300 MY HOME Energy management

Size: px
Start display at page:

Download "300 MY HOME Energy management"

Transcription

1 300 MY HOME

2 COTETS. MY HOME oad control management General features. 302 General rules for installation. 308 Configuration 311 Wiring diagrams. 314 MY HOME 301

3 GEERA FEATURES The end of the black-out The My Home load control management system manages the maximum power used, by automatically disconnecting the least important appliances in case of overload The system: Manages up to 63 loads Displays on the display interfaces (e g ocal Display,, Webserver) the instantaneous and cumulative consumption on hourly, daily, and monthly basis, of the controlled phase In addition, thanks to the actuator with sensor, it is possible to measure the actual consumption of the controlled load It gives the possibility of disabling or re-enabling, using the display interfaces, the priorities configured based on the changed needs of the customer It gives the possibility of checking on the display interfaces the correct operation of the load using the measurement of the earth leakage current absorbed by the same Its devices (central unit and actuators) only require the space of one DI module This ensure optimisation of spaces inside the distribution boards By configuring the actuators of the load control system in automation mode, it is possible to use display interfaces to set the time delays for the activation of the loads at set times Dedicated icon on the screen of the touch screen 302 MY HOME

4 Power consumption screen (instantaneous / cumulative) Monthly power consumption graph Controlled loads screen Controlled load consumption display screen (with item F522) Diagnostic icon Energy consumption display icon oad control management icon MY HOME 303

5 GEERA FEATURES Operation Using the external toroid, the central unit measures the power used by the loads connected and compares it with the value preselected during the installation (using the configurators it is possible to select powers between 1 5 and 18 kw, with tolerances up to +/- 20%) An actuator is associated to each appliance being controlled The actuator receives the information from the central unit and disconnects the load from the network in case of overload The disconnection sequence of the actuators is defined during the installation using a simple configuration operation to be carried out on the devices themselves The central unit gives the possibility of managing up to 63 priority levels, Power meter Electric distribution board and a number of devices depending on the available supply current In the example shown, the oven, the microwave oven, and the washing machine represent the loads controlled using actuators, while the refrigerator, which operation is imperative that is not interrupted, is connected to his socket without actuator In case of overload, the first device that disconnects is the one considered the least important by the user, in the example the oven, which actuator has configurator no 1 The microwave is on the other hand the most important device, and the corresponding actuator Central unit for load management has configurator no 3 This load therefore only disconnects after the oven and the washing machine The user can reactivate the disconnected device at any time using the actuator pushbutton or the touch screen In this case, if the overload condition still exists, the central unit will enable the operation of the selected load, but will disconnect the subsequent loads starting from the least important, until the overload situation is resolved The operating status of the loads is notified both by the actuators and the touch screens By configuring the actuators of the load control management system also in automation mode, it is possible to use the touch screen to set the time delays for the activation of the loads at set times BUS on-controlled socket Flush mounted actuator Flush mounted actuator Flush mounted actuator on-controlled load OTE: inside the electric distribution board it is installed the central unit for load management Controlled load with priority 1 Controlled load with priority 2 Controlled load with priority MY HOME

6 DISPAY FUCTIO The central unit for load management is capable of measuring the consumption of the controlled line using the toroid supplied The information is displayed on the touch screens, local displays, and on the web pages of the web server and the energy data logger DIAGOSTIC FUCTIO Thanks to the actuator with probe (Item F522), it is possible to display, in addition to consumptions, also the diagnostic, using the additional toroid (item ) of the controlled load The processing and accounting functions are: instantaneous consumption of the controlled line; hourly, daily, monthly and last 12 months cumulative consumptions Controlled loads diagnostic display screen Diagnostic icon oad OK oad near the earth leakage disconnection limit oad problems (e.g. device earth connection problems) MY HOME 305

7 GEERA FEATURES Device selection criteria CETRA UIT FOR OAD MAAGEMET F521 The device is capable of measuring the input power from the electric system and to control the status of the actuators of the load management system, to prevent the risk of tripping of the power meter The central unit manages up to 63 appliances or electric loads per each phase, measures currents and voltages, and processes these data to provide energy and power information The processing and accounting functions are: instantaneous consumption of the controlled line; cumulative hourly consumptions for the last 12 months, daily consumptions for the last 2 years, monthly consumptions for the last 12 years The central unit is suitable for installation inside distribution boards and switchboards and requires the space of 1 DI module Actuator 16A with current probe connection ACTUATOR 16 A WITH CURRET PROBE - ITEM F522 The device is an actuator with an integrated current probe for the measurement of controlled load consumptions (instantaneous consumption and 2 independently resettable energy totalizers), and is capable of performing both EERGY MAAGEMET and automation functions When configured in EERGY MAAGEMET mode, it gives the possibility of measuring the load input power, the power and the earth leakage current (through the connection of an external toroid, item ) The actuator is suitable for installation inside distribution boards and switchboards and requires the space of 1 DI module Central unit for load management Device status ED oad forcing pushbutton 16A actuator connection Configurator socket door connection Device status ED oad forcing pushbutton Device status ED oad forcing pushbutton Configurator socket door /BUS connection Configurator socket door /BUS connection /BUS connection 306 MY HOME

