GROUND IMPROVEMENT USING THE VIBRO-STONE COLUMN TECHNIQUE
|
|
|
- Collin Hoover
- 9 years ago
- Views:
Transcription
1 THE INSTITUTION OF ENGINEERS OF IRELAND GROUND IMPROVEMENT USING THE VIBRO-STONE COLUMN TECHNIQUE Bryan A. McCabe BA BAI PhD CEng MIEI Lecturer, Department of Civil Engineering, National University of Ireland, Galway. James A. McNeill BSc MSc CGeol FGS Regional Manager, Keller Ground Engineering, Belfast. Jonathan A. Black BEng PhD MICE Lecturer, School of Engineering, University of Plymouth. Paper presented to a joint meeting of Engineers Ireland West Region and the Geotechnical Society of Ireland, NUI Galway, 15 th March 2007 ABSTRACT: The Vibro Stone Column technique is one of the most widely-used ground improvement processes in the world, although its potential for improving Irish sites has yet to be fully exploited. Historically the system has been used to densify loose granular soils, but over the past 35 years, the system has been used increasingly to reinforce soft cohesive soils and mixed fills. This paper will describe the technique, applicable soil types, settlement and bearing capacity calculations, recent research areas and an Irish case study. 1
2 1. INTRODUCTION Vibro-Flotation is a collective term for forms of ground improvement brought about by inserting a vibrating poker into the ground, and includes Vibro-Compaction and Vibro-Replacement. The latter process is often referred to as (Vibro-) Stone Columns. The commercial promise of Vibro-Compaction was realised with German river-borne granular soils in the 1930s, but it was not until the 1960s that Stone Columns were deployed for improving cohesive soils. Stone Columns were first used in Ireland in the 1970s. The technique is continuing to gain popularity today due to the considerable savings to cost and programme schedule that it can offer over conventional piling solutions in many circumstances. The Vibro-Replacement process is discussed in this paper along with a description of the mechanism of stone column behaviour under load and associated design philosophies. A checklist for the use of stone columns in marginal ground conditions and some practical findings from recent research programmes are also presented. Ample references are provided for those interested in engaging with the topic in more detail. 2. VIBRO-COMPACTION AND VIBRO- REPLACEMENT Vibro-Flotation is performed with a vibrating poker device which can penetrate to the required treatment depth under the action of its own vibrations, assisted by the pull-down winch facility of the rig. The vibrations imparted to the ground are predominantly horizontal and will increase the relative density of soil if the granular content is greater than 90% (see Figure 1). This process is referred to as Vibro- Compaction, and has been used to compact loose sands to depths of 30m, such as in The World and Palm Island Projects off the Dubai coast and Edinburgh s Leith Docks. However, the vibrations themselves have minimal effect on cohesive soils (clays and silts), so in these and mixed soils, the penetration of the poker is followed by the construction of a stone column. The displacement of the existing ground by the penetrating poker allows the construction of granular columns with high friction angle, so that the composite soil mass has a greater average strength and stiffness than the untreated ground. The hole created by the poker is filled with inert crushed stone or gravel (or approved construction waste in certain circumstances) and is compacted in stages from the base of the hole upwards. There are two different approaches that may be used to construct the column, depending on the ground conditions. In the Top Feed System, the poker is completely withdrawn after initial penetration to the design depth. Stone (40-75mm in size) is then tipped into the hole in controlled volumes from the ground surface. The column is compacted in layers (the stone is forced downwards and outwards) through continued penetration and withdrawal of the poker. The Top Feed System is suitable if the hole formed by the poker will remain open during construction of the column. Alternatively, the stone may be fed from a rigmounted hopper through a permanent delivery tube along the side of the poker, which bends inwards and allows the stone to exit at the poker tip. This Bottom Feed process requires a smaller grade of stone (15-45mm). By remaining in the ground during column construction, the poker cases its own hole and hence is suited to ground with a high water table or running sand conditions. The Bottom Feed system is shown on the cover photograph, with a schematic illustration of the process shown in Figure 2. In addition to improving bearing capacity and reducing compressibility, stone columns installed in a uniform grid pattern will help homogenise variable soil properties, thereby reducing the potential for differential settlement. Stone columns serve a secondary function of acting as vertical drains, accelerating the dissipation of excess pore water pressures (and associated primary settlement) from the imposed loading, allowing a foundation or floor slab to be brought into service at an early stage. In addition to the savings per metre length that stone columns present over piles, the soft column heads facilitate the use of ground bearing slabs, representing further savings compared to the ground beams and suspended slabs associated with piled solutions. Plate load tests (typically 600mm diameter) are carried out on constructed columns to verify the compactness of the stone and the stiffness of the supporting ground at the top of the column. 2
3 However, settlements measured may not be representative of foundation or slab behaviour due to differences in the load duration and depth to which the ground is stressed. Long term zone load tests provide a truer reflection of the stiffness of the ground, as a plan area the size of a real foundation is loaded which will usually straddle several columns and the intervening untreated ground. However, due to their cost, these are generally reserved for marginal sites. In addition to these control measures, it should be noted that the vibrating poker itself acts as an investigating tool which provides an additional safeguard against unforeseen ground conditions. A measure of the resistance to penetration of the poker is fed back electronically to the rig operator, who can then match the quantity of stone supplied to the lateral resistance of the ground encountered. Key publications which illustrate the Vibro- Compaction and Replacement techniques, the importance of good construction practice and some interesting case histories are Slocombe et al (2000), Bell (2004) and Sondermann and Wehr (2004). 