benchmarking ENERGY STAR Portfolio Manager for Congregations Steve Bell (Contractor) Energy and Security Group LLC ENERGY STAR Congregations Why Does Green Start With Energy?

More information

Alexandria Overview. Sept 4, 2015

Alexandria Overview. Sept 4, 2015 Alexandria Overview Sept 4, 2015 Alexandria 1U System Block Diagram SAS Interface Board Zoneboard Zoneboard I2C UART SAS to SATA I2C 12V AC Power Supply Power 60w Supply Seagate Confidential Alexandria

More information

Auditing a Data Centre But to What Standard?

Auditing a Data Centre But to What Standard? Auditing a Data Centre But to What Standard? Barry Elliott, RCDD Capitoline LLP belliott@capitoline.co.uk www.capitoline.eu Data Centre Auditing Capitoline has audited over 30 data centres in the UK, Ireland,

More information

APPROACHABLE ANALYTICS MAKING SENSE OF DATA

APPROACHABLE ANALYTICS MAKING SENSE OF DATA APPROACHABLE ANALYTICS MAKING SENSE OF DATA AGENDA SAS DELIVERS PROVEN SOLUTIONS THAT DRIVE INNOVATION AND IMPROVE PERFORMANCE. About SAS SAS Business Analytics Framework Approachable Analytics SAS for

More information

Cisco Virtual Desktop Infrastructure Strategy Service

Cisco Virtual Desktop Infrastructure Strategy Service Cisco Virtual Desktop Infrastructure Strategy Service Build a Comprehensive Business Case for a Virtual Desktop Infrastructure Implementation The Cisco Virtual Desktop Infrastructure Strategy Service helps

More information

Nominee: FieldView Solutions, Inc.

Nominee: FieldView Solutions, Inc. Nominee: FieldView Solutions, Inc. Nomination title: FieldView Energy Nom FieldView Solutions: Data Center Energy Efficiency Product of the Year FieldView Solutions provides software to organizations to

More information

Transformational Managed Network Services

Transformational Managed Network Services Transformational Managed Network Services Accelerating your transformation to an IP world. Accenture Publishing Solutions 1 The Challenge Enterprises today are finding it increasingly difficult to reconcile

More information

The Open Cloud Near-Term Infrastructure Trends in Cloud Computing

The Open Cloud Near-Term Infrastructure Trends in Cloud Computing The Open Cloud Near-Term Infrastructure Trends in Cloud Computing Markus Leberecht BELNET Networking Conference 25-Oct-2012 1 Growth & IT Challenges Drive Need for Cloud Computing IT Pros Growth IT Challenges

More information

The Role of Building Maintenance in Energy Efficiency and Building Operations

The Role of Building Maintenance in Energy Efficiency and Building Operations The Role of Building Maintenance in Energy Efficiency and Building Operations The Role of Building Maintenance in Energy Efficiency and Building Operations The Role of Building Maintenance in Energy Efficiency

More information

DATA CENTER MATURITY MODEL

DATA CENTER MATURITY MODEL WHITE PAPER #36 DATA CENTER MATURITY MODEL EDITOR: Harkeeret Singh, Thomson Reuters CONTRIBUTORS: Dan Azevedo, Symantec David Ibarra, DPR Construction Rona Newmark, EMC Steve O Donnell, Enterprise Strategy

More information

Increasing Data Center Resilience While Lowering PUE

Increasing Data Center Resilience While Lowering PUE Increasing Data Center Resilience While Lowering PUE Nandini Mouli, Ph.D. President/Founder esai LLC mouli.nandini@gmail.com www.esai.technology Introduction esai LLC esai LLC: Is a Disadvantaged woman-owned

More information

Powering Today and Tomorrow. Energy Solutions

Powering Today and Tomorrow. Energy Solutions Powering Today and Tomorrow Energy Solutions Panduit s Unified Physical Infrastructure (UPI) A unified approach to physical and logical systems architecture is imperative for solutions to fully address

More information

Building the Energy-Smart Datacenter

Building the Energy-Smart Datacenter Building the Energy-Smart Datacenter How Dell PowerEdge servers, services, tools and partnerships can help customers save money by saving energy. As businesses grow, they need more computational capacity.

More information

PROJECTS SCHEDULING AND COST CONTROLS

PROJECTS SCHEDULING AND COST CONTROLS Professional Development Day September 27th, 2014 PROJECTS SCHEDULING AND COST CONTROLS Why do we need to Control Time and Cost? Plans are nothing; Planning is everything. Dwight D. Eisenhower Back to

More information

David Payne, P.E. Associate Director February 18, 2014

David Payne, P.E. Associate Director February 18, 2014 David Payne, P.E. Associate Director February 18, 2014 Overview of Texas A&M University State's first public institution of higher education, was opened on Oct. 4, 1876 as the Agricultural and Mechanical

More information

Smart Data Center Solutions

Smart Data Center Solutions Smart Data Center Solutions New Data Center Challenges Require New Solutions Data Center Architecture. Inside and Out. Data centers are mission-critical facilities. A silo-based approach to designing,

More information

Data Center Lifecycle and Energy Efficiency

Data Center Lifecycle and Energy Efficiency Data Center Lifecycle and Energy Efficiency Lifecycle infrastructure management, power management, thermal management, and simulation solutions enable data center modernization. White Paper October 2014

More information

Energy Efficiency and Green Data Centers. Overview of Recommendations ITU-T L.1300 and ITU-T L.1310

Energy Efficiency and Green Data Centers. Overview of Recommendations ITU-T L.1300 and ITU-T L.1310 Energy Efficiency and Green Data Centers Overview of Recommendations ITU-T L.1300 and ITU-T L.1310 Paolo Gemma Chairman of Working Party 3 of ITU-T Study Group 5 International Telecommunication Union Agenda

More information

Smart Metering Initiative ADWEA Program

Smart Metering Initiative ADWEA Program Smart Metering Initiative ADWEA Program Saeed Nassouri Technical Advisor Abu Dhabi Water & Electricity Authority (ADWEA) Dec 2010 Company Background SMART GRID Basics AMI Project Strategy Project Scope

More information

Protecting Our Information, Protecting Our Resources

Protecting Our Information, Protecting Our Resources Solutions For Business-Critical Continuity Protecting Our Information, Protecting Our Resources Energy Efficient Power And Cooling For IT And Telecommunications Network Infrastructures The Challenge You

More information