8 ACTUATOR 16A F523 The device is an actuator capable of performing both energy management and automation functions The actuator is suitable for installation inside distribution boards and switchboards and requires the space of 1 DI module oad status red ED Device status two-colour ED FUSH MOUTED ACTUATOR 16 A ITEMHC/HS/HD///T4672 Actuator conceived for installation in iving, ight, ight Tech and Axolute flush mounted supports, intended for the automation and/or EERGY MAAGEMET functions The device has: a local load forcing pushbutton; a red/green two-colour ED for the notification of the status of the actuator; central unit for load management red disabling signalling ED ocal pushbutton for load forcing/local control OAD COTRO PAE HD/HC/HS///T4673 The load control panel is a device that enables displaying the status of the loads controlled by the load control central unit, item F521, and force their operation independently from the central unit itself It is therefore possible to: Force the priority of the load during normal operation In this case the central unit cannot disable the load for 4 hours Re-enable a load disabled by the central unit, the duration of this operation lasts for 4 hours, unless the disabling key is pressed manually The functions that can be performed by the load control panel can also be performed by ocal Display (HD/HC/HS///T4685) With ocal Display it is however possible to manage up to 20 loads Flush mounted 16 A actuator Forced load key oad/programming status notification ED ocal Display oad control panel MY HOME 307

9 GEERA RUES FOR ISTAATIO oad control management and consumption display BUIDIG AYOUT The BUS system layout for the installation of oad Control Management System and the Display of Consumptions System offers the following advantages: Both for new systems, and installation in existing electric systems, the BUS line can use the same conduits of the energy system used for the wiring of power sockets However, this is only possible when using the BUS cable, Item 4669, with insulation voltage 300/500 Vdc Depending on the needs of the user and the type of building, the load control actuators may be installed: 1. in DI distribution board, if it is not required to display and reactivate the load directly in the room where the load is located; 2. near each current socket for the load to be controlled, to ensure the possibility of controlling the status and/or forcing the load PHYSICA IMIT The maximum number of devices that can be connected to the BUS (central unit for load management, actuator, power meter, and pulse counter interface) depends on the total absorption of the same, and on the distance between the connection point and the power supply If the system uses the same cable as the Automation/temperature control system, the calculation of the maximum number of devices must be performed taking into account the general absorption of the same For the purpose of the above calculations, the table shows the current absorbed by each device MAXIMUM UMBER OF ACTUATORS The Central Unit for oad Management can control up to 63 actuators (appliances or electric loads) If the system is solely dedicated to oad Management, or if it shares the same BUS line of the Automation/ Temperature control system, the number of actuators shall depend on the limit of the available current ITEM DEVICE ABSORPTIO FROM BUS F521 Central unit for load management 28 ma F522 Actuator with probe 30 ma F523 Basic actuator 10 ma HD/HC/HS///T4672 Flush mounted actuator 10 ma H AM5864 Touch screen ma HD/HC/HS4690 Multimedia Touch screen ma F520 Bus meter with toroids 35 ma Pulse counter interface 7.5 ma HD/HC/HS///T4673 oad control panel 7 ma HD/HC/HS///T4685 ocal Display 60 ma F524 Energy data logger 30 ma 308 MY HOME

10 1. The length of the connection between the power supply and the furthest device cannot exceed 250 m Actuator Junction box Home automation distribution board Furthest device 2. The total length of the connections must not exceed 500 m (extended cable) Actuator Junction box Home automation distribution board MY HOME 309

11 PRI PRI: V~ ma 50/60 Hz : 27 Vdc 600 ma GEERA RUES FOR ISTAATIO oad control management and consumption display In order to ensure optimum distribution of the currents on the BUS line, it is recommended to position the power supply in an intermediate position A A B B With E46ADC power supply: A = 250 m max B = 250 m max A + B =500 m The maximum current supplied by the power supply is: 1200 ma With power supply: A = 250 m max B = 250 m max A + B =500 m The maximum current supplied by the power supply is: 600 ma OTE: If a UTP5 cable is used instead of a BUS 4669 cable, distances must halved. 310 MY HOME

12 COFIGURATIO oad control management and consumption display The load management control and consumption display systems must be correctly configured to ensure that they can operate correctly, and that each item can perform the desired function The mode of configuration must be the physical one The physical configuration entails interaction with the devices - pulse counter interface (Item ), bus meter with 3 inputs for toroids (Item F520), central unit for load management (Item F521), load control actuators (Item F522, F523, The products may be split in two //T/HC/HS/ HD4672) and classes: consists in physically connecting 1. Pulse counter interface (item the connection components, called ), Bus meter with 3 inputs for configurators to the appropriate toroids (item F520), Central unit for housings of the devices load management (item F521) All The configurators have different these devices have an address from numbers, letters, colours, or graphics 1 to 127 COFIGURATOR SOCKET COFIGURATORS USED A1 is the configurator indicating the hundreds 0, 1 A2 is the configurator indicating the tens From 0 to 9 A3 is the configurator indicating the units From 1 to 9 A3-Ta From 1 to 9 (a configurator must be in this housing) A3-Tb From 1 to 9 A3-Tc From 1 to 9 WARIG: The 0 configurator in A3-Tb, A3-Tc indicates that the toroid input is not being used. A3 or A3Ta cannot be equal to 0. In the case of the bus meter with 3 inputs for toroids, item F520, if only one toroid is used, this must be connected to A3-Ta. Configuration examples: For bus meter with three inputs for toroids, item F520, and pulse counter interface, item : VAUE OF COFIGURATORS ADDRESSES WARIG: The devices in this class must be a different address from each other: for example, there cannot be Bus meter with toroids A1 A2 A3-Ta A3-Tb A3-Tc A1 A2 A3-Ta A3-Tb A3-Tc Toroid connected to Ta with address 001 Toroid connected to Tb with address 002 Toroid connected to Tc with address 003 Toroid connected to Ta with address 126 Toroid connected to Tb with address 127 o toroid connected to Tc a pulse counter interface and a bus meter with three inputs for toroids with the same address. Also two toroids cannot have the same address. In case two consumption/load control devices are installed on an automation or temperature control bus, the configured addresses are not in conflict with the other devices on the system: a temperature control probe configured with address 11 is not in conflict with a bus meter with 3 inputs for toroids with address 11. Pulse counter interface A1 A2 A3 G M SM Pulse counter interface address 004 It is possible to manage up to 20 lines (toroids) maximum per power supply. Example: 6 meters for 3 lines plus 1 meter for 2 lines (total 20). MY HOME 311

