1 Spare parts for: LAUNDRY EQUIPMENT - Contactors - Overload Cutout - Main panel boards - Activators - Actuators This catalogue is automatically generated. Therefore, the sequence of the items might not be always shown at best. Updates will be issued in case of additions and/or amendments. Rel Auxiliary contacts
2 CONTACTOR AEG LS07 16A 230V 50/60Hz 3Kw CONTACTOR AEG LS07 16A 230V 50/60Hz 3Kw ELETTROBAR CONTACTOR AEG LS07 16A 400V 50/60Hz 3Kw CONTACTOR AEG LS07 16A 400V 50/60Hz 3Kw coil 400V 50/60Hz coil 400V 50/60Hz CONTACTOR AEG LS07 16A 24V 50/60Hz 3Kw CONTACTOR AEG LS07 16A 24V 50/60Hz 3Kw coil 24V 50/60Hz coil 24V 50/60Hz HUDSON CONTACTOR AEG LS07 16A 230V 50/60Hz 3Kw CONTACTOR AEG LS4K 9A 400V 50/60Hz 4KW coil 400V 50/60Hz LAMBER CONTACTOR AEG LS4K 9A 400V 50/60Hz 4Kw AUXILIARY CONTACT AEG HS7K.01 coil 400V 50/60Hz pg. 2
3 CONTACTOR AEG LS4K 9A 24V 50/60Hz 4Kw AUXILIARY CONTACT AEG SH04.31 coil 24V 50/60Hz coil 16A 230V 50/60Hz THERMAL RELAY AEG B27T THERMAL RELAY AEG B27T A A A A A 4 6.3A A 8 12A pg. 3
4 AEG MOTOR OVERLOAD CUTOUT Mbs25 50/60Hz 10 16A 1.5Kw / 2.5 4A AEG MOTOR OVERLOAD CUTOUT Mbs25 50/60Hz CONTACTOR BENEDIKT/JAGER K2-12A10 3Kw / 4 6.3A coil 220/240V 50/60Hz 5.5Kw 4 normally open contacts for OVEN ZANUSSI FREQUENCY CONVERTER LS SV0004IC5-1F CONTACTOR MOD. A power contact 30A - 230V 4 Kw / 230 V - 7,5 Kw / 440 V WHIRLPOOL IMESA 2950CONEN CONTACTOR LOVATO BF1201A CONTACTOR 4S - MOD. TP3250 coil 12A 230V 50/60Hz 5.7Kw '16A 250V - 400V 3 normally closed contacts '50/60Hz ANGELO PO ANGELO PO 32Z2083 ICEMATIC CF ASKO ASKO IMESA ASK SCOTSMAN SCOTSMAN SIMAG PRIMUS PRIMUS WHIRLPOOL SIMAG SOCOLMATIC B3 ZANUSSI 0KD792 WHIRLPOOL WHIRLPOOL pg. 4
5 CONTACTOR AEG LS05 9A 230V 50/60Hz 4Kw AUXILIARY CONTACT AEG HS05.01 BARON A BARTSCHER BARTSCHER COLGED DTC112 COLGED REB DIHR 15086/B ELETTROBAR ELETTROBAR ELETTROBAR ELETTROBAR ELETTROBAR FRI FRI FRIMA GIGA D HOONVED KROMO 15086/B LAMBER OLIS A RANCILIO RATIONAL RATIONAL FRIMA RATIONAL AUXILIARY CONTACT AEG HS CONTACTOR AEG LS4K 9A 24V 50/60Hz 4Kw CONTACTOR AEG LS7K 18A 230V 50/60Hz 7.5Kw COMENDA COMENDA MARELS MODULAR coil 24V 50/60Hz BARON COMENDA EMMEPI C00571 GIGA X55300 KÜPPERSBUSCH MARENO CM MARENO PROJECT SYSTEMS RATIONAL SILKO MACM SILKO WHIRLPOOL WINTERHALTER ZANOLLI ELET0002 CONTACTOR AEG LS7K 18A 230V 50/60Hz 7.5Kw 4 normally open contacts AMBACH DESCO EBERHARDT FRIMA RATIONAL SILKO pg. 5
