Description of Surge SECTION 3
|
|
|
- Patricia Hawkins
- 9 years ago
- Views:
Transcription
1 SECTION 3 Description of Surge 3-1 SURGE VERSUS STALL Surge is a dynamic instability that occurs in dynamic compressors. Surge can also occur in axial and centrifugal pumps and blowers, but the occurrence is less frequent and the damage less severe. Pump surge seldom occurs except infrequently during cavitation and two-phase flow (Ref. 15). Blower surge does occur but does not damage the blower internals unless the pressure rise exceeds 2 psi and the size exceeds 150 BHP (brake horsepower) (Ref. 22). Surge does not occur in positive displacement compressors and pumps. Stall is another instability that occurs in dynamic compressors and is sometimes confused with surge. The consequences of stall are usually less severe. Pump stall has caused extensive vibration in the piping of boiler feedwater systems (Ref. 15). Stall will be described in enough detail to distinguish it from surge and to understand how it can develop into surge. As the flow through a compressor is reduced, a point is reached where the flow pattern becomes unstable. If the flow oscillates in localized regions around the rotor, the instability is called stall. For axial compressors these regions of unstable forward flow can extend over just a few blades or up to 180 degrees around the annulus in the compressor. In rotating stall, the region of unstable forward flow rotates around the annulus. The average flow across the annulus is still positive. The frequency of the localized flow oscillations ranges from 50 to 21
2 22 Centrifugal and Axial Compressor Control 100 hertz. The stall frequency is some fraction of the compressor speed. The stall frequency does not depend on the design of the piping system in which the compressor is installed. Stall can develop into a more global type of instability called surge. In surge the average flow across the annulus goes through large amplitude oscillations. The frequency of these oscillations ranges from 0.5 to 10 hertz. The surge frequency depends on the designs of both the compressor and piping system. The surge frequency for most industrial compressor installations is slightly less than 1 hertz. Figure 3-1 shows a compressor map for a variable-speed centrifugal compressor. A compressor map is the single most important piece of information for describing surge. A compressor map shows the compressor characteristic curve for different operating conditions. Each curve traces the rise in discharge pressure developed by the compressor as the suction flow is varied for a given operating condition (such as speed). The operating condition is not limited to that shown by the few curves plotted but is continuously adjustable to intermediate values. The X axis is almost always volumetric flow in acfm at the stated suction temperature, pressure, and molecular weight. The Y axis is either the discharge pressure in psia, the ratio of discharge pressure to suction pressure (dimensionless), or the differential pressure rise from suction to discharge in psi. The compressor characteristic curves supplied by the compressor manufacturer cover the negative sloped region and end where the slope approaches zero. (A negative slope means the pressure will change in the opposite direction for a change in flow, and a zero slope means the pressure will not change at all for a change in flow.) If a curve is drawn through the point of zero slope for each characteristic curve, the region to the left of this line is where the instabilities of surge and stall occur. In the literature, this line is called either the stall line or the surge curve. In this text it will be always called the surge curve. The characteristic curve to the left of this curve is difficult to obtain, but its general shape resembles that shown in Figure 3-1. The negative flow portion of the curve can be found by supplying pressurized gas to the compressor discharge to force a steady negative flow. The positive sloped portion of the curve is obtained by smoothly connecting a third-order polynomial curve between the negative sloped negative flow and the positive flow portions of the curve. Surge can be better understood by visualizing a block or throttle valve closing downstream of the compressor. As this valve closes, the suction flow decreases, and the operating point moves to the left along a characteristic curve. If the compressor speed or the guide vane position does not change, the operating point eventually passes by the point of zero slope on the characteristic curve. Just to
3 Description of Surge 23 Figure 3-1 Compressor Map the left of this point, which is the intersection of the surge curve with the characteristic curve, the pressure developed by the compressor is less than the pressure in the piping between the compressor discharge and the closing valve. The forward flow through the compressor stops and reverses direction. The gas flows from the discharge piping back through the compressor to the suction piping. The pressure in the discharge piping starts to drop. When this pressure is below the pressure developed by the compressor, forward flow starts again. If the gas in the discharge piping is still trapped by the closing block or throttle valve, the gas pressure builds up and the surge cycle is repeated. Note that the alternating pressure buildup and decay cycle does not require the flow to actually reverse direction but only to alternately decrease below or increase above the flow rate through the block or throttle valve. Only in severe surges does the flow through the compressor actually reverse direction.
