2 - TeSys motor starters: enclosed version

Size: px
Start display at page:

Download "2 - TeSys motor starters: enclosed version"

Transcription

1 Contents - TeSys motor starters: enclosed version Selection guide.... page / VARIO enclosed switch disconnectors b Pre-assembled.... page / b Assembled by the user... page / b Add-on modules... page / b VARIO enclosed switch disconnectors for the North American market, conforming to UL and CSA standards.... page /0 Enclosed thermal-magnetic motor circuit-breakers b TeSys GV ME v Standard.... page / v Assembly of a safety enclosure.... page / b TeSys GV PC...page / D.O.L. starters for motor control b 0. to 0 kw v With manual control and with magnetic circuit-breaker.... page / b. to kw v Without isolating device... page /0 v With isolating device.... page / b 0. to. kw v With -phase thermal overload relay.... page / b 0. to. kw v With thermal magnetic circuit-breaker and contactor... page /0 Star-delta starters for motor control b. to kw v Without isolating device... page / b. to kw v With isolating device.... page / b 0 to kw v Without isolating device... page / D.O.L. starters for control in category AC- b Without isolating device... page / b With isolating device.... page / 0 /0

2 integral contactor breaker and reversing contactor breaker b Enclosures and door interlock mechanisms for customer assembly... page / b For control and protection of motors... page / b For control and protection of resistive circuits in category AC-... page / b Auxiliary contact blocks and accessories... page / Enclosed D.O.L. starters for motor control for use in a machine subject to the application of Machinery Directive //CE b Non-reversing starters... page / b Reversing starters.... page / Enclosed D.O.L. starters for AS-Interface cabling system Selection guide.... page / b TeSys LF P and LF P.... page / b TeSys LF M and LF M.... page / 0 /

3 General selection guide Applications Type D.O.L. starters Standard starters Standard power ratings of -phase motors in AC- 00/ V kw 0.0 kw 0. 0 kw 0.. kw 0. kw Starters Isolation Manual p p p Auto p p Switch p Circuit-breaker p p p Fuse carrier Protection Short-circuit p p p Overload p p p p Communication References Non-reversing VpF VCFN VpFX GV ME GV PC GV LC GV NGC LE GVME LE M LE D Reversing LE K LE D Pages / and / /and / / /0 /0, / and / 0 /

4 Soft starters Starters for safety applications Starters for use on AS-Interface line Standard star-delta starters. kw 0.0 kw 0.0 kw 0.0 kw 0.0. kw. kw. kw p p p p p p p p p p p p p p p p p p p p p p p p p p p p LE K LE D GV ME LG K LG D LG K LG D LJ K LF P LF M LE K LE D LE F LE D LE D LE K LE D LE D LG K LJ K LF P LF M / and / / and / / /, /, / and / / and / /, / and / / and / 0 /

5 References VARIO enclosed switch disconnectors, pre-assembled VCF 0GE VCF GE Enclosed switch disconnectors for high performance applications b -pole rotary switch disconnectors, 0 to 0 A, conforming to IEC 0-- and IEC 00. b Marking on operator O b Padlockable operating handle (padlocks not included). b IP degree of protection enclosures, sealable and lockable. b Cover lockable in position I (ON) up to A rating. -pole main and Emergency Stop switch disconnectors () Operator lthe Power Incorporated Handle Front plate AC- Dimensions at 00 V switch body Red, standard, padlockable with up to padlocks (Ø to Ø shank) Red, long, padlockable with up to padlocks (Ø to Ø shanks) Possible attachments () Reference Weight mm A kw kg Yellow 0 x 0 Yellow 0 x 0 -pole main switch disconnectors () Black, standard, padlockable with up to padlocks (Ø to Ø shank) Black, long, padlockable with up to padlocks (Ø to Ø shank) Black 0 x 0 Black 0 x 0 0 V0 VCF 0GE V0 VCF 0GE V0 VCF 0GE 0.00 V VCF GE 0.00 V VCF GE V VCF GE V VCF GE V VCF GEN.0 0 V VCF GEN.0 0 V0 VBF 0GE V0 VBF 0GE V0 VBF 0GE 0.00 V VBF GE 0.00 V VBF GE V VBF GE V VBF GE V VBF GEN.0 0 V VBF GEN.0 Enclosed switch disconnectors for standard applications b -pole rotary switch disconnectors, 0 to A, conforming to IEC 0--. b Degree of protection IP. -pole main and Emergency Stop switch disconnectors () Operator lthe Power Incorporated Handle Front plate AC- Dimensions at 00 V switch body Red padlockable, either by (Ø shank) or by padlocks (Ø shank) Possible attachments () Reference Weight mm A kw kg Yellow 0 x 0 0 VN VCFN GE () 0.. VN 0 VCFN 0GE () V0 0 VCFN GE 0. V 0 VCFN GE 0. V 0 VCFN 0GE 0. () For VCF and VBF enclosures, see page / / 0 Dimensions: page / / Schemes: page /

6 References VARIO enclosed switch disconnectors, assembled by the user 0 Empty enclosures IP enclosure with red padlockable handle operator and yellow front plate (for mounting a main or Emergency Stop switch disconnector) For switch body lthe Possible attachments () Reference Weight VBFX GE VN, VN 0 V0 V A kg 0 VCFX GE 0.0 V0 V 0 VCFX GE 0.0 V 0 VCFX GE 0.0 IP enclosure with black padlockable handle and black front plate (for mounting a main switch disconnector) VN, VN 0 V0 V 0 VBFX GE 0.0 V0 V 0 VBFX GE 0.0 V 0 VBFX GE 0.0 Switch bodies for standard applications () Description Rating Reference Weight A kg -pole switch disconnectors 0 VN 0.0 VN Switch bodies for high performance applications () Description Rating Reference Weight A kg -pole switch disconnectors 0 V V V V 0.00 V 0.00 V0 0 V 0.00 V 0.00 () See pages / and / 0 Dimensions: page / Schemes: page / /

7 References VARIO enclosed switch disconnectors Add-on modules 0 VZ 0 VZ 0 Add-on modules for enclosures VCF and VBF Description Rating Reference Weight A kg Main pole module (mounted in enclosure) 0 VZ VZ VZ VZ 0.00 VZ VZ 0.00 VZ Neutral pole modules with early make and late break contacts 0 to VZ and VZ and 0 VZ 0.0 Earthing modules 0 to VZ and VZ and 0 VZ 0.0 VZ VZ 0 Description Type of contacts Reference Weight kg Auxiliary contact block modules with auxiliary contacts N/O + N/C () VZ 0.00 N/O + N/O VZ switch body add-on module on each side of the switch body VZ or VZ 0 + V0p or + VZ or VZ 0 or VZ or VZ + V0 + VZ or VZ or or VZ or VZ + to + VZ or VZ or or VZ 0p/VZ 0 to VZ + V + VZ 0p/VZ 0 to VZ add-on modules on each side of the switch body VZ 0p + VZ 0p + V0p + VZ 0p + VZ or VZ 0 or VZ or VZ VZ 0 + VZ 0 + V0 + VZ 0 + VZ or VZ 0 or VZ or VZ VZ + VZ + V + VZ + VZ or VZ 0 or VZ or VZ VZ + VZ + V + VZ + VZ or VZ 0 or VZ or VZ VZ + VZ + V + VZ + VZ or VZ 0 or VZ or VZ VZ + VZ + V + VZ + VZ or VZ 0 or VZ or VZ Note: 0 Schemes : page / /

8 References (continued) VARIO enclosed switch disconnectors Add-on modules 0 0 Add-on modules for enclosures VCFN GE and 0GE Description Rating Reference Weight A kg Main pole modules 0 VZN 0.00 VZN Neutral pole module 0 and VZN 0.00 with early make and late break contacts Earthing module 0 and VZN 0.0 Description Type of contacts Reference Weight kg Auxiliary contact block modules N/O late make contact VZN N/C early break contact VZN switch body 0 VZN or VZN VZN or VZN 0 or VN VZN or or VN 0 or VZN 0 or VZN 0 or VZN 0 or VZN 0 VZN 0 Schemes : page / /

