Safety dialogue solutions

Size: px
Start display at page:

Download "Safety dialogue solutions"

Transcription

1 General Presentation Emergency stop trip wire switches Emergency stop trip wire switches are designed to: b avert hazards (dangerous phenomena) at the earliest possible moment, or to reduce risks which could cause injury to persons or damage either to machines or work in progress, b be tripped by a single human action when a normal Emergency stop function is not available, b trip in the event of the trip wire breaking. Emergency stop trip wire switches are essential in premises and on machines that are potentially dangerous when in operation. The operator must be able to trigger the stop instruction at any point within their working area. Application examples: woodworking machines, shears, conveyor systems, transfer machines, printing machines, textile machines, rolling mills, test laboratories, paint shops, surface treatment works. Installation Typical installation 0 Fixing support First cable support Turnbuckle Notes regarding installation Pulley supports and pulleys End spring grips Switch adjustment Emergency stop b All XY CH/CE/CB trip wire switches can be fitted with a pilot light to indicate their tripped condition. b tension adjustment can be performed using: v a turnbuckle (to be ordered separately, see page /), v a tensioner (integrated in certain XY CH models, see page /), v a tensioner (to be ordered separately, see page /) for mounting on XY CE models. b This adjustment is simplified by: v a cable tension indicator that is available on all models XY CH, v the availability of versions with a cable tension indicator window by stating its reference on the order form (see page /0). Example: reference XY CEA0 becomes XY CED0. b The use of an end spring is strongly advised for conveyor system applications to ensure operation of the Emergency stop in the event of the cable being pulled towards the switch. b It is essential that pulleys be used with trip wires that deviate from a straight run, i.e. angled to form a protected zone. b Important: switches XY CB must not be used if the installation requires that the trip wire be angled. Switches XY CH and XY CE can be used if the installation requires that the trip wire be angled. In this case, the total sum of the angles through which the trip wire bends must not exceed 0 (For further information on instructions to be adhered to, please refer to the installation manual). page / / s: page / page /

2 General (continued) Main features Trip wire expansion and contraction: d Positive operation: running condition Latching: stop instruction given (tripped) Resetting: stop condition (awaiting reset/restart) The switches incorporate positive opening operation contacts, the tripping of the switch being made with positive action. The switch latches in the tripped position (N/C safety contact(s) open). The function of the N/O contact is purely for signalling. The switches incorporate a reset button, which re-closes the safety contact(s). Restarting of the machine must only be achieved by manual operation of a control device within the machine start circuit, remote to the trip wire switch. Temperature variations likely to be encountered in the protected zone will obviously cause the trip wire to expand or contract. To enable instant verification that the trip wire is at its correct tension (and for making any necessary adjustments), trip wire switches XY CH and XY CE incorporate a trip wire tension indicator. d (mm) Tripping force: F Tripping deflection: f The tripping force F is the force necessary on the trip wire to cause the switch to trip. The tripping deflection f is the distance that the trip wire has to be deflected from its taut position to the point at which the switch trips. f Adjustment values (with end spring) Standards For Emergency stop trip wire switches E: the adjustment values depend on the positions of the cam located inside the switch. Adjustment is made by rotating the cam after the switch has been installed. Each notched position of the cam is referenced by the letters A to F, and the selected letter is visible through a viewing port. Temperature range: < C. Type Position Max. length End spring Average tripping deflection values f and tripping forces F for a distance of m between cable supports and cable used of of Force F (dan) Deflection f (mm) for: cam cable Standard Light Standard force Light force Ø. mm Ø mm Ø. mm Ø mm Ø. mm Ø mm Ø. mm Ø mm XY CH m XY CZ XY CE A 0 m XY CZ B C D E F XY CB 00 m XY CZ0. Trip wire switches XY CH, XY CE and XY CB meet all the requirements of the harmonised European standard EN/ISO 0:00, relating to Emergency stop devices. All the trip wire switches are e marked and supplied with an EC declaration of conformity. F 0 page / s: page / page / /

