SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z ALLTITE, INC Murdock, Wichita, KS Bruce Demaree Phone:
|
|
- Albert Norman
- 7 years ago
- Views:
Transcription
1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z ALLTITE, INC Murdock, Wichita, KS Bruce Demaree Phone: CALIBRATION Valid To: September 30, 2016 Certificate Number: In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following calibrations 1 : I. Electrical DC/Low Frequency Parameter/Equipment Range CMC 2 (±) Comments DC Voltage Generate 3 (0 to 320) mv (0.32 to 3.2) V (3.2 to 32) V (32 to 320) V (320 to 1050) V mv V V V 0.14 V DC Current Generate 3 (0 to 320) µa 320 µa to 3.2 ma (3.2 to 32) ma (32 to 320) ma 320 ma to 3.2 A (3.2 to 10.5) A µa 0.53 µa ma 0.06 ma 2.2 ma 12 ma Resistance Generate 3 (0 to 40) Ω (40 to 400) Ω (400 to 4000) Ω (40 to 400) kω (400 to 4000) kω (4 to 40) MΩ (40 to 400) MΩ 0.33 Ω 0.37 Ω 0.79 Ω 120 Ω 7.7 kω 330 kω 1.4 MΩ (A2LA Cert. No ) 10/09/2014 Page 1 of 6
2 Parameter/Range Frequency CMC 2 (±) Comments AC Voltage Generate 3 (0 to 10) mv AC 0.45 mv 0.61 mv 1.1 mv 2.2 mv 5.9 mv (10 to 32) mv AC 0.39 mv 0.2 mv 0.48 mv 0.7 mv 1.6 mv (32 to 320) mv AC 0.32 mv 0.51 mv 0.6 mv 0.9 mv 2.2 mv 320 mv AC to 3.2 V AC 3.8 mv 89 mv 95 mv 21 mv 59 mv (3.2 to 32) V AC 0.12 V V V 0.16 V 0.46 V (32 to 105) V AC 0.15 V 0.22 V 0.28 V 0.33 V (105 to 320) V AC (40 to 100) Hz 100 Hz to 1 khz (1 to 3) khz 2.6 V 1.3 V 1.4 V (A2LA Cert. No ) 10/09/2014 Page 2 of 6
3 Parameter/Range Frequency CMC 2 (±) Comments AC Voltage Generate (cont) (320 to 800) V AC (40 to 100) Hz 100 Hz to 1 khz (1 to 3) khz 4.8 V 3 V 3.1 V 3.1 V (800 to 1050) V AC (40 to 100) Hz 100 Hz to 1 khz (1 to 3) khz 6.2 V 4 V 4 V 4.1 V AC Current Generate 3 (0 to 32) µa AC 1.2 µa 3.5 µa 13 µa 27 µa (32 to 320) µa AC 1.3 µa 3.3 µa 12 µa 25 µa 320 µa to 320 ma AC 0.56 ma 1.1 ma 1.7 ma 2.5 ma 320 ma to 3.2 A AC 5.8 ma 48 ma (3.2 to 10.5) A AC 41 ma 0.15 A (10.5 to 20) A AC A 0.39 A (0 to 20) A AC (100 to 440) Hz 0.37 A 0.53 A w/ 10 turn (20 to 100) A AC (10 to 100) Hz (100 to 440) Hz 0.72 A 1.5 A w/ 10 turn (100 to 150) A AC (10 to 100) Hz 0.8 A w/ 50 turn (A2LA Cert. No ) 10/09/2014 Page 3 of 6
4 Parameter/Range Frequency CMC 2 (±) Comments AC Current Generate (cont) (150 to 1000) A AC (10 to 100) Hz 4.2 A w/ 50 turn II. Mechanical Parameter/Equipment Range CMC 2 (±) Comments Torque Manual Torque Wrenches 3 (2 to 20) in lbf (20 to 200) in lbf ft lbf ISO 6789:2003 Manually applied and measured with a transducer (50 to 500) ft lbf ft lbf (500 to 2000) ft lbf 1.9 ft lbf Hydraulic Torque Wrenches 3 (500 to 5000) ft lbf (2000 to ) ft lbf 9 ft lbf ft lbf Hydraulic pressure measured and compared to torque measured by transducers ( to ) ft lbf 43 ft lbf (A2LA Cert. No ) 10/09/2014 Page 4 of 6
5 Parameter/Equipment Range CMC 2 (±) Comments Pneumatic Torque Gun 3 (0 to 5000) ft lbf 3.2 ft lbf Pneumatic pressure set and torque measured with transducer Electronic Torque Gun 3 (0 to 5000) ft lbf 3.2 ft lbf Digital torque set and torque measured with torque transducers Torque Multiplier 3 (0 to 2000) ft lbf (output) 14 ft lbf Input and output torque measured with torque transducers Torque Transducers (2 to 2000) ft lbf 0.28 ft lbf % ft lbf Torque arm with weights (1000 to ) ft lbf 4.6 ft lbf % ft lbf Pressure 3 Hydraulic Gauges (0 to 300) psig (300 to 3000) psig 0.19 psig psig Comparison with standard hydraulic pressure gage (3001 to ) psig 4.8 psig + 32 ( to ) psig 60 psig III. Time & Frequency Parameter/Equipment Range CMC 2 (±) Comments Frequency Measuring 0.5 Hz to 10.0 MHz 5.8 khz Equipment 3 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement (A2LA Cert. No ) 10/09/2014 Page 5 of 6
