CREATING LOCKING SOLUTIONS...



Similar documents
Shunt lock function 3066




Technical Information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

ABLOY EXIT. Functional and technical descriptions Single and double leaf doors. An ASSA ABLOY Group brand

Cable Plug acc. to DIN EN , Form A

Digital Keypad Use s Manual

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Combi B Alarm box. Mounting instructions

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Adaptability to Enhanced Security

Adaptability to Enhanced Security

Electro-Pneumatic Bus Door Control Mechanism

Mureva Assembly surface mounted wiring devices

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Adjustment functions for both span and shift have been incorporated

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

OPL BASIC. Dosing System for Professional Laundry machines. Contents

AC-115 Compact Networked Single Door Controller. Installation and User Manual

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Magnetic proximity switches

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Neo-Neon. LED Vision Mesh Screen Operation Manual. LED Vision Mesh Screen. Neo-Neon International Ltd He Shan Decorative Lighting Company Limited

PHA 2000 PHB 3000 EXIT PAD

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

ABLOY EL460, EL461, EL560, EL561 Europrofile handle controlled locks

HERZ-Thermal Actuators

YALE DIGITAL DEADBOLT

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

Series 7500 Torque Sensor

TT 49 MICROPROCESSOR-BASED DIGITAL ELECTRONIC TIMER. OPERATING INSTRUCTIONS Vr. 01 (ENG) - cod.: ISTR TECNOLOGIC S.p.A.

Power Socket (2 Gang)

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

INSTALLATION MANUAL XM3 Reader

COMPALARM AP GENERAL MAIN FEATURES

How To Use A Flowmeter

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

2013 Wireless Video Intercom INSTALLATION GUIDE

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Product and functional description

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Broadway 3D Security System

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

EQUIPMENT SPECIFICATIONS

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Wespot. SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Installation & User Manual Radio Remote rev1.0.3

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Electronic Pressure Switch EDS 300

USER MANUAL V5.0 ST100

ABLOY EL420, EL520 Europrofile motor locks

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

QR12 (1.22 ) Diameter Optical Encoder

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

R.C.C.B. s two-pole LEXIC

Inductive sensor NI10-M18-Y1X-H1141

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

ILISC515-A Shift Interlock (Manual Lift Door) 2015 Ford Transit, 3.7L and 3.5L

AD425S Automatic door operator

Quick Connect. quick - simple - efficient.

Series 6000 Torque measured metal bellow coupling

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

THE ADVANTAGES ARE YOURS

Cross-beam scanning system to detect slim objects. 100 mm in

TS93 EMR T/PT/TDE. Surface applied door closer

Assisted lift operated 2/2-way solenoid valves Type EV250B

Narrow stile lock 1314

2M IR Mini Dome Quick Installation Guide

Total solder points: 57 Difficulty level: beginner advanced 3 TO 30VDC / 3A POWER SUPPLY K7203 ILLUSTRATED ASSEMBLY MANUAL H7203IP-1

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

MOUNTING AND OPERATING INSTRUCTIONS

HMI display Installation Guide

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

SECTION DETECTION AND ALARM

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Variety of Control Options Control is possible via wall switches, remote control systems or integration into building management systems.

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

User manual DinaSys DTC/DTS and DTC/DTZ

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Transcription:

CREATING LOCKING SOLUTIONS... DOCUMENTATION A1-SERIES 2009 / 2 WWW.BB-LOCKS.COM

TABLE OF CONTENT: Description of the product... Pagina 2 Characteristics... Pagina 2 Certificates... Pagina 3 Models without handle... Pagina 4 Models with handle... Pagina 5 Programmation... Pagina 6 Explanation of parts... Pagina 7 Installation instructions... Pagina 8 Mounting possibilities... Pagina 9 Accessories... Pagina 10-11 Notes... Pagina 12 Connection diagram A1-BASIC... Pagina 14-15 Connection diagram A1-SRC... Pagina 16 Notes... Pagina 17 Connection diagram A1-Multipoint... Pagina 18-19 Notes... Pagina 20 Technical drawings (locks)... Pagina 21-37 Technical drawings (security escutcheons)... Pagina 38-39 Technical drawings (baseplate fixation blocks)... Pagina 40 Technical drawings (surface mount brackets)... Pagina 41 Notes... Pagina 42 Prescription texts... Pagina 43-56 Contact details... Back cover Table of content w w w. b b - l o c k s. c o m 1

DESCRIPTION: Description & Characteristics The B&B Locks A1-series are high security locks of superior quality. Because of their very solid construction, these locks offer an extreme high resistance against all forms of agression and burglary attempts. The A1 locks are made to allow for a high frequency use. To ensure a fast and precise action, the hardened locking components are driven by a powerful solenoid. This solenoid was especially designed to have the best possible balance between activation and holding current. A low power consumption and very little heating are additional advantages of the new solenoid. Unlocking is done by giving an impulse with a push button, card reader, code, fingerprint or any other type of acces control. Mechanical unlocking is always possible using a key. The automatic locking mechanism guarantees that the door will be locked as soon as it closes. CHARACTERISTICS: 24V DC stabilized (+/- 5%) consumption: 2,2 A activation current (0,2sec) 130 ma holding current controlled and manageable access automatic locking when the door closes always locked with the main bolt when the door is closed (bolt is ejected 20 mm) mechanical opening with the cylinder is always possible from the inside the lock (HA, HX and HE) can always be opened mechanically using the handle or panic bar (emergency exit) integrated signalisation of the bolt position (unlocked / locked) integrated signalisation of the door position (open / closed) stainless steel locking components, cylinder block, baseplate and striker plate the locking components are mounted on the solid baseplate using M6 axes, which improves the free movement of the components and the lifespan of the lock integrated microprocessor controlled intelligence anti-saw pin in the bolt standard striker plate with casted on striker cup included adjustable striker plate with re-enforced striker cup (optional) possibility to have the PCB protected in a polyurethane casted resin (optional) door detection by 3 Hall-sensors instead of 1 (optional) tested to achieve 1.000.000 cycles tested to a frequency of 600 cycles a day resistance up to 25.000 N lateral pressure opening under considerable lateral pressure is still possible specially designed security escutcheons (SE-17, SE-22, SEH-17 and SEH-22) are available (optional) available for both 17mm and 22mm cylinders available in backsets of 25, 30 & 50mm (SA, SX & SE models) available in backsets of 35 & 60mm (HA, HX & HE models) available with 2 cylinder openings (PSX, PSE & PME models) distance from handle to cylinder is 72mm (HA, HX & HE models) tumbler available in 8 and 9 mm (complete bolt retraction at 30 tumbler rotation) - (HA, HX & HE models) 2

CE-certified: Ref. Nr. TCF-LDN 06.09.003 lock (according to standards EN 61000 & EN 55022) CERTIFICATE of COMPETENT BODY EN-certificates: in the framework of article 10.2 of the European Directive 89/336/EEC for EMC for Secure Lock-system model B&B A1 slot of Manufacturer B&B Locks s.a., Chemin de Tecnax 27, CH-1973 Nax, SWITZERLAND Certificates DIN EN 179 : 2008 (Emergency Exits) 3 7 6 0 1 4 5 2 A B The models A1 HA, HX en HE (all handle versions) in combination with the B&B security escutcheons SEH-17 en SEH-22 are certified to be used in emergency exit doors. DIN EN 1125 : 2008 (Panic Exits) The models A1 HA, HX en HE (all handle versions) in combination with push bar are certified to be used in panic exit doors. The certificates have been obtained in combination with the following hardware: - ECO EPN 900 panic bar 3 7 6 0 1 4 2 2 A B - WSS PS 99 panic bar 3 7 6 0 1 4 2 2 A B - WSS PD 79 push bar 3 7 6 0 1 4 2 2 B B DIN 18251 - part 1 All A1 models have been certified with the highest possible level (class 5) of this norm regarding the static pressure on the bolt. DIN EN 12209 : 2004 All A1 models have been certified with the highest possible level (class 7) of this norm regarding locks and escutcheons. DIN V EN V 1627 : 1999 All A1 models have been certified with the highest possible level (class 6) of this norm regarding burglary resistance. (Table C1 - protection against pushing back the bolt). w w w. b b - l o c k s. c o m 3

