1 This is to signify that PROMPT ENGINEERING & TRADING SERVICES CO. W.L.L P.O. BOX BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR Calibration Laboratory CL-165 has met the requirements of the IAS Accreditation Criteria for Calibration Laboratories (AC204), has demonstrated compliance with the ISO/IEC Standard 17025:2005, General requirements for the competence of testing and calibration laboratories, and has been accredited commencing, for the calibration discipline(s) listed in the approved scope of accreditation. The laboratory meets IAS program requirements in the field of calibration. Patrick V. McCullen Vice, Chief Technical Officer (see attached scope of accreditation for fields of calibration and accredited calibration methods) Print Date: 1/13/2015 Page 1 of 10

2 Prompt Engineering & Trading Services CO. W.L.L Ferdinand D. Borlongan P.O. Box Calibration / Quality Manager Barwa Village, Wakra, Building No. 6, Shop No. 19 and Doha Qatar AREA CAPABILITY 1 STANDARD, EQUIPMENT (CMC) (±) MECHANICAL Dimensional External Micrometer mm/0.01 mm mm/0.001 mm 6.05 µm 1.92 µm Using slip gauge set, optical parallel and optical flat Using Slip gauge set Caliper (Vernier/Dial/Electronics) mm/0.01 mm mm/0.02 mm 8.97 µm µm Using slip gauge set Using slip gauge set Height Gauge mm/0.01 mm mm/0.02 mm µm µm Using surface plate, slip gauge set and length bars Thickness Gauge 0 5 mm/0.001 mm 1.0 µm Using Slip gauge set 0 25 mm/0.01 mm 5.93 µm Using Slip gauge set 0 50 mm/0.01 mm 5.93 µm Using Slip gauge set Feeler Gauge mm 2.69 µm Using Digital Micrometer Standard Foils Up to 5000 m 2.63 µm Using Digital Micrometer Pressure (Pneumatic) Pressure and Vacuum Gauge (Dial/Digital) and Recorder/Pressure Transducer/Safety Valve 1 to 120 bar/0.01 bar 0.57% FS Using DH Budenberg P542 pneumatic calibrator (N 2 gas) Pressure and Vacuum Gauge (Dial/Digital) and Recorder/Pressure Transducer/Safety Valve 1 to 200 bar/0.01 bar 0.57% FS Fluke P M Comparator with Reference pressure gauge, Fluke 2700G G20M Pressure (Hydraulic) Pressure Gauge (Dial/Digital) and Recorder Pressure Transducer 0 to 140 bar/0.01 bar 140 to 1200 bar/0.1bar 0.39% FS Using DH Budenberg H542/409 hydraulic Deadweight Tester Print Date: 1/13/2015 Page 2 of 10

3 AREA MECHANICAL (continued) Vibration Vibration Meter/Analyzer Acoustic At Laboratory Sound Level Meter 10 m/s 2 NA 94 db and 1kHz NA CAPABILITY 1 (CMC) (±) 0.38 m/s db TECHNIQUE, REFERENCE STANDARD, EQUIPMENT Using Calibration exciter Type 4294, Bruel and Kjaer Make Using Cirrus research CR511F and CR514 acoustic calibrator Sound Level Calibrator 94 db and 114 1kHz, 0.1 db 1.37 db Using Cirrus CR306 sound level meter Velocity At Laboratory Hot Wire, Vane Type and Pitot Tube Anemometer THERMAL Temperature Controller/Indicator/Recorder/ with Sensor/Thermometer/Thermocouple/RTD Sensor/Temperature Gauge/Transmitter 2.5 m/s to 15 m/s 0.1 m/s 25 C to 150 C/0.001 C Using Vane anemometer: 0.55 m/s@15 m/s Using Pitot: 0.47 m/s@15 m/s 0.25C Using WTM 1000, Laboratory grade, Bench top mini wind tunnel, Omega make and reference anemometer and reference pitot tube Using FLUKE 9142 temperature calibrator with FLUKE 5615 PRT secondary standard Infrared Thermometer -15 C to 120 C/ 0.7C Using FLUKE 4180 IR calibrator Oven/Incubator/Freezer ELECTRICAL Source/Generate DC Current 195 C to 419 C/0.001 C 0 to µa/1 na 0 to ma/0.01 µa 0 to ma/0.1 µa 0 to ma/1 µa 0 to A/10 µa 1.1 to A/10 µa 0 to A/100 µa 11 to 20.5 A/100 µa 300 to 1000 A 0.63C 0.04% rdg 0.02% rdg 0.06% rdg 0.02% rdg 0.06% rdg 0.11% rdg 0.08% rdg 0.08% rdg 0.5% rdg Using FLUKE 9142 temperature calibrator with FLUKE 5615 PRT secondary standard Using FLUKE 5522 A multifunction calibrator direct method Using 50 Turn current coil Print Date: 1/13/2015 Page 3 of 10

4 AREA ELECTRICAL (continued) Source/Generate AC Voltage 1.0 mv to Hz to 500 Hz, /1 µv 33 V to Hz to 500 khz/1 µv 0.33 to Hz to 500 khz/10 µv 3.3 V to Hz to 100 khz/100 µv 33 V to Hz to 100 khz/1 mv 330 V to Hz to 10 khz/10 mv CAPABILITY 1 (CMC) (±) 0.137% rdg 0.104% rdg 0.08% rdg 0.08% rdg 0.08% rdg 0.063% rdg TECHNIQUE, REFERENCE STANDARD, EQUIPMENT AC Current to ma/0.01µa 0.33 to ma/0.01 µa 3.3 to ma/0.1 µa 0.09% rdg 0.110% rdg 0.266% rdg 33 to ma/1 µa 0.061% rdg 0.33 to A/10 µa 0.082% rdg 3 to 20.5 A/100 µa 0.188% rdg 300 to 1000 A /1 A 1.28% rdg Using 50 Turn current coil DC Voltage 0 to mv/0.1 µv 0.097% rdg 0 to V/1 µv 0 to V/10 µv 30 to V/100 µv 100 to V/1000 µv 0.059% rdg 0.059% rdg 0.015% rdg 0.015% rdg Using FLUKE 5522 A multifunction calibrator direct method Resistance (2 wire and 4 wire) 0 to / to / to / to / % rdg 330 to k / to k / % rdg Print Date: 1/13/2015 Page 4 of 10