3 Characteristics Environment Conformity to standards Products XY CH, XY CE: EN/IEC 0--, EN/ISO 0:00, UL 0 and CSA C - n (with suffix H) XY CB: EN/IEC 0--, EN/ISO 0:00, CSA C - n (with suffix H) Machine assemblies XY CH, XY CE, XY CB: EN/IEC 00-, Machinery directive: //EC and //EEC, Work equipment directive: //EEC Product certifications XY CH: UL-CSA (with suffix H), CCC () XY CE: UL-CSA A00-Q00 (with suffix H), CCC () XY CB: CSA A00-Q00 (with suffix H) Protective treatment Standard version TC Special version TH Ambient air temperature For operation C Vibration resistance For storage C XY CH: 0 gn (0 0 Hz) XY CE: 0 gn (0 00 Hz) conforming to EN/IEC 00-- Shock resistance XY CH, XY CE: 0 gn (duration ms) conforming to EN/IEC 00-- Electric shock protection Class I conforming to EN/IEC 0 and NF C 0-00 Degree of protection XY CH, XY CE: IP XY CB: IP, contact housing IP, conforming to EN/IEC 0 and NF C 0-00 Mechanical life Length of protected zone (trip wire) Distance between cable supports entries See dimensions, page /. Contact block characteristics Rated operational characteristics Nominal thermal current Rated insulation voltage XY CH, XY CE (Emergency stop), XY CB: operating cycles XY CH: y metres, XY CE: y 0 metres, XY CB: y 00 metres and y x 00 metres m XY CH, XY CE: AC-: A00 or Ue = 0 V, le = A DC-: Q00 or Ue = 0 V, le = 0. A conforming to EN/IEC 0-- Appendix A XY CB: AC-: A00 or Ue = 00 V, le =. A DC-: Q00 or Ue = 00 V, le = 0. A conforming to EN/IEC 0-- Appendix A 0 A XY CH, XY CE: Ui = 00 V degree of pollution conforming to EN/IEC 0-, Ui = 00 V conforming to UL 0, CSA C- n XY CB: Ui = 00 V degree of pollution conforming to EN/IEC 0-, Ui = 00 V to CSA C- n Rated impulse withstand voltage XY CH, XY CE: Uimp = kv, XY CB: Uimp = kv conforming to EN/IEC 0- Positive operation N/C contact with positive opening operation conforming to EN/IEC 0-- Section Contact operation XY CH, XY CE (Emergency stop), XY CB: N/C + N/C or N/C + N/O Resistance across terminals y mω conforming to NF C -00 method A or EN/IEC 0- category Terminal referencing Conforming to CENELEC EN 00 Short-circuit protection XY CH, XY CE, XY CB: 0 A cartridge fuse type gg (gl) conforming to EN/IEC 0 Rated operational power (Electrical durability) Operating rate: 00 operating cycles/hour Load factor: 0. XY CH, XY CE Conforming to EN/IEC 0-- Appendix C Utilisation categories AC- and DC- a.c. supply a 0 0 Hz o Inductive circuit Millions of operating cycles 0, 0 V Ithe // V V XY CB Conforming to EN/IEC 0-- Appendix C Utilisation categories AC- and DC- a.c. supply a 0 0 Hz Power broken in VA () o Inductive circuit Voltage V 0 o VA Contact connection 0, 0A Current in A d.c. supply c Power broken in W () o Inductive circuit Voltage V 0 Voltage V 0 o W 0 o W () For million operating cycles. Screw clamp terminals Clamping capacity: min. x 0. mm, max. x. mm Minimum tightening torque: 0. N.m Maximum tightening torque:. N.m () Only products XY CH without pilot light and XY CE without pilot light or with, or 0 V pilot light are CCC and UL-CSA approved. page / / s: page / page /

