IPSIP M series-m Modular Data Center

Size: px
Start display at page:

Download "IPSIP M series-m Modular Data Center"

Transcription

1 IPSIP M series-m Modular Data Center IPSIP MODULAR TECHNOLOGIES.

2 1

3 With the rapid development of cloud computing and mobile Internet businesses, the growth of IT density and energy consumption are bringing a lot, as well as improving the efficiency of data centers, accelerating the speed of deployment,and controlling investment and operating costs, IPSIP Modular has launched the M Series-M modular data center solution. M Series M is a new generation modular data center solution with complete integration of cabinets, power supply and distribution systems, cooling systems, cabling systems, management software, and much more. IPSIP Modular M Series-M modular data center adopts All-in-room integration design. It supports flexible deployment with single or dual row, contained or non-contained aisle, cold or hot aisle containment. Maximum 48 cabinets can be deployed in dual-row module and 18 cabinets in single-row module with 3~36 IT cabinets. The maximal IT power can be up to 21kW/ rack. Single module is suitable for the space below 100m2.. M Series-M module data center has been widely applied in small and medium enterprises as well as the branch of large corporation in government,education, healthcare, finance industry etc, and medium capacity desktop cloud computing and high-performance computing data center. Customer Value: Fast deployment All in room design, a single room integrates cabinets, confined aisle, power supply and distribution system, cooling system and management system. Factory prefabrication and standardized interfaces makes installation within 1 week and deployed period saving up to 50% High adaptability Maximizing the space utilization by flexible deployment of single-row or dual-row for diversified rooms Support concrete floor or raise height floor installation, only a 2.6 m net height is required Efficient & modular design Modular structure makes scalable expansion and Capex saving up to 30% Associate with In-row cooling, modular UPS, aisle containment and highly integrated PDU cause the PUE lower than 1.5 Intelligent management IPSIP Modular NetEco management system can monitor all data center facility uniformly including electricity, environment, video, access control etc The comprehensive intelligent management platform provides functions such as alarm management, report management, capacity management, energy efficiency management, resource management, 3D view realizes precise management, simple operation and maintenance and energy saving 2

4 Two types of cable troughs: signal cable troughs and power cable troughs. Cables insulation reduces system interference and increase reliability. Cable holes are located in the center of each cabinet top cover to simplify cable-routing into the cabinet. The expansion of length direction can be achieved. Cabling Skylight A flat roof ceiling consists of side panels, top frames, and revolving ceiling panels. The temperature detector and smoke alarm are installed in containment aisle, and are linked with skylight controller. After the action of electromagnetic switch, the rotate skylight automatically opens by gravity, ensuring the fire extinguishing gases into the aisle. End door The end door of a confined channel can be a sliding door or a double door. Tempered glass is used as the door panel, which ensures channel visibility and meets fire fighting requirements. Sealed brushes are installed at the bottom of the door panel, making the date center module sealed in an enhanced manner. The access control system is optional when a double door is used. Power system Power Distribution - PDF PDF includes integrated PDF and combined PDF (UPS PDF and precise PDF). 380/400/415V (3Ph, 50/60Hz) are all supported. UPS PDF integrated ATS, UPS power supply and air conditioner power supply, and precise PDF mainly provides power and energy measurement for IT load. Power Supply - UPS The UPS provides an uninterruptible power supply for the modular data center. 380/400/415V (3Ph, 50/60Hz) are all supported. According to Tier II, Tier III, Tier IV demands, power supply system is in the N, N+1, 2N backup. 3

5 NetEco system NetEco system manages the real-time data and status of data center infrasturctures, including power, environment, video, and door status. Handling emer gencies automatically, impr oving management efficiency greatly, reducing the cost of O&M. Dynamic PUE management, optimizing important power and cooling services, smart interaction with cloud-platform. Fire system FM200 heptafluoropropane gas is equipped, module containment is installed with smoke temperature sensors, when the smoke sensor and temperature sensor are warning at the same time, then the fire control system push gas into module; External smoke sensor, and temperature sensor fixing bracket are available, and the height is adjustable to realize fast free-engineering (when not using the fixing bracket, sensors can be directly installed on the ceiling). Cooling In a modular data center, air conditioners and racks form cold /hot aisles for isolation between cold air and hot air. Row-level ACs are close to the heat sources, which reduces the air pressure losses and minimizes cold air leakage to maximize the use of cold air. The cooling supply system is in the 'N+X' backup, which complies 'Tier III', and for higher reliability, the 'Tier IV' could be also customized. Rack One modular data center consists of 48 server racks at most. Racks are unified in dimension, and complied with 19-inch standard, and the air ventilation is front-to-rear, and the doors' perforation rate is 67%. Super bearing load: static load is1200 kg. All racks are pre-installed in factory, which make on-site implementation much faster. 4