13 COFIGURATIO oad control management and consumption display 2. oad control actuators: The actuators may be used both as automation actuators and EERGY MAAGEMET actuators The configuration in automation mode follows the same rules outlined in the automation guide (see the device TECHICA SHEETS); the configuration in Energy Management mode requires a progressive address programs in the touch screens, and from 1 to 63 define the disconnection priorities for These addresses are used in the the controlled load appropriate configuration software COFIGURATOR SOCKET COFIGURATORS USED P1 is the configurator indicating the tens From 0 to 6 P2 is the configurator indicating the units From 0 to 9 Configuration examples: For actuator 16 A with probe Item F522 and actuator 16 A Item F523: Actuator 16 A with probe Actuator 16A COSUMPTIO DISPAY COFIGURATIO After installing the devices (Pulse counter interface, item, bus meter with 3 inputs for toroids, Item F520, central unit for load management, Item F521), an address must be assigned using physical configurators (A1, A2, A3) This address will then be used in the software for the configuration of the user interfaces (e g software for the configuration of the 3 5 touch screen) For more information see the relevant product technical sheet 312 MY HOME VAUE OF COFIGURATORS A P M P1 P2 PF 0 1 A P M G P1 1 P2 0 ADDRESSES Address priority 01 Address priority 10 OAD COTRO SYSTEM COFIGURATIO After installing the devices and configuring the actuators, it is necessary that the central unit for load management acquires the actuators on the bus, and the corresponding priorities configured For more information see the technical sheet of the central unit for load management, item F521, and the TECHICA SHEET for the actuators WARIG: In the case of consumption display/ load control actuators installed on an automation or temperature control bus, and configured also in automation mode (A, P...), the load control actuator must not have the same address as another actuator on the automation bus. Example: if actuator F411/1 A = 1 P = 1, then actuator F522 cannot be configured with P=1. SYSTEM EXPASIOS The energy management system is a very flexible system, for the installation of the devices on the automation/ temperature control bus, or for creating a system solely dedicated to energy management, with dedicated power supply in general, all energy management devices may be installed on each bus branch and on each expansion, provided this is allowed by the absorption calculations The only exceptions are the actuators, which, when configured in automation mode, during system expansions follow the same rules of the automation bus (automation technical guide)

14 AVAIABE FUCTIOS DEVICES Power bus meter with 3 inputs for toroids Central unit for load management Actuator 16 A with current probe Actuator 16A Flush mounted Actuator 16 A Pulse counter interface oad management panel I A1 A2 A3 G M SM OUT Visualisation oad control Diagnostic 1) OTE 1) : in combination with additional toroid, item AVAIABE FUCTIOS DEVICES ocal display Touch screen 3,5 Touch screen 10 Energy data logger Webserver Visualisation oad control Diagnostic 1) MY HOME 313

15 PRI: V~ ma 50/60 Hz : 27 Vdc 600 ma A1 A2 A3 G M SM A1 A2 A3 G M SM WIRIG DIAGRAMS Display of electricity, water and gas consumptions ITEM RCCD MCB1 F520 DESCRIPTIO General switch 4 A MCB switch Compact power supply Bus meter with three inputs for toroids Toroid 3.5 / Multimedia 10 Pulse counter interface WARIG The following s may be installed: - H4684 AXOUTE IVIG / IGHT / IGHT TECH - AM5864 MÀTIX - Multimedia HD/HC/HS4690 Each F520 is supplied as standard with one toroid, item To the other users The general switch RCCD must be selected depending on general absorption. For better safety and comfort, the installation of an additional STOP&GO device is also recommended. IG MGT1 4A Modem Router/ Switch PRI F520 A3 TA = 1 A3 TB = 0 A3 TC = 0 F524 BUS/ Switchboard or distribution board I OUT A3 = 2 M = 1 SM = 0 I OUT A3 = 3 M = 3 SM = 0 Zener Barrier/Galvanic insulation Barrier 1) OTES: 1) the barrier must meet the Atex requirements and must be installed outside the Atex area. Gas meter with pulse output Water meter with pulse output 314 MY HOME

16 PRI PRI: V~ ma 50/60 Hz : 27 Vdc 600 ma Display of electric consumptions on several lines ITEM F520 RCCD MCB1-5 MCB6 DESCRIPTIO Compact power supply Bus meter with three inputs for toroids Toroid 3.5 / Multimedia 10 General switch inear protection switch 4 A MCB switch WARIG The following s may be installed: - H4684 AXOUTE IVIG / IGHT / IGHT TECH - AM5864 MÀTIX - Multimedia HD/HC/HS4690 General MCB switches must be selected depending on load absorption Each F520 is supplied as standard with one toroid, item The general switch RCCD must be selected depending on general absorption. For better safety and comfort, the installation of an additional STOP&GO device is also recommended. IG MGT1 MGT2 MGT3 MGT4 MGT5 Socket line 1 Socket line 2 ine 3 lighting ine 4 appliances ine 5 Temperature control (hot and cold) MGT6 F881A/4 F520 A3 TA = 1 A3 TB = 2 A3 TC = 3 F520 A3 TA = 4 A3 TB = 5 A3 TC = 6 Switchboard or distribution board BUS/ To other devices if present MY HOME 315

