ECN Engineering & Services Tools and Machinery List

Size: px
Start display at page:

Download "ECN Engineering & Services Tools and Machinery List"

Transcription

1 ECN Engineering & Services Tools and Machinery List

2 Tools and machinery list Manufacturing Brand/description Type Dimensions work piece [mm] CNC Turning Boehringer DUS 560 ti-2000 ø 520 x 2000 Montforts KNC-5 ø 450 x 1500 Montforts RNC-3 ø 180 x 500 Schaublin 125 CCN ø 200 x 450 Hwachon Hi Eco10 ø 200 x 500 CNC Milling Mikron VCE axis 1625 x 812 x 762 Mikron UCP axis 710 x 650 x 500 x 360º (-30º +120º) Mikron VCP x 400 x 350 Fehlmann PicoMax 54 3-axis 500 x 260 x 490 Cincinnati Milacron 760 x 510 x 500 Wire Cut Electro Discharge Machining Charmiles Robofil x 400 x 400 Sodick AQ 750 LH 750 x 600 x 600 Sodick AQ 300 L 300 x 200 x 200 Die-sinking Electro Discharge Machining Agie Agietron Innovation II 350 x 250 x 350 Grinding Studer S mm b.c.* and 100 mm c.h.** Studer S mm b.c. and 125 mm c.h. Jung JF520 MS NC 600 x 200 x 240 Jung JA600 CNC-E 600 x 250 x 240 Jung JP800 CNC A 800 x 500 x 500 max. 700 kg Moor jig grinder 450 CPR - CNC 458 x 280 x 350 mm Laser machining Baasel BLS610 (3x) YAG-marking/engraving laser 150 x 150, 200 x 200, 300 x 300 Lasag KLS YAG-cutting laser 1064nm 600 x 400 x 300 ( ) Lasag SLS 200C60 YAG-welding laser 1064nm, fiber 400 µm 600 x 400 x 300 Lasag SLS C YAG-welding laser 1064nm, fiber 100 µm 600 x 400 x 300 Rofin 20 E Diode pumped, 355nm 200x200 Quantronix Lamppumped and Q-switched 200x200 Geometrical control Mitutoyo Bright Strato 3D Measuring machine 1600 x 1000 x 600mm E=1,7+3L/1000 µm Talyrond 100 Roundness tester Mahr Perthometerconcept Contour meter Perthen PRK Pertometerconcept Rodenstock RM600-3D Roughness meter Optical roughness and contour meter * b.c. = between centers ** c.h. = center height

3 Brand/description Type Dimensions work piece [mm] Mitutoyo Laserscan micrometer ULM C Universal length measuring machine 600mm Mitutoyo Measuring microscope QV202 ApexPro x 200 x 150 Hewlett Packet Laser interferometer Pelt&Hooykaas Surface plate granite/ x 1250 Mahr Digimar DX1 Height gauge 600mm Zeiss Measuring microscope Heat treatments Vacuum or controlled atmosphere Hethrington oven Engineering Brand/description Type Application CoCreate One Space Modeler (7x) 3D CAD Database Management Model Manager PDM System ANSYS ANSYS Mechanical FEM AutoDesk Acad (5x) Vacuum: down to 10-5 bars Controlled atmosphere: Nitrogen, Hydrogen, Helium, Argon, Argon/ Hydrogen. Temperature: up to 1600 C (short time) Cold wall oven, suitable for hardening air hardening materials AutoDesk Acad P&ID (3x) MathSoft MathCad Modelling Norbert Schmitz SF Pressure Drop CODECALC PED Calculation ASME VIII MECID Eurofiler CE Process Systems Engineering Brand/description Type Application MathWorks Matlab, Simulink, Control System, Real Time Workshop, Simulink control, Stateflow, SF coder,xpc, xpc embedded, Matlab Optimization, Matlab PDE, Matlab Statistics System modelling general Aspen Tech Comsol In-house Aspen Plus, Aspen Dynamics, Aspen Custom Modeller, Aspen Icarus Multiphysics (voorheen Femlab), incl. Chemical Engineering Module, Control Script Cost-engineering models Materials Characterisation and Consultancy Brand/description Type Application Microscopy Field Emission Gun-Scanning Electron Microscope (FEG SEM) Simulation chemical engineering CFD, FEM, Reactor modelling JEOL 6330F Magnification up to x Lateral resolution (practical): 5nm High signal/noise ratio at 0.5keV, low electrical conductive materials can be analysed without pre-coating

4 Brand/description Type Application Element analyses by Energy Dispersive X-ray analyses Atomic Force Microscopy (AFM) Noran Vantage Nanoscope III Quantative Element analyses with an accuracy of ±0.5wt% starting at sodium (Na) Qualitative Element analyses down to Boor (B) Automated analyses and particle recognition Particles to be analysed can be down to 1µm 3 in size Full contact mode Horizontal and Lateral resolution down to 2nm Optical macroscope Wild M3Z Magnification up to X64 Optical microscope Leica MeF-4 Magnification up to X1500 Bright field Dark field Nomarski interference contrast Polarised light Image analyses and storage SIS Image storage Image analyses Coupled to optical macroscope and microscope Mechanical testing Tensile testing Comprision Instron 4501-series 9 Instron 4502-series 9 Instron 4505-series 9 Up to 100kN load Three and four point bending Room temperature (access to test load up to 2500kN) Rotating fatigue Wöhler machine Room temperature fatigue testing on standard test pieces. Testing of materials and coatings Hardness measurements Frank-Finotest Leica-Durimet Residual stress measurements Hole Drilling Macro-Vickers, up to 30kg load Brinell, 1mm ball up to 30kg Micro-Vickers, down to 0.05g Knoop hardness Brand/description Type Dimensions workpiece [mm] Preparation facilities Grinding Struers Knuth rotor 2 SiC grinding paper grit P150-P4000 Polishing Struers-Pedemax-2 6 samples at a time, maximum, different sizes possible Struers-PdM-Force 6 samples, standard size up to 25mm diameter Struers-Rotopol 3 + Rotoforce-4 6 samples, standard size up to 25mm diameter Embedding Struers embedding press 25mm samples Struers embedding press 12,5mm samples UV-hardening-Kulzer variable sample size Cold embedding masses Variable sample size, 24h curing at roomtemperature Cutting Struers Discotom-2 For cutting metallic, ceramic and plastic samples Struers Accutom 5 Precision cutting, µm precision

