COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C"

Transcription

1 COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C

2 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing unit equipped with inverter driven variable speed compressor and of an indoor evaporating unit supplied together with the server-rack designed to house electronic equipment. COOLSIDE BOX is a close-loop system (direct cooling system) where the air conditioned directly flows into the server-rack. Direct cooling system COOLSIDE sucks hot air directly from the rear side of the racks, and, once cooled, enters it in the front side of the rack. COOLSIDE SERVER-RACK COOLSIDE BOX is able to dissipate thermal load from 2 up to 22kW; the modularity of the system together with the logic of adaptive microprocessor control, make this new RCGroup system the best solution for cooling of electronic equipment of new generation, characterized by high heat density. These features, together with RCGroup quality and reliability construction, make COOLSIDE BOX the system ideal for conditioning of telephone exchanges, data banks, internet hotels, server farms and all electronic architectures with high heat density. Front side INVERTER R410A E C Only cooling Twin Rotary type compressor Scroll type compressor Compressor electric motor driven by inverter R410A refrigerant charge Plug-fan with brushless type EC motor Indoor installation COOLSI

3 COOLSIDE box 3 AN EFFICIENT ENERGY USE One of the most important characteristics of coolside box units is their high energy efficiency, both at design and at the various operating conditions experienced during the year. The motocondensing units are equipped with inverter driven compressor allowing proportional control of the cooling capacity, while the axial fans electric motors are brushless type with built-in electronic commutation system (EC). The evaporating units are equipped with plug-fan directly coupled to brushless type electric motor with built-in electronic commutation system (EC). These electric motors ensuring high performances, minimum energy consumption and total absence of electromagnetic noise. Furthermore, the system close-loop that characterizes this series of machines, ensures a drastic reduction of energy losses typical of systems with cold and hot aisle, as well as the expensive infrastructure investments to achieve containment of the cold aisle. COOLSIDE BOX (R410A) Direct expansion split system with outdoor motocondensing unit coupled to indoor evaporating unit. Model M10 Cooling capacity from 2 to 10 kw Power supply 230/1/50 Motocondensing unit equipped with Twin Rotary type compressor, connected to one indoor evaporating unit Model T20 Cooling capacity from 8 to 22 kw Power supply 400/3/50+N Motocondensing unit equipped with Scroll compressor, connected to one or two indoor evaporating unit INVERTER SYSTEM The compressor driven by an inverter varies the load continuously and the regulation of the refrigerant circuit can be easily adapted, without oscillations and transients, the operating conditions required. The system is highly efficient since it is supplying the energy necessary to satisfy the required thermal load only; furthermore it is possible to supply thermal or cooling energy even in case of overload conditions of the system. The working range of coolside box, in comparison to the nominal values of cooling and thermal capacity output, varies on average from 35% to 120%. DE BOX

4 4 COOLSIDE box THE COOLSIDE BOX SYSTEM COOLSIDE COOLSIDE Indoor evaporating unit contained in the server - rack. mcai MCAI Outdoor motocondensing unit. TOTAL FLEXIBILITY The COOLSIDE BOX system is extremely modular and flexible and easily adapts to any installation requirements. The evaporating unit can be mounted either right or left of the server-rack or centrally between two server-rack. COOLSI

5 COOLSIDE box 5 NO CONSTRAINTS OF INSTALLATION The system COOLSIDE BOX can be installed in any civil environment without the need for dedicated infrastructure. EASY AND SMART INSTALLATION The air conditioning section is factory assembled, connected and charged with refrigerant gas, lubricant oil and equipped with control and protection devices. The system needs only electric and refrigerant connections. The server - rack is provided with power supply distribution system with power cables and plugs. THE SERVER RACK The server-rack is made of painted steel sheet RAL The rack is a 19 standard type (482,6 mm) - 42U (1,75 inch = 44,45 mm). The server - rack is in compliance with IEC /2 norms. Maximum load capacity for internal installation 1000 kg. The front door has a large opening angle of about 130 to allow easy access to internal components The door is made of safety glass 3 mm thick and allows direct control of the internal equipment. The back side door is made of painted steel sheet with a wide opening angle. The doors are equipped with handle with security lock 3524 E. The bus bar with maximum load of 96 A (7 modules 2 x 3 x 16A) and the power supply cord are offered as optionals. DE BOX

