THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES"

Transcription

1 TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

2 IFA 300 Constant Temperature Anemometry (CTA) System SmartTune automatic bridge optimization technology High frequency response (with no tuning) Windows -2-

3 Expansion up to 16 Channels While the basic IFA 300 system can handle up to eight anemometer channels in one cabinet, a total of sixteen anemometers can be monitored and controlled by ThermalPro software with the addition of a second cabinet (and the appropriate digitizer). In case you need two systems, the two IFA 300 cabinets can be used as two separate systems with the purchase of a second A/D converter. Thermal Pro Data Acquisition and Analysis Software The IFA 300 is designed for complete computer control through the ThermalPro software. System operating functions, such as control of the overheat ratios and signal conditioner settings, are handled via an RS232 interface, while the high speed analog data from the anemometer output is managed with a high speed multichannel digitizer installed inside the computer. The ThermalPro software is supplied with the IFA 300 system to allow all control and data acquisition, data analysis and presentation of results. -3-

4 Complete IFA 300 CTA System The complete IFA 300 system is made up of the following components: IFA 300 CTA Multichannel digitizer ThermalPro software Hot Wire/Hot film probe and probe support The IFA 300 unit comes with a single CTA channel, when multiple channels are needed, additional CTA can be purchased (up to 8 channels of CTA). If more than 8 channels are required for your flow research, an IFA 300 auxiliary cabinet is also required. This allows a total of 16 channels to be configured. System Selection Guide Component System with 1 channel System with up to 8 channels System with up to 16 channels IFA 300 IFA 300 auxiliary cabinet (183102) SmartTune CTA module Multichannel digitizer (ADCPCI-4) Multichannel digitizer (ADCPCI-8) (qty of 2) ThermalPro software Hot wire/hot film probes Computer system with Win 7 32-bit OS Air velocity calibration systems Traverse system Air velocity calibration by TSI Water flow calibration by TSI Optional items -4-

5 IFA 300 Specifications Amplifier drift Amplifier input noise Frequency response Resistance measurement Operating resistance Maximum probe current Cable length Output Size Number of channels Input power Temperature measurement Signal conditioning Offset Gain Low pass filters High pass filters Output (analog) Accessories included 0.3 μv/ C 1.7 nv/-hz and 1.5 pa/-hz >250 khz (without tuning) 0.1% ±0.01 ohms 2 to 80 ohms 800 ma (1.6 A with high power setting) 5 m; RG-58 A/U (other lengths available on request) Bridge voltage to 11.5 volts 17.8 cm x 48 cm x 41 cm (7 in. x 19 in. x 16 in.); standard 19-inch rack mount Up to eight per cabinet; sixteen channels supported by standard software 100/120/220/240 VAC, Hz, no switching required Thermocouple circuit built-in for type-t thermocouple 0 to 10 V in 10 mv steps, 0.15% accuracy 1 to 1000 (1.0 MHz maximum bandwidth), 0.15% accuracy Linear phase, 12 Hz to 1 MHz; 13 settings; -60 db/decade 0.1, 1, 10 Hz; 60 db/decade 5 to +5 V One 5-meter probe cable per channel, one 2-meter output cable per channel (plus 2 extra per system), one Model 1340 thermocouple, one Model 1341 thermocouple cable, one BNC shorting cap (coaxial), one BNC T connector, power cable(s), one 4-meter (12 ft) RS232 cable, one shorting probe for singlesensor probe supports and one for dual-sensor probe supports -5-

6 Air Velocity Calibrators Three models of air velocity calibrators are offered. They are: Model 1127 Model 1128A Model 1129 Manual velocity calibrator without pressure transducer B and C Manual velocity calibrator with different pressure transducer (0 to 100 mm Hg; 0 to 100 mmhg and mmhg respectively) Automatic velocity calibrator with 0 to 100 mm Hg pressure transducer The velocity calibrator can be used with one-, two-, or three sensor probe and provides the probe mounts for yaw/pitch calibration. The calibrator is also integrated with the IFA 300 and the ThermalPro software so that the data acquisition and calibration can be perfumed with accuracy and convenience. When the Model 1129 automatic velocity calibrator is used, the calibration becomes very easy. Just define a velocity range in the ThermalPro software and attach a probe, the calibrator monitors the velocity through the output of a built-in pressure transducer, acquires sensor data, adjusts the flow rate to a new velocity, and repeats the process, until the entire velocity range is covered. The data is automatically integrated into the software calibration section. While the calibrator s most obvious benefit is automated control, it has several other advanced design features. For one, its exclusive flow nozzle design exhibits a flat velocity profile over a broad dynamic range. For another, it sports a probe mounting system that can handle any type probe and probe support with great positioning flexibility, essential for yaw and pitch calibration of probes. -6-

