LOCATION. By Taxi Taxis are readily available to and from 28 Hennessy Road. ACCESSIBILITY. Kowloon Tong
|
|
- Godfrey York
- 8 years ago
- Views:
Transcription
1
2
3 28 Hennessy Road is the latest addition to the Swire Offices portfolio. Served by the Admiralty MTR station and located close to Three Pacific Place and Star Street Precinct, this 28-storey building offers an excellent business environment built to top class specifications. While enjoying a dedicated covered vehicle drop-off with car parking available at Three Pacific Place, 28 Hennessy Road also offers a uniquely designed sky garden on the second floor, which is an inspiring, rare-to-be-seen facility in the hustle-andbustle of Hong Kong. 28 HENNESSY ROAD With its superior design features and eco-friendly building specifications, 28 Hennessy Road is set to achieve the highest Platinum rating in accordance with the Building Environmental Assessment Method (BEAM). 1
4 Superbly situated for business, 28 Hennessy Road enjoys the dual advantages of a prime location and swift, direct routes to anywhere in Hong Kong. It is also well served by a dedicated covered vehicle drop-off with car parking available at Three Pacific Place. By MTR 28 Hennessy Road has easy access to Admiralty MTR station, which itself is an interchange for the comprehensive railway network serving both sides of the harbour. This is set to be enhanced further with the new South Island line and proposed Shatin Central line, making Admiralty a true hub. Located within the proximity of Pacific Place, one of Hong Kong s landmark addresses, 28 Hennessy Road is an advanced, state-of-the-art premises for business. LOCATION By Bus & By Tram Over 80 bus routes, including the CityFlyer airport express bus service, serve the immediate area. Trams, one of the most environmentally friendly means of transportation, also stop at the door front. By Taxi Taxis are readily available to and from 28 Hennessy Road. ACCESSIBILITY Kowloon Tong TRAVEL BY CAR 5 MIN to Central 6 MIN to Hong Kong Airport Express Station 12 MIN to Tsim Sha Tsui 12 MIN to Hung Hom MTR Station TRAVEL BY 3 MIN to Central 5 MIN to Causeway Bay 5 MIN to Tsim Sha Tsui 17 MIN to Kowloon Tong Offices Serviced Apartments Park Mass Transit Railway Station Shopping Centre Hotel Underground Pedestrian Link Tsim Sha Tsui Central Admiralty Wanchai Causeway Bay 2 3
5 Tenants of 28 Hennessy Road benefit from both the distinctive entertainment and retail destination of Pacific Place and the variety of the unique dining and shopping outlets of Star Street Precinct and neighbouring areas. NEIGHBOURHOOD 4 5
6 The design of the building fulfils the stringent requirements of the Platinum rating by the Building Environmental Assessment Method (BEAM). Tenants of 28 Hennessy Road can rest assured that the building is designed and operated to the highest environmental standards. Besides, a unique landscaped sky garden located on the second floor also serves as a relaxing and tranquil zone for leisure and enjoyment. GREEN VALUES Open floor plates of over 4,900 sq ft lettable Generous ceiling height of 2.85 m (9 ft 4 in) Octopus card key system integrated with the passenger lifts enables access to all office floors. A dedicated, professional building management team is committed to ensuring that your business runs smoothly with the implementation of discreet patrolling, security and fire precaution systems. Telecommunications and Broadcasting Equipment (TBE) room with dual lead-ins and Cat.5e and fibre optic cabling. Access to all fixed telecom network (FTNS) operators. Complete choice of terrestrial, cable TV, satellite television channels and broadband internet services. Free wi-fi coverage in the main lift lobby and sky garden. Full mobile telephone coverage throughout the building, lifts and back-of-house areas. YOUR OFFICES 6 7
7 KEY SPECIFICATIONS SCHEDULE OF AREAS Number of floors : 28 Number of office floors : 24 Mullion to mullion distance Typical curtain wall to core wall distance Typical raised floor to finished ceiling height Raised access floor system Floor loading Passenger lifts : 1.6 m (approx. 5 ft 3 in) : Deep floor span offers up to 17 m (55 ft 9 in) depth and up to 26.3 m (86 ft 3 in) width specifically for modern, efficient office layouts : Approx m (9 ft 4 in) : A 150 mm (6 in) raised / access floor system with 100 mm (4 in) clear void comprising of 600 mm x 600 mm floor tiles and fitted with 3-compartment service outlet boxes for ease of connection to all power, voice and data equipment : Approx. 5 kpa (100 lbs / sq ft) : Four (1,800 kg) high-speed passenger lifts Service lift : One (4,600 kg) lift (Dimensions 1.67 m W x 1.98 m D x 2.9 m H) Building access control Curtain wall Air-conditioning design provision Open-plan lighting level : Octopus card key system incorporated with the passenger lifts for controlling access to each office floor after office hours : Low-e double-glazed thermally-insulated panels set in aluminium frames with PVDF coating : Variable Air Volume (VAV) system with Direct Digital Control (DDC) designed to an occupational capacity of 8 sq m per person : 500 lux average at desk level by energy-efficient T5 fluorescent tubes and electronic ballasts Electrical loading design provision : 89 VA/sq m (approx. 