SANOCYL: unlocked without power - no cylinder block SANOCYL SA SX SE Models without handle SA: unlocked without power - with cylinder block (mechanical opening always possible with key) SX: locked without power - with cylinder block (mechanical opening always possible with key) SE: locked without power (only when door is closed) - with cylinder block (mechanical opening always possible with key) AVAILABLE BACKSETS : 25, 30 & 50 mm Standard Striker Plate with striker cup 3mm Adjustable Striker Plate with striker cup 6mm Standard Striker Plate is normally included. If you would like to upgrade to the Adjustable Striker Plate please add + ASP behind the order number. ORDER NR FORMAT: A 1 _..... -.. _.. 1 2 3 4 5 6 7 1) Lock model 2) Space 3) Programmation (BASIC or SRC) 4) Dash 5) Backset (25, 30 or 50) 6) Space 7) Lock type (SA, SX or SE) EXAMPLE: A1 BASIC-30 SX + ASP ATTENTION: Sanocyl is always A1 BASIC-SANOCYL

HA HX HE HA : Unlocked without power. Mechanical opening with key is always possible from both sides. Mechanical opening with the handle is always possible from the secure side. HX : Locked without power. Mechanical opening with key is always possible from both sides. Mechanical opening with the handle is always possible from the secure side. HE : Locked without power (only when the door is closed). Mechanical opening with key is always possible from both sides. Mechanical opening with the handle is always possible from the secure side. Models with handle AVAILABLE BACKSETS : 35 & 60 mm Standard Striker Plate with striker cup 3mm Adjustable Striker Plate with striker cup 6mm ORDER NR FORMAT: Standard Striker Plate is normally included. If you would like to upgrade to the Adjustable Striker Plate please add + ASP behind the order number. A 1 _..... -.... _.. 1 2 3 4 5 6 7 8 1) Lock model 2) Space 3) Programmation (BASIC or SRC) 4) Dash 5) Backset (35 or 60)) 6) Cylinder type (17 or 22) 7) Space 8) Lock type (HA, HX or HE)) EXAMPLE: A1 SRC-3517 HX w w w. b b - l o c k s. c o m 5

BASIC and SRC programmation: The A1 locks are available with 2 different types of programmation: BASIC program SRC program BASIC and SRC Programmation The SRC (serial communication) programmation was developped in order to be able to communicate more information about the lock to the consumer. The A1 lock has a 5-pole connector at the bottom of its printed circuit board. This allows for an easy connection of both power and signalisation wires (combined in the B&B A1 BASIC CABLE). In the A1-BASIC version pin 4 and 5 of this connector serve as the signalisation of the bolt and the door position respectively. These outputs are not potential free (used only to activate a relais or illuminate a LED). On page 15 you can find the instructions of how these outputs can be made potential free if so desired. Using the SRC programmation the lock gives us more information. It continuously communicates the status of the bolt and the door, but also tells us whether or not the key and the handle are being used. This information is transmitted over a data line, but needs to be translated in order for us to understand it. Therefore we use the SRC-1 interface, which translates this information into potential free outputs (see page 16 for more details). 6

SECURITY ESCUTCHEON Adding a security escutcheon offers a strong protection against agression on the cylinder. It is a solid casted piece fixed with 2 x M8 srews. The LOCKING PARTS are hardened steel casted parts (HRC45). Their construction principle is such that when pressure is applied to the bolt, these parts are locking even more. Together with the very high resistance against vandalism and lateral pressure this makes for the best solution in anti-intrusion locking systems. The locking components in the A1-lock are driven by a SOLENOID, which allows for a very fast locking or unlocking action. It also ensures the lock to go back to its starting position when there is no power; open in fail safe and locked in fail secure version. The solenoid was especially designed to have the best possible balance between activation and holding current, to have low consumption and no heating. The intelligence of the lock comes from a microprocessor on the PRINTED CIRCUIT BOARD, which is mounted in a plastic cup and on the baseplate. It is possible to protect the printed circuit board by covering it completely in a polyeurathane casted resin. This will protect the PCB against humidity etc. CYLINDER BLOCK is casted in 1 piece and offers the possibility to use b o t h 1 7 m m europrofile and 22mm swiss cylinders. Two different types of STRIKER PLATES (both with a cup protecting the ejected bolt) are available. The STANDARD version has oval holes for adjustment at the initial installation. The ADJUSTABLE version has a movable insert that allows for adjustments any time after installation (to compensate door imperfections). The STRIKER PLATES are very strong stainless steel plates of 3mm (standard) and 6mm (adjustable) thickness. The striker plates have 1 permanent magnet built in (invisible), which is detected by a Hallsensor on the PCB for door detection. Explanation of parts CONNECTION DIAGRAM w w w. b b - l o c k s. c o m 7

Please make sure the following installation requirements are met to ensure the correct functioning of your B&B A1 electro-mechanical lock : Installation instructions Use B&BA1-BASIC CABLE (2 x 1,5mm² + 3 x 0,22mm² - shielded)! Use 24V DC regulated POWER SUPPLY of minimum 2,5Aper lock! Make sure the distance between the power supply and the lock is maximum 25m! Mesure the voltage coming to the lock and make sure that this never drops below 22,8V (24V DC +/- 5%). (important especially when the solenoid is activated!) Make sure the distance between the lock and striker plate is min. 2mm and max. 6mm! Make sure the lock and striker plate are installed in a proper matter where the 2 are perfectly aligned (in closed door position they should be straight accross from eachother, both laterely and in height)! Make sure that there is no friction on the bolt when being ejected and retracted (this should be tested after installation of the rubbers on the profile)! Make sure the holes for inserting the cylinder are large enough so the cylinder can be easily installed without being forced. DO NOT FILE with the lock already installed! Filings that end up in or around the lock will be attracted when the solenoid is activated and will eventually damage the lock! Make sure the door is equiped with adequate hinges (according to door size and weight) to avoid «hanging» of the door! Make sure the door is equiped with an adequate door closer (according to door size and weight)! Please note that in order for the lock to function correctly the above mentioned specifications need to be strictly followed. B&B LOCKS S.A. can not be held accountable for on-site interventions and reparations under warranty if the installation was not done according to these specific instructions! BASEPLATE FIXATION BLOCKS SURFACE MOUNT BRACKETS A1 locks can of course also be installed in existing doors. Since it is not always easy to make very accurate adaptions to a door when you are on site, we have developed Baseplate Fixation Blocks ( BFB-1). Using these blocks the A1 lock will end up flush mounted on the profile (when profile used is 2mm). In case it is impossible to install the A1 lock in the door or the frame because of the width of the lock (30mm), a surface mount application can be considered. The Surface Mount Bracket ( SMB) consists of 4 mounting blocks and 2 stainless steel covers (1 for the lock and 1 for the striker plate), which are mounted vertically or horizontally on the secure side. 8

Sanocyl SA SX SE Sanocyl SA Mounting possibilities Sanocyl SA SX SE HA HX HE min. 2mm max. 6mm w w w. b b - l o c k s. c o m 9

