Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide



Similar documents
Intel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide

MegaRAID LSIiBBU08 Intelligent Battery Backup Unit. Quick Installation Guide

MegaRAID LSIiBBU09 Intelligent Battery Backup Unit

MegaRAID SAS i and SAS i RAID Controllers

Intel NUC Kit DC3217IYE User Guide. Intel NUC Kit DC3217IYE

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Replacing the Gateway M320 Keyboard

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

Replacing the Gateway M675 Keyboard

Small form factor bay converter and hard drive installation

Packard Bell Easy Repair 1. Packard Bell Easy Repair

Processor Cage Fans, Front and Rear Replacement Instructions

Replacing Redundant AC Power Supplies in an EX4500 Ethernet Switch Without Disrupting Service

Set Up Your MXI -Express x1 System

Compaq Presario Desktop Products. Upgrading and Servicing Guide

StorTrends 3400 Hardware Guide for Onsite Support

HP ProLiant DL165 G7 Server. Installation Instructions

HP SATA/SAS hard drive and Solid State Drive installation

Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S

Front Panel Board Cable Replacement Instructions

Service Guide. Gateway M275

Wall-Mounting your HP computer. User Guide

Upgrading and Servicing Guide

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

HP UPS R1500 Generation 3

NVIDIA Graphics Card and Driver Installation Guide (Windows NT 4.0 and Windows 2000)

Set Up Your MXI -Express x4 System

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

SERVICE GUIDE. Gateway Notebook

Hard Disk Drive (HDD)

Memory Modules User Guide

EasyNote TJ Series. Disassembly Manual

This guide explains how to install an Intel Solid-State Drive (Intel SSD) in a SATA-based desktop or notebook computer.

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

4x3.5" Hot-Swap Drive Cage Kit Installation Guide for Intel Server Chassis/System

Rack Mount Kit Install Guide: Intel Entry Server Chassis SC5295-E UP/DP/WS/BRP Intel Entry Server Chassis SC5299-E DP/WS/BRP

Dell Inspiron 660s Owner s Manual

Changing the SIM in a BANDIT Product s GSM Card

4RU High Density Shelf Installation Instructions

UPGRADING AND SERVICING GUIDE

Installation Guide. Wyse Z Class 2 and 4-GB RAM Upgrade Option Kit. Products: Z90DW, Z90SW, Z90D7, Z90S7. Issue: PN: L Rev.

High Density RocketRAID Rocket EJ220 Device Board Data RAID Installation Guide

Accessing the printer system board

Tyan Computer. Transport PX22. Service Engineer s Manual

Installing your upgrade processor

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

SuperLoader 3. Quick Start Guide. Installing the Autoloader 0

HP 22-in-1 Media Card Reader

Packard Bell Easy Repair

apple Service Source PowerBook G4 (DVI) Updated 4 December Apple Computer, Inc. All rights reserved.

RS Monitor Backlight Replacement

HP Laser Jet 2400 Series Fixing Drive Side Plate Assembly Fixing Drive Side Plate Assembly- RM page 1

TS-x53 Pro, SS-x53 Pro, TS-651, TS-851, TS-x69 series (2/4/5/6/8-bay)

Inspiron 13. Service Manual Series. Computer Model: Inspiron Regulatory Model: P57G Regulatory Type: P57G001

Rail Kit Install Guide: Intel Modular Server System MFSYS25 A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products

Inspiron 15. Service Manual Series

3-Port FireWire 800/400 PCI Host Card

Installing the Video Input and TV Tuner Cards in a Compact Computer or a Dual PCI-Slot Tower Computer

Installing Your 960 or 980 Server into a Rackmount Cabinet

FUSION R400 RAID USB 3.0

430 Power/Electronics Replacement

Removing memory and option cards

About the BitStorm 6051 POTS Splitter

TeamPoS 2000 Installation Instructions Upgrade to M Motherboard

Rack installation instructions

Chapter 2 Installation

HP Optical Bay Hard Drive Bracket

Installation Guide. Wyse C Class 2-GB RAM Upgrade Option Kit. Issue: PN: L Rev. A

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

Power Supply Guide Version 1.0 for D-Show

HP LaserJet MFP Analog Fax Accessory 300 Fax Guide

HP Integrity rx2660 Server Installation Guide

ProLiant DL380 Generation 2 Server Maintenance and Service Guide

Memory Installation Guide

5800 Temperature Sensor Cable Assembly

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

In this section we tell you how to set the fault mode selection plug, key your I/O chassis, install your module and make your wiring connections.