6 CONTACTOR AEG LS4K 9A 230V 50/60Hz 4Kw AUXILIARY CONTACT AEG HS7K.01 COMENDA ELFRAMO ELFRAMO ELFRAMO 628 ELFRAMO EMMEPI 8C0148 FAGOR RT FRIMA FRIMA GIORIK KOMEL KOMEL 628 KOMEL KOMEL OFFCAR FX RATIONAL RATIONAL RATIONAL REPAGAS WINTERHALTER CONTACTOR AEG LS7K 18A 230V 50/60Hz 7.5Kw ELFRAMO ELFRAMO FAGOR RT GIGA Y11100 KOMEL KOMEL KÜPPERSBUSCH RATIONAL RATIONAL WHIRLPOOL CONTACTOR AEG LS4K 9A 230V 50/60Hz 4Kw AUXILIARY CONTACT AEG HS7K.01 FAGOR RT FAGOR R FAGOR Z FRIMA FRIMA LAMBER RATIONAL RATIONAL CONTACTOR AEG LS11K 25A 230V 50/60Hz AUXILIARY CONTACT AEG HS Kw 6A BARTSCHER FAGOR R FAGOR X FRIMA FAGOR R FRI FRI RATIONAL RATIONAL pg. 6 FRIMA RATIONAL
7 TRAP CONTACT 5A 250V Crouzet for WASHING MACHINE DANUBE GF for WASHING MACHINE GRANDIMPIANTI WFEC for WASHING MACHINE IPSO HF-HC-HW DANUBE GRANDIMPIANTI IPSO 209/00255/00 CONTACTOR AEG LS15K 32A 230V 50/60Hz AUXILIARY CONTACT AEG HS7K.01 16Kw KÜPPERSBUSCH RATIONAL AUXILIARY CONTACT AEG SH CONTACTOR AEG LS07 16A 230V 50/60Hz 3Kw coil 16A 230V 50/60Hz 2 normally open contacts 2 normally open auxiliary contacts KÜPPERSBUSCH KÜPPERSBUSCH KÜPPERSBUSCH FAGOR Z TRAP CONTACT for DRYER MIELE T5205 for heating V-50Hz-7.5Kw MIELE WHIRLPOOL PRIMUS PRI WHIRLPOOL WHIRLPOOL WHIRLPOOL WHIRLPOOL CONTACTOR AEG LS05 9A 230V 50/60Hz 4Kw PRIMUS AUXILIARY CONTACT AEG HS05.01 FRIMA RATIONAL WINTERHALTER CONTACTOR MOD. LC1 D32 MIELE LAMBER FRIMA pg. 7 RATIONAL WHIRLPOOL
8 AUXILIARY CONTACT AEG HS CONTACTOR AEG LS22K 50A 230V 50/60Hz 30Kw RATIONAL FRIMA AEG MOTOR OVERLOAD CUTOUT Mbs25 50/60Hz RATIONAL AEG MOTOR OVERLOAD CUTOUT Mbs25 50/60Hz 0.55Kw / 1 1.6A 1.1Kw / A FRIMA CONTACTOR AEG LS30K 65A 230V 50/60Hz FRIMA Kw RATIONAL FRIMA PHASE CONTACTOR for motor 24V-2.2Kw PRIMUS RSPM RATIONAL CONTACTOR MCB-01 for emergency stop WHIRLPOOL WHIRLPOOL IMESA 2950PULEM494 pg. 8 WHIRLPOOL
9 The data herewith contained may change without notice and LF SpA cannot be held responsible for possible errors stated or resulting by the use of this document. All rights reserved. No part of this publication may be reproduced without written permission by LF SpA.