3. BEHAVIOUR AND DESIGN OF STONE COLUMNS Most types of ground improvement are intended to work with the existing ground whereas rigid inclusions (piles) are intended to bypass the ground to some extent. While stone columns will transmit some load to the soil by shear stresses (along the column-soil interface) and end bearing (at the column base), the predominant loadtransfer mechanism (unless the column is very short) is lateral bulging into the surrounding soil. The relevant column stresses are depicted in Figure 3, while Figure 4 illustrates the bulging phenomenon in model granular column tests in clay carried out at the University of Plymouth. The passive resistance of the surrounding soil dictates the column performance under load. Generally the column bulging will be greatest close to the top of the column where the overburden pressures are lowest. Cylindrical Cavity Expansion Theory (CCET) is applied to many geotechnical problems, most notably to the interpretation of the pressuremeter test which measures horizontal stresses in the ground (i.e. Wroth, 1984). CCET has also been used to model the bulging behaviour of granular columns leading to predictions of bearing capacity and settlement performance. Bearing Capacity Hughes and Withers (1974) performed pioneering laboratory studies of sand columns within a cylindrical chamber containing clay, and used radiography to track the deformations occurring within and outside the column. They found that CCET represented the measured column behaviour very well, and proposed that the ultimate vertical stress (q) in a stone column could be predicted by: 1 + sin q = φ ' σ + c ro 4 [1] 1 sinφ' where φ is the friction angle of the stone infill, σ' ro is the free-field lateral effective stress and c is the undrained strength. This equation is widely used in practice today. There are alternative approaches for estimating the bearing capacity of single columns and column groups, such as that recently published by Etezad et al (2006). The authors report an analytical treatment of bearing capacity failure mechanisms. The failure mechanisms adopted are based upon the output from a combination of Finite Element analyses and field trials. Settlement Absolute and differential settlement restrictions usually govern the length and spacing of columns, and the preferred method of estimating post-treatment settlement in European practice was developed by Priebe (1995), again based upon CCET. Although this method is strictly applicable to an infinite array of columns and has some empiricism in its development, it is found to work very well for most applications. Priebe s settlement improvement factor, n, defined as: settlement without treatment n = [2] settlement with treatment is a function of the friction angle of the stone φ, the soil s Poisson s ratio and an Area Replacement Ratio dictated by the column spacing. The area replacement ratio is defined as A c /A, where A c = cross-sectional area of one 3
4 column and A = total cross-sectional area of the unit cell attributed to each column (see Figure 5). A c /A is related geometrically to the column radius (r) and column spacing (s) according to: 2 A r c = k [3] A s where k is π and 2π/ 3 for square and triangular column grids respectively. Beneath footings and strips, it is usually sufficient to determine A c directly as the total foundation area divided by the number of supporting columns. Priebe s basic improvement factor may be derived from the chart shown in Figure 6 (note the reciprocal Area Replacement Ratio A/A c is used). However, corrections should be applied to allow for the compressibility of the column aggregate and influence of the pressure gradient along the soil-column interface; features not catered for in earlier work (Priebe 1976). The method of Baumann and Bauer (1974) is sometimes used in Europe, although it has a weaker theoretical basis than Priebe (1995) and is believed to give poorer settlement predictions for clayey soils (Slocombe, 2001). The approach of Goughnour and Bayuk (1979) is preferred in the United States, although the method is much more complex and the necessary parameters are not readily available from routine Ground Investigations. With the continued development of more realistic constitutive soil models, designated geotechnical Finite Element (FE) software (and 2-D PLAXIS in particular) is being used to model stone column foundations (i.e. Debats et al 2003, Wehr and Herle 2006). The FE method has the particular advantage of allowing the ground improvement scheme to be modelled in unison with the slab or foundation it supports. It is also very useful for unusual situations for which no standard design method exists, such as the composite pile/ground improvement used to support raft foundations at Limehouse Basin in London. Here Continuous Flight Augered (CFA) Piles were constructed to within 3m of the ground surface. Stone columns were constructed from the top of the CFA piles to the ground surface to reinforce and even out variable made ground conditions. 4. SOFT OR MARGINAL GROUND CONDITIONS The construction industry has been buoyant in Ireland over the past 5-10 years, and with the ever increasing pressure to develop marginal sites, there is considerable interest in the applicability of stone columns to cohesive and organic soils. The following checklist may be useful if contemplating a Stone Column ground improvement solution: (i) Organic soils are characterised by high moisture content, plasticity index and compressibility and as a general rule, the higher the organic content, the more difficult it is to arrest settlement in these soils. Most organic silts and clays may be successfully treated. If present in a discrete layer less than 0.6m thick, a stone column may be formed in peat. However, for larger layer thicknesses or multiple thin bands, it is unlikely that the peat will provide adequate passive resistance to confine the column (Mitchell and Jardine 2002). It may be possible to install a dry plug of lean-mix concrete to bridge a compressible peat layer which is in excess of 0.6m in thickness, and this may be installed during the stone column construction process. Geogrids and geotextiles installed around the column s perimeter have also been used to confine columns through weaker strata. (ii) A lower limit to the undrained strength of c u =15kPa is suggested for treatment with stone columns, although there have been situations where softer soils have been successfully improved (Raju et al, 2004, and others). However it is not sufficient to consider the undisturbed strength of cohesive soil alone; the sensitivity of the soil to disturbance (S t ) is equally important: c u undisturbed S t = [4] cu remoulded where c u remoulded is the undrained strength of soil with its natural structure destroyed. Normally consolidated clays are more likely to be sensitive than overconsolidated clays, and while most clays have S t values between 1 and 4, S t may be as high as 150 in the case of the well publicized Scandanavian and Canadian quick clays. Vibrations from a depth vibrator can lead to a considerable loss of strength in very sensitive soils, which can impact upon the trafficability of 4