5 Brand/description Type Application Non-destructive analyses Non-destructive determination of E-module Determination of ferrite content Grindo Sonic Fischer Ferritescope-EN8D2-FE Fischer Ferritescope-MP3-GAB1.3 FED Homogeneous metalic and ceramic materials Room temperature Ferrite content up to 100% ferrite Can be modified for layer thickness measurements Materials Testing Brand/description Application Measurement ICP-AES (Spectro, Vista) Q Solid fuels, ash, sludge, biomass, water samples, eluates Al As B Ba Ca Cd Co Cr Cu Fe K Li Mg Mn Mo Na Ni P Pb S Sb Se Si Sn Sr Ti V Zn ICP-AES, (Spectro, Vista) Q Waste water Al As B Ba Ca Cd Co Cr Cu Fe K Li Mg Mn Mo Na Ni P Pb S Sb Se Si Sn Sr Ti V Zn ICP-AES, (Spectro, Vista) Q Catalysts, fuel cel components, solar cel On request products, nuclear products Hydride AFS Q Solid fuels, ash, sludge, biomass, water As Se Sb CV-AFS Q samples, eluates Hg Proximate Solid fossil fuels, solid biofuels, solid recovered Ash, moisture, volatile Caloric value Q fuels, sludges, biomass UHV LHV Biomass content by 14 C SRF, waste products, liquid fuels % Biogenic method Titrimetry Q Rainwater Alkalinity Membrane diffusion Rain water samples, eluates Ammonia Kjeldahl N Fotometry Q (Dr. Lange) Water samples, eluates, samples from COD Ionchromatography (Dionex, Metrohm) gasifiers Cl NO 3 SO 4 Br Q Flow Injection Analysis Element analyser (Interscience) Q Titrimetry (Metrohm) Fossil fuels, biofuels, solid recovered fuelsorganic compounds Fuel cell components, catalysts, nuclear products F, CN C H N O High precision element determination EOX analyser, coulometry Q Waste water Non-volatile halogen compounds Coulometry Q Solid fuels Halogen content (Cl Br I) TOC analyser (Shimadzu) Waste water Organic and inorganic carbon HPLC (DAD FLD) (Agilent) Air, soil, water 16 PAH EPA GC-FID (GC-MS) (Shimadzu, Interscience) Q Tar extracts 16 PAH EPA and 19 other common tar compounds Micro-GC NDIR spectroscopy Chemolumniscence Physical characterisation Partical size analyses Partical size analyses Autosizer + multipurpose tritator Pore size analyses Mercury method Syngas, biogas, emission, proces gas Malvern Instruments Mastersizer 2000 Malvern Instruments Nanosizer ZEN 3600 Micrometeritics-Autopore II Up to 150µm H 2 N 2 O 2 CO CO 2 CH 4 H 2 S COS CO CO 2 CH 4 N 2 O NOx Particle sizes 20nm to 2mm Static light scattering Q. = ISO approved

6 Brand/description Application Measurement Pore size analyses-gas Coulter Omnisorb Down to 0.3nm absorption Determination of specific surface area Dilatometry (thermal expension coefficient determination) Simultaneous Thermal Analyses (STA Differential Scanning Calorimetry (DSC) + Automatic Sample Changer BET-Sorbty 1750 Coulter Omnisorb Netzsch-DIL402 C/4/G Temperature: up to 1650 C Atmospheres: standard: air, helium, Ar/5%H 2, oxygen. Other atmospheres on request. Rate Controlled Sintering software Accuracy: 1.25nm over 25mm measuring length Netzsch STA 409 PC LUXX Netzsch DSC 204 F1 Phoenix Software & Electrical Engineering Brand/description Type Application Compilers Microsoft Visual Studio 2008,.NET C# DTA/TG (Differential Thermal Analyses/Thermographimetry) up to 1550 C Atmospheres: standard: air, helium, Ar/5%H 2, oxygen, former gasses DSC (Differential Scanning Calorimetry) Temp range: -180 C to 700 C Heating/Cooling rates: to 100 K/min Microsoft Microsoft Borland Visual Studio 2008, C Windows CE V5.0, C++ Delphi GNU gcc Libraries ComponentOne ComponentOne Studio ASP.NET Charts/graphs Microsoft WCF WPF Web development Apache Apache 2.0/54 PHP TYPO3 TYPO3 Content Management System Databases Microsoft SQL-server MySQL AB MySQL PostgreSQL PostgreSQL Proces control development Exeda Wizcon SCADA Process control National Instruments 1) Labview 2) Compact Rio Data-acquisition & control Beckhoff TwinCat SoftPLC Process control Embedded system tools Echelon Nodebuilder C/Neuron C MicroChip PIC processors C Keil GMBH Intel 8051-series C Microsoft Embedded XP C, C#, ASP.NET

7 Brand/description Type Application Microsoft Platform Builder Windows CE Altera FPGA s VHDL/schematic design Modelling MathWorks Matlab, Simulink Aspen Embedded codex Embedded systems Documentation Adobe Adobe Photoshop + Premiere Acrobat GNU gimp L A T E X 2å Power Quality Measurement Wideband Current Probes + Amplifier 3x Differential Probes Image manipulation Desktop publishing Harmonic analyser PM 300 Voltech Residual mains / grid utility Power monitor Nanovip Distribution stations & cabinets A. Power and Energy datalogger MFT 300 Distribution cabinets Up to 12 fields yielding 100A. Memory oscilloscoop Tektronix TDS 3014 Tektronix 2221A Tektronix 2225 Instrumentation Calibration of field instruments Trending & signal monitoring Insulation testing Inspection & test of electric equipment acc. to NEN 3140 Tektronix AM503B Tektronix A6302 Tektronix A6303 Tektronix P5200 Burster signal conversion generator/ calibrator Digistant 4421 Knick Voltage source Knick Voltage reference Hydra datalogger 2620A Hewlett Packard 34970A Datalogger & Software PAD tester Nieaff Smitt DC Bushbars Power convertors Rectifiers Power transformers Grid coupled 3-phase measurements Transducers: flow, pressure, force, temperature, humidity, conductivity, volts, amps, power etc. Transducer outputs Electric tools: household & industrial according to NEN-EN 3140 Earth & circuit tester Combitester Gossen M5020 Grid utility & experimental applications Power performance tests Power source/sinking Digatron EVT DUT 350A bidirectional Power source/sinking Digatron EVT DUT 400A bidirectional Power supply Delta SMD DUT 100A unidirectional Power supply Delta SMD DUT 10A unidirectional Power supply Delta SMD DUT 20A unidirectional Power supply Delta SMD 120-4x25 (3)slaves DUT 100A unidirectional Power supply Delta E L DUT 0,1A unidirectional Computer & Communication Testing CPU and periferie testing Logic analyser Computer equipment