4 24 Centrifugal and Axial Compressor Control Whether a compressor system is stable or unstable depends on how the operating point reacts to a disturbance. If the operating point returns to its initial value after a disturbance, the system is stable. If the deviation of the operating point from its initial value grows or continually oscillates after a disturbance, the system is unstable. A uniform growing deviation is classified as a static instability and an oscillating deviation of growing or constant amplitude is classified as a dynamic instability. Surge is a dynamic instability. Key Concepts Surge and stall occur in dynamic compressors. Stall consists of localized flow oscillations around the rotor. Surge consists of total flow oscillations around the whole rotor. The surge curve is the zero slope points of the characteristic curves. 3-2 STATIC INSTABILITY Static instability is a uniform (non-oscillatory) growing deviation. Static instability will occur when the slope of the compressor characteristic curve is greater than the slope of the demand load curve. As previously mentioned, the demand load curve is a plot of how the pressure drop in the system (due to piping, equipment, and valve resistance) increases with flow. The general criterion is: For static instability, where: S c > S l (3-1) S c = slope of the compressor characteristic curve (psi/acfm) S l = slope of the demand load curve (psi/acfm) Figure 3-2 illustrates how the criterion for static instability can be checked by drawing the demand load curve on a compressor map. The compressor map shows stability at operating point 1 but static instability at operating point 2 where the compressor curve slope is steeper than the load curve slope. Since the compressor curve and the load curve are both steady-state curves, this instability criterion can
5 Description of Surge 25 Figure 3-2 Static Instability Criterion be checked at one steady state or a succession of steady states without knowledge of the system dynamics; hence the name, static instability. An electrical circuit analogy consists of a voltage or current source and a resistance. In this analogy, voltage represents pressure, current represents flow, and electrical resistance represents piping, equipment, and valve resistance. If the compressor characteristic curve is nearly horizontal, which is typical for centrifugal compressors, the circuit has a nonideal voltage source. If the compressor characteristic curve is nearly vertical, which is typical for axial compressors, the circuit has a nonideal current source. This circuit analogy has no dynamic components such as inductors or capacitors so the current flow does not vary with time if the system is stable. The circuit develops static instability if the slope of the source curve is greater than the slope of the resistance curve for voltage versus current. If the slope of the resistance is always positive (voltage drop always increases as current increases) and
6 26 Centrifugal and Axial Compressor Control the slope of the source curve is always negative (voltage rise always decreases as current increases), the circuit is stable. If the slope of the source curve is positive and greater than the slope of the resistance curve, the following sequence of events occurs for any disturbance that causes an increase in voltage output: (1) Increase in source voltage (2) Increase in voltage (driving force) across the resistance (3) Increase in current (4) Increase in source voltage (sequence repeats) The corresponding sequence for a compressor system is: (1) Increase in compressor pressure (2) Increase in pressure (driving force) across the load (3) Increase in flow (4) Increase in compressor pressure (sequence repeats) A similar sequence and exponential growth of any positive deviation occurs in the open-loop response of temperature for runaway exothermic reactors and in the open-loop response of cell concentration for runaway biological reactors (Ref. 21). In a compressor system, static instability occurs when the load curve is nearly flat and intersects the negative sloped portion of the compressor curve. The load curve is nearly flat if a piece of equipment with pressure control such as a reactor, condensor, or absorber is connected to the discharge of a compressor by a short duct or pipe without a throttle valve. Figure 3-2 illustrates this case. The pressure at the starting point of the load curve at zero flow is the static pressure or set point of the pressure control loop for the downstream equipment. The slope of the load curve is proportional to the flow multiplied by twice the resistance of the duct or pipe. Since this duct or pipe is short, its resistance is low, and the slope of the load curve is low at low flow. where: S l = 2 K l Q (3-2) K l = resistance of load (psi/(acfm acfm)) Q = volumetric flow at suction conditions (acfm) S l = slope of the demand load curve (psi/acfm)
7 Description of Surge 27 If the duct or pipe is long, the resistance coefficient K l can still be small if the pipe or duct diameter is large with respect to the flow capacity of an individual compressor. This situation occurs when multiple parallel compressors are supplying a distribution header. The header diameter is selected based on the total flow capacity of all the compressors. The change in pressure drop in the header with a change in flow from an individual compressor is small, and thus the slope of the load curve on the compressor map is small. Static instability occurs only if the compressor system can reach an operating point on the positive sloped portion of the compressor characteristic curve. Normally the flow drops precipitously when the operating point reaches the zero sloped portion of the compressor curve and surge oscillations develop, which is a dynamic instability. Key Concepts Static instability is more likely to occur for parallel compressors. Dynamic instability usually occurs before static instability. 3-3 DYNAMIC INSTABILITY Dynamic instability is characterized by growing oscillations. Dynamic instability can occur if either the discharge plenum volume or the compressor impeller speed is large enough to cause a system response parameter to exceed a minimum value and the slope of the compressor characteristic curve is positive. The general criterion is: For dynamic instability, where: B > B m (3-3) S c > 0 (3-4) B = {N V p /(A c L c )} / (2 a) (3-5) a = speed of sound in the gas (ft/sec) A c = cross-sectional area of flow path in compressor (sq ft)
8 28 Centrifugal and Axial Compressor Control B = system dynamic response parameter (dimensionless) B m = minimum B for dynamic instability (typically 0.1 to 1.0) L c = length of flow path in compressor (ft) N = compressor impeller speed (rev/sec) V p = volume of the plenum (see Figure 3-3) (cu ft) Figure 3-3 shows a simple compressor system with the components identified for the dynamic instability criterion. The plenum is any enclosed volume of gas. In a compressor installation, the plenum may be a vessel or distribution header between the compressor and the block or throttle valve. If the valve is installed directly at the end of a section of pipe or duct connected to the compressor discharge, the volume of this section of pipe or duct can be used as an equivalent plenum volume without seriously degrading the accuracy of Equation 3-3. The compressor flow path length and area are small enough and the plenum volume is large enough in most industrial installations to satisfy the criterion for dynamic instability when the operating point crosses over from the negative to the positive sloped portion of the compressor characteristic curve. However, the oscillation amplitude stops growing due to the nonidealities and nonlinearities of compression in industrial applications. The resulting constant amplitude oscillation Figure 3-3 Simple Compressor System