17 PRI PRI: V~ ma 50/60 Hz : 27 Vdc 600 ma A1 A2 A3 G M SM WIRIG DIAGRAMS Display of produced and consumed energy WARIG ITEM F520 RCCD MCB1-2 DESCRIPTIO Compact power supply Bus meter with three inputs for toroids Toroid Pulse counter interface 3.5 / Multimedia 10 General switch MCB protection switch If a photovoltaic system and a thermal solar system for the production of energy and hot water are installed, by using energy measurement devices and the pulse counter interface the user can display the energy produced, or the amount of heated water on the touch screen. The following s may be installed: - H4684 AXOUTE IVIG / IGHT / IGHT TECH - AM5864 MÀTIX - Multimedia HD/HC/HS4690 General MCB switches must be selected depending on load absorption Each F520 is supplied as standard with one toroid, item, for current reading Wh Photovoltaic generator string The general switch RCCD must be selected depending on general absorption. For better safety and comfort, the installation of an additional STOP&GO device is also recommended. Input/output meter Wh MGT1 IG Inverter String distribution board + + MGT2 F520 F520 A3 TA = 1 A3 TB = 0 A3 TC = 0 BUS/ A3 TA = 2 A3 TB = 0 A3 TC = 0 To other devices if present A3 = 3 M = 3 SM = 0 I Water meter with pulse outout Storage battery OUT 316 MY HOME

18 PRI: V~ ma 50/60 Hz : 27 Vdc 600 ma Display of produced and consumed energy in exchange mode on location WARIG ITEM F520 RCCD MCB1-3 DESCRIPTIO Compact power supply Bus meter with three inputs for toroids Toroid 3.5 / Multimedia 10 General switch MCB protection switch In the presence of a photovoltaic panels system configured for a delivery of energy in local exchange mode, the bus meter with 3 inputs for toroids can be installed as shown in the figure: one toroid measures the current produced by the photovoltaic panels, the other the home consumption. WARIG: avoid fitting the measuring toroid directly on the main bidirectional meter. The following s may be installed: - H4684 AXOUTE IVIG / IGHT / IGHT TECH - AM5864 MÀTIX - Multimedia HD/HC/HS4690 General MCB switches must be selected depending on load absorption Each F520 is supplied as standard with one toroid, item, for current reading The general switch RCCD must be selected depending on general absorption. For better safety and comfort, the installation of an additional STOP&GO device is also recommended Wh Production meter Photovoltaic generator string Input/ output meter Wh MGT1 Inverter String distribution board MGT2 + + IG MGT3 F520 PRI A3 TA = 1 A3 TB = 2 A3 TC = 0 BUS To other devices if present MY HOME 317

19 C C C 13 : 38 Ven 07 Gen OK 18.0 C 13 : 38 Ven 07 Gen OK A1 A2 A3 G M SM WIRIG DIAGRAMS Display of the consumption of thermal power / hot water by individual home ITEM E46ADC F430/2 F430/4 DESCRIPTIO Power supply 4 zone central units probe with adjustment knob 2 relay DI actuator 4 relay DI actuator Pulse counter interface 3.5 / Multimedia Touch Screen 10 In an establishment with central heating, by connecting a Pulse counter interface to the pulse output of the meter of a My Home system, it is possible to display on the touch screen the data made available by the meter (water consumption of the individual home, thermal power). The meter must be have pulse outputs, and must be installed at the input of the distribution manifold. WARIG The following s may be installed: - H4684 AXOUTE IVIG / IGHT / IGHT TECH - AM5864 MÀTIX - Multimedia HD/HC/HS4690 The following 4 zone central units may be installed: - HC/HS4695 AXOUTE - //T4695 IVIG/IGHT/IGHTECH - AM5875 MATIX Home n ZOE 3 ZOE 2 +1 OFF OFF The following probes with knob may be installed: - HC/HS4692 AXOUTE - //T4692 IVIG/IGHT/IGHTECH - AM5872 MATIX 23.7 ZOE 4 ZOE 1 C +1 OFF Home 2 ZOE 3 ZOE 2 +1 OFF OFF Solenoid valve Solenoid valve Solenoid valve Solenoid valve Home 1 ZOE ZOE 1 C +1 OFF Central boiler F430/2 F430/4 E46ADC M Mixing valve Meter Main solenoid valve Mixing valve management central unit ART. F430/2 ART. F430/4 C1 C2 C1 C2 C3 C4 C OK BUS/ OFF OFF OFF A3 = 1 M = 2 SM = 0 I OUT OTE: the pulse counter interface is recommended (M=2) to detect the thermal power 318 MY HOME

20 PRI PRI: V~ ma 50/60 Hz : 27 Vdc 600 ma oad control management with total consumption display ITEM DESCRIPTIO WARIG F521 F523 RCCD MCB Compact power supply Central unit for load management 16 A 1 M DI basic actuator Toroid 3.5 / Multimedia Touch 10 General switch 4 A MCB switch Flush mounted actuator The following s may be installed: - H4684 AXOUTE IVIG / IGHT / IGHT TECH - AM5864 MÀTIX - Multimedia HD/HC/HS4690 The following 2 module flush mounted 16 A actuators may be installed - HC/HS/HD4672 AXOUTE - //T4672 IVIG/IGHT/IGHTECH General MCB switches must be selected depending on load absorption The general switch RCCD must be selected depending on general absorption. For better safety and comfort, the installation of an additional STOP&GO device is also recommended MGT1 MGT2 Each F520 is supplied as standard with one toroid, item, for current reading IG oad oad oad Touch Screen A3 = 1 P = 0 TO = 5 F521 F523 F523 A = 0 P = 0 M = 0 P1 = 0 P2 = 2 A = 0 P = 0 M = 0 P1 = 0 P2 = 1 A = 0 P = 0 M = 0 P1 = 0 P2 = 3 BUS/ Switchboard or distribution board MY HOME 319