8 Brand/description Type Application Testing physical link layer Data analyser Communications, protocol Serial data Hardware Sweep generator Hewlett Packard 2849-G07566 Laboratory test: EUT & DUT Scope Hewlett Packard 54645D Idem Tektronix TDS3032 Digital Multimeter Fluke 87 III, Keithley , 2000, 2700, Idem 7700 Frequency counter Hewlett Packard 3416A, 53131A (1Ghz) Arbritary Waveform Generator Hewlett Packard 33120A Calibrator Burster Digistant 4420 Currentprobe Data Aquisition/Switch Electronic load Chauvin Arnoug E3n Tektronix A6302, A6303 Agilent/HP 34970A Hocherl & Hackl PL306, PL306A Climate Chamber Clive Hurley CH Espec PL3-KPH Espec TSD-100 LISN Netsimulator Binder MK720 Thurlby Thandar 1phase 16 amp Schwarzbeck, NSLK 8128 Spitzenberger & Spies 1 phase 5000W Power analyzer Norma D6000 Norma D6100 Yokogawa PZ4000 Yokogawa WT110 Voltech PM300 Power supply Delta SM D, SM D, SM D, SM 7020-D, 1200 S 48 Agilent/HP 6642A, E4350A, E4350B, Kepco BOP 36-6M, BOP 100-4M -40 C to 180 C, 20% - 98% RH, 1687 ltr -40 C to 150 C, 20% - 98% RH, 408 ltr -65 C to 0 C and 60 C to 200 C, no RH, 100 ltr, 30 kg -40 C to 180 C, no RH, 700 ltr EMC Line impedance Three phase, Harm analysis Three phase Three phase, Harm analysis Single phase Three phase Current, SAS and bipolair EMC Teseq NSG 3040 EMC Test system Teseq NSG 437 ESD Simulator EMTEST VCS500 Surge generator Advantest R3261A Spectrum analyser 9kHz to 2.6GHz Advantest TR Search coil FCC F-33-2 RF current probe 1kHZ to 250 MHz Schaffner CDN 8014 Capacitive Coupling Clamp Energieonderzoek Centrum Nederland Engineering & Services Postbus 1, 1755 ZG Petten Tel.: Fax: es@ecn.nl b

Espotel Test Laboratory Services. November 20, 2014

Espotel Test Laboratory Services. November 20, 2014 Espotel Test Laboratory Services November 20, 2014 Espotel Laboratory Services EMC, ESD, RF testing EMC chamber for radiated emissions and immunity testing Radiated interoperability for LTE, GSM/3G, WLAN

More information

Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Solid State Energy Meter

Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Solid State Energy Meter Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Model: Solid State Energy Meter Prepared for: Analog Devices, Inc. 804 Woburn Street Wilmington, MA 01887 Date of

More information

h e l p s y o u C O N T R O L

h e l p s y o u C O N T R O L contamination analysis for compound semiconductors ANALYTICAL SERVICES B u r i e d d e f e c t s, E v a n s A n a l y t i c a l g r o u p h e l p s y o u C O N T R O L C O N T A M I N A T I O N Contamination

More information

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02

More information

Multi-elemental determination of gasoline using Agilent 5100 ICP-OES with oxygen injection and a temperature controlled spray chamber

Multi-elemental determination of gasoline using Agilent 5100 ICP-OES with oxygen injection and a temperature controlled spray chamber Multi-elemental determination of gasoline using Agilent 5100 ICP-OES with oxygen injection and a temperature controlled spray chamber Application note Energy & chemicals, petrochemicals Authors Elizabeth

More information

EXPERIMENT 4 The Periodic Table - Atoms and Elements

EXPERIMENT 4 The Periodic Table - Atoms and Elements EXPERIMENT 4 The Periodic Table - Atoms and Elements INTRODUCTION Primary substances, called elements, build all the materials around you. There are more than 109 different elements known today. The elements

More information

Sampling and preparation of heterogeneous waste fuels?

Sampling and preparation of heterogeneous waste fuels? Sampling and preparation of heterogeneous waste fuels? Is it possible to accomplish a representative and relevant composition data? Evalena Wikström, Lennart Gustavsson and Jolanta Franke Aim of the project

More information

Material data sheet. EOS Aluminium AlSi10Mg. Description

Material data sheet. EOS Aluminium AlSi10Mg. Description EOS Aluminium AlSi10Mg EOS Aluminium AlSi10Mg is an aluminium alloy in fine powder form which has been specially optimised for processing on EOSINT M systems This document provides information and data

More information

The laboratory fulfils the requirements for periodic emission measurement according to ČSN P CEN/TS 15675:2009

The laboratory fulfils the requirements for periodic emission measurement according to ČSN P CEN/TS 15675:2009 Page 1 of 8 Testing laboratory working site: Working place 1: Technické služby ochrany ovzduší Praha a.s. Testing Laboratory for Measuring Pollutants, Jenečská 146/44, 161 00 Praha Working place 3: Organizational

More information

Analyses on copper samples from Micans

Analyses on copper samples from Micans PDF rendering: DokumentID 1473479, Version 1., Status Godkänt, Sekretessklass Öppen Analyses on copper samples from Micans P. Berastegui, M. Hahlin, M. Ottosson, M. Korvela, Y. Andersson, R. Berger and

More information

Maschinenliste. FB 630-302 Version 04 Seite 1 von 5. CAD Construction / data management