6 that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration and this laboratory meets A2LA R104 General Requirements: Accreditation of Field Testing and Field Calibration Laboratories for these calibrations. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer s site being larger than the CMC. (A2LA Cert. No ) 10/09/2014 Page 6 of 6
7 A2LA has accredited ALLTITE, INC Wichita, KS for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This laboratory also meets the requirements of ANSI/NCSL Z and any additional program requirements in the field of calibration. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Presented this 9 th day of October President & CEO For the Accreditation Council Certificate Number Valid to September 30, 2016 For the calibrations to which this accreditation applies, please refer to the laboratory s Calibration Scope of Accreditation.
3M CORPORATE METROLOGY SERVICES St. Paul, MN
A2LA has accredited THE AMERICAN ASSOCIATION FOR LABORATORY ACCREDITATION ACCREDITED LABORATORY 3M CORPORATE METROLOGY SERVICES St. Paul, MN for technical competence in the field of Calibration This laboratory
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z540-1-1994
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z540-1-1994 TEKTRONIX, INC. 13725 SW Karl Braun Drive Beaverton, OR 97077 Andrew Mumford Phone: 503 627 2476 CALIBRATION Valid to: June 30, 2018
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 F. D. HURKA COMPANY 4731 Stockholm Court Charlotte, NC 28273 Paul Yanney Phone: 704 552 0008 CALIBRATION Valid To: December 31, 2016
More informationAccredited Laboratory
Accredited Laboratory A2LA has accredited CORPORATE CONSULTING SERVICE & INSTRUMENTS INC. Akron, OH for technical competence in the field of Calibration This laboratory is accredited in accordance with
More informationPROMPT ENGINEERING & TRADING SERVICES CO. W.L.L P.O. BOX 24067 BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR
This is to signify that PROMPT ENGINEERING & TRADING SERVICES CO. W.L.L P.O. BOX 24067 BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR Calibration Laboratory CL-165 has met the requirements
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. 393.00 Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc., has assessed the Laboratory of: (Hereinafter called the Organization) and
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Old Bracknell Lane West Bracknell Berkshire RG12 7AH Contact: Mr M Trotter Tel: +44 (0)1344 459314 Fax: +44 (0)1344 465556 E-Mail: mtrotter@bis.fm
More informationMUHAMMAD ABDULLAH AL-AZZAZ COMPANY LIMITED P.O. BOX 31172 AL-KHOBAR 31952 KINGDOM OF SAUDI ARABIA
This is to signify that MUHAMMAD ABDULLAH AL-AZZAZ COMPANY LIMITED P.O. BOX 31172 AL-KHOBAR 31952 KINGDOM OF SAUDI ARABIA Calibration Laboratory CL-151 has met the requirements of the IAS Accreditation
More informationipimms is an industry primary impedance measurement service supplied and maintained by UK s National Physical Laboratory. [4]
Page: 1 of 25 LABORATORY LOCATION: (PERMANENT LABORATORY) AGILENT TECHNOLOGIES MICROWAVE PRODUCTS (M) SDN. BHD. BAYAN LEPAS FREE INDUSTRIAL ZONE 11900 PENANG, MALAYSIA This laboratory accredited under
More informationScope of accreditation SP Technical Research Institute, Department of Calibration and Verification, Borås - 1002
2015-12-11 2014/2779 Technical Research Institute, Department of Calibration and Verification, Borås - 1002 Accredited calibration activities are conducted at the following laboratories: Box 56 SE-230
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK
code Location code Customers Sites locations: 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK Calibration Centre Bolkiah Garrison BB3510 Negara Brunei Darussalam Contact: Mr Lim Tiong Thai Tel: +673-2-386475
More informationSCS Directory Accreditation number: SCS 0115
International standard: ISO/IEC 17025:2005 Swiss standard: SN EN ISO/IEC 17025:2005 METRON SA Calibration Laboratory Via Luserte Sud 7 CH-6572 Quartino Head: Angelo Capone Responsible for MS: Angelo Capone
More informationPIN CONFIGURATION FEATURES ORDERING INFORMATION ABSOLUTE MAXIMUM RATINGS. D, F, N Packages
DESCRIPTION The µa71 is a high performance operational amplifier with high open-loop gain, internal compensation, high common mode range and exceptional temperature stability. The µa71 is short-circuit-protected
More informationINyMET SALVATIERRA NO. 32-5 COL SAN BARTOLO ATEPEHUACAN D.F. 07730 MEXICO
This is to signify that INyMET SALVATIERRA NO. 32-5 COL SAN BARTOLO ATEPEHUACAN D.F. 07730 MEXICO Calibration Laboratory CL-101 has met the requirements of the IAS Accreditation Criteria for Calibration
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Unit 7 Contact: Mr S C Sparks Solent Industrial Estate Tel: +44 (0)1489 790296 Hedge End Fax: +44 (0)1489 790294 Southampton E-Mail: info@southcal.co.uk
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 MGA RESEARCH CORPORATION 820 Suburban Park Drive Greer, SC 29651 Jennifer Young Phone: (864) 848-3088 Website: www.mgaresearch.com MECHANICAL Valid Until: May
More informationIsolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give
More informationElectricity and Magnetism, Georgia, GEOSTM (Georgian National Agency for Standards and Metrology)
single references 1 1.018 V Temperature (23 ± 3) C 6 µv 2 95% No 1 single references 10 10 V Temperature (23 ± 3) C 25 µv 2 95% No 2 low ranges DMM > 0.01 10 V Temperature (23 ± 3) C 2E-06U + 3E-06 to
More informationMeasuring Insulation Resistance of Capacitors
Application Note Measuring Insulation Resistance of Capacitors A common use of high resistance measuring instruments (often called megohmmeters or insulation resistance testers) is measuring the insulation
More informationIAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS
REFERENCES NIST Special Publication 330 IAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS Revised October 2013 International vocabulary of metrology Basic and general concepts and
More informationDS 600. A contact free flux gate based current measurement sensor 600A rms
DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum
More information1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.
1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter
More informationINTEGRATED CIRCUITS DATA SHEET. TDA7000 FM radio circuit. Product specification File under Integrated Circuits, IC01
INTEGRATED CIRCUITS DATA SHEET File under Integrated Circuits, IC01 May 1992 GENERAL DESCRIPTION The is a monolithic integrated circuit for mono FM portable radios, where a minimum on peripheral components
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 YANFENG AUTOMOTIVE TRIM SYSTEMS CO. LTD. China Technical Center No. 1001 North Qinzhou Rd. Shanghai, China 200233 Shao Xiong (Test Center Manager/Local Authorized
More informationObjective. To design and simulate a cascode amplifier circuit using bipolar transistors.
ascode Amplifier Design. Objective. o design and simulate a cascode amplifier circuit using bipolar transistors. Assignment description he cascode amplifier utilises the advantage of the common-emitter
More informationHA-5104/883. Low Noise, High Performance, Quad Operational Amplifier. Features. Description. Applications. Ordering Information. Pinout.