9 Dimensions VARIO enclosed switch disconnectors Dimensions VCFN GE to VCFN 0GE 0 0, VCF or VBF 0GE to GE VCFX or VBFX GE to GE H b c c a a b c c H VpF 0GE to VpF GE, VpFX GE () 0 0 VpF GE and VpF GE () VpFX GE and VpFX GE () VCF or VBF GEN and GEN xø,, 0,, 0 References: pages / and / Schemes: page / /

10 Schemes VARIO enclosed switch disconnectors Schemes Switch disconnectors Enclosed or switch bodies Main pole module Neutral pole module /T /L /T /L /T /L Auxiliary contact blocks VZ VZ 0 VZN 0 VZN 0 0 References: pages / and / /

11 References VARIO enclosed switch disconnectors for the North American market, conforming to UL and CSA standards Enclosed switch disconnectors for high performance applications b -pole rotary switch disconnectors, to 0 A, conforming to IEC 0--, IEC 00, UL 0 and CSA. n. b Marking on operator O b Padlockable operating handle (padlocks not included). b NEMA type and type enclosures, IP degree of protection, sealable and lockable. -pole main and Emergency stop switch disconnectors () Operator Rating Standard Handle Front plate IEC UL power Dimensions (Ith) ratings of UL motors Red, standard, padlockable with up to padlocks (ØtoØ) Red, long, padlockable with up to padlocks (ØtoØ) Incorporated switch body Possible attachments Reference Weight 00 V 0 V 0 V 00 V mm A A HP HP HP kg Yellow 0 x 0 Yellow 0 x V VC GUN V VC GUN V VC GUN V VC GUN V VC GUN V VC GUN.0 Add-on modules for VC enclosure Description Rating Reference Weight Main pole module (mounted in enclosure) A VZ 0.00 VZ VZ 0.00 VZ 0.00 kg Neutral pole module with early make and late break contacts 0 to VZ and VZ and 0 VZ Earthing modules 0 to VZ and VZ and 0 VZ 0.0 VZ VZ Description Type of contacts Reference Weight kg Auxiliary contact block N/O + N/C () VZ 0.00 modules with auxiliary contacts N/O + N/O VZ add-on module on each side of the switch body 0 VZ or VZ VZ or VZ 0 or V or VZ or VZ + + VZ or VZ VZ 0 or to or VZ or VZ + + VZ or VZ or V or 0 VZ to VZ + + VZ to VZ /0

12 Dimensions, schemes VARIO enclosed switch disconnectors for the North American market, conforming to UL and CSA standards Dimensions VC GUN and VC GUN Fixing (rear view) xø,, VC GUN and VC GUN Fixing (rear view) 0, xø, VC GUN and VC GUN Fixing (rear view), 0, Schemes Switch disconnectors, xø, Enclosed switch disconnectors or switch bodies Main pole module Neutral pole module /L /L /T /T /L /T Auxiliary contact block modules VZ VZ 0 0 /

13 References Enclosed thermal-magnetic motor circuit-breakers GV ME and accessories, for customer assembly References Thermal-magnetic motor circuit-breakers GV ME For motor circuit-breakers and accessories: see pages /, / and /. Starters consisting of a GV ME motor circuit-breaker in an enclosure conform to standard IEC _ 000_ GV MC GV MP GV Ithe in enclosure (A) ME 0 ME 0 ME 0 ME 0 ME 0 ME 0 ME 0 ME 0 ME 0 ME ME ME 0 ME Enclosures for thermal-magnetic circuit-breakers GV ME Type Degree of protection Possible no. of side mounting auxiliary contact blocks on GV ME Reference Weight LH side RH side kg Surface mounting, double insulated with protective conductor. Sealable cover Flush mounting, with protective conductor ME IP GV MC0 0.0 IP GV MC or GV MCK0 () 0.0 IP for GV MC temperature < + C IP (front face) GV MP0 0. IP (reduced GV MP0 0. IP (front face) GV MP0 0.0 IP (reduced GV MP _ Front plate Description Reference Weight kg For direct control, through a panel, of a chassis mounted GV ME IP GV CP _ GV CP GV K0 Accessories common to all enclosures (to be ordered separately) Description Sold in lots of Unit reference Padlocking device () for GV ME operator (padlocking is only possible in the O position) Mushroom head Emergency stop pushbutton Ø 0 mm, red Sealing kit Neutral terminal to padlocks Ø to mm Weight kg GV V0 0.0 Spring return () GV K0 0.0 Latching () IP For enclosures and front plate Key release, key n GV K0 0.0 Turn to release GV K0 0. IP for temperature between + Cand+0 C + GV K0 () GV E0 0.0 IP for temperature between - 0 C and + 0 C 0 GV E AB VVUBL 0.0 Partition 0 AB ACBL 0.00 () Enclosure GV MCK0 GV K0 mushroom head Emergency stop pushbutton GV Mp0 /

14 References dimensions Enclosed thermal-magnetic motor circuit-breakers GV P (for customer assembly) References (continued) Thermal-magnetic motor circuit-breakers GV P For motor circuit-breakers and accessories: see pages / and /. GV P0: operational current in enclosure limited to 0 A. Starters consisting of a GV P motor circuit-breaker in an enclosure conform to standards IEC/EN 0-- and IEC/EN 0-. (), for thermal-magnetic circuit-breakers GV P, up to 0 A Composition () Type Degree of Reference Weight protection of enclosure kg b Metal enclosure, b Black handle LU AP Padlocking in ON/OFF position b Circuit-breaker/handle adapter Surface mounting IP IK 0 GV PC0.000 b Metal enclosure, b Red handle LU AP Padlocking in OFF position b Circuit-breaker/handle adapter Surface mounting IP IK 0 GV PC0.000 () For special applications a GV L Dimensions Ø,,, 0 0,,, 0 /

15 References Enclosed thermal-magnetic motor circuit-breakers GV ME and accessories Assembly of a safety enclosure Thermal-magnetic motor circuit-breakers GV ME For motor circuit-breakers and accessories: see pages /, / and /. Starters consisting of a GV ME motor circuit-breaker in an enclosure conform to standard IEC _ GV MC GV ME 0 Ithe in enclosure (A) ME 0 ME 0 ME 0 ME 0 ME 0 ME 0 ME 0 ME 0 ME ME ME 0 ME Enclosures for thermal-magnetic circuit-breakers GV ME Type Surface mounting, double insulated with protective conductor. Sealable cover Degree of protection Possible number of Reference side-mounting auxiliary contact blocks on GV ME ME Weight LH side RH side kg IP GV MC0 0.0 IP GV MC IP for temperature < + C or GV MCK0 () 0.0 GV MC Accessories common to all enclosures (to be ordered separately) Description Padlocking devices () for GV ME operator (padlocking is only possible in the O position) to padlocks Ø to mm Sold in lots of Unit reference Weight kg GV V _ Mushroom head Emergency stop pushbutton Ø 0 mm, red Spring return () GV K0 0.0 Latching () IP Key release, key n Turn to release GV K0 0.0 GV K0 0. GV K0 () 0.0 GV K0 Sealing kit Neutral terminal For enclosures and front plate IP for temperature between + C and + 0 C 0 GV E0 0.0 IP for temperature between - 0 C and + 0 C 0 GV E AB VVUBL 0.0 Partition 0 AB ACBL 0.00 () Enclosure GV MCK0 GV K0 mushroom head Emergency stop pushbutton GV Mp0 0 /

16 References (continued) Enclosed thermal-magnetic motor circuit-breakers GV ME and accessories Assembly of a safety enclosure Assembly of a safety enclosure (conforming to standards IEC 0--, IEC 00 and IEC 0) Type of product Page Reference Enclosure Opposite GV MCpp Circuit-breaker / GV MEpp Undervoltage trip or INRS trip () / GV Apppp Latching mushroom head Stop pushbutton Opposite or GV AXppp GV K0 or GV K0 or GV K0 0 /

