2012 San Francisco Colloquium



Similar documents
Recent Siemens HVDC Activities Yuriy Kazachkov Siemens PTI

Introduction to The Trans Bay Cable Project

HVDC-VSC: transmission technology of the future

POWER TRANSMISSION FROM OFFSHORE WIND FARMS

Magnus Callavik, ABB Power Systems, HVDC, Västerås, Sweden Phone: +46(0)

Topics. HVDC Fundamentals

DC TRANSMISSION BASED ON VOLTAGE SOURCE CONVERTERS

Explosion proof housings for IGBT module based high power inverters in HVDC transmission application

HVDC PLUS and SVC PLUS: Reliable and Cost-effective Power Transmission Solutions with Modular Multilevel Converters

factsheet High Voltage Direct Current electricity technical information

2012 San Francisco Colloquium

Voltage Source HVDC Overview Mike Barnes Tony Beddard

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

HVDC Light, a tool for electric power transmission to distant loads

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

EMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID

Submarine Cable Power Transmission using DC High-Voltage Three-Level Converters

COMPARISON OF THE FACTS EQUIPMENT OPERATION IN TRANSMISSION AND DISTRIBUTION SYSTEMS

factsheet High Voltage Direct Current Electricity technical information

Knowing the FACTS. FACTS that enhance power quality in rail feeder systems

Project description. Power Electronics for Reliable and Energy efficient Renewable Energy Systems

Smart Grid and Renewable Energy Grid Integration. Jian Sun, Professor and Director Department of ECSE & Center for Future Energy Systems

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

Offshore Platform Powered With New Electrical Motor Drive System

HVDC Technology for Large Scale Offshore Wind Connections

FACTS. Solutions to optimise network performance GRID

A Design of DC/DC Converter of Photovoltaic Generation System for Streetcars

Asia Pacific Regional Power Quality Seminar March 2005, Marriot Putrajaya, Malaysia. Voltage Source Converter based Power Quality Solutions

Transmissão em Corrente Contínua em Ultra-Alta Tensão

WIND TURBINE TECHNOLOGY

HVDC PLUS Basics and Principle of Operation Answers for energy.

Control Development and Modeling for Flexible DC Grids in Modelica

FREQUENCY CONTROLLED AC MOTOR DRIVE

CO-ORDINATION OF PARALLEL AC-DC SYSTEMS FOR OPTIMUM PERFORMANCE

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

Product Data Bulletin

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

Introduction. Harmonics and IEEE 519 Page 1 of 19

Renewable Energy Applications: Photovoltaic and Wind Energy Conversion Systems (WECS)

Relationship between large subject matter areas

High-Megawatt Converter Technology Workshop for Coal-Gas Based Fuel Cell Power Plants January 24, 2007 at NIST

A MULTILEVEL INVERTER FOR SYNCHRONIZING THE GRID WITH RENEWABLE ENERGY SOURCES BY IMPLEMENTING BATTERY CUM DC-DC CONERTER

Fundamentals of Power Electronics. Robert W. Erickson University of Colorado, Boulder

Principles of Adjustable Frequency Drives

HVDC 2000 a new generation of high-voltage DC converter stations

Renewable Energy Grid Integration

Electrical Considerations for HVDC Transmission Lines. Joe Mooney, PE

Cost Benefit Methodology for Optimal Design of Offshore Transmission Systems

SVC LIGHT: A POWERFUL MEANS FOR DYNAMIC VOLTAGE AND POWER QUALITY CONTROL IN INDUSTRY AND DISTRIBUTION.