Upgrading or Replacing a Host Interface Card in a Xanadu-230 Controller-Drive Tray

Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: PN: L Rev. A

About the HotWire Slot Standalone Shelf

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

Memory Modules. Document Part Number: This guide explains how to replace and upgrade memory in the computer. May 2006

Mazda CX

Memory Modules. Document Part Number: This guide explains how to replace and upgrade memory in the computer.

Installation Guide. Wyse C Class Conversion to WES7. Wyse USB Firmware Tool TM Release Issue: PN: L Rev. B

MCR1900 Media Converter 19-Slot Chassis

HP R12000 and R18000 DirectFlow UPS User Guide

BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES

RM410. Hardware Installation Guide. Quick Start Guide. Rack Mounting Kit. Version 1.00 Edition 1, 12/2012

How To Install Superserver X9 2U Twin With A 2U 2U (Powerclock) And 2U 1 (Powerboard) 2U-Dtf (Powerstation) 2Us 2U Twins (Powerwin) 2Un

Dell P Series Monitor VESA Mounting Bracket Installation Instructions

Intel SC5100 Pedestal and Rack Server Chassis Subassembly Product Guide

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

Triple Threat 3-in-1 Game Table 3 IN 1 GAME TABLE

MaxAttach NAS 4000 Series OS 2.2 Hard Disk Drive Replacement

Installation Instructions

Transcription:

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide Thank you for buying an Intel RAID Maintenance Free Backup Unit 4. The Intel RAID Maintenance Free Backup Unit 4 supports the Intel RAID Controller RS3DC040 and RS3DC080. The following information will help you assemble your Intel RAID Maintenance Free Backup Unit 4 and install components. Perform all installation work at an electrostatic discharge (ESD)-safe workstation that meets the requirements of EIA-625, Requirements for Handling Electrostatic Discharge Sensitive Devices. You must perform all actions in accordance to the latest revision of the IPC-A-610 ESD-recommended practices. This guide and other supporting documents are located on the web at: http://www.intel.com/support. H24048-001

(This page is intentionally left blank.)

Table of Contents Product Overview... 1 General Installation Process... 2 Unpack the RMFBU4 Module... 2 Prepare the Host Computer... 2 Remove the RAID Controller from the Computer... 2 Attach the RMFBU4 Module to the RAID Controller... 2 Install the Clip on the Remote Mount Board... 3 Attach the Super Capacitor Pack Module to the Clip... 3 Connect the RMFBU4 Module to the Remote Super Capacitor Pack Module (Valid for Remote Mount Board)... 4 Reinstall the RAID Controller on the Motherboard (Valid for Remote Mount Board)... 4 Install the Remote Mount Board on the Motherboard... 5 Mount the Super Capacitor Pack Module to the Intel Server Chassis...5 Connect the RMFBU4 Module to the Remote Super Capacitor Pack Module (Valid for Intel Server Chassis)... 6 Reinstall the RAID Controller on the Motherboard (Valid for Intel Server Chassis)... 6 Reference Documents... 7 i

Warning Warning Caution Tools Required Read all caution and safety statements in this document before performing any of the instructions. Also see the Intel Server Board and Server Chassis Safety Information document at: http://www.intel.com/support/ motherboards/server/sb/cs-010770.htm for complete safety information. Installation and service of this product to be performed only by qualified service personnel to avoid risk of injury from electrical shock or energy hazard. Observe normal ESD [Electrostatic Discharge] procedures during system integration to avoid possible damage to server board and/or other components. Phillips* screwdriver Anti-static wrist strap Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the property of others. Copyright 2013, Intel Corporation. All rights reserved. ii

Product Overview The Intel RAID Maintenance Free Backup Unit 4 (RMFBU4) is an Open NAND Flash Interface (ONFI) flash module that provides cache off-load capability to protect cached data in case of host power loss or server failure. The RMFBU4 module connects to a Super Capacitor Pack module, which provides power for the backup of your data. The RMFBU4 module attaches directly to the RAID controller, and then it connects by cable to a Super Capacitor Pack module that is attached to a remote mount board or an Intel Server Chassis. The following figure shows the front view and the back view of the RMFBU4 module. The front view is the side that you can see when the unit is installed on a RAID controller. J1 Connector H2-25444-041 SN : SR228P0365 ABCD J2 Connector Front View Back View J1: 9-pin Connector to the Remote Super Capacitor Pack Module J2: 70-pin Board-to-Board Connector 1