5 AREA ELECTRICAL (continued) Source/Generate Resistance (2 wire and 4 wire) 3.3 to k / to k /0.01 CAPABILITY 1 (CMC) (±) 2.005% TECHNIQUE, REFERENCE STANDARD, EQUIPMENT 33 to k / to k / % rdg 330 k to M /1 1.1 to M / % Frequency 3.3 to M /10 11 to M /10 33 to M / to M / to 1100 M / % rdg 0.01 to Hz/0.01 Hz 0.01% rdg to Hz/0.1 Hz to khz/1.0 Hz to khz/10 Hz 0.011% rdg 0.289% rdg Capacitance to khz/100 Hz to MHz/1 khz 0.116% rdg 220 to pf/0.1 pf 0.4 to nf/0.1 pf 1.1 to nf/0.1 pf 3.3 to nf/0.1 pf 0.608% rdg 11 to nf/0.1 pf 33 to nf/1 pf 110 to nf/1 pf 0.33 to µf/10 pf 1.1 to µf/10 pf 3.3 to µf/100 pf 11 to µf/100 pf 33 to µf/1 nf 110 to µf/1 nf 0.33 to mf/10 nf 3.083% rdg Print Date: 1/13/2015 Page 5 of 10

6 AREA ELECTRICAL (continued) Source/Generate Temperature Simulation Temperature indicator/ /Controller/Recorder/Test Kit/ Universal Calibrator/Calibrators 200 to 800 o C, Pt 385,100 / -200 to 630 o C, Pt 3926, 100 / CAPABILITY 1 (CMC) (±) STANDARD, EQUIPMENT -200 to 630 o C, Pt 3916, 100 / -200 to 630 o C, Pt 385, 200 / -200 to 630 o C, Pt 385,500 / -200 to 630 o C, Pt 385, to 260 o C, PtNi 385, 120 (Ni120)/ -100 to 260 o C, Cu 427, 10 [3]/ 600 to 1820 C, B Type/ 0 to 2316 C, C Type/ 250 to 1000 C, E Type/ 210 to 1200 C, J Type/ 250 to 1372 C, K Type/ 200 to 900 C, L Type/ 200 to 1300 C, N Type/ 0 to 1767 C, R Type/ 0 to 1767 C, S Type/ 0.68 C 0.42 C 5522A multifunction calibrator direct method 5522A multifunction calibrator direct method 250 to 400 C, T Type/ 200 to 600 C, U Type Print Date: 1/13/2015 Page 6 of 10

7 AREA ELECTRICAL (continued) Measure CAPABILITY 1 (CMC) (±) STANDARD, EQUIPMENT DC Voltage 100 mv/100 nv 1 V/1 µv 0.006% rdg 10 V /10 µv 100 V/100 µv 1000 V/1 mv 0.02% rdg AC 50 Hz 100 mv/100 nv 1 V/1 µv 0.111% rdg 10 V/10 µv 100 V/100 µv 1000 V/1 mv 0.33% rdg DC Current 100 µa/100 pa 1 ma/1 na 10 ma/10 na 0.347% rdg 100 ma/100 na 1 A/1 µa 0.064% rdg 0.082% rdg 3 A/10 µa 10 A/10 µa 0.183% rdg 0.183% rdg AC 50 Hz 100 µa/100 pa 1 ma/1 na 10 ma/10 na 100 ma/100 na 0.423% rdg 1 A/1 µa 3 A/10 µa 10 A/10 µa 0.163% rdg 0.285% rdg 0.285% rdg Print Date: 1/13/2015 Page 7 of 10

8 AREA ELECTRICAL (continued) Measure Resistance 10 /10 µ 100 /100 µ 1 k /1 m CAPABILITY 1 (CMC) (±) 0.358% rdg 0.023% rdg 0.023% rdg STANDARD, EQUIPMENT 10 k /10 m 100 k /100 m 1 M /1 10 M / % rdg 0.073% rdg 0.073% rdg 0.073% rdg 100 M / G /1k 1.369% rdg 1.369% rdg Frequency 5 Hz to 1 MHz 0.116% rdg Temperature (RTD Pt 100) 200 C to 600 C 0.26 C Capacitance TEMPERATURE---MEASURE Temperature Indicator/Controller/Recorder/Test Kit/Universal Calibrator/Calibrators 1 nf to 1 F 1 F to 100 mf 200 to 800 o C, Pt 385, to 630 o C, Pt 3926, to 630 o C, Pt 3916, % rdg -200 to 630 o C, Pt 385, to 630 C, Pt 385, to 630 C, Pt 385, to 260 C, PtNi 385, 120 (Ni120) / -100 to 260 C, Cu 427, 10 [3]/ 0.46 C Using FLUKE and 5522A multifunction calibrator Measure Mode Print Date: 1/13/2015 Page 8 of 10

9 AREA TEMPERATURE MEASURE (continued) Temperature Indicator/Controller/Recorder/Test Kit/Universal Calibrator/Calibrators 600 to 1820 C, B Type 0 to 2316 C, C Type 250 to 1000 C, E Type 210 to 1200 C, J Type 250 to 1372 C, K Type CAPABILITY 1 (CMC) (±) STANDARD, EQUIPMENT 200 to 900 C, L Type 200 to 1300 C, N Type 0 to 1767 C, R Type 0 to 1767 C, S Type 250 to 400 C, T Type 200 to 600 C, U Type -200 to 630C, Pt 385, to 630 C, Pt 385, C Using FLUKE and 5522A multifunction calibrator Measure Mode Print Date: 1/13/2015 Page 9 of 10