6 IDS2000-M Specifications Item Specifications 300mm single-row with aisle containment: L x 1560mm x 2180mm, L 10800mm 1200mm single-row with aisle containment: L x 2400mm x 2350mm, L 10800mm Number of IT racks per module Single row: 12; dual row 36 Dual-row with aisle containment: L x 3600mm x 2350mm, L 14400mm System Input Power IT Power Consumption Maximum power per rack Operating Condition Reliability level 208/220V (3Ph, 60Hz) 380/400/415V (3Ph, 50/60Hz) 440/460/480V (3Ph, 60Hz) 208V: 15~75kVA 380V: 10~200kVA 480V: 80/120kVA 21kW T1 condition: 30ºC ~ +45ºC; T3 condition: 20ºC ~ +55ºC Tier II or Tier III (up to Tier IV) Altitude 0 ~ 1000m (derating above 1000m) Cabinet Air-cooled In-row Air Conditioner Chilled water In-row Air Conditioner Rack-mounted UPS Modular UPS Installation (H x W x D) Installation space Protection level Cooling capacity (H x W x D) Input power Refrigerant Cooling capacity (H x W x D) Input power Refrigerant Input power Rated capacity Input power Rated capacity Installing on concrete floor or raised floor 2000mm x 600mm x 1200mm/2200mm x 600mm x 1200mm 42U/47U IP20 25kW/35kW 2000mm x 600mm x 1100mm 380/400/415V (3Ph, 50/60Hz),440/460/480V (3Ph, 60Hz) R410A 30kW 2000mm x 300mm x 1200mm 200~240V (1Ph, 50/60Hz) Water / Ethylene Glycol 380V (3Ph, 50/60Hz) 10/15/20kVA 380V (3Ph, 50/60Hz) 40/80/120/160/200kVA 5

7 IPSIP Modular NetHos cabinet NetHos series cabinet which is reliable, safe, compatible and environment-friendly, meets different scenarios of modular data centers. Safety and reliability Complied with IEC standard, adjustable distance between the front and the rear mounting bars Stable Structure Design Super bearing load: static load is1200 kg Good heat dissipation The doors' perforation rate is 67%, to ensure the smooth air ventilation Good compatibility Standardized design, compatible with different 19-inch equipment Flexible expansion Using connection fittings, to support cabinets mounted side by side Professional power distribution solutions Professional cabinet-level power system, providing various types of power distribution solutions A two-section side panels The side panels are fixed with tools, easy for installation, transportation and disassembly Perfect cable management Top or bottom wiring is optional with cable through on top Division Design On-demand deployment for different businesses and different densities 6

8 IPSIP Modular UPS series UPS2000-G series (1/3/6/10/15/20kVA) UPS5000-E series (40/80/120/160/200/240/280/320kVA) UPS5000-A series (30/40/60/80/120/200/300/400/500/600/800kVA) UPS8000-D series (200/300/400/500/600kVA) Reliable Efficient Convenient Intelligent A strong know-how support system to safeguard up to 1,000,000+ IPSIP Modular power system under the harsh and severe environments Tests performed under the extreme environment conditions, i.e. Airborne Hygroscopic Dust Test(AHD) and Long Life Test(LLT) The key components used are provided by Top 3 suppliers High efficiency at online mode: up to 96% High efficiency at low load rate enables IPSIP Modular UPS to reduce power loss even at parallel configuration Globally, IPSIP Modular UPS has achieved Energy Star qualification in the first batch Modularization, ease of expansion Standardization, ease of identification Integration, ease of delivery Fault-tolerant, ease of maintenance A built-in real-time operating system offers reliability and flexibility Real-time monitoring on battery parameter and automatic temperature compensation NetEco smart network to cover all power supply nodes 7

9 IPSIP Modular precision air conditioner series NetCol5000-A series Air-cooled in-row precision air conditioner (25/35kW) NetCol5000-C series Chilled-water in-row precision air conditioner (30kW) NetCol8000-A series Air-cooled in-room precision air conditioner (50/100kW) NetCol8000-C series Chilled-water in-room precision air conditioner (50/70/120/150kW) Efficient Reliable Intelligent Green Component-level energy saving: Integrated high efficiency DC inverter compressor, EC fan, power supply module etc Unite-level energy saving: CFD simulation, field synergy design, optimized matching System level saving: Function such as cascading, rotation and operation mode of avoiding competition Key component are in redundancy design Wide operating temperature range: -20ºC ~ +55ºC Lightning filtering board designs, adapts for extreme mains CAN communication protocol realizes accurate control of air conditioner s parameters Linkage and group control function can control up to 32 air conditioners One-key fault information collection, clearly display fault reason and maintenance strategy R410A environment friendly refrigerant with high efficiency RoHS complied 8

