MUHAMMAD ABDULLAH AL-AZZAZ COMPANY LIMITED P.O. BOX AL-KHOBAR KINGDOM OF SAUDI ARABIA

Size: px
Start display at page:

Download "MUHAMMAD ABDULLAH AL-AZZAZ COMPANY LIMITED P.O. BOX 31172 AL-KHOBAR 31952 KINGDOM OF SAUDI ARABIA"

Transcription

1 This is to signify that MUHAMMAD ABDULLAH AL-AZZAZ COMPANY LIMITED P.O. BOX AL-KHOBAR KINGDOM OF SAUDI ARABIA Calibration Laboratory CL-151 has met the requirements of the IAS Accreditation Criteria for Calibration Laboratories (AC204), has demonstrated compliance with the ISO/IEC Standard 17025:2005, General requirements for the competence of testing and calibration laboratories, and has been accredited commencing, for the calibration discipline(s) listed in the approved scope of accreditation. The laboratory meets IAS program requirements in the field of calibration. Patrick V. McCullen Vice, Chief Technical Officer (see attached scope of accreditation for fields of calibration and accredited calibration methods) Print Date: 11/18/2014 Page 1 of 8

2 Muhammad Abdullah Al-Azzaz Company Limited Muhammad Jawad Ali P.O. Box Technical Manager Al-Khobar / Ext: 222 Kingdom of Saudi Arabia AREA Dimensional Calipers Dial and Vernier Digital RANGE & RESOLUTION 0 to 300mm/0.02mm 0 to 300mm/0.01mm CAPABILITY 1 (CMC) 15µm 11µm BS/EN/ISO , gage blocks BS/EN/ISO , gage blocks Plunger Type Indicators Dial Digital 0 to 25mm/0.01mm 0 to 25mm/0.001mm 6µm 2µm BS 907, Dial Gage Calibrator Outside Micrometers Plain Anvil Digital 0 to 25mm/0.01mm >25 to 150mm/0.01mm 0 to 25mm/0.001mm >25 to 150mm/0.001mm 6µm 7µm 0.8µm 3µm BS/EN.ISO 3611, Gage blocks Coating Thickness Guage Mechanical Force Compression 0 to 1600 micron/1 micron 0 to 1600 micron/0.1micron 0 to 3000kN/0.01kN 0.8 micron 0.5 micron 0.11% Reading ISO/IEC WD 2178 BS/EN/ISO 7500, Load Cells Balances 0 to 210g >201g to 2.1kg >2.1 to 8kg >8 to 30kg See NOTE SASO 524, Class F1 Weights Pressure Gages 0 to 10 bar/0.1 bar 0 to 60 bar/0.5 bar 0 to 100 bar/1 bar 0 to 600 bar/2 bar 0.06 bar Reading 0.3 bar Reading 0.6 bar Reading 1.3 bar Reading BS/EN 837-1, Dead Weight Tester Vacuum Gages 0 to 30 in Hg/1 in Hg (0 to 30in Hg/0.2in Hg) 0.6 in Hg Reading 0.12in Hg Reading BS/EN 837-1, Test pump and master gage Safety Relief Valve 0 to 860 psi 6.1 psi API 526 and API 527, Test Pump and Standard Pressure gages Print Date: 11/18/2014 Page 2 of 8

3 AREA RANGE & RESOLUTION Ovens Thermal 0 to 250 C 0.6 C ASTM E 145, RTD, Temperature Calibrator Thermometers Dial Digital -10 C to 200 C/5 C -10 C to 200 C/0.1 C 2.9 C 0.21 C ASME B , RTD, Dry Block, Oil Bath ASTM E 2877, RTD, Dry Block, oil Bath RTD -10 C to 200 C 0.2 C ASTM E 1137, Universal Calibrator, Dry block, oil Bath, Comparison to Standard RTD Water Baths 0 C to 90 C 0.2 C ASTM E 77 and ASTM E 715, RTD, Temperature Calibrator Furnaces Electrical Welding Machines 0 C to 1100 C 0 to 600A 0 to 50VDC 1.6 C 1.2% of Setting 0.1VDC ASTM E 145, Type S Thermocouple, Temperature Calibrator BS/EN 50504, BS 7570, ESAB Check Master 9000 Holiday Detector Electromagnetic DC voltage Generate 0 to 999VDC >999V to99.9kvdc (0 to ) mv (0.33 to ) V (3.3 to ) V (33 to ) V (330 to ) V 0.12kVDC 0.12kVDC mv mv +0.4 mv V V ASTM D 5162, Mini DC Crest Meter DC Voltage Measure mv 100 mv-1 V 1V-10 V 10V-100 V 100V-1000 V mv mv mv V V mv 100 mv-1 V 1V-10 V 10V-100 V 100V-1000 V mv mv mv V V Print Date: 11/18/2014 Page 3 of 8

