1 00 IS Catalog Page Introduction Transmitter (8 V entity parameter) KFD-CR-Ex (-wire transmitter) KFD-CR-Ex (- or 3-wire transmitter) KFD-CR-Ex C (- or 3-wire, sink mode output) KFD-CR-Ex (- or 3-wire, 4-0 ma input, 0-0 ma output) KFD-CV-Ex (- or 3-wire, 0/4-0 ma input, 0/1-5 V output)... 5 KFD-CV-Ex (- or 3-wire, 0/4-0 ma input, 0/-10 V output) Transmitter (0 V Entity Parameter) KFD-CR-Ex (-wire, 4-0 ma input and output) KFD-CR-Ex (- or 3-wire, 0/4-0 ma input and output) SMART Transmitter (0-1 khz) KFD-STC1-Ex1 (SMART, 4-0 ma input and output) KFD-STV1-Ex1 (SMART, 4-0 ma input, 1-5 V output) SMART Transmitter (0-40 khz) KFD-STC3-Ex1 (4-0 ma input and output) KFD-STV3-Ex1-1 (4-0 ma input, 1-5 V output) KFD-STV3-Ex1- (4-0 ma input, -10 V output) HART Transmitter KFD-STC4-Ex1 (dual-channel, 4-0 ma input and output) KFD-STC4-Ex (dual-channel, 4-0 ma input and output)... 6 KFD-STC4-Ex-Y7195 (dual-channel, sink mode output) KFD-STC4-Ex1.0 (single-channel, outputs) KFD-STC4-Ex1.0-Y716 (single-channel, sink mode output) Pepperl+Fuchs Inc. Telephone (330) FAX (330)

2 00 IS Catalog Introduction Transmitter power supplies transfer 4-0 ma signals from transmitters in hazardous areas and supply them with power. They deliver an electrical signal that is proportional to a measured value such as temperature, pressure or flow from hazardous areas to safe areas. The power supply and signal are transferred through the same conductors in -wire transmitters allowing only 4-0 ma signals. The power supply and signal are isolated from one another in 3-wire transmitters allowing for 0 ma signals. These ma signals can then be repeated on the safe side of the isolator or can be converted to other usable signals such as voltage. SMART transmitter power supplies repeat the transmitter current in addition to a digital signal, which is modulated onto the 4-0 ma signal. SMART transmitters can be calibrated remotely. This allows the transmitter s span and zero set point to be modified in the safe area and information on scheduled maintenance or statistical data to be accessed on-line. SMART transmitters normally operate in a -wire mode. This -wire connection is usually interfaced with a hand-held terminal or a PC for data transmission or accumulation. P+F SMART transmitter power supplies are shipped with terminal blocks to allow easy access to communication leads. SMART transmitters from ABB, Bailey, Chessel, Edress+Hauser, Fisher- Rosemount, Foxboro, Honeywell, Smar and Yokogawa have been successfully tested with P+F isolators. Please note that some higher communication frequencies require use of the KFD-STC3- Ex1 or the KFD-STV3-Ex1. These isolators are rated for frequencies up to 40 khz. Pepperl+Fuchs Inc. Telephone (330) FAX (330)

3 00 IS Catalog Transmitter Power rail or terminals 11+, VDC 1.6 W Input (intrinsically safe) Terminals 1+, 3- Input Signal 4-0 ma at 0 ma 17.6 VDC Output (not intrinsically safe) Terminals 7-, 8+, ma 0 VDC Load 1 kω < 0 µa ss KFD-CR-Ex Rise time ±10 µa nonlinearity, load fluctuations ± 0. µa/ºc range 0-60ºC 50 µs (at 50 Ω load) Analog Input Transmitters -wire transmitter power supply 1 kω max. output load 3-way isolation Suitable for Division mounting repeats the 4-0 ma signal from a - wire transmitter in hazardous areas. It has an open circuit voltage of 5 V with a minimum of 17.6 V at 0 ma. The transmitter must be connected to terminals 1 and 3 so the 4-0 ma transmitter current flows into the measurement circuit via terminal 3. A maximum load of 1 kω can be connected between terminals 7 and 8. Entity Parameters Terminals 1+, 3- FM control drawing no Voltage V OC 9 V Current I SC 96.1 ma ) 0.13 µf 0.39 µf 1.05 µf ) 3.60 mh mh mh 107 x 0 x 115 Weight 3.5 oz. (100 g) CSA approvals available upon request -0ºC to +60ºC (-4ºF to +140ºF) Safe Area or Div KFD-CR-Ex Pepperl+Fuchs Inc. Telephone (330) FAX (330)

4 Analog Input Transmitters 00 IS Catalog Power rail or terminals 11+, VDC 1.7 W Transmitter Input (intrinsically safe) Terminals 1+, -, 3 Input 0/4-0 ma (term. 1+, -) 16.5 V at 5 ma (term. 1+, 3) 13.6 V at 0 ma Input resistance (term. -, 3) 0 Ω Output (not intrinsically safe) Terminals 7-, 8+, 9-0/4-0 ma 0 VDC Load 1 kω 0 µa ss ±10 µa nonlinearity, load fluctuations ± 0. µa/ºc range 0-60ºC Rise time 50 µs Entity Parameters Terminals 1+, 3 -, 3 FM control drawing no Voltage V OC 8 V 4.4 V Current I SC 93 ma. ma Terminals 1+, 3 ) 0.14 µf 0.43 µf 1.14 µf ) 4.18 mh mh 34.1 mh Terminals -, 3 ) 1000 µf 3000 µf 8000 µf ) 67.8 mh 39 mh 597 mh 107 x 0 x 115 mm Weight 100 g (3.5 oz.) CSA approvals available upon request -0ºC to +60ºC (-4ºF to +140ºF) Safe Area or Div KFD-CR-Ex KFD-CR-Ex or 3-wire transmitter power supply 4 VDC power supply 1 kω max. output load 3-way isolation Suitable for Division mounting repeats a 0/4-0 ma signal from a - or 3- wire transmitter in hazardous areas. It also repeats a 0/4-0 ma current source signal. -wire transmitters are connected to terminals 1 and 3 so the 0/4-0 ma transmitter current flows to terminal 3. A minimum of 13.6 V at 0 ma is available between terminals 1 and 3. The power supply is available at terminals 1 and in 3-wire transmitters with the transmitter current flowing to terminal 3. Approximately 16.5 V is available at 5 ma between terminals 1 and for the transmitter. Terminals and 3 are used for connections in applications requiring repeating source currents. This configuration has no terminal 1 connections. A maximum load of 1 kω can be connected between terminals 7 and I VDC Pepperl+Fuchs Inc. Telephone (330) FAX (330)

5 00 IS Catalog Transmitter Power Rail or terminals 11+, VDC 1.7 W Analog Input Transmitters KFD-CR-Ex C - or 3-wire transmitter power supply 4 VDC power supply 1 kω max. output (sink mode) 3-way isolation Suitable for Division mounting repeats the 4-0 ma signal from a - or 3- wire transmitter in hazardous areas. It also repeats a 4-0 ma current source signal. This isolator is specially designed with a sink mode output to work with a Moore Products SAM input card that supplies (sources) current. Two-wire transmitters are connected to terminals 1 and 3 so the 4-0 ma transmitter current flows to terminal 3. A minimum of 13.6 V at 0 ma is available between terminals 1 and 3. The power supply is available on terminals 1 and in 3-wire transmitters with the transmitter current flowing to terminal 3. Approximately 16.5 V is available at 5 ma between terminals 1 and for the transmitter. Terminals and 3 are used for connections in applications requiring repeating source currents. This configuration has no terminal 1 connections. A maximum load of 1 kω can be connected between terminals 8-9. Input (intrinsically safe) Terminals 1+, -, 3 Input 0/4-0 ma (term. 1+, -) 16.5 V at 5 ma (term. 1+, 3) 13.6 V at 0 ma Input resistance (term. -, 3) 0 Ω Output (not intrinsically safe) Terminals 8+, ma Load 1 kω (with 475 Ω external resistor) 0 µa ss ±10 µa nonlinearity, load fluctuations ± 0. µa/ºc range 0-60ºC Rise time 50 µs Entity Parameters Terminals 1+, 3 -, 3 FM control drawing no V 4.4 V 93 ma. ma Terminals 1+, 3 ) 0.14 µf 0.43 µf 1.14 µf ) 4.18 mh mh 34.1 mh Terminals -, 3 ) 1000 µf 3000 µf 8000 µf ) 67.8 mh 39 mh 597 mh *Consult factory for additional certifications and entity parameters 107 x 0 x 115 mm Weight 100 g (3.5 oz.) -0ºC to +60ºC (-4ºF to +140ºF) I 3 Safe Area or Div KFD-CR-Ex C VDC 50 Pepperl+Fuchs Inc. Telephone (330) FAX (330)