7 Computer Controlled Traverse Systems Three different computer-controlled traverses are offered, Models and 1193, each able to precisely locate and move a probe. As part of an anemometer system, they enable automated measurement or remote operation. Typically, they are controlled using ThermalPro software, where a customer defined matrix identifies the measurement points. They also operate independently using front panel controls and displays on the power supply. All traverses are built to ensure stable operation over the full translation range. They feature 600 mm travel with 10μm resolution, both absolute and relative homing capability, and a universal probe mount with tilt. The three models differ only in the number of axes of movement. Specifications of the Traverse Systems Resolution 10 μm Accuracy ±50 μm/ft Repeatability ±20 μm Traversing speed 10 mm/s Backlash compensation Yes Limit switch settings Adjustable Stepper motor 200 steps/revolution Remote control RS232 Front panel LED display Position of each axis Front panel control Pushbutton; jog/slew from front panel Power source 110 VAC ±10%, 60 Hz standard; 220 VAC ±10%, 50/60 Hz optional Probe mount Manual rotation and translation of probe Model 1191 Model 1192 Model 1193 Axes Horizontal Horizontal/vertical Three axis Traversing length by by 600 by 600 (mm) Weight (including 29 kg 54 kg 104 kg mount Dimensions (mm) excluding mount 1070 x 100 x x 1100 x x 1100 x

8 Calibration Services TSI provides calibration data, supplied on disk, for all probes it manufactures. When ordering, indicate the velocity range in air (0 to 5 m/s, 0 to 50 m/s, or 0 to 100 m/s) or water (0 to 1 m/s or 0 to 5 m/s). Start-up Anemometer Systems Model 1750 Constant Temperature Anemometer Module The Model 1750 Constant Temperature Anemometer (CTA) is designed for startup multi-channel applications. Users typically incorporate the 1750 in their existing data acquisition and control system, and therefore it does not include any software, output signal conditioner, or computer interface. The following components are needed to be used with the Model 1750 CTA module to make up the complete system: Model 1751 Power Supply Model 1304 Control Resistor Single sensor wire or film probe Model Probe adaptor, or equivalent Model CL-CAL1750AIR calibration (please specify your velocity range) Each 1750 interfaces with a single-sensor anemometer probe. The 1750 system does not include signal conditioning, hence any offset and gain applied to the output voltage needs to be within the range of your analog to digital converter (typically -5 to +5V or 0 to 10V). Optimization of the frequency response can be achieved by adjusting the Trim and Gain controls on the anemometer. Specifications Number of channels Amplifier input noise Frequency response Maximum probe current Maximum bridge voltage Output voltage range Analog output impedance Sensor operating resistance Cable length Size (including mounting flange) Input Voltage Operating temperature 0 to 50 C One 7 nv/ Hz DC to 100 khz(3.8 μm) diameter tungsten wire, 100 m/s velocity 0.75 VDC Supply 22 VDC Supply 8 to 22 VDC Supply 50 Ω From 4 Ω to 20 Ω 2 m 11.4 cm x 10.7 cm x 2.8 cm (4.5 in. x 4.2 in. x 1.1 in.) 12 to 25 VDC -8-

9 Model 1745 Constant Current Anemometer module The Model 1745 Constant Current Anemometer (CCA) module is a stand-alone anemometer designed to measure average as well as instantaneous temperatures in the 0 o C to 300 o C range. The module is to be used with wire or film sensor operating as cold probe to allow the rapid measurements of temperature. The output from the anemometer is analog voltage reading directly dependent upon the actual temperature of the flow. Zero adjust and gain features allow convenient scaling of the output during calibration and measurement. Specifications Input power +15 VDC ±10%, 250 m/a Output range -12 VDC to +12 VDC, BNC output or terminal strip Sensor current Up to 2 ma Gain Continuous from 50 to 1000 Frequency response Up to 1 khz Proudly represented in Australia and New Zealand by: TSI Incorporated Visit our website for more information. P/N Rev A. (10/25/2013) 2013 TSI Incorporated Printed in U.S.A.