8.3 VA/sq ft) Dual busduct risers for power supply Stand-by electrical provision Essential equipment cooling Telecommunications provision Car parking : A 500 kva emergency generator is provided for tenants essential applications and equipment : Dedicated 24-hour chilled water supply with emergency generator back-up : Dual lead-ins and risers Full Cat.5e and fibre optic cabling Cable containment for tenants inter-floor cabling Free choice of all FTNS operators Access to SMATV, cable TV and broadband internet services : Available at Three Pacific Place Location Use Gross Floor Gross Floor Lettable Floor Lettable Floor Net Floor Net Floor Efficiency Area (sqm) Area (sq ft) Area (sqm) Area (sq ft) Area (sqm) Area (sq ft) (Net/Lettable) 28/F Office , , , % 27/F Office , , , % 26/F Office , , , % 25/F Office , , , % 24/F Office , , , % 23/F Office , , , % 22/F Office , , , % 21/F Office , , , % 20/F Office , , , % 19/F Office , , , % 18/F Office , , , % 17/F Office , , , % 16/F Office , , ,251 86% 15/F Office , , ,251 86% 14/F Office , , ,251 86% 13/F Office , , ,251 86% 12/F Office , , ,251 86% 11/F Office , , ,251 86% 10/F Office , , ,251 86% 9/F Office , , ,251 86% 8/F Office , , ,251 86% 7/F Office , , ,251 86% 6/F Office , , ,251 86% 5/F Office , , ,251 86% 4/F Mechanical Floor 3/F Refuge Floor 2/F Sky Garden 1/F Main Lobby G/F Main Entrance LG/F Mechanical Floor 8 9
8 TYPICAL FLOOR PLAN CROSS-SECTIONAL PLAN Approx m (86 ft 3 in) Approx. 17 m (55 ft 9 in) Typical curtain wall to core wall distance Approx. 17 m (55 ft 9 in) Typical finished floor to false ceiling height Approx m (9 ft 4 in) Window cill height 650 mm Raised floor void Approx. 150 mm (6 in) with 100 mm (4 in) clear void Floor loading Approx. 5 kpa (100 lbs / sq ft) Lettable Floor Area : Approx. 4,900 sq ft (460 sq m) Net Floor Area : Approx. 4,250 sq ft (395 sq m) 10 11
9 HIGH DENSITY SPACE PLAN LOW DENSITY SPACE PLAN Enclosed office : 2 General staff : 54 Receptionist : 2 Total : 58 Reception : 1 Meeting room : 2 Breakout / discussion area : 2 Server room : 1 Equipment / filing area : 2 Enclosed office : 5 General staff : 32 Receptionist : 1 Total : 38 Reception : 1 Meeting room : 2 Discussion area : 4 Server room : 1 Equipment / filing area : 2 Pantry :
10 LANDLORD S PROVISIONS The Building The structural system of this building comprises reinforced concrete structural walls coupled with four reinforced concrete columns. The floor system on a typical office floor is constructed by a 300 mm deep pre-stressed concrete flat slab with 650 mm deep perimeter beams for enhanced headroom. External Finishes The building is clad with low-e double-glazed, thermally-insulated panels set in aluminium frames with PVDF coating. Vertical mullions are set at 1.6 m (approx. 5 ft 3 in) intervals. Raised Floor System A fully installed 150 mm (6 in) raised / access floor system with 100 mm (4 in) clear void is provided, comprising of 600 mm x 600 mm floor tiles and fitted with 3-compartment service outlet boxes for ease of connection to all power, voice and data equipment. Vertical Transportation There are four high-speed passenger lifts serving the office floors operating at a speed of 7 metres per second with a capacity of 1,800 kg each. There is one service lift serving all floors of the building operating at a speed of 2.5 metres per second with a capacity of 4,600 kg. Main Lift Lobby and Sky Garden Lobby The Main Lift Lobby and the Sky Garden Lobby are finished with natural stone flooring and a feature wall of backlit marble. There is a bronze clad staircase linking the two lobbies. Office Area Core walls and columns to office areas are finished in plaster and emulsion paint ready for tenants finishes. Typical distance from core wall to internal curtain wall is approx. 17 m (55 ft 9 in). Typical width from curtain wall to curtain wall is approx m (86 ft 3 in). Washrooms Male, female and disabled washrooms are provided on every floor with white sanitary ware and stainless steel accessories. The floors in the washrooms are finished in white conglomerate stone and the walls are finished in a combination of white conglomerate stone and brown mosaic tiles. The ceiling of suspended metal panels and gypsum board incorporates lighting and ventilation fittings. Pantries ELECTRICAL INSTALLATION Normal Power The electrical loading per floor is designed at 89VA/sq m (approx. 8.3VA/sq ft) for office floors. The supply voltage is 380 volts, 50Hz, 3-phase or 220 volts, 50Hz, 1-phase. The building is divided into two zones with each zone served by two busducts to ensure uninterrupted power supply. Emergency Power A 500 kva standby emergency power system providing 44VA/sq m (approx. 4VA/sq ft) is available to back-up tenants essential equipment in the event of power interruption. Trunking A three-compartment cableway system is provided along the core on each floor for tenants flexible and convenient management of power and telecommunications system cabling. Computer Earthing A clean earthing system has been provided on each floor inside the meter room. Provision is made in the service core for plumbing, drainage and ventilation for permitted tenants pantries. Floor Loading Total floor loading is approx. 5 kpa (100 lb/sq ft) in the general office area