6 6 COOLSIDE box MAIN COMPONENTS Indoor unit SERVER RACK 19 (482,6 mm) standard rack - 42U (1,75 = 44,45 mm). BusBar for power supply distribution. Additional side rack for holding the air conditioner. Hinged panels on front and back side. Modular closure. Colour RAL EVAPORATING UNIT Plug Fan with brushless type EC motor. Washable air filter. Electronic expansion valve. R410A refrigerant charge. Refrigerant connection from the bottom. Condensate removal system. Clogged filters alarm. Air flow loss alarm. Microprocessor control. Electric panel easily accessible. Double power supply 230/1/50 (network+ups). MAIN COMPONENTS MCAI outdoor motocondensing unit MCAI M10: Twin Rotary compressor with EC type brushless motor controlled by inverter with dedicated driver. Prepared for connection to one indoor evaporating unit. MCAI T20: Scroll compressor with EC type brushless motor controlled by inverter with dedicated driver. Prepared for connection to one or two indoor evaporating units. Axial fans brushless type EC motor Refrigerant connection on back side Microprocessor control Power supply: MCAI M10: 230/1/50 - single power supply (network) MCAI T20: 400/3/50+N - double power supply (network+ups) MAIN OPTIONALS Water on floor alarm Serial port System for operation in low ambient temperature BAck side view Evaporating unit lateral view COOLSI

7 COOLSIDE box 7 MICROPROCESSOR CONTROL SYSTEM Microprocessor control system for the management and monitoring of the working and alarm statuses. The system includes: Voltage free contact for general alarm. Main components hour meter, with programmed maintenance intervention. Data logger integrated function for the events and alarms recording. Flash memory for the data storage in case of lack of power supply. Menu management with protection password. The monitoring, the programming procedure, the working status and parameter visualization, are made by the 6 keys display placed on the indoor evaporating unit. The outdoor motocondensing unit is not equipped with keyboard and display. TECHNICAL DATA AND PERFORMANCES COOLSIDE BOX M10 Indoor evaporating unit n. 1 Outdoor motocondensing Mod. M10 Cooling capacity (1) kw 2 10 COOLSIDE BOX T20 Indoor evaporating units n. 1 / 2 Outdoor motocondensing Mod. T20 Cooling capacity (1) kw 8 22 (1) Referred to entering air at 35 C with 30% rh and expansion temperature 12 C. dimensions (mm) Size a b c COOLSIDE BOX B c COOLSIDE BOX B3L a b Motocondensing a b c A B MCAI M MCAI M C DE BOX

8 C E R T I F I E D MANAGEMENT SYSTEM Technical data and dimensions are not binding. RC GROUP S.p.A. reserves the right for changes and /or modifications without notice. RC GROUP SpA Via Roma, Valle Salimbene (PV), Italy Tel Fax C_CLSBX_0112 ENGLISH RC Group S.p.A is a subsidiary of DeLclima SpA

CRAC Precision climate control units for data centres

CRAC Precision climate control units for data centres CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have

More information

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER Your Complete Turnkey Server Room Air Condition UPS THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER AVAILABLE IN WATER AND GAS SYSTEM MODEL AIR-CONDITIONED CABINET EXCELLENT TEMPERATURE CONTROL FOR

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

CoolTeg Plus Chilled Water (CW) version: AC-TCW

CoolTeg Plus Chilled Water (CW) version: AC-TCW version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420