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give

More information

Research RF Sputtering Packages

Research RF Sputtering Packages Research RF Sputtering Packages Shown with 3" Polaris Adjustable Position Source with Tilt and Shutter 300 or 600 Watt Low Cost Packages for Those With Limited Budgets Desiring Full Capability 13.56 MHz

More information

Physical Specifications (Custom design available.)

Physical Specifications (Custom design available.) Helmholtz Coils A useful laboratory technique for getting a fairly uniform magnetic field, is to use a pair of circular coils on a common axis with equal currents flowing in the same sense. For a given

More information

Signal Conditioning Amplifier System

Signal Conditioning Amplifier System Micro-Measurements A2 FEATURES Strain gage, transducer, and thermocouple inputs Frequency response to 110 khz Analog output of ±10 VDC Operation with 12 to 15 VDC and 120/240 VAC power Scalable from 8

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

The Universal DAQ Device. Connect and measure immediately!

The Universal DAQ Device. Connect and measure immediately! The Universal DAQ Device. Connect and measure immediately! XXL performance in mini format 8 universal connectors 1) on each QuantumX device suited for most common transducer technologies: 1) See technical

More information

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card Machinery Protection Card Type FEATURES Continuous on-line Machinery Protection Card Real-time measurement and monitoring using state-of-the-art DSP techniques Fully VME-compatible slave interface Fully

More information

Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz

Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity

More information

1.44 kw Programmable DC Power Supplies XLN Series

1.44 kw Programmable DC Power Supplies XLN Series Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable

More information

Signal Conditioning Amplifier System

Signal Conditioning Amplifier System A2 Micro-Measurements FEATURES Strain gage, transducer, and thermocouple inputs Frequency response to 110kHz Analog output of ±10VDC Operation with 12 to 15VDC and 120/240Vac power Scalable from 8 to 128

More information

Agilent 4339B/4349B High Resistance Meters

Agilent 4339B/4349B High Resistance Meters Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance

More information

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and

More information

Ordering Part Numbers: Universal Signal Converter: USC-CVB225-01 Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Ordering Part Numbers: Universal Signal Converter: USC-CVB225-01 Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V Description: The universal signal converter offers threeway isolation and translates one input control signal into one to three simultaneous outputs. Switches allow the user to select the desired input

More information

WEATHER STATION FOR SOLAR FARM MONITORING

WEATHER STATION FOR SOLAR FARM MONITORING WEATHER STATION FOR SOLAR FARM MONITORING SOLAR FARM MONITORING SYSTEM: Measures global, horizontal, & background irradiance. Measures wind speed, wind direction, ambient temperature, and relative humidity.

More information

Measuring Temperature withthermistors a Tutorial David Potter

Measuring Temperature withthermistors a Tutorial David Potter NATIONAL INSTRUMENTS The Software is the Instrument Application Note 065 Measuring Temperature withthermistors a Tutorial David Potter Introduction Thermistors are thermally sensitive resistors used in

More information

Current Probes. User Manual

Current Probes. User Manual Current Probes User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall

More information

MiniCTA and Multichannel CTA Systems

MiniCTA and Multichannel CTA Systems MiniCTA and Multichannel CTA Systems Compact CTA Systems for accurate flow investigations Applications Features Flow velocity and turbulence measurements For applications in air (up to 100 m/s) and in

More information

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings. TECHNICAL DATASHEET #TDAX06070X Triaxial Inclinometer with Gyro ±180⁰ Pitch/Roll Angle Pitch Angle Rate Acceleration SAE J1939, Analog Output or RS-232 Options 2 M12 Connectors, IP67 with Electronic Assistant

More information

On-line Machine Condition Monitoring [The CMS System]

On-line Machine Condition Monitoring [The CMS System] On-line Machine Condition Monitoring [The CMS System] Strategic monitoring control your costs Avoid unplanned downtime Monitor your plant stoppers Early warning maintains profit Efficient and profitable

More information

Digital/Analogue Signal Converters/Multiplexers Section F

Digital/Analogue Signal Converters/Multiplexers Section F Section F The conversion of Analogue signals to digital is an important part of many control systems. So is the conversion of serial data between various standards (RS, RS485 and RS4 for example). www.weidmüller.com.au

More information

CPL350 Capacitive Displacement Sensor

CPL350 Capacitive Displacement Sensor INSTRUCTION MANUAL CPL350 Capacitive Displacement Sensor Lion Precision 563 Shoreview Park Road St. Paul, Minnesota 55126-7014 Telephone: 651-484-6544 Fax: 651-484-6824 www.lionprecision.com Copyright