HA5104/883 April 2002 Features This Circuit is Processed in Accordance to MILSTD 883 and is Fully Conformant Under the Provisions of Paragraph 1.2.1. Low Input Noise Voltage Density at 1kHz. 6nV/ Hz (Max)
More informationTorque Transducers MEASURING ELECTRONIC
Screwdriving technology Automation Air motors Air tools MEASURING ELECTRONIC Torque Transducers In most situations, the essential element of screwdriving technology is torque. Controlling the torque generated
More informationLM741. Single Operational Amplifier. Features. Description. Internal Block Diagram. www.fairchildsemi.com
Single Operational Amplifier www.fairchildsemi.com Features Short circuit protection Excellent temperature stability Internal frequency compensation High Input voltage range Null of offset Description
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1 BUREAU VERITAS ADT (SHANGHAI) CORPORATION 2F, Building C, No. 1618. Yishan Road 201103 Shanghai, CHINA Ms. Mary Gu (Authorized Representative) Phone: 86 21
More informationcss Custom Silicon Solutions, Inc.
css Custom Silicon Solutions, Inc. CSS555(C) CSS555/ PART DESCRIPTION The CSS555 is a micro-power version of the popular 555 Timer IC. It is pin-for-pin compatible with the standard 555 timer and features
More informationWahl C50 Calibrator FEATURES
NEW! On Site Multifunction Portable Far Superior Accuracy as Compared to Fluke! Simultaneous Measurement and Generation Quick Connect Terminals Anti-Shock Boot Quick Connect Terminals Navigator Power Supply,
More informationDigital Pressure Measuring Instrument MDR480
Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm
More informationOp Amp Circuit Collection
Op Amp Circuit Collection Note: National Semiconductor recommends replacing 2N2920 and 2N3728 matched pairs with LM394 in all application circuits. Section 1 Basic Circuits Inverting Amplifier Difference
More informationEco Green Labs India Pvt. Ltd., Ground Floor, Plot No. 100, New Sidco Industrial Estate, Srinagar, Hosur, Tamil Nadu
Last Amended on - Page 1 of 5 I. DIMENSION $ 1. PLAIN PLUG S Upto Ø 100 mm 1.1 m Using ULM > Ø100 mm to Ø 300 mm 2.4 m 2. PLAIN RING S Upto Ø 100 mm 1.7 m Using ULM >Ø100 mm to Ø 300 mm 3.6 m 3. THREAD
More informationFREJA 300 Relay Testing System
Relay Testing System A Megger Group Company FREJA 300 Relay testing system The FREJA 300 relay testing system is a computer-aided relay testing and simulation system. The weight of FREJA 300 is only 15
More informationUser's Guide. True RMS Industrial Multimeter
User's Guide 97650 True RMS Industrial Multimeter Ω C ã F ã 10A V µ 10A V ã ã ma A Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),
More informationCalibration of Electronic Test Equipment: An Introduction to ISO 17025 & Accreditation
Calibration of Electronic Test Equipment: An Introduction to ISO 17025 & Accreditation Presentation s Objectives What does Calibration mean? What is ISO 17025, what is Accreditation, and what is the difference?
More informationPRODUCT PROFILE FEATURES
PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER
More informationTHERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
More information4N25 Phototransistor Optocoupler General Purpose Type
4N Phototransistor Optocoupler General Purpose Type Data Sheet Lead (Pb) Free RoHS 6 fully compliant RoHS 6 fully compliant options available; -xxxe denotes a lead-free product Description The 4N is an
More informationPosition Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN
More informationCALIBRATION PRINCIPLES
1 CALIBRATION PRINCIPLES After completing this chapter, you should be able to: Define key terms relating to calibration and interpret the meaning of each. Understand traceability requirements and how they
More informationOptocoupler, Phototransistor Output, with Base Connection
4N25, 4N26, 4N27, 4N28 Optocoupler, Phototransistor Output, FEATURES A 6 B Isolation test voltage 5000 V RMS Interfaces with common logic families C 2 5 C Input-output coupling capacitance < pf NC 3 4
More informationOPERATIONAL AMPLIFIERS. o/p
OPERATIONAL AMPLIFIERS 1. If the input to the circuit of figure is a sine wave the output will be i/p o/p a. A half wave rectified sine wave b. A fullwave rectified sine wave c. A triangular wave d. A
More informationSignal Conditioning Amplifier System
Micro-Measurements A2 FEATURES Strain gage, transducer, and thermocouple inputs Frequency response to 110 khz Analog output of ±10 VDC Operation with 12 to 15 VDC and 120/240 VAC power Scalable from 8
More informationReading: HH Sections 4.11 4.13, 4.19 4.20 (pgs. 189-212, 222 224)
6 OP AMPS II 6 Op Amps II In the previous lab, you explored several applications of op amps. In this exercise, you will look at some of their limitations. You will also examine the op amp integrator and
More informationSupertex inc. HV256. 32-Channel High Voltage Amplifier Array HV256. Features. General Description. Applications. Typical Application Circuit
32-Channel High Voltage Amplifier Array Features 32 independent high voltage amplifiers 3V operating voltage 295V output voltage 2.2V/µs typical output slew rate Adjustable output current source limit
More informationCentro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