5 sites, adjacent structures and slope stability. Fortunately, Ireland has few soils in the very sensitive category. (iii) Plasticity Index: The plasticity index (I p ) of a soil reflects the potential for volume change; swelling and shrinkage will not be controlled by adding stone columns. Although the UK National House Building Council (NHBC, 1988) suggests that stone columns should not be used when I p >40%, high plasticity soils can still be improved by stone columns in certain circumstances. (iv) Clay Fill: The self-weight settlement of recent clay fills (or mixed fills containing substantial clay) may be difficult to predict, especially if there has been little control in placement. While installation of stone columns through such fill may accelerate the settlement process, the magnitude of settlement will not be reduced. It is generally adopted practice, from extensive experience, that columns should not be used in clay fill which is less than 10 years in place. Stone columns are of little benefit in loose fills which are susceptible to collapse settlement (such as may be present in back-filled quarry pits). Collapse settlement may arise from firsttime inundation of water directly through the ground surface, from underneath the ground surface (such as a leaking pipe) or from a rising groundwater table. Stone columns may facilitate the passage of water unless suitable precautions are taken. Sudden settlement of the fill would lead to an instant loss of lateral support at the top of the column (Mitchell and Jardine, 2002). 5. RECENT STONE COLUMN RESEARCH Recent innovative and high quality model tests carried out at the University of Glasgow (Muir Wood et al, 2000) and Queens University Belfast (McKelvey et al, 2004, Black et al, 2006) have improved our understanding of stone column behaviour. Details of the apparatus and procedures used may be found in the relevant references, but a summary of the main practical findings is provided here. Muir Wood et al. (2000) conducted what is considered to be the most comprehensive laboratory model investigations of large groups of columns. The results suggest that the prefailure mechanisms and failure modes of column groups are different from those of an isolated column. It was reported that the area replacement ratio (A c /A) influences the extent of column interaction and the load sharing between the columns and intervening ground. The research also claims that significant improvement to bearing capacity requires an area replacement ratio of 25% or greater. Perhaps the most fundamental aspect of this work was the postulation of a realistic group failure mechanism. The deformation patterns in the columns were observed upon excavating the ground around the loaded columns. Columns adjacent to the centre column exhibited the most distortion. This observation is in good agreement with the stress levels measured at this location. Most of the bulging, shearing and lateral deflection occurred within a conical region directly beneath the foundation. The depth of this failure wedge increased as the area replacement ratio increased. A four-part failure mechanism was proposed based upon these observations (Figure 7). A conical zone (Zone 1) exists immediately beneath the footing in which there is no column deformation as the clay itself and confinement of the rigid footing provide adequate passive resistance. In Zone 2 (which is immediately below Zone 1), deformations are plastic and column bulging, shearing and buckling of the columns were all observed. Zone 3 is referred to as the retaining unit which effectively provides lateral support to the failure wedge underneath the footing. Zone 4 represents the extension zone of the mechanism. McKelvey et al (2004) used a transparent medium with clay-like properties to allow visual monitoring of the columns throughout foundation loading. The main findings of this research relate to optimum column aspect ratio L/d (L =column length, d =column diameter). Careful examination of the digital images taken during loading (Figure 8) showed that in the case of short columns (i.e. L/d = 6), bulging took place over the entire length of the columns and they punched into the clay beneath their bases. The long column (L/d = 10) deformed significantly in the upper region whereas the bottom portion remained undeformed. This suggests that there was little or no load transfer to the base in longer columns, with failure 5
6 arising from bulging or shear. McKelvey et al (2004) postulated a critical column length of L=6d, which is in keeping with earlier work (Hughes and Withers, 1974, Muir Wood et al 2000). Black et al (2006) developed a more sophisticated triaxial apparatus in which the boundary conditions imposed on a clay bed (reinforced with stone columns) can be regulated. Publication of this work is pending at the time of writing. The Finite Element method has been used in some academic studies, most using the homogenisation technique (i.e. Lee and Pande, 1998) in which the constitutive models are developed from composite soil properties assigned to the entire reinforced zone. However, the FE Method s potential to address some of the key shortcomings in stone column design has not been harnessed. Collaborative research between NUI Galway s Civil Engineering Department and Keller Ground Engineering aims to use the FE Method in an applied sense to address issues such as: (i) the behaviour of floating columns (or partial depth treatment); Priebe s (1995) formulation assumes that columns are terminated at a rigid layer, and (ii) the extent to which stone columns arrest secondary or creep settlement, which is most prevalent in organic soils. 6. CASE HISTORY Retirement Village, Ballinasloe, Co. Galway At the time of writing, a new retirement village is under construction on the banks of the River Suck in Ballinasloe. The development comprises a two-storey nursing home and a four-storey apartment block, with site levels raised by 1-1.5m for flood protection. Ground conditions at the site are mixed but typically comprise of up to 1.5m of soft organic fill overlying medium dense and dense silty sandy gravel with occasional cobbles and boulders. Rather than piling to depth to support the fourstorey block, a ground improvement solution was implemented whereby the soft organic fill was removed and replaced with clean stone (<75mm), with the same material used to raise site levels. Approximately 700 Vibro Stone Columns were installed from this elevated platform level to depths of up to 4m to densify the new fill and any underlying loose natural soils. Conventional strip foundations were then used, designed for an allowable bearing pressure of 175kN/m 2 in the four-storey block. Floor slabs were also treated. Ironically, the two-storey nursing home has deeper deposits of soft organic clay and peat underneath, needing piled support. The piling system used is referred to as Vibro Concrete Columns (VCCs) and these may be constructed using the same rig as Vibro Stone Columns, with a change of poker. A further description of the VCC technique may be found in McCabe and McNeill (2006). It is not uncommon to use a suitable combination of Vibro Stone Columns and VCCs at one site. 7. CONCLUSIONS The Irish construction industry has been slower than many of its European counterparts to recognise the technical and economic advantages that Vibro Stone Columns can provide. Ireland has an abundance of soft estuarine and alluvial soils and these may be improved sufficiently to allow standard foundations to be constructed at shallow depth, without the need to resort to deep piling. Where ground conditions are suitable, stone column solutions have been shown to be more cost effective than trench fill in excess of 2m depth. In addition, stone columns can offer considerable contract programme savings over other ground improvement methods, such as preloading and vertical drains. As with all geotechnical projects, a thorough site investigation with adequate information on soil strength and compressibility is essential. 8. ACKNOWLEDGEMENTS The authors would like to thank Dr. V. Sivakumar, Queens University Belfast, for information used in preparation of the presentation associated with this written paper. Thanks also to Mr. David Whyte of Keller Ground Engineering and Mr. Eoghan Clifford of NUI Galway for proof reading the paper. 6