11 TELECOMMUNICATIONS & INFORMATION TECHNOLOGY MANAGEMENT Telecommunications Dual lead-ins and risers are provided to enhance the availability and resilience of the telecommunications services. Tenants enjoy a free choice of fixed telecom network services (FTNS) and operators. SMATV Facilities for satellite TV are in place. Splitter units for satellite TV, to which tenants can make connections, are available on every floor. Data Communication Inter-floor telecommunications trunking is provided inside the telephone duct room on every floor. Computerised Fire Detection Intelligent fire-detection systems have been provided and can be extended to tenants computer rooms. Wi-fi Connectivity Provision for free wi-fi coverage is provided in the main lift lobby and sky garden. FIRE PROTECTION SYSTEM BUILDING MANAGEMENT SYSTEM Automated Building Management System An automated building management system monitors and supervises all fire, life and safety services. The system also controls lighting in public areas and adjusts air-conditioning temperatures to ensure environmental comfort and safety at all times while maintaining energy efficiency. Public Address System Speakers are installed in the offices, washrooms and lift lobbies on each floor as well as in lift cars to broadcast emergency messages. A phased evacuation system broadcasting over the public address system provides automatic evacuation signalling and selective paging to all areas. Security The building is monitored on a 24-hour basis by a digital security surveillance system which covers all major access / exit points, lift cars and other common areas. An Octopus card key system, integrated within the passenger lifts, is available to tenants for controlling access to their premises. A computerised security patrol monitoring system is installed in all circulation areas and staircases. Door contacts are installed at all fire exits to enable movement to be monitored by the Building Management System. Automatic Sprinkler System The building is protected by an automatic sprinkler system. Wet riser and hose reel systems are also provided. Automatic Fire Alarm Systems (AFA) The building is further protected by a fire detection and alarm system which consists of visual / audio alarms and fully addressable heat detectors, smoke detectors, break glass units and flow switches. On activation of the AFA, fire alarm signals will be sent to the Building Control Room and directly to the Fire Services Department
12 INTEGRATED CEILING SYSTEM Office Ceiling The suspended ceiling system comprises suspended metal ceiling tiles (600 mm x 600 mm panels with sound absorbent material) and integrated lighting with air-conditioning outlets set in a modular layout. Concealed type sprinkler heads are also included. The floor to ceiling height provides a typical clear headroom of 2.85 metres on typical floors.this is enhanced to 3.4 metres on the top two office floors. Lighting Fully recessed 600 mm x 600 mm innovative direct and indirect luminaires with T5 fluorescent tubes and electronic ballasts permit desktop illumination of approx. 500 lux in an energy-efficient manner. There is flexibility to set the lux level at different intensities to reduce glare so as to achieve energy saving and environmental objectives. 600 mm x 600 mm Light Trough Sprinkler Head 18 19
13 AIR-CONDITIONING & VENTILATION Air-conditioning System A fully-fitted Direct Digital Control Variable Air Volume (VAV) system is provided on each office floor. Conditioned air is distributed through flexible ducts within the ceiling void to linear supply diffusers incorporated with the luminaires. VAV controllers with cooling and heating controls at perimeter zone are also provided for future heater installations. The air-conditioning system on a standard office floor has been designed to cater for a population density of 8 sq m (approx. 90 sq ft) per person and the total A/C load of lighting and small power up to 53W/sq m (approx. 5W/sq ft). Ventilation Tenants general exhaust is provided on each floor with capability to extend to pantry, conference rooms or dedicated exhaust from computer rooms. Washroom exhaust is provided by centralised exhaust systems. Essential cooling / air-conditioning The building is provided with a dedicated 24-hour chilled-water supply fed by a chiller with a total cooling capacity of 100TR. All chillers use environmentally friendly R134a refrigerant. Connections to the system on each floor enable tenants to cool their computer and data rooms. The chilled water supply is supported by the landlord s essential power system. Air Duct VAV Box 600 mm x 600 mm Light Trough Light Trough Incorporating A/C Louvres 20 21
14 Disclaimer Whilst every care has been taken in preparing this brochure, all statements contained are made without responsibility on the part of Swire Properties and no warranty whatsoever is given by Swire Properties, its servants or agents in respect of the correctness of the information. None of the statements contained in this brochure is to be relied upon as a statement or representation of fact. Any intending tenant must satisfy himself by inspection or otherwise as to the correctness of all statements contained.
15
50 St Mary Axe London EC3
50 St Mary Axe London EC3 Letting specification 1.Structure and Envelope The main superstructure comprises of a braced steel fame (app 7m span / 90min fire rated) and the elevations are formed from a series
More informationOur data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.
AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled
More informationLife isn t just how you feel about your home. It s how you feel about yourself when you are home.