10 AREA Electrical (continued) Temperature Measure Temperature Indicator/Controller/Recorder/Test Kit/Universal Calibrator/Calibrators -80 to 260 C, PtNi 385, 120 (Ni120) -100 to 260 C, Cu 427, 10 [3] 600 to 1820 C, B Type 0 to 2316 C, C Type 250 to 1000 C, E Type 210 to 1200 C, J Type 250 to 1372 C, K Type 200 to 900 C, L Type 200 to 1300 C, N Type 0 to 1767 C, R Type 0 to 1767 C, S Type 250 to 400 C, T Type 200 to 600 C, U Type CAPABILITY 1 (CMC) (±) 0.46 C STANDARD, EQUIPMENT Using FLUKE and 5522A multifunction calibrator Measure Mode 1 Calibration and Measurement Capability is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or of nearly ideal measuring instruments. Calibration and Measurement Capabilities are expressed as uncertainties at approximately the 95% level of confidence, usually using a coverage factor of k=2. The measurement uncertainty of a specific calibration performed by the laboratory may be greater than the least uncertainty due to the behavior of the customer s device, to the environment (if the calibration is performed in the field), and to influences from the circumstances of the specific calibration. Print Date: 1/13/2015 Page 10 of 10

MUHAMMAD ABDULLAH AL-AZZAZ COMPANY LIMITED P.O. BOX 31172 AL-KHOBAR 31952 KINGDOM OF SAUDI ARABIA

MUHAMMAD ABDULLAH AL-AZZAZ COMPANY LIMITED P.O. BOX 31172 AL-KHOBAR 31952 KINGDOM OF SAUDI ARABIA This is to signify that MUHAMMAD ABDULLAH AL-AZZAZ COMPANY LIMITED P.O. BOX 31172 AL-KHOBAR 31952 KINGDOM OF SAUDI ARABIA Calibration Laboratory CL-151 has met the requirements of the IAS Accreditation

More information

3M CORPORATE METROLOGY SERVICES St. Paul, MN

3M CORPORATE METROLOGY SERVICES St. Paul, MN A2LA has accredited THE AMERICAN ASSOCIATION FOR LABORATORY ACCREDITATION ACCREDITED LABORATORY 3M CORPORATE METROLOGY SERVICES St. Paul, MN for technical competence in the field of Calibration This laboratory

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994. ALLTITE, INC. 1600 Murdock, Wichita, KS 67214 Bruce Demaree Phone: 800 498 6721

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994. ALLTITE, INC. 1600 Murdock, Wichita, KS 67214 Bruce Demaree Phone: 800 498 6721 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ALLTITE, INC. 1600 Murdock, Wichita, KS 67214 Bruce Demaree Phone: 800 498 6721 CALIBRATION Valid To: September 30, 2016 Certificate

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Unit 7 Contact: Mr S C Sparks Solent Industrial Estate Tel: +44 (0)1489 790296 Hedge End Fax: +44 (0)1489 790294 Southampton E-Mail: info@southcal.co.uk

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Old Bracknell Lane West Bracknell Berkshire RG12 7AH Contact: Mr M Trotter Tel: +44 (0)1344 459314 Fax: +44 (0)1344 465556 E-Mail: mtrotter@bis.fm

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. 393.00 Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc., has assessed the Laboratory of: (Hereinafter called the Organization) and

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z540-1-1994

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z540-1-1994 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z540-1-1994 TEKTRONIX, INC. 13725 SW Karl Braun Drive Beaverton, OR 97077 Andrew Mumford Phone: 503 627 2476 CALIBRATION Valid to: June 30, 2018

More information

INyMET SALVATIERRA NO. 32-5 COL SAN BARTOLO ATEPEHUACAN D.F. 07730 MEXICO

INyMET SALVATIERRA NO. 32-5 COL SAN BARTOLO ATEPEHUACAN D.F. 07730 MEXICO This is to signify that INyMET SALVATIERRA NO. 32-5 COL SAN BARTOLO ATEPEHUACAN D.F. 07730 MEXICO Calibration Laboratory CL-101 has met the requirements of the IAS Accreditation Criteria for Calibration

More information

Scope of accreditation SP Technical Research Institute, Department of Calibration and Verification, Borås - 1002

Scope of accreditation SP Technical Research Institute, Department of Calibration and Verification, Borås - 1002 2015-12-11 2014/2779 Technical Research Institute, Department of Calibration and Verification, Borås - 1002 Accredited calibration activities are conducted at the following laboratories: Box 56 SE-230

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK code Location code Customers Sites locations: 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK Calibration Centre Bolkiah Garrison BB3510 Negara Brunei Darussalam Contact: Mr Lim Tiong Thai Tel: +673-2-386475

More information

SCS Directory Accreditation number: SCS 0115

SCS Directory Accreditation number: SCS 0115 International standard: ISO/IEC 17025:2005 Swiss standard: SN EN ISO/IEC 17025:2005 METRON SA Calibration Laboratory Via Luserte Sud 7 CH-6572 Quartino Head: Angelo Capone Responsible for MS: Angelo Capone

More information

ipimms is an industry primary impedance measurement service supplied and maintained by UK s National Physical Laboratory. [4]

ipimms is an industry primary impedance measurement service supplied and maintained by UK s National Physical Laboratory. [4] Page: 1 of 25 LABORATORY LOCATION: (PERMANENT LABORATORY) AGILENT TECHNOLOGIES MICROWAVE PRODUCTS (M) SDN. BHD. BAYAN LEPAS FREE INDUSTRIAL ZONE 11900 PENANG, MALAYSIA This laboratory accredited under