Accessories B&B 24V DC STABILIZED POWER SUPPLY - PS24D52 24V Power Supply for 2 locks with back-up battery connexion CON1 = INPUT 220V/50Hz 120VA CON2 = connection to back-up batteries (3 x 12V) CON3 = Extra output 12V/DC maximum 0,2A CON4 = Output 24V/DC, 4A peak, 1A continuous (LOCK1) CON5 = Output 24V/DC, 4A peak, 1A continuous (LOCK2) All outputs have a short-circuit protection, in case of a short circuit on the 24V, LED1 will illuminate. In case of overheating because of a surcharge, LED1 will also indicate an error. A possible voltage drop (which is possible over a long line) can partially be compensated by adjusting the TRIM2 (current compensation in power supply). The principle is such that the outgoing voltage only increases when a voltage peak is needed (not continuously). B&B A1-BASIC CABLE Cable with 2 x ø1,5mm and 3 x ø0,22mm wires + shielding RED : power +24V BLUE : GND (0V) BLACK : unlucking impulse (to GND) BROWN : bolt signal YELLOW : door signal CB1 - PUSH BUTTON WITH BOLT & DOOR SIGNALIZATION The CB1 control box has the following functions: push button (1 time opening) rocker switch (continuous opening) bolt status signalization LED s door status signalization LED s REL-1 (POTENTIAL FREE CONTACTS BOLT & DOOR) Turns the bolt and door signals coming from the A1-BASIC into potential free outputs. (see page 15 for connection diagram) SRC-1 (POTENTIAL FREE CONTACTS BOLT, DOOR, KEY & HANDLE) Turns signal-a and signal-b lines coming from the A1-SRC into potential free outputs. (see page 16 for connection diagram) 10

B&B SE17 (for models SA, SX & SE) Security escutcheon for 17mm europrofile cylinder. B&B SE22 (for models SA, SX & SE) Security escutcheon for 22mm Swiss cylinder. B&B SEH17 (for models HA, HX & HE) Security escutcheon with handle for 17mm europrofile cylinder. Accessories B&B SEH22 (for models HA, HX & HE) Security escutcheon with handle for 22mm Swiss cylinder. BFB-1 (BASEPLATE FIXATION BLOCK) In order to make the installation of the A1 locks in existing doors easier. Using these blocks the A1 lock will end up flush mounted on the profile (when the profile used is 2mm). SMB (SURFACE MOUNT BRACKET) The surface mount bracket ( SMB) consists of 2 fixation blocks and 1 stainless steel cover. The installation needs to be done on the secure side of the door and can be vertical as well as horizontal. Available models: SMB-SN: for the A1 Sanocyl and the striker plate - this cover has no cylinder opening SMB-L: for the A1 with backset 30mm and 17 or 22mm cylinder, when the lock is installed to the Left of the striker plate; fixation holes are made for mounting the security escutcheons (SE-17 or SE-22). In case the security escutcheon is not used cylinder cover plates are available (CC-17 and CC-22 for 17 and 22mm cylinders respectively) SMB-R: idem, but used when the lock is installed to the Right of the striker plate SMBH-L: for the A1 with backset 35mm and 17 or 22mm cylinder, when the lock is installed to the Left of the striker plate; fixation holes are made for mounting the security escutcheons with handle (SEH-17 or SEH-22). SMBH-R: idem, but used when the lock is installed to the Right of the striker plate w w w. b b - l o c k s. c o m 11

Notes 12

CONNECTION DIAGRAMS Connection diagrams w w w. b b - l o c k s. c o m 13

1 2 1 2 3 4 5 24V POWER SUPPLY - PS24D52 A1 ELECTRO-MECHANICAL SECURITY LOCK A1 BASIC - connection POWER SUPPLY PS24D52 CON1 = power input 1&2 = 220V/50HZ 3 = EARTH CON2 = BATTERY CHARGER 3X12V 1=GND 2 = split at 2/3 = 24V (only input!) 3 = charger I out = 0.2A / U out max ~ 41,0V CON3 = EXTRA 12V POWER SUPPLY OUTPUT 1=GND 2 = 12Vdc/0.2A B&B LOCKS A1-BASIC PUSH BUTTON with DOOR and BOLT SIGNALISATION CB 1 SCHIELDING to GND CON2 +24V/DC GND CON1 +24V / red GND / blue Unlock / black BOLT SIGN / brown DOOR SIGN / yellow 1=GND 2 = +24V/DC SCHIELDING to EARTH/GND 3 = EARTH/GND CON4 = CONNECTION LOCK 1 Maximum total cable length = 25m Always connect shielding to GND or EARTH only on 1 side CON5 = CONNECTION LOCK 2 B&B LOCKS A1-BASIC A1 LOCK +24V (wire ø 1,5 mm) 0V (GND) (wire ø 1,5 mm) Openingsimpulse to GND Bolt Signalisation (Bolt out = 0V) Door Signalisation (Door closed = 0V) 14

1 2 3 4 5 1 2 3 4 5 A1 ELECTRO-MECHANICAL SECURITY LOCK FUNCTION: The bolt and door signals are transistor switches inside the lock, which are put to GND when activated (max 20mA with 24V DC). These outputs are not potential free! It is possible to activate a relais switch (which in turn makes the output potential free), or to light up a LED (when put in series with a resistance). The positive terminal (of the relais or the LED) has to be connected to the +24V DC (= pin 1) and the other side to pin 4 and/or pin 5 for bolt and door signalisation respectively. When the bolt and/or door signalisation are active they are put to GND (= pin 2) and the relais are activated or the LED s are lit. OPTION 1: make the outputs potential free +24vDC red GND blue In-UnlockCommand NO NC BOLT GALVANIC FREE COM NO NC DOOR GALVANIC FREE black OPTION 2: illuminate LED s +24vDC GND red blue COM In-UnlockCommand black 15mA R1 + RELAIS 24V/DC less than 20mA with limit diode + RELAIS 24V/DC less than 20mA with limit diode CON1 CON1 Transistor switch to GND S1 with short circuit protection. Maximum = 24V/DC Current limitation = 20mA S2 Transistor switch to GND with short circuit protection S1 Maximum = 24V/DC Current limitation = 20mA S2 BOLT out = S1 closed BOLT in = S1 open DOOR closed = S2 closed DOOR open = S2 open BOLT out = S1 closed BOLT in = S1 open DOOR closed = S2 closed DOOR open = S2 open A1 BASIC - connection BOLT SIGNALISATION LED1 1K5 DOOR SIGNALISATION 15mA R2 1K5 LED2 Connect 1 relais to the +24V and the bolt signal. When the bolt is out, the transistor switch in the lock closes, which will activate the relais (so the NO of the relais will be closed and the NC of the relais will be open). The following values can be measured with an Ω- meter: between C and NO: infinity when open, 0Ω when closed between C and NC: infinity when open, 0Ω when closed Connect 1 relais to the +24V and the door signal. When the door is closed, the transistor switch in the lock closes, which will activate the relais (so the NO of the relais will be closed and the NC of the relais will be open). The following values can be measured with an Ω- meter: between C and NO: infinity when open, 0Ω when closed between C and NC: infinity when open, 0Ω when closed REL1: In order to make it easy for the installer and the end-user to use the A1 locks to their full potential, we are offering the REL-1. This is a small printed circuit board, which can easily be connected to the lock in case the bolt and door signals are needed potential free. COM/1 - BOLT SIGNAL NC/1 - BOLT UNLOCKED NO/1 - BOLT LOCKED COM/2 - DOOR SIGNAL NC/2 - DOOR OPEN NO/2 - DOOR CLOSED DOOR SIGNAL BOLT SIGNAL +24V/DC POTENTIAL FREE OUTPUTS A1 LOCK w w w. b b - l o c k s. c o m 15