More information

Water Chillers - The range CH and RPW series

Water Chillers - The range CH and RPW series Water Chillers - The range CH and RPW series PIOVAN S.p.A. Cooling Centre 1 (1) Piovan Chiller Range Piovan Spa 03.2004 Modification reserved Water chillers A dedicated Cooling Centre Integration with

More information

OIL-FREE ROTARY SCROLL COMPRESSOR. ECOLIFE 1,5 15 kw

OIL-FREE ROTARY SCROLL COMPRESSOR. ECOLIFE 1,5 15 kw OILFREE ROTARY SCROLL COMPRESSOR ECOLIFE 1, 1 kw EN Why The continuous innovation of the compressed air tools and machineries, the evolution of specific productive processes and uses, require exclusively

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings

More information

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,

More information

EHDC. Cooling system for Data Center and server cabinets.

EHDC. Cooling system for Data Center and server cabinets. EHDC Cooling system for Data Center and server cabinets. EHDC PEN LP EHDC L is a High Density Cooling module for an pen Loop configuration. It is ideally installed with Enoc Systems cold corridor containment

More information

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp

More information

OIL-FREE ROTARY SCROLL COMPRESSOR ECOLIFE 2 20 HP

OIL-FREE ROTARY SCROLL COMPRESSOR ECOLIFE 2 20 HP OILFREE ROTARY SCROLL COMPRESSOR ECOLIFE 0 HP EN Why The continuous innovation of the compressed air tools and machineries, the evolution of specific productive processes and uses, require exclusively

More information

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Visions become real. Temperature control and cooling systems. The innovative and reliable solution Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

In Row Cooling Options for High Density IT Applications

In Row Cooling Options for High Density IT Applications In Row Cooling Options for High Density IT Applications By Ramzi Y. Namek, PE, LEED AP, BD+C; Director of Engineering 1 Users wishing to deploy high density IT racks have several In Row Cooling solutions

More information

Rittal IT Liquid Cooling Packages

Rittal IT Liquid Cooling Packages Rittal IT Liquid Cooling Packages Higher Efficiency & Performance Optimized for Today s Data Centers R High Efficiency. High Performance. High Density. Rittal leads the industry in developing high density

More information

JAWAHARLAL NEHRU UNIVERSITY

JAWAHARLAL NEHRU UNIVERSITY School of Biotechnology JAWAHARLAL NEHRU UNIVERSITY New Delhi 110 067 Tender No. JNU/SBT/DBT-BUILDER/Data Centre/2015-16 Sealed Quotation for the establishment of a Data Centre for High-End Computational

More information

IPSIP M series-m Modular Data Center

IPSIP M series-m Modular Data Center IPSIP M series-m Modular Data Center IPSIP MODULAR TECHNOLOGIES. 1 With the rapid development of cloud computing and mobile Internet businesses, the growth of IT density and energy consumption are bringing

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and

More information

HEATER, AIR CONDITIONING AND VENTILATION

HEATER, AIR CONDITIONING AND VENTILATION 55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT

More information

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency

More information

Failure code manual. content

Failure code manual. content Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一

More information

Split units TH with hermetic compressors

Split units TH with hermetic compressors Split units TH with compressors Refrigeration units in split variant. Available with screw or solder terminal. Condensing unit with sound insulated weatherproof housing for outdoor installation. Split

More information

Packaged Air Conditioner - Water Cooled Vertical Type Model 25

Packaged Air Conditioner - Water Cooled Vertical Type Model 25 Refrigerant R407C CX Packaged Air Conditioner - Water Cooled Vertical Type Model 25 8.0kW CX 25 1 Product Code Model Power supply Product code CX 25 230V / 1 ~ / 50 Hz 7XU012153 CX 25 CX 25 2 CX 25 General

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm) UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

Low and High Static Pressure Fan Coil Units. VH2N 03 to 27. Technical Brochure. TM VH2N-A.1GB Date : June 2006 Supersedes : None