7 9. REFERENCES Baumann, V. and Bauer, G.E.A. (1974) The performance of foundations on various soils stabilized by the Vibro-Compaction Method, Canadian Geotechnical Journal, Vol. 11, No. 4, pp Bell, A.L. (2004) The development and importance of construction technique in deep vibratory ground improvement, Proc. Ground and Soil Improvement, Geotechnique Symposium, edited by C.A. Raison, pp Black, J.A., Sivakumar, V., Madhav, M.R. and McCabe, B.A. (2006) An improved experimental test set-up to study the behaviour of granular columns, Geotechnical Testing Journal, ASTM, Vol. 29, No. 3, pp Debats, J.M., Guetif, Z. and Bouassida, M.(2003). Soft soil improvement due to vibrocompacted columns installation. Proceedings of the International Workshop on Geotechnics of Soft-Soils-Theory and Practice, pp Etezad, M., Hanna, A.M. and Ayadat. T. (2006) Bearing capacity of groups of stone columns, Proceedings of the 6 th European Conference on Numerical Methods in Geotechnical Engineering, Graz, pp Goughnour, R.R. and Bayuk, A.A. (1979) Analysis of stone column soil matrix interaction under vertical load, Proceedings of the International Conference on Soil Reinforcements, Paris, pp Hughes, J.M.O. and Withers, N.J. (1974) Reinforcing of soft cohesive soils with stone columns, Ground Engineering, Vol. 7, No. 3, pp Lee, J.S. and Pande, G.N. (1998), Analysis of Stone Column Reinforced Foundations, International. Journa of Numerical and Analytical Methods in Geomechanics, Vol. 22, pp McCabe, B.A. and McNeill, J.A. (2006) Vibro Techniques for Ground Improvement in Ireland, The Engineers Journal, Vol. 60, Issue 3 (April), pp McKelvey, D., Sivakumar, V., Bell, A. and Graham, J. (2004) Modelling vibrated stone columns in soft clay, Proceedings of the Institute of Civil Engineers Geotechnical Engineering, Vol. 157, Issue GE3, pp Mitchell, J.M. and Jardine, F.M. (2002) A guide to ground treatment, CIRIA Publication C572. Muir Wood, D., Hu, W. and Nash, D.F.T. (2000) Group effects in stone column foundations model tests, Geotechnique, Vol. 50, No. 6, pp NHBC (1988) National House Building Council Standards, Vibratory ground improvement techniques (Chapter 4.6). Priebe, H.J. (1976) Evaluation of the settlement reduction of a foundation improved by Vibro- Replacement, Bautechnik, No. 5, pp (in German) Priebe, H.J. (1995) The design of Vibro Replacement, Ground Engineering (Dec), pp Raju, V.R., Hari Krishna, R. and Wegner, R. (2004) Ground improvement using Vibro Replacement in Asia 1994 to 2004 a 10 year review, Proceedings of 5 th Int. Conf. on Ground Improvement Techniques, Kuala Lumpur, Malaysia. Slocombe, B.C. (2001) Deep compaction of problematic soils, Problematic Soils, Thomas Telford (London), pp Slocombe, B.C., Bell, A.L. and Baez, J.I. (2000) The densification of granular soil using Vibro methods, Geotechnique, Vol. L, No. 6, pp Sondermann, W. and Wehr, W. (2004) Deep Vibro techniques, Ground Improvement, 2 nd Edition, edited by M.P. Moseley and K. Kirsch, pp 57-92, Spon Press. Wehr, J. and Herle, I. (2006) Exercise on calculation of stone columns - Priebe method and FEM, Proceedings of the 6 th European Conference on Numerical Methods in Geotechnical Engineering, Graz, pp Wroth, C.P. (1984) The interpretation of in situ soil tests, Geotechnique, Vol. 34, No. 4, pp
8 Soil type Bearing pressure (kpa) Settlement (mm) Made Ground: mixed cohesive and granular Made Ground: Granular fill, ash, brick, rubble etc Natural sands or sands and gravels Soft Alluvial Clays Table 1: Bearing pressures and settlements ranges after vibratory stabilisation for normal foundations (after Slocombe, 2001) Figure 1: Particle size distribution illustrating applicability of Vibro-Compaction and Vibro-Replacement 8
9 Figure 2: Bottom Feed method of stone column construction Figure 3: Mechanisms of load transfer for (a) a rigid pile and (b) a stone column (after Hughes and Withers 1974) 9
10 Figure 4: Model tests on stone column showing characteristic bulging behaviour (Plymouth University) column radius = r, column area = A c s s s Area per column = A (Unit Cell) Figure 5: Typical column arrangements, triangular grid (left) and square grid (right) 10
11 Basic Improvement Factor, n φ'= φ'=35 0 φ'=45 0 φ'= φ'=40 0 φ' = angle of internal friction of the column material Curves shown for Poisson's Ratio υ=1/ Reciprocal Area Improvement Ratio A/A c Figure 6: Priebe s basic improvement factor (reproduced from Priebe, 1995) Figure 7: Four-zone failure mechanism proposed by Muir Wood et al (2000) for stone column groups 11
12 Figure 8: Photographs of sand columns beneath circular footing, before, during and after loading (a) L/d=6, (b) L/d=10, (McKelvey et al, 2004) 12
Ground improvement using the vibro-stone column technique
Ground improvement using the vibro-stone column technique A. Kosho 1 A.L.T.E.A & Geostudio 2000, Durres, Albania ABSTRACT The vibro stone columns technique is one of the most used techniques for ground
PILE FOUNDATIONS FM 5-134
C H A P T E R 6 PILE FOUNDATIONS Section I. GROUP BEHAVIOR 6-1. Group action. Piles are most effective when combined in groups or clusters. Combining piles in a group complicates analysis since the characteristics
Numerical Simulation of CPT Tip Resistance in Layered Soil
Numerical Simulation of CPT Tip Resistance in Layered Soil M.M. Ahmadi, Assistant Professor, [email protected] Dept. of Civil Engineering, Sharif University of Technology, Tehran, Iran Abstract The paper
Module 7 (Lecture 24 to 28) RETAINING WALLS
Module 7 (Lecture 24 to 28) RETAINING WALLS Topics 24.1 INTRODUCTION 24.2 GRAVITY AND CANTILEVER WALLS 24.3 PROPORTIONING RETAINING WALLS 24.4 APPLICATION OF LATERAL EARTH PRESSURE THEORIES TO DESIGN 24.5
SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT
SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT 1.0 SOIL IMPROVEMENT 1.1 General Soil Investigation Information are provided in Part B1 annex as a guide to the Contractor for his consideration
Program COLANY Stone Columns Settlement Analysis. User Manual
User Manual 1 CONTENTS SYNOPSIS 3 1. INTRODUCTION 4 2. PROBLEM DEFINITION 4 2.1 Material Properties 2.2 Dimensions 2.3 Units 6 7 7 3. EXAMPLE PROBLEM 8 3.1 Description 3.2 Hand Calculation 8 8 4. COLANY
Washington 98102-3699, [email protected]
LESSONS LEARNED FROM A STONE COLUMN TEST PROGRAM IN GLACIAL DEPOSITS Barry S. Chen 1, P.E., Member, Geo-Institute and Michael J. Bailey 2, P.E., Member, Geo-Institute ABSTRACT A stone column test program
Appendix A Sub surface displacements around excavations Data presented in Xdisp sample file
Appendix A Sub surface displacements around excavations Data presented in Xdisp sample file Notation B1 = lowest level of basement slab c = cohesion E = drained Young s Modulus Eu = undrained Young s Modulus
Drained and Undrained Conditions. Undrained and Drained Shear Strength
Drained and Undrained Conditions Undrained and Drained Shear Strength Lecture No. October, 00 Drained condition occurs when there is no change in pore water pressure due to external loading. In a drained
c. Borehole Shear Test (BST): BST is performed according to the instructions published by Handy Geotechnical Instruments, Inc.