General Installation Process 1 Unpack the RMFBU4 Module CAUTION: It is good practice to back up your data before adding hardware, such as an RMFBU4 module, to your system. Unpack the RMFBU4 module in a static-free environment. Remove the module from the antistatic bag, and inspect it for damage. If the module appears to be damaged, contact Intel or your reseller support representative. 2 Prepare the Host Computer CAUTION: Before you install the RMFBU4 module, make sure that the host computer is disconnected from the power and from any networks. 4 Attach the RMFBU4 Module to the RAID Controller A Ground yourself, and make sure that the system is grounded. B Place the RMFBU4 module front-side-up on a flat, clean, static-free surface. C Mount the two standoffs on the front side of the RAID controller by screwing in two screws from the back side of the RAID controller, as shown in the following figure. The standoffs are threaded at both ends, and the screws thread from the back side of the RAID controller into the board-to-board standoffs. Center the screwdriver carefully to avoid stripping the screw heads. Do not over-tighten the screws. D Hold the RMFBU4 module so that the front side faces upward, and align the J2 connector on the RMFBU4 module with the connector on the RAID controller. J2 Connector J4B1 Connector RMFBU4 Turn off the host computer, and unplug the power cords from the rear of the power supply. Remove the cover from the host computer to permit access to the RAID controller. Intel RAID Controller RS3DC080 as shown 3 Remove the RAID Controller from the Computer A Unplug all cables from the RAID controller, remove the screw that attaches the bracket to the computer chassis, and carefully remove the RAID controller from the slot. F Secure the RMFBU4 module to the RAID controller by screwing in the two screws from the top side of the RAID controller. The standoffs are threaded at both ends, and the screws thread from the back side of the RAID controller into the board-to-board standoffs. Center the screwdriver carefully to avoid stripping the screw heads. Do not over-tighten the screws. E Carefully press the RMFBU4 module onto the RAID controller so that the two connectors are firmly joined. B Place the RAID controller on a flat, clean, static-free surface. NOTE: If the Super Capacitor Pack module is to be attached to a remote mount board, continue to follow the steps 5 to 9. If the Super Capacitor Pack module is to be attached to an Intel Server Chassis, continue to follow the steps 10 to 12. 2

General Installation Process 5 Install the Clip on the Remote Mount Board A Ground yourself, and make sure that the system is grounded. B Place the clip and the remote mount board module front-side-up on a flat, clean, static-free surface. C Hold the clip so the screw holes on the clip line up with the screw holes on the remote mount board, as shown in the following figure. 6 Attach the Super Capacitor Pack Module to the Clip A Ground yourself, and make sure that the system is grounded. B Place the Super Capacitor Pack module and the clip front-side-up on a flat, clean, static-free surface. C Press the Super Capacitor Pack module into the clip until the module clicks firmly into place, as shown in the following figure. Clip A A A Clip A Super Capacitor Pack module D Secure the clip to the remote mount board in three screw holes with the screws and the nuts. E The screws thread through the front of the clip and the remote mount board. Center the screwdriver carefully to avoid stripping the screw heads. Do not over-tighten the screws. 3

General Installation Process 7 Connect the RMFBU4 Module to the Remote Super Capacitor Pack Module (Valid for Remote Mount Board) 8 Reinstall the RAID Controller on the Motherboard (Valid for Remote Mount Board) A Ground yourself, and make sure that the system is grounded. B Place the RAID controller on a flat, clean, static-free surface. C Remove the cable that is included in the RAID controller box. D Insert one 9-pin cable connector on the cable into the 9-pin J1 connector on the RMFBU4 module, as shown in the following figure (the cable is blue). E Insert the other 9-pin cable connector into the 9-pin connector on the remote Super Capacitor Pack module. Align the cable connectors to make sure that they are connected correctly. A Make sure that the power to the chassis is still turned off, the power cords are unplugged, and the chassis is grounded and has no AC power. B Install the RAID controller in a PCIe slot on the motherboard, as shown in the following figure. NOTE: This RAID controller is a PCIe x8 card, and it can operate in x8 or x16 slots. Some PCIe slots, however, support only PCIe graphics cards; if a RAID controller is installed in one of these slots, the RAID controller will not function. Refer to the guide for your motherboard for information about the PCIe slot. C Press down gently, but firmly, to seat the card correctly in the slot. D Secure the RAID controller to the computer chassis with the bracket screw. Super Capacitor Pack module Remote Mount Board Bracket Screw Super Capacitor Pack module Remote Mount Board J1 RMFBU4 module RMFBU4 module Press Here Press Here Intel RAID Controller RS3DC080 as shown Edge of Motherboard PCIe Slot Intel RAID Controller RS3DC080 as shown 4