21 PRI PRI: V~ ma 50/60 Hz : 27 Vdc 600 ma WIRIG DIAGRAMS oad control management with total display, of loads and diagnostics ITEM F521 F523 F522 RCCD MCB1 DESCRIPTIO Compact power supply Central unit for load management 16 A 1 M DI basic actuator Actuator 16 A with probe Toroid 3.5 / Multimedia 10 General switch 4 A MCB switch WARIG The following s may be installed: - H4684 AXOUTE IVIG / IGHT / IGHT TECH - AM5864 MÀTIX - Multimedia HD/HC/HS4690 General MCB switches must be selected depending on load absorption Each F520 is supplied as standard with one toroid, item, for current reading MGT1 MGT2 The general switch RCCD must be selected depending on general absorption. For better safety and comfort, the installation of an additional STOP&GO device is also recommended F522 actuator 16 A with integrated current probe, capable of measuring the consumptions of the controlled load. By connecting a toroid, item to the device, it is possible to measure the earth leakage current and display the load status on the Touch screen. IG oad oad oad oad F521 F522 F523 F522 F522 A3 = 1 P = 0 TO = 5 A = 0 P = 0 M = 0 P1 = 0 P2 = 2 PF = 5 A = 0 P = 0 M = 0 P1 = 0 P2 = 1 A = 0 P = 0 M = 0 P1 = 0 P2 = 3 PF = 0 A = 0 P = 0 M = 0 P1 = 0 P2 = 4 PF = 0 BUS/ Switchboard or distribution board 320 MY HOME

22 PRI: V~ ma 50/60 Hz : 27 Vdc 600 ma PRI: V~ ma 50/60 Hz : 27 Vdc 600 ma PRI: V~ ma 50/60 Hz : 27 Vdc 600 ma Three-phase and one-phase load control management ITEM F521 F523 MCB FC4A Vac R S T DESCRIPTIO Compact power supply Central unit for load management 16 A 1 M DI basic actuator Toroid MCB switch AC contactor WARIG General MCB switches must be selected depending on load absorption The contactor must be selected depending on the absorption of the load The three-phase line must be balanced R S T MGT1 MGT2 R Single-phase load PRI F521 A3 = 1 P = 1) TO = 1) F523 A = 0 P = 0 M = 0 P1 = 0 P2 = 1 F523 A = 0 P = 0 M = 0 P1 = 0 P2 = 2 BUS/ 1 F521 F523 PRI A3 = 1 P = 1) TO = 1) A = 0 P = 0 M = 0 P1 = 0 P2 = 1 R FC4A... BUS/ 2 F521 F523 PRI A3 = 1 P = 1) TO = 1) A = 0 P = 0 M = 0 P1 = 0 P2 = 1 BUS/ 3 Three-phase load OTE: 1) the configurators must be selected depending on the rated power MY HOME 321

F454. Web Server. User Manual 05/12-01 PC

F454. Web Server. User Manual 05/12-01 PC F454 Web Server User Manual 05/2-0 PC 2 Web Server Contents Introduction and basic functions 5. Connection modes 6.. Connection to the data network 6..2 Remote connection 6.2 Using the Web Server with

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Transponder reader CÉLIANE TECHNICAL GUIDE

Transponder reader CÉLIANE TECHNICAL GUIDE CÉLIAE TECHICAL GUIDE Description The transponder reader is a device that activates when the appropriate badge is placed in front of it (1-2 cm). The badge is the transponder. The signal generated by placing

More information

ZigBee Wireless Sensor Networks

ZigBee Wireless Sensor Networks ZigBee Wireless Sensor Networks Wireless Devices for Monitoring and Data Harvesting Home & Building Automation Automated Meter Reading Energy Management Renewable Monitoring Environment Monitoring ZigBee

More information

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer

More information

Anti-blackout system for grid connected solar installations (Solsafe concept)

Anti-blackout system for grid connected solar installations (Solsafe concept) Anti-blackout system for grid connected solar installations (Solsafe concept) General description The Solsafe concept is a system which will automatically switch from a grid feeding inverter connected

More information

Failure code manual. content

Failure code manual. content Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy

More information

Integrated solutions for comfort, energy efficiency, safety, video door entry, and control

Integrated solutions for comfort, energy efficiency, safety, video door entry, and control Integrated solutions for comfort, energy efficiency, safety, video door entry, and control AUTOMATION Thanks to a wide range of s, MyHOME offers simple and efficient solutions to meet the safety, comfort,

More information

EQUIPMENT SPECIFICATIONS

EQUIPMENT SPECIFICATIONS EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access

More information

SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General

SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General A. Electrical usage on the Brown campus is presently monitored by a Siemens-brand, web-based central metering system, which includes

More information

Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications

Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications The ZigBee Plug & Play wireless Network for Building and Industrial Applications Energy Management Renewable Monitoring Environment Monitoring Open Modbus Integration Products Range Overview Products Range

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

F453. TiF453. User guide 10/11-01 PC

F453. TiF453. User guide 10/11-01 PC F453 TiF453 User guide 10/11-01 PC 2 TiF453 User guide Contents 1. Hardware and Software requirements 4 2. Installation 4 1.1 Minimum Hardware requirements 4 1.2 Minimum Software requirements 4 3. Fundamental

