1 Power Quality Reactive Energy Management Low Voltage components Catalogue 2014
2 Power Quality Your requirements. Optimize energy consumption By reducing electricity bills, By reducing power losses, By reducing CO 2 emissions. Increase power availability Compensate for voltage sags detrimental to process operation, Avoid nuisance tripping and supply interruptions. Improve your business performance Optimize installation size, Reduce harmonic distortion to avoid the premature ageing of equipment and destruction of sensitive components.
3 Our solutions. Reactive energy management In electrical networks, reactive energy results in increased line currents for a given active energy transmitted to loads. The main consequences are: Need for oversizing of transmission and distribution networks by utilities, Increased voltage drops and sags along the distribution lines, Additional power losses. This results in increased electricity bills for industrial customers because of: Penalties applied by most utilities on reactive energy, Increased overall kva demand, Increased energy consumption within the installations. Reactive energy management aims to optimize your electrical installation by reducing energy consumption, and to improve power availability. Total CO 2 emissions are also reduced. Utility power bills are typically reduced by 5 % to 10 %. + Our energy con-sumption was reduced by 9 % after we installed 10 capacitor banks with detuned reactors. Electricity bill optimised by 8 % and payback in 2 years. Testifies Michelin Automotive in France. Energy consumption reduced by 5 % with LV capacitor bank and active filter installed. POMA OTIS Railways, Switzerland. 70 capacitor banks with detuned reactors installed, energy consumption reduced by 10 %, electrcity bill optimised by 18 %, payback in just 1 year. Madrid Barrajas airport Spain. Our network performance improved significantly after we installed 225 LV Detuned capacitor banks. The capacitor banks incorporates advanced metering system and remote communication ensures continued operation and minimal down time. Ministry of Electricity and Water, Kuwait. III
4 Improve electrical networks and reduce energy costs Power Factor Correction Every electric machine needs active power (kw) and reactive power (kvar) to operate. The power rating of the installation in kva is the combination of both: (kva)² = (kw)² + (kvar)². The Power Factor has been defined as the ratio of active power (kw) to apparent power (kva). Power Factor = (kw) / (kva). The objective of Reactive Energy management is improvement of Power Factor, or Power Factor Correction. This is typically achieved by producing reactive energy close to the consuming loads, through connection of capacitor banks to the network. IV
5 Ensure reliability and safety on installations Quality and reliability Continuity of service thanks to the high performance and long life expectancy of capacitors. 100% testing in manufacturing plant. Design and engineering with the highest international standards. Safety Tested safety features integrated on each phase. Over-pressure system for safe disconnection at the end of life. All materials and components are free of PCB pollutants. + Thanks to the know-how developed over 50 years, Schneider Electric ranks as the global specialist in Energy management providing a unique and comprehensive portfolio. Schneider Electric helps you to make the most of your energy with innovative, reliable and safe solutions. Efficiency and productivity Product development including innovation in ergonomics and ease of installation and connection. Specially designed components to save time on installation and maintenance. All components and solutions available through a network of distributors and partners in more than 100 countries. V
6 Quality & Environment Quality certified - ISO9001, ISO14001 and ISO50001 A major strength In each of its units, Schneider Electric has an operating organization whose main role is to verify quality and ensure compliance with standards. This procedure is: uniform for all departments; recognized by numerous customers and official organizations. But, above all, its strict application has made it possible to obtain the recognition of independent organizations. The quality system for design and manufacturing is certified in compliance with the requirements of the ISO 9001 and ISO Quality Assurance model. Stringent, systematic controls During its manufacture, each equipment item undergoes systematic routine tests to verify its quality and compliance: measurement of operating capacity and tolerances; measurement of losses; dielectric testing; checks on safety and locking systems; checks on low-voltage components; verification of compliance with drawings and diagrams. The results obtained are recorded and initialled by the Quality Control Department on the specific test certificate for each device. Schneider Electric undertakes to reduce the energy bill and CO 2 emissions of its customers by proposing products, solutions and services which fit in with all levels of the energy value chain. The Power Factor Correction and harmonic filtering offer form part of the energy efficiency approach. RoHS, REACh Compliance All LV PFC Components of Schneider Electric are RoHS, REACh Compliant. VI
7 A new solution for building your electrical installations A comprehensive offer Power Factor Correction and harmonic filtering form part of a comprehensive offer of products perfectly coordinated to meet all medium- and low-voltage power distribution needs. Use of these products in the electrical installation will result in: improved continuity of service; reduced power losses; guarantee of scalability; efficient monitoring and management. You thus have all the trumps in hand in terms of expertise and creativity for optimized, reliable, expandable and compliant installations. Tools for easier design and setup With Schneider Electric, you have a complete range of tools that support you in the knowledge and setup of products, all this in compliance with the standards in force and standard engineering practice. These tools, technical notebooks and guides, design aid software, training courses, etc. are regularly updated. Schneider Electric joins forces with your expertise and your creativity for optimized, reliable, expandable and compliant installations. Because each electrical installation is a specific case, there is no universal solution. The variety of combinations available allows you to achieve genuine customization of technical solutions. You can express your creativity and highlight your expertise in the design, development and operation of an electrical installation. VII
8
9 Power Quality General contents Power Factor Correction guideline 3 Low Voltage capacitors 15 Detuned reactors 51 Power Factor controllers 57 Contactors 61 Appendix 65 1
10 2
11 Power Factor Correction guideline Contents Presentation Why reactive energy management? 4 Method for determining compensation 6 Low Voltage capacitors with detuned reactors 10 Rated voltage and current 11 Capacitor selection guide 12 Construction of references Principle 13 Low Voltage capacitors 15 Detuned reactors 51 Power Factor controllers 57 Contactors 61 Appendix 65 3
12 Power Factor Correction guideline Why reactive energy management? Principle of reactive energy management + Due to this higher supplied current, the circulation of reactive energy in distribution networks results in: > Overload of transformers > Higher temperature rise in power cables > Additional losses > Large voltage drops > Higher energy consumption and cost > Less distributed active power. DE90087.eps In this representation, the Power Factor (P/S) is equal to cosj. DE90071_r.eps All AC electrical networks consume two types of power: active power (kw) and reactive power (kvar): The active power P (in kw) is the real power transmitted to loads such as motors, lamps, heaters, computers, etc. The electrical active power is transformed into mechanical power, heat or light. The reactive power Q (in kvar) is used only to power the magnetic circuits of machines, motors and transformers. The apparent power S (in kva) is the vector combination of active and reactive power. The circulation of reactive power in the electrical network has major technical and economic consequences. For the same active power P, a higher reactive power means a higher apparent power, and thus a higher current must be supplied. The circulation of active power over time results in active energy (in kwh). The circulation of reactive power over time results in reactive energy (kvarh). In an electrical circuit, the reactive energy is supplied in addition to the active energy. Power generation Active energy Reactive energy Transmission network Reactive energy supplied and billed by the energy provider. Active energy Reactive energy Motor DE90088.eps Q Q c For these reasons, there is a great advantage in generating reactive energy at the load level in order to prevent the unnecessary circulation of current in the network. This is what is known as power factor correction. This is obtained by the connection of capacitors, which produce reactive energy in opposition to the energy absorbed by loads such as motors. The result is a reduced apparent power, and an improved power factor P/S as illustrated in the diagram opposite. The power generation and transmission networks are partially relieved, reducing power losses and making additional transmission capacity available. DE90071_r.eps Power generation Active energy Transmission network Active energy Reactive energy Motor The reactive power is supplied by capacitors. No billing of reactive power by the energy supplier. Capacitors 4
13 Why reactive energy management? + Benefits of reactive energy management Optimized management of reactive energy brings economic and technical advantages. Savings on the electricity bill > Eliminating penalties on reactive energy and decreasing kva demand. > Reducing power losses generated in the transformers and conductors of the installation. Example: Loss reduction in a 630 kva transformer PW = 6,500 W with an initial Power Factor = 0.7. With power factor correction, we obtain a final Power Factor = The losses become: 3,316 W, i.e. a reduction of 49 %. Increasing available power A high power factor optimizes an electrical installation by allowing better use of the components. The power available at the secondary of a MV/LV transformer can therefore be increased by fitting power factor correction equipment on the low voltage side. The table opposite shows the increased available power at the transformer output through improvement of the Power Factor from 0.7 to 1. Power factor Increased available power % % % % % % Reducing installation size Installing power factor correction equipment allows conductor cross-section to be reduced, since less current is absorbed by the compensated installation for the same active power. The opposite table shows the multiplying factor for the conductor cross-section with different power factor values. Power factor Cable crosssection multiplying factor Reducing voltage drops in the installation Installing capacitors allows voltage drops to be reduced upstream of the point where the power factor correction device is connected. This prevents overloading of the network and reduces harmonics, so that you will not have to overrate your installation. 5
14 Power Factor Correction guideline Method for determining compensation The selection of Power Factor Correction equipment can follow a 4-step process: Calculation of the required reactive energy. Selection of the compensation mode: - Central, for the complete installation - By sector - For individual loads, such as large motors. Selection of the compensation type: - Fixed, by connection of a fixed-value capacitor bank; - Automatic, by connection of a different number of steps, allowing adjustment of the reactive energy to the required value; - Dynamic, for compensation of highly fluctuating loads. Allowance for operating conditions and harmonics. Step 1: Calculation of the required reactive power DE90091.eps The objective is to determine the required reactive power Q c (kvar) to be installed, in order to improve the power factor cos φ and reduce the apparent power S. For φ < φ, we obtain: cos φ > cos φ and tan φ < tan φ. This is illustrated in the diagram opposite. Qc can be determined from the formula Qc = P. (tan φ - tan φ ), which is deduced from the diagram. Q c = power of the capacitor bank in kvar. P = active power of the load in kw. tan φ = tangent of phase shift angle before compensation. tan φ = tangent of phase shift angle after compensation. The parameters φ and tan φ can be obtained from billing data, or from direct measurement in the installation. The following table can be used for direct determination. Before compensation Reactive power (kvar) to be installed per kw of load, in order to get the required cos j or tan j tan j cos j tan j cos j Example: consider a 1000 kw motor with cos j = 0.8 (tan j = 0.75). In order to obtain cos j = 0.95, it is necessary to install a capacitor bank with a reactive power equal to k x P, i.e.: Qc = 0.42 x 1000 = 420 kvar. 6
15 Method for determining compensation Step 2: Selection of the compensation mode Supply Bus Transformer Circuit breaker The location of low-voltage capacitors in an installation constitutes the mode of compensation, which may be central (one location for the entire installation), by sector (section-by-section), at load level, or some combination of the latter two. In principle, the ideal compensation is applied at a point of consumption and at the level required at any moment in time. In practice, technical and economic factors govern the choice. IC CC GC GC IC IC IC The location for connection of capacitor banks in the electrical network is determined by: th e overall objective (avoid penalties on reactive energy relieve transformer or cables, avoid voltage drops and sags) the operating mode (stable or fluctuating loads) the foreseeable influence of capacitors on the network characteristics the installation cost. M M M M CC : Central Compensation GC : Group Compensation IC : Individual Compensation M : Motor Load Central compensation The capacitor bank is connected at the head of the installation to be compensated in order to provide reactive energy for the whole installation. This configuration is convenient for a stable and continuous load factor. Group compensation (by sector) The capacitor bank is connected at the head of the feeders supplying one particular sector to be compensated. This configuration is convenient for a large installation, with workshops having different load factors. Compensation of individual loads The capacitor bank is connected right at the inductive load terminals (especially large motors). This configuration is very appropriate when the load power is significant compared to the subscribed power. This is the ideal technical configuration, as the reactive energy is produced exactly where it is needed, and adjusted to the demand. 7