Maschinenliste. FB 630-302 Version 04 Seite 1 von 5. CAD Construction / data management Seite 1 von 5 CAD Construction / data management Solidworks Professional Solid Works Enterprise PDM Trans Magic Pro R10 CAM - Programming Surfcam Advanced 2A +5A 2D & 3D as well as simultaneous machining

More information

Material data sheet. EOS Aluminium AlSi10Mg_200C. Description

Material data sheet. EOS Aluminium AlSi10Mg_200C. Description EOS Aluminium AlSi10Mg_200C All information in this data sheet refers to the alloy EOS Aluminium AlSi10Mg_200C. This alloy is formed when the powder EOS Aluminium AlSi10Mg is processes at a building platform

More information

Material and methods. Värmeforsk report 1212 2012 Niklas Hansson DIANAS utilization of waste inciniration bottom ash in bound construction materials

Material and methods. Värmeforsk report 1212 2012 Niklas Hansson DIANAS utilization of waste inciniration bottom ash in bound construction materials Värmeforsk report 1212 2012 Niklas Hansson DIANAS utilization of waste inciniration bottom ash in bound construction materials Executive Summary Introduction In an international perspective waste incineration

More information

Methods for the preparation of the test sample from the laboratory sample (Part 1 Material & Methods) Work Package 6 Task 6.4

Methods for the preparation of the test sample from the laboratory sample (Part 1 Material & Methods) Work Package 6 Task 6.4 Methods for the preparation of the test sample from the laboratory sample (Part 1 Material & Methods) Work Package 6 Task 6.4 Validation of prcen/ts 15413 (WI 343027) Paolo de Zorzi APAT - Italian Environmental

More information

CLASS TEST GRADE 11. PHYSICAL SCIENCES: CHEMISTRY Test 6: Chemical change

CLASS TEST GRADE 11. PHYSICAL SCIENCES: CHEMISTRY Test 6: Chemical change CLASS TEST GRADE PHYSICAL SCIENCES: CHEMISTRY Test 6: Chemical change MARKS: 45 TIME: hour INSTRUCTIONS AND INFORMATION. Answer ALL the questions. 2. You may use non-programmable calculators. 3. You may

More information

Chem 115 POGIL Worksheet - Week 4 Moles & Stoichiometry

Chem 115 POGIL Worksheet - Week 4 Moles & Stoichiometry Chem 115 POGIL Worksheet - Week 4 Moles & Stoichiometry Why? Chemists are concerned with mass relationships in chemical reactions, usually run on a macroscopic scale (grams, kilograms, etc.). To deal with

More information

ATI Wah Chang Laboratory and Technical Services: Analytical Laboratory

ATI Wah Chang Laboratory and Technical Services: Analytical Laboratory ATI Wah Chang Laboratory and Technical Services: Analytical Laboratory TECHNICAL DATA SHEET INTRODUCTION For over 50 years, ATI Wah Chang s laboratory personnel have been producing high quality inorganic

More information

47374_04_p25-32.qxd 2/9/07 7:50 AM Page 25. 4 Atoms and Elements

47374_04_p25-32.qxd 2/9/07 7:50 AM Page 25. 4 Atoms and Elements 47374_04_p25-32.qxd 2/9/07 7:50 AM Page 25 4 Atoms and Elements 4.1 a. Cu b. Si c. K d. N e. Fe f. Ba g. Pb h. Sr 4.2 a. O b. Li c. S d. Al e. H f. Ne g. Sn h. Au 4.3 a. carbon b. chlorine c. iodine d.

More information

SCS Directory Accreditation number: SCS 0115

SCS Directory Accreditation number: SCS 0115 International standard: ISO/IEC 17025:2005 Swiss standard: SN EN ISO/IEC 17025:2005 METRON SA Calibration Laboratory Via Luserte Sud 7 CH-6572 Quartino Head: Angelo Capone Responsible for MS: Angelo Capone

More information

Coating Thickness and Composition Analysis by Micro-EDXRF

Coating Thickness and Composition Analysis by Micro-EDXRF Application Note: XRF Coating Thickness and Composition Analysis by Micro-EDXRF www.edax.com Coating Thickness and Composition Analysis by Micro-EDXRF Introduction: The use of coatings in the modern manufacturing

More information

Test Report #: 1981-3 Date: April 8, 2005

Test Report #: 1981-3 Date: April 8, 2005 Test Report #: 1981-3 Date: April 8, 2005 CERTIFICATE #2316.01 Issued To: Bill Burks American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description Model

More information

North American Stainless Long Products

North American Stainless Long Products North American Stainless Long Products 1 North American Stainless North American Stainless is part of the most competitive stainless steel manufacturing group in the world, Acerinox, S.A. The development

More information

Flow Injection Analysis

Flow Injection Analysis Flow Injection Analysis Almost all reagent based assays can be downscaled and automated by Flow Injection Analysis. FIA was first described in a patent filed in Denmark by Ruzicka and Hansen in 1974. Since

More information

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 EN 301 489-17 v1.2.1 TEST REPORT FOR 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 ISSUE DATE: JANUARY 29, 2008 Prepared for BROADCOM CORPORATION 190 MATHILDA

More information

Chem 115 POGIL Worksheet - Week 4 Moles & Stoichiometry Answers

Chem 115 POGIL Worksheet - Week 4 Moles & Stoichiometry Answers Key Questions & Exercises Chem 115 POGIL Worksheet - Week 4 Moles & Stoichiometry Answers 1. The atomic weight of carbon is 12.0107 u, so a mole of carbon has a mass of 12.0107 g. Why doesn t a mole of

More information

Laser beam sintering of coatings and structures

Laser beam sintering of coatings and structures Laser beam sintering of coatings and structures Anne- Maria Reinecke, Peter Regenfuß, Maren Nieher, Sascha Klötzer, Robby Ebert, Horst Exner Laserinstitut Mittelsachsen e.v. an der Hochschule Mittweida,

More information

Analytical Testing Services Commercial Price List ManTech International Corporation January 2016

Analytical Testing Services Commercial Price List ManTech International Corporation January 2016 Analytical ing Services Commercial List ManTech International Corporation January 2016 TABLE OF CONTENTS MECHANICAL TENSILE TESTING... 1 DIFFERENTIAL SCANNING CALORIMETRY (DSC)... 2 THERMOMECHANICAL ANALYSIS