Low and High Static Pressure Fan Coil Units. VH2N 03 to 27. Technical Brochure. TM VH2N-A.1GB Date : June 2006 Supersedes : None Low and High Static Pressure Fan Coil Units VH2N 03 to 27 Technical Brochure TM VH2N-A.1GB Date : June 2006 Supersedes : None Design Features Presentation The VH2N fan coil units has been specially designed

More information

Daikin Altherma hybrid heat pump. The natural combination

Daikin Altherma hybrid heat pump. The natural combination Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient

More information

30-120 3 Phase Modular Finally the benefits of Modular ups are for all

30-120 3 Phase Modular Finally the benefits of Modular ups are for all MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion

More information

RPV - RP - RA air handling units

RPV - RP - RA air handling units APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW - AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness

More information

Air handling unit. REC Temovex 250S-EC-RS. Experts on indoor climate in low-energy houses

Air handling unit. REC Temovex 250S-EC-RS. Experts on indoor climate in low-energy houses REC Temovex 25S-EC-RS Experts on indoor climate in low-energy houses RT 25S-EC-RS REC Temovex 25S-EC-RS Made in Sweden ECO2 control system for low-energy and passive houses Comprises: - Air flow boost

More information

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors European Refrigeration Controls Catalogue Catalogue Section 4 Product Bulletin P215PR/RM Issue 01/03/2013 Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for

More information

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity Liebert Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment Precision Cooling For Business-Critical Continuity The Intelligent Data Center Cooling Solution: Liebert Trust the industry

More information

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses REC Temovex 4S-EC-RS Experts on indoor climate in low-energy houses RT 4S-EC-RS REC Temovex 4S-EC-RS Made in Sweden ECO2 control system for low-energy and passive houses Comprises: - Air flow boost for

More information

SECTION 11 78 13 MORTUARY REFRIGERATORS

SECTION 11 78 13 MORTUARY REFRIGERATORS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in

More information

POWER USAGE EFFECTIVENESS. Developing Best Practices Manual for Indian Data Centers. Presentation by HVAC Core Group

POWER USAGE EFFECTIVENESS. Developing Best Practices Manual for Indian Data Centers. Presentation by HVAC Core Group POWER USAGE EFFECTIVENESS Developing Best Practices Manual for Indian Data Centers PUE - Power usage effectiveness is Total incoming power( IT equipment + electrical And mechanical support system ) / Presentation

More information

Chilled Water Precision Air Conditioner For Critical Application

Chilled Water Precision Air Conditioner For Critical Application AIRSYS-P-SC-OPTIMA-HD-E1304V01.2 HD Chilled Water Precision Air Conditioner For Critical Application Cooling capacity: 42.1kW~161.5kW OPTIMA product family is designed for medium to large data center.

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS

More information

Cool Design for Homes and Offices

Cool Design for Homes and Offices AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive, and designed to fit any space: there are Cool Design for Homes and Offices a lot of reasons why Air Blue air conditioners

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

ThermoStar Refrigeration Air Dryers

ThermoStar Refrigeration Air Dryers ThermoStar Refrigeration Air Dryers Why dry compressed air? Contamination Reduces Efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. These problems

More information

Appendix - Controllers 179

Appendix - Controllers 179 Version: 200703 Appendix - Controllers 179 -3- -4- -5- -6- -7- -8- 2. Specifications 2.1 Specifications for inverter units item Model AB182ACERA Function cooling heating Capacity kw 5.01.8--5.8 5.22.0---6.2

More information

Refrigerant R410A. Mini SysAqua DCI. 5.5 to 16.0kW. Air-to-Water DCI Heat Pumps Models M.AQA05 DCI to M.AQA16 DCI

Refrigerant R410A. Mini SysAqua DCI. 5.5 to 16.0kW. Air-to-Water DCI Heat Pumps Models M.AQA05 DCI to M.AQA16 DCI Refrigerant R4A Mini SysAqua DCI Air-to-Water DCI Heat Pumps Models M.AQA05 DCI to M.AQA16 DCI 5.5 to 16.0kW Mini SysAqua DCI 1 Strength Points By introducing the variable speed in our packaged heat pump