Design Manual Chapter 6 - Geotechnical 6B - Subsurface Exploration Program 6B-2 Testing A. General Information Several testing methods can be used to measure soil engineering properties. The advantages,
NUMERICAL MODELLING OF PIEZOCONE PENETRATION IN CLAY
NUMERICAL MODELLING OF PIEZOCONE PENETRATION IN CLAY Ilaria Giusti University of Pisa [email protected] Andrew J. Whittle Massachusetts Institute of Technology [email protected] Abstract This paper
CIVL451. Soil Exploration and Characterization
CIVL451 Soil Exploration and Characterization 1 Definition The process of determining the layers of natural soil deposits that will underlie a proposed structure and their physical properties is generally
GUIDELINE FOR HAND HELD SHEAR VANE TEST
GUIDELINE FOR HAND HELD SHEAR VANE TEST NZ GEOTECHNICAL SOCIETY INC August 2001 CONTENTS Page 1.0 Introduction 2 2.0 Background 2 3.0 Recommended Practice 3 4.0 Undrained Shear Strength 3 5.0 Particular
INTRODUCTION TO SOIL MODULI. Jean-Louis BRIAUD 1
INTRODUCTION TO SOIL MODULI By Jean-Louis BRIAUD 1 The modulus of a soil is one of the most difficult soil parameters to estimate because it depends on so many factors. Therefore when one says for example:
Specification Guidelines: Allan Block Modular Retaining Wall Systems
Specification Guidelines: Allan Block Modular Retaining Wall Systems The following specifications provide Allan Block Corporation's typical requirements and recommendations. At the engineer of record's
How To Design A Foundation
The Islamic university - Gaza Faculty of Engineering Civil Engineering Department CHAPTER (2) SITE INVESTIGATION Instructor : Dr. Jehad Hamad Definition The process of determining the layers of natural
ESTIMATION OF UNDRAINED SETTLEMENT OF SHALLOW FOUNDATIONS ON LONDON CLAY
International Conference on Structural and Foundation Failures August 2-4, 2004, Singapore ESTIMATION OF UNDRAINED SETTLEMENT OF SHALLOW FOUNDATIONS ON LONDON CLAY A. S. Osman, H.C. Yeow and M.D. Bolton
GEOTECHNICAL ENGINEERING FORMULAS. A handy reference for use in geotechnical analysis and design
GEOTECHNICAL ENGINEERING FORMULAS A handy reference for use in geotechnical analysis and design TABLE OF CONTENTS Page 1. SOIL CLASSIFICATION...3 1.1 USCS: Unified Soil Classification System...3 1.1.1
EN 1997-1 Eurocode 7. Section 10 Hydraulic Failure Section 11 Overall Stability Section 12 Embankments. Trevor L.L. Orr Trinity College Dublin Ireland
EN 1997 1: Sections 10, 11 and 12 Your logo Brussels, 18-20 February 2008 Dissemination of information workshop 1 EN 1997-1 Eurocode 7 Section 10 Hydraulic Failure Section 11 Overall Stability Section
Soil Mechanics. Outline. Shear Strength of Soils. Shear Failure Soil Strength. Laboratory Shear Strength Test. Stress Path Pore Pressure Parameters
Soil Mechanics Shear Strength of Soils Chih-Ping Lin National Chiao Tung Univ. [email protected] 1 Outline Shear Failure Soil Strength Mohr-Coulomb Failure Criterion Laboratory Shear Strength Test
STRUCTURAL DAMAGE OF A 5-STOREY BUILDING: DIFFERENTIAL SETTLEMENT DUE TO CONSTRUCTION OF AN ADJACENT BUILDING OR BECAUSE OF CONSTRUCTION DEFECTS?
STRUCTURAL DAMAGE OF A 5-STOREY BUILDING: DIFFERENTIAL SETTLEMENT DUE TO CONSTRUCTION OF AN ADJACENT BUILDING OR BECAUSE OF CONSTRUCTION DEFECTS? Ioannis Anastasopoulos National Technical University of
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS While its use is not required, this checklist has been prepared to provide the field inspector a summary
FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples
FOUNDATION DESIGN Proportioning elements for: Transfer of seismic forces Strength and stiffness Shallow and deep foundations Elastic and plastic analysis Foundation Design 14-1 Load Path and Transfer to
Module 5 (Lectures 17 to 19) MAT FOUNDATIONS
Module 5 (Lectures 17 to 19) MAT FOUNDATIONS Topics 17.1 INTRODUCTION Rectangular Combined Footing: Trapezoidal Combined Footings: Cantilever Footing: Mat foundation: 17.2 COMMON TYPES OF MAT FOUNDATIONS
SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)
Page 1 of 7 STONE STRONG SYSTEMS SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised ) PART 1: GENERAL 1.01 Description A. Work includes furnishing and installing precast modular blocks
CEEN 162 - Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests
PURPOSE: The parameters of the shear strength relationship provide a means of evaluating the load carrying capacity of soils, stability of slopes, and pile capacity. The direct shear test is one of the
Dimensional and Structural Data for Elliptical Pipes. PD 26 rev D 21/09/05
Dimensional and Structural Data for Elliptical Pipes 21/09/05 Page 1 of 15 1. Foreword This document details a method for the structural design of Stanton Bonna Elliptical pipes for the common conditions
Interpretation of clogging effects on the hydraulic behavior of ion treated geotextiles
9 th International Conference on Geosynthetics, Brazil, 2010 Interpretation of clogging effects on the hydraulic behavior of ion treated geotextiles Lee, K. W. Department of Civil Engineering, Dongseo
Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing
Brussels, 18-20 February 2008 Dissemination of information workshop 1 Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing Dr.-Ing. Bernd Schuppener, Federal Waterways Engineering
CHAPTER 9 FEM MODELING OF SOIL-SHEET PILE WALL INTERACTION
391 CHAPTER 9 FEM MODELING OF SOIL-SHEET PILE WALL INTERACTION 9.1 OVERVIEW OF FE SOIL-STRUCTURE INTERACTION Clough and Denby (1969) introduced Finite Element analysis into the soil-structure interaction
Determination of Thermal Conductivity of Coarse and Fine Sand Soils
Proceedings World Geothermal Congress Bali, Indonesia, - April Determination of Thermal Conductivity of Coarse and Fine Sand Soils Indra Noer Hamdhan 1 and Barry G. Clarke 2 1 Bandung National of Institute
DFI CSCE Workshop April 12, 2013 Solutions for Embankments Over Soft Soils Embankments Over Soft Soils
DFI CSCE Workshop April 12, 2013 Solutions for Embankments Over Soft Soils Embankments Over Soft Soils Construction over Unstable Soils focuses on methods to support embankment and embankment widening
EVALUATING THE IMPROVEMENT FROM IMPACT ROLLING ON SAND
EVALUATING THE IMPROVEMENT FROM IMPACT ROLLING ON SAND D.L. Avalle, Broons Hire (SA) Pty Ltd, Australia J.P. Carter, The University of Sydney, Australia Abstract Impact rolling, utilising a non-circular
Soils, Foundations & Moisture Control
Soils, Foundations & Moisture Control Soil The top loose layer mineral and/or organic material on the surface of the Earth that serves as a natural medium for the growth of plants and support for the foundations
Ohio Department of Transportation Division of Production Management Office of Geotechnical Engineering. Geotechnical Bulletin PLAN SUBGRADES
Ohio Department of Transportation Division of Production Management Office of Geotechnical Engineering Geotechnical Bulletin GB 1 PLAN SUBGRADES Geotechnical Bulletin GB1 was jointly developed by the Offices
PVC PIPE PERFORMANCE FACTORS
PVC PIPE PERFORMANCE FACTORS PVC pipe, like all flexible pipe products, is very dependent on the surrounding soil for its structural capacity, in addition, the pipe material must have sufficient inherent
CPTic_CSM8. A spreadsheet tool for identifying soil types and layering from CPTU data using the I c method. USER S MANUAL. J. A.