17 Dimensions, mounting Enclosed thermal-magnetic motor circuit-breakers GV ME Dimensions Surface mounting enclosure GV MC0p () 0 Surface mounting enclosure GV MCK0 () 0, Mounting Flush mounting enclosures GV MP0p (panel cut-out) GV MP0p GV MP0, MP0 GV MP0, MP0 Front plate GV CP 0,... a,, 0,,..., GV a MP0, MP0 MP0, MP0 0 /

18 Schemes Enclosed thermal-magnetic motor circuit-breakers GV ME Schemes GV MEpp /L /L /L /T /T /T Instantaneous auxiliary contacts GV AE GV AE GV AE0 or Instantaneous auxiliary contacts and fault signalling contacts GV AD00 GV AD00 GV AD00 GV AD00 Instantaneous auxiliary contacts Short-circuit signalling contacts GV AN GV AN0 GV AM () () () () 0 0 () () () () 0 Voltage trips GV AUppp GV ASppp GV AXppp D D C C D D Wiring diagram for undervoltage trip used on potentially dangerous machines, conforming to INRS E E 0 AgG max /L /L /L D D E 0 /T /T /T E /

19 Characteristics, references D.O.L. starters with manual control, with magnetic circuit-breaker, 0. to 0 kw Characteristics () Conforming to standards IEC 0-, IEC 0-, VDE 00-0 and EN 0 Degree of protection conforming to IEC 0 GV LC: IP GV NGC: IP 0 Operational voltage Ue GV LC: 0 V GV NGC: 00 V Material Polycarbonate () References Control by black rotary handle, padlockable in Off position (up to padlocks with Ø shank, to be ordered separately) 0 Rating In Breaking capacity Icu conforming to IEC 0-0/ 0 V 00/ V 0 V 00 V Magnetic tripping current Id ± 0 % Reference Weight A ka ka ka ka A kg In GV LC00 () In GV LC00 () 0.0 GV LC0pp In GV LC00 () In GV LC00 () In GV LC0 () 0.0 GV LC0pp In GV LC0 () In GV LC00 () In GV NGC In GV NGC In GV NGC00.0 pp In GV NGC In GV NGC0.0 Variants Starters with control by red rotary handle on yellow background Add the letter R to the references selected above. Example: GV LC00 becomes GV LC00R. GV LC0 Enclosure without circuit-breaker, with rotary handle mounted on cover Description Rating Reference Weight A kg Black rotary handle. GV LC GV NGC0 0.0 Red rotary handle on yellow background. GV LC0R 0.00 GV NGC0R () Circuit-breaker characteristics: GV L: see pages / and / NG L () Avoid placing this material in contact with harsh substances (detergents, chlorine solvents, ketones, alcohol, aromatic GVAD or GVAM auxiliary contact block on the LH side and a GVAp trip on the /

20 Dimensions, scheme D.O.L. starters with manual control, with magnetic circuit-breaker, 0. to 0 kw Dimensions GV LC00 LC00 GV NGC0 NGC0 0 0, 0 Knock-outs or blanking plugs for cable glands Enclosure type At top At bottom ISO ISO GV LC x 0 or x x 0 or x GV NGC x 0 or x or x or x 0 x 0 or x or x or x 0 Scheme /L /L /L /T /T /T 0 /

21 Characteristics, references D.O.L. starters for motor control (). to kw, without isolating device Characteristics Conforming to standards IEC 0-- and IEC 0-, VDE 00-0, EN 0 Degree of protection conforming to IEC 0 IP : LE K IP : LEp D0 D IP : LEp D0 D Ambient air temperature Operation: C Operating positions Material Same as that of the contactors Polycarbonate (): LE K and LEp D0 D Sheet steel: LEp D0 D References LE Dpp LE Dpp Non-reversing starters Standard power ratings of -phase motors 0-0 Hz in category AC- 0 V 0 V V 0 V 00 V 0 V 0 V 00 V 0 V Maximum current I the up to Basic reference, to be completed by adding the voltage code () Weight kw kw kw kw kw kw A kg... LE D0pp LE Dpp LE Dpp.0. LE Dpp.0... LE Dpp LE D0pp LE D0pp.0. 0 LE Dpp.0 0 LE D0pp.0 LE Dpp.0 Reversing starters... LE K0pp.00. LE K0pp.00 LE D0pp ().00.. LE D0pp LE Dpp LE Dpp.0. LE Dpp.0... LE Dpp LE D0pp LE D0pp.0. 0 LE Dpp.0 0 LE D0pp.00 LE Dpp.000 () Overload protection must be provided by a thermal overload relay, to be ordered separately, see pages /0 () Avoid placing this material in contact with harsh substances (detergents, chlorine solvents, Volts a 0/0 Hz LE K B D E F M P U Q V N R LE, LE D B D E F FE M P U Q V N R () Selection according to the number of operating cycles, please consult your Regional Sales 0 Dimensions : page / Schemes : page / /0

22 References (continued) D.O.L. starters for motor control (). to kw, without isolating device Description Standard versions comprise: b For non-reversing starters: v green Start button I, v red Stop/Reset button O. LE DppA0 LE DppA0 b v v For reversing starters: LE K: - Start button A, - Start button E, - red Stop/Reset button. LE D0 D: - -position spring return selector switch I - II, - red Stop/Reset button O, LE D0 D: v - blue Reset button R. Variants (pre-assembled) Description Application the starter reference () No pushbuttons on cover green Start button I green Start button II red Stop/Reset button O LE D0 D LE D0 D LE D0 D A0 A LE DppA0 blue Reset button R LE D0 D LE K0 and K0 LE D0 D -position stay put selector switch ( I - O - II ) ( I : Automatic Start; O : Stop; II : Manual Start) blue Reset button R LE D0 D A0 A0 -position stay put selector switch O - I ( O : Stop; I : Manual Start) blue Reset button R LE D0 D A LE DppA LE DppA -position selector switch O - I spring return to centre position ( I : Manual start; O : Stop, stay put) blue Reset button R neutral terminal Fitted as standard on LE and LE D0 to D, LE and LE D0 to D starters ordered with V (M), 0 V (P) or 0 V (U) control supply Mounting of an LC D0 or D contactor in an enclosure identical to LE D () LE D0 D LE D0 D LE K0 and K0 LE D0 D LE D0 LE D Accessory (for customer assembly) Description Application Reference Weight kg Start pushbutton latching device for stay put operation (Start-Stop) () Example: LE D0FA0 () See dimensions page / A A T LE D0 D LA D Other versions Possible combinations of variants. 0 Schemes : page / /

23 Dimensions D.O.L. starters for motor control. to kw, without isolating device Dimensions LE D0 and D LE D0 and DppT LE D D and LE D0 D LE D0 D c 0 c c LE D LE D c Standard version. Standard version. 0 Standard version Variant A0 Variant A0 Variant A0 0 Variant A0. Variant A0.. Variant A0 Variant A0 Variant A0 0 Variant A Variant A 0 Variant A Variant A 0 c 0 0 c 0 LE K0 and K0 0 0 LE D0, LE D and LE D0 D LE D0 and D 0 c 0 c LE D LE D c Standard version Standard version Variant A0 Variant A0 0 Variant A0 Variant A0 Variant A Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom PG ISO PG ISO LE D0 and D x 0 x or x x 0 LE D D and LE D0 D x 0 or x x or x x 0 or x LE D0 x and x x 0 and x x and x x 0 and x LE D0 D, LE D0 and D x and x x 0 and x x and x x 0 and x LE or LE D0 and D x and x x 0 and x 0 x and x x 0 and x 0 LE K x and x x 0 x and x x 0 c References : pages /0 and / Schemes : page / /