6 Analog Input Transmitters 00 IS Catalog Power Rail or terminals 11+, VDC 1.9 W Transmitter Input (intrinsically safe) Terminals 1+, -, 3 Input 0/4-0 ma (term. 1+, -) 16.5 V at 5 ma (term. 1+, 3) 13.6 V at 0 ma Input resistance (term. -, 3) 0 Ω Output (not intrinsically safe) Terminals 7-, 8+, ma 0 VDC Load 1 kω 0 µa ss ±10 µa nonlinearity, load fluctuations ± 0.5 µa / ºC range 0-60ºC Rise time 50 µs Entity Parameters Terminals 1+, -, 3 FM control drawing no V 4.4 V Current I oc 93 ma. ma Terminals 1+, 3 ) 0.14 µf 0.43 µf 1.14 µf ) 4.18 mh mh 34.1 mh Terminals -, 3 ) 1000 µf 3000 µf 8000 µf ) 67.8 mh 39 mh 597 mh 107 x 0 x 115 mm Weight 100 g (3.5 oz.) CSA approvals available upon request -0ºC to +60ºC (-4ºF to +140ºF) Safe Area or Div KFD-CR-Ex KFD-CR-Ex or 3-wire transmitter power supply 4 VDC power supply 4-0 ma input 0-0 ma output Suitable for Division mounting repeats a 4-0 ma signal from a - or 3-wire transmitter in hazardous areas. It also repeats a 4-0 ma current source signal. Two-wire transmitters are connected to terminals 1 and 3 so the 4-0 ma transmitter current flows into terminal 3. A minimum of 13.6 V at 0 ma is available between terminals 1 and 3. The power supply is available on terminals 1 and in 3-wire transmitters with the transmitter current flowing to terminal 3. Approximately 16.5 V is available at 5 ma between terminals 1 and for the transmitter. Terminals and 3 are used for connections in applications requiring repeating source currents. This configuration has no terminal 1 connections. A maximum load of 1 kω can be connected between terminals 8 and I VDC Pepperl+Fuchs Inc. Telephone (330) FAX (330)

7 00 IS Catalog Transmitter Power Rail or terminals 11+, VDC 1.3 W Input (intrinsically safe) Terminals 1+, -, 3 Input signal 0/4-0 ma (term. 1+, -) 15.3 V at 5 ma (term. 1+, 3) 16.8 V at 0 ma Input resistance (term. -, 3) 56 Ω Output (not intrinsically safe) Terminals 7, 8+, 9-, 10+ 0/1-5 V Load kω 5 mv pp Analog Input Transmitters KFD-CV-EX or 3-wire transmitter power supply 0/4-0 ma input 0/1-5 V output Suitable for Division mounting repeats a 0/4-0 ma signal from a - or 3- wire transmitter in hazardous areas and converts it into a voltage output. It also repeats a 0/4-0 ma signal from a current source. Two-wire transmitters are connected to terminals 1 and 3 so the 0/4-0 ma transmitter current flows to terminal 3. A minimum of 16.8 V at 0 ma is available between terminals 1 and 3. The power supply is available on terminals 1 and in 3-wire transmitters with the transmitter current flowing to terminal 3. Approximately 15.3 V is available at 5 ma between terminals 1 and for the transmitter. Terminals and 3 are used for connections in applications requiring repeating source currents. This configuration has no terminal 1 connections. The measurement current is converted into a proportional voltage signal once transmitted to the output. The output circuit has two sets of terminal blocks for the parallel connection of two voltage measurement circuits. The voltage measurement circuits must have a resistance of at least kω. 5 mv 0.005% of span/ ºC Rise time 5. ms Entity Parameters BASEEFA no I 3 Ex 97D085 6 V 93 ma Explosion group II A II B II C ) 0.79 µf 0.97 µf µf ) 33.6 mh 1.6 mh 4. mh 107 x 0 x 115 mm Weight 100 g (3.5 oz.) -0ºC to +60ºC (-4ºF to +140ºF) Safe Area or Div KFD-CV-Ex VDC 0/1-5V 5 Pepperl+Fuchs Inc. Telephone (330) FAX (330)

8 Analog Input Transmitters 00 IS Catalog Power Rail or terminals 11+, VDC 1.3 W Transmitter Input (intrinsically safe) Terminals 1+, -, 3 Input signal 0/4-0 ma (term. 1+, -) 15.3 V at 5 ma (term. 1+, 3) 16.8 V at 0 ma Input resistance (term -, 3) 56 Ω Output (not intrinsically safe) Terminals 7-, 8+, 9-, 10+ 0/-10 V Load kω 10 mv pp Rise time I 3 10 mv ± 0.005% of span/ºc 5. ms Entity Parameters BASEEFA no. Ex 97D085 6 V 93 ma Explosion group IIA IIB IIC Max. external capacitance 0.79 µf 0.97 µf µf Max. external inductance 33.6 mh 1.6 mh 4. mh 107 x 0 x 115 mm Weight 100 g (3.5 oz.) -0ºC to +60ºC (-4ºF to +140ºF) Safe Area or Div KFD-CV-Ex /-10V KFD-CV-Ex or 3-wire transmitter power supply 0/4-4-0 ma input 0/-10 V output Suitable for Division mounting repeats a 0/4-0 ma signal from a - or 3- wire transmitter in hazardous areas and converts it into a voltage output. It also repeats a 0/4-0 ma current source signal. Two-wire transmitters are connected to terminals 1 and 3 so the 0/4-0 ma transmitter current flows to terminal 3. A minimum of 16.8 V at 0 ma is available between terminals 1 and 3. The power supply is available on terminals 1 and in 3- wire transmitters with the transmitter current flowing to terminal 3. Approximately 15.3 V is available at 5 ma between terminals 1 and for the transmitter. Terminals and 3 are used for connections in applications requiring repeating source currents. This configuration has no terminal 1 connections. The measurement current is converted into a proportional voltage of 0/-10 V once transmitted to the output. The output circuit has two sets of terminal blocks to allow the parallel connection of two voltage measurement circuits. The voltage measurement circuits must have a resistance of at least kω VDC Pepperl+Fuchs Inc. Telephone (330) FAX (330)

9 00 IS Catalog Transmitter Power Rail or terminals 11+, VDC 1.6 W Input (intrinsically safe) Terminals 1+, 3- Input signal 4-0 ma 16 VDC at 0 ma Output (not intrinsically safe) Terminals 7-, 8+, ma 0 VDC Load 1 kω 0 µa ss Analog Input Transmitters KFD-CR-Ex wire transmitter power supply 4 VDC power supply 1kΩ max. output load 3-way isolation Special design with low entity parameters Suitable for Division mounting repeats the 4-0 ma signal from a -wire transmitter in hazardous areas. This isolator is specially designed for transmitters with entity parameters less than 8 V. The open circuit voltage of the isolator is 18 V with a minimum of 16 V at 0 ma. The transmitter must be connected to terminals 1 and 3 so the 4-0 ma transmitter current flows into the measurement circuit across terminal 3. A maximum load of 1 kω can be connected between terminals 8-9. ±10 µa nonlinearity, load fluctuations ± 0. µa/ºc range 0-60ºC Rise time 50 µs Entity Parameters Terminals 1+, 3- FM control drawing no V 93 ma ) 0.34 µf 1.01 µf.70 µf ) 4.18 mh mh 34.3 mh 107 x 0 x 115 mm Weight 100 g (3.5 oz.) CSA approvals available upon request -0ºC to +60ºC (-4ºF to +140ºF) Safe Area or Div KFD-CR-Ex VDC 54 Pepperl+Fuchs Inc. Telephone (330) FAX (330)