More informationAuto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL
Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL WARNING: READ AND UNDERSTAND THIS MANUAL BEFORE USING YOUR MULTIMETER. FAILURE TO UNDERSTAND AND COMPLY WITH WARNINGS AND OPERATING INSTRUCTIONS
More informationNTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter
NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter Description: The NTE2053 is a CMOS 8 bit successive approximation Analog to Digital converter in a 20 Lead DIP type package which uses a differential
More informationPowerAmp Design. PowerAmp Design PAD135 COMPACT HIGH VOLATGE OP AMP
PowerAmp Design COMPACT HIGH VOLTAGE OP AMP Rev G KEY FEATURES LOW COST SMALL SIZE 40mm SQUARE HIGH VOLTAGE 200 VOLTS HIGH OUTPUT CURRENT 10A PEAK 40 WATT DISSIPATION CAPABILITY 200V/µS SLEW RATE APPLICATIONS
More information3466 Building Energy Management Training Systems
3466 Building Energy Management Training Systems LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 06/2015 Table of Contents General Description 3 Courseware 3 Topic Coverage 4 List of Available
More informationMCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description
Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V
More informationMulti-Range Programmable DC Power Supplies 9115 Series
Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional
More information2002 IS Catalog. Page
00 IS Catalog Page Introduction... 47 Transmitter (8 V entity parameter) KFD-CR-Ex1.30.00 (-wire transmitter)... 48 KFD-CR-Ex1.30.300 (- or 3-wire transmitter)... 49 KFD-CR-Ex1.30.300 90C (- or 3-wire,
More informationMODEL IFMA - DIN-RAIL FREQUENCY TO ANALOG CONVERTER
Bulletin No. IFMA-E Drawing No. LP0340 Released 5/06 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL IFMA - DIN-RAIL FREQUENCY TO ANALOG CONVERTER SIMPLE ON-LINE RANGE SETTING (Using
More informationLoop Calibration and Maintenance
Loop Calibration and Maintenance Application Note Introduction Process instrumentation requires periodic calibration and maintenance to ensure that it is operating correctly. This application note contains
More information3522-50/3532-50 LCR HiTESTER Components measuring instruments
Improved with Faster Measurement! 3522-50/3532-50 LCR HiTESTER Components measuring instruments 2001 Improved 3522-50 / 3532-50 further shortens line tact time with its high-speed measuring power High
More informationJUMPFLEX 857 Series. 0...20 ma 2...10 V. 4...20 ma. Transducers / Relay and Optocoupler Modules
0888-0172/0002-3601 JUMPFLEX 857 Series 2.0 E 12/08 Printed in Germany Subject to design changes 2...10 V 0...20 ma 4...20 ma WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 32385 Minden Hansastraße 27
More informationLABORATORY 2 THE DIFFERENTIAL AMPLIFIER
LABORATORY 2 THE DIFFERENTIAL AMPLIFIER OBJECTIVES 1. To understand how to amplify weak (small) signals in the presence of noise. 1. To understand how a differential amplifier rejects noise and common
More informationLoad Cell Troubleshooting
VPG TRANSDUCERS Load Cells and Weigh Modules Technical Note VPGT-08 Scope Load cells are designed to sense force or weight under a wide range of adverse conditions; they are not only the most essential
More informationLow Noise, Matched Dual PNP Transistor MAT03
a FEATURES Dual Matched PNP Transistor Low Offset Voltage: 100 V Max Low Noise: 1 nv/ Hz @ 1 khz Max High Gain: 100 Min High Gain Bandwidth: 190 MHz Typ Tight Gain Matching: 3% Max Excellent Logarithmic
More informationElectricity & Electronics 5: Alternating Current and Voltage
Electricity & Electronics 5: lternating Current and Voltage lternating Current and Voltage IM This unit looks at several aspects of alternating current and voltage including measurement of frequency and
More informationT-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
More information10 Multimeter. Users Manual
10 Multimeter Users Manual 1991-2001 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks of their respective companies. 10 MULTIMETER m m Mk SELECT RANGE OFF VDC VAC
More information0.9V Boost Driver PR4403 for White LEDs in Solar Lamps
0.9 Boost Driver for White LEDs in Solar Lamps The is a single cell step-up converter for white LEDs operating from a single rechargeable cell of 1.2 supply voltage down to less than 0.9. An adjustable
More informationHSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
More informationOptocoupler, Phototransistor Output, with Base Connection
Optocoupler, Phototransistor Output, with Base Connection FEATURES i794-4 DESCRIPTION This datasheet presents five families of Vishay industry standard single channel phototransistor couplers. These families
More informationDigital Ground Resistance Tester. Models 4620 & 4630. Digital Ground Resistance Tester
Digital Ground Resistance Tester Models 4620 & 4630 Digital Ground Resistance Tester Models 4620 and 4630 perform both ground resistance and soil resistivity tests. These testers measure from 0 to 2000Ω,
More informationISO/IEC 17025 ACCREDITATION REQUIREMENTS FOR CALIBRATION LABORATORIES
ISO/IEC 17025 ACCREDITATION REQUIREMENTS FOR CALIBRATION LABORATORIES AUTHORITY: VICE PRESIDENT EFFECTIVE DATE: 2015/01/01 DOCUMENT NUMBER: MA 2002 TABLE OF CONTENTS Foreword... 3 1. Application... 4 2.