The design and performance of Static Var Compensators for particle accelerators

Alternate Arm Converter Operation of the Modular Multilevel Converter

HIGH FREQUENCY TRANSFORMER WITH TRANSFORMER SWITCHOVER

Brochure Introducing HVDC

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Summary of Electric Transmission Assessment Report

General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System

HVDC Light and development of Voltage Source Converters

STATCOM Application at VELCO Essex Substation

Case Studies in On-Line Measurement of PD in Motors Fed by Voltage Source PWM Drives

7-41 POWER FACTOR CORRECTION

Design and Simulation of Soft Switched Converter Fed DC Servo Drive

B4-102 CROSS SOUND CABLE PROJECT SECOND GENERATION VSC TECHNOLOGY FOR HVDC

Reactive Power Generation by DFIG Based Wind Farms with AC Grid

The Different Types of UPS Systems

Requirements for Offshore Grid Connections. in the. Grid of TenneT TSO GmbH

Power Transmission and Distribution. Shunt reactors for medium and highvoltage. From development to use

Kinetic energy recovery on railway systems with feedback to the grid

Low Frequency AC Transmission System

Development of Novel Power Electronic Topologies for the Integration of Battery Energy Storage in FACTS Devices

ELECTRONIC POWER SYSTEMS

(2) Words and expressions used and not defined in these regulations but defined in the Act shall have the meaning assigned to them in the Act.

MINISTERIE VAN ECONOMISCHE ZAKEN GENERAL COST COMPARISON BETWEEN UNDERGROUND CABLES AND O.H. LINE SYSTEMS FOR H.V. TRANSMISSION

Philosophy of Topology and Components Selection for Cost and Performance in Automotive Converters.

Simulation and Analysis of PWM Inverter Fed Induction Motor Drive

Modeling Grid Connection for Solar and Wind Energy

AN ISOLATED GATE DRIVE FOR POWER MOSFETs AND IGBTs

OFFSHORE WIND FARM ELECTRICAL CONNECTION OPTIONS. W.Grainger 1 and N.Jenkins 2 SYNOPSIS

ENERGY AND ENVIRONMENTAL SAVINGS IN STEEL MAKING BY MEANS OF SVC LIGHT

Application Note AN-11001

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

ABB PSPS Erich Steinmann; Generator control-2013

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

Voltage Stability Improvement using Static Var Compensator in Power Systems

PB POWER ISLAND OF IRELAND CAVAN-TYRONE AND MEATH-CAVAN 400KV PROJECTS PRELIMINARY BRIEFING NOTE OVERHEAD AND UNDERGROUND ENERGY TRANSMISSION OPTIONS

Line Reactors and AC Drives

Multi-Level Inverters

UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES

Cost Benefit Methodology for Optimal Design of Offshore Transmission Systems

Development of Power Supply System with Hybrid Turbocharger for Marine Application

Power Supplies. 1.0 Power Supply Basics. Module

Basics of Electricity

Power Quality For The Digital Age INVERTING SOLAR POWER A N E N V IRONME N TA L P OT E N T I A L S W HI T E PA PER

Grid Interconnection of Renewable Energy Sources Using Modified One-Cycle Control Technique

PRECISION CAPACITOR CHARGING SWITCHING POWER SUPPLIES

Design and Applications of HCPL-3020 and HCPL-0302 Gate Drive Optocouplers

Power Quality. Uninterruptible Power Supply

What Is Regeneration?

Design a Phase Interleaving PFC Buck Boost Converter to Improve the Power Factor

Transcription:

2012 San Francisco Colloquium http : //www.cigre.org HVDC and Power Electronic Systems for Overhead Line and Insulated Cable Applications B4-8 Trans Bay Cable A Breakthrough of VSC Multilevel Converters in HVDC Transmission J. DORN, H. GAMBACH, J. STRAUSS, T. WESTERWELLER Siemens AG Germany J. ALLIGAN TBC LLC USA SUMMARY Trans Bay Cable is the first HVDC VSC scheme in the world which is based on modular multilevel converter (MMC) technology. Compared to two- and three-level topologies, which had been the standard for many years, the introduction of the innovative MMC topology has induced significant improvements and set groundbreaking milestones in HVDC transmission. Low switching frequencies of the power semiconductors led to a considerable reduction of station losses. Due to the almost sinusoidal converter a.c. voltage and current waveforms special measures, such as extensive shielding and filtering, are no longer necessary to cope with the previously associated harmonic requirements. Less engineering, less space requirements and significant improvements in audible noise emission are some further advantages. Since the MMC topology is easily scalable towards higher voltages it has also paved the way of VSC technology towards transmission power in the range of up to 1000 megawatts and more. The commercial operation of Trans Bay Cable started in November 2010. The paper covers operational experiences such as evaluation of station losses, harmonic performance and fault ride through capability. With introduction of the MMC technology for grid access of offshore wind farms additional requirements arose, such as higher d.c. current capability and stricter grid code specifications. Further development aspects of the converter design to cope with these new requirements are presented. KEYWORDS Trans Bay Cable HVDC Voltage Sourced Converter Modular Multilevel Converter MMC AUTHOR EMAIL joerg.dorn@siemens.com