L N PE 1 2 3 4 5 6 7 8 9 10 11 230 V ~ 50Hz 0,7 A EXTERNAL FUSE 250 V/ 2A T PS 24 D52 CE 3x12V/4-6Ah BACK-UP BATTERY POWER 12V= 0,2 A SPARE OUTPUT BACK-UP BATTERY OVERLOAD ALARM LED3 LED2 LED4 24V= 1 2 3 4 5 6 7 8 9 10 11 12 LED1 24V= LOCK1 LOCK2 CAUTION : to prevent electric shock do not remove cover when 230V input is switched on. For cable length adjustment, see note inside A1 ELECTRO-MECHANICAL SECURITY LOCK A1 SRC - connection +24V (wire ø 1,5 mm) 0V (GND) (wire ø 1,5 mm) Openingsimpulse to GND Signal 1 INTERNE LED POWER BACK-UP BATTERY OVERLOAD ALARM PS 24 D52 24 V DC POWER SUPPLY sense technology INTERNAL FUSE 250 V / 2A T BACK-UP BATTERY SPARE OUTPUT LOCK 1 3x12V/4-6Ah 24V 36V 24V 36V 12V= 0,2A SHIELDING SCHIELDING LOCK 2 SCHIELDING www.bb-locks.com 230 V~ 50 Hz 0,7 A 24V= 24V= SHIELDING CON1 CON1 = power input 3 2 1 L N PE CON2 3 2 1 1 2 3 4 5 2 1 6 7 8 CON4 3 2 1 9 1011 CON5 3 2 1 Signal 2 24V POWER SUPPLY WITH BACK-UP BATTERY CONNEXION 1&2 = 220V/50HZ 3 = EARTH CON2 = BATTERY CHARGER 3X12V 1 = GND 2 = split at 2/3 = 24V (only input!) CON3 3 = charger I out = 0.2A / U out max ~ 41,0V CON3 = EXTRA 12V POWER OUTPUT GND +12V/DC / 0,2A GND +24V/DC EARTH/GND CON4 = CONNECTION LOCK 1 CON5 = CONNECTION LOCK 2 SCHIELDING to EARTH/GND OPENING IMPULS B&B LOCKS A1-BASIC B&B LOCKS A1-BASIC 1 2 3 4 5 A1 LOCK 24V DC +/-5% 2.5A UNLOCK SIGNAL-A SIGNAL-B Maxmium total cable length = 25m Cable = B&B A1-BASIC CABLE (2x1,5 = 3x0,22 ) CON1 A1 multi signal SRC-1 SERIAL DECODER ON DINRAIL +24V/DC GND IMPULSE 1 GND +24V/DC GND IMPULSE 1 SIGNAL/A SIGNAL/B NC4 NO4 COM4 NC3 NO3 COM3 NC2 NO2 COM2 NC1 NO1 COM1 13 14 15 16 17 18 19 20 21 22 23 24 www.bb-locks.com POTENTIAL FREE OUTPUTS HANDLE USED HANDLE NOT IN USE HANDLE SIGNAL KEY ACTIVATED KEY NOT IN USE KEY SIGNAL DOOR OPEN DOOR CLOSED DOOR SIGNAL BOLT RETRACTED BOLT EJECTED BOLT SIGNAL POWER SUPPLY PS24D52 SRC-1 16

Notes w w w. b b - l o c k s. c o m 17

1 2 3 4 5 6 7 8 9 10 11 12 A1 ELECTRO-MECHANICAL SECURITY LOCK ATTENTION!!! There is 1 main lock (when a lock with handle is installed this is always the main lock), which is programmed with the multi-signal program (SRC - serial communication). The additional locks are programmed with the BASIC program. A1 MULTIPOINT - connection 2x1,5mm² POWER SUPPLY CABLE B&B A1 BASIC CABLE (2x1,5mm² + 3x0,22mm²) the different locks are connected in parrellel (both the power supply and the opening impulses) all connected locks will unlock simultaneously (both in case of an electrical impulse from the access control and in case of opening of the main lock by key or handle) in case 1 bolt can be vandalised the other bolts will remain locked the potential free outputs give all the information about the main lock (position of the door, position of the bolt, key being used, handle being used) the PS24D52 is strong enough to supply 2 doors with 3 locks each simultaniously the total length of cable from the power supply to the locks can be 25m max NC NC NC NC ADDITIONAL LOCK - with BASIC program MAIN LOCK - with SRC program ADDITIONAL LOCK - with BASIC program CONNECTION TO POWER SUPPLY PS 24 D52 OPENING IMPULSE CONNECTION TO THE LOCKS CON1 SRC-2 SERIAL DECODER ON DINRAIL +24V/DC GND IMPULSE 1 GND +24V/DC GND IMPULSE 1 SIGNAL/A SIGNAL/B NC4 NO4 COM4 NC3 NO3 COM3 NC2 NO2 COM2 NC1 NO1 COM1 13 14 15 16 17 18 19 20 21 22 23 24 POTENTIAL FREE OUTPUTS HANDLE USED HANDLE NOT IN USE HANDLE SIGNAL KEY ACTIVATED KEY NOT IN USE KEY SIGNAL DOOR OPEN DOOR CLOSED DOOR SIGNAL BOLT RETRACTED BOLT EJECTED BOLT SIGNAL 18

SRC-2 ON 1 2 ON 1 2 The normal function of this multi-point locking solution is that each opening impulse (whether given by access control, key or handle) will simultaneously open all locks. This is the case when you put both switch 1 (=key) and switch 2 (=handle) in the ON position. If so desired it is possible to deactivate the transfer of the opening impulse (from key and/or handle). The main lock will still open but the additional locks will remain in the locked position so the door can not be opened. The opening impuls given by access control will always open all locks simultaneously. Both switches in the ON position: opening impulse given by access control is transferred and all locks open simultaneously opening impulse given by the key is transferred and all locks open simultaneously opening impulse given by the handle is transferred and all locks open simultaneously Switch 1 = ON, switch 2 = OFF: opening impulse given by access control is transferred and all locks open simultaneously opening impulse given by the key is transferred and all locks open simultaneously opening impulse given by the handle is not transferred and only the main lock opens A1 MULTIPOINT - connection ON 1 2 Switch 1 = OFF, switch 2 = ON: opening impulse given by access control is transferred and all locks open simultaneously opening impulse given by the key is not transferred and only the main lock opens opening impulse given by the handle is transferred and all locks open simultaneously ON 1 2 Switch 1 = OFF, switch 2 = OFF: opening impulse given by access control is transferred and all locks open simultaniously opening impulse given by the key is not transferred and only the main lock opens opening impulse given by the handle is not transferred and only the main lock opens w w w. b b - l o c k s. c o m 19

Notes 20

TECHNICAL DRAWINGS Technical drawings w w w. b b - l o c k s. c o m 21

A1 SANOCYL 22

A1 SANOCYL + ASP w w w. b b - l o c k s. c o m 23

A1 25 24

A1 25 + ASP w w w. b b - l o c k s. c o m 25

A1 30 26

A1 30 + ASP w w w. b b - l o c k s. c o m 27

A1 50 28

A1 50 + ASP w w w. b b - l o c k s. c o m 29

A1 3517 30

A1 3517 + ASP w w w. b b - l o c k s. c o m 31

A1 6017 32

A1 6017 + ASP w w w. b b - l o c k s. c o m 33

A1 3522 34

A1 3522 + ASP w w w. b b - l o c k s. c o m 35

A1 6022 36

A1 6022 + ASP w w w. b b - l o c k s. c o m 37

SE-17 SECURITY ESCUTCHEONS WITHOUT HANDLE SE-17 and SE-22 SE-22 38

SEH-17 SEH-22 SECURITY ESCUTCHEONS WITH HANDLE SEH-17 and SEH-22 w w w. b b - l o c k s. c o m 39

BFB - baseplate fixation blocks 40

SMB-L SMB-R SMB-SN SMBH-L SMBH-R CC-17 CC-22 SMB - surface mount brackets w w w. b b - l o c k s. c o m 41