24 Schemes D.O.L. starters for motor control. to kw, without isolating device Schemes LE D0 D LE D0 D Variant A0 or A0 KM L U L V W L A B LE K0, K0 LE K0, K0 Variant A0 L L L A I O KM KM A A A B A O Remote control l KM KM A A R O KM KM Remote control KM KM U V W B KM KM KM A A A A KM B KM KM KM A A A A KM LE D0 D LE D0 D LE D0 D, LE D0 D with variants A0 or A0 L L L A A R KM KM S I II O Remote control ll KM KM KM KM KM KM KM KM KM A A KM KM A A KM U V W B A A B A A Connections A B 0 V, 0 V, 0 V LE K, LE and LE D0 and D L Neutral LE and LE D D L Neutral terminal 0 V, 00 V, V, 0 V All products L L Other voltages LE and LE D0 D Terminal Terminal LE K, LE and LE D0 and D Direct connection 0 References : pages /0 and / Dimensions : page / /

25 Characteristics, references D.O.L. starters for motor control (). to kw, with isolating device Characteristics Conforming to standards IEC 0-- and IEC 0-, VDE 00-0, EN 0 Degree of protection conforming to IEC 0 IP : LEp K IP : LEp D0 D IP : LEp D0 D0 Ambient air temperature Operation: C Operating positions Material Same as that of the contactors Polycarbonate (): LEp K and LEp D0 D Sheet steel: LEp D0 D0 References LE Dpp Non-reversing starters Standard power ratings of -phase motors 0-0 Hz in category AC- 0 V 0 V 0 V 00 V V 0 V 00 V 0 V 0 V Maximum current I the up to by the customer Size Type am Basic reference, to be completed by adding the voltage code () Weight kw kw kw kw kw kw A A kg... 0 x 0 LE K0pp.0. 0 x LE K0pp.0 or LE D0pp () x LE D0pp x LE Dpp x 0 LE Dpp x LE Dpp x LE Dpp x 0 LE D0pp x LE D0pp.0. 0 x 0 LE Dpp.0 0 x 0 LE D0pp ().00 0 LE Dpp Reversing starters... 0 x 0 LE K0pp x LE K0pp.00 or LE D0pp ().0. 0 x LE D0pp x LE Dpp x 0 LE Dpp x LE Dpp.0... x LE Dpp x 0 LE D0pp x LE D0pp x 0 LE Dpp.0 0 x 0 LE D0pp.000 () Overload protection must be provided by a thermal overload relay, to be ordered separately, see pages /0 () Avoid placing this material in contact with harsh substances (detergents, chlorine solvents, ketones, alcohol, aromatic Volts a 0/0 Hz LEp K B D E F M P U Q V N R LEp D B D E F FE M P U Q V N R 0 Dimensions: page / Schemes: page / /

26 References (continued) D.O.L. starters for motor control (). to kw, with isolating device LE DppA0 Description Standard versions comprise: b For non-reversing starters: v LE K and LE D0 D - green Start button I, - red Stop/Reset button O. v LE D0 - no pushbuttons on cover b v v For reversing starters: LE K : - Start button A, - Start button E, - red Stop/Reset button. LE D0 D : - -position spring return selector switch I - II, - red Stop/Reset button O, LE D0 to D0: v - no pushbuttons on cover. Protection Power circuit Control circuit LE and LE K -pole isolating device None LE and LE D0 D -pole isolating device + additional pole LE and LE D D0 -pole isolating device + circuit-breaker GB CB0 Variants (pre-assembled) Description Application the starter reference () No pushbuttons on cover LE D0 D LE D0 D A0 LE DppA0 green Start button I green Start button II red Stop/Reset button O LE D0 D0 A blue Reset button R LE D0 D0 LE K0 and K0 LE D0 D LE D0 D0 neutral terminal Fitted as standard on LE D D0, LE D D and LE D0 D0 starters ordered with 0 V (M), 0 V (P) or 0 V (U) control supply LE K0 and K0 LE D0 D0 LE K0 and K0 LE D0 D LE D0 D0 A0 A Accessory (for customer assembly) Description Application Reference Weight kg Start pushbutton latching device for stay put operation (Start-Stop) () See previous page () Example: LE D0FA0 LE D0 D LA D Other versions Possible combinations of variants. 0 Dimensions: page / Schemes: page / /

27 Dimensions D.O.L. starters for motor control. to kw, with isolating device Dimensions LE K0 and K0, LE K0 and K0 0 0 c 0 () LE D0 D, LE D0 D c 0 c c LE K LE K LE D LE D Standard version Standard version. Variant A0 Variant A0 () For LE only Variant A0.. LE D0 D LE D0 D0, LE D0 a- 00 (), 0 c xmx c c a LE D LE D Standard version 0 LE D0, D0, D 00 Standard version Variant A0 0 LE D0 00 Variant A0 Variant A0 0 LE D0 00 Variant A Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom PG ISO PG ISO LE and LE D0 D x 0 or x or x or x 0 0 c x 0 or x or x or x 0 LE D0 D x 0 or x x 0 or x LE D0 and LE D0 x and x x 0 and x x and x x 0 and x LE D0 D, LE D0 and D x and x x 0 and x x and x x 0 and x LE D0 and LE D0 x and x x 0 and x 0 x and x x 0 and x 0 LE K and LE K x and x x 0 x and x x 0 a-0 a a+, 0 References : pages / and / Schemes : page / /

28 Schemes D.O.L. starters for motor control. to kw, with isolating device Schemes LE K0, K0 LE D0 D0 Q L L L A LE K0, K0 LE D0 D LE D0 D LE D0, LE D0 D with variant A0 or A0 A Q Q A F Q A F Q KM U V W B I O KM A A KM B I O KM KM A A B l O KM KM A A B O Remote control l KM A A KM LE K0, K0 LE K0, K0 Variant A0 L L L A A Q Q R O Remote control KM KM KM KM KM KM U V W B KM KM LE D0 LE D0 LE D0 D LE D0 D0 A A KM KM A A KM B A A A A KM Q L L L A Q Q O A F Q KM KM S I II O Remote control ll KM KM KM KM KM KM KM KM KM A A KM KM A A KM U V W B Connections A B 0 V, 0 V, 0 V LE and LE K, LE and LE D0 and D L Neutral LE D D0, LE D D and LE D0 D0 L Neutral terminal 0 V, 00 V, V, 0 V All products L L Other voltages LE and LE D0 D Terminal Terminal LE and LE D0 D0 Direct connection A A B A A 0 References : pages / and / Dimensions : page / /

29 Characteristics, references D.O.L. starters for motor control 0. to. kw with -phase thermal overload relay with protected phases Characteristics () Conforming to standards IEC 0--, IEC 0-, VDE 00-0 and EN 0 Degree of protection conforming to IEC 0 IP Ambient air temperature Operation: - to + 0 C Operating positions Same as for the TeSys K contactors Material Self-extinguishing ABS References Non-reversing starters Starter LE M, combined with short-circuit protection components, provides type or type coordination, depending on the type of devices used. Standard power ratings of -phase motors 0-0 Hz in category AC- 0 V 0 V 0 V 0 V 00 V V Setting range of thermal overload relay LR K () Basic reference, to be completed by adding the voltage code () Weight kw kw kw kw A kg LE Mpp LE Mpp LE Mpp LE Mpp LE Mpp LE Mpp LE Mpp LE Mpp 0.00 LE Mpppp.. 0 LE Mpp LE Mpp 0.00 Description Variant Replacement part b The standard version comprises: v TeSys contactor LC Kpp, v TeSys thermal overload relay LR K, v green Start button I, v red Stop/Reset button O/R, v yellow operating indicator. b Control may be pulsed or maintained. b An earth terminal and a neutral terminal are provided on the bottom of the enclosure. b For safey applications, see enclosed starters: GV MC, LG K, LG D, LG K, LG D, LJ K, LG K and LJ K. Starter without thermal overload relay LR K Delete the last digits of the starter references selected above. Example: LE Mpp Description Basic reference, to be completed by adding the voltage code () Weight kg Contactor LC KppA () For characteristics of TeSys K contactor, see pages /0 to / For characteristics of TeSys thermal overload relay LR K, see pages /0 and / The codes indicated below therefore correspond to the power circuit voltage Volts a 0/0 Hz Code B M P U Q V N R Example: 0/00 V -phase supply, kw motor: LE MQ Dimensions : page / Schemes : page / /