4 AREA RANGE & RESOLUTION Electromagnetic (continued) DC Current Generate (0 to ) μa (0 to ) ma (0 to ) ma (0 to ) ma (0 to ) A (1.1 to ) A (0 to ) A (11 to 20.5) A ua ua ma ma ma ma +1.4 ma A DC Current Measure μa 100uA-1 ma 1mA-10 ma 10-mA-100 ma 100mA-400 ma 400mA-1 A 1A-3 A 3A-10 A ua ua ua +3.3 ua ma ma +1.1 ma +1.2 ma Resistance Generate 0-1 kω 1 kω -10 kω 10 kω -100 kω 100 kω -1 MΩ 1 MΩ -10 MΩ 10 MΩ -100 MΩ 100 MΩ -1 GΩ Ω Ω +1.2 Ω kω kω MΩ +1.1 MΩ Decade Resistance Box Resistance Measure Ω 100 Ω -1 kω 1 kω -10 kω 10 kω -100 kω 100 kω -1 MΩ 1 MΩ -10 MΩ 10 MΩ -100 MΩ 100 MΩ -1 GΩ +2.3 m Ω Ω Ω +1.53Ω kω kω MΩ MΩ AC Voltage Generate (1 to ) mv (33 to ) mv (0.33 to ) V (3.3 to ) V (33 to ) V (330 to 1020) V Frequency 10 Hz to 500 khz 10 Hz to 500 khz 10 Hz to 500 khz 10 Hz to 100 khz 45 Hz to 100 khz 45 Hz to 10 khz mv mv mv +4.5 mv V V Print Date: 11/18/2014 Page 4 of 8

5 AREA RANGE & RESOLUTION Electromagnetic (continued) AC Voltage Measure mv 100mV-1 V 1V-10 V 10V-100 V 100V-1000 V 3 Hz to 300 khz 10 Hz to 300 khz 10 Hz to 300 khz 10 Hz to 300 khz 10 Hz to 300 khz mv mv +2.8 mv V V AC Current Generate (29.00 to ) μa (0.33 to ) ma (3.3 to ) ma (33 to ) ma (0.33 to ) A (1.1 to ) A (11 to 20.5) A 10 Hz to 30 khz 10 Hz to 30 khz 10 Hz to 30 khz 10 Hz to 30 khz 10 Hz to 10 khz 10 Hz to 10 khz 45 Hz to 5 khz ua ua ma ma ma A A AC Current Measure μa 1uA-1 ma 1mA-10 ma 10mA-100 ma 100mA-400 ma 400mA-1 A 1A-3 A 3A-10 A Electrical Calibration of Thermocouples Generate and Measure Type B (600 to 1820) ºC ua ua +3.1 ua +3.2 ua ma ma +4.5 ma +4.5 ma Generate: ºC Measure: ºC Type C (0 to 2316) ºC Type E (-250 to 1000) ºC Generate: ºC Type J (-210 to 1200) ºC Type K (-200 to 1372) ºC Print Date: 11/18/2014 Page 5 of 8

6 AREA RANGE & RESOLUTION Electrical Calibration of Thermocouples Generate and Measure (continued) Type N (-200 to 1300) ºC Type R (0 to 1767) ºC Type S (0 to 1767) ºC Type T (-250 to 400) ºC Generate: ºC Type U (-200 to 600) ºC Generate: ºC Type L Electrical Calibration of RTD Generate (-200 to 900) ºC Generate: ºC Pt 385, 100 Ω (-200 to 800) ºC ºC Pt 385, 200 Ω (-200 to 630) ºC ºC Temperature Calibrator Fluke 525B Pt 385, 500 Ω (-200 to 630) ºC ºC Pt 385, 1000 Ω (-200 to 630) ºC ºC Print Date: 11/18/2014 Page 6 of 8

7 AREA RANGE & RESOLUTION Capacitance - Generate Capacitance Measure Nuclear Density Gauges Torque Wrench (220.0 to 399.9) pf (0.4 to ) nf (1.1 to ) nf (3.3 to ) nf (11 to ) nf (110 to ) nf (0.33 μf to μf (1.1 to ) μf (3.3 to ) μf (11 to ) μf (33 to ) μf (110 to ) μf (0.33 to ) mf (1.1 to ) mf (3.3 to ) mf (11 to ) mf (33 to ) mf 0-1 nf 1nF-10 nf 10nF-100 nf 100nF-1 μf 1uF-10 μf 10uF-100 μf 100uF-1 mf 1mF-10 mf 10mF-100 mf +3.8 pf nf nf nf nf nf nf uf uf uf uf +0.6 uf +0.7 uf mf mf mf mf nf nf nf +6.3 nf uf uf +6.9 uf mf mf Density: 1120 to 2723 kg/m Kg/m 3 ASTM D 6938 Nuclear Validator Note: Models that will be calibrated: VPN Troxler (3411, 3430, 3440, 3440+) Humboldt 0-50 N-m N-m N-m N-m N-m N-m N-m N-m N-m +6.2 N-m ISO 6789 Torque Wrench Calibrator & Transducers Sound Level Meter db db ANSI S1.4 Acoustic Calibrator Vibration Meter Up to 20 m/s m/s2 ISO 2954 Vibration Calibrator Print Date: 11/18/2014 Page 7 of 8