10 Analog Input Transmitters 00 IS Catalog Power Rail or terminals 11+, VDC 1.7 W Transmitter Input (intrinsically safe) Terminals 1+, -, 3 Input 0/4-0 ma (term. 1+, -) 16.5 V at 5 ma (term. 1+, 3-) 13.6 V at 0 ma Input resistance (term. -, 3) 0 Ω Output (not intrinsically safe) Terminals 8+, ma 0 VDC Load 1 kω 0 µa ss ±10 µa nonlinearity, load fluctuations ± 0. µa/ºc range 0-60ºC Rise time 50 µs Entity Parameters FM control drawing no Terminals 1+, 3 -, 3 1+, -, 3 (V t ) 0 V 4.4 V 0 V (I t ) 93 ma. ma 115 ma Terminals 1+, -, 3 ) 0.34 µf 1.01 µf.70 µf ).65 mh mh.1 mh 107 x 0 x 115 mm Weight 100 g (3.5 oz.) CSA approvals available upon request -0ºC to +60ºC (-4ºF to +140ºF) Safe Area or Div KFD-CR-Ex KFD-CR-Ex or 3-wire transmitter power supply 4 VDC power supply 1 kω max. output load Special design with low entity parameters Suitable for Division mounting repeats a 0-0 ma signal from a - or 3-wire transmitter in hazardous areas. It can also repeat a 0-0 ma signal from a current source. This isolator is specially designed for transmitters with entity parameters of less than 8 V. Two-wire transmitters are connected to terminals 1 and 3 so the 0-0 ma transmitter current flows to terminal 3. A minimum of 1 V at 0 ma exist between terminals 1 and 3. The power supply is available on terminals 1 and in 3-wire transmitters with the transmitter current flowing to terminal 3. Approximately 16 V are available at 5 ma between terminals 1 and for the transmitter. Terminals and 3 are used for connections in applications requiring repeating source currents. This configuration has no terminal 1 connections I Pepperl+Fuchs Inc. Telephone (330) FAX (330)

11 00 IS Catalog SMART Transmitter Power Rail or terminals 7+, VDC 1. W Input (intrinsically safe) Terminals 1+, 3- Input 4-0 ma at 0 ma 16.5 VDC at 0 ma Output (not intrinsically safe) Terminals 9+, 10-, ma, max. load 500 Ω 75 µa ss Analog Input Transmitters KFD-STC1-Ex1 4 VDC power supply SMART communication to 1 khz (-1dB) 4-0 ma output Suitable for Division mounting repeats the 4-0 ma signal from a -wire transmitter inside hazardous area. This isolator can also repeat a maximum 1 khz digital signal that is modulated on the 4-0 ma signal. A processing system, field device or hand-held terminal generates this digital information, which is transferred bidirectionally by the isolator. This allows the operator to interrogate and reprogram the transmitter from a safe area using uncertified communication equipment. Hand-held terminals can be connected as shown in the circuit diagram. These isolators have KF- STP-BU and KF-STP-GN terminals with test probe access holes for the easy interface of hand-held terminals. 10 µa 0.00% of span/ºc Freq. range (50 Ω load) Hazardous area into safe area Band width at 1 ma pp Signal 0 Hz to 1 khz (-1 db) Freq. range (50 Ω load) Safe area into hazardous area Band width at 1 V pp Signal 1 Hz to 1 khz (-1 db) Rise/fall time 40 µs/40 µs Entity Parameters Terminals 1+, 3- FM control drawing no V 93 ma ) 0.14 µf 0.43 µf 1.14 µf ) 4.18 mh mh 34.1 mh 107 x 0 x 115 mm Weight 150 g (5.3 oz.) Safe Area or Div KFD-STC1-Ex1-0ºC to +60ºC (-4ºF to +140ºF) Pepperl+Fuchs Inc. Telephone (330) FAX (330)

12 Analog Input Transmitters 00 IS Catalog Power rail or terminals 7+, VDC 1. W SMART Transmitter Input (intrinsically safe) Terminals 1+, 3- Input 4-0 ma 15.8 V at 0 ma Output (not intrinsically safe) Terminals 9+, 10-, V 75 µa ss 10 µa 0.00% of span/ºc Freq. range (50 Ω load) Hazardous area into safe area Band width at 1 ma pp Signal 0 Hz to 1 khz (-1 db) Freq. range (50 Ω load) Safe area into hazardous area Band width at 1 V pp Signal 1 Hz to 1 khz (-1 db) Rise/fall time 40 µs/40 µs Entity Parameters Terminals 1+, 3- FM control drawing no V 93 ma ) 0.14 µf 0.43 µf 1.14 µf ) 4.18 mh mh 34.1 mh 107 x 0 x 115 mm Weight 150 g (5.3 oz.) -0ºC to +60ºC (-4ºF to +140ºF) Safe Area or Div KFD-STV1-Ex1 KFD-STV1-Ex1 4 VDC power supply SMART communication to 1 khz (-1dB) 1-5 V output Suitable for Division mounting repeats the 4-0 ma signal from a -wire transmitter inside a hazardous area. This 4-0 ma current is converted into a 1-5 V signal. This isolator can also repeat a maximum 1 khz digital signal that is modulated on the 4-0 ma signal. A processing system, field device or hand-held terminal generates this digital information, which is transferred bidirectionally by the isolator. This allows the operator to interrogate and reprogram the transmitter from a safe area using uncertified communication equipment. Hand-held terminals can be connected as shown in the circuit diagram. These isolators have KF-STP- BU and KF-STP-GN terminals with test probe access holes for the easy interface of handheld terminals. Note: Terminal 1 is placed across an internally applied capacitance. Active input cards, such as Foxboro FMB 18, can operate using this connection Pepperl+Fuchs Inc. Telephone (330) FAX (330)

13 00 IS Catalog SMART Transmitter Power rail or terminals 7+, VDC 1.7 W Input (intrinsically safe) Terminals 1+, 3- Input signal 4-0 ma ma Output (not intrinsically safe) Terminals 9+, 10-, ma, max. load 1 kω 0.05% output signal range Analog Input Transmitters KFD-STC3-Ex1 4 VDC supply SMART communication to 40 khz (-1dB) 4-0 ma output 3-way isolation Suitable for Division mounting repeats the 4-0 ma signal from a -wire transmitter inside the hazardous area. This isolator can also repeat a maximum 40 khz digital signal that is modulated on the 4-0 ma signal. A processing system, field device or hand-held terminal generates this digital information, which is transferred bidirectionally by the isolator. This allows the operator to interrogate and reprogram the transmitter from a safe area using uncertified communication equipment. Hand-held terminals can be connected as shown in the circuit diagram. These isolators have KF-STP-BU and KF-STP- GN terminals with test probe access holes for the easy interface of hand-held terminals. 0.05% of output signal 0.00% of span/ºc Freq. range (50 Ω load) Hazardous area into safe area Band width at 1 ma pp Signal 0 Hz to 40 khz (-1 db) Freq. range (50 Ω load) Safe area into hazardous area Band width at 1 V pp Signal 0 Hz to 40 khz (-1 db) Rise/fall time 10 µs/10 µs Entity Parameters Terminals 1+, 3- FM control drawing no V 93 ma ) 0.14 µf 0.43 µf 1.14 µf ) 4.18 mh mh 34.1 mh 107 x 0 x 115 mm Weight 150 g (5.3 oz.) -0ºC to +65ºC (-4ºF to +149ºF) Safe Area or Div KFD-STC3-Ex1 58 Pepperl+Fuchs Inc. Telephone (330) FAX (330)