1 First Application and Converter Principle The Trans Bay Cable link is the first HVDC PLUS system in the world, based on modular multilevel converter (MMC) technology. Since November 2010 the link is in commercial operation and transmits up to 400 MW of real power from Pittsburg in the East Bay to Potrero in the centre of San Francisco (Fig. 1). It covers a distance of 85 km right across the bottom of the San Francisco Bay. The reactive power capability is +/- 300MVar, limited down to +/- 170 MVAr at rated real power transfer on Potrero station and +/- 145 MVAr on Pittsburg station, respectively. The DC link voltage is +/- 200 kv. Fig. 1: Trans Bay Cable Link, San Francisco, USA The basic topology of the modular multilevel converter (MMC) and its generic design are shown in Fig. 2. An MMC consists of six phase arms. Each of these comprises of several submodules (SM) and one converter reactor connected in series. Each submodule comprises of an IGBT half bridge and a submodule capacitor for energy storage purposes. The latter ensures a low inductive commutation of the semiconductors within one submodule. With individual control of the submodules each phase arm can be operated as controlled voltage source and sinusoidal a.c. voltages and smooth d.c. voltages be achieved [1], [2]. SM U d Phase Unit Fig. 2: HVDC PLUS - Basic scheme 1

2 Operational Experience 2.1 Converter Control Performance Fault Ride Through Capability The Trans Bay Cable Converters have demonstrated an excellent fault ride through (FRT) behavior in many situations during commissioning and commercial operation. They provide continuous variable active and independent reactive power for control purposes in a very smooth and, if necessary, high dynamic way. Fig. 3 shows an example of the response to an a.c. under-voltage caused by a phase to phase fault event, which occurred on March 18 th, 2011 in Potrero (inverter). Fig. 3: Fault ride through behavior of Trans Bay Cable MMC Converter, a.c. line-to-ground voltages (top), phase arm currents (middle), AC converter currents (bottom) Inner Converter Control Variables The basic control principle of modular multilevel converters was described in the past [1]. Important converter control variables, beside voltages and currents, are for e.g. the inner phase arm energies w kz, i.e. the energy stored in submodule capacitors of each phase arm. The index k 1, 2, 3 is related to the converter phases, index z p, n describes the upper, lower phase arms, respectively. Converter Zweigenergie Arm Energies w [pu] (normalized) 1 0,95 0,9 0,85 0,8 0,75 0,7 0,65 0,6 0,05 0,07 0,09 0,11 0,13 0,15 0,17 0,19 0,21 0,23 0,25 Time (sec) Fig. 4: Measured phase arm energy (normalized) {w 1p, w 2p, w 3p, w 1n, w 2n, w 3n } Vertical Balancing of one phase (left) and Horizontal Balancing (right) Converter Zweigenergien Arm Energies w [pu] (normalized) 1 0,95 0,9 0,85 0,8 0,75 0,7 0,65 0,6 0,25 0,27 0,29 0,31 0,33 0,35 0,37 0,39 0,41 0,43 0,45 Time (sec) 2