16 Power Factor Correction guideline Method for determining compensation Step 3: Selection of the compensation type Different types of compensation should be adopted depending on the performance requirements and complexity of control: Fixed, by connection of a fixed-value capacitor bank Automatic, by connection of a different number of steps, allowing adjustment of the reactive energy to the required value Dynamic, for compensation of highly fluctuating loads. Fixed compensation This arrangement uses one or more capacitor(s) to provide a constant level of compensation. Control may be: Manual: by circuit-breaker or load-break switch Semi-automatic: by contactor Direct connection to an appliance and switched with it. These capacitors are installed: At the terminals of inductive loads (mainly motors) At busbars supplying numerous small motors and inductive appliances for which individual compensation would be too costly In cases where the load factor is reasonably constant. Automatic compensation This kind of compensation provides automatic control and adapts the quantity of reactive power to the variations of the installation in order to maintain the targeted cos j. The equipment is installed at points in an installation where the active-power and/or reactive-power variations are relatively large, for example: on the busbars of a main distribution switchboard on the terminals of a heavily-loaded feeder cable. Where the kvar rating of the capacitors is less than or equal to 15 % of the power supply transformer rating, a fixed value of compensation is appropriate. Above the 15 % level, it is advisable to install an automatically-controlled capacitor bank. Control is usually provided by an electronic device (Power Factor Controller) which monitors the actual power factor and orders the connection or disconnection of capacitors in order to obtain the targeted power factor. The reactive energy is thus controlled by steps. In addition, the Power Factor Controller provides information on the network characteristics (voltage amplitude and distortion, power factor, actual active and reactive power ) and equipment status. Alarm signals are transmitted in case of malfunction. Connection is usually provided by contactors. For compensation of highly fluctuating loads use of active filters or Electronic Var Compensators(EVC) are recommened. Contact Schneider Electric for electronic compensation solutions. Dynamic compensation This kind of compensation is required when fluctuating loads are present, and voltage fluctuations have to be prevented. The principle of dynamic compensation is to associate a fixed capacitor bank and an electronic var compensator, providing either leading or lagging reactive currents. The result is continuously varying fast compensation, perfectly suitable for loads such as lifts, crushers, spot welding, etc. 8
17 Method for determining compensation + To know more about the influence of harmonics in electrical installations, see appendix page 66 Step 4: Allowing for operating conditions and harmonics Capacitors should be selected depending on the working conditions expected during their lifetime. Allowing for operating conditions The operating conditions have a great influence on the life expectancy of capacitors. The following parameters should be taken into account: Ambient Temperature ( C) Expected over-current, related to voltage disturbances, including maximum sustained overvoltage Maximum number of switching operations/year Required life expectancy. Allowing for harmonics Depending on the magnitude of harmonics in the network, different configurations should be adopted. Standard capacitors: when no significant non-linear loads are present. Harmonic rated capacitors used with detuned reactors. Applicable when a significant number of non-linear loads are present. Reactors are necessary in order to prevent the amplification of harmonic currents and avoid resonance. Active filters: when non-linear loads are predominant, use of active filters are recommended for harmonic mitigation. Solutions can be recommended based on computer simulations or on site measurement of the network. Capacitor selection Different ranges with different levels of ruggedness are proposed: "EasyCan": Capacitors for standard operating conditions, and when no significant non-linear loads are present. "VarPlus Can & Box": Capacitors for stringent operating conditions, particularly voltage disturbances, or when a few non-linear loads are present. The rated current of capacitors must be increased in order to cope with the circulation of harmonic currents. "VarPlus Box Energy": Specially designed capacitors, for harsh operating conditions, particularly high temperature. Capacitors with detuned reactors: applicable when a significant number of non-linear loads are present. Before After 9
18 Power Factor Correction guideline Low Voltage capacitors with detuned reactors Capacitors and reactors are configured in a series resonant circuit, tuned so that the series resonant frequency is below the lowest harmonic frequency present in the system Reactors should be associated with capacitor banks for Power Factor Correction in systems with significant non-linear loads, generating harmonics. Capacitors and reactors are configured in a series resonant circuit, tuned so that the series resonant frequency is below the lowest harmonic frequency present in the system. For this reason, this configuration is usually called Detuned Capacitor Bank, and the reactors are referred to as Detuned Reactors. The use of detuned reactors thus prevents harmonic resonance problems, avoids the risk of overloading the capacitors and helps reduce voltage harmonic distortion in the network. The tuning frequency can be expressed by the relative impedance of the reactor (in %), or by the tuning order, or directly in Hz. The most common values of relative impedance are 5.7, 7 and 14 % (14 % is used with high level of 3rd harmonic voltages). Relative impedance (%) Tuning order Tuning 0Hz (Hz) Tuning 60Hz (Hz) The selection of the tuning frequency of the reactor capacitor depends on several factors: Presence of zero-sequence harmonics (3, 9, ) Need for reduction of the harmonic distortion level Optimization of the capacitor and reactor components Frequency of ripple control system if any. To prevent disturbances of the remote control installation, the tuning frequency should be selected at a lower value than the ripple control frequency. In a detuned filter application, the voltage across the capacitors is higher than the system s rated voltage. In that case, capacitors should be designed to withstand higher voltages. Depending on the selected tuning frequency, part of the harmonic currents is absorbed by the detuned capacitor bank. In that case, capacitors should be designed to withstand higher currents, combining fundamental and harmonic currents. Effective reactive energy In the pages relating to detuned capacitor banks, the reactive energy (kvar) given in the tables is the resulting reactive energy provided by the combination of capacitors and reactors. Capacitor rated voltage Capacitors have been specially designed to operate in detuned bank configurations. Parameters such as the rated voltage, over-voltage and over-current capabilities have been improved, compared to standard configuration. 10
19 Rated voltage and current According to IEC standard, the rated voltage (U N ) of a capacitor is defined as the continuously admissible operating voltage. The rated current (I N ) of a capacitor is the current flowing through the capacitor when the rated voltage (U N ) is applied at its terminals, supposing a purely sinusoidal voltage and the exact value of reactive power (kvar) generated. Capacitor units shall be suitable for continuous operation at an r.m.s. current of (1.3 x I N ). In order to accept system voltage fluctuations, capacitors are designed to sustain over-voltages of limited duration. For compliance to the standard, capacitors are for example requested to sustain over-voltages equal to 1.1 times U N, 8 h per 24 h. VarPlus Can, VarPlus Box, VarPlus Box Energy and EasyCan capacitors have been designed and tested extensively to operate safely on industrial networks. The design margin allows operation on networks including voltage fluctuations and common disturbances. Capacitors can be selected with their rated voltage corresponding to the network voltage. For different levels of expected disturbances, different technologies are proposed, with larger design margin for capacitors adapted to the most stringent working conditions (VarPlus Can, VarPlus Box & VarPlus Box Energy). VarPlus Can, VarPlus Box, VarPlus Box Energy and EasyCan capacitors when used along with Detuned Reactors have to be selected with a rated voltage higher than network service voltage (U s ). In detuned filter applications, the voltage across the capacitor is higher than the network service voltage (U s ). The recommended rated voltage of capacitors to be used in detuned filter applications with respect to different network service voltage (U s ) and relative impedance is given in the table below. These values ensure a safe operation in the most stringent operating conditions. Less conservative values may be adopted, but a case by case analysis is necessary. Capacitor Rated Voltage U N (V) Network Service Voltage U S (V) 50 Hz 60 Hz Relative Impedance 5.7 (%)
20 Power Factor Correction guideline Capacitor selection guide Capacitors must be selected depending on the working conditions expected during their lifetime. Solution Description Recommended use for Max. condition EasyCan Standard capacitor > Networks with non significant N LL 10 % non-linear loads VarPlus Can & Box VarPlus Box Energy Available in can construction Heavy-duty capacitor Available in can and box construction Capacitor for special conditions Available in box construction > Standard over-current 1.5 I N > Standard operating 55 C (class D) temperature > Normal switching frequency 5,000 / year > Standard life expectancy Up to 100,000h* > A few non-linear loads N LL 20 % > Significant over-current 1.8 I N > Standard operating 55 C (class D) temperature > Significant switching 7,000 / year frequency > Long life expectancy Up to 130,000h* > Significant number of nonlinear N LL 25 % loads (up to 25 %) > Severe over-current 2.5 I N > Extreme temperature 70 C conditions > Very frequent switching 10,000 / year > Extra long life expectancy Up to 160,000h* * The maximum life expectancy is given considering standard operating conditions: rated voltage (U N ), rated current (I N ), 35 C ambient temperature. WARNING: the life expectancy will be reduced if capacitors are used in maximum working conditions. Since the harmonics are caused by non-linear loads, an indicator for the magnitude of harmonics is the ratio of the total power of non-linear loads to the power supply transformer rating. This ratio is denoted N LL, and is also known as G h /S n : N LL = Total power of non-linear loads (G h ) / Installed transformer rating (S n ). Example: Power supply transformer rating: S n = 630 kva Total power of non-linear loads: G h = 150 kva N LL = (150/630) x 100 = 24 % It is recommended to use Detuned Reactors with Harmonic Rated Capacitors (higher rated voltage than the network service voltage - see the Harmonic Application Tables) for N LL > 20 % and up to 50 %. Note: there is a high risk in selecting the capacitors based only on N LL as the harmonics in grid may cause current amplification and capacitors along with other devices may fail. Refer to page 66 for further details. 12
21 Construction of references Principle Capacitors B L R C H A B 4 0 Construction Range Power Voltage C = CAN B = BOX Power at 60 Hz 12.5 kvar at 60 Hz V V S = EasyCan H = VarPlus E = VarPlus Energy at 50 Hz 10.4 kvar at 50 Hz A = 50 Hz B = 60 Hz "000B" means: labelled only for 50 Hz V V V V V V V Example: BLRCS200A240B44 = EasyCan, 440 V, 20 kvar at 50 Hz and 24 kvar at 60 Hz Detuned reactors L V R A 6 9 T Detuned Reactor Relative impedance Power Freq. Voltage 05 = 5.7 % 07 = 7 % 14 = 14 % 12.5 kvar A = 50 Hz B = 60 Hz V V V V Example: LVR05125A69T = Detuned Reactor, 690 V, 5.7 %, 12.5 kvar, 50 Hz. 13
22
23 Low Voltage capacitors Contents Presentation Power Factor Correction guideline 3 Low Voltage capacitors 15 Offer Overview 16 EasyCan 18 EasyCan harmonic applications 22 EasyCan + Detuned Reactor + Contactor 23 VarPlus Can 26 VarPlus Can harmonic applications 31 VarPlus Can + Detuned Reactor + Contactor 32 Can type capacitor mechanical characteristics 34 VarPlus Box 36 VarPlus Box harmonic applications 40 VarPlus Box + Detuned Reactor + Contactor 41 VarPlus Box Energy 42 VarPlus Box Energy Harmonic applications 45 VarPlus Box Energy + Detuned Reactor + Contactor 46 Box Type Capacitor mechanical characteristics 47 Detuned reactors 51 Power Factor controllers 57 Contactors 61 Appendix 65 15