4 s Latching Emergency stops (integrated turnbuckle, cable and end spring to be ordered separately) () Without pilot light Length of cable Colour of Reset Type of contact anchor point 00 XY CH0 y m Grey RAL 0 Grey RAL 000 () With pilot light (direct supply) y m Grey RAL 0 N/C + N/O XY CH0 () 0. By mushroom XY CH0 () 0.00 head By key operated (key n ) () By flush XY CH0 () 0.0 N/C + N/C XY CH0 () 0. XY CH0 () 0. By mushroom XY CH0 () 0. head By key operated (key n ) () XY CH0 () 0.0 N/C + N/O N/C + N/C V N/C + N/O N/C + N/C XY CH () 0. XY CH () 0. XY CH 0.00 XY CH 0.00 Latching Emergency stops (turnbuckle, cable and end spring to be ordered separately) () Without pilot light y 0 m () Grey RAL 0 N/C + N/O RH side XY CEA0 ().0 XY CEA0 ().0 00 N/C + N/C RH side XY CEA0 ().0 XY CEA0 ().0 XY CEA0 By key operated (key n ) () N/C + N/O N/C + N/C RH side XY CEA0 (). XY CEA0 (). RH side XY CEA0 ().0 XY CEA0 ().0 With pilot light (direct supply) y 0 m () Grey RAL 0 V, V, 0 V (bulb not included) 0 V (bulb not included) N/C + N/O N/C + N/O RH side XY CEA.0 XY CEA.0 RH side XY CEA.0 XY CEA.0 Other versions See order forms on pages / and /. XY CE with reset by Ø 0 mm mushroom head or with integral cable tensioner and support. Please consult your Regional Sales Office. () See separate components, page /. () Ø 0 spring return, mushroom head, key operated. Locking and key withdrawal in the rest (unactuated) position. () For ISO M0 threaded cable entry version, add H to the end of the reference selected. Example: XY CH0 becomes XY CH0H. () Only available on Emergency stop s Hp and XY CHp for standard, H and TK versions. () Available with window for viewing cable tension indicator, for adjustment whilst the cover is closed (see versions XY CEpDppp and XY CEpEppp on the order form, page /0. () ATEX version available (products for explosive atmospheres). To order, add EX to the end of the reference. Example: XY CEA0 becomes XY CEA0EX. 0 page / page / page / /

5 s (continued) Latching Emergency stops (end spring included, turnbuckle and cable to be ordered separately) () Without pilot light Length of cable Colour of Reset Type of contact anchor point y 00 m Blue From inside N/C + N/O XY CB0.0 RH side XY CB0.0 0 N/C + N/C XY CB0.0 RH side XY CB0.0 y x 00 m Blue From inside N/C + N/O XY CB0.0 XY CB0 With pilot light Length of cable Colour of b Direct supply y 00 m Blue From inside N/C + N/C Reset Supply voltage Type of contact anchor point V N/C + N/O XY CB0.0 XY CB.0 RH side XY CB.0 V N/C + N/O XY CB.0 RH side XY CB.0 y x 00 m Blue From inside V N/C + N/O V N/C + N/O XY CB.00 XY CB 0.00 b Supply via integral transformer () y 00 m Blue From inside V/ V N/C + N/O XY CB.00 RH side XY CB.00 0 V/ V N/C + N/O XY CB.00 RH side XY CB.00 y x 00 m Blue From inside V/ V N/C + N/O XY CB.00 0 V/ V N/C + N/O XY CB.00 0 () See separate components, page /. End spring XY CZ0 included. () Bulb DL CB00 included. page / / page / page /

6 Order form (specimen suitable for photocopying) Complete units, pre-assembled Customer Company Order N Delivery date Schneider Electric Industries SA Sales office - Subsidiary Co. Order N How to use this form: - indicate the number of Emergency stop switches required, - complete the basic reference. Number of identical Emergency stops XY CH Model Emergency stop (latching) Degree of protection IP (standard bellows) without tensioner IP (silicone bellows) without tensioner IP (standard bellows) with integral tensioner IP (silicone bellows) with integral tensioner Type of reset Emergency stop () Reset by spring return Flush Booted Mushroom head, Ø 0 Key operated mushroom head, Ø 0 (key n ) Key operated mushroom head, Ø 0 (key n ) Key operated mushroom head, Ø 0 () Contact block for Emergency stop function () Slow break N/C + N/O (N/O staggered) N/C + N/C Pilot light Without pilot light 0 With V direct supply pilot light With V direct supply pilot light With 0 V direct supply pilot light With 0 V direct supply pilot light /" NPT tapped cable entries H () ISO M0 tapped cable entries H Increased protective treatment against corrosion TK () () Opening of a circuit + mechanical latching in the open position. () Other key numbers: A 0E A E A A E E E () Emergency stop trip wire switches can only be fitted with contact blocks. () Only for versions without pilot light. For versions with pilot light, order an H version. () Protective treatment TK is only possible for switches with silicone bellows (XY CHpppTK, XY CHpppHTK...). 0 /