14 Analog Input Transmitters 00 IS Catalog Power rail or terminals 7+, VDC 1.7 W SMART Transmitter Input (intrinsically safe) Terminals 1+, 3- Input 4-0 ma 16.5 V at 0 ma Output (not intrinsically safe) Terminals 9+, 10-, V, internal resistance 305 Ω 0.05% output signal range Freq. range (50 Ω load) Band width at 1 ma pp Signal Freq. range (50 Ω load) Band width at 1 V pp Signal 0.03% of output signal 0.00% of span/ºc Hazardous area into safe area 0 Hz to 40 khz (-1 db) Safe area into hazardous area 0 Hz to 40 khz (-1 db) Enity Parameters Terminals 1+, 3- FM control drawing no V 93 ma ) 0.14 µf 0.43 µf 1.14 µf ) 4.18 mh mh 34.1 mh 107 x 0 x 115 mm Weight 150 g (5.3 oz.) -0ºC to +65ºC (-4ºF to +149ºF) Safe Area or Div KFD-STV3-Ex1-1 KFD-STV3-Ex1-1 4 VDC supply SMART communication to 40 khz (-1dB) 1-5 V output 3-way isolation Suitable for Division mounting This single channel isolator powers and repeats the 4-0 ma signal from a -wire transmitter inside the hazardous area. This isolator can also repeat a maximum 40 khz digital signal that is modulated on the 4-0 ma signal. A processing system, field device or hand-held terminal generates this digital information, which is transferred bidirectionally by the isolator. This allows the operator to interrogate and reprogram the transmitter from a safe area using uncertified communication equipment. Hand-held terminals can be connected as shown in the circuit diagram. These isolators have KF- STP-BU and KF-STP-GN terminals with test probe access holes for the easy interface of hand-held terminals. Note: Terminal 1 is placed across an internally applied capacitance. Active input cards, such as Foxboro FMB 18, can operate using this connection. Power Rail Connection Pepperl+Fuchs Inc. Telephone (330) FAX (330)

15 00 IS Catalog SMART Transmitter Power rail or terminals 7+, VDC 1.7 W Input (intrinsically safe) Terminals 1+, 3- Input signal 4-0 ma 16.5 V at 0 ma Output (not intrinsically safe) Terminals 10-, 11+, V, internal resistance 305 Ω 0.05% output signal range 0.03% of output signal 0.00% of span/ºc Analog Input Transmitters KFD-STV3-Ex1-4 VDC power supply SMART communication to 40 khz (-1dB) -10 V output 3-way isolation Suitable for Division mounting repeats the 4-0 ma signal from a -wire transmitter inside the hazardous area. This 4-0 ma current is repeated or converted into a or -10 V signal This isolator can also repeat a maximum 40 khz digital signal that is modulated on the 4-0 ma signal. A processing system, field device or hand-held terminal generates this digital information, which is transferred bidirectionally by the isolator. This allows the operator to interrogate and reprogram the transmitter from a safe area using uncertified communication equipment. Hand-held terminals can be connected as shown in the circuit diagram. These isolators have KF- STP-BU and KF-STP-GN terminals with test probe access holes for the easy interface of hand-held terminals. Note: Terminal 1 is placed across an internally applied capacitance. Active input cards, such as Foxboro FMB 18, can operate using this connection. Freq. range (50 Ω load) Hazardous area into safe area Band width at 1 ma pp Signal 0 Hz to 40 khz (-1 db) Safe area into hazardous area Band width at 1 ma pp Signal 0 Hz to 40 khz (-1 db) Rise/fall time 10 µs/10 µs Enity Parameters Terminals 1+, 3- FM control drawing no V 93 ma ) 0.14 µf 0.43 µf 1.14 µf ) 4.18 mh mh 34.1 mh 107 x 0 x 115 mm Weight 150 g (5.3 oz.) -0ºC to +65ºC (-4ºF to +149ºF) Safe Area or Div KFD-STV3-Ex1- Power Rail Connection 60 Pepperl+Fuchs Inc. Telephone (330) FAX (330)

16 Analog Input Transmitters 00 IS Catalog Power Rail or terminals 14+, VDC.5 W HART Transmitter Input (intrinsically safe) Terminals 1+, -, 3 Input 4-0 ma 16 V at 0 ma Output (not intrinsically safe) Terminals 7-, ma Load resistance* Ω 50 µa ss 0 µa 0.00% of span/ºc Freq. range (50 Ω load) Hazardous area into safe area Band width at 1 ma pp Signal 0 Hz to 7.5 khz (-3 db) Freq. range (50 Ω load) Safe area into hazardous area Band width at 1 V pp Signal 300 Hz to 7.5 khz (-3 db) Rise/fall time 0µs/0µs Entity Parameters Terminals 1+, 3- UL control drawing no V 88. ma ) 0.095µF µf.88 µf ) 4. mh 17 mh 33 mh 107 x 0 x 115 mm Weight 100 g (3.5 oz.) -0ºC to +65ºC (-4ºF to +140ºF) Safe Area or Div KFD-STC4-Ex1 KFD-STC4-Ex1 HART compatible 4 VDC power supply 3 way isolation Suitable for Division mounting The SMART transmitter power supplies supply a -wire SMART transmitter within a hazardous area and transfer the analog 4-0 ma signal from the hazardous area to the safe area. Digital signals which can be modulated onto the analog signal, can also be transmitted bidirectionally on the hazardous or safe side. Hand-held terminals can be connected as shown in the block diagram. Hand-held terminals can be connected as shown in the circuit diagram. These isolators have KF-STP-BU and KF-STP- GN terminals with test probe access holes for the easy interface of hand-held terminals. If the communicator is connected in the safe area, the load resistance must not be less than 30 Ω I 3 4-0mA Pepperl+Fuchs Inc. Telephone (330) FAX (330)

17 00 IS Catalog HART Transmitter Power Rail or terminals 14+, VDC.5 W Input (intrinsically safe) Terminals 1+, 3-; 4+, 6- Input 4-0 ma 16 V at 0 ma Output (not intrinsically safe) Terminals 7-, 8+, 10-, ma Load resistance Ω 50 µa ss Analog Input Transmitters KFD-STC4-Ex Dual-channel HART compatible 4 VDC power supply 3 way isolation Suitable for Division mounting The SMART transmitter power supplies supply a -wire SMART transmitter within a hazardous area and transfer the analog 4-0 ma signal from the hazardous area to the safe area. Digital signals which can be modulated onto the analog signal, can also be transmitted bidirectionally on the hazardous or safe side. Handheld terminals can be connected as shown in the block diagram. Hand-held terminals can be connected as shown in the circuit diagram. These isolators have KF-STP-BU and KF-STP-GN terminals with test probe access holes for the easy interface of hand-held terminals. If the communicator is connected in the safe area, the load resistance must not be less than 30 Ω. 0 µa 0.00% of span/ºc Freq. range (50 Ω load) Hazardous area into safe area Band width at 1 ma pp Signal 0 Hz to 7.5 khz (-3 db) Freq. range (50 Ω load) Safe area into hazardous area Band width at 1 V pp Signal 300 Hz to 7.5 khz (-3 db) Rise/fall time 0µs/0µs Entity Parameters Terminals 1, 3; 4, 6 UL control drawing no V 93 ma ) 0.095µF µf.88 µf ) 4. mh 17 mh 33 mh 107 x 0 x 115 mm Weight 100 g (3.5 oz.) -0ºC to +65ºC (-4ºF to +140ºF) Safe Area or Div KFD-STC4-Ex 6 Pepperl+Fuchs Inc. Telephone (330) FAX (330)

18 Analog Input Transmitters 00 IS Catalog Power Rail or terminals 14+, VDC.5 W HART Transmitter Input (intrinsically safe) Terminals 1+, 3-,; 4+, 6- Input 0/4-0 ma 16.0 V at 0 ma Output (not intrinsically safe) Terminals 7-,8+; 10-, 11+ 0/4-0 ma Load resistance Ω 50 µa ss 0 µa 1µA/ºC Freq. range (50 Ω load) Hazardous area into safe area Band width at 1 V pp -Signal 0 Hz to 7.5 khz (-3 db) Freq. range (50 Ω load) Safe area into hazardous area Band width at 1 V pp -Signal 300 Hz to 7.5 khz (-3 db) Entity Parameters Terminals 1, 3, 4, 6 UL control drawing no V 93.0 ma ) 0.093µF µf.808 µf ) 4.6 mh 18 mh 36 mh 107 x 0 x 115 mm Weight 100 g (3.5 oz.) -0ºC to +65ºC (-4ºF to +140ºF) Safe Area or Div KFD-STC4-Ex-Y7195 KFD-STC4-Ex-Y7195 Dual-Channel HART compatible 4 VDC power supply Sink mode output 3-way isolation Suitable for Division mounting The SMART transmitter power supplies supply a -wire SMART transmitter within a hazardous area and transfer the analog 4-0 ma signal from the hazardous area to the safe area. This isolator is designed to provide a sink mode output on the safe area terminals. Digital signals which can be modulated onto the analog signal, can also be transmitted bidirectionally on the hazardous or safe side. Handheld terminals can be connected as shown in the block diagram. The SMART transmitters are normally delivered with the KF-STP-BU and KF-STP- GN terminals. Connector jacks are integrated in these terminals for the connection of the handheld terminals. If the communicator is connected in the safe area, the load resistance must not be less than 30 Ω. 0-35VDC 0-35VDC Pepperl+Fuchs Inc. Telephone (330) FAX (330)