10 M Series-M Typical Products 20KVA M020-4D-4 UPS capacity 20kVA Number of IT racks 4 Power density 4kW/R 3.6m 3m M020-4S-4 UPS capacity 20kVA Number of IT racks 4 Power density 4kW/R 1.5m 6m M020-5D-3 UPS capacity 20kVA Number of IT racks 5 Power density 3kW/R 3.6m 3.6m M020-5S-3 UPS capacity 20kVA Number of IT racks 5 Power density 3kW//R 1.5m 6.6m Note: M020-4D-4: M: modular data centers; -: hyphen; 020: main UPS capacity 20kVA; 4: number of IT racks; D: single or dual row (D: dual-row aisle; S: single-row aisle); 4: IT power per rack is 4kW 9

11 M Series-M Typical Products 30KVA M030-6D-4 UPS capacity 30kVA Number of IT racks 6 Power density 4kW/R Backup time 40min 3.6m 3.6m M030-6S-4 UPS capacity 30kVA Number of IT racks 6 Power density 4kW/R Backup time 40min 1.5m 7.2m M030-8D-3 UPS capacity 30kVA Number of IT racks 8 Power density 3kW/R Backup time 40min 3.6m 4.2m M030-8S-3 UPS capacity 30kVA Number of IT racks 8 Power density 3kW/R Backup time 40min 1.5m 8.4m 10

12 M Series-M Typical Products 40KVA and 60KVA M040-5D-5 UPS capacity 40kVA Number of IT racks 5 Power density 5kW/R 3.6m 3.6m M040-5S-5 UPS capacity 40kVA Number of IT racks 5 Power density 5kW/R 1.5m 7.2m M040-8D-4 UPS capacity 40kVA Number of IT racks 8 Power density 4kW/R 3.6m 4.8m M060-8D-5 UPS capacity 60kVA Number of IT racks 8 Power density 5kW/R 3.6m 5.4m 11

13 M Series-M Typical Products 80KVA and 120KVA M080-11D-5 UPS capacity 80kVA Number of IT racks 11 Power density 5kW/R Backup time 15min 3.6m 6m M080-7D-9 UPS capacity 80kVA Number of IT racks 7 Power density 9kW/R Backup time 15min 3.6m 4.8m Note: The dimensions do not include external power area M120-10D-9 UPS capacity 120kVA Number of IT racks 10 Power density 9kW/R 3.6m 5.4m Note: The dimensions do not include external power area M120-17D-5 UPS capacity 120kVA Number of IT racks 17 Power density 5kW/R 3.6m 7.2m 12

Huawei IDS2000 Modular Data Center Solution

Huawei IDS2000 Modular Data Center Solution CloudPower Huawei IDS2000 Modular Data Center Solution HUAWEI TECHNOLOGIES CO., LTD. With the rapid development of cloud computing and mobile Internet businesses, the growth of IT density and energy consumption

More information

Huawei IDS1000 Container Data Center Solution

Huawei IDS1000 Container Data Center Solution CloudPower Huawei IDS1000 Container Data Center Solution HUAWEI TECHNOLOGIES CO., LTD. Traditional data centers suffer from long construction periods, high energy consumption and high initial investment,

More information

HUAWEI TECHNOLOGIES CO., LTD. Huawei IDS2000-S Small Modular Data Center Solution

HUAWEI TECHNOLOGIES CO., LTD. Huawei IDS2000-S Small Modular Data Center Solution HUAWEI TECHNOLOGIES CO., LTD. Huawei IDS2000-S Small Modular Data Center Solution Group Data Center Concept: big center, small branch With the development and maturity of the IT automation age, rapid development

More information

High-density modular data center making cloud easier. Frank Zheng Huawei

High-density modular data center making cloud easier. Frank Zheng Huawei High-density modular data center making cloud easier Frank Zheng Huawei 2012-10-10 Content 1 2 3 4 Cloud s impact to data center Concerns of DC construction 4S DC making cloud easier Success stories Cloud?

More information

JAWAHARLAL NEHRU UNIVERSITY

JAWAHARLAL NEHRU UNIVERSITY School of Biotechnology JAWAHARLAL NEHRU UNIVERSITY New Delhi 110 067 Tender No. JNU/SBT/DBT-BUILDER/Data Centre/2015-16 Sealed Quotation for the establishment of a Data Centre for High-End Computational

More information

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America 7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer

More information

RiMatrix S Make easy.