8 AREA RANGE & RESOLUTION Multi Gas Detector Methane 50% LEL, O2: 20.9%, H2S: 25 ppm, Co: 100 ppm Hardness Testing Machines HRA HRB HRC HR15N HR30N HR45N HB3000 HB500 +2% ±0.82 HRA ±0.83 HRB ±0.84 HRC ±0.78 HR ±0.82 HR ±0.77 HR ±4.2 HB ±1.45 HB ASTM E-18 ASTM E-10 BS EN Standard Span Calibration Gases Standard Test Blocks 1 Calibration and Measurement Capability is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or of nearly ideal measuring instruments. Calibration and Measurement Capabilities are expressed as uncertainties at approximately the 95% level of confidence, usually using a coverage factor of k=2. The measurement uncertainty of a specific calibration performed by the laboratory may be greater than the least uncertainty due to the behavior of the customer s device, to the environment (if the calibration is performed in the field), and to influences from the circumstances of the specific calibration. NOTE: Calibration parameters are performed primarily on-site at customer locations. The uncertainty of scale/balance calibration is highly dependent on local conditions, such as scale resolution and sensitivity, scale cleanliness, local gravity, temperature and humidity, dust, vibration, etc.; therefore, any statement of uncertainty is misleading. The class of the best weights used by the laboratory is shown in the Technique column. Use of weights in combination, whether in the same class or different classes, will increase measurement uncertainty resulting from the additive effect of weight tolerances, as defined in ASTM E 617. Print Date: 11/18/2014 Page 8 of 8

PROMPT ENGINEERING & TRADING SERVICES CO. W.L.L P.O. BOX 24067 BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR

PROMPT ENGINEERING & TRADING SERVICES CO. W.L.L P.O. BOX 24067 BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR This is to signify that PROMPT ENGINEERING & TRADING SERVICES CO. W.L.L P.O. BOX 24067 BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR Calibration Laboratory CL-165 has met the requirements

More information

3M CORPORATE METROLOGY SERVICES St. Paul, MN

3M CORPORATE METROLOGY SERVICES St. Paul, MN A2LA has accredited THE AMERICAN ASSOCIATION FOR LABORATORY ACCREDITATION ACCREDITED LABORATORY 3M CORPORATE METROLOGY SERVICES St. Paul, MN for technical competence in the field of Calibration This laboratory

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994. ALLTITE, INC. 1600 Murdock, Wichita, KS 67214 Bruce Demaree Phone: 800 498 6721

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994. ALLTITE, INC. 1600 Murdock, Wichita, KS 67214 Bruce Demaree Phone: 800 498 6721 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ALLTITE, INC. 1600 Murdock, Wichita, KS 67214 Bruce Demaree Phone: 800 498 6721 CALIBRATION Valid To: September 30, 2016 Certificate

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK code Location code Customers Sites locations: 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK Calibration Centre Bolkiah Garrison BB3510 Negara Brunei Darussalam Contact: Mr Lim Tiong Thai Tel: +673-2-386475

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. 393.00 Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc., has assessed the Laboratory of: (Hereinafter called the Organization) and

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Unit 7 Contact: Mr S C Sparks Solent Industrial Estate Tel: +44 (0)1489 790296 Hedge End Fax: +44 (0)1489 790294 Southampton E-Mail: info@southcal.co.uk

More information

INyMET SALVATIERRA NO. 32-5 COL SAN BARTOLO ATEPEHUACAN D.F. 07730 MEXICO

INyMET SALVATIERRA NO. 32-5 COL SAN BARTOLO ATEPEHUACAN D.F. 07730 MEXICO This is to signify that INyMET SALVATIERRA NO. 32-5 COL SAN BARTOLO ATEPEHUACAN D.F. 07730 MEXICO Calibration Laboratory CL-101 has met the requirements of the IAS Accreditation Criteria for Calibration

More information

SCS Directory Accreditation number: SCS 0115

SCS Directory Accreditation number: SCS 0115 International standard: ISO/IEC 17025:2005 Swiss standard: SN EN ISO/IEC 17025:2005 METRON SA Calibration Laboratory Via Luserte Sud 7 CH-6572 Quartino Head: Angelo Capone Responsible for MS: Angelo Capone

More information

Scope of accreditation SP Technical Research Institute, Department of Calibration and Verification, Borås - 1002

Scope of accreditation SP Technical Research Institute, Department of Calibration and Verification, Borås - 1002 2015-12-11 2014/2779 Technical Research Institute, Department of Calibration and Verification, Borås - 1002 Accredited calibration activities are conducted at the following laboratories: Box 56 SE-230

More information

Eco Green Labs India Pvt. Ltd., Ground Floor, Plot No. 100, New Sidco Industrial Estate, Srinagar, Hosur, Tamil Nadu

Eco Green Labs India Pvt. Ltd., Ground Floor, Plot No. 100, New Sidco Industrial Estate, Srinagar, Hosur, Tamil Nadu Last Amended on - Page 1 of 5 I. DIMENSION $ 1. PLAIN PLUG S Upto Ø 100 mm 1.1 m Using ULM > Ø100 mm to Ø 300 mm 2.4 m 2. PLAIN RING S Upto Ø 100 mm 1.7 m Using ULM >Ø100 mm to Ø 300 mm 3.6 m 3. THREAD

More information

Accredited Laboratory

Accredited Laboratory Accredited Laboratory A2LA has accredited CORPORATE CONSULTING SERVICE & INSTRUMENTS INC. Akron, OH for technical competence in the field of Calibration This laboratory is accredited in accordance with

More information

Fluke 3000 FC Series Test Tools Technical Data

Fluke 3000 FC Series Test Tools Technical Data Fluke 3000 FC Series Test Tools Technical Data Now compatible with Fluke Connect Mobile App Start building tomorrow s test tool system today with the Fluke 3000 FC Digital Multimeter. The new Fluke Connect

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z540-1-1994

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z540-1-1994 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z540-1-1994 TEKTRONIX, INC. 13725 SW Karl Braun Drive Beaverton, OR 97077 Andrew Mumford Phone: 503 627 2476 CALIBRATION Valid to: June 30, 2018

More information

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Panel Meters and Controllers Modular Panel Meter Type EDM 35 Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming

More information

Calibration. How can you get lower costs for the calibration? What is traceability? What is measurement uncertainty? What is calibration?