General Installation Process 9 Install the Remote Mount Board on the Motherboard A Make sure that the power to the chassis is still turned off, the power cords are unplugged, and the chassis is grounded and has no AC power. B Insert the remote mount board in a PCIe slot on the motherboard, as shown in the following figure. NOTE: Some PCIe slots support only PCIe graphics cards. If a remote mount board is installed in one of these slots, the remote mount board will not function. Refer to your computer documentation for information about the PCIe slot. C Press down gently, but firmly, to seat the board correctly in the slot. D Use the bracket screw to secure the remote mount board to the system chassis. 10 Mount the Super Capacitor Pack Module to the Intel Server Chassis NOTE: Most of the Intel Server Chassis provide a position to mount the Super Capacitor Pack module clip; the remote mount board is not needed in this kind of scenario. Refer to the Intel Server System User Guide for details of the position where the Super Capacitor Pack module clip can be mounted. A Ground yourself, and make sure that the system is grounded. B Place the Super Capacitor Pack module and the clip front-side-up on a flat, clean, static-free surface. C Press the Super Capacitor Pack module into the clip until the module clicks firmly into place, as shown in the following figure (for reference only; actual shape of the product may vary from the figure). Bracket Screw Press Here RMFBU4 module Super Capacitor Pack module C Press Here D Locate the mounting holes for the Super Capacitor Pack module clip in the Intel Server Chassis. Remote Mount Board E Align the tabs on the clip with the mounting holes in the Intel Server Chassis and slide the clip until the clip engages with the mounting holes. Edge of Motherboard PCIe Slot Intel RAID Controller RS3DC080 as shown E Fan Bulkhead E Reinstall the computer cover, and reattach the power cords. F Turn on the power to the computer. D Refer to the Intel RAID Software User Guide for information about running the RAID configuration utility and installing the software drivers. 5

General Installation Process 11 Connect the RMFBU4 Module to the Remote Super Capacitor Pack Module (Valid for Intel Server Chassis) 12 Reinstall the RAID Controller on the Motherboard (Valid for Intel Server Chassis) A Ground yourself, and make sure that the system is grounded. B Place the RAID controller on a flat, clean, static-free surface. C Remove the cable that is included in the RAID controller box. D Insert one 9-pin cable connector on the cable into the 9-pin J1 connector on the RMFBU4 module, as shown in the following figure (the cable is blue). E Insert the other 9-pin cable connector into the 9-pin connector on the remote Super Capacitor Pack module. Align the cable connectors to make sure that they are connected correctly. RMFBU4 module Intel RAID Controller RS3DC080 as shown A Make sure that the power to the chassis is still turned off, the power cords are unplugged, and the chassis is grounded and has no AC power. B Install the RAID controller in a PCIe slot on the motherboard, as shown in the following figure. NOTE: This RAID controller is a PCIe x8 card, and it can operate in x8 or x16 slots. Some PCIe slots, however, support only PCIe graphics cards; if a RAID controller is installed in one of these slots, the RAID controller will not function. Refer to the guide for your motherboard for information about the PCIe slot. C Press down gently, but firmly, to seat the card correctly in the slot. D Secure the RAID controller to the computer chassis with the bracket screw. Bracket Screw Intel RAID Controller RS3DC080 as shown J1 RMFBU module Press Here Press Here Edge of Motherboard PCIe Slot E Reinstall the computer cover, and reattach the power cords. F Turn on the power to the computer. Refer to the Intel RAID Software User Guide for information about running the RAID configuration utility and installing the software drivers. 6

Reference Documents If you need more information about any topic covered in this guide, refer to the following documentation on the Intel website at http://www.intel.com/support: Intel RAID Controller RS3DC040/RS3DC080 Quick Installation User's Guide 12Gb/s Intel RAID Controllers User Guide Intel RAID Software User Guide Software license agreement 7