Waveguide Access Point WGA631. Product Guide
|
|
- Reynard Simon
- 2 years ago
- Views:
Transcription
1 Waveguide Access Point Product Guide
2 Waveguide Access Point Contents 1. Description Application Technical data Physical interfaces Mounting methods Ordering data Accessories and ordering data Tools Terminal diagram Disclaimer The information in this document is subject to change without notice and should not be construed as a commitment by ABB Oy. ABB Oy assumes no responsibility for any errors that may appear in this document. Copyright 2009 ABB Oy All rights reserved. Trademarks ABB is a registered trademark of ABB Group. All other brand or product names mentioned in this document may be trademarks or registered trademarks of their respective holders. 2 ABB
3 Waveguide Access Point 1. Description WaveGuide Access Point is a communication adapter for wireless local area networks (LANs) using waveguide technology. The adapters are attached to the waveguide tubes of the switchgear to provide communication for protection and control devices supporting the Ethernet based IEC protocol including the standard s GOOSE services. 2. Application Issued: June 2009 Revision: B / 23 June 2009 mounting and integration of the waveguide tube in the switchgear is done by the switchgear manufacturer. The unit is equipped with three galvanic RJ-45 interfaces which enable the connection of up to three IEDs located in the same low voltage compartment to one unit. However, only one coaxial antenna cable is needed to connect the to the waveguide tube. Furthermore, does not require any communication mapping contributes to a reduced need for wiring between switchgear and speeds up the commissioning phase of the switchgear. The communication system can be extended if needed by extending the waveguide tube and adding units. Fig. 1 application example enables in combination with the waveguide tube interference-free wireless Ethernet communication between IEDs in switchgear. acts as a converter between the galvanic connection and the wireless 5 GHz signal for the WaveGuide IEC station bus communication. The unit can be used in both gas (GIS) and air (AIS) insulated switchgear. The unit is placed next to the IED in the low voltage compartment of the switchgear. The NCC Station computer/ Gateway IEC or IEC IEC Waveguide IEEE802.11a IEC ABB 3
4 Waveguide Access Point Protection 3. Technical data Dimensions Width Height Depth Weight mm 71.0 mm mm 1.25 kg Power supply Description U aux nominal U aux variation Power consumption Connectors Interface Value V AC V DC % of U n ( V AC) % of U n ( V DC) ~5 W Type Waveguide connector R-SMA cable connector 1) Ethernet connector RJ-45 galvanic LAN connector 1) For example, Telegärtner R-SMA, J01150R0001 Communication Protocol type IEC Degree of protection by enclosure Front side IP 20 Top IP 40 Rear side IP 40 4 ABB
5 Waveguide Access Point Environmental conditions and tests Environmental conditions Operating temperature range ºC (continuous) Transport and storage temperature range According to IEC Test values: C Environmental tests Dry heat test (humidity <50%) According to IEC Test values: 96 h at +65ºC Start-up at +55ºC Dry cold test According to IEC Test values: 96 h at -40ºC Start-up at -40ºC Electromagnetic compatibility tests Power supply module The EMC immunity test level meets the requirements listed below: 1 MHz burst disturbance test, class IV: Common mode Differential mode According to IEC kv 2 kv Fast transient disturbance tests: According to IEC kv Surge immunity test: According to IEC kv, line-to-earth 2 kv, line-to-line Electromagnetic emission tests: Conducted, RF emission (mains terminal) Radiated RF emission According to EN EN ( MHz) IEC (80 MHz..,.1 GHz, 10 V/m) Enclosure The EMC immunity test level meets the requirements listed below: Electrostatic discharge test, class IV: For contact dischargecommon mode Differential mode Radio frequency interference tests: Conducted, common mode Radiated, amplitude-modulated According to IEC /- 8 kv +/- 8 kv According to IEC V (rms), f = 150 khz...80 MHz According to IEC V/m (rms), f = MHz ABB 5