More information

Electron Microscopy 3. SEM. Image formation, detection, resolution, signal to noise ratio, interaction volume, contrasts

Electron Microscopy 3. SEM. Image formation, detection, resolution, signal to noise ratio, interaction volume, contrasts Electron Microscopy 3. SEM Image formation, detection, resolution, signal to noise ratio, interaction volume, contrasts 3-1 SEM is easy! Just focus and shoot "Photo"!!! Please comment this picture... Any

More information

CHP Plant based on a Hybrid Biomass and Solar System of the Next Generation EU project No. ENER/FP7/249800/"SUNSTORE 4" Dipl.-Ing. Alfred Hammerschmid

CHP Plant based on a Hybrid Biomass and Solar System of the Next Generation EU project No. ENER/FP7/249800/SUNSTORE 4 Dipl.-Ing. Alfred Hammerschmid CHP Plant based on a Hybrid Biomass and Solar System of the Next Generation EU project No. ENER/FP7/249800/"SUNSTORE 4" Dipl.-Ing. Alfred Hammerschmid BIOS BIOENERGIESYSTEME GmbH, Austria TEL.: +43 (316)

More information

Periodic Table Questions

Periodic Table Questions Periodic Table Questions 1. The elements characterized as nonmetals are located in the periodic table at the (1) far left; (2) bottom; (3) center; (4) top right. 2. An element that is a liquid at STP is

More information

Pore size and BET surface area. analysis at your fingertips. SA 3100. Gas Adsorption Analyzer

Pore size and BET surface area. analysis at your fingertips. SA 3100. Gas Adsorption Analyzer Pore size and BET surface area analysis at your fingertips. SA 3100 Gas Adsorption Analyzer The History of Beckman Coulter Particle Characterization Introducing The SA 3100 Surface Area and Pore Size Analyzer

More information

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection w Technical Product Information Precision Miniature Load Cell with Overload Protection 1. Introduction The load cells in the model 8431 and 8432 series are primarily designed for the measurement of force

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK code Location code Customers Sites locations: 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK Calibration Centre Bolkiah Garrison BB3510 Negara Brunei Darussalam Contact: Mr Lim Tiong Thai Tel: +673-2-386475

More information

CVD SILICON CARBIDE. CVD SILICON CARBIDE s attributes include:

CVD SILICON CARBIDE. CVD SILICON CARBIDE s attributes include: CVD SILICON CARBIDE CVD SILICON CARBIDE is the ideal performance material for design engineers. It outperforms conventional forms of silicon carbide, as well as other ceramics, quartz, and metals in chemical

More information

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820 Test Report Prepared for: Technologic Systems, Inc. Model: TS-8820 Description: Single Board Computer with Analog and Digital Inputs and Outputs, Relays, and RS-232/485 Ports To IEC 61000-6-1 (2005-03)

More information

3. What would you predict for the intensity and binding energy for the 3p orbital for that of sulfur?

3. What would you predict for the intensity and binding energy for the 3p orbital for that of sulfur? PSI AP Chemistry Periodic Trends MC Review Name Periodic Law and the Quantum Model Use the PES spectrum of Phosphorus below to answer questions 1-3. 1. Which peak corresponds to the 1s orbital? (A) 1.06

More information

A.P.I.C.E. Common Mediterranean strategy and local practical Actions for the mitigation of Port, Industries and Cities Emissions

A.P.I.C.E. Common Mediterranean strategy and local practical Actions for the mitigation of Port, Industries and Cities Emissions A.P.I.C.E. Common Mediterranean strategy and local practical Actions for the mitigation of Port, Industries and Cities Emissions WP4: Air monitoring and receptor models Kick off meeting Marseille, 8 th

More information

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049

More information

Material data sheet. EOS CobaltChrome MP1. Description

Material data sheet. EOS CobaltChrome MP1. Description EOS CobaltChrome MP1 EOS CobaltChrome MP1 is a cobalt-chrome-molybdenum-based superalloy powder which has been optimized especially for processing on EOSINT M systems. This document provides information

More information

APPLICATION OF X-RAY COMPUTED TOMOGRAPHY IN SILICON SOLAR CELLS

APPLICATION OF X-RAY COMPUTED TOMOGRAPHY IN SILICON SOLAR CELLS APPLICATION OF X-RAY COMPUTED TOMOGRAPHY IN SILICON SOLAR CELLS V.A. Popovich 1, W. Verwaal 2, M. Janssen 1, I. J. Bennett 3, I.M.Richardson 1, 1. Delft University of Technology, Department of Materials

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

digital quality control fail pass at your fingertips Smart Metrology Solutions.

digital quality control fail pass at your fingertips Smart Metrology Solutions. digital quality control fail pass µphase smartgage The clever innovation in digital metrology by FISBA, which lets you smarten up your quality management and economize your production processes, yet spares

More information

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES) Features: DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES) PATENT NUMBERS: CANADA 2,494,133, USA 7095931, 7295731 AND CHINA 1672073 Telcordia GR-468 qualified Available in versions for any wavelength

More information

Short overview of TEUFEL-project

Short overview of TEUFEL-project Short overview of TEUFEL-project ELAN-meeting may 2004 Frascati (I) Contents Overview of TEUFEL project at Twente Photo cathode research Recent experience Outlook Overview FEL Drive laser Photo cathode

More information

All answers must use the correct number of significant figures, and must show units!

All answers must use the correct number of significant figures, and must show units! CHEM 10113, Quiz 2 September 7, 2011 Name (please print) All answers must use the correct number of significant figures, and must show units! IA Periodic Table of the Elements VIIIA (1) (18) 1 2 1 H IIA

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

Calibration. How can you get lower costs for the calibration? What is traceability? What is measurement uncertainty? What is calibration?