30 Dimensions, schemes D.O.L. starters for motor control 0. to. kw with -phase thermal overload relay with protected phases Dimensions LE M () ("/) Knock-outs or blanking plugs for cable glands Enclosure type At top At bottom PG ISO PG ISO LE M x to x x 0 or x x to x x 0 or x I Schemes LE M O/R L L L T T T A A Reset/OR /L U /L V M /L KM I W Choice of type of control built into the product Control by latching pushbuttons Control by spring return pushbuttons A B O A KM H A KM Connection A B 0 V, 0 V, 0 V L Neutral 0 V, 00 V, V, 0 V L L Other voltages Terminal Terminal A B I O/R A KM H A KM 0 References : page / /

31 Characteristics, references D.O.L. starters for motor control, 0. to. kw with thermal magnetic circuit-breaker and contactor 0 Characteristics Conforming to standards IEC 0--, IEC 0-, VDE 00-0 and EN 0 Degree of protection conforming to IEC 0 IP Ambient air temperature Operation: - to + 0 C Operating positions Same as for the TeSys K contactors Material Polycarbonate () References Standard power ratings of -phase motors 0-0 Hz in category AC- 0 V 00/ 0 V 00 V 0 V V Setting range of thermal trips Fixed magnetic tripping current Irth Basic reference, to be completed by adding the voltage code () Weight kw kw kw kw kw A A kg LE GVME0Kpp LE GVME0Kpp LE GVME0Kpp.0 LE GVMEppKpp Variants LE GVME0Kpp LE GVMEKpp.0 0 LE GVMEKpp.0 Description Weight to the starter reference () kg Neutral terminal A LE GVMEK Description Reference Weight kg (references of combination motor starters for customer assembly, see pages / and /) LE GVMEK Accessories (to be ordered separately) Description Padlocking device () to padlocks for GV ME operator (padlocking Ø to mm is only possible in the O position) Mushroom head Stop pushbutton Ø 0 mm, red Sealing kit Sold in lots of Unit reference Weight kg GV V0 0.0 Spring return () GV K0 0.0 Latching () IP Key release, GV K0 0.0 key n Turn to release GV K0 0. GV K0 () 0.0 IP for 0 GV E0 0.0 temperature between + C and + 0 C IP for 0 GV E0 0.0 temperature between - 0 C and + 0 C () Avoid placing this material in contact with harsh substances (detergents, chlorine solvents, Volts a 0/0 Hz Item B D E F M P U Q V N R () Example: LE GVME0KFA Dimensions : page / Schemes : page / /0

32 Dimensions, schemes D.O.L. starters for motor control, 0. to. kw with thermal magnetic circuit-breaker and contactor Dimensions LE GVMEK 0 Knock-outs or blanking plugs for cable glands Enclosure type At top At bottom ISO ISO LE GV x 0 or x x 0 or x Schemes LE GVMEK 0 A L L L Q Q O External control I KM KM KM A B A Connections A B 0 V, 0 V, 0 V L Neutral 0 V, 00 V, V, 0 V L L Other voltages Terminal Terminal 0 References : page /0 /

33 Characteristics, references Star-delta starters. to kw, without isolating device () Characteristics Conforming to standards IEC 0-- and IEC 0-, VDE 00-0, EN 0 Degree of protection conforming to IEC 0 IP : LE K IP : LE D0 D IP : LE D0 D0 Ambient air temperature Operation: - to + 0 C Operating positions Material References Same as that of the contactors Polycarbonate (): LE K and LE D0 D Sheet steel: LE D0 D0 Maximum operating rate: LE K: starts/hour and LE-D: 0 starts/hour. Maximum starting time: 0 seconds. LE D: an LAD S timer imposes a delay of 0 ms ± ms on the delta contactor at time. Standard power ratings of squirrel cage motors Mains voltage - delta connection Basic reference, to be completed by adding the voltage code () Weight 0 V 0/00 V V 0 V kw kw kw kw kg... LE K0pp.0... LE K0pp.0 or LE D0pp ().0 LE Dpp. LE Dpp.0. LE Dpp LE Dpp.0. LE D0pp.0 0 LE D0pp.0 LE D0pp LE Dpp.00 LE D0pp.00 pages /0 () Avoid placing this material in contact with harsh substances (detergents, chlorine solvents, Volts a 0/0 Hz LE K B D E F M P U LE D B D E F FE M P U Q V N R () Selection according to dimensions and the number of operating cycles, please consult your 0 Dimensions : page / Schemes : page / /

34 References (continued) Star-delta starters. to kw, without isolating device Description The standard version comprises: b LE K and LE D0 D: v green Start button I, v red Stop/Reset button O. LE DppA0 b LE D0 D0: v no pushbuttons on cover. Variants (pre-assembled) Description Application the starter reference () No pushbuttons on cover LE D0 D A0 green Start button I red Stop/Reset button O LE D0 D0 A0 blue Reset button R LE D0 D0 A0 neutral terminal Fitted as standard on starters LE D and D0 LE K0 and K0 LE D0 D0 A LE DppA0 Mechanical interlock Fitted as standard on starters LE K and LE D0 D () Example: LE D0FA0 LE D0 to D0 A Other versions Possible combinations of variants. 0 Schemes : page / /

35 Dimensions Star-delta starters. to kw, without isolating device Dimensions LE K0, K0 0 0 LE D0 D c 0 LE D0 and D0 c Standard version. Variant A0 Variant A0. LE D0 D0 a - b () b +, b - 0 b - c c c +, a - 0 a a +, c c LE a b LE D0 D, D0 Standard version 0 D Standard version 0 Variant A0 D Variant A0 Variant A0 D Variant A0 Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom PG ISO PG ISO LE D0 D x 0 or x or x or x 0 LE D0 x x x, x and x LE D0 x x 0 x, x and x x 0 or x or x or x 0 x, x 0 and x x 0, x 0 and x LE D0 x x 0 x and x x 0 and x 0 LE K x and x x 0 x and x x 0 0 References : pages / and / Schemes : page / /

36 Schemes Star-delta starters. to kw, without isolating device Schemes LE K0 and K0 L L L A U V W O KM KM KM U V W U V W I KM KM KM KM U V W Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end). T B A A T KM A A Y A A A KM KM A L LE D0 D0 LE D0 D LE D0 D0 L L L A A U V W O KM KM KM I KM Remote control I KM U U V V W W U V W Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end). B KM KM KM KM KM Note : A A Y A A L A KM KM KM KM A B KM KM KM A A Y A A KM KM A KM KM L A LE D and D0 L L L U V W A KM KM KM U U V V W W U V W Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end). B Remote control l Connections A B 0 V, 0 V, 0 V LD0 and D L Neutral LE D to D0 L Neutral terminal 0 V, 00 V, V, 0 V All products L L Other voltages LE D0 D Terminal Terminal LE K and LE D0 D0 Direct connection F KM KM KM KM KM A A Y KM KM A A L KM KM KA A A KA KM A A 0 References : pages / and / Dimensions : page / /

37 Characteristics, references Star-delta starters (). to kw with isolating device Characteristics Conforming to standards IEC 0-- and IEC 0-, VDE 00-0, EN 0 Degree of protection conforming to IEC 0 IP : LE D0 D IP : LE D D0 Ambient air temperature Operation: - to + 0 C Operating positions Material References Same as that of the contactors Polycarbonate (): LE D Sheet steel: LE D Maximum operating rate: 0 starts/hour. Maximum starting time: 0 seconds. An LA DS timer imposes a delay of 0 ms ± ms on the delta contactor at the Standard power ratings of squirrel cage motors. Mains voltage - Delta connection 0 V 0 V 00 V V 0 V by the customer Size Type am Basic reference, to be completed by adding the voltage code () Weight kw kw kw kw A kg... 0 x 0 LE D0pp x LE Dpp.00. x 0 LE Dpp.0 LE Dpp x LE Dpp.0. x 0 LE D0pp.00 0 x LE D0pp LE D0pp.00 pages /0 () Avoid placing this material in contact with harsh substances (detergents, chlorine solvents, Volts /0 Hz B D E F FE M P U Q V N R 0 Dimensions: page / Schemes: page / /