More information

Eco Green Labs India Pvt. Ltd., Ground Floor, Plot No. 100, New Sidco Industrial Estate, Srinagar, Hosur, Tamil Nadu

Eco Green Labs India Pvt. Ltd., Ground Floor, Plot No. 100, New Sidco Industrial Estate, Srinagar, Hosur, Tamil Nadu Last Amended on - Page 1 of 5 I. DIMENSION $ 1. PLAIN PLUG S Upto Ø 100 mm 1.1 m Using ULM > Ø100 mm to Ø 300 mm 2.4 m 2. PLAIN RING S Upto Ø 100 mm 1.7 m Using ULM >Ø100 mm to Ø 300 mm 3.6 m 3. THREAD

More information

Wahl C50 Calibrator FEATURES

Wahl C50 Calibrator FEATURES NEW! On Site Multifunction Portable Far Superior Accuracy as Compared to Fluke! Simultaneous Measurement and Generation Quick Connect Terminals Anti-Shock Boot Quick Connect Terminals Navigator Power Supply,

More information

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one. 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter

More information

PIN CONFIGURATION FEATURES ORDERING INFORMATION ABSOLUTE MAXIMUM RATINGS. D, F, N Packages

PIN CONFIGURATION FEATURES ORDERING INFORMATION ABSOLUTE MAXIMUM RATINGS. D, F, N Packages DESCRIPTION The µa71 is a high performance operational amplifier with high open-loop gain, internal compensation, high common mode range and exceptional temperature stability. The µa71 is short-circuit-protected

More information

Accredited Laboratory

Accredited Laboratory Accredited Laboratory A2LA has accredited CORPORATE CONSULTING SERVICE & INSTRUMENTS INC. Akron, OH for technical competence in the field of Calibration This laboratory is accredited in accordance with

More information

PowerAmp Design. PowerAmp Design PAD135 COMPACT HIGH VOLATGE OP AMP

PowerAmp Design. PowerAmp Design PAD135 COMPACT HIGH VOLATGE OP AMP PowerAmp Design COMPACT HIGH VOLTAGE OP AMP Rev G KEY FEATURES LOW COST SMALL SIZE 40mm SQUARE HIGH VOLTAGE 200 VOLTS HIGH OUTPUT CURRENT 10A PEAK 40 WATT DISSIPATION CAPABILITY 200V/µS SLEW RATE APPLICATIONS

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 F. D. HURKA COMPANY 4731 Stockholm Court Charlotte, NC 28273 Paul Yanney Phone: 704 552 0008 CALIBRATION Valid To: December 31, 2016

More information

3466 Building Energy Management Training Systems

3466 Building Energy Management Training Systems 3466 Building Energy Management Training Systems LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 06/2015 Table of Contents General Description 3 Courseware 3 Topic Coverage 4 List of Available

More information

Multifunction HVAC and IAQ Meter

Multifunction HVAC and IAQ Meter testo 435 Multifunction HVAC and IAQ Meter NEW! The newest technology for temperature, humidity, air flow and more! cfm P CO 2 %RH F Lux All the right parameters for HVAC and IAQ The testo 435 is perfect

More information

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex Data Sheet 0/-8.5 EN FieldIT Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit)

More information

Loop Calibration and Maintenance

Loop Calibration and Maintenance Loop Calibration and Maintenance Application Note Introduction Process instrumentation requires periodic calibration and maintenance to ensure that it is operating correctly. This application note contains

More information

HA-5104/883. Low Noise, High Performance, Quad Operational Amplifier. Features. Description. Applications. Ordering Information. Pinout.

HA-5104/883. Low Noise, High Performance, Quad Operational Amplifier. Features. Description. Applications. Ordering Information. Pinout. HA5104/883 April 2002 Features This Circuit is Processed in Accordance to MILSTD 883 and is Fully Conformant Under the Provisions of Paragraph 1.2.1. Low Input Noise Voltage Density at 1kHz. 6nV/ Hz (Max)

More information

STLQ015. 150 ma, ultra low quiescent current linear voltage regulator. Description. Features. Application

STLQ015. 150 ma, ultra low quiescent current linear voltage regulator. Description. Features. Application 150 ma, ultra low quiescent current linear voltage regulator Description Datasheet - production data Features SOT23-5L Input voltage from 1.5 to 5.5 V Very low quiescent current: 1.0 µa (typ.) at no load

More information

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give

More information

Environment-Laboratory Ambient Conditions

Environment-Laboratory Ambient Conditions ISSUE 3.0: MADE MINOR CLARIFICATION CHANGES. FOR CLIENT LABS Purpose To assure laboratory conditions are stable during the performance of testing and data collection. Why this requirement is important?

More information

Process Tools. 2011 Selection Guide. inside for: for industrial instrumentation and electrical technicians. Loop Calibrators. Pressure Calibrators

Process Tools. 2011 Selection Guide. inside for: for industrial instrumentation and electrical technicians. Loop Calibrators. Pressure Calibrators Process Tools for industrial instrumentation and electrical technicians 2011 Selection Guide Look inside for: Loop Calibrators Pressure Calibrators Temperature Calibrators Multifunction Process Calibrators

More information

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry

More information

2002 IS Catalog. Page

2002 IS Catalog. Page 00 IS Catalog Page Introduction... 47 Transmitter (8 V entity parameter) KFD-CR-Ex1.30.00 (-wire transmitter)... 48 KFD-CR-Ex1.30.300 (- or 3-wire transmitter)... 49 KFD-CR-Ex1.30.300 90C (- or 3-wire,

More information

Electricity and Magnetism, Georgia, GEOSTM (Georgian National Agency for Standards and Metrology)