Of course the energy of all series connected capacitors within each phase arm has to be balanced. But in addition to that, the phase arms have to be balanced vertically and horizontally in terms of their energy w 1p, w 2p, w 3p, w 1n, w 2n, w 3n, as well. Fig. 4 shows the excellent step response of the converter control with respect to the phase arm energies [3]. It s worth mentioning that the a.c. converter currents are not influenced by the balancing control. Harmonics Due to the high number of series connected power modules within one phase arm, the MMC concept results in almost linear control capability. Each phase arm acts as a quasi continuous voltage source. Harmonic distortion as a result of the switching of single power modules are therefore of minor importance. Harmonic filters have become a thing of the past on the AC side as well as on the DC side. The measuring results shown in Fig. 5 were performed during the commissioning period of the scheme. The frequency range under consideration is from 120 Hz to 3 khz for a.c. voltage distortions and from 60 Hz to 5.1 khz for d.c. current distortions. The fluctuations are caused by a variation of real and reactive power. Fig. 5: Harmonic Interference Levels Pittsburg Conv. Station total harmonic distortion of converter a.c. voltages (top) d.c. equivalent disturbing current (bottom) Feb. 1 st, 2010 2.2 Losses Converter losses are very important in the field of energy transmission. The MMC technology has led to a significant reduction of losses compared to two or three level converters concepts. The main reason is that two or three level converters work with considerably higher switching frequencies in the order of one kilohertz compared to 100 to 200 Hz for MMC. 3

Actual system losses, including cable losses of the Trans Bay Cable project are determined by direct measurement. As the station auxiliary power demand is drawn from the tertiary windings of the converter transformers, this demand is included in the measured results (Fig. 6). The fluctuation of the losses corresponds to the variation of the reactive power, as depicted in the bottom of Fig. 6. Fig. 6: Systems losses (top) and reactive power (bottom) as a function of time 3 Further Development Aspects As shown in Fig. 1 the MMC topology consists of phase arms with a series connection of submodules, each of them consisting of an IGBT half bridge and a submodule capacitor. The main aspects of current developments are to increase the power capability of the submodules, to reduce losses and to investigate alternative configurations instead of half bridges. 3.1 Half Bridge Submodules Since the introduction of the MMC topology requirements to increase the transmission power arose from the market. As an example, in Germany several large offshore wind farms are already under construction and further clusters with a capacity of more than ten giga watts are in a planning stage. For most of these installations HVDC is the only solution to transmit the power to the shore, requiring a transmission power of up to one giga watt and more per system. Due to the limitation of the d.c. voltage capability of the XLPE cables, the required d.c. current increase in a range of up to 2 ka. A single IGBT module of the industrial standard type in the voltage class of 4.5 kv does not have such a current capability. Therefore a parallel connection of IGBTs within the submodule is the most reasonable and economic solution to fulfill these requirements. IGBTs Fig. 7: Half bridge submodule design with parallel connections of 4