7 Order form (specimen suitable for photocopying) Complete units, pre-assembled Customer Company Order N Delivery date Schneider Electric Industries SA Sales office - Subsidiary Co. Order N How to use this form: - indicate the number of Emergency stop switches required, - complete the basic reference. Number of identical Emergency stops XY CE Model Emergency stop (latching) Anchor point on RH side, standard force Anchor point on, standard force Anchor point on RH side, light force Anchor point on, light force Degree of protection and cable tension indicator window IP (standard bellows) without cable tension indicator window IP (silicone bellows) without cable tension indicator window IP (standard bellows) with cable tension indicator window IP (silicone bellows) with cable tension indicator window A C D E Type of reset Emergency stop () Flush Reset by spring Booted return Mushroom head, Ø 0 Key operated mushroom head, Ø 0 (n ) Key operated mushroom head, Ø 0 (n ) Key operated mushroom head, Ø 0 () Contact block for Emergency stop function () Slow break N/C + N/O N/C + N/C N/C + N/O (compulsory with pilot light) () Pilot light Without pilot light 0 With --0 V direct supply pilot light. Bulb not included (provide for contact blocks) With 0 V direct supply, via integral resistor, pilot light. Bulb included (provide for contact blocks) () /" NPT tapped cable entries H () Increased protective treatment against corrosion TK () () Opening of N/C contact + mechanical latching in the open position. () Other key numbers: A 0E A E A A E E E () Emergency stop trip wire switches can only be fitted with contact blocks. () The use of a pilot light means selecting a switch fitted with N/C + N/O contacts: XY CEppp. () Replacement bulb: DL CE0. () For versions with pilot light, order an H version. () Protective treatment TK is only possible for switches with silicone bellows (XY CEpCpppTK, XY CEpEpppHTK...). 0 /0

8 s (continued) XY CZ0 XY CZ0 Separate components Description For use with Diameter mm Galvanised cables with red sheath XY CH, XY CE and XY CB Length m. 0. XY CZ XY CZ XY CZ XY CZ XY CZ0.00 XY CH and XY CE. XY CZ XY CZ XY CZ XY CZ XY CZ0 Description Type For use with Sold in Unit reference lots of Tensioner XY CE only XY CZ0 0.0 Turnbuckles M x 0 + locknut All models () XY CZ XY CZ 00 XY CZ0 M x 0 + locknut All models () XY CZ grips Single Ø to mm 0 XY CZ Double Ø to mm 0 XY CZ 0.0 Clamp Ø. mm 0 XY CZ 0.00 Ø mm 0 XY CZ supports Fixed All models 0 XY CZ Swivelling All models XY CZ0 0.0 Pulley support XY CH and XY CE XY CZ Pulley Ø mm max. XY CH and XY CE XY CZ end protectors Ø. mm 0 XY CZ Ø mm 0 XY CZ XY CZ0 XY CZ0 00 XY CZ0 XY CZ0 End springs XY CH XY CZ0 0.0 XY CE and XY CB XY CZ Mounting kits Contents For use with diameter tensioner XY CZ0 + bracket galvanised cable + cable grip XY CZ + end spring XY CZ0 Length of cable mm m XY CE XY CZ 0. XY CH. 0 XY CZ0 0. XY CZ 0. XY CZ0 galvanised cable XY CE. XY CZ 0 + cable grips XY CZ + turnbuckle XY CZ0 + cable support XY CZ0 + cable end protectors XY CZ0 XY CE and XY CB + end spring XY CZ0. 0 XY CZ galvanised cable XY CE XY CZ.0 + cable grips XY CZ + turnbuckle XY CZ0 + cable support XY CZ0 + cable end protectors XY CZ0 + end spring XY CZ0 0 XY CZ0.0 XY CZ Documentation Description For use with Installation manual XY CH and XY CE XCOM 0.00 () Emergency stop trip wire switches XY CHppp and XY CHppp incorporate a cable tensioner as standard. Therefore, there is no need to order a turnbuckle. 0 page / page / page / /