RiMatrix S Make easy. RiMatrix S Make easy. 2 RiMatrix S Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power

More information

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER Your Complete Turnkey Server Room Air Condition UPS THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER AVAILABLE IN WATER AND GAS SYSTEM MODEL AIR-CONDITIONED CABINET EXCELLENT TEMPERATURE CONTROL FOR

More information

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management. AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled

More information

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing

More information

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while

More information

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009 Optimum Climate Control For Datacenter - Case Study T. Prabu March 17 th 2009 Agenda 2 About EDEC (Emerson) Facility Data Center Details Design Considerations & Challenges Layout Design CFD Analysis Of

More information

How To Build A T7 Rack For Information Technology

How To Build A T7 Rack For Information Technology THE NEXT GENERATION RACK FOR INFORMATION TECHNOLOGY THE RACK CABINET FOR INFORMATION TECHNOLOGY T7, THE HI-TECH HEART OF THE BLADESHELTER SYSTEM The real answer to the requirements of: Safety Versatility

More information

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions Data Centre Solutions... energy efficient by design APC by Schneider Electric Elite Data Centre Partner APC s leading Elite Data Centre Solutions Partner providing customers with expert advice, integration

More information

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management. AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled

More information

Huawei Data Center Facility Integration Solution

Huawei Data Center Facility Integration Solution Huawei Data Center Facility Integration Solution HUAWEI TECHNOLOGIES CO., LTD. As the growing demand for efficiency, flexibility and low-cost, enterprise need a more flexible and efficient data center

More information

Technical specifications. Containerized data centre NTR CDC 40f+

Technical specifications. Containerized data centre NTR CDC 40f+ Technical specifications Containerized data centre NTR CDC 40f+ CONTENT 1 THE PURPOSE OF CDC... 3 2 BASIC PROPERTIES... 4 2.1 EXTERNAL DIMENSIONS... 4 2.2 INSTALLATION REQIREMENTS... 4 2.3 ELECTRICAL CONNECTION

More information

Scalable. Affordable. Flexible. Fast.

Scalable. Affordable. Flexible. Fast. Modular Data Center Solutions Scalable. Affordable. Flexible. Fast. Build the data center you need today with the flexibility to meet tomorrow s challenges The only constant in business is change. Fluctuations

More information

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity Liebert Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment Precision Cooling For Business-Critical Continuity The Intelligent Data Center Cooling Solution: Liebert Trust the industry

More information

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management. AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled

More information

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Dealing with Thermal Issues in Data Center Universal Aisle Containment Dealing with Thermal Issues in Data Center Universal Aisle Containment Daniele Tordin BICSI RCDD Technical System Engineer - Panduit Europe Daniele.Tordin@Panduit.com AGENDA Business Drivers Challenges

More information

Managing Data Centre Heat Issues

Managing Data Centre Heat Issues Managing Data Centre Heat Issues Victor Banuelos Field Applications Engineer Chatsworth Products, Inc. 2010 Managing Data Centre Heat Issues Thermal trends in the data centre Hot Aisle / Cold Aisle design

More information

Huawei Cloud and Virtualization introduction HUAWEI TECHNOLOGIES CO., LTD.

Huawei Cloud and Virtualization introduction HUAWEI TECHNOLOGIES CO., LTD. Huawei Cloud and Virtualization introduction HUAWEI TECHNOLOGIES CO., LTD. Lode pokladu admirala Zheng He Huawei Desktop Cloud E2E Solution Architecture Cloud Network Terminal Desktop managemen t FusionAccess

More information

System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution

System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution System integration oriented data center planning In terms of ATEN's eco Sensors DCIM solution 1. Introduction The reliability of an enterprise data center servicing either external or internal clients

More information

Data Center Solutions - The Containerized Evolution

Data Center Solutions - The Containerized Evolution Data Center Solutions - The Containerized Evolution Power IT Cooling 7 th Green Connected World Tsikogias Thanassis Data Centers Solutions Architect, IT Business Athens 2015 1 We are the global specialist

More information

APC APPLICATION NOTE #112

APC APPLICATION NOTE #112 #112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.

More information

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS Air / Water / DX Cooled Cabinet Solutions Mini Data Centre All in One Solution: Where there is a requirement for standalone computing and communications, or highly

More information

Eaton 93PM UPS Where aesthetics meet intelligence.