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
More informationERRE 2. Cooking equipment. Spare parts for: Suitable for:
Spare parts for: Cooking equipment This catalogue is automatically generated. Therefore, the sequence of the items might not be always shown at best. Updates will be issued in case of additions and/or
More informationMotors COFFEE MACHINES. Spare parts for: - Motor fans - Gear motor - Torque limit switch - Rotors - Motor carbons
Spare parts for: COFFEE MACHINES - Motor fans - Gear motor - Torque limit switch - Rotors - Motor carbons This catalogue is automatically generated. Therefore, the sequence of the items might not be always
More informationCIMBALI COFFEE GRINDERS. Spare parts for:
Spare parts for: COFFEE GRINDERS Important: this catalogue is automatically generated, therefore the sequence of the items might not be always shown at best updates will be issued in case of additions
More informationKRUPPS. Warewashing equipment. Spare parts for: Suitable for:
Spare parts for: Warewashing equipment 1 1 Rel. 013-09301649 his catalogue is automatically generated. herefore, the sequence of the items might not be always shown at best. Updates will be issued in case
More informationLabotek Reservedelside
Desiccant Flex Dryer Oversigt Go to R-026.01.A Hoved dele Go to R-026.02.A Hoved dele Go to R-026.03.A Blæser dele Go to R-026.04.A Blæser dele Go to R-026.05.A Maskin detaljer Go to R-026.06.A Maskin
More informationChapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams
Chapter 5 Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams Objectives Upon completion of this course, you will be able to: Explain what electrical loads are and their general purpose
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationBG or BGE Brake Rectifier
Brake Voltage Supplied from the otor There are specific instances when the brake voltage can be tapped from the motor's terminal block. The advantage of brake systems wi in this way is when power is applied
More informationElectrical Symbols and Line Diagrams
Electrical Symbols and Line Diagrams Chapter 3 Material taken from Chapter 3 of One-Line Diagrams One-line diagram a diagram that uses single lines and graphic symbols to indicate the path and components
More informationHow can a charging station for electric vehicles be set up simply and safely?
SB18 Building > Electromobility > Charging Station Design How can a charging station for electric vehicles be set up simply and safely? Requirement In order to supply electric vehicles with electric power,
More informationCool Design for Homes and Offices
AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive, and designed to fit any space: there are Cool Design for Homes and Offices a lot of reasons why Air Blue air conditioners
More informationTECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)
TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.) 1. Requirement: Two (02) Nos. DC Type, 3 phase, 3 wire Projection Welding Machine is required for welding of ventilation M.S. / Stainless
More information300 MY HOME Energy management
300 MY HOME COTETS. MY HOME oad control management General features. 302 General rules for installation. 308 Configuration 311 Wiring diagrams. 314 MY HOME 301 GEERA FEATURES The end of the black-out The
More informationTechnical catalogue. Modular DIN rail components Installation contactors
Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a
More informationABB central inverters PVS800 100 to 1000 kw
Solar inverters ABB central inverters PVS800 100 to 1000 kw ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators and
More informationProducts and solutions for lifting systems
Products and solutions for lifting systems 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters founded
More informationElectrical Charge: a type of energy that comes from the flow of charged particles; it allows electrical devices to function.
Unit E: Electrical Applications Chapter 11: Electrical Energy 11.1: Generating Electricity pg. 420 Key Concepts: 1. Electrical energy is generated using a variety of technologies. 2. Electrical energy
More informationwww.inspection-for-industry.com
Quality Control Form (TEST RUNNING RECORD FOR AIR HANDLING UNIT) SUB POWER SUPPLY: MAIN POWER V, Hz, CONTROL V, Blower 1 kw, Blower 2 kw, Compressor: (1) kw (2) kw (3) kw (4) kw Heating Element: kw 1.
More informationADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW
ADS8 IP54 Direct-On-Line Starter Technical Focus Replaces ADS7 Rated up to 9kW New ADS8 Motor Starter The new ADS8 range of motor starters replaces the successful ADS7 range which was introduced 20 years
More informationProgramming A PLC. Standard Instructions
Programming A PLC STEP 7-Micro/WIN32 is the program software used with the S7-2 PLC to create the PLC operating program. STEP 7 consists of a number of instructions that must be arranged in a logical order
More informationUniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution
UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,
More informationProgramming Logic controllers
Programming Logic controllers Programmable Logic Controller (PLC) is a microprocessor based system that uses programmable memory to store instructions and implement functions such as logic, sequencing,
More informationUS Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)
4 NC1 D09-D18 NC1 -D32 US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) Standards: UL508, CSA C22.2, IEC 60947, and CE Marked Integral DIN Rail & Base Mounting in One Compact
More informationMaximum Demand Control
Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility
More informationPanorama. Motor protection and control Manual motor starters, contactors and overload relays
Panorama Motor protection and control Manual motor starters, contactors and overload relays ABB sets a new standard in motor control and power switching Featuring AF technology as standard, the latest
More informationPSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
More informationALPENINOX. Cooking equipment. Spare parts for: Suitable for:
Spare parts for: Cooking equipment This catalogue is automatically generated. Therefore, the sequence of the items might not be always shown at best. Updates will be issued in case of additions and/or
More informationREVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)
SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY
More informationControls Solid-State Switching Devices
Controls Solid-State Switching Devices Introduction Overview 3RF21 3RF20 3RF23 3RF29 SIRIUS SC solid-state switching devices Solid-state relays 22.5 mm solid-state relays, 5 mm solid-state relays Solid-state
More informationMotor circuit-breakers
Thermal-magnetic motor circuit-breakers type GV2-M GV2-M Thermal-magnetic motor circuit-breakers GV2-M Pushbutton control Standard power ratings Setting Magnetic Thermal Reference Weight of 3-phase motors
More informationSIAPI srl Via Ferrovia Nord, 45 31020 S. Vendemiano Treviso - Italia T. +39 0438 4096 F. +39 0438 401016
1 1. MACHINE DESCRIPTION 1.1 General The SIAPI machine mod. EA1S produces PET bottles cavities by a stretch-blowing twostage process. It is intended for productions of containers with a capacity that ranges
More informationProducts and solutions for machine builders (OEM) 100% electricity
Products and solutions for machine builders (OEM) 100% electricity www.lovatoelectric.com Tra dition and innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters
More informationSERVICE MANUAL REFRIGERATION
SERVICE MANUAL REFRIGERATION ELECTROLUX HOME PRODUCTS S.p.A. Publication no. Spares Operations Italy 599 36 16-90 Corso Lino Zanussi, 30 031117 I - 33080 PORCIA / PN (ITALY) ITZ/SERVICE/AA Fax +39 0434
More informationElegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner
Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of
More informationProducts and solutions for pumping, irrigation and piping
Products and solutions for pumping, irrigation and piping 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric
More informationData Sheet. Electro-mechanical counters Hengstler 800 series
Data Pack D Issued March 00 504897 Data Sheet Electro-mechanical counters Hengstler 800 series The 800 series totalising and predetermining batch counters, manufactured by Hengstler, is available from
More informationTA-A BED TYPE MILLING CENTRE
TA-A BED TYPE MILLING CENTRE TA-A BED TYPE MILLING CENTRE MILLING CENTRE HIGH CAPACITY IN A COMPACT MACHINE High stock removal capacity TA-A BED TYPE MILLING CENTRE 2 TA-A The TA-A milling centre is a
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
More informationCHECK LIST OF SITE INSPECTION ON LV ELECTRICAL INSTALLATION (Basic Information to be filled by Consultant)
CHECK LIST OF SITE INSPECTION ON FORM EPS / E 5 PAGE 1 / 7 To : Head of District, SYABAS District Consultant : Name of Development : File No : Date : PUMP HOUSE 1.0 A. SQUIRREL CAGE MOTOR No. of Pump set
More informationCatalog. Modular DIN rail components Installation contactors
Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation
More informationTHERMOSTATS FOR WASHING AND CAPILLARIES / TERMOSTATI LAVAGGIO E SONDE