9 s (continued) Replacement parts Description Type Reset (blue), spring return for XY CH and XY CE Flush with R marked on push ZA BA 0.00 Booted ZA BP 0.0 Mushroom head, Ø 0 ZA BC 0.0 Key operated mushroom head, Ø 0 (key n ) ZA BS Key operated mushroom head, Ø 0 (key n ) ZA BS Keys for reset button N Q N Q Pilot light head assembly Orange, for XY CH and XY CE ZA BV0 0.0 Pilot light lens Orange, for XY CH and XY CE ZB BV Fixing nut Black plastic nut for head ZA B ZA BZ Fixing nut tightening tool Black plastic socket wrench for fixing nut ZA BZ0 ZA BZ Pilot lights With bulb DL AAppp included Orange, for XY CH V XY CZ00 () 0.0 V XY CZ00 () V XY CZ00 () 0.0 XY CZpppp 0 V XY CZ00 () 0.0 Red, for XY CB V 00 KPR 0. V 00 KPR 0. 0 V 00 KPR KPpR Description Type Sold in lots of Incandescent bulbs Screw base fitting for XY CH 0 V 00 KPR 0.0 Unit reference V - W 0 DL AA V - W 0 DL AA V - W 0 DL AA V - W 0 DL AA XY CZ0 Packet of collars Dust and damp protecting bellows BA s base fitting for XY CE and XY CB V -. W 0 DL CE V -. W 0 DL CE BA s base fitting for 0 V -. W 0 DL CE XY CE BA s base fitting for XY CB 0 V and 0 V V -. W 0 DL CB For mounting DL AA and DL AA0 XY CZ0 0.0 bulbs in pilot lights XY CZppp For XY CE Polychloroprene XY CZ0 0.0 Silicone XY CZ For XY CH Polychloroprene XY CZ0 0.0 Silicone XY CZ XY CZ0 Adaptor For XY CB ISO M0 DE RP () Only for use as replacement parts for switches pre-fitted with pilot lights. CCC and UL-CSA approvals no longer apply if a pilot light XY CZppp is mounted on Emergency stops XY CH.. page / / page / page /

10 Dimensions XY CH Accessories Without pilot light With pilot light XY CZ0 () () (), (), M () () 0 () 0 () () 0 () 0 () () Maximum extension. () Tapped entries for n (Pg.) cable gland. For ISO M0 the reference becomes XY CHpppppH. () mm: V and V versions. mm: 0 V and 0 V versions. XY CE XY CEpAppp, XY CEpCppp 0 () () () Ø 0 0 () XY CEpAppp + XY CZ (tensioner + bracket) XY CZ0 Ø () plain holes for n (Pg.) or ISO M0 cable gland. () Maximum extension. Ø: elongated holes Ø mm. XY CB Without pilot light () With pilot light () 0 () 0 xø xø () () = 0 = 0 () () access points for operating cable. () + for opening cover. () tapped entry for n (Pg.) cable gland. For ISO M0 use adaptor DE RP0. () 0 = 0 = 0 0 page / page / s: page / /

Pendant control stations 6

Pendant control stations 6 Characteristics 6 Environment Conformity to standards EN/IEC 6097-5-1 EN/IEC 600-, UL 508, CSA C- n EN/IEC 6097-5-5 and EN/ISO 850 for versions with trigger action Emergency stop Product certifications

More information

Safety detection solutions

Safety detection solutions Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

General 1-2-Opto-electronics Safety Switches 4-Emergency

General 1-2-Opto-electronics Safety Switches 4-Emergency General 1-2-Opto-electronics Safety Switches 4-Emergency Logic Power The Lifeline 4 cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range 6.1 6.1.1 6.1.1.1. 312 Schmersal -10 0 10 20 30 40 50 60 70 T [] C