24 Low Voltage Capacitors Offer Overview EasyCan VarPlus Can Group of 3 EC Caps.jpg Group of 3 Caps.jpg EasyCan Construction Extruded aluminium can Voltage range 230 V V Power range 1-30 kvar (three-phase) Peak inrush Up to 200 x I n current Overvoltage 1.1 x U n 8 h every 24 h Overcurrent 1.5 x I n Mean life Up to 100,000 h expectancy Safety Self-healing + 3 phase pressure-sensitive disconnector (PSD) + non accessible inbuilt discharge device (50 V/1 min) Dielectric Metallized Polypropylene film with Zn/Al alloy Impregnation Non-PCB, Biodegradable soft resin Ambient min. -25 C max 55 C temperature Protection IP20(for fast-on and clamptite), indoor Mounting Upright Terminals Double fast-on + cable ( 10 kvar) CLAMPTITE - Three-phase terminal with electric shock protection (fingerproof) VarPlus Can Construction Extruded aluminium can Voltage range 230 V V Power range 1-50 kvar (three-phase) Peak inrush Up to 250 x I n current Overvoltage 1.1 x U n 8 h every 24 h Overcurrent 1.8 x I n Mean life Up to 130,000 h expectancy Safety Self-healing + 3 phase pressure-sensitive disconnector (PSD) independent of mechanical assembly+ non accessable inbuilt discharge device (50 V/1 min) Dielectric Metallized Polypropylene film with Zn/Al alloy with special profile metallization and wave cut Impregnation Non-PCB, Bio-degradable sticky resin(pu) Ambient min. -25 C max 55 C temperature Protection IP20(for fast-on and clamptite), indoor Mounting Upright, horizontal Terminals Double fast-on + cable ( 10 kvar) CLAMPTITE - Three-phase terminal with electric shock protection (finger-proof) Stud type terminal (> 30 kvar) 16
25 Offer Overview VarPlus Box VarPlus Box VarPlus Box Energy Construction Steel sheet enclosure Voltage range 380 V V 380 V V Power range (threephase) 5-60 kvar kvar Peak inrush current Up to 250 x I n Up to 350 x I n Overvoltage 1.1 x U n 8 h every 24 h Overcurrent 1.8 x I n 2.5 x I n Mean life expectancy Up to 130,000 h Up to 160,000 h Safety Self-healing + 3 phase pressure-sensitive disconnector (PSD) independent of mechanical assembly + inbuilt discharge device (50 V/1 min) + double enclosure protection (Aluminum can inside steel box) Dielectric Impregnation Metallized Polypropylene film with Zn/Al alloy with special profile metallization and wave cut Non-PCB, sticky (dry) Biodegradable resin Double metallized paper + Polypropylene film Non-PCB, oil Ambient temperature min. -25 C max 55 C min. -25 C max 70 C Protection IP20, Indoor Mounting Upright Terminals Bushing terminals designed for large cable termination 17
26 Low Voltage Capacitors EasyCan Group of 2 EC Caps.jpg An easy choice for savings which is optimized to deliver the performance you need. Suitable for standard operating conditions to deliver safe and reliable performance. Operating conditions For networks with insignificant non-linear loads: (N LL 10 %). Standard voltage disturbances. Standard operating temperature up to 55 C. Normal switching frequency up to /year. Maximum current (including harmonics) is 1.5 x I N. Easy installation & maintenance Optimized design for low weight, compactness and reliability to ensure easy installation and upto 20% space savings in cubicles. New CLAMPTITE terminals that allows maintained tightness. Non accessaile in-built discharge resistors to ensure safety. 1 point for mounting and earthing. 3 phase simultaneous safe disconnection at end of life. Stacked design and resin filled technology for better cooling. Safety Self-healing. Pressure-sensitive disconnector on all three phases. Discharge resistors fitted - non removable. Finger-proof CLAMPTITE terminals to reduce risk of accidental contact and to ensure firm termination (10 to 30 kvar). Technology Constructed internally with three single-phase capacitor elements assembled in an optimized design. Each capacitor element is manufactured with metallized polypropylene film. EasyCan The active capacitor elements are encapsulated in a specially formulated biodegradable, non-pcb, polyurethane soft resin which ensures thermal stability and heat removal from inside the capacitor. The unique finger-proof CLAMPTITE termination is fully integrated with discharge resistors and allows suitable access to tightening and allows cable termination without any loose connections. For lower ratings, double fast-on terminals with wires are provided. Benefits Easy installation Easy for reliablity and safe usage. Easy for quality assurance. Easy choice for building your solutions with other Schneider Electric components. Easy choice for savings. 18
27 EasyCan EasyCan03_Back.eps Technical specifications General characteristics Standards IEC /2 Voltage range Frequency Power range Losses (dielectric) Losses (total) 230 to 525 V 50 / 60 Hz 1 to 30 kvar < 0.2 W / kvar < 0.5 W / kvar Capacitance tolerance -5 %, +10 % Voltage test Between terminals 2.15 x U N (AC), 10 s Between terminal & container Impulse voltage Discharge resistor 3 kv (AC), 10 s or 3.66 kv (AC), 2 s 8 kv Fitted, standard discharge time 60 s Working conditions Ambient temperature -25 / 55 C (Class D) Humidity 95 % Altitude 2,000 m above sea level Overvoltage 1.1 x U N 8 h in every 24 h Overcurrent Up to 1.5 x I N Peak inrush current 200 x I N Switching operations (max.) Up to 5,000 switching operations per year Mean Life expectancy Up to 100,000 hrs Harmonic content withstand N LL 10 % Installation characteristics Mounting position Indoor, upright Fastening Earthing Terminals Safety features Safety Protection Construction Casing Dielectric Impregnation Threaded M12 stud at the bottom CLAMPTITE - three-way terminal with electric shock protection (finger-proof) & double fast-on terminal in lower kvar Self-healing + Pressure-sensitive disconnector + Discharge device IP20 (for fast-on and clamptite) Extruded Aluminium Can Metallized polypropylene film with Zn/Al alloy Biodegradable, Non-PCB, poly urethane soft resin WARNING HAZARD OF ELECTRICAL SHOCK Wait 5 minutes after isolating supply before handling Failure to follow these instructions can result in injury or equipment damage 19
28 Low Voltage Capacitors EasyCan Rated Voltage 240/260 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 230 V 240 V 260 V at 260 V 230 V 240 V 260 V at 260 V HC BLRCS027A033B MC BLRCS054A065B NC BLRCS063A075B NC BLRCS083A100B SC BLRCS109A130B24 Rated Voltage 380/400/415 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 380 V 400 V 415 V at 400 V 380 V 400 V 415 V at 400 V EC BLRCS010A012B DC BLRCS017A020B DC BLRCS020A024B DC BLRCS025A030B DC BLRCS030A036B DC BLRCS042A050B HC BLRCS050A060B HC BLRCS063A075B HC BLRCS075A090B LC BLRCS083A100B MC BLRCS104A125B NC BLRCS125A150B NC BLRCS139A167B NC BLRCS150A180B SC BLRCS167A200B SC BLRCS200A240B SC BLRCS208A250B SC BLRCS222A266B SC BLRCS250A300B VC BLRCS277A332B40 20
29 EasyCan Rated Voltage 440 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 400 V 415 V 440 V at 440 V 400 V 415 V 440 V at 440 V DC BLRCS030A036B HC BLRCS050A060B HC BLRCS075A090B LC BLRCS100A120B NC BLRCS125A150B NC BLRCS143A172B NC BLRCS150A180B SC BLRCS169A203B SC BLRCS182A218B SC BLRCS200A240B SC BLRCS250A300B SC BLRCS285A342B SC BLRCS303A364B44 Rated Voltage 480 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 400 V 415 V 480 V at 480 V 400 V 440 V 480 V at 480 V DC BLRCS042A050B HC BLRCS067A080B HC BLRCS075A090B LC BLRCS088A106B MC BLRCS104A125B NC BLRCS125A150B NC BLRCS144A173B NC BLRCS155A186B NC BLRCS170A204B SC BLRCS186A223B SC BLRCS208A250B SC BLRCS258A310B VC BLRCS288A346B VC BLRCS315A378B XC BLRCS339A407B48 Rated Voltage 525 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 415 V 480 V 525 V at 525 V 400 V 480 V 525 V at 525 V HC BLRCS050A060B MC BLRCS106A127B NC BLRCS125A150B NC BLRCS154A185B SC BLRCS200A240B SC BLRCS250A300B52 21
30 Low Voltage Capacitors EasyCan harmonic applications EasyCan capacitors are designed to work in slightly polluted networks with detuned reactors. 480 and 525V range of EasyCan is designed to work with detuned reactors in 400V. EasyCan 03.jpg Operating conditions For slightly polluted networks. Slight voltage disturbances. Need of switching frequency up to /year. Rated voltage In a detuned filter application, the voltage across the capacitors is higher than the network service voltage (U S ). Then, capacitors must be designed to withstand higher voltages. Depending on the selected tuning frequency, part of the harmonic currents are absorbed by the detuned capacitor bank. Then, capacitors must be designed to withstand higher currents, combining fundamental and harmonic currents. PE90154.eps The rated voltage of EasyCan capacitors is given in the table below, for different values of network service voltage and relative impedance. Detuned reactor + EasyCan Capacitor Rated Voltage U N (V) Relative Impedance (%) Network Service Voltage U S (V) 50 Hz 60 Hz In the following pages, the effective power (kvar) given in the tables is the reactive power provided by the combination of capacitors and reactors. 22
31 EasyCan + Detuned Reactor + Contactor + MCCB 28_PB eps EasyCan 04.jpg PE90154_L28_r.eps + + Network 400 V, 50 Hz Capacitor Voltage 480 V 5.7 % / 7 % Detuned Reactor Effective Q N Capacitor Ref. 5.7% fr = 210Hz 7% fr = 190Hz Switching: Protection: Power at Contactor Ref. Easypact CVS (kvar) 480 V D R Ref. D R Ref. (ICU=36kA)Ref BLRCS088A106B48 1 LVR05065A40T x 1 LVR07065A40T x 1 LC1D12 1 LV BLRCS170A204B48 1 LVR05125A40T x 1 LVR07125A40T x 1 LC1D18 1 LV BLRCS339A407B48 1 LVR05250A40T x 1 LVR07250A40T x 1 LC1D32 1 LV BLRCS339A407B48 2 LVR05500A40T x 1 LVR07500A40T x 1 LC1D80 1 LV BLRCS339A407B48 4 LVR05X00A40T x 1 LVR07X00A40T x 1 LC1D150 1 LV Network 400 V, 50 Hz Capacitor Voltage 480 V 14 % Detuned Reactor Effective Q N Capacitor Ref. 14% fr = 135Hz Switching: Protection: Power at Contactor Ref. Easypact CVS (kvar) 480 V D R Ref. (ICU=36kA)Ref BLRCS088A106B48 1 LVR14065A40T x 1 LC1D12 1 LV BLRCS155A186B48 1 LVR14125A40T x 1 LC1D18 1 LV BLRCS315A378B48 1 LVR14250A40T x 1 LC1D32 1 LV BLRCS315A378B48 2 LVR14500A40T x 1 LC1D80 1 LV BLRCS315A378B48 4 LVR14X00A40T x 1 LC1D150 1 LV Network 400 V, 50 Hz Capacitor Voltage 525 V 5.7 % / 7 % Detuned Reactor Effective Q N Capacitor Ref. 5.7% fr = 210Hz 7% fr = 190Hz Switching: Protection: Power at Contactor Ref. Easypact CVS (kvar) 525 V D R Ref. D R Ref. (ICU=36kA) Ref BLRCS106A127B52 1 LVR05065A40T x 1 LVR07065A40T x 1 LC1D12 1 LV BLRCS200A240B52 1 LVR05125A40T x 1 LVR07125A40T x 1 LC1D18 1 LV BLRCS200A240B52 2 LVR05250A40T x 1 LVR07250A40T x 1 LC1D32 1 LV BLRCS200A240B52 x 4 LVR05500A40T x 1 LVR07500A40T x 1 LC1D80 1 LV BLRCS200A240B52 x 8 LVR05X00A40T x 1 LVR07X00A40T x 1 LC1D150 1 LV Network 400 V, 50 Hz Capacitor Voltage 525 V 14 % Detuned Reactor Effective Q N Capacitor Ref. 14% fr = 135Hz Switching: Protection: Power at Contactor Ref. Easypact CVS (kvar) 525 V D R Ref. (ICU=36kA)Ref BLRCS106A127B52 1 LVR14065A40T x 1 LC1D12 1 LV BLRCS200A240B52 x 1 LVR14125A40T x 1 LC1D18 1 LV BLRCS200A240B52 x 2 LVR14250A40T x 1 LC1D32 1 LV BLRCS250A300B52 3 LVR14500A40T x 1 LC1D80 1 LV BLRCS250A300B52 6 LVR14X00A40T x 1 LC1D150 1 LV
32 Low Voltage Capacitors EasyCan + Detuned Reactor + Contactor + MCCB 28_PB eps EasyCan 04.jpg PE90154_L28_r.eps + + Network 400 V, 60 Hz Capacitor Voltage 480 V 5.7 % / 7 % Detuned Reactor Effective Q N Capacitor Ref. 5.7% fr = 250Hz 7% fr = 230Hz Switching: Protection: Power at Contactor Ref. Easypact CVS (kvar) 480 V D R Ref. D R Ref. (ICU=36kA)Ref BLRCS144A173B48 1 LVR05125B40T 1 LVR07125B40T 1 LC1D18 1 LV BLRCS288A346B48 1 LVR05250B40T 1 LVR07250B40T 1 LC1D32 1 LV BLRCS288A346B48 2 LVR05500B40T 1 LVR07500B40T 1 LC1D80 1 LV BLRCS288A346B48 4 LVR05X00B40T 1 LVR07X00B40T 1 LC1D150 1 LV Network 400 V, 60 Hz Capacitor Voltage 480 V 14 % Detuned Reactor Effective Q N Capacitor Ref. 14% fr = 160Hz Switching: Protection: Power at Contactor Ref. Easypact CVS (kvar) 480 V D R Ref. (ICU=36kA)Ref BLRCS136A163B48 1 LVR14125B40T 1 LC1D18 1 LV BLRCS258A310B48 1 LVR14250B40T 1 LC1D32 1 LV BLRCS258A310B48 2 LVR14500B40T 1 LC1D80 1 LV BLRCS258A310B48 4 LVR14X00B40T 1 LC1D150 1 LV
33 25
34 Low Voltage Capacitors VarPlus Can A safe, reliable, high-performance and flexible solution for power factor correction in stringent operating conditions to maximise your savings Operating conditions For networks with insignificant non-linear loads: (N LL < 20 %). Significant voltage disturbances. Standard operating temperature up to 55 C. Normal switching frequency up to /year. Over current handling(including harmonics) up to 1.8 x I N. Group of 3 Caps.jpg High performance and flexibility with VarPlus Can Power ratings up to 50kvar in single can and compactness across the range to reduce your cubicle space up to 40%. Build your type tested Schneider electric solution with VarPlus Can Prisma, Blokset and Okken. In-built user assistance and warnings on the product for a delight user experience. Flexibility in Vertical and horizontal mounting. 3 Phase disconnection of Pressure sensitive disconnector at the end of life which is independent of mechanical assembly for safety and reliability. Use of special conductors in stacked design impregnated in resin to ensure better cooling and enhanced life. Metallized polypropylene with wave cut and heavy edge technology to handle over current conditions in harsh environments. Specially formulated sticky resin to increase the mechanical stability of capacitor elements for higher rating capacitors to ensure better cooling and extended life. Designed for high performance in harsh environment to ensure 30% extended life compared to standard capacitors. VarPlus Can Safety Self-healing. Pressure-sensitive disconnector on all three phases independent of mechanical assembly. Tamper resistant non-assessible in-built discharge resistors. Unique Finger-proof New CLAMPTITE terminals to reduce risk of accidental contact and to ensure firm termination (10 to 30 kvar) and maintained tightness. Special film resistivity and metallization profile for higher thermal efficiency, lower temperature rise and enhanced life expectancy. Technology VarPlus Can capacitors are constructed internally with three single-phase capacitor elements. Each capacitor element is manufactured with metallized polypropylene film as the dielectric, having features such as heavy edge, slope metallization and wave-cut profile to ensure increased current handling capacity and reduced temperature rise. Sticky resign which give good thermal conductivity and mechanical stability allows the capacitor to carry higher overloads. Stud type terminals are designed for handling higher currents for capacitors more than 30kvar. The unique finger-proof CLAMPTITE termination is fully integrated with discharge resistors, allowing suitable access for tightening and ensuring cable termination without any loose connections. For lower ratings, double fast-on terminals with wires are provided. Benefits Save panel space due to its compact design and range. High Performance & Long life. High over current handling. Unique disconnection system and in-built discharge device. Flexibility in installation - upright and horizontal. 26