CPTic_CSM8 A spreadsheet tool for identifying soil types and layering from CPTU data using the I c method. USER S MANUAL J. A. Knappett (2012) This user s manual and its associated spreadsheet ( CPTic_CSM8.xls
LABORATORY CLASSIFICATION OF SOILS FOR ENGINEERING PURPOSES
Test Procedure for LABORATORY CLASSIFICATION OF SOILS FOR ENGINEERING PURPOSES TxDOT Designation: Tex-142-E Effective Date: August 1999 1. SCOPE 1.1 This method is a system for classifying disturbed and
Site Investigation. Some unsung heroes of Civil Engineering. buried right under your feet. 4. Need good knowledge of the soil conditions
This is an attempt to create a stand alone self learning module on site investigation. Fasten your seat belts. Sit back, relax and enjoy. 1 2 Site Investigation Some unsung heroes of Civil Engineering
Worked Example 2 (Version 1) Design of concrete cantilever retaining walls to resist earthquake loading for residential sites
Worked Example 2 (Version 1) Design of concrete cantilever retaining walls to resist earthquake loading for residential sites Worked example to accompany MBIE Guidance on the seismic design of retaining
KWANG SING ENGINEERING PTE LTD
KWANG SING ENGINEERING PTE LTD 1. INTRODUCTION This report represents the soil investigation works at Aljunied Road / Geylang East Central. The objective of the soil investigation is to obtain soil parameters
CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST
CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST 1 Permeability is a measure of the ease in which water can flow through a soil volume. It is one of the most important geotechnical parameters. However,
A Ground Improvement Update from TerraSystems
TERRANOTES A Ground Improvement Update from TerraSystems SOIL MODULUS AFTER GROUND IMPROVEMENT Evaluation of ground improvement is accomplished using a variety of methods, from simple elevation surveys
APPENDIX A PRESSUREMETER TEST INTERPRETATION
APPENDIX A PRESSUREMETER TEST INTERPRETATION PRESSUREMETER TEST INTERPRETATION Description of test The pressuremeter test, discussed in great detail by Martin (1977), Baguelin et al. (1978), Barksdale
SHAFT CONSTRUCTION IN TORONTO USING SLURRY WALLS
SHAFT CONSTRUCTION IN TORONTO USING SLURRY WALLS Vince Luongo Petrifond Foundation Co., Ltd. PROJECT DESCRIPTION The York Durham Sanitary System (YDSS) Interceptor in the Town of Richmond Hill located
Soil Mechanics SOIL STRENGTH page 1
Soil Mechanics SOIL STRENGTH page 1 Contents of this chapter : CHAPITRE 6. SOIL STRENGTH...1 6.1 PRINCIPAL PLANES AND PRINCIPAL STRESSES...1 6.2 MOHR CIRCLE...1 6.2.1 POLE METHOD OF FINDING STRESSES ON
CW 3110 SUB-GRADE, SUB-BASE AND BASE COURSE CONSTRUCTION TABLE OF CONTENTS
December 2014 CW 3110 SUB-GRADE, SUB-BASE AND BASE COURSE CONSTRUCTION TABLE OF CONTENTS 1. DESCRIPTION... 1 1.1 General... 1 1.2 Definitions... 1 1.3 Referenced Standard Construction Specifications...
Improvement in physical properties for ground treated with rapid impact compaction
International Journal of the Physical Sciences Vol. 6(22), pp. 5133-5140, 2 October 2011 Available online at http://www.academicjournals.org/ijps ISSN 1992-1950 2011 Academic Journals Full Length Research
product manual HS-4210 HS-4210_MAN_09.08 Digital Static Cone Penetrometer
HS-4210_MAN_09.08 product manual HS-4210 Digital Static Cone Penetrometer Introduction This Manual covers the measurement of bearing capacity using the Humboldt Digital Static Cone Penetrometer (DSCP).
Soil behaviour type from the CPT: an update
Soil behaviour type from the CPT: an update P.K. Robertson Gregg Drilling & Testing Inc., Signal Hill, California, USA ABSTRACT: An initial application of CPT results is to evaluate soil type and soil
By D. P. StewarP and M. F. Randolph z
T-BAR PENETRATION TESTING IN SOFT CLAY By D. P. StewarP and M. F. Randolph z ABSTRACT: A t-bar penetration test for soft clay that can be performed with existing cone penetration test (CPT) equipment is
Comprehensive Design Example 2: Foundations for Bulk Storage Facility
Comprehensive Design Example 2: Foundations for Bulk Storage Facility Problem The project consists of building several dry product storage silos near an existing rail siding in an open field presently
Module 1 : Site Exploration and Geotechnical Investigation. Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives
Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives In this section you will learn the following Penetrometer Tests Standard penetration test Static cone penetration test Dynamic cone
How To Prepare A Geotechnical Study For A Trunk Sewer Project In Lincoln, Nebraska
APPENDIX B Geotechnical Engineering Report GEOTECHNICAL ENGINEERING REPORT Preliminary Geotechnical Study Upper Southeast Salt Creek Sanitary Trunk Sewer Lincoln Wastewater System Lincoln, Nebraska PREPARED
Geotechnical Investigation Reports and Foundation Recommendations - Scope for Improvement - Examples
Geotechnical Investigation Reports and Foundation Recommendations - Scope for Improvement - Examples Prof. V.S.Raju (Formerly: Director, IIT Delhi & Professor and Dean, IIT Madras) Email: [email protected]
REINFORCED CONCRETE. Reinforced Concrete Design. A Fundamental Approach - Fifth Edition. Walls are generally used to provide lateral support for:
HANDOUT REINFORCED CONCRETE Reinforced Concrete Design A Fundamental Approach - Fifth Edition RETAINING WALLS Fifth Edition A. J. Clark School of Engineering Department of Civil and Environmental Engineering
Tremie Concrete CM 420 CM 420 CM 420 CM 420. Temporary Structures. Tremie Concrete
Tremie Concrete Underwater concrete plays an important role in the construction of offshore structures. It may be used to tie together various elements in composite action (i.e., to tie piling to the footing).