Notes 42

PRESCRIPTION TEXTS Prescription texts w w w. b b - l o c k s. c o m 43

High-quality electro-mechanical security lock, model 'A1-SANOCYL', working according the fail safe principle (=unlocked without current). Locking by solenoid; unlocking by spring force when no current is supplied. Due to its solid construction (massive casted base plate and casehardened locking components), the characteristics of a security lock are combined with those of an anti-panic lock. Prescription Text : B&B A1 Basic SANOCYL - Fail Safe Lock witout cylinder (½) OPERATION: After the door has been closed, the lock will detect the striker plate using a hall sensor on the PCB. Then the bolt is thrown out by a single acting electro-magnet and immediately blocked by means of a deadlock. The lock will now switch from activation to holding current. In order to unlock, a connection must be made, by means of a switch, between terminal clamp 2 and 3. The current to the solenoid is then interrupted by the internal printed circuit board, forcing the bolt to retract by means of springs. The bolt will remain retracted until the door closes and the sriker plate has been detected (when no permanent contact is made between the 2 terminal clamps mentioned before). MATERIALS: Base plate : stainless steel AISI 304 (investment casting) 10mm thick Bolt and locking mechanism : case hardened (45 RC) chromium-nickel steel (investment casting) Housing, cover plates and striker plate : stainless steel AISI 304 (partly laser cut, partly investment casting) FEATURES: electro-mechanical security lock working with 24 V and low consumption (using a custom made solenoid for fast action and low heating): o 2,2 A activation current (moment of locking) o 130 ma holding current (permanent locking) controlled and manageable access unlucking by impuls unlocked without power automatic locking when the door closes always locked with the main bolt when the door is closed (bolt is ejected 20 mm) integrated signalisation of the bolt position (unlocked/locked) and the door position (open/closed) which can signal the status of the lock at a remote control room stainless steel locking components, baseplate and striker plate the locking components are mounted on the solid, 10mm thick, baseplate using M6 axes, which improves the free movement of the components and the lifespan of the lock integrated microprocessor controlled intelligence symmetrical bolt with anti-saw pin, for both bumper doors and revolving (180 ) doors. standaard striker plate (3mm) with casted on striker cup included adjustable striker plate (6mm) with re-enforced striker cup (optional) 44

possibility to have the PCB protected in a polyurethane casted resin (optional) doordetection by 3 Hall-sensors instead of 1 (optional) tested to achieve 1.000.000 cycles tested to a frequency of 600 cycles a day resistance up to 25.000 N lateral pressure opening under lateral pressure still possible up to 500 N (depending on installation) restart : the lock will re-do 3 attempts to close after the first attempt when not properly locked power supply PS24D52 : 24V = direct current +/- 5%. Warranty of lock invalid if this power supply is not used! connection via removable plugs with screw clamps (wire section 1,5 mm²) B&B Locks Cable (2 x 1,5 mm² + 3 x 0,22mm²) Warranty of lock invalid if this cable is not used! APPLICATIONS: Merchandise interlocking units; entrance and communicating doors in public buildings, hotels, airports, shopping centers, parliament buildings, hospitals etc. Possibility to mount them horizontally above the door. INSTALLATION: Installation instructions and connection diagram : see documentation. When installing the lock, make sure there is a proper and spotless recess. Furthermore, make sure the clearance between the cover plate of the lock and the striker plate is at least 2mm and maximum 6mm. In case of a revolving (180 ) door, it must perfectly stop in the 0-position; a door which is not in the exact position cannot be locked. A proper floor spring with adjustable stop and 0-position is a good solution. With these doors it is advisable to provide more lateral clearance. It also goes without saying that both door and doorframe must be sufficiently rigid and that the lock must be firmly installed for correct operation. Prescription Text : B&B A1 Basic SANOCYL - Fail Safe Lock witout cylinder (2/2) OPTIONS: Solid striker plate (6mm thick) with adjustable striker cup (a movable insert that allows adjustments : 2mm to the left and 2mm to the right). PCB protected in polyurethane casted resin against humidity, etc. & door detection by 3 Hall-sensors instead of 1 Hall-sensor. BFB-1: Baseplate fixation blocks SMB: Surface mount bracket REL-1: Printed circuit board to transform the bolt and door signals coming from the A1- BASIC lock into potential free outputs. w w w. b b - l o c k s. c o m 45

High-quality electro-mechanical security lock, model 'A1-SA', working according the fail safe principle (=unlocked without current). Locking by solenoid; unlocking by spring force or by using a cylinder. Due to its solid construction (massive casted base plate and case-hardened locking components), the characteristics of a security lock are combined with those of an anti-panic lock. Prescription text : B&B A1 Basic SA - Fail safe lock with cylinder block, without handle (½) OPERATION: After the door has been closed, the lock will detect the striker plate using a hall sensor on the PCB. Then the bolt is thrown out by a single acting electro-magnet and immediately blocked by means of a deadlock. The lock will now switch from activation to holding current. In order to unlock, a connection must be made, by means of a switch, between terminal clamp 2 and 3. The current to the solenoid is then interrupted by the internal printed circuit board, forcing the bolt to retract by means of springs. Using a cylinder, the lock can also be unlocked mechanically, in which case the current supply to the solenoid is also interrupted (using a microswitch on the slider). After the door has been opened, the key must be turned back and removed from the cylinder. The bolt will remain retracted until the door closes and the sriker plate has been detected (when no permanent contact is made between the 2 terminal clamps mentioned before). MATERIALS: Base plate : stainless steel AISI 304 (investment casting) 10mm thick Bolt and locking mechanism : case hardened (45 RC) chromium-nickel steel (investment casting) Cylinder block : stainless steel AISI 304 (investment casting) solid block Housing, cover plates and striker plate : stainless steel AISI 304 (partly laser cut, partly investment casting) FEATURES: electro-mechanical security lock working with 24 V and low consumption (using a custom made solenoid for fast action and low heating): o 2,2 A activation current (moment of locking) o 130 ma holding current (permanent locking) controlled and manageable access unlucking by impuls unlocked without power automatic locking when the door closes always locked with the main bolt when the door is closed (bolt is ejected 20 mm) mechanical opening with the cylinder is always possible integrated signalisation of the bolt position (unlocked/locked) and the door position (open/closed) which can signal the status of the lock at a remote control room stainless steel locking components, cylinder block, baseplate and striker plate the locking components are mounted on the solid, 10mm thick, baseplate using M6 axes, which improves the free movement of the components and the lifespan of the lock integrated microprocessor controlled intelligence symmetrical bolt with anti-saw pin, for both bumper doors and revolving (180 ) doors. standaard striker plate (3mm) with casted on striker cup included adjustable striker plate (6mm) with re-enforced striker cup (optional) 46

possibility to have the PCB protected in a polyurethane casted resin (optional) doordetection by 3 Hall-sensors instead of 1 (optional) tested to achieve 1.000.000 cycles tested to a frequency of 600 cycles a day resistance up to 25.000 N lateral pressure opening under lateral pressure still possible up to 500 N (depending on installation) specially designed security escutcheon (SE-17 of SE-22) both 17mm and 22mm cylinders can be used available in backsets of 25mm, 30mm and 50 mm restart : the lock will re-do 3 attempts to close after the first attempt when not properly locked power supply PS24D52 : 24V = direct current +/- 5%. Warranty of lock invalid if this power supply is not used! connection via removable plugs with screw clamps (wire section 1,5 mm²) B&B Locks Cable (2 x 1,5 mm² + 3 x 0,22mm²) Warranty of lock invalid if this cable is not used! APPLICATIONS: Escape doors, entrance doors and communicating doors in public buildings, hotels, airports, shopping centers, parliament buildings, hospitals etc. INSTALLATION: Installation instructions and connection diagram : see documentation. When installing the lock, make sure there is a proper and spotless recess. The cylinder recess must allow easy installation of the cylinder even after the lock has been mounted. This way, there will be no tension on the base plate when the cylinder is tightened. Furthermore, make sure the clearance between the cover plate of the lock and the striker plate is at least 2mm and maximum 6mm. In case of a revolving (180 ) door, it must perfectly stop in the 0-position; a door which is not in the exact position cannot be locked. A proper floor spring with adjustable stop and 0-position is a good solution. With these doors it is advisable to provide more lateral clearance. It also goes without saying that both door and doorframe must be sufficiently rigid and that the lock must be firmly installed for correct operation. OPTIONS: Solid striker plate (6mm thick) with adjustable striker cup (a movable insert that allows adjustments : 2mm to the left and 2mm to the right). PCB protected in polyurethane casted resin against humidity, etc. & door detection by 3 Hall-sensors instead of 1 Hall-sensor. Security escutcheon SE-17 or SE-22 (solid casted piece) fixed with 2 x M8 screws, offers a strong protection against aggression on the cylinder and gives an extra anchoring for the lock. BFB-1: Baseplate fixation blocks SMB: Surface mount bracket REL-1: Printed circuit board to transform the bolt and door signals coming from the A1- BASIC lock into potential free outputs. SRC-1: Din rail box, which translates the information coming from the A1-SRC lock and turns them into potential free outputs (position of the bolt and the door, use of the key and the handle). Prescription text : B&B A1 Basic SA - Fail safe lock with cylinder block, without handle (2/2) w w w. b b - l o c k s. c o m 47