35 VarPlus Can VarPlus Can 02_Back.eps Technical specifications General characteristics Standards IEC /2 Voltage range Frequency Power range Losses (dielectric) Losses (total) 230 to 830 V 50 / 60 Hz 1 to 50 kvar < 0.2 W / kvar < 0.5 W / kvar Capacitance tolerance -5 %, +10 % Voltage test Between terminals 2.15 x U N (AC), 10 s Discharge resistor Between terminal & container Impulse voltage Working conditions Ambient temperature -25 / 55 C (Class D) 525 V: 3 kv (AC), 10 s or 3.66 kv (AC), 2 s > 525 V: 3.66 kv (AC), 10 s or 4.4 kv (AC), 2 s 690 V: 8 kv > 690 V: 12 kv Fitted, standard discharge time 60 s Humidity 95 % Altitude 2,000 m above sea level Overvoltage 1.1 x U N 8 h in every 24 h Overcurrent Up to 1.8 x I N Peak inrush current 250 x I N Switching operations (max.) Up to 7,000 switching operations per year Mean Life expectancy Up to 130,000 hrs Harmonic content withstand N LL 20 % Installation characteristics Mounting position Indoor, upright & horizontal Fastening Earthing Terminals Threaded M12 stud at the bottom CLAMPTITE - three-way terminal with electric shock protection (finger-proof) and, double fast-on terminal in lower kvar and stud type above 30kvar Safety features Safety Self-healing + Pressure-sensitive disconnector + Discharge device Protection Construction Casing Dielectric Impregnation IP20 (for fast-on and clamptite terminal) Extruded Aluminium Can Metallized polypropylene film with Zn/Al alloy. Special resistivity & profile, special edge (wave-cut) Non-PCB, polyurethene sticky resin (Dry) WARNING HAZARD OF ELECTRICAL SHOCK Wait 5 minutes after isolating supply before handling Failure to follow these instructions can result in injury or equipment damage 27
36 Low Voltage Capacitors VarPlus Can Rated Voltage 240/260 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 230 V 240 V 260 V at 260 V 230 V 240 V 260 V at 260 V HC BLRCH021A025B HC BLRCH027A033B HC BLRCH042A050B MC BLRCH054A065B RC BLRCH063A075B RC BLRCH083A100B TC BLRCH109A130B TC BLRCH117A140B TC BLRCH131A157B24 Rated Voltage 380/400/415 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 380 V 400 V 415 V at 400 V 380 V 400 V 415 V at 400 V DC BLRCH025A030B DC BLRCH030A036B HC BLRCH050A060B HC BLRCH063A075B HC BLRCH075A090B LC BLRCH083A100B MC BLRCH104A125B RC BLRCH125A150B RC BLRCH150A180B TC BLRCH167A200B TC BLRCH200A240B TC BLRCH208A250B TC BLRCH250A300B VC BLRCH300A360B VC BLRCH333A400B YC BLRCH400A480B YC BLRCH417A500B YC BLRCH500A000B40 Rated Voltage 440 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 400 V 415 V 440 V at 440 V 400 V 415 V 440 V at 440 V HC BLRCH050A060B HC BLRCH075A090B MC BLRCH100A120B RC BLRCH125A150B RC BLRCH143A172B RC BLRCH150A180B TC BLRCH169A203B TC BLRCH182A218B TC BLRCH200A240B TC BLRCH250A300B VC BLRCH285A342B VC BLRCH303A000B VC BLRCH315A378B VC BLRCH335A401B XC BLRCH400A480B YC BLRCH500A000B YC BLRCH571A000B44 28
37 VarPlus Can Rated Voltage 480 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 400 V 415 V 480 V at 480 V 400 V 440 V 480 V at 480 V DC BLRCH042A050B HC BLRCH050A060B HC BLRCH075A090B LC BLRCH088A106B MC BLRCH104A125B MC BLRCH113A136B RC BLRCH125A150B RC BLRCH136A163B RC BLRCH144A173B RC BLRCH155A186B RC BLRCH170A204B TC BLRCH180A216B TC BLRCH192A230B TC BLRCH208A250B TC BLRCH227A272B TC BLRCH258A310B VC BLRCH288A346B VC BLRCH315A378B XC BLRCH339A407B48 Rated Voltage 525 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 415 V 480 V 525 V at 525 V 400 V 480 V 525 V at 525 V HC BLRCH050A060B LC BLRCH100A120B MC BLRCH106A127B RC BLRCH125A150B RC BLRCH150A180B RC BLRCH172A206B TC BLRCH185A222B TC BLRCH200A240B TC BLRCH250A300B VC BLRCH309A371B VC BLRCH344A413B VC BLRCH377A452B XC BLRCH400A480B52 Rated Voltage 575 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 480 V 550 V 575 V at 575 V 480 V 550 V 575 V at 575 V RC BLRCH120A144B TC BLRCH150A180B VC BLRCH292A350B57 29
38 Low Voltage Capacitors VarPlus Can Rated Voltage 600 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 480 V 550 V 600 V at 600 V 480 V 550 V 600 V at 600 V RC BLRCH083A100B TC BLRCH104A125B TC BLRCH125A150B VC BLRCH208A250B # YC BLRCH250A300B60 # # YC BLRCH417A500B60 # Rated Voltage 690 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 480 V 600 V 690 V at 690 V 480 V 600 V 690 V at 690 V RC BLRCH111A133B RC BLRCH125A150B TC BLRCH138A165B TC BLRCH150A180B TC BLRCH200A240B VC BLRCH250A300B VC BLRCH276A331B VC BLRCH300A360B # YC BLRCH400A480B69 # # YC BLRCH520A624B69 # Rated Voltage 830 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 600 V 690 V 830 V at 830 V 600 V 690 V 830 V at 830 V # VC BLRCH171A205B83 # # Available in star connection. 30
39 VarPlus Can harmonic applications PE90154.eps VarPlus Can capacitors are designed for applications where higher number of non-linear loads are present. Higher current carrying capacity in VarPlus Can allows the operations in stringent conditions. + Detuned reactor VarPlus Can VarPlus Can 04.jpg Operating conditions For networks with a large number of non-linear loads (N LL < 50 %). Significant voltage disturbances. Significant switching frequency up to /year. Rated voltage In a detuned filter application, the voltage across the capacitors is higher than the network service voltage (U S ). Then, capacitors must be designed to withstand higher voltages. Depending on the selected tuning frequency, part of the harmonic currents are absorbed by the detuned capacitor bank. Then, capacitors must be designed to withstand higher currents, combining fundamental and harmonic currents. The rated voltage of VarPlus Can capacitors is given in the table below, for different values of network service voltage and relative impedance. Capacitor Rated Voltage U N (V) Network Service Voltage U S (V) 50 Hz 60 Hz Relative Impedance 5.7 (%) In the following pages, the effective power (kvar) given in the tables is the reactive power provided by the combination of capacitors and reactors. 31
40 Low Voltage Capacitors VarPlus Can + Detuned Reactor + Contactor + MCCB 28_PB eps VarPlus Can 02.jpg PE90154_L28_r.eps + + Network 400 V, 50 Hz Capacitor Voltage 480 V 5.7 % / 7 % Detuned Reactor Effective Q N Capacitor Ref. 5.7% fr = 210Hz 7% fr = 190Hz Switching: Protection: Power at Contactor Ref. Compact NSX (kvar) 480 V D R Ref. D R Ref. (ICU=50kA) Ref BLRCH088A106B48 1 LVR05065A40T x 1 LVR07065A40T x 1 LC1D12 1 LV BLRCH170A204B48 1 LVR05125A40T x 1 LVR07125A40T x 1 LC1D18 1 LV BLRCH339A407B48 1 LVR05250A40T x 1 LVR07250A40T x 1 LC1D32 1 LV BLRCH339A407B48 2 LVR05500A40T x 1 LVR07500A40T x 1 LC1D80 1 LV BLRCH339A407B48 4 LVR05X00A40T x 1 LVR07X00A40T x 1 LC1D150 1 LV Network 400 V, 50 Hz Capacitor Voltage 480 V 14 % Detuned Reactor Effective Q N Capacitor Ref. 14% fr = 135Hz Switching: Protection: Power at Contactor Ref. Compact NSX (kvar) 480 V D R Ref. (ICU=50kA) Ref BLRCH088A106B48 1 LVR14065A40T x 1 LC1D12 1 LV BLRCH155A186B48 1 LVR14125A40T x 1 LC1D18 1 LV BLRCH315A378B48 1 LVR14250A40T x 1 LC1D32 1 LV BLRCH315A378B48 2 LVR14500A40T x 1 LC1D80 1 LV BLRCH315A378B48 4 LVR14X00A40T x 1 LC1D150 1 LV Network 400 V, 50 Hz Capacitor Voltage 525 V 5.7 % / 7 % Detuned Reactor Effective Q N Capacitor Ref. 5.7% fr = 210Hz 7% fr = 190Hz Switching: Protection: Power at Contactor Ref. Compact NSX (kvar) 525 V D R Ref. D R Ref. (ICU=50kA) Ref BLRCH106A127B52 1 LVR05065A40T x 1 LVR07065A40T x 1 LC1D12 1 LV BLRCH200A240B52 1 LVR05125A40T x 1 LVR07125A40T x 1 LC1D18 1 LV BLRCH400A480B52 1 LVR05250A40T x 1 LVR07250A40T x 1 LC1D32 1 LV BLRCH400A480B52 2 LVR05500A40T x 1 LVR07500A40T x 1 LC1D80 1 LV BLRCH400A480B52 4 LVR05X00A40T x 1 LVR07X00A40T x 1 LC1D150 1 LV Network 400 V, 50 Hz Capacitor Voltage 525 V 14 % Detuned Reactor Effective Q N Capacitor Ref. 14% fr = 135Hz Switching: Protection: Power at Contactor Ref. Compact NSX (kvar) 525 V D R Ref. (ICU=50kA) Ref BLRCH106A127B52 1 LVR14065A40T x 1 LC1D12 1 LV BLRCH185A222B52 1 LVR14125A40T x 1 LC1D18 1 LV BLRCH377A452B52 1 LVR14250A40T x 1 LC1D32 1 LV BLRCH377A452B52 2 LVR14500A40T x 1 LC1D80 1 LV BLRCH377A452B52 4 LVR14X00A40T x 1 LC1D150 1 LV Network 690 V, 50 Hz Capacitor Voltage 830 V 5.7 % / 7 % Detuned Reactor Effective Q N Capacitor Ref. 5.7% fr = 210Hz 7% fr = 190Hz Switching: Protection: Power at Contactor Ref. Compact NSX (kvar) 830 V D R Ref. D R Ref. (ICU=10kA) Ref BLRCH171A205B83 1 LVR05125A69T 1 LVR07125A69T 1 LC1D12 1 LV BLRCH171A205B83 2 LVR05250A69T 1 LVR07250A69T 1 LC1D25 1 LV BLRCH171A205B83 4 LVR05500A69T 1 LVR07500A69T 1 LC1D50 1 LV BLRCH171A205B83 8 LVR05X00A69T 1 LVR07X00A69T 1 LC1D80 1 LV
41 VarPlus Can + Detuned Reactor + Contactor + MCCB 28_PB eps VarPlus Can 02.jpg PE90154_L28_r.eps Network 400 V, 60 Hz Capacitor Voltage 480 V 5.7 % / 7 % Detuned Reactor Effective Q N Capacitor Ref. 5.7% fr = 250Hz 7% fr = 230Hz Switching: Protection: Power at Contactor Ref. Compact NSX (kvar) 480 V D R Ref. D R Ref. (ICU=50kA) Ref BLRCH144A173B48 1 LVR05125B40T 1 LVR07125B40T 1 LC1D12 1 LV BLRCH288A346B48 1 LVR05250B40T 1 LVR07250B40T 1 LC1D32 1 LV BLRCH288A346B48 2 LVR05500B40T 1 LVR07500B40T 1 LC1D80 1 LV BLRCH288A346B48 4 LVR05X00B40T 1 LVR07X00B40T 1 LC1D150 1 LV Network 400 V, 60 Hz Capacitor Voltage 480 V 14 % Detuned Reactor Effective Q N Capacitor Ref. 14% fr = 160Hz Switching: Protection: Power at Contactor Ref. Compact NSX (kvar) 480 V D R Ref. (ICU=50kA) Ref BLRCH136A163B48 1 LVR14125B40T 1 LC1D18 1 LV BLRCH258A310B48 1 LVR14250B40T 1 LC1D25 1 LV BLRCH258A310B48 2 LVR14500B40T 1 LC1D50 1 LV BLRCH258A310B48 4 LVR14X00B40T 1 LC1D150 1 LV Network 480 V, 60 Hz Capacitor Voltage 575 V 5.7 % Detuned Reactor Effective Q N Capacitor Ref. 5.7% fr = 250Hz Switching: Protection: Power at Contactor Ref. Compact NSX (kvar) 575 V D R Ref. (ICU=50kA) Ref BLRCH150A180B57 1 LVR05125B48T 1 LC1D12 1 LV BLRCH292A350B57 1 LVR05250B48T 1 LC1D25 1 LV BLRCH292A350B57 2 LVR05500B48T 1 LC1D50 1 LV BLRCH292A350B57 4 LVR05X00B48T 1 LC1D115 1 LV Network 600 V, 60 Hz Capacitor Voltage 690 V 5.7 % Detuned Reactor Effective Q N Capacitor Ref. 5.7% fr = 250Hz Switching: Protection: Power at R Ref. Contactor Ref. Compact NSX (kvar) 690 V (ICU=20kA) Ref BLRCH138A165B69 1 LVR05125B60T 1 LC1D12 1 LV BLRCH276A331B69 1 LVR05250B60T 1 LC1D25 1 LV BLRCH520A624B69 1 LVR05500B60T 1 LC1D50 1 LV BLRCH520A624B69 2 LVR05X00B60T 1 LC1D115 1 LV
42 Low Voltage Capacitors Can type capacitors mechanical characteristics Case Code: DC, HC & LC Faston.eps Creepage distance Clearance Expansion (a) min.16 mm min.16 mm max.10 mm Mounting details (for M10/M12 mounting stud) Torque Toothed washer Hex nut Terminal assembly Ht. (t) M10: 7 N.m M12: 10 N.m M10/M12 M10/M12 50 mm Size (d) TS TH Ø 50 M10 10 mm Case Code: DC, EC, FC, HC & LC. Ø 63 M12 13 mm Ø 70 M12 16 mm Case code Diameter d Height h Height h + t DC EC FC HC LC Weight (kg) Case Code: MC, NC, RC & SC Clamptite_75 dia.eps Creepage distance Clearance Expansion (a) min.13 mm min.13 mm max.12 mm Mounting details (for M12 mounting stud) Torque T = 10 Nm Toothed washer J12.5 DIN 6797 Hex nut BM12 DIN 439 Terminal screw M5 Terminal assembly Ht. (t) 30 mm Case code Diameter d Height h Height h + t MC NC RC SC Weight (kg) Case Code: MC, NC, RC & SC. 34
43 clamptite-136.eps Case Code: TC, UC & VC Creepage distance Clearance Expansion (a) min.13 mm min.13 mm max.12 mm Mounting details (for M12 mounting stud) Torque T = 10 Nm Toothed washer J12.5 DIN 6797 Hex nut BM12 DIN 439 Terminal screw M5 Terminal assembly Ht. (t) 30 mm Case code Diameter d Height h Height h + t TC UC VC Weight (kg) Case Code: TC, UC & VC. Case Code: XC & YC stud.eps Creepage distance Clearance Expansion (a) min.13 mm 34 mm max.17 mm Mounting details (for M12 mounting stud) Torque T = 10 Nm Toothed washer J12.5 DIN 6797 Hex nut BM12 DIN 439 Terminal screw M10 Terminal assembly Ht. (t) 43 mm Case code Diameter d Height h Height h + t XC YC Weight (kg) Case Code: XC & YC. 35
44 Low Voltage Capacitors VarPlus Box PE90137 A robust, safe, reliable and high-performance solution for power factor correction in standard operating conditions. Operating conditions Optimum solution for stand alone PF compensation For networks with significant non-linear loads (NLL 20 %). Standard operating temperature up to 55 C. Significant number of switching operations up to 7,000/year. Long life expectancy up to 130,000 hours. VarPlus Box Answer for high performance with robustness Robustness Double metallic protection. Mechanically well suited for stand-alone installations. Safety Its unique safety feature electrically disconnects the capacitors safely at the end of their useful life. The disconnectors are installed on each phase, which makes the capacitors very safe, in addition to the protective steel enclosure. Use of Aluminum inside the steel enclosure eliminates the risk of any fire hazards unlike with plastic cells. High performance Heavy edge metallization/wave-cut edge to ensure high inrush current capabilities and high current handling. Special resistivity and profile metallization for better self-healing & enhanced life. Technology Constructed internally with three single-phase capacitor elements. VarPlus Box The design is specially adapted for mechanical stability. The enclosures of the units are designed to ensure that the capacitors operate reliably in hot and humid tropical conditions, without the need of any additional ventilation louvres (see technical specifications). Special attention is paid to equalization of temperatures within the capacitor enclosures since this gives better overall performance. Benefits Robustness with double metal protection (Aluminum cans inside steel box) Suitable for individual compensation with stand alone installation. Direct connection to a machine, in harsh environmental conditions. Dual safety Pressure Sensitive Disconnector(PSD) in aluminum cans with metal enclosure 36