Eaton 93PM UPS Where aesthetics meet intelligence. Brochure 100 kw Eaton 93PM UPS Where aesthetics meet intelligence. 93PM features and benefits The Eaton 93PM UPS combines unprecedented and reliability with eye-catching design. A space-saving, flexible

More information

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert Data Center Consolidation Trends & Solutions Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert Agenda Traditional Data Centers Drivers of a Changing Environment Alternate

More information

IBM Twin Data Center Complex Ehningen Peter John IBM BS peter.john@de.ibm.com. 2011 IBM Corporation

IBM Twin Data Center Complex Ehningen Peter John IBM BS peter.john@de.ibm.com. 2011 IBM Corporation IBM Twin Data Center Complex Ehningen Peter John IBM BS peter.john@de.ibm.com Overview Profile IBM owned facility 6447 m² IT-Space Infrastructure concurrent maintainable (Tier Level 3) Feed-ins of Power

More information

Data Center Components Overview

Data Center Components Overview Data Center Components Overview Power Power Outside Transformer Takes grid power and transforms it from 113KV to 480V Utility (grid) power Supply of high voltage power to the Data Center Electrical Room

More information

THE WORLD S MOST EFFICIENT DATA CENTER

THE WORLD S MOST EFFICIENT DATA CENTER THE WORLD S MOST EFFICIENT DATA CENTER HP POD 240a Ed Turkel Manager, WW HPC Marketing Hyperscale Business Unit 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject

More information

In Row Cooling Options for High Density IT Applications

In Row Cooling Options for High Density IT Applications In Row Cooling Options for High Density IT Applications By Ramzi Y. Namek, PE, LEED AP, BD+C; Director of Engineering 1 Users wishing to deploy high density IT racks have several In Row Cooling solutions

More information

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment The Intelligent Data Center Cooling Solution: Liebert CRV Trust the industry leader in Precision Cooling to deliver

More information

Automation's Modular Containerized Datacenter Solutions

Automation's Modular Containerized Datacenter Solutions SAFE Automation's Modular Containerized Datacenter Solutions Automation's SAFE (Secure, Autonomous, Flexible, Efficient) Modular Containerized Datacenter offers a fast, flexible and efficient solution

More information

Portable Energy Efficient Data Centre Solution

Portable Energy Efficient Data Centre Solution Portable Energy Efficient Data Centre Solution Workspace Technology Limited Technology House, PO BOX 11578, Sutton Coldfield West Midlands B72 1ZB Telephone: 0121 354 4894 Facsimile: 0121 354 6447 www.workspace-technology.com

More information

Questions to be responded to by the firm submitting the application. Why do you think this project should receive an award? How does it demonstrate:

Questions to be responded to by the firm submitting the application. Why do you think this project should receive an award? How does it demonstrate: Questions to be responded to by the firm submitting the application Why do you think this project should receive an award? How does it demonstrate: innovation, quality, and professional excellence transparency

More information

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

Reference Guide: SmartDesign Approach: Common Data Center Challenges: Smart Solutions Reference Guide Solutions For Business-Critical Continuity 1100kW Tier 3 With High Density Design Intelligent, Integrated Infrastructure for the Data Center Reference Guide: 1100kW Tier

More information

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms Agenda Review of cooling challenge and strategies Solutions to deal with wiring closet cooling Opportunity and value Power

More information

All-in-one Container Data Center solution HUAWEI TECHNOLOGIES CO., LTD.

All-in-one Container Data Center solution HUAWEI TECHNOLOGIES CO., LTD. All-in-one Container Data Center solution Contents All-in-one : Integrated one-stop data center solution All-in-one configuration and subsystems introduction Application scenarios and successful stories

More information

CoolTeg Plus Chilled Water (CW) version: AC-TCW

CoolTeg Plus Chilled Water (CW) version: AC-TCW version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420

More information

Choosing Close-Coupled IT Cooling Solutions

Choosing Close-Coupled IT Cooling Solutions W H I T E P A P E R Choosing Close-Coupled IT Cooling Solutions Smart Strategies for Small to Mid-Size Data Centers Executive Summary As high-density IT equipment becomes the new normal, the amount of

More information

Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION

Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION The heat load in data centers is increasing rapidly, the adaptation of a cooling strategy is often necessary. Many data centers and server rooms use

More information

How To Upgrade An Hp Power Distribution Rack To A Power Distribution Unit

How To Upgrade An Hp Power Distribution Rack To A Power Distribution Unit Overview Power protection in the data center is critical to maintain up time, and the increased densities in data centers is driving the need for uninterruptible power with increased power density, power