19 I 00 IS Catalog HART Transmitter Power Rail or terminals 14+, VDC.5 W Input (intrinsically safe) Terminals 1+, -, 3 Input signal 4-0 ma (term. 1, 3) 16 V at 0 ma Output (not intrinsically safe) Terminals 7-, 8+, 10-, ma Load resistance* Ω 75 µa pp Analog Input Transmitters KFD-STC4-Ex1.0 Dual outputs HART compatible 4-0mA current source outputs 3-way isolation SMART transmitter power supplies supply a -wire SMART transmitter within a hazardous area and transfer the analog 4-0 ma signal from the hazardous area to the safe area as two current sources. Digital signals which can be modulated onto the analog signal, can also be transmitted bidirectionally on the hazardous or safe side. Handheld terminals can be connected as shown in the block diagram. The SMART transmitters are normally delivered with the KF-STP-BU and KF-STP- GN terminals. Connector jacks are integrated in these terminals for the connection of the handheld terminals. If the communicator is connected in the safe area, the load resistance must not be less than 30 Ω. 0 µa 1 µa/ºc Freq. range (50 Ω load) (Hazardous area into safe area) Band width at 0.5 V pp Signal 0 Hz to 7.5 khz (-3 db) (Safe area into hazardous area) Band width at 0.5 V pp Signal 300 Hz to 7.5 khz (-3 db) Interference rejection Unaffected by 60 V, 50 Hz common mode input signal with any safe side terminal grounded, and 7 MHz walkie-talkies Entity Parameters Terminals 1+, 3- UL control drawing no V 88. ma ) 0.01 µf µf.89 µf ) 4. mh 17 mh 33 mh 107 x 0 x 115 mm Weight 100 g (3.5 oz.) -0ºC to +60ºC (-4ºF to +140ºF ) Safe Area or Div KFD-STC4-Ex VDC 64 Pepperl+Fuchs Inc. Telephone (330) FAX (330)

20 I Analog Input Transmitters 00 IS Catalog Power Rail or terminals 14+, VDC.5 W HART Transmitter Input (intrinsically safe) Terminals 1+, -, 3 Input signal 4-0 ma (term. 1, 3) 16 V at 0 ma Output (not intrinsically safe) Terminals 7-, 8+, 10-, ma Load resistance* Ω 75 µa pp 0 µa 1 µa/ºc Freq. range (50 Ω load) (Hazardous area into safe area) Band width at 0.5 V pp Signal 0 Hz to 7.5 khz (-3 db) (Safe area into hazardous area) Band width at 0.5 V pp Signal 300 Hz to 7.5 khz (-3 db) Interference rejection Unaffected by 60 V, 50 Hz common mode input signal with any safe side terminal grounded, and 7 MHz walkie-talkies Entity Parameters Terminals 1+, 3- UL control drawing no V 88. ma ) 0.01 µf µf.89 µf ) 4. mh 17 mh 33 mh 107 x 0 x 115 mm Weight 100 g (3.5 oz.) -0ºC to +60ºC (-4ºF to +140ºF ) KFD-STC4-Ex1.0-Y716 Dual outputs HART compatible Sink mode outputs 3-way isolation SMART transmitter power supplies supply a -wire SMART transmitter within a hazardous area and transfer the analog 4-0 ma signal from the hazardous area to the safe area as two current sink outputs. Digital signals which can be modulated onto the analog signal, can also be transmitted bidirectionally on the hazardous or safe side. Handheld terminals can be connected as shown in the block diagram. The SMART transmitters are normally delivered with the KF-STP-BU and KF-STP- GN terminals. Connector jacks are integrated in these terminals for the connection of the handheld terminals. Safe Area or Div KFD-STC4-Ex1.0-Y716 If the communicator is connected in the safe area, the load resistance must not be less than 30 Ω VDC VDC VDC Pepperl+Fuchs Inc. Telephone (330) FAX (330)

SAFETY MANUAL SIL SMART Transmitter Power Supply

SAFETY MANUAL SIL SMART Transmitter Power Supply PROCESS AUTOMATION SAFETY MANUAL SIL SMART Transmitter Power Supply KFD2-STC4-(Ex)*, KFD2-STV4-(Ex)*, KFD2-CR4-(Ex)* ISO9001 2 3 With regard to the supply of products, the current issue of the following

More information

SINEAX SI 815 Passive DC Signal Isolator

SINEAX SI 815 Passive DC Signal Isolator with power supply transfer and without separate power supply connection, versions available for FSK 1 and Ex and non-ex, in housing N17 or S17 for rail and wall mounting 0102 II (1) G Application The signal

More information

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V

More information

Analog signal converters CC-E I/I Current / current isolators

Analog signal converters CC-E I/I Current / current isolators ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between

More information

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give

More information

Contents. Document information

Contents. Document information User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB

More information

SIRAX SI 815 Passive DC Signal Isolator

SIRAX SI 815 Passive DC Signal Isolator with power supply transfer and without separate power supply connection, versions available for FSK, Ex and non-ex versions 002 II () G Application The signal isolator SIRAX SI 85 (Fig. ) serves to electrically

More information

Assembly. Front view. Switch S1. Power Rail

Assembly. Front view. Switch S1. Power Rail Temperature Repeater Features Assembly 1-channel isolated barrier V DC supply (Power Rail) Resistance and RTD input (Pt100, Pt500, Pt1000) Resistance output Accuracy 0.1 % Line fault detection (LFD) for

More information

Description. Specifications All Specifications are at 23 C ± 2 C, (73.4 F ± 3.6 F)

Description. Specifications All Specifications are at 23 C ± 2 C, (73.4 F ± 3.6 F) Specifications and Ordering Information 1701/06 FieldMonitor Isolator Terminal Base and 170190 Dual Galvanic Isolator for Hazardous Areas Description The 1701/06 Isolator Terminal Base (ITB) and 170190

More information

Rosemount 333 HART Tri-Loop

Rosemount 333 HART Tri-Loop Product Data Sheet Rosemount 333 Rosemount 333 HART Tri-Loop HART-TO-ANALOG SIGNAL CONVERTER Convert a digital HART signal into three additional analog signals Easy to configure and install Accessory product

More information

Safety Barriers Series 9001, 9002 Standard Applications

Safety Barriers Series 9001, 9002 Standard Applications Standard s Analog input with transmitter Smart Field circuit grounded 9001/51-80-091-141 09949E0 Load of transmitter U N = + 0 V... 35 V I N = 3.6 ma... ma R L ( 350 O U min (I N= 0 ma) U N - 9.5 V 14

More information

MINI MCR-SL-UI-UI-NC. Extract from the online catalog. Order No.:

MINI MCR-SL-UI-UI-NC. Extract from the online catalog. Order No.: Extract from the online catalog MINI MCR-SL-UI-UI-NC Order No.: 2864150 MCR 3-way isolating amplifier for electrical isolation of analog signals, input/output configurable via DIP switch, with screw connection,

More information

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply

More information

T9 / R9. Long Range RF Modules. Features. Applications. General Description

T9 / R9. Long Range RF Modules. Features. Applications. General Description T9 / R9 Long Range RF Modules Features FM Narrow Band Crystal Stabilised Range up to 1,000 Metres 868MHz / 433MHz Versions 4 channel versions 434.075MHz 433.920MHz 434.225MHz 434.525MHz Miniature SIL Package

More information

US-SPI New generation of High performances Ultrasonic device

US-SPI New generation of High performances Ultrasonic device US-SPI New generation of High performances Ultrasonic device Lecoeur Electronique - 19, Rue de Courtenay - 45220 CHUELLES - Tel. : +33 ( 0)2 38 94 28 30 - Fax : +33 (0)2 38 94 29 67 US-SPI Ultrasound device