Calibration. How can you get lower costs for the calibration? What is traceability? What is measurement uncertainty? What is calibration? Calibration Tvinnargatan 25 SE-507 30 Brämhult SWEDEN Phone: +46 33 22 56 30 Fax: +46 33 13 88 71 info@kalibrera.se www.kalibrera.se In May 2011 Elastocon purchased the company Mätcentrum in Eskilstuna,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 F. D. HURKA COMPANY 4731 Stockholm Court Charlotte, NC 28273 Paul Yanney Phone: 704 552 0008 CALIBRATION Valid To: December 31, 2016

More information

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one. 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Old Bracknell Lane West Bracknell Berkshire RG12 7AH Contact: Mr M Trotter Tel: +44 (0)1344 459314 Fax: +44 (0)1344 465556 E-Mail: mtrotter@bis.fm

More information

Calibration Certificate

Calibration Certificate P.O. Box 87-0087 Phone:856-686-1600 Fax:856-686-1601 www.troemner.com e-mail: troemner@troemner.com SECTION 1: Page 1 of 7 Pages SECTION 2: APPROVED SIGNATORY Joseph Moran SECTION 3: PERSON PERFORMING

More information

No.1. Digital Multimeter RIGOL TECHNOLOGIES, INC.

No.1. Digital Multimeter RIGOL TECHNOLOGIES, INC. No.1 DM368 6½ digits Digital Multimeter Real 6 ½ digits readings resolution Up to 1 K rdgs/s of measurement speed and 512 K rdgs Nonvolatile Memory TrueRMS AC Voltage Current measuring Builtin 1 groups

More information

Technical Specification. Generating Set with Waukesha engine burning natural gas

Technical Specification. Generating Set with Waukesha engine burning natural gas Technical Specification Generating Set with Waukesha engine burning natural gas The following presents the Gas Engine Generating Set (GEGS) APG1000 type, based on Waukesha gas engine 16V150LTD. Using the

More information

5320A Multifunction Electrical Tester Calibrator. Verify and calibrate electrical test tools with a single instrument

5320A Multifunction Electrical Tester Calibrator. Verify and calibrate electrical test tools with a single instrument 5320A Multifunction Electrical Tester Calibrator Verify and calibrate electrical test tools with a single instrument 2 5320A Multifunction Electrical Tester Calibrator: Wide workload coverage with a single

More information

ipimms is an industry primary impedance measurement service supplied and maintained by UK s National Physical Laboratory. [4]

ipimms is an industry primary impedance measurement service supplied and maintained by UK s National Physical Laboratory. [4] Page: 1 of 25 LABORATORY LOCATION: (PERMANENT LABORATORY) AGILENT TECHNOLOGIES MICROWAVE PRODUCTS (M) SDN. BHD. BAYAN LEPAS FREE INDUSTRIAL ZONE 11900 PENANG, MALAYSIA This laboratory accredited under

More information

ngenieros Ingenieros Asociados De Control S.L.

ngenieros Ingenieros Asociados De Control S.L. ngenieros sociados de ontrol 1 Company founded in 1985 to serve commercial and technical assistance in the fields of instrumentation, control and installation for all types of industries. We offer top

More information

Process Tools. 2011 Selection Guide. inside for: for industrial instrumentation and electrical technicians. Loop Calibrators. Pressure Calibrators

Process Tools. 2011 Selection Guide. inside for: for industrial instrumentation and electrical technicians. Loop Calibrators. Pressure Calibrators Process Tools for industrial instrumentation and electrical technicians 2011 Selection Guide Look inside for: Loop Calibrators Pressure Calibrators Temperature Calibrators Multifunction Process Calibrators

More information

Unmatched Metal Hardness Testing

Unmatched Metal Hardness Testing Unmatched Metal Hardness Testing The Equostat 3 hardness tester can be connected both to the portable Equotip 3 platform and directly to a PC, with graphic user guidance Hardness Measurements made easy

More information

Loop Calibration and Maintenance

Loop Calibration and Maintenance Loop Calibration and Maintenance Application Note Introduction Process instrumentation requires periodic calibration and maintenance to ensure that it is operating correctly. This application note contains

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 MGA RESEARCH CORPORATION 820 Suburban Park Drive Greer, SC 29651 Jennifer Young Phone: (864) 848-3088 Website: www.mgaresearch.com MECHANICAL Valid Until: May

More information

Environment-Laboratory Ambient Conditions

Environment-Laboratory Ambient Conditions ISSUE 3.0: MADE MINOR CLARIFICATION CHANGES. FOR CLIENT LABS Purpose To assure laboratory conditions are stable during the performance of testing and data collection. Why this requirement is important?