Calibration. How can you get lower costs for the calibration? What is traceability? What is measurement uncertainty? What is calibration? Calibration Tvinnargatan 25 SE-507 30 Brämhult SWEDEN Phone: +46 33 22 56 30 Fax: +46 33 13 88 71 info@kalibrera.se www.kalibrera.se In May 2011 Elastocon purchased the company Mätcentrum in Eskilstuna,

More information

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method G8 GALILEO High-End Melt-extraction Analyzer Innovation with Integrity Inert Gas Method Determination of O, N and H The market demands Metals, minerals, and inorganic compound markets demand high-quality

More information

Cond-IS RF Conducted Immunity System

Cond-IS RF Conducted Immunity System Cond-IS RF Conducted Immunity System About RF Conducted Immunity In the global contest of EMC testing for residential and industrial EUTs (Equipments Under Test) RF Conducted Immunity compliance verification

More information

Chapter 8 - Chemical Equations and Reactions

Chapter 8 - Chemical Equations and Reactions Chapter 8 - Chemical Equations and Reactions 8-1 Describing Chemical Reactions I. Introduction A. Reactants 1. Original substances entering into a chemical rxn B. Products 1. The resulting substances from

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

Lab facilities for School of Architecture and Built Environment

Lab facilities for School of Architecture and Built Environment Lab facilities for School of Architecture and Built Environment Laboratories 1. Engineering Graphics Lab 2. Surveying Lab 3. Material Testing Lab 4. Fluid Mechanics Lab 5. Concrete Lab 6. Environment Engineering

More information

Material data sheet. EOS StainlessSteel GP1 for EOSINT M 270. Description, application

Material data sheet. EOS StainlessSteel GP1 for EOSINT M 270. Description, application EOS StainlessSteel GP1 for EOSINT M 270 A number of different materials are available for use with EOSINT M systems, offering a broad range of e-manufacturing applications. EOS StainlessSteel GP1 is a

More information

ngenieros Ingenieros Asociados De Control S.L.

ngenieros Ingenieros Asociados De Control S.L. ngenieros sociados de ontrol 1 Company founded in 1985 to serve commercial and technical assistance in the fields of instrumentation, control and installation for all types of industries. We offer top

More information

R=Required by Lab S=May be subcontracted IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES

R=Required by Lab S=May be subcontracted IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES IEC SYSTEM FO CONFOMITY TESTING AND CETIFICATION OF ELECTICAL EQUIPMENT COMMITTEE OF TESTING LABOATOIES TESTING AND MEASUING EQUIPMENT/ALLOWED SUBCONTACTING Power cables with extruded insulation and their

More information

PROMPT ENGINEERING & TRADING SERVICES CO. W.L.L P.O. BOX 24067 BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR

PROMPT ENGINEERING & TRADING SERVICES CO. W.L.L P.O. BOX 24067 BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR This is to signify that PROMPT ENGINEERING & TRADING SERVICES CO. W.L.L P.O. BOX 24067 BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR Calibration Laboratory CL-165 has met the requirements

More information

Modification of Pd-H 2 and Pd-D 2 thin films processed by He-Ne laser

Modification of Pd-H 2 and Pd-D 2 thin films processed by He-Ne laser Modification of Pd-H 2 and Pd-D 2 thin films processed by He-Ne laser V.Nassisi #, G.Caretto #, A. Lorusso #, D.Manno %, L.Famà %, G.Buccolieri %, A.Buccolieri %, U.Mastromatteo* # Laboratory of Applied

More information

Chem 1A Exam 2 Review Problems

Chem 1A Exam 2 Review Problems Chem 1A Exam 2 Review Problems 1. At 0.967 atm, the height of mercury in a barometer is 0.735 m. If the mercury were replaced with water, what height of water (in meters) would be supported at this pressure?

More information

Subminiature Load Cell Model 8417

Subminiature Load Cell Model 8417 w Technical Product Information Subminiature Load Cell 1. Introduction... 2 2. Preparing for use... 2 2.1 Unpacking... 2 2.2 Using the instrument for the first time... 2 2.3 Grounding and potential connection...

More information

Testing and characterization of anti-reflection coatings on glass

Testing and characterization of anti-reflection coatings on glass Testing and characterization of anti-reflection coatings on glass Diagnostic approaches at CSP M.Turek, M. Dyrba, S. Großer, V. Naumann, Ch. Hagendorf contact: marko.turek@csp.fraunhofer.de Tests and methods

More information

B) atomic number C) both the solid and the liquid phase D) Au C) Sn, Si, C A) metal C) O, S, Se C) In D) tin D) methane D) bismuth B) Group 2 metal

B) atomic number C) both the solid and the liquid phase D) Au C) Sn, Si, C A) metal C) O, S, Se C) In D) tin D) methane D) bismuth B) Group 2 metal 1. The elements on the Periodic Table are arranged in order of increasing A) atomic mass B) atomic number C) molar mass D) oxidation number 2. Which list of elements consists of a metal, a metalloid, and

More information

Fast Z-stacking 3D Microscopy Extended Depth of Field Autofocus Z Depth Measurement 3D Surface Analysis

Fast Z-stacking 3D Microscopy Extended Depth of Field Autofocus Z Depth Measurement 3D Surface Analysis Cam CANIMPEX CPX-SOLUTIONS 3D Digital Microscope Camera FAST PRECISE AFFORDABLE 3D CAMERA FOR MICROSCOPY Fast Z-stacking 3D Microscopy Extended Depth of Field Autofocus Z Depth Measurement 3D Surface Analysis

More information

Material data sheet. EOS MaragingSteel MS1. Description

Material data sheet. EOS MaragingSteel MS1. Description EOS MaragingSteel MS1 EOS MaragingSteel MS1 is a steel powder which has been optimized especially for processing on EOSINT M systems. This document provides information and data for parts built using EOS

More information

Preface Light Microscopy X-ray Diffraction Methods

Preface Light Microscopy X-ray Diffraction Methods Preface xi 1 Light Microscopy 1 1.1 Optical Principles 1 1.1.1 Image Formation 1 1.1.2 Resolution 3 1.1.3 Depth of Field 5 1.1.4 Aberrations 6 1.2 Instrumentation 8 1.2.1 Illumination System 9 1.2.2 Objective

More information

MILESTONE H E L P I N G C H E M I S T S

MILESTONE H E L P I N G C H E M I S T S MILESTONE H E L P I N G C H E M I S T S 8 good reasons to choose the Milestone DMA-80 1. No sample preparation The DMA-80 does not require any sample preparation or other wet chemistry prior the analysis.