More information

Programmable Temperature Transmitter Model : T700C

Programmable Temperature Transmitter Model : T700C f Programmable Temperature Transmitter Model : T700C Advantages Two wire 4~20mA Loop powered design Universal input signals RTD temperature sensor T/C elements Mv, V, ma DC signals Programmable function

More information

PIN CONFIGURATION FEATURES ORDERING INFORMATION ABSOLUTE MAXIMUM RATINGS. D, F, N Packages

PIN CONFIGURATION FEATURES ORDERING INFORMATION ABSOLUTE MAXIMUM RATINGS. D, F, N Packages DESCRIPTION The µa71 is a high performance operational amplifier with high open-loop gain, internal compensation, high common mode range and exceptional temperature stability. The µa71 is short-circuit-protected

More information

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter Description: The NTE2053 is a CMOS 8 bit successive approximation Analog to Digital converter in a 20 Lead DIP type package which uses a differential

More information

Differential Charge Amplifier

Differential Charge Amplifier Electronics Differential Type 58A... The differential charge amplifier is used for signal conversion of piezoelectric sensors with differential output. Executions Aluminum die-cast enclosure (IP64) Plastic

More information

Rosemount 333 HART Tri-Loop

Rosemount 333 HART Tri-Loop Product Data Sheet September 2014 00813-0100-4754, Rev GA Rosemount 333 HART Tri-Loop HART-to-Analog Signal Converter Convert a digital HART signal into three additional analog signals Easy to configure

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

Features. Applications. Transmitter. Receiver. General Description MINIATURE MODULE. QM MODULATION OPTIMAL RANGE 1000m

Features. Applications. Transmitter. Receiver. General Description MINIATURE MODULE. QM MODULATION OPTIMAL RANGE 1000m Features MINIATURE MODULE QM MODULATION OPTIMAL RANGE 1000m 433.05 434.79 ISM BAND 34 CHANNELS AVAILABLE SINGLE SUPPLY VOLTAGE Applications IN VEHICLE TELEMETRY SYSTEMS WIRELESS NETWORKING DOMESTIC AND

More information

Technical Note Series

Technical Note Series Technical Note Series SKIN CONDUCTANCE SENSOR (SA9309M) S TN0 0 0 8-0 0 S k i n C o n d u c t a n c e S e n s o r Page 2 IMPORTANT OPERATION INFORMATION WARNING Type BF Equipment Internally powered equipment

More information

+5 V Powered RS-232/RS-422 Transceiver AD7306

+5 V Powered RS-232/RS-422 Transceiver AD7306 a FEATURES RS- and RS- on One Chip Single + V Supply. F Capacitors Short Circuit Protection Excellent Noise Immunity Low Power BiCMOS Technology High Speed, Low Skew RS- Operation C to + C Operations APPLICATIONS

More information

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** FM 3046039 Class I Div 1, Groups A, B, C and D Class II Div 1, Groups E, F and G; Class III Class I, Zone 0, AEx ia IIC Ga, Ga/Gb, Gb Document ID:

More information

Supply unit for transmitters

Supply unit for transmitters JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

200350 and 200355 Accelerometers

200350 and 200355 Accelerometers and Accelerometers Bently Nevada Asset Condition Monitoring Description The and Accelerometers are general purpose, casemounted seismic transducers designed for use with Trendmaster Pro Constant Current

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex Data Sheet 0/-8.5 EN FieldIT Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit)

More information

US-Key New generation of High performances Ultrasonic device

US-Key New generation of High performances Ultrasonic device US-Key New generation of High performances Ultrasonic device US-Key connected to a laptop computer US-Key Ultrasound device single channel Features USB2 High Speed connection Ultralow noise preamplifier

More information

MINI MCR-SL-R-UI(-SP)

MINI MCR-SL-R-UI(-SP) Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts

More information

Features. Ordering Information. * Underbar marking may not be to scale. Part Identification

Features. Ordering Information. * Underbar marking may not be to scale. Part Identification MIC86 Teeny Ultra Low Power Op Amp General Description The MIC86 is a rail-to-rail output, input common-mode to ground, operational amplifier in Teeny SC7 packaging. The MIC86 provides 4kHz gain-bandwidth

More information

Voltage Measuring Transducer for AC Voltage MCR-VAC-UI-0-DC

Voltage Measuring Transducer for AC Voltage MCR-VAC-UI-0-DC , Voltage Measuring Transducer for AC Voltage MCR-VAC-UI-0-DC. Description -way electrical isolation TRMS measurement Adjustable voltage ranges / adjustment ±0% Voltage transducers measure AC voltages

More information

Precision, Unity-Gain Differential Amplifier AMP03

Precision, Unity-Gain Differential Amplifier AMP03 a FEATURES High CMRR: db Typ Low Nonlinearity:.% Max Low Distortion:.% Typ Wide Bandwidth: MHz Typ Fast Slew Rate: 9.5 V/ s Typ Fast Settling (.%): s Typ Low Cost APPLICATIONS Summing Amplifiers Instrumentation

More information

Application Note TMA Series

Application Note TMA Series 1W, SIP, Single & Dual Output DC/DC Converters Features SIP Package with Industry Standard Pinout Package Dimension: 19.5 x 10.2 x 6.1 mm (0.77 x 0.4 x 0.24 ) 5V&12V Models 19.5 x 10.2 x 7.1 mm (0.77 x

More information

JUMPFLEX 857 Series. 0...20 ma 2...10 V. 4...20 ma. Transducers / Relay and Optocoupler Modules

JUMPFLEX 857 Series. 0...20 ma 2...10 V. 4...20 ma. Transducers / Relay and Optocoupler Modules 0888-0172/0002-3601 JUMPFLEX 857 Series 2.0 E 12/08 Printed in Germany Subject to design changes 2...10 V 0...20 ma 4...20 ma WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 32385 Minden Hansastraße 27

More information

NTE923 & NTE923D Integrated Circuit Precision Voltage Regulator

NTE923 & NTE923D Integrated Circuit Precision Voltage Regulator NTE923 & NTE923D Integrated Circuit Precision Voltage Regulator Description: The NTE923 and NTE923D are voltage regulators designed primarily for series regulator applications. By themselves, these devices

More information

3500/40M Proximitor* Monitor

3500/40M Proximitor* Monitor 3500/40M Proximitor* Monitor Bently Nevada* Asset Condition Monitoring Description The 3500/40M Proximitor Monitor is a 4-channel monitor that accepts input from Bently Nevada proximity transducers, conditions

More information

Proximity Transmitters and Seismic Vibration Transmitters

Proximity Transmitters and Seismic Vibration Transmitters Proximity Transmitters and Seismic Vibration Transmitters TR1101 Seismic Vibration Transmitter The TR1101 is a cost-effective solution for monitoring case vibration on balance of plant machines. The TR1101

More information

Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL

Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL WARNING: READ AND UNDERSTAND THIS MANUAL BEFORE USING YOUR MULTIMETER. FAILURE TO UNDERSTAND AND COMPLY WITH WARNINGS AND OPERATING INSTRUCTIONS

More information

css Custom Silicon Solutions, Inc.

css Custom Silicon Solutions, Inc. css Custom Silicon Solutions, Inc. CSS555(C) CSS555/ PART DESCRIPTION The CSS555 is a micro-power version of the popular 555 Timer IC. It is pin-for-pin compatible with the standard 555 timer and features

More information

GT Sensors Precision Gear Tooth and Encoder Sensors

GT Sensors Precision Gear Tooth and Encoder Sensors GT Sensors Precision Gear Tooth and Encoder Sensors NVE s GT Sensor products are based on a Low Hysteresis GMR sensor material and are designed for use in industrial speed applications where magnetic detection

More information

DC Electronic Loads 8500 series

DC Electronic Loads 8500 series Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating

More information

AutoRanging Digital MultiMeter

AutoRanging Digital MultiMeter Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

Features. Modulation Frequency (khz) VDD. PLL Clock Synthesizer with Spread Spectrum Circuitry GND