9 Description of Surge 29 is called a limit cycle. Surge is a dynamic instability that develops into a limit cycle. Stall is not a dynamic instability because the amplitude of the oscillations decreases (decays) with time. Thus the minimum B value (typically 0.1 to 1.0) is the boundary line between surge and stall. Surge occurs when B is above the minimum B, and stall occurs when B is below the minimum B. Also, the severity of surge is proportional to the magnitude of B. Note that this minimum B parameter depends on the compressor speed and the system dimensions and is independent of compressor manufacturer and model number. Thus, different compressors can be compared on a consistent basis. Key Concepts Surge is a dynamic instability (sustained oscillations). The severity of surge increases with speed for a given installation. The severity of surge increases with volume for a given installation. 3-4 CHARACTERISTICS OF SURGE Deep surge starts with a precipitous drop in flow. The flow will typically drop from its set point to its minimum (possibly negative) in less than 0.05 second. No other physical phenomenon can cause such a drop in flow. Figure 3-4 shows the precipitous drop in flow measured by both a slow pneumatic transmitter and a fast electronic d/p flow transmitter. Since this precipitous drop in flow is unique to surge, it can be used as a trigger to actuate an interlock that will open the surge valves or start a surge counter. This drop can be detected by taking the derivative of the d/p signal if the flow measurement signal is not noisy and the transmitter is fast enough (see Section 6-4 for more detail on surge detection methods and Section 7-4 for the effect of transmitter time constant on surge detection). The period of the surge oscillation (time between successive peaks in flow) is shorter than the control loop period unless fast instruments are used and the controller is tuned tight. The surge period is typically less than 2 seconds, while the loop period is usually greater than 4 seconds. Since the surge period is shorter than the loop period, by the time the control loop reacts to a particular portion of the surge cycle, that portion of the surge cycle is long gone. The corrective action by the control loop may become in phase with subsequent surge
10 30 Centrifugal and Axial Compressor Control Figure 3-4 Precipitous Drop in Flow Measured by Two Transmitters (Courtesy Compressor Controls Corporation) cycles and can accentuate the severity of the surge. If the surge period is less than one-fourth the loop period, the surge cycle can be considered as equivalent to uncontrollable noise (Ref. 21). The minimum loop period is approximately equal to 4 times the summation of the instrument time constants and dead times. (See Section 12-1 for more details on how to estimate the loop period for tuning the surge controller.) The minimum surge period that occurs when B is about equal to the minimum B for dynamic stability can be estimated by the following equation: where: T s = {2π (L c V p )/A v }/a (3-6) a = speed of sound (ft/sec) A c = flow path cross-sectional area in compressor (sq ft) L c = flow path length in compressor (ft) T s = surge oscillation period (sec) V p = volume of the plenum (cu ft)
11 Description of Surge 31 Equation 3-6 shows that the surge oscillation period increases as the plenum volume increases. Most industrial compressor installations have a check valve installed on the compressor discharge to prevent backflow during the opening of the surge valves or during the flow reversal caused by surge. This check valve is particularly important for fluidized bed reactor applications to prevent the backflow of catalyst or flammable mixtures. It is also important for parallel compressor applications to prevent pumping gas from one compressor back through another. The check valve will slam shut during the start of surge and will effectively reduce the plenum volume to that of the piping between the compressor and the check valve. Thus, surge oscillation periods are not large even when there is a long header or vessel between the compressor and the block or throttle valve. The plenum pressure does not precipitously drop as does suction flow at the start of surge. Also the oscillation amplitude in pressure is usually less than that in flow during surge. Therefore surge counters or backup control systems that try to detect surge by pressure measurement are liable to experience false or missed surge counts or trips. This is particularly true if pneumatic pressure transmitters are used or if the pressure is noisy or swings with load. The flow oscillation peaks correspond to the filling of the plenum, and the valleys correspond to the emptying of the plenum. The time duration of the peaks and the valleys is typically much longer than the time duration of the transition between the peaks and valleys. The time duration of the peaks and valleys depends on the piping system friction (resistance) and volume (capacitance), while the time duration of the transition depends on the fluid inertia (inductance). The system dynamic response parameter B is proportional to the ratio of the pressure driving force to the inertial impedance. B is representative of the capability to accelerate the gas. As parameter B increases, the amplitude of the oscillations becomes larger and the shape becomes more non-sinusoidal. Figure 3-5a shows the path traced out by the operating point on a compressor map for severe surge where B is about 6 times the minimum B for dynamic stability as a throttle valve is closed downstream of the compressor. Figure 3-5b shows the oscillations in suction flow and discharge pressure that correspond to the path traced out by the operating point in Figure 3-5a. Notice that the oscillation amplitude is extremely large and the shape is non-sinusoidal. In Figure 3-5a, the operating point starts at point A and moves to the left along the compressor characteristic curve as the throttle valve closes. When the operating point reaches point B, which is where the compressor characteristic curve slope is zero, the operating point jumps to point C. This jump corresponds to the precipitous drop in flow that signals the start of the surge cycle. The operating point
12 32 Centrifugal and Axial Compressor Control Figure 3-5a Operating Point Path and Compressor Curve (Severe Surge) cannot follow the positive sloped portion of the compressor curve because the reduced flow out of the plenum, caused by the closing throttle valve, requires that the plenum pressure increase instead of decrease per the curve. (The plenum pressure must increase if the flow into the plenum exceeds the flow out of the plenum.) The flow pattern around the impeller breaks up, and the flow reverses direction to backward flow from the discharge volume to the compressor suction. After this jump to point C, the operating point follows the compressor curve from point C to point D as the plenum volume is emptied due to reverse flow. When the operating point reaches point D, which is where the compressor characteristic slope is zero again, the operating point jumps to point A. The operating point cannot follow the positive sloped portion of the compressor curve because the reduced forward flow into the plenum volume requires that the plenum pressure decrease instead of increase per the curve. (The plenum pressure must decrease if the flow out of the plenum exceeds the flow into the plenum.) The flow pattern around the impeller is established and the flow forward rapidly increases. After the jump to