The parallel connection of IGBTs can easily be handled because the saturation voltage has a positive temperature coefficient in a wide current range and ensures good current sharing of the devices. Apart from power transmission applications the parallel connection of IGBTs has successfully been employed for many years, e.g. in traction drives. 3.2 Full Bridge Submodules For static var compensation full bridge modules (FB-SM) were developed. With a series connection of these full bridge submodules connected between the three phases, the topology was introduced as SVC PLUS some years ago as a containerized solution. If the full bridge submodules are arranged in a B6 configuration, an alternating voltage can be generated instead of a d.c. voltage. This topology was introduced by Siemens for static frequency converters (SFC PLUS) to exchange power between the national three phase grid (50 or 60 Hz) and the single-phase railway grid operated with 16 2/3 Hz. Fig. 8: Full bridge submodule (FB-SM) Utilizing full bridge submodules in a B6 configuration could also be used for HVDC. In that case, a short circuit between the d.c. poles does not lead to a fault current driven from the grid because the current can be turned off immediately with the IGBTs. In some cases this might be advantageous compared to half bridge submodules, where the a.c. circuit breaker has to be opened to clear the fault. However, the utilization of full bridge submodules causes higher losses of the converter, since the phase arm current has to flow through two instead of one power semiconductor in case of half bridge power modules. 3.3 Submodule with d.c. Short Circuit Turn-Off Capability The clamp-double submodule (CDSM) offers higher efficiency than the full bridge submodule including the capability to turn off a d.c. fault current. It has double the voltage capability compared to full bridge submodules and has therefore to be compared with two full bridge submodules in series. The voltage output of the CDSM is 0; U C or 2 U C but the current flows through only three semiconductors during steady state operation. During normal operation, the IGBT in the centre of the module is always turned on, only in case of a short circuit + + between the d.c. poles of the converter that IGBT has to U c U c - - be turned off and the d.c. fault can be cleared without opening of the a.c. circuit breaker. Fig. 9: Clamp-double submodule (CDSM) However, the losses of a converter equipped with this kind of submodules dissipates higher losses than a converter with half bridge modules and might therefore be of interest for overhead line applications only. 3.4 DC Chopper Submodule When offshore wind farms are connected to the onshore power grid, utilities demand compliance to stringent requirements regarding fault ride through capability as per grid code. One of the requirements is that in case of an a.c. line fault in the onshore power grid the offshore wind farm must not be turned off immediately. Typically there are requirements that if the a.c. fault is cleared within about one second the HVDC converter has to restore the power transmission within some ten to hundred milliseconds. This means, in case of an onshore a.c. fault the wind turbines and the HVDC transmission has to be kept in operation for up to two seconds. The transmitted energy has to be 5

dissipated during this fault time. This can be achieved by dynamic braking chopper in the HVDC inverter station. A series connection of the braking chopper submodules are connected between the d.c. poles on the inverter station and absorb the transmitted energy, if necessary. Fig. 10: Braking chopper submodule 3.5 Submodules with an Internal Series Connection of Semiconductors It is obvious, that in all of the presented submodule types a series connection of several semiconductors can be realized. In case of the half bridge submodule, the basic configuration is shown in Figure 11. Compared to the previous half bridge submodule a semiconductor fault usually does not lead to a discharge of the submodule capacitor because the remaining healthy devices should be able to block the applied voltage. However, some aspects should be considered: A faulty semiconductor has to have the capability to carry the full submodule current. That might be critical since IGBT devices consist of an internal parallel connection of small chips. If one chip fails the full load current flows through the faulty chip which might cause an overheating of the silicon or the internal connection to the chip. One possibility to overcome that challenge is to apply a bypass device for each semiconductor. The voltage of the half bridge submodule with one or two faulty devices bridged has to be reduced accordingly to ensure that the devices are operated within their specified voltage limits. However, if the voltage is decreased linear with faulty devices per submodule the remaining semiconductors are stressed higher because the effective stray inductance per healthy semiconductor became higher. Additionally it shall also be considered that a short circuit of a whole half bridge can occur. This might happen as a result of a failure in the control system or of semiconductor failures with a domino effect in the series connection. In that case the fault current would be in the order of several hundred thousand amps and the mechanical design of the submodule should be capable to handle that fault current without excessive impact to the neighbored submodules accordingly. Multilevel concepts with internal series connection of IGBTs utilize the blocking capability of the semiconductors in a reduced way and the switching frequency is typically higher to achieve the same performance. Therefore the losses of multilevel concepts with internal series connection of IGBTs are expected to be higher compared to topologies without series connection Fig. 11: Half bridge submodule with internal series connection of semiconductors REFERENCES [1] Marquardt, R.; Lesnicar, A.: New Concept for High Voltage-Modular Multilevel Converter, PESC Conference, Aachen, Germany, 2004 [2] Dorn, J.; Huang, H.; Retzmann, D.: Novel Voltage-Sourced Converters for HVDC and FACTS Applications, Cigré Symposium, Osaka, Japan, 2007 [3] Armonies, U.; Dommaschk, M.; Retzmann, D.; Würflinger, K.: VSC Based HVDC with Modular Multilevel Technology in Praxis, ETG-Kongress, Würzburg, Germany, 2011 6