More information

Conventional Fire Detection and Extinguishant Control System Specification

Conventional Fire Detection and Extinguishant Control System Specification Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, 18 80 W Compact and T5c fluorescent lamps

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, 18 80 W Compact and T5c fluorescent lamps Product description Noise-free precise control via DSI signal or switchdim CELMA energy class A1 1) Interfaces DSI switchdim Integrated SMART-Interface Functions Optimum filament heating in any dimmer

More information

Thermostat with display

Thermostat with display H/LN4691-0 674 59-64170 Thermostat with display RA00118AA_I-01PC-13W39 www.homesystems-legrandgroup.com Thermostat with display Contents Thermostat with display 1 Introduction 4 1.1 Warnings and recommendations

More information

TECHNICAL BRIEF. Commercial PV in Australia and New Zealand Using the Enphase Microinverter System

TECHNICAL BRIEF. Commercial PV in Australia and New Zealand Using the Enphase Microinverter System TECHNICAL BRIEF Commercial PV in Australia and New Zealand Using the Enphase Microinverter System 2015 Enphase Energy Inc. All rights reserved May 2015 Table of Contents Commercial PV in Australia and

More information

Counter for Energy. We make energy measurable and secure your future. www.g-mw.de

Counter for Energy. We make energy measurable and secure your future. www.g-mw.de Counter for Energy We make energy measurable and secure your future www.g-mw.de 10 reasons for GMW Customer oriented solutions Individual consultancy Satisfied customers in all continents Large range of

More information

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short

More information

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way

More information

Off-grid solar and backup power installations

Off-grid solar and backup power installations Off-grid solar and backup power installations A World of Power Problems... Residential Backup Power Grid-Interactive 3-Phase Commercial Buildings with Backup Power Grid-Interactive Residential with Backup

More information

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5 Eaton Wiring Manual / Page Overview - ON-OFF switches, main switches, maintenance switches - Changeover switches, reversing switches - (Reversing) star-delta switches - Multi-Speed Switches - Interlock

More information

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management Energy Depot GmbH Delivering Solutions for Energy Management PRODUCT AND APPLICATION GUIDE Total Monitoring Solution for PV SOLAR LOGGER & ANALYSIS DC STRING MONITORING Residential Comprehensive Solar

More information

A project to optimise quality and energy efficiency must include metering

A project to optimise quality and energy efficiency must include metering EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,

More information

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions DAI DIM/COVERTER COTRO (DC V) 1 10V (0-10 V) analog DAI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions Dim-and Switch Functions: The DAI Dim/Converter Control DC V is suitable

More information

Vitosoft 200 Vitodata 300 Vitocom 300 Vitocom 100

Vitosoft 200 Vitodata 300 Vitocom 300 Vitocom 100 Contents Page 1, type FA1 1.1 Function description................................................................................... 6 1.2 Pre requisites.............................................................................................

More information

How To Build A Home Automation System On A Tv Remote Control

How To Build A Home Automation System On A Tv Remote Control TECHNICAL GUIDE 2011 MY HOME Design and installation guide CONTENTS MY HOME INTRODUCTION General features........................2 1MY HOME -INTRODUCTION INTRODUCTION - GENERAL FEATURES MY HOME - Build

More information

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850

More information

2 WIRE video door entry system

2 WIRE video door entry system J J N P CLASSE 00 VE WIRE video door entry system 5 Description Front view WIRE handsfree colour video handset with inductive loop, preset for different types of installations, depending on the accessories

More information

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, 18 80 W Compact and T5c fluorescent lamps

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, 18 80 W Compact and T5c fluorescent lamps EXCEL oneall series Product description Noise-free precise control via DSI signal, switchdim, corridorfunction or DALI DALI-MEMORY Extended DALI commands CELMA energy class A1 1) Interfaces DALI DSI switchdim

More information

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services Circuit Breakers and Switchgear Thomas Greer Director of Engineering TLG Services Presentation Outline Switchgear Definition Overcurrent Protection Devices Circuit Breaker Trip Curves and Coordination

More information

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards. 56 / Accessories for inverters Accessories for inverters / Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards. FRONIUS STRING

More information

SYSTEM MONITORING Locally and remotely

SYSTEM MONITORING Locally and remotely StecaGrid 300 StecaGrid 500 StecaGrid 2000+ StecaGrid 2010+ StecaGrid 2020 StecaGrid 3000 StecaGrid StecaGrid 4200 StecaGrid StecaGrid 10000+ 3ph StecaGrid 8000 3ph StecaGrid 10000 3ph monitoring StecaGrid

More information

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System TICS - Total Integrated Control Strategy Mid Range System Underfloor Heating & Cooling Control Solutions Energy efficient Heating and cooling TICS - Mid Range System Mid Range System TICS Mid Range Install

More information

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10 TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified

More information

Inverter / Charger Installation General Operations and AC and DC Connections

Inverter / Charger Installation General Operations and AC and DC Connections Inverter / Charger Installation General Operations and AC and DC Connections The Inverter is just one piece. Sometimes, a tendency is to mount the inverter and batteries, and make it work It is better

More information

CO2 Alarm. Operation. Application

CO2 Alarm. Operation. Application CO Alarm 100-77V AC Supply Voltage Two pre-configured alarm and control thresholds Thresholds factory set to customer requirements on dispersive infrared sensing technology Optional internal audible alarm

More information

3-phase, bidirectional energy meter

3-phase, bidirectional energy meter Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured

More information

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5 T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,