More information

DPI 260 SERIES: Digital Pressure Indicators

DPI 260 SERIES: Digital Pressure Indicators DPI 260 SERIES: Digital Pressure Indicators INTRODUCTION The DPI 260, 261 and 262 range of digital pressure instruments measure and indicate pressure in any specified scale units and provide accuracies

More information

Manatronics 48V / 200 Amp Load

Manatronics 48V / 200 Amp Load Manatronics 48V / 200 Amp Load For Battery Discharge testing and Power Supply testing 30 th Jan. 2008 Model No. BD 12-48P Product Datasheet 48V / 200 Amp Electronic Load Features: Quality Product Rugged

More information

INTREPID Perimeter Intrusion Detection System

INTREPID Perimeter Intrusion Detection System TM INTREPID Perimeter Intrusion Detection System Next Generation Perimeter Protection icropoint Cable combines patented Southwest Microwave technology with microprocessor power and laptop computer convenience.

More information

Perimeter Security System

Perimeter Security System TM Perimeter Security System The Next Generation Perimeter Security System ICRONET combines patented Southwest Microwave technology with microprocessor power and laptop computer convenience. It is a sophisticated

More information

PicoLog 1000 Small Terminal Board

PicoLog 1000 Small Terminal Board PicoLog 1000 Small Terminal Board User s Guide DO161-3 Pico Technology Small Terminal Board User Guide CONTENTS 1 Overview 1 1.1 Introduction 1 1.2 Specifications 1 1.3 Connecting the Terminal Board to

More information

22.302 Experiment 5. Strain Gage Measurements

22.302 Experiment 5. Strain Gage Measurements 22.302 Experiment 5 Strain Gage Measurements Introduction The design of components for many engineering systems is based on the application of theoretical models. The accuracy of these models can be verified

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

Multi-Range Programmable DC Power Supplies 9115 Series

Multi-Range Programmable DC Power Supplies 9115 Series Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,

More information

High Voltage Power Supplies

High Voltage Power Supplies Source voltages up to 5kV and 10kV 1µA current measurement resolution Multi-channel programmable DC power supplies Low noise for precision sourcing and sensitive measurements; selectable filters reduce

More information

Agilent 4338B Milliohm Meter

Agilent 4338B Milliohm Meter Agilent 4338B Milliohm Meter 10 µω to 100 kω Technical Overview Introduction Ideal for precise measurements of extremely low resistances using an ac test signal, the Agilent Technologies 4338B suits bench-top

More information

Model 2182A. Instrument specifications. Specification conditions. Voltage specifications

Model 2182A. Instrument specifications. Specification conditions. Voltage specifications Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 2182A Instrument specifications Specification conditions This document contains specifications

More information

ADC-20/ADC-24 Terminal Board. User Guide DO117-5

ADC-20/ADC-24 Terminal Board. User Guide DO117-5 ADC-20/ADC-24 Terminal Board User Guide DO117-5 Issues: 1) 8.11.05 Created by JB. 2) 13.12.05 p10: added 0V connection to thermocouple schematic. 3) 22.3.06 p11: removed C1. 4) 20.8.07 New logo. 5) 29.9.08

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

Digital Magnetometer Systems - DM Series

Digital Magnetometer Systems - DM Series The Digital Magnetometer DM Series DM 005, DM-010, DM 050 and DM-060 are digital 3 axes magnetometer systems for precise measurement of magnetic fields and also applicable for underwater operation. All

More information

Personal Daq/50 Series USB Data Acquisition Modules Models /54, /55, & /56

Personal Daq/50 Series USB Data Acquisition Modules Models /54, /55, & /56 USB Data Acquisition Modules Models /5, /55, & /56 Features Multifunction data acquisition modules attach to PCs via Universal Serial Bus (USB 1.1 & 2.0 compatible) Ultra low-power design requires no external

More information

Data Acquisition (DAQ) System. B.1 Introduction

Data Acquisition (DAQ) System. B.1 Introduction Data Acquisition (DAQ) System B.1 Introduction One of the greatest advancements in experimentation has been the use of computers to automatically retrieve data. Generally speaking, a computerized data

More information

Contents. Document information

Contents. Document information User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB

More information

Data Sheet SIMATIC S7-200 CPU 226 DC/DC/DC and CPU 226 AC/DC/Relay

Data Sheet SIMATIC S7-200 CPU 226 DC/DC/DC and CPU 226 AC/DC/Relay SIMATIC S7-200 and Table 1 Specifications for and Physical Size Dimensions (W x H x D) Weight Power loss (dissipation) CPU Features On-board digital inputs On-board digital outputs High speed counters