More informationENERGY STAR Program Requirements Product Specification for Data Center Storage. Draft 2 Test Method March 2013
ENERGY STAR Program Requirements Product Specification for Data Center Storage Draft 2 Test Method March 2013 1 2 3 4 1 OVERVIEW The following test method shall be used for determining compliance with
More informationSELECTION GUIDE. Nominal Input
www.murata-ps.com NKE Series FEATURES RoHS Compliant Sub-Miniature SIP & DIP Styles 3kVDC Isolation UL Recognised Wide Temperature performance at full 1 Watt load, 40 C to 85 C Increased Power Density
More informationApplication Note TMA Series
1W, SIP, Single & Dual Output DC/DC Converters Features SIP Package with Industry Standard Pinout Package Dimension: 19.5 x 10.2 x 6.1 mm (0.77 x 0.4 x 0.24 ) 5V&12V Models 19.5 x 10.2 x 7.1 mm (0.77 x
More informationAutomated Multi-Meter Method for the Scaling of Low AC Voltage from 200 mv to 2 mv
Energy and Power Engineering, 2013, 5, 129-134 http://dx.doi.org/10.4236/epe.2013.52012 Published Online March 2013 (http://www.scirp.org/journal/epe) Automated Multi-Meter Method for the Scaling of Low
More informationBuilding the AMP Amplifier
Building the AMP Amplifier Introduction For about 80 years it has been possible to amplify voltage differences and to increase the associated power, first with vacuum tubes using electrons from a hot filament;
More informationHigh Common-Mode Rejection. Differential Line Receiver SSM2141. Fax: 781/461-3113 FUNCTIONAL BLOCK DIAGRAM FEATURES. High Common-Mode Rejection
a FEATURES High Common-Mode Rejection DC: 00 db typ 60 Hz: 00 db typ 20 khz: 70 db typ 40 khz: 62 db typ Low Distortion: 0.00% typ Fast Slew Rate: 9.5 V/ s typ Wide Bandwidth: 3 MHz typ Low Cost Complements
More informationPressure Transducer to ADC Application
Application Report SLOA05 October 2000 Pressure Transducer to ADC Application John Bishop ABSTRACT Advanced Analog Products/OpAmp Applications A range of bridgetype transducers can measure numerous process
More informationAnalog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
More informationMobile Communications DC Sources 40-100 W
40-100 W 66319B/D, 66321B/D Ideal for testing wireless and battery powered devices Several times improvement in measurement throughput over general purpose DC sources Superior output transient performance
More informationFrequency Response of Filters
School of Engineering Department of Electrical and Computer Engineering 332:224 Principles of Electrical Engineering II Laboratory Experiment 2 Frequency Response of Filters 1 Introduction Objectives To
More informationReaction Torque Sensor
Force 1 1 N m up to 1 000 1 000 N m Type 9329A 9389A These easy to install piezoelectric reaction torque sensors are particularly suitable for measuring rapidly changing torques at non-rotating shafts.