More information

Rapid Prototyping Technologies. May, 2016

Rapid Prototyping Technologies. May, 2016 Rapid Prototyping Technologies May, 2016 WE HAVE ALL THE NECESSARY TOOLS TO ENSURE THE FINAL SUCCESS OF YOUR PROTOTYPE. Andaltec can help you in all the steps, from the design to fully finished prototype

More information

Elemental analyzer multi EA 5000

Elemental analyzer multi EA 5000 Elemental analyzer multi EA 5000 Analytik Jena AG Konrad-Zuse-Str. 1 07745 Jena/Germany www.analytik-jena.com info@analytik-jena.com 1/6 multi EA 5000 The multi EA 5000 is a powerful elemental analyzer

More information

UNIT (2) ATOMS AND ELEMENTS

UNIT (2) ATOMS AND ELEMENTS UNIT (2) ATOMS AND ELEMENTS 2.1 Elements An element is a fundamental substance that cannot be broken down by chemical means into simpler substances. Each element is represented by an abbreviation called

More information

Automotive Electronics Council Component Technical Committee

Automotive Electronics Council Component Technical Committee AEC - Q101-005 - REV- ATTACHMENT 5 AEC - Q101-005 Rev- CAPACITIVE DISCHARGE MODEL (CDM) ELECTROSTATIC DISCHARGE (ESD) TEST METHOD - 005 DISCRETE COMPONENT CHARGED DEVICE MODEL (CDM) ELECTROSTATIC DISCHARGE

More information

CALL FOR OFFER. Győr Distillery Co. Ltd. (H-9027 Győr, Budai u. 7.) hereinafter referred to as Investor calls for offers in subject matter below

CALL FOR OFFER. Győr Distillery Co. Ltd. (H-9027 Győr, Budai u. 7.) hereinafter referred to as Investor calls for offers in subject matter below CALL FOR OFFER Győr Distillery Co. Ltd. (H-9027 Győr, Budai u. 7.) hereinafter referred to as Investor calls for offers in subject matter below Investor: Győr Distillery Co. Ltd. 9027 Győr, Budai u. 7.

More information

testing equipment for quality management Programme summary. METROLOGY Tensile and Pressure Testing Machines Measuring Devices Display Devices

testing equipment for quality management Programme summary. METROLOGY Tensile and Pressure Testing Machines Measuring Devices Display Devices testing equipment for quality management Programme summary. METROLOGY Sheet metal testing Surface testing Corrosion testing Tensile and Pressure Testing Machines Measuring Devices Display Devices The physical

More information

SUS. Company Profile. Ulrich Nell, Feldstr.23, D - 46149 Oberhausen, Tel. 0049(0)208/658535 Fax 0049(0)208/658536

SUS. Company Profile. Ulrich Nell, Feldstr.23, D - 46149 Oberhausen, Tel. 0049(0)208/658535 Fax 0049(0)208/658536 SUS Ulrich Nell, Feldstr.23, D - 46149 Oberhausen, Tel. 0049(0208/658535 Fax 0049(0208/658536 Company Profile SUS was founded in 1986 in Oberhausen in the Ruhr area (close to Düsseldorf, in order to meet

More information

CHAPTER-3: EXPERIMENTAL PROCEDURE

CHAPTER-3: EXPERIMENTAL PROCEDURE CHAPTER-3: EXPERIMENTAL PROCEDURE 58 3. EXPERIMENTAL PROCEDURE This chapter presents the experimental set up used to carryout characterization of the samples, granulometry studies and pellet firing studies.

More information

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module Engineering Test Report No. 37802-02 Rev. A Measurement of RF Emissions from a Final Coat Electronics Corrosion Module For : Canadian Auto Preservation, Inc. 390 Bradwick Drive Concord, Ontario CANADA

More information

Find a pair of elements in the periodic table with atomic numbers less than 20 that are an exception to the original periodic law.

Find a pair of elements in the periodic table with atomic numbers less than 20 that are an exception to the original periodic law. Example Exercise 6.1 Periodic Law Find the two elements in the fifth row of the periodic table that violate the original periodic law proposed by Mendeleev. Mendeleev proposed that elements be arranged

More information

From Quantum to Matter 2006

From Quantum to Matter 2006 From Quantum to Matter 006 Why such a course? Ronald Griessen Vrije Universiteit, Amsterdam AMOLF, May 4, 004 vrije Universiteit amsterdam Why study quantum mechanics? From Quantum to Matter: The main

More information

PIPELINE LEAKAGE DETECTION USING FIBER-OPTIC DISTRIBUTED STRAIN AND TEMPERATURE SENSORS WHITE PAPER

PIPELINE LEAKAGE DETECTION USING FIBER-OPTIC DISTRIBUTED STRAIN AND TEMPERATURE SENSORS WHITE PAPER PIPELINE LEAKAGE DETECTION USING FIBER-OPTIC DISTRIBUTED STRAIN AND TEMPERATURE SENSORS WHITE PAPER Lufan Zou and Taha Landolsi OZ Optics Limited, 219 Westbrook Road, Ottawa, ON, Canada, K0A 1L0 E-mail:

More information

Injection moulding and modelling on a micro scale

Injection moulding and modelling on a micro scale Injection moulding and modelling on a micro scale Technology Update Injection moulding and welding of plastics 11 November 2014 Research Projects (National / European) Micro/Nano/Multimaterial Manufacturing

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: PTZ CAMERA SAMSUNG SCP2371HP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

Unmatched Metal Hardness Testing

Unmatched Metal Hardness Testing Unmatched Metal Hardness Testing The Equostat 3 hardness tester can be connected both to the portable Equotip 3 platform and directly to a PC, with graphic user guidance Hardness Measurements made easy

More information

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) DESCRIPTION The Radar Level Meters of BM COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement. The microwave impulses, emitted

More information

The L&J Engineering Model MCG 1500SFI Servo Gauge

The L&J Engineering Model MCG 1500SFI Servo Gauge PRODUCT DATA SHEET The is the most compact and lightest servo available today. Accuracy / repeatability of 1/32 inch (0.8mm) Product and Interface, custody transfer Wireless Infrared Calibration Advanced