Electricity and Magnetism, Georgia, GEOSTM (Georgian National Agency for Standards and Metrology) single references 1 1.018 V Temperature (23 ± 3) C 6 µv 2 95% No 1 single references 10 10 V Temperature (23 ± 3) C 25 µv 2 95% No 2 low ranges DMM > 0.01 10 V Temperature (23 ± 3) C 2E-06U + 3E-06 to

More information

AutoRanging Digital MultiMeter

AutoRanging Digital MultiMeter Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

VALLIAMMAI ENGINEERING COLLEGE SRM NAGAR KATTANKULATHUR DEPARTMENT OF MECHANICAL ENGINEERING ME2304 ENGINEERING METROLOGY AND MEASUREMENT

VALLIAMMAI ENGINEERING COLLEGE SRM NAGAR KATTANKULATHUR DEPARTMENT OF MECHANICAL ENGINEERING ME2304 ENGINEERING METROLOGY AND MEASUREMENT VALLIAMMAI ENGINEERING COLLEGE SRM NAGAR KATTANKULATHUR DEPARTMENT OF MECHANICAL ENGINEERING ME2304 ENGINEERING METROLOGY AND MEASUREMENT QUESTION BANK UNIT I CONCEPT OF MEASUREMENT 1. What are the uses

More information

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES 4 A CAPACITY, THE VARIETY OF CONTACT ARRANEMENTS S RELAYS FEATURES 28. 1.12 12..472 1.4.49 The variety of contact arrangements 2 Form A 2 Form B, 3 Form A 1 Form B, 4 Form A Latching types available High

More information

Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL

Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL WARNING: READ AND UNDERSTAND THIS MANUAL BEFORE USING YOUR MULTIMETER. FAILURE TO UNDERSTAND AND COMPLY WITH WARNINGS AND OPERATING INSTRUCTIONS

More information

M 140i. Multifunction Calibrator. Operation Manual

M 140i. Multifunction Calibrator. Operation Manual M 140i Multifunction Calibrator Operation Manual M-140i Multifunction Calibrator MEATEST, s.r.o. 2 Operation Manual v33 MEATEST, s.r.o. M-140i Multifunction Calibrator Content Operation Manual... 1 Basic

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS LOW-PROFILE SURFACE-MOUNT RELAY RELAYS.55 5.6. FEATURES Low-profile: 6 mm.36 inch (Tape height: max. 6.5 mm.56 inch) Tape and reel package is available as standard packing style Surge withstand between

More information

AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC

AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC QUICK REFERENCE DATA DESCRIPTION VALUE Ceramic Class 1 2 Ceramic Dielectric U2J U2J Y5S, Y5U Y5S, Y5U Voltage (V AC ) 500 760

More information

INSTRUMENTATION AND CONTROL TUTORIAL 3 SIGNAL PROCESSORS AND RECEIVERS

INSTRUMENTATION AND CONTROL TUTORIAL 3 SIGNAL PROCESSORS AND RECEIVERS INSTRUMENTATION AND CONTROL TUTORIAL 3 SIGNAL PROCESSORS AND RECEIVERS This tutorial provides an overview of signal processing and conditioning for use in instrumentation and automatic control systems.

More information

Objective. To design and simulate a cascode amplifier circuit using bipolar transistors.

Objective. To design and simulate a cascode amplifier circuit using bipolar transistors. ascode Amplifier Design. Objective. o design and simulate a cascode amplifier circuit using bipolar transistors. Assignment description he cascode amplifier utilises the advantage of the common-emitter

More information

This is to signify that

This is to signify that This is to signify that CIHAZLARI SAN. TIC. LTD. STI 1348 SOK NO: 5/401 TEKNIK MALZEME ISMERKEZI YENISEHIR/IZMIR TURKEY Calibration Laboratory CL-142 has met the requirements of the IAS Accreditation Criteria

More information

4N25 Phototransistor Optocoupler General Purpose Type

4N25 Phototransistor Optocoupler General Purpose Type 4N Phototransistor Optocoupler General Purpose Type Data Sheet Lead (Pb) Free RoHS 6 fully compliant RoHS 6 fully compliant options available; -xxxe denotes a lead-free product Description The 4N is an

More information

User's Guide. True RMS Industrial Multimeter

User's Guide. True RMS Industrial Multimeter User's Guide 97650 True RMS Industrial Multimeter Ω C ã F ã 10A V µ 10A V ã ã ma A Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),

More information

Low Cost Instrumentation Amplifier AD622

Low Cost Instrumentation Amplifier AD622 Data Sheet FEATURES Easy to use Low cost solution Higher performance than two or three op amp design Unity gain with no external resistor Optional gains with one external resistor (Gain range: 2 to 000)

More information

Fluke 3000 FC Series Test Tools Technical Data

Fluke 3000 FC Series Test Tools Technical Data Fluke 3000 FC Series Test Tools Technical Data Now compatible with Fluke Connect Mobile App Start building tomorrow s test tool system today with the Fluke 3000 FC Digital Multimeter. The new Fluke Connect

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

LAUBE TECHNOLOGY DRY REED RELAYS

LAUBE TECHNOLOGY DRY REED RELAYS LAUBE TECHNOLOGY DRY REED RELAYS CONTACT FORM CURRENT PART SERIES PAGE #'S (1A) SPST-NO 1 AMP D41A...0L 147~148 (Link) (1A) SPST-NO 1 AMP D71A.1.0 149~150 (Link) (1A) SPST-NO 1 AMP F51A.100 151~152 (Link)

More information

LABORATORY 2 THE DIFFERENTIAL AMPLIFIER

LABORATORY 2 THE DIFFERENTIAL AMPLIFIER LABORATORY 2 THE DIFFERENTIAL AMPLIFIER OBJECTIVES 1. To understand how to amplify weak (small) signals in the presence of noise. 1. To understand how a differential amplifier rejects noise and common

More information

TL084 TL084A - TL084B

TL084 TL084A - TL084B A B GENERAL PURPOSE JFET QUAD OPERATIONAL AMPLIFIERS WIDE COMMONMODE (UP TO V + CC ) AND DIFFERENTIAL VOLTAGE RANGE LOW INPUT BIAS AND OFFSET CURRENT OUTPUT SHORTCIRCUIT PROTECTION HIGH INPUT IMPEDANCE

More information

nvision Reference Recorder

nvision Reference Recorder nvision Reference Recorder Your Multi-Purpose Recorder Key Features Records 1 Million Data Points Simple to Use Intuitive keypad takes seconds to learn. Live Data Graphing Robust Drop tested from 5 feet.