13 Description of Surge 33 Figure 3-5b Suction Flow and Discharge Pressure Oscillations (Severe Surge) point A, the operating point follows the compressor curve to point B as the plenum volume is filled. The surge cycle repeats itself unless the throttle valve or a surge control valve is opened. The operating point follows the compressor curve only during the peaks and valleys of the surge flow oscillations. The jumps on the compressor map correspond to the rapid transition between the peaks and valleys. The oscillation period is about 1.5 times the period predicted by Equation 3-6. Figure 3-6a shows the path traced out by the operating point on a compressor map for the transition between surge and stall. B has been decreased until it is about equal to the minimum B for dynamic stability by decreasing the speed as a throttle valve is closed downstream of the compressor. Figure 3-6b shows the oscillations in suction flow and discharge pressure that correspond to the path traced out by the operating point in Figure 3-6a. Notice that the oscillation amplitude is an order of magnitude less than that in Figure 3-5b, and the shape is nearly sinusoidal. The B value is actually slightly less than the minimum B because the oscillation amplitude is gradually decreasing, and the path traced out by the
14 34 Centrifugal and Axial Compressor Control Figure 3-6a Operating Point Path and Compressor Curve (Surge to Stall Transition) operating point in Figure 3-6a is gradually spiralling inward. The surge oscillation period is about equal to that predicted by Equation 3-6. Figure 3-7a shows the path traced out by the operating point on a compressor map for stall where B has been decreased to about 0.01 times the minimum B for dynamic stability by decreasing the speed as a throttle valve is closed downstream of the compressor. Figure 3-7b shows the oscillations in suction flow and discharge pressure that correspond to the path traced out by the operating point in Figure 3-7a. Notice that the oscillation amplitude is 2 orders of magnitude less than in Figure 3-6b and decays to zero. The path traced out by the operating point in Figure 3-7a rapidly spirals inward and converges to the point of zero flow. The operating point approaches zero flow because the throttle valve downstream closed completely, which stopped flow out of the system except for a small leakage flow. If the throttle valve had remained slightly open, the spiral would have converged to a point of positive flow on the positive sloped portion of the compressor curve. The stall oscillation period is about 1/2 the period predicted by
15 Description of Surge 35 Figure 3-6b Suction Flow and Discharge Pressure Oscillations (Surge to Stall Transition) Equation 3-6. This characteristic of compressor response, where the oscillation period decreases as the amplitude decreases, is the opposite of the characteristic of general control system response. The ultimate period of a control system occurs at the transition from stable to unstable operation (similar to the transition from stall to surge). However, for unstable operation (growing oscillations) the control loop period decreases, and for stable operation (decaying oscillations) the loop period increases. The plots in Figures 3-5 and 3-6 were generated by an advanced continuous simulation language (ACSL) program documented in Appendix B. The program is based on the Greitzer model of surge that was described and experimentally tested by K.E. Hansen et al. (Ref. 16). The ACSL program integrates the differential equations for the momentum and mass balances and computes the stability parameter B, the surge period, and the system flows and pressures. The user must enter data on compressor curve shape, compressor speed, system geometry, surge valve, and throttle valve.
16 36 Centrifugal and Axial Compressor Control Figure 3-7a Operating Point Path and Compressor Curve (Stall) Key Concepts Deep surge starts with a precipitous drop in total flow. The surge period is much shorter than the control loop period. The surge period increases with volume for a given installation. The surge period increases slightly with surge severity. The surge shape becomes more non-sinusoidal with surge severity. 3-5 CONSEQUENCES OF SURGE The rapid flow reversals cause extensive radial vibration and axial thrust displacement. The reheating of the same mass of gas during each surge cycle causes a large temperature increase. The gas temperature rise is particularly dramatic for axial compressors, with an observed increase in temperature of 3000 F after 10 surge
17 Description of Surge 37 Figure 3-7b Suction Flow and Discharge Pressure Oscillations (Stall) cycles for one installation (Ref. 26). Vibration and thrust monitors have built-in electronic delays to prevent false alarms or trips due to noise. Temperature sensors have thermal lags due to the resistance to heat transfer of the sensor and thermowell construction (see Section 7). As a result these instruments will usually actuate an alarm or shutdown after several surge cycles have occurred. In the interim, the increase in vibration, thrust, and temperature can cause extensive damage to the compressor. The repair costs can range from thousands to millions of dollars. If the compressor is the sole supplier of gas for a plant unit, the business interruption loss can be much greater than the repair costs, particularly if a replacement rotor must be manufactured, the plant product was sold out at the time of the interruption, or customers switch permanently to a competitor. Even if the damage is not noticeable, the surge can change the internal clearances enough to decrease the efficiency of the compressor. Up to a 0.5 percent loss in efficiency may result from a few cycles of surge (Ref. 26). Repeated surges will cause a significant accumulated loss in efficiency.
18 38 Centrifugal and Axial Compressor Control The rapid unloading of the impeller during flow breakdown can cause overspeed of the compressor. Field measurements (with an oscillographic recorder) of the speed of one compressor during the start of surge indicated that the compressor acceleration increased to 2000 rpm per sec until power was removed. This increase in the derivative of the speed (acceleration) is characteristic of a runaway or positive feedback open-loop response (Ref. 21). The runaway response was so rapid that the speed controller for the tested compressor could not react and prevent overspeed damage at the start of surge. Consequently, the only alternative was to shut down the compressor when the output of a derivative module indicated the start of a runaway speed response (700 rpm per second). The same module started the oscillographic recorder at 300 rpm per second acceleration to capture a record of the operating conditions just prior to the shutdown. The power was removed from the compressor by closing the steam turbine and expander supply valves in less than one half second. The flow reversals during surge can produce a booming noise loud enough to make surge a memorable experience for personnel in the vicinity of the compressor. The booming noise can originate from collapsing gas voids within the compressor, the flexing of the suction filter walls, or the slamming shut of the check valve. Key Concepts High vibration, thrust, temperature, and speed can occur during surge. Many instruments are too slow to detect surge quickly enough. Internal damage and loss in efficiency can result from surge.
Centrifugal Fans and Pumps are sized to meet the maximum
Fans and Pumps are sized to meet the maximum flow rate required by the system. System conditions frequently require reducing the flow rate. Throttling and bypass devices dampers and valves are installed
TOPIC: 191004 KNOWLEDGE: K1.01 [3.3/3.5] Which one of the following contains indications of cavitation in an operating centrifugal pump?
KNOWLEDGE: K1.01 [3.3/3.5] P21 Which one of the following contains indications of cavitation in an operating centrifugal pump? A. Low flow rate with low discharge pressure. B. Low flow rate with high discharge
C. starting positive displacement pumps with the discharge valve closed.
KNOWLEDGE: K1.04 [3.4/3.6] P78 The possibility of water hammer in a liquid system is minimized by... A. maintaining temperature above the saturation temperature. B. starting centrifugal pumps with the
Example. Fluid Power. Circuits
Example Fluid Power Circuits To Enhance Symbol Reading Skills To Work On Circuit Reading Skills With Answers HI LO Pump Circuit 18 A1 B1 17 16 15 13 Set 14 2,000 PSI PG2 Set 500 PSI 12 11 7 8 10 PG1 9
CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.
CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc. 1 Centrifugal Pump- Definition Centrifugal Pump can be defined as a mechanical device used to transfer liquid of various types. As
Hydrate Occurrence in Centrifugal Compressor Systems
Hydrate Occurrence in Centrifugal Compressor Systems Orlando Donda Filho, Senior Engineer, Petrobras Eder Ramalho, Fleet Manager, Caterpillar Solar Turbines, Macaé Pedro Antonio Lima Donda, Senior Maintenance
Module 9: Basics of Pumps and Hydraulics Instructor Guide
Module 9: Basics of Pumps and Hydraulics Instructor Guide Activities for Unit 1 Basic Hydraulics Activity 1.1: Convert 45 psi to feet of head. 45 psis x 1 ft. = 103.8 ft 0.433 psi Activity 1.2: Determine
Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001
Pressure Control Chapter 3 Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001 Introduction Pressure control is a key element in the design of any circuit. Used correctly, it can
CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES
CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES 4.0 PUMP CLASSES Pumps may be classified in two general types, dynamic and positive displacement. Positive displacement pumps
Entrained Gas Diagnostic with Intelligent Differential Pressure Transmitter
January Page Entrained Gas Diagnostic with Intelligent Differential Pressure Transmitter Dave Wehrs - Director, Pressure Engineering Andrew Klosinski - Application Engineer, Pressure Diagnostics Emerson
Theory, Application, and Sizing of Air Valves
Theory, Application, and Sizing of Air Valves VAL-MATIC VALVE AND MANUFACTURING CORP. 905 RIVERSIDE DRIVE, ELMHURST, IL 60126 TEL. (630) 941-7600 FAX. (630) 941-8042 www.valmatic.com 1 THEORY, APPLICATION,
HITACHI INVERTER SJ/L100/300 SERIES PID CONTROL USERS GUIDE
HITACHI INVERTER SJ/L1/3 SERIES PID CONTROL USERS GUIDE After reading this manual, keep it for future reference Hitachi America, Ltd. HAL1PID CONTENTS 1. OVERVIEW 3 2. PID CONTROL ON SJ1/L1 INVERTERS 3
Minor losses include head losses through/past hydrants, couplers, valves,
Lecture 10 Minor Losses & Pressure Requirements I. Minor Losses Minor (or fitting, or local ) hydraulic losses along pipes can often be estimated as a function of the velocity head of the water within
Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.
ASGMT / Averaging Pitot Tube Flow Measurement Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc. Averaging Pitot Tube Meters Introduction
OPERATING FANS IN PARALLEL IN VIEW OF VARIABLE FLOW RATE OUTPUT
OPERATING FANS IN PARALLEL IN VIEW OF VARIABLE FLOW RATE OUTPUT Eddy J. Jacques & Pierre J. Wauters Department of Mechanical Engineering, Unité TERM, Université Catholique de Louvain, Belgium ABSTRACT
FAN PROTECTION AGAINST STALLING PHENOMENON
FAN PROTECTION AGAINST STALLING PHENOMENON Roberto Arias Álvarez 1 Javier Fernández López 2 2 1 ZITRON Technical Director [email protected] ZITRON Technical Pre Sales Management [email protected]
Positive Feedback and Oscillators
Physics 3330 Experiment #6 Fall 1999 Positive Feedback and Oscillators Purpose In this experiment we will study how spontaneous oscillations may be caused by positive feedback. You will construct an active
Chapter 3.5: Fans and Blowers
Part I: Objective type questions and answers Chapter 3.5: Fans and Blowers 1. The parameter used by ASME to define fans, blowers and compressors is a) Fan ration b) Specific ratio c) Blade ratio d) Twist
FREQUENCY CONTROLLED AC MOTOR DRIVE
FREQUENCY CONTROLLED AC MOTOR DRIVE 1.0 Features of Standard AC Motors The squirrel cage induction motor is the electrical motor motor type most widely used in industry. This leading position results mainly
Unsteady Pressure Measurements
Quite often the measurements of pressures has to be conducted in unsteady conditions. Typical cases are those of -the measurement of time-varying pressure (with periodic oscillations or step changes) -the
ADVANCED CONTROL TECHNIQUE OF CENTRIFUGAL COMPRESSOR FOR COMPLEX GAS COMPRESSION PROCESSES
ADVANCED CONTROL TECHNIQUE OF CENTRIFUGAL COMPRESSOR FOR COMPLEX GAS COMPRESSION PROCESSES by Kazuhiro Takeda Research Manager, Research and Development Center and Kengo Hirano Instrument and Control Engineer,
Manufacturing Equipment Modeling
QUESTION 1 For a linear axis actuated by an electric motor complete the following: a. Derive a differential equation for the linear axis velocity assuming viscous friction acts on the DC motor shaft, leadscrew,
Application Information
Moog Components Group manufactures a comprehensive line of brush-type and brushless motors, as well as brushless controllers. The purpose of this document is to provide a guide for the selection and application
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 3 HYDRAULIC AND PNEUMATIC MOTORS The material needed for outcome 2 is very extensive
NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES
NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES 8.1 INTRODUCTION Testing, adjusting, and balancing of HVAC systems can best be accomplished by following a series of systematic procedures. The NEBB TAB
ENERGY TRANSFER SYSTEMS AND THEIR DYNAMIC ANALYSIS
ENERGY TRANSFER SYSTEMS AND THEIR DYNAMIC ANALYSIS Many mechanical energy systems are devoted to transfer of energy between two points: the source or prime mover (input) and the load (output). For chemical
PUMPS TYPE OF PUMP PRESSURE/FLOW RATING CHARACTERISTICS. Centrifugal Low Pressure/High Flow Flow changes when
PUMPS Pumps provide the means for moving water through the system at usable working pressures. The operation and maintenance of these pumps are some of the most important duties for many water utility
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business
Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic energy).
