www.sebury.com.cn Digital Keypad Use s Manual



Similar documents
P10 - Standalone Access Controller and Reader

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

AC-115 Compact Networked Single Door Controller. Installation and User Manual

9452/9453 Installation and User Guide

SECURITY SYSTEM ADP-CAN

How To Program An Autodialer

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

User Manual. Before installation and use, please read the user manual carefully.

WIRELESS HOME ALARM SYSTEM (WHA1)

PROXIMITY CARD READERS C-10, C-20, C60, C70


WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

Automatic Telephone Dialer TD-101(W)

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

WD-AMX Water Detection Controllers

Secure Keypads for access control

PAC1 Door Access Controller

AUTODIALLER / QUICKDIALLER - SA132

INSTALLATION GUIDE. FCC ID NOTICE

ACTIVE 5 ENGINEERING MANUAL

TS510 & TS500. Installation & User Guide. Compatible Equipment

AR-721U/721K/661U User s Guide

1R / 4-BUTTON SERIES

Operating Instructions. Keypad

How To Control A Car Alarm On A Car With A Remote Control System

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

GSM HOME SECURITY SYSTEM

Adaptability to Enhanced Security

The Child Reminder System Installation Manual

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Adaptability to Enhanced Security

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200

Installation Instructions. Thermo Call TC3

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Installation and Operating Manual

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

Auto Dialer. Manual E-921APQ E-921GPQ

MODEL DK-26 DIGITAL KEYPAD SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

Advantium 2 Plus Alarm

Autodialler. Installation & Programming Guide HYL004. Please read these instructions before you start the installation. Installation.

Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter

Using your LED Plus keypad

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

INSTALLATION INSTRUCTIONS

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

INSTALLATION/PROGRAMMING INSTRUCTIONS 928 ENTRYCHECK

PK5500 v1.1 Installation Instructions

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

GSM Autodialer Professional GJD700 Speech & Text Autodialer

Blue Point Engineering

Combi B Alarm box. Mounting instructions

9448 Installation and User Guide

CONTENTS 4. HOW TO UNSET THE PANEL...7

GERONIMO ANALOGUE HEAVY DUTY TELEPHONE

Model PBX 308 System Administration Guide

INSTALLATION GUIDE OWNER S GUIDE

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

GV- RK1352 Card Reader

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

PA4. 4 Zone Wired Intruder Alarm System. Installation & Operating Manual. MAINS CLEAR 24Hr. Zone 1 Zone 2 Zone 3 Zone 4

Add Door Phones to Your Phone System

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Shunt lock function 3066

GV-AS/EV Controller. User s Manual

User Manual (Password+RF Card+ +Mechanical Key)

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

AD-01 Slave Auto Dialer. Owner s Manual

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

Model SETR-50 and SETR-51 Trim Tab Control

FIREDEX Conventional Fire Panels

Fire Pump Controllers Remote Alarm Panels

site monitoring Kit Site Monitoring Kit User Manual we prove it.

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

Alarm Security Kit - NVR

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

Mazda CX

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

ACP10 10 Zone Intruder Alarm System

GV-AS Controller. Installation Guide

Electro-Pneumatic Bus Door Control Mechanism


Mureva Assembly surface mounted wiring devices

Business/Home GSM Alarm System. Installation and User Manual

STAND-ALONE PROXIMITY ACCESS CONTROL SYSTEM

Installation Instructions. ThermoCall TC4. Entry/Advanced

Technical Overview Add-on Sensors - Smoke Alarm. Get yours direct at:

2004 Directed Electronics, Inc. Vista, CA N426V 07-04

COLOR VIDEO DOOR PHONE CDV-71BE/D

PUSH BUTTON START INSTALLATION MANUAL

Mirror Mount Video Monitor/Recorder with Front and Rear View Night Cameras PLCMDVR5

Transcription:

K3 K4 www.sebury.com.cn Digital Keypad Use s Manual

Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming is done through the keypad. Codes and operating parameters are stored within the microprocessor and can not be lost due to power failure. Store 000 prox cards and user 4 digit codes. Each 4 digit code has 0,000 possible combinations. The unit has one relay with 2 Amp contacts. Changing Master & User Codes 7 Delete User Card OR Cards 8 User Operation Mode 8 Setting Door Relay Strike time 8 Setting Alarm Signal Output Time 9 Set Door Open Detection Time 9 Setting Security Arrangement 9 Resetting to Factory default setting 0 Changing User Password Code 0 Technical Specifications Package Listing Programmable Functions Relay latching or momentary Relay activate independently or together Change Codes master, 000 users & prox cards Door open detection Programmable Timers Door relay time 00-99 seconds Door open detection 00-99 seconds Alarm time 00-99 minutes Wiring Connections Electric lock Specifications Before the installation carefully read the manual www.sebury.com.cn

External Push Switch Magnetic Contacts Alarm Intramural Interface Circuit. Alarm output interface (See Figure ) Keypad: 2 keys R Q Programming memory: Non volatile Eeprom memory 2K Figure IMPORTANT INFORAMTION There are no user serviceable parts contained within the K3 access control keypad. 2. Electric lock interface (See Figure 2) If holes are to be drilled before mounting onto a wall, check for hidden cables and/or pipes before drilling. Use safety goggles when drilling or hammering in cable clips. Every effort has been made to provide accurate information, however slight variations can occur. We also reserve the right to make changes for product improvement at any time RELAY Figure 2 Mounting TE PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL THE K3/K4. Attach the rear plate to a single or double gang electrical box or secure to the wall firmly with at least three flat head screws. 2. When wiring has been completed, attach the front cover to the rear plate. 2 www.sebury.com.cn www.sebury.com.cn 3

The front cover can be permanently secured by using the short screw supplied K3/K4 Wiring Unplug the cable harness and connect the necessary cables, (See Figure 5). showed as Figure 6 for special power Supply connections, this power will make controller work stablly. Tape any wires that are unused. Plug the cable harness, (See Figure 5) Attach the front cover, (See Figure 3). K3 Figure 3 J 2V D _ IN K4 OPEN BELL BELL2 Terminal Wire Connector Function 0 Bell2 Green Not Connect 9 Bell White Not Connect 8 Grey Alarm 7 OPEN Yellow To Door Remote Control Button Then Negative 6 D_IN Brown To Door Contact Then To Door In 5 2V Red (+) 2Vdc Positive Regulated Power Input 4 Black (-) Negative Regulated Power Input 3 Blue Door Strike Relay N/O 2 Purple Door Strike Relay Orange Door Strike Relay N/C K3 SW3 Printed Circuit Board Figure 4 À²ð ª¹Ø ³õʼ» Å 2 3 J3 RST K4 Warning! N4007 is necessory,otherwise the controller doesn't work stablly. Do not plug adapter our transformer into mains until all wiring has been completed and the front cover secured. 4 www.sebury.com.cn www.sebury.com.cn 5

common power supply connection BELL2 BELL OPEN D_IN +2V Green White Grey Yellow Brown Red Black Blue Purple Orange Figure 5 Power Supply +2V Annunciator External Push Switch Door Status Inspector Electric Rim Lock Electric Door Bolt Power Up After all wiring is complete and the unit face plate is attached to the back plate, apply 2Vdc power to the unit. READY LED (the red LED) lighting on, ACCEPT LED(the yellow LED) flashing at K3. READY LED(the red LED) lighting on, ACCEPT LED(the red LED) flashing at K4. Engineer Programming Mode To enter programming mode Press: 9999 # within 5 seconds, Ready(the green LED) and * Accept LED illuminated, Open LED flashing. Note Press: # to save changes and exit engineer programming, when all programming has been completed otherwise changes will not be saved. special power connection BELL2 BELL OPEN D_IN +2V Green White Grey Yellow Brown Red Black Blue Purple Orange Special Power Supply Annunciator +2V/A External Push Switch Door Status Inspector Electric Rim Lock Electric Door Bolt +2V/3A 2 Changing Master & User Codes In engineer programming mode: To change Master code Press: 0 new master code # re-enter new master code # Upon acceptance Open LED illuminates and stops flashing. Press # after changing the master code, otherwise unit will disregard the new code and revert back to the factory default code. Note: the master code must be 4-8 digit number. Figure 6 Adding User Codes & Cards 6 www.sebury.com.cn www.sebury.com.cn 7