4.3 Results... 27 4.3.1 Drained Conditions... 27 4.3.2 Undrained Conditions... 28 4.4 References... 30 4.5 Data Files... 30 5 Undrained Analysis of
Table of Contents 1 One Dimensional Compression of a Finite Layer... 3 1.1 Problem Description... 3 1.1.1 Uniform Mesh... 3 1.1.2 Graded Mesh... 5 1.2 Analytical Solution... 6 1.3 Results... 6 1.3.1 Uniform
ENCE 4610 Foundation Analysis and Design
This image cannot currently be displayed. ENCE 4610 Foundation Analysis and Design Shallow Foundations Total and Differential Settlement Schmertmann s Method This image cannot currently be displayed. Strength
A Theoretical Solution for Consolidation Rates of Stone Column-Reinforced Foundations Accounting for Smear and Well Resistance Effects
The International Journal of Geomechanics Volume, Number, 135 151 (00) A Theoretical Solution for Consolidation Rates of Stone Column-Reinforced Foundations Accounting for Smear and Well Resistance Effects
Strength Determination of "Tooth-Paste" Like Sand and Gravel Washing Fines Using DMT
Strength Determination of "Tooth-Paste" Like Sand and Gravel Washing Fines Using DMT David L. Knott, P.E. and James M. Sheahan, P.E. HDR Engineering, Inc. 3 Gateway Center Pittsburgh, PA 15222-1074 Phone:
How To Model A Shallow Foundation
Finite Element Analysis of Elastic Settlement of Spreadfootings Founded in Soil Jae H. Chung, Ph.D. Bid Bridge Software Institute t University of Florida, Gainesville, FL, USA Content 1. Background 2.
COSMOS 2012: Earthquakes in Action COSMOS 2012
COSMOS 2012 What is SFSI and why is it important? Soil issues in Earthquakes Structures where SFSI important Retaining structures (lateral earth pressure) Foundations (spread and pile footings, bearing
PREDICTING THE HYDRAULIC CONDUCTIVITY OF MAKASSAR MARINE CLAY USING FIELD PENETRATION TEST (CPTU) RESULTS
Proceedings of the Sixth International Conference on Asian and Pacific Coasts (APAC 2011) December 14 16, 2011, Hong Kong, China PREDICTING THE HYDRAULIC CONDUCTIVITY OF MAKASSAR MARINE CLAY USING FIELD
Figure A-1. Figure A-2. continued on next page... HPM-1. Grout Reservoir. Neat Cement Grout (Very Flowable) Extension Displacement Plate
Addendum HELICAL PULLDOWN Micropile (HPM) Introduction The HPM is a system for constructing a grout column around the shaft of a standard Helical Screw Foundation (see Figure A1). To begin the process,
Geotechnical Investigation using Standard Penetration Test (SPT) in Rangamati, Bandarban and Khagrachari Towns
1. Introduction 1.1 Scope of Work The Asian Disaster Preparedness Centre (ADPC) is implementing the project Seismic Hazard and Vulnerability Mapping for Rangamati, Bandarban and Khagrachari Municipality.
PART TWO GEOSYNTHETIC SOIL REINFORCEMENT. Martin Street Improvements, Fredonia, Wisconsin; Keystone Compac Hewnstone
GEOSYNTHETIC SOIL REINFORCEMENT Martin Street Improvements, Fredonia, Wisconsin; Keystone Compac Hewnstone DESIGN MANUAL & KEYWALL OPERATING GUIDE GEOSYNTHETIC SOIL REINFORCEMENT Keystone retaining walls
Compression load testing straw bale walls. Peter Walker Dept. Architecture & Civil Engineering University of Bath Bath BA2 7AY.
Compression load testing straw bale walls Peter Walker Dept. Architecture & Civil Engineering University of Bath Bath BA2 7AY May 2004 1. Introduction Over the last 10 years a growing number of loadbearing
Cone Penetration Testing in Geotechnical Practice. Tom Lunne Peter K. Robertson John J.M. Powell
Cone Penetration Testing in Geotechnical Practice Tom Lunne Peter K. Robertson John J.M. Powell BLACKIE ACADEMIC & PROFESSIONAL An Imprint of Chapman & Hall London Weinheim New York Tokyo Melbourne Madras
Applying a circular load. Immediate and consolidation settlement. Deformed contours. Query points and query lines. Graph query.
Quick Start Tutorial 1-1 Quick Start Tutorial This quick start tutorial will cover some of the basic features of Settle3D. A circular load is applied to a single soil layer and settlements are examined.
Geotechnical Investigation Test Report
Geotechnical Investigation Test Report Report No. htsc/rcd/ 3457 Dated: - 20/03/2010 Asphalt Standard Penetration Test as per IS 2131 ------------- IS 6403 Soil Job Card No - 1649 Cement Client/Department
NOTES on the CONE PENETROMETER TEST
GE 441 Advanced Engineering Geology & Geotechnics Spring 2004 Introduction NOTES on the CONE PENETROMETER TEST The standardized cone-penetrometer test (CPT) involves pushing a 1.41-inch diameter 55 o to
1 Mobilisation and demobilisation 1 Deep boring sum 2 Cone penetration tests sum 3 Miscellenous tests sum
Malaysian Civil Engineering Standard Method of Measurement (MyCESMM) CLASS D: SITE INVESTIGATION WORK Measurement covered under other classes: Excavation not carried out for the purpose of soil investigation
Settlement of Precast Culverts Under High Fills; The Influence of Construction Sequence and Structural Effects of Longitudinal Strains
Settlement of Precast Culverts Under High Fills; The Influence of Construction Sequence and Structural Effects of Longitudinal Strains Doug Jenkins 1, Chris Lawson 2 1 Interactive Design Services, 2 Reinforced
Estimation of Adjacent Building Settlement During Drilling of Urban Tunnels
Estimation of Adjacent Building During Drilling of Urban Tunnels Shahram Pourakbar 1, Mohammad Azadi 2, Bujang B. K. Huat 1, Afshin Asadi 1 1 Department of Civil Engineering, University Putra Malaysia
HYDRAULIC STRUCTURES, EQUIPMENT AND WATER DATA ACQUISITION SYSTEMS Vol. IV - Testing of Materials and Soils - F. Druyts
TESTING OF MATERIALS AND SOILS F. Druyts Pr. Eng., Department of Water Affairs and Forestry, Pretoria, South Africa Keywords: Materials testing, soil mechanics/properties, construction materials, earth
When to Use Immediate Settlement in Settle 3D
When to Use Immediate Settlement in Settle 3D Most engineers agree that settlement is made up of three components: immediate, primary consolidation and secondary consolidation (or creep). Most engineers