08AG003 08AG007 NA 40 C NA 60 C ORIG. CODE: 481981729131 ORIG. CODE: 005927 08AG016 08AG023 NC 40 C NC 80 C ORIG. CODE: 016543 ORIG. CODE: 015856 08AG038 08AG039 NA 40 C - NC 90 C NA 90 NA 40 E NA 90 NA
More informationCircuit Breakers. NRC Series. NRC Series. 900 www.idec.com
Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,
More informationEET272 Worksheet Week 8
EET272 Worksheet Week 8 answer questions 1-5 in preparation for discussion for the quiz on Monday. Finish the rest of the questions for discussion in class on Wednesday. Question 1 Questions We will now
More informationCPME75-100 CABLE PUSHING MACHINE WITH ELECTRIC MOTOR. fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES
CPME75-100 CABLE PUSHING MACHINE WITH ELECTRIC MOTOR fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES ABOUT US Our company ever since its incorporation in the telecommunication sector has been operating
More informationREGULINE 600VA / 1000VA REGULATOR USER MANUAL
REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate
More informationBETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
More informationLow Profile Unit Cooler
Super-Flo Now available with EC Motors High Efficiency / High Reliability Low Profile Unit Cooler Publication No. 411.4 November, 2008 S A N I T A T I O N F O U N D A T I O N A L N A T I O N Air Defrost
More informationSoftstarters. Type PST/PSTB Fieldbus communication CANopen for PST sw CU 06.00.00. 1SFC132070M0201 February 2011 1SFC132070M0201 1
Softstarters Type PST/PSTB Fieldbus communication CANopen for PST sw CU 06.00.00 1SFC132070M0201 February 2011 1SFC132070M0201 1 CANopen The CANopen protocol is a fieldbus protocol that provides full control
More informationMC Series Drives. Flexible, simple, rugged, robust! Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: info@actechdrives.
Drives Flexible, simple, rugged, robust! Our promise Commitment to Price Leadership Price leadership is serious business. It takes continuous life cycle management to make price leadership a sustainable
More informationwww.siemens.com/energy High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.
s www.siemens.com/energy High Voltage Circuit Breakers AP Type 7.5 kv to 800 kv Answers for energy. The AP High Voltage Circuit Breakers Available up to 800 kv Decades of our experience in high voltage
More informationREB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The
More informationCOUNTY OF LOS ANGELES BUILDING AND SAFETY DIVISION ELECTRICAL CODE FEE SCHEDULE (Title 27 of the County of Los Angeles Code, Ord No.
COUNTY OF LOS ANGELES BUILDING AND SAFETY DIVISION ELECTRICAL CODE FEE SCHEDULE (Title 27 of the County of Los Angeles Code, Ord No. 2013-0049) Effective July 1, 2014, Electrical Permit Fees in the unincorporated
More informationIn addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).
DS3002 1. General Description This data sheet describes the Modular Power (MP) Electro Hydraulic Power Units, which have been designed to provide an advanced and flexible means of brake control. The MP
More informationElectronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
More informationInstallation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201
Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC 10300 C001 ABB STOTZ-KONTAKT GmbH CDC 10300 C001 Low Voltage Products and Systems We ensure safety and comfort for
More informationWhite paper. ABB solutions for switching and protection of low speed wind turbines
White paper ABB solutions for switching and protection of low speed wind turbines ABB solutions for switching and protection of low speed wind turbines Index 1 Introduction...2 2 Full converter configuration...4
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationMAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R. www.heating.danfoss.com
MAKING MODERN LIVING POSSIBLE Wiring Diagram www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English
More informationkrones AirCo The air conveyor for PET bottles
The air conveyor for PET bottles The PET containers seem to be floating on air PET bottles should be treated gently. This is why the AirCo helps these sensitive lightweights float reliably and gently from
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationHigh-Voltage Circuit-Breakers 3AP1/2 72.5 kv up to 550 kv. Power Transmission and Distribution
High-Voltage Circuit-Breakers AP/ 7.5 kv up to 550 kv Power Transmission and Distribution The AP/ High-Voltage Circuit-Breakers Now Applicable for 550 kv Decades of our experience in high-voltage switching
More informationABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
More informationMini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationMR6 MR30. limit switches Compacta slip-on geared motors with integrated limit switches (figure 1) are ideal drives for reversing tasks (figure 2).