More information

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features P3000 Series Pneumatic Deadweight Testers P3000 Technical Data Features Pressure ranges from Vacuum through 2 000 psi (140 bar) Accuracy better than 0.015 % of reading. (Increased accuracy option of 0.008

More information

Fluke 3000 FC Series Test Tools Technical Data

Fluke 3000 FC Series Test Tools Technical Data Fluke 3000 FC Series Test Tools Technical Data Now compatible with Fluke Connect Mobile App Start building tomorrow s test tool system today with the Fluke 3000 FC Digital Multimeter. The new Fluke Connect

More information

Agilent U1230 Series Handheld Digital Multimeters (DMMs)

Agilent U1230 Series Handheld Digital Multimeters (DMMs) Agilent U1230 Series Handheld Digital Multimeters (DMMs) Data Sheet Retool your expectations with the new Agilent U1230 Series Handheld DMMsthe first to combine a built-in LED flashlight, both audible

More information

Agilent 4338B Milliohm Meter

Agilent 4338B Milliohm Meter Agilent 4338B Milliohm Meter 10 µω to 100 kω Technical Overview Introduction Ideal for precise measurements of extremely low resistances using an ac test signal, the Agilent Technologies 4338B suits bench-top

More information

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands: Oil & Gas / Heavy Industry EX-Proof Stainless Steel Shaft Encoder - Ø 68 mm Shaft - Ø 10 mm to Ø 5/8 inch Resolution up to 10,000 ppr IP 66 (IP 67 option) ATEX certified EX-Proof IECEx certified EX-Proof

More information

On-line Dissolved Gas Analysis

On-line Dissolved Gas Analysis On-line Dissolved Gas Analysis accord. to IEC 567/ASTM 3612 Online-Monitoring of transformers Automatic on-line analysis of 11 gases The analysis is done in 2 steps with high selectivity and accuracy fully

More information

Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l

Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l D C S e r v o S y s t e m s RH Mini Series Total Motion Control Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l Precision Gearing & Motion Control DC SERVO ACTUATORS

More information

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject

More information

Micro Motion 3098 Gas Specific Gravity Meter

Micro Motion 3098 Gas Specific Gravity Meter Product Data Sheet PS-001161, Rev. D April 2013 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.

More information

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =

More information

Current Sensor: ACS755xCB-050

Current Sensor: ACS755xCB-050 Package CB-PFF 5 4 The Allegro ACS75x family of current sensors provides economical and precise solutions for current sensing in industrial, automotive, commercial, and communications systems. The device

More information

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment

More information

Pressure calibration equipment

Pressure calibration equipment Pressure calibration equipment Pressure calibration evolution 1925 Westertoren in Amsterdam 30 meter mercury column (±40 bar) 1950 comparison test pump 21 st century Stiko gas driven differential deadweight

More information

Torque Transducers MEASURING ELECTRONIC

Torque Transducers MEASURING ELECTRONIC Screwdriving technology Automation Air motors Air tools MEASURING ELECTRONIC Torque Transducers In most situations, the essential element of screwdriving technology is torque. Controlling the torque generated

More information

Fire & Security DETECTORS

Fire & Security DETECTORS Fire & Security DETECTORS Smoke Sensitivity 0.98 ~.0%/ft Obscuration Ceiling Spacing 50 foot rating for heat sensor Temperature Range 10ºC to 50ºC Humidity 0 to 95% RH, no condensation or icing Dimensions

More information

Enclosures 1-866-338-0988. DuraSystems Barriers, Inc. www.durasystems.com Email: sales@durasystems.com. The Passive Fire Protection Specialists

Enclosures 1-866-338-0988. DuraSystems Barriers, Inc. www.durasystems.com Email: sales@durasystems.com. The Passive Fire Protection Specialists Enclosures Sturdy single and double wall fire protection construction Impact resistant Fast & easy installation Pre-manufactured and modular Available in galvanized, stainless steel & other specialty metals

More information

GC/MS Considerations for Fracking Gases and Water. Dr. Harold McNair Virginia Tech Blacksburg, VA. hmcnair@vt.edu

GC/MS Considerations for Fracking Gases and Water. Dr. Harold McNair Virginia Tech Blacksburg, VA. hmcnair@vt.edu GC/MS Considerations for Fracking Gases and Water Dr. Harold McNair Virginia Tech Blacksburg, VA. hmcnair@vt.edu 1 Outline What is fracking? Energy, Economics, Environmental Factors Chromatographic Considerations

More information

Series AMLDL-Z Up to 1000mA LED Driver

Series AMLDL-Z Up to 1000mA LED Driver FEATURES: Click on Series name for product info on aimtec.com Series Up to ma LED Driver Models Single output Model Input Voltage (V) Step Down DC/DC LED driver Operating Temperature range 4ºC to 85ºC

More information

PowerAmp Design. PowerAmp Design PAD135 COMPACT HIGH VOLATGE OP AMP

PowerAmp Design. PowerAmp Design PAD135 COMPACT HIGH VOLATGE OP AMP PowerAmp Design COMPACT HIGH VOLTAGE OP AMP Rev G KEY FEATURES LOW COST SMALL SIZE 40mm SQUARE HIGH VOLTAGE 200 VOLTS HIGH OUTPUT CURRENT 10A PEAK 40 WATT DISSIPATION CAPABILITY 200V/µS SLEW RATE APPLICATIONS