45 VarPlus Box Technical specifications General characteristics Standards IEC /2 Voltage range Frequency Power range Losses (dielectric) Losses (total) 400 to 830 V 50 / 60 Hz 5 to 60 kvar < 0.2 W / kvar < 0.5 W / kvar Capacitance tolerance -5 %, +10 % Voltage test Between terminals 2.15 x U N (AC), 10 s Discharge resistor Between terminal & container Impulse voltage Working conditions Ambient temperature -25 / 55 C (Class D) 525 V: 3 kv (AC), 10 s or 3.66 kv (AC), 2 s > 525 V: 3.66 kv (AC), 10 s or 4.4 kv (AC), 2 s 690 V: 8 kv > 690 V: 12 kv Fitted, standard discharge time 60 s Humidity 95 % Altitude 2,000 m above sea level Overvoltage 1.1 x U N 8h in every 24 h Overcurrent Up to 1.8 x I N Peak inrush current 250 x I N Switching operations (max.) Up to 7,000 switching operations per year Mean Life expectancy Up to 130,000 hrs Harmonic content withstand N LL 20 % Installation characteristics Mounting position Indoor, upright Fastening Earthing Terminals Safety features Safety Protection Construction Casing Dielectric Impregnation Mounting cleats Bushing terminals designed for large cable termination Self-healing + Pressure-sensitive disconnector for each phase + Discharge device IP20 Sheet steel enclosure Metallized polypropylene film with Zn/Al alloy. special resistivity & profile. Special edge (wave-cut) Non-PCB, polyurethene sticky resin. WARNING HAZARD OF ELECTRICAL SHOCK Wait 5 minutes after isolating supply before handling Failure to follow these instructions can result in injury or equipment damage 37
46 Low Voltage Capacitors VarPlus Box Rated Voltage 380/400/415 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 380 V 400 V 415 V at 400 V 380 V 400 V 415 V at 400 V AB BLRBH050A060B AB BLRBH083A100B AB BLRBH104A125B AB BLRBH125A150B GB BLRBH151A181B GB BLRBH201A241B GB BLRBH208A250B GB BLRBH250A300B IB BLRBH417A500B IB BLRBH500A000B40 Rated Voltage 480 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 400 V 415 V 480 V at 480 V 400 V 440 V 480 V at 480 V AB BLRBH088A106B AB BLRBH104A125B AB BLRBH125A150B GB BLRBH156A187B GB BLRBH171A205B GB BLRBH208A250B IB BLRBH258A310B IB BLRBH288A346B IB BLRBH315A378B IB BLRBH339A407B IB BLRBH417A500B IB BLRBH619A000B48 Rated Voltage 525 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 415 V 480 V 525 V at 525 V 400 V 480 V 525 V at 525 V AB BLRBH100A120B AB BLRBH125A150B GB BLRBH250A300B IB BLRBH400A480B52 Rated Voltage 600 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 480 V 550 V 600 V at 600 V 480 V 550 V 600 V at 600 V AB BLRBH083A100B AB BLRBH104A125B AB BLRBH125A150B GB BLRBH167A200B GB BLRBH208A250B60 38
47 VarPlus Box Rated Voltage 690 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 480 V 600 V 690 V at 690 V 480 V 600 V 690 V at 690 V AB BLRBH138A165B GB BLRBH151A181B GB BLRBH200A240B GB BLRBH276A331B69 Rated Voltage 830 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 600 V 690 V 830 V at 830 V 600 V 690 V 830 V at 830 V GB BLRBH341A409B83 39
48 Low Voltage Capacitors VarPlus Box harmonic applications VarPlus Box capacitors are designed for applications where higher number of non-linear loads are present. Higher current carrying capacity in VarPlus Box allows the operations in stringent conditions. VarPlus Box capactiors are dedicated for standalone applications. Operating conditions For networks with a large number of non-linear loads (N LL < 50 %). Significant voltage disturbances. Very frequent switching operations, up to 7,000/year. PE90154+PE90134_r.eps Rated voltage In a detuned filter application, the voltage across the capacitors is higher than the network service voltage (U S ). Then, capacitors must be designed to withstand higher voltages. Depending on the selected tuning frequency, part of the harmonic currents is absorbed by the detuned capacitor bank. Then, capacitors must be designed to withstand higher currents, combining fundamental and harmonic currents. + Detuned reactor VarPlus Box The rated voltage of VarPlus Box capacitors is given in the table below, for different values of network service voltage and relative impedance. Capacitor Rated Voltage U N (V) Network Service Voltage U s (V) 50 Hz 60 Hz Relative Impedance 5.7 (%) In the following pages, the effective power (kvar) given in the tables is the reactive power provided by the combination of capacitors and reactors. 40
49 VarPlus Box + Detuned Reactor + Contactor + MCCB PE90154_L28_r.eps PE90134_L28_r.eps + Network 400 V, 50 Hz Capacitor Voltage 480 V 5.7 % / 7 % Detuned Reactor Effective Q N Capacitor Ref. 5.7% fr = 210Hz 7% fr = 190Hz Switching: Protection: Power at Contactor Ref. Compact NSX (kvar) 480 V D R Ref. D. R Ref. (ICU=50kA) Ref BLRBH171A205B48 1 LVR05125A40T x 1 LVR07125A40T x 1 LC1D18 1 LV BLRBH339A407B48 1 LVR05250A40T x 1 LVR07250A40T x 1 LC1D32 1 LV BLRBH339A407B48 2 LVR05500A40T x 1 LVR07500A40T x 1 LC1D80 1 LV BLRBH339A407B48 4 LVR05X00A40T x 1 LVR07X00A40T x 1 LC1D150 1 LV Network 400 V, 50 Hz Capacitor Voltage 480 V 14 % Detuned Reactor Effective Power (kvar) Q N Capacitor Ref. 14% fr = 135Hz Switching: at Contactor Ref. 480 V D R Ref. Protection: Compact NSX (ICU=50kA) Ref BLRBH156A187B48 1 LVR14125A40T x 1 LC1D18 1 LV BLRBH315A378B48 1 LVR14250A40T x 1 LC1D32 1 LV BLRBH619A000B48 1 LVR14500A40T x 1 LC1D80 1 LV BLRBH619A000B48 2 LVR14X00A40T x 1 LC1D150 1 LV Network 690 V, 50 Hz Capacitor Voltage 830 V 5.7 % / 7 % Reactor Effective Power (kvar) Q N at 830 V Capacitor Ref. 5.7% fr = 210Hz 7% fr = 190Hz Switching: Contactor Ref. D R Ref. D. R Ref. Protection: Compact NSX ((ICU=10kA) BLRBH341A409B83 1 LVR05250A69T 1 LVR07250A69T 1 LC1D25 1 LV BLRBH341A409B83 2 LVR05500A69T 1 LVR07500A69T 1 LC1D50 1 LV BLRBH341A409B83 4 LVR05X00A69T 1 LVR07X00A69T 1 LC1D80 1 LV PE90158_L20_r copy.eps Network 400 V, 60 Hz Capacitor Voltage 480 V 5.7 % / 7 % Detuned Reactor Effective Power (kvar) Q N at 480 V Capacitor Ref. 5.7% fr = 250Hz 7% fr = 230Hz Switching: Contactor D R Ref. D. R Ref. Ref. Protection: Compact NSX (ICU=50kA) Ref BLRBH288A346B48 1 LVR05250B40T 1 LVR07250B40T 1 LC1D32 1 LV BLRBH288A346B48 2 LVR05500B40T 1 LVR07500B40T 1 LC1D80 1 LV BLRBH288A346B48 4 LVR05X00B40T 1 LVR07X00B40T 1 LC1D150 1 LV PB eps + Network 400 V, 60 Hz Capacitor Voltage 480 V 14 % Detuned Reactor Effective Power (kvar) Q N at 480 V Capacitor Ref. 14% fr = 160Hz Switching: Contactor D R Ref. Ref. Protection: Compact NSX (ICU=50kA) Ref BLRBH258A310B48 1 LVR14250B40T 1 LC1D25 1 LV BLRBH258A310B48 2 LVR14500B40T 1 LC1D50 1 LV BLRBH258A310B48 4 LVR14X00B40T 1 LC1D150 1 LV Network 600 V, 60 Hz Capacitor Voltage 690 V 5.7 % Detuned Reactor Effective Power (kvar) Q N at 690 V Capacitor Ref. 5.7% fr = 250Hz Switching: Contactor D R Ref. Ref. Protection: Compact NSX (ICU=20kA) Ref BLRBH276A331B69 1 LVR05250B60T 1 LC1D25 1 LV BLRBH276A331B69 2 LVR05500B60T 1 LC1D50 1 LV BLRBH276A331B69 4 LVR05X00B60T 1 LC1D115 1 LV
50 Low Voltage Capacitors VarPlus Box Energy A unique solution for harsh environments which operates up to 70 C delivering extra safety, reliability and high-performance. Operating conditions For networks with significant non-linear loads: (NLL < 25 %) and severe voltage disturbances. Highest operating temperature (up to 70 C). High switching frequency, up to 10,000/year Maximum current withstand 2.5 x I N. VarPlus Box Energy Unique solution for higher operating temperature Made for harsh environments Special technology Double metalized paper impregnated in oil followed by a unique processing cycle - to deliver high performance in the harsh environments Suitable for high operating temperatures (up to 70 C). Robustness Double metallic protection. Mechanically well suited for stand-alone installations. Safety Its unique safety feature electrically disconnects the capacitors safely at the end of their useful life. The disconnectors are installed on each phase, which makes the capacitors very safe, in addition to the protective steel enclosure. Use of Aluminum inside the steel enclosure eliminates the risk of any fire hazards unlike with plastic cells. VarPlus Box Energy High performance Double metalized paper dielectric ensure maximum continuous current up to 2.5 x I N. Oil acts as a cooling media for the elements to minimize the risk of hot spot generation and increase the life of capacitor. Technology Special technology of double metalized paper impregnated in oil to provide extra long life for your capacitor needs in worst environments. Constructed internally with three single-phase capacitor elements. The design is specially adapted for mechanical stability. The enclosures of the units are designed to ensure that the capacitors operate reliably in hot and humid tropical conditions, without the need of any additional ventilation louvres (see technical specifications). Energy capacitors are the only technology which is capable of giving the longest life, highest overload limits and the highest operating ambient temperature due to use of the combination of polypropylene film and metallized paper. Benefits Life expectancy up to 160,000hrs Operating temperature up to 70 C Designed for harsh environments Robustness with double metal protection (Aluminum cans inside steel box) Dual safety - PSD in aluminum cans with metal enclosure 42
51 VarPlus Box Energy Technical specifications General characteristics Standards IEC /-2 Voltage range Frequency Power range Losses (dielectric) Losses (total) 400 to 525 V 50 / 60 Hz 10 to 60 kvar < 0.2 W / kvar < 0.5 W / kvar Capacitance tolerance -5 %, +10 % Voltage test Between terminals 2.15 x U N (AC), 10 s Between terminal & container Impulse voltage Discharge resistor Working conditions Ambient temperature -25 / 70 C 3 kv (AC), 10 s or 3.66 kv (AC), 2 s 8 kv Fitted, standard discharge time 60 s Humidity 95 % Altitude 2,000 m above sea level Overvoltage 1.1 x U N 8 h in every 24 h Overcurrent Up to 2.5 x I N Peak inrush current 350 x I N Switching operations (max.) Up to 10,000 switching operations per year Mean Life expectancy Up to 160,000 hrs Harmonic content withstand N LL 25 % Installation characteristics Mounting position Indoor & upright Fastening Earthing Terminals Safety features Safety Protection Construction Casing Dielectric Impregnation Mounting cleats Bushing terminals designed for large cable termination Self-healing + Pressure-sensitive disconnector for each phase + Discharge device IP20 Sheet steel enclosure Double metallized paper + polypropylene film Non-PCB, oil WARNING HAZARD OF ELECTRICAL SHOCK Wait 5 minutes after isolating supply before handling Failure to follow these instructions can result in injury or equipment damage 43
52 Low Voltage Capacitors VarPlus Box Energy Rated Voltage 380/400/415 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 380 V 400 V 415 V at 400 V 380 V 400 V 415 V at 400 V GB BLRBE125A150B GB BLRBE150A180B GB BLRBE167A200B GB BLRBE208A250B GB BLRBE250A300B IB BLRBE417A500B IB BLRBE500A600B40 Rated Voltage 480 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 400 V 415 V 480 V at 480 V 400 V 415 V 480 V at 480 V FB BLRBE125A150B FB BLRBE136A163B GB BLRBE155A186B GB BLRBE170A204B GB BLRBE208A250B IB BLRBE258A310B IB BLRBE288A346B IB BLRBE315A378B IB BLRBE339A407B IB BLRBE417A500B48 Rated Voltage 525 V 50 Hz 60 Hz µf (X3) Case Code Reference Number Q N (kvar) I N (A) Q N (kvar) I N (A) 415 V 480 V 525 V at 525 V 415 V 480 V 525 V at 525 V DB BLRBE100A120B FB BLRBE125A150B GB BLRBE250A300B IB BLRBE500A600B52 44
53 VarPlus Box Energy Harmonic applications VarPlus Box Energy capacitors with detuned reactors are designed to operate in harsh environments. Operating conditions For networks with a large number of non-linear loads (N LL < 50 %). Significant voltage disturbances. Severe temperature conditions up to 70 C. Very frequent switching operations up to 10,000/year. PE90154+PE90134_r.eps Rated voltage In a detuned filter application, the voltage across the capacitors is higher than the network service voltage (U S ). Then, capacitors must be designed to withstand higher voltages. + Detuned reactor VarPlusBox Energy Depending on the selected tuning frequency, part of the harmonic currents is absorbed by the detuned capacitor bank. Then, capacitors must be designed to withstand higher currents, combining fundamental and harmonic currents. The rated voltage of VarPlusBox Energy capacitors is given in the table below, for different values of network service voltage and relative impedance. Capacitor Rated Voltage U N (V) Relative Impedance (%) Network Service Voltage U S (V) 50 Hz 60 Hz In the following pages, the effective power (kvar) given in the tables is the reactive power provided by the combination of capacitors and reactors. 45
54 Low Voltage Capacitors VarPlus Box Energy + Detuned Reactor + Contactor + MCCB PE90154_L28_r.eps Network 400 V, 50 Hz Capacitor Voltage 480 V 5.7 % / 7 % Detuned Reactor Effective Q N Capacitor Ref. 5.7% fr = 210Hz 7% fr = 190Hz Switching: Protection: Power at Contactor Compact NSX (kvar) 480V D R Ref. D R Ref. Ref. (ICU=50kA) Ref BLRBE170A204B48 1 LVR05125A40T x 1 LVR07125A40T x 1 LC1D18 1 LV BLRBE339A407B48 1 LVR05250A40T x 1 LVR07250A40T x 1 LC1D32 1 LV BLRBE339A407B48 2 LVR05500A40T x 1 LVR07500A40T x 1 LC1D80 1 LV BLRBE339A407B48 4 LVR05X00A40T x 1 LVR07X00A40T x 1 LC1D150 1 LV PE90134_L28_r.eps + Network 400 V, 50 Hz Capacitor Voltage 480 V 14 % Detuned Reactor Effective Q N Capacitor Ref. 14% fr = 135Hz Switching: Protection: Power at Contactor Compact NSX (kvar) 480V D R Ref. Ref. (ICU=50kA) Ref BLRBE155A186B48 1 LVR14125A40T x 1 LC1D18 1 LV BLRBE315A378B48 1 LVR14250A40T x 1 LC1D32 1 LV BLRBE619A000B48 1 LVR14500A40T x 1 LC1D80 1 LV BLRBE619A000B48 2 LVR14X00A40T x 1 LC1D150 1 LV Network 400 V, 60 Hz Capacitor Voltage 480 V 5.7 % / 7 % Detuned Reactor Effective Q N Capacitor Ref. 5.7% fr = 250Hz 7% fr = 230Hz Switching: Protection: Power at Contactor Compact NSX (kvar) 480V D R Ref D R Ref Ref. (ICU=50kA) Ref BLRBE288A346B48 1 LVR05250B40T 1 LVR07250B40T 1 LC1D32 1 LV BLRBE288A346B48 2 LVR05500B40T 1 LVR07500B40T 1 LC1D80 1 LV BLRBE288A346B48 4 LVR05X00B40T 1 LVR07X00B40T 1 LC1D150 1 LV PE90158_L20_r copy.eps + Network 400 V, 60 Hz Capacitor Voltage 480 V 14 % Detuned Reactor Effective Q N Capacitor Ref. 14% fr = 160Hz Switching: Protection: Power at Contactor Compact NSX (kvar) 480V D R Ref. Ref. (ICU=50kA) Ref BLRBE258A310B48 1 LVR14250B40T 1 LC1D25 1 LV BLRBE516A619B48 1 LVR14500B40T 1 LC1D50 1 LV BLRBE516A619B48 2 LVR14X00B40T 1 LC1D150 1 LV PB eps 46