HYDRAULIC MACHINES Used to convert between hydraulic and mechanical energies. Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic
Chapter 10. Control Design: Intuition or Analysis?
Chapter 10 Control Design: Intuition or Analysis? Dan P. Dumdie 10.1 Introduction In previous chapters, we discussed some of the many different types of control methods available and typically used in
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 1 HYDRAULIC PUMPS The material needed for outcome 2 is very extensive so there
BASIC ELECTRONICS AC CIRCUIT ANALYSIS. December 2011
AM 5-202 BASIC ELECTRONICS AC CIRCUIT ANALYSIS December 2011 DISTRIBUTION RESTRICTION: Approved for Pubic Release. Distribution is unlimited. DEPARTMENT OF THE ARMY MILITARY AUXILIARY RADIO SYSTEM FORT
SYNCHRONOUS MACHINES
SYNCHRONOUS MACHINES The geometry of a synchronous machine is quite similar to that of the induction machine. The stator core and windings of a three-phase synchronous machine are practically identical
Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson
Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology HWEA 2011 Conference Craig S. Johnson Presentation Overview Introduction Aeration Air & Digester gas challenges Gas flow metering
Chapter 8: Flow in Pipes
Objectives 1. Have a deeper understanding of laminar and turbulent flow in pipes and the analysis of fully developed flow 2. Calculate the major and minor losses associated with pipe flow in piping networks
THE USE OF A CORIOLIS FLOW METER FOR MEASURING MOLASSES PRODUCTION IN A SUGAR MILL. ABSTRACT
THE USE OF A CORIOLIS FLOW METER FOR MEASURING MOLASSES PRODUCTION IN A SUGAR MILL. P. W. Rein 1, D. J. Muzzell 2, and N. Dolan 2 1 Audubon Sugar Institute, LSU AgCenter, St. Gabriel, LA, 2 Raceland Raw
Understanding Power Impedance Supply for Optimum Decoupling
Introduction Noise in power supplies is not only caused by the power supply itself, but also the load s interaction with the power supply (i.e. dynamic loads, switching, etc.). To lower load induced noise,
Turbo Tech 101 ( Basic )
Turbo Tech 101 ( Basic ) How a Turbo System Works Engine power is proportional to the amount of air and fuel that can get into the cylinders. All things being equal, larger engines flow more air and as
Power Supplies. 1.0 Power Supply Basics. www.learnabout-electronics.org. Module
Module 1 www.learnabout-electronics.org Power Supplies 1.0 Power Supply Basics What you ll learn in Module 1 Section 1.0 Power Supply Basics. Basic functions of a power supply. Safety aspects of working
Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials.
Lab 3 Tension Test Objectives Concepts Background Experimental Procedure Report Requirements Discussion Objectives Experimentally determine the yield strength, tensile strength, and modules of elasticity
A BRIEF INTRODUCTION TO CENTRIFUGAL PUMPS
A BRIEF INTRODUCTION TO CENTRIFUGAL PUMPS figure below is a cross section of a centrifugal pump and shows the two basic parts. Joe Evans, Ph.D IMPELLER This publication is based upon an introductory, half
Air Conditioning Clinic
Air Conditioning Clinic Air Conditioning Fans One of the Equipment Series February 2012 TRG-TRC013-EN Air Conditioning Fans One of the Equipment Series A publication of Trane Preface Air Conditioning
Dynamic Process Modeling. Process Dynamics and Control
Dynamic Process Modeling Process Dynamics and Control 1 Description of process dynamics Classes of models What do we need for control? Modeling for control Mechanical Systems Modeling Electrical circuits
Experiment 3 Pipe Friction
EML 316L Experiment 3 Pipe Friction Laboratory Manual Mechanical and Materials Engineering Department College of Engineering FLORIDA INTERNATIONAL UNIVERSITY Nomenclature Symbol Description Unit A cross-sectional
Pump Maintenance - Repair
Pump Maintenance - Repair Brian Trombly Mo Droppers Cummins Bridgeway, Gaylord, Mi The basic centrifugal pump consists of two main elements: 1. The rotating element which includes an impeller and a shaft.
Practice Problems on Boundary Layers. Answer(s): D = 107 N D = 152 N. C. Wassgren, Purdue University Page 1 of 17 Last Updated: 2010 Nov 22
BL_01 A thin flat plate 55 by 110 cm is immersed in a 6 m/s stream of SAE 10 oil at 20 C. Compute the total skin friction drag if the stream is parallel to (a) the long side and (b) the short side. D =
Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations
Stephen Lowe ASHRAE Hampton Roads Chapter Past President AECOM Design Mechanical Engineering Discipline Manager, Virginia Beach Division Professional Engineer Commonwealth of Virginia, NCEES BSME University
Lambda Tuning the Universal Method for PID Controllers in Process Control
Lambda Tuning the Universal Method for PID Controllers in Process Control Lambda tuning gives non-oscillatory response with the response time (Lambda) required by the plant. Seven industrial examples show
Pressure drop in pipes...