Slip-on geared motors Compacta General MST MR6 MS12 cutaway AG60 cutaway MR30 Compacta limit switches Compacta slip-on geared motors with integrated limit switches (figure 1) are ideal drives for reversing
More informationF454. Web Server. User Manual 05/12-01 PC
F454 Web Server User Manual 05/2-0 PC 2 Web Server Contents Introduction and basic functions 5. Connection modes 6.. Connection to the data network 6..2 Remote connection 6.2 Using the Web Server with
More informationReplacement Parts. Starters and Contactors AC Coils. Selection. Ordering Information
Starters and Contactors AC Coils Ordering Information 4th character of starter or contactor catalog number indicates model. 17 CONTROL AC Coils For Class 14, 17, 18, 22, 25, 26, 30, 32, 36, 37, 40, 43,
More informationAUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A
AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components
More informationSiemens Industry Online Support Searching and filtering - keyword search. Search Alternative 1. Keyword search
Searching and filtering - keyword search Search Alternative 1 Keyword search Enter one or more keywords in the search box on the home page. For example: - Contactor 5.5 kw - S7 1200 - Frequency converter
More informationType: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationOverload Relay Heater Tables
Overload Relay Tables of Elements for Overload Relays Use only when motor full load current is not known. Motor amps will vary depending on the type and manufacturer of the motor. These average values,
More informationBED TYPE MILLING CENTRE
TR BED TYPE MILLING CENTRE TR BED TYPE MILLING CENTRE BED TYPE MILLING CENTRE HIGH PERFORMANCE IN A COMPACT MACHINE PROVIDING ACCURATE COMPLEX MILLING TR BED TYPE MILLING CENTRE The TR milling centre is
More informationBETA Protecting SITOR Semiconductor Fuses
BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field
More information3RV Motor Starter Protectors up to 100 A
General data Overview S0 motor 3RV1 motor are compact, current limiting motor which are optimized for load feeders. The motor are used for switching and protecting three-phase induction motors of up to
More informationMeter Relays. 077 Series Analogue Meter Relays. Features. Applications
077 Series Analogue Features Monitors and controls any variable which can be converted to an A.C. or D.C. signal. Rugged, shock and vibration resistant design Indicator, relays and power unit in one housing
More informationAFE424 SERVICE PARTS
This is the parts list for the AFE. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The Air Cooled model has also been manufactured
More informationWiring Diagram. Diplomat 400V 3N. www.thermia.com
www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.