High-quality electro-mechanical security lock, model 'A1-SX', working according the fail secure principle (=locked without current). Unlocking by giving an electrical impulse that activates a solenoid or mechanically by using a key. Locking by spring force when no power is supplied. Due to its solid construction (massive casted base plate and case-hardened locking components) and to the fact the lock is permanently secured when the bolt is thrown out, the lock offers high resistance against all kinds of burglar attempts. Prescription text : B&B A1 Basic SX - Fail secure lock with cylinder block, without handle (½) OPERATION: After the door has been closed, the lock will detect the striker plate using a hall sensor on the PCB. Then the bolt is thrown out by spring force and immediately blocked by means of a deadlock. In order to unlock the door, 2 terminal clamps (n 2 and 3) must be connected by means of a switch, following which an electronic control print will activate the solenoid, which pulls in the bolt. The lock will now switch from activation to holding current. Using a profile cylinder, the lock can also be released mechanically following which the solenoid is also activated. After the door has been opened, the key must be turned back and removed from the cylinder. The lock will remain electronically unlocked until the door again closes (when there is no permanent contact between the 2 terminal clamps mentioned before). When the door does not open after the unlocking impulse has been given the lock will relock automatically after 5 seconds. MATERIALS: Base plate : stainless steel AISI 304 (investment casting) 10mm thick Bolt and locking mechanism : case hardened (45 RC) chromium-nickel steel (investment casting) Cylinder block : stainless steel AISI 304 (investment casting) solid block Housing, cover plates and striker plate : stainless steel AISI 304 (partly laser cut, partly investment casting) FEATURES: electro-mechanical security lock working with 24 V and low consumption (using a custom made solenoid for fast action and low heating): o 2,2 A activation current (moment of unlocking) o 130 ma holding current (permanent unlocking) controlled and manageable access unlucking by impuls locked without power automatic locking when the door closes always locked with the main bolt when the door is closed (bolt is ejected 20 mm) mechanical opening with the cylinder is always possible integrated signalisation of the bolt position (unlocked/locked) and the door position (open/closed) which can signal the status of the lock at a remote control room stainless steel locking components, cylinder block, baseplate and striker plate the locking components are mounted on the solid, 10mm thick, baseplate using M6 axes, which improves the free movement of the components and the lifespan of the lock integrated microprocessor controlled intelligence symmetrical bolt with anti-saw pin, for both bumper doors and revolving (180 ) doors. standaard striker (3mm) plate with casted on striker cup included adjustable striker plate (6mm) with re-enforced striker cup (optional) 48

possibility to have the PCB protected in a polyurethane casted resin (optional) doordetection by 3 Hall-sensors instead of 1 (optional) tested to achieve 1.000.000 cycles tested to a frequency of 600 cycles a day resistance up to 25.000 N lateral pressure opening under lateral pressure still possible up to 500 N (depending on installation) specially designed security escutcheon (SE-17 of SE-22) both 17mm and 22mm cylinders can be used available in backsets of 25mm, 30mm and 50 mm restart : the lock will re-do 3 attempts to close after the first attempt when not properly locked power supply PS24D52 : 24V = direct current +/- 5%. Warranty of lock invalid if this power supply is not used! connection via removable plugs with screw clamps (wire section 1,5 mm²) B&B Locks Cable (2 x 1,5 mm² + 3 x 0,22mm²) Warranty of lock invalid if this cable is not used! APPLICATIONS: Doors that require permanent locking : banks, prisons, post offices, jewelry shops, computer departments, laboratories, exchange offices, etc. INSTALLATION: Installation instructions and connection diagram : see documentation. When installing the lock, make sure there is a proper and spotless recess. The cylinder recess must allow easy installation of the cylinder even after the lock has been mounted. This way, there will be no tension on the base plate when the cylinder is tightened. Furthermore, make sure the clearance between the cover plate of the lock and the striker plate is at least 2mm and maximum 6mm. In case of a revolving (180 ) door, it must perfectly stop in the 0-position; a door which is not in the exact position cannot be locked. A proper floor spring with adjustable stop and 0-position is a good solution. With these doors it is advisable to provide more lateral clearance. It also goes without saying that both door and doorframe must be sufficiently rigid and that the lock must be firmly installed for correct operation. OPTIONS: Solid striker plate (6mm thick) with adjustable striker cup (a movable insert that allows adjustments : 2mm to the left and 2mm to the right). PCB protected in polyurethane casted resin against humidity, etc. & door detection by 3 Hall-sensors instead of 1 Hall-sensor. Security escutcheon SE-17 or SE-22 (solid casted piece) fixed with 2 x M8 screws, offers a strong protection against aggression on the cylinder and gives an extra anchoring for the lock. BFB-1: Baseplate fixation blocks SMB: Surface mount bracket REL-1: Printed circuit board to transform the bolt and door signals coming from the A1- BASIC lock into potential free outputs. SRC-1: Din rail box, which translates the information coming from the A1-SRC lock and turns them into potential free outputs (position of the bolt and the door, use of the key and the handle). Prescription text : B&B A1 Basic SX - Fail secure lock with cylinder block, without handle (2/2) w w w. b b - l o c k s. c o m 49

High-quality electro-mechanical security lock, model 'A1-SE', working according the fail secure principle (=locked without current). Unlocking by giving an electrical impulse that activates a solenoid or mechanically by using a key. Locking by spring force when no power is supplied and the deadlocking bolt is pushed in (door closed). Due to its solid construction (massive casted base plate and case-hardened locking components) and to the fact the lock is permanently secured when the bolt is thrown out, the lock offers high resistance against all kinds of burglar attempts. Prescription text : B&B A1 Basic SE - Fail secure lock with cylinder block, without handle - with small deadlocking bolt (½) OPERATION: After the door has been closed, the lock will detect the striker plate using a hall sensor on the PCB. Then the bolt is thrown out by spring force (only when deadlocking bolt is pushed in) and immediately blocked by means of a deadlock. In order to unlock the door, 2 terminal clamps (n 2 and 3) must be connected by means of a switch, following which an electronic control print will activate the solenoid, which pulls in the bolt. The lock will now switch from activation to holding current. Using a profile cylinder, the lock can also be unlocked mechanically following which the solenoid is also activated. After the door has been opened, the key must be turned back and removed from the cylinder. The lock will remain unlocked electronically and mechanically until the door again closes and the striker plate is detected (when there is no permanent contact between the 2 terminal clamps mentioned before). When the door does not open after the unlocking impulse has been given the lock will relock automatically after 5 seconds. In case of a power failure when the door is open, the bolt will remain retracted mechanically (because of the small deadlocking bolt). When the door is then closed the bolt will be thrown out (using spring force) as soon as the deadlocking bolt is pushed in. The SE model can therefore be used totally mechanically without losing any of its user-friendly characteristics! MATERIALS: Base plate : stainless steel AISI 304 (investment casting) 10mm thick Bolt and locking mechanism : case hardened (45 RC) chromium-nickel steel (investment casting) Cylinder block : stainless steel AISI 304 (investment casting) solid block Housing, cover plates and striker plate : stainless steel AISI 304 (partly laser cut, partly investment casting) FEATURES: electro-mechanical security lock working with 24 V and low consumption (using a custom made solenoid for fast action and low heating): o 2,2 A activation current (moment of unlocking) o 130 ma holding current (permanent unlocking) controlled and manageable access unlucking by impuls locked without power (bolt only thrown out when door is closed!) automatic locking when the door closes always locked with the main bolt when the door is closed (bolt is ejected 20 mm) mechanical opening with the cylinder is always possible integrated signalisation of the bolt position (unlocked/locked) and the door position (open/closed), which can signal the status of the lock at a remote control room stainless steel locking components, cylinder block, baseplate and striker plate the locking components are mounted on the solid, 10mm thick, baseplate using M6 axes, which improves the free movement of the components and the lifespan of the lock 50