More information

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation DS 500 Intelligent chart recorder for compressed air and gases Measurement - control - indication - alarm - recording - evaluation new Advantages at a glance: Clear layout: 7" colour screen with touch

More information

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE Technical Teaching Equipment Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE EDIBON SCADA System Teaching Technique used 4 5 2 Data Acquisition Board Cables and

More information

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5 F ballasts T PCA T EXCE oneall lp Y, x1/ W and x1/ W EXCE T Product description Processor-controlled ballast with y inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via

More information

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, 14 80 W EXCEL T5

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, 14 80 W EXCEL T5 E T5 TC- PCA T5 EXCE oneall lp Y II, 1 80 W EXCE T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via I or

More information

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000

More information

3-PHASE LOW VOLTAGE NETWORK LOAD BALANCER : A COST EFFECTIVE SOLUTION TO LINE VOLTAGE VARIATIONS

3-PHASE LOW VOLTAGE NETWORK LOAD BALANCER : A COST EFFECTIVE SOLUTION TO LINE VOLTAGE VARIATIONS 3-PHASE LOW VOLTAGE NETWORK LOAD BALANCER : A COST EFFECTIVE SOLUTION TO LINE VOLTAGE VARIATIONS Pierre FRISTOT Olivier CONSTANT Catherine MONCET Omegawatt - France Omegawatt - France SDET - France pierre.fristot@omegawatt.fr

More information

S & P COIL PRODUCTS LTD SPC HOUSE, EVINGTON VALLEY ROAD, LEICESTER. LE5 5LU. Electrical layouts for EC Motors in Fan Convector units

S & P COIL PRODUCTS LTD SPC HOUSE, EVINGTON VALLEY ROAD, LEICESTER. LE5 5LU. Electrical layouts for EC Motors in Fan Convector units S & P COI PRODUCTS TD SPC HOUSE, EVIGTO VAEY ROAD, EICESTER. E5 5U Guidance Document Electrical layouts for EC Motors in Fan Convector units Hasnain Merchant Richard Meskimmon 4/9/0 This document is intended

More information

MicroFIT Connection Application Guidelines

MicroFIT Connection Application Guidelines MicroFIT Connection Application Guidelines These guidelines serve to ensure the efficient processing and implementation of your project. Please read and follow them carefully and completely in order to

More information

D45. SySTEm. ThE high-performance

D45. SySTEm. ThE high-performance D45 ThE high-performance SySTEm Security monitoring system with digital BUS technologies High efficiency system and quick installation for both backbone and riserdevicesthankstotheuse of cat.5e UTP cables

More information

Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities.

Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities. Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities. More Freedom to Administrators Connectable up to 128 Indoor Unit Groups (256 indoor

More information

StruxureWareTM for Buildings

StruxureWareTM for Buildings StruxureWareTM for Buildings Next generation intelligent Building Management System (ibms) Product Catalogue Make the most of your energy Plan for the future while protecting your past investments. 03

More information

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111 , GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,

More information

How to read this guide

How to read this guide How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information

More information

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS Capacity Technology Inverter Technology Noise Level Operating Temperature Humidity Harmonic Distortion Total DC bus voltage Battery recharge time (After Complete discharge) to 100% charge Crest Factor

More information

Achieving the impossible

Achieving the impossible 1 Achieving the impossible Taking control of shore power with the Phoenix Multi/MultiPlus from Victron Energy * Sometimes the features of a new product are so unique that the benefits are difficult to

More information

Applications. diris_826_a_1_gb_cat

Applications. diris_826_a_1_gb_cat Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered

More information

Maximum Demand Control

Maximum Demand Control Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital

More information

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

RVL470. Heating Controller. Building Technologies HVAC Products. Series B 2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones

More information

Reverse-feed applications for circuit breakers

Reverse-feed applications for circuit breakers Technical Publication PU01200001E Contents Description Page Intoduction.......................................................................... 2 breaker classifications..........................................................

More information

386 MY HOME Video door entry and home video surveillance system

386 MY HOME Video door entry and home video surveillance system 386 MY HOME Video door entry and home video surveillance system CTENTS MY HOME - Video door entry and home video surveillance system General features. 388 General rules for installation. 408 Wiring diagrams.

More information

Heating and Hot Water Services Controls General Technical Specification

Heating and Hot Water Services Controls General Technical Specification Construction Services Heating and Hot Water Services Controls General Technical Specification Version 1.0 Environment Heating and Hot Water Services Controls General Technical Specification Contents 1.

More information

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB , GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well

More information

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications

More information

HCE80/HCC80/HCE80R/HCC80R

HCE80/HCC80/HCE80R/HCC80R HCE80/HCC80/HCE80R/HCC80R UNDERFLOOR HEATING-ZONEING CONTROLLERS PRODUCT DATA FEATURES Easy and fast installation because the new wiring design Pluggable terminals for fast wiring connection because clamp

More information

Documentation. M-Bus 130-mbx

Documentation. M-Bus 130-mbx Documentation M-Bus 130-mbx Introduction The mx M-Bus module is part of the mx Smart Slot communications family. With the integrated SmartSlot technology, mx systems ag offers automatic consumer data read-out

More information

CONTENTS MY HOME - VIDEO DOOR ENTRY AND HOME VIDEO SURVEILLANCE SYSTEM

CONTENTS MY HOME - VIDEO DOOR ENTRY AND HOME VIDEO SURVEILLANCE SYSTEM CTENTS MY HOME Video door entry and home video surveillance system General features...................... 34 General rules for installation.............. 36 Wiring diagrams...................... 376 MY

More information

ABB i-bus KNX Fan Coil Controller FC/S 1.1

ABB i-bus KNX Fan Coil Controller FC/S 1.1 Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation

More information

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

Section: R100 Bulletin: R100.51 Date: 07/13 Supersedes: New TRUST. Your Water Level. Steam you can depend on, 24/7. Boiler Level Indication System

Section: R100 Bulletin: R100.51 Date: 07/13 Supersedes: New TRUST. Your Water Level. Steam you can depend on, 24/7. Boiler Level Indication System Section: R100 Bulletin: R100.51 Date: 07/13 Supersedes: New TRUST Your Water Level Steam you can depend on, 24/7 Boiler Level Indication System Boiler Level Indication System Where s your water? For over

More information

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.