6 Waveguide Access Point Protection Ethernet and WGA port The EMC immunity test level meets the requirements listed below: Fast transient disturbance test, class III According to IEC kv Radio frequency interference tests: Conducted, common mode According to IEC and IEC V (rms), f = 150 khz...80 MHz Mechanical tests Vibration tests (sinusoidal) According to DNV Standard for Certification No. 2.4, April 2001 EMC compliance Complies with the EMC directive 89/336/EEC Product safety Complies with the LV directive 73/23/EEC RoHS compliance Complies with the RoHS directive 2002/95/EC System requirements for the WINBOX tool Hardware requirements 10 MB free hard disk space RJ-45 interface for configuration with WINBOX RS-232 interface for configuration via script file download. Supported operating systems Microsoft Windows 2000, SP4 or later Microsoft XP Professional Edition, SP2 or later Microsoft Windows Server 2003 Default IP address configuration Description Value LAN-IP LAN-IP LAN-IP WLAN-IP ABB
7 Waveguide Access Point 4. Physical interfaces 1. RJ-45 Ethernet connector 1 2. Service port 3. RJ-45 Ethernet connector 2 4. RJ-45 Ethernet connector 3 5. Earthing screw 6. Coaxial waveguide interface 7. Auxiliary power supply connector 8. Power-up LED 9. Start-up LED 10. LAN and diagnostic LEDs 11. DIN rail mounting Fig. 2 Physical interfaces 5. Mounting methods WGA61 can by means of a standardized (EN 50022, DIN 46277, BS 5584) 35 mm top-hat mounting rail be mounted either horizontally or vertically in the low voltage compartment of the switchgear. However, horizontal mounting is recommended as it offers the best passive cooling of the unit. The clamps on the backside of enable disassembly of the unit if needed. The unit should be placed near the IED in order to minimize the length of the CAT 7 cable and the coaxial antenna cable. Fig. 3 Horizontal mounting in the low-voltage compartment of the switchgear ABB 7
8 Waveguide Access Point Protection 6. Selection and ordering data Use the ordering key information in Fig. 4 to generate the order number when ordering. The type and serial number label identifies the Waveguide Access Point unit. The label is placed the upper part of the unit. The order number consists of a string of codes generated from the hardware modules of the unit. W G A H # DESCRIPTION 1 Ethernet connectors 3 RJ45 connectors 3 2 Ports 1 5 GHz port 1 3 Power supply V AC, V DC H Fig. 4 Ordering key 7. Accessories and ordering data The delivery of the only includes the actual communications adapter. Accessories like cables, antennas and connectors are not supplied by ABB. Furthermore, the waveguide tube that connects the switchgear and enables interference free wireless communication must be produced and integrated in the switchgear by the switchgear manufacturers. Waveguide tube drawings can be downloaded from the inside.abb.com/substationautomation web portal. Waveguide tube drawings Document Waveguide tube - Variants for different switchgear types Waveguide tube End cover Waveguide tube - Details of the hole for the antenna interface Document ID 1VB VB VB ABB
9 Waveguide Access Point 8. Tools All units are delivered with the same set of preconfigured IP addresses for the galvanic RJ-45 interfaces and the wireless coaxial interface. The IP addresses can be changed using the Winbox configuration tool. Winbox further enables the configuration of as either a Master (AP-bridge) or a Client in slave mode (wds-slave). The Winbox tool can be downloaded from the unit s flash memory or from the inside.abb. com/substationautomation web portal. can in addition to the Winbox configuration tool be configured with the unit s RS-232 interface and a terminal program such as the open source TeraTerm software or any other RS-232 terminal program for script file download. Tools Tool Version Document ID Winbox configuration tool 1.0 1MRS ABB 9