integrated microprocessor controlled intelligence symmetrical bolt with anti-saw pin, for both bumper doors and revolving (180 ) doors. standaard striker (3mm) plate with casted on striker cup included adjustable striker plate (6mm) with re-enforced striker cup (optional) possibility to have the PCB protected in a polyurethane casted resin (optional) doordetection by 3 Hall-sensors instead of 1 (optional) tested to achieve 1.000.000 cycles tested to a frequency of 600 cycles a day resistance up to 25.000 N lateral pressure opening under lateral pressure still possible up to 500 N (depending on installation) specially designed security escutcheon (SE-17 of SE-22) both 17mm and 22mm cylinders can be used available in backsets of 25mm, 30mm and 50 mm restart : the lock will re-do 3 attempts to close after the first attempt when not properly locked power supply PS24D52 : 24V = direct current +/- 5%. Warranty of lock invalid if this power supply is not used! connection via removable plugs with screw clamps (wire section 1,5 mm²) B&B Locks Cable (2 x 1,5 mm² + 3 x 0,22mm²) Warranty of lock invalid if this cable is not used! APPLICATIONS: Doors that require permanent locking : banks, prisons, post offices, jewelry shops, computer departments, laboratories, exchange offices, etc. INSTALLATION: Installation instructions and connection diagram : see documentation. When installing the lock, make sure there is a proper and spotless recess. The cylinder recess must allow easy installation of the cylinder even after the lock has been mounted. This way, there will be no tension on the base plate when the cylinder is tightened. Furthermore, make sure the clearance between the cover plate of the lock and the striker plate is at least 2mm and maximum 6mm. In case of a revolving (180 ) door, it must perfectly stop in the 0-position; a door which is not in the exact position cannot be locked. A proper floor spring with adjustable stop and 0-position is a good solution. With these doors it is advisable to provide more lateral clearance. It also goes without saying that both door and doorframe must be sufficiently rigid and that the lock must be firmly installed for correct operation. Prescription text : B&B A1 Basic SE - Fail secure lock with cylinder block, without handle - with small deadlocking bolt (2/2) OPTIONS: Solid striker plate (6mm thick) with adjustable striker cup (a movable insert that allows adjustments : 2mm to the left and 2mm to the right). PCB protected in polyurethane casted resin against humidity, etc. & door detection by 3 Hallsensors instead of 1 Hall-sensor. Security escutcheon SE-17 or SE-22 (solid casted piece) fixed with 2 x M8 screws, offers a strong protection against aggression on the cylinder and gives an extra anchoring for the lock. BFB-1: Baseplate fixation blocks SMB: Surface mount bracket REL-1: Printed circuit board to transform the bolt and door signals coming from the A1-BASIC lock into potential free outputs. SRC-1: Din rail box, which translates the information coming from the A1-SRC lock and turns them into potential free outputs (position of the bolt and the door, use of the key and the handle). w w w. b b - l o c k s. c o m 51

High-quality electro-mechanical security lock, model 'A1-HX', working according the fail secure principle (=locked without current). Unlocking by giving an electrical impulse that activates a solenoid or mechanically by using a key. From the secure side this lock can also be unlocked mechanically using the handle (or push bar). Therefore one can always leave the building according to EN179 or EN1125. Locking by spring force when no power is supplied. Due to its solid construction (massive casted base plate and case-hardened locking components) and to the fact the lock is permanently secured when the bolt is thrown out, the lock offers high resistance against all kinds of burglar attempts. Prescription text : B&B A1 Basic HX - Fail secure lock with cylinder block and handle (½) OPERATION: After the door has been closed, the lock will detect the striker plate using a hall sensor on the PCB. Then the bolt is thrown out by spring force and immediately blocked by means of a deadlock. In order to unlock the door, 2 terminal clamps (n 2 and 3) must be connected by means of a switch, following which an electronic control print will activate the solenoid, which pulls in the bolt. The lock will now switch from activation to holding current. Using a cylinder (from either side), handle or push bar (from the secure side) the lock can also be released mechanically after which the solenoid is also activated. After the door has been opened, the key must be turned back and removed from the cylinder. The lock will remain electronically unlocked until the door again closes (when there is no permanent contact between the 2 terminal clamps mentioned before). When the door does not open after the unlocking impulse has been given the lock will relock automatically after 5 seconds. MATERIALS: Base plate : stainless steel AISI 304 (investment casting) 10mm thick Bolt and locking mechanism : case hardened (45 RC) chromium-nickel steel (investment casting) Cylinder block : stainless steel AISI 304 (investment casting) solid block Housing, cover plates and striker plate : stainless steel AISI 304 (partly laser cut, partly investment casting) FEATURES: electro-mechanical security lock working with 24 V and low consumption (using a custom made solenoid for fast action and low heating): o 2,2 A activation current (moment of unlocking) o 130 ma holding current (permanent unlocking) controlled and manageable access unlucking by impuls locked without power automatic locking when the door closes always locked with the main bolt when the door is closed (bolt is ejected 20 mm) mechanical opening with the cylinder is always possible from either side of the door mechanical opening with the handle or push bar is always possible from the secure side integrated signalisation of the bolt position (unlocked/locked) and the door position (open/closed) which can signal the status of the lock at a remote control room stainless steel locking components, cylinder block, baseplate and striker plate the locking components are mounted on the solid, 10mm thick, baseplate using M6 axes, which improves the free movement of the components and the lifespan of the lock integrated microprocessor controlled intelligence symmetrical bolt with anti-saw pin, for both bumper doors and revolving (180 ) doors. standaard striker (3mm) plate with casted on striker cup included adjustable striker plate (6mm) with re-enforced striker cup (optional) 52