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range 6.1 6.1.1 6.1.1.1. 312 Schmersal -10 0 10 20 30 40 50 60 70 T [] C .1.1.1 One-side operation ZS 71 range 40 30 ø10 10 53,5(63)* 6 8 18 24 105 33 56 12 22 M20x1,5 52 17,5 42 15 Features To EN 418 / IEC 60947-5-5 Metal enclosure 2 contacts Small body 2 cable entries M20

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Characteristics XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Complementary Detection system Kit composition [EAA] effective aperture angle Emission Main Range of product Product or

More information

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry. y HS5D First in the Industry Miniature Interlock Switches First in the Industry Head Removal Detection Function for Safer Performance (*based on IDEC research, July 09) New Generation Miniature Interlock

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

Explosion proof enclosures

Explosion proof enclosures 1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Givare NC-SRS 280 och 880

Givare NC-SRS 280 och 880 Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

Preventa Machine Safety Products

Preventa Machine Safety Products Preventa Machine Safety Products Catalog 2009 200 Supplement Safety Relay Modules 2 Contents Preventa safety relay modules Selection guide 2 Electrical Ratings 6 Types XPSAC and XPSAXE For Emergency stop

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color) Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

9 Control Equipment. Control Button Series 8082

9 Control Equipment. Control Button Series 8082 9 Control Equipment Control Button 01706E00 contact elements enable contact blocks to be combined easily; using an actuator in the 8602 series, regardless of the type of actuator, up to 4 contact elements

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket Technical Datasheet SNK636D00 Catalogue Page SNK636S00 ZS-SF-T Screw Clamp Terminal Blocks For x 0 and x fuses - with test socket - Protect your circuit with x and x0 fuse terminal blocks (fuse not supplied

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED) NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Technicaldata General

Technicaldata General Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description

More information

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

Pendant control stations 6

Pendant control stations 6 References Empty enclosures 0 XACA0 Empty enclosures Description Enclosure comprising: - the enclosure, - internal mounting plate, - protective cable sleeve, - internal cable clamp, - suspension ring,

More information

Technical catalogue. Modular DIN rail components Installation contactors

Technical catalogue. Modular DIN rail components Installation contactors Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

ZS10 Screw Clamp Terminal Block

ZS10 Screw Clamp Terminal Block Technical Datasheet 1SNK 161 004 D0201 ZS10 Screw Clamp Terminal Block Feed-through Catalogue Page 1SNK 161 004 S0201 10 mm² 6 AWG 8 mm 0.315 in Spacing Features and Benefits 53 2.09" Save space by connecting

More information

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34 LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34 2 LEVEL GAUGES WITH MAGNETIC JOINT SIZE Ø 140/220/340 58 58 TYPE LA TYPE LA 14 30 S 22 33 TYPE LA 22-34 NO. HOLES Ø D2 76 O-RING CENTRE OF THE CONSERVATOR

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02. Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade Technical Datasheet SNK646D00 Catalogue Page SNK646S00 ZS6-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

ZS25 Screw Clamp Terminal Blocks Feed-through

ZS25 Screw Clamp Terminal Blocks Feed-through Technical Datasheet SNK668D0 Catalogue Page SNK678S0 ZS Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to mm² AWG in just mm 0.47 in spacing. SNK68V004 SNK004F0000 D CAD

More information

Pressure controls, type KP

Pressure controls, type KP Introduction KP pressure controls are for use in refrigeration and air conditioning systems to give protection against excessively low suction pressure or excessively high discharge pressure. KP pressure

More information

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm 0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket Technical Datasheet SNK64D00 Catalogue Page SNK64S00 ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket - Ease your test operations with the built-in test sockets, - Screwdriver

More information

Motor circuit-breakers

Motor circuit-breakers Thermal-magnetic motor circuit-breakers type GV2-M GV2-M Thermal-magnetic motor circuit-breakers GV2-M Pushbutton control Standard power ratings Setting Magnetic Thermal Reference Weight of 3-phase motors

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

ELECTROMAGNETIC DISC BRAKES

ELECTROMAGNETIC DISC BRAKES ELECTROMAGNETIC DISC BRAKES TYPE 66E 15/30 52.121 Hand release Lining wear adjustment Torque adjustment 4 holes ø13 DISC SIZE Ø A Braking torque Nm Regulated from (40-100%) Reaction on the shaft N Control