More information

Analog Expansion Modules Input Specifications

Analog Expansion Modules Input Specifications S7-2 Programmable ontroller System Manual Analog Expansion Modules Specifications Table A-15 Analog Expansion Modules Order Numbers Order Number Expansion Model EM Inputs EM Outputs emovable onnector 6ES7

More information

Designing interface electronics for zirconium dioxide oxygen sensors of the XYA series

Designing interface electronics for zirconium dioxide oxygen sensors of the XYA series 1 CIRCUIT DESIGN If not using one of First Sensors ZBXYA interface boards for sensor control and conditioning, this section describes the basic building blocks required to create an interface circuit Before

More information

GA-200 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-200 Gas Analyzer

GA-200 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-200 Gas Analyzer Technical Note Overview The uses sensors to measure and display the concentrations of oxygen and carbon dioxide in a sample as the percentage of a gas in the sample by volume. This method of expressing

More information

VMU 100. Vibration Monitor VibroSmart FEATURES. Single-channel microprocessor-based monitor for mv/g accelerometer (constant current supply)

VMU 100. Vibration Monitor VibroSmart FEATURES. Single-channel microprocessor-based monitor for mv/g accelerometer (constant current supply) Vibration Monitor VibroSmart FEATURES Single-channel microprocessor-based monitor for mv/g accelerometer (constant current supply) Designed for reliable operation in severe industrial environments (IP

More information

Agilent 8753ET/8753ES Network Analyzers

Agilent 8753ET/8753ES Network Analyzers Agilent 8753ET/8753ES Network Analyzers 8753ET, 300 khz to 3 or 6 GHz 8753ES, 30 khz to 3 or 6 GHz Configuration Guide System configuration summary The following summary lists the main components required

More information

Description. Specifications All Specifications are at 23 C ± 2 C, (73.4 F ± 3.6 F)

Description. Specifications All Specifications are at 23 C ± 2 C, (73.4 F ± 3.6 F) Specifications and Ordering Information 1701/06 FieldMonitor Isolator Terminal Base and 170190 Dual Galvanic Isolator for Hazardous Areas Description The 1701/06 Isolator Terminal Base (ITB) and 170190

More information

CLS Steering Effort Sensor for Automobiles and Trucks

CLS Steering Effort Sensor for Automobiles and Trucks CLS Steering Effort Sensor for Automobiles and Trucks CAEMAX Technologie GmbH Bunzlauer Platz 1 D-80992 München Telefon: 089 61 30 49 0 Telefax: 089 61 30 49 57 info@caemax.de www.caemax.de 1 Exclusion

More information

CAPACITIVE SENSORS Position Displacement High Speed High Resolution

CAPACITIVE SENSORS Position Displacement High Speed High Resolution Precise Noncontact Sensors and Experts to Help You Use Them CAPACITIVE SENSORS Position Displacement High Speed High Resolution Off-The-Shelf and Customized Solutions Lion Precision Established 1958 ISO

More information

Precise Measurement FAQs

Precise Measurement FAQs Precise Measurement FAQs Here are some Frequently Asked Questions and Answers associated with low level measurements. If you don t find answers to your questions here, you can send a specific question

More information

HD402T Pressure Transmitters

HD402T Pressure Transmitters HD402T Pressure Transmitters Sensor with high accuracy and stability Measurement of pressures relative to the atmosphere or differential pressures Dual analogue output: current and voltage Versions with

More information

Multi-Channel Programmable DC Power Supplies

Multi-Channel Programmable DC Power Supplies Dual and triple output models with two 30V/1.5A (45W) channels and a 6V/5A (30W) channel on the triple output supply All channels are independently controlled and have isolated outputs for maximum flexibility

More information

APPLICATION NOTE - 016

APPLICATION NOTE - 016 APPLICATION NOTE - 016 Testing RFI Line Filters Frequency Response Analysis Testing RFI line filters Radio frequency interference (RFI) is unwanted electromagnetic noise within a radio communications frequency

More information

Multi-Range Programmable DC Power Supplies 9115 Series

Multi-Range Programmable DC Power Supplies 9115 Series Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional

More information

MODEL 27106D GILL PROPELLER ANEMOMETER JANUARY 2003 MANUAL PN 27106D-90 R. M. YOUNG COMPANY

MODEL 27106D GILL PROPELLER ANEMOMETER JANUARY 2003 MANUAL PN 27106D-90 R. M. YOUNG COMPANY MODEL 27106D GILL PROPELLER ANEMOMETER JANUARY 2003 MANUAL PN 27106D-90 R. M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 MODEL 27106D

More information

Electrical calibration

Electrical calibration Electrical calibration Electrical calibration refers to the process of verifying the performance of, or adjusting, any instrument that measures, sources, or tests electrical parameters. This discipline

More information

DX602-C1 Two Antenna Diversity Receiver for UAV

DX602-C1 Two Antenna Diversity Receiver for UAV DX602-C1 Two Antenna Diversity Receiver for UAV User's Guide & Operating Manual AV010220/1-000 REV. X0 14 Oct 2005 Edited by Guru Mujumdar http://www.avalonrf.com/ Avalon RF, Inc. 344 Coogan Way El Cajon,

More information

MILA Distributed Control System Specification. Figure 1 MILA Distributed Controller With Built-in Relays

MILA Distributed Control System Specification. Figure 1 MILA Distributed Controller With Built-in Relays MELLEN MILA Distributed Control System Specification Figure 1 MILA Distributed Controller With Built-in Relays Figure 2 MILA Distributed Controller (-NR Model) MILA Specification Copyright 2013 - The MELLEN

More information

Innovation in Magnetic Field Measuring Instruments. Data Acquisition and Signal Conditioning Units

Innovation in Magnetic Field Measuring Instruments. Data Acquisition and Signal Conditioning Units Innovation in Magnetic Field Measuring Instruments Data Acquisition and Signal Conditioning Units Data Acquisition and Signal Conditioning Units Bartington Data Acquisition and Signal Conditioning Units

More information

Note 7. Sensors and Data Acquisition (2)

Note 7. Sensors and Data Acquisition (2) Note 7 Sensors and Data Acquisition (2) 1 2. Wheatstone Bridge Circuit The Wheatstone bridge circuit, as shown in Figure 4, is used to convert the change in resistance into voltage output. It is a standard

More information

Differential Charge Amplifier

Differential Charge Amplifier Electronics Differential Type 58A... The differential charge amplifier is used for signal conversion of piezoelectric sensors with differential output. Executions Aluminum die-cast enclosure (IP64) Plastic

More information

A.4 Specifications for the CPU 224

A.4 Specifications for the CPU 224 A.4 Specifications for the CPU 224 Specifications for and Physical Size Dimensions (W x H x D) Weight Power loss (dissipation) CPU Features On-Board digital inputs On-Board digital outputs High speed counters

More information

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE Technical Teaching Equipment Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE EDIBON SCADA System Teaching Technique used 4 5 2 Data Acquisition Board Cables and

More information

O C M III. Open Channel Flow Monitor

O C M III. Open Channel Flow Monitor O C M III Open Channel Flow Monitor Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow transmitter with sensor and temperature compensation probe. B. Under this

More information

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology Tilt switches MEMS technology, one or two axis N3 / N4... + long lifetime and highly reliability due to mechanism-free MEMS technology + combinable output signals + one or two axis measurement + tilt range

More information

Measuring Temperature with RTDs A Tutorial

Measuring Temperature with RTDs A Tutorial Application Note 046 Measuring Temperature with RTDs A Tutorial Introduction A resistancetemperature detector (RTD) is a temperature sensing device whose resistance increases with temperature. An RTD consists

More information

PRODUCT PROFILE FEATURES

PRODUCT PROFILE FEATURES PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER

More information

Thermal Dispersion Probe Airflow Measuring System

Thermal Dispersion Probe Airflow Measuring System Datasheet Thermal Dispersion Probe Airflow Measuring System Overview The AV-ASTNN Thermal Dispersion Probe Airflow Measuring System Series averages velocity and temperature from up to four probes and sixteen

More information

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate Quadrature Encoder Position & Rate Meter Features Accepts low-level differential or single-ended 5V logic level outputs from quadrature encoders Quadrature count x1, x2

More information

Instruction Manual Model Constant Temperature Anemometer

Instruction Manual Model Constant Temperature Anemometer Instruction Manual Model 1750 Constant Temperature Anemometer Manual History The following is a manual history of the Model 1750 Constant Temperature Anemometer (part number 1990185). Revision Date First

More information

Impedance 50 (75 connectors via adapters)

Impedance 50 (75 connectors via adapters) VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:

More information

Measure Pressure and Flow

Measure Pressure and Flow Measure Pressure and Flow Install the EMANT300 USB DAQ and Stepper Motor Training Kit 1. Connect up the EMANT300 USB DAQ and Pressure and Air pump Adaptor as shown. EMANT300 USB DAQ Pressure and Air pump

More information

HIGH RELIABILITY POWER SUPPLY TESTING

HIGH RELIABILITY POWER SUPPLY TESTING HIGH RELIABILITY POWER SUPPLY TESTING Dale Cigoy Keithley Instruments, Inc. The reliability of a power supply must match or exceed the rest of the system in which it is installed. Generally, this requires

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature

More information

DDC864 DIGITAL DOWNCONVERTER 1. 2 FRONT PANEL CONTROLS and INDICATORS 12 POSITION RACK MOUNT POWER SUPPLY DDC864. Figure 1 DOWNCONVERTER

DDC864 DIGITAL DOWNCONVERTER 1. 2 FRONT PANEL CONTROLS and INDICATORS 12 POSITION RACK MOUNT POWER SUPPLY DDC864. Figure 1 DOWNCONVERTER TM DIGITAL DOWNCONVERTER 1 2 FRONT PANEL CONTROLS and INDICATORS 12 POSITION RACK MOUNT SUPPLY F1 F2 SUPPLY PS8 F3 F4 DOWNCONVERTER The R.L. Drake is a low noise downconverter designed for translating

More information

USB Smart Power Sensor

USB Smart Power Sensor 50Ω -30 dbm to +20 dbm, 9 khz to 4000 MHz The Big Deal Low cost USB HID device compatible with 32/64 Bit operating systems Includes Measurement Application GUI (Graphical User Interface) software with

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

ADC-11 Terminal Board. User s Guide DO037-6

ADC-11 Terminal Board. User s Guide DO037-6 ADC-11 Terminal Board User s Guide DO037-6 Issues: 1) Obsolete. 2) Obsolete. 3) 13.11.03. A5 Word format. Not issued. 4) 28.3.06. Erie format. Typographic errors fixed. 5) 12.7.07. Chantilly format. D0

More information

DSA800 Series Spectrum Analyzer

DSA800 Series Spectrum Analyzer DSA800 Series Spectrum Analyzer Configuration Guide This guide is used to help users to configure DSA800 series spectrum analyzer according to their requirements. You can get an overall understanding of

More information

NETWORK ENABLED EQUIPMENT MONITOR

NETWORK ENABLED EQUIPMENT MONITOR NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone

More information

LAUREL. Laureate Quadrature Encoder Position & Rate Meter ELECTRONICS, INC. Features. Description

LAUREL. Laureate Quadrature Encoder Position & Rate Meter ELECTRONICS, INC. Features. Description LAUREL ELECTRONICS, INC. Laureate Quadrature Encoder Position & Rate Meter Features Accepts low-level differential or single-ended 5V logic level outputs from quadrature encoders Quadrature count x1, x2

More information

Unitary Controller. Features. Description. Technical Specification Sheet Document No. 149-188P25 Rev. 6 March, 2000

Unitary Controller. Features. Description. Technical Specification Sheet Document No. 149-188P25 Rev. 6 March, 2000 Technical Specification Sheet Document No. 149-188P25 Rev. 6 March, 2000 Unitary Controller The Unitary Controller can operate as an independent stand-alone controller, or can be connected to the APOGEE

More information

LOXONE 12 Channel Amplifier

LOXONE 12 Channel Amplifier LOXONE 12 Channel Amplifier Item no.: 200110 Thank you for purchasing the Loxone Twelve Channel Amplifier. The versatility of the Amplifier makes it the perfect choice for almost every type of custom multi-room

More information

Description. Output Stage. 5k (10k) - + 5k (10k)

Description. Output Stage. 5k (10k) - + 5k (10k) THAT Corporation Low Noise, High Performance Audio Preamplifier IC FEATURES Low Noise: 1 nv/hz input noise (60dB gain) 34 nv/hz input noise (0dB gain) (1512) Low THD+N (full audio bandwidth): 0.0005% 40dB

More information

Typical Aluminum GFM Mass Flow Meter

Typical Aluminum GFM Mass Flow Meter MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.