Pressure drop in pipes... PRESSURE DROP CALCULATIONS Pressure drop or head loss, occurs in all piping systems because of elevation changes, turbulence caused by abrupt changes in direction, and friction
Section IV VACUUM PUMPS. Vacuum Pumps: Basic Operation
VACUUM PUMPS Section IV Equipment used to generate vacuum, as noted earlier, is similar to air compressors. It's even possible to generate compressed air or vacuum with the same machine, depending on how
Chapter 11 SERVO VALVES. Fluid Power Circuits and Controls, John S.Cundiff, 2001
Chapter 11 SERVO VALVES Fluid Power Circuits and Controls, John S.Cundiff, 2001 Servo valves were developed to facilitate the adjustment of fluid flow based on the changes in the load motion. 1 Typical
Basic Op Amp Circuits
Basic Op Amp ircuits Manuel Toledo INEL 5205 Instrumentation August 3, 2008 Introduction The operational amplifier (op amp or OA for short) is perhaps the most important building block for the design of
Introduction. Chapter 1. 1.1 The Motivation
Chapter 1 Introduction 1.1 The Motivation Hydroelectric power plants, like real systems, have nonlinear behaviour. In order to design turbine controllers, it was normal practice in the past, when computer
Line Reactors and AC Drives
Line Reactors and AC Drives Rockwell Automation Mequon Wisconsin Quite often, line and load reactors are installed on AC drives without a solid understanding of why or what the positive and negative consequences
export compressor instability detection using system 1* and proficy** smartsignal software
BP MAGNUS PLATFORM export compressor instability detection using system 1* and proficy** smartsignal software part 1 58 ORBIT Vol.32 No.3 Jul.2012 THIS CASE STUDY DESCRIBES AN EXAMPLE OF A GAS COMPRESSOR
Input and Output Capacitor Selection
Application Report SLTA055 FEBRUARY 2006 Input and Output Capacitor Selection Jason Arrigo... PMP Plug-In Power ABSTRACT When designing with switching regulators, application requirements determine how
Understanding Ignition Waveforms
FIRE IN THE HOLE Understanding Ignition Waveforms BY BERNIE C. THOMPSON The ignition waveform is a window that allows you to see what s occurring in the combustion chamber. Join us for a closer look. From
Process Control Primer
Process Control Primer At the onset of the Industrial Revolution, processes were controlled manually. Men turned valves, pulled levers or changed switches based on the need to turn devices on or off. As
SELECTING PRESSURE TRANSMITTERS TO IMPROVE CENTRIFUGAL COMPRESSOR SAFETY & EFFICIENCY
SELECTING PRESSURE TRANSMITTERS TO IMPROVE CENTRIFUGAL COMPRESSOR SAFETY & EFFICIENCY Mark Menezes Manager Pressure & PlantWeb (Americas) Rosemount Inc. Chanhassen, MN 55317 KEYWORDS Centrifugal compressor,
Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA
Speed Control Methods of Various Types of Speed Control Motors Kazuya SHIRAHATA Oriental Motor Co., Ltd. offers a wide variety of speed control motors. Our speed control motor packages include the motor,
Introduction to the Smith Chart for the MSA Sam Wetterlin 10/12/09 Z +
Introduction to the Smith Chart for the MSA Sam Wetterlin 10/12/09 Quick Review of Reflection Coefficient The Smith chart is a method of graphing reflection coefficients and impedance, and is often useful
Transmission Line and Back Loaded Horn Physics
Introduction By Martin J. King, 3/29/3 Copyright 23 by Martin J. King. All Rights Reserved. In order to differentiate between a transmission line and a back loaded horn, it is really important to understand
Reading assignment: All students should read the Appendix about using oscilloscopes.
10. A ircuits* Objective: To learn how to analyze current and voltage relationships in alternating current (a.c.) circuits. You will use the method of phasors, or the vector addition of rotating vectors
Pressurized Water Reactor B&W Technology Crosstraining Course Manual. Chapter 9.0. Integrated Control System
Pressurized Water Reactor B&W Technology Crosstraining Course Manual Chapter 9.0 Integrated Control System TABLE OF CONTENTS 9.0 INTEGRATED CONTROL SYSTEM... 1 9.1 Introduction... 1 9.2 General Description...
Inrush Current. Although the concepts stated are universal, this application note was written specifically for Interpoint products.
INTERPOINT Although the concepts stated are universal, this application note was written specifically for Interpoint products. In today s applications, high surge currents coming from the dc bus are a
A simple method to determine control valve performance and its impacts on control loop performance
A simple method to determine control valve performance and its impacts on control loop performance Keywords Michel Ruel p.eng., Top Control Inc. Process optimization, tuning, stiction, hysteresis, backlash,
Water hammering in fire fighting installation
Water hammering in fire fighting installation Forward One of major problems raised in the fire fighting network installed at Pioneer company for pharmaceutical industry /Sulaymania was the high water hammering
an EnPro Industries company
QGV an EnPro Industries company QUINCY QGV SERIES ROTARY SCREW AIR COMPRESSORS 50 200 HP QUINCY QGV 50-200 Model QGV-50 QGV-75 QGV-100 QGV-150 QGV-200 Motor (hp) 50 75 100 150 200 Air Delivery (acfm) 100
Agricultural Pumping Efficiency Improvements
APPLICATION NOTE An In-Depth Examination of an Energy Efficiency Technology Agricultural Pumping Efficiency Improvements Summary...1 How This Technology Saves Energy...2 Types of Energy Efficiency Measures...4
Technical Guide No. 100. High Performance Drives -- speed and torque regulation
Technical Guide No. 100 High Performance Drives -- speed and torque regulation Process Regulator Speed Regulator Torque Regulator Process Technical Guide: The illustrations, charts and examples given in
KINETIC ENERGY RECOVERY SYSTEM BY MEANS OF FLYWHEEL ENERGY STORAGE
ADVANCED ENGINEERING 3(2009)1, ISSN 1846-5900 KINETIC ENERGY RECOVERY SYSTEM BY MEANS OF FLYWHEEL ENERGY STORAGE Cibulka, J. Abstract: This paper deals with the design of Kinetic Energy Recovery Systems
Drive circuit basics + V. τ e. Industrial Circuits Application Note. Winding resistance and inductance
ndustrial Circuits Application Note Drive circuit basics For a given size of a stepper motor, a limited space is available for the windings. n the process of optimizing a stepper motor drive system, an
Characteristics of Centrifugal Blower and Its Effective Use in High Static Pressure Area
Characteristics of Centrifugal Blower and Its Effective Use in High Static Pressure Area Masayuki TAKAHASHI With small fans, selecting the right fan that most fits the purpose is extremely important from
Troubleshooting accelerometer installations
Troubleshooting accelerometer installations Accelerometer based monitoring systems can be tested to verify proper installation and operation. Testing ensures data integrity and can identify most problems.