10 Waveguide Access Point Protection 9. Terminal diagram Fig. 5 Terminal diagram 10 ABB
11
12 ABB Oy Distribution Automation P.O. Box 699 FI VAASA, Finland Phone Fax Copyright 2009 ABB. All rights reserved.
Arc Protection Module REA 103. Operator s Manual
Arc Protection Module REA 103 1MRS751004-MUM Issued: 05.11.2003 Version: C/09.06.2005 Arc Protection Module REA 103 1. About this manual...5 1.1. Copyrights...5 1.2. Trademarks...5 1.3. Guarantee...5
Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11
Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks. The MPU handles the absolute time and
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
Arc Protection Module REA 105. Operator s Manual
Arc Protection Module REA 105 1MRS751005-MUM Issued: 20.04.1998 Version: D/09.06.2005 Arc Protection Module REA 105 1. About this manual...5 1.1. Copyrights...5 1.2. Trademarks...5 1.3. Guarantee...5
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
Foxboro Evo Process Automation System
Foxboro Evo Process Automation System Product Specifications PSS 31H-2Z32 FBM232 Field Device System Integrator Module, 10/100 Mbps Ethernet, Single The FBM232 Field Device System Integrator (FDSI) module
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
SEL-2890 Ethernet Transceiver
Ethernet Transceiver Communicate With SEL Devices Using Ethernet Networks The Ethernet Transceiver is an EIA-232 serial-to-10base-t converter. The is powered by 5 Vdc provided on Pin 1 of the serial communications
LONWORKS Fibre Optic Converter
LONWORKS Fiber Optic Converter LRW-102 and LRW-102/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-102 is a fibre optic modem designed for multidrop and redundant ring
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
Communication Unit 560CMU05 Data sheet
RTU560 product line Communication Unit 560CMU05 Data sheet E1 10/100 MB LAN E2 10/100 MB LAN CP1, CP2 RS232C or RS485 Ethernet Controller Ethernet Controller USART Processor bus MPU ELAN520 /Flash Memory
Electronic timer CT-TGD.12
2CDC 251 098 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection
Disturbance Recoder SPCR 8C27. Product Guide
Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power
T200, PTP/IEEE 1588 Grandmaster Clock and
T200, PTP/IEEE 1588 Grandmaster Clock and NTP Time Server with high accuracy GPS receiver, OCXO or Rubidium oscillator 1 Bd d Armor 22300 LANNION - FRANCE contact@heoldesign.com 1 HEOL-T200 : PERFORMANCE
Binary input 520BID01 Data sheet
RTU520 product line Binary input 520BID01 Data sheet The module is available in two versions (rubrics): 520BID01 R0001: process voltage 24 to 60 V DC. LED signaling for each input, common return per 8
TX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
SYNCHROTACT CSS Synchronizing system for synchronous generators
SYNCHROTACT CSS Synchronizing system for synchronous generators Application Reliable synchronizing and paralleling SYNCHROTACT CSS (compact synchronizing system) is a combination system to parallel power
PHOENIX CONTACT - 03/2007
PSI-WL-PLUG-USB/ Bluetooth USB Adapter INTERFACE Data Sheet 103170_00_en PHOENIX CONTACT - 03/2007 Description The Bluetooth USB adapter provides an easy wireless connection between devices with a USB
TEST REPORT EN 55014-2 (1997) +A1 (2001)
Page 1 of 23 TEST REPORT EN 55014-2 (1997) +A1 (2001) Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Part 2: Immunity Report Reference No....
HCR3.2/.. Chipcard reader HOTEL SOLUTION
s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
IntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
Analog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
KNX Panasonic Air Conditioners
IntesisBox KNX Panasonic Air Conditioners Gateway for Panasonic ECOi and PACi system integration into KNX networks Up to 30 Outdoor units Up to 64 Indoor units PA-AC-KNX-64/128 EIA485 U1U2 line U1U2 line
C13 User Manual Document ID: 2CMC486004M0201 Revision: A 2013-06-19
C13 C13 Document ID: 2CMC486004M0201 2013-06-19 Disclaimer Copyrights Trademarks Contact The information in this document is subject to change without notice and should not be construed as a commitment
Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W
14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY
TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,
15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE
Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer
EGX100 Ethernet gateway
E90463 PB101556 The EGX100 serves as an Ethernet gateway for PowerLogic System devices and for any other communicating devices utilizing the Modbus protocol. The EGX100 gateway offers complete access to
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface
ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Indoor / Outdoor Antenna
z300 High Precision NTP Time Server Indoor / Outdoor Antenna High Precision NTP Time Server with PoE (Indoor or Outdoor use) synchronized by GPS Revision 4 ZTI / 1 boulevard d'armor / BP 20254 / 22302
H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.
Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.
Relion 605 series. Self-powered feeder protection REJ603 Product Guide
Relion 605 series Relion 605 series Relion 605 series Self-powered feeder protection Product Guide Product version: 3.0 Contents 1.... 3 2. Relay functions... 3 3. Protection functions... 4 4. Application...