55 Box type capacitor Mechanical characteristics Case Code: AB - VarPlus Box Compact dimension Creepage distance 30 mm Clearance Phase to phase 25 mm (min.) Phase to earth 19 mm (min.) Mounting details: mounting screw M6, 2 Nos. Case code W1 W2 W3 H D Weight (kg) AB D DB eps Plastic Terminal cover H Enclosure W3 W2 W1 Plastic Terminal cover 192 Case Code: DB, EB, FB, GB & HB Creepage distance 30 mm Clearance Phase to phase 25 mm (min.) Phase to earth 19 mm (min.) Mounting details: mounting screw M6, 2 Nos. Case code W1 W2 W3 H D Weight (kg) DB EB FB GB HB D DB eps Rubber grommet for cable entry H Enclosure W3 W1 W2 47
56 Low Voltage Capacitors Box type capacitor Mechanical characteristics Case Code: IB Creepage distance 30 mm Clearance Phase to phase 25 mm (min.) Phase to earth 19 mm (min.) Mounting details: mounting screw M6, 2 Nos. Case code W1 W2 W3 H D Weight (kg) IB D DB eps Rubber grommet for cable entry H Enclosure W3 W1 W2 48
57 49
58 50
59 Detuned reactors Contents Presentation Power Factor Correction guideline 3 Low Voltage capacitors 15 Detuned reactors 51 Power Factor controllers 57 Contactors 61 Appendix 65 51
60 Detuned reactors Detuned reactors PE90154.eps The detuned reactors (DR) are designed to protect the capacitors by preventing amplification of the harmonics present on the network. Operating conditions Use: indoor. Storage temperature: -40 C, +60 C. Relative humidity in operation: %. Salt spray withstand: 250 hours (for 400 V - 50 Hz range). Operating temperature: altitude: 1000 m: Min = 0 C, Max = 55 C, highest average over 1 year = 40 C, 24 hours = 50 C. altitude: 2000 m: Min = 0 C, Max = 50 C, highest average over 1 year = 35 C, 24 hours = 45 C. Installation guidelines Forced ventilation required. Vertical detuned reactor winding for better heat dissipation. As the detuned reactor is provided with thermal protection, the normally closed dry contact must be used to disconnect the step in the event of overheating. Technical specifications General characteristics Description Degree of protection Insulation class Rated voltage Three-phase, dry, magnetic circuit, impregnated IP00 H 400 to 690 V - 50 Hz 400 to 600 V - 60 Hz Other voltages on request Inductance tolerance per phase -5, +5 % Insulation level 1.1 kv Dielectric test 50/60 Hz between 4 kv, 1 min windings and windings/earth Thermal protection Restored on terminal block 250 V AC, 2 A Let s define the service current (I S ) as the current absorbed by the capacitor and detuned reactor assembly, when a purely sinusoidal voltage is applied, equal to the network service voltage (V). I S = Q (kvar) / ( 3 x U S ) H W1 D1 W D For dimensions and more details, please consult us. In order to operate safely in real conditions, a detuned reactor must be designed to accept a maximum permanent current (I MP ) taking account of harmonic currents and voltage fluctuations. The following table gives the typical percentage of harmonic currents considered for the different tuning orders. (%) Harmonic currents Tuning order i 3 i 5 i 7 i 11 / Relative Impedance 2.7 / 14% / 7% / 5.7% Detuned reactor has to be protectced from over currents with MCCB. A 1.1 factor is applied in order to allow long-term operation at a supply voltage up to (1.1 x U S ). The maximum perment current (I MP ) is given in the following table: Tuning order I MP (times I S ) 2.7 / 14% / 7% / 5.7%
61 50 Hz Detuned reactors Network voltage 400 V, 50 Hz 50 Hz Relative Impedance (%) kvar Inductance (mh) I MP (A) Max losses at I MP (W) W W1 D D1 H Weight (kg) 5.70% LVR05065A40T (4.2) LVR05125A40T LVR05250A40T LVR05500A40T LVR05X00A40T 7% LVR07065A40T (3.8) LVR07125A40T LVR07250A40T LVR07500A40T LVR07X00A40T 14% LVR14065A40T (2.7) LVR14125A40T LVR14250A40T LVR14500A40T LVR14X00A40T Reference Number Network voltage 690 V, 50 Hz Relative Impedance (%) kvar Inductance (mh) I MP (A) Max losses at I MP (W) W W1 D D1 H Weight (kg) 5.70% LVR05125A69T (4.2) LVR05250A69T LVR05500A69T LVR05X00A69T 7% LVR07125A69T (3.8) LVR07250A69T LVR07500A69T LVR07X00A69T Reference Number Network voltage 230 V, 50 Hz Relative Impedance (%) kvar Inductance (mh) I MP (A) Max losses at I MP (W) W W1 D D1 H Weight (kg) 5.70% LVR05065A23T (4.2) LVR05125A23T LVR05250A23T Reference Number 53
62 60 Hz Detuned reactors Network voltage 400 V, 60 Hz 60 Hz Relative Impedance (%) kvar Inductance (mh) I MP (A) Max losses at I MP (W) W W1 D D1 H Weight (kg) 5.70% LVR05125B40T (4.2) LVR05250B40T LVR05500B40T LVR05X00B40T 7% LVR07125B40T (3.8) LVR07250B40T LVR07500B40T LVR07X00B40T 14% LVR14125B40T (2.7) LVR14250B40T LVR14500B40T LVR14X00B40T Reference Number Network voltage 480 V, 60 Hz 5.70% LVR05125B48T (4.2) LVR05250B48T LVR05500B48T LVR05X00B48T LVR05X00B48T LVR05X00B48T Network voltage 220 V, 60 Hz 5.70% LVR05125B22T (4.2) LVR05250B22T LVR05500B22T LVR05X00B22T Network voltage 240 V, 60 Hz 5.70% LVR05125B24T (4.2) LVR05250B24T LVR05500B24T Network voltage 600 V, 60 Hz 5.70% LVR05125B60T (4.2) LVR05250B60T LVR05500B60T LVR05750B60T LVR05X00B60T LVR05X50B60T 54
63 55
64 56
65 Power Factor controllers Contents Presentation Power Factor Correction guideline 3 Low Voltage capacitors 15 Detuned reactors 51 Varlogic series 57 NR6/NR12, NRC12 57 Contactors 61 Appendix 65 57
66 Power Factor controllers Varlogic series RT6, NR6/NR12, NRC12 PE90155.eps PE90161.eps The Varlogic controllers permanently monitor the reactive power of the installation and control the connection and disconnection of capacitor steps in order to obtain the targeted power factor. Varlogic RT6/8*/12* *: on request Performance Permanent monitoring of the network and equipment. Information provided about equipment status. Alarm signals transmitted in case of anomaly (for NR6, NR12, NRC12). Communication by Modbus protocol (for NRC12). New control algorithm designed to reduce the number of switching operations and quickly attain the targeted power factor. Simplicity Simplified programming and possibility of intelligent self set-up. Ergonomic layout of control buttons. Quick and simple mounting and wiring. A special menu allows controller self-configuration. User-friendliness The large display allows: Direct viewing of installation electrical information and capacitor stage condition. Direct reading of set-up configuration. Intuitive browsing in the various menus (indication, commissioning, configuration). Alarm indication. Monitoring and protection Alarms Should an anomaly occur on the network or the capacitor bank, alarms are indicated on the screen and alarm contact closure is initiated. The alarm message is maintained on the screen once the fault clears until it is manually removed. Protection If necessary, the capacitor steps are automatically disconnected to protect the equipment. PE90156.eps Varlogic NR6/12 Range Type Number of step output contacts Part number NR NR NRC RT RT RT Accessories Communication RS485 Modbus set for NRC Temperature external probe for NRC12 type in addition to internal probe allows measurement at the hottest point inside the capacitor bank Varlogic NRC12 58
67 Technical specifications General characteristics Output relays AC 5 A / 120 V 2 A / 250 V 1 A / 400 V DC 0.3 A / 110 V 0.6 A / 60 V 2 A / 24 V Protection Index Front panel IP41 Rear IP20 Measuring current 0 to 5 A Specific features RT6 NR-6/12 NRC12 Number of steps 6 6 / Supply voltage (V AC) 88 to to / 60 Hz 185 to to to to to to 460 Display 4 digit 7 segment LEDs 65 x 21 mm backlit screen 55 x 28 mm backlit screen Dimensions 143 x 143 x x 158 x x 158 x 80 Flush panel mounting 35 mm DIN rail mounting (EN 50022) Operating temperature 0 C 55 C 0 C 60 C 0 C 60 C Alarm contact Internal temperature probe Separate fan relay contact Alarm history Last 5 alarms Last 5 alarms Type of connection Phase-to-neutral Phase-to-phase Current input CT 10000/5 A CT 25/5 A 6000/5 A CT 25/1 A 6000/5 A Target cosϕ setting 0.85 ind ind. 0.9 cap. Possibility of a dual cosϕ target Accuracy ±2 % ±5 % ±2 % Response delay time 10 to 1800 s 10 to 120 s 10 to 180 s Reconnection delay time 10 to 1800 s 10 to 600 s 10 to 900 s 4-quadrant operation for generator application Communication protocol Modbus 59
68 60
69 Contactors Contents Presentation Power Factor Correction guideline 3 Low Voltage capacitors 15 Detuned reactors 51 Power Factor controllers 57 Contactors 61 Appendix 65 61
70 Contactors TeSys contactors For switching 3-phase capacitor banks, used for power factor correction Direct connection without choke inductors Special contactors LC1 D K are designed for switching 3-phase, single- or multiplestep capacitor banks. They comply with standards IEC and 60831, NFC , VDE 0560, UL and CSA. Special contactors Special contactors LC1 D K are designed for switching 3-phase, single or multiple-step capacitor banks (up to 6 steps). Over 6 steps, it is recommanded to use chokes in order to limit the inrush current and thus improve the lifetime of the installation. The contactors are conform to standards IEC and 60831, UL and CSA. PF eps Contactor applications Specification Contactors fitted with a block of early make poles and damping resistors, limiting the value of the current on closing to 60 In max. This current limitation increases the life of all the components of the installation, in particular that of the fuses and capacitors. The patented design of the add-on block (n ) ensures safety and long life of the installation. Operating conditions There is no need to use choke inductors for either single or multiple-step capacitor banks. Short-circuit protection must be provided by gi type fuses rated at In. Maximum operational power The power values given in the selection table below are for the following operating conditions: Prospective peak current LC1 D K 200 In at switch-on Maximum operating rate LC1 DFK, DGK, DLK, DMK, DPK 240 operating cycles/hour LC1 DTK, DWK 100 operating cycles/hour Electrical durability at nominal load All contactor ratings 400 V operating cycles 690 V operating cycles PF eps LC1 DFK11 Operational power at 50/60 Hz (1) q 55 C (2) Instantaneous auxiliary contacts Tightening torque on cable end Basic reference, to be completed by adding the voltage code (3) Weight 220 V 400 V 660 V 240 V 440 V 690 V kvar kvar kvar N/O N/C N.m kg LC1 DFK LC1 DGK LC1 DLK LC1 DMK LC1 DPK LC1 DTK LC1 DWK LC1 DPK12 Switching of multiple-step capacitor banks (with equal or different power ratings) The correct contactor for each step is selected from the above table, according to the power rating of the step to be switched. Example: 50 kvar 3-step capacitor bank. Temperature: 50 C and U = 400 V or 440 V. One 25 kvar step: contactor LC1 DMK, one 15 kvar step: contactor LC1 DGK, and one 10 kvar step: contactor LC1 DFK. (1) Operational power of the contactor according to the scheme on the page opposite. (2) The average temperature over a 24-hour period, in accordance with standards IEC and is 45 C. (3) Standard control circuit voltages (the delivery time is variable, please consult your Regional Sales Office): Volts /60 Hz B7 E7 G7 M7 P7 U7 Q7 V7 N7 R7 62
71 TeSys contactors For switching 3-phase capacitor banks, used for power factor correction Dimensions LC1 DFK, DGK LC1 DLK, DMK DB402404R.eps DB402405R.eps LC1 DPK, DTK LC1 DWK DB eps DB eps Schemes LC1 D K DB eps A1 13 NO 21 NC 1/L1 3/L2 5/L3 - R 31 NC A /T1 4/T2 6/T3 - R 32 R = Pre-wired resistor connections. 63
72 64
73 Appendix Contents Presentation Power Factor Correction guideline 3 Low Voltage capacitors 15 Detuned reactors 51 Power Factor controllers 57 Contactors 61 Influence of harmonics in electrical installations 66 Safety features 67 Protection Devices in APFC Panel 68 Find more about Power Quality Solutions 69 Glossary 70 Relevant documents 70 65
74 Appendix Influence of harmonics in electrical installations + Since the harmonics are caused by nonlinear loads, an indicator for the magnitude of harmonics is the ratio of the total power of nonlinear loads to the power supply transformer rating. This ratio is denoted N LL, and is also known as G h /S n : N LL = Total power of non-linear loads (G h )/ Installed transformer rating (S n ) Example: > Power supply transformer rating: S n = 630 kva > Total power of non-linear loads: G h = 150 kva > N LL = (150/630) x 100 = 24 %. Definition of harmonics The presence of harmonics in electrical systems means that current and voltage are distorted and deviate from sinusoidal waveforms. Harmonic currents are currents circulating in the networks and whose frequency is an integer multiple of the supply frequency. Harmonic currents are caused by non-linear loads connected to the distribution system. A load is said to be non-linear when the current it draws does not have the same waveform as the supply voltage. The flow of harmonic currents through system impedances in turn creates voltage harmonics, which distort the supply voltage. The most common non-linear loads generating harmonic currents use power electronics, such as variable speed drives, rectifiers, inverters, etc. Loads such as saturable reactors, welding equipment, and arc furnaces also generate harmonics. Other loads such as inductors, resistors and capacitors are linear loads and do not generate harmonics. Effects of harmonics Capacitors are particularly sensitive to harmonic currents since their impedance decreases proportionally to the order of the existing harmonics. This can result in capacitor overload, constantly shortening its operating life. In some extreme situations, resonance can occur, resulting in an amplification of harmonic currents and a very high voltage distortion. To ensure good and proper operation of the electrical installation, the harmonic level must be taken into account in selecting power factor correction equipment. A significant parameter is the cumulated power of the non-linear loads generating harmonic currents. Taking account of harmonics The percentage of non-linear loads N LL is a first indicator for the magnitude of harmonics. The proposed selection of capacitors depending on the value of N LL is given in the diagram below. N LL (%) EasyCan VarPlus (Can & Box) VarPlus Box Energy Capacitor with detuned reactor DE90182 Supply transformer Measure THDi, THDu A more detailed estimation of the magnitude of harmonics can be made with measurements. Significant indicators are current harmonic distortion THDi and voltage harmonic distortion THDu, measured at the transformer secondary, with no capacitors connected. According to the measured distortion, different technologies of capacitors shall be selected: Linear loads Non-linear loads THDi (%) EasyCan VarPlus (Can & Box) VarPlus Box Energy Capacitor with detuned reactor THDu (%) EasyCan VarPlus (Can & Box) VarPlus Box Energy Capacitor with detuned reactor The capacitor technology has to be selected according to the most restrictive measurement. Example, a measurement is giving the following results : - THDi = 15 % Harmonic solution. - THDu = 3.5 % VarPlus solution. Harmonic solution has to be selected. 66