More information

Scraper Passage Indicator. Electrical Indicator. Features

Scraper Passage Indicator. Electrical Indicator. Features IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2 Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened

More information

225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators Actuators Technical data sheet 225-230T-05-S2 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5

More information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,

More information

3 - Cam switches. Contents 0. Complete switches, 10 A. Complete switches, 12 and 20 A. Adaptable sub-assemblies, 12 and 20 A

3 - Cam switches. Contents 0. Complete switches, 10 A. Complete switches, 12 and 20 A. Adaptable sub-assemblies, 12 and 20 A Contents - Cam switches Selection guide............................................. page / Complete switches, A b Front mounting by Ø or Ø mm, with x mm front plate... page / v Switches and stepping switches..............................

More information

400 Series Buccaneer BUCCANEER POWER. bulgin

400 Series Buccaneer BUCCANEER POWER. bulgin bulgin BUCCANEER FOR POWER Contact Retainer Sealing Gasket O Ring Contacts Locking Ring Retaining Nut Panel Body Contacts Contact Carrier O Ring Main Body Cable Gland Collet Gland Nut Sealed to IP68 when

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA w VOLTAGE MONITORING RELAY UR5U1011 w SCHRACK-INFO AC/DC voltage monitoring in 1-phase mains Undervoltage monitoring 1 change over contact Width 17.5 mm Installation design w TECHNICAL DATA 502 1. Functions

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Bimetallic Overload Relay Specifications

Bimetallic Overload Relay Specifications Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

Safety along the complete line: SIRIUS 3SE7 cable-operated switches. sirius COMMANDING & SIGNALING

Safety along the complete line: SIRIUS 3SE7 cable-operated switches. sirius COMMANDING & SIGNALING Safety along the complete line: 3SE7 cable-operated switches sirius COMMANDING & SIGNALING Everything well under control. 3SE7 cable-operated switches With cable-operated switches from our 3SE7 product

More information

Switches & Pilot Devices

Switches & Pilot Devices Key features: 21/4 (8mm) round mounting hole Compact Design Saves Space Bright and Vivid Illumination Choice of Shapes and Functions old Clad Silver Contacts for reliable low level switching Snap action

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

MVX-Series Diesel Engine Air Shut Down Valves

MVX-Series Diesel Engine Air Shut Down Valves MVX-Series Diesel Engine Air Shut Down Valves (Cable operated closure/integral reset lever types) Selection, Application and Maintenance SPECIAL VALVE MVX-304 This is a special version of valve type MVX-303

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators Actuators Technical data sheet 225C-024T-05 Continuous control rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations.

More information

Adjustment functions for both span and shift have been incorporated

Adjustment functions for both span and shift have been incorporated SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8

More information

Operating Instructions Bedienungsanleitung Mode d emploi

Operating Instructions Bedienungsanleitung Mode d emploi Operating Instructions Bedienungsanleitung Mode d emploi DW 400 www.bron-kobold.com Operating instructions DW 400 Before use Please read all the information contained in these operating instructions carefully.

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle

More information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.

More information

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia. Pushbutton Switch (Cylindrical 10.5-dia.) CSM DS_E_4_4 Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment Momentary operation and lock. available in six colors.

More information

SEISMIC VELOCITY TRANSDUCER T1-40

SEISMIC VELOCITY TRANSDUCER T1-40 SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute

More information

OLI. Oil level indicator

OLI. Oil level indicator OLI Oil level indicator Oil level indicator Unexpected or accidental oil leakages may occur randomly along transformer s lifetime. Clear indication of oil level inside transformer tank and on load tap

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for. The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved

More information

Pilot and Signaling Devices. Section 9. www.geindustrial.com Control Catalog 9-1

Pilot and Signaling Devices. Section 9. www.geindustrial.com Control Catalog 9-1 The GE push button offering includes a complete line of control units and stations in both full size (30 mm) push buttons and in smaller size (22 mm) devices which are designed to be used in numerous types

More information