38 References (continued) Star-delta starters. to kw, with isolating device Description The standard version comprises: b LE D0 D: v green Start button I, v red Stop/Reset button O. b LE D D0: v no pushbuttons on cover Protection Power circuit Control circuit LE D0 and D -pole isolating device + additional pole LE D LE D0 -pole isolating device + circuit-breaker GB CB0 LE DppA0 Variants (pre-assembled) Description Application the starter reference () No pushbuttons on cover LE D0 D A0 green Start button I red Stop/Reset button O LE D D0 A0 blue Reset button R LE D0 LE D0 A0 neutral terminal LE D0 LE D0 A LE DppA0 Mechanical interlock Fitted as standard on starters LE D0 D LE D D0 A () Example: LE D0FA0 0 Dimensions: page / Schemes: page / /

39 Dimensions Star-delta starters. to kw, with isolating device Dimensions LE D0 D LE D c 0 0 c Standard version. Variant A0 Variant A0. LE D0 D0 a- b () b+, b-0 b- xmx c a-0 a a+, LE a b c D0, D D Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom PG ISO PG ISO LE D0 D x 0 or x or x or x 0 LE D x x x, x and x LE D0 x x x, x and x LE D0 x x 0 x, x and x x 0 or x or x or x 0 x 0, x and x x 0, x and x x 0, x 0 and x LE D0 x x 0 x and x x 0 and x 0 0 References : pages / and / Schemes : page / /

40 Schemes Star-delta starters. to kw, with isolating device Schemes LE D0 D Q /L /L /L A Q Q KM KM KM U V W O l KM U V W KM U U V V W W Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end) B KM KM KM A A A A KM KM KM KM A A LE D D0 Q /L /L /L KM KM KM U V W A F Q U V W U V W Remote Ð S control l KM KM U V W Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end) B KM KM KM A A A A KM KM KM KM A A Connections A B 0 V, 0 V, 0 V LE D0 and D L Neutral LE D LE D0 L Neutral terminal 0 V, 00 V, V, 0 V All products L L Other voltages LE D0 D Terminal Terminal LE D D0 Direct connection 0 References : pages / and / Dimensions : page / /

41 References Replacement parts for starters without isolating device 00_ Heads for Start and Stop/Reset pushbuttons Description For use on Unit reference Weight kg Flush, green I () LE D0...D ZB AA _ ZB AA Projecting, red O () LE D0...D ZB AL 0.0 Adaptation kit for head ZB AL LE D0 and D LAD LE D...D LAD ZB AL Heads for Reset pushbuttons Flush, blue R () LE D0...D ZB AA _ + ZBA () 0.00 Adaptation kit for head ZB AA0 + ZBA LE D0 and D LAD LAD 0 LE or LE D...D LAD LE, LE, LE or LE D0...D LAD T _ Heads for selector switches -position stay put LE D0...D ZB AD _ ZB ADp -position stay put LE D0...D ZB AD 0.0 -position spring return to centre LE D0...D ZB AD 0.0 Contact blocks N/O spring return LE D0...D ZEN L _ N/C spring return LE D0...D ZEN L 0.00 Mounting for contact block LE D0 and D LAD LEp D...D () LAD LAD 0 /0

42 References (continued) Replacement parts for starters without isolating device Empty enclosures for D.O.L. starters without isolating device Designed for use with Head(s) mounted on cover Reference Weight kg LE D0 and D Without DE DSA DE DSA DE DSA0 projecting red head O DE DS 0.00 switch DE DSA 0.00 DE DSA0 LE D...D Without DE DSA DE DSA DE DS projecting red head O DE DS 0.00 switch DE DSA 0.00 DE DSA 0 /

43 References Star-delta starters () 0 to kw, without isolating device Star-delta starters Maximum operating rate: starts/hour. Maximum starting time: 0 seconds Standard power ratings of squirrel cage motors Mains voltage - delta connection Basic reference, to be completed by adding the voltage code () () Weight 0 V 0 V V 0 V kw kw kw kw kg LE Fpp LE Fpp LE Fpp LE F0pp LE F00pp.000 Enclosure LE F F00 Metal, degree of protection IP No pushbuttons on cover LE F F00 LE Fppppp Connections LE F F00 Pre-wired power and control circuit connections Variants (pre-assembled) Description green Start button I red Stop/Reset button O For use on LE F F00 to the starter reference() A0 pages / and / Volts 0 0/ / /0 Hz E F M P U Q V N For other voltages, see pages /0 () Example: LE FMA0 Other versions Possible combinations of variants. 0 Dimensions : page / Schemes : page / /

44 Dimensions, schemes Star-delta starters 0 to kw, without isolating device Dimensions LE Fppp a- b () b+, b-0 b- xmx c c a-0 a a+, LE a b () c c Knock-outs or blanking plugs for cable glands F, F Type of enclosure At top At bottom F LE F, F x P x P and x P F0, F LE F 00 Schemes LE Fppp L L L F KM: KM KM KM U U V V W W U U V V W W Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end) F O Remote control l KM KM KM KM () () KM KM KA F KM A KM A KA A KM A KM: A A A A Note : 0 References : page / /

45 References Equipment for control in utilisation category AC-() (), without isolating device 0 References Operational current up to Minimum c.s.a. of phase conductors Fuses to be am gg For use with relay LR D or kit LA D (to be ordered separately) Basic reference, to be completed by adding the voltage code () Weight A mm A A kg. LA D () LE Dpp LR D () LE Dpp 0.0. LR D () LE Dpp.0 LE D LA D0 () LE Dpp LE D0ppA0 ().0 0 LR D () LE D0pp.0 LE DppA0 () 0 LR D () LE Dpp LR D () LE D0pp.0 LE D LE D0ppA0 ().0 Enclosure LE D Double insulated, degree of protection IP LE D Double insulated, degree of protection IP LE D0...D0 Metal, degree of protection IP Control ( pushbuttons mounted on enclosure cover) No pushbuttons on cover LE D D0 LE DpppppA0 green Start button I red Stop/Reset button O Connections LE D D0 Pre-wired control circuit connections to walls, ceilings, in cable racks or ducting, laid singly, ambient temperature y () Order the required LR D () Control circuit voltage 0/0 Hz 0/0 V (code M) or 0/00 V (code Q () As protection is provided by type gg fuses only, the Stop function normally provided by the thermal overload relay (where am type fuses are used) can be obtained by means of kit LA Dpp 0 Dimensions : page / Schemes : page / /

46 References (continued) Equipment for control in utilisation category AC-() (), without isolating device Variants (pre-assembled) Description Application the starter reference () No pushbuttons on cover LE D and D A0 blue Reset button R LE D D0 A0 green Start button I and red Stop button O with N/C contact (for distribution circuits without thermal overload relay) LE D and D A0 -position selector switch O-I ( O : Stop; I : Manual Start) blue Reset button R Knock-outs for x mm plastic cable glands (instead of x mm plastic glands) LE D LE D A A0 neutral terminal (for -phase + N circuits) LE D D0 A Accessories (for customer assembly) Description Start pushbutton latching device for stay put operation (Start-Stop) Kits to provide Stop function For use on Reference Weight kg LE D D LA D LE D LA D 0.00 LE D LA D Miniature control circuit fuse holder size x 0, A/0 V Fuse supplied LE D LA D 0.00 LE D LA D 0.0 Pilot light with neon bulb, red lens and locking ring 0 V LE D and D LA D V LE D and D LA D , V LE D and D LA D 0.00 front-mounting block of auxiliary contacts, LE D D0 LA DNpp in cable racks or ducting, laid singly, ambient temperature y () Order the required LR D Example: LE DMA0 Other versions Possible combinations of variants. 0 Schemes : page / /