USE OF CONE PENETRATION TEST IN PILE DESIGN
PERIODICA POLYTECHNICA SER. CIV. ENG. VOL. 47, NO. 2, PP. 189 197 (23) USE OF CONE PENETRATION TEST IN PILE DESIGN András MAHLER Department of Geotechnics Budapest University of Technology and Economics
BEARING CAPACITY AND SETTLEMENT RESPONSE OF RAFT FOUNDATION ON SAND USING STANDARD PENETRATION TEST METHOD
SENRA Academic Publishers, British Columbia Vol., No. 1, pp. 27-2774, February 20 Online ISSN: 0-353; Print ISSN: 17-7 BEARING CAPACITY AND SETTLEMENT RESPONSE OF RAFT FOUNDATION ON SAND USING STANDARD
Local Authority Building Control Technical Information Note 3 Driven and In-situ Piled Foundations
Local Authority Building Control Technical Information Note 3 Driven and In-situ Piled Foundations Cambridge City Council - East Cambridgeshire District Council - Fenland District Council, Huntingdonshire
Miss S. S. Nibhorkar 1 1 M. E (Structure) Scholar,
Volume, Special Issue, ICSTSD Behaviour of Steel Bracing as a Global Retrofitting Technique Miss S. S. Nibhorkar M. E (Structure) Scholar, Civil Engineering Department, G. H. Raisoni College of Engineering
Mechanically stabilized layers in road construction
Mechanically stabilized layers in road construction Zikmund Rakowski, Jacek Kawalec Tensar International, UK, Technical University of Silesia, Poland Abstract: Effective and economical technologies are
Tests and Analyses on Shear Strength Increment of Soft Soil under Embankment Fill
Tests and Analyses on Shear Strength Increment of Soft Soil under Embankment Fill Guanbao Ye Professor Key Laboratory of Geotechnical and Underground Engineering,Tongji University, Ministry of Education,
INDIRECT METHODS SOUNDING OR PENETRATION TESTS. Dr. K. M. Kouzer, Associate Professor in Civil Engineering, GEC Kozhikode
INDIRECT METHODS SOUNDING OR PENETRATION TESTS STANDARD PENETRATION TEST (SPT) Reference can be made to IS 2131 1981 for details on SPT. It is a field edtest to estimate e the penetration e resistance
Investigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps
Foundations on Expansive Clay Soil Part 3 - Investigation of Failed Foundations Presented by: Eric Green, P.E. Structural Engineer Slide 1 Copyright Eric Green 2005 Investigation of Foundation Failure
DESIGNING STRUCTURES IN EXPANSIVE CLAY
DESIGNING STRUCTURES IN EXPANSIVE CLAY A GUIDE FOR A RCHITECTS AND E NGINEERS Table of Contents 1. Introduction Page 1 2. Common Foundation Systems Page 2 3. Drilled Piers Page 3 a. Skin Friction Piers
Soil Classification Through Penetration Tests
Pak. J. Engg. & Appl. Sci. Vol. 9, Jul., 2011 (p. 76-86) Soil Classification Through Penetration Tests A. H. Khan, A. Akbar, K. Farooq, N. M. Khan, M. Aziz and H. Mujtaba Department of Civil Engineering,
Soil Strength. Performance Evaluation of Constructed Facilities Fall 2004. Prof. Mesut Pervizpour Office: KH #203 Ph: x4046
ENGR-627 Performance Evaluation of Constructed Facilities, Lecture # 4 Performance Evaluation of Constructed Facilities Fall 2004 Prof. Mesut Pervizpour Office: KH #203 Ph: x4046 1 Soil Strength 2 Soil
Comparison of Seismic Retrofitting Methods for Existing Foundations in Seismological Active Regions
Comparison of Seismic Retrofitting Methods for Existing Foundations in Seismological Active Regions Peyman Amini Motlagh, Ali Pak Abstract Seismic retrofitting of important structures is essential in seismological
EXAMPLE 1 DESIGN OF CANTILEVERED WALL, GRANULAR SOIL
EXAMPLE DESIGN OF CANTILEVERED WALL, GRANULAR SOIL A sheet pile wall is required to support a 2 excavation. The soil is uniform as shown in the figure. To take into account the friction between the wall
CONCRETE SEGMENTAL RETAINING WALL SYSTEM
CONCRETE SEGMENTAL RETAINING WALL SYSTEM PART 1: GENERAL SPECIFICATIONS 1.01 Work Included A. Work shall consist of furnishing and constructing a Rockwood Classic 8 with PCS unit segmental retaining wall
A study on the causes of troubles in shield tunneling site with numerical analysis
A study on the causes of troubles in shield tunneling site with numerical analysis 1 B.K. Rho, 2 S.Y. Choo, 2 M.K. Song Korea Rail Network Authority, Daejeon, Korea 1 ; Danwoo E&C Co., Ltd., Sungnam, Korea
International Journal of Scientific & Engineering Research, Volume 4, Issue 9, September-2013 409 ISSN 2229-5518
International Journal of Scientific & Engineering Research, Volume 4, Issue 9, September-2013 409 Estimation of Undrained Shear Strength of Soil using Cone Penetration Test By Nwobasi, Paul Awo Department
SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)
SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701) 55-1 GENERAL The Contractor shall perform all work required by the plans for construction of pipe for storm drains, precast polymer trench drains
9.00 THE USE OF HUNTER LAND DRAINAGE PERFORATED PIPES. Hunter Underground Systems
9.00 THE USE OF HUNTER LAND DRAINAGE PERFORATED PIPES Hunter Underground Systems 9.01 General 9.02 Surface water Drainage 9.03 Groundwater Drainage 9.04 Dispersal of Septic Tank Effluent 9.01 The use of
CONCRETE SEGMENTAL RETAINING WALL SYSTEM
CONCRETE SEGMENTAL RETAINING WALL SYSTEM PART 1: GENERAL SPECIFICATIONS 1.01 Work Included A. Work shall consist of furnishing and constructing a Rockwood Vintage TM unit segmental retaining wall (SRW)
Estimation of Compression Properties of Clayey Soils Salt Lake Valley, Utah
Estimation of Compression Properties of Clayey Soils Salt Lake Valley, Utah Report Prepared for the Utah Department of Transportation Research Division by Steven F. Bartlett, PhD. P.E. Assistant Professor
Design, Testing and Automated Monitoring of ACIP Piles in Residual Soils
Design, Testing and Automated Monitoring of ACIP Piles in Residual Soils Stephen W. Lacz 1, M. ASCE, P.E. and Richard C. Wells 2, F. ASCE, P.E. 1 Senior Professional, Trigon Kleinfelder, Inc., 313 Gallimore