More information

Process Calibration Tools

Process Calibration Tools Process Calibration Tools A full range of accurate, rugged and reliable calibration solutions for field and bench applications Electrical, Multifunction, and ma Loop Calibration Pressure and Flow Calibration

More information

SOLAR I-V Rel. 1.01 20/07/10

SOLAR I-V Rel. 1.01 20/07/10 PV single phase certifier and I-V curve checker Pag 1 of 5 1. SOLAR I-V MAIN FEATURES SOLAR I-V: use as PV certifier SOLAR I-V performs all tests on Single phase PV plants by using of SOLAR-02 remote unit

More information

Know-how makes the difference. Electrical Actuators

Know-how makes the difference. Electrical Actuators Know-how makes the difference Electrical Actuators With Dansk Ventil Center as your business partner, you are always guaranteed a wide and well sorted product range and a unique technical know-how Product

More information

unit : mm With heat sink (see Pd Ta characteristics)

unit : mm With heat sink (see Pd Ta characteristics) Ordering number: EN1321E Monolithic Linear IC LA4261 3.5 W 2-Channel AF Power Amplifier for Home Stereos and Music Centers Features. Minimum number of external parts required (No input capacitor, bootstrap

More information

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test

More information

HP 70950B OPTICAL SPECTRUM ANALYZER

HP 70950B OPTICAL SPECTRUM ANALYZER HP 71450B, 71451B, and 71452B Optical Spectrum Analyzers Technical Specifications Spectral Measurements from 600 to 1700 nm HP 70950B OPTICAL SPECTRUM ANALYZER OPTICAL INPUT The HP 71450B, 71451B, and

More information

A Simple Current-Sense Technique Eliminating a Sense Resistor

A Simple Current-Sense Technique Eliminating a Sense Resistor INFINITY Application Note AN-7 A Simple Current-Sense Technique Eliminating a Sense Resistor Copyright 998 A SIMPE CURRENT-SENSE TECHNIQUE EIMINATING A SENSE RESISTOR INTRODUCTION A sense resistor R S,

More information

WCAP-CSGP Ceramic Capacitors

WCAP-CSGP Ceramic Capacitors A Dimensions: [mm] B Recommended land pattern: [mm] D1 Electrical Properties: Properties Test conditions Value Unit Tol. Capacitance 1±0.2 Vrms, 1 khz ±10% C 15000 pf ± 10% Rated voltage Dissipation factor

More information

nvision Reference Recorder

nvision Reference Recorder nvision Reference Recorder Your Multi-Purpose Recorder Key Features Records 1 Million Data Points Simple to Use Intuitive keypad takes seconds to learn. Live Data Graphing Robust Drop tested from 5 feet.

More information

Practical Application of Industrial Fiber Optic Sensing Systems

Practical Application of Industrial Fiber Optic Sensing Systems Practical Application of Industrial Fiber Optic Sensing Systems John W. Berthold and David B. Needham Davidson Instruments, Inc. P.O. Box 130100, The Woodlands, TX 77393 ABSTRACT In this presentation,

More information

Rusty Walker, Corporate Trainer Hill PHOENIX

Rusty Walker, Corporate Trainer Hill PHOENIX Refrigeration 101 Rusty Walker, Corporate Trainer Hill PHOENIX Compressor Basic Refrigeration Cycle Evaporator Condenser / Receiver Expansion Device Vapor Compression Cycle Cooling by the removal of heat

More information

LM134-LM234 LM334 THREE TERMINAL ADJUSTABLE CURRENT SOURCES. OPERATES from 1V to 40V

LM134-LM234 LM334 THREE TERMINAL ADJUSTABLE CURRENT SOURCES. OPERATES from 1V to 40V LM134-LM234 LM334 THREE TERMINAL USTABLE CURRENT SOURCES OPERATES from 1 to 40. 0.02% CURRENT REGULATION PROGRAMMABLE from 1µA to 10mA ±3% INITIAL ACCURACY DESCRIPTION The LM134/LM234/LM334 are 3-terminal

More information

Performance and Approvals Testing - ISO/IEC 17025 Application Document

Performance and Approvals Testing - ISO/IEC 17025 Application Document Performance and Approvals Testing - ISO/IEC 17025 Application Document March 2013 Copyright National Association of Testing Authorities, Australia 2013 This publication is protected by copyright under

More information

ENERGY STAR Program Requirements Product Specification for Data Center Storage. Draft 2 Test Method March 2013

ENERGY STAR Program Requirements Product Specification for Data Center Storage. Draft 2 Test Method March 2013 ENERGY STAR Program Requirements Product Specification for Data Center Storage Draft 2 Test Method March 2013 1 2 3 4 1 OVERVIEW The following test method shall be used for determining compliance with

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals

More information

DATA SHEET. TDA8560Q 2 40 W/2 Ω stereo BTL car radio power amplifier with diagnostic facility INTEGRATED CIRCUITS. 1996 Jan 08

DATA SHEET. TDA8560Q 2 40 W/2 Ω stereo BTL car radio power amplifier with diagnostic facility INTEGRATED CIRCUITS. 1996 Jan 08 INTEGRATED CIRCUITS DATA SHEET power amplifier with diagnostic facility Supersedes data of March 1994 File under Integrated Circuits, IC01 1996 Jan 08 FEATURES Requires very few external components High