SAMPLE CHAPTERS UNESCO EOLSS
STEAM TURBINE OPERATIONAL ASPECTS R.A. Chaplin Department of Chemical Engineering, University of New Brunswick, Canada Keywords: Steam Turbines, Operation, Supersaturation, Moisture, Back Pressure, Governing
Physics 9e/Cutnell. correlated to the. College Board AP Physics 1 Course Objectives
Physics 9e/Cutnell correlated to the College Board AP Physics 1 Course Objectives Big Idea 1: Objects and systems have properties such as mass and charge. Systems may have internal structure. Enduring
Measurement Types in Machinery Monitoring
February 2014 Measurement Types in Machinery Monitoring Online machinery monitoring for rotating equipment is typically divided into two categories: 1. Protection Monitoring 2. Prediction Monitoring This
Fire Pump Plan Review March 2010
Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:
LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS
LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS 1. Define an accumulator and explain its function A hydraulic accumulator is a device that stores the potential energy of an incompressible fluid
PEERLESS PUMP COMPANY SYSTEM ANALYSIS FOR PUMPING EQUIPMENT SELECTION
PEERLESS PUMP COMPANY SYSTEM ANALYSIS FOR PUMPING EQUIPMENT SELECTION Peerless Pump Company 005 Dr. Martin Luther King Jr. Street P.O. Box 706 Indianapolis, Indiana 4607-706 Phone: (317) 95-9661 Fax: (317)
Active Vibration Isolation of an Unbalanced Machine Spindle
UCRL-CONF-206108 Active Vibration Isolation of an Unbalanced Machine Spindle D. J. Hopkins, P. Geraghty August 18, 2004 American Society of Precision Engineering Annual Conference Orlando, FL, United States
Industrial Steam System Process Control Schemes
Industrial Steam System Process Control Schemes This paper was developed to provide a basic understanding of the different process control schemes used in a typical steam system. This is however a fundamental
ENERGY SAVING OF OIL HYDRAULIC PUMP UNIT BY IDLING STOP METHOD USING AN ACCUMULATOR
ENERGY SAVING OF OIL HYDRAULIC PUMP UNIT BY IDLING STOP METHOD USING AN ACCUMULATOR Katsumasa Suzuki 1, Yoshitaka Niimura 1, Kazutoshi Akitani 1 and Ken Sugimura 2 ABSTRACT In recent years, energy saving
The Piping System Model a New Life Cycle Document. Elements of the Piping System Model
Piping System Model as a Life Cycle Document White Paper Introduction When designing piping systems, a variety of documents are created providing the details necessary to design, purchase, build, and test
Operational Amplifier as mono stable multi vibrator
Page 1 of 5 Operational Amplifier as mono stable multi vibrator Aim :- To construct a monostable multivibrator using operational amplifier 741 and to determine the duration of the output pulse generated
Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1
Fault codes DM1 Industrial engines DC09, DC13, DC16 Marine engines DI09, DI13, DI16 03:10 Issue 5.0 en-gb 1 DM1...3 Abbreviations...3 Fault type identifier...3...4 03:10 Issue 5.0 en-gb 2 DM1 DM1 Fault
Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.
COOLING FAN REQUIREMENTS CALCULATIONS Determining System Impedance Determining the actual airflow produced by a fan mounted in an enclosure is much more difficult than calculating the airflow required.
Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim
Automotive sensor simulator Operating manual AutoSim Contents Introduction.. page 3 Technical specifications.... page 4 Typical application of AutoSim simulator..... page 4 Device appearance... page 5
BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.
SUBMERSIBLE PUMP selection A submersible pump consists of the following basic elements: < Bowl Assembly < Motor < Cable < Drop Pipe < Surface Plate (with)(without) discharge elbow DATA REQUIRED FOR SELECTION
Procon Engineering. Technical Document PELR 1002. TERMS and DEFINITIONS
Procon Engineering Technical Document PELR 1002 TERMS and DEFINITIONS The following terms are widely used in the weighing industry. Informal comment on terms is in italics and is not part of the formal
Operations & Maintenance 201 Using online monitoring and predictive diagnostics to reduce maintenance costs
2003 Emerson Process Management. All rights reserved. View this and other courses online at www.plantwebuniversity.com. Operations & Maintenance 201 Using online monitoring and predictive diagnostics to
8 Speed control of Induction Machines
8 Speed control of Induction Machines We have seen the speed torque characteristic of the machine. In the stable region of operation in the motoring mode, the curve is rather steep and goes from zero torque
Part IV. Conclusions
Part IV Conclusions 189 Chapter 9 Conclusions and Future Work CFD studies of premixed laminar and turbulent combustion dynamics have been conducted. These studies were aimed at explaining physical phenomena
DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING
By Philip Sutter Pick Heaters, Inc. DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING INTRODUCTION Many process plants currently use steam or hot water to heat jacketed devices such as tanks,
Why and How we Use Capacity Control
Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,
Product Data Bulletin
Product Data Bulletin Adjustable Frequency Drives and HVAC Systems An Application Guide September, 1994 Raleigh, NC, U.S.A. INTRODUCTION All buildings pose the same problem: how to heat or cool the air
Chapter 3 AUTOMATIC VOLTAGE CONTROL
Chapter 3 AUTOMATIC VOLTAGE CONTROL . INTRODUCTION TO EXCITATION SYSTEM The basic function of an excitation system is to provide necessary direct current to the field winding of the synchronous generator.
Applications of Second-Order Differential Equations
Applications of Second-Order Differential Equations Second-order linear differential equations have a variety of applications in science and engineering. In this section we explore two of them: the vibration
Hybrid Modeling and Control of a Power Plant using State Flow Technique with Application
Hybrid Modeling and Control of a Power Plant using State Flow Technique with Application Marwa M. Abdulmoneim 1, Magdy A. S. Aboelela 2, Hassen T. Dorrah 3 1 Master Degree Student, Cairo University, Faculty