Artistic Rendering Life isn t just how you feel about your home. It s how you feel about yourself when you are home. Emerald Hills - an exclusive gated, secure, impeccably planned development in Gurgaon
More information- 5 - Table1. Maximum Compartment Volumes
- 5 - Part II - SPECIFIC REQUIREMENTS 5. Compartmentation 5.1 Every building should be divided into compartments by walls and floors to inhibit the spread of fire. 5.2 Compartment walls, compartment floors,
More informationCONDUIT MAYFAIR READY FOR OCCUPATION SPRING 2014 GLINSMANWELLER.CO.UK A DEVELOPMENT BY LONDON PROPERTY PARTNERSHIP LTD
12 CONDUIT S T R E E T MAYFAIR READY FOR OCCUPATION SPRING 2014 020 7495 2728 GLINSMANWELLER.CO.UK A DEVELOPMENT BY LONDON PROPERTY PARTNERSHIP LTD 12 CONDUIT STREET The entire building is undergoing a
More informationTHE LEONARDO BUILDING crawley business quarter gatwick THE LOWEST COST PER WORK STATION IN THE SOUTH-EAST
THE LEONARDO BUILDING crawley business quarter gatwick THE LOWEST COST PER WORK STATION IN THE SOUTH-EAST THE LEONARDO BUILDING - Designed to meet BREEAM Excellent 2011 & EPC B Rating GATWICK AIRPORT proposed
More informationFire. The Fire Installers Mate. A guide to fire alarm systems design
Fire The Fire Installers Mate A guide to fire alarm systems design BS 5839 Part 1:2002 A guide to BS 5839 Part 1:2002 Disclaimer This booklet is not intended to be a comprehensive guide to all aspects
More informationOFFICE SPACE FOR LEASE THE WEST MALL TORONTO, ON
BO N $1 US.2 0 P CO M SF M /A I NN SIO UM N OFFICE SPACE FOR LEASE Up to 40,000 sf contiguous available Building under new ownership and management Currently undergoing building upgrades For more information,
More informationBalderton Mayfair London W1 Tenants Guide
Balderton Mayfair London W1 Tenants Guide Contents 01 Executive Summary 02 Location 03 Floor areas 03.1 Ground Floor 03.2 1st Floor 03.3 2nd 5th Floor 03.4 6th Floor 03.5 7th Floor 03.6 8th Floor 04 Space
More informationSPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME)
SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME) Construction Criteria The unit costs for ADP Mainframe space types are based on the construction quality and design features in the following
More informationPark View Place. Compass. House. Royal Wharf Gardens Endeavour. House. Thameside. Sienna. House. House. Apartments Townhouses.
The Townhouses Park View Place A A Compass House A T T T Royal Wharf Gardens Endeavour House T A A Thameside House T Sienna House A A A A T Apartments Townhouses River Thames Compass House Compass House
More informationOur data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.
AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled
More informationFire Safety In High Rise Building
Fire Safety In High Rise Building CLASSIFICATION OF BUILDINGS AS PER NATIONAL BUILDING CODE 1. GROUPING. Group A - Residential : Lodgings, Dwellings, Dormitories, Flats, Hotels. Group B Group C - Educational
More informationOccupancy: Assembly (A-3) and Business -Includes offices, seminar rooms, classrooms, and café facility. Duke University Medical School
Introduction Background The Duke School of Nursing building offers a new three-story state of the art facility that has helped strengthen the quality and integrity of the School of Nursing at Duke. The
More informationhong kong//china data center specifications tel: +61 2 9948 8888 fax: +61 2 9948 1111 internet + intellectual property + intelligence
internet + intellectual property + intelligence We thank you for the opportunity to work with you regarding your colocation needs in Hong Kong, China. We can colocate standard rack-mountable servers or
More informationCODE OF PRACTICE FOR THE PROVISION OF ACCESS FACILITIES IN BUILDINGS FOR THE SUPPLY OF TELECOMMUNICATIONS AND BROADCASTING SERVICES
Document Ref. No.: CoP-1/01 CODE OF PRACTICE FOR THE PROVISION OF ACCESS FACILITIES IN BUILDINGS FOR THE SUPPLY OF TELECOMMUNICATIONS AND BROADCASTING SERVICES COMMUNICATIONS AUTHORITY April 01 Contents
More informationSPECIFICATIONS FOR VASWANI BRENTWOOD PROJECT. RCC Framed Structure confirming with zone II seismic detailing. Reinforced Cement Concrete
SPECIFICATIONS FOR VASWANI BRENTWOOD PROJECT 1. CONSTRUCTION: Foundation Super Structure Internal Walls External Walls Roof Retaining Walls RCC footing RCC Framed Structure confirming with zone II seismic
More informationTO LET. Modern Office Suites in comprehensively refurbished building. 62 Brandon Parade Holly Walk, Leamington Spa, CV32 4JE
TO LET Modern Office Suites in comprehensively refurbished building 62 Brandon Parade Holly Walk, Leamington Spa, CV32 4JE First floor - 1,260 sq ft (117.05 sq m) Second Floor 1,500 sq ft (139.35 sq m)
More informationFIRE DETECTION AND ALARM SYSTEMS
HMO Information Sheet No 1 FIRE DETECTION AND ALARM SYSTEMS 1. Introduction When a property is in multiple occupation, the risk of fire breaking out is greater than in an ordinary single family home. Some
More information110 BISHOPSGATE, EC2
110 BISHOPSGATE, EC2 FOREWORD It is my firm belief that the Salesforce Tower is the finest commercial accommodation proposition in the world today. This brochure will identify the many specific merits
More informationSPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY
SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY Construction Criteria The unit costs for (Wet) space types are based on the construction quality and design features in the following table. This
More informationProposed Residential Complex At Holding No. - 98, B.T. Road, Kolkata - 700090 Developer Premier Mica Mining And Manufacturing Company
RISK MANAGEMENT PLAN is an integral part of a modernized and sophisticated residential complex. No efforts will be spared in identifying the all possible risks and disasters, evaluating them, installing