possibility to have the PCB protected in a polyurethane casted resin (optional) doordetection by 3 Hall-sensors instead of 1 (optional) tested to achieve 1.000.000 cycles tested to a frequency of 600 cycles a day resistance up to 25.000 N lateral pressure opening under lateral pressure still possible up to 500 N (depending on installation) specially designed security escutcheon with handle (SEH-17 of SEH-22) available for both 17mm and 22mm cylinders available in backsets of 35mm and 60 mm restart : the lock will re-do 3 attempts to close after the first attempt when not properly locked power supply PS24D52 : 24V = direct current +/- 5%. Warranty of lock invalid if this power supply is not used! connection via removable plugs with screw clamps (wire section 1,5 mm²) B&B Locks Cable (2 x 1,5 mm² + 3 x 0,22mm²) Warranty of lock invalid if this cable is not used! APPLICATIONS: Doors that require permanent locking : banks, prisons, post offices, jewelry shops, computer departments, laboratories, exchange offices, etc., but where a mechanical exit using a handle or panic bar should always be possible. INSTALLATION: Installation instructions and connection diagram : see documentation. When installing the lock, make sure there is a proper and spotless recess. The cylinder recess must allow easy installation of the cylinder even after the lock has been mounted. This way, there will be no tension on the base plate when the cylinder is tightened. Furthermore, make sure the clearance between the cover plate of the lock and the striker plate is at least 2mm and maximum 6mm. In case of a revolving (180 ) door, it must perfectly stop in the 0-position; a door which is not in the exact position cannot be locked. A proper floor spring with adjustable stop and 0-position is a good solution. With these doors it is advisable to provide more lateral clearance. It also goes without saying that both door and doorframe must be sufficiently rigid and that the lock must be firmly installed for correct operation. OPTIONS: Solid striker plate (6mm thick) with adjustable striker cup (a movable insert that allows adjustments : 2mm to the left and 2mm to the right). PCB protected in polyurethane casted resin against humidity, etc. & door detection by 3 Hallsensors instead of 1 Hall-sensor. Security escutcheon with handle SEH-17 or SEH-22 (solid casted piece) fixed with 2 x M8 screws, offers a strong protection against aggression on the cylinder and gives an extra anchoring for the lock. BFB-1: Baseplate fixation blocks SMB: Surface mount bracket REL-1: Printed circuit board to transform the bolt and door signals coming from the A1-BASIC lock into potential free outputs. SRC-1: Din rail box, which translates the information coming from the A1-SRC lock and turns them into potential free outputs (position of the bolt and the door, use of the key and the handle). Prescription text : B&B A1 Basic HX - Fail secure lock with cylinder block and handle (2/2) w w w. b b - l o c k s. c o m 53

Prescription text : B&B A1 Basic HE - Fail secure lock with cylinder block and handle - with small deadlocking bolt (1/3) High-quality electro-mechanical security lock, model 'A1-HE', working according the fail secure principle (=locked without current). Unlocking by giving an electrical impulse that activates a solenoid or mechanically by using a key. From the secure side this lock can also be unlocked mechanically using the handle (or push bar). Therefore one can always leave the building according to EN179 or EN1125. Locking by spring force when no power is supplied and the deadlocking bolt is pushed in (door closed). Due to its solid construction (massive casted base plate and case-hardened locking components) and to the fact the lock is permanently secured when the bolt is thrown out, the lock offers high resistance against all kinds of burglar attempts. OPERATION: After the door has been closed, the lock will detect the striker plate using a hall sensor on the PCB. Then the bolt is thrown out by spring force (only when deadlocking bolt is pushed in) and immediately blocked by means of a deadlock. In order to unlock the door, 2 terminal clamps (n 2 and 3) must be connected by means of a switch, following which an electronic control print will activate the solenoid, which pulls in the bolt. The lock will now switch from activation to holding current. Using a cylinder (from either side), handle or push bar (from the secure side) the lock can also be released mechanically after which the solenoid is also activated. After the door has been opened, the key must be turned back and removed from the cylinder. The lock will remain electronically unlocked until the door again closes (when there is no permanent contact between the 2 terminal clamps mentioned before). When the door does not open after the unlocking impulse has been given the lock will relock automatically after 5 seconds. In case of a power failure when the door is open, the bolt will remain retracted mechanically (because of the small deadlocking bolt). When the door is then closed the bolt will be thrown out (using spring force) as soon as the deadlocking bolt is pushed in. The HE model can therefore be used totally mechanically without losing any of its user-friendly characteristics! MATERIALS: Base plate : stainless steel AISI 304 (investment casting) 10mm thick Bolt and locking mechanism : case hardened (45 RC) chromium-nickel steel (investment casting) Cylinder block : stainless steel AISI 304 (investment casting) solid block Housing, cover plates and striker plate : stainless steel AISI 304 (partly laser cut, partly investment casting) 54

FEATURES: electro-mechanical security lock working with 24 V and low consumption (using a custom made solenoid for fast action and low heating): o 2,2 A activation current (moment of unlocking) o 130 ma holding current (permanent unlocking) controlled and manageable access unlucking by impuls locked without power automatic locking when the door closes always locked with the main bolt when the door is closed (bolt is ejected 20 mm) mechanical opening with the cylinder is always possible from either side of the door mechanical opening with the handle or push bar is always possible from the secure side integrated signalisation of the bolt position (unlocked/locked) and the door position (open/closed) which can signal the status of the lock at a remote control room stainless steel locking components, cylinder block, baseplate and striker plate the locking components are mounted on the solid, 10mm thick, baseplate using M6 axes, which improves the free movement of the components and the lifespan of the lock integrated microprocessor controlled intelligence symmetrical bolt with anti-saw pin, for both bumper doors and revolving (180 ) doors. standaard striker (3mm) plate with casted on striker cup included adjustable striker plate (6mm) with re-enforced striker cup (optional) possibility to have the PCB protected in a polyurethane casted resin (optional) doordetection by 3 Hall-sensors instead of 1 (optional) tested to achieve 1.000.000 cycles tested to a frequency of 600 cycles a day resistance up to 25.000 N lateral pressure opening under lateral pressure still possible up to 500 N (depending on installation) specially designed security escutcheon (SEH-17 of SEH-22) available for both 17mm and 22mm cylinders available in backsets of 35mm and 60 mm restart : the lock will re-do 3 attempts to close after the first attempt when not properly locked power supply PS24D52 : 24V = direct current +/- 5%. Warranty of lock invalid if this power supply is not used! connection via removable plugs with screw clamps (wire section 1,5 mm²) B&B Locks Cable (2 x 1,5 mm² + 3 x 0,22mm²) Warranty of lock invalid if this cable is not used! Prescription text : B&B A1 Basic HE - Fail secure lock with cylinder block and handle - with small deadlocking bolt (2/3) APPLICATIONS: Doors that require permanent locking : banks, prisons, post offices, jewelry shops, computer departments, laboratories, exchange offices, etc., but where a mechanical exit using a handle or panic bar should always be possible. For fire doors it is important that when a power failure accurs when the door is open, the bolt stays retracted so the door can close, after which the bolt will be thrown out and the door will be locked. w w w. b b - l o c k s. c o m 55

Prescription text : B&B A1 Basic HE - Fail secure lock with cylinder block and handle - with small deadlocking bolt (3/3) INSTALLATION: Installation instructions and connection diagram : see documentation. When installing the lock, make sure there is a proper and spotless recess. The cylinder recess must allow easy installation of the cylinder even after the lock has been mounted. This way, there will be no tension on the base plate when the cylinder is tightened. Furthermore, make sure the clearance between the cover plate of the lock and the striker plate is at least 2mm and maximum 6mm. In case of a revolving (180 ) door, it must perfectly stop in the 0-position; a door which is not in the exact position cannot be locked. A proper floor spring with adjustable stop and 0-position is a good solution. With these doors it is advisable to provide more lateral clearance. It also goes without saying that both door and doorframe must be sufficiently rigid and that the lock must be firmly installed for correct operation. OPTIONS: Solid striker plate (6mm thick) with adjustable striker cup (a movable insert that allows adjustments : 2mm to the left and 2mm to the right). PCB protected in polyurethane casted resin against humidity, etc. & door detection by 3 Hall-sensors instead of 1 Hall-sensor. Security escutcheon with handle SEH-17 or SEH-22 (solid casted piece) fixed with 2 x M8 screws, offers a strong protection against aggression on the cylinder and gives an extra anchoring for the lock. BFB-1: Baseplate fixation blocks SMB: Surface mount bracket REL-1: Printed circuit board to transform the bolt and door signals coming from the A1- BASIC lock into potential free outputs. SRC-1: Din rail box, which translates the information coming from the A1-SRC lock and turns them into potential free outputs (position of the bolt and the door, use of the key and the handle). 56

Factory & Sales: B&B LOCKS s.a. Chemin de la Palette 1973 Nax Switzerland Tel. : +41.27.203.68.83 Fax : +41.27.203.68.85 E-mail : contact@bb-locks.com Sales office: B&B LOCKS n.v. Heidedreef 58 2970 Schilde Belgium Tel. : +32.3.326.36.30 Fax : +32.3.326.38.33 E-mail : info@bb-locks.com