More information

AIRAH Presentation April 30 th 2014

AIRAH Presentation April 30 th 2014 Data Centre Cooling Strategies The Changing Landscape.. AIRAH Presentation April 30 th 2014 More Connections. More Devices. High Expectations 2 State of the Data Center, Emerson Network Power Redefining

More information

NAISSUS THERMAL MANAGEMENT SOLUTIONS

NAISSUS THERMAL MANAGEMENT SOLUTIONS NAISSUS THERMAL MANAGEMENT SOLUTIONS HIGH PERFORMANCE CLOSED LOOP WATER COOLING SYSTEM NTMS30 30kW SYSTEM Cool the servers, not the room! NAISSUS THERMAL MANAGEMENT SOLUTIONS HIGH PERFORMANCE CLOSED LOOP

More information

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity Modular architecture for high power UPS systems A White Paper from the experts in Business-Critical Continuity Abstract Today, more than ever before, energy efficiency and cost-savings are among the top

More information

30-120 3 Phase Modular Finally the benefits of Modular ups are for all

30-120 3 Phase Modular Finally the benefits of Modular ups are for all MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion

More information

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity SmartDesign Intelligent, Integrated Infrastructure For The Data Center Solutions For Business-Critical Continuity Prepare Your Data Center For What s Next Efficiency. Availability. Capacity. Control. One

More information

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA - 12859 North America Version 5 August 22, 2008 Page 1

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA - 12859 North America Version 5 August 22, 2008 Page 1 Overview It's getting harder to manage a data center efficiently, with rising utility bills and ever-increasing demands due to processor power and server density increases. Growing user requests mean heavier

More information

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels

More information

APC APPLICATION NOTE #92

APC APPLICATION NOTE #92 #92 Best Practices for Designing Data Centers with the InfraStruXure InRow RC By John Niemann Abstract The InfraStruXure InRow RC is designed to provide cooling at the row and rack level of a data center

More information

Data Centre Testing and Commissioning

Data Centre Testing and Commissioning Data Centre Testing and Commissioning What is Testing and Commissioning? Commissioning provides a systematic and rigorous set of tests tailored to suit the specific design. It is a process designed to

More information

POD S in Data Centres. The Frame Group Pty Ltd

POD S in Data Centres. The Frame Group Pty Ltd Presented by: Greg Goode The Frame Group Pty Ltd DATA Centres? POD SOLUTIONS REFERRED TO AS: Cells Modular Rooms High Density Zones Portable Modular Data Centres (Containers) Multiple Interpretations Varied

More information

CANNON T4 MODULAR DATA CENTRE HALLS

CANNON T4 MODULAR DATA CENTRE HALLS CANNON T4 MODULAR DATA CENTRE HALLS Halve up-front investment, use a Modular fit out approach Highly efficient, Low PUE, Scalable system with reduced Capex and Opex Turnkey solutions available complete,

More information

DIGITUS Network & Server Cabinets. UNIQUE Series

DIGITUS Network & Server Cabinets. UNIQUE Series DIGITUS Network & Server Cabinets UNIQUE Series Benefits - Server Rack 4-Point locking system front door 3-point locking system rear door Swing handle lock with profile zylinder in front and rear door

More information

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings

More information

INFRASTRUCTURE FOR DATACENTERS

INFRASTRUCTURE FOR DATACENTERS INFRASTRUCTURE FOR DATACENTERS 02 ENERGY EFFICIENCY IN DATACENTERS The energy efficiency is one of the biggest challenges that datacenter infrastructures are facing today. The datacenters need to have

More information

Upgrading the PRS datacentres: space requirement. S. S. Mathur, GM-IT, CRIS

Upgrading the PRS datacentres: space requirement. S. S. Mathur, GM-IT, CRIS Upgrading the PRS datacentres: space requirement S. S. Mathur, GM-IT, CRIS PRS / UTS scenario: then and now Year 2000 PRS: 600 locations UTS: 0 locations Year 2008 PRS 1600 locations E-ticketing Passengers

More information

About Injazat. Enterprise Cloud Services. Premier Data Center. IT Outsourcing. Learning and Development Services. Enterprise Application Services

About Injazat. Enterprise Cloud Services. Premier Data Center. IT Outsourcing. Learning and Development Services. Enterprise Application Services About Injazat Injazat Data Systems is an industry-recognized market leader in the region for Information Technology Outsourcing, Cloud and Data Center Managed Services delivered from the region s 1st Tier

More information

This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits.