More informationFire Safety Requirements for Child Care Centre
Fire Safety Requirements for Child Care Centre A. Restrictions on Location Child care centre shall not be located : - (a) (b) in any premises designed for residential use; in any industrial building, warehouses,
More informationTurnkey Projects, Conversions, Restorations & Property Management. Marsalforn - Gozo APARTMENT FINISHING EXCLUSIVE PACKAGE
Turnkey Projects, Conversions, Restorations & Property Management Marsalforn - Gozo APARTMENT FINISHING EXCLUSIVE PACKAGE Reg. Office: Karlu Galea Street, Victoria, Gozo Malta. T. 2155 6600 M. 9943 4391
More informationConnect Transform Locate
A modern business space for modern business, located within an integrated transport hub. Up to 29,052 sq ft New Build Grade A BREEAM rated excellent Office accommodation. Wolverhampton. Making it happen
More informationI.S. 3218 :2013 Fire Detection & Alarm Systems
I.S. 3218 :2013 Fire Detection & Alarm Systems Overview of significant changes 26 th March 2014 FPS Ltd Today s Programme Commencement Transition Competence & Qualifications System Certification System
More informationEngineers Edge, LLC PDH & Professional Training
510 N. Crosslane Rd. Monroe, Georgia 30656 (770) 266-6915 fax (678) 643-1758 Engineers Edge, LLC PDH & Professional Training Copyright, All Rights Reserved Engineers Edge, LLC An Introduction to Communication
More informationI.S. 3218 :2013 Fire Detection & Alarm Systems
I.S. 3218 :2013 Fire Detection & Alarm Systems Overview of significant changes 26 th March 2014 FPS Ltd Today s Programme Commencement Transition Competence & Qualifications System Certification System
More informationLogisticsCentre IV Distribution Center
KCI Intermodal BusinessCentre LogisticsCentre IV LogisticsCentre IV Distribution Center Modern Warehouse/Distribution Space Ranging From 108,000± SF to 432,000± SF 10221 NW Transcon Drive 112th Street
More informationFIRE-FIGHTING DESIGN BRIEF REPORT
P a g e 1 SECTION 04 (Doc.No.A/DBR 001) FIRE-FIGHTING DESIGN BRIEF REPORT P a g e 2 1.0 SCOPE 2.0 STANDARDS AND CODES 3.0 TYPES OF SYSTEM PROPOSED 4.0 FIRE HYDRANT SYSTEM 5.0 AUTOMATIC SPRINKLER SYSTEM
More informationIFE Level 4 Certificate in Fire Science and Fire Safety (HL)
IFE Level 4 Certificate in Fire Science and Fire Safety (HL) Unit 2: Fire Safety Unit Reference Number: D/505/5932 Introduction This unit focuses on the prevention and detection of fire in premises and
More informationSummary of Preliminary Assessment on Structural, Fire and Electrical Safety
Name of the Factory Address of the Factory Present Status of the Factory Structural Assessment Conducted by : Galaxy Stitch Ltd. : BSCIC Industrial Estate, Plot no. A102, Tongi Gazipur Bangladesh : Under
More information3 BHK PRECIOUS HOMES KHARADI
3 BHK PRECIOUS HOMES KHARADI IMPRESSIVE LUXURY Precioso is a landmark offering from Global. Here, enviable location combines with careful planning while aesthetic architecture blends with meticulous finish
More informationDoc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC
TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while
More informationFire Alarm system Installation Guide
Fire Alarm system Installation Guide Fire Alarm System Categories Systems designed for Protection of Property only, fall into two classifications P1 or P2. but a manual system is also needed, then this
More informationOur data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.
AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled
More informationridgway office ParK progress WAy, denton, manchester, m34 2gp
Home ridgway House millenium House availability site PLaN gallery LocaTioN contact ridgway office ParK progress WAy, denton, manchester, m34 2gp To LeT / may sell To LeT HIgH QuALITy, AIR CondITIonEd offices
More informationNOVEMBER 2010 Photo 1 Floor fitout is now substantially completed up to level L34, and plantroom installations are also near completion. Internal Inspections and de-snagging are in progress up to level
More informationSaffron Square (Keats) Unit 6.05 apt 36
Saffron Square (Keats) Unit 6.05 apt 36 Saffron Square is an exciting new landmark situated in the heart of Croydon. A new and stylish building in Croydon offers 1, 2 and 3 bedroom apartments in this secure
More informationChips New Islington Manchester
ew Islington Manchester Apartments for sale or to rent isn t your average building. It s a bit of a one off and is one of the most significant buildings in ew Islington, Manchester s Millennium Community.
More informationHDA -----------------------------------------------------------
----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS
More informationLogisticsCentre IV Distribution Center
KCI Intermodal BusinessCentre LogisticsCentre IV Project Advantages Lowest occupancy cost for quality development for short term and long term occupancy Platte County workforce ranks higher than metro
More informationITEM DESCRIPTION SPECIFICATION TENDER OFFER
TECHNICAL SPECIFICATIONS PL1 & PL2 PLEASE TICK IF YOU COMPLY. SPECIFY YOUR OPTION IF YOU DON'T. ITEM DESCRIPTION SPECIFICATION TENDER OFFER Make (please specify) 1.0 Type Duplex Passenger Lift 2.0 Minimum
More informationLOGISTICS FACILITY UNITS AVAILABLE FROM 17,500 TO 130,000 SQ FT NEW BUILD PLANNING APPROVED
NEW BUILD LOGISTICS FACILITY UNITS AVAILABLE FROM 17,500 TO 130,000 SQ FT PLANNING APPROVED NEW BUILD LOGISTICS FACILITY UNITS AVAILABLE FROM 17,500 TO 130,000 SQ FT Located at Airport City Manchester
More informationCITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov
CITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov Finishing a basement to make additional living space in a house is a popular construction project for many homeowners.