More informationSP490/491 Full Duplex RS-485 Transceivers
SP490/491 Full Duplex RS-485 Transceivers FEATURES +5V Only Low Power BiCMOS Driver/Receiver Enable (SP491) RS-485 and RS-422 Drivers/Receivers Pin Compatible with LTC490 and SN75179 (SP490) Pin Compatible
More informationReport Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015
Report Of Shielding Effectiveness Test For SafeSleeve Radiation Shielding Technology Test Date(s): June 07 June 09, 2015 Issue Date: June 10, 2015 UST Project No: 15-0137 Total Number of Pages Contained
More informationThe Universal DAQ Device. Connect and measure immediately!
The Universal DAQ Device. Connect and measure immediately! XXL performance in mini format 8 universal connectors 1) on each QuantumX device suited for most common transducer technologies: 1) See technical
More informationMechanical Dimensions: Height: 3U Width: 427mm (16.8 inches) Depth: 460mm (18.1 inches) Weight: 18.5kg (41lbs). 19kg (42.1lbs) with Option 250
General Specifications Line Power Supply Voltage (single f): 100V/120V/220V/240V selectable from rear panel Variation: ±10% Nominal Voltage Line Frequency: 48Hz to 63Hz Consumption: 450VA max. 500VA max
More informationHandheld portable appliance testers
PAT100 SERIES Handheld portable appliance testers PAT100 SERIES Handheld portable appliance testers Simple Tick/Cross, pass/fail indication plus measurement Battery powered with rechargeable options Includes
More informationAC 2012-3923: MEASUREMENT OF OP-AMP PARAMETERS USING VEC- TOR SIGNAL ANALYZERS IN UNDERGRADUATE LINEAR CIRCUITS LABORATORY
AC 212-3923: MEASUREMENT OF OP-AMP PARAMETERS USING VEC- TOR SIGNAL ANALYZERS IN UNDERGRADUATE LINEAR CIRCUITS LABORATORY Dr. Tooran Emami, U.S. Coast Guard Academy Tooran Emami received her M.S. and Ph.D.
More informationAMP CO Plus Insert for Cat. 6 A Applications
Product Specification 108-93039 10/Mar/2011 Rev F AMP CO Plus Insert for Cat. 6 A Applications 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP* CO Plus
More informationHigh Voltage Power Supplies
Source voltages up to 5kV and 10kV 1µA current measurement resolution Multi-channel programmable DC power supplies Low noise for precision sourcing and sensitive measurements; selectable filters reduce
More informationExample of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.
Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on
More informationSG2525A SG3525A REGULATING PULSE WIDTH MODULATORS
SG2525A SG3525A REGULATING PULSE WIDTH MODULATORS 8 TO 35 V OPERATION 5.1 V REFERENCE TRIMMED TO ± 1 % 100 Hz TO 500 KHz OSCILLATOR RANGE SEPARATE OSCILLATOR SYNC TERMINAL ADJUSTABLE DEADTIME CONTROL INTERNAL
More informationCONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13
CONTENTS PAGE Chapter 1 General Information 1 Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13 Chapter 3 Alarm/Excitation Options 15 Wiring 17 Chapter
More informationAgilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet
Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price Data Sheet Features 120000 counts resolution 16 built-in measurement functions including temperature and
More informationSELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)
OBSOLETE NMPD0 Series SELECTION GUIDE Order Code Nominal Input Voltage Output Voltage Efficiency (Min.) Power (Max.) V V % W NMPD003C 3. 9.50 NMPD005C 5. 9.5 NMPD0C. 0 0.00 NMPD05C 5. 9 0.00 FEATURES RoHS
More informationDigital Clamp-on DMMs with uncompromising performance
Digital Clamp-on DMMs with uncompromising performance With this new range of clamp-on meters, Metrix introduces practical and inexpensive instruments with uncompromising performance. Designed to satisfy
More informationAC Transport constant current vs. low impedance modes
Application Note 184-42 AC Transport constant current vs. low impedance modes The AC Transport option offers the user the ability to put the current source in a low output impedance mode. This mode is
More informationLaboratory 4: Feedback and Compensation
Laboratory 4: Feedback and Compensation To be performed during Week 9 (Oct. 20-24) and Week 10 (Oct. 27-31) Due Week 11 (Nov. 3-7) 1 Pre-Lab This Pre-Lab should be completed before attending your regular
More informationTutorial 12 Solutions
PHYS000 Tutorial 2 solutions Tutorial 2 Solutions. Two resistors, of 00 Ω and 200 Ω, are connected in series to a 6.0 V DC power supply. (a) Draw a circuit diagram. 6 V 00 Ω 200 Ω (b) What is the total
More information