More information

Gas Custody Transfer Calibration

Gas Custody Transfer Calibration Gas Custody Transfer Calibration Using multi variable temperature / pressure calibrators for flowmeter calibration 2013 Introduction Gas custody transfer flow computers require special calibration to perform

More information

Model UT58A/B/C: OPERATING MANUAL

Model UT58A/B/C: OPERATING MANUAL Table of Contents Title Page Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons Display Symbols

More information

Baseband delay line QUICK REFERENCE DATA

Baseband delay line QUICK REFERENCE DATA FEATURES Two comb filters, using the switched-capacitor technique, for one line delay time (64 µs) Adjustment-free application No crosstalk between SECAM colour carriers (diaphoty) Handles negative or

More information

SECTION 13. Multipliers. Outline of Multiplier Design Process:

SECTION 13. Multipliers. Outline of Multiplier Design Process: SECTION 13 Multipliers VMI manufactures many high voltage multipliers, most of which are custom designed for specific requirements. The following information provides general information and basic guidance

More information

DATA SHEET. TDA1518BQ 24 W BTL or 2 x 12 watt stereo car radio power amplifier INTEGRATED CIRCUITS

DATA SHEET. TDA1518BQ 24 W BTL or 2 x 12 watt stereo car radio power amplifier INTEGRATED CIRCUITS INTEGRATED CIRCUITS DATA SHEET File under Integrated Circuits, IC01 July 1994 GENERAL DESCRIPTION The is an integrated class-b output amplifier in a 13-lead single-in-line (SIL) plastic power package.

More information

Nikon s DigiMicro Position Encoders Nanometer Resolution with Sub-Micron Accuracy

Nikon s DigiMicro Position Encoders Nanometer Resolution with Sub-Micron Accuracy Nikon s DigiMicro Position Encoders Nanometer Resolution with Sub-Micron Accuracy Available in North America through NanoWave, Inc. The DigiMicro Family The DigiMicro product line from Nikon is a family

More information

RPS 8000. High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

RPS 8000. High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features: GE Measurement & Control Solutions RPS 8000 High Accuracy Resonant Pressure Sensor For over 35 years, Druck has manufactured precision pressure sensors with a capability to meet critical applications in

More information

ELECTROMAGNETIC DISC BRAKES

ELECTROMAGNETIC DISC BRAKES ELECTROMAGNETIC DISC BRAKES TYPE 66E 15/30 52.121 Hand release Lining wear adjustment Torque adjustment 4 holes ø13 DISC SIZE Ø A Braking torque Nm Regulated from (40-100%) Reaction on the shaft N Control

More information

R=Required by Lab S=May be subcontracted IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES

R=Required by Lab S=May be subcontracted IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES IEC SYSTEM FO CONFOMITY TESTING AND CETIFICATION OF ELECTICAL EQUIPMENT COMMITTEE OF TESTING LABOATOIES TESTING AND MEASUING EQUIPMENT/ALLOWED SUBCONTACTING Power cables with extruded insulation and their

More information

Multi-Range Programmable DC Power Supplies 9115 Series

Multi-Range Programmable DC Power Supplies 9115 Series Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,

More information

DGA - Method in the Past and for the Future

DGA - Method in the Past and for the Future DGA - Method in the Past and for the Future Page 2 May 2012 1970 1973 Doerenburg introduced the differentiation between electrical and thermal failure mode and introduced ratios for fault gases with similar

More information

Temperature Transmitters ZTT series

Temperature Transmitters ZTT series BT.11.13 ZT/E Transmitters ZTT series The ZTT Series transmitters accept the most commonly used temperature sensors (TC and RTD), as well as mv and slidewire feedback signals. All ZTT transmitters provide

More information

Fluxi 2000/TZ Turbine Gas Meter

Fluxi 2000/TZ Turbine Gas Meter Gas Fluxi 2000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas.

More information

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO The Breather Box High Performance Grade-D Breathing Air Filtration system Specifications Filter change Indicators Incoming Air Plug 1/2 Industrial Interchange 2 Automatic Drains with Discharge tubes 3

More information

PRECISION I RELIABILITY I PERFORMANCE. Cryogenic Testing. Experience a new level of performance

PRECISION I RELIABILITY I PERFORMANCE. Cryogenic Testing. Experience a new level of performance PRECISION I RELIABILITY I PERFORMANCE Cryogenic Testing Experience a new level of performance Contents Cryogenic testing overview 01 Severn Glocon Cryogenic valves at customer installations 02 Performance

More information

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu, APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP

More information

Fluke 2638A Hydra Series III Data Acquisition System/ Digital Multimeter

Fluke 2638A Hydra Series III Data Acquisition System/ Digital Multimeter Fluke 2638A Hydra Series III Data Acquisition System/ Digital Multimeter Technical Data Price-performance breakthrough in a stand-alone data acquisition system The Fluke Hydra Series III continues the

More information

RITTER Multiple Sonic Nozzle Calibration System

RITTER Multiple Sonic Nozzle Calibration System RITTER Multiple Sonic Nozzle Calibration System »Wouldn t it be great to eliminate doubtful measurement results by using proven measurement technology? Providing the most precise results ensures and increases