More informationA VIBRANT NEW BUSINESS DISTRICT FOR LONDON
A VIBRANT NEW BUSINESS DISTRICT FOR LONDON THE MITRE BUILDING IS AN OUTSTANDING OFFICE BUILDING AT THE HEART OF CENTRAL LONDON S NEWEST BUSINESS DISTRICT, GREENWICH PENINSULA 20 MINUTES TO THE WEST END
More informationTHE NEW FORMAT OF BUSINESS
THE NEW FORMAT OF BUSINESS Office Complex & Retail San Gally Park Ligovskiy Prospekt 60 62. St. Petersburg. Russia Disclaimer Neither this brochure nor any of then details contained herein constitute part
More informationPollution CO CO 2. Carbonaceo us soot H 2 S, NOX, SO2
Pollution CO CO 2 Carbonaceo us soot H 2 S, NOX, SO2 The National Building Code (NBC) contains set of minimum provisions, designed to protect the safety of the public with regard to structural sufficiency,
More informationBuilding Condition Assessment Report
C2 - Nurses Resident (aka Administration) Building Condition Assessment Report Asset Address Address Construction Year Size (Gross Floor Area) Asset Type Floors Above Ground Inspection Date C2 - Nurses
More informationReplacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay
Original HVAC Units: Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue Photo Essay One fan motor draws air from the lower section of the unit,
More informationP r o j e c t C a s e S t u d y
P r o j e c t C a s e S t u d y Mangrove Place Project: Mangrove Place Start Date: 2009 Completion Date: Ongoing Location: Al Reem Island, Abu Dhabi, UAE Industry: Residential Developer: Luxury Real Estate
More informationNew Ontario Building Code Requirements for Mid-rise Wood Frame Buildings
New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings Note: This information addresses complex issues in a summary fashion. Consideration should be given to the official version of the
More informationAppendix G. Security management plan
Appendix G Security management plan Security Management Plan Prepared by: Kann Finch Group Project Energy Australia Belmore Park Zone 1- Sub-station component General Design Requirements The perimeter
More informationACCESS AUDIT OF WESTPORT HOUSE
ACCESS AUDIT OF WESTPORT HOUSE Large sign on the highway to indicate the entrance to Purbeck District Council Large and wide entrance Entrance showing sign for opening times Entrance sign Main entrance
More informationSchedule B to By-law 33-2009
Amended by By-law 8-2016 Note: This consolidation is prepared for convenience only. For accurate reference the original by-laws should be reviewed. Floor Area Calculation Floor area shall: Schedule B to
More informationFacility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components
Infrastructure Facility Condition Summary Weighted Avg Condition Score Facility Components Systems Surveyor/ Date Done Comments G Sitework.9 Site Improvements Parking Pedestrian Paving Site Development
More informationFire precautions in dwellings. Private sector housing Providing homes building communities
Fire precautions in dwellings Private sector housing Providing homes building communities Version 3 Published by Norwich City Council August 2011 Contents Page Introduction 1 2 Types of dwellings (A) Shared
More informationCyprus Freephone: Moscow St Petersburg Kiev Athens United Kingdom
The Oval / Cyprus +37 81 616 Freephone: 8000 0 30 Moscow +7 49 643 1901 St Petersburg +7 81 33 7118 Kiev +38 044 49 791 Athens +30 10 98 888 United Kingdom Knight Frank London +44 0 769 8171 cybarco.com
More informationAVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839
AVAILABLE TO DOWNLOAD ON THE APOLLO APP a guide to Fire Alarm Systems Design BS5839 Part1:2013 The Regulatory Reform (Fire Safety) Order (FSO) became law on 1 October 2006 Legally you must comply! What
More information48. AQUARIUM. Aquarium. Classification: Cluster: Location: Close to junction of Inselrhue and Loiter Way, Belle Isle. Total Area: No.
Classification: Cluster: Location: Total Area: No. of Stories Aquarium Acreage Owned: Acquired: 1904 Most Recent Improvements: THE AQUARIUM Close to junction of Inselrhue and Loiter Way, Belle Isle Two
More informationREFLEC TIONS I & II AT CIRCLEPORT
ERLANGER, KENTUCKY CL ASS A OFFICE SPACE AVAIL ABLE REFLECTIONS I & II AT CIRCLEPORT OFFERS MANY ADVANTAGES: State-of-the-art fiber optics cabling designed for New Economy as well as traditional business
More informationSCHEDULE OF FINISHES AMBLE RIDGE RETIREMENT VILLAGE
SCHEDULE OF FINISHES AMBLE RIDGE RETIREMENT VILLAGE SITEWORKS FOUNDATIONS & SURFACE BED Site to be cleared and leveled. Builder s rubble to be carted away. As per Engineer s design, with USB green waterproofing.