More information

OIL SEPARATORS. 112

OIL SEPARATORS. 112 OIL SEPARATORS 111 OIL SEPARATORS APPLICATIONS The oil separators, shown in this chapter, are classified Pressure vessels in the sense of the Pressure Equipment Directive 97/23/EC, Article 1, Section 2.1.1

More information

TopTherm Blue e Wall-Mounted Cooling Units UL Type 3R

TopTherm Blue e Wall-Mounted Cooling Units UL Type 3R TopTherm Blue e Wall-Mounted Cooling Units UL Type 3R Blue e UL Type 3R The climate control solution for enclosures exposed to the great outdoors. Heat can damage equipment inside an enclosure and lead

More information

White Paper Rack climate control in data centres

White Paper Rack climate control in data centres White Paper Rack climate control in data centres Contents Contents...2 List of illustrations... 3 Executive summary...4 Introduction...5 Objectives and requirements...6 Room climate control with the CRAC

More information

Air Conditioners for Cabinets

Air Conditioners for Cabinets PREDATOR EVOLUTION Air Conditioners for Cabinets STULZ with Predator Evolution line offers you a complete range of professional air conditioners for telecom shelters and other enclosures. Predator Evolution

More information

APC APPLICATION NOTE #112

APC APPLICATION NOTE #112 #112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.

More information

IT-SOLUTIONS.

IT-SOLUTIONS. IT-SOLUTIONS Well conceived Haewa Group has gained a strong profile as an innovative and competent supplier for the machinery, systems, electrical and electronic industries, well beyond European geographic

More information

Freezers - Ultrafreezers. Platilab & Irilab Series

Freezers - Ultrafreezers. Platilab & Irilab Series Freezers - Ultrafreezers Platilab & Irilab Series PLATILAB: top security and performances with reliable temperature control. IRILAB: combining the high reliability of PLATILAB with the possibility to store

More information

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER

More information

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6. TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM

More information

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ SERVICE MANUAL Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ FS2MI-147HFD FS2MI-187HFD FS3MI-217HFD FS3MI-277HFD FS4MI-277HFD FS4MI-367HFD FS5MI-367HFD NOTE: Before servicing the

More information

Choosing Close-Coupled IT Cooling Solutions

Choosing Close-Coupled IT Cooling Solutions W H I T E P A P E R Choosing Close-Coupled IT Cooling Solutions Smart Strategies for Small to Mid-Size Data Centers Executive Summary As high-density IT equipment becomes the new normal, the amount of

More information

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability PFD-P250VM-E PUHY-P250YJM-A(-BS) PUHY-P500YSJM-A(-BS) PQHY-P250YHM-A CLOSE CONTROL SYSTEM MITSUBISHI ELECTRIC s Close Control System (PFD series) is specifically designed for computer rooms, laboratories

More information

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled

More information

IV. Rear Mount System

IV. Rear Mount System Mobile Climate Control 45 MCC Reference Manual 2014 PN: 89-3069 Rearmount Air Conditioning System Eco RM Capacity, Reliability, and Serviceability MCC Eco RM unit, selected as preferred equipment by leading

More information

RiMatrix S Make easy.