More information

MP-4000 Alarm List (Software version 2.4.3 or later)

MP-4000 Alarm List (Software version 2.4.3 or later) Service Bulletin SUBJECT: MP4000 Alarm s BULLETIN: C 100 DATE: June 19, 2013 ALARM LIST Where it is possible the alarm number is kept the same as for MP-3000. MP-3000 holds alarm number from 0 to 127.

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since 1997. automated production systems

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since 1997. automated production systems Alarm Systems Agri-Alert alarms have been protecting swine operations across the world since 1997. Peace of Mind The Agri-Alert alarm system constantly monitors your operation and quickly notifies you

More information

Current Monitoring Kit QUICK START GUIDE

Current Monitoring Kit QUICK START GUIDE Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...

More information

Data Sheet. Electro-mechanical counters Hengstler 800 series

Data Sheet. Electro-mechanical counters Hengstler 800 series Data Pack D Issued March 00 504897 Data Sheet Electro-mechanical counters Hengstler 800 series The 800 series totalising and predetermining batch counters, manufactured by Hengstler, is available from

More information

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

REGULINE 600VA / 1000VA REGULATOR USER MANUAL REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

SECTION 16721 FIRE ALARM AND SMOKE DETECTION SYSTEMS

SECTION 16721 FIRE ALARM AND SMOKE DETECTION SYSTEMS SECTION 16721 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Fire Alarm Control Panels B. Manual Fire Alarm Stations C. Automatic Smoke D. Fire Alarm Notification Appliances E. Auxiliary Fire Alarm Equipment

More information

Current Monitoring Kit

Current Monitoring Kit Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added

More information

T6861 Series Large LCD Digital Thermostat 110/220 VAC 2-pipe/4-pipe fan coil control

T6861 Series Large LCD Digital Thermostat 110/220 VAC 2-pipe/4-pipe fan coil control T Series arge CD Digital Thermostat 0/0 VAC -pipe/-pipe fan coil control Data sheet Application T digital thermostats are designed for application of -speed fan and s in fan coil system. Including: -pipe

More information

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC Technical Teaching Equipment Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC Teaching Technique used EDIBON SCADA System 2 Control Interface Box 5 Cables and Accessories 6 Manuals 3

More information

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner Quick Stepper 3G ECP Positioner Versions Mechanical feed-back Pneumatic Remote feed-back Local display, Pneumatic Remote feed-back Local display, Electric / Hydraulic Remote feed-back Electric / Hydraulic

More information

Aerona Air Source Heat Pumps

Aerona Air Source Heat Pumps ADDENDUM to INSTALLATION INSTRUCTIONS for Aerona Air Source Heat Pumps DOC.87-05/05 Rev.04 March 2013 ATTENTION INSTALLERS - UPDATED INFORMATION! Your Grant Aerona Air Source Heat Pump has a number of

More information

Electronically Controlled Clutchless or Variable Drive Compressors

Electronically Controlled Clutchless or Variable Drive Compressors Electronically Controlled Clutchless or Variable Drive Compressors On many new air conditioning systems, such as Lexus, Cadillac, Chrysler, and others, a new type of compressor has been fitted. There are

More information

Photovoltaic Solar Energy Unit EESFB

Photovoltaic Solar Energy Unit EESFB Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality

More information

Automatic start of a generator

Automatic start of a generator Automatic start of a generator General description This application note will help you to set your Xtender for an automatic start of a generator as per different parameters such as the output power, the

More information

Communication & Networking

Communication & Networking Overview (Actuator Sensor Interface) s MicroSmart Pentra Master Module Pg. 247 73W 145W Pg. 251 SX5A Safety Monitor Pg. 292 Flat Cable Connector SX5A Safety Communication Terminal (Safety Slave) Pg. 292

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic

More information

Wireless peripherals

Wireless peripherals Wireless peripherals EYE-02 GSM Security Camera Application note File name: EYE-02 Wireless peripherals 1/12 1 INTRODUCTION The application note describes possibilities of using camera EYE-02 with wireless

More information

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY! WARNING - SHOCK HAZARD! TO PREVENT THE POSSIBILITY OF SEVERE PERSONAL INJURY, DEATH, OR EQUIPMENT DAMAGE DUE TO ELECTRICAL

More information

Installation and operating instructions

Installation and operating instructions English Installation and operating instructions Energy meter 3-phase CETS-A via up to 1500A Description The CETS-A is a compact electronic active power energy meter for application in 3-phase power lines

More information

Neuton Solar Power Diverter Quick Installation Guide

Neuton Solar Power Diverter Quick Installation Guide Neuton Solar Power Diverter Quick Installation Guide Product Description Important Note: The NSPD is designed to operate heating elements of 3kW maximum. The Neuton Solar Power Diverter (NSPD) is designed

More information

Remote Monitoring and REC 501 Control Unit Product Guide

Remote Monitoring and REC 501 Control Unit Product Guide Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information