More information

Linear Parameter Measurement (LPM)

Linear Parameter Measurement (LPM) (LPM) Module of the R&D SYSTEM FEATURES Identifies linear transducer model Measures suspension creep LS-fitting in impedance LS-fitting in displacement (optional) Single-step measurement with laser sensor

More information

INFRARED PARTS MANUAL

INFRARED PARTS MANUAL INFRARED PARTS MANUAL PIR325 FL65 GLOLAB CORPORATION Thank you for buying our Pyroelectric Infrared components. The goal of Glolab is to produce top quality electronic kits, products and components. All

More information

Department of Aerospace Engineering Indian Institute of Science Bangalore

Department of Aerospace Engineering Indian Institute of Science Bangalore Department of Aerospace Engineering Indian Institute of Science Bangalore Brief Outline of Department The department of Aerospace Engineering is one of the oldest departments in the country encompassing

More information

Mechanical Dimensions: Height: 3U Width: 427mm (16.8 inches) Depth: 460mm (18.1 inches) Weight: 18.5kg (41lbs). 19kg (42.1lbs) with Option 250

Mechanical Dimensions: Height: 3U Width: 427mm (16.8 inches) Depth: 460mm (18.1 inches) Weight: 18.5kg (41lbs). 19kg (42.1lbs) with Option 250 General Specifications Line Power Supply Voltage (single f): 100V/120V/220V/240V selectable from rear panel Variation: ±10% Nominal Voltage Line Frequency: 48Hz to 63Hz Consumption: 450VA max. 500VA max

More information

ngenieros Ingenieros Asociados De Control S.L.

ngenieros Ingenieros Asociados De Control S.L. ngenieros sociados de ontrol 1 Company founded in 1985 to serve commercial and technical assistance in the fields of instrumentation, control and installation for all types of industries. We offer top

More information

NTE923 & NTE923D Integrated Circuit Precision Voltage Regulator

NTE923 & NTE923D Integrated Circuit Precision Voltage Regulator NTE923 & NTE923D Integrated Circuit Precision Voltage Regulator Description: The NTE923 and NTE923D are voltage regulators designed primarily for series regulator applications. By themselves, these devices

More information

1 Form A Solid State Relay

1 Form A Solid State Relay 1 Form A Solid State Relay Vishay Semiconductors DIP i1791- SMD DESCRIPTION Vishay solid state relays (SSRs) are miniature, optically coupled relays with high-voltage MOSFET outputs. The LH1518 relays

More information

1 pc Charge Injection, 100 pa Leakage CMOS 5 V/5 V/3 V 4-Channel Multiplexer ADG604

1 pc Charge Injection, 100 pa Leakage CMOS 5 V/5 V/3 V 4-Channel Multiplexer ADG604 a FEATURES 1 pc Charge Injection (Over the Full Signal Range) 2.7 V to 5.5 V ual Supply 2.7 V to 5.5 ingle Supply Automotive Temperature Range: 4 C to +125 C 1 pa Max @ 25 C Leakage Currents 85 Typ On

More information

Reed V23100-V4 Relay. AXICOM Telecom-, Signal and RF Relays. AXICOM Telecom-, Signal and RF Relays. Reed V23100-V4 Relay

Reed V23100-V4 Relay. AXICOM Telecom-, Signal and RF Relays. AXICOM Telecom-, Signal and RF Relays. Reed V23100-V4 Relay AXICOM AXICOM 108-98011 Nov. 07 Rev. C ECOC: JM10 Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, Tyco Electronics does not

More information

Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers

Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers Flow and Flow rate. Laminar and Turbulent flow Laminar flow: smooth, orderly and regular Mechanical sensors have inertia, which can integrate out small variations due to turbulence Turbulent flow: chaotic

More information

The Best Relaytion. Reed Relays. 108-98011 Rev. B EC-JM00-0009-03 ECOC: JM10 1. Aug. 04

The Best Relaytion. Reed Relays. 108-98011 Rev. B EC-JM00-0009-03 ECOC: JM10 1. Aug. 04 The Best Relaytion Reed Relays 108-98011 Rev. B EC-JM00-0009-03 ECOC: JM10 1. Aug. 04 1 and 2 pole relays non-polarized, non-latching Features Direct coil control with TTL-signals possible Highly reliable

More information

INTEGRATED CIRCUITS DATA SHEET. TDA7000 FM radio circuit. Product specification File under Integrated Circuits, IC01

INTEGRATED CIRCUITS DATA SHEET. TDA7000 FM radio circuit. Product specification File under Integrated Circuits, IC01 INTEGRATED CIRCUITS DATA SHEET File under Integrated Circuits, IC01 May 1992 GENERAL DESCRIPTION The is a monolithic integrated circuit for mono FM portable radios, where a minimum on peripheral components

More information

Features. Ordering Information. * Underbar marking may not be to scale. Part Identification

Features. Ordering Information. * Underbar marking may not be to scale. Part Identification MIC86 Teeny Ultra Low Power Op Amp General Description The MIC86 is a rail-to-rail output, input common-mode to ground, operational amplifier in Teeny SC7 packaging. The MIC86 provides 4kHz gain-bandwidth