More information

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise

More information

Agilent 8903B Audio Analyzer, 20 Hz to 100 khz

Agilent 8903B Audio Analyzer, 20 Hz to 100 khz Agilent 8903B Audio Analyzer, 20 Hz to 100 khz Product Overview Versatile The Agilent Technologies 8903B Audio Analyzer provides unparalleled versatility and performance for audio measurements from 20

More information

Application Note TMA Series

Application Note TMA Series 1W, SIP, Single & Dual Output DC/DC Converters Features SIP Package with Industry Standard Pinout Package Dimension: 19.5 x 10.2 x 6.1 mm (0.77 x 0.4 x 0.24 ) 5V&12V Models 19.5 x 10.2 x 7.1 mm (0.77 x

More information

&"#' ( "#' )*! #+ #,# 1" 1! 2"# ' 6! #* #!"#" +" )$# # # "#$#$ '2 2 ## #1##9 # # ##2 #( # 8##! #9# 9@8!( " " "32#$#$2#9 # "#!#1#$#$#9 '29# # #9$

&#' ( #' )*! #+ #,# 1 1! 2# ' 6! #* #!# + )$# # # #$#$ '2 2 ## #1##9 # # ##2 #( # 8##! #9# 9@8!(   32#$#$2#9 # #!#1#$#$#9 '29# # #9$ !"## $#!%!"# &"#' ( "#' )*! #+ #,# "##!$ -+./0 1" 1! 2"# # -&1!"#" (2345-&1 #$6.7 -&89$## ' 6! #* #!"#" +" 1##6$ "#+# #-& :1# # $ #$#;1)+#1#+

More information

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute

More information

AN AUTOMATIC DC CURRENT COMPARATOR RESISTANCE BRIDGE

AN AUTOMATIC DC CURRENT COMPARATOR RESISTANCE BRIDGE AN AUTOMATIC DC CURRENT COMPARATOR RESISTANCE BRIDGE Duane Brown Measurements International Ltd. ABSTRACT The principle of the Direct Current Comparator has been around for some 30 years, however, very

More information

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem The Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem (DPC3010) provides DOCSIS broadband service providers with a cost-effective solution for delivering high-speed

More information

SDI Multi Sensor Module with Charger Enclosure Station Support

SDI Multi Sensor Module with Charger Enclosure Station Support Description The purpose of the is to provide a low power temperature compensated battery charge controller and a general-purpose interface for analog sensors. Sensor and charge controller data are acquired

More information

OM 21. Programmable benchtop microohmmeter High accuracy: 0.03 %

OM 21. Programmable benchtop microohmmeter High accuracy: 0.03 % Programmable benchtop microohmmeter High accuracy: 0.03 % OM 21 benchtop micro-ohmmeter is used for 4-wire measurement of very low resistance values up to 20 kω with an accuracy of 0.03% RDG and a 0.1

More information

AMETEK s Elgar SW and California Instruments CSW Form, Fit and Functions Comparison

AMETEK s Elgar SW and California Instruments CSW Form, Fit and Functions Comparison AMETEK s Elgar SW and California Instruments CSW Form, Fit and Functions Comparison Introduction The purpose of this technical note is to compare the differences between the discontinued Elgar SW Series

More information

MODEL 1211 CURRENT PREAMPLEFIER

MODEL 1211 CURRENT PREAMPLEFIER MODEL 1211 CURRENT PREAMPLEFIER Phone: (607)539-1108 Email: info@dlinstruments.com www.dlinstruments.com The Model 1211 Current Preamplifier was designed to provide all of the features required of a modern

More information

24 Vdc Power Supplies AL-1535, AL-1536

24 Vdc Power Supplies AL-1535, AL-1536 Product Description Altus Energy Series is a reliable solution for one of the most critical issues in industrial applications: supplying power for all devices in an automation system. With a robust, compact

More information

PLC Line. USER S MANUAL Catalog No Rev. E

PLC Line. USER S MANUAL Catalog No Rev. E PLC Line USER S MANUAL Catalog No. 100125 Rev. E May 2015 Copyright 2015 Intelitek Inc. PLC Line User s Manual Catalog No. 100125 Rev. E May 2015 Every effort has been made to make this technical note

More information

Lab E1: Introduction to Circuits

Lab E1: Introduction to Circuits E1.1 Lab E1: Introduction to Circuits The purpose of the this lab is to introduce you to some basic instrumentation used in electrical circuits. You will learn to use a DC power supply, a digital multimeter

More information

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing U.S. patent#: 5,548,501, 6,054,865. Other patents pending. Safety agency listed. ENHANCED GRAPHIC LCD The

More information

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem The Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem (DPC3010) provides DOCSIS broadband service providers with a cost-effective solution for delivering high-speed

More information