Features. Modulation Frequency (khz) VDD. PLL Clock Synthesizer with Spread Spectrum Circuitry GND DATASHEET IDT5P50901/2/3/4 Description The IDT5P50901/2/3/4 is a family of 1.8V low power, spread spectrum clock generators capable of reducing EMI radiation from an input clock. Spread spectrum technique

More information

High Common-Mode Rejection. Differential Line Receiver SSM2141. Fax: 781/461-3113 FUNCTIONAL BLOCK DIAGRAM FEATURES. High Common-Mode Rejection

High Common-Mode Rejection. Differential Line Receiver SSM2141. Fax: 781/461-3113 FUNCTIONAL BLOCK DIAGRAM FEATURES. High Common-Mode Rejection a FEATURES High Common-Mode Rejection DC: 00 db typ 60 Hz: 00 db typ 20 khz: 70 db typ 40 khz: 62 db typ Low Distortion: 0.00% typ Fast Slew Rate: 9.5 V/ s typ Wide Bandwidth: 3 MHz typ Low Cost Complements

More information

FM Radio Transmitter & Receiver Modules

FM Radio Transmitter & Receiver Modules FM Radio Transmitter & Receiver Modules T5 / R5 Features MINIATURE SIL PACKAGE FULLY SHIELDED DATA RATES UP TO 128KBITS/S RANGE UPTO 300 METRES SINGLE SUPPLY VOLTAGE INDUSTRY PIN COMPATIBLE QFMT5-434 TEMP

More information

OMNIYIG. .5 TO 2 GHz, 1 TO 4 GHz, 6 to 18 GHz Thin Film YIG-TUNED OSCILLATORS OUTLINE DIMESIONS MOUNTING SURFACE GND +15V + TUNE - HTR HTR

OMNIYIG. .5 TO 2 GHz, 1 TO 4 GHz, 6 to 18 GHz Thin Film YIG-TUNED OSCILLATORS OUTLINE DIMESIONS MOUNTING SURFACE GND +15V + TUNE - HTR HTR . TO Hz, 1 TO Hz, to 1 Hz Thin Film YITUNED OSCILLATORS Highly Reliable StateoftheArt ThinFilm Technology s. to 1 Hz oscillators employ thinfilm technology, coupled with aas FET transistors, and were designed

More information

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented

More information

SPECIAL NOTICE. All references to NAT product part numbers (and associated images) are equivalent to AEM product part numbers.

SPECIAL NOTICE. All references to NAT product part numbers (and associated images) are equivalent to AEM product part numbers. SPECIAL NOTICE This product is now licensed to Anodyne Electronics Manufacturing (AEM) from Northern Airborne Technology (NAT). AEM is responsible for all matters related to this product, including sales,

More information

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope) OBSOLETE NMPD0 Series SELECTION GUIDE Order Code Nominal Input Voltage Output Voltage Efficiency (Min.) Power (Max.) V V % W NMPD003C 3. 9.50 NMPD005C 5. 9.5 NMPD0C. 0 0.00 NMPD05C 5. 9 0.00 FEATURES RoHS

More information

350500 Dynamic Pressure Charge Amplifier

350500 Dynamic Pressure Charge Amplifier 350500 Dynamic Pressure Charge Amplifier Bently Nevada* Asset Condition Moniting Description The 350500 Dynamic Pressure Charge Amplifier (DPCA) is a component in a dynamic pressure sensing system. This

More information

Wahl C50 Calibrator FEATURES

Wahl C50 Calibrator FEATURES NEW! On Site Multifunction Portable Far Superior Accuracy as Compared to Fluke! Simultaneous Measurement and Generation Quick Connect Terminals Anti-Shock Boot Quick Connect Terminals Navigator Power Supply,

More information

IrDA Transceiver with Encoder/Decoder

IrDA Transceiver with Encoder/Decoder PRELIMINARY IrDA Transceiver with Encoder/Decoder FEATURES Micropower in the Sleep Mode, (2µA) 3V to 5V Operation Wide Dynamic Receiver Range from 200nA to 50mA Typical Direct Interface to IrDA Compatible

More information

HT9170 DTMF Receiver. Features. General Description. Selection Table

HT9170 DTMF Receiver. Features. General Description. Selection Table DTMF Receiver Features Operating voltage: 2.5V~5.5V Minimal external components No external filter is required Low standby current (on power down mode) General Description The HT9170 series are Dual Tone

More information

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461 D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

FM TRANSMITTER & RECEIVER HYBRID MODULES. FM-RTFQ SERIES FM-RRFQ SERIES. Transmitter. Receiver. Applications

FM TRANSMITTER & RECEIVER HYBRID MODULES. FM-RTFQ SERIES FM-RRFQ SERIES. Transmitter. Receiver. Applications FM Radio Transmitter & Receivers Available as or or 868MHz Transmit Range up to 20m Miniature Packages Data Rate up to 9.6Kbps No Adjustable Components Very Stable Operating Frequency Operates from 20

More information

Screw-in RTD temperature probe with plug connector according to DIN EN 175301

Screw-in RTD temperature probe with plug connector according to DIN EN 175301 ata sheet 902044 Page 1/8 Screw-in RT temperature probe with plug connector according to IN EN 175301 For temperatures between -50 and +260 C Vibration-resistant design Plug connector locked against contact,

More information

Description. Specifications. Specifications and Ordering Information 3500/63 Hazardous Gas Monitor. Inputs

Description. Specifications. Specifications and Ordering Information 3500/63 Hazardous Gas Monitor. Inputs Specifications and Ordering Information 3500/63 Hazardous Gas Monitor doghouses are all examples of confined spaces where combustible gases could accumulate. Description The 3500/63 Hazardous Gas Monitor

More information

PowerAmp Design. PowerAmp Design PAD135 COMPACT HIGH VOLATGE OP AMP

PowerAmp Design. PowerAmp Design PAD135 COMPACT HIGH VOLATGE OP AMP PowerAmp Design COMPACT HIGH VOLTAGE OP AMP Rev G KEY FEATURES LOW COST SMALL SIZE 40mm SQUARE HIGH VOLTAGE 200 VOLTS HIGH OUTPUT CURRENT 10A PEAK 40 WATT DISSIPATION CAPABILITY 200V/µS SLEW RATE APPLICATIONS

More information

Objective. To design and simulate a cascode amplifier circuit using bipolar transistors.

Objective. To design and simulate a cascode amplifier circuit using bipolar transistors. ascode Amplifier Design. Objective. o design and simulate a cascode amplifier circuit using bipolar transistors. Assignment description he cascode amplifier utilises the advantage of the common-emitter

More information

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D ELECTRONICS AB DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & 800Vpp&60mA& 100x& DC&to&ca&200&kHz & LOW&OUTPUT&IMPEDANCE& HIGH&SLEW&RATE &

More information

SINEAX VK 616 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX VK 616 Programmable Temperature Transmitter for RTD and TC inputs SINEAX VK 66 for installation in the terminal head of a temperature sensor DIN 79, Shape B 00 II () G Application SINEAX VK 66 is a two-wire head-mounted transmitter. It is designed for measuring temperature

More information

CAN Bus Transceivers Operate from 3.3V or 5V and Withstand ±60V Faults

CAN Bus Transceivers Operate from 3.3V or 5V and Withstand ±60V Faults CAN Bus Transceivers Operate from 3.3V or 5V and Withstand ±6 Faults Ciaran Brennan design features The LTC2875 is a robust CAN bus transceiver that features ±6 overvoltage and ±25kV ESD tolerance to reduce

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature

More information

DeltaV S-series Traditional I/O

DeltaV S-series Traditional I/O DeltaV Distributed Control System Product Data Sheet DeltaV S-series Traditional I/O Modular and flexible construction. Reduced installation time and expense. Easy online expansion. Field mounted capable

More information

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404 /, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,

More information

HDO700 P FIBRE OPTIC TRANSMITTER

HDO700 P FIBRE OPTIC TRANSMITTER Timo Rantanen 18.1.2011 1(5) HDO700 P FIBRE OPTIC TRANSMITTER HDO700 P is a high performance, extremely linear externally modulated 1550 nm transmitter for HDO fibre optic CATV link. This transmitter type

More information

Dual Channel SiC MOSFET Driver

Dual Channel SiC MOSFET Driver Dual Channel SiC MOSFET Driver Gate Driver for 1200V, 62mm SiC MOSFET Power Module Features 2 output channels Integrated isolated power supply Direct mount low inductance design Short circuit protection