RiMatrix S Make easy. RiMatrix S Make easy. 2 RiMatrix S Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power

More information

FULL DC INVERTER SYSTEMS

FULL DC INVERTER SYSTEMS FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation

More information

Kälte Klima. Condenserless chillers for indoor installation from 45 kw to 360 kw. Scroll compressors SCLY DE 48

Kälte Klima. Condenserless chillers for indoor installation from 45 kw to 360 kw. Scroll compressors SCLY DE 48 Condenserless chillers for indoor installation from 45 kw to 360 kw Scroll compressors Series: SCLY Leaflet: DE 48 Issue: 03/12 Supersedes: 04/11 Index Identification code Index... pag. 2 Identification

More information

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment The Intelligent Data Center Cooling Solution: Liebert CRV Trust the industry leader in Precision Cooling to deliver

More information

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED. Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED. Presentation Goals & Outline Power Density Where we have been- where we are now - where we are going Limitations of Air Cooling

More information

Huawei IDS2000 Modular Data Center Solution

Huawei IDS2000 Modular Data Center Solution CloudPower Huawei IDS2000 Modular Data Center Solution HUAWEI TECHNOLOGIES CO., LTD. With the rapid development of cloud computing and mobile Internet businesses, the growth of IT density and energy consumption

More information

Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed

Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Rely on GD to provide the perfect fit The perfect fit to maximise productivity The growing industrial demand for compressed air requires

More information

Thermal Protection for Critical Electronics

Thermal Protection for Critical Electronics ELECTRO-TECHNOLOGY OR INDUSTRY Cooling Units Thermal Protection for Critical Electronics DTS 3000, DTT 6000 and DTI 6000 Series Cooling Units Utilize closed loop cooling in tough industrial or outdoor

More information

News in Data Center Cooling

News in Data Center Cooling News in Data Center Cooling Wednesday, 8th May 2013, 16:00h Benjamin Petschke, Director Export - Products Stulz GmbH News in Data Center Cooling Almost any News in Data Center Cooling is about increase

More information

SERVER ROOM CABINET INSTALLATION CONCEPTS

SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS ZPAS 169 EXAMPLES OF SERVER ROOMS PROJECTS WITH ZPAS CABINETS Data Box in the

More information

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System Auxiliary HVAC RAM ProMaster Standard Tie-in Extreme Climate System Auxiliary HVAC High performance aftermarket heating and cooling systems engineered for vehicle specific platforms that minimize install

More information

Elements of Energy Efficiency in Data Centre Cooling Architecture

Elements of Energy Efficiency in Data Centre Cooling Architecture Elements of Energy Efficiency in Data Centre Cooling Architecture Energy Efficient Data Center Cooling 1 STULZ Group of Companies Turnover 2006 Plastics Technology 400 Mio A/C Technology 200 Mio Total

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw Knürr DCL Modular Rack Cooling from 6 kw to 60 kw Emerson Network Power Business-Critical Continuity so your success continues! Core competencies AC Power Connectivity DC Power Embedded Computing Embedded

More information

ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products

ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products ECM Motors Manufactured By Regal Beloit Products and Applications- What s an ECM? ECM 2.3 series ECM 142 Arktic ECM 58mm Arktic ECM 59 Arktic SSC2 Arktic 51 GEXPRO Regal Beloit s distribution arm for all

More information

2 Rittal Micro Data Centre

2 Rittal Micro Data Centre Micro Data Centre 2 Rittal Micro Data Centre The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power distribution,

More information

Monozone/Multizone. Outdoor Unit. Wall Mounted. In the Ceiling. Floor Mounted 60cm x 60cm Cassette

Monozone/Multizone. Outdoor Unit. Wall Mounted. In the Ceiling. Floor Mounted 60cm x 60cm Cassette Comprehensive range/long pipe length and easy installation You can choose and connect freely from different types of indoor and outdoor units depending on the number of rooms, width and shape of the room.

More information

Energy efficient data centre cooling. InRack Cooling & The Intelligent Cooling System. aircold.dk

Energy efficient data centre cooling. InRack Cooling & The Intelligent Cooling System. aircold.dk Energy efficient data centre cooling InRack Cooling & The Intelligent Cooling System aircold.dk 2 3 350 days of free cooling will put you in tears of joy Contents Aircold is a Danish engineering and cooling

More information

Why Daikin? 2015 Houston, Texas USA www.daikincomfort.com

Why Daikin? 2015 Houston, Texas USA www.daikincomfort.com Why Daikin? Daikin: The Premium Brand industry leader Daikin is recognized as the world s number one leader in the manufacture of HVAC equipment and refrigerants. For over 90 years, Daikin has grown consistently

More information

Natural geothermal energy.