75 Safety features DE90175 (a) (b) Self-healing is a process by which the capacitor restores itself in the event of a fault in the dielectric which can happen during high overloads, voltage transients etc. Figure 1 - (a) Metal layer - (b) Polypropylene film. When insulation breaks down, a short duration arc is formed (figure 1). DE90174 Figure 2 The intense heat generated by this arc causes the metallization in the vicinity of the arc to vaporise (figure 2). Simultaneously it re-insulates the electrodes and maintains the operation and integrity of the capacitor (figure 3). DE90173 Figure 3 DB T Pressure Sensitive Disconnector (also called tear-off fuse ): this is provided in each phase of the capacitor and enables safe disconnection and electrical isolation at the end of the life of the capacitor. Malfunction will cause rising pressure inside the can. Pressure can only lead to vertical expansion by bending lid outwards. Connecting wires break at intended spots. Capacitor is disconnected irreversibly. DB T+12+2 Cross-section view of a three-phase capacitor after Pressure Sensitive Device operated: bended lid and disconnected wires. 67
76 Appendix Protection Devices in APFC Panel Over voltage In the event of an over voltage, electrical stress on the capacitor dielectric and the current drawn by the capacitors will increase. The APFC equipment must be switched off in the event of over voltage with suitable over voltage relay / surge suppressor. Over Current Over current condition is harmful to all current carrying components. The capacitor bank components must be rated based on the maximum current capacity. A suitable over current relay with an alarm function must be used for over current protection. Short circuit protection Short circuit protection at the incomer of the capacitor bank must be provided by devices such as MCCB's and ACB's. It is recommended to use MCB or MCCB for short circuit protection at every step. Thermal Overload A thermal overload relay must be used for over load protection and must be set at 1.3 times the rated current of capacitors (as per IEC 60831). In case of de tuned capacitor banks, the over load setting is determined by the maximum over load capacity of the de tuning reactor. (1.12 = 4.2(14%), 1.19 = 3.8(7%), 1.3 = 2.7(5.7%)). If MCCB's are not present, it is recommended to use a thermal overload relay with the stage contactor to make sure the stage current does not exceed its rated capacity. Over Temperature protection The APFC controller must be tripped with the help of thermostats in cases the internal ambient temperature of the capacitor bank exceeds the temperature withstand characteristics of the capacitor bank components. Reactors are provided with thermal switches and can be isolated in the case of over temperature conditions. 68
77 Find more about Power Quality Solutions We deliver smart & cost-effective Power quality solutions to improve our customers efficiency VarSet Low Voltage Capacitor Banks Energy efficiency, as simple as VarSet Find out more visit and download PFCED310004EN AccuSine Harmonic Filtering and Reactive Power Compensations The Schneider Electric solution for active harmonic filtering in industrial and building installations Find out more visit and download AMTED109015EN Medium Voltage Power Quality Solutions Medium Voltage power factor and harmonic filtering solutions Find out more visit and download CFIED205098EN 69
78 Appendix Glossary Active current (Ia): In the vector representation, component of the current vector which is co-linear with the voltage vector. Active power: Real power transmitted to loads such as motors, lamps, heaters, computers, and transformed into mechanical power, heat or light. Apparent power: In a circuit where the applied r.m.s. voltage is Vrms and the circulating r.m.s. current is Irms, the apparent power S (kva) is the product: V rms x I rms. The apparent power is the basis for electrical equipment rating. Detuned reactor: Reactor associated to a capacitor for Power Factor Correction in systems with significant non-linear loads, generating harmonics. Capacitor and reactor are configured in a series resonant circuit, tuned so that the series resonant frequency is below the lowest harmonic frequency present in the system. Displacement Power Factor: For sinusoidal voltage and current with a phase angle j, the Power Factor is equal to cosj, called Displacement Power Factor (DPF) Harmonic distortion: Indicator of the current or voltage distortion, compared to a sinusoidal waveform. Harmonics: The presence of harmonics in electrical systems means that current and voltage are distorted and deviate from sinusoidal waveforms. Harmonic currents and voltages are signals circulating in the networks and which frequency is an integer multiple of the supply frequency. IEC : "Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including V Part 1: General Performance, testing and rating Safety requirements Guide for installation and operation". In-rush current: High-intensity current circulating in one piece of equipment after connection to the supply network. kva demand: Maximum apparent power to be delivered by the Utility, which determines the rating of the supply network and the tariff of subscription. Polypropylene: Plastic dielectric material used for the construction of low-voltage capacitors. Power Factor: The power factor is the ratio of the active power P (kw) to the apparent power S (kva) for a given circuit. = P (kw) / S (kva). Power Factor Correction: Improvement of the Power Factor, by compensation of reactive energy or harmonic mitigation (reduction of the apparent power S, for a given active power P). Rated current: Current absorbed by one piece of equipment when supplied at the rated voltage. Rated voltage: Operating voltage for which a piece of equipment has been designed, and which can be applied continuously. Reactive current (Ir): Component of the current vector which is in quadrature with the voltage vector. Reactive power: Product of the reactive current times the voltage. Service voltage: Value of the supply network voltage, declared by the Utility Service current: Amplitude of the steady-state current absorbed by one piece of equipment, when supplied by the Service Voltage. Usual formulas: Apparent power: S = V rms x l rms (kva). Active power: P = V rms x la = V rms x l rms x cosj (kw). Reactive power: Q = V rms x lr = V rms x l rms x sinj (kvar). Voltage sag: Temporary reduction of the supply voltage magnitude, between 90 and 1 % of the service voltage, with a duration between ½ period and Relevant documents Relevant documents published by Schneider Electric Electrical Installation Guide. Expert Guide n 4: "Harmonic detection & filtering". Expert Guide n 6: "Power Factor Correction and Harmonic Filtering Guide" Technical Guide 152: "Harmonic disturbances in networks, and their treatment". White paper: controlling the impact of Power Factor and Harmonics on Energy Efficiency. Relevant websites Relevant standards IEC Shunt power capacitors of the self healing for a.c. systems up to 1000V IEC Application of filters and shunt capacitors for industrial a.c. networks affected by harmonics IEC Power capacitors-low voltage power factor correction capacitor banks 70
79
80 Schneider Electric Industries SAS 35, rue Joseph Monier CS Rueil Malmaison Cedex France RCS Nanterre Capital social As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. This document has been printed on ecological paper Design: Schneider Electric Photos: Schneider Electric Edition: Altavia Connexion - made in France PEFC/ ART.xxxxxx Schneider Electric - All rights reserved. PFCED310003EN
Guide for the Design and Production of LV Power Factor Correction Cubicles
Power Factor Correction Guide for the Design and Production of LV Power Factor Correction Cubicles Panel Builder Guide 2011 Panel Builder Guide 2011 Contents CHAPTER 1: General design rules 3-11 Applicable
7. Reactive energy compensation
593 7. Reactive energy compensation 594 7. REACTIVE ENERGY COMPENSATION Reactive energy compensation is an important element for reducing the electricity bill and improving the quality of the electrical
Power factor correction and harmonic filtering. Rectimat 2 Automatic capacitor banks. Catalogue. Building a New Electric World
Catalogue 2002 Automatic capacitor banks Building a New Electric World 0Contents Power factor correction 2 Power factor equipment selection guide 3 General technical data 4 Capacitors and banks 50 z 6
MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS
MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS Meher Capacitors offers reliable and innovative products and solutions in the fields of Reactive Power Compensation, Power Quality and Energy
How To Build A Low Voltage Capacitor Lvcp
Low Voltage Capacitor LVCP The new choice for Power Factor Correction LVCP : the new choice for Power Factor Correction The LVCP is a compact and powerful capacitor. It offers high modularity, unmatched
Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE
Understanding Power Factor and How it Affects Your Electric Bill Presented by Scott Peele PE Understanding Power Factor Definitions kva, kvar, kw, Apparent Power vs. True Power Calculations Measurements
Chapter L Power factor correction and harmonic filtering
Chapter L Power factor correction and 1 2 3 4 5 6 7 8 9 10 Contents Reactive energy and power factor 1.1 The nature of reactive energy L2 1.2 Equipment and appliances requiring reactive energy L2 1.3 The
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
Product Data Bulletin
Product Data Bulletin Power System Harmonics Causes and Effects of Variable Frequency Drives Relative to the IEEE 519-1992 Standard Raleigh, NC, U.S.A. INTRODUCTION This document describes power system
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 READ CAREFULLY These instructions are intended to cover good practices in
HARMONIC DISTORTION IN THE ELECTRIC SUPPLY SYSTEM
Technical Note No.3 March 2000 HARMONIC DISTORTION IN THE ELECTRIC SUPPLY SYSTEM This Technical Note discusses harmonic distortion, its causes and adverse effects, what levels are unacceptable and how
EXTENDING THE LIFE OF POWER FACTOR CAPACITORS
by John Houdek, President, Allied Industrial Marketing, Inc., and Cesar Chavez, Engineering Manager, ARTECHE / Inelap Abstract: The addition of power factor improvement capacitors to individual motors
CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)
CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR) Fig1. CPTR SMART CONTROL PRECISION CUSTOMIZED MANUAL OR AUTO SCR OR DIODE DRY TYPE SWITCH MODE DRY TYPE SCR OR DIODE OIL TYPE 1 INDEX PAGE 1. Cover 2. Index
DYNACOMP The top-class dynamic response compensator
DYNACOMP The top-class dynamic response compensator Reactive power and Power Quality Reactive power Excessive reactive power drawn by linear- and non-linear loads deteriorates the Power Quality of the
SURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
POWER FACTOR CORRECTION
[CATALOGUE PFC-SFC] POWER FACTOR CORRECTION INDUSTRIAL SWITCHGEAR & AUTOMATION SPECIALISTS A component of nhp s green star solution... www.nhp.com.au Power Factor - What does it mean? Where open electricity
Specification guide no. 9 Active harmonic conditioner from 20 to 480 A
Active harmonic conditioner from 20 to 480 A Contents 1 - Installations concerned... 2 1.1 - New installations... 2 1.2 - Existing installations... 2 2 - General... 2 2.1 - Scope... 2 2.2 - Applicable
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Power Factor Correction for Power Systems First Semester Report Spring Semester 2007
Power Factor Correction for Power Systems First Semester Report Spring Semester 2007 by Pamela Ackerman Prepared to partially fulfill the requirements for EE401 Department of Electrical and Computer Engineering
How To Understand The Electrical Power Supply Of A Power Supply System
17 Circuit diagram symbols E 18 CIRCUIT DIAGRAM SYMBOLS electrical network elements three-phase line or cable single-phase line or cable short circuit earth electrode outgoing feeder supply incoming feeder
EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT
EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT 4 Understand single-phase alternating current (ac) theory Single phase AC
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Improvements of Reliability of Micro Hydro Power Plants in Sri Lanka
Improvements of Reliability of Micro Hydro Power Plants in Sri Lanka S S B Udugampala, V Vijayarajah, N T L W Vithanawasam, W M S C Weerasinghe, Supervised by: Eng J Karunanayake, Dr. K T M U Hemapala
max 6f / computer max
POWER FACTOR REGULATORS computer max max 6f / computer max max 12f Instructions Manual ( M98234601-03-10A ) - 1 - Index 1 INTRODUCTION AND SAFETY RECOMMENDATIONS... 3 1.1 DELIVERY SPOT CHECK... 3 1.2 STARTING
7-41 POWER FACTOR CORRECTION
POWER FTOR CORRECTION INTRODUCTION Modern electronic equipment can create noise that will cause problems with other equipment on the same supply system. To reduce system disturbances it is therefore essential
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
Specifying a Variable Frequency Drive s
Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable
21 st Century Facilities
Electrical Testing 21 st Century Facilities Facility Owners face tough challenges 24 X 7 reliability needed Non linear loads cause harmonics VFD Computers Switching transients disrupt operations Less customer
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission
Power transformers Generator step-up and system intertie power transformers Securing high-quality AC transmission Generator step-up transformers Built to withstand continuous full load Generator step-up
FACTS. Solutions to optimise network performance GRID
Solutions to optimise network performance GRID Solutions to optimise your network Our worldwide presence: Better solutions for your network all around the world Tampere Philadelphia Stafford Konstanz Beijing
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A
AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
Harmonic components: electrical network polluters. LV and MV networks are becoming increasingly polluted by current and voltage harmonics. Harmonics a
Harmonics and transformers Harmonic component filter Harmonic components: electrical network polluters. LV and MV networks are becoming increasingly polluted by current and voltage harmonics. Harmonics
Permissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
SURVEY OF HARMONIC DISTORTION IN LV AND MV NETWORKS: RESULTS AND CORRECTIVE STRATEGIES
SURVEY OF HARMONIC DISTORTION IN LV AND MV NETWORKS: RESULTS AND CORRECTIVE STRATEGIES E Bompard*, E Carpaneto*, R Napoli*, P Ribaldone**, C Vercellino** * Dipartimento di Ingegneria Elettrica Industriale,
Line Reactors and AC Drives
Line Reactors and AC Drives Rockwell Automation Mequon Wisconsin Quite often, line and load reactors are installed on AC drives without a solid understanding of why or what the positive and negative consequences
Securing your electrical installations Prisma,
Securing your electrical installations Prisma, an optimised solution for type tested low voltage switchboards up to 3200 A Table of contents Developing installation safety 4 Prisma P * Electrical switchboards
Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
Guidelines on the Short Circuit Current Rating for Industrial Control Panels
usa.siemens.com/sccr Guidelines on the Short Circuit Current Rating for Industrial Control Panels Technical Paper for Practical Applications White Paper I October 2014 As per NEC Edition 2014, and UL508A
Capacitors for A.C. motor applications
Capacitors for A.C. motor applications Contents Page General information 2 to 7 Capacitor selection guide 8 to 10 Plastic case series 11 to 37 Metalcaseseries 39to52 Boxseries 53to56 Mechanical drawings
Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
Presentation of the France Transfo factories
Presentation of the France Transfo factories France Transfo's internationally recognised and highly esteemed expertise is today exported to more than 80 countries throughout the world. Over the past 15
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011
, 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially
Table of Contents. TransformerIQ FAQs 1
[12/12] FAQs Table of Contents FAQ 1. What size transformer will TransformerIQ monitor?... 2 FAQ 2. Are there different TransformerIQ versions?... 2 FAQ 3. How are the units powered?... 2 FAQ 4. What is
Low Voltage Products
Low Voltage Products ABB Power Quality Filters: The most efficient solution for active filtering of harmonics, smooth reactive power compensation and load balancing. Enabling trouble-free and efficient
Low Voltage Products. Low Voltage Capacitor Banks Power Factor Correction Solutions
Low Voltage Products Low Voltage Capacitor Banks Power Factor Correction Solutions ABB LV Capacitor Banks The Most Comprehensive Solution for Automatic Power Factor Correction 2 ABB LV Capacitor Banks
Harmonics in your electrical system
Harmonics in your electrical system What they are, how they can be harmful, and what to do about them Abstract Harmonic currents, generated by non-linear electronic loads, increase power system heat losses
How To Choose A Transformer
Consider open loop MV network as an example source 1 source 2 NC NC NC or NO main MV switchboard A B Detail design of substation NC NC NC NO NC NC switchboard 1 switchboard 2 switchboard 3 MV MV MV LV
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
The Quest for Energy Efficiency. A White Paper from the experts in Business-Critical Continuity
The Quest for Energy Efficiency A White Paper from the experts in Business-Critical Continuity Abstract One of the most widely discussed issues throughout the world today is the rapidly increasing price
Power Quality Issues, Impacts, and Mitigation for Industrial Customers
Power Quality Issues, Impacts, and Mitigation for Industrial Customers By Kevin Olikara, Power and Energy Management Products Rockwell Automation, Inc. Now, more than ever, electronic equipment and computing
Three phase circuits
Three phase circuits THREE PHASE CIRCUITS THREE-PHASE ADVANTAGES 1. The horsepower rating of three-phase motors and the kva rating of three-phase transformers are 150% greater than single-phase motors
However, industrial applications may utilize a relay, which short-circuits the ICL path after the inrush sequence.
Application note for Inrush Current Limiters (ICL) Turning on electrical devices generally cause high inrush currents which can damage electronic components and cause interruption of the line voltage if
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
GUIDE FOR TESTING POWER TRANSFORMERS
GUIDE FOR TESTING POWER TRANSFORMERS Routine test 11/11/02 Pagina 1 di 10 INDEX Introduction... 3 1 Dielectric tests Separate-source voltage withstand test... 4 2 Induced voltage test... 5 3 Voltage ratio
ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.
POWER SUPPLY SYSTEMS AND ELECTRICAL EQUIPMENT FOR DESALINATION PLANTS Y.M. Hamud and A.H. Anwar Abu Dhabi Water and Electricity Authority, Abu Dhabi, UAE Keywords : Electrical System, Network for Desalination,
Energy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
The Facts About Harmonics and Power Factor. Power Quality: Harmonics & Power Factor Correction
The Facts About Harmonics and Power Factor Power Quality: Harmonics & Power Factor Correction 1 Agenda I. Harmonic Basics II. Harmonic Mitigation Methods III. Active Harmonic Filters IV. Applications V.
RC NETWORKS SALES GUIDE
SALES GUIDE INTRODUCTION TO Recent developments in electronic equipment have shown the following trends: Increasing demands for numerical control machines, robotics and technically advanced appliances
Short Circuit Current Calculations
Introduction Several sections of the National Electrical Code relate to proper overcurrent protection. Safe and reliable application of overcurrent protective devices based on these sections mandate that
Fundamentals of Power
Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At
User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters
SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm
Low Voltage Products. Switches Automatic Transfer Switches
Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,
www.siemens.com/energy High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.
s www.siemens.com/energy High Voltage Circuit Breakers AP Type 7.5 kv to 800 kv Answers for energy. The AP High Voltage Circuit Breakers Available up to 800 kv Decades of our experience in high voltage
Introduction. Harmonics and IEEE 519 Page 1 of 19
Introduction In an ideal power system, the voltage supplied to customer equipment, and the resulting load current are perfect sine waves. In practice, however, conditions are never ideal, so these waveforms
Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation
Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation Index News Introduction Applications & Segments Main Components Applicable Standards Technical characteristics
Electrical Network Management System
Electrical Network Management System Optimisation of the electrical network Measure to understand Understand to control Control to optimise Cost of power and fluids Power quality Power availability 2 Improvement
Technical data UNIBLOCK UBSF 180 625
Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
Life Expectancy : Class A Class B Class C Class D 30,000hrs 10,000hrs 3,000hrs 1000hrs
3.2 Motor Run Capacitors : continuous operation ypical Applications : Motor Run Capacitor ideal for various motor applications in washing machine, air conditioner, electric water pump, power factor collection
PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions
PMCS Integrated Energy Management Solution Unlock the Full Potential of Power Networks Through Integration Power Management Control System (PMCS) is a highly customizable, fully integrated end-to-end Energy
Power Capacitor Units for improved power quality
Power Capacitor Units for improved power quality Applications for capacitors Reactive power compensation Most of the apparatus and loads connected to the electrical power system consume both active and
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
IRON-CORE REACTORS FOR DETUNING POWER CAPACITORS IN MEDIUM AND LOW VOLTAGE NETWORKS
IRON-CORE REACTORS FOR DETUNING POWER CAPACITORS IN MEDIUM AND LOW VOLTAGE NETWORKS ED DTR 06.11 Made in Germany H A N S V O N M A N G O L D T A A C H E N Harmonic network distortion and its effects (
3-PHASE LOW VOLTAGE NETWORK LOAD BALANCER : A COST EFFECTIVE SOLUTION TO LINE VOLTAGE VARIATIONS
3-PHASE LOW VOLTAGE NETWORK LOAD BALANCER : A COST EFFECTIVE SOLUTION TO LINE VOLTAGE VARIATIONS Pierre FRISTOT Olivier CONSTANT Catherine MONCET Omegawatt - France Omegawatt - France SDET - France [email protected]
MV POWER CAPACITORS AND BANKS. All film dielectric MV Power Capacitors QUALITY MADE IN ITALY
2014 MV POWER CAPACITORS AND BANKS BIORIPHASO TF All film dielectric MV Power Capacitors QUALITY MADE IN ITALY Index Icar: Products and solutions 1 ICAR Quality System 3 Medium and High Voltage Solutions
UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES
UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES WHITE PAPER: TW0062 36 Newburgh Road Hackettstown, NJ 07840 Feb 2009 Alan Gobbi About the Author Alan Gobbi Alan Gobbi
SIZING THE PRIMARY POWER SYSTEM FOR RESISTANCE WELDERS
SIZING THE PRIMARY POWER SYSTEM FOR RESISTANCE S By Jack Farrow, May, 2004 WELDING TECHNOLOGY CORPORATION ABSTRACT Information on how to select the correct size of substation transformer and 480V bus to
13. Electrical network design methodology and application example
873 13. Electrical network design methodology and application example 874 13. ELECTRICAL NETWORK DESIGN METHODOLOGY AND APPLICATION EXAMPLE The profitability of an industrial installation is directly linked
SUCCESS EPCOS Capacitors
SUCCESS EPCOS Inc. Capacitors Group April, 2012 EV / HV / E-Mobility Battery charger system & Inverter On Board and Off Board Assembly Trend: Wireless Charging DC/DC Converter Filtering DC Link E-Mobility
CAPACITOR AND APFC SYSTEM SERVICE MANUAL
CAPACITOR AND APFC SYSTEM INSTALLATION & TROUBLE SHOOTING 1. POWER FACTOR IS NOT IMPROVING 1. Please check if required kvar of capacitors are installed. 2. Check the type of capacitor installed is suitable
Power factor correction. An introduction to technology and techniques
Power factor correction An introduction to technology and techniques 2 Contents Understanding power factor 03 Power factor correction 05 Implementing power factor correction techniques 06 Glossary 07 Further
HOW HARMONICS HAVE CONTRIBUTED TO MANY POWER FACTOR MISCONCEPTIONS
White Paper: MIRUS-TP003-A January 15, 2014 HOW HARMONICS HAVE CONTRIBUTED TO MANY POWER FACTOR MISCONCEPTIONS Prepared by: Anthony (Tony) Hoevenaars, P. Eng President and CEO Mirus International Inc.
Variable Frequency Drives - a Comparison of VSI versus LCI Systems
Variable Frequency Drives - a Comparison of VSI versus LCI Systems Introduction TMEIC is a leader in the innovative design and manufacture of large ac variable f requency drive systems. TMEIC has been
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
CAPACITOR BANK TESTING SWP
1. PURPOSE AND SCOPE The purpose of this Standard Work Practice (SWP) is to standardise and prescribe the method for testing Capacitor Banks including capacitors, tuning reactors and inrush limiting reactors.
FAQs-Main switchboard design criteria
FAQs-Main switchboard design criteria Q: What is the Australian standard for main switchboards? Current Australian standard is AS/NZS 3439.1: 2002 originating from IEC 60439. The new series of standard
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches
LIMITING SHORT-CIRCUIT CURRENTS IN MEDIUM-VOLTAGE APPLICATIONS
LIMITING SHORT-CIRCUIT CURRENTS IN MEDIUM-VOLTAGE APPLICATIONS Terence Hazel Senior Member IEEE Schneider Electric 38050 Grenoble France Abstract The power requirements for large industrial sites is increasing.
IEC 61439-1 & 2 standard. The reference for safe and reliable LV switchboards
IEC 61439-1 & 2 standard The reference for safe and reliable LV switchboards IEC61439-1 & 2 The power of a standard adapted to your needs IEC standards are today legal or market references. The new IEC
Digital Energy ITI. Instrument Transformer Basic Technical Information and Application
g Digital Energy ITI Instrument Transformer Basic Technical Information and Application Table of Contents DEFINITIONS AND FUNCTIONS CONSTRUCTION FEATURES MAGNETIC CIRCUITS RATING AND RATIO CURRENT TRANSFORMER
Comparative study for cables and busbars
Comparative study for cables and busbars Preliminary considerations To compare the prices of two categories of product as different as traditional cables and busbars, it is necessary to make some preliminary
The design and performance of Static Var Compensators for particle accelerators
CERN-ACC-2015-0104 [email protected] The design and performance of Static Var Compensators for particle accelerators Karsten Kahle, Francisco R. Blánquez, Charles-Mathieu Genton CERN, Geneva, Switzerland,
Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components
Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components Course No: E02-010 Credit: 2 PDH Boris Shvartsberg, Ph.D., P.E., P.M.P. Continuing Education