More information

Precision, Unity-Gain Differential Amplifier AMP03

Precision, Unity-Gain Differential Amplifier AMP03 a FEATURES High CMRR: db Typ Low Nonlinearity:.% Max Low Distortion:.% Typ Wide Bandwidth: MHz Typ Fast Slew Rate: 9.5 V/ s Typ Fast Settling (.%): s Typ Low Cost APPLICATIONS Summing Amplifiers Instrumentation

More information

R=Required by Lab S=May be subcontracted IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES

R=Required by Lab S=May be subcontracted IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES IEC SYSTEM FO CONFOMITY TESTING AND CETIFICATION OF ELECTICAL EQUIPMENT COMMITTEE OF TESTING LABOATOIES TESTING AND MEASUING EQUIPMENT/ALLOWED SUBCONTACTING Power cables with extruded insulation and their

More information

SG2525A SG3525A REGULATING PULSE WIDTH MODULATORS

SG2525A SG3525A REGULATING PULSE WIDTH MODULATORS SG2525A SG3525A REGULATING PULSE WIDTH MODULATORS 8 TO 35 V OPERATION 5.1 V REFERENCE TRIMMED TO ± 1 % 100 Hz TO 500 KHz OSCILLATOR RANGE SEPARATE OSCILLATOR SYNC TERMINAL ADJUSTABLE DEADTIME CONTROL INTERNAL

More information

Silicon NPN Phototransistor

Silicon NPN Phototransistor Silicon NPN Phototransistor DESCRIPTION 7 is a silicon NPN phototransistor with high radiant sensitivity in black, T-1¾ plastic package with base terminal and daylight blocking filter. Filter bandwidth

More information

Multifunction Process Calibrator

Multifunction Process Calibrator 725 Multifunction Process Calibrator Product Overview PN 1549644 English January 2000 Rev.2, 8/05 2000-2005 Fluke Corporation. All rights reserved. Printed in USA All product names are trademarks of their

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

2000 6½-Digit Multimeter

2000 6½-Digit Multimeter 13 built-in measurement functions 2000 readings/second at 4½ digits Optional scanner cards for multipoint measurements IEEE-488 and RS-232 interfaces Fluke 8840/42 command set Ordering Information 2000

More information

Optocoupler, Phototransistor Output, with Base Connection

Optocoupler, Phototransistor Output, with Base Connection 4N25, 4N26, 4N27, 4N28 Optocoupler, Phototransistor Output, FEATURES A 6 B Isolation test voltage 5000 V RMS Interfaces with common logic families C 2 5 C Input-output coupling capacitance < pf NC 3 4

More information

DS 600. A contact free flux gate based current measurement sensor 600A rms

DS 600. A contact free flux gate based current measurement sensor 600A rms DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum

More information

IR Receiver Module for Light Barrier Systems

IR Receiver Module for Light Barrier Systems Not for New Design - Alternative Available: New TSSP4038 (#82458) www.vishay.com IR Receiver Module for Light Barrier Systems TSOP4038 2 3 MECHANICAL DATA Pinning: = OUT, 2 = GND., 3 = V S 6672 FEATURES

More information

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic

More information

High Common-Mode Rejection. Differential Line Receiver SSM2141. Fax: 781/461-3113 FUNCTIONAL BLOCK DIAGRAM FEATURES. High Common-Mode Rejection

High Common-Mode Rejection. Differential Line Receiver SSM2141. Fax: 781/461-3113 FUNCTIONAL BLOCK DIAGRAM FEATURES. High Common-Mode Rejection a FEATURES High Common-Mode Rejection DC: 00 db typ 60 Hz: 00 db typ 20 khz: 70 db typ 40 khz: 62 db typ Low Distortion: 0.00% typ Fast Slew Rate: 9.5 V/ s typ Wide Bandwidth: 3 MHz typ Low Cost Complements

More information

Torque Transducers MEASURING ELECTRONIC

Torque Transducers MEASURING ELECTRONIC Screwdriving technology Automation Air motors Air tools MEASURING ELECTRONIC Torque Transducers In most situations, the essential element of screwdriving technology is torque. Controlling the torque generated

More information

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules CHIEF EN TERPRISES INC. M a s t e r I n t e r n a t i o n a l D i s t r i b u t o r Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules M AS TER IN

More information

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently (68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please

More information

Thermal Flow Sensor Die

Thermal Flow Sensor Die Microsystems, Inc. Thermal Flow Sensor Die Description Posifa s Thermal Flow Sensor Die measures the flow of a liquid or gaseous medium across the surface of the die using the Thermotransfer (Calorimetric)

More information

Op Amp Circuit Collection

Op Amp Circuit Collection Op Amp Circuit Collection Note: National Semiconductor recommends replacing 2N2920 and 2N3728 matched pairs with LM394 in all application circuits. Section 1 Basic Circuits Inverting Amplifier Difference

More information

HIGH VOLTAGE LABORATORY INSTYTUT ENERGETYKI

HIGH VOLTAGE LABORATORY INSTYTUT ENERGETYKI HIGH VOLTAGE LABORATORY INSTYTUT ENERGETYKI POLAND 01-330 WARSZAWA, ul. Mory 8, tel. (+48 22) 836-80-48, fax (+48 22) 836-80-48 e-mail: ewn@ien.com.pl EWN/70/E/11-1 APPENDIX 4 APPENDIX 4 for test report

More information

FP2 Relay. The Best Relaytion

FP2 Relay. The Best Relaytion The Best Relaytion 2 pole telecom / signal relay Through Hole Type (THT) Polarized. Relay types: non-latching with1 coil latching with 1 coil latching with 2 coils Features Telecom / signal relay (dry

More information

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar. CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension

More information

Application Note. So You Need to Measure Some Inductors?