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
HEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic
HEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic Heol fleet tracking system GPS N103 -OBD GPRS FTS Software Internet Main office - Control room Other office The specifications in this document
Disclaimers. Important Notice
Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means,
IntesisBox Modbus Server Fidelio IP
IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
Chrome DIN Rail Power Supply 12V 10W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
Modbus Server SAMSUNG Air Conditioners
IntesisBox Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung Air Conditioning Systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel ) Master TCP Master
Communicate and view data from meters with one simple device
Communicate and view data from meters with one simple device PowerLogic EGX300 integrated gateway-server Web Monitoring Communications Plug and Play Plug into your energy usage with a simple mouse click
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
USB-to-Data Highway Plus Cable
Installation Instructions USB-to-Data Highway Plus Cable Catalog Number 1784-U2DHP Topic Page Important User Information 2 Environment and Enclosure 3 Install the Cable 5 Configure the DH+ Node Address
Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134
AC 800M EtherNet/IP DeviceNet Linking Device LD 800DN SP1134 Power and productivity for a better world TM AC 800M EtherNet/IP DeviceNet Linking Device LD 800DN NOTICE This document contains information
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
S Page 608 Mar 2008 Siemens ITS
S7-200 Overview The new modular miniature controller from the SIMATIC S7 family Comprising: Controller with integrated PROFINET IO controller interface for communication between SIMATIC controllers, HMI,
Capacitor Protection Relay SPAJ 160 C. Product Guide
Issued: April 1999 Status: Updated Version: C/19.04.2006 Data subject to change without notice Features One-, two- and three-phase overload stage with definite time characteristic One-, two- and three-phase
s 8 186 TXB1.PROFINET PROFINET BIM TX-I/O
s 8 186 TX-I/O PROFINET BIM TXB1.PROFINET Interface between the automation station and the bus of the TX-I/O modules Compact format (to DIN43 880), small footprint Simple installation and easy access Self-establishing
Operating Manual UWAPS-TINY Series
Operating Manual UWAPS-TINY Series Powecon Oy WWW.POWECON.FI 1/9 Table of content 1 Warranty...3 2 Safety information...3 3 Abbreviations and terminology...3 4 List of appendices...4 5 Introduction...4
IntesisBox KNX Modbus TCP master
IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration
HARTING econ 7000 Introduction and features
Introduction and features HARTING econ 7000 es, unmanaged, for use in harsh industrial environments General Description Features The es of the product family HARTING econ 7000 allow, according to type,
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
Station Automation Series COM600 Protection and control from ABB Future-proof Concept: Extensive Substation System Integration and Interoperability The Station Automation Series COM600 is a dedicated system
Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server
Gain energy insight and control with PowerLogic PowerLogic EGX300 integrated gateway-server Plug into your energy usage with a simple mouse click The PowerLogic EGX300 is an integrated gateway-server that
HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB
Product datasheet Characteristics HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB Main Range of product Product or component type Display colour Display size Supply Magelis
Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class
Three-phase monitoring relay CM-PVE
Data sheet Three-phase monitoring relay CM-PE The three-phase monitoring relay CM-PE monitors the phase parameter phase failure as well as over- and undervoltage in three-phase mains. 2CDC 251 006 S0012
Trip circuit supervision relay. Type RXTCS
Trip circuit supervision relay Type RXTCS ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
Version Date Author Description 1.00 19.07.2010 Jpo First version 1.01 21.12.2010 Jpo FET output descriptions made clearer 1.02 04.02.
+3 # Version Date Author Description 1.00 19.07.2010 Jpo First version 1.01 21.12.2010 Jpo FET output descriptions made clearer 1.02 04.02.2011 Jpo Reset button added 1. Purpose of this user manual...