More information

COMBIMASS. Technical Data COMBIMASS eco-bio +

COMBIMASS. Technical Data COMBIMASS eco-bio + COMBIMASS Technical Data THE SYSTEM COMBIMASS The field transmitters of the COMBIMASS eco series are suitable for gas flow measurement and cover a wide range of different applications. The instruments

More information

How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer

How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer What is ICP-MS? and more importantly, what can it do? Inductively Coupled Plasma Mass Spectrometry or ICP-MS is an analytical technique used for elemental determinations. The technique was commercially

More information

TR Series Surface Roughness Tester for workshop and laboratory

TR Series Surface Roughness Tester for workshop and laboratory TR Series Surface Roughness Tester for workshop and laboratory Portable, rugged and instant operation on metallic and ceramic surfaces Surface roughness measurement the basics Application Surface roughness

More information

7. 1.00 atm = 760 torr = 760 mm Hg = 101.325 kpa = 14.70 psi. = 0.446 atm. = 0.993 atm. = 107 kpa 760 torr 1 atm 760 mm Hg = 790.

7. 1.00 atm = 760 torr = 760 mm Hg = 101.325 kpa = 14.70 psi. = 0.446 atm. = 0.993 atm. = 107 kpa 760 torr 1 atm 760 mm Hg = 790. CHATER 3. The atmosphere is a homogeneous mixture (a solution) of gases.. Solids and liquids have essentially fixed volumes and are not able to be compressed easily. have volumes that depend on their conditions,

More information

MUHAMMAD ABDULLAH AL-AZZAZ COMPANY LIMITED P.O. BOX 31172 AL-KHOBAR 31952 KINGDOM OF SAUDI ARABIA

MUHAMMAD ABDULLAH AL-AZZAZ COMPANY LIMITED P.O. BOX 31172 AL-KHOBAR 31952 KINGDOM OF SAUDI ARABIA This is to signify that MUHAMMAD ABDULLAH AL-AZZAZ COMPANY LIMITED P.O. BOX 31172 AL-KHOBAR 31952 KINGDOM OF SAUDI ARABIA Calibration Laboratory CL-151 has met the requirements of the IAS Accreditation

More information

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Innovation with Integrity Micro-CT 3D Microscopy Using Micro-CT for SEM Micro-CT for SEM

More information

Introduction to Elemental Analysis by ED-XRF Justin Masone Product Specialist 3 June 2015

Introduction to Elemental Analysis by ED-XRF Justin Masone Product Specialist 3 June 2015 Introduction to Elemental Analysis by EDXRF Justin Masone Product Specialist 3 June 2015 1 / 9 Shimadzu Corporation Established in 1875. Headquartered in Kyoto, Japan Ranked Top 5 Instrument Providers

More information

MODERN ATOMIC THEORY AND THE PERIODIC TABLE

MODERN ATOMIC THEORY AND THE PERIODIC TABLE CHAPTER 10 MODERN ATOMIC THEORY AND THE PERIODIC TABLE SOLUTIONS TO REVIEW QUESTIONS 1. Wavelength is defined as the distance between consecutive peaks in a wave. It is generally symbolized by the Greek

More information

Multilevel Socket Technologies

Multilevel Socket Technologies Multilevel Socket Technologies High Performance IC Sockets And Test Adapters Overview Company Overview Over 5,000 products High Performance Adapters and Sockets Many Custom Designs & Turn-Key Solutions

More information

XFA 600 Thermal Diffusivity Thermal Conductivity

XFA 600 Thermal Diffusivity Thermal Conductivity XFA 600 Thermal Diffusivity Thermal Conductivity Thermal Diffusivity, Thermal Conductivity Information of the thermo physical properties of materials and heat transfer optimization of final products is

More information

OLIVÉR BÁNHIDI 1. Introduction

OLIVÉR BÁNHIDI 1. Introduction Materials Science and Engineering, Volume 39, No. 1 (2014), pp. 5 13. DETERMINATION OF THE ANTIMONY- AND STRONTIUM- CONTENT OF ALUMINIUM ALLOYS BY INDUCTIVELY COUPLED PLASMA ATOM EMISSION SPECTROMETRY

More information

Würth Elektronik ibe Automotive solutions

Würth Elektronik ibe Automotive solutions Würth Elektronik ibe Automotive solutions July 2016 Page 1 The Würth Group The Würth Group Over 69,000 employees, 11 billion sales More than 400 companies In more than 80 countries The Würth Elektronik

More information

Thermal diffusivity and conductivity - an introduction to theory and practice

Thermal diffusivity and conductivity - an introduction to theory and practice Thermal diffusivity and conductivity - an introduction to theory and practice Utrecht, 02 October 2014 Dr. Hans-W. Marx Linseis Messgeräte GmbH Vielitzer Str. 43 D-95100 Selb / GERMANY www.linseis.com

More information

Lecture 35: Atmosphere in Furnaces

Lecture 35: Atmosphere in Furnaces Lecture 35: Atmosphere in Furnaces Contents: Selection of atmosphere: Gases and their behavior: Prepared atmospheres Protective atmospheres applications Atmosphere volume requirements Atmosphere sensors

More information

Table 1 Mixed-Signal Test course major topics. Mixed-signal Test and Measurement Concepts ENCT 351 What are Mixed-signal circuits

Table 1 Mixed-Signal Test course major topics. Mixed-signal Test and Measurement Concepts ENCT 351 What are Mixed-signal circuits Mixed-Signal Test Emphasis in Engineering Technology Rainer J. Fink, Jay Porter, Yong-Kyu Jung, B. Ben Zoghi Department of Engineering Technology and Industrial Distribution Texas A&M University College

More information

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT Shenzhen BST Technology Co., Ltd. SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT Prepared For : Product Name: Model : Prepared By : SHENZHEN GEMBIRD ELECTRONICS LTD 5th Floor, Building B, Shifeng Industry

More information

Design of Bidirectional Coupling Circuit for Broadband Power-Line Communications

Design of Bidirectional Coupling Circuit for Broadband Power-Line Communications Journal of Electromagnetic Analysis and Applications, 2012, 4, 162-166 http://dx.doi.org/10.4236/jemaa.2012.44021 Published Online April 2012 (http://www.scirp.org/journal/jemaa) Design of Bidirectional

More information