More informationSOLENOID VALVES AND PNEUMATIC VALVES
2 A S E R I E S Catalogue 2005-2006 Directly operated solenoid valves Series A 2/2 way, 3/2 way monostable, bistable (with magnetic memory) Ports M5,, cartridge ø4 The Series A solenoid valves are of the
More informationType: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
More informationRefrigeration Air Dryers. Catalogue
Refrigeration Air Dryers Catalogue GB Using a dryer is worth it Humidity is a component of atmospheric air, which can be found in our compressed air distribution systems and the machines that use the compressed
More informationCatalog January. Heavy industrial power applications Motor contactors and starters
Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type
More informationTechnical Specification. Generating Set with Waukesha engine burning natural gas
Technical Specification Generating Set with Waukesha engine burning natural gas The following presents the Gas Engine Generating Set (GEGS) APG1000 type, based on Waukesha gas engine 16V150LTD. Using the
More informationIndustrial Controls SIRIUS Controls
Industrial Controls SIRIS Controls Star-delta (Wye-delta) Switching of Three-phase Induction Motors Transient Current Peak Reduction using a Preferred Circuitry Configuration for Clockwise and Counterclockwise
More informationCOOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C
COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing
More informationCommercial code: 63076
Model type: TVM63XNA Commercial code: 63076 General notes Technical Documentation guidelines ----------------------------------------------------------------------------------------------------------------------------------
More informationChanges for the Better MITSUBISHI. MELDAS AC SERVO MDS-B-SVJ2 Series Manual for Replacing BNP-B2202B (ENG) MITSUBISHI ELECTRIC
Changes for the Better MITSUBISHI MELDAS AC SERVO MDS-B-SVJ2 Series Manual for Replacing BNP-B2202B (ENG) MITSUBISHI ELECTRIC 1. Introduction This manual contains points to change and examine when replacing
More informationCondensing unit type EPSILON-ECHOS LE Technical information manual
Condensing unit type EPSILON-ECHOS LE Technical information manual 2 > EPSILON ECHOS Water chiller > EPSILON ECHOS /HP Reversible heat pump > EPSILON ECHOS /ST Water chiller with storage tank and pumps
More informationSwitching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches
Siemens AG 2014 Switching Devices /2 Introduction /5 5TE control switches / 5TE4 pushbuttons /11 5TE5 light indicators /13 5TE On/Off switches /20 5TE DC isolators /22 5ST busbars for modular installation
More informationWON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin 30-34 / March 2013
Bulletin 30-34 / March 2013 INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES General The information on the following pages is to provide the installer the necessary information to properly install the
More informationSiemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.
The perfect solution for basic servo applications Brochure May 2011 SINAMICS Answers for industry. with 1FL5 servomotors The solution for basic servo applications There is a requirement to automate motion
More informationOVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear.
OVERCURRENT & EARTH FAULT RELAYS Objective: To study the protection of equipment and system by relays in conjunction with switchgear. Theory: The function of a relay is to detect abnormal conditions in
More informationChilled Water Fan Coil Unit
Chilled Water Fan Unit Model: HFCF02~HFCF14 Airflow Range: 200~2400m 3 /h Features and Benefits The Best Choice for Comfort The Best Results - Quiet Comfort Low noise permanent split capacitor motor. Metal
More information8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
More informationUNIT 1 GCSE PHYSICS 2011 FXA. 1.3.1 Transferring Electrical Energy APPLIANCE USEFUL ENERGY NON-USEFUL ENERGY
UNIT 1 Examples of energy transformations that everyday electrical devices bring about. APPLIANCE USEFUL ENERGY NON-USEFUL ENERGY 40 The amount of electrical energy a device transforms depends on how long
More informationThe Interaction of Contactors with PLCs
www.eaton.com/moellerproducts The Interaction of Contactors with PLCs Technical Paper Dipl.-Ing. Wolfgang Nitschky Design and function of the DC operated contactors DILM7 to DILM170 The market for DC operated
More informationType: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
More informationABB Solutions for HVAC Heating, ventilation and air conditioning. Components and systems
ABB Solutions for HVAC Heating, ventilation and air conditioning Components and systems Anyone designing and manufacturing air conditioning equipment and systems is well aware of the expectations of their
More informationABB Solutions for Original Equipment Manufacturers. Components and equipment
ABB Solutions for Original Equipment Manufacturers Components and equipment Industrial IT is a new concept developed by ABB that integrates all levels of a company s activities, incorporating, in one single
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More informationFigure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.
Crydom RHP Series 3 Phase Hybrid Solid State Contactor By Paul Bachman Fellow Engineer, Crydom, Inc. ABSTRACT Solid State Relays and Contactors (SSRs) have been available in one form or the other for over