This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits. This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits. DCD, DCOM, DCE DESIGN IMPLEMENTATION BEST PRACTICE OPERATION & MANAGEMENT DATA

More information

EHDC. Cooling system for Data Center and server cabinets.

EHDC. Cooling system for Data Center and server cabinets. EHDC Cooling system for Data Center and server cabinets. EHDC PEN LP EHDC L is a High Density Cooling module for an pen Loop configuration. It is ideally installed with Enoc Systems cold corridor containment

More information

The Pros and Cons of Modular Systems

The Pros and Cons of Modular Systems The Pros and Cons of Modular Systems Kevin Brown, Vice President Global Data Center Offer Schneider Electric Schneider Electric 1 Foundational BUSINESS OVERVIEW Rev 2 Desired characteristics of pre-fabricated

More information

White Paper Rack climate control in data centres

White Paper Rack climate control in data centres White Paper Rack climate control in data centres Contents Contents...2 List of illustrations... 3 Executive summary...4 Introduction...5 Objectives and requirements...6 Room climate control with the CRAC

More information

As close to perfection. development and production. Modular data center

As close to perfection. development and production. Modular data center As close to perfection development and production Modular data center August 2014 What is GreenMDC modular data center? Basically it is the modular design construction which is realized by the principle

More information

SERVER ROOM CABINET INSTALLATION CONCEPTS

SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS ZPAS 169 EXAMPLES OF SERVER ROOMS PROJECTS WITH ZPAS CABINETS Data Box in the

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

Energy Efficiency and Availability Management in Consolidated Data Centers

Energy Efficiency and Availability Management in Consolidated Data Centers Energy Efficiency and Availability Management in Consolidated Data Centers Abstract The Federal Data Center Consolidation Initiative (FDCCI) was driven by the recognition that growth in the number of Federal

More information

COMPARISON OF EFFICIENCY AND COSTS BETWEEN THREE CONCEPTS FOR DATA-CENTRE HEAT DISSIPATION

COMPARISON OF EFFICIENCY AND COSTS BETWEEN THREE CONCEPTS FOR DATA-CENTRE HEAT DISSIPATION COMPARISON OF EFFICIENCY AND COSTS BETWEEN THREE CONCEPTS FOR DATA-CENTRE HEAT DISSIPATION 1/16 Contents: 1. Introduction: the increasing importance of energy efficiency 1.1 Power consumers in the data

More information

Cisco Nexus 7000 Series Power Supply Modules

Cisco Nexus 7000 Series Power Supply Modules Cisco Nexus 7000 Series Power Supply Modules Product Overview The Cisco Nexus 7000 Series Power Supply Modules (Figures 1 and 2) deliver fault tolerance, high efficiency, load sharing, and hot-swappable

More information

opdc Cut your data center OPEX upto 70%

opdc Cut your data center OPEX upto 70% opdc Cut your data center OPEX upto 70% Advantages Configuration Introducing the plug & play On Premises Data Center Introducing - The plug & play on premises data center The is a self-contained data center

More information

Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime

Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime Containerized Infrastructure for Business-Critical Continuity Are you deploying a remote site faster than you can

More information

BRUNS-PAK Presents MARK S. EVANKO, Principal

BRUNS-PAK Presents MARK S. EVANKO, Principal BRUNS-PAK Presents MARK S. EVANKO, Principal Data Centers of the Future and the Impact of High Density Computing on Facility Infrastructures - Trends, Air-Flow, Green/LEED, Cost, and Schedule Considerations

More information

Colt Colocation Services. 2010 Colt Technology Services Group Limited. All rights reserved.

Colt Colocation Services. 2010 Colt Technology Services Group Limited. All rights reserved. Colt Colocation Services 2010 Colt Technology Services Group Limited. All rights reserved. Award winning Colt Data Centre Solutions 2012: Modular Data Centre Solution of the year winner at 5 th Datacentre

More information

Case Study: Guaranteed efficiency through standardised data centres

Case Study: Guaranteed efficiency through standardised data centres Case Study: Guaranteed efficiency through standardised data centres Rittal / SEC Event / October 2014 1 Case Study: Guaranteed efficiency through standardised data centres Smart Energy Community Event

More information

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings WH I TE PAPE R AisleLok Modular Containment vs. : A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings By Bruce Long, Upsite Technologies, Inc. Lars Strong, P.E., Upsite Technologies,

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009 Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009 Agenda Overview - Network Critical Physical Infrastructure Cooling issues in the Server Room

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

Airflow Simulation Solves Data Centre Cooling Problem

Airflow Simulation Solves Data Centre Cooling Problem Airflow Simulation Solves Data Centre Cooling Problem The owner s initial design for a data centre in China utilized 40 equipment racks filled with blade servers spread out in three rows along the length