To Add User cards & codes Press: read card user identification # Note: the user identification must be 3 digit number, if adding more than card, read the next card after inputting the 3 digit code for the previous card, when you have finished adding all cards press the # key. st card must be 000 up to 999. Then the K3/K4 control station added a user card it was auto added a user code with 234. Delete User Card or Cards There are 3 options to delete a user card or cards, in engineering mode. A.) Press: 2 0 0 0 0 # to delete all user cards b.) Press: 2 read card # to delete individual user card c.) Press: 2 user identification number # to delete individual user card User Operation Mode There are 3 different options for user operation mode, card only, card and password, valid code. The optioned used is common to all users. Press: 3 0 0 # valid card only Press: 3 0 # valid card and password Press: 3 0 2 # valid card or passwor Setting Door Relay Strike Time The door relay output can be operated as either normally opened or normally closed, a maximum current of 3 ampere can pass through the relay if used as normally opened or 2 ampere if normally closed. The door relay time can be set from 0 seconds to a maximum of 99 seconds. The factory default setting is 6 seconds and can be changed through the keypad. Press: 4 new time from 00-99 seconds # Setting Alarm Signal Output Time Press: 5 new time from 00-99 minutes # Setting Door Open Detection Press: 6 00 # to disable this function (factory setting) Press: 6 0 # to enable this function. In order for this feature to work, door contacts must be connected. There are 2 programming functions that work together in this mode. a.)if door not closed after opening, keypad buzzer sounds. B.)If door forced open, keypad buzzer sounds and sends alarm signal. Setting Security Arrangement There are two levels of keypad security available for the K3/K4. Press: 7 0 # to read 0 invalid cards or valid cards, then enter 4 wrong passwords in succession, the keypad is locked for 0 minutes. 8 www.sebury.com.cn www.sebury.com.cn 9

Press: 7 0 2 # to read 0 invalid cards or valid cards, then enter 4 wrong passwords in succession, the keypad activates and alarm signal. To disable this feature: Press: 7 00 # factory default setting. Resetting To Factory Default Setting To revert all settings to the factory default values then the Non Volatile Memory (Eeprom) must be reset. Reset Non Volatile Memory by switching of the power and placing the jumper connector onto the pins & 2 as per figure 4. After switching power on remove jumper, the K3/K4 will give a beep and is now reset to factory default values. DC Supply Voltage Current Consumption Door Relay Alarm output load Tamper Protection Codes Keypad Card Types Induction Distance Wiring Connections Memory Operating Temperature Keypad Housing Dimensions Weight Technical Specification Low voltage input 2 0% Vdc unregulated 00mA @ quiescent 2Amp 2Vdc 50mA pull current Negative loop, normally closed Master, 000 cards and 000 codes. K3(2 keys, 3 LED status indicators) K4(2 keys, 2 LED status indicators) EM or EM compatible 5-0cm Electric lock Remote door control Door open detection External Alarm Non volatile Eeprom memory -20 to 60 ABS+PC K3(90mm 60mm 27mm) K4(20mm 50mm 27mm) 00g Changing User Password Code The factory default setting for each user password code 234, this can be modified so that each user has a unique individual 4 digit code. Press: read user card user passoword # new password * # re-enter new password # Using Password Code to release the door Press: user passoword # Name Digital Keypad User Manual Cable Security Screws Screwdriver Pastern Stopper Self Tapping Screws Diode Package Listing Model no. K3/K4 3mm 0Pin 2mm 6mm 27 mm 3.5mm 27 mm N4007 Quantity 4 4 Remark Used for front case and back case (spare) Used for fixing Used for fixing Used for lock 0 www.sebury.com.cn www.sebury.com.cn