47 Dimensions D.O.L. starters and equipment, without isolating device Dimensions LE D LE D LE D0, D LE D0 0 0 () 0 c () 0 for LE Dppppp Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom LE D x P x P LE D x P and x P x P LE D0 and LE D x P and x P x P and x P LE D0 x P and x P x P and x P 0 References : pages / and / Schemes : page / /

48 Schemes D.O.L. starters and equipment, without isolating device Schemes D.O.L. starters and equipment for control in category AC- LE D D0, LE DpppppA0 LE D KM /L U /L LE D D0 V W /L KM/ N I KM/ O KM KM A A LE DpppppA0, LE DpppppA0 KM/ KM/ l N KM/ O KM KM A A Remote control N KM/ O l KM KM A A 0 References : pages / and / Dimensions : page / /

49 References Equipment for control in utilisation category AC- () (), with isolating device References Operational current up to Minimum c.s.a. of phase conductors by the customer Size Type am gg For use with relay LR D or kit LA D (to be ordered separately) Basic reference, to be completed by adding the voltage code () Weight A mm A A kg. 0 x LA D0 () LE Dpp.0 LE D.. 0 x 0 LR D () LE Dpp x 0 LA D0 () LE Dpp x LR D () LE Dpp x 0 LE D0ppA0 ().0 0 x 0 LR D () LE D0pp.0 LE D0 x LE DppA0 ().0 x 0 LR D () LE Dpp.0 0 x 00 LR D () LE D0pp () x 00 LE D0pp ().00 Enclosure LE D and D Double insulated, degree of protection IP Control ( pushbuttons mounted on enclosure cover) LE D0 D0 Metal, degree of protection IP LE D D green Start button I red Stop/Reset button O No pushbuttons on cover Isolating device with external operator LE Dppppp A0 LE D0 LE D and D LE D0 D0 -pole isolator + additional pole -pole isolator and circuit breaker GB CB0 Connections LE D D0 Pre-wired power and control circuit connections in cable racks or ducting, laid singly, ambient temperature y () Order the required LR D () Control circuit voltage 0/0 Hz 0/0 V (code M) or 0/00 V (code Q () As protection is provided by type gg fuses only, the Stop function normally provided by the thermal overload relay (where am type fuses are used) can be obtained by means of kit LA D0 0 Dimensions : page /0 Schemes : page / /

50 References (continued) Equipment for control in utilisation category AC- () (), with isolating device Variants (pre-assembled) Description For use on the starter reference() No pushbuttons on cover LE D and D A0 blue Reset button R LE D D0 A0 green Start button I and red Stop button O with N/C contact (for distribution circuits without thermal overload relay) LE D and D A0 neutral terminal (for -phase + N circuits) LE D D0 A Accessories (for customer assembly) Description Start button latching device for stay put operation (Start-Stop) Kit to provide Stop function For use on Reference Weight kg LE D D LA D LE D and D LA D Miniature control circuit fuse holder size x 0, A/0 V Fuse supplied Pilot light with neon bulb, red lens and locking ring LE D and D LA D V LE D and D LA D V LE D and D LA D , V LE D and D LA D 0.00 front-mounting block of auxiliary contacts, LE D D0 LA DNpp 0.00 in cable racks or ducting, laid singly, ambient temperature y () Order the required LR D () Example: LE DMA0 Other versions Possible combinations of variants. 0 Schemes : page / /

51 Dimensions D.O.L. starters and equipment, with isolating device Dimensions LE D, D LE D0, D c c 0 0 c c () LE c c D D () c c for LE Dppppp b G a H LE D0 a- b () b+, b-0 b- xmx c c a-0 a a+, Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom LE D x P x P LE D x P and x P x P LE D0 x P and x P x P and x P LE D x P and x P x P and x P LE D0 x P and x P x P and x P 0 References : pages / and / Schemes : page / /0

52 Schemes D.O.L. starters and equipment, with isolating device Schemes D.O.L. starters and equipment for control in category AC- LE D D0, LE DpppppA0 LE D and D Q KM /L /L /L Q/ 0 Q N l Q O KM KM A U V W Q/ A LE D0 and D Q/ l F Q O KM LE D0, LE DpppppA0 and DpppppA0 Q/ F Q Remote control O l KM N Q/ KM A A N Q/ KM A A 0 References : pages / and / Dimensions : page /0 /

53 References integral contactor breakers and reversing contactor breakers, for customer assembly Empty metal enclosure Type of enclosure Degree of protection IP with drillings for door interlock mechanism (interlock not supplied), for customer assembly () For use on integral Door interlock mechanisms (IP ) Type Non-adjustable Reference Weight kg LD LD or LD LD DE LT.0 For use on enclosure DE LT (LD) Colour of knob Reference Weight kg Red LA LC Black LA LC 0.00 DE LT DE LT (LD) Red LA LC Black LA LC 0.00 () cable glands (to be ordered separately): for number and diameters, see page / 0 Dimensions : page / /

54 Dimensions, mounting of accessories integral contactor breakers and reversing contactor breakers, for customer assembly Empty metal enclosure, degree of protection IP 0 Number of blanked-off cable entries for addition of cable glands At Cable Ø For cable gland top bottom min. max. N Type 0 M 0 M Non-adjustable door interlock mechanisms LA LCp and LA LCp For mounting on LD LDp0 and LD LDp0 () LD LDp0 LD LDp (LD) (LD) Door drillings 0 0 References : page / /

55 Characteristics integral contactor breakers and reversing contactor breakers Type integral Number of poles Rated operational current (Ie) A in AC- Rated operational voltage (Ue) V 0 Electrical durability, AC- at V. million operating cycles Mechanical durability at Uc million operating cycles Maximum operating rate a 00 operating cycles/hour at ambient temperature y C c With converter 00 operating cycles/hour Environment Conforming to standards IEC: 0-, 00-, 0-, 0--, 0-- VDE: 000, 00, 0, 00, 0,, 00 BS:,, NEN, NBN Protective treatment Ambient air temperature around the device Vibration resistance Permissible acceleration Shock resistance Permissible acceleration ASE, ASEFA, ASTA, BV, CSA, DEMKO, DNV, GL, NEMKO, NKK, ÖVE, RINA, SCC, SETI, UL, USSR, LROS, PTB, SEMKO TH a Operation C Storage C c () Operation C Storage C Hz Energised state: gn De-energised state: gn Impulse duration: ms Energised state: gn De-energised state: gn Degree of protection Conforming to IEC and IP 0B Conforming to VDE 00 Flame resistance Conforming to IEC 0--, NF C 0- and the requirement of -- (JO NC of st and //) and conforming to UL - V0 and NF T -0 Maximum operating altitude Without derating m 000 Operating positions (without derating) In relation to normal vertical mounting plane From main axis (left-right tilt) Control circuit characteristics Rated control circuit voltage (Uc) Voltage limits at y C Average consumption at 0 C and at Uc a 0 Hz V 0 a 0 Hz V 00 c With converter V,, 0 Operating 0.. Uc Drop-out Uc a Inrush VA (0 Hz), 0 (0 Hz) Sealed VA (0 or 0 Hz) c () Inrush W 00 for 0 ms Sealed W Heat dissipation a 0 Hz W (0 Hz) (0 Hz) Operating time () at 0 C and at Uc a 0/0 Hz C ms O ms 0 c () C ms 0 O ms () The closing time C is measured from the moment the coil supply is switched on to initial 0 References : pages / to / / Dimensions : page /0 Schemes : page /

Motor circuit-breakers

Motor circuit-breakers Thermal-magnetic motor circuit-breakers type GV2-M GV2-M Thermal-magnetic motor circuit-breakers GV2-M Pushbutton control Standard power ratings Setting Magnetic Thermal Reference Weight of 3-phase motors

More information

Pendant control stations 6

Pendant control stations 6 Characteristics 6 Environment Conformity to standards EN/IEC 6097-5-1 EN/IEC 600-, UL 508, CSA C- n EN/IEC 6097-5-5 and EN/ISO 850 for versions with trigger action Emergency stop Product certifications