More information

3. ELECTRICAL PERFORMANCE PROPERTY TEST CONDITION PERFORMANCE 3. 1 Contact Resistance 1) Center Push 100mΩ Max

3. ELECTRICAL PERFORMANCE PROPERTY TEST CONDITION PERFORMANCE 3. 1 Contact Resistance 1) Center Push 100mΩ Max 1. GENERAL 1. 1 Application : This specification is applied to MULTI WAY SWITCH for electronic equipment. 1. 2 Operating Temperature Range :-25 ~ 70 1. 3 Storage Temperature Range :-0 ~ 85. However, 96

More information

Michelin North America

Michelin North America www.centecinc.com SC Telephone: 864.527.7750 Outside SC: 800.227.0855 Michelin North America Industrial Maintenance Technical Interview Outline Industrial Maintenance Technical Interview Outline The Technical

More information

SUCCESS EPCOS Capacitors

SUCCESS EPCOS Capacitors SUCCESS EPCOS Inc. Capacitors Group April, 2012 EV / HV / E-Mobility Battery charger system & Inverter On Board and Off Board Assembly Trend: Wireless Charging DC/DC Converter Filtering DC Link E-Mobility

More information

Take total control of your HVAC system with cost-saving flow and thermal energy meters

Take total control of your HVAC system with cost-saving flow and thermal energy meters Take total control of your HVAC system with cost-saving flow and thermal energy meters Because you can t manage what you don t measure usa.siemens.com/pi Answers for Industry. Contents Introduction 03

More information

Fossil fuel heating equipment

Fossil fuel heating equipment Fossil fuel heating equipment principles and troubleshooting techniques Application Note This application note was written to provide you with an understanding of the basic principles of fossil fuel heating

More information

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W T5 TC-DEL TC-SEL TC-TEL TC-DD PC BASIC, 4 28 W Electronic ballast for system output < 25 W Product description CELMA Energy Efficiency Index A2 / A3 Nominal life time up to 50,000 h (at ta 50 C with a

More information

METRA 22 26S/M Analog-Digital Multimeters with Signal Generator

METRA 22 26S/M Analog-Digital Multimeters with Signal Generator 3-349-026-03 5/7.01 METRAHit 22/23/24/25/26 Precision multimeter (V, db,, F, Hz, C/ F) Resolution: 10 V, 10 m Integrated quartz movement for MIN-MAX recording with reference to real-time Signal generator

More information

INTA Renewable Energy Area activities

INTA Renewable Energy Area activities INSTITUTO NACIONAL DE TECNICA AEROESPACIAL 1. Introduction INTA Renewable Energy Area activities INTA, the National Institute for Aerospace Technology in Spain, is a public agency devoted to aerospace

More information

MODEL 1211 CURRENT PREAMPLEFIER

MODEL 1211 CURRENT PREAMPLEFIER MODEL 1211 CURRENT PREAMPLEFIER Phone: (607)539-1108 Email: info@dlinstruments.com www.dlinstruments.com The Model 1211 Current Preamplifier was designed to provide all of the features required of a modern

More information

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give

More information

Medical Air Systems: Scroll

Medical Air Systems: Scroll GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing

More information

OVERVIEW AUTOMATION SERVICES

OVERVIEW AUTOMATION SERVICES OVERVIEW AUTOMATION SERVICES An Introduction to Automation Automation refers to the software developed to acquire measurements, monitor sensors, automatically calibrate instruments, control equipment and

More information

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION 2099 Ninth Avenue Ronkonkoma, NY 11779 www.vacuuminst.com Smart Charge II An advanced gas backfill and evacuation system with built-in gross leak test.

More information

DATA SHEET. TDA1510AQ 24 W BTL or 2 x 12 W stereo car radio power amplifier INTEGRATED CIRCUITS

DATA SHEET. TDA1510AQ 24 W BTL or 2 x 12 W stereo car radio power amplifier INTEGRATED CIRCUITS INTEGRATED CIRCUITS DATA SHEET 24 W BTL or 2 x 12 W stereo car radio File under Integrated Circuits, IC01 January 1992 GENERAL DESCRIPTION The is a class-b integrated output amplifier encapsulated in a

More information

TDA2040. 20W Hi-Fi AUDIO POWER AMPLIFIER

TDA2040. 20W Hi-Fi AUDIO POWER AMPLIFIER 20W Hi-Fi AUDIO POWER AMPLIFIER DESCRIPTION The TDA2040 is a monolithic integrated circuit in Pentawatt package, intended for use as an audio class AB amplifier. Typically it provides 22W output power

More information

HR-200/300/400/500 Series

HR-200/300/400/500 Series Test Equipment Rockwell Hardness Testing Machines HR-200/300/400/500 Series Bulletin No. 2025 Four economical Rockwell Hardness Testing Machines to HR-210MR Order No. 963-220-10A Rockwell Hardness Testing

More information

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to8. 150 PSI : 10 to 24

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to8. 150 PSI : 10 to 24 Type series booklet 8448.1/2-EN--US ISORIA Centered disc butterfly valves with AMRING elastomer liner 240 PSI: 1½ to8 150 PSI : 10 to 24 Design in accordance with ISO 10631 Manual, electrical, pneumatical

More information