HP Server Console Switch with Virtual Media Overview
Overview HP's Server Console Switch with Virtual Media is a key component in managing the data center. Connections for two local consoles (a console represents one keyboard, monitor and mouse) allow access
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
OZS164... Web server. For LPB/BSB plants
s 5 711 Web server For LPB/BSB plants OZS164... Remotely operate and monitor a LPB or BSB device Web browser operation via PC/laptop or Smartphone SMS operation via mobile phone (OZS164.23) 2 digital inputs
PRO 5000 CPE 1D Quick Installation Guide
PRO 5000 CPE 1D Quick Installation Guide Introduction This Quick Installation Guide covers the basic installation of the PRO 5000 CPE. For more information, refer to the relevant sections in the Product
The Intel NetStructure SIU520 Signaling Interface
The Intel NetStructure SIU520 Signaling Interface Intel in Communications The Intel NetStructure SIU520 signaling interface unit (SIU) provides Signaling System 7 (SS7) connectivity for multichassis call
AMIS. Automated Metering and Information System. Integration of meters from other manufacturers
AMIS Automated Metering and Information System TD-3530/TACU30 Third-Party Device Gateway Integration of meters from other manufacturers Connection and integration of max. 3 meters from third party manufactureres
QuickSpecs. HP IP Console Switches. Overview
Overview The HP IP console switch provides keyboard, video and mouse (KVM) connections to up to 16 direct attached servers. Users can tier this switch with HP Server Console Switches, 8-Port CAT5 KVM Expansion
Storage System. Planning Checklist. EC1434-2-E1, First Edition
Storage System Planning Checklist EC1434-2-E1, First Edition Proprietary Rights Notice This document contains proprietary information of Engenio Information Technologies, Inc. and Storage Technology Corporation.
PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version 2.1.0 (2013-11-15)
PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN User Manual Document version 2.1.0 (2013-11-15) Products taken into account Product Name Model Part number PCAN-B10011S IPEH-002041 CANopen
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new
Test Report #: 1981-3 Date: April 8, 2005
Test Report #: 1981-3 Date: April 8, 2005 CERTIFICATE #2316.01 Issued To: Bill Burks American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description Model
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
DATA LINK CONVERTER RS 232 / RS 485
Via M.E. Lepido, 182-40132 BOLOGNA - P.O.BOX 4052 BorgoPanigale Tel.: +39 051 404140 - Fax: +39 051 402040 - WEB: www.ducatienergia.com DATA LINK CONVERTER RS 232 / RS 485 USER S MANUAL 0798 Table of contents
PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based
PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based Description Silicom s quad port Copper 10 Gigabit Ethernet Bypass server adapter is a PCI-Express X8 network interface
1756 ControlLogix Chassis Specifications
Technical Data 1756 ControlLogix Chassis Specifications Catalog Numbers 1756-A4/B, 1756-A4K/B, 1756-A4/C, 1756-A4K/C, 1756-A7/B, 1756-A7K/B, 1756-A7/C, 1756-A7K/C, 1756-A10/B, 1756-A10K/B, 1756-A10/C,
C11 User Manual Document ID: 2CMC486001M0201 Revision: A
C11 C11 Document ID: 2CMC486001M0201 2010-12-13 Disclaimer Copyrights Trademarks Contact The information in this document is subject to change without notice and should not be construed as a commitment
Application Server V240 Platform
Application Server V240 Platform The V240 Application Server (V240) features four hot-swappable disks with redundant power supplies for reliable system performance. The server also has three PCI slots
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
C24-CAMANL Video Server/Encoder
C24-CAMANL Video Server/Encoder User s Guide Table of Contents CHAPTER 1 INTRODUCTION... 1 Overview... 1 Physical Details - Video Server... 2 Package Contents... 3 CHAPTER 2 BASIC SETUP... 4 System Requirements...
Terminal and Dimension
Ethernet Extender Model Number: SJ-L-DSL Complete Installation Guide Product Description Product Features SJ-L-DSL is network signal extension device, which consists of remote unit and local unit. It can
EMR. WAN Compact Router for Industrial Ethernet Networks. A secure access to Ethernet industrial networks making use of the public operator networks
WAN Compact Router for Industrial Ethernet Networks A secure access to Ethernet industrial networks making use of the public operator networks GPRS, Edge, UMTS, HSDPA...a wide range of transmission technologies
Substation Automation Products Relion 670/650 series IEC and ANSI Hardware
Substation Automation Products Relion 670/650 series IEC and ANSI Hardware ABB Group 1MRG014097 October 2013 Relion 670/650 series hardware Contents Relion 670/650 series Relion Hardware Relion Common
Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter
Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Serial Interface One RS-232 port and one RS-422/485 port to 10/Base- TX Media Conversion Cost effective solutions of RS-232/ RS-422/ RS-485
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Thermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS IS 12729:2004 IEC 60694(2002) 1.1 Scope This International Standard applies to a.c. switchgear and controlgear,