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Safety detection solutions

Safety detection solutions Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

Catalog January. Heavy industrial power applications Motor contactors and starters

Catalog January. Heavy industrial power applications Motor contactors and starters Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

D-Line Contactors, Overload Relays and Accessories

D-Line Contactors, Overload Relays and Accessories D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

Tmax MCCBs. Molded case circuit breakers. Tmax

Tmax MCCBs. Molded case circuit breakers. Tmax Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high

More information

Circuit Breakers. Next Generation of Protection Capabilities

Circuit Breakers. Next Generation of Protection Capabilities Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW ADS8 IP54 Direct-On-Line Starter Technical Focus Replaces ADS7 Rated up to 9kW New ADS8 Motor Starter The new ADS8 range of motor starters replaces the successful ADS7 range which was introduced 20 years

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

Safety dialogue solutions

Safety dialogue solutions General Presentation Emergency stop trip wire switches Emergency stop trip wire switches are designed to: b avert hazards (dangerous phenomena) at the earliest possible moment, or to reduce risks which

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Products and solutions for lifting systems

Products and solutions for lifting systems Products and solutions for lifting systems 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters founded

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

PSR The compact range Description

PSR The compact range Description Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Technicaldata General

Technicaldata General Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for. The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved

More information

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide - long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and

More information

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A Low voltage electrical distribution Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A User manual 09/2009 User manual for circuit breakers and switch-disconnectors Masterpact

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, Flameproof Enclosure Series 8264. www.stahl. > Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) 4 NC1 D09-D18 NC1 -D32 US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) Standards: UL508, CSA C22.2, IEC 60947, and CE Marked Integral DIN Rail & Base Mounting in One Compact

More information

Technical catalogue. Modular DIN rail components Installation contactors

Technical catalogue. Modular DIN rail components Installation contactors Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a

More information

Products and solutions for pumping, irrigation and piping

Products and solutions for pumping, irrigation and piping Products and solutions for pumping, irrigation and piping 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric

More information

Control Panel Technical Guide

Control Panel Technical Guide Control Panel Technical Guide How to select the appropriate motor starters for your HVAC & R* equipments * Heating, Ventilation, Air conditioning & Refrigeration Many machines can be used in a HVAC&R installation

More information

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5 Eaton Wiring Manual / Page Overview - ON-OFF switches, main switches, maintenance switches - Changeover switches, reversing switches - (Reversing) star-delta switches - Multi-Speed Switches - Interlock

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

9 Control Equipment. Control Button Series 8082

9 Control Equipment. Control Button Series 8082 9 Control Equipment Control Button 01706E00 contact elements enable contact blocks to be combined easily; using an actuator in the 8602 series, regardless of the type of actuator, up to 4 contact elements

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Power Generation. Power Control PCL System Generator Set Control

Power Generation. Power Control PCL System Generator Set Control Power Generation Power Control PCL System Generator Set Control Solid State Control The Power Control PCL system uses the latest solid state control technology. Designed for the budget-conscious installation

More information

Mureva Assembly surface mounted wiring devices

Mureva Assembly surface mounted wiring devices 1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label

More information

THERMAL RELAYS, MOTORSTARTERS

THERMAL RELAYS, MOTORSTARTERS THERMAL RELAYS, MOTORSTARTERS MH mini thermal relay plugged version H0K thermal relay with adapter H0K thermal relay plugged version T I thermal relay plugged version H thermal relay with current transformer

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

SMS 4 / SMS 5 safety mat Product information

SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data. Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,

More information

Wiring diagrams. Compact NSX. Contents

Wiring diagrams. Compact NSX. Contents Compact NSX Wiring diagrams Contents Functions and characteristics A-1 nstallation recommendations B-1 Dimensions and connection C-1 Compact NSX100 to 630 Fixed circuit breakers D-2 Plug-in / withdrawable

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC

More information

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps

More information

THE ADVANTAGES ARE YOURS

THE ADVANTAGES ARE YOURS THE ADVANTAGES ARE YOURS The new switches/discrepancy switches "R0-DR0" have special characteristics that make them very different from the normal switches on the market. Listed below are some of the many

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Catalog. Modular DIN rail components Installation contactors

Catalog. Modular DIN rail components Installation contactors Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to

More information

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications 077 Series Analogue Features Monitors and controls any variable which can be converted to an A.C. or D.C. signal. Rugged, shock and vibration resistant design Indicator, relays and power unit in one housing

More information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

more than a breaker it s a breakthrough Compact NSX

more than a breaker it s a breakthrough Compact NSX Compact NSX, more than a breaker it s a breakthrough Compact NSX 100-630 A Intelligent outlook Today, we are living in an increasingly booming and fast changing world where energy is key. More than ever,

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

ACS-30-EU-EMDR-10-MOD

ACS-30-EU-EMDR-10-MOD Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature

More information

General Informations 2 Technical data 3 Basic designs 4-8

General Informations 2 Technical data 3 Basic designs 4-8 Contents Page General Informations 2 Technical data 3 Basic designs 4-8 Cam Switches On-Off switches, Changeover switches 9-12 Star-Delta switches 13-15 Multi speed switches 16-20 Control switches 21-23

More information

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Control Devices Catalogue. Control Devices. Preferred and Standard Products Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface

More information

Data Sheet. Electro-mechanical counters Hengstler 800 series

Data Sheet. Electro-mechanical counters Hengstler 800 series Data Pack D Issued March 00 504897 Data Sheet Electro-mechanical counters Hengstler 800 series The 800 series totalising and predetermining batch counters, manufactured by Hengstler, is available from

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W SCHRACK-INFO Any mains connection If using 4-pole. switches with 3 or 2-poles, ensure connection acc. to assembly instructions

More information

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO) SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY

More information

SKR - industry relay

SKR - industry relay SKR - industry relay the universal relay SKR the time module STM the socket The strengths of the SKR industry relay lie in the mature and thoughtout construction. Over-average contact safety and life time,

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

Preventa Machine Safety Products

Preventa Machine Safety Products Preventa Machine Safety Products Catalog 2009 200 Supplement Safety Relay Modules 2 Contents Preventa safety relay modules Selection guide 2 Electrical Ratings 6 Types XPSAC and XPSAXE For Emergency stop

More information

Bimetallic Overload Relay Specifications

Bimetallic Overload Relay Specifications Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions

More information

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

VLT Series 3500 Adjustable Frequency Drive Instruction Manual Adjustable Frequency Drive Instruction Manual VLT Series 3500 Instruction Manual 175R5237 - Document Version 5.00 This manual applies to all VLT Series 3502-3800 Adjustable Frequency Drives with software

More information

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components

More information

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 8-poles Overview Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

Sentron Series Circuit Breakers

Sentron Series Circuit Breakers Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of

More information

PNOZsigma - Base units

PNOZsigma - Base units PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable

More information

3K Load-Break Switches The Program for Safety and Performance. sentric

3K Load-Break Switches The Program for Safety and Performance. sentric 3K Load-Break Switches The Program for Safety and Performance sentric Whether for reliable switching and isolation under load, or for protection against overload or short-circuits our 3K range of load-break

More information

Comparison of NEMA and IEC schematic diagrams

Comparison of NEMA and IEC schematic diagrams Cross-Reference MZ081001EN Comparison of NEMA and IEC schematic diagrams General With the increasing emphasis on globalization, many industries are now looking to all parts of the world to produce, market,

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

3 - Cam switches. Contents 0. Complete switches, 10 A. Complete switches, 12 and 20 A. Adaptable sub-assemblies, 12 and 20 A

3 - Cam switches. Contents 0. Complete switches, 10 A. Complete switches, 12 and 20 A. Adaptable sub-assemblies, 12 and 20 A Contents - Cam switches Selection guide............................................. page / Complete switches, A b Front mounting by Ø or Ø mm, with x mm front plate... page / v Switches and stepping switches..............................

More information