Application Note. So You Need to Measure Some Inductors? So You Need to Measure Some nductors? Take a look at the 1910 nductance Analyzer. Although specifically designed for production testing of inductors and coils, in addition to measuring inductance (L),

More information

Mobile Communications DC Sources 40-100 W

Mobile Communications DC Sources 40-100 W 40-100 W 66319B/D, 66321B/D Ideal for testing wireless and battery powered devices Several times improvement in measurement throughput over general purpose DC sources Superior output transient performance

More information

I-PEX MHF4 Micro Coaxial Connector

I-PEX MHF4 Micro Coaxial Connector PRODUCT SPECIFICATION I-PEX MHF4 Micro Coaxial Connector Plug P/N 20448-001R-81 Receptacle P/N 20449-001E RF Connector, RF Cable & Antenna Manufacturer E-mail: sales@wellshow.com.tw Tel: +886-2-24239376

More information

INDUSTRIAL VOLTAGE AMPLIFIER IC AM401 PRINCIPLE FUNCTION

INDUSTRIAL VOLTAGE AMPLIFIER IC AM401 PRINCIPLE FUNCTION PINCIPLE FUNCTION Amplification and conversion of differential signals referenced to ground to adjustable industrial voltages (0...Vcc-5V, e.g. 0...5/10V etc.) Variable current/voltage source and integrated

More information

CLASS TEST GRADE 11. PHYSICAL SCIENCES: PHYSICS Test 3: Electricity and magnetism

CLASS TEST GRADE 11. PHYSICAL SCIENCES: PHYSICS Test 3: Electricity and magnetism CLASS TEST GRADE 11 PHYSICAL SCIENCES: PHYSICS Test 3: Electricity and magnetism MARKS: 45 TIME: 1 hour INSTRUCTIONS AND INFORMATION 1. Answer ALL the questions. 2. You may use non-programmable calculators.

More information

Four quadrant diode front end module for the Virgo Linear Alignment 3/ 30 mw, plus configuration

Four quadrant diode front end module for the Virgo Linear Alignment 3/ 30 mw, plus configuration NI K HEF NATIONAL INSTITUTE FOR NUCLEAR AND HIGH ENERGY PHYSICS Four quadrant diode front end module for the Virgo Linear Alignment 3/ 30 mw, plus configuration Find the most recent files and related files

More information

Supertex inc. HV256. 32-Channel High Voltage Amplifier Array HV256. Features. General Description. Applications. Typical Application Circuit

Supertex inc. HV256. 32-Channel High Voltage Amplifier Array HV256. Features. General Description. Applications. Typical Application Circuit 32-Channel High Voltage Amplifier Array Features 32 independent high voltage amplifiers 3V operating voltage 295V output voltage 2.2V/µs typical output slew rate Adjustable output current source limit

More information

Applying LDV to Air and Water Flow Measurements: Research Activities & Accreditation. Matthew A. Rasmussen, Danish Technological Institute

Applying LDV to Air and Water Flow Measurements: Research Activities & Accreditation. Matthew A. Rasmussen, Danish Technological Institute Applying LDV to Air and Water Flow Measurements: Research Activities & Accreditation Matthew A. Rasmussen, Danish Technological Institute Euramet Flow Meeting Danish Technological Institute, Taastrup 10-12

More information

Highly efficient flue gas analyzer

Highly efficient flue gas analyzer Highly efficient flue gas analyzer testo 320 Just a few clicks away from a heating system diagnosis O 2 High-resolution colour graphic display Quick and easy menu structure Storage space for 500 measurement

More information

Chapter 15: Transformer design

Chapter 15: Transformer design Chapter 15 Transformer Design Some more advanced design issues, not considered in previous chapter: : n Inclusion of core loss + + Selection of operating flux i 1 density to optimize total loss v 1 v Multiple

More information

MOSFET N-channel enhancement switching transistor IMPORTANT NOTICE. http://www.philips.semiconductors.com use http://www.nxp.com

MOSFET N-channel enhancement switching transistor IMPORTANT NOTICE. http://www.philips.semiconductors.com use http://www.nxp.com Rev. 3 21 November 27 Product data sheet Dear customer, IMPORTANT NOTICE As from October 1st, 26 Philips Semiconductors has a new trade name - NXP Semiconductors, which will be used in future data sheets

More information

(Issued 1 Dec. 1965) CRD-C 45-65 METHOD OF TEST FOR THERMAL CONDUCTIVITY OF LIGHTWEIGHT INSULATING CONCRETE 1

(Issued 1 Dec. 1965) CRD-C 45-65 METHOD OF TEST FOR THERMAL CONDUCTIVITY OF LIGHTWEIGHT INSULATING CONCRETE 1 CRD-C 45-65 METHOD OF TEST FOR THERMAL CONDUCTIVITY OF LIGHTWEIGHT INSULATING CONCRETE 1 Scope 1. This method of test covers a procedure for measuring the thermal conductivity of lightweight concrete of

More information

Process Calibration Tools

Process Calibration Tools Process Calibration Tools A full range of accurate, rugged and reliable calibration solutions for field and bench applications Electrical, Multifunction, and ma Loop Calibration Pressure and Flow Calibration

More information

New thermometers and accessories to grow your business

New thermometers and accessories to grow your business New s and accessories to grow your business Fluke is introducing a new family of digital, contact s and accessories. Here is the information you will need to order, promote and sell these exciting, new

More information

AC and Pulse Film Foil Capacitors KP Radial Potted Type

AC and Pulse Film Foil Capacitors KP Radial Potted Type AC and Pulse Film Foil Capacitors KP Radial Potted Type 0.5 L max. W max. Marking H max. FEATURES 5 mm lead pitch, supplied loose in box taped in ammopack or reel Material categorization: for definitions

More information