Natural geothermal energy. ROTEX ground source heat pump Natural geothermal energy. ROTEX HPU ground the ground source heat pump that heats with free geothermal energy. Compact, environmentally responsible and uniquely efficient.

More information

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS NOR-LAKE, INCORPORATED 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-4291 FAX www.norlake.com Split-Pak Pre-Assembled

More information

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III.1. Large Roof Mount PN: 89-3037 Roof Mount Unit Eco 136 Parallel roof mount Air-conditioning and ventilation systems The Eco 136

More information

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015 I-STUTE Project - WP2.3 Data Centre Cooling Project Review Meeting 8, Loughborough University, 29 th June 2015 Topics to be considered 1. Progress on project tasks 2. Development of data centre test facility

More information

ARMSTRONG AIR HEAT PUMPS www.armstrongair.com

ARMSTRONG AIR HEAT PUMPS www.armstrongair.com INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7

More information

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER

More information

Refrigeration Air Dryers. Catalogue

Refrigeration Air Dryers. Catalogue Refrigeration Air Dryers Catalogue GB Using a dryer is worth it Humidity is a component of atmospheric air, which can be found in our compressed air distribution systems and the machines that use the compressed

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while

More information

AUTOMOTIVE AIR CONDITIONING SYSTEM.

AUTOMOTIVE AIR CONDITIONING SYSTEM. . 104 105 106 107 Assembly and Disassembly of Automatic Air Condition 104 Automatic Air Condition System with Automatic LabView System Automatic Air Condition System with Fault Insertion Panel Cut away

More information

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES

More information

KONRAD. Hybrid Fancoil Series

KONRAD. Hybrid Fancoil Series KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks

More information

Daikin Altherma. hybrid heat pump. The natural combination

Daikin Altherma. hybrid heat pump. The natural combination Daikin Altherma hybrid heat pump The natural combination Why choose Daikin? As an industry leader, Daikin combines broad experience, technical innovation and responsive customer service to help you meet

More information

AIR-CONDITIONER SPLIT TYPE

AIR-CONDITIONER SPLIT TYPE FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,

More information

01 GB. Refrigeration Dryer. High quality compressed air. F-Series. Energy efficient compressed air treatment. 50Hz & 60Hz

01 GB. Refrigeration Dryer. High quality compressed air. F-Series. Energy efficient compressed air treatment. 50Hz & 60Hz 01 GB Refrigeration Dryer High quality compressed air Energy efficient compressed air treatment F-Series 50Hz & 60Hz Energy efficient refrigeration dryers First-class air treatment efficiency For CompAir,

More information

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description Description Compact air/water heat pump for outside installation. With suction gas cooled rotary compressor. With extensive aluminium/cu lamellar tube evaporator and PVC Titanium condenser. Axial fan Refrigerant

More information

State of the Art Energy Efficient Data Centre Air Conditioning

State of the Art Energy Efficient Data Centre Air Conditioning - White Paper - State of the Art Energy Efficient Data Centre Air Conditioning - Dynamic Free Cooling - Release 2, April 2008 Contents ABSTRACT... 3 1. WHY DO I NEED AN ENERGY EFFICIENT COOLING SYSTEM...

More information

w soundproof wall box. Superior sound attenuation wall boxes With cooling ability up to 1.5kW. Product overview and technical data

w soundproof wall box. Superior sound attenuation wall boxes With cooling ability up to 1.5kW. Product overview and technical data 7250 700w soundproof wall box Superior sound attenuation wall boxes With cooling ability up to 1.5kW Product overview and technical data O v e r v i e w 7250-SP 700 wide sound proof wall box As many office

More information