More information

AIR-SITE GROUP. White Paper. Green Equipment Room Practices

AIR-SITE GROUP. White Paper. Green Equipment Room Practices AIR-SITE GROUP White Paper Green Equipment Room Practices www.air-site.com Common practices to build a green equipment room 1 Introduction Air-Site (www.air-site.com) is a leading international provider

More information

Liebert APM from 30-150 kw. The Compact Row-Based UPS With FlexPower Technology TM

Liebert APM from 30-150 kw. The Compact Row-Based UPS With FlexPower Technology TM Liebert APM from 30-150 kw The Compact Row-Based UPS With FlexPower Technology TM Emerson Network Power, a division of Emerson, is a global company that combines technology with design to supply innovative

More information

PowerGem Pro Uninterruptible Power Supply

PowerGem Pro Uninterruptible Power Supply Uninterruptible Power Supply User-friendly Intelligent Ultra reliable Range The Most Intelligent On-Line Double Conversion Power Protection System The range achieves higher reliability and greater immunity

More information

AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass APC AIS 3000, 12 kw / 15 kva,input 208V 3PH / Output 120V, 208V, 208V 3PH, Interface Port DB-9 RS-232,

More information

The Mission Critical Data Center Understand Complexity Improve Performance

The Mission Critical Data Center Understand Complexity Improve Performance The Mission Critical Data Center Understand Complexity Improve Performance Communications Technology Forum Fall 2013 Department / Presenter / Date 1 Rittal IT Solutions The State of the Data Center Market

More information

DataCenter 2020: first results for energy-optimization at existing data centers

DataCenter 2020: first results for energy-optimization at existing data centers DataCenter : first results for energy-optimization at existing data centers July Powered by WHITE PAPER: DataCenter DataCenter : first results for energy-optimization at existing data centers Introduction

More information

SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU5000RT4UHV Description Tripp Lite SU5000RT4UHV 5000VA / 5kVA /

More information

FULL DC INVERTER SYSTEMS

FULL DC INVERTER SYSTEMS FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation

More information

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Scale-Out Smart for HPC, Cloud and Hyper-Converged Computing

More information

Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001

Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001 Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001 Presented by: Liberty Engineering, LLP 1609 Connecticut Avenue

More information

Cisco Redundant Power System 2300

Cisco Redundant Power System 2300 Cisco Redundant Power System 2300 The Cisco Redundant Power System 2300 (RPS 2300) increases availability for converged data, voice, and video networks. The system delivers power supply redundancy and

More information

Rittal Liquid Cooling Series

Rittal Liquid Cooling Series Rittal Liquid Cooling Series by Herb Villa White Paper 04 Copyright 2006 All rights reserved. Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Phone +49(0)2772 / 505-0 Fax +49(0)2772/505-2319 www.rittal.de

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw Knürr DCL Modular Rack Cooling from 6 kw to 60 kw Emerson Network Power Business-Critical Continuity so your success continues! Core competencies AC Power Connectivity DC Power Embedded Computing Embedded

More information

How to Meet 24 by Forever Cooling Demands of your Data Center

How to Meet 24 by Forever Cooling Demands of your Data Center W h i t e P a p e r How to Meet 24 by Forever Cooling Demands of your Data Center Three critical aspects that are important to the operation of computer facilities are matching IT expectations with the

More information

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

Energy Efficiency Best Practice Guide Data Centre and IT Facilities 2 Energy Efficiency Best Practice Guide Data Centre and IT Facilities Best Practice Guide Pumping Systems Contents Medium-sized data centres energy efficiency 3 1 Introduction 4 2 The business benefits

More information

Building a data center. C R Srinivasan Tata Communications

Building a data center. C R Srinivasan Tata Communications Building a data center C R Srinivasan Tata Communications Introduction Data Center as defined by TIA 942 A building or a portion of a building whose primary function is to house a computer room and its

More information

AU-110 racking guide NBXPN: 023

AU-110 racking guide NBXPN: 023 AU-110 racking guide NBXPN: 023 1. Overview NIMBOXX AU-110 Rack Installation This guide provides setup instructions for installing your NIMBOXX AU-110 in a rack. Following these steps in the order given

More information

Galaxy VM. Three-phase power protection. schneider-electric.com

Galaxy VM. Three-phase power protection. schneider-electric.com Galaxy VM Three-phase power protection schneider-electric.com 2 schneider-electric.com schneider-electric.com 3 Galaxy VM trusted partner for your business continuity Features and benefits Highly efficient,

More information

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,

More information