More information

Advanced Monolithic Systems

Advanced Monolithic Systems Advanced Monolithic Systems FEATURES Three Terminal Adjustable or Fixed oltages* 1.5, 1.8, 2.5, 2.85, 3.3 and 5. Output Current of 1A Operates Down to 1 Dropout Line Regulation:.2% Max. Load Regulation:.4%

More information

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations Addendum to: IMPULSE G+ Series 3 Manual (140-10258) IMPULSE VG+ Series 3 Manual (140-10257) This addendum should be used when a 24VDC

More information

PROCESS AUTOMATION FLEXIBLE ASSET MANAGEMENT HART INTERFACE SOLUTIONS

PROCESS AUTOMATION FLEXIBLE ASSET MANAGEMENT HART INTERFACE SOLUTIONS PROCESS AUTOMATI FLEXIBLE ASSET MANAGEMENT HART INTERFACE SOLUTIS Pepperl+Fuchs Elcon The Leader In Intrinsic Safety And HART Interface Solutions The HART interface solutions (HIS) family of products from

More information

TRIPLE PLL FIELD PROG. SPREAD SPECTRUM CLOCK SYNTHESIZER. Features

TRIPLE PLL FIELD PROG. SPREAD SPECTRUM CLOCK SYNTHESIZER. Features DATASHEET ICS280 Description The ICS280 field programmable spread spectrum clock synthesizer generates up to four high-quality, high-frequency clock outputs including multiple reference clocks from a low-frequency

More information

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one. 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter

More information

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A 6ES7314-6CG03-0AB0 Page 1 Product data sheet 6ES7314-6CG03-0AB0 SIMATIC S7-300, CPU 314C-2DP COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), INTEGRATED DP INTERFACE, INTEGRATED

More information

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component. Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on

More information

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry

More information

4N25 Phototransistor Optocoupler General Purpose Type

4N25 Phototransistor Optocoupler General Purpose Type 4N Phototransistor Optocoupler General Purpose Type Data Sheet Lead (Pb) Free RoHS 6 fully compliant RoHS 6 fully compliant options available; -xxxe denotes a lead-free product Description The 4N is an

More information

1 pc Charge Injection, 100 pa Leakage CMOS 5 V/5 V/3 V 4-Channel Multiplexer ADG604

1 pc Charge Injection, 100 pa Leakage CMOS 5 V/5 V/3 V 4-Channel Multiplexer ADG604 a FEATURES 1 pc Charge Injection (Over the Full Signal Range) 2.7 V to 5.5 V ual Supply 2.7 V to 5.5 ingle Supply Automotive Temperature Range: 4 C to +125 C 1 pa Max @ 25 C Leakage Currents 85 Typ On

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel. +45 7547 0600 vc@valcontrols.com www.valcontrols.

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel. +45 7547 0600 vc@valcontrols.com www.valcontrols. HARDWARE MANUAL Ixx24-A 1/20 Table of contents 1 General... 3 1.1 Safety instructions... 3 1.2 Environment... 3 1.3 Mounting and dimension... 3 2 Communication... 4 2.1 Control loop AI0 and Transmitter

More information

Transmitter TEMPERATURE HEAD TRANSMITTER. Series 440 Programmable RTD Temperature Transmitter. Features and Benefits. Application Areas TT-1

Transmitter TEMPERATURE HEAD TRANSMITTER. Series 440 Programmable RTD Temperature Transmitter. Features and Benefits. Application Areas TT-1 Series 440 Programmable RTD Temperature Transmitter TEMPERATURE HEAD TRANSMITTER Application Areas Features and Benefits Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036

More information

High-Speed, 5 V, 0.1 F CMOS RS-232 Driver/Receivers ADM202/ADM203

High-Speed, 5 V, 0.1 F CMOS RS-232 Driver/Receivers ADM202/ADM203 a FEATURES kb Transmission Rate ADM: Small (. F) Charge Pump Capacitors ADM3: No External Capacitors Required Single V Power Supply Meets EIA-3-E and V. Specifications Two Drivers and Two Receivers On-Board

More information

FEATURES DESCRIPTION APPLICATIONS BLOCK DIAGRAM. PT2248 Infrared Remote Control Transmitter

FEATURES DESCRIPTION APPLICATIONS BLOCK DIAGRAM. PT2248 Infrared Remote Control Transmitter Infrared Remote Control Transmitter DESCRIPTION PT2248 is an infrared remote control transmitter utilizing CMOS Technology. It is capable of 18 functions and a total of 75 commands. Single-shot and continuous

More information

F 6214: 4-channel analog input module

F 6214: 4-channel analog input module F 6214 F 6214: 4-channel analog input module safety-related, applicable up to SIL 3 according to IEC 61508 for transmitters in two-wire technology 4...20 ma voltage inputs 0...1/5/10 V current inputs 0...20

More information

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit

More information

TXR/TXA TRENDSETTER Datasheet

TXR/TXA TRENDSETTER Datasheet TXR/TXA TRENDSETTER Datasheet SPECIFICATIONS Unless otherwise noted, all specifications are specified at 21 C (70 F), +24 Vdc power supply, gap set to 1.27 mm (50 mils) and using Metrix AISI 4140 steel

More information

User's Guide. True RMS Industrial Multimeter

User's Guide. True RMS Industrial Multimeter User's Guide 97650 True RMS Industrial Multimeter Ω C ã F ã 10A V µ 10A V ã ã ma A Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

CX133 Zone Mixer Installation & User Guide V9.0

CX133 Zone Mixer Installation & User Guide V9.0 CX133 Zone Mixer Installation & User Guide V9.0 Cloud Electronics Limited 140 Staniforth Road, Sheffield, S9 3HF England Tel + 44 (0) 114 244 7051 Fax + 44 (0) 114 242 5462 E-mail info@cloud.co.uk Web

More information

TS321 Low Power Single Operational Amplifier

TS321 Low Power Single Operational Amplifier SOT-25 Pin Definition: 1. Input + 2. Ground 3. Input - 4. Output 5. Vcc General Description The TS321 brings performance and economy to low power systems. With high unity gain frequency and a guaranteed

More information

Doc. CC-0007 FOR MOSFET OR IGBT CONTROL, SCR TRIGGERING, DC/DC CONVERSION POWER LINE COMMUNICATION COUPLING TRANSFORMERS

Doc. CC-0007 FOR MOSFET OR IGBT CONTROL, SCR TRIGGERING, DC/DC CONVERSION POWER LINE COMMUNICATION COUPLING TRANSFORMERS PRODUCT INDEX FLYBACK TRANSFORMERS RANGE TRANSFORMERS/CONTROL CIRCUITS CROSS REFERENCE LIST 1 TO 9 W EE 16 74090 74091 74092 74093 74094 74095 1 TO 6 W EE 16 74000 74001 74002 74003 6 TO 12 W EE 16 74010

More information

MODEL IFMA - DIN-RAIL FREQUENCY TO ANALOG CONVERTER

MODEL IFMA - DIN-RAIL FREQUENCY TO ANALOG CONVERTER Bulletin No. IFMA-E Drawing No. LP0340 Released 5/06 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL IFMA - DIN-RAIL FREQUENCY TO ANALOG CONVERTER SIMPLE ON-LINE RANGE SETTING (Using

More information

SELECTION GUIDE. Nominal Input

SELECTION GUIDE. Nominal Input www.murata-ps.com NKE Series FEATURES RoHS Compliant Sub-Miniature SIP & DIP Styles 3kVDC Isolation UL Recognised Wide Temperature performance at full 1 Watt load, 40 C to 85 C Increased Power Density

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals

More information

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution

More information

Installation Guide - Alarm Module T941AM8

Installation Guide - Alarm Module T941AM8 Alarm Module T9AM Installation Guide - Alarm Module T9AM T9AM has physical inputs for connection to external alarm devices. Inputs are galvanically isolated, have transient protection, and can be programmed

More information

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement. and Transmitter All-in-one package for open channel flow measurement. 3.1 NEW Class 1, Division 1 Approved Sensor As our products are continuously improved, we reserve the right to make any change in the

More information