More informationFIRE RATED WIRING. What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager
FIRE RATED WIRING What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager INTRODUCTION OBC requirements for emergency power OBC requirements for emergency power for fire alarm systems and other building
More informationStandards. www.nordx.com 5 ANSI/TIA/EIA-569-A (CSA T530)
The primary focus of this standard is to provide design specifications and guidance for all building facilities relating to telecommunications cabling systems and components. This standard identifies and
More informationI. AMFITEATRU HOTEL ** For more details visit : http://www.unita-turism.ro/ro/sale-olimp-estival.html
NEPTUN OLIMP BLACK SEA RESORT SALE PRICE = 24.000.000 euro - Negociable price Amfiteatru** Belvedere**- Panoramic** Complex from Neptun-Olimp Resort has a total area of 44,308 square meters Olimp Resort
More informationLocation. Central Business District. Ataturk Airport IFC. Sabiha Gökçen Airport
Welcome Zenium Istanbul One provides 12,000 square metres of high specification technical space across three purpose-built data centers. It is Turkey s first wholesale data center offering; the data halls
More informationElva Business Centre Elva Way Bexhill on Sea East Sussex TN39 5BF DEVELOPMENT OF LIGHT INDUSTRIAL WORKSHOPS & OFFICE SPACE
With the support of Elva Business Centre Elva Way Bexhill on Sea East Sussex TN39 5BF DEVELOPMENT OF LIGHT INDUSTRIAL WORKSHOPS & OFFICE SPACE Viewing To view the units please contact the Estates Manager,
More informationCompliance Schedules and Building Warrant of Fitness
Compliance Schedules and Building Warrant of Fitness Purpose of this guidance information The purpose of this guidance information is to help building owners and managers of commercial, industrial or communal
More informationMEGAHUB LOGISTICS CENTER Center of Consumers. Hämeenlinna Lahti Turku Tampere
MEGAHUB LOGISTICS CENTER Center of Consumers Hämeenlinna Lahti Turku Tampere MegaHub Hämeenlinna Road connections E12 (Highway 3) Vuosaari 120 km Helsinki 100 km Highway 10 Turku 110 km Turku 100 km Jyväskylä
More informationGENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA)
GENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA) Chapter 1 : Definitions clause 1.2.10 : circulation space OLD CLAUSE A space mainly used as means of access between a room or protected shaft
More informationTechnical specifications. Containerized data centre NTR CDC 40f+
Technical specifications Containerized data centre NTR CDC 40f+ CONTENT 1 THE PURPOSE OF CDC... 3 2 BASIC PROPERTIES... 4 2.1 EXTERNAL DIMENSIONS... 4 2.2 INSTALLATION REQIREMENTS... 4 2.3 ELECTRICAL CONNECTION
More informationBUILDING PERMIT SPECIFICATIONS
BUILDING PERMIT SPECIFICATIONS The below noted requirements are based upon La Plata County Building Code. These specifications are not intended as a complete set of requirements, but are intended to provide
More informationHow To Set Up A Minipatch System For A Small Office Or Home Use
Issue : 4 Wood Communications Networking Products Catalogue Small Office & Home Solution Small Office / Home Solution Min LAN Comms Cabinets - Multimedia Panel - Soho Ethernet Switches - Multiroom Audio/Video,
More informationZone B: comprises of NOC room, reception area, Help Desk area, Call Centre, Testing/Monitoring room. This zone requires approximately 1500 sq. feet.
Annexure 1 Best practices and Guidelines to Physical Security of the State Data Centre The Data Centre should ideally be built in a central location within the building complex. An approximate area of
More informationPROPERTY FOR LEASE. 3 rd Floor Office Suite, Maxwell House, Armada Way, Plymouth PL1 1HZ
PROPERTY FOR LEASE 3 rd Floor Office Suite, Maxwell House, Armada Way, Plymouth PL1 1HZ Third storey office suite at junction of Mayflower Street and Armada Way Situated within Plymouth s shopping district
More informationA1.5 Classroom Standards
A1.5 Classroom Standards Note: The following standards have been developed and adopted by KU's Instructional and Mediated Spaces Committee (IMSAC), which includes representatives from DCM, Instructional
More informationBuilding Control Guidance Note
Issued 01/01/13 Rev Page 1 of 5 If you intend to convert an existing loft space into additional rooms you will need to apply for Building Regulation Approval. You may also need Planning Permission if you
More informationPrint Shop/Mail Room
Chapter XVIII Print Shop/Mail Room Page 110 CHAPTER XVIII Print Shop/Mail Room ARCHITECTURAL/STRUCTURAL A. BUILDING EXTERIOR 1.0 EXTERIOR WALLS The exterior walls are comprised of stone veneer. There were
More informationANNEX C - DESIGN BRIEF
ANNEX C - DESIGN BRIEF SCOPE OF WORKS 1.0 OBJECTIVE The Contractor undertakes the fit-out works in the area outlined in the layout plan, 2 nd Floor and new extension space on the 11 th Floor, at the EBRD
More informationREAL ESTATE DESCRIPTION
REAL ESTATE DESCRIPTION #51 SZIGETVÁR JÓZSEF ATTILA U. 27-31. Id. No.: 592 The Property Appraised Neighborhood Description The subject property is located in the center of the settlement of Szigetvár,
More informationOffice space for rent Poznań, 12-18 Murawa Street
Office space for rent Poznań, 12-18 Murawa Street Project description 1 Murawa Office Park stands out as the only such project in Poznań: the office complex consists of five elegant, low-rise modern buildings
More informationDATACENTER Vienna 1. Scalable, Safe and Innovative
DATACENTER Vienna 1 Scalable, Safe and Innovative Designed, built and optimized for the security of your data Contents Your Goals 2 Compound and Buildings 4 Energy Efficiency 6 Security 10 Infrastructure
More informationHamilton-Wentworth Catholic District School Board Event Listing By Ascending Event Year
Hamilton-Wentworth Catholic District School Board Event Listing By Ascending Event Year Printed On: 2003/04/03 St Patrick CES, 7932 Study [03.3-050 Plumbing Piping Systems] Study condition, remaining service
More informationMinimum Housing and Health Standards
APPENDIX M.O. 57/2012 Minimum Housing and Health Standards Original version July 20, 1999. Revisions to Part lll, Housing Premises, sections 3 and 4, June 30, 2012 (all revisions are bolded and underlined).
More informationCurrent as of 11/10/08 1 of 1
BEST PRACTICES STANDARDS FOR SCHOOLS UNDER CONSTRUCTION OR BEING PLANNED FOR CONSTRUCTION I. Site Layout A. School buildings shall be provided with a securable perimeter. A securable perimeter means that
More informationVALIANT OFFICE SUITES OFFICE SUITES LUMONICS HOUSE RUGBY. www.valiant-officesuites.co.uk
VALIANT OFFICE SUITES Suites ranging from 160 sq ft to 1500 sq ft LUMONICS HOUSE RUGBY Providing flexible, high quality, secure office space in Rugby with ample on site parking, 24 hour access together
More informationARE YOU WIRING FOR A SMART HOME? Guidelines for homeowners on the wiring requirements for telecommunications and other wired services.
ARE YOU WIRING FOR A SMART HOME? Guidelines for homeowners on the wiring requirements for telecommunications and other wired services. INTRODUCTION Installing the right wiring when building or renovating
More informationData Centre Stockholm II, Sweden Flexible, advanced and efficient by design.
Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design. Equinix Telecity Kvastvägen 25-29 128 62 Sköndal Stockholm Sweden Tel: +46 (0) 8 799 3800 se.info@telecity.com www.telecitygroup.se
More informationIBM Twin Data Center Complex Ehningen Peter John IBM BS peter.john@de.ibm.com. 2011 IBM Corporation
IBM Twin Data Center Complex Ehningen Peter John IBM BS peter.john@de.ibm.com Overview Profile IBM owned facility 6447 m² IT-Space Infrastructure concurrent maintainable (Tier Level 3) Feed-ins of Power
More informationBuilding Condition Assessment Report
Building Condition Assessment Report Asset C3c - Oak Terrace Cottage 121 Address Riverview Lands, 2601 Lougheed Highway, Coquitlam, BC. V5C 4J2 Construction Year Size (Gross Floor Area) 1920. 2,553 Sq.Ft.
More informationSaint Cloud Business Center
Saint Cloud Business Center 14 7th Avenue North Saint Cloud, MN 56303 For Sale Located on 7th Avenue in the heart of downtown across from the Court House Square. A large professional reception area with
More informationSchedule B to By-law 33-2009 Part A Fees Payable for Permits
Floor Area Calculation Floor area shall: Part A Fees Payable for Permits (Effective January 1, 2015) a) be calculated by measuring to the outer face of exterior walls and to the centre of party walls or
More informationHow To Build A Luxury Apartment Complex In London
Post Tensioning Awards 2009 Project Summary Type of structure Location Architects Structural Engineer Residential with leisure suites including Swimming pool, Cinema, Virtual Golf, Wine Cellars, and Parking
More informationponto trasso DESCRIPTION CHARACTERISTICS - FLOODLIGHTS ADVANTAGES VERSIONS
ponto trasso ponto trasso CHARACTERISTICS - FLOODLIGHTS Ponto Trasso Seal tightness: IP 67 (*) Impact resistance (glass): IK 10 (**) Static load resistance: 500 kg (*) Nominal voltage: 230 V AC Electrical
More informationPUBLIC RESTROOMS, DESIGN INTENT
PUBLIC RESTROOMS, DESIGN INTENT 1.01 STRUCTURAL A. Where feasible, metal stud partitions will be constructed on a 6 high concrete curb. 1.02 MECHANICAL A. Restrooms will have a minimum of 15 air changes
More informationSECTION 00 0110 TABLE OF CONTENTS. H. 00 2115.01 - Proposed Material, Product or Equipment Substitution Request
SECTION 00 0110 PROCUREMENT AND CONTRACTING REQUIREMENTS 1.1 DIVISION 00 -- PROCUREMENT AND CONTRACTING REQUIREMENTS A. 00 0101 - Project Title Page B. 00 0105 - Certifications Page C. 00 0110 - Table
More informationProperty Development
Property Development The Group will continue strengthening its reputation by enhancing the quality of its products and services and branding individual projects. High project marketability and improved
More informationBuckminster Yard. Easy-in, easy-out terms. 19TH CENTURY CHARM, 21ST CENTURY CHOICE. 11 self-contained serviced offices, from 400 to 1160 sq. ft.
N e w S E R V I C E D o f f i c e s t o r e n t. Easy-in, easy-out terms. self-contained serviced offices, from 00 to sq. ft. Fibre-optic broadband speeds - up to 0MB. Located between the towns of Melton
More informationRARE, PRECIOUS AND PRIVILEGED. LIFESTYLE LIKE A PEARL.
RARE, PRECIOUS AND PRIVILEGED. LIFESTYLE LIKE A PEARL. Open up to spectacular views, Open up to infinite sea, Live the life of your dreams, The way it has to be